Plans (9) FPS2021 -00023
RECEo
FEB 18 1011
--- - BUILDING DIVISION
DECK DECK -
• •
O x 0 O O
o a
x
O O x
x '
— -- - - — 7Zf747- A 7z -
t ® x
® o
Lr
O .D.
/ D. .D. O . .
G ® 1
_ o FIE m,
-V1 OF! V M �i 7 0 "YA/O - sul
® I� OFFICE COPY
--
E.
® ® x
I -
x
' ' I
/-AH ® ® ® ® S-
I V
® ® ® 011 1 V m I OF OF
® � ' OFOF
OF Z I I V I I V O OR
oil L
OF ILO 0
-o ® �
OF ® 0 OF •
OF *1
OEZ0
Ir *F1 L ® OF OF I& OE
' i I
OF OF
DECK I {� ® ® I OF ®E DECK
OF
FE
HATCHED AREA IS OUTSIDE
OF CONTRACT.
A=ADD
R=RECUT/RELOCATE
E=EXISTING
P=PLUG
NOTES:
1. ADD AND RELOCATE HEADS AS NEEDED FOR TENANT IMPROVEMENT.
2. VIKING TO START AT EXISTING BRANCH UNES.
3. ALL NEW PIPING TO BE BLACK SCHEDULE 40 WITH SCREWED TYPE
C.I. FITTINGS OR GROOVE TYPE FITTINGS.
4. EXISTING PIPING, HEADS, AND HANGERS TO REMAIN UNLESS
OTHERWISE NOTED.
5. ALL HARING, PAINT PREP, OR PAINTING TO BE DONE BY OTHERS.
6. MKING'S SCOPE DOES NOT INCLUDE ANY RESPONSIBILITY, EITHER
WRITTEN OR IMPLIED, FOR THE CONDITION OR CURRENT CODE
COMPUANCE OF ANY EXISTING SPRINKLER SYSTEM EXCEPT AS MODIFIED
BY VIKING.
THIS DRAWING IS THE PROPERTY OF VIKING AUTOMATIC SPRINKLER COMPANY.
IT IS SUBMITTED IN CONFIDENCE AND IS NOT TO BE DISCLOSED OR UTILIZED
WrrHOUT THE WRITTEN PERMISSION OF VIKING AUTOMATIC SPRINKLER CO.
REVISIONS ABBREVIATIONS GENERAL NOTES WATER FLOW INFO SPRINKLER SYMBOL DESCRIPTION WET STAMP PROJECT:
, INTEGRATED HEALTHCARE
MARK BY DATE DESCRIPTION AFF- CENTERLINE ABOVE FINISH FLOOR 1.ALL MATERIAL AND EQUIPMENT TO BE NEW AND UNDERWRITERS STATIC: SYM STYLE MFG ESPONS THD "K' TEMP SIN# FINISH ESCUTCH. WRENCH QTY
ATB -CENTERLINE ABOVE TOP O JOIST APPROVED. RESIDUAL: SOLUTIONS LLC
BOB-CENTERLINE BELOW BOTTOM OF BEAM SEATTLE BOISE
BOD-CENTERLINE BELOW BOTTOM OF DECK 2.PIPING DIMENSIONS ARE CENTER TO CENTER EXCEPT RISER& FLOWING: CONC PEND VIKING QUICK 1/2' 5.6 155° VK462 STD WHITE 23143 6 PORTLAND FIRE PROTECnON POCATELLO
BOP-CENTERLINE BELOW BOTTOM OF PURLIN DIMENSIONS SHOWN THUSLY(1-6)WHICH ARE END TO END. 10200 SW GREENBURG RD.
BOJ- CENTERLINE BELOW BOTTOM OF JOIST D 20 PSI: LONGVIEW MEDFORD
3. PIPING,HANGERS,AND EARTHQUAKE BRACING SHALL BE IN DATE: VIKING AUTOMATIC SPRINKLER COMPANY TIGARD, OR 97223
BTJ -CENTERLINE BELOW TOP OF JOIST
Qg CENTERLINE OF PIPE,COLUMN,OR BEAM ACCORDANCE WITH NFPA PAMPHLET NO.13,APPLICABLE EDITION. LOCATION: 3245 NW FRONT AVENUE
CUT ON JOB 4.JOINING OF PIPE AND FITTINGS,THREADED AND WELDED SHALL
FO - FIELD ORDER BE IN ACCORDANCE WITH NFPA PAMPHLET NO.13. INFO FROM: PORTLAND, OREGON 97210 . 24 hrs. (503) 227-1171
CPLG-COUPLING 5.OWNER TO MAINTAIN 40°F MINIMUM IN LOCALITIES SUBJECT TO PUMP GPM: PUMP PSI. TYPE: OREGON CCB#64837 METRO LIC#2816•WASHINGTON LIC#VI-KI-NA-S373NT ROAD SCHOLAR TI - SUITE 700
FLEX-FLEXIBLE COUPLING FREEZING PROTECTED BY A WET PIPE SPRINKLER SYSTEM AND IN
GOE-GROOVE ONE END ENCLOSURES FOR DRY PIPE,DELUGE,OR ANY OTHER VALVES CONTRACT WITH:
GOL-GROOVED WELDED OUTLET APPROVING AGENCIES DWG RELEASE DATES:
GxG-GROOVE x GROOVE CONTROLLING WATER SUPPLIES. ® CONC PEND EXISTING QUICK 112' S.6 155°t-1- STD WHITE - - COORDINATION- Date Drawn: Drawn By: SHEET: 1 OF 1
GxP-GROOVE x PLAIN 6.STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORT THE CITY OF TIGARD P.E./PERMIT- 2/18/2021 BATEMAN .
ROL-THREADED WELDED OUTLET SPRINKLER PIPING IS THE RESPONSIBILITY OF THE OWNER FABRICATION-
TOTALSPRINKLERS SHOWN ON THIS SHEET 6 Scale: Job No.
TOE-THREAD ONE END AND/OR HIS STRUCTURAL REPRESENTATIVE. CONSTRUCTION-
TxG- THREAD x GROOVE TOTAL SPRINKLERS REQUIRED ON THIS CONTRACT 6 AS-BUILTS- 1/8" 11-01,
OPC-1006