Plans (9) M EC2021 -00437 Iwp MECHANICAL SYMBOL LIST GENERAL MECHANICAL NOTES RECEIVED INT N T E R F A C E NOTE: This is a standard symbol list and not all items listed may be used. JUN 17 1011 E N G I N E E R I N G A. THE INTENT OF THESE DRAWINGS IS TO PROVIDE A COMPLETE AND WORKABLE FACILITY WITH CITY OF TIGARG Abbreviations OBD OPPOSED BLADE DAMPER v ECCENTRIC TRANSITION, COMPLETE SYSTEMS AS SHOWN,SPECIFIED AND REQUIRED BY APPLICABLE CODES. INCLUDE ALL 3UILDINGDIVISION RECTANGULAR OR ROUND WORK SPECIFIED AND SHOWN ON THE ACCOMPANYING DRAWINGS, INCLUDING APPURTENANCES, A/C AIR CONDITION(ED) FLAT OVAL DUCT DROP OC ON CENTER ^ CONNECTIONS, ETC., IN THE FINISHED JOB. 100 SW Main Street OD OUTSIDE DIAMETER B. ALL WORK AND MATERIALS SHALL CONFORM TO THE LOCAL AND STATE CODES,AND ALL FEDERAL, Suite 1600 AD ACCESS DOOR STATE AND OTHER APPLICABLE LAWS AND REGULATIONS. Portland, OR 97204 PD PRESSURE DROP FLAT OVAL DUCT RISER T- 503.382.2266 C. CONTRACTOR RESPONSIBLE FOR OBTAINING AND PAYMENT FOR ALL PERMITS,LICENSES,AND www.interfareengineering.com AFF ABOVE FINISHED FLOOR INSPECTION CERTIFICATES REQUIRED IN ACCORDANCE WITH PROVISIONS OF CONTRACT DOCUMENTS. PH PHASE ,�,w� FLEX DUCT BOD BACKDRAFT DAMPER D. THESE PLANS ARE DIAGRAMMATIC IN NATURE,CONTRACTORS SHALL INCLUDE APPROPRIATE PRV PRESSURE REDUCING VALVE ALLOWANCES FOR OFFSETS AS REQUIRED TO ACCOMMODATE VERTICAL AND HORIZONTAL BFF BELOW FINISHED FLOOR PSI POUNDS PER SQUARE INCH FLEXIBLE CONNECTION VARIATIONS IN THE LOCATIONS AND ELEVATIONS OF DUCTWORK,PIPING AND OTHER EQUIPMENT. ` QED PROFESS E. MATERIALS AND EQUIPMENT SHALL BE NEW. WORK SHALL BE OF GOOD QUALITY,FREE OF FAULTS BFP BACKFLOW PREVENTER Ep y QTY QUANTITY NON-SYMMETRICAL WYE AND DEFECTS AND IN CONFORMANCE WITH THE CONTRACT DOCUMENTS. � 17430PE BHP BRAKE HORSEPOWER F. COORDINATE DEMOLITION,CUTTING, PATCHING,ETC,WITH EXISTING FIELD CONDITIONS. ALL NEW ORE GO R RISE OR EXISTING WORK CUT OR DAMAGED SHALL BE RESTORED TO ITS ORIGINAL CONDITION. CD CEILING DIFFUSER C� ;�� RECTANGULAR DUCT DROP 92 rFpi 28.1`3'�p RA RETURN AIR G. CONDITIONS SHOW ON THE PLANS RELATIVE TO THE WORK TO BE PERFORMED ARE BASED ON THE Oq W F CD CONDENSATE DRAIN RECTANGULAR DUCT RISER BEST INFORMATION AVAILABLE BUT ARE SUBJECT TO VERIFICATION. VERIFY LOCATIONS AND RET RETURN ELEVATIONS OF DUCTWORK AND UTILITIES TO BE CROSSED OR CONNECTED. EXPIRES. CONT. CONTINUATION y --�t�� RPM REVOLUTIONS PER MINUTE RECTANGULAR MAIN WITH H. PROVIDE CEILING ACCESS PANELS FOR COMPONENTS LOCATED ABOVE INACCESSIBLE CEILING COP COEFFICIENT OF PERFORMANCERECTANGULAR BRANCH SYSTEMS. MAINTAIN FIRE RATINGS WHERE REQUIRED. SA SUPPLY AIR I. SEALALL EXISTING AND NEW FIRE RATED PIPE AND DUCTWORK PENETRATIONS WITH UL LISTED AND CU CONDENSING UNIT RECTANGULAR MAIN WITH ROUND SEER SEASONAL ENERGY EFFICIENCY RATING BRANCH OFFICE COPY FICE FIRE MARSHALAPPROVED FIRE RETARDANT MATERIALS AND METHODS. OFY CV CHECK VALVE J. CONTRACTOR SHALL PROVIDE ALL MISCELLANEOUS STEEL AND COMPONENTS REQUIRED TO SUPPORT SF SQUARE FEET RECTANGULAR OFFSET LESS THAN DUCT,PIPE, MECHANICAL EQUIPMENT,AND ELECTRICAL/CONTROL PANELS RELATED TO MECHANICAL CW COLD WATER 15° EQUIPMENT. PROVIDE FLOOR SUPPORT COMPONENTS,HANGERS AND SEISMIC RESTRAINTS AS SH SENSIBLE HEAT REQUIRED. D DROP `� � RECTANGULAR OFFSET MORE THAN SOV SHUT OFF VALVE 15° DB DECIBEL SP STATIC PRESSURE ROUND DUCT DROP DB DRY BULB DIA DIAMETER T, TEMP TEMPERATURE ROUND DUCT RISER TD TEMPERATURE DIFFERENCE DX DIRECT EXPANSION TH TOTAL HEAT ROUND DUCT WITH ROUND BRANCH � EAT ENTERING AIR TEMPERATURE TP TOTAL PRESSURE p ROUND WYE EER ENERGY EFFICIENCY RATING EF EXHAUSTFAN V VOLT '' SYMMETRICAL WYE V♦ O W/ WITH Q O EFF EFFICIENT T J = ELECT ELECTRICAL W WATT General UEWT ENTERING WATER TEMPERATURE WB WET BULB —X—X— O DEMOLISH WC WATER COLUMN V♦ _ EXH EXHAUST O ` W EXISTING WORK � Q F FAHRENHEIT Dampers FD FIRE DAMPER I NEW WORK e i FIRE DAMPER FLA FULL LOAD AMPS FD FD 30X16 RECTANGULAR DUCT SIZING /n FT FEET FIRE/SMOKE DAMPER� Z v FS W 30"0 ROUND DUCT SIZING r GAL GALLONS �_ �, ,_ I MOTORIZED DAMPER Q „ �❑❑;—J„ N GPH GALLONS PER HOUR MD MD CONTINUATION W GPM GALLONS PER MINUTE SMOKE DAMPER SD SD X Q eDETAIL NUMBER AND SHEET LOCATION HD HEAD I VOLUME DAMPER X Z HP HORSEPOWER XX_X EQUIPMENT IDENTIFICATION OFFICE-COPY ■ W _ 0 LOON Crff OP TIGAIM, ' / HTG HEATING Diffusers and Grilles KEYED NOTE REVIEWED FOR CODE COMPLIANCE Ilp n w Q 00 HTR HEATER EXHAUST AIR Approved.\j�1J ® 0 POINT OF CONNECTION OTC. [ ] ' 1 3: 1' HWC HOT WATER COIL Permit V y " • Y) ]P1 tea ) -�� y�� ♦^ a Q RETURN AIR ID INSIDE DIAMETER A SECTION NUMBER AND SHEET LOCATION Addresa � 9� Orit A � W co 0 XXX Suite M. IE INVERT ELEVATION ® ® SUPPLY AIR By. = Date: IN INCHES 12x12 CD-1Piping Systems SHEET TITLE COVER SHEET - —RL REFRIGERANT LIQUID DIFFUSER OR GRILLE IDENTIFICATION THE ACTIVATION OF A DUCT 10o SMOKE DETECTOR SHALL KW KILOWATT MECHANICAL LAT LEAVING AIR TEMPERATURE Ductwork FittingsACTIVATEAVISIBLE AND —RS— REFRIGERANT SUCTION AUDIBLE SUPERVISORY LBS, POUNDS ACOUSTICALLY LINED DUCT(SIZES SIGNAL AT A CONSTANTLY LH LATENT HEAT SHOWN ARE NET INSIDE) —RHG— REFRIGERANT HOT GAS ATTENDED LOCATION ION REVISIONS MA MIXED AIR BELLMOUTH OMSC MAX MAXIMUM CONCENTRIC SQUARE TO ROUND SHEET INDEX MBH THOUSAND BTU'S PER HOUR MD MOTORIZED DAMPER CONCENTRIC TRANSITION, RECTANGULAR OR ROUND M1.0 COVER SHEET-MECHANICAL M1.1 SCHEDULES- MECHANICAL MIN MINIMUM DUCTWORK TO BE DEMOLISHED MD2.1 ROOF PLAN - DEMOLITION -MECHANICAL N/A NOT APPLICABLE DRAWN BY FLAT OVAL DUCT ELBOW M2.0 FLOOR PLAN -MECHANICAL JDCVALIDITY OF PERMIT NIC NOT IN CONTRACT M2.1 ROOF PLAN - MECHANICAL CHECKED BY NO. NUMBER JJ J MITERED ELBOW WITH TURNING M4.1 ENLARGED PLANS- MECHANICAL THE ISSUANCE OF A PERMIT Rick Siienzi VANES M4.2 ENLARGED PLANS- MECHANICAL BASED ON CONSTRUCTION JOB NO. NTS NOT TO SCALE DOCUMEDATA SHALL NOT PREVENT 2020-046)5 AND OTHER RADIUSED ELBOW M8.1 DETAILS -MECHANICAL OA OUTSIDE AIR =2 M8.2 PHOTO DETAILS-MECHANICAL THE CODE OFFICIAL FROM DATE REQUIRING THE CORRECTION OF ERRORS. OSSC 105.4 01/11/2021 SHEET NUMBER BID SET M1 .0 FILE: MID DURHAM.DWG - M1.0 EDIT: 1/11/2021 10:37 AM BY JONATHANC PLOT: 1/11/2021 3:04 PM BY JONATHAN COPE (E) AIR HANDLING UNIT SCHEDULE SUPPLY FAN COOLING COIL HEATING COIL MIX BOX DAMPER CFM RETURN FAN NEW ELECTRONIC CONTROL DEVICES P WATER CONTROL CONTROL MIN , INTERFACE ARRANGEMENT TOTAL CLG COND HTG FLOW VALVE VALVE DETAIL MIN MAX TOTAL OSA OSA RA MA EA HW REF REF SYMBOL AREA SERVED LOCATION TYPE CFM (MBH) STAGES UNIT (MBH) (GPM) SIZE TYPE REFERENCE CAD CAD RAD EAD CFM DMPR DMPR DMPR DMPR DMPR VLV LLV-t LLV-2 OTHER F NOTES E N G I N E E R I N G ASU-1 6 CLASSROOM POD MECHANICAL RM 200 1 6000 265 2 CU-1 94 6.3 1/2" 3-WAY 3/M8.1 810 5190 5190 5190 5190 1 1 1 0 1 1 1 1 1 ASU-2 KINDERGARTEN &ADM MECHANICAL RM 201 1 4485 190 2 CU-2 97.8 6.5 1/2" 2-WAY 3/M8.1 1035 3450 3450 3450 3450 1 1 1 1 0 1 1 1 1 1 ASU-3 INSTR. MAT. CENTER MECHANICAL RM 201 2 5400 170 2 CU-3 71.7 4.8 1/2" 2-WAY 4/M8.1 550 4850 4850 4850 4850 1 1 1 0 1 1 1 1 1 100 SW Main Street ASU-4 MULTIPURPOSE MECHANICAL RM 201 3 6075 - 105 7 1/2" 3-WAY 4/M8.1 960 5115 5115 - - 1 1 1 0 1 1 1 0 1, 2 Suite 1600 ASU-5 CLASROOM A MER-A 4 10000 260 2 ACCU-5 260 21 1" 2-WAY 3/M8.1 3330 10000 8000 2000/9000 - 1 1 1 0 1 1 0 0 1, 7 Portland, OR 97204 503.382.2266 ASU-6 CLASROOM B MER-B 4 9500 240 2 ACCU-6 260 21 1" 2-WAY 4/M8.1 3330 9500 7500 2000/9000 - 0 0 0 1 0 1 0 0 1, 7 www.interfaceengineedng.com ASU-7 STAGE/STORAGE MER-C 4 1300 33 1 ACCU-7 37 2.5 1/2" 2-WAY 4/M8.1 105 1300 1200 100/1300 - 0 1 0 1 2 1 0 0 1 ASU-8 CLASSROOM D MER-D 4 14000 360 2 ACCU-8 350 29 1" 2-WAY 3/M8.1 4260 14000 11500 2500/12800 - 1 1 1 0 2 1 10 0 1 1 ASU-9 KITCHEN MER-C 4 850 - 16 1.1 1/2" 2-WAY 4/M8.1 120 850 850 120/850 - 1 1 1 0 1 1 0 0 1 1 ��D PRop ASU-10 GYM MER-D 4 6650 240 16 1" 3-WAY 4/M8.1 1200 6650 5400 1250/6650 - 0 0 0 0 0 1 0 0 1, 4, 7tNDiNffq 1743OPE 0RtG0 NOTES: 1 REMOVE ALL REPLACED AND ABANDONED PNEUMATIC TUBING AND CONTROL DEVICES. W.F 2 EA DAMPER LOCATED IN ROOF HOOD IN CEILING OF THE MULTI-PURPOSE ROOM. 3 UNIT DAMPERS CONSIST OF A COIL FACE DAMPER; BYPASS DAMPER; TWO DUCT SUPPLY ZONE CONTROL DAMPERS MAX. OAD RF MAX. OAD ACCESS SECTION EXPIRES: 12131/21 MIN. CAD EAD AF MIN. OAD RAD ACCESS SECTION 4 EA DAMPERS LOCATED IN ROOF HOOD IN CEILING OF THE GYM. 5 PROVIDE NEW FREEZE STAT (LOW TEMPERATURE ALARM)SENSOR AFTER HEATING COIL. MIN. CAD 6 EA DAMPER LOCATE IN ROOF HOOD IN MECHANICAL ROOM. F F OAD CC � MB MB RF SF C SF C C � MB PLENUM < C CT MAX. CAD T �+D FUTURE-/ RAD FILTER/ TYPE 1 TYPE 2 TYPE 3 MIXING BOX TYPE 4 ASU ARRANGEMENT TYPES UNIT HEATER / HW COIL SCHEDULE (N) CONDENSING UNIT SCHEDULE ~ V SUPPLY FAN BASIS OF DESIGN AIR SOURCE CONDENSER ELECTRICAL CONTROL QTY EER APPROX. MAX TOTAL FAN CAP VALVE DETAIL NOM OF COMPRESSOR CAP AMBIENT OR DIMS WT , SYMBOL CFM RPM MHP (MBH) SIZE REFERENCE NOTES SYMBOL UNIT SERVED MFR MODEL TONS CIRCUITS TYPE (MBH) DB (°F) SEER VOLTS PH MCA MOCP (LxWxH) (LBS) NOTES CIO O CUH-1 200 900 1/30 20 1/2 2/M8.1 1, 2 ACU-1 ASU-1 CARRIER 38APDO25 25 2 SCROLL 265 95 208 3 121 150 1200 1, 3 CUH-2 400 1075 1/30 28 1/2 2/M8.1 1, 2 ACU-2 ASU-2 CARRIER 38AUDC16 15 2 SCROLL 190 95 208 3 60 80 750 1, 2 Q O CUH-3 1 200 900 1 1/30 20 1/2 2/M8.1 1, 2 ACU-3 ASU-3 CARRIER 38AUDC16 15 2 SCROLL 183 95 208 3 60 80 750 1, 2 UH-1 510 1550 1/20 23 1/2 1/M8.1 1, 2 ACU-5 ASU-5 CARRIER 38APDO25 25 2 SCROLL 300 95 208 3 121 150 1200 1, 3 UH-2 510 1550 1/20 23 1/2 1/M8.1 1, 2 ACU-6 ASU-6 CARRIER C 0 9 0 1 1 0 1200 1, 3 O V UH-3 510 1550 1/20 23 1/2 1/M8.1 1, 2 ACU-7 ASU-7 CARRIER 24A6B3548 4 1 SCROLL 36 95 208 3 17' 25 1 1, 4 ACU-8 ASU-8 CARRIER A 4 L 6 9 0 6 2 5 2200 1, 3 O V♦ CUH-1 136 1/30 11.4 1/2 1/M8.1 1, 2 i > Q Uj CUH-2 136 1130 11.4 1/2 1/M8.1 1, 2 NOTES: 1. PROVIDE WITH SINGLE POINT CONNECTION CUH-3 1 136 1130 11.5 1/2 1/M8.1 1, 2 2. PROVI E HOT '':::I BYP S F R CAPACI CONT OL. UH-1 280 1/25 1.5 1/2 1/M8.1 1, 2 3. PROVIDE HOT GAS BYPASS OR ONE DIGITAL COMPRESSOR FOR CAPACITY CONTROL. 1 /A UH-2 280 1/25 1.5 1/2 1/M8.1 1, 2 4. PROVIDE TWO STAGE COMPRESSOR FOR CAPACITY CONTROL. U♦ UH-3 280 1/25 1.5 1/2 1/M8.1 1, 2 UH-4 280 1/25 1.5 1/2 1/M8.1 1, 2 2 UH-5 280 1/25 1.5 1/2 1/M8.1 1, 2 W = UH-6 280 1/25 1.5 1/2 1/M8.1 1, 2 (N) DX COOLING COIL SCHEDULE I. COIL DATA COOLING DATA 2 NOTES: 1. UNIT SIZED FOR 20OF EWT; 170F LWT AIR AIR MAX TOTAL SENS W J Q N 2. PNEUMATIC VALVE ACTUATOR TO BE REPLACED WITH NEW ELECTRIC ACTUATOR. HANDLER FLOW WIDTH HEIGHT # APD CAP CAP EDB EWB LDB LWB CONDENSING PROVIDE ALLOWANCE FOR FULL REPLACEMENT OF 6 VALV�VALVES. IS EQUIPMENT. 1 TAG REFRIGERANT (CFM) (IN) (IN) ROWS (IN H2O) (MBH) (MBH) (°F) (°F) (°F) (°F) CIRCUITING UNIT NOTES D W V Q 0 BASE BID ASU-1 R-41 OA 6000 65 38 6 0.8 199 250 84 66.6 52.4 52 SINGLE ACU-1 PROVIDE UNIT PRICE FOR FULL REPLACEMENT OF ADDITIO ASU-2 R-41 OA 4485 65 33 6 0.8 186 148 85 67 53.5 52.6 SINGLE ACU-2 ASU-3 R-41 OA 5400 65 38 4 0.6 169 144 76.8 62.2 51.8 50.7 SINGLE ACU-3 OQQ CD � aWc ASU-5 R-41 OA 10000 72 46 5 0.42 294 255 79 64 54.9 53.7 DUAL ACU-5 ASU-6 R-41 OA 9500 72 46 4 0.42 279 240 79 64 55.2 53.7 DUAL ACU-6 i' 0 ASU-7 R-41 OA 1300 31 24 5 0.35 42 33 76 62 51.9 51.2 SINGLE ACU-7 ASU-8 R-41 OA 14000 91 51 5 0.63 444 361 78 64 55 54 DUAL ACU-8 NOTES: co 0_ SHEET TITLE (E) CONTROL DAMPER SCHEDULE SCHEDULES - MECHANICAL AIR DAMPER SIZE HANDLER MIN OSA OSA RETURN RELIEF EXHAUST OTHER TAG DAMPER DAMPER DAMPER DAMPER DAMPER DAMPER NOTES (E)ASU-1 4x55 10x55 14x55 12x55 - (E)ASU-2 4x40 10x40 14x40 1440 - (E)ASU-3 4x55 8x55 12x55 12x55 - REVISIONS (E)ASU-4 8x55 12x55 20x55 44x44 - 1 1 ADDENDUM 1 2/2/2021 (E)ASU-5 - 22x55 22x50 24x36 (E)ASU-6 - 22x55 22x50 24x36 - (E)ASU-7 - 12x24 18x16 16x10 - (E)ASU-8 - 24x36 2436 2436 - (E)ASU-9 - 24x12 14x10 14x10 - (E)ASU-10 - 16x46 16x46 16x32 - EF-6 2 EF-8 DRAWN BY NOTES: 1. REMOTE RELIEF DAMPER JDC 2. DAMPER IN DUCT LINKED TO ASU OPERATION CHECKED BY Rick Silenzi JOB NO. 2020-0465 DATE 01/11/2021 SHEET NUMBER BID SET miA FILE: M11 DURHAM.DWG - M1.1 EDIT: 2/1/2021 10:42 PM BY RICKSI I PLOT: 2/1/2021 10:43 PM BY RICK SILENZI O SHEET KEYNOTES @fp 1 CONDENSING UNIT TO BE DEMOLISHED. REMOVE ALL I N T E R F A C E EQUIPMENT SUPPORTS AND ANCHORS. REMOVE ALL E N G I N E E R I N G INTERIOR AND EXTERIOR REFRIGERANT PIPING, COMPONENTS AND SUPPORTS BACK TO THE AIR HANDLER COIL. ROOF CURBS TO BE LEFT IN PLACE FOR RE-USE. 2 ROOFTOP UNIT TO REMAIN. 100 SW Main Street Suite 1600 Portland, OR 97204 Tc:_ 503.382.2266 www.interfaceengineering.com CY� �� ED PROre �� INf£� Dov D D-E D D-C D-B -A 1 f j ¢ 17430PE i OREG0 .1 9? 29, V __._— _ I I i I I I - I _I I_ - I- - - I �R � EXPIRES 12/31121 I I I I I I I I I I I I I I I i, AREA 1 ' I t— 'r -- -- D-2 D-2 I 1 ACU-1 rx MECHANICAL ROOM ASU-5 _ _ - I L_x_ I i i I I I I ♦♦�♦♦ MECHANICAL AREA 13 V ROOM ASU- 1 • _ -------, SEC I — 3 � D-3 I I AREA 3 _ I � I o� I p 0 ACU-5 AREA 8 I EA s 2 Il O V f I U W (Ej SKYLIGHT 4 I - Z -A.1 -A.1 -A.1 A. DPWtL.Lj CL` I BSC + AREA 91 I _ _ I D-7 _ - - _ — - _ - 40 - - - - - - - -- - - - - - - - - - - - Q � � ! N D-8 AREA 4 — W p I I I Q J -8. - __ - .�_� _ - _ I .. AREA1t*— -- - - - -- - - — - - -- - AREA 21 -- - -- - - --- - - W v_ m Z MECHANICAL �, M AS r I ACU-6 1 A A 0 _ ROO - — -- 1 ACU-2 _ I I I _ LU f-'Sc AREA 16 I — - - - - - - - - - - -- _. LU I 1 ACU-3 - ----- - ------- AR�q 22 V y iY -- - — --_ _ LE7 — — — — -- — — — — --� — MEC ICAL MECHANICAL I 1� -1 �— — — — ASU-9, MAU7 ROOM ASU 8, 1, - - - -1 ASU-10 SHEET TITLE -- — — -- — - -- -- — — - MECHANICAL I - ---- -- -- — — _ _ __ _ _ _ _ AEA 11 ROOM ASU- _ i I ROOM ASU2, AREA 17 ASU-3,ASU-4 I ( I AREA 24 I ROOF PLAN - it DEMOLITION - 1 MECHANICAL UU L--------t-------- --- - -- - - ----- ----------------------- --------- ------ II ARI� —23 x 1 — -- '=` -- — xrx�-x REVISIONS — — �------ -- — — — — — ZZ AREA 16a ; 1 ACU-8 _ ------ - -- - -- -- -- -- ---I I- AREA 191 , 14. -14. - - - - � - - - - - -- - - -- - - � - - --- - - - � - - I I I I I I I i I I I I it IDRAWN BY 14. - - - - -- - -- ----- - — -- - - - - - __-._ _ - _ __- . _ _ _ _ g_ _ __ ___ __. _ -- _ --- - JDC i CHECKED BY Rick Slienzi J08 NO. •L. -L. L. L D-L D-K D-J D-H -ti D-F D-E D-D D-C D-B A.1 D-A -A.1 -A.7 A.16 C-A.1 A.1 A.1 2020-0465 DATE 1 ROOF PLAN - DEMOLITION - MECHANICAL 01/11/2021 SyAOZ SHEET 0 8' 16' 32' SCALE: 1/16"=1'-0" M D2. 1 BID SET FILE: MD21 DURHAM.DWG — MD2.1 I EDIT: 12/22/2020 6:15 PM BY RICKSI I PLOT: 1/11/2021 3:05 PM BY JONATHAN COPE O SHEET KEYNOTES =i 1. ASU-10 FAN COIL ABOVE THE CEILING TO HAVE THE HW W e CONTROL VALVE REPLACED. SEE MECHANICAL SCHEDULES FOR ADDITIONAL DETAIL, INTERFACE 2. BUILDING CONTROL PANELS LOCATED IN THE JANITOR E N G I N E E R I N G ROOM. 3. NOT USED. 4. REPLACE EXISTING PNEUMATIC VALVE ACTUATOR ON HEATING VALVE WITH NEW ELECTRONIC ACTUATOR. 100 SW Main Street REPLACE EXISTING PNEUMATIC SENSOR WITH NEW DIGITAL Suite 1600 SENSOR. SEE SCHEDULES FOR DETAILS. Portland, OR 97204 503.382.2266 5. EXISTING PNEUMATIC DAMPER ACTUATOR TO BE REPLACED www.interfar-eengineedng.com WITH ELECTRONIC ACTUATOR. ED PROF D D-K Del D-H D-G D D D-D D-C D-B -A.1 �tR FSS /0Z R T 17430P OREGON -- ----- I — -- -- — -- -- — -- — I , I I EXPIRES 12'31!2 CLASSROOM ( CLASSROOM I CLASSROOM CLASSROOM I CLAS ROOM CLASSROOM 10 I 4 CUH-1A 8 - - - - C- �_ ---1 WORK RM W ORK RM - 52 CLASSROOM LASSROOM 12 CLASSROOM . i B G I 1 4 STAFF ROOM M4.1 IUM 61 ABOVE -� :�. ATR( 4 CUH-1B �M STAFF ROOM CLASSROOM O ABOVE I 50 ( 3 J (CLASSROOM CLASSROOM D.S ----- -_ _ ___ _ -- --- _- - -t- -- - ----+ - ----+- - -------- i - -- ------- - __ ------ I _ p-5 O W -- 1 = > � LIBRARY WORKI2001STp OI *11L066 LTH RM, C1 77 110 t' CONF_RM 0103 D-G RECEPTION/,pDIMIN - -- C102 - - _� V -i NCIP ATRIU STAFFLUNG P�C104AL Z a 1 C1 W I M4.2 i D-T +-- - - Lll { - - - - -- - - - - - ---- - -- - -- - - -_- - - - --- - - - - Q -_ - CLASSROOM---- -I i -- ABOVE -- I - --- - - -- -- i - � I I I I I I � ( CV D-8 —. WORK I ". W J O N 15 54G -8. - - - - { -{ - - - - - - city - 1080 - - - uH- - --- - -- - ----- - -- -- - - _ Qo -8. CLASSROOM W -his_ ORK SPEECH COON UNSEL( G 14 C 2 �I a s- GYM ENTRY -- ae - - - .-- - - - - Q I _ .. o0 _ -- - - C109- -- OFFICE - -- -- - - D-9 -_�___-_-J -__B CLASSROOM - --- - ! 30 O -9 I - CLAS8 I I I 4 CUH-3B I I G Ii V N lam/ 13 c' Uj -9. -r - �,4 - t pFt - ----t — - - - - - - - - - M - -- - - - - - - - - - = G 19 __ - -- _ .____. _. _________rt - ._- __:7 _-. _ ------ KITCHEN -1 -� CAFETERIA = CLASSROOM CLASSROOM - GYM 22 _ — -- Fi —._.27 I I I - - 8 SHEET TITLE ICLASROOM I ROOM 2 OFFICE FLOOR PLAN - -- __ - - -_____._--.__-_M4.1 _ -------__- -- --- M4.21S r - MECHANICAL ABOVE ABOVE h I ABOV - - WORK RNICLASSROOM WORKRM4 CUH-3A 5_AR 20 21 ----- - - - -- - - - - - - -- -=- _ - - - - -- - --- - - - u STOR. G I REVISIONS I STORAGE I CLASSROOM CLASSROOM I I -�� -- 2- 23 6 - - _ - J -F.•14 - _w I - I I I l _____ I�_ -- E I CLASSROOM CLASSROOM - - -- -- - - --25 24 — - - - - 7-77-7 DRAWN BY.14. _ -------- -14. J----T" -- --�— - - -- - - - -- ----- --- - — - - - - — -- - -- - I --- — — - - - - -- - - - i - - JDc CHECKED BY Rick Silenzi JOB NO. oD- 6DH D-G D-F DOE )D D-C 6DB -A.1 D-A -A.1 -A.1 -A.1 -A.1 -A.1 -A.1 -A.2 2020-0465 DATE 1 FLOOR PLAN - MECHANICAL 01/11/2021 s-1aoz 0 8' 16' 32' SHEET NUMBER SCALE: 1/16"=1'-0" M2 ,0 2 .O BID SET FILE: M20 DURHAM.DWG - M2.0 EDIT- 12/20/2020 3:22 PM BY JONATHANC PLOT: 1/11/2021 3:05 PM BY JONATHAN COPE Ed P INTERFACE E N G I N E E R I N G O SHEET KEYNOTES 1. NEW CONDENSING UNIT- SEE MECHANICAL SCHEDULE FOR DETAILS. INSTALL NEW REFRIGERANT PIPING AND SUPPORTS TO AIR HANDLER COIL PER DETAIL 6/M8.1. 100 SW Main Street PROVIDE ANCHORING AND SUPPLEMENTAL STEEL Suite 1600 SUPPORTS PER DETAIL 7/M8.1. Portland, OR 97204 503.382.2266 2. ROOFTOP UNIT TO REMAIN. www.interfaceengineering.00m -L. L D•L D-K D-J D-H D-G D D-E D-D D-C D-B -A.1aG I N f css 17430PE/f ORO 1 9 sF2 81 u L­4f W w.Ftp D-1 EXPIRES: 12/31/21 - I li ---- - - - AREA 1 I ' �- D-2 I FT I I 1 ACU-1 I I MECHANICAL ROOM ASU-5 MECHANICAL I ,�♦ ROOM ASU-1 AREA 13 V oBE OBEL AREA 3 p-4 - -- P - - - - -- - O o �ll Q 10 ACU-5BEtb AREA 8 Ilrr EA6 2 I O v -- ----------- W (E)SKV'LIC3HT I � A/ co - �- I � -- ---- .-__ __-,___. i i r-- -�_______ _____________ C-A -A.1 -A.1 �A� -A.1 Q-A� -A.1 -A. Z Z_ V e I ! 1.�. AREA 9 W i I _— I I p-� _..-,.a ,a. .��a — ._ --_.a_ - ___ __.r._. _ � ._ _--- __ 40 . N D4 -_ AREA 4 I I i W - — 1� — _ _ - - XAO - C3 04 - — — — — - JQ ~_ QMECHANICAL � �ROOM ASU-6 ACU-6 1 1 ACU-2 ZAREA 16 AREA 21 I I I _ 0 Q w � I Q = � Uio I ACU-3 9, - � AR 22 Q _/ Uj •� E - 1 _. - I - - 1.. k # _ _ } - --- -- -- - --- - - -- -- - - - --- - _ MECHANICAL - - ` co o MECHANICALROOM I i— ( r o •1 — AEA 11 ASU-7,ASU-9, MAU-1 RSOMASU-8,U_8, (BELOW) A —_ SHEET TITLE ---(BELOW) MECHANICAL AREA 17 ROOF P LAN � su 4ROOM ASU-2AREA24 MECHANICAL BEow) - - — -- — - - -------- -- I i I II i AR23 REVISIONS AREA 18a 1 ACU-8 I � �J - - --�- - 7 T - � - -T— - - -- --- - - - - - - - -- - -- - --- - — - - _- _ _. I AREA -- - - - - - — ACU 7 1 DRAWN BY r JDC T— — -- � — - i � --- I I I --- — — --- — --- — —. ____i CHECKED BY ANKO 11b -L. L D-L D IK D-J D-H D-G D-F D-E D-D D-C D-B -A.1 D-A -A 1 -A.1 �.1 -A J1 -A.1 -A.1 -A. JOB NO. 2020-0465 DATE 1 ROOF PLAN - MECHANICAL 01/11/2021 S AOZ 0 8' 16' 32' SHEET NUMBER SCALE: 1/16"=1'-O" M2 , 1 2 ■ 1 BID SET t FILE: M21 DURHAM.DWG - M2.1 EDIT: 12/22/2020 6:13 PM BY RICKSI I PLOT: 1/11/2021 3:05 PM BY JONATHAN COPE D-F D-E D-D O SHEET KEYNOTES � INTERFACE 1. GENERAL SCOPE OF WORK IN THE MECHANICAL ROOM INCLUDES BUT IS E N G I N E E R I N G NOT LIMITED TO THE FOLLOWING: THE REMOVAL OF ALL PNEUMATIC CONTROLS, TUBING, CONTROL PANELS,ABANDONED CONDUITS AND PATHWAYS. PATCH ANY HOLES OR OPENINGS IN THE MECHANICAL UNITS, DUCTWORK AND WALLS LEFT BY DEVICE REMOVAL. D-� – – 2. GENERAL SCOPE OF WORK FOR AIR HANDLING UNITS INCLUDES BUT IS r I I NOT LIMITED TO THE FOLLOWING: 100 SW Main Street A. REPLACE ALL PNEUMATIC DAMPER ACTUATORS FOR OSA, RELIEF, Suite 1600 EXHAUST AND MIXING WITH NEW ELECTRONIC ACTUATORS. Portland, OR 97204 B. REPLACE ALL REFRIGERANT PIPING, COMPONENTS, VALVES AND RELATED 503.382.2266 REFRIGERANT DEVICES WITH NEW. www.interfaceengineering.com ( I C. REPLACE PNEUMATIC HEATING WATER VALVE ACTUATOR WITH NEW ELECTRONIC ACTUATOR. D. REMOVE EXISTING R-22 DX COIL AND REPLACE WITH NEW R410A DX COIL. SEE SCHEDULE FOR SIZE AND FIELD VERIFY COIL DIMENSIONS PRIOR TO - ■ – – – – – – – – SUBMITTAL. .srvD PROs fS E. SEE MECHANICAL SCHEDULES FOR DETAILS. 4�\y1 �aDl NFt9`Si0� I 3. PNEUMATIC ACTUATOR TO BE REPLACED ON THE 3-WAY, 4" HEATING 1743 OPE VALVE WITH A NEW ELECTRONIC ACTUATOR AND TIED INTO 17 43 THE EXISTING CONTROL SYSTEM. 0REG0 4. REPLACE EXISTING PNEUMATIC VALVE ACTUATOR ON HEATING VALVE WITH NEW ELECTRONIC ACTUATOR. REPLACE EXISTING PNEUMATIC RELV w SENSOR WITH NEW DIGITAL SENSOR. SEE SCHEDULES FOR DETAILS, EXPIRES: 12/31/21 5. GENERAL SCOPE OF WORK FOR AIR HANDLING UNITS INCLUDES BUT IS -�■ – – _ – – NOT LIMITED TO THE FOLLOWING: i – A. REPLACE ALL PNEUMATIC DAMPER ACTUATORS WITH NEW ELECTRONIC ACTUATORS. B. REPLACE PNEUMATIC HEATING WATER VALVE ACTUATOR WITH NEW ELECTRONIC ACTUATOR AND CONNECT TO THE CONTROL SYSTEM. C. SEE MECHANICAL SCHEDULES FOR DETAILS. 6. NEW REFRIGERANT PIPING SIZED PER MANUFACTURERS CRITERIA FOR UNIT SIZE AND TO MAINTAIN OIL RETURN. FOLLOW EXISTING ROUTING RS AND MAINTAIN PENETRATIONS THROUGH THE WALL. SEE DETAIL 9.M8.1 FOR SUPPORT DETAIL. RHG L 7. REMOVE EXISTING PNEUMATIC CONTROL DAMPER ACTUATORS IN DUCT AND AND REPLACE WITH NEW ELECTRONIC ACTUATOR. I 8. FIRE/SMOKE PNEUMATIC DAMPER ACTUATORS TO BE REPLACED WITH NEW ELECTRONIC ACTUATORS. SEE PLAN AND SCHEDULES FOR NUMBER OF ZONES. ASU-2 �- 9. PE SWITCH TO BE REMOVED AND EQUIPMENT TO OPERATE O t ' -11 2 DIRECTLY FROM DIGITAL CONTROLS. CONTROL GENERAL NOTES ~ J D-F D-E ASU 4 p OA. WHERE EXISTING PNEUMATIC DEVICES ARE REMOVED, REMOVE ALL Q O ASSOCIATED PNEUMATIC PIPING AND CONTROLS. CONNECT NEW = ACTUATOR/DDC DEVICES TO EXISTING JCI SYSTEM CONTROL PANEL. ALTER PROGRAMMING AS REQUIRED FOR THE NEW DIGITAL DEVICE. B. CONFIRM DAMPER AND VALVE SIZES PRIOR TO SUBMITTAL. APPROX O (D-2 } `'" ""` DAMPER SIZES ARE SHOWN ON SCHEDULE. O v/♦^ C. PATCH WALL WHERE PNEUMATIC DEVICES ARE REMOVED FROM FINSIHED W i ROOM/WALL. 0 — N ._. _. -_ -_ _______ _ .__ D. CONTRACTOR TO FIELD VERIFY LOCATION OF ALL EQUIPMENT, CONTROL �■/ PANELS AND DEVICES TO ENSURE ALL SYSTEMS ON PNEUMATIC a CONTROLS ARE UPGRADED TO DIGITAL CONTROLS. Z Z (� OB (2) FSD'S ASU-3 w WONEW REFRIGERANT FIELD VERIFY LOCATION2 PIPINGTOACU-1 J ON ROOF. SEE M2.1 FOR CONTINUATION RS RL ( ■ EF-2 9 ti RHG -L. D-L W V m z Q Q CCD MZ MUj ONEW REFRIGERANT Q Q PIPING TO ACU-2 O I 0 RS 6/ ON ROOF. SEE M2.1 ASU-1 I RHG RL FOR CONTINUATION r Q V – V ' O ' 44 UH-2 I I OASU-5 Co + REF-A EXHAUST FAN Q - VERIFY LOCATION SHEET TITLE ENLARGED PLANS I i ' 4 UH-3 � ' NEW REFRIGERANT MECHANICAL PIPING TO ACU-3 O UH-1 I ON / FOR CONTINUATIONOF. E .1 M2 i HWB-1 I � O I REVISIONS 9 EF-1 ASU-5 2 D-3 O J &2)FSD'S I ❑� FIELD VERIFY LOCATION D-3 NEW REFRIGERANT OPIPING TO ACU-5 DRAWN BY HWP-2 HWP-1 I ON ROOF. SEE M2.1 FOR CONTINUATION JDC CHECKED BY Rick Silenzi ASU-1 ASU-2, ASU-3, ASU-4 ASU-5 JOB NO. 1 MECHANICAL ROOM PLAN 2 MECHANICAL ROOM PLAN 3 MECHANICAL ROOM PLAN 2020-0465 DATE 0 2' 4' 8' 0 2' 4' e' 0 2' 4' 8' 01/11/2021 SHEET NUMBER SCALE: 1/4"=I'-O" SCALE: 1/4"=l'-O" SCALE: 1/4"=l'-O" BID SET M4. 1 FILE: M41 DURHAM.DWG — M4.1 EDIT: 1/7/2021 9:39 AM BY JONATHANC I PLOT: 1/11/2021 3:05 PM BY JONATHAN COPE -A.1 -A.1 O SHEET KEYNOTES INTERFACE I 1. GENERAL SCOPE OF WORK IN THE MECHANICAL ROOM INCLUDES BUT IS E N G I N E E R I N G Q4 NOT LIMITED TO THE FOLLOWING: THE REMOVAL OF ALL PNEUMATIC -A D-A .1 D CONTROLS,TUBING, CONTROL PANELS, ABANDONED CONDUITS AND PATHWAYS. PATCH ANY HOLES OR OPENINGS IN THE MECHANICAL UNITS, DUCTWORK AND WALLS LEFT BY DEVICE REMOVAL. II I 2. GENERAL SCOPE OF WORK FOR AIR HANDLING UNITS INCLUDES BUT IS 100 SW Main Street NOT LIMITED TO THE FOLLOWING: Suite 1600 D-9 A. REPLACE ALL PNEUMATIC DAMPER ACTUATORS FOR OSA, RELIEF, Portland, OR 97204 I EXHAUST AND MIXING WITH NEW ELECTRONIC ACTUATORS. 503.382.2266 B. REPLACE ALL REFRIGERANT PIPING, COMPONENTS, VALVES AND RELATED \ REFRIGERANT DEVICES WITH NEW. www.interfaceengineering.00m -9 / - - -- - -- — -- C. REPLACE PNEUMATIC HEATING WATER VALVE ACTUATOR WITH NEW UH-5 4 ELECTRONIC ACTUATOR. D. REMOVE EXISTING R-22 DX COIL AND REPLACE WITH NEW R-410A DX COIL. I SEE SCHEDULE FOR SIZE AND FIELD VERIFY COIL DIMENSIONS PRIOR TO R lE Ep PRO!E SS ASU-10 SUBMITTAL. E. SEE MECHANICAL SCHEDULES FOR DETAILS. aGINEE i0 3. NOT USED. 17430PE j 4. REPLACE EXISTING PNEUMATIC VALVE ACTUATOR ON HEATING VALVE OREGO WITH NEW ELECTRONIC ACTUATOR. REPLACE EXISTING PNEUMATIC r n ( ; SENSOR WITH NEW DIGITAL SENSOR, SEE SCHEDULES FOR DETAILS. 92 r 2a,iy9 I �Rfw w. Q 5. GENERAL SCOPE OF WORK FOR AIR HANDLING UNITS INCLUDES BUT IS UHC III -9. — NOT LIMITED TO THE FOLLOWING: EXPIRES: 12/31/21 A. REPLACE ALL PNEUMATIC DAMPER ACTUATORS WITH NEW ELECTRONIC qO i B. REPLACE PNEUMATIC HEATING WATER VALVE ACTUATOR WITH NEW ELECTRONIC ACTUATOR AND CONNECT TO THE CONTROL SYSTEM. :M91 C. SEE MECHANICAL SCHEDULES FOR DETAILS. 6. NEW REFRIGERANT PIPING SIZED PER MANUFACTURERS CRITERIA FOR UNIT SIZE AND TO MAINTAIN OIL RETURN. FOLLOW EXISTING ROUTING AND MAINTAIN PENETRATIONS THROUGH THE WALL. SEE DETAIL 9.M8.1 FOR SUPPORT DETAIL. 7, REMOVE EXISTING PNEUMATIC CONTROL DAMPER ACTUATORS IN DUCT AND AND REPLACE WITH NEW ELECTRONIC ACTUATOR. 8. FIRE/SMOKE PNEUMATIC DAMPER ACTUATORS TO BE REPLACED WITH NEW ELECTRONIC ACTUATORS. SEE PLAN AND SCHEDULES ( i I FOR NUMBER OF ZONES. 9. PE SWITCH TO BE REMOVED AND EQUIPMENT TO OPERATE DI RF-10 DIRECTLY FROM DIGITAL CONTROLS. I I V CONTROL GENERAL NOTES j 0 i I A. WHERE EXISTING PNEUMATIC DEVICES ARE REMOVED, REMOVE ALL Q O UH-6 4 ASSOCIATED PNEUMATIC PIPING AND CONTROLS. CONNECT NEW ACTUATOR/DDC DEVICES TO EXISTING JCI SYSTEM CONTROL PANEL. J ALTER PROGRAMMING AS REQUIRED FOR THE NEW DIGITAL DEVICE. O ' MAU-1 B. CONFIRM DAMPER AND VALVE SIZES PRIOR TO SUBMITTAL.APPROX O DAMPER SIZES ARE SHOWN ON SCHEDULE. V� RF-9 ASU-9 -12 -- - - - - - - - _ - _ 0 C. PATCH WALL WHERE PNEUMATIC DEVICES ARE REMOVED FROM FINSIHED Uj D-L I O I ROOM/WALL. D. CONTRACTOR TO FIELD VERIFY LOCATION OF ALL EQUIPMENT, CONTROL I_ PANELS AND DEVICES TO ENSURE ALL SYSTEMS ON PNEUMATIC v, -12 — _ —� -- CONTROLS ARE UPGRADED TO DIGITAL CONTROLS. z FEE ''^^ -12. - - - - - - - - - - - HWa - - Q N I -- J LU J c n J Q � CY) ------------ - -------- I � 1 ♦ ♦ m Z 2 H Ii1 ��/ Q 0 �s 4 UH-2 I I Z x W NEW OQQ roc PPNGTOACUBNT D 0 ASU-6 ASU-7 2 ON ROOF. SEE M2.1 " I I FOR CONTINUATION � d RS 1 (A w RL RHG W 100 1 NEW REFRIGERANT 4 UH-3 -1 Q ti PIPING TO ACUS ON ROOF. SEE M2.1 SHEET TITLE FOR CONTINUATION ENLARGED PLANS O6 RF-7 C7 O9 ASU-6 REF-B EXHAUST FAN i -1 3 —___ __ __ _ _ —— — __ I — I I - MECHANICAL VERIFY LOCATION V J J � ASU-8 REVISIONS - -- - - -- - ----- O RF-8 -14 - - - - - --- -- - - I -�• — — — — — — — —NEW REFRIGERANT -_ _- DRAWN BY PIPING TO ACU-7 O6 I I JDC I I ON ROOF. SEE M2.1 CHECKED BY FOR CONTINUATION Rick Silenzi _ — — JOB NO. 2020-0465 ASU-6 ASU-7, ASU-9, MAU-1 ASU-8, ASU-10 DATE 01/11/2021 1 MECHANICAL ROOM PLAN 2 MECHANICAL ROOM PLAN 3 MECHANICAL ROOM PLAN SHEET NUMBER 0 2' 4' 8' 0 2' 4' 8' 0 2' 4' 8' INIIIIIIIIIIIIIIIIIIIIIIIIIEW SCALE: 1/4"=1'-0" SCALE: 1/4"=1'-0" SCALE: 1/4"=1'-0" BID SET . FILE: M42 DURHAM.DWG — M4.2 EDIT: 1/7/2021 9:41 AM BY JONATHANC I PLOT: 1/11/2021 3:05 PM BY JONATHAN COPE S� INTERFACE E N G I N E E R I N G 'j' ACCU BOLT ACCU UNIT TO ISOLATOR I AS SPECIFIED BY MANUFACTURER. HWS HWS SPRING ISOLATORS 100 SW Main Street —HWR---- —HWR 1 - -j 1/2"THICK GALVANIZED Suite 1600 ----- TT ---- --- — / (2.5"PR MIN. DEFLECTION Portland, OR 97204 J// �L 503.382.2266 AV SNUBBERS AS REQUIRED) STEEL PLATE �y.interfaceengineedng.com EXISTING PIPING EXISTING PIPING 14 _------ ___ EXISTINGROOF CURB AV E .D PROr ROOF \h` �aGtNEFAS/O' EXISTING PNEUMATIC J `L iI� CONTROL VALVE M 174�30P,E7�/J ACTUATOR TO BE I EXISTING PNEUMATIC OREGO" " REPLACED AIR CONTROL VALVE 9,y sEai 28.1ya° ACTUATOR TO BE W f — FLOW REPLACED f EXISTING UNIT C I DV XPII?i t . SECURE SPRING ISOLATOR DV HEATER EXISTING COIL TO CURB W/ANCHOR BOLT NOTE: PROVIDE SUPPLEMENTAL STEEL SUPPORTS SINGLE COIL TWO WAY MOTORIZED VALVE ACROSS EXISTING CURBS AS NEEDED FOR UNIT SUPPORT. 4 COIL PIPING DIAGRAM 7 ACCU MOUNTING DETAIL 1 HOT WATER UNIT HEATER DETAIL NO SCALE NO SCALE NO SCALE ♦r V HWS GALV'D STEEL CAP AND RAIN HOOD, HWS —HWR -- SECURED TO FLASHING WITH SCREWS 3"O.C., DRILL HOLES IN SIDE UNDER �----- HWR----,--- — —� HOOD TO SUIT PIPING EXISTING PIPING O M EXISTING PIPING O GALV'D STEEL FLASHING, NAIL 3"O.C. � T EXISTING PNEUMATIC i CONTROL VALVE REFRIGERANT PIPING AND ELECTRICAL U AV I ACTUATOR TO BE ��n 1 O ♦/ REPLACED AV ROOF O U) V♦CONDUIT(PIPE INSULATION NOT SHOWN) � > Q - I�-- ---� I W AIR FLOW L-4I � r z U Lryi AIR U I FLOW Q CM EXISTING COIL ___wEXISTING PNEUMATIC C I DV DV CONTROL VALVE L- a ACTUATOR TO BE EXISTING COIL r W REPLACED SINGLE COIL THREE WAY MOTORIZED VALVE J N BHC, CUH HEATING COIL TWO WAY MOTORIZED VALVE Uj PIPING DIAGRAM 5 COIL PIPING DIAGRAM J Q Z 2COIL G G � WV = 0 NO SCALE NO SCALE Z � W 8 PIPING AND CONDUIT ROOF PENETRATIONQ Q 00 NO CALE M-PIPE 6-10 N t 1 Q ii V N w (� = W CD FIRST STAGE � Q � � SIGHT GLASS ti LIQUID LINE HWS SOLENOID VALVE SHEET TITLE -----T ----HWR-----------� RLLHT GAS BYPASS PIPE CLAMP MECHANICALDETA CONTROLJJ NTROL VALVE EXISTING PIPING ------ - HOT GAS-� TEMPERED REF. PIPE M -`�--RS- -- - INSULATION W/EXTERIOR JACKET DX COOLING COIL I PURGE I SADDLE EXISTING PNEUMATIC CONTROL VALVE I I ACCU STRUT INTEGRAL TO ROOF SUPPORT REVISIONS ACTUATOR TO BE REPLACED I DRIER 6" MAX J L---- - V LIQUID LINE SOLENOID VALVE �I SIGHT GLASS HOT GAS BYPASS SOLENOID VALVE AIR SECOND STAGE MIN. 3-1/2" RECTOR SEAL, ROOF BLOX FLOW MECHANICAL ROOM ROOF MIRRO BLOCK OR EQUAL. ROOF MOUNTED PIPE C I DV GENERAL NOTES: SUPPORT SIZED FOR 5 PSI EXISTING COIL 1. TRAP&PITCH PIPING AS REQUIRED FOR ACTUAL RELATIVE LOAD MAX. DRAWN BY LOCATION OF COMPRESSORS AND COILS. JDC 2. PIPING SLEEVED AND SEALED THROUGH ROOF OR WALL. r_v BHC, CUH HEATING COIL THREE WAY MOTORIZED VALVE 3. ALL VALVES OF REFRIGERANT TYPE. CHECKED BY 4. ISOLATING VALVES AT ACCU ARE NOT SHOWN. NOTE: SUPPORT @ 48" Rick Silenzi 3 COIL PIPING DIAGRAM 6 REFRIGERANT PIPING DIAGRAM 9 ROOF MOUNTED REFRIGERANT PIPE JOB NO. 2020-0465 NO SCALE NO SCALE NO SCALE DATE 01/11/2021 SHEET NUMBER BID SET M8. 1 FILE: M81 DURHAM.DWG - MBA EDIT: 12/16/2020 10:31 AM BY JONATHANC I PLOT: 1/11/2021 3:05 PM BY JONATHAN COPE INTERFACE E N G I N E E R I N G �- 100 SW Main Street _ Suite 1600 Portland, OR 97204 503.382.2266 t.-.. ` www.interfaceengineehng.com 9 Eog 51�� f SSi _ 99_ 1 ED PROF �aGINffA o OREGON �ZOR°rae.� � , \ z r- ALV W.FPG EXPIRES. 1231:2 i - r F - .� �a CONDENSING UNIT ACU-1 TO BE REPLACED. PROVIDE NEW CROSS CONDENSING UNITS ACU-2 AND ACU-3 TO BE REPLACED. PROVIDE ACU-5 TO BE REPLACED. PROVIDE GALVANIZED STEEL SUPPORT MEMBER SUPPORT ON CURB TO ACCOMMODATE NEW UNIT. GALVANIZED STEEL SUPPORT CROSS MEMBERS FOR SUPPORT AND CROSS MEMBERS FOR SUPPORT AND ANCHOR TO EXISTING ROOF ANCHOR TO EXISTING ROOF CURB AS REQUIRED. CURB AS REQUIRED. V 1 PHOTO DETAIL 2 PHOTO DETAIL 3 PHOTO DETAIL J NO SCALE NO SCALE NO SCALE O 00 J = O W _ >= U) Q r Z ZLLJ C� Q NOW In W J N J ' N n - W V 2z � ao : W LU n ^n � o { Uj CD ` • , 0 ti SHEET TITLE PHOTO DETAILS - MECHANICAL REVISIONS CU-6 TO BE REPLACED. PROVIDE GALVANIZED STEEL SUPPORT CU-7 UNIT TO BE REPLACED. ANCHOR TO EXISTING ROOF CURB ACU-8 TO BE REPLACED. PROVIDE GALVANIZED STEEL SUPPORT CROSS MEMBERS FOR SUPPORT AND ANCHOR TO EXISTING ROOF AS REQUIRED. CROSS MEMBERS FOR SUPPORT AND ANCHOR TO EXISTING ROOF CURB AS REQUIRED. CURB AS REQUIRED. 4 PHOTO DETAIL 5 PHOTO DETAIL 6 PHOTO DETAIL DRAWN BY NO SCALE NO SCALE NO SCALE JDC CHECKED BY Rick Silenzi JOB NO. 2020-0465 DATE 01/11/2021 SHEET NUMBER BID SET M8.2 FILE: M82 DURHAM.DWG — M8.2 EDIT: 1/11/2021 10:29 AM BY JONATHANC I PLOT: 1/11/2021 11:04 AM BY JONATHAN COPE ELECTRICAL SYMBOL LIST NOTE: This is a standard symbol list and not all items listed may be used. I N T E R F A C E E N G I N E E R I N G Abbreviations IN INCH, INCHES TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR Raceways KV KILOVOLT TYP TYPICAL (E) EXISTING CONDUIT CONCEALED IN WALL OR CEILING SPACE (N) NEW KVA KILOVOLT AMPERES UL UNDERWRITERS LABORATORIES 100 SW Main Street KW KILOWATT UON UNLESS OTHERWISE NOTED —— — — ——— CONDUIT ROUTED BELOW FLOOR/GRADE Suite 1600 (R) RELOCATE Portland, OR 97204 503.382.2266 (X) DEMOLISH LED LIGHT EMITTING DIODE V VOLTS, VOLTAGE ✓w....v.,. FLEXIBLE CONDUITwww.intertaceen ineerin 9 9.com LFMC LIQUIDTIGHT FLEXIBLE METAL CONDUIT W/ WITH A AMPERES,AMBER — _ _ EXISTING CONDUIT CONCEALED IN WALL OR CEILING SPACE LV LOW VOLTAGE W/O WITHOUT AFC ABOVE FINISHED CEILING ,BRED PROFffS MCA MINIMUM CIRCUIT AMPS WP WEATHERPROOF I FF goy AFF ABOVE FINISHED FLOOR yr MCC MOTOR CONTROL CENTER XFMR TRANSFORMER AHJ AUTHORITY HAVING JURISDICTION MIN MINIMUM y REGON b AIC AVAILABLE INTERRUPTING CAPACITY Connections / Equipment Zw.4"SH11,2���f MISC MISCELLANEOUS % R. SA ` ANSI AMERICAN NATIONAL STANDARDS INSTITUTE MOCP MAXIMUM OVERCURRENT PROTECTION HEAVY DUTY FUSED DISCONNECT SWITCH hPLY,-S ;o;:'.G i2 AWG AMERICAN WIRE GAUGE BAS BUILDING AUTOMATION SYSTEM MT, MTD MOUNT, MOUNTED WALL-MOUNTED JUNCTION BOX C CONDUIT, CLOSE, CONTROL N.I.C. NOT IN CONTRACT J JUNCTION BOX WITH FLEX CONNECTION TO EQUIPMENT CA CABLE N/A NOT APPLICABLE N NEUTRAL MOTOR CONNECTION COORD COORDINATE CU COPPER NEC NATIONAL ELECTRIC CODE NON-FUSED DISCONNECT SWITCH NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION DIM DIMENSION DIV DIVISION NESC NATIONAL ELECTRIC SAFETY CODE General NTS NOT TO SCALE DN DOWN _X_X_ DEMOLISH DTL DETAIL OC ON CENTER r 1 PH PHASE EXISTING WORK DWG DRAWING E EMERGENCY PNL PANEL NEW WORK PVC POLY-VINYL-CHLORIDE V♦ 0 O EA EACH _X EQUIPMENT IDENTIFICATION EF EXHAUST FAN PWR POWER LOCATION O EMT ELECTRICAL METALLIC TUBING QTY QUANTITY O KEYED NOTE J FA FIRE ALARM REQD REQUIRED O FMC FLEXIBLE METAL CONDUIT RFI REQUEST FOR INFORMATION Miscellaneous OUj FT FOOT, FEET RM ROOM BRANCH PANEL G RMC RIGID METAL CONDUIT G, GND GROUND �r FLUSH WALL MOUNTED BRANCH PANEL V, GFCI GROUND FAULT CIRCUIT INTERRUPTER SHT SHEET STD STANDARD MAIN DISTRIBUTION PANEL/SUB DISTRIBUTION PANEL Z A GFI GROUND FAULT INTERRUPTER W li SWBD SWITCHBOARD GFP GROUND FAULT PROTECTION TBD TO BE DETERMINED J cm W D N HT HEIGHT � LVQ 2z I— V = 0 � QQ � M Q = = 00 Uj 30 Go SHEET TITLE COVER SHEET - ELECTRICAL REVISIONS DRAWN BY IEI CHECKED BY Jeff Glanville SHEET INDEX JOB NO. 2020-0465 E1.0 COVERSHEET-ELECTRICAL Reference on ly DATE E1.1 SCHEDULES-ELECTRICAL Not01/11/2021 part of this permit ED2.1 ROOF PLAN-DEMOLITION - ELECTRICAL SHEET NUMBER E2.1 ROOF PLAN-ELECTRICAL BID SET E1 .0 FILE: E10 DURHAM.DWG - E10 ( EDIT: 1/11/2021 5:08 PM BY JEFFREYG PLOT: 1/11/2021 5:08 PM BY JEFFREY GLANVILLE MECHANICAL EQUIPMENT CONNECTION SCHEDULE VOLTS/ WIRE / INTERFACE ITEM DESCRIPTION LOCATION PHASE LOAD MCA MOCP CONDUIT CIRCUIT NOTES ACU-1 CONDENSING UNIT ROOFTOP 208/3 121 150 1253 E N G I N E E R I N G 1 ACU-2 CONDENSING UNIT ROOFTOP 208/3 60 80 603 1 ACU-3 CONDENSING UNIT ROOFTOP 208/3 60 80 603 1 ACU-5 CONDENSING UNIT ROOFTOP 208/3 121 150 1253 1 ACU-6 CONDENSING UNIT ROOFTOP 208/3 1 100 SW Main Street ACU-7 CONDENSING UNIT ROOFTOP 208/3 17 1 25 1 203 1 Suite 1600 7204 ACU-8 CONDENSING UNIT ROOFTOP 208/3 1 1 Portland, OR 503.382.2262.226 6 www.interfaceengineering.com GENERAL MECHANICAL EQUIPMENT CONNECTION SCHEDULE NOTES A. THE ABOVE INFORMATION IS FOR A SPECIFIC MANUFACTURER. ACTUAL MANUFACTURER FOR EQUIPMENT MAY BE DIFFERENT. COORDINATE WITH MECHANICAL EQUIPMENT SUBMITTALS FOR LOADS AND OVER CURRENT PROTECTION ED PROS REQUIREMENTS PRIOR TO INSTALLATION OF WIRING. 5"<� G 1 N fss� 0 B. MOCP = MAXIMUM OVER CURRENT PROTECTION Q MCA = MINIMUM CIRCUIT AMPACITY C. PROVIDE DISCONNECTING MEANS FOR EACH ITEM OF EQUIPMENT LISTED IN THE SCHEDULE ABOVE, EXCEPT AS RE N SPECIFICALLY NOTED OTHERWISE IN SCHEDULE NOTES, BELOW. i9�QecHii,l41°�. Mfs R. SA�� MECHANICAL EQUIPMENT CONNECTION SCHEDULE NOTES EXPIRES. 06/30122 1 RECONNECT TO EXISTING FEEDER. CONTRACTOR TO FIELD VERIFY THAT EXISTING FEEDER MEETS OR EXCEEDS SIZE SHOWN IN WIRE/CONDUIT SCHEDULE. IF EXISTING FEEDER DOES NOT MEET OR EXCEED SIZE SHOWN, REPLACE EXISTING FEEDER WITH NEW PER SCHEDULE. WIRE/CONDUIT SCHEDULE 203 3 #12 CU, 1 #12 CU GND., IN 3/4" C. 603 3 #4 CU, 1 #10 CU GND., IN 1" C. 1253 3 #1 CU, 1 #6 CU GND., IN 1-1/4" C. 2003 3 #3/0 CU, 1 #6 CU GND., IN 2" C. V � J O 00 J = 0 (m) U) W U) Q Z IMM C� Q W = C4 JWJo � Dwa Mz H V =0 � aQ WIWI co � W0 inw W 00 (D H0 � ti � SHEET TITLE SCHEDULES - ELECTRICAL REVISIONS 1 ADDENDUM 1 2/2/2021 DRAWN BY IEI CHECKED BY Jeff Glanville Reference JOB NO.eference only 2020-0465 Not part of this permit DATE 01/11/2021 SHEET NUMBER BID SET E1 . 1 FILE: Ell DURHAM.DWG — Ell EDIT: 2/1/2021 11:57 PM BY JEFFREYG PLOT: 2/1/2021 11:58 PM BY JEFFREY GLANVILLE O SHEET KEYNOTES 1 PROVIDE CONNECTION TO NEW HVAC UNIT VIA NEW WEATHERPROOF FUSED DISCONNECT AS SHOWN. SEE ELECTRICAL FOR ADDITIONAL EQUIPMENT CONNECTION SCHEDULE ON E1.1 INFORMATION. INTERFACE FOVIDE NEW ROOFTOP MAINTENANCE RECEPTACLE WITH E N G I N E E R I N G -CAST WHILE-IN-USE COVER TO REPLACE REMOVED ICE. RECONNECT TO EXISTING CIRCUIT. VIDE CONNECTION TO NEW HVAC UNIT VIA NEW ATHERPROOF FUSED DISCONNECT AS SHOWN. SEE CTRICAL EQUIPMENT CONNECTION SCHEDULE ON E1.1 100 SW Main Street FOR ADDITIONAL INFORMATION. PROVIDE NEW NEMA 3R Suite 1600 BUSSED GUTTER TO REPLACE REMOVED GUTTER AND Portland, OR 97204 RECONNECT EXISTING FEEDER. FEED NEW UNITS FROM 503.382.2266 NEW BUSSED GUTTER. www.interfaceengineering.com 4 REPLACE EXISTING 125A/3P BREAKER IN PANEL'B' FEEDING ACU-1 WITH NEW 150A/3P BREAKER, BREAKER TO MATCH EXISTING MANUFACTURER AND AIC RATING. f D PROF D-K D-J CD-H D-Ci D-F D-E �-D) �,B A.1 1 ���N�I N F fSJ/0 r x Q EGO I R5 �1 EXPIRES:06/30/22 - I------ ------ i AREA 1 MECHANICAL I ( Y ROOM 1 t OD-2 D•2 I 1 ACU-1 1 4 (E) PANEL'B' MECHANICAL ROOM Ej ) PANEL (ON GROUND LEVEL) I '2MA95' F AR 12 1 2 I wP AREA 13 II DC D-03 2 Tb SEC D-3 — w wnl 1 1 r � I AR _- ° O I 1 ACU-5 I AREA 8 l I BSC REA 6 --!--- --- J , 1 I O V U) o-s - -- - r--- - -I - - - - - +— -----` - - - - i _ - - - - - - - --- D-5LU 1 I - (E)SKYLIGHT I ' I ' D� - - - - - - - - -- - - '- -- - - — - - - - - -- - - - - D-B I I ----- ------..---------------- ♦^ ?-A Z V AREA 9 1 Uj - - _____. _- _.__ __. ___ ____._ _- - __ ._ ___ _____. ._ ._ to � I I _- _ - _-- - --< - - - -_ _ -- - - -- - -- - -- - ---- - --- - -- - Q 2 D D-7 D-8 AREA 4I E( )PANES I .� W ,� N '2M895' > � - - -- - 1 F wa ACU-6 1 3 ACU-2 XAA Att# T- AREA 16AREA 21 W 2 Z -8. -- t � � -ARE z - - - - - - - - --- - --- -8. - - - —__ _ _-- _ - - - - - -- - - --- _ -_ - - -- - - --- - --- -- - I� W AR! w — _ - - D� wa F 2 (E) PANEL'F' _. - - -- - - - -- G O ;T -- - - - - - -- - - - ♦�1 LXL 3 ACU-3 Nm F �..... ----------- --------- E PANEL AR 22 V w 2MC95' -1 MECHANICAL ROOM - I SHEET TITLE I 1 AREA 11 I I i I AREA 17 AREA i6b AREA 24 I ROOF PLAN - IELECTRICAL _ - --------- --- ---- -- -- - - - r I I I 1 I i I i i AREA,23 2 FF REVISIONS -------_ �_.. I — I— — --- — — --- 1 ADDENDUM 1 2/2!2021 AREA 18a I wP ROOM MECHANICAL 1 ACU-8ROOM""".."""""I—MECHANICAL - - - - - -- - - - — -- - - --- - — -- I- - -- -- _ AREA 191 - - ACU-7 - - -- - - - -- - - - -- - - _ -- - - - ---------- - I I I I I I I I I DRAWN BY I CHECKED BY ! Jeff Glanville D$ 41.1 D-A -A.1 A.1 JOB NO. 2020-0465 DATE " 1 ROOF PLAN - ELECTRICALp pY� C� 01/11/2021 T 0 8' 16' 32' Aefeil�em�a ulily SHEET NUMBER " Not part of this permit SCALE: 1/16"=1'-0" BID SET ' FILE: E21 DURHAM.DWG — E21 EDIT: 2/1/2021 11:52 PM BY JEFFREYG I PLOT: 2/1/2021 11:52 PM BY JEFFREY GLANVILLE O SHEET KEYNOTES 1 EXISTING ROOFTOP MECHANICAL UNIT AND ASSOCIATED DISCONNECT TO BE REMOVED AND REPLACED. MAINTAIN ep CONTINUITY OF EXISTING FEEDER TO DISCONNECT LOCATION FOR RECONNECTION TO REPLACEMENT UNIT. INTERFACE 2 EXISTING WEATHERPROOF RECEPTACLE TO BE REPLACED, E N G I N E E R I N G MAINTAIN CONTINUITY OF EXISTING CIRCUIT FOR RECONNECTION TO REPLACEMENT DEVICE. 3 EXISTING ROOFTOP MECHANICAL UNIT AND ASSOCIATED DISCONNECT TO BE REMOVED AND REPLACED. EXISTING BUSSED GUTTER FEEDING ACU-2 AND ACU-3 TO ALSO BE 100 SW Main Street REPLACED. MAINTAIN CONTINUITY OF FEEDER TO BUSSED Suite 1600 GUTTER FOR RECONNECTION TO REPLACEMENT. Portland, OR 97204 503.382.2266 4 EXISTING ROOFTOP MECHANICAL UNIT,ASSOCIATED www.interfaceengineering.com DISCONNECT,AND FEEDER TO BE REMOVED AND REPLACED. FEEDING BREAKER IN PANEL'B'TO BE REPLACED. SEE SHEET E2.1 FOR ADDITIONAL INFORMATION. Q-L.� D-F D-E D-D D-C D-B A.1 1 ��\�tit�vG I PRO, S/ ERCH I J�MFS R. SA�� I D-1 ----- -- �- - ----- - -- --I - - - --- � � - - I �� -- - - D-1 EXPIRES:06130/22 i ----------- - AREA 1 MECHANICAL I ---------- I ROOM D-2I 40 (x)ACU-1:: r 1 MCA: 109A MECHANICAL ROOM FED FROM BREAKEI R IN X (E)PANEL 'B' � (E) PANEL PANEL'B' x (ON GROUND '2MA95' 1 LX � AR 12 LEVEL ! AREA 13 Tb { 1 2 I SEL 0 AREA 1 (X)ACU-5: 1 O MCA: 129A I AREA 8 1 BEL I FED FROM 175A/3P BREAKER IN PANEL'2MA95' J AREA 6 ; � I i ♦♦^^ LUO Cn v♦ (E)51(Y'LIOHT O ♦^ I v♦ Q i I Pte/ I D-A -A.1 -A.1 -A.1 -A.1 A.1 -A.1 -A.2 z a. Z D-' I s + AREA 91 4U - - - - - -- - -- - --- .d - - -- - --�- - -- Q D-8 AREA 4 E PANEL I J W J o N '2MB95' - - - -- �I I I 1 1 (X)ACU 6: 1 AREA 16 A A 0 AREA 21 E PANEL W V Q O 7 IMCA: 129A I I I Iz I _ -8. I 2 FED FROM 175A/3P - __` BREAKER IN PANEL'2MB95' D-8 �- � � AR xLX x 2 (E)PANEL'F' (X)ACU-2: -MCA: 62.7A -9, ( W 3 FED FROM BREAKER IN XrX f I - ----- -------- ------- ------ -----, E PANEL I I AREA 22 - Q LL V W 2MC95' PANEL'F I O Q (X)ACU 3: - t— - - -- - - -- - - - - - - - - - -- — - - - - - — - -- - _ - - f � LU � c� MCA. ' FED FROM BREAKER IN - MECHANICAL ROOM �— PANEL'F' SHEET TITLE 11 I AREA 11 ! � I AREA 17 I I AREA 18b AREA 24 ROOF PLAN - __� I DEMOLITION - 4- - - - - �- — - - - . - - - -- - - - ---- - - - -f --- - - - - - - __- - -- - - - ELECTRICAL ! I I _ ____ ___ ____ _ C I I ( I I ARES 23 �X t /�� X REVISIONS ..---__+- - __. _______ - i .,�,�„x;�::�,,::,,,�,. _ , �,,.. .�---- i - I I _. ------ - _ f 1 MCA: _..... W - - --�- -- ----- - ---- - - - -- 1 ADDENDUM 1 21212021 \\\ /✓// I CU-8: AREA 18a :FROM MECHANICAL MECHANICAL FED FROM 225A/3P MECHANICAL BREAKER IN PANEL'2MD95 ROOM I _- -ROOM - -- ROOM _ - - - __. - -- AREA 19, MCA: 17A _ --- - — - -- 1 (x>ACU-7:44. �� FED FROM 25A/3P BREAKER -- '--- -- - -14. - - - . -- �� �— - - - _ ? INPANEL'2MC95' -- - - -- I- - -- - - - -- - - - -- - -- - - - I I I I I ( ! --- -- ---- DRAWN BY _ � - - — IEI CHECKED BY Jeff Glanville JOB NO. -L. 4. -L. -L. D-L D-K D-J C-)H -G D-F ID-E D-D D-C D-B -A.1 D-A C-A.1 A.1 C C C-A.1 �A ?� 2020-0465 DATE 1 ROOF PLAN - DEMOLITION - ELECTRICAL 01/11/2021 H 0 8' 16' 32' Deference Onix SHEET NUMBER SCALE: 1/16"=V-0" �Ot part Of this permit BID SET EWA FILE: ED21 DURHAM.DWG - ED21 EDIT: 2/1/2021 11:50 PM BY JEFFREYG PLOT: 2/1/2021 11:52 PM BY JEFFREY GLANVILLE