Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
BUP2019 -00303 SW 72ND AVENUE nN Cj-- -- TENANT IMPROVEMENT #3082MARTIN W. H u �r ar F�r5, for ti CLA KA' S, OREGON �y ���JJJ F u �- s� c c PACTR U ST �F Og > RECE1 ��o Tenant: NOV 7 2s��9 PROJECT #19370 �� �� NulL,PERFORMANCE SYSTEMS INTEGRATION CORP BUILoFTIGPR® DING DIVtSI©N BUILDING LOCATION PROJECT NARRATIVE G M PROJECT CONSISTS OF REMODEL WORK TO 11 ,102 SF OF EXISTING OFFICE AND -� e° \ WAREHOUSE SPACE. WORK SHALL INCLUDE BUT NOT BE LIMITED TO DRYWALL/METAL i STUDS, SUSPENDED CEILINGS, DOORS/FRAMES AND PAINTING. ALL WORK TO MEET ADA Q REQUIREMENTS. O o �_ SITE MAP — --- To Tec I a II A-o NOT TO SCALE Z� WORK INCLUDED BUT PERFORMED UNDER SEPARATE PERMIT (� Y o � = QNr- 0 (M FIRE PROTECTION SPRINKLERING ClpCc) � HEATING, VENTILATION & AIR CONDITIONING WORK � o ELECTRICAL WORK, BOTH LINE VOLTAGE AND LOW VOLTAGE -� � a N N 1 2 3 4 5 6 7 8 --- - - -- cu 5 0 I, M M oD 20'-0" 20'-0" 4 BAYS @ 25'=1 'NOM. 20'-0" L A — — — BUILDING INFORMATION _ - --------------------------- ------------------------- -- ------------ ---------------- , OWNER: PACIFIC REALTY ASSOCIATES, L.P. m 15350 SW SEQUOIA PKWY #300 co 9 PORTLAND, OR 9722400 ' 20'-0" v l (503) 624-6300 (PHONE) a ----------------- - (503) 624-7755 (FAX) -- - ' BLDG. #: pbc198 (BLDG. H) rO CONST. TYPE.: V-B FULLY SPRINKLERED z 10 O 25'NOM. THIS BUILDING HOUSES MULTIPLE TENANTS. THE EXISTING BUILDING IS A SINGLE STORY BUILDING C - - - - - - - - ' L - - , OF 21 ,180 SF AND IS FULLY SPRINKLERED. THERE IS FRONTAGE ON ALL FOUR SIDES OF AT LEAST a 60 FEET. 9 ACTUAL BUILDING AREA TOTALS 04. � ' w B OCCUPANCY = 13,077 SF z - � � S-1 OCCUPANCY = 8,073 SF ' TOTAL 21 ,150 SF ' J MIXED OCCUPANCY - NON-SEPERATED USES. (OSSC 508.3) uJ ALLOWABLE AREA IS UNLIMITED. (OSSC 507.3)100 �-- U) F - - -� -- - - �- - - -- - - - - - - TENANT INFORMATION TENANT: PERFORMANCE SYSTEMS INTEGRATION CORP W OFFICE COPY w W ' OCCUPANCY AREAS & LOADS: z z B 7,691 SF 77 OCC S-1 3,411 SF 7 OCC Q o N TOTAL 11 ,102 SF �75;�// Z_ AREA OF WORK NUMBER OF EXITS REQUIRED o 2 OVERALL BUILDING PLAN z B 2 EXITS � A-0 1/32" = V-0° Z S-1 1 EXITS w � � CODESUMMARY MARY _ - VALIDITY OF PERMIT 11/1/19 ALL CONSTRUCTION WORK SHALL BE DONE IN COMPLIANCE WITH STATE AND LOCAL CODE THE ISSUANCE OFAPERMIT PERMIT / CONST BASED ON CONSTRUCTION REQUIREMENTS THAT APPLY, INCLUDING BUT NOT LIMITED TO: DATASHALLTR REVISION • 2014 OREGON STRUCTURAL SPECIALTY CODE (OSSC) DATATHE SH LLNOTIAL PREVEN FROM • 2014 OREGON MECHANICAL SPECIALTY CODE (OMSC) REQUIRING THE CORRECTION 1 • 2014 OREGON PLUMBING SPECIALTY CODE (OPSC) OF ERRORS. OSSC 105.4 • 2014 OREGON ELECTRICAL SPECIALTY CODE (OESC) 2. • 2014 OREGON FIRE CODE (OFC) 3' • ASCE-7-10 4. • ICC/ANSI A117.1-2009 5. • 2014 OREGON ENERGY EFFICIENCY SPECIALTY CODE CITY OFTIGARD 6. RT✓VIE FOR CODE COMPLIANCE 7. Approve tel"` ] 8 OTC: N I Permit #: DRAWN BY: Address: "�y' C} <w �� ham... red R.M.T. Suite M. By: 71= Date: 01 00 00 GENERAL DATA 6. WATER RESISTANT GYPSUM BOARD SHALL BE 5/8"THICK WITH TAPERED EDGES. CONFORMING TO ASTM RPROJECT #19370 GENERAL REQUIREMENTS 0-630. DETAIL GENERAL NOTES: 'C' 1. VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON DRAWINGS AND AT THE EXISTING BUILDING AND 7. AT TOILET ROOMS USE 5/8"USG FIBERROCK BRAND AQUATOUGH INTERIOR PANEL FROM FLOOR TO 48"A.F.F.ON WALLS BEHIND OR ADJACENT TO PLUMBING FIXTURES. NO SUBSTITUTES. 1. FOR WALLS UP TO 14'-0"TALL, USE 36251 25-30 MTL. STUDS 24"O.C. UNLESS NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING THE WORK. @ ,f'(EXCEPTION: EXCEPTION AT LOCATIONS TO RELIEVE PLASTIC LAMINATE OR TILE WAINSCOT.) �12. CONTRACTOR AND ALL SUBCONTRACTORS SHALL PERFORM DUE DILIGENCE INSPECTION OF ALL EXISTING , " CALLED OUT OTHERWISE IN DETAIL. USE 362T125-30 MTL. TRACK.CONDITIONS PRIOR TO SUBMITTAL OF A PROPOSAL.SUBMITTAL OF A PROPOSAL SHALL BE CONSIDERED 8. AT TILE WAINSCOT LOCATIONS INSTALL CEMENT BACKER BOARD /: THICK WITH SQUARE,REINFORCED, NSONCONFIRMATION THAT SUCH INSPECTION HAS BEEN MADE,AND NO FURTHER COMPENSATION SHALL BE DUE SMOOTH EDGES. PROVIDE DUROCK BRAND CEMENT BOARD OR APPROVED EQUAL. 2. FOR WALLS OVER 14'-0"TALL, USE 600$1 25-33 MTL. STUDS @ 16"O.C. UNLESSTHE CONTRACTOR FOR CLAIMS ARISING AS A RESULT OF FAILURE TO PERFORM SUCH INSPECTION. 9. INSTALL WATER-RESISTANT GYPSUM BOARD BEHIND WAINSCOT OF FRP,PLASTIC LAMINATE,ETC. CALLED OUT OTHERWISE IN DETAIL. USE 600T125-33 MTL. TRACK. 3. BY SUBMITTING A PROPOSAL,CONTRACTOR AND ALL SUBCONTRACTORS CERTIFY THAT THEY HAVE 10.TRIM ACCESSORIES SHALL COMPLY WITH ASTM C-1047. 3. ALL WALLS: ATTACH BOTTOM TRACK TO FLOOR WITH POWDER DRIVEN REGON,1EXAMINED THE SITE AND INCLUDED IN THEIR PROPOSAL ALL WORK NECESSARY TO COMPLETE THE WORK 11.USE GEORGIA PACIFIC DENSGLAS GOLD ON EXTERIOR FACE OF EXTERIOR WALLS AND COAT WITH STO FINISH ANCHORS AT 24"O.C. �QDESCRIBED OR REASONABLY IMPLIED IN THESE DOCUMENTS. THIS INCLUDES BUT MAY NOT BE LIMITED TO SYSTEM. ROOF DECK ALL MATERIALS AND INSTALLATION, DISPOSAL OF EXCESS MATERIALS(USEABLE FINISH MATERIALS SHALL BE 4. IN WALLS WITH ACOUSTIC INSULATION, SET BOTTOM TRACK IN BED OF SEALANT.LEFT IN THE TENANT SPACE AS NOTED ON PLANS),CLEANING AND ALL PREPARATION OF SUBSTRATE WALL CONSTRUCTION EXECUTION jI t �4OR BEAM OgSURFACES PRIOR TO INSTALLATION,AS WELL AS FINAL CLEAN UP. 1. FASTEN FRAMING MEMBERS TOGETHER BY WELDING OR BY USING SELF-DRILLING OR SELF-TAPPING �' 115. FOR WALL FINISHES, FLOOR FINISHES AND WALL BASE TYPE, REFER TO 4. IT IS THE INTENT OF THESE CONTRACT DOCUMENTS TO MATCH AND MAINTAIN EXISTING BUILDING SCREWS. WELDING SHALL CONFORM TO AWS D13 WELDING PROCEDURE. ELECTRODES AND SCREW Ia 1 f I PROJECT FINISH SCHEDULE. STANDARDS FOR ALL EXISTING PRODUCTS AND SYSTEMS. UPON DISCOVERY OF A DISCREPANCY TO THIS CONNECTIONS SHALL BE AS REQUIRED AND INDICATED IN THE DESIGN CALCULATIONS. DO NOT FIELD V'lINTENTION,THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY. MATERIALS LIGHTER THAN 18 GA. POWDER DRIVEN ANCHORS 19370 5. FURNISH ALL NEW MATERIALS EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE. 2. PROVIDE ACCURATELY ALIGNED RUNNERS AT TOP AND BOTTOM OF PARTITIONS. ANCHOR TRACKS AS SUSPENDED CLG ASSEMBLY '- 6. COORDINATE THE WORK OF ALL TRADES. PROVIDE CARPET"WALK-OFF MATS"TO PROTECT EXISTING INDICATED IN THE DESIGN CALCULATIONS. BUTT WELD JOINTS IN TRACKS OR SPLICE WITH STUD INSERTS. STRUCTURAL SUPPORTING CALLS" CARPETS. FASTENERS SHALL BE AT LEAST 3 INCHES FROM THE EDGE OF CONCRETE SLABS. 7. ALL ROOF PENETRATIONS FROM ABANDONED EQUIPMENT TO BE REMOVED. PATCH AND REP;IR ROOF AND3. CUT STUDS SQUARE AND SET WITH FIRM BEARING AGAINST WEBS OF TOP AND BOTTOM TRACKS. POSITION 1. POWERS 0.300 HEAD (3/4"EMBED)0.145 SHANK DIAMETER STUDS VERTICALLY IN TRACKS AND SPACE AS INDICATED IN DESIGN. DO NOT SPLICE STUDS. PROVIDE AT ROOF MEMBRANE TO MATCH THE EXISTING ROOF. LEAST TWO FULL HEIGHT KING STUDS AT DOORS AND OTHER OPENINGS 2 FEET WIDE OR LARGER. PROVIDE ALLOWABLE SHEAR=70 LBS 45" _0 8. ALL ROOF WORK TO BE PERFORMED BY PACTRUST APPROVED ROOFING COMPANIES. APPROVED JACK STUDS OVER OPENINGS,AS NECESSARY,TO MAINTAIN INDICATED STUD SPACING. PROVIDE TRIPLE :�,r. ::.; .L : •r COMPANIES INCLUDE: STUDS AT CORNERS, POSITIONED TO RECEIVE INTERIOR AND EXTERIOR FINISHES. FASTEN STUDS AT TOP 2. 12' O"TALL WALL WITH CODE REQUIRED 5 PSF MINIMUM LATERAL a: .•c.:• .. _.. .-...: . t..-....r. AND BOTTOM TRACKS BY WELDING OR SCREWING BOTH FLANGES TO THE TRACKS.PROVIDE LONG LEG (WIND) LOAD SHEAR=5 PSF' 12'-0"12=30 PLF a. ARROW ROOFING, 503460-2767 TRACK AT TOP OF WALL TO ALLOW FOR DEFLECTION WHERE WALL MEETS STRUCTURE ABOVE. z' 20 GA 3 5/8" METAL STUD BRACING f� b. PACIFIC ROOFING,503-640-31633. ANCHORS AT 16"O/C _ r 4. INSTALL ALL INTERIOR AND EXTERIOR GYPSUM BOARD PRODUCTS AND ACCESSORIES AS REQUIRED FORTO ROOF STRUCTURE AT 10'-0" i c. ROOF TOPPERS,360-574-7248 THE PROJECT. SHEAR=30 PLF " 16"/12"=40 LBS OC W/(2)#8 SHEET METAL d. GOT YOU COVERED ROOFING,503-975-913 5. AT TOILET ROOMS TO RECEIVE SHEET VINYL FLOORING, INSTALL THE GYPSUM BOARD(OR AUQATOUGH) 4. UNITY CHECK SCREWS AT EACH END. BRACING L 10.KEEP THE AREA OF WORK FREE OF GARBAGE AND DEBRIS ON A DAILY BASIS INCLUDING DOCK ACCESS WITH 1/4"GAP BETWEEN THE BOARD AND THE FLOOR TO PREVENT WICKING. 40 LBS/70 LBS =0.57< 1.0 OK ,f j' TO BE PROVIDED WHERE DISTANCE AREAS AND COMMON AREA. FLOORS TO BE SWEPT OR VACUUMED DAILY. 6. COMPLY WITH USG GYPSUM CONSTRUCTION HANDBOOK AND MANUFACTURER'S RECOMMENDATIONS. 5. ANCHORS AT 24"O/CBETWEEN PERPENDICULAR INTERSECTING 11.PROVIDE ADEQUATE PROTECTION TO ALL EXISTING IMPROVEMENTS INCLUDING BUT NOT LIMITED TO 7. FINISH QUALITY: SHEAR=30 PLF "24"/12"=60 LBS WALLS OR HORIZONTAL BRACING COMMON CORRIDORS AND STAIRS,BUILDING ENTRANCES,SUITE ENTRANCES,ETC. THE CONTRACTOR WILL F. AREA PROCESS TRADE NOMENCLATURE BETWEEN WALLS EXCEEDS 12'4"OC C O BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGES TO EXISTING IMPROVEMENTS DUE TO CONSTRUCTION 6. UNITY CHECK ACTIVITIES. WAREHOUSE TAPE/FINISH COAT` TIGHT DOUBLE(LEVEL 3) O C7 12.PROVIDE TEMPORARY SANITARY FACILITIES. CONSTRUCTION WORKERS SHALL NOT USE BUILDING OFFICE/OTHER AREAS TAPE/2 FINISH COATS`/ SMOOTH FINISH TAPED(LEVEL 4) 60 lbs 170 Ib5= 0.86 < 1.0 OK '^ Mit RESTROOM FACILITIES. USG"FIRST COAT" `SAND AFTER TAPE/FINISH COAT(S) 13.STORAGE AND STAGING OF CONSTRUCTION MATERIALS SHALL BE LIMITED TO AREAS AS DESIGNATED AT NOTE:AT EXTREMELY DARK ACCENT WALLS PROVIDE LEVEL 5 FINISH. 1 GENERAL NOTES r_5 '� WALL BRACING DETAIL PRE-CONSTRUCTION MEETING. UNDER NO CIRCUMSTANCES SHALL BUILDING UTILITY AREAS OR ANY OTHER cuY COMMON BUILDING AREA BE USED FOR STORAGE. SCALE 1�� = 1'-0" A-1 " _ o_ N B. FINISH EXPOSED INTERIOR GYPSUM BOARD WALLS AND CEILINGS SMOOTH STRAIGHT READY FOR FINISH AS SCALE 3 1 -� 14.KEEP THE ROOF FREE OF DEBRIS(I.E.NAILS,SCREWS, BOTTLES,ETC.)AT ALL TIMES. SHOWN ON PLANS. Q n 15.ALL DIMENSIONS ARE TO FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. 09 53 00 SUSPENDED ACOUSTICAL CEILING O O) 16.CONFIRM SIZES OF ALL OPENINGS REQUIRED FOR THE INSTALLATION OF STRUCTURAL,MECHANICAL, 20 GA 3 5/8" METAL STUD BRACING TO ROOF Z) M 1. IN EXISTING SPACES REPLACE WATER STAINED OR DAMAGED TILES. ELECTRICAL AND PLUMBING WORK PRIOR TO FRAMING OR CUTTING FOR INSTALLATION. STRUCTURE AT 10'-0"OC TO BUILDING STRUCTURE W 00 � 17.LEAVE THE PROJECT CLEAN AND READY FOR OCCUPANCY. 2. TUNE UP GRID SYSTEM TO WITHIN PLUS OR MINUS 0.5 INCHES OF LEVEL. 2'-0" 2'-0" ABOVE FOR WALLS LONGER THAN 12'-0"WITHOUT M I� 3. BENT OR DAMAGED T-BARS To BE REPLACED. INTERSECTION WALLS. FASTEN EACH END WITH C CD 1- 18.CLEAN ADJACENT EXTERIOR AREA, I.E.WALKS,EXTERIOR GLASS,ETC. � Z � � 4. REPAIR HOLES IN GRID FROM REMOVED WALLS. USE OF ARMSTRONG"BP ES-4"EXPANSION SLEEVE 1 #8 SHEET METAL SCREW .�..+ 19.FILL ALL PAPER AND SOAP DISPENSERS IN RESTROOM$AND BREAK AREAS. ( ) L U) !5 N N ACCEPTABLE. co CD 20.CLEAN ALL SUPPLY AND RETURN DIFFUSERS AT PROJECT COMPLETION. TYPICAL STUD 09 9123 PAINTING SOUND INSULATION 4'CENTERED cu Lo D_ M M 21.PROVIDE"AS-BUILT"DRAWINGS OF THE WORK AT THE CONCLUSION OF CONSTRUCTION."AS-BUILT" M 0 0 INTERIOR: OVER WALL LO DRAWINGS MAY BE IN THE FORM OF TWO COPIES OF CONSTRUCTION DOCUMENTS MARKED-UP WITH RED � a v v PEN.DELIVER RECORD DRAWINGS TO THE ARCHITECT. COMPLETE OPERATION AND MAINTENANCE MANUALS 1. WALLS: SUSPENDED CEILING SHALL BE PROVIDED FOR ALL MECHANICAL, ELECTRICAL AND PLUMBING EQUIPMENT.PROVIDE AS-BUILT CAD a. PRIME NEW DRYWALL WITH MILLER PAINT HIGH-BUILD"SUPER SEAL"PRIMER. FILES TO PACTRUST FOR ALL MEP TRADES.PACTRUST MAY HOLD CONTRACTOR'S FINAL PAYMENT UNTIL BLOCKING TYPICAL AT FASTENING POINTS. ^ "AS-BUILT"DRAWINGS AND O&M MANUALS HAVE BEEN RECEIVED AND APPROVED. b. NEW AND EXISTING DRYWALL TO BE FINISHED TO ACHIEVE UNIFORM COVERAGE WITH MILLER PAINT _ 22.IT IS THE INTENT OF THE CONTRACT DOCUMENTS THAT THE CONTRACTOR PROVIDE A COMPLETE, 120-4-XX WITH A TIGHT ROLLER STIPPLE FINISH. RESTROOM FINISHES TO BE MILLER PAINT 170-5-XX S/G TYPICAL TRACK FUNCTIONING PROJECT INCLUDING ALL GENERAL,MECHANICAL AND ELECTRICAL CONSTRUCTION REQUIRED LATEX ENAMEL. TO FULFILL THAT INTENT. ALL ITEMS REQUIRED SHALL BE FURNISHED AND INSTALLED,REGARDLESS OF 2. DOORS AND FRAMES: MTL. STUDS. INSTALL STUDS WITH WHETHER OR NOT SHOWN ON THE DRAWINGS. ��. m a. NEW HOLLOW METAL-PRIME, SAND,AND FINISH WITH TWO COATS OF SEMI-GLOSS OIL.SPRAY OR 5/8"GYP. BIRD. BOTH SIDES SAME DIMENSION (10" i 23.ITEMS OR WORK NOT TO BE FURNISHED OR ACCOMPLISHED BY CONTRACTOR ARE NOTED"N.I.C.". ROLLED APPLICATION. F MIN.) FOR BRIDGING 00 24"ALIGN"AS USED IN THESE DOCUMENTS,MEANS TO ALIGN THE FINISHED FACES OF ELEMENTS IN THE SAME b. EXISTING HOLLOW METAL-SAND,FILL IMPERFECTIONS WITH BONDO,SAND AND PRIME PATCHES WITH Z = ALIGNMENT PLANE,EITHER IMMEDIATELY ADJACENT TO ONE ANOTHER OR ACROSS AN OPENING. ALKYD PRIMER,AND FINISH WITH SEMI-GLOSS OIL ENAMEL.SPRAY OR ROLLED APPLICATION d W CENTER LINE OF STUD �0 25.DO NOT DISASSEMBLE SETS OF CONSTRUCTION DRAWINGS.DRAWINGS ARE INTERRELATED. c. WOOD-PRIME WITH ALKYD OIL UNDER-COATER,SAND,FILL ALL FASTENING HOLES WITH PAINTER'S W = ---------- ,, J C1 26.SUBMIT SAMPLES OR DRAW DOWNS FOR ALL FINISHES REQUESTED TO THE ARCHITECT OF RECORD WITHIN PUTTY,CAULK ALL CRACKS IN CASINGS AND BETWEEN JAMBS AND WALLS USING DAP LATEX CAULK, W 0_ EL. TWO WEEKS OF PROJECT AWARD.PRODUCTS INSTALLED WITHOUT APPROVED SAMPLES ARE SUBJECT TO AND FINISH WITH SATIN OIL ENAMa)REPLACEMENT AT CONTRACTOR COST.AN tl � POWDER DRIVEN LT.YL REQUIREMENT TO PROVIDE THE SPECIFIED ITEMS UNLESS SPECIFICALLY PPROVED SUBMITTAL N TED AS A SUBSTITUTION BYL.NOT CHANGE THE ATHE ----- d. WOOD-STAIN,SEAL AS REQUIRED,AND VARNISH WITH SATIN VARNISH. - - _ _ _ _ 3-1/2" BATT INSULIN SOUND ATTENUATION WALLS . - �, �� ,r - ANCHORS AT 24"C.C. - - -- - -- y-� -- CONTRACTOR AND SPECIFICALLY APPROVED BY THE ARCHITECT AS SUCH.REPLACE SUCH PRODUCTS AS 3. CEILINGS: � `f DIRECTED AT CONTRACTOR'S COST. a. EXISTING GYP BOARD/PLASTER-SAND,SPACKLE ALL IMPERFECTIONS,SPOT PRIME AND FINISH TO N� (1)#10-16 SCREW I 27.SUBMIT COMPLETE SHOP DRAWINGS FOR MILLWORK,SPECIAL SYSTEMS, MECHANICAL,ELECTRICAL AND ACHIEVE UNIFORM COVERAGE WITH MILLER PAINT 6200 OR 4480. BOTTOM TRACK. ��� PER STUD FLANGE v PLUMBING SYSTEMS(INCLUDING FIRE PROTECTION SYSTEMS). SUBMIT A MINIMUM OF TWO COPIES OF ALL b. NEW GYP BOARD/PLASTER -PRIME WITH SUPER SEAL AND FINISH TO ACHIEVE UNIFORM COVERAGE SHOP DRAWINGS FOR REVIEW AND APPROVAL TO THE ARCHITECT OF RECORD.ARCHITECT WILL RETAIN ONE WITH MILLER PAINT 6200 OR 4480. AT NEW WALLS WITH z COPY AND ONE COPY WILL BE RETURNED TO THE CONTRACTOR. 4. GENERAL NOTES: ACOUSTIC INSULATION, 28.THE DESIGN OF FIRE PROTECTION SYSTEMS IS THE RESPONSIBILITY OF THE FIRE PROTECTION SYSTEMS a. KEEP ALL HARDWARE,HINGES,AND DOOR KNOBS CLEAN OF ALL PAINT SPLATTERS,DRIPS,OR ROLLER FINISH FLOOR-TOP OF SLAB SET STUD TRACK INA O CONTRACTOR.ALL FIRE PROTECTION SYSTEMS SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER SPRAY. LICENSED BY THE APPROPRIATE JURISDICTION FOR THE DESIGN OF THIS TYPE OF SYSTEM. COORDINATE CONTINUOUS BED OF INTERFACE WITH EXISTING BUILDING SYSTEMS AND WITH ARCHITECT. ALL SPRINKLER HEADS SHALL BE b. ALL SURFACES TO BE SANDED BETWEEN COATS, PRIOR TO INSTALLATION OF NEXT COAT. SEALANT U.N.O. CENTERED IN CEILING TILE(OR 2 x 2 MODULE OF A SECOND LOOK II TYPE OF CEILING TILE WHERE APPLICABLE). LOCATION OF THOSE IN GYPSUM BOARD CEILINGS SHALL BE PRE-APPROVED IN WRITING BY c. DURING PROGRESS OF WORK,KEEP JOB SITE CLEAN OF ALL PAINT MATERIALS, RUBBISH,CANS,AND THE ARCHITECTALL COR TO INSTALLATION. RAGS AT THE END OF EACH DAY. < d. UPON COMPLETION OF WORK,CLEAN ANY PAINT SPLATTER BY USING PROPER METHODS OF WASHING WALL SECTION WITH SOUND INS. © WALL BASE DETAIL 29.000RRUPTIO ALL CONSTRUCTION SEQUENCING WITH PACTRUST AND SCHEDULE ALL SERVICE AND SCRAPING,USING CARE NOT TO SCRATCH OR DAMAGE FINISHED SURFACES. �� _ �� A-1 �� _ V-10" - �� INTERRUPTIONS OUTSIDE NORMAL BUSINESS HOURS TO MINIMIZE INCONVENIENCE TO CURRENT TENANTS. A-1 SCALE 1 1 -0 SCALE 3 1 0 f 1'1 GENERAL e. PROTECT WORK OF OTHER TRADES. V 1. REMOVE ALL EXISTING VCT,SHEET VINYL,ETC.IN AREAS WHERE NEW FLOOR COVERING IS SPECIFIED PRIOR f. PROVIDE"WET PAINT"SIGNS AS REQUIRED TO PROTECT NEWLY PAINTED FINISHES. 3 W TO INSTALLATION OF NEW FLOORING. 10 00 00 SPECIALTIES 2. ALL ROOF PENETRATIONS FOR ELECTRICAL,LOW VOLTAGE,GAS PIPING,ETC.SHALL BE SLEEVED THROUGH 10 44 16 FIRE EXTINGUISHERS A LEAD ROOF JACK,CLAMPED WITH A STAINLESS STEEL CLAMP AND SEALED WITH VULKEM 921 7 POLYURETHANE SEALANT. SILICONE SEALANT NOT PERMITTED. 1. FIRE EXTINGUISHER 2A10 BC (WALL MOUNTED OR IN SEMI RECESSED CABINET AS INDICATED ON PLAN) Z 07 00 00 THERMAL&MOISTURE PROTECTION 2. FIRE EXTINGUISHER CABINET: JL INDUSTRIES ACADEMY SERIES MODEL#C1027V10. 1. REPLACE ALL MISSING AND DAMAGED ROOF AND WALL INSULATION ABOVE THE CEILING GRID. 12 00 00 FURNISHINGS BLDG. FLOOR OR ROOF STRUCTURE Fem u) 2. PROVIDE NEW ROOF INSULATION TO MATCH EXISTING AT ABANDONED MECHANICAL UNITS. 1. CLEAN/REFURBISH EXISTING BUILDING STANDARD BLINDS AT ALL EXTERIOR GLASS. SEALANT IN 1/2"SPACE, EA SIDE. 3. AT ALL UN-USED EXISTING ROOF PENETRATIONS,REMOVE EQUIPMENT AND REPAIR ROOF SYSTEM. 21 00 00 FIRE SUPPRESSION : DESIGN /BUILD DEFLECTION CHANNEL 08 10 00 DOORS AND WINDOWS 1. ADJUST EXISTING SPRINKLERS THROUGHOUT SPACE AS REQUIRED BY CODE. SPRINKLER HEADS SHALL BE W CENTERED IN 2 X 2 CEILING TILE.LAYOUT OF SPRINKLERS BY CONTRACTOR, SPRINKLER LAYOUT IN ALL HARD BATT INSUL. 1. RE-USE EXISTING DOORS AND FRAMES WHERE POSSIBLE CEILING AREAS(GYPSUM BOARD/PLASTER)TO BE REVIEWED AND APPROVED BY ARCHITECT PRIOR TO 2. PATCH AND REPAIR ALL HOLES OR DAMAGE TO EXISTING STORE FRONT WINDOWS AND DOORS.TOUCH UP INSTALLATION. MTL. STUDS. FINISH FOR AS NEW LOOK. 2. IN NEW CEILING GRID SYSTEMS OVER 144 SF PROVIDE FLEXIBLE HEADS FOR MINIMUM SEISMIC 5/8" GYP. BD. 3. TOUCH UP ALL EXISTING INTERIOR DOORS AND FRAMES FOR AS NEW LOOK. MOVEMENT. NO"OOPS RINGS ALLOWED". BOTH SIDES SCREW ATTACHED /1 4. OVERHEAD DOORS;WAYNE DALTON THERMOSPAN 125, EXTERIOR WHITE/STUCCO. FLUSH STEEL INSULATED, 26 00 00 ELECTRICAL : DESIGN /BUILD t/1 2"THICK;STANDARD LIFT OPERATING STYLE WITH TRACK AND HARDWARE. OPERATION;PULL ROPE FORF- V J DOORS TO 10'TALL,CHAIN HOIST FOR TALLER DOORS. GENERAL Z m 5. TUNE UP EXISTING OVERHEAD DOORS FOR SMOOTH OPERATION. WORK INCLUDES: 1. ALL ELECTRICAL FEEDS OUTLETS,SWITCHES, ETC.MUST BE VERTICAL DROPS FROM ABOVE EXCEPT FOR 0_ W W lY HORIZONTAL RUNS UNDERR WINDOWS AND RECEPTACLES ON THE SAME STUD. w = a. ADJUST OVERHEAD SPRING TENSION TO MEET MANUFACTURER'S SPECIFICATIONS. 2. ALL ELECTRICAL FEEDS TO OUTLETS AND DATA BELOW WINDOW SILLS TO BE ROUTED THROUGH BUILDING W0_ W b. REPLACE TOP AND BOTTOM DOOR SEALS AS NEEDED. SHELL WALLS. DO NOT FEED FROM PERPENDICULAR INTERIOR PARTITIONS. L U W 1A IL c. REPLACE BENT TRACKS AND PANEL SECTIONS. 3. PROVIDE LABELS AT EACH ELECTRICAL RECEPTACLE IDENTIFYING CORRESPONDING PANEL AND BREAKER. L d. REPLACE ROLLERS AND HINGES AS NEEDED. 4. PROVIDE TYPEWRITTEN UPDATED SCHEDULE AT PANEL TO IDENTIFY CIRCUIT BREAKERS. V e. REPLACE ROPES AS NEEDED. 5. VERIFY ELECTRICAL METER AND TAG METER WITH THE TENANT'S ADDRESS OR SUITE NUMBER. METER \\\ � N f. LUBRICATE ROLLERS IDENTIFICATION NUMBER AND TENANT ADDRESS INFORMATION SHALL BE GIVEN TO PACTRUST PRIOR TO W n TENANTS MOVE-IN, CENTER LINE OF STUD ��// Z rn 09 00 00 FINISHES 6. ELECTRICAL CONTRACTOR TO PROVIDE EMERGENCY LIGHTING IN EXIT PATH SHOWN ON PLAN EQUAL TO Q GENERAL 1-FOOT CANDLE. BOTTOM TRACKO m 1 O 1. CLEAN,SEAL AND WAX ALL RESILIENT FLOORS PER MANUFACTURERS SPECIFICATIONS.EXCLUDES LVT. 7. EXIT LIGHTS:RUUD LIGHTING"PLASTIC LED EXIT SIGN"MODEL EXPBURWH RED LETTERS,WHITE SEALANT IN 1/2"SPACE, EA SIDE. WITH BATTERY BACKUP. 2. SUBMIT SAMPLES OR DRAW DOWNS FOR THE FOLLOWING: HOUSING, FINISH FLOOR-TOP OF SLAB u� (n � Z a. FLOOR COVERINGS, BASE AND TRANSITION STRIPS 8. WHERE NEEDED,CONTRACTOR TO FURNISH AND INSTALL NEW DRY TYPE TRANSFORMERS TO PROVIDE +�+� 208V/120V POWER FROM THE 480V1277V SYSTEM. SIZE TO BE BIDDER DESIGN. > g b. PLASTIC LAMINATES a. TRANSFORMERS TO BE ENERGY STAR LABELED. W c. ALL NATURAL WOOD(INCLUDING DOORS AND CASEWORK) b. CASE TO BE TOTALLY ENCLOSED WITH LOUVERS TO PREVENT FOREIGN OBJECTS INTO THE INTERIOR. CV d. PAINT c. ENCLOSED AND VENTILATED,AIR COOLED TYPE,CLASS H INSULATION,DESIGNED FOR 115 DEGREES C FULL HEIGHT WALL a a a e. TILE,MARBLE,GRANITE,STONE,GROUT AND SCHLUTER TRIMS TEMPERATURE RISE ABOVE 40 DEGREES C AMBIENT TEMPERATURE AT FULL LOAD CONTINUOUS A-1 SCALE 1" = 1'-0" f. TOILET PARTITIONS OPERATION. EQUIP WITH 2-1/2 PERCENT ANFC TAPS AND FOUR 2-1/2 PERCENT BNFC TAPS. MAXIMUM 11/1/19 SOUND LEVEL SHALL BE NEMA STANDARD WITH ISOLATION DAMPERS BETWEEN THE CORE AND COIL g. HARDWARE ASSEMBLY AND CASE. PERMIT / CONST 3. FINISH FLOORING TO EXTEND UNDER ALL NEW CASEWORK. 11.FOR FLOOR POWER AND DATA ACCESS 4. PROVIDE A TRANSITION STRIP WHERE EVER TWO DIFFERENT FLOOR MATERIALS MEET a. AT RAISED SLABS:USE WIREMOLD RC7 FLUSH POKE-THRU SERIES OR EQUAL REVISION 5. PROVIDE SCHLUTER METAL TRIM AT ALL EXPOSED EDGES OF TILE(EXCEPT AT BULLNOSED EDGE) b. AT SLAB ON GRADE:USE WIREMOLD RFB4E BOX WITH 6CTC2 COVER AT CONFERENCE ROOMS 09 21 00 GYPSUM BOARD AND 6CFFTC COVER AT FURNITURE FEEDS.PROVIDE 1"CONDUIT FOR POWER AND 2"CONDUIT FOR DATA. GENERAL 12.LOW VOLTAGE SYSTEMS(TELECOMMUNICATION AND DATA)BY FUTURE TENANT. 1 1. ALL GYPSUM BOARD WALLS: ONE LAYER 5/8"TYPE X GYPSUM WALLBOARD,EITHER AT RIGHT ANGLES OR 13.LIGHTING ENERGY MANAGEMENT IS REQUIRED IN ALL BUILDINGS. 2. PARALLEL TO FRAMING ON EACH SIDE OF METAL STUDS SPACED AT 24"O.C. FASTEN WITH 1"TYPES 14.000UPANCY CONTROL DEVICES SHALL BE LEVITON OR WATT STOP. DRYWALL SCREWS 8"O.C.TO VERTICAL EDGES AND 12"O.C.TO TOP AND BOTTOM RUNNERS AND 3 INTERMEDIATE STUDS. STAGGER ALL VERTICAL AND HORIZONTAL JOINTS 24"O.C.(OR ONE STUD SPACING), 15.TEST ALL LIGHTING CONTROL SYSTEMS TO ENSURE THAT CONTROL DEVICES,COMPONENTS,EQUIPMENT EACH SIDE AND OPPOSITE SIDES.. AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND 2. ALL OFFICE GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND TWO FINISH COATS WITH SANDING BETWEEN SPECIFICATIONS. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE 4• FINISH COATS(LEVEL 4 FINISH). PAINT AS INDICATED. IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. 5• 3. ALL OTHER GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND ONE FINISH COAT WITH SANDING AFTER FINISH 16.REMOVE ALL UNUSED DATA AND POWER BOXES AND INFILL WITH GYP BOARD. EXCEPTION-UNUSED DATA COAT(LEVEL 3 FINISH). PAINT AS INDICATED. BOXES UNDER WINDOW SILLS TO REMAIN. ALL BLANK COVER PLATES TO BE BUILDING STANDARD FINISH. 6 4. IN FINISHED SPACES FURR-OUT BUILDING COLUMNS AND EXTERIOR WALLS WITH 5/8"GYPSUM BOARD OVER 17.REMOVE ALL UNUSED LOW VOLTAGE WIRING(TELEPHONE AND DATA)FROM THE RECEPTACLE TO THE METAL STUDS. DISTRIBUTION BOARD.LEAVE PULL STRINGS FROM THE BOX TO THE SPACE ABOVE THE CEILING. A SECTION 7 5. PROVIDE ACOUSTIC GASKETS WHERE WALL INTERSECTS STOREFRONT.QUIETJOINT SHH WHERE WALL OF THE EXISITNG LOW VOLTAGE WIRE MAY BE LEFT IN LIEU OF A PULL STRING MEETS MULLION AND QUIETJOINT SHG WHERE WALL MEETS GLAZING.COLOR SELECTED BY ARCHITECT. OFFICE LIGHTING 8, 6. AT ALL EXISTING WALLS,REMOVE ALL NAILS,SCREWS,FASTENERS,ETC.LEFT BY PREVIOUS TENANT AND 1. OFFICE LIGHT FIXTURES: LITHONIA LED FIXTURE.2BLT240L ADP MVOLT GZ10 LP835, PATCH HOLES READY FOR PAINT. 2. REST ROOM-WALL MOUNTED LIGHT FIXTURE-MARK ARCHITECTURAL LIGHTING SLOT 2 LED,S2LWID 80CRI 7. REPAIR GYPSUM BOARD AT REMOVED ELECTRICAL RECEPTACLES OR DATA BOXES AND FINISH READY FOR 35K 40OLMF 180CRI 135K I60OLMF AS NODIM SCT EGLD MVOLT WHT NS SNS TNS DPL. DRAWN BY: PAINT 3. RECESSED LED DOWN LIGHT: LITHONIA LDN6 35/10 L06 AR LD MVOLT TRW(IP55 LENS) R.M.T. 8. UPON REMOVAL OF WALL BASE, REMOVE RESIDUAL ADHESIVE AND PREP WALL TO PAINT READY CONDITION. 4. OFFICE EGRESS LIGHTING: ISOLITE MINI GENIE SERIES LED VERSION LMIGN NM SQ-CEILING AND WALL WALL CONSTRUCTION MATERIALS MOUNT. SEE PLAN FOR EGRESS PATH.USE OF ISOLITE INVERTER AS ALTERNATE TO BATTERY IS ACCEPTABLE. i. PROVIDE STUDS,TRACKS, BRACING, FASTENING AND OTHER ACCESSORIES NECESSARY FOR COMPLETE INSTALLATION. 5. LIGHT SWITCHES:ACUITY CONTROLS PRE SET ALL PRIVATE OFFICE AND CONFERENCE ROOM SWITCHES TO "VACANCY"AND TO TURN ON AT LAST DIM LEVEL. 2. FRAMING MEMBERS SHALL HAVE THE STRUCTURAL PROPERTIES INDICATED WHERE PHYSICAL STRUCTURAL PROPERTIES ARE NOT INDICATED,THEY SHALL BE AS NECESSARY TO WITHSTAND ALL IMPOSED LIVE LOADS. a. STANDARD WALL SWITCH WITH OCCUPANCY SENSOR-USE WSD DESIGN FRAMING IN ACCORDANCE WITH AISI SG-673. b. WALL SWITCH WITH OCCUPANCY SENSOR AND DIMMING-USE WSXD 3. COLD-FORMED FRAMING SHALL BE GALVANIZED METAL CONFORMING TO ASTM A446/A 446 M GRADE A(33000 c. WALL SWITCH WITH DIMMING AND CEILING MOUNTED OCCUPANCY SENSOR-USE SPOD PSI)G60. WAREHOUSE LIGHTING 4. PROVIDE THE LISTED GYPSUM BOARD PRODUCTS BY U.S.GYPSUM,GEORGIA PACIFIC,NATIONAL GYPSUM OR AN APPROVED EQUAL. 1. LITHONIA LIGHTING LED BAY LIGHTING IBG15L SEF AFL GND(VOLT 40K 80CRI LAOZU DWH. A7 1 5. STANDARD GYPSUM BOARD SHALL BE TYPE'X',5/8"THICK WITH TAPERED EDGES CONFORMING TO ASTM (warehouses below 20') C-36. 2. LITHONIA LIGHTING ELM LT EGRESS LIGHTING. FINISH MATERIALS (FOR BUDGET ONLY) 5EG ALL FINISHES MUST BE SUBMITTED TO PACTRUST PRIOR TO INSTALLATION. CARPET SQUARE TILE: #3082CPT MOHAWK GROUP PTR-CARPET SQUARE "RENEGADE° HEADSTRONG BT354/QB354 MARTIN W. HA358 THRILL SEEKER, FLEXLOK CONNECTORS WALK-OFF CARPET TILE: CLA KAM S, OR ; TUFF STUFF 11 -STEP UP 11 L 1 a ` ' WOC MOHAWK GROUP 983 IRONUSE MOHARE MIR ADGLU VE. M95.0 IN HIGH MOISTURE AREAS " OF O���O (NOTE: FOR PRICING OF ALL MOHAWK PRODUCTS CONTACT: PROJECT �$ 19370 BETH GISH (503) 704-4168 or STEPHEN DELONG (971) 201-0458 3 @ 25' = 100' NOM. 20'-0" BASE RF FLEXCO 4" FLAT RUBBER BASE, 071 BLACK/ BROWN, AT ALL CARPET AREAS. RC FLEXCO 4" &6" COVE RUBBER BASE, 071 BLACK/ BROWN, AT ALL HARD SURFACES. V ---------- ------------------------------ ---------------------- ------ PAINT: Q� PT-1 MILLER 110-4-10 ACRO PURE ULTRA-LOW VOC 0017 LUNA MOON, SATIN LATEX. +-' ♦ PT-2 MILLER 110-4-10 ACRO PURE ULTRA-LOW VOC 0233 DEEP MARSH, SATIN LATEX (ACCENT COLOR) I (AT ALL RESTROOMS USE MILLER 320-5-10 SEMIGLOSS ACRINAMEL) PT-3 MILLER 130-1-05 PERFORMANCE PLUSS- FLAT-MIX IXX79W(WAREHOUSE WALLS) L cPr OFFICE 1 OFFICE LOBBY OFFICE 9 FINISH SCHEDULE o co ,oa qp♦ WALLS CEILINGS RM# NAME FLOOR BASE REMARKS RM# 2O,_On NORTH EAST SOUTH WEST MATERIAL HEIGHT T OFFICE I —---._. -_ -- 100 LOBBY CPT/WOC 4" RF (E) PGWB (E)WW (E) PGWB -- (E)SAT 9'-0" - 100 = d {I 107 , i 101 OPEN OFFICE CPT 4" RF (E) PGWB (E) PGWB (E) PGWB (E) PGWB (E)SAT 9'-0" 101 Q � 102 OFFICE CPT 4" RF (E) PGWB (E)WW-PGWB (E) PGWB (E) PGWB (E)SAT 9'-0" 102 O rn 103 OFFICE CPT 4" RF (E) PGWB (E)WW-PGWB (E) PGWB (E) PGWB (E)SAT 9'-0" - 103 0 0 Lo SECURE EXISTING DOOR O CD LD OFFICE I IN CLOSED POSITION. 104 OFFICE CPT 4n RIF (E) PGWB (E)PGWB (E) PGWB (E) PGWB (E) SAT 9'-0' 104 co r1_ REMOVE HARDWARE - Q (O rZ 104 ---------------- ---- ---------------------- 105 OFFICE CPT 4"RF (E) PGWB (E)PGWB (E) PGWB (E) PGWB (E)SAT 9'-0" - 105 — Z 4 4 �♦ 106 OFFICE CPT 4"RF (E)PGWB (E)WW-PGWB (E)WW-PGWB (E) PGWB (E)SAT 9'-0" - 106 � JQ cj N 107 OFFICE CPT 4" RF (E) PGWB (E)PGWB (E)WW-PGWB (E)PGWB (E)SAT 8'-6" - 107 (CS 00 F co rJ 108 OFFICE CPT 4" RF (E)PGWB (E) PGWB (E)PGWB (E) PGWB (E)SAT V-6" - 108 CO O 0 0 ♦ OFFICE OFFICE 1 _ � a_ LO LO � 1 109 CIRC. CPT 4" RF (E) PGWB (E)PGWB (E)SAT OPEN OFFICEI 110 OFFICE CPT 4" RF (E)PGWB (E)WW-PGWB (E)PGWB (E)PGWB (E)SAT 9'-0" - 110 CONFERENCE I 111 CONFERENCE CPT 4" RF (E)PGWB (E) PGWB (E) PGWB (E)PGWB (E)SAT V-0" - 111 ,24 = OFFICE [;i i i 112 LAN/SERVER (E)VCT 4" RC (E) PGWB (E) PGWB (E) PGWB (E)PGWB (E)SAT 9'-0" 112 O1 los 113 CIRC. CPT 4" RF (E) PGWB -- (E) PGWB (E) PGWB (E)SAT 9'-0" - 113 02 CIRC. ,?I 114 BREAK (E)VCT 4" RC (E) PGWB (E) PGWB (E) PGWB (E) PGWB (E)SAT 9'-0" 114 00 REMOVE I PLYWOOD ram i O 115 CIRC. CPT 4n RF (E ) PGWB (E) PGWB (E) PGWB (E) PGWB (E)SAT 9'-0" -- 115 116 WOMEN (E)SV/CPT 4 RF (E) PGWB (E) PGWB (E) PGWB (E) PGWB (E)SAT 9'-0" 116 ♦ a 25' NOM. 117 MEN (E)SV/CPT 4" RF (E) PGWB (E) PGWB (E) PGWB (E) PGWB (E)SAT V-0" - 117 IE s i 118 TESTING CPT 4" RF (E) PGWB (E) PGWB (E) PGWB (E) PGWB (E)SAT 9'-0" - 118 n/ - -- - WOMEN -- __ _ -- -- - - _- - - - -- 119 IRC. --- --- CPT - 4" RIF _- (E) PGWB E)PGWB - (E)-PGWB — -- (E)SAT 9'-0" --- __ _- _ . 119 LL _---_---__ 120 VEST. CPT 4" RF (E) PGWB (E)PGWB (E)PGWB (E) PGWB (E)SAT 9'-0" - 120 O CIRC. - - - v ♦ 10 121 OFFICE CPT 4" RF (E)PGWB (E)PGWB (E)PGWB (E)PGWB (E)SAT 9'-0" - 121 U O 0 ++s 122 TRAINING CPT 4" RF (E)PGWB (E)PGWB (E)PGWB (E)PGWB (E)SAT 9'-0" - 122 cPr y� CONFERENCE i 123 CIRC. CPT/WOC 4" RF (E)PGWB (E)WW (E)PGWB (E)PGWB (E)SAT 8'-6" - 123 z 0 B ,,1 124 CONFERENCE CPT 4" RF (E) PGWB (E)WW-PGWB (E)WW-PGWB (E)PGWB (E)SAT 9'-0" — 124 O BREAK CIRC. LAN/SERVER � � OFFICE I MEN 114 113 +,z OPEN OFFICE OFFICE 1ze i 125 OPEN OFFICE CPT 4" RF (E) PGWB (E) PGWB (E) PGWB (E)PGWB (E)SAT 8'$" — 125 127 126 OPEN OFFICE CPT 4" RF (E) PGWB (E) PGWB (E)WW-PGWB PGWB (E) SAT 9'-0" - 126 E SV CPT z+' <m OP 127 OFFICE CPT 4" RF (E) PGWB (E)WW-PGWB (E) PGWB (E)PGWB (E)SAT 9'-0" 127 " 128 OFFICE CPT 4" RF (E) PGWB (E)WW-PGWB (E)WW-PGWB (E) PGWB (E)SAT 9'-0" 128 N ♦ A ♦ 129 BREAK (E)VCT 4" RC (E) PGWB (E) PGWB (E) PGWB (E) PGWB (E)SAT 9'-0" - 129 � r I� 60, 130 CIRC. CPT 4" RF (E) PGWB --- (E) PGWB (E) PGWB (E)SAT 9'-0" - 130 W 131 WOMEN (E)SV 6" RC (E) PGWB (E) PGWB (E)PGWB (E) PGWB (E)SAT 9'-0" 131 TESTING OFFICE € i 132 MEN (E)SV 6" RC (E) PGWB (E)PGWB (E)PGWB (E) PGWB (E)SAT 9'-0" -- 132 o ,2, D 133 OFFICE CPT 4" RF (E) PGWB (E)PGWB (E)PGWB (E) PGWB (E)SAT 9'-0" 133 jr Z 134 OFFICE CPT 4" RF (E) PGWB PGWB PGWB (E)WW-PGWB (E)SAT 9'-0" - 134 CIRC. ! RCIRC. OPEN OFFICE 1 136 OPEN OFFICE SC - (E) PGWB (E)PGWB (E)PGWB (E)PGWB (E)SAT 16'-0" - 136 F cn 19 _ U 2E I1 TRAINING REMOVE ISTING SPLIT SYSTEM uj 1 AND EXP D ADJACENT HVAC ZONE Q r NEW 3X9 DOOR TO �x ITEfMATCH EXISTING / )�JJVEST. . �'-0'30 F x 6 RELRE r�n �/) I $ RELOCATE J II DOORAND REMOVE w II FRAME ❑ PLYWOOD OFFICE (jJ OFFII +33 , 134 Z z W II MEN �' � � U III ( 132 - U) U) N II 9 I � W � � wI OPEN OFFICE :D Q Cc 0 ~ 0 I 1 DEMO VCT AND CLEAN/ Z 1 I RE-SEAL FLOOR ' r Q W U � � �- acod Ii 11/1/19 II ��' i , CONSTRUCTION LEGEND PERMIT / CONST EXISTING TO REMAIN REVISION 11 � III ------ EXISTING TO BE REMOVED II 11 it II 2 NEW STANDARD WALL WITH INS. 2. I I ADD HOSE BIB ® p 1 NEW STANDARD WALL WITH INS.TO ROOF STRUCTURE CONSTRUCTION PLAN NOTES: 3' a ELECTRICAL PANEL 4 • NEW PAINT THROUGHOUT OFFICE • PAINT ON NEW WAREHOUSE WALLS ONLY ea FIRE EXTINGUISHER IN RECESSED CAB. 5 • INSTALL BROADLOOM CARPET IN EXISTING CARPETED AREAS ves FIRE EXTINGUISHER-SURFACE MOUNTED 6 • CLEAN WAREHOUSE FLOORING OF ALL GLUES 7. AND FLOORING. NO SEALER. " TUNE POVERHEAD DOORS CEILING LEGEND 8. � PARTITION AND POWER PLAN A-2 SCALE 1/8" 1'-0" Z� � 2X2LED BLTCEILING FIXTURE DRAWN BY: = R.M.T. LED HIGH BAY WAREHOUSE FIXTURE OCCUPANCY SENSOR ON EACH FIXTURE RECESSED LED LIGHT(TYP.) $ STANDARD SWITCH ® OCCUPANCY SWITCH CEILING OCCUPANCY SENSOR A� 2 0 EXIT SIGN(LED RED) #3o8z MARTIN W. HANSONj � CLA KAM S, OREGON,ti 5�; g of o� I I, killPROJECT #19370 311@ 25' = 100' NOM. � 20'-0" U 4--• a ' • ® 1 Q I i I _ O \ I I • R i I � � M R 201-011 `u i Q N Q ti • � i � O rn D' R jj O O l0 - 1 ------------------------ ----------------------- C CMO CngNN co O I— CO (O L'_- LO vv _ _ I 10 I I ' 31 t a 25' NOM. 10C ILM -- 1 >< I I a a W vI Iv IV � G- I t t_s Z _ I Ru/� I - A IQ ww IV u` ) Z r---- r----iI s / U l----iI IL----i L___-i • C`1 (n 0 N W N Z n - Qrn U w o J I—` I �y U) Z LL o It CV acoa 11/1/19 1 0 ; 0 CONSTRUCTION LEGEND PERMIT / CONST L___ a EXISTING TO REMAIN REVISION EXISTING TO BE REMOVED rk a NEW STANDARD WALL WITH INS. 1 m;> CONSTRUCTION CEILING NOTES: p4 NEW STANDARD WALL WITH INS.TO ROOF STRUCTURE 2. 3. • REPLACE DAMAGED OR STAINED TILES AS NEEDED a ELECTRICAL PANEL 4 • INSTALL NEW BLT LED LIGHT FIXTURES • INSTALL NEW LED LIGHTING IN RESTROOMS ea FIRE EXTINGUISHER IN RECESSED CAB. rJ • SERVICE/REPLACE RESTROOM EXHAUST FANS AS NEEDED es FIRE EXTINGUISHER-SURFACE MOUNTED 6. • INSTALL NEW 1500L LED HIGH BAY LIGHTING IN WAREHOUSE 7• REFLECTED CEILING PLANCEILING LEGEND A-3 z 8. SCALE 1/8" = 1'-0" B 2 X 2 LED BLT CEILING FIXTURE DRAWN BY: INDICATES COMMON PATH OF TRAVEL REQUIRING EMERGENCY LIGHTING EQUAL TO 1-FOOT CANDLE FOR A MINIMUM DURATION OF 90 MINUTES. R.M.T. LED HIGH BAY WAREHOUSE FIXTURE OCCUPANCY SENSOR ON EACH FIXTURE RECESSED LED LIGHT(TYP.) STANDARD SWITCH ® OCCUPANCYSWITCH X CEILING OCCUPANCY SENSOR A� 3 0 EXIT SIGN(LED RED)