Loading...
Plans (4) FPS2020-00072 OFFICE COPY RECEIVED • CITY OF TIGARD. - JUN 1 S 2�J2J co?I (91i REVIEWED FOR CODE COMPLIANCE CITY OF TIGARD �.1►� LO CDC 'rt Approvcds``�,� ] BUILDING DIVIS101'�1 � LU OTQ 2: O)W Johnson FIRE ALARM S (STEM Permit #:LINCOLN 2 CR MINING 410 F"p-s ao aQ :�0 0 0 7�a„ VALIDITY OF PERN11T �' UJ LL Address.: F' J 4 O C-sr,� .),�hLr„ 1' C , THE ISSUANCE OF A PERMIT Controls Siirtc #: BASED ON CONSTRUCTION DOCUMENTS AND OTHER o0c, Date; By: - DATA SHALL NOT PREVENT O G?1r THE CODE OFFICIAL FROM a„ wok REQUIRING THE CORRECTION aw,� - OF ERRORS. GSSG 105.4 �r S2 ?a DRAWING INDEX LEGENDS APPLICABLE CODES & STANDARDS JOHNSON CONTROLS CONTACTS N LL o cMa�u JURISDICTIONS WITHIN THE STATE MAY HAVE AMENDMENTS TO THE STATE ADOPTED CODE.CHECK Sales Representative Drawings Prepared By WITH THE LOCAL JURISDICTION AUTHORITY FOR MORE DETAILS. Oregon Structural Specialty Code,2019 Edition BRYAN ADAMS -_JNF�A72 LUCAS CONEDERA FIRE ALARM SYMBOL LEGEND BRYAN.ADAMs@Jc€.COM PLEASE rLUCAS.CONEDERA@JCI.COM SYMBOL DESCRIPTION BRAND MODEL BACKBOX WIRE Oregon Fire Code,2019 Edition PHONE:503-683-9000PHONE:503-683-9000 TYPE CONIPLETESEAN MALLON RECOLICENSE#5189LEA Oregon Mechanical Specialty Code,2019 Edition Project Coordinator ,�, Drawings Reviewed ByEXPIRES 10/01/2020 PANELS CO,��: :_KART BURGESS *L .. MARIA GERRONE NAC4 140091DNET NAC EXTENDER PANEL, 120 VAC,BEIGE S/MPLEX 4009-9201 SIMPLEX CABINET ly/q Oregon Electrical Specialty Code,2017 Edition KARI.BURGESS@JCI.COM F'� '' MARIA.GERRONE@JCI.COM Sheet List Table PHONE:503-683-9000 PHONE:503-683-9000 Sheet Number Sheet Title INITIATING DEVICES - National Fire Alarm Code(NFPA 72),2016 Edition NICET LEVEL IV#126987 FA-001 COVER SHEET O ADDRESSABLE PHOTOELECTRIC SMOKE SENSOR W1 STANDARD SIMPLEX 4098-9714 HEAD 4'OCT, 1-112"D M FA-101 DEVICE PLACEMENT PLAN&WIRING TYPICALS BASE 4098-9792 BASE FA-501 EXISTING 4009 NAC4 DETAIL AND CALCULATIONS ❑F ADDRESSABLE SINGLE ACTION MANUAL PULL STATION SIMPLEX 4099-9004 4"SQ,2-118"D W/ SINGLE GANG M COVER MODULES AND RELAYS MONITOR ZAM SIMPLEX 4090-9101 4"SQ.2-118'D W/ DBL.GANG COVER 2 NOTIFICATION APPLIANCES # CONVENTIONAL MULTI-CANDELA STROBE,WALL MOUNT,WHITE, V OCCUPANCY TYPE(S): SPRINKLER PROTECTION: CLEAR LENS,FIRE SIMPLEX 4906-9103 SINGLE GANG 1-112"D — B BUSINESS GROUP BUILDING IS FULLY SPRINKLED # CONVENTIONAL MULTI-CANDELA STROBE,CE/LING MOUNT, WHITE, V CLEAR LENS,FIRE SIMPLEX 4906-9104 SINGLE GANG 2-112"D # CONVENTIONAL MULTI-CANDELA HORN/STROBE,WALL MOUNT, SIMPLEX 4906-9129 4'SQ.1-1/2*D V CONWHITE, LENS,FIRE SCOPE OF WORK PROJECT DIRECTORY # CONVENTIONAL MULTI-CANDELA HORN/STROBE,CEILING MOUNT, SIMPLEX 4906-9130 4'SQ.1-112"D V C WHITE,CLEAR LENS,FIRE MODIFY EXISTING FIRE ALARM SYSTEM: PROVIDE NEW DEVICES AS SHOWN ON DRAWINGS. Site Johnson Controls District-448 10K'4vW END-OF-LINE RESISTOR 1 OK(EOL) SIMPLEX 4081-9008 ALL NEW WIRING TO BE CLASS B. LINCOLN 2 CR MINING SUITE 410 NOTE:EXISTING DEVICES SHOWN SHADED FOR REFERENCE. 10220 SW GREENBURG RD 6305 SW ROSEWOOD ST,SUITE A THE EXISTING FIRE ALARM SYSTEM SHALL NOT BE DISCONNECTED OR TAKEN OUT OF SERVICE WITHOUT WRITTEN PERMISSION FROM THE OWNER. IT TIIGARD,OR 97223 LAKE OOR 97035 PHONE:: 503-683-9000 IS THE CONTRACTORS RESPONSIBILITY TO COORDINATE WITH THE OWNER THE TIMING OF ANY EXISTING FIRE ALARM SYSTEM DEMOLITION WORK. FAX: 503-675-6521 SERVICE:503-683-9001 Installer DESIGN STATEMENT POINT MONITOR CORPORATION ACCEPTABLE 5863 LAKEVIEW BLVD STE 100 CABLE TYPES LAKE OSWEGO,OR 97035 FIRE ALARM WIRE LEGEND or = DESIGN IS FOR FIRE ALARM NOTIFICATION of SUITE 410. 0 CIRCUIT DESCRIPTION CONSTRUCTION GAUGE CIRCUIT PROPERTIES LL a. r O v V VISUAL 2 COND.SOLID 14 AWG X X m - _ CONDUIT SIZE MAX CONDUCTOR AREA CONDUIT SIZE MAX CONDUCTOR AREA 1/2' 1 0.122 SQ.INCH* 1-1/4' 0.598 SQ INCH* 3/4' 0.213 SQ INCH* 1-1/2' 0.814 SQ INCH* 1' 0.346 SQ INCH* 2' 1.342 SQ INCH* ABBREVIATIONS LEGEND DEVICE TAG LEGEND o '40%CONDUIT FILL PER N.E.C. _ STP=SHIELDED TWISTED PAIR _ Nr ITEMS SUCH AS CAPACITANCE BETWEEN CONDUCTORS AND WIRE GAUGE CAN BE CRUCIAL TO THE CIRCUIT DESIGN OF THIS SYSTEM `I' 0 INSTALLATION.THE INSTALLING CONTRACTOR IS RESPONSIBLE FOR SELECTING AND INSTALLING CABLE MANUFACTURER AND MODEL THAT MEETS OR EXCEEDS THE ABOVE REQUIREMENTS.RECOMMENDED CABLE MANUFACTURERS AND MODEL NUMBERS ARE AVAILABLE AC=ABOVE CEILING NEC=NATIONAL ELECTRIC CODE UPON REQUEST. AFF= ABOVE FINISHED FLOOR NFPA =NATIONAL FIRE PROTECTION ASSOCIATION o, AHJ= AUTHORITY HAVING JURISDICTION NIC =NOT IN CONTRACT Q c ALM= ALARM NPU =NETWORK PROCESSING UNIT ADDRESSABLE CARD(IDNET OR MAPNET) ANN= ANNUNCIATOR NTS =NOT TO SCALE 0 BMS=BUILDING MANAGEMENT SYSTEM PAP=PRE-ACTION PANEL NODE DESIGNATOR DEVICE ADDRESS N C=CEILING MOUNTED RC=EXISTING TO REMOVE AND COVER oCD=CANDELA RATING RD=EXISTING DEVICE TO BE RELOCATED 1:M2-1 t C DET=DETECTOR RL=RELOCATED DEVICE V -' DGP=DATA GATHERING PANEL RR=REMOVE EXISTING&REPLACE WITH NEW _ f E=EXISTING TO REMAIN SCC=STATUS COMMAND CENTER ADDRESSABLE DEVICES NUMBERING EOL=END OF LINE SLC =SIGNALING LINE CIRCUIT EPO=EMERGENCY POWER OFF SMK =SMOKE r. FAA =FIRE ALARM ANNUNCIATOR SUPV = SUPERVISORY FACP=FIRE ALARM CONTROL PANEL TAC = TRUEALERT ADDRESSABLE CONTROLLER FATC=FIRE ALARM TERMINAL CABINET TRBL=TROUBLE OFFICE COP ■ W FBO=FURNISHED BY OTHERS TS=TAMPER SWITCH F- Q FCC=FIRE COMMAND CENTER TYP=TYPICAL CC it FSD=FIRE SMOKE DAMPER UON=UNLESS OTHERWISE NOTED 4009 NAC PANE CIRCUIT DESIGNATOR `jam FTR=FIRE ALARM TRANSPONDER VCC = VOICE COMMAND CENTER (WHEN APPLICABLE) V=VISUAL OR AN,H=AUDIBLE ONLY) C� H=HIGH HUMIDITY VT= VALVE TAMPER NODE DESIGNATORDEVICE DESIGNATOR a HT=HEIGHT W= WATTAGE _� (- Z =D HVAC=HEATING VENTILATION&AIR CONDITIONING W/= WITH Z m M 1:NAC1:V2-1 N N IMS=INFORMATION MANAGEMENT SYSTEM W/0=WITHOUT CV MAX=MAXIMUM WF=WATERFLOW W MIN=MINIMUM WG=WIRE GUARD flo- VISUAL,AUDIBLE OR A/V DEVICE M NIA =NOT APPLICABLE WP=WEATHERPROOF J W IX A2 NAC = NOTIFICATION APPLIANCE CIRCUIT XP =EXPLOSION PROOF NDU= NETWORK DISPLAY UNIT CV O ca SYSTEM SEQUENCE OF OPERATIONS 0 R 0 04 ZC-4ca 75 c� E co UJ LL_ CONTROL UNIT ANNUNCIATION NOTIFICATION REQUIRED FIRE SAFETY CONTROL SUPPLEMENTARY co o GENERAL NOTES TYPICAL RISER DIAGRAM LU 1. THESE DRAWINGS DEPICT GENERAL LOCATIONS OF LIFE SAFETY EQUIPMENT&FIELD DEVICES.EXACT ROUTING OF CONDUITS IS TO BE RISER NOTES: p v DETERMINED IN THE FIELD BY THE INSTALLING CONTRACTOR TO SUIT CONDITIONS. ALL CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. 1. RISER IS A DIAGRAMMATICAL REPRESENTATION OF THE M 2. SHOULD ANY CONDITIONS EXIST THAT DIFFER FROM WHAT IS INDICATED ON THESE DRAWINGS WHICH CAUSE MAJOR DEVIATIONS IN SYSTEM ARCHITECTURE IN BUILDING CROSS SECTION.IT IS G�J�c�J�C�J� P P P THE WORK SHOWN,THE CONTRACTOR SHALL CONTACT JOHNSON CONTROLS IN A TIMELY MANNER SO AS NOT TO IMPAIR THE NOT INTENDED TO REPRESENT ACTUAL WIRE RUNS,PANEL t SYSTEM INPUTS A B C D E F G H I J K L M N 0 P Q R S T U V W X Y Z AA AB AC AD AE AF AG AH REMARKS CONSTRUCTION SCHEDULE. CONFIGURATIONS OR PENETRATIONS.REFER TO FLOOR j 1 SMOKE SENSOR DETECTOR • • 1 + Ill r- 3. CONTRACTOR IS RESPONSIBLE FOR MAKING AND OBTAINING APPROVAL FOR ALL NECESSARY ADJUSTMENTS IN CIRCUITING AS PLANS AND PANEL DETAILS FOR CIRCUIT ROUTING AND Z 2 MANUAL PULL STATION + • • • • • • + 2 g REQUIRED TO ACCOMMODATE THE RELOCATION OF EQUIPMENT AND/OR DEVICES WHICH ARE AFFECTED BY ANY AUTHORIZED CHANGE. CONFIGURATION INFORMATION, 3 DUCT SENSOR DEFECTOR • • • • • • • • 3 a ALL CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. 2. ALL WIRING SHALL COMPLY WITH APPLICABLE ELECTRICALW 4, A STAMPED SET OF APPROVED FIRE ALARM DRAWINGS SHALL BE AT THE JOB SITE AND SHALL BE USED FOR INSTALLATION. CODES.REFER TO'APPLICABLE CODES&STANDARDS'ON 4 ATRIUM BEAM DETECTOR • • + • • + • • • • 4 U) 5 MAIN FLR. ELEV. LOBBY SMOKE DETECTOR + + • • • • + • • • • • 5 W 5. THE POWER CIRCUIT TO THE FACP AND TO THE FIRE ALARM POWER SUPPLIES SHALL BE ON A DEDICATED 120V,20A BRANCH CIRCUIT SHEET FA-001 FOR SPECIFIC CODE REFERENCES. 6 ELEVATOR LOBBY SMOKE DETECTORS EXC. MAIN FLR. • • • • • + • • • • + 6 - BREAKER,AND SHALL HAVE A RED MARKING,LOCK-ON PROVISION AND SHALL BE IDENTIFIED AS'FIRE ALARM CIRCUIT CONTROL.' THE 3. DEVICES ARE TYPICAL.SEE FLOOR PLAN FOR QUANTITY& 7 ELEVATOR MECH. ROOM SMOKE DETECTOR • • • • • * • • • • 7 � LOCATION OF THE CIRCUIT DISCONNECT MEANS(CIRCUIT BREAKER)SHALL BE PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL LOCATIONS. $ $ c UNIT. 9 9 6. UPDATE THE AS-BUILT DRAWING SET DAILY WITH JOB PROGRESS. RETURN THE AS-BUILT DRAWING SET TO JOHNSON CONTROLS NOa 10 WATERFLOW SWITCH • • • • • • • • 10 LATER THAN 7 DAYS AFTER FINAL TEST. 11 TAMPER SWITCH • • • • • • 11 L) 7. THE CONTRACTOR WILL MAINTAIN ALL AREAS OF THE BUILDING IN A NEAT AND WORKMANLIKE MANNER. 12 12 w 8. DO NOT APPLY POWER EXCEPT IN THE PRESENCE OF A FACTORY TRAINED JOHNSON CONTROLS TECHNICAL REPRESENTATIVE. EXISTING IDNET DEVICES V V V 13 FIRE ALARM AC POWER FAILURE • • • • • 13 n a 9. ANY SMOKE DETECTOR HEAD INSTALLED BEFORE THE BUILDING IS CLEANED AND ACCEPTED SHALL BE COVERED TO PROTECT FROM V 14 FIRE ALARM SYSTEM LOW BATTERY • + • • • 14 0 1:NAC4:V1 �r DUST. ANY FALSE ALARMS DUE TO DIRT CONTAMINATED HEADS SHALL BE THE RESPONSIBILITY OF THE FIRE ALARM INSTALLER. (1:NAC4:V1) 15 OPEN CIRCUIT • • + + • 15 w Y 10. THE FIRE ALARM INSTALLER WILL MAINTAIN THE FIRE RESISTANCE INTEGRITY OF ALL WALL,CEILING,AND ROOF ASSEMBLIES ANY TIME C 10K 16 GROUND FAULT • • • • • 16 M ce M THAT WORK IS NOT ACTIVELY BEING PERFORMED. SQ cliN 11. INSTALLATION OF DEVICES SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. POWER LIMITED AND NONPOWER M 17 NOTIFICATION APPLIANCE CIRCUIT - CLASS B STYLE Y: 17 LIMITED FIELD WIRING MUST BE INSTALLED WITHIN THE FACP ENCLOSURE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND V V V V 1$ WIRE-TO-WIRE SHORT . + + + + 1$ Q APPLICABLE ELECTRICAL CODES.REFER TO'APPLICABLE CODES&STANDARDS'FOR SPECIFIC CODE REFERENCES. NAC4 1:NAC4:V2 - 10K 20 20 (1:NAC4:V2) 19 19 UJ 12. ALL RING SHALL E INSTALLED RDING TO APPLICABLE TRICAL CODES. Z 13. FIRE AILARM C R U$S SHALL BE IDENTIFIED N ACCORDANCE WITHCA PLICABLE ELECTRICAL.CODES. MARX ALL FIRE ALARM WIRES IN _�_�,��� 4TH FLOOR 22 22 21 21 DRAWN BY: L CONEDERA CL ACCORDANCE WITH APPLICABLE ELECTRICAL CODE SECTIONS FOR POWER LIMITED AND NON-POWER LIMITED WIRE. S V V V V 23 23 CHECKED BY: M.GERRONE F- P 1:NAC4:V3 1 NAC4:V3) ISSUE DATE: 6/4120 14 FIRE ALARM CABLE INSTALLED IN DUCTS,PLENUM,AND OTHER SPACES USED FOR ENVIRONMENTAL AIR SHALL BE TYPE FPLP. M M M f 24 24 15. FIRE ALARM CABLE INSTALLED IN THE VERTICAL RUNS AND PENETRATING MORE THAN ONE FLOOR OR CABLES INSTALLED IN VERTICAL 10K 251 1 1 251 JOB#: RUNS IN SHAFTS SHALL BE TYPE FPLR. 26 26 PROJECT#: 448:618834101 16. FIRE ALARM CABLE INSTALLED IN UNDERGROUND CONDUIT OR OTHER WET LOCATIONS SHALL BE UL LISTED FOR WET LOCATIONS. V V V V 27 27 JOHNSON CONTROLS p 2020 17. FIRE ALARM CIRCUITS EXTENDING BEYOND ONE BUILDING AND RUN OUTDOORS SHALL BE INSTALLED IN ACCORDANCE APPLICABLE M 1:NAC4:V4 (1:NAC4:V4) 28 28 ELECTRICAL CODES,WHERE APPLICABLE. 10K 29 29 SYSTEM: 18. ALL WIRING,INCLUDING SHIELDS MUST BE DRY AND FREE OF SHORTS AND GROUNDS. C 301 301 FIRE ALARM SYSTEM 19. ALL SHIELDED WIRE MUST HAVE SHIELD CONTINUITY AT FULL LENGTH OF THE WIRE. 120VAC 1311 Ti 20. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. A B C D E F G H I J I K I L M N 0 1 P Q R S T U V W X Y Z AA AB AC AD AE AF AG AH SHEET: 21. 120VAC IS NOT PERMITTED IN THE SAME CONDUIT WITH LOW VOLTAGE WIRING. 22. MAINTAIN MAXIMUM CONDUIT FILL RATIO AS PER APPLICABLE ELECTRICAL CODES REQUIREMENTS. 23. EXISTING CONDUITS MAYBE USED BY THE INSTALLATION CONTRACTOR AS DEEMED NECESSARY;HOWEVER,ANY EXISTING CONDUIT FOURTH FLOOR COVER SHEET WILL BE USED ONLY IF CONDUITS MEET CURRENT STANDARDS AND CODES.JOHNSON CONTROLS MAKES NO STATEMENTS WRITTEN OR VERBAL AS TO THE CONDITION OF EXISTING CONDUITS. N EXISTING IDNET DEVICES U) LU - IMPORTANT NOTICE TO USER:This information may not be sold or transferred to any third party,used on other projects or additions to the project for which it was prepared,or used for completion of this project by any third party. Johnson Controls disclaims all liability for the use or reuse of altered files by the user or FA-001 x any third party and such use will be a user's sole risk. User shall,to the fullest extent permitted by law,defend,indemnify,and hold Johnson Controls harmless M from any and all claims for loss,damage or injury arising directly or indirectly from any such unauthorized use. ©Johnson Controls 2020.All rights reserved.Reuse,copying,modification or alteration of the drawings and other information contained herein is strictly prohibited. GENERAL NOTES: 1. ALL CEILINGS ARE ASSUMED TO BE 10'A.F.F.,SMOOTH CONSTRUCTION UNLESS NOTED OTHERWISE. 1 2 3 9% 2. EXISTING DEVICES SHOWN SHADED FOR REFERENCE. , o_ CP� AREA OF WORK w C 0 Z or � - xa 1=0 tz N � OFFICE 7OFFICE OFFICE OFFICE OFFICE 0o 416 415 414 413 412 1:NAC4:v2-9 C oda 15 ood CONFERENCE � 3 408 u WcDcj V 0 Ir3v /OFFICE CLOS T DECK 300 15 y ooc 417 V HALL 409 1:NAC4:V2-8 BREAK 'o �5� 11 1:NACa:V2-5 15 V —- 404 II NA 4N2-1 1:NAC4:V2-11 P RB OFFICE OFFICE STORAGE 15 15 418 429 470 SEAN MALLON V INTERVIEW/ OFFICE ER VIEW TESTING LICENSE#5189LEA 1:NAC4:V2-4 07 406 EXPIRES 10/01/2020 42Z 11 75 1:NAC4:V2-7 V ITE 15 30 RECEPTION TESTING S 405 ORAGE v INTERVIEW/ 405 OFFICE 00 1.NAC4:V2-6 V 401 4:)::5:] VCT 75 (I:NAC OFFICE WAITI G I P RB 75 ,OKAC4:V4) 419 428 SKILLS 404 1:NA(4:V2-1 ) __---- v LAB 1:NAC V2 TORAGE V 402 LOSET tOKF-4031HUDDLE HUDDLE C _ _ 403 - VCT_ 406 407 P RB CPT CPT OPEN 1:NAC4:V1-8 1:NAC4:V1-3 15 P RB P RB 1:NAC4:V2-3 OFFICE 1- 8 15 v O 15 RECEPTION t:N :V4-7 OFFICE 30 4 6 v C F 1:M1-126 401 420 1: 1-127 LVP V P RB V 1:NAC4:V4-6 30 C SERVER 402 V :V1-7 1:NA y VCT 15 1 15 . 1 P RB H� ER ' V y 1:NAC4:V1-2 -- V OFFICE 422 424 15 15 30 C 1:NAC4:V4-5 421 i:M C4:V1-6 V 1:NAC4: 5 O 15 1:NAC4:V2-1 1:M1-125 OPEN OFFICE 30 15 CONFERENCE 408 1:NAC4:V2-2 ®P 412 1:M1-1 CPT BREAK V CPT P RB 423 STORAGE 425 HALL 110 °WLZ 1:NAC4:V4-4 i:M1-121 V 411 NAC4 CPT P RB o L _ _ - - - 1: 1-122 i:NACa:V4-1 N OR 1:M1-124 F 15 0,13E 0,13E COPY BREAK V 415 E JV 1:M1-1130 C 1:N C4 Vl�l15 V V - - - -- –.". --_ - - -Fill 11111 - o / 1:NAC4:V3-1 V CONFER C 30 410 ¢ V IN TER VI W Vk30 -0 1:NAC4:V42 CPT 75 407 15 P RB V 1:NAC4:V3-2 RVER 1:NAC4V 3 RECEPTIONOW 15 m V STORAGE 408 o OFFICE 409 - --- -- - OPEN 1:NAC4: i 1 t0 LV 1:NAC4:V4-3 END OF LINE RESISTOR CODES o 414 SITE V E v c 50 Rill 15 V 1 NAC4:V3 I_ 1:NAC4:V3-8 NOTE:REFER TO PANEUMODULE AND DEVICE V INTERVI W 30 OPEN OFFICE I INSTALLATION INSTRUCTIONS FOR PROPER 0 7 406 1:NAC4:V3 6 409 TERMINATIONS. CPT REF. BAND NUMBER O t MODEL 4 WATTS CIRCUIT TYPE FIRE ALARM PANEUMODULE CONFERENCE P RB — NUMBER 3 1 2 1 3 1 4 H5 404 4081-9001 733-892 2.2K RED RED RED GLD N/A 1/2 ANNUNCIATOR(4300) 4004,4010(TROUBLE) NOME OFFICE N.O.INITIATING PULL,SMOKE, 4004',4004R,4005',4006,410 , 5 W J1:NA :V3-9 405 4081-9002 733-893 3.3K ORG ORG RED GILD N/A 1 HEAT,WATERFLOW,TAMPER,ETC. 4120,41000,ZAMs10 v 1 24 PT. I/O SWITCH SUPV. 4605-7401,4100 SERIES ISE p (1.NAC4:V3) CURRENT LIMITED N.O.INIT., 40901DNET IAM EOLR)10 4081-9003 733 896 4.7K YEL VT RED GLD N/A 1/2 NOTIFICATION(DACT) 2080-9024CD- - - -- --- - - O-- — -- - -- - --- ---"- 4004,4005,4090-9001 IDNET IAM, a N/0 INITIATING PULL,SMOKE, Z 4081-9004 733-886 6.8K BLU GRY RED GLD N/A 1/2 2190.9173 MAPNETII 2 PT 1/0 HEAT,W.FLOW,TAMPER,ETC 4-20MA ZAM(TROUBLE) N Z CO M CURRENT LIMITED N.O.INITIATING Z N E 4081-9005 733-984 1.8K BRN GRY RED GLD N/A 1/2 (INLINE) 4090-9001IDNET IAM r2 LU 04 4005',4090-9001 IDNET IAM W w 4081-9006 733-890 560 GRN BLU BRN GLD N/A t N.C.INITIATING(EOLR) 4100,41000 V DEVICE PLACEMENT PLAN - 4TH FLOOR 4081-9007 733-891 1.2K BRN RED RED GLD N/A 1 N.C.INITIATING(EOLR) 4005 O NCD O 0 4004,4005,4006,4008,4009,4010, a SCALE: 118" = V-0" 4081-9008 733-894 10K BRN BLK ORG GLD NIA 1l2 NOTIFICATION 4100,41000 Z e SCALE:1/8"=1'-0" IN FEET 4081-9009 733-912 20 RED BLK BLK GLD N/A 1 TO MR-101 RELAY COIL 4005 8 POINT 1/0 _j II v 0 4' 8' 15 N.C. INIT.(ACROSS CONTACTS) 4005',4090-9001 IDNET IAM Z V N Q 4081-9010 733-973 1K BRN BLK RED GLD N/A t 24 PT.1/0(ACROSS CONTACTS 4605-7401,4100 SERIES MEMM Z N CURRENT LIMITED N.O.INIT. 4090-9001 IDNET IAM J CT ~ 3 (IN SERIES WITH CONTACT) U 4081-9011 733-974 100 BRN BLK BRN GLD N/A 1/2 ANNUNCIATOR(N2) 4006,4008,4010 E a 4081-9012 733-985 22K RED RED ORG GLD N/A 112 SPEAKER CIRCUIT 4003 4081-9013 734-086 4.99K YEL WHT WHT BRN BRN 1/2 LL 4081-9014 734-092 2.4K RED YEL RED GLD N/A 1/2 N.C.INITIATING(SECURITY 4090-9001 IDNET IAM 9 MONITORING EOLR) CURRENT LIMITED N.O.INIT. o 4081-9015 734-093 1.5K BRN GRN RED GOLD N/A 1/2 (SECURITY MONITORING EOLR) 4090-9001 IDNET IAM H 4081-9016 734-149 150K BRN GRN YEL GLD N/A 1/2 0 4081-9017 734-171 3.9K ORG WHT RED GLD N/A 1 4081-9018 734-168 1 10K BRN BLK ORG GLD N/A 1 70VRMS CONSTANT SUPV.NAC 4100-1260 378-090 8.2K GRY RED RED GLD N/A 1/2 SECURITY MONITORING(EOLR) 4100,41000 378-046 5.6K GRN BLU RED GLD N/A 1/2 N.O.SECURITY MON.(SERIES) 4100,41000 378-069 I 12K BRN RED ORG GLD I N/A 1 1/2 N.C.SECURITY MON.(SHUNT) 4100,41000 USE WITH RETROFIT OR HIGH CURRENT MODULE Cw DEVICE MOUNTING HEIGHT REFERENCE TrueAlert CONVENTIONAL APPLIANCES TrueAlert CONVENTIONAL APPLIANCES TrueAlert CONVENTIONAL APPLIANCES } PER NFPA 72 SIMPLEX 4906 SERIES WALL MOUNTED VISUAL SIMPLEX 4906 SERIES WALL MOUNTED MULTI-CANDELA AUDIBLE 1 VISUAL SIMPLEX 4906 SERIES CEILING MOUNTED AUDIBLE/VISUAL m 0 a VISUAL APPLIANCE MOUNTING HEIGHT CONSIDERATIONS IN SLEEPING ROOMS STANDARD ELECTRICAL 1. MIN DISTANCE IN SLEEPING ROOMS IS 24"(610mm)FROM CEILING TO TOP A/C SUPPLY STANDARD ELECTRICAL ELECTRICAL BOX PROVIDED = N BOX MOUNTING 4"SQUARE BOX MOUNTING 4'SQUARE o g OF LENS FOR 11 OCD STROBES WITHIN 16'OF THE PILLOW OR RETURN THE 4"REQUIREMENT FOR SMOKE DETECTORS HAS BOX, 1-1/2"DEEP ELECTRICAL BOX BY ELECTRICAL CONTRACTOR. F 2. 177CD STROBES,USED IN SLEEPING ROOMS,CAN BE WITHIN THE 24" DIFFUSER BEEN REMOVED FROM THE 2010 EDITION OF NFPA 72 ELECTRICAL BOX BOX, 1-112"DEEP NOTE:DO NOT BRING CONDUIT ° (610mm)MINIMUM DISTANCE FROM THE CEILING.THE HIGHER INTENSITY IS ° SURFACE MOUNT ° SURFACE MOUNT O THROUGH THE REAR OF THE TO COMPENSATE FOR A POSSIBLE SMOKE LAYER. 3'(914mm) a" NOTE:MEASUREMENTS ADAPTER SKIRT 1 5l8" ADAPTER SKIRT 15/15" O ELECTRICAL BOX. c MINIMUM CEILING (102mm) SHOWN ARE TO THE CLOSEST ° (41mm)DEEP.CONDUIT ° (41mm)DEEP.CONDUIT EDGE OF THE DETECTOR. ° CUTOUTS ARE PROVIDED ° CUTOUTS ARE PROVIDED _ —� ON ALL FOUR SIDES. ON ALL FOUR SIDES. e' FOR CEILING HEIGHTS LESS THAN 86' NFPA 72 AUDIBLE APPLIANCE 6"MIN CEILING MOUNTS 4" ° SURFACE MOUNTING o SURFACE MOUNTING ° ¢ (2180mm),THE VISUAL LENS MOUNTING (152.4mm MIN)BELOW FINISHED CEILING SMOKE/HEAT (102mm) o HEIGHT SHALL BE WITHIN 6"(150mm)OF THE DETECTOR CEILING. E + e e w f♦ ACCEPTED HERE 12"(305mm) Q rHOUSING CANDELA INTENSITY + + CANDELA INTENSITYHEAT DETECTORS MAXIMUM TO TOP OF SENSOR F R E PLUG ACCESSIBLE PLUG ACCESSIBLE AUDIBLEIVISUAL AUDIBLE ONLY NEVER HERE TO NEXTFROM REAR OF FROM REAR OF TO EXIT DOOR HOUSING STROBE + + N a N 8 VISUAL ONLY WALL MOUNTED TO NEXT o DEVICE OR 10K m APPLIANCES 5 (MAX.) CIRCUIT SMOKEIHEAT DETECTOR DEVICE OR TO NEXT INTENSITY () () RESISTOR (1524mm) TOP OF LENS: NAC CIRCUIT TOP OF LENS: DEVICE OR EOL SELECTION PLUG, o SYNCHRONIZE MORE 96"(2044mm)A.F.F MAXIMUM (+) (+) ( 96"(2044mm)A.F.F MAXIMUM NAC CIRCUIT EOL s° TERMINATION VIEW:DEVICE MOUNTING PLATE I� RESISTOR (+) (+) ACCESSIBLE ONLY THAN TWO APPLIANCES FOR CEILINGS<86"(2180mm)A.F.F.: TERMINATION VIEW:REAR OF DEVICE FOR CEILINGS<86"(2180mm)A.F.F.: RESISTOR FROM REAR OF CLASS B WIRING DRAWN BY: L.CONEDERA Of IN ANY FIELD OF VIEW. MAGNETIC 5" <=6"(150mm)FROM CEILING CLASS B WIRING <=6"(150mm)FROM CEILING TERMINATION VIEW:REAR OF DEVICE a HOUSING a 96"MAX(NFPA,ADA) DOOR (127mm) CLASS B WIRING CHECKED BY: M.GERRONE 90"MIN(2286mm MIN)ABOVE FINISHED BOTTOM OF LENS: WIRING NOTES BOTTOM OF LENS: (2440mm MAX) HOLDER MAGNETIC TEST ISSUE DATE: 6/4/20 5 ABOVE FINISHED FLOOR FLOOR(OTHER MOUNTING HEIGHTS SIDE WALL 80"(2032mm)A.F.F.MINIMUM 80"(2032mm)A.F.F.MINIMUM WIRING NOTES LOCATION STROBE INTENSITY WIRING NOTES TO TOP OF LENS SHALL BE PERMITTED BY THE AHJ �r FINISHED 1. MAINTAIN CORRECT POLARITY ON TERMINAL SETTING VIEWABLE JOB#: REF.80"MIN(IBC) PROVIDING IT MEETS THE SOUND LEVEL °� T "' "� 1. MAINTAIN CORRECT POLARITY ON TERMINAL DOOR WALL MOUNTING OPTION B CONNECTIONS. MOUNTING OPTION B THROUGH THE LENS 1. MAINTAIN CORRECT POLARITY ON TERMINAL PROJECT#: 448:618834101 (2032mm MIN)REF.96" 80"MIN(ADA) OUTPUT REQUIRED.) WIDTH 2. ALWAYS CUT CONDUCTORS AND SECURE UNDER CONNECTIONS. CONNECTIONS. JOHNSON CONTROLS©2020 MAX(IBC)(2440mm MAX) (2032mm MIN) FIRErMANUAL PULL LESS 3" TERMINALS.NEVER LOOP WIRES UNDER 2. ALWAYS CUT CONDUCTORS AND SECURE UNDER MOUNTING OPTION A 2. ALWAYS CUT CONDUCTORS AND SECURE UNDER ABOVE FINISHED FLOOR 80"MIN(NFPA) PHONE I STATION (76mm) TERMINALS. TERMINALS.NEVER LOOP WIRES UNDER TERMINALS.NEVER LOOP WIRES UNDER SYSTEM: (2032mm MIN) JACK I 3. ANY WIRE SPLICES TO BE MADE BY LISTED AND TERMINALS. TERMINALS. FIRE ALARM SYSTEM TO BOTTOM OF LENS AHJ APPROVED METHODS. 3. ANY WIRE SPLICES TO BE MADE BY LISTED AND 3. ANY WIRE SPLICES TO BE MADE BY LISTED AND ® ® AHJ APPROVED METHODS. AHJ APPROVED METHODS. SHEET: NOTE:REFER TO THE PROPER DEVICE ® MOUNTING OPTIONS MOUNTING OPTIONS INSTALLATION INSTRUCTIONS 48"MAX(ADA)(1219 mm) OPTION' DESCRIPTION NOTE OPTION' DESCRIPTION NOTE MOUNTING OPTIONS FOR BACKBOX MOUNTING 48"MAX(NFPA,ADA)(1219mm MAX) OPTION DESCRIPTION NOTE DEVICE PLACEMENT PLAN HEIGHT. 42'MIN(NFPA)(1067mm MIN) A SINGLE GANG BOX,1-112"(64mm)DEEP BY OTHERS.WHEN SURFACE A SINGLE GANG BOX,1-1/2"(64mm)DEEP BY OTHERS.WHEN SURFACE MOUNTING USE &WIRING TYPICALS MEASUREMENTS SHOWN ARE B 4"(102mm)SQUARE BOX, 1-1/2"(38mm)DEEP,MINIMUM MOUNTING USE 4905-9937(RED)OR B 4"(102mm)SQUARE BOX,1-1/2"(38mm)DEEP,MINIMUM 4905-9937(RED)OR 4906-9940(WHITE)SKIRT A 4"(102mm)SQUARE BOX, 1-1/2"(38mm)DEEP,MINIMUM BY OTHERS TO TOP OF PULL HANDLE C 2 GANG BOX, 1-1/2"(38mm)DEEP 4906-9940(WHITE)SKIRT C 2 GANG BOX, 1-1/2"(38mm)DEEP a FINISHED SURFACE MOUNT 4"(102mm)SQUARE BOX,1-112"(38mm)DEEP, 4905-9915(WHITE)OR 4905-9916(RED)ADAPTER FLOOR SIMPLEX 2975-9145,7-7/8"H x 5-1/8"W x 2-3/4"D SIMPLEX 2975-9145,7-7/8"H x 5-1/8"W x 2-3/4"D B MINIMUM RECOMMENDED,ORDERED SEPARATELY w D (127mm x 98mm x 56mm)REQUIRES 4905-9931 PLATE ORDERED SEPARATELY D (127mm x 98mm x 56mm)REQUIRES 49059931 PLATE ORDERED SEPARATELY t 1. FOR ADDITIONAL MOUNTING OPTIONS,DOWNLOAD DATA SHEET 4906-0002 FROM HTTP:/NVWW.SIMPLEX-FIRE.COM a 1. FOR ADDITIONAL MOUNTING OPTIONS,DOWNLOAD DATA SHEET 4906-0002 FROM HTTP://WWW.SIMPLEX-FIRE.COM 1. FOR ADDITIONAL MOUNTING OPTIONS,DOWNLOAD DATA SHEET 4906-0002 FROM HTTP:/ANWW.SIMPLEX-FIRE.COM 2. 49059928 ADAPTER PLATE REQUIRED WITH OPTIONAL 49059927 RED WIRE GUARD a FA-101 x ZD ©Johnson Controls 2020.All rights reserved.Reuse,copying,modification or alteration of the drawings and other information contained herein is strictly prohibited. i GENERAL NOTES: 1. EXISTING DEVICES SHOWN SHADED FOR REFERENCE. o u rna coo a U7)Lf w Z 05, =-a Qdt[ o w N2_ OOCJ OAC o�q ED 0 LC �(nU 0- I,►u LINCOLN 2 4FL N ELEC NAC4 4009 NAC C3 gcn v Standby Total Alarm Total Module Qty Description Current Standby Current Alarm Panel Equipment 4009-9201 1 1 4009 IDNET NAC EXTENDER, 120 VAC 0.0850 0.0850 0.1850 0.1850 SEAN MALLON Panel Totals 0.0850 0.1850 LICENSE#5189LEA Notification Appliances Setting EXPIRES 10/01/2020 IF OPTIONAL SHIELDS ARE USED FOR ZDNet WIRING. 4906-9101 7 VIO MC NON-ADDRESS,RED, WALL 15 0.0000 0.0000 0.0600 0.4200 ,. FOLLOW THESE PRECAUTIONS. 4906-9101 1 VIO MC NON-ADDRESS,RED, WALL 30 0.0000 0.0000 0.0940 0.0940 4906-9101 1 VIO MC NON-ADDRESS,RED, WALL 75 0.0000 0.0000 0.1860 0.1860 1. IF ZDNet WIRING CONTINUES ON TO ANOTHER DEVICE, TAPE SHIELDS TOGETHER.DO NOT TERMINATE SHIELD FROM PREVIOUS IDNet DEVICES 4906-9103 9 VIO MC NON-ADDRESS,WHT,WALL 15 0.0000 0.0000 0.0600 0.5400 AT 4009 ZDNet. OR HOST ZDNet CONTROL PANEL 4906-9103 2 VIO MC NON-ADDRESS, WHT, WALL 30 0.0000 0.0000 0.0940 0.1880 2. IF IDNet WIRING TERMINATES AT 4009,TAPE SHIELD.DO TO ADDITIONAL ZDNet DEVICES 4906-9104 2 VIO MC NON-ADDRESS, WHT,CEILING 15 0.0000 0.0000 0.0750 0.1500 NOT TERMINATE SHIELD AT 4009 ZDNet OR RETURN TO HOST ZDNet CONTROL PANEL 4906-9127 1 AN MC NON-ADDRESS,RED, WALL 15 0.0000 0.0000 0.0750 0.0750 IDNet CONTROLLER ADDRESS: 1:M1-121 4906-9127 2 AN MC NON-ADDRESS,RED, WALL 30 0.0000 0.0000 0.1160 0.2320 #:NAC4:V4 V 4906-9129 3 AN MC NON-ADDRESS,WHT,WALL 110 0.0000 0.0000 0.2850 0.8550 V 1:NAC4:V3 4906-9129 2 AIV MC NON ADDRESS,WHT,WALL 15 0.0000 0.0000 0.0750 0.1500 V� 1:NAC4:V2 ' 4906-9129 1 AN MC NON ADDRESS, WHT, WALL 30 0.0000 0.0000 0.1960 0.1160 1:NAC4:V1 V1 4906-9129 3 AN MC NON-ADDRESS,WHT,WALL 75 0.0000 0.0000 0.2210 0.6630 4906-9130 2 AIV MC NON ADDRESS, WHT,CEILING 15 0.0000 0.0000 0.0860 0.1720 4906-9130 2 AN MC NON-ADDRESS,WHT,CEILING 30 1 0.0000 0.0000 0.1320 0.2640 Peripheral Totals 0.0000 4.1050 • System Totals*: Standby 0.0850 Alarm 4.2900 m m mm m ® Standby Standby Alarm Alarm N=a m<m Battery Set#1 (Cabinet/Charger#1) Current Total Current Total IDNET Select ALL Power Supplies on this battery set: ro4009 0.0850 4.2900 Sub Total 0.0850 4.2900 � 6�] bol - � - - � - - - p� Total 0.0850 4.2900 @ �® O O 8 Qa AUX POWER o O O Standby Time= 24 Hrs x 0.0850 =2.0400 Standby Ah t°°fPX IN T Alarm Time= 5 Min 0.08333 x 4.29 =0.3575 Alarm Ah ITT IN MTI vc ° O b iE 2.3975 o POS � ° ° O Additional Spare Battery Capacity= 0% + 0.0000 Fe WT BATTERY p O 2.3975 4009-9201 IDNet NAC EXTENDER + u Battery Discharge a Factor= air� oT�' 20°I° + 0.4795 Minimum Battery Required 2081-9272 6.2AH(2x) 2.8770 A L400 Battery Supplied 2081-9272 6.2AH(2x) INTERNAL BATTERY HARNESS 733.991 *System Totals represent total system current requirements.Those currents may be distributed between multiple battery sets or power supplies as shown above. rn HARNESS 733945 c Q GROUND 'c NEUrR& rCONNECT TO 120VAC 60HZ INPUT 3A MAX. �.,�,■ HOT 129V �! N TERMINAL o STRIP C PART of 733-991 6.2 Ah BATTERY 6.2 Ah BATTERY VOLTAGE DROP SUMMARY Class B 0 2081-9272 2081-9272 z Spare O Plan Circuit Circuit Description toad %Drop Capacity {�, 1:NAC4:Vl 4FLHORAVSTROBES SIGt 0.694A 3.45% 65.30% �C W o `°:pJ 1:NAC4:V2 4FL SUITE 400 NOTIFICATION SIG2 1.007A 6.50% 49.65% ~ 0 0 1:NAC4:V3 14FL SUITE 450 NOTIFICATION SIG3 1.211A 6.66% 39.45% 0 1:NAC4:V4 4FL SUITE 410 NOTIFICATION SIG4 1.193A 7.12% 40.35% CD 0 CONNECT A 12 AWG COPPER GROUND WIRE FROM SAFETY 4.105A Total CD GROUND IN THE ELECTRICAL DISTRIBUTION PANEL TO Z THE 4009 SAFETY GROUND STUD. in M «S Z N U 1:NAC4:V4 Distributed Load Voltage Drop LU W C3 2 Ix Allowable%Drop: 17.9% Wire Res.Per Ft 0.003070 @ 75°Celsius �..� w Wire Gauge: 14ga Min.Device Voltage. 16.vdc N 0 c) o Starting Voltage: 19.5vdc %Voltage Drop 7.12% Z �- Ckt Capacity 2.A O Normal Operation Q Distance Device Voltage Voltage At �"� N (' Device# PID Setting Feet Current Drop Device 0 1:NAC4:V4.1 4906.9129 15cd 58 0.075 0.425 19.08 1:NAC4:V4-2 4906.9103 15cd 23 0.060 0.583 18.92 s 'I:NAC4:V4.3 4906-9129 110cd 32 0.285 0.791 18.71 E a 1:NAC4:V4.4 4906.9129 110cd 57 0.285 1.061 18.44 w 1:NAC4:V4-5 4906-9103 15cd 63 0.060 1.250 18.25 U- 1:NAC4:V4-6 4906-9130 30cd 16 0.132 1.292 18.21 3 1:NAC4:V4-7 4906-9129 15cd 34 0.075 1.354 18.15 1:NAC4:V4-8 1 4906-9129 175cd 26 0.221 1.389 18.11CID Totals: 309 Ft 1.193A ,r 0 EXISTING 4009 NAC4 PANEL DETAIL SCALEKT.S. ca 0 o Q N) W C1 Y S U C1 a ca w Q o M Cf N CD w DRAWN BY: L.CONEDERA f- CHECKED BY: M.GERRON CC ISSUE DATE: 6(4120 1JOB* PROJECT#: 448:618834101 JOHNSON CONTROLS O 2020 SYSTEM: FIRE ALARM SYSTEM SHEET: EXISTING 4009 NAC4 DETA[t AND CALCULATIONS NQ w s - Q FA-501 et X 4 M ©Johnson Controls 2020.All rights reserved.Reuse,copying,modification or alteration of the drawings and other information contained herein is strictly prohibited.