Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (16)
M EC2020-00046 ( 1/2 ) OFFICE COPY GENERAL NOTES ABBREVIATIONS 1. MECHANICAL WORK COMPLIES WITH THE 2019 OREGON ZERO ENERGY READY COMMERCIAL CODE,ASHRAE 90.12016, 2019 OREGON A/C AIR CONDITION(ED) CD CONDENSATE DRAIN EQUIP EQUIPMENT IN INCHES OSA OUTSIDE AIR TYP TYPICAL STRUCTURAL SPECIALTY CODE AND THE 2019 OREGON MECHANICAL SPECIALTY CODE INCLUDING APPENDIX C-FUEL GAS. AD ACCESS DOOR CFM CUBIC FEET PER MINUTE ERV ENERGY RECOVERY VENTILATOR LAT LEAVING AIR TEMPERATURE PSI POUNDS PER SQUARE INCH V VOLT AFF ABOVE FINISHED FLOOR CLG CEILING ESP EXTERNAL STATIC PRESSURE LF LINEAR FEET QTY QUANTITY VD VOLUME DAMPER(HAND OPERATOR) 2. WORK INCLUDES AN ALTERATION OF AN EXISTING BUILDING. ALT ALTERNATIVE CND CONDENSATE DRAIN EXH EXHAUST MA MIXED AIR RA RETURN AIR VFD VARIABLE FREQUENCY DRIVE AL ALUMINUM CONIC CONCRETE EXIST EXISTING MAX MAXIMUM RET RETURN VRV VARIABLE REFRIGERANT VOLUME APD AIR PRESSURE DROP CONT CONTINUE(D)(ATION) EXP EXPANSION MBH THOUSAND BTU PER HOUR REV REVISION W/ WITH 3. MECHANICAL EQUIPMENT BEING REPLACED COMPLIES WITH APPLICABLE REQUIREMENTS OF THE NEW CODE.ASHRAE 90.1-6.1.1.3.1 APPROX APPROXIMATELY CL CENTERLINE F DEGREES FAHRENHEIT MD MOTORIZED DAMPER RH RELATIVE HUMIDITY WB WET BULB ARCH ARCHITECT(URAL) DDC DIRECT DIGITAL CONTROL FC FLEXIBLE CONNECTOR MECH MECHANICAL RPM REVOLUTIONS PER MINUTE WC WATER COLUMN 4. THE'SIMPLIFIED APPROACH'TO COMPLIANCE WITH ASHRAE 90.1 IS USED. THE BUILDING IS TWO STORIES TALL OR LESS AND HAS A GROSS AUTO AUTOMATIC DEFL DEFLECTION FD FIRE DAMPER MFG MANUFACTURER SASUPPLY AIR W/o WITHOUT AREA LESS THAN 25,000 SQUARE FEET. HVAC SYSTEMS ARE SINGLE ZONE SYSTEMS. BDD BACKDRAFT DAMPER DN DOWN FPM FEET PER MINUTE MH MOUNTING HEIGHT SF SQUARE FEET WPD WATER PRESSURE DROP ����'` , D BHP BRAKE HORSE POWER DWG DRAWING FSO FIRE SMOKE DAMPER MIN MINIMUM SH SENSIBLE HEAT W WATT BLDG BUILDING EAT ENTERING AIR TEMPERATURE FT FEET N/A NOT APPLICABLE SP STATIC PRESSURE KW KILOWATT V 5. COOLING EFFICIENCY OF UNITS COMPLIES WITH TABLES 6.8.1-1,6.8.1-2 OR 6.8.1-4. BOD BOTTOM OF DUCT EF EXHAUST FAN FV FACE VELOCITY NC NOISE CRITERIA SPEC SPECIFICATION JAN 21 T 0 HVAC/R • CONTROLS BOP BOTTOM OF PIPE EFF EFFICIENCY GA GAGE/GAUGE NC NORMALLY CLOSED SS STAINLESS STEEL 6. INSTALL HEATING EQUIPMENT THAT MEET THE MINIMUM EFFICIENCIES REQUIREMENTS OF ASHRAE 90.1 TABLES 6.8.1-2,6.8.1-4,6.8.1-5 AND BSMT BASEMENT ELEC ELECTRIC(AL) GALV GALVANIZED NC NORMALLY OPEN TD TEMPERATURE DIFFERENCE CITY OF TIGARD CONTRACTORS • ENGINEERS 6.8.1-6. BTUH BRITISH THERMAL UNIT PER HOUR ELEV ELEVATION HP HORSE POWER NTS NOT TO SCALE TEMP TEMPERATURE BUILDING DIV SION CD CEILING DIFFUSER EQ EQUAL ID INTERNAL DIAMETER OD OUTSIDE DIAMETER TP TOTALPRESSURE SERVICE • MAINTENANCE 7 IES SN (ASHRAE 90.1 TABLE 6 OPERTHAN ATE 1) 8000 HOURS PER YEAR;THEREFORE NO EXHAUST ENERGY RECOVERY SYSTEM IS INCLUDED IN THEDESIGN HVAC DUCT SYMBOLS 8. INSTALL MANUAL CHANGEOVER OR DUAL SET-POINT THERMOSTATS. FITTING SINGLE LINE DOUBLE LINE FITTING SINGLE LINE DOUBLE LINE FITTING SINGLE LINE DOUBLE LINE SINGLE LINE ITEM TAG 503 234-0477 • hunterdavisson.com VOLUME DAMPER CONCENTRIC NON-SYMMETRICAL so°TRANSITIo SUPPLY AIR ® ® FAN COIL UNIT rc AN colo rrpe SQUARE TO ROUNDFO W VE OUTSIDE AIR FLOOR-,.,-FAN COIL NUMBER ION FLOOR)wv-, 9. INCLUDE INTERNAL SUPPLEMENTAL ELECTRIC RESISTANCE HEATERS IN HEAT PUMPS. LIMIT SUPPLEMENTAL HEATER OPERATION TO COMPLY I�pFD , 15°MAX WITH ASHRAE 90.1-6.3.2(h). FIRE DAMPER r 1 r CONCENTRIC DOUBLE FORMED , RETURN AIR VRV SYSTEM vRv rvuMaeR)srsreM) 1�--f ROUNDTRANSITIONTURNING VANES 15°MA% EXHAUST AIR EFEas TO Mev SYSTEM 90°RECTANGULAR RECTANGULAR �-� ® ® FAN COIL UNIT Fc-u, uv COIL NUMBER �F,O PR ELBOW WITH ECCENTRIC {I�y..�L `-'-'� 10. INSTALL A SEVEN DAY TIME CLOCK FOR EACH SYSTEM HAVING COOLING R HEATING CAPACITY GREATER THAN TEM U BTU/H AND A FAN TURNING VANES ''� (RECTANGULAR r�� ��15 MA% DUCT RISER ROOM THERMOSTAT REFERS TO VRV SYSTEM - (N BRANCH POWER GREATER THAN 7.5 HP. PROVIDE CONTROLS THAT CAN BE PROGRAMMED TO START AND STOP THE SYSTEM UNDER DIFFERENT OR ROUND) ROUND �-� ® AC-1-UNIT CONTROLLED es-,., aRnrvcN SELEcroRNUMBER GJ lX, ;. \� f' SCHEDULES FOR SEVEN DIFFERENT DAY TYPES PER WEEK,THAT WILL RETAIN PROGRAMMING FOR 10 HOURS DURING A:OSS OF POWER,AND R=W DUCT RISER SELECTOR + Z EXTRACTOR CONNECTION Slg 0 DIFFUSER, THAT HAVE A TWO HOUR MANUAL OVERRIDE.CONFIGURE SETBACK HEATING SET-POINT TO 55 F AND SETUP COOLING SET-POINT TO 90 F RADIUS ELBOW Ex RECTANGULAR �{-� TYRE W \�pr� �E' ' a yV EX DUCT DROP REGISTER w Tree-rrRlcu a r "`V L`\ r DURING UNOCCUPIED HOURS. RouN d GRILLE FM \AD.IIF0.J1ftl DUCT ROUND -I---� ® CONNECTION I( EGON e, RECTANGULAR y ROUND MAIN DUCT DROP 511E LOT NUMBER a SLOT SRP ` ON, MAIN WITH LINEAR SLOT o an -, -TYRE 11. INSULATE HVAC PIPING TO MEET THE REQUIREMENTS OF TABLES 6.8.3-1,AND 6.8.3-2. PROTECT OUTDOOR PIPING INSULATION FROM RECTANGULAR DUCT WITH ONICAL ROUND RECTANGULAR DIFFUSER Rs-Trp¢u 13 , G) DAMAGE. BRANCH J, 4 6" ROUND BRANCH TEE BRANCH OFFSET>15' FM q�y�•• Vv 12. INSULATE DUCTWORK TO MEET THE REQUIREMENTS OF TABLE 6.8.2.CONSTRUCT DUCTWORK AND PLENUMS TO SEAL CLASS A. SEALALL EXPIRES: 06/30/2020 CONNECTIONS(EXCEPT SPIRAL DUCT CONNECTIONS). DESIGN CONDITIONS - PORTLAND, OREGON SHEET INDEX 13. AIR-BALANCE DUCTED SYSTEMS IN ACCORDANCE WITH INDUSTRY STANDARDS. SPACE WINTER SUMMER SHEET SHEET REV REV 14. DESIGN MINIMUM OUTDOOR AIR CFM DOES NOT EXCEED 135%OF THE MINIMUM OUTSIDE AIR REQUIRED BY THE GMSC. TEMPERATURE HUMIDITY TEMPERATURE HUMIDITY # NAME # DATE INDOOR 70°F f 2°F DB NOT CONTROLLED 75°F t 2°F DB NOT CONTROLLED M000 MECHANICAL COVER PAGE 15. PREVENT SIMULTANEOUS HEATING AND COOLING WITH ZONE CONTROLS. OUTDOOR 25.2°F DB N/A 91.4°F DB/67.3°F MCWB 28.1% RH M001 MECHANICAL SCHEDULES 16. UNLESS OTHERWISE INDICATED,DOORS TO OUTSIDE ARE PROVIDED WITH AUTOMATIC DOOR CLOSERS OR ARE LOCATED IN SPACES WITHOUT NOTES: MD101 DEMO PLANS THERMOSTATS. DOOR SWITCHES FOR HVAC CONTROL ARE NOT REQUIRED. 1. OUTDOOR CONDITIONS BASED ON ASHRAE FUNDAMENTALS 2013, 99.6% 8+0.4% DATA M101 LEVEL ONE FLOOR PLAN CD M102 LEVEL TWO FLOOR PLAN M103 ROOF PLAN MINIMUM INSULATION R-VALUE FOR HVAC DUCT SYSTEMS (OREGON) z DUCT LOCATION DUCT TYPE a Z OUTSIDE RETURN COOLING HEATING AIR AIR SUPPLY SUPPLY SCOPE OF WORK: LuLu EXTERIOR OF BUILDING (1) 8.0 8.0 6.0 UNCONDITIONED SPACES (2) 8.0 6.0 6.0 1. DEMO AND F ECYCLE EXISTING ROOFTOP AIR CONDITIONERS AND CONDENSING INDIRECTLY CONDITIONED SPACES (RETURN AIR PLENUMS) - - 1.9 1.9 UNITS. Uj LU FULLY CONDITIONED SPACES 2. DEMO AND RECYCLE EXISTING CEILING MOUNTED FAN COIL UNITS ON FIRST FLOOR. Q NOTES: 3. FURNISH AND INSTALL(X4) NEW ROOFTOP HEAT PUMPS WITH SUPPLEMENTAL THIS TABLE IS IN ACCORDANCE WITH ASHRAE 90.1 2016 TABLE 6.8.2. ELECTRIC HEATERS, 1. INCLUDES ATTICS ABOVE INSULATED CEILINGS, PARKING GARAGES AND CRAWL SPACES 2. INCLUDES UNCONDITIONED, UNVENTED SPACES SUCH AS UNVENTED MECH. ROOMS, SHAFTS, OR PLENUMS IN THE BUILDING 4. FURNISH AND INSTALL(X4) NEW FAN COIL UNITS ON FIRST FLOOR AND (X4) NEW SPLIT-SYSTEM HEAT PUMPS ON ROOF. ENVELOPE 3. RUNOUTS TO TERMINALS OR OUTLETS DO NOT REQUIRE MORE THAN R-3.5 INSULATION. 5. CLEAN, PURGE AND REUSE REFRIGERANT PIPING FROM NEW FAN COILS TO om OR PLENUM DOES NOT EXCEED 15°F CONNECT TO NEW SPLIT-SYSTEM HEAT PUMPS. REPAIR INSULATION AS REQUIRED. Cy Lu OWENS CORNING SOFT-R DUCTWRAP FRK WITH A THICKNESS OF 2.2" HAS AN INSTALLED RATING OF R-6.0 OWENS CORNING SOFT-R DUCTWRAP FRK WITH A THICKNESS OF 3" HAS AN INSTALLED RATING OF R-8.3 6. FURNISH AND INSTALL SUPPLY AND RETURN DUCT WORK TRANSITIONS FROM NEW UNITS TO EXISTING DUCTWORK. uj 7. FURNISH AND INSTALL NEW CONDENSATE DRAINS FROM ROOFTOP UNITS TO ROOF. 8. CONNECT NEW FAN COILS TO EXISTING CONDENSATE DRAINAGE. 7080 SW FIR LOOP TIGARD, OR 9. FURNISH AND INSTALL (X8) NEW 7-DAY PROGRAMMABLE THERMOSTATS FOR SPLIT-SYSTEMS AND ROOFTOP HEAT PUMPS. OFFICE COPY 10. START, CHECK AND ADJUST SYSTEMS CITY OF TIGARD REVISIONS REVIEWED FOR CODE COMPLIANCE ApprovcdIi'� OTC: 0 [ ] AREA OF WORK: Permit#: alp C a n An - nog E Address: 7n 4n cam. F :r Loo C (D urtc Q By; Date: o L .3 c O SIP;Vans t;t SN!Valns S[ SW Yarns S( U 7 0 VALIDITY OF PERMIT DATE 12/18/2019 CL THE ISSUANCE A PERMIT BASED ON CONOSTRUCTION DRAWN BY STC 0 DOCUMENTS AND OTHER N THE CODE OFFOICIAATA SHALL L FEVENT ROM cn CHECKED BY TW a OF RE (ERRORS.OSOSC 105.4 MECHANICAL o 06 c x'09°;°Nlh,ve5)Fir Loop COVER PAGE 0 N U C C o CITY OF TIGARD M000 c Approved by Planning Date: I-1 �'�� PERMIT o Initials: DRAWING I N G �� MECHANICAL OSA CALCULATIONS FLOOR OUTDOOR AIR OCCUPANT NUMBER OF OUTDOOR AIR PER BREATHING EFFECTIVENESS, ZONE OSA, ZONE AIRFLOW, ZONE OSA SYSTEM VENT. SYSTEM OCCUPANT UNCORRECTED MINIMUM OUTSIDE EXHAUST SYSTEM ROOM NAME ZONE SPACE TYPE AREA, Az PER AREA, Ra DENSITY OCCUPANTS, PERSON, Rp ZONE, Vbz EZ VOz VPZ FRACTION, ZP EFFICIENCY, Ev POPULATION, Ps DIVERISTY, D OUTSIDE AIR, Vou AIR, VOr FRESH AIR NOTES REQUIRED DESIGNED SOURCE [SF] [CFM/SF] [#/1000 SF] Pz [CFM/PERSON] [CFM] (_) (CFM] [CFM] (_) (CFM] (_) (_) (CFM] (CFM] (CFM] (CFM] ADJACENT OFFICE 1 NW OFFICE 1,034 0.06 5 5.2 5 88 0.8 110 1,097 0.10 88 OFFICE 1 1 NW OFFICE 274 0.06 5 1.4 5 23 0.8 29 291 0.10 23 FC-1 OFFICE 6 1 NW OFFICE 148 0.06 5 0.7 5 13 0.8 16 157 0.10 1.0 8.0 1.0 13 124 FC-1 RESTROOM 1 NW TOILET ROOM 1 52 1 0 1 0 0 5 0 0.8 0 55 0.00 0 70 70 TOTALS: 1,508 8 124 155 1,600 124 ADJACENT OFFICE INE OFFICE 1,222 0.06 5 6.1 5 104 0.8 130 1,280 0.10 104 FC-2 WORKROOM 1 NE WORKROOM 305 0.06 4 1.2 5 24 0.8 31 320 0.10 1.0 8.0 1.0 24 128 FC-2 HVAC/R • CONTROLS TOTALS: 1,527 8 128 160 1,600 128 OFFICE 1 SW OFFICE 188 0.06 5 0.9 5 16 0.8 20 322 0.06 15 CONTRACTORS • ENGINEERS OFFICE 3 1 SW OFFICE 115 0.06 5 0.6 1 5 10 0.8 12 197 0.06 9 FC-3 CONFERENCE RM 1 SW CONFERENCE 343 0.06 50 17.2 5 106 0.8 133 587 0.23 0.9 17.0 0.9 97 157 FC-3 SERVICE • MAINTENANCE BAR 1 SW OFFICE 57 0.06 5 0.3 5 5 0.8 6 98 0.06 5 CORRIDOR 1 SW CORRIDOR 232 0.06 0 0.0 0 14 0.8 17 397 0.04 14 TOTALS: 935 19 151 189 1,600 141 OFFICE 4 1 SE OFFICE 150 0.06 5 0.8 5 13 0.8 16 201 0.08 12 - (503) 234-0477 • hunterdavisson.com CIRC 1 SE CORRIDOR 317 0.06 0 0.0 0 19 0.8 24 424 0.06 19 FC-4 FRONT OFFICE 1 SE OFFICE 137 0.06 5 0.7 5 12 0.8 15 183 0.08 1.0 5.0 0.8 11 96 FC-4 BUILDING ENTRY 1 SE ENTRY LOBBY 288 0.06 10 2.9 5 32 0.8 40 385 0.10 29 OFFICE 5 1 SE OFFICE 50.06 5 1..5 5 266 101 0 126 1 6 8 32 8 0.08 6 9 TOTALS: 1,1197 OFFICE 12 2 NW OFFICE 103 0.06 5 0.5 5 9 0.8 11 132 0.08 9 gy OFFICE 13 2 NW OFFICE 151 0.06 5 0.8 5 13 0.8 16 193 0.08 13 .j ,l'\1 1\ RTU-1 OFFICE 14 2 NW OFFICE 119 0.06 5 0.6 5 10 0.8 13 152 0.08 1.0 7.0 1.0 106 RTU-1 10 EGON ,ey OFFICE 15 2 NW OFFICE 122 0.06 5 0.6 5 10 0.8 13 156 0.08 10 OFFICE 16 2 NW OFFICE 122 0.06 5 0.6 5 10 0.8 13 156 0.08 10 13 , OPEN OFFICE 2 NW OFFICE 633 0.06 5 3.2 5 54 0.8 67 810 0.08 54 TOTALS: 1,250 7 106 133 1,600 106 EXPIRES: 06/30/2020 OFFICE 17 2 NE OFFICE 151 0.06 5 0.8 5 13 0.8 16 208 0.08 12 RTU-2 OFFICE 18 2 NE OFFICE 218 0.06 5 1.1 5 19 0.8 23 300 0.08 10 50 08 18 94 RTU-2 OPEN OFFICE 2 NE OFFICE 524 0.06 5 2.6 5 45 0.8 56 722 0.08 . . . 42 BREAK ROOM 2 NE OFFICE 269 0.06 5 1.3 5 23 0.8 29 370 0.08 22 TOTALS: 1,162 6 99 123 1,600 94 OFFICE 7 2 SW OFFICE 181 0.06 5 0.9 5 15 0.8 19 238 0.08 15 OFFICE 8 2 SW OFFICE 186 0.06 5 0.9 5 16 0.8 20 245 0.08 16 OFFICE 9 2 SW OFFICE 140 0.06 5 0.7 5 12 0.8 15 184 0.08 12 RTU-3 OFFICE 10 2 SW OFFICE 142 0.06 5 0.7 5 12 0.8 15 187 0.08 12 1.0 4.0 1.0 99 RTU-3 OFFICE 11 2 SW OFFICE 111 0.06 5 0.6 5 9 0.8 12 146 0.08 9 OFFICE 19 2 SW OFFICE 145 0.06 5 0.7 5 12 0.8 15 191 0.08 12 OFFICE 20 2 SW OFFICE 135 1 0.06 5 0.7 5 11 1 0.8 1 14 1 177 1 0.08 11 CIRC 2 SW CORRIDOR 177 0.06 0 0.0 0 0 0.8 0 233 0.00 11 TOTALS: 1,217 4 88 111 1,600 99 Fm IT ROOM 2 SE OFFICE 78 0.06 5 0.4 5 7 0.8 8 164 0.05 6 Q COPY ROOM 2 SE OFFICE 96 0.06 5 0.5 5 8 0.8 10 202 0.05 8 48 50 OPEN OFFICE 2 SE OFFICE 172 0.06 5 0.9 5 15 0.8 18 362 0.05 14 RTU-4 CONF. RM. 2 SE CONFERENCE 223 0.06 50 11.2 5 69 0.8 86 469 0.18 0.9 11.0 0.8 57 98 RTU-4 Lu STOR. 2 SE WAREHOUSE 57 0.06 10 0.6 0 3 0.8 4 120 0.04 3 TOILET ROOM 2 SE TOILET ROOM 65 0 0 0.0 0 0 0.8 0 137 0.00 0 70 70 Z TOILET ROOM 2 SE TOILET ROOM 1 70 0 0 0.0 0 0 0.8 0 147 0.00 1 0 1 1 70 1 70 TOTALS: 761 1 14 102 127 1,600 88 Lu uj NOTES: 1. MECHANICAL OSA CALCULATION PER OMSC 403.3 Q 2 U NITS a Q PACKAGED ROOFTOP U - J NOMINAL SENSIBLE HEATING EFFICIENCY AIRFLOW ELECTRICAL OPER. a. ESP REFER. SYMBOL QTY. MANF. MODEL AREA SERVED DISCHARGE CAPACITY CAPACITY INPUT CLG. HTG. SUPPLY OSA VOLTS/ MCA MOCP BHP HP TYPEPE WEIGHT NOTES uj (TONS) (MBH) (MBH) (SEER) (HSPF) (CFM) (CFM) (IN WG) PHASE (AMPS) (AMPS) (LBS.) RTU-1 1 CARRIER 50KCQA05A2A5 2ND FLOOR NW HORIZONTAL 4.0 36.7 4.3 14 8.0 1,600 100 0.5 208/3 66 70 .66 3/4 R410A 630 1,2 RTU-2 1 CARRIER 50KCQA05A2A5 2ND FLOOR NE HORIZONTAL 4.0 36.7 4.31 14 8.0 1,600 100 0.5 208/3 66 70 .66 3/4 R410A 630 1,2 RTU-3 1 CARRIER I 50KCQA05A2A5 2ND FLOOR SW HORIZONTAL 4.0 36.7 4.31 14 8.0 1,600 100 0.5 208/3 66 70 .66 3/4 R410A 630 1,2 7080 SW FIR LOOP RTU-4 1 CARRIER SOKCQA05A2A5 2ND FLOOR SE HORIZONTAL 4.0 36.7 4.31 14 8.0 1,600 100 0.5 208/3 66 70 .66 3/4 R410A 630 1,2 - TIGARD, OR NOTES: 1. PROVIDE HEAT PUMP WITH SUPPLEMENTAL 208/3/60 12 KW ELECTRIC HEATER 2. PROVIDE WITH MANUAL OSA HOOD REVISIONS FAN COIL UNITS - (HEATING & COOLING) u`n NOMINAL SENSIBLE HEATING FLOW AUX. ELECTRIC HEATER ELECTRICAL OPER. OUTDOOR CAPACITY CAPACITY CAPACITY ESP 0 SYMBOL QTY UNIT MANE MODEL AREA SERVED LOCATION SUPPLY OSA VOLTS/ POWER VOLTS/ FLA WEIGHT NOTES (TONS) (MBH) (MBH) (CFM) (CFM) (IN WG) PHASE (KIM PHASE (AMPS) (LBS.) 0 FCU-1 1 HP-1 CARRIER FB4CNP048L00 1ST FLOOR NW 1ST FLOOR CLG 4.0 34.6 45.6 1,600 125 0.5 208/1 15.0 208/ 1 6 157 1, 2 3 FCU-2 1 HP-1 CARRIER FB4CNP048L00 1ST FLOOR NE 1ST FLOOR CLG 4.0 34.6 45.6 1,600 130 0.5 208/1 15.0 208/1 6 157 1, 2 c FCU-3 1 HP-1 CARRIER FB4CNP048L00 1ST FLOOR SW 1ST FLOOR CLG 4.0 34.6 45.6 1 1,600 160 0.5 208/1 15.0 208/1 6__L 157 1 1, 2 0 FCU-4 1 HP-1 CARRIER FB4CNP048L00 1ST FLOOR SE 1ST FLOOR CLG 4.0 34.6 45.6 1,600 100 0.5 20811 1 15.0 208/1 6 157 1, 2 U 0 NOTES: 12/18/2019 Q 1. PROVIDE CONDENSATE PUMP DATE 2. PROVIDE WITH SINGLE POINT POWER CONNECTION L DRAWN BY STC 0 3 CHECKED BY TW HEAT PUMPS - AIR COOLED 0 MECHANICAL oc NOMINAL HEATING EFFICIENCY ELECTRICAL OPER. SYMBOL QTY. INDOOR MANF. MODEL LOCATION CAPACITY CAPACITY CLG. HTG. REFER SCHEDULES UNIT VOLTS/ MCA MOCP TYPE ' WEIGHT NOTES N (TONS) (MBH) (SEER) (HSPF) PHASE (AMPS) (AMPS) (LBS.) 6 HP-1 1 FCU-1 CARRIER 25HCE448AO05 ROOF 4.0 45.6 14.0 8.2 208/3 14.5 25 R410A 197 1 c HP-2 1 FCU-2 CARRIER 25HCE448AO05 ROOF 4.0 45.6 14 8.2 208/3 14.5 25 R410A 197 1 0 HP-3 1 FCU-3 CARRIER 25HCE448AO05 ROOF 4.0 45.6 14 8.2 208/3 14.5 25 R410A 197 1 mool > HP-4 1 FCU-4 CARRIER 25HCE448AO05 ROOF 4.0 45.6 14 8.2 208/3 14.5 25 R410A 197 1 m NOTES: PERMIT o DRAWING HVAC/R • CONTROLS CONTRACTORS • ENGINEERS SERVICE • MAINTENANCE (503) 234-0477 • hunterdavisson.com PR �4 I N Lu o� � REGO cv 13 .2 C2 q�YNN WE�� k- 1 EXPIRES: 06/30/2020 ADJACENT OFFICE TENANT 2260 SF I I CONNECT NEW FAN COILS B TO EXISTING DUCTWORK I� AND REFRIGERANT PIPING (TYP 4) i I ADA I I I Z ESTROOM t-- _ ...__- _ .- - ---i--- - -- -T-- ® T SEE STRUCTURAL/ i SIESMIC CALCULATION I f I J PACKAGE FOR UNIT I , MOUNTING DETAILS. Elli Z OFFICE is OFFICE WORK ECH . /ELEC. D 6 ROOM V BAR I a Q ----- ------ - - -- ------ --- -- --- - -- 0 Q - Da Cy LV OFFICE I CIRC. FC-4 Fm W W T � FC-3 I I ` OFFICE 7080 SW FIR LOOP 5I TIGARD, OR FRONT OFFICE CONFERENCE OFFICE OFFICE I 3 4 I I REVISIONS c N E BUILDING ENTRY 77 3 = 0 _-_------1--- --------1--- - ------_1- _J--- ® LEGEND: o I I I DATE 12/18/2019 CLL Q DEMO © ® © DRAWN BY STC 0 c0 CAP CHECKED BY TW Q RELOCATE 0 LEVEL ONE 0 O" NEW FLOOR PLAN 0 CONNECT TO = EXISTING V L ONE FLOOR PLAN iN M 101 (D , •> LE E PERMIT 0 DRAWING WAR 60106104 HVAC/R • CONTROLS CONTRACTORS • ENGINEERS SERVICE • MAINTENANCE (503) 234-0477 • hunterdavisson.com PR ` � 1 N LU ' r I� EGON �q<YMV MiF-\• i DN — © EXPIRES: 06/30/2020 OFFICE DFFICE OFFICE OFFICE 4 15 16 17 ' II III RTU—t T OP N OFFICE OFFI CE OFFICE -2 I 0 13 I I I S T Tu-2 I Z _ - _ - ---- -------- -- ----� ---------- Z OFFICE I I I BREAK I J LU 12 I I I ROO = Z m W LU OFFICE 1 OFFICE IT COPIY ( p V O�FICE 19 RM I I (ym a Q Q — J CIRC. I OFFICE ST R I FmLu W 10 RTU-3 T O I i 7080 SW FIR LOOP OPEC I TIGARD, OR OFFI —4 OFFICE OFFICE OFFICE CONE. .O D" 9 8 7 RM . I I REVISIONS -- --a_____-- E ~3 0 3 0 U J _-_-_- _-_-I_-_-_---_-- ® LEGEND: o I I I I ( DATE 12/18/2019 L Q DEMO © ® © DRAWN BY STC 0 �; Qc CAP CHECKED BY TW ° Q RELOCATE LEVEL TWO 0 0" NEW FLOOR PLAN 0 N CONNECT TO EXISTING cLEVEL TWO FLOOR PLAN M102 0 cu y PERMIT 0 DRAWING HVAC/R • CONTROLS CONTRACTORS • ENGINEERS SERVICE • MAINTENANCE (503) 234-0477 • hunterdavisson.com �c0 PRr,7 H Lu 7► �E y �N7REGO oti r CD EXPIRES: 06/30/2020 ij CONNECT TO EXISTING \ SUPPLY AND RETURN DUCTWORK IN ATTIC (TYP 4) RTU-1 RTU-2 mmi J W HP 1 El El GED Fm HP-3 ❑ ❑ HP11 W Lu W O W • RTU-3 RTU-4 • � � Q Q - J a _ U LSI SEE STRUCTURAL/ W SIESMIC CALCULATION j PACKAGE FOR UNIT i MOUNTING DETAILS. 7080 SW FIR LOOP —� TIGARD, OR I I I REVISIONS c 0 E m n. Z. 0 0 L V .3 c 0 U LEGEND: o DATE 12/18/2019 QX DEMO L DRAWN BY STC 0 Qc CAP CHECKED BY TW 0 0 0 RELOCATE 0 ROOF PLAN C Q NEW I 0 o CONNECT TO c EXISTING 0 M103 �> ROOF PLAN PERMIT o DRAWING HVAC/R • CONTROLS CONTRACTORS • ENGINEERS SERVICE • MAINTENANCE (503) 234-0477 • hunterdavisson.com QED PR La PE, EGON ADJACEWI I 13 , Z° 5 OFFICE TENANT U__ E /2020 EXPIRES: 06/30 -- -- ----�------- (------- Em ------ -�-- ----, ' - - - 1 2261 1 , ® — Z B I I I DEMO EXIST FAN COIL r______i I r__-- AND THERMOSTATS. 1 1 I 1 I REUSE DUCT AND 1 L I L______J I REFRIGERANT PIPING. (TYP 4) I DEMO EXIST RTUS ADA I I I r---i r-----� / (TYP 4) ESTROOM I ' - _--. ----_-_- ---------- - ........... -- _. --7--- ® L L-----J DEMO EXIST HEAT PUMPS Q L_J L_J I 1 I I OFFICE OFFICE WORK F W ECH . /ELEC. 1 0 6 ROOM m Z ___J I___J W uu BARL=Lt V ---- ------ - 1 -- ------ ---- f -- ©1OFFICECIRC.2 ('-----, ------ I E LLIL------J - ----J I W i FRO T i -� 7080 SW FIR LOOP OFFICE CONFERENCE OFFICE OFFICE j I 1 TIGARD, OR 3 4 I1 I u I � 1 REVISIONS BUILDING o ENTRY 77 E I ' a .. I L_ 3 0 w U 7 o DATE 12/18/2019 0 DRAWN BY STC 0 0 CHECKED BY TW `0 LEGEND: LEVEL ONE FLOOR PLAN - DEMO ROOF PLAN - DEMO DEMO PLANS o Q DEMO t/8• _ 11_0. t/(D e• _ �'-o• N Oc CAP in 0 RELOCATEin MD101 o Q NEW CONNECT TO PERMIT = EXISTING o DRAWING