Loading...
Plans (18) M EC2020-00046 ( 2/2 ) OFFICE COPY GENERAL NOTES ABBREVIATIONS 1. MECHANICAL WORK COMPLIES WITH THE 2019 OREGON ZERO ENERGY READY COMMERCIAL CODE,ASHRAE 90.1 2016,2019 OREGON Arc AIR CONDITION(ED) CD CONDENSATE DRAIN EQUIP EQUIPMENT IN INCHES OSA OUTSIDE AIR TYP TYPICAL STRUCTURAL SPECIALTY CODE AND THE 2019 OREGON MECHANICAL SPECIALTY CODE INCLUDING APPENDIX C-FUEL GAS. AD ACCESS DOOR CFM CUBIC FEET PER MINUTE ERV ENERGY RECOVERY VENTILATOR LAT LEAVING AIR TEMPERATURE PSI FOUNDS PER SQUARE INCH V VOLT AFF ABOVE FINISHED FLOOR CLG CEILING ESP EXTERNAL STATIC PRESSURE LF LINEAR FEET QTY QUANTITY VD VOLUME DAMPER(HAND OPERATOR) 2. WORK INCLUDES AN ALTERATION OF AN EXISTING BUILDING. ALT ALTERNATIVE CND CONDENSATE DRAIN EXH EXHAUST MA MIXEDAIR RA RETURN AIR VFD VARIABLE FREQUENCY DRIVE AL ALUMINUM CONIC CONCRETE EXIST EXISTING MAX MAXIMUM RET RETURN VRV VARIABLE REFRIGERANT VOLUME APD AIR PRESSURE DROP CONT CONTINUE(D)(ATION) EXP EXPANSION MBH THOUSAND BTU PER HOUR REV REVISION W/ WITH 3. MECHANICAL EQUIPMENT REPLACING EXISTING EQUIPMENT COMPLIES WITH APPLICABLE REQUIREMENTS OF THE NEW CODE.ASHRAE APPROX APPROXIMATELY CL CENTERLINE F DEGREES FAHRENHEIT MD MOTORIZED DAMPER RH RELATIVE HUMIDITY WB WET BULB 90.1-6.1.1.3.1 ARCH ARCHITECT(URAL) DDC DIRECT DIGITAL CONTROL FC FLEXIBLE CONNECTOR MECH MECHANICAL RPM REVOLUTIONS PER MINUTE WC WATER COLUMN AUTO AUTOMATIC DEFL DEFLECTION FD FIRE DAMPER MFG MANUFACTURER SA SUPPLY AIR W/O WITHOUT � 4. THE SIMPLIFIED APPROACH TO COMPLIANCE WITH ASHRAE 90.1 IS USED. THE BUILDING IS TWO STORIES TALL OR LESS AND HAS A GROSS BDD BACKDRAFT DAMPER DN DOWN FPM FEET PER MINUTE MH MOUNTING HEIGHT SF SQUARE FEET WPD WATER PRESSURE DROP AREA LESS THAN 25,000 SQUARE FEET. HVAC SYSTEMS ARE SINGLE ZONE SYSTEMS. BHP BRAKE HORSE POWER DWG DRAWING FSD FIRE SMOKE DAMPER MIN MINIMUM SH SENSIBLE HEAT W WATT BLDG BUILDING EAT ENTERING AIR TEMPERATURE FT FEET N/A NOT APPLICABLE SP STATIC PRESSURE KW KILOWATT HVAC/R • CONTROLS BOD BOTTOM OF DUCT EF EXHAUST FAN FV FACE VELOCITY NC NOISE CRITERIA SPEC SPECIFICATION 5. COOLING EFFICIENCY OF UNITS COMPLIES WITH TABLES 6.8.1-1,6.8.1-2 OR 6.8.1-4. BOP BOTTOM OF PIPE EFF EFFICIENCY GA GAGE/GAUGE NC NORMALLY CLOSED SS STAINLESS STEEL BSMT BASEMENT ELEC ELECTRIC(AL) GALV GALVANIZED NC NORMALLY OPEN TD TEMPERATURE DIFFERENCE CONTRACTORS • ENGINEERS 6. INSTALL HEATING EQUIPMENT THAT MEET THE MINIMUM EFFICIENCIES REQUIREMENTS OF ASHRAE 90.1 TABLES 6.8.1-2,6.8.1-4,6.8.1-5 AND BTUH BRITISH THERMAL UNIT PER HOUR ELEV ELEVATION HP HORSE POWER NTS NOT TO SCALE TEMP TEMPERATURE 6.8.1-6. CD CEILING DIFFUSER EQ EQUAL ID INTERNAL DIAMETER OD OUTSIDE DIAMETER TO TOTAL PRESSURE SERVICE • MAINTENANCE 7. EXHAUST SYSTEMS ARE EXPECTED TO OPERATE LESS THAN 8000 HOURS PER YEAR;THEREFORE NO EXHAUST ENERGY RECOVERY SYSTEM IS HVAC DUCT SYMBOLS INCLUDED IN THE DESIGN.(ASHRAE 90.1-TABLE 6.5.6.1-1) FITTING SINGLE LINE DOUBLE LINE FITTING SINGLE LINE DOUBLE LINE FITTING SINGLE LINE DOUBLE LINE SINGLE LINE ITEM TAG (503) 234-0477 • hunterdavisson.com 30°TRANSITIO Fc - 8. INSTALL MANUAL CHANGEOVER OR DUAL SET-POINT THERMOSTATS. VOLUME DAMPER �Tj CONCENTRIC 2---D-� NON-SYMMETRICAL SUPPLY AIR ® ® FAN COIL UNIT COIL TYPE SQUARETO15°MAX �ROUND WYE ' UTSIDEAIR FLOOR-1-,­fMCOIL NUMBED SON FLOOR) FD CONCENTRIC //----rr��----�� RETURN AIR 9. INCLUDE INTERNAL SUPPLEMENTAL ELECTRIC RESISTANCE HEATERS IN HEAT PUMPS. LIMIT SUPPLEMENTAL HEATER OPERATION TO COMPLY FIRE DAMPER �Tj ��� � DOUBLE FORMED VRV SYSTEM vRv-, wvNUMBER Isrs.eul . ROUND TRANSITION 15°MAX TURNING VANES EFERs To vRv SYSTEM WITH ASHRAE 90.1-6.3.2(h). EXHAUST AIR ,y 90'RECTANGULAR RECTANGULAR �--j ® FAN COIL UNIT Fc,-, µcaieuwBER ��� PR ELBOW WITHECCENTRIC -1 Y TURNING VANES �'� (RECTANGULAR �� MAX DUCT RISER ROOM THERMOSTAT ETERS TO VRV SYSTEM y�� I N '. AC-I-UNIT CONTROLLED BRANCH 10. INSTALL A SEVEN DAY TIME CLOCK FOR EACH SYSTEM HAVING COOLING OR HEATING CAPACITY GREATER THAN 15,000 BTU/H AND A FAN OR ROUND) ROUND �� ® as.,-, RANCR SELECTOR NNMBER !F, rP R_W DUCT RISER SELECTOR -',�''. -j POWER GREATER THAN 7.5 HP. PROVIDE CONTROLS THAT CAN BE PROGRAMMED TO START AND STOP THE SYSTEM UNDER DIFFERENT EXTRACTOR oNNEcnoNsvEPE Z SCHEDULES FOR SEVEN DIFFERENT DAY TYPES PER WEEK,THAT WILL RETAIN PROGRAMMING FOR 10 HOURS DURING A LOSS OF POWER,AND RADIUS ELBOW EX RECTANGULAR �---� DIFFUSER, -TYRE W D W EX DUCT DROP `, THAT HAVE A TWO HOUR MANUAL OVERRIDE.CONFIGURE SETBACK HEATING SET-POINT TO 55 F AND SETUP COOLING SET-POINT TO 90 F ROUN REGISTER n.Pz-TYRicu d' , I l�. r &GRILLE oucT ROUND �'-�� ® CONNECTION 'I ti2EGON M DURING UNOCCUPIED HOURS. RECTANGULAR DUCT DROP sieE OT NUMBER a SLOT saE MAIN WITH j1F ROUND MAIN LINEAR SLOT a' -r ., -TYRE RECTANGULAR / L DUCT WITH BRANCH CAL ROUND RECTANGULAR DIFFUSER TYPz-TFcicu �.ys `' 1 3 .ZO�[� 11. INSULATE HVAC PIPING TO MEET THE REQUIREMENTS OF TABLES 6.8.3-1,AND 6.8.3-2. PROTECT OUTDOOR PIPING INSULATION FROM BRANCH 4555°"=" fi" ROUND BRANCH TEE BRANCH OFFSET>15° FM ~t' DAMAGE. C � EXPIRES: 06/30/2020 12. INSULATE DUCTWORK TO MEET THE REQUIREMENTS OF TABLE 6.8.2.CONSTRUCT DUCTWORK AND PLENUMS TO SEAL CLASS A. SEAL ALL CONNECTIONS(EXCEPT SPIRAL DUCT CONNECTIONS). DESIGN CONDITIONS - PORTLAND, OREGON SHEET INDEX 13. AIR-BALANCE DUCTED SYSTEMS IN ACCORDANCE WITH INDUSTRY STANDARDS. SPACE WINTER SUMMER SHEET SHEET REV REV TEMPERATURE HUMIDITY TEMPERATURE HUMIDITY # NAME # DATE 14. DESIGN MINIMUM OUTDOOR AIR CFM DOES NOT EXCEED 135%OF THE MINIMUM OUTSIDE AIR REQUIRED BY THE GMSC. INDOOR 70°F t 2°F DB NOT CONTROLLED 75°F t 2°F DB NOT CONTROLLED M000 MECHANICAL COVER PAGE 15. PREVENT SIMULTANEOUS HEATING AND COOLING WITH ZONE CONTROLS. OUTDOOR 25.2°F DB N/A 91.4°F DB/67.3°F MCWB 28.1% RH MOO( MECHANICAL SCHEDULES NOTES: MD101 DEMO PLANS 16. UNLESS OTHERWISE INDICATED, DOORS TO OUTSIDE ARE PROVIDED WITH AUTOMATIC DOOR CLOSERS OR ARE LOCATED IN SPACES WITHOUT 1. OUTDOOR CONDITIONS BASED ON ASHRAE FUNDAMENTALS 2013, 99.6% &0.4% DATA M101 LEVEL ONE FLOOR PLAN THERMOSTATS. DOOR SWITCHES FOR HVAC CONTROL ARE NOT REQUIRED. M102 LEVEL TWO FLOOR PLAN M103 ROOF PLAN MINIMUM INSULATION R-VALUE FOR HVAC DUCT SYSTEMS (OREGON) DUCT LOCATION DUCT TYPE OUTSIDE RETURN COOLING HEATING AIR AIR SUPPLY SUPPLY Lu EXTERIOR OF BUILDING (1) 8.0 8.0 6.0 SCOPE OF WORK: 2 UNCONDITIONED SPACES(2) 8.0 6.0 6.0 1. DEMO AND RECYCLE EXISTING ROOFTOP AIR CONDITIONERS AND CONDENSING INDIRECTLY CONDITIONED SPACES (RETURN AIR PLENUMS) - - 1.9 1.9 UNITS. Lu uj FULLY CONDITIONED SPACES 2. DEMO AND Nc-CYCLE EXISTING CEILING MOUNTED FAN COIL UNITS ON FIRST FLOOR. Q NOTES: C3. FURNISH AIdD INSTALL (X8) NEW FAN COIL UNITS ON FIRST FLOOR ANn(X4) NEW THIS TABLE IS IN ACCORDANCE WITH ASHRAE 90.1 2016 TABLE 6.8.2. SPLIT-SYSTEM HEAT PUMPS ON ROOF. a 1. INCLUDES ATTICS ABOVE INSULATED CEILINGS, PARKING GARAGES AND CRAWL SPACES 2. INCLUDES UNCONDITIONED, UNVENTED SPACES SUCH AS UNVENTED MECH. ROOMS, SHAFTS, OR PLENUMS IN THE BUILDING 4. CLEAN, PURGE AND REUSE REFRIGERANT PIPING FROM NEW FAN COILS TO ENVELOPE CONNECT TO NEW SPLIT-SYSTEM HEAT PUMPS. REPAIR INSULATION AS REQUIRED. 3. RUNOUTS TO TERMINALS OR OUTLETS DO NOT REQUIRE MORE THAN R-3.5 INSULATION. 5. FURNISH AND INSTALL SUPPLY AND RETURN DUCT WORK TRANSITIONS FROM NEW OR PLENUM DOES NOT EXCEED 15°F UNITS TO EXISTING DUCTWORK. 0 UJ OWENS CORNING SOFT-R DUCTWRAP FRK WITH A THICKNESS OF 2.2" HAS AN INSTALLED RATING OF R-6.0 OWENS CORNING SOFT-R DUCTWRAP FRK WITH A THICKNESS OF 3" HAS AN INSTALLED RATING OF R-8.3 6. FURNISH AND INSTALL NEW CONDENSATE DRAINS FROM ROOFTOP UNITS TO ROOF. Imm u 7. CONNECT NEW FAN COILS TO EXISTING CONDENSATE DRAINAGE. 8. FURNISH AND INSTALL(X8) NEW 7-DAY PROGRAMMABLE THERMOSTATS FOR 7080 SW FIR LOOP SPLIT-SYSTEMS AND ROOFTOP HEAT PUMPS. TIGARD, OR 9. START, CHECK AND ADJUST SYSTEMS C'TTV nr. r. NPD REA'tl tI I :_. i,u:1'.PMANCE REVISIONS Approl'cd: OTC:: I ] 1 ADJUST SCOPE 2/17/2020 o Permit D,02p aw Address: AREA OF WORK: 7 c� RcZ_ i Scute#: a`t $fir, Date: CL w 0 0 .L .3 c U Co SW Varns St SW Varns St SW Varus SI U 7 DATE 12/18/2019 o v VALIDITY OF PERMIT EISSUANCE OF A F f ERMIT BASED ON CONSTRUCTION DRAWN BY STC o DOCUMENTS AND HER DATA SHALL NOT PRET ENT CHECKED BY TW cn Ir THE CODE OFFICIAL FROM L REQUIRING THE CORRECTION OF ERRORS.OSSC 105.4 MECHANICAL r. 17CSO owl, TIT Loop COVER PAGE C W r O N y U C ,q O m000 Cu PERMIT = DRAWING 0 MECHANICAL OSA CALCULATIONS FLOOR OUTDOOR AIR OCCUPANT NUMBER OF OUTDOOR AIR PER BREATHING EFFECTIVENESS, ZONE OSA, ZONE AIRFLOW, ZONE OSA SYSTEM VENT. SYSTEM OCCUPANT UNCORRECTED MINIMUM OUTSIDE EXHAUST SYSTEM ROOM NAME ZONE SPACE TYPE AREA, Az PER AREA, Ra DENSITY OCCUPANTS, PERSON, Rp ZONE, V6z Ez Voz VPz FRACTION, Zp EFFICIENCY, Ev POPULATION, Ps DIVERISTY, D OUTSIDE AIR, Vou AIR, VoT FRESH AIR NOTES Pz REQUIRED DESIGNED SOURCE (SF] [CFM/SF] [#/1000 SF] [CFM/PERSON] [CFM] (_) [CFM] [CFM] (_) (CFM] (_) (_) (CFM] (CFM] (CFM] (CFM] ADJACENT OFFICE 1 NW OFFICE 1,034 0.06 5 5.2 5 88 0.8 110 1,523 0.07 88 FC-1 RESTROOM 1 NW TOILET ROOM 52 0 0 0 5 0 0.8 0 77 0.00 1.0 6.0 1.0 0 88 80 80 FC-1 - TOTALS: 1,086 6 88 110 1,600 88 FC-2 ADJACENT OFFICE 1 NE OFFICE 1,222 0.06 5 6.1 5 104 0.8 130 1,600 0.08 1.0 7.0 1.0 104 104 F FC-2 TOTALS: 1,222 7 104 130 1,600 104 OFFICE 1 1 SW OFFICE 274 0.06 5 1.4 5 23 0.8 29 283 0.10 22 - OFFICE 1 SW OFFICE 188 0.06 5 0.9 5 16 0.8 20 194 0.10 15 HVAC/R • CONTROLS OFFICE 3 1 SW OFFICE 115 0.06 5 0.6 5 10 0.8 12 119 0.10 9 FC-3 OFFICE 1 SW OFFICE 148 0.06 5 0.7 5 13 0.8 16 153 0.10 0.9 17.0 0.8 12 182 FC-3 CONTRACTORS ENGINEERS CONFERENCE RM 1 SW CONFERENCE 343 0.06 50 17.2 5 106 0.8 133 540 0.25 87 BAR 1 SW OFFICE 57 0.06 5 0.3 5 5 0.8 6 59 0.10 5 SERVICE • MAINTENANCE CORRIDOR 1 SW CORRIDOR 243 0.06 0 0.0 0 15 0.8 18 251 0.07 15 TOTALS: 1,368 22 187 234 1,600 163 OFFICE 4 1 SE OFFICE 150 0.06 5 0.8 5 13 0.8 16 156 0.10 11 WORKROOM 1 SE WORKROOM 305 0.06 4 1.2 5 24 0.8 31 317 0.10 24 (503) 234-0477 • hunterdavisson.com CIRC 1 SE CORRIDOR 317 0.06 0 0.0 0 19 0.8 24 329 0.07 19 FC-4 FRONT OFFICE 1 SE OFFICE 137 0.06 5 0.7 5 12 0.8 15 142 0.10 1.0 5.0 0.6 10 112 FC-4 BUILDING ENTRY 1 SE ENTRY LOBBY 290 0.06 10 2.9 5 32 0.8 40 301 0.13 26 TOILET ROOM 1 SE TOILET ROOM 36 0 0 0.0 0 0 0.8 0 0 0.00 80 80 PR OFFICE 5 1 SE OFFICE 305 0.06 5 1.5 5 26 0.8 32 317 0.10 23 TOTALS: 1,540 8 126 157 1,663 112 OFFICE 12 2 NW OFFICE 103 0.06 5 0.5 5 9 0.8 11 132 0.08 9 W r OFFICE 13 2 NW OFFICE 151 0.06 5 0.8 5 13 0.8 16 193 0.08 13 a i�1f7REGONq r OFFICE 14 2 NW OFFICE 119 0.06 5 0.6 5 10 0.8 13 152 0.08 10 lip FC-5 OFFICE 15 2 NW OFFICE 122 0.06 5 0.6 5 10 0.8 13 156 0.08 1.0 7.0 1.0 10 106 FC-5 L t 3 'Zy v OFFICE 16 2 NW OFFICE 122 0.06 5 0.6 5 10 0.8 13 156 0.08 10 q<YMJ WFC OPEN OFFICE 2 NW OFFICE 633 0.06 5 3.2 5 54 0.8 67 810 0.08 54 EXPIRES: 06/30/2020 TOTALS: 1,250 7 106 133 1,600 106 OFFICE 17 2 NE OFFICE 151 0.06 5 0.8 5 13 0.8 16 208 0.08 12 OFFICE 18 2 NE OFFICE 218 0.06 5 1.1 5 19 0.8 23 300 0.08 18 FC-6 OPEN OFFICE 2 NE OFFICE 524 0.06 5 2.6 5 45 0.8 56 722 0.08 1.0 5.0 0.8 42 94 FC 6 BREAK ROOM 2 NE OFFICE 269 0.06 5 1.3 5 23 0.8 29 370 0.08 22 _ TOTALS: 1,162 6 99 123 1,600 94 OFFICE 7 2 SW OFFICE 181 006 5 0.9 5 15 0.8 19 238 0.08 15 OFFICE 8 2 SW OFFICE 186 0.06 5 0.9 5 16 0.8 20 245 0.08 16 OFFICE 9 2 SW OFFICE 140 0.06 5 0.7 5 12 0.8 15 184 0.08 12 OFFICE 10 2 SW OFFICE 142 0.06 _ 5 0.7 5 12 0.8 15 187 0.08 12 FC-7 OFFICE 'i 1 2 SW OFFICE 111 0.06 5 0.6 5 9 0.8 12 146 0.08 1.0 4.0 1.0 9 99 CD FC-7 OFFICE 19 2 SW OFFICE 145 0.06 5 0.7 5 12 0.8 15 191 0.08 12 OFFICE 20 2 SW OFFICE 135 0.06 5 0.7 5 11 0.8 14 177 1 0.08 11 CIRC 2 SW CORRIDOR 177 0.06 0 0.0 0 0 0.8 0 233 0.00 11 TOTALS: 1,217 4 88 111 1,600 99 Q IT ROOM 2 SE OFFICE 78 0.06 5 0.4 5 7 0.8 8 180 0.05 8 COPY ROOM 2 SE OFFICE 96 0.06 5 0.5 5 8 0.8 10 200 0.05 8 48 50 J OPEN OFFICE 2 SE OFFICE 172 0.06 5 0.9 5 15 0.8 18 460 0.04 14 uu FC-8 CONF. RM. 2 SE CONFERENCE 223 0.06 50 11.2 5 69 0.8 86 500 0.17 0.9 11.0 0.8 57 98 FC-8 STOR. 2 SE WAREHOUSE 57 0.06 10 0.6 0 3 0.8 4 120 0.04 3 Z TOILET ROOM 2 SE TOILET ROOM 65 0 0 0.0 0 0 0.8 0 70 0.00 0 80 80 M TOILET ROOM 2 SE TOILET ROOM 70 0 0 0.0 0 0 0.8 0 70 0.00 0 1 80 1 80 W ----- ---- Lu Lu - TOTALS: 761 14 102 127 1,600 88 NOTES: Q Q 1 MECHANICAL OSA CALCULATION PER GMSC 403.3 Q � � FAN COIL UNITS - (HEATING & COOLING) 0 Cy Lu NOMINAL SENSIBLE HEATING FLOW AUX. ELECTRIC HEATER ELECTRICAL OPER. W OUTDOOR CAPACITY CAPACITY CAPACITY ESP Fm SYMBOL QTY UNIT MANF. MODEL AREA SERVED LOCATION SUPPLY OSA VOLTS/ POWER VOLTS/ FLA WEIGHT NOTES 7080 SW FIR LOOP FCU-1 1 HP-1 CARRIER FB4CNP048L00 IST FLOOR NW 1ST FL CLOSET 4.0 34.6 45.6 1,600 90 0.5 208/1 15.0 208/1 6 157 1, 2 TIGARD. OR QFCU-2 1 HP-2 CARRIER FB4CNP048L00 1ST FLOOR NE 1ST FL CLOSET 4.0 34.6 45.6 1,600 105 0.5 208/1 15.0 208/ 1 6 157 1, 2 1 FCU-3 1 HP-3 CARRIER FB4CNP048L00 1ST FLOOR SW 1ST FL CLOSET 4.0 34.6 45.6 1,600 185 0.5 208/1 15.0 208/1 6 157 1, 2 FCU-4 1 HP-4 CARRIER FB4CNP048L00 1ST FLOOR SE 1ST FL CLOSET 4.0 34.6 45.6 1,600 115 0.5 208/1 15.0 208/1 6 157 1, 2 FCU-5 5 A I o REVISIONS FCU-6 1 HP-6 CARRIER FB4CNP048L00 2ND FLOOR NE ATTIC 4.0 34.6 45.6 1,600 100 0.5 208/1 15.0 208/1 6 157 1, 2 FCU-7 1 HP-7 CARRIER FB4CNP048L00 2ND FLOOR SW ATTIC 4.0 34.6 45.6 1,600 100 0.5 208/1 15.0 208/ 1 6 157 1, 2 FCU-8 1 HP-8 CARRIER FB4CNP048L00 2ND FLOOR SE ATTIC 4.0 34.6 45.6 1,600 100 0.5 208/1 1 15.0 208/1 6 157 1, 2- 1 SCHEDULES 2/17/2020 c 0 (n NOTES: F- 1. PROVIDE CONDENSATE PUMP N 2. PROVIDE WITH SINGLE POINT POWER CONNECTION Q 0 t 3 c a HEAT PUMPS - AIR COOLED 0 NOMINAL HEATING EFFICIENCY ELECTRICAL OPER. DATE 12/18/2019 REFER. a��i SYMBOL QTY, INDOOR MANF. MODEL LOCATION CAPACITY CAPACITY CLG. HTG. VOLTS/ MCA MOCP SPE WEIGHT NOTES UNITo (TONS) (MBH) (SEER) (HSPF) PHASE (AMPS) (AMPS) (LBS.) DRAWN BY STC HP-1 1 FCU-1 CARRIER 25HCE448AO05 ROOF 4.0 45.6 14.0 8.2 208/3 14.5 25 R410A 197 1 CHECKED BY TW L HP-2 1 FCU-2 CARRIER 25HCE448AO05 ROOF 4.0 45.6 14 8.2 208/3 14.5 25 R410A 197 1 0 o HP-3 1 FCU-3 CARRIER 25HCE448AO05 ROOF 4.0 45.6 14 8.2 208/3 14.5 25 R410A 197 1 MECHANICAL c co :HP-6 1 FCU-5 CARRIER 25HCE448AO05 ROOF 4.0 45.6 14 8.2 208/3 14.5 25 R410A 197 1 SCHEDULES Q 1 FCU-6 CARRIER 25HCE448AO05 ROOF 4.0 45.6 14 8.2 208/3 14.5 25 R410A 197 1 1 FCU-7 CARRIER 25HCE44BA005 ROOF 4.0 45.6 14 8.2 208/3 14.5 25 R410A 197 1 1 FCU-8 CARRIER 25HCE44BA005 ROOF 4.0' 45.6 14 8.2 208/3 14.5 25 R410A 197 1 cn co M001 0 NOTES: PERMIT 0 DRAWING HVAC/R - CON CONTRACTORS - ENGINEERS SERVICE " MAINTENANCE (503) 234-0477 • hunterdavisson.com REO PR 041 PE\\ �M7EGONo1 13 ,Z 5 EXPIRES: 06/30/2020 I I ADJACENt OFFICE U I 2260 SF I II CONNECT TO B I EXIST DUCTWORK. I I 1 I SUPPLY AND I ADA I I Z AND RETURN DUCTS STRO -M- -- ----------- - ------- -- ® Z R UTE REFRIGERAV I I 18"0 SUPPLY ( J PIPING TO ROPF - I AND RETURN I W i AN CONDENSATE 'TO FC 3 FCf I DUCTS APPROVED DRAIN OCATION. (TYP tLj I � Z FC-1I I I I r �' I OFFIOFFI i WORK I�IECH . /ELEC. 6 F ROOM 0 O a BAR 18"0 SUPPLY a AND RETURN \ �_ .- - - ------ - ' _ DUCTS -- - -� ` - - --- -- 0 Q a. gg cy Lu FC-2 " 0 FFI CE I CONNECT TO EXIST DUCTWORK. �mm W T r A : _- OFFI C 7080 SW FIR LOOP 5 I TIGARD, OR DUCTWORK.O EXIST FRO ,T T I 3 4 I I REVISIONS 1 LAYOUT 2/17/2020 c O I I I I I in E I BUILDING ENTRY 77 3 0 0 U ----'j ------- -- -- --------------------y- - 1 -- ® LEGEND: o I I I I DATE 12/18/2019 CL Q DEMO © ® © DRAWN BY STC 0 c0 CAP CHECKED BY TW 0 Q RELOCATE LEVEL ONE 0o ON NEW FLOOR PLAN 0 N 0 CONNECT TO EXISTING cLEVEL ONE FLOOR PLAN M 101 0 cu 1 1/8" = V-0m PERMIT 0 DRAWING OA HVAC/R • CONTROLS CONTRACTORS - ENGINEERS SERVICE • MAINTENANCE (503) 234-0477 • hunterdavisson.com 1 �p PR 1 N Lu NtvE Z cC ,�\ r v REGON 13 .y0 c� 4 1 — © EXPIRES: 06/30/ 0 FFICE FFICE OFFICE OFFICE DN 202 4 5 16 17 II 111111 FC-5 T ON OP N OFFICE OFFI CE OFFICE 1 13 i I I T FC-6 I Z --- ---- - -- - --- ---- ----------- -T-- ® o Z OFFICE 8"o OA DUCT FROM I B AK I W ATTIC DOWN TO CEILING 1 2 OF FIRST FLOOR (TYP 4) Q1 ONF Z 2 Im W uJ OFFICE 1 � _ 1 OltFICE 19 RM 2� I II It aa ---- --- - - - - — -- ---- �- -- — J 1 I I I CIRC. cy Lu OFF E 1 ST R I ~ W w 10 FC-7 T N7080 SW FIR LOOP 0 E� 0 I TIGARD, OR OF ICS c-8 1 OFFICE OFFICE OFFICE CONE. 10 °N I REVISIONS 9 8 7 RM . 1 ( VIII 1 OA DUCT AND 2/17/2020 c - ---� --_L.6. h - - -- ® T-STAT TAGS p CD E 1 I I I I O a) 7 O L_ 3 0 __— _—_---_—I_— _—_—_— ® LEGEND: o I I I I DATE 12/18/2019 Q DEMO ® ® © DRAWN BY STC L O o a) Oc CAP CHECKED BY TW Q RELOCATE LEVEL TWO 0 C6 NEW FLOOR PLAN I 0 CONNECT TO EXISTING cLEVEL TWO FLOOR PLAN M102 O cn w 1 1/8" = 1. PERMIT 0 DRAWING 1111 . HVAC/R • CONTROLS CONTRACTORS • ENGINEERS SERVICE • MAINTENANCE (503) 234-0477 • hunterdavisson.com PR w � IN yy'' PE �NOREGONo v ci EXPIRES: 06/30/2020 CONNECT TO EXISTING SUPPLY AND RETURN DUCTWORK IN ATTIC (TYP 4) 18"0 SUPPLY AND RETURN (TYP 4)' HP-5 E ® Z ' FC-5 ❑ FC-6 � HP-1 HP-2 • Z J W SEE STRUCTURAL/ FJ� 8"0 FRESH AIR MOUNT NEW HEAT F SIESMIC CALCULATION INTAKES WITH BIRD PUMPS ON EXISTING PACKAGE FOR UNIT O--O Fi�— SCREEN (TYP 8) EQUIPMENT PLATFORMS MOUNTING DETAILS. (TYP 8) Lu Lu HP-4 � O E U FC-7 FC-8 i � a Lu Lu W 7080 SW FIR LOOP TIGARD, OR REVISIONS 1 LAYOUT 02/17/2020 c 0 w E L C Q _ O L Y 3 c 0 w U a LEGEND: DATE 12/18/2019 QX DEMO o DRAWN BY STC 0; Qc CAP CHECKED BY TW _ Q RELOCATE 0 ROOF PLAN 0 0" NEW I 0 N CONNECT TO c EXISTING 0 N ROOF PLAN M103 0 m PERMIT o DRAWING 17TAR 641604101 HVAC/R • CONTROLS CONTRACTORS • ENGINEERS SERVICE • MAINTENANCE (503) 234-0477 • hunterdavisson.com RFD PR IMpE. , Z -_-- �_-- _ -_-- -�- - 1 © EGON ADJACENT I I ` 13 2015 ' OFFICE �j TENANT I ' EXPIRES: 06/30/2020 J I -- - -- - -_ ---- 2260 SF I II B DEMO EXIST FAN COIL r------i r---- AND THERMOSTATS. REUSE DUCT AND L______J REFRIGERANT PIPING. ADA I (TYP 4) I _ DEMO EXIST RTUS ESTROOM I (' --- - -------- -----------+------- - - -- --- - -- --r-- ® L-----J Z DEM EXIST r— PUMPS i 1 HEAT II L_J L_J Q Z _ W OFFICE OFFIjE WORK ECH . /ELEC. � 1 0 6 ROOM W W BAR - - —-—- --- - - - V I o OFFICE CIRC. Qom J 2 -----, I ------ I OFFICE cy Lu L----- - --- 5 I Lu FR0 T ' OFFICE CONFERENCE OFFICE OFFI E 7080 SW FIR LOOP 3 4 I I TIGARD, OR I ' U ' ----�--- -- ----- - f - -- ® I I I REVISIONS BUILDING ENTRY E , I a I w 0 ---- - .. L 3 o © ® ® Q U 7 o DATE 12/18/2019 o_ DRAWN BY STC 0 0 CHECKED BY TW LEGEND: LEVEL ONE FLOOR PLAN — DEMO 2 ROOF PLAN — DEMO DEMO PLANS oQ DEMO � _ 11-0 �/6� - -0• N Qc CAP in Q RELOCATE MD101 0 0" NEW CONNECT TO PERMIT = EXISTING o DRAWING