Loading...
Plans (2) FPS2020-00054 OFFICE COPY IPRIME ELECTRICAL SERVICES PO BOX 872395 Vancouver,WA 98687 (360)CR 5-3565 (36o) 86339-9989 fax KSID COMMUNITY HIGH SCHOOL CCB#2T7825 IN THE EVENT CONFLICTS ARE DISCOVERED BETWEEN THE ORIGINAL SIGNED AND SEALED DOCUMENTS PREPARED BY THE FIRE AUPGRADE ARCHITECTS RANSMIAND/OR THE[RC FAX, AP778, AND ANY COPY OF THE DOCUMENTS TRANSMITTED BY MAIL,FAH, ELECTRONICALLY OR OTHERWLSG THE Ot_IGINAL SIGNED AND SEALED DOCUMENTS SHALL GOVERN. i ©Copyright Prime Electrical 2020 This drawing contains information that is property of Prime Electrical Services,LLC.This drawing is received in confidence and its contents may not be disclosed without prioreoasent of Prime Electrical Services,LLC.This drawing shall not be used for competitive bid purposes. SHEET LIST TABLE PRIME JOB# PROJECT# NUMBER TITLE DATE: SITE_ _ADDRESS I_NSTALL_ER FO.1 — COVER SHEET REVISIONS 1922 SW DURHAM RD . PRIME ELECTRICAL SERVICES , LLC FO.2 — GENERAL INFO. F0.3 — CALCULATIONS TIGARD , OR 97224 PO BOX 872395 F1 .0 — SITE PLAN VANCOUVER, WA 98687 F2.0 — SCHOOLHOUSE BUILDING FIRE ALARM PLAN aECEIVED F3.0 — ANNEX BUILDING FIRE ALARM PLAN MAY 6 ZOZj i F4.0 — TYPICAL WIRING & ALARM FIELD DEVICES CIN OF TIGARD UILDING DIVISION PLEASE PROVIDE PROPERTY OWNER GENERAL CONTRACTOR CO RECO DNFPA72 RECORD OF COMPLETION AT FINAL INSPECTION TIGARD-TUALATIN SCHOOL DISTRICT INLINE COMMERCIAL CONSTRUCTION , INC . 6960 SW SAN D B U RG ST . PO BOX 5837 VALIDITY OF PERMIT THE TIGARD OR 97223 ALOHA OR 97006 DOCUMENTS ANDO HER 0 BASED ON CONSTRUCTION 0 7 DATA SHALL NOT PREVENT THE CODE OFFICIAL FROM r" REQUIRING THE CORRECTION U HT1 OF ERRORS. OSSC 105.4 w rci bio 0 N QO p NO PRIME ELECTRICAL OFFICE COPY SERVICES & 'DESIGN °pO�A� REV[�PED FOR GUDL' COMPLIAIVCB Q� Approved:/ OTC: ( ) ;m_4 Permit #: Fp��o-oc�c��SL U Address: Suite #: BY: Date: DRAWN-BY: DATE: P.O. BOX 872395 DRAWINGS PREPARED & DESIGNED BY: OP 4,1,2020 VANCOUVER, WA 98687 No Exception Taken DESIGNED-BY: DATE: OLEG PRIMACHENKO MFIA, Inc OP 4/1/2020 PHONE: (360) 335-3565 Gary Adovnik Thursday, April 23, 2020 DRAWING FAX: (360) 869-9989 PHONE: (503) 318-5170 Checking is only for general conformance with the design concept of the project and EMAIL: oleg.p@primeelectricalco.com general compliance with the information Cover given in the contract documents. Any action # 6270S shown is subject to the requirements of the plans and specifications. Contractor is responsible for: Dimensions, which shall be SHEET confirmed and correlated at the job site; fabrication processes and techniques of construction; coordination of his work with O . that of all other trades; and the satisfactory performance of his work. FILE: FA1 PLANS.DWG — COVER PAGE F0.1 BY: OP PLOT: 4/16/2020 8:58 PM PRIME GENERAL NOTES: ABBREVIATIONS LEGEND FIRE ALARM WIRE SCHEDULE ELECTRICAL SERVICES EOLR END OF LINE RESISTOR SYMBOL DESCRIPTION WIRE SIZE/TYPE 1 . ALL WIRE AND CONDUIT MUST BE INSTALLED IN ACCORDANCE WITH PLANS NAD SPECIFICATIONS. PO BOX 872395 EOL END OF LINE S SLC LOOP or INITIATION CIRCUIT 18/2 FPLR Vancouver,WA 98687 (360)335-3565 2. ALL WIRE AND CABLE MUST BE RATED FOR FIRE ALARM USE PER THE LATEST REVISIONS OF THE NATIONAL ELECTRICAL CODE FSD FIRE/SMOKE DAMPER N NOTIFICATION APPLIANCE CIRCUIT 14/2 FPLR (36o)869-9989 fax SECTION 760. THIS IS A POWER LIMITED FIRE ALARM SYSTEM, ALL CALBE MUST BE MARKED FPL, FPLR, OR FPLP. EARA REMOTE FIRE ALARM ANNUNCIATOR (N) NOTIFICATION APPLIANCE CIRCUIT 12/2 FPLR CCB#217825 IN THE EVENT CONFLICTS ARE DISCOVERED BETWE3. ALL CONDUCTORS MUST TEST FREE OF GROUND BEFORE MAKING CONNECTION TO THE FIRE ALARM CONTROL PANEL. CD CANDELLA A AUDIO NOTIFICATION CIRCUIT 18/2 FPLR SEALED DOCUMENTN THE S PREPNAL ARED GNED H SEALED DOCUMENTS PREPARED BYTHE ARCHnECTS AND/OR THEIR CONSULTANTS, SD SMOKE DAMPER (A) AUDIO NOTIFICATION CIRCUIT 16/2 FPLR AN TANY RANSMITTED THEDOC FAY 4. THE LIFE SAFETY SYSTEM IS A COMPLETELY SUPERVISED SYSTEM. TRONSALLY ORYMAILFA$ ELECTRONICALLY OR OTHERWISE,THE DH DOOR HOLDER F SBUS CIRCUIT 16/4 FPLR ORIGINAL SIGNEDSHALL G VERN. DOCUMENTS sxatt GOVERN. 5. PUBLIC MODE LIFE SAFETY AUDIBLE TONES SHALL BE AUDIBLE THROUGHOUT THE SPACE AND SHALL HAVE A SOUND PRESSURE RTB REMOTE TEST BUTTON PL PLANUM RATING DESIGNATION _-- FPLP LEVEL NOT LESS THAN 15db ABOVE AMBIENT NOISE LEVEL MEASURED @ 10' FROM THE DEVICE & 5' ABOVE FINISHED FLOOR. WP WEATHERPROOF ALL WIRING AND INSTALLATION METHODS SHALL BE IN COMPLIANCE ©Copyright Prime Electrical 2020 WITH CURRENT RELEVENT NATIONAL ELECTRICAL CODE ARTICLES This drawing contains information that is n H is WG WIREGUARD AND RELATED SECTION CODE REQUIREMENTS. pyraawmgisoperty fPnme downed Services,I.I.C.nten 6. SYSTEM SHALL BE CLASS B CONFIGURATION. wmg isdisclsed wi confidenceand of may not be disclosed without prior consent of (D) EXISTING TO BE DEMOLISHED WIRING INSTALLATION NOTES: Prime Electrical Services,LbC.This drawing • LABEL ALL NETWORK, ANNUNCIATOR AND 1/0 CONTROL CIRCUIT shall nm he used for competitive hid pnrpoees. 7. INSTALL ALL PULL STATIONS AND AUDIOVISUAL UNITS AT SPECIFIED HEIGHTS PER NFPA 72 AND ADA REQUIRMENT. SEE MOUNING (E) EXISTING TO REMAINWIRING WITH CIRCUIT NUMBER TAG AND DESCRIPTION. HEIGHTS DETAIL ON DETAIL SHEET. • LABEL ALL SIGNAL CIRCUIT WIRES WITH SIGNAL CIRCUIT (RLC) EXISTING TO BE RELOCATED NUMBER TAG AND DESCRIPTION. PRIME JOB# • LABEL ALL ZONE WIRES WITH ZONE NUMBER TAG AND PROJECT# 8. SMOKE DETECTOR LOCATIONS ARE FOR REFERENCE ONLY AND SHALL BE INSTALLED PER NFPA 72. (RP) EXISTING TO BE REPLACED DESCRIPTION. DATE: 9. SMOKE DETECTORS ON CEILING MUST BE NO MORE THAN 15' FROM A WALL AND/OR NO MORE THAN 30' FROM EACH OTHER EXCEPT (N) NEW REVISIONS IN NARROW CORRIDORS OR IRREGULAR SPACES. (NIC) NOT IN CONTRACT 10. ALL FIRE ALARM DEVICES SHALL BE RIGIDLY AND SECURELY FASTENED TO WALLS OR CEILINGS. (N/A) NOT APPLICABLE 11 . NO SMOKE DETECTOR OR HEAT DETECTOR SHALL BE LOCATED CLOSER THAN 36" TO ANY AIR REGISTER, DIFFUSER, FLUORESCENT LIGHT OR CEILING FAN BLADE. FIRE ALARM SYMBOLS LEGEND 12. NO HEAT DETECTOR SHALL BE LOCATED CLOSER THAN 36" TO ANY PART OF ANY HEAT GENERATING DEVICE (FUSES, BOILERS, SYM DESCRIPTION MODEL# BACK Box WATER HEATERS, ETC.) FRTUPI FIRE ALARM CONTROL PANEL SK-5820XL-EVS NAC NAC EXPANSION PANEL SK-5496 ----- 13. HEAT DETECTORS ACCOMPANYING ELEVATOR SPRINKLER HEADS SHALL BE MOUNTED WITHIN 24" OF ASSOCIATED HEAD. ONE BATT FACP BATTERY CABINET DETECTOR PER HEAD. FAA 7N REMOTE ANNUNCIATOR PANEL SK-5860R ----- 14. INITIATING AND SIGNALING CIRCUITS ARE SEPARATE, CAN BE RUN IN SAME CONDUIT/RACEWAY/RISER IF ALLOWED BY NEC. VM-PA AMPLIFIER PANEL EVS-50W ----- 15. ALL CONDUCTORS SHALL BE LABELED BY CIRCUIT/ZONE AND ALL COLOR CODES SHALL MATCH. FD_1A Lj DILER COMMUNICATOR TG7LAF02 ----- © SPRINKLER FLOW SWITCH ----- ----- 16. ALL WORK SHOWN SHALL COMPLY WITH ALL NATIONAL, STATE AND LOCAL CODES, ORDINANCES, ETC. C) © SPRINKLER TAMPER SWITCH ----- ----- 0 17. PER NFPA 72 17.7.1 .11 .3, ALL SMOKE & HEAT DETECTOR HEADS NOT REQUIRED FOR CONSTRUCTION SHALL BE INSTALLED AFTER ❑M ADDR. MONITOR MODULE SK-MONITOR 4X4 STANDARD ELEC.BOX ALL OTHER TRADES HAVE COMPLETED THEIR CLEANUP PROTOCOLS. WHERE DETECTORS ARE ALREADY INSTALLED, THEY SHALL ❑F ADDR. MANUAL PULL STATION SK-PULL-DA 1 -GANG STANDARD ELEC.BOX w BE PROTECTED FROM DUST, DIRT & DEBRIS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. (--•i ® ADDRESSABLE RELAY SK-RELAY 4X4 STANDARD ELEC.BOX rzi 18. PROVIDE FIRE ALARM SYSTEM EQUIPMENT AND SERVICE LABELS PER AHJ REQUIREMENTS. THE LOCATION OF ALL FA PANELS 1s ISOLATION MODULE SK—Iso 4X4 STANDARD ELEC.BOX TO BE PERMANENTLY NOTED AT THE PANELS. THE LOCATION OF THE POWER SOURCE CIRCUIT BREAKER PERMANENTLY LABELED © ADDRESSABLE CONTROL MODULE SK-CONTROL 4X4 3.5" DEEP ELEC.BOX x N AT ALL FA PANELS. CV 02 DUCT SMOKE DETECTOR SK-DUCT 4x4 STANDARD ELEC.BOX a 19. PRE-TEST THE SYSTEM TO VERIFY PROPER PERFORMANCE PRIOR TO INSPECTION. PHOTO SMOKE SENSOR W/BASE SK-PHOTO 4" OCTAGON ELEC.BOX ON 20. LABEL ALL ADDRESSABLE FIELD DEVICES SUCH THAT ADDRESS INFORMATION CAN BE READ FROM FLOOR LEVEL WITHOUT NEED QH HEAT DETECTOR W/BASE SK-HEAT 4" OCTAGON ELEC.BOX O FOR LADDER - OTHER BOXES AND DEVICES LABELED ANDREADILY LEGIBLE ALSO. A CEILING SPEAKER/STROBE UNIT SPSCWL 4x4 3.5" DEEP ELEC.BOX Q F CEILING HORN/STROBE UNIT PC2WL 4" OCTAGON ELEC.BOX F CEILING STROBE UNIT SCWL 4" OCTAGON ELEC.BOX O b4 cl r_4 WALL SPEAKER/STROBE UNIT SPSR 4x4 3.5" DEEP ELEC.BOX U Cq E-1 CEILING F F F WALL HORN/STROBE UNIT P2R 1-GANG STANDARD ELEC.BOX Z6"MIN 6"MIN WALL STROBE UNIT SR 1-GANG STANDARD ELEC.BOX • � 30' MAXIMUM HEIGHT SPRINKLER FIRE ALARM BELL ----- 1-GANG STANDARD ELEC.BOX � 'S4F�+1 F F F ❑J JUNCTION BOX ----- 4x4 STANDARD ELEC.BOX Q� V 96"6X 96"MAX FARA FACP OR EXTENDER 80 MIN 80"MIN PANELF❑ 60" BOTTOM BOTTOM APPROX. 72 r OF LENS OF LENS DRAWN-BY: DATE: OP 4/1/2020 48"MAX DESIGNED-BY: DATE: 42"MIN OP 4/1/2020 DRAWING FINISHED FLOOR Info. a TYP. FIRE ALARM DEVICE MOUNTING SHEET X0,2 SCALE: NONE Fo . 2 FILE: FA1 PLANS.DWG — FA FO.2 BY: OP PLOT: 4/16/2020 8:58 PM IntelliKnight 5820XL-EVS Battery Calculation PRIME Audio Notification Appliance Circuit Calculation Form ELECTRICAL Secondary Power Source Requirements SecondaryStandby Current(amps) SERVICES Project Name: Creekside High School Resistance Table Device Type Qty Current Draw___FQty I Current Draw Total Project Number: PO 20-169 Wire Type AWG Ohm/pair/1 Ohm/wire/1 1.Control Panel PO BOX 872395 Panel Type: EVS-50W k ft. k ft. FACP 1 1 IxI 0.320000 1=1 0.320000 1 1 IxI 0.440000 1=1 0.440000 Vancouver,WA 98687 Panel Location: Basement #10 Solid 2.42 1.21 2.Addressable SLC Devices (360)335-3565 Comment: #10 Stranded 2.48 1.24 SK-PHOTO 31 x 0.000300 = 0.009300 31 x 0.000300 = 0.009300 (36o)869-9989 fax #12 Solid 3.86 1.93 SK-HEAT 6 x 0.000300 = 0.001800 6 x 0.000300 = 0.001800 #12 Stranded 3.96 1.98 SK-MONITOR 2 x 0.000375 = 0.000750 2 x 0.000375 = 0.000750 CCB#217925 System Voltage Vac : 70 vans #14 Solid 6.14 3.07 SK-MINIMON 1 x 0.000375 = 0.000375 1 x 0.000375 = 0.000375 Y 9 ( ) IN THE EVENT CONFLICTS ARE DISCOVERED Amplifier Watts: 50 w #14 Stranded 6.28 3.14 SK-PULL-DA 13 x 0.000375 = 0.004875 13 x 0.000375 = 0.004875 BETWEEN THE ORIGINAL SIGNED AND Maximum dB loss: 1.00 #16 Solid 9.78 4,89 SK-MONITOR-2 1 x 0.000750 = 0.000750 1 x 0.000750 = 0.000750 SEALED DOCUMENTS PREPAREDBYTHE SK-RELAY 4 x 0.000255 = 0.001020 4 x 0.000255 = 0.001020 ARCHI'I'EC'1SAND/OR THEIR CONSULTANTS, Circuit Spare Capacity 9 70% #16 Stranded 9.98 4.99 AND ANY COPY OF THE DOCUMENTS Derating Factor 1.2 #18 Solid 15.54 7.77 4.SLC Isolator Devices TRANSMrrfED BY MAIL,FAX, 9 SK-ISO 1 2 IxI 0.000450 = 0.000900 2 x 0.000450 = 0.000900 ELECTRONICALLY OR OTHERWISE,THE ORIGINAL SIGNED AND SEALED DOCUMENTS #18 Stranded 15.9 7.95 6.Accessory Modules SHALL GOVERN. 5860R 1 2 IxI 0.020000 1=1 0.040000 2 IxI 0.025000 1=1 0.050000 5496 1 2 JxJ 0.010000 1=1 0.020000 1 2 IxI 0.010000 1=1 0.020000 Maximum Circuit Calc. Wire Type Length Feet Speaker Volts @ Watts @ Actual dB Spare 7.Voice Amplifiers and Accessories Circuit# Circuit ID: atts (Watts) (Watts) AWG (One Circuit Ohm Ohm. End End Loss Watts Comments p (W ) (W ) (W ) ( Y) EVS-50W 2 x 0.010000 = 0.020000 2 x 0.010000 = 0.020000 ©Copyright Prime Electrical 2020 1 AMP2-01 16.6 4.5 5.4 #18 Solid 235 3.652 907.41 69.719 5.357 -0.035 db 12.1 w 9.Output Circuits This drain$Cpntains information that is 2 AMP2-02 16.6 5.5 6.6 #18 Solid 285 4.429 742.42 69.585 6.522 -0.052 db 11.1 w NAC 1 0.000000 = 0.000000 = propertyofPrime Eleconfi ence an LLC.This drawing u received m confidence and its mments 3 AMP2-03 16.6 5 6 #18 Solid 423 6.573 816.67 69.441 5.905 -0.070 db 11.6 w NAC 2 0.000000 = 0.000000 = may not he disclosed without prior conemtof PriElecRicalServices, .LLCThis drawing 4 #18 Solid me NAC 3 0.000000 = 0.000000 = shall notbeuxd forcorn ' ebidpurposes 5 #18 Solid NAC 4 0.000000 = 0.000000 = 6 #18 Solid NAC 5 0.000000 = 0.000000 = Total: 15 18 NAC 6 0.000000 = 0.000000 = ' Note: All Resistance values are taken from Table 8 PRIME JOB# Conductor Properties of the NFPA70 National Total Standby Load 0.419770 Total Alarm Load 0.549770 PROJECT# Electrical Code.All values are for Direct Current DATE: Resistance at 75'C(167°F). IntelliKni ht 6820-EVS Battery Calculation REVI9;tONS SK-SENSORS EVS-50W BatteryCalculation Calculation in Total Sheet //J LOOP ADD# TYPE Part.# DESCRIPTION/LOCATION Secondary Power Source Requirements ' v 24 Hours 1 1Standby Current(amps) Secondary Alarm Current(amps) Standby Load Current 0.41977 Amps x 24 = 10.074 AH 16Z'70 S 1 SENSORS EXISTING DEVICES @ BLDG. CCHS p • - • . Qty Current Draw Julfiflin � 1 20 EVS-50W (25V) X 0.0850 = X 0.5250 = 15 Minutes EVS-50W (70.7V) 1 X 0.1000 = 0.1000 1 X 0.5800 = 0.5800 Alarm Load Current(Amps) 0.54977 Amps x 0.25 = 0.137 AH = 1 21 Photo Smoke SK-PHOTO SH Bsmt. Staff room 5-07 EVS-CE4 X 0.0200 X 0.1800 Total Current Load 10.212 AH Number of Watts @ 25 Vrms X 0.0000 = X 0.0400 = Multiply by the Derating Factor 1.2 = x 1.20 1 22 Photo Smoke SK-PHOTO SH Bsmt. Hall S-Ol Number of Watts @ 70.7 Vrms 15 XI 0.0000 = 0.0000 15 X 0.0450 = 0.6750 1 23 Photo Smoke SK-PHOTO SH Bsmt. Classroom S-08 Total Ampere Hours Required 12.25 AH 1 24 Photo Smoke SK-PHOTO SH Bsmt.Classroom S-08 Total Standby Load 0.1000 Total Alarm Load 1.2550 1 25 Photo Smoke SK-PHOTO SH Bsmt.Classroom S-09 Recommended Batteries: 6914 - 18AH Batteries 1 26 Photo Smoke SK-PHOTO SH Bsmt. Boys Restroom S-02 '1 27 Photo Smoke SK-PHOTO SH Bsmt. Girls Restroom 5-03 ours1 28 Photo Smoke SK-PHOTO SH Bsmt. Storage S-04 Standby Load Current (Amps) 0.1000 Amps ;;24 = 2.400 AHProject Name: Creekside High School Standby Hours: 24 1 29 Heat Detector SK-HEAT SH Bsmt. Mechanical 5-06WOUM4 Einutes ProjectlD: Alarm Mins:1 30 Photo Smoke SK-PHOTO SH Bsmt.Custodial S-OS Alarm Load Current(Amps) 1.2550 Amps = 0.314 AH Prepared By: Oleg Pnmachenko Derating Factor: 2 1 31 Photo Smoke SK-PHOTO SH 1st. Office 5-103 1 32 Photo Smoke SK-PHOTO SH 1st. Classroom 5-104 Total Current Load 2.71 AH Date: Voltage Drop Warning 411/2020 'Multiply by the Derating Factor 1.2 = x 1.20 Threshold°!° : 1 33 Photo Smoke SK-PHOTO SHlst. Stair S-105 O 1 34 Photo Smoke SK-PHOTO SH 1st. Classroom S-106 Total Ampere Hours Required 3.26 AH 1 35 Photo Smoke SK-PHOTO SH 1st. Library S-100 Panel ID: NPS-02 Model: SK-5496 Power Expander Max NAC Current: 3.0 Amps O 1 36 Photo Smoke SK-PHOTO SH 1st. Library S-100 Location: Basement Volts: 24 VDC Max Panel Current: 10 Amps 1 37 Photo Smoke SK-PHOTO SN 1st. Office 5-102 Recommended Batteries: BAT-1270 -7AH Batteries Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ oDrop U rTl 1 38 Photo Smoke SK-PHOTO SH 1st. Office S-101 Ckt.# Circuit Name TV�11 fid 1 39 EVS-50W Circuit Detail Standby Alarm & Type 1000 Ft. One-Way Ohms EOL /o 5496 SK-5496 Pwr Module 1 1 0.01 0.01 ( 1 1 40 Speaker# 1 NAC#1 NPS2-01 cfg. 0.000 0.531 =14 S,o 11 a 2.52 235 1.18 19.77 3.08% 111���J111 1 41 Photo Smoke SK-PHOTO Annex Classroom A-101 Device Qty Watt Tap Watts NAC#2 NPS2-02 cfg. 0.000 0.562 ; =13 solid - 2.52 1 285 t44 19.59 3.96% 1 42 Photo Smoke SK-PHOTO Annex Classroom A-101 @ 1 Watt Tap 3 x 1.000 = 3.000 NAC#3 NPS2-03 cfg 0.000 1.055 r_12 Soiic - 1.59 423 1.35 18.98 6.96°6, • r"1 F�.L/.( 1 43 Heat Detector SK-HEAT Annex Mechanical A-105 @ 1/2 Watt Tap 3 x 0.500 = 1.500 x 0.000 NAC#4 spare cfg. 0.000 0.000 s14 solid I�_ 2.52 0.00 20.40 0.00% 1 44 Photo Smoke SK-PHOTO Annex Classroom A-102 x 0.000 - Aux rig 0.000 0.000 r.14 solid 2.52 0.00 20.40 0.00% ANNUNCIATION NOTIFICATION FIRE SAFETY CONTROL ^ �--1 N 1 45 Photo Smoke SK-PHOTO Annex Classroom A-102 Total Quantity: 6 Total Watts: 4.500 Total Standby Current (Amps) 0.010 2.158 Total Alarm Current (Amps) 1� i•� N 1 46 Photo Smoke SK-PHOTO Annex Classroom A-103 Standby Time In Hours 24 0.250 Alarm Time In Minutes 160 (15 Mins) �O� ..� (� l� 1 47 Photo Smoke SK-PHOTO Annex Classroom A-103 Speaker#2 Total Standby AH Required 0.240 0.540 Total Alarm AH Required \VF O� • t� rs--1 1 48 Heat Detector SK-HEAT Annex Mechanical A-106 '' • Total Combined AH Required 0.78 1 49 Photo Smoke SK-PHOTO Annex Classroom A-104 - O @ 1/2 Watt Tap 3 x 0.500 1.500 @ 1 Watt Tap 4 x 1.000 = 4.000 Multiply By The Derating Factor 1.20 1 50 Photo Smoke SK-PHOTO Annex Classroom A-104 Minimum Battery AmpHours Required 0.94 O O O� 2� O� QV x 0.000 = 2 C1 2 Q 1 51 Heat Detector SK-HEAT Annex Mechanical A-002 x 0.000 = �� V 1 52 Photo Smoke SK-PHOTO Annex Classroom A-001 Total Quantity: 7 Total Watts: 5.500 GO O�P�Q O� L') Gj � v ��v0 S ;�-I 1 53 Photo Smoke SK-PHOTO Annex Classroom A-001 qY ,� �O VP ��O \O== V� �V cn (IS Speaker#3Gj 0V O Q �O V � �� � J JO .� VJ J� � �es � �`� 0N bA .. • QJ 3 �JQ Q �o o ,��, �• v J �� v •Lr, @ 1 Watt Tap 5 x 1.000 = 5.000 J� F Q �J ���Q �, �� G�QV`O V �) N L� SK-MODULES x 0.000 = O O= LOOP ADD# TYPE Part.# DESCRIPTION/LOCATION x 0.000 = 4i, 1 1 x 0.000 = "CA.7 _Z) 1 1 MODULES EXISTING DEVICES @BLDG.CCHS Total Quantity: 5 Total Watts: 5.000 C9 F F F F F F F Q Q Q 0 F I 1 20 Speaker#4 Device Qty Watt Tap WattsQ Q P Q Q P Q Q Q Q QsGIJ �� �P Q 1 21 Pull Station SK-PULLSA SH Bsmt. Hall S-01 IXI 0.000 1=1 SYSTEM INPUTS & ACTIONS A B C D E F G H I J K L M N O P Q R S T U V W X Y Z AA AB �1� 1 22 Pull Station SK-PULLSA SH Bsmt. Classroom S-08 x 0.000 = 1 SMOKE SENSOR DETECTOR x x x x x x x x 1 W 1 23 Pull Station SK-PULLSA SH Bsmt. Storage S-04 x 0.000 = 2 HEAT SENSOR DETECTOR x x x I x x x x x I I 1 2 �--1 1 24 Pull Station SK-PULLSA SH 1st. Library S-100 North Total Quantity: Total Watts: 0.000 3 FIRE PULL STATIONS x x x x x x x x 3 1 25 Pull Station SK-PULLSA SH 1st. Library S-100 East 4 4 1 26 Pull Station SK-PULLSA SH 1st.Stair S-105 5 5 1 27 Monitor SK-MONITOR SH Bsmt. Water Flow 6 1 1 1 6 1 28 7 1 FACP, NAC, AMP, DIALER PANELS AC POWER FAILURE x I x I I I Ix I 1 7 1 29 8 FACP, NAC, AMP, DIALER PANELS LOW BATTERY x x x 8 1 30 9 OPEN CIRCUIT x x x 9 DRAWN-BY: DATE: 1 31 Pull Station SK-PULLSA Annex Classroom A-101 10 GROUND FAULT x x x 10 OP 4/1/2020 1 32 Pull Station SK-PULLSA Annex Classroom A-102 11 11 12 LIVE VOICE MICTOPHONE x x x 12 DESIGNED-BY: DATE: 1 33 Pull Station SK-PULLSA Annex Classroom A-103 13 1 13 OP 4/1/2020 1 34 Pull Station SK-PULLSA Annex Classroom A-104 141 1 1 1 1 1 1 14 1 35 Pull Station SK-PULLSA Annex Classroom A-001 15 WATERFLOW SENSOR x x x x 15 DRAWING 16 16 17 8 18 Calculations 19 19 20 1 120 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z AA AB SHEET A SEQUENCE OF OPERATION MATRIX Fo . 3 SCALE: NONE FILE: FA1 PLANS.DWG - FA F0.3 BY: OP 1 PLOT: 4/16/2020 8:59 PM PRIME 75 AP2-04 KELECTRICAL A NPS2-04 4.71K H 2 2 F SERVICES 1 w S:051 S:052 S:053 M:035 PO BOX 872395 Vancouver,WA 98687 (360)335-3565 (N),A ANNEX BUILDING LOWER FLOOR (36o)869-9989 fax CCB#217825 ANNEX BUILDING 1ST FLOOR IN THE EVENT CONFLICTS ARE DISCOVERED BETWEEN THE ORIGINAL SIGNED AND SEALED DOCUMENTS PREPARED HYTHE 75 15 15 15 15 75 ARCHITECTS AND/OR THEIR CONSULTANTS, AND ANY COPY OF THE DOCUMENTS S TRANSMITTED BY MAH.,FA%, c c C ELECTRONICALLY OR OTHERWISE,THE F -------- F -------- F -------- A ORIGINAL SIGNED ALL GO EALEDDOO bffi IS 1ERN w 1w ©Copyright Prime Electrical 2o2o This drawing contains information that is property of Prime Electrical Services,LLC.This drawing is received in confidence and its contents my not be r consent (N),A 75 75 15 15 15 15 75 Prime Elec[ricaldisclosed without LLC.Tins drawtingf F 2 2 H 2 F 2 F 2 2 H 2 F 2 shall not be used for competitive bid purposes. F - AF - F ------- F -------- F A NPS2-03 M:031 S:041 S:042 S:043 S:044 M:032 S:045 M:033 S:046 S:047 S:048 S:049 M:034 S:050 1 w ; 1 w PRIME JOB# PROJECT# AMP2-03 DATE: - REVIS NS ANNEX BUILDING 1ST FLOOR SCHOOLHOUSE 1ST FLOOR L7 A—� (N) S 75 75 15 15 15 30 75 15 NPS2-02 NPS2-02 2 2 2 F 2 2 2 2 2 F F 4.7KA A A A A A A F S:031 S:032 S:033 M:026 S:034 S:035 S:036 S:037 S:038 M:024 M:025 1w 1w 1/2w 1/2w 1/2w 1w i 1w AMP2-02AMP2-02 15K — (N)AAN SK-5860R A---cam i SCHOOLHOUSE 1ST FLOOR SCHOOLHOUSE BUILDING BASEMENT 15 15 75 15 15 15 30 75 15 O NP S2-01 4.7K F F A ----- A A A A A F S U 1 w 1/2w 1/2w 1/2w 1 w i 1 w w AMP2-01 --------------------AMP2-01 Q 15K �--1 ; Iy1 N S:021 S:023 S:024 S:025 M:022 S:022 M:021 S:026 S:027 S:028 M:023 S:029 S:030 M:027 ct • r--1 (N) (N) AMPLIFIER NAC POWER C) EVS-50W SUPPLY Q AMP2 SK-5496 S NPS2 bio �S V N F-+ ONF (N)120VAC ---------------------- ----------- --------------------------- -------------------------------------------; A SCHOOLHOUSE BUILDING BASEMENT ►, F S A—d CCHS MAIN BUILDING V I (E) (E) (E) DRAWN-BY: DATE: SK5820XL-EVS NAC POWER AMPLIFIER OP 4/1/2020 FACP SUPPLY EVS-50W DESIGNED-BY: DATE: SK-5496 AMP1 OP 4/1/2020 NPS1 (E)FA CELL DRAWING COMMUNICATOR Riser a Fire Alarm System Riser Diagram SCALE: none �(� , 4 (E)120VAC SHEET Fo * 4 FILE: FA1 PLANS.DWG — FA FO.4 I BY: OP PLOT: 4/16/2020 8:59 PM PRIME � .. LA - i' ELECTRICAL -- �Ja SERVICESo y PO BOX 872395 Vancouver,WA 98687 C _ — i (360)335-3565 (360)869-9989 fax r r_ '-1 ��—% CCB#217825 t }�' -.�� - J �C] IN THE EVENT CONFLICTS ARE DISCOVERED BET WEEN THE ORIGINAL SIGNED AND 4 TSS'-� - L U S C H O O L H O V E �- SEALED DOCUMENTS PREPARED BYTHE i ARCHITECTS AND/OR THEIR CONSULTANTS, ''7 1 _4 .~ ANDANY RANSMI TEDOF THEDOC MENTS FAY, SJ TRANSMITTED BY MAIL,FAX, ELECTRONICALLY OR OTHERWISE,THE U I L D I N G - �1 8 ORIGINAL SIGNED AND SEALED DOCUMENTS SHALL GOVERN. a o — s ©Copyright Prime Electrical zozo --- — __Fl This Brewin contains information that is property of Prime Electrical Services,W.This r BREEZEWAY I drawing,=received; nEenooan�its�o '� _ t be disc) withoutt Prime Electrical Services,LLC.Thu draxnng( ,t L� f ! 3l sh all not be used(or comPeBwebid purposes.` !� I w uy ! = O 3 �F F PRIME JOB# t PROJECT# I :✓ / I DATE: s DECK — ... _ REVISIONS ° - I � i? _ K , j 8 3 -:- -. a a , i _ y V fi I it U I'�}� ai CCHS MAIN � o BUILDING O Wit ; ANNEX _ w to BUILDING ;E ON COVERED PLAY ti I U N -- — ..- O t r DRAWN-BY: DA / OP 1/2020 DESIGNED—BY: DATE: OP 4/1/2020 DRAWING A Site Plan Site Plan Is Q SCALE: 3/32" =1 '—O" SHEET Fl ,, o FILE: FA1 PLANS.DWG — FA F1 .0 BY: OP PLOT: 4/16/2020 9:00 PM PRIME ELECTRICAL SERVICES PO BOX 872395 Vancouver,WA 98687 (36o)335-3565 (36o)869-9989 fax CCB#217825 IN THE EVENT CONFLICTS ARE DISCOVERED ., BETWEEN THE ORIGINAL SIGNED AND SEALED DOCUMENTS PREPARED BYTHE ARCHITECTS AND/OR THEIR CONSULTANTS, AND ANY COPY OF THE DOCUMENTS TRANSMITTED BY MAIL,FAX, ELECTRONICALLY OR OTHERWISE,THE ORIGINAL SIGNED AND SEALED DOCUMENTS SHALL GOVERN. i g TO BASEMENT "thE TO IST FLOOR " DN PULL STATION * ©Copyright Prime Electrical 2020 i I PULL STATION .�, This drawing contains infomtation that is li -41 !UP property of Prime Electrical Services,LLC.This drawing is received in confidence and its contents % I may not be disclosed without prior coment of S S Prime Electrical Services,LLC.This drawing shag not he used for competitive bid purposes FM:024 NPS2 -02 i GIRLS FM:023 NPS2-02 4.7K PRI5-003 NPS2-01 CUSTODIAL P OIJECP# # A P2-02 A 16KP2-02 A P2-01 --- — DATE: A S-005 NPS2-01 S 4.7K REVISIONS OFFICE 25:038 25:027 STORAGE S - - FIRE RISER S-101 S-004 1504 F 5:30 / CLASSROOM PS2-01 �� C/ S-106 75cd N,A,S N,A,S NPS2-01 M t� 70 Cj S:034 S:035 1w N,S M:027' C� 2 N,A,S 2 N,A,S AMP2-01 A MP2-01 (E, ) A AN,A,s 2 L6' 30cd 30cd PS2-02 S:028 WP NPS2-02 NPS2-02 1/2W 1W 1W AMP2-02 AMP2-02 AMP2-02 A NS 2 S:037 BOYS 15cd 15cd F H N,A,S OFFICE S-002 NPS2-01 PS2-01 s:ozs AMP2-01 MECH S-102 A S-006 2 2N,2A,S S:026 LIBRARY S-100 N,A,S J HR TO BASEMENT HR TO PANELS O TO 1ST FLOOR NPS2-02,03&AMP2-02,03 J CODE REQUIRES MIN 12" CLEAR � NPS2-03&AMP2-03 (N),N,2A,S AT LATCH SIDE OF DOOR. 2N 2A g (N),A 15cd0 NPS2-01 (N),2N,2A,S-- 2 ALSO, ENSURE PANEL DOES STORAGE N,A,S AMP2-01 N,A,S N,A,S N,A,S S:033 z NOT STICK OUT FROM WALL - --- F A 1 J F 2 TELECOM PANEL HR TO ANNEX S —� MORE THAN 4 S-011 M:021 15cd 1�1 BUILDING S-036 STAFF NPS2-01 S:021 J HR TO NPS2 PANEL NPS2-03& Y M�026 930cd = IF 12" CLEAR CANNOT BE 2 — NPS2 F ' J F .— M:025 Z IN THE BASEMENT MAINTAINED, CONSIDER S:022 S-007 IS MP J -- —+r HR TO CCHS MAIN AMP2-03 (N)As 15cd S,F S BUILDING FACT PANEL h/^� (N),A,S NPS2-02 RELOCATING TO NORTH SIDE F,S,A PROVIDE RACEWAY BETWEEN NPS2-02 OF DOOR, HALL 2N 2A S SF • SCHOOLHOUSE AND ANNEX AMP2-02 IT $-QQ1 r �j N BUILDING FOR FIRE ALARM WIRES ^ v 5-010 CV TO 1 ST FLOOR ^+•) 2N,2A,S PULL STATION • .J CLASSROOM 2 :1�) i"'' P4 5-104 s:023 Q O 30Cd 2N,2A,S CLASSROOM . NPS2-01 ---------- ----- NPS2-02 1/2W 2N,2A,S S-008 1w A AMP2-01 AMP2-02 rSO25 S:032 NPS2-012N •�1 W V AMP2-01 CN N S2-02 S 1/2w OFFICE • t..I I—I 2N,2A,S AMP2-02 S-009 2 2 � S:031 i � 5:024 4�. W OFFICE - S403 s i M:022 ?e� F fI DRAWN-BY: DATE: OP 4/3/2020 _ DESIGNED-BY: DATE: OP 4/3/2020 A 1ST FLOOR FIRE ALARM B BASEMENT FLOOR FIRE ALAS Schoolhouse F2 , 0 SCALE: 1/16" =1 '-0" X2 , 0 SCALE: 1/8' —0 ' - ' Building SHEET F2 * 0 FILE: FA1 PLANS.DWG — FA F2.0 I BY: OP I PLOT: 4/16/2020 9:00 PM PRIME ELECTRICAL SERVICES PO BOX 872395 Vancouver,WA 98687 PROVIDE RACEWAY BETWEEN SCHOOLHOUSE (360)335-3565 AND ANNEX BUILDING FOR FIRE ALARM WIRES 360)869-9989 fax CCB#217825 IN THE EVENT CONFLICTS ARE DISCOVERED BETWEEN THE ORIGINAL SIGNED AND SEALED DOCUMENTS PREPARED BY THE HR TO NPS2-03 8 AMP2-03 ARCHITECTS AND/OR THEIRCONSULTANTS, AT SCHOOLHOUSE BLDG. AND ANY COPY OF THE DOCUMENTS z TRANSMITTED BY MA14 FAR, ELECTRONICALLY OR OTHERWISE,THE 5.041 ORIGINAL SIGNED AND SPATE DOCUMENTS >--(N)A.S SHALL GOVERN. M:031 S F A NPS2-03 Iw AMP2-D3 CLASSROOM ©Copyright Prime Electrical 2020 This drawing contains information that is A-101 property of Prime Electrical Services,W.This MA,S drawing is received in confidence and its ountema may not be disclosed without prior consent of Prime Electrical Services,LLC.Ibis drawing 15cd 150d S shall not be used for competitive bid purposes. NPS 2 NPS2-03, F Q 5:042 PRIME JOB# PROJECT# (N)A.s DATE: MECH -'�H REVISIONS A-105 8:043 S F F 2 (� N NPSism 5:044 '. NPS NPS2-03 N)A.S CLASSROOM s A-102 E3 M:032 A 75W NPS2-03 1w AMP2-03 (N)A.S 2 COVERED 8:D45 WALKWAY �� f wP 75m F NPS2-03 O 2 O N)A,S 5046 — ` zi S C W *:033 A NPS 75od �1 1w AMP2-03 CLASSROOM (N)A.S A-103 • P'1 150d 15cd s N NPS2 NPS2-03 � /t� C F F 2 W CA 5:047 (N)A.S O METH METH s:o4B A-002 A-106 HRUPTO H (N)A.S 1STFLOOR 5:051 ca.� (N)AS bj S C Ir 4 F F V N OE--q 5cd NPS NPS NPS2-03 Z (N)A.S 5:052 • ^� (roAs la-aaaa1 r7aasz-03 CLASSROOM DOWN TO M'0 A AMP2-03 A-104 CLASSROOM n , GROUND A-001 (N)A.S moi/ LEVEL (N)A.S S 2 5:050 Z 5053 (N)A.S 75cd NPS203 s 1w M:035 AMP2-03 A AMP2-03 F. ISE STORAGE NPs2-03 DRAWN-BY: DATE: A-003 41K OP 4/1/2020 DESIGNED-BY: DATE: _ OP 4/1/2020 DRAWING Annex a 1ST FLOOR FIRE ALARM g LOWER FLOOR FIRE ALARM Building F3 . 0 SCALE: 1/8" =1 '-0" F3 . 0 SCALE: 1/8" =1 '-0" SHEET F390 FILE: FA1 PLANS.DWG — FA F3.0 I BY: OP I PLOT: 4/16/2020 9:00 PM PRIME ELECTRICAL SERVICES PO BOX 872395 Vancouver,WA 98687 TYPICAL 'T' TAP WIRING (360)335-3565 (360)869-9989 fax CCB#217825 5 8 2 0 X L IN THE EVENT CONFLICTS ARE DISCOVERED BETWED AND TYPICAL WIRING TO REMOTE ANNUNCIATOR SK-5860 RALE. DOCUMEEN THE NTS PREPARNAL ED '----------------------------------� sCHI.ECTS AND/OR THEIR LTNT ARCHITECT'S AND/OR TFIEDL CONSULTANTS, AND ANY COIR OF THE DOCUMENTS — — — — TRANSMITTED BY MAIL,FAX, tt rI@ ELECTRONICALLY OR OTHERWISE,THE SLC DEVICE Boa dn%\ssembl1 ORIG NAL SIGN�ANGOV RN. DOCUMENTS IN THIS EXAMPLE •------- = 1000 FEET POWNP90poppat zaze _ azzzlzo is a z s1 �o = 1600 FEET I 'o.c AFI N rbc? N ` - B - b t ©CoPYHBht Prime Electrical zozo RIM 3500 FEET IThis drawing coatamsinformation thatis property of prime Electrical Services,LLC.This Idrawing is received in confidence and its contents YOU CAN USE 18 AWG BECAUSE THE may not be disclosed without poor consent of I 8 ANNUNCIATORS MAX. PER SYSTEM Prime Electrical Services,ler.This dmving GREATEST DISTANCES IS 3500 FEET. shall not be used for competitive bid purposes. THE DEVICE LOCATED FARTHEST SLC DEVICE I ° FROM THE 5820XL MUST BE LESS I ° THEN THE MAXIMUM DISTANCE j PRIME JOB# PER WIRE GAUGE PROJECT'# Gauge Max. Distance SLC DEVICE REMOTE ANNUNCIATOR DATE: 22 AWG 1500 ft. (BACK VIEW) REVISIONS 18 AWG 3900 ft. + 16 AWG 6200 ft. 14 AWG 10,000 ft. DIPSWITCHES MAXIMUM LOOP RESISTANCE = 50 OHMS TYPICAL T TAP WIRING g WIRING TO REMOTE ANNUNCIATOR SK-586o . 0 SCALE: NONE Fq , 0 SCALE: NONE rl TYPICAL CLASS B AND CLASS A WIRING FOR DETECTORS U 5820XL J:5820XL Out SLC In t� SLC Out SLC In SC- S+ SC- S+ S SC S+ C. to g '6 - ® � � ® ® � N _ 11 + 3- 4 5- g 1. 13 a N DUT4 OUT OUT2 OU SBU ..� t Style 4 (Class B) H4- H4+ H3- H3+ H2 H8+ Hl- HI+ S- S+ B /T Style 6 (Class A) (+) 12 c+ c+> 12 c+ ^ (+) 6 5 (+) C+) 65 C+7 C+) (+> (+) C+) + HEAT OR SMOKE_ HEAT OR SMOKE DETECTOR BASE DETECTOR BASE O N •rI V NH � w (7% c WIRING SMOKE & HEAT DETECTORSNA POWER SUPLY WIRING � SCALE: NONE 0 SCALE: NONE �--i V DRAWN-BY: DATE: OP 4/1/2020 DESIGNED-BY: DATE: OP 4/1/2020 DRAWING Typical Wiring Field Devices SHEET F4 * 0 FILE: FA1 PLANS.DWG — FA F4.0 BY: OP PLOT: 4/16/2020 9:01 PM