Loading...
Plans (20) BUP2020 -00187 OFFICE COPY OFFICE COPY SITE EDWARD JONES SMMU REDIMKiND Architecture Interiors lfh4 t4iff4 j / Planning Engineering e TENANT IMPROVEMENT RECEIVED - uss su m AUG 12 2020 Portland, OR 4 LINCOLN : SUITE 215 Grr OF TIGARD 503.224.9560 /ff ff{I� BUILDING DIVISION Vancouver,WA PROJECT LEGEND 10250 SW GREENBURG RD , Seattle,WA60.695.7879 3 o an�rrem ase �_� F== EXISTING CONSTRUCTION TO BE DEMOLISHED 206.749.9993 TIGARD , OREGON O{HHHIIf4IIIHl � 1,: www.mcknze.com EXISTING WALL TO REMAIN m NEW WALL TO UNDERSIDE OF GRID, SEE 4/A5.20 MACKENZIE. STRUCTURED T", O �� � ® EXISTING DEMISING WALL FILE COPY - Client DFEIOM DRIVEN 1 CLIENT IOCOFC mth h+}I Hiitl�f � EXISTING 2-HOUR RATED WALL TO REMAIN CITY OF TIGARD,. SW Oak Streel -- - - REVIEWED FOR GLIDE COMPLIANCE o EXISTING 1-HOUR RATED WALL TO REMAIN v 25 100 200' Approved: �[J EXISTING QUADRUPLEX OUTLET OTC: I 1 VICINITY MAP Peentt#: Rtln9 nz S H O R E S T E I N �� EXISTING POWER AND DATA ft y,.�..rr J ��J �-70 ,0 NOT TO SCALE �S Address: EXISTING COVERPLATE INDEX OF DRAWINGS ssu" �tS — Date: CODE SUMMARY LEGEND q -R-10 EXISTING LIGHT SWITCH GENERAL I GO.01 TITLE SHEET, CODE SUMMARY, VICINITY MAP, KEY PLAN, LEGEND AND GENERAL NOTES EXT EXIT ACCESS OT EXISTING THERMOSTATProject ARCHITECTURAL EDWARD JONES ® ILLUMINATED EXIT SIGN ® EXISTING FIRE STROBE A1.10 DEMOLITION PLAN, PARTIAL SECOND FLOOR PLAN, COMBINED DEMOLITION AND REFLECTED CEILING SUITE 215 PROPOSED FIRE EXTINGUISHER LOCATION NEW OUTLET AND VOICE/DATA ROUGH IN LOCATION PLAN,ALTERNATE DEMOLITION REFLECTED CEILING PLAN, ALTERNATE REFLECTED CEILING PLAN, n FINISH SCHEDULE AND NOTES TENANT - AREA OF WORK NEW OCCUPANCY SENSOR LIGHT SWITCH A5.20 INTERIOR DETAILS AND ELEVATION IMPROVEMENT REMOVED LIGHT FIXTURES 4 LINCOLN m MINOR= R. m COMMON PATH OF EGRESS TRAVEL =67-2" (100'-0"MAX.) SCOPE O F WORK 10250 SW GREENBURG RD. EXISTING LIGHT FIXTURE TIGARD, OREGON THE SCOPE OF WORK FOR THE PROJECT INCLUDES INTERIOR TENANT IMPROVEMENTS OF ® Z EXISTING SUPPLY/RETURN VENT APPROXIMATELY 1,214 SQUARE FEET ON THE SECOND FLOOR OF THREE FLOORS TOTAL. WORK TO INCLUDE MINOR DEMOLITION, NEW WALLS, DOORS, RELITES AND FINISHES. S�R�_T+� o EXISTING SPRINKLER rr ''�� (( VALUATION: $24,000 J f ® NEW EXIT SIGN ~ P NG I EXISTING CEILING GRID DESIGN/CODE DATA t J� PORT ND, REG ® GOVERNING CODE: 2019 OREGON STRUCTURAL SPECIALTY CODE f' NEW BUILDING STANDARD LED LIGHT FIXTURE (ALT.) OCCUPANCY: B OF 01 CONSTRUCTION TYPE: TYPE 1-B TENANT AREA: APPROXIMATELY 1,214 SQUARE FEET 0 NEW SPOTLIGHT OCCUPANCY LOAD: 8 C MACKENZIE 2019 ALL RIGHTS RESERVED /� 1 REQUIRED EXIT, 1 EXIT PROVIDED. THESE DRAWINGS ARE THE PROPERTY OF 2 KEY PLAN ® CONFIRMED EE THROUGH DEFERRED SUBMITTAL TO BE BUILDING IS FULLY SPRINKLED AND HAS NFPA SMOKE DETECTION WITH ON SITE EMERGENCY MOR REPRODUCED N ANY MANNERACKENZIE AND ARE NOT TO BE ED 0.0 2ND FLOOR NTS GENERATOR FOR FIRE/LIFE/SAFETY BACKUP POWER. WITHOUT PRIOR WRITTEN PERMISSION REVISION SCHEDULE Delta Issued As Issue Date DEFERRED SUBMITTAL PROJECT GENERAL NOTES 2014 OSSC SECTION 107.3.4.2 (BY SEPARATE PERMIT) FIRE SPRINKLER A. THE DRAWINGS LOCATE PRODUCTS, SURFACES,AND MATERIALS AND THE NOTES CONVEY DESIGN INTENT. THE PROJECT INTENT IS TO PROVIDE FOR A COMPLETE, WORKING SYSTEM. FIRE ALARM MECHANICAL B. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO THE LATEST ADOPTED BUILDING CODE EDITION, AND TO CONDITIONS AND SPECIFICATIONS OF ALL GOVERNING AUTHORITIES. ELECTRICAL C. VERIFY AND CONFIRM ALL CONDITIONS, DIMENSIONS, AND LAYOUT INFORMATION PRIOR TO START OF CONSTRUCTION. NOTIFY MACKENZIE OF ANY DISCREPANCIES PRIOR TO START OF WORK. ANY CORRECTION WORK REQUIRED AS A RESULT OF NOT REPORTING SUCH DISCREPANCIES SHALL BE PERFORMED AT NO ADDITIONAL COST TO THE OWNER. D. CONTRACTOR AND SUBCONTRACTORS SHALL CAREFULLY EXAMINE THE SITE AND THE CONSTRUCTION DOCUMENTS OF THE ENTIRE WORK. INCONSISTENCIES IN THE PLANS OR SPECIFICATIONS SHALL BE SYMBOLS AND REFERENCES NOTE: DESIGN BUILDERS ARE FULLY RESPONSIBLE FOR THE DESIGN OF THESE SYSTEMS/COMPONENTS. CALLED TO THE ATTENTION OF MACKENZIE. PROJECT NORTH THESE SYSTEMS/COMPONENTS SHOWN ON DOCUMENTS ARE SCHEMATIC ONLY: THEY ARE NOT �— E. REFER TO ENLARGED PLANS AND ELEVATIONS WHERE INDICATED FOR ADDITIONAL INFORMATION. ENLARGED PLANS TAKE PRECEDENCE OVER PLANS OF SMALLER SCALE, AND DETAILS TAKE PRECEDENCE INTENDED TO REPRESENT FINAL/CODE COMPLIANT DESIGN. PROVIDE DESIGN DOCUMENT SUBMITTAL TO SHEET TITLE: OVER PLANS. IN THE CASE OF A CONFLICT, THE HIGHEST COST OPTION SHOULD BE PRICED. TRUE NORTH ARCHITECT OF RECORD FOR REVIEW PRIOR TO SUBMITTAL TITLE SHEET, CODE F. DETAIL REFERENCES SHALL BE APPLIED TO ALL INSTANCES WHERE THE SAME CONDITIONS OCCUR, UNLESS NOTED OTHERWISE. SUMMARY, VICINITY FILLED ARROW CONTACTS MAP, KEY PLAN, LEGEND G. THE TERMS "ABOVE FINISH FLOOR" (AFF) AND "FINISH FLOOR ELEVATION" (FFE) REFER TO FINAL FINISHED FLOOR ELEVATION, WHETHER BUILT-UP SLAB, COMPOSITE DECK, OR RAISED ACCESS FLOOR. A DETAIL# AND GENERAL NOTES H. DO NOT SCALE DRAWINGS. INTERIOR ELEVATION 12 ARCHITECT CONTRACTOR ;, SUB-CATEGORY MACKENZIE RUSSELL CONSTRUCTION I. CUTTING AND DRILLING OF STRUCTURAL MEMBERS NOT DETAILED REQUIRES THE WRITTEN PERMISSION OF THE STRUCTURAL ENGINEER OF RECORD. KEY MARK SHEET# J. SAVE AND RECYCLE DEMOLITION DEBRIS AS APPLICABLE. ALL DEMOLISHED OR REMOVED EXISTING MATERIAL SHALL BE LEGALLY DISPOSED. COORDINATE WITH CITY OF TIGARD REQUIREMENTS FOR CATEGORY 1515 SE WATER AVE, SUITE 100 20915 SW 105TH AVE RECYCLING/RE-USE OF DEMOLITION DEBRIS. PORTLAND, OR 97214 TUALATIN, OR 97062 K. THE CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE RESULTING FROM THEIR WORK. THE CONTRACTOR WILL COORDINATE CLEAN UP OF ALL AREAS AFFECTED BY DUST OR ANY MATERIALS, BOTH KEYNOTE CONTACT: CARPENTER CONTACT: DONN STURDIVANT DRAWN BY: SW 503.22 DURING CONSTRUCTION AND UPON COMPLETION OF THE PROJECT, INCLUDING THE INSIDE OF ALL WINDOWS AS NECESSARY SO THAT THE SPACE IS READY FOR OCCUPANCY BY TENANT. SPACE NAME TEL: 503.224..9560 TEL: 503.692.9002 L. ALL DESIGN-BUILD ITEMS, SYSTEMS, AND ELEMENTS ARE TO BE SUBMITTED FOR REVIEW AND APPROVED BY MACKENZIE. OFFIC SPACE # FAX: 503.228.1285 EMAIL: DSTURDIVANT@RUSSELLCONSTRUCTION.COM ROOM/SPACE IDENTIFICATION 11q EMAIL: LCARPENTER@mcknze.com CCB: 58918 CHECKED BY: MRT, PDK M. EXISTING MATERIAL NOTED TO BE RETURNED TO THE OWNER SHALL BE SAFELY STORED AND PROTECTED UNTIL IT IS REMOVED FROM THE SITE BY THE OWNER. CONTRACTOR SHALL COORDINATE WITH THE ExIST. FLOOR FINISH — OWNER. P RB WALL BASE FINISH SHEET: WALL FINISH LANDLORD/OWNER VALIDITY OF PERMIT SHORENSTEIN REALTY SERVICES THE ISSUANCE OFBASED CONSTRUCTION PERMIT G0m01 5335 MEADOWS ROAD, SUITE 275 LAKE OSWEGO, OREGON 97035 DOCUMENTS AND OTHER DATA SHALL NOT PREVENT THE CODE OFFICIAL FROM CONTACT: ROB FABIAN REQUIRING THE CORRECTION TEL: 503.412.4844 OF ERRORS. OSSC 105.4 JOB NO. EMAIL: RFABIAN@SHORENSTEIN.COM 2190953.10 PERMIT SET: 08/11/2020 •219095303`\\GRP.MCK\PROJECTS\PROJECTS\219095310\DRAWINGS\ARCHITECTURAL\10 GO.01.DWG SW 08/11/20 13:30 1:96.00 GENERAL NOTES 5 3 A. ALL EXISTING CONDITIONS TO REMAIN, UNLESS NOTED OTHERWISE. JOINS 0 B. DIMENSIONS REFLECT FACE OF FINISH TO FACE OF FINISH, UNLESS NOTED OTHERWISE. IS " ° •D tm ° C. WALL THICKNESSES ARE NOMINAL, UNLESS NOTED OTHERWISE. . tA P-2 P- D. FOR SEISMIC BRACING OF SUSPENDED CEILING AND INTERSTITIAL EQUIPMENT SEE DETAILS 1/A5.20. 14 OFFICE OFFICE CONFERENCE E. ELECTRICAL, DATA AND SWITCHING LOCATIONS ARE SHOWN TO CONVEY GENERAL INTENT ONLY. COORDINATE Architecture D Interiors M�51 206 ::. ELECTRICAL/DATA/SWITCHING REQUIREMENTS WITH TENANT AND PROVIDE DRAWINGS BY DEFERRED SUBMITTAL. SE- q�l ° LL .,..56. s LVT-, ° Planning Engineering P-, B, O F. HVAC CONTRACTOR TO PROVIDE FULL SHEET OF THE FLOOR AFFECTED UPON COMPLETION. CONTRACTOR IS 13 11 RESPONSIBLE TO PROGRAM THE OVERRIDE HVAC BUTTON. 1f DD TYP 13 7IQ G. ALL INTERIOR WALLS TO GO TO UNDERSIDE OF GRID UNLESS NOTED OTHERWISE. HALL H. NEW DOORS, FRAMES AND HARDWARE TO MATCH BUILDING STANDARD, PROVIDE V-0" RELITES. 201OR P-2 I. OUTLETS INDICATED ARE EXISTING UNLESS NOTED OTHERWISE. SITE VERIFICATION HAS BEEN PERFORMED (ON Portland, 60 L; 1 - 10 g 503.224.9560 P-1 B-, 2 7 O8 08/06/2020, WHILE UNOCCUPIED) AND PLAN, ELECTRICAL AND CEILING INFORMATION HAS BEEN UPDATED Vancouver, WA • s - • e . p (OBSERVATION IS LIMITED TO VISIBLE/ACCESSIBLE AREAS). CONTRACTOR TO FIELD VERIFY AND CONFIRM ADDITIONAL 360.695.7879 RECEPTION p p REQUIREMENTS WITH TENANT. + z T + 2 T R20 Seattle, WA • BREAK • SERVER 1TYP DD J. NO VOC PAINT SYSTEMS TO BE UTILIZED, TO INCLUDE PRIMERS AS WELL AS FINISH PRODUCTS. 206.749.9993 203 202 s B-, K. PATCH AND REPAIR WALLS WHERE AFFECTED BY NEW CONSTRUCTION. PAINT NEW AND EXISTING WALLS www.mcknze.com u EXIST. H EXIST. 1 ° p-, 10 THROUGHOUT, EXCEPT IN SERVER ROOM.. MACKENZIE. L. CONTRACTOR TO PROVIDE TENANT WITH (1) EXTRA BOX OF CARPET TILE. DESIGN DRIVEN I CLIENT FOCUSED M. EXISTING FLOORING AND BASE TO REMAIN IN BREAK AND SERVER ROOM. 1 4 N. ALL DIMENSIONS SHOWN AS PLUS/MINUS (±) ARE FOR GENERAL LAYOUT AND REFERENCE ONLY.VERIFY AND CONFIRM Client ALL DIMENSIONS AND CONDITIONS PRIOR TO START OF WORK. NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCIES PRIOR TO START OF WORK. 1 DEMOLITION PLAN rTPARTIAL SECOND FLOOR PLAN O. ADD SOUND INSULATION IN ALL NEW WALLS. S H O R E ST E I N P. SUSPENDED ACOUSTICAL TILE CEILINGS AT 9'-0"± (EXISTING) AFF, UNLESS NOTED OTHERWISE. 1/8"=1'-0" Q. FOR SEISMIC BRACING OF SUSPENDED CEILING AND INTERSTITIAL EQUIPMENT SEE DETAIL 1/A5.20. R. CENTER ALL DOWN LIGHTS, FIRE SPRINKLER HEADS, SMOKE DETECTORS AND ALL OTHER CEILING PENETRATIONS IN CENTER OF 2x5 TILE, UNLESS NOTED OTHERWISE. S. COORDINATE ELECTRICAL REQUIREMENTS WITH TENANT,ALL ELECTRICAL DRAWINGS WILL BE BY DEFERRED SUBMITTAL. Project a a ROOM![ m ROOM MOORE![ BEEN![MR ROOM ROOM![ ROOM ROOM![ FINISH SCHEDULE T. HVAC CONTRACTOR TO PROVIDE FULL SHEET OF THE FLOOR AFFECTED UPON COMPLETION. CONTRACTOR IS EDWARD JONES `T RESPONSIBLE TO PROGRAM THE OVERRIDE HVAC BUTTON. SUITE 215 U. REPLACE DAMAGED AND SOILED CEILING TILES WHERE AFFECTED BY CONSTRUCTION TO MATCH EXISTING. TENANT CPT-1: PAT5900 HIGH PRIVATE LABEL PRODUCT; CUSTOM TILE O 24G,LEA INSTALLATION: QUARTER TURN,CARPET ADHESIVE-PATCRAFT V. LIGHTING LAYOUT IS SHOWN FOR PRELIMINARY DESIGN INTENT ONLY. FINAL LIGHTING LAYOUT TO BE PROVIDED BY THE IMPROVEMENT 5900 HIGH MOISTURE(100 YD SPREAD RATE). *GC TO LEAVE 1 CARTON OF CARPET TILE AT BRANCH AT CONSTRUCTION D D ® . COMPLETION. ELECTRICAL CONTRACTOR AND IS DEPENDANT ON OREGON ENERGY CODE ALLOWANCES AND EXISTING BUILDING 4 LINCOLN LVP-1: PATCRAFT RESILIENT, 6"X48" PLANK- RESILIENT VINYL, STYLE: 1800V HIGHLAND FOREST, COLOR: 20220 LIGHT OAK, INFRASTRUCTURE IN CEILING. ELECTRICAL CONTRACTOR TO REVIEW ALL REQUIRED LIGHTING LEVELS AND 10250 SW GREENBURG RD. RESILIENT ADHESIVE PATCRAFT 4100 (700-900 SOFT SPREAD RATE) DISTRIBUTION AND NOTIFY ARCHITECT OF ANY CONCERNS OF FOOTCANDLES OR FIXTURE PLACEMENT/LOCATION TIGARD OREGON P-1: SHERWIN WILLIAMS; SW7029 AGREEABLE GRAY (OR BENJAMIN MOORE; COLLINGWOOD) WITHIN ANY AREA OF THE SPACE. CONFIRM NEW LIGHT FIXTURE PLACEMENT DOES NOT INTERFERE WITH NEW WALL ' ® P-2: SHERWIN WILLIAMS; SW6195 ROCK GARDEN (OR CUSTOM BENJAMIN MOORE"EDJ GREEN" CONSTRUCTION AND SAT MAIN GRID LINES, RELOCATE IF REQUIRED. FINAL LAYOUT TO BE REVIEWED AND APPROVED D RB-1: KOPPE, 4"VINYL COVE BASE, 8100-P100 BLACK BY LOCAL JURISDICTION THROUGH SEPARATE PERMIT. A 12 CONTACT FOR FLOORING: NATIONAL RETAIL FLOORING SERVICES, INC.: �� r� /01 WWW.NRSFINC.COM/EJIFLOORING IRT N636-9922-0200 EDWARDJONES@NRFSINC.COM KEYNOTES 77- 1. EXISTING SINK AND CABINETRY AND EQUIPMENT TO REMAIN, t r, , REG 2. ALIGN NEW WALL WITH EXISTING WALL. f, Lr`=mf 1- 7 3. CENTER NEW WALL ON EXISTING COLUMN. QF O� 4. NEW 08 PAINTED PLYWOOD PHONE BOARD WITH (1) DEDICATED SIMPLEX OUTLET WHERE INDICATED. SEE SERVER ROOM ELEVATION 5/A5.20. 5. PROVIDE BLOCKING, POWER AND DATA FOR TENANT PROVIDED TV IN FA OFFICE. COORDINATE HEIGHT WITH SCOTT © MACKENZIE2019 ALL RIGHTS RESERVED HIRSCHBERGER (503)-475-6446. THESE DRAWINGS ARE THE PROPERTY OF 6. INSTALL NEW TENANT PROVIDED TV. CONFIRM EXISTING HEIGHT IS APPROVED BY SCOTT HIRSCHBERGER. PROVIDE MACKENZIE AND ARE NOT TO BE USED BLOCKING AT TV LOCATION. OR REPRODUCED IN ANY MANNER, WITHOUT PRIOR WRITTEN PERMISSION 5 COMBINED DEMOLITION AND REFLECTED CEILING PLAN 7. PROVIDE BLOCKING FOR TENANT PROVIDED SIGNAGE. SEE 6/A5.20 FOR HEIGHT REQUIREMENTS. 1 8. CONTRACTOR TO ORDER AND INSTALL SIGNAGE (LETTER KIT WITH PINS ON BACK). SIGNAGE PAID FOR BY EDWARD REVISION SCHEDULE'1 1/8"-1 0 JONES, ONLY INSTALLATION WORK TO BE INCLUDED IN SCOPE OF WORK. "EDWARD JONES" LOGO TO BE CENTERED ON EXISTING PARTITION AS INDICATED ON PLAN. SEE 6/A5.20 FOR ACCURATE ALIGNMENT. BOTTOM OF LOGO TO BE Delta Issued As Issue Date 6-0"AFF . COORDINATE WITH TENANT. 9. PROVIDE NEW LOCKING HARDWARE AT SERVER, TO MATCH SUITE STANDARD. 10. INSTALL DOOR CHIME AT ENTRY DOOR. CHIME TO BE LOCATED WHERE INDICATED AT HALL. HAMPTON BAY WIRELESS DOOR ALERT WITH WHITE COVER AND HORIZONTAL LINES - HOME DEPOT MODEL# SL-6168 OR COMPARABLE ROOM![ �110 ]MINOR HOME ROOM ROOM ROOM m ALTERNATIVE. ROOM![ MINOR ROOM 0 11. CONFIRM EXISTING PARTITION WALLS IN CONFERENCE ROOM ARE INSULATED. INSTALL/BLOW IN INSULATION AS 7_7 44- REQUIRED. 12. PROVIDE AND INSTALL 6" RECESSED SPOTLIGHT WITH WHITE ADJUSTABLE EYEBALL TRIM KIT, UTILIZING LED BULB. TO I.J BE INSTALLED IN CEILING 5'-0"AWAY FROM THE WALL AND CENTERED ON LOGO. PROVIDE SEPARATED SWITCH. 44 13. NEW S-0"WIDE T-0" HIGH SOLID CORE FLUSH WOOD DOOR WITH ADJACENT V-0"WIDE RELITE. TIMELEY METAL FRAME 44 . - _ ® " - - o WITH FACTORY FINISH. HARDWARE TO BE PASSAGE LOCKET F75 GRADEI, BUTTS, SEAL, STOPS. SEE DETAIL 7/A5.20. SHEET TITLE: - - C 14. REMOVE CONDUIT ON WALL AS REQUIRED BY NEW WALL PLACEMENT. PATCH, REPAIR AND PAINT WALL. DEMOLITION PLAN, -_ _ _ ® _i_;- PARTIAL SECOND FLOOR PLAN AND NOTES,COMBINED - - . - - - DEMOLITION AND = = _ ° BB 12 ALTERNATE UPGRADES REFLECTED CEILING AF PLAN,ALTERNATE EN PROVIDE SEPARATE PRICING FOR THE FOLLOWING: DEMOLITION REFLECTED CEILING PLAN, B 44._LL _LL _ _ e AA. PROVIDE LED RETROFIT KITS AT EXISTING LIGHT FIXTURES, IN LIEU OF EXISTING TO REMAIN. ASSUME LITHONIA, 2BLTR, ALTERNATE REFLECTED -f-T, 2x4 RELIGHT LED, 3500K. CONFIRM FINAL LIGHT FIXTURE QUANTITY AND LIGHTING CALCULATIONS WITH CONTRACTOR. CEILING PLAN, FINISH - - SCHEDULE AND NOTES - - PROVIDE DIMMER SWITCH. -4- _ _44- BB. IN LIEU OF RETROFIT, PROVIDE BUILDING UNGRADED LED FIXTURES WITH DIMMERS THROUGHOUT. DRAWN BY: SW CC. PROVIDE SOUND ATTENUATION BATT ABOVE CEILING TILES, 4'-0" CENTERED ON WALL AT FA OFFICE AND CONFERENCE . ....... . fT z. ROOMS. DD. PAINT DOOR AND RELITE FRAMES, SHERWIN WILLIAMS CHATEAU BROWN SW7510, IN LIEU OF BUILDING STANDARD. CHECKED BY: MRT, PDK SHEET: s ALTERNATE DEMOLITION REFLECTED CEILING PLAN io ALTERNATE REFLECTED CEILING PLAN AND NOTES A1 . 10 JOB NO. 2190953.10 PERMIT SET:: 08/11/2020 •219095303`\\GRP.MCK\PROJECTS\PROJECTS1219095310\DRAWINGSWRCHITECTURAL\10 A1.10.DWG SW 08/11/20 13:32 1:96.00 FLOOR OR ROOF STRUCTURE POP RIVET RUNNER TO WALL ANGLE AT 2 ADJACENT gERC 2 ■ "4 LINCOLN" STUD SIZE: 236" 33 MIL 3-1/2" METAL WALLS, FASTEN CLOSURE ANGLE W/ #6 SCREWS 8" MAX. STUD BRACING TO FLOOR DIRECTLY TO WALL FRAMING CLIP STRUCTURE AT 8'-0" OC LIMITING WALL HEIGHT TABLE WITH (2) #8 SHEET o METAL SCREWS AT EACH ADDITIONAL #12 WIRE SUPPORT AT ALL MEMBERSu 14TEFOOR NON STRUCTURAL NON-COMPOSITE WALLS L/240 © 5psf END. BRACING TO BE WITHIN 8" OF PERIMETER PROVIDED WHERE ■ LATERAL BRACING WITH APPROVED VERTICAL \ � © o� DEMNATM SPACING MAX WALL HEK3HT DISTANCE BETWEEN COMPRESSION STRUT AT 12'-0" OC EA WAY y ,• 2505125-18 24" 8'-4" PERPENDICULAR COUNTERSLOPE HANGERS IF MORE THAN 1: 6 OUT OF PLUMB 2 - INTERSECTING WALLS OR Architecture R Interiors C 2505725-18 16" 9'-7" HORIZONTAL BRACING �^ BETWEEN WALLS EXCEEDS Planning Engineering "ATTACHED m 250S125-27 24" 9'-10" 4 8'-0" OC WALL" �� , 2505125-18 16" 11'-3" 3" SOUND ATTENUATION OOa 362S125-18 24" 13'-5" BATT. 4'-0" CENTERED ON A CELING EDGE AT WALL 362S125-18 i6" 14'-4" SUSPENDED WALL WHERE NOTED. A NOTE: FOR UNATTACHED WALLS PROVIDE A CEILING CUT TWTILE LS FOR TIGHT FIT Portland, OR 362S162-33 16" 16'-5" AT CASING BEAD USG 200-A 503.224.9560 3/4" GAP BETWEEN EDGE OF ANGLE AND CLIP GYPSUM BOARD Vancouver, WA -- DO NOT SCREW SERC 2 CLIP TO TRACK 362S162-43 16" 18'-0" EACH SIDE ATTACH STUD TRACK 360.695.7879 i CROSS RUNNERS FIT BETWEEN MAIN RUNNERS TABLE MAX. LENGTH 600S162-33 16" 24'-6" THROUGH GRID ` tl� MAIN RUNNERS AT 4'-0" OC SUPPORT WITH #12 1/2" DIA CONDUIT (EMT) 5'-10" SOUND ATTENUATION 2067499 9�3 A 3 4" DIA CONDUIT EMT 7'-g" INTEROR NON STRUCTURAL. NON-COMPO`SIT'E WAL'L'S INSULATION AS OCCURS WIRE AT 4'-0" OC OR WITH #10 WIRE AT 5'-0" OC EA WAY WITH CERAMIC TILE FACING L/360 @ 5psf METAL STUDS. BOTTOM TRACK TO FINISH www.mcknze.com 6'-0" MAX LATERALLY BRACE MAIN RUNNER TO STRUCTURE AT 12'-0" OC 1" DIA CONDUIT EMT 9'-g" SEE WALL HEIGHT FLOOR WITH POWDER EA WAY. BEGIN BRACING WITHIN 6'-0" OF PERIMETER AND 2" 6 - 12'-0" TABLE FOR SIZE DRIVEN ANCHORS AT FROM CROSS MEMBER IN AREAS GREATER THAN 1,000 SF (1-5/8"x2OGA) DESIGNATION SPACING MAX WALL HEX3HT AND SPACING ------ 4'-0" O.C. M AC K E N Z 1 E DESIGN DRIVEN I CLIENT FOCUSED NOTE: ALL GRID MEMBERS AND CONNECTION DEVICES TO BE OF AN BACK TO BACK 162S125-33 15'-0" 362S125-18 16" 12'-4" a CONTINUOUS ACOUSTIC APPROVED TYPE AND HAVE A 180# CAPACITY. ALL LATERAL BRACING SECURE ALL HANGERS TO MTL STUDS 1-5 8"x2OGA 3625125-33 16" 14'-3" SEALANT EACH SIDE Client WIRES TO HAVE A 200# CAPACITY. SUSPENDED CEILING BLDG STRUCTURE. SGL 250S125-33 MTL STUD 13'-6" Cf) N AGAINST TRACK NO BRACING TO COMPLY WITH ASCE7, ASTMC635, ASTMC636 AND TRAPEZE DUCT WORK AND 2-1 2"x2OGA Q SEALANT AT SIMILAR OTHER LARGE WALL TABLES ARE BASED ON WALLS SHEATHED BOTH SIDES FULL HEIGHT WITH U) ` CONDITION ASTME580 BACK TO BACK 250S125-33 OBSTRUCTIONS MTL STUDS (2-1/2"x20GA) 15 -0 1/2" GYPSUM BOARD ATTACHED WITH #6 SCREWS MIN. AT 12"-0" O.C. MAX. m o - CONCRETE SLAB 0 s H o R E s T E 1 N 1 SUSPENDED CEILING BRACING 3 WALL HEIGHT TABLE 4 WALL - TO UNDERSIDE OF GRID CD rJ 2 NOTE: PROVIDE SEISMIC SEPARATION JOINTS IN CEILINGS GREATER NTS z 5 Z ¢ 5 2 AT FLOOR AND SUSPENDED CEILING THAN 2,500 SF. PROVIDE HEAVY DUTY GRID SYSTEM. 3 WALL PER PLAN BOC REOUIREMENTS: Project GYPSUM BOARD WALL AS EDWARD JONES NOTE: CONDUIT IS INSTALLED INSIDE WALL IF WALL IS EXISTING. CONDUIT — — — — — OCCURS MAY BE SURFACE MOUNTED MUST HAVE ROOM FOR EQUPMENT TO INSTALL SUITE 215 ON PLYWOOD. (SEE KEYED NOTE#10N PAGE 2 OF 6 FOR CLARIFICATION-) DOUBLE STUD AT JAMB, TENANT TYPICAL 3i4'CONDUIT TO LEC Y4" CONDUIT TO ALL IMPROVEMENT DMARC BOX ( I I I WORKSTATION LOCATIONS ______ 4 LINCOLN 10250 SW GREENBURG RD. SINGLE GANG PHONE ZO" X Zd' FRT PLYWOOD, PAINTED BOX WITH PULL STRING TO MATCH WALL WLGEL TIMELY FRAME TIGA OREGON AND#6 GROUND WIRE EXPOSED, INSTALL AT 360AF.F, EDWARD JONES BY GC(INC TO RUN (i) TO BOTTOM; BOARD SUPPLIED& o Q CATSE LINE TO THIS INSTALLED BY GC. a) a ��gPORT NG f� LOCATION) UJ Ud DEDICATED SIMPLEX OUTLET TO ACTIVE SINGLE GANG BE MARKED WITH V&ORANGE INDICATE DEDICATED BY GC. z 1/4" TEMPERED RELITE , REG PHONE BOX WITH PULL w aT AS OCCURS, PROVIDE BY GC F- -I "C" CHANNEL AT TOPCL 9 ' �F pg STRIRLW NGS REMAMdI6NG ;) DOUBLE GANG PHONE BOXES,GC LU W AND BOTTOM CATSE LINES TO THIS � ) ( ( TO RUN PULL STRING THROUGH n LOCATION) STUD EACH CONDUIT RUN.INC TO RUN © ALL RIGHTSZRESERVED REMAINING CABLES TO VARIOUS WORKSTATION LOCATIONS 'SEE THESE DRAWINGS ARE THE PROPERTY OF MACKENZIE AND ARE NOT TO BE USED LOW VOLTAGE WIRING SPECS OR REPRODUCED IN ANY MANNER, WITHOUT PRIOR WRITTEN PERMISSION W > 5 SERVER ELEVATION s SIGNAGE ELEVATION w 7 DOOR - TIMELY RELITE REVISION SCHEDULE I Delta Issued As Issue Date J.2 (FOR REFERENCE ONLY) NTS rJ 2 EXISTING DOOR AT CONFERENCE 206 1/4"=1'-0" o cJ 2 HEAD SIMILAR 3"=1'-0" o 0 0 SHEET TITLE: INTERIOR DETAILS AND ELEVATIONS DRAWN BY: SW CHECKED BY: MRT, PDK SHEET: A5m20 JOB NO.2190953.10 PERMIT SET: 08/11/2020 •219095303'\\GRP.MCK\PROJECTS\PROJECTS\219095310\DRAWINGS\ARCHITECTURAL\10 A5.20.DWG SW 08/11/20 13:33 1:96.00