Plans (5)
FPS2020-00102 co r- MM "\7 tG tC> I . ' 0� LINCOLN TOWER H zJohnson � � W= FIRE ALARM SYSTEM °Controls Mimi M CO Ro 0 0�0 o�� 0 oWM tY co DRAWING INDEX LEGENDS APPLICABLE CODES & STANDARDS JOHNSON CONTROLS CONTACTS QY� JURISDICTIONS WITHIN THE STATE MAY HAVE AMENDMENTS TO THE STATE ADOPTED CODE.CHECK Sales Representative Drawings Reviewed By K1774 THE LOCAL JURISDICTION AUTHORITY FOR MORE DETAILS. Oregon Structural Specialty Code,2019 Edition BRYAN ADAMS MARIA GERRONE BRYAN.ADAMS@JCI.COM MARIAGERRONE@JCI.COM Oregon Fire Code,2019 Edition PHONE:503-683-9000 PHONE:503-683-9000 NICET LEVEL IV #126987 Oregon Mechanical Specialty Code,2019 Edition SchedU/Ing Sheet List Table Oregon Electrical Specialty Code,2017 Edition MIRANDA CASTLE MIRANDA.CASTLE@JCI.COM Sheet Number Sheet Title Nations!Fire Alarm Code(NEPA 72),2016 Edition PHONE:503-683-9000 FA-001 COVER SHEET FIRE ALARM SYMBOL LEGEND FA-101 DEVICE PLACEMENT PLAN-9TH FLOOR FA-501 I PANEL DETAIL,CALCULATIONS AND WIRING DETAILS SYMBOL DESCRIPTION BRAND MODEL BACKBOX WIRE = TYPE PANELS (E) NAC9 4009 IDNET NAC EXTENDER PANEL,120 VAC,BEIGE SIMPLEX 4009-9201 SIMPLEX CABINET NIA INITIATING DEVICES (E) ADDRESSABLE PHOTOELECTRIC SMOKE SENSOR W/STANDARD SIMPLEX 4098 9714 HEAD4"OCT,1-1/2'D M OCBUSA ESS GROUPCY ): SPRINKLER S FUPROTECTION: Y SP NKLERED V BASE 4098-9792 BASE NOTIFICATION APPLIANCES # CONVENTIONAL MULTI-CANDELA STROBE,WALL MOUNT,RED,CLEAR SIMPLEX 4906-9101 SINGLE GANG 1-112"D V LENS,FIRE #K END-OF-LINE RESISTOR 3.3K EOL 4081-9002 SCOPE OF WORK PROJECT DIRECTORY END-OF-LINE RESISTOR 4.7K EOL SIMPLEX 4081-9003 END-OF-LINE RESISTOR 6.8K EOL 4081-9004 MODIFY EXISTING FIRE ALARM SYSTEM: PROVIDE NEW DEVICES AS SHOWN ON DRAWINGS. Site Johnson Controls District-448 END-OF-LINE RESISTOR 10K EOL 4081-9008 ALL NEW WIRING TO BE CLASS B. LINCOLN TOWER 10250 SW GREENBURG RD 6305 SW ROSEWOOD ST,SUITE A THE EXISTING FIRE ALARM SYSTEM SHALL NOT BE DISCONNECTED OR TAKEN OUT OF SERVICE WITHOUT WRITTEN PERMISSION FROM THE OWNER. IT TIGARD,OR 97223 LAKE OSWEGO,OR 97035 PHONE: 503-683-9000 IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH THE OWNER THE TIMING OF ANY EXISTING FIRE ALARM SYSTEM DEMOLITION WORK FAX: 503-675.6521 SERVICE:503-683-9001 Owner Installer DESIGN STATEMENT SHORENSTEINGRE REALTY SERVICES CAPITOL ELECTRIC 10220 SW GREENBURG RD 11401 NE MARX ST TIGARD,OR 97223 PORTLAND,OR 97220 DESIGN IS FOR FIRE ALARM NOTIFICATION OF THE LINCOLN TOWER 9TH FLOOR GUILD MORTGAGE OUTLINED AREA OF WORK PLEASE PROVIDE COMPLETED IVFPA 72 RECORD OF ZE COMPLETION A C) FINAL INSPECTIO"1 C) N LO t0 19 ABBREVIATIONS LEGEND DEVICE TAG LEGEND is AC = ABOVE CEILING NEC=NATIONAL ELECTRIC CODE AFF= ABOVE FINISHED FLOOR NFPA=NATIONAL FIRE PROTECTION ASSOCIATION --PANEL DESIGNATOR AHJ= AUTHORITY HAVING JURISDICTION NIC=NOT IN CONTRACT . FA=FACP(NON-NETWORK) o ALM=ALARM NPU=NETWORK PROCESSING UNIT CD ANN= ANNUNCIATOR NTS=NOT TO SCALE • #:=NODE NUMBER BMS=BUILDING MANAGEMENT SYSTEM PAP=PRE-ACTION PANEL • T#:=TRANSPONDER NUMBER C= CEILING MOUNTED RC=EXISTING TO REMOVE AND COVER • #:T#=.NODE:TRANSPONDER NUMBER CD=CANDELA RATING RD=EXISTING DEVICE TO BE RELOCATED • N#:=NAC EXTENDER NUMBER c DET = DETECTOR RL=RELOCATED DEVICE CIRCUIT DESIGNATOR DGP=DATA GATHERING PANEL RR=REMOVE EXISTING&REPLACE WITH NEW • • A#=IDNAC CIRCUIT NUMBER E=EXISTING TO REMAIN SCC = STATUS COMMAND CENTER D#=DOOR HOLDER CIRCUIT NUMBER EOL=END OF LINE SLC=SIGNALING LINE CIRCUIT ACCEPTABLEEPO =EMERGENCY POWER OFF SMK= SMOKE • F#=FIRE PHONE CIRCUIT CABLE TYPESER=ELEVATOR RECALL SUPV=SUPERVISORY H#=AUDIBLE{HORN)CIRCUIT NUMBER LU FAA =FIRE ALARM ANNUNCIATOR TAC=TRUEALERT ADDRESSABLE CONTROLLER • M#=IDNET LOOP NUMBER FIRE ALARM WIRE LEGEND FACP=FIRE ALARM CONTROL PANEL TOS=TOP OF SHAFT • P#=POWER CIRCUIT NUMBER C o FATC =FIRE ALARM TERMINAL CABINET TRBL=TROUBLE • S#=SPEAKER CIRCUIT NUMBER OFFICE COPY UJ 1W a z z a FBO=FURNISHED BY OTHERS 7S=TAMPER SWITCH • V#=VISUAL CIRCUIT NUMBER CIRCUIT DESCRIPTION CONSTRUCTION GAUGE CIRCUIT PROPERTIES a a = W = _ FCC=FIRE COMMAND CENTER TYP=TYPICAL • Z#=ZONE NUMBER U. " ~ ~ o FSD = FIRE SMOKE DAMPER LION=UNLESS OTHERWISE NOTED DEVICE NUMBER 0 7"S UAL 2 COND.SOLID 14 AWG X X FTR=FIRE ALARM TRANSPONDER VCC=VOICE COMMAND CENTERoBRANCH/ISOLATED LOOP DESIGNATOR: 16 H=HIGH HUMIDITY VT= VALVE TAMPER °' (L#)=IDNET ISOLATED LOOP NUMBER Q/ CONDUIT SIZE MAX CONDUCTOR AREA CONDUIT SIZE MAX CONDUCTOR AREA HT=HEIGHT W=WATTAGE . # =IDNAC BRANCH NUMBER m 6 112• 0.122 SQ.INCH* 1-1/4" 0.598 SQ INCH* HVAC =HEATING VENTILATION&AIR CONDITIONING W/= WITH { )- M 314• 0.213 SQ INCH* 1-112" 0.814 SQ INCH* IMS=INFORMATION MANAGEMENT SYSTEM W/O= WITHOUT • (E#:#)=EPR2 NUMBER:BRANCH NUMBER Z N a MAX =MAXIMUM WF=WATERFLOW 1.IDNAC=ADDRESSABLE NOTIFICATION CIRCUIT W W N y 1• 0.346 SQ INCH* 2• 1.342 SQ INCH* o 11.1 MIN=MINIMUM WG=WIRE GUARD 1:T2:A2-1(E1:1) 2.EPR=ENHANCED POWER REPEATERCD c *40%CONDUIT FILL PER N.E.C. STP=SHIELDED TWISTED PAIR WA=NOT APPLICABLE WP=WEATHERPROOF J ci ITEMS SUCH AS CAPACITANCE BETWEEN CONDUCTORS AND WIRE GAUGE CAN BE CRUCIAL TO THE CIRCUIT DESIGN OF THIS SYSTEM INSTALLATION. NAC=NOTIFICATION APPLIANCE CIRCUIT XP=EXPLOSION PROOF C.7 o THE INSTALLING CONTRACTOR IS RESPONSIBLE FOR SELECTING AND INSTALLING CABLE MANUFACTURER AND MODEL THAT MEETS OR EXCEEDS NDU=NETWORK DISPLAY UNIT 00 0 r THE ABOVE REQUIREMENTS.RECOMMENDED CABLE MANUFACTURERS AND MODEL NUMBERS ARE AVAILABLE UPON REQUEST. ..1 Cn in ca SYSTEM SEQUENCE OF OPERATIONS - C, o W E VIAL-11"11 1 >I Or FERMI U Ltd Q y THE ISSUANCE OF A PERMIT OFFICE COPY Z 0 J C.� _ _ BASED ON CONSTRUCT ION --� DOCUMENTS AND OTHER CT'Y OF'TTGARTX DATA SHALL NOT PREVENTD FOR CODE COMPLLANCE a THE CODE OFFICIAL FROM APPmY� N w REQUIRING THE CORRECTION OF ERRORS.OSSC 105.4 4TG j PC A dr ss: I .� C S ie : 0 Z $ . Dane: �/ p :.... of Z F Z o a o 0 ~ GENERAL NOTES RISER DIAGRAM 6 ,. J co 0 Q Z N CO p- U Q J a U Z ¢ z 0 Of 1. THESE DRAWINGS DEPICT GENERAL LOCATIONS OF LIFE SAFETY EQUIPMENT&FIELD DEVICES.EXACT ROUTING OF CONDUITS 1S TO BE z z > 14 � w J DETERMINED IN THE FIEF BY THE INSTALLING CONTRACTOR TO SUIT CONDITIONS. ALL CHANGES SHALL BE CLEARLY INDICATED ON RISER NOTES: } z ¢ Z zo z w o a O THE RECORD DRAWINGS. w z ¢ 0 c� < ¢ co J it ¢ CD z O O v, < ¢ < a, z o J d t- 0° 2. SHOULD ANY CONDITIONS EXIST THAT DIFFER FROM WHAT IS INDICATED ON THESE DRAWINGS WHICH CAUSE MAJOR DEVIATIONS IN 1. RISER IS A DIAGRAMMATICAL REPRESENTATION OF THE SYSTEM to Cn co W ¢ `� o ¢ 0 C1 �. cn > J W U (> CO� O J O V O W Ul W THE WORK SHOWN,THE CONTRACTOR SHALL CONTACT JOHNSON CONTROLS IN A TIMELY MANNER SO AS NOT TO IMPAIR THE ARCHITECTURE IN BUILDING CROSS SECTION.IT IS NOT INTENDED TO ,� Co > a ¢ ~ r z w } } (n CONSTRUCTION SCHEDULE. RE=PRESENT ACTUAL WIRE RUNS,PANEL CONFIGURATIONS OR < CL _ 0 o LU W w W COi Z o co oo LL o J = a w U �- 3. CONTRACTOR IS RESPONSIBLE FOR MAKING AND OBTAINING APPROVAL FOR ALL NECESSARY ADJUSTMENTS IN CIRCUITING AS PENETRATIONS.REFER TO FLOOR PLANS AND PANEL DETAILS FOR z z T, z ~ ° m UJ o crop c" __J o `- "� c" z > z g REQUIRED TO ACCOMMODATE THE RELOCATION OF EQUIPMENT AND/OR DEVICES WHICH ARE AFFECTED BY ANY AUTHORIZED CHANGE. CIRCUIT ROUTING AND CONFIGURATION INFORMATION. o M o- M o � o = c„ w W- W m 1 o z w o ¢ 3 0 S m_ M as M m aw ¢ > z a a p � ¢ J O t- z z o H n a. ALL CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. 2. ALL WIRING SHALL COMPLY WITH APPLICABLE ELECTRICAL CODES. Q '� a ° -� J C w W LL ¢ = o c" 0) 0 � o � O � a J J = ¢ U) r U J d' W = d) ¢ o W 25 Cr. 4. A STAMPED SET OF APPROVED FIRE ALARM DRAWINGS SHALL BE AT THE JOB SITE AND SHALL BE USED FOR INSTALLATION. REFER TO'APPLICABLE CODES&STANDARDS'ON SHEET FA-001 FOR �' o `[ �' ¢ ¢ ¢ `C 0 1 c '�' o ►- Cr W '" > Of tt- ►W- IW- tW- F FW MW- d } M M Y w O ¢ Q p W n Cr W w 5. THE POWER CIRCUIT TO THE FACP AND TO THE FIRE ALARM POWER SUPPLIES SHALL BE ON A DEDICATED 120V,20A BRANCH CIRCUIT S, ECIFIC CODE REFERENCES. ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ W U) cn cn 0 CO � � ¢ ¢ ¢ = w � i- n BREAKER,AND SHALL HAVE A RED MARKING,LOCK-ON PROVISION AND SHALL BE IDENTIFIED AS"FIRE ALARM CIRCUIT CONTROL.' THE 3. DEVICES ARE TYPICAL.SEE FLOOR PLAN FOR QUANTITY&LOCATIONS. � � � � � � r= � � � a z z z o _J z � w w � CO � � � V U fJ U U U U U Q Z Z W d J J J W ¢ ¢ W Y LOCATION OF THE CIRCUIT DISCONNECT MEANS(CIRCUIT BREAKER)SHALL BE PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢ o i-- F- F- ¢ w w o a cr U UNIT. CTRL UNIT ANNUNCIATION NOTIFICATION FIRE SAFETY CONTROL 6. UPDATE THE AS-BUILT DRAWING SET DAILY WITH JOB PROGRESS. RETURN THE AS-BUILT DRAWING SET TO JOHNSON CONTROLS NO SYSTEM INPUTS A B C D E F G H I J K L M N 0 P Q R S T U V w X Y LATER THAN 7 DAYS AFTER FINAL TEST. 1 SMOKE SENSORIDETECTOR X X X X X X X X X1 X X X X 7. THE CONTRACTOR WILL MAINTAIN ALL AREAS OF THE BUILDING IN A NEAT AND WORKMANLIKE MANNER. ¢ 8. DO NOT APPLY POWER EXCEPT IN THE PRESENCE OF A FACTORY TRAINED JOHNSON CONTROLS TECHNICAL REPRESENTATIVE. 2 MANUAL PULL STATION X X X X X X X X w 9. ANY SMOKE DETECTOR HEAD INSTALLED BEFORE THE BUILDING IS CLEANED AND ACCEPTED SHALL BE COVERED TO PROTECT FROM 3 DUCT SENSORIDETECTOR-SUPERVISORY X X X X X X X o DUST. ANY FALSE ALARMS DUE TO DIRT CONTAMINATED HEADS SHALL BE THE RESPONSIBILITY OF THE FIRE ALARM INSTALLER. 4 MAIN FLR.ELEV.LOBBY SMOKE DETECTOR X X X X X X XX X X X X X X X W he 10. THE FIRE ALARM INSTALLER WILL MAINTAIN THE FIRE RESISTANCE INTEGRITY OF ALL WALL,CEILING,AND ROOF ASSEMBLIES ANY TIME (N9.V1 N9:V3 V 5 ELEVATOR LOBBY SMOKE DETECTORS(EXC.MAIN FLR) X X X X X X X X X X X X X X X C-4 THAT WORK IS NOT ACTIVELY BEING PERFORMED. 10 ��n' 6 ELEVATOR MECH.ROOM HEAT DETECTOR X X X X X X X X X X co g 11. INSTALLATION OF DEVICES SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. POWER LIMITED AND NON-POWER LIMITED FIELD WIRING MUST BE INSTALLED WITHIN THE FACP ENCLOSURE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND (N9:V1K V 7 ELEVATOR MECH.ROOM SMOKE DETECTOR X X X X X X X X X X X X X X X APPLICABLE ELECTRICAL CODES.REFER TO'APPLICABLE CODES&STANDARDS`FOR SPECIFIC CODE REFERENCES. 10 N9:V2 8 ELEVATOR SHAFT HEAT DETECTOR X X X X X X X X X X 'tel' 12. ALL WIRING SHALL BE INSTALLED ACCORDING TO APPLICABLE ELECTRICAL CODES. (E) 9 ELEVATOR SHAFT SMOKE DETECTOR X X X X X X I X I X1 X X1 I X X X X1 X z R. Of13. FIRE ALARM CIRCUITS SHALL BE IDENTIFIED IN ACCORDANCE WITH APPLICABLE ELECTRICAL CODES. MARK ALL FIRE ALARM WIRES IN (N9;V1} (E) {E} (E) V 10 ELEVATOR POWER MONITOR X X X X X X DRAWN BY: HERMANT N9:V1 °- ACCORDANCE WITH APPLICABLE ELECTRICAL CODE SECTIONS FOR POWER LIMITED AND NON-POWER LIMITED WIRE. 10K� 11 WATERFLOW SWITCH X X X X X X X X X X X CHECKED BY: M.GERRONE g14 FIRE ALARM CABLE INSTALLED IN DUCTS,PLENUM,AND OTHER SPACES USED FOR ENVIRONMENTAL AIR SHALL BE TYPE FPLP. 12 TAMPER SWITCH X X X X X X ISSUE DATE: 9/15/20 15. FIRE ALARM CABLE INSTALLED IN THE VERTICAL RUNS AND PENETRATING MORE THAN ONE FLOOR OR CABLES INSTALLED IN VERTICAL L ---.1 13 POST INDICATOR VALVE SWITCH X X X X X X JOB#: RUNS IN SHAFTS SHALL BE TYPE FPLR. (E) 4009 14 FIRE PUMP RUNNING X X X X I X I XI PROJECT# 448:619576201 16. FIRE ALARM CABLE INSTALLED IN UNDERGROUND CONDUIT OR OTHER WET LOCATIONS SHALL BE UL LISTED FOR WET LOCATIONS. 15 FIRE PUMP POWER FROM ALTERNATE SOURCE X X X X X X JOHNSON CONTROLS 0 2020 17. FIRE ALARM CIRCUITS EXTENDING BEYOND ONE BUILDING AND RUN OUTDOORS SHALL BE INSTALLED IN ACCORDANCE APPLICABLE NAC9 ELECTRICAL CODES,WHERE APPLICABLE. 16 FIRE PUMP PHASE LOSSIREVERSAL X X X X X X SYSTEM: 18. ALL WIRING,INCLUDING SHIELDS MUST BE DRY AND FREE OF SHORTS AND GROUNDS. 17 GENERATOR RUNNING X X X X X X FIRE ALARM SYSTEM 19. ALL SHIELDED WIRE MUST HAVE SHIELD CONTINUITY AT FULL LENGTH OF THE WIRE. 120 VOLT AC 18 GENERATOR FAULT X X X X IX X 20. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. 9TH FLOOR 19 FIRE ALARM AC POWER FAILURE X X X X X OFFICE COPY SHEET: 21. 120VAG IS NOT PERMITTED IN THE SAME CONDUIT WITH LOW VOLTAGE WIRING. 20 FIRE ALARM SYSTEM LOW BATTERY X X X X X 22. MAINTAIN MAXIMUM CONDUIT FILL RATIO AS PER APPLICABLE ELECTRICAL CODES REQUIREMENTS. 21 OPEN CIRCUIT OR GROUND FAULT X X X X X 23. EXISTING CONDUITS MAY BE USED BY THE INSTALLATION CONTRACTOR AS DEEMED NECESSARY;HOWEVER,ANY EXISTING CONDUIT WILL BE USED ONLY IF CONDUITS MEET CURRENT STANDARDS AND CODES.JOHNSON CONTROLS MAKES NO STATEMENTS WRITTEN OR 22 CLASS B NOTIFICATION CIRCUIT(NAC)-SHORT IX X1 I X X X COVER SHEET VERBAL AS TO THE CONDITION OF EXISTING CONDUITS. N '.Lr-," (/� 2`0(n 1 IY 1 il£iJ L L-- v n z ¢ IMPORTANT NOTICE TO USER:This information may not be sold or transferred to any third party,used on other projects or additions to the project for which it was prepared,or used for completion of this project by any third party. Johnson Controls disclaims all liability for the use or reuse of altered files by the user or s FA-001 < any third party and such use will be a user's sole risk. User shall,to the fullest extent permitted by law,defend,indemnify,and hold Johnson Controls harmless y CD from any and all claims for loss,damage or injury arising directly or indirectly from any such unauthorized use. 0 Johnson Controls 2020.All rights reserved.Reuse,copying,modification or alteration of the drawings and other information contained herein is strictly prohibited. GENERAL NOTES: 1. ALL CEILINGS ARE ASSUMED TO BE 10'A.F.F.,SMOOTH CONSTRUCTION UNLESS _ NOTED OTHERWISE. 2. DEVICES NOT IN SCOPE ARE EXISTING TO REMAIN, o m� KEY NOTES: u J o� O VERIFY LOCATION AND MODEL NUMBER OF THE EXISTING NAC PANEL. VERIFY a n LL HOW EXISTING NAC PANEL IS TRIGGERED AND MARK ON AS-BUILT REDLINES. IF O TRIGGER3ED BY IDNET VERIFY ADDRESS. ,I/1w mv, OVERIFY IF THERE IS AN EXISTING SMOKE ABOVE THE NAC PANEL. VERIFY IDNET C O o�g ADDRESS AND MARK ON AS-BUILT REDLINES. o W' L wom u m owl Q O Wm � W U MOO � N M<W' AREA OF WORK AREA OF WORK CONFERENCE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE 907 15 908 909 910 911 912 913 914 915 916 917 918 919 920 921 N9:V3-4 \ V V 75 N9:V3-5 / 75 11 110 HALL N9:V3-3V ' N9:V3 2 N9:V2-9 948 �'' > N9:V2) V 10 / OPEN OFFICE V 906 ^5 N9:V2-8 SERVER43 CONF�OFFICE V OPEN OFFICE CONFERENCE ZD LL s N m N9:V2-7 Y 75 30 N9:V2-6 R V 0 ♦ WORK RECEPTION \ F 945 i saa NOT IN SCOPE WORK 3 o — - 940 V ,� J ' - f 49V2-5 V2-5 NOT 1111 OPEN OFFICE SCOPE -- - NOT IN — -- -- - Ns:vz-z 15 OPEN OFFICE ♦♦Wnn v Ii 905 -- - r SCOPE I - HALL V -- V 923 i v NOT IN £ r 939 Uj 0 Q BREAK �/ ' NOT IN — -- SCOPE V 15 Ns 1 - V2 . w --- - - - - v 0 946 E r E - - 30 T- NAC9EZ� I O -' EC TI V 1 BREAK V m CO) w ow_j \ 90 :' N9:V3.1 STORAGE S � WN • V1) _ -.-... 938 - Z O No 15 LJJ NK CON OFFICE L J 935 937 N9 V2-3_N9:V3-6 0 9:V1CD ti 15 --- N OFFICE 0 NOT IN a AK 924 U J N D SCOPE NOT IN 90 TO NAC9 V y ♦ ♦ pPlc SCOPEy Z ♦♦��� z o " V o V (N905 9 70VA� 9:V1J V (E) 934 WORK OPEN OFFICE 947 _ -z.> 03 N9:V1-2 75 OFFICE E Ng V3-9 OPEN OFFICE N9:V24 75 933 925 LL CO N9:V3-7 O6 -- AL -- V -- 3 g 15 3 9:V 0 N ♦ V N . 1-3 0 N V 15 NOT IN OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE N9:V3-8 903 902 901 j SCOPE 932 931 930 929 928 927 926 CONFERENCE :V1 = 904 CO ER CE FFI FF E 0 IC 9 8 9 91 m 0 a — a o r= a U y W O Y 2 V Q U W g r a a 0 J N W Y to Q o N � 0 N m W z DRAWN BY: R.HERMANT a CHECKED BY: M.GERRONE 5 ISSUE DATE: 9/15/20 JOB#: PROJECT#: 448:619576201 JOHNSON CONTROLS©2020 SYSTEM: FIRE ALARM SYSTEM SHEET: DEVICE PLACEMENT PLAN - 9TH FLOOR N t DEVICE PLACEMENT PLAN - 9TH FLOOR- SCALE:118" = V-0" FA-1 01 SCALE:118"=V-0" IN FEET x m 0 4' 8' 16' ©Johnson Controls 2020.All rights reserved.Reuse,copying,modification or alteration of the drawings and other information contained herein is strictly prohibited. GENERAL NOTES: 1. EXISTING DEVICES SHOWN SHADED FOR REFERENCE. _ m� KEYNOTES: 1O VERIFY LOCATION AND MODEL NUMBER OF THE EXISTING NAC PANEL. VERIFY HOW EXISTING NAC PANEL IS TRIGGERED AND MARK ON AS-BUILT REDLINES. IF u TRIGGER3ED BY IDNET VERIFY ADDRESS. ^ O o aaLL O ` w N N O Omo Orn m wOT O V � owe DEVICE MOUNTING HEIGHT REFERENCE END OF LINE RESISTOR CODES TrueAlert CONVENTIONAL APPLIANCES �0w U SOU PER NFPA 72 SIMPLEX 4906 SERIES WALL MOUNTED VISUAL w VISUAL APPLIANCE MOUNTING HEIGHT CONSIDERATIONS IN SLEEPING ROOMS 1. MIN DISTANCE IN SLEEPING ROOMS IS 24"(610mm)FROM CEILING TO TOP A/C SUPPLY NOTE:REFER TO PANELJMODULE AND DEVICE STANDARD ELECTRICAL OF LENS FOR 1 10C STROBES WITHIN 16'OF THE PILLOW OR RETURN INSTALLATION INSTRUCTIONS FOR PROPER BOX MOUNTING 4"SQUARE THE 4"REQUIREMENT FOR SMOKE DETECTORS HAS TERMINATIONS. BOX, 1-112"DEEP 2. 177CD STROBES, USED IN SLEEPING ROOMS,CAN BE WITHIN THE 24" DIFFUSER BEEN REMOVED FROM THE 2010 EDITION OF NFPA 72 ELECTRICAL BOX t� (610mm)MINIMUM DISTANCE FROM THE CEILING.THE HIGHER INTENSITY IS REF. BAND NUMBER o SURFACE MOUNT TO COMPENSATE FOR A POSSIBLE SMOKE LAYER. MODEL !Z WATTS CIRCUIT TYPE FIRE ALARM PANEL/MODULE ADAPTER SKIRT 15/8" ) I �- 3'MINIMUM 4" NOTE:MEASUREMENTS NUMBER 3 2 3 4 5 MINIMUM (102mm) SHOWN ARE TO THE CLOSEST 4081-9001 733-892 2.2K RED RED RED GLD N/A 1/2 ANNUNCIATOR(4300) 4004,4010(TROUBLE) o � (41mm)DEEP.CONDUIT CEILING v, EDGE OF THE DETECTOR. N.O. INITIATING PULL,SMOKE, 4004',4004R,4005',4006,4100, CUTOUTS ARE PROVIDED -� 4081-9002 733-893 3.3K ORG ORG RED GLD N/A 1 HEAT,WATERFLOW,TAMPER,ETC. 4120,4100U,ZAMs �� ON ALL FOUR SIDES, FOR CEILING HEIGHTS LESS THAN 86" NFPA 72 AUDIBLE APPLIANCE 6"MIN NAWCEILING MOUNTE 4" 24 PT.1/0 SWITCH SUPV. 4605-7401,4100 SERIES o� SURFACE MOUNTING (2180mm),THE VISUAL LENS MOUNTING HEIGHT (152.4mm MIN)BELOW FINISHED CEILING SMOKE/HEAT (102mm CURRENT LIMITED N.O. INIT., 4090 IDNET IAM(EOLR) DETECTOR ) 4061-9003 733 896 4.7K YEL VT RED GLD N/A 1/2 NOTIFICATION(DACT) 2080-9024 ® o SHALL BE WITHIN 6"(150mm)OF THE CEILING. J_ 4004,4005,4090-9001 IDNET IAM, N/0 INITIATING PULL,SMOKE, 0 ACCEPTED HERE 12"(305mm) 4081-9004 733 886 6.8K BLU GRY RED GLD N/A 112 214-20M 3 AM(TROUBLE)II 2 PT IIO CANDELA INTENSITY + + HEAT,W.FLOW,TAMPER,ETC Q HEAT DETECTORS MAXIMUM TO TOP OF SENSOR 4-20MA ZAM(TROUBLE) CURRENT LIMITED N.O. INITIATING PLJG ACCESSIBLE AUDIBLE ONLY NEVER HERE 4081-9005 733-984 1.8K BRN GRY RED GLD N/A 1/2 4090-9001 IDNET IAM FROM REAR OF AUDIBLE/VISUAL ; I (INLINE) &VISUAL ONLY TO EXIT DOOR 4005',4090-9001 IDNET IAM HOUSING 5' ALL MOUNTED 4081-9006 733 890 560 GRN BLU BRN GLD NIA 1 N.C.INITIATING(EOLR) TO NEXT APPLIANCES (MAX.)) SMOKE/HEAT DETECTOR 4100,41000 EVICE OR (1524mm) 4081-9007 733-891 1.2K BRN RED RED GLD NIA 1 N.C. INITIATING(EOLR) 4005 TOP OF LENS: NAC CIRCUI 4004,4005,4006,4008,4009,4010, 96" 2044mm A.F.F MAXIMUM (+) (+ OL SYNCHRONIZE MORE 4081-9008 733-894 10K BRN BLK ORG GLD N/A 1/2 NOTIFICATION �� ( ) RESISTOR THAN TWO APPLIANCES I 1 1 4100,41000 FOR CEILINGS<86" 2180mm ( )A.F.F.: TERMINATION VIEW:REAR OF DEVICE IN ANY FIELD OF VIEW. MAGNETIC 5" 4081-9009 733-912 20 RED BLK BLK GLD N/A 1 TO MR-101 RELAY COIL 4005 8 POINT 110 <=6"(150mm)FROM CEILING CLASS B WIRING 96"MAX(ADA, IBC,NFPA) DOOR (127mm) N.C. INIT.(ACROSS CONTACTS) 4005`,4090-9001 IDNET IAM 90"MIN(2286mm MIN) BOTTOM OF LENS: (E FINIS MAX) HOLDER WIRING NOTES ABOVE FINISHED FLOOR i SIDE WALL 24 PT. (ACROSS CONTACTS 4605-7401,4100 SERIES 80"(2032mm)A.F.F.MINIMUM ABOVE FINISHED FLOOR 4081-9010 733-973 1K BRN BLK RED GLD N/A 1 TO TOP OF LENS (OTHER MOUNTING HEIGHTS SHALL BE FINISHED CURRENT LIMITED N.O.INIT. 1. MAINTAIN CORRECT POLARITY ON TERMINAL PERMITTED BY THE AHJ PROVIDING IT MEETS t7° DOOR WALL- (IN SERIES WITH CONTACT) 4090-9001 IDNET IAM MOUNTING OPTION „B„ CONNECTIONS. 80"MIN(ADA,IBC,NFPA) THE SOUND LEVEL OUTPUT REQUIRED.) WIDTH 4081-9011 733-974 100 BRN BLK BRN GLD NIA 1/2 ANNUNCIATOR(N2) 4006,4008,4010 2, ALWAYS CUT CONDUCTORS AND SECURE UNDER (2032mm MIN) FIRE MANUAL PULL �il LESS 3" TERMINALS.NEVER LOOP WIRES UNDER STATION ( )76mm 4081-9012 733-985 22K RED RED ORG GLD N/A 1/2 SPEAKER CIRCUIT 4003 TERMINALS. ABOVE FINISHED FLOOR PHONE 4081-9013 734-086 4.99K YEL WHT WHIT BRN BRN 112 3. ANY WIRE SPLICES TO BE MADE BY LISTED AND TO BOTTOM OF LENS JACK N.C. INITIATING(SECURITY AHJ APPROVED METHODS,4081-9014 734-092 2.4K RED YEL RED GLD NIA 1/2 4090-9001 IDNET IAM o MONITORING EOLR) NOTE:REFER TO THE PROPER DEVICE ® CURRENT LIMITED N.O.INIT. MOUNTING OPTIONS 48"MAX(ADA)(1219mm) ! j 4081-9015 734-093 1.5K BRN GRN RED GLD NIA 1/2 (SECURITY MONITORING EOLR) 4090-9001 IDNET IAM OPTION' DESCRIPTION NOTE INSTALLATION INSTRUCTIONS FOR BACKBOX MOUNTING HEIGHT. 48"MAX(NFPA,ADA)(1219mm MAX) i 4081-9016 734-149 150K BRN GRN YEL GLD N/A 1/2 42"MIN(NFPA)(1067mm MIN) 4081-9017 734-171 3.9K ORG WHT RED GLD NIA 1 A SINGLE GANG BOX, 1-112"(64mm)DEEP BY OTHERS.WHEN SURFACE FINISHED MEASUREMENTS SHOWN ARE 4081-9018 734-168 10K BRN BLK ORG GLD N/A 1 70VRMS CONSTANT SUPV. NAC 4100-1260 B 4"(102mm)SQUARE BOX, 1-1/2"(38mm)DEEP,MINIMUM MOUNTING USE 4905-9937(RED)OR TO TOP OF PULL HANDLE 378-090 8.2K GRY RED RED GLD N/A 1/2 SECURITY MONITORING(EOLR) 4100,41000 C 2 GANG BOX, 1-1/2"(38mm)DEEP 4906-9940(WHITE)SKIRT FLOOR 378-046 5.6K GRN BLU RED GLD NIA 1/2 N.O.SECURITY MON.(SERIES) 4100,41000 D SIMPLEX 2975-9145,7-7/8"H x 5-118"W x 2-314"D ORDERED SEPARATELY 378 069 12K BRN RED ORG GLD N/A 1/2 N.C.SECURITY MON.(SHUNT) 4100,41000 If 27mm x 98mm x 56mm)REQUIRES 4905-9931 PLATE USE WITH RETROFIT OR HIGH CURRENT MODULE 1. FOR ADDITIONAL MOUNTING OPTIONS,DOWNLOAD DATA SHEET 4906-0002 FROM HTTP://WWW.SIMPLEX-FIRE.COM m 3 0 Q LL d LL_ Z3 N r N m N r NAC9 4009 NAC VOLTAGE DROP SUMMARY Standby Total Alarm Total Plan Module Qty Description Current Standby Current Alarm Circuit Description Load %Drop 9FL SOUTH SIG1 0.612A 2.59% Panel Equipment N9:V2 9FL EAST SIG2 1.144A 6.81% 4009-9201 1 1 4009/DNET NAC EXTENDER; 120 VAC 0.0850 0.0850 0.1850 0.1850 N9:V3 9FL WEST SIG3 1.270A 9.49% z Panel Totals 0.0850 0.1850 SPARE SIG4 0.000A 3 - 3.026A Total Notification Appliances 4906-9101 2 VIO MC NOWADDRESS,RED,WALL 110 0.0000 0.0000 0.2520 0.5040 ♦�W 4906-9101 11 VIO MC NON-ADDRESS,RED,WALL 15 0.0000 0.0000 0.0600 0.6600 N9:V7 Distributed Load Voltage Drop V 4906 9101 2 VIO MC NON-ADDRESS,RED,WALL 30 0.0000 0.0000 0.0940 0.1880 Q 0 4906 9101 9 VIO MC NON-ADDRESS,RED,WALL 75 0.0000 0.0000 0.1860 1.6740 Allowable%Drop: 17,9% Wire Res.Per Ft. 0.0031 !�75°Celsius Uj 111< J Peripheral Totals Wire Gauge: 14ga Min.Device Voltage: 16.vdc3:00 0 P 0.0000 3.0260 System Totals`: Standby 0.0850 Alarm 3.2110 Starting Voltage: 19.Svde %Voltage Drop 2.59% O o Circuit Capacity 2,A Normal Operationm w IF OPTIONAL SHIELDS ARE USED FOR ZDNet WIRING. M FOLLOW THESE PRECAUTIONS. Distance Device Voltage Voltage At O Z N o M Standby Standby Alarm Alarm Drop Z LU W a 1. IF ZDNet WIRING CONTINUES ON TO ANOTHER Device# PID Candela (Feet) Current p Device o DEVICE, TAPE SHIELDS TOGETHER. DO NOT Battery Set#1 (Cabinet/Charger#1) Current Total Current Total N9:V1.1 4906-9101 15cd 61 0.060 0.229 19.27 o TERMINATE SHIELD AT 4009 ZDNet. OR HOST IDNet CONTROL PANEL Select ALL Power Supplies on this battery set: N9:V1-2 4906-9101 75cd 14 0.186 0.277 19.22 (' W 0 2. IF ZDNet WIRING TERMINATES AT 4009, TAPE M 4009 0.0850 3.2110 N9:V1-3 49069101 15cd 25 0.060 0.333 19.17 O TO ADDITIONAL ZDNet DEVICES Z SHIELD. DO NOT TERMINATE SHIELD AT 4009 IDNet. N9:V1.4 4906-9101 15cd 51 0.060 0.429 19.07 o OR RETURN TO HOST IDNet CONTROL PANEL Sub Total 0.0850 3.2110 U J 4n in DNet CONTROLLER ADDRESS: VERIFY ADDRESS ON SITE. O O N9:V1-5 4906-9101 15cd 30 0.060 0.474 19.03 N9:V1-6 1 4906.9101 175Cd 28 0.186 0.506 18.99 Z = C") Lo Q N9:V3 Total 0.0850 3.2110 Totals: 209 Ft. 0.612A / w Z 0 t v J 1-- N9:V2 V Standby Time= 24 Hrs x 0.0850 =2.0400 Standby Ah N9:V1 V Alarm Time= 15 Min 0.25 x 3.211 =0.8028 Alarm Ah V 2.8428 N9:V2 Distributed Load Voltage Drop e N w Additional Spare Battery Capacity= 0% + 0.0000 °Celsius J Allowable%Drop: 17,9% Wire Res.Per Ft. 0.0031 @ 75 3 2'8428 Wire Gauge: 14ga Min.Device Voltage: 16.vdc Battery Discharge Factor= 20% + 0.5686 Starting Voltage: 19.5vdc %Voltage Drop 6.81/ N Minimum Battery Required 2081.9272 6.2AH(2x) 3.4113 Ckt Capacity 2.A y -_. Battery Supplied 2081-9272 6.2AH(2x) Normal Operation Distance Device Voltage Voltage At IDNET Device# PID Candela (Feet) Current Drop Device Ni 4906.9101 15cd 24 0.060 0.169 19.33 ❑ ❑ 0 ® N9:V2-2 4906.9101 15cd 18 0.060 0.288 19.21 8110 ❑ N9:V2-3 4906.9101 15cd 31 0.060 0.483 19.02 N9:V24 4906.9101 75cd 39 0.186 0.714 18.79 © ❑ 1111 ❑ ..® N9:V2-5 4906-9101 176cd 58 0.186 0.991 1 18.51 yAUX POWER �11-' ° u N9:V2-6 4906.9101 75cd 36 0.186 1.122 18.38 m OOO 0 ® N9:V2-7 4906-9101 30cd 30 0.094 1.197 18.30 PES& � o o N9:V2-8 4906.9101 15cd 43 0.060 1.279 18.22 a O o o B�n )(Do I N9:V2-9 4906-91 n- 110cd 31 0.252 1.327 18.17 BAER, Totals: 310 Ft. 1.144A o J 4OG9-9201 ZDNet NAC EXTENDER 00 v A� MIfWABCD 81991 W ® ® N9:V3 Distributed Load Voltage Drop Y NIQC41&n[R! WMUS 733-991 U ° 798 Allowable°%Dro 17.g% 75°Celsius o o pVuo p Wire Res.Per Ft. 0.0031 @ CONNECT TO + - + - cu 9r Wire Gauge: 14ga Min.Device Voltage: 16.vdc U 120VAC 60HZ ND ' INPUT 3A MAX. Starting Voltage: 19.5vdc %Voltage Drop 9,49% o s IP Ckt Capacity 2.A mi i9�3T9n Normal Operation o 6.2 Ah BATTERY 6.2 Ah BATTERY 0 a N 2081_9272 2081-9272 z y Distance Device Voltage Voltage At w Y a Device# PID Candela (Feet) Current Drop Device a o N9:V3-1 4906.9101 30cd 34 0.094 0.265 19.23 N N9:V3-2 4906-9101 110cd 93 0.252 0.937 18.56 a N9:V3-3 4906.9101 75cd 50 0.186 1.220 18.28 v N9:V3.4 4906.9101 15cd 17 0.060 1.297 18.20 CONNECT A 12 AWG COPPER GROUND WIRE FROM SAFETY N9:V3 5 4906 9101 75cd 28 0.186 1.414 18.09 DRAWN BY: R.HERMANT GROUND IN THE ELECTRICAL DISTRIBUTION PANEL TO CHECKED BY: M.GERRONE LL THE 4009 SAFETY GROUND STUD. N9:V3-6 4906.9101 15cd 80 0.060 1.656 17.84 NAC9 ISSUE DATE: 9/15/20 N9:V3-7 4906.9101 75cd 35 0.186 1.748 17.75 3 N9:V3-8 4906.9101 15cd 25 0.060 1.786 17.71 JOB#: SCALE:N.T.S. N9:V3-9 4906.9101 75cd 56 0.186 1.850 17.65 PROJECT#: 448:619576201 LOCATION: Totals: 418 Ft. 1.270A JOHNSON CONTROLS©2020 SYSTEM: FIRE ALARM SYSTEM SHEET: PANEL DETAIL, CALCULATIONS AND WIRING DETAILS d N N W t U x FA-501 0 0 Johnson Controls 2020.All rights reserved.Reuse,copying,modification or alteration of the drawings and other information contained herein is strictly prohibited.