Plans (35) PLM2018 -00206 BBREVIATIONS VICINITY MAP - A - _--- --- T -__ --- - - - -- -- _ _ bassetti architects LIST OF ARCHITECTURAL ABBREVIATIONS SW SETTLER ST ACC AMBULATORY ACCESSIBLE TOILET COMPARTMENT MAX MAXIMUM ACP ACOUSTICAL CEILING PANEL MDF MEDIUM DENSITY FIBERBOARD 721 NW 9TH Ave, Suite 350 ACT ACOUSTICAL CEILING TILE MDO MEDIUM DENSITY OVERLAY AFF ABOVE FINISH FLOOR MFR MANUFACTURER v Portland, Oregon 97209 ALUM ALUMINUM MIR MIRROR o j T (206) 340 9500 F (206) 340 9519 APPROX APPROXIMATE MISC MISCELLANEOUS m AVE AVENUE MMA METHYL METHACRYLATE `J _J AVG AVERAGE MO MASONRY OPENING Q o `S'� = z AWP ACOUSTICAL STRETCHED FABRIC WALL PANEL MET METAL co p 1:& > CIVIL ENGINEER & LANDSCAPE BCT BABY CHANGING TABLE SURFACE MOUNTED NA NOT APPLICABLE �o y a cn BLDG BUILDING NIC NOT IN CONTRACT Cardno U) GF PROJECT SITE BOT BOTTOM NR NON RATED 00 6720 SW Macadam Ave Suite 200, C AMERICAN STANDARD CHANNEL NTS NOT TO SCALE � Portland, OR 97219 CPT CARPET OC ON CENTER T(503)-419-2500 CG CORNER GUARD OD OUTSIDE DIAMETER CJ CONTROL JOINT OPNG OPENING v,, CL CENTER LINE OPP OPPOSITE SW DURHAM RD �-lQ` STRUCTURAL ENGINEER CMU CONCRETE MASONRY UNIT OZ OUNCE � Catena Engineers COL COLUMN P PAINT CONC CONCRETE PERP PERPENDICULAR w �� 1500 NE Irving Suite 412 CT CERAMIC TILE PL PLATE > � a Portland, OR 9727232 00 T(503)-467-4980 DEPT DEPARTMENT PLAM PLASTIC LAMINATE DF DRINKING FOUNTAIN PLYWD PLYWOOD MECHANICAL ELECTRICAL & DIA DIAMETER PNL PANEL 3 "' S 3: U) PLUMBING ENGINEER DIM DIMENSION PTD PAPER TOWEL DISPENSER W/WAST RECEPTACLE DIM PT DIMENSION POINT PSF POUNDS PER SQUARE FOOT Glumac DN DOWN PSI POUNDS PER SQUARE INCH 1600 DR DOOR RAF RESILIENT ATHLETIC FLOORING SW WAVERLY DR Por nd FifthAve., Suite Portland, OR 97204 DW DISHWASHER RCP REFLECTED CEILING PLAN (503)-227-5280 DWG DRAWING REBAR REINFORCING BAR EA EACH RM ROOM FOOD SERVICE CONSULTANT EL ELEVATION RO ROUGH OPENING LU ELEC ELEC ROW RIGHT OF WAY UJ Webb Foodservice Design ELEV ELEVATOR SCHED SCHEDULE U-1 7 0 Lafayette t. EM ENTRANCE MAT SD SOAP DISPENSER Portland, OR 97202 EQUIP EQUIPMENT SF SQUARE FEET o ���� T(503)-236-8566 EXIST EXISTING SHTG SHEATHING x QO EXT EXTERIOR SIM SIMILAR U G� ACOUSTIC & AV CONSULTANT FA FIRE ALARM SN SANITARY NAPKIN The Greenbusch Group FD FLOOR DRAIN SPEC SPECIFICATIONS g`� 1900 W. Nickerson St., Suite 201 FE FIRE EXTINGUISHER SST STAINLESS STEEL co FEC FIRE EXTINGUISHER CABINET STC SOUND TRANSMISSION CLASS Seattle,WA 98119 T 206-378-0569 FIO FURNISHED AND INSTALLED BY OWNER STD STANDARD FOF FACE OF FINISH SUSP SUSPENDED FOIC FURNISHED BY OWNER INSTALLED BY CONTRACTOR T&G TONGUE AND GROOVE COST CONSULTANT FOM FACE OF MASONRY TLT TOILET FOS FACE OF STUDS TOC TOP OF CURB/TOP OF CONCRETE Construction Focus FRWC FIBER REINFORCED WALL COVERING TPD TOILET PAPER DISPENSER 740 Almaden St. FSP FIXED SOUND ABSORPTIVE PANELS TSCD TOILET SEAT COVER DISPENSER Eugene, OR 97402 FTG FOOTING TWS TACKABLE WALL SURFACE 541-686-2031 GA GAUGE TYP TYPICAL GC GENERAL CONTRACTOR UL UNDERWRITERS LABORATORIES GWB GYPSUM WALL BOARD UNO UNLESS NOTED OTHERWISE GYP GYPSUM UR URINAL TENANT IMPROVEMENTS FOR HDWD HARDWOOD VERT VERTICAL HM HOLLOW METAL VOL VOLUME HORIZ HORIZONTAL WAC WHEEL CHAIR ACCESSIBLE TOILET COMPARTMENT ID INSIDE DIAMETER W/O WITHOUT DECEIVED IN INCHES WAF WOOD ATHLETIC FLOORING INT INTERIOR WC-MB WALL COVERING MARKERBOARD JT JOINT WD WOOD L LENGTH/ANGLE(AS STRUCTURAL SHAPE) WDW WINDOW MDF ROOM RELOCATION R 2 6 2018 LB POUND WT WEIGHT BUILDING DIVISION LF LINEAR FOOT CITY OF TIGARD LINO LINOLEUM LSD LIQUID SOAP DISPENSER LWD LINEAL WOOD CEILING MECHANICAL & ELECTRICAL SCOPE OFFICE COPY GRAPHIC SYMBOLS PROJECT DATA GENERAL NOTES SHEET INDEX CITY OF TIGARD App--- roved.............................. PROJECT ADDRESS: TIGARD HIGH SCHOOL Conditionally Approved.............. [ ] ] 9000 SW DURHAM RD. 1.VERIFY AND COORDINATE SITE CONDITIONS, EXISTING BUILDING CONDITIONS,AND DIMENSIONS. MDF-G0.01 PROJECT INFORMATION See Letter to: Follow.................. [ BUILDING ELEVATION ROOM NAME TIGARD, OR. 97224 BRING INCONSISTENCIES TO ATTENTION OF ARCHITECT BEFORE PROCEEDING WITH WORK. Attached........... .. ROOM NAME M0.00 MECHANICAL LEGEND AND ABBREVIATIONS permit Number: 1,►� ' Qi -FE 61L Elevation ID OWNER TIGARD-TUALATIN SCHOOL DISTRICT 2. IMMEDIATELY BRING INCONSISTENCIES, ERRORS AND OMISSIONS FOUND IN THE DRAWINGS AND 1 M0.02 SCHEDULES Address:,C1dtl0 SCJ: D'kxt�.a.w�. 1219 6960 S.W. SANDBURG ST SPECIFICATIONS TO ATTENTION OF ARCHITECT. TIGARD, OR 97223 M0.03 SCHEDULES A101 Room Number 02 MECHANICAL DETAILS M9 913 3777 503 CATHY KRAUS: ( ) 3. DO NOT SCALE DRAWINGS. COORDINATE DIMENSIONS SHOWN ON DRAWINGS WITH ACTUAL . Sheet Number CONTACT FIELD MEASUREMENTS. NOTIFY ARCHITECT OF DISCREPANCIES. M9.07 MECHANICAL DETAILS ARCHITECT OF RECORD BASSETTI ARCHITECTS MDF.M1 HVAC - MDF PLANS 721 NW 9TH AVE.,#350 4.ALL DIMENSIONS ARE TO FACE OF STUD, FACE OF CONCRETE AND NOMINAL FACE OF MASONRY, BUILDING SECTION SCHEDULE INDICATOR PORTLAND, OR 97209 AND CENTERLINE OF COLUMNS, UNLESS NOTED OTHERWISE. L -Louver CONTACT: CAROLINE LEMAY(503)224 9162 P0.00 PLUMBING LEGEND AND ABBREVIATIONS SW_1 ection ID SF-Storefront 5.WORK INSTALLED IN CONFLICT WITH CONSTRUCTION DOCUMENTS WILL BE CONSIDERED IN MDF.P1 PLUMBING - MDF PLANS 2 W-Window TAX PARCEL NO: 2S114AA00100 NON-CONFORMANCE AND SHALL BE CORRECTED AT NO EXPENSE TO OWNER OR ARCHITECT. A3.21 Sheet Number FP-Fiberglass Sandwich Panel SITE AREA: 43.2 Acres 6. COORDINATION: COORDINATE WORK TO COMPLY WITH DRAWINGS AND SPECIFICATIONS, E0.00 ELECTRICAL LEGEND AND ABBREVIATIONS INCLUDING MECHANICAL, ELECTRICAL, EQUIPMENT AND OTHER CONSTRUCTION. E0.01 ELECTRICAL DRAWING LIST LEGAL DESCRIPTION: SECTION 11, TOWNSHIP 2 SOUTH, RANGE 1 WEST,WILLAMETTE MERIDIAN E0.02 BASIS OF DESIGN AND NOTES P2 RESTORATION KEY NOTE 7. FOLLOW MANUFACTURER'S INSTRUCTIONS, EXCEPT WHERE MORE STRINGENT REQUIREMENTS WALL SECTION ARE INDICATED OR REQUIRED BY CONSTRUCTION DOCUMENTS OR APPLICABLE CODES, E0.03 REFERENCE TABLES ORDINANCES AND REGULATIONS. ED1.12 DEMO PLAN - ELECTRICAL MAIN LEVEL Section ID MATCH LINE E9.04 ELECTRICAL DETAILS 1 _ _ 8. PROVIDE AND INSTALL SOLID BLOCKING OR BACKING FOR ALL WALL AND CEILING MOUNTED E9.06 ELECTRICAL DETAILS A4.11 ITEMS. MDF.E01 BASIS OF DESIGN AND NOTES Sheet Number Location of Adjacent Drawing JURISDICTION: CITY OF TIGARD 9. PROVIDE INTERMEDIATE ROD AND SHELF SUPPORTS FOR SPANS EXCEEDING 36". MDF.E03 MECH & PLUMB EQUIP CONN & LUMINAIRE SCHEDULES FIRE DISTRICT: TUALATIN VALLEY FIRE&RESCUE MDF.E11 ELECTRICAL PLANS - DEMOLITION A REVISIONS DATE DETAIL REFERENCE SEWER DISTRICT: TIGARD SEWER 10. INSTALL OUTLETS, SWITCHES AND OTHER RECESSED ITEMS AT FIRE RATED WALLS IN MDF.E20 ELECTRICAL PLANS - LOWER LEVEL Detail ID DOOR NUMBER WATER DISTRICT: TIGARD WATER ACCORDANCE WITH I.B.C. MDF.E21 ELECTRICAL PLANS - MAIN LEVEL 3 CODES: CITY OF TIGARD MUNICIPAL CODE 11. INSTALL GYPSUM BOARD, OR OTHER SHEATHING OR BACKER BOARD AS SCHEDULED OR MDF.E22 ELECTRICAL PLANS - UPPER LEVEL N A9.04 2014 OREGON STRUCTURAL SPECIALTY CODE(OSSC)* INDICATED, ON BOTH SIDES OF WALL FRAMING UNINTERRUPTED FROM FLOOR TO UNDERSIDE OF MDF.E51 SINFLE-LINE DIAGRAM AND PANEL SCHEDULES 2014 OREGON PLUMBING SPECIALTY CODE(ORSC) FLOOR OR ROOF DECK, UNLESS NOTED OTHERWISE. N N 1 Sheet Number 2014 OREGON MECHANICAL SPECIALTY CODE(OMSC) N 2014 OREGON ENERGY EFFICIENCY SPECIALTY CODE(OEESC) 12.ATTACH PIPING IN SOUND RATED WALLS WITH VIBRATION ISOLATORS. ISOLATE PIPING IN MDF.T1 TECHNOLOGY - MDF PLANS OR 2014 OREGON ELECTRICAL SPECIALTY CODE(OESC) CONTACT WITH CONSTRUCTION. 1 2014 OREGON FIRE CODE(OFC) A101 ICC ANSI A117.1-2009 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES 13. MOUNT ELECTRICAL WIRING DEVICES AND MECHANICAL TEMPERATURE SENSORS AT HEIGHTS S1 El 2010 OREGON SOLAR INSTALLATION SPECIALTY CODE(OSISC) PER SPECIFICATIONS. VERIFY SWITCH, OUTLET AND OTHER DEVICE HEIGHTS TO CLEAR E`) CASEWORK, RADIATORS AND WALL MOUNTED ITEMS, INCLUDING BACK SPLASHES. RECITE NUMBER FF PROPOSED USE: EDUCATIONAL 9TH-12TH GRADE 14. ISOLATE AND OFFSET OUTLETS ONE STUD SPACE MINIMUM AT SOUND RATED WALLS TO R241-2PREVENT SOUND TRANSMISSION. C OCCUPANCY: GROUP E �7 15. COORDINATE SIZES AND LOCATIONS OF OPENINGS AND ROUGH-INS FOR MECHANICAL, TYPE OF CONSTRUCTION: PROPOSED : TYPE II-B&TYPE V-A ELECTRICAL AND OTHER EQUIPMENT WITH RELATED SUB-CONTRACTORS,AND SHOP DRAWINGS EXISTING TYPE II-B&TYPE V-1 HR BUILDINGS EXISTING-TO-REMAIN APPROVED BY THE ARCHITECT, BEFORE PROCEEDING WITH THE WORK. FULLY SPRINKLERED AND FIRE ALARMS 16. VERIFY SIZES AND LOCATIONS OF MECHANICAL AND ELECTRICAL EQUIPMENT PADS, CURBS, TIGARD TUALATIN SCHOOL DISTRICT INTERIOR ELEVATION CASEWORK INDICATOR BASES, POWER,WATER AND DRAIN INSTALLATION WITH EQUIPMENT MANUFACTURERS BEFORE Elevation ID PROCEEDING WITH THE WORK. PROVIDE AND INSTALL SEISMIC BRACING&FASTENING IN TIGARD HIGH 1A ACCORDANCE WITH CODE REQUIREMENTS. 17. COORDINATE EXACT LOCATION OF CONDUIT, PLUMBING AND PIPING WITH ELECTRICAL AND SCHOOL 1D A101 1B MECHANICAL SUBCONTRACTORS. Sheet Number 18. EXIT DOORS: OPERABLE FROM INSIDE BUILDING WITHOUT USE OF KEY OR SPECIAL IVIODERNIZATIO� 1C 211H KNOWLEDGE OR EFFORT. 19. EXIT SIGN LETTERS: SIX INCHES HIGH MINUMUM. CONFORM WITH APPLICABLE CODES. 20. FINISHES: IN FINISHED INTERIOR AREAS: NO EXPOSED PIPE, CONDUITS, DUCTS,VENTS, ETC. GRID LINES N NORTH ARROW UNLESS NOTED OTHERWISE, CONCEAL UTILITY LINES BEHIND FINISHED CONSTRUCTION UNLESS 9000 SW DURHAM RD. NOTED AS EXPOSED CONSTRUCTION ON DRAWINGS OR APPROVED BY ARCHITECT. IF TIGARD, OR. 97224 AFOREMENTIONED WORK CANNOT BE CONCEALED WITHIN FINISHED CONSTRUCTION OF THE A - CONTRACT DOCUMENTS THE CONTRACTOR SHALL PROVIDE&INSTALL FURRED&FINISHED HORIZONTAL&VERTICAL CHASES TO MATCH ADJACENT FINISH TO CONCEAL WORK, COORDINATE JOB NO: 16992.00 WITH ARCHITECT. ISSUE DATE: 4/18/18 21. OFFSET AND ADJUST FRAMING TO MAKE FINISHED SURFACES FLUSH AND TRUE TO LINE. PARTITION INDICATOR EXIT SIGN 22. PROVIDE GALVANIC ISOLATION BETWEEN DISSIMILAR METALS. 23. FIRE EXTINGUISHER CABINETS, EXIT SIGNS, FIRE ALARM AND FIRE PROTECTION SYSTEM COMPONENTS SHALL BE LOCATED IN CONFORMANCE WITH KING COUNTY FIRE DEPARTMENT AND <A31> Partition Type OTHER REGULATORY REQUIREMENTS. FLOOR BOX 24. PROVIDE AND INSTALL FIRE-RESISTIVE JOINT SYSTEMS, FIRE BLOCKS, DRAFT STOPS,AND FIRESTOP SYSTEMS IN ACCORDANCE WITH I.B.C. METAL 25. FIRE PROTECTION: PROVIDE AUTOMATIC FIRE SUPPRESSION SPRINKLER SYSTEM U_ SHELVING THROUGHOUT, IN ACCORDANCE WITH APPLICABLE CODES, REGULATIONS,AND ORDINANCES. Q 26. SPRINKLER SYSTEM TO BE APPROVED BY CITY OF TIGARD FIRE DEPARTMENT AND OTHER REGULATORY AGENCIES PRIOR TO INSTALLATION. OBTAIN ARCHITECT'S APPROVAL OF FIRE PROJECT PROTECTION DRAWINGS PRIOR TO SUBMITTAL FOR FIRE DEPARTMENT REVIEW. 27. RUN FIRE PROTECTION MAIN LINES AND INSPECTOR TEST LINES OUT BEYOND BUILDING LINES. INFORMATION a- DO NOT DRAIN WATER ACROSS SIDEWALK OR OTHER CONCRETE SURFACES. W N �^ M 28. PROVIDE DESIGN BUILD FIRE PROTECTION DRAWINGS AND ENGINEERING AS REQUIRED BY V J CONSTRUCTION DOCUMENTS AND CITY OF TIGARD FIRE DEPARTMENT. F_ in 00 29. COORDINATE INSTALLATION OF FIRE PROTECTION SYSTEM WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL AND OTHER WORK TO ENSURE NO CONFLICT C) AS A RESULT OF FIRE PROTECTION SYSTEM INSTALLATION. MDF-GO - 01 C) w 'IT30. CORNER GUARDS ARE SHOWN ON FINISH PLANS,A-10 SERIES. 31. ELECTRICAL PERMIT AND INSPECTION MUST BE OBTAINED THROUGH OREGON STATE. ABBREVIATIONS HVAC LEGEND NOTE: NOT ALL SYMBOLS ABBREVIATIONS ARE APPLICABLE TO THI HVAC DRAWING LIST PROJECT. REFER TO DETAILS AND NOTES FOR MOUNTING HEIGHTS. AAV AUTOMATIC AIR VENT HWR HEATING WATER PUMP GENERAL VALVES & GAUGES DUCTWORK a .2 assetti ABV ABOVE HWR HEATING WATER RETURN X ISSUED AS PART OF THE DRAWING PACKAGE cc AC AIR CONDITIONING HWS HEATING WATER SUPPLYSYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION • ISSUED FOR REFERENCE ONLY o architects ACCEPT ACCEPTANCE HX HEAT EXCHANGER o oU ACU AIR CONDITIONING UNIT HZ FREQUENCY(HERTZ) AD ACCESS DOOR ID INSIDE DIAMETER NEW WORK BALL VALVESHEET ADD ADDITION IN INCH(ES) AD/AP ACCESS DOOR/ACCESS PANEL NUMBER SHEET NAME a a ¢ a AF AFTER FILTER INPLV INTEGRATED PART LOAD VALUE (E) EXISTING WORK TO REMAIN SOLENOID CONTROL VALVE 721 NW 9TH Ave, Suite 350 AFF ABOVE FINISHED FLOOR JB JUNCTION BOX FLEXIBLE CONNECTION Portland, Oregon 97209 AFMS AIR FLOW MEASURING STATION KW KILOWATT (D) EXISTING WORK TO BE REMOVED PRESSURE AND TEMP. RELIEF VALVE T (206) 340 9500 F (206) 340 9519 AFUE ANNUAL FUEL UTILIZATION EFFICIENCY KWH KILOWATT HOUR M0.00 MECHANICAL LEGEND AND ABBREVIATIONS X X X AG AIR GAP L LENGTH (F) FUTURE WORK ��� BUTTERFLY VALVE M0.1 BASIS OF DESIGN FLEXIBLE DUCT RUNOUT TO DIFFUSER AHJ AUTHORITY HAVING JURISDICTION LAT LEAVING AIR TEMPERATURE MOTORIZED BUTTERFLY VALVE M0.02 SCHEDULES X X41 AHU AIR HANDLING UNIT LBS POUNDS (RL) RELOCATE EXISTING 12x6 RECTANGULAR DUCT SIZE M0.03 SCHEDULES X CIVIL ENGINEER & LANDSCAPE AMB AMBIENT LDB LEAVING DRY BULBCardno A AMPERE LF LINEAR FEET CENTER LINE GATE VALVE (WIDTH x DEPTH IN INCHES) M0.04 SCHEDULES 6720 SW Macadam Ave Suite 200, AP ACCESS PANEL LP LOW PRESSURE 18o ROUND DUCT SIZE DEMO PLANS Portland, OR 97219 BALANCING VALVE MD1.10 DEMO PLAN-HVAC UNDERGROUND X X X T(503)-419-2500 APPROX APPROXIMATELY LPC LOW PRESSURE CONDENSATE POINT OF CONNECTION OR (DIAMETER IN INCHES} ARCH ARCHITECT LPS LOW PRESSURE STEAM POINT OF DISCONNECTION MD1.11 DEMO PLAN-MECHANICAL LOWER LEVEL X • ARI AMERICAN REFIRGERATION INSTITUTE LWB LEAVING WET BULB 1 ANGLE GATE VALVE 2412o OVAL DUCT SIZE MD1.12 DEMO PLAN- MECHANICAL MAIN LEVEL X STRUCTURAL ENGINEER AS AIR SEPARATOR LWT LEAVING WATER TEMPERATURE M-1 DETAIL 1, DRAWING M-1 ^'� WIDTH x DEPTH IN INCHES MD1.13 DEMO PLAN MECHANICAL UPPER LEVEL X Catena Engineers GLOBE VALVE ( ) - 1500 NE Irving St., Suite 412 AUTO AUTOMATIC M MOTOR MD1.14 DEMO PLAN-MECHANICAL ROOF X Portland, OR 97232 AUX AUXILIARY MA MIXED AIR ANGLE GLOBE VALVE MD1.16 DEMO PLAN-MECHANICAL AUDITORIUM PLAN X T(503)-467-4980 B BOILER MAD MIXED AIR DAMPER q DUCT THROUGH BEAM PENETRATION BAS BUILDING MANAGEMENT SYSTEM MAX MAXIMUM M-1 CHECK VALVE COMPOSITE HVAC PLANS MECHANICAL ELECTRICAL & BDD BACKDRAFT DAMPER MBH THOUSAND BTU PER HOUR SECTION A, DRAWING M-1M M1.11 HVAC LOWER LEVEL FLOOR PLAN COMPOSITE PLUMBING ENGINEER BEL BELOW MC MECHANICAL CONTRACTOR ��~ 2-WAY CONTROL VALVEDUCT OFFSET(RISE OR DROP) M1.12 HVAC MAIN LEVEL FLOOR PLAN COMPOSITE Glumac BHP BRAKE HORSEPOWER MCA MINIMUM CIRCUIT AMPACITY M VD RVD M1.13 HVAC UPPER LEVEL SOUTH FLOOR PLAN COMPOSITE 900 SW Fifth Ave., Suite 1600 BOD BOTTOM OF DUCT MCC MOTORIZED CONTROL CENTER 3-WAY CONTROL VALVE VOLUME DAMPER OR REMOTE VOLUME DAMPER M1.14 HVAC UPPER LEVEL NORTH FLOOR PLAN COMPOSITE Portland, OR 97204 BOP BOTTOM OF PIPE MD MOTORIZED DAMPER a���FS M1.15 HVAC ROOF PLAN COMPOSITE T(503)-227-5280 BFP BACKFLOW PREVENTER MECH MECHANICAL 1 NON-SLAM WAFER CHECK VALVE FIRE, SMOKE OR FIRE/SMOKE DAMPER BSMT BASEMENT MERV MINIMUM EFFICIENCY RATING VALUE M-1 ELEVATION 1, DRAWING M-1 ,� NORTH SECTOR HVAC PLANS FOOD SERVICE CONSULTANT BTU BRITISH THERMAL UNIT MFR MANUFACTURER PRESSURE REDUCING VALVE(PRV) SUPPLY DUCT UP M2.13 HVAC MAIN LEVEL-AREA N1 Webb Foodservice Design BTUH BTU PER HOUR MIN MINIMUM EXH v`�' M2.14 HVAC MAIN LEVEL -AREA N2 3700 SE Lafayette Ct. BV BALL VALVE OR BALANCING VALVE MOCP MINIMUM OVER CURRENT PROTECTION DIAPHRAGM VALVE SUPPLY DUCT DOWN M2.15 HVAC UPPER LEVEL-AREA N1 Portland, OR 97202 BYV BUTTERFLY VALVE MPC MEDIUM PRESSURE CONDENSATE 1 RISER IDENTIFICATION T(503)-236-8566 M2.16 HVAC UPPER LEVEL-AREA N2 C COMMON, CONDENSATE OR CONDUIT MPS MEDIUM PRESSURE STEAM EXHAUST#1 EXHAUST DUCT UP LOCK SHIELD VALVE M2.17 HVAC ROOF PLAN-AREA N1 ACOUSTIC &AV CONSULTANT CA CONTROL AIR MV MANUAL AIR VENT Hp CAP CAPACITY (N) NEW 1 EQUIPMENT IDENTIFICATION EXHAUST DUCT DOWN M2.18 HVAC ROOF PLAN-AREA N2 The Greenbusch Group CAV CONSTANT AIR VOLUME N/A NOT APPLICABLE HEAT PUMP UNIT#1 NEEDLE VALVE SOUTH SECTOR HVAC PLANS 1900 W. Nickerson St., Suite 201 CB CHILLED BEAM NC NORMALLY CLOSEDQUICK OPENING VALVE RETURN DUCT UP Seattle,WA 98119 CC COOLING COIL OR CONTROLS CONTRACTOR NIC NOT IN CONTRACT M2.23 HVAC LOWER LEVEL-AREA S1 T 206-378-0569 CEG CEILING EXHAUST GRILLE NO NORMALLY OPEN OR NUMBER KITCHEN EQUIPMENT TAG M2.24 HVAC LOWER LEVEL-AREA S2 # Q VENTURI FLOW METER 8 RETURN DUCT DOWN M2.25 HVAC MAIN LEVEL AREA S1 + UPPER LEVEL AREA S1 COST CONSULTANT O CER CEILING EXHAUST REGISTER NOM NOMINAL CFF CAP FOR FUTURE NPSH NET POSITIVE SUCTION HEAD15o KEYED NOTE CROSS SECTION OF SUPPLY DUCT M2.26 HVAC UPPER LEVEL-AREA S2 Construction Focus CFM CUBIC FEET PER MINUTE NTS NOT TO SCALE PRESSURE GAUGE M2.27 HVAC ROOF PLAN-AREA S1 740 Almaden St. CFS CUBIC FEET PER SECOND OA OUTSIDE AIRo DIRECTION OF TRANSFER AIRFLOW(150 CFM) CROSS SECTION OF EXHAUST AIR DUCT M2.28 HVAC ROOF PLAN-AREA S2 Eugene, OR 97402 CHWP CHILLED WATER PUMP OAD OUTSIDE AIR DAMPER 78 F PRESS. GAUGE WITH COCK AND SNUBBER T 541-686-2031 CHWR CHILLED WATER RETURN OAT OUTSIDE AIR TEMPERATURE 78 DEGREES FAHRENHEIT EAST SECTOR HVAC PLANS CHWS CHILLED WATER SUPPLY OBD OPPOSED BLADE DAMPER PIPING HYDRONIC 0 CROSS SECTION OF RETURN AIR DUCT M2.32 HVAC MAIN LEVEL-AREA E1 CH CHILLER OC ON CENTER CROSS SECTION OF ROUND DUCT M2.33 HVAC ROOF PLAN-AREA E1 CHV CHECK VALVE OD OUTSIDE DAMPER SYMBOL DESCRIPTION SYMBOL DESCRIPTION COMPOSITE ZONING PLANS CL CENTERLINE OFCI OWNER FURNISHED CONTRACTOR INSTALLED > CHWS CHILLED WATER SUPPLY MZ1.11 MECHANICAL SYSTEMS LOWER LEVEL COMPOSITE CLG CEILING OF01 OWNER FURNISHED OWNER INSTALLED DIRECTION OF SLOPE DUCT ELBOW WITH TURNING VANES MZ1.12 MECHANICAL SYSTEMS MAIN LEVEL COMPOSITE CO CLEANOUT OPER OPERATING CHWR CHILLED WATER RETURN MZ1.14 MECHANICAL SYSTEMS UPPER LEVEL NORTH COMPOSITE COL COLUMN OV OUTLET VELOCITY No DIRECTION OF FLOW COMP COMPRESSOR P PUMP OR PRESSURE OR POLE NORTH SECTOR ZONING PLANS HWS HEATING WATER SUPPLY MZ2.13 MECHANICAL MAIN LEVEL-AREA N1 CONC CONCRETE PC PUMPED CONDENSATE 0 PIPE UP(OR UP&DOWN WITH NOTATION) SMOOTH RADIUS DUCT ELBOW WITHOUT TURNING COND CONDENSATE PD PRESSURE DROPHWR HEATING WATER RETURN VANES MZ2.14 MECHANICAL MAIN LEVEL-AREA N2 CONN CONNECTION PF PREFILTER ' PIPE DOWN MZ2.15 MECHANICAL UPPER LEVEL-AREA N1 CONT CONTINUATION PG PIPE GUIDE OR PRESSURE GAUGE CWS CONDENSER WATER SUPPLY MZ2.16 MECHANICAL UPPER LEVEL-AREA N2 CONTR CONTRACTOR PH PHASE(ELECTRICAL) PIPE DROP/PIPE RISE CONICAL BRANCH FITTING SOUTH SECTOR ZONING PLANS COP COEFFICIENT OF PERFORMANCE PHC PREHEAT COIL n CW CONDENSER WATER RETURN MZ2.23 MECHANICAL LOWER LEVEL-AREA S1 CP CONTROL PANEL OR CONDENSATE PUMP PLBG PLUMBING TOP CONNECTION- BRANCH LINE CR CONDENSATE RETURN POC POINT OF CONNECTION CONTROLS 45 DEGREE BOOT LO-LOSS BRANCH FITTING MZ2.24 MECHANICAL LOWER LEVEL-AREA S2 CRG CEILING RETURN GRILLE POD POINT OF DISCONNECTION Y BOTTOM CONNECTION- BRANCH LINE MZ2.25 MECHANICAL MAIN LEVEL AREA S1 + UPPER LEVEL AREA S1 CRR CEILING RETURN REGISTER PRESS PRESSURE SYMBOL DESCRIPTION MZ2.26 MECHANICAL UPPER LEVEL-AREA S2 CSD CEILING SUPPLY DIFFUSER PRV PRESSURE REDUCING VALVE PIPE ANCHOR 12x6 WYE BRANCH FITTING EAST SECTOR ZONING PLANS CTE CONNECT TO EXISTING PS PRESSURE SENSOR TEMPERATURE SENSOR - - - - - - - - - ° © MZ2.32 MECHANICAL MAIN LEVEL-AREA E1 CUFT CUBIC FEET PSI POUNDS PER SQUARE INCH TEE UP ACOUSTICAL LINING DUCT CUIN CUBIC INCHES PSIA PSI ABSOLUTE OT THERMOSTAT OR THERMOMETER (DIMENSION IS INSIDE DIMENSION) COMPSOITE PIPING PLAN CV CONSTANT VOLUME OR CONTROL VALVE PSIG PSI GAUGE V TEE DOWN L M M3 .10 PIPING PLAN UNDERGROUND COMPOSITE X X CW COLD WATER QTY QUANTITY w �° CARBON DIOXIDE SENSOR MOTORIZED DAMPER INSIDE DUCT M3.11 HYDRONIC PIPING PLAN LOWER LEVEL COMPOSITE CWP CONDENSER WATER PUMP R RISERS, RELOCATE OR RISE STRAINER o TAG NECK SIZE-CFM M3.12 HYDRONIC PIPING PLAN MAIN LEVEL COMPOSITE CWR CONDENSER WATER RETURN RA RETURN AIR o ® OCCUPANCY SENSOR �- M3.13 HYDRONIC PIPING UPPER LEVEL SOUTH COMPOSITE CWS CONDENSER WATER SUPPLY RAD RETURN AIR DAMPER STRAINER WITH BLOW OFF z TRANSFER DUCT(WITH LINER) D DROP OR DRAIN RD REFRIGERANT DISCHARGE OR ROOF DRAIN o= HUMIDITY SENSOR OR HUMIDISTAT M3.14 HYDRONIC PIPING PLAN UPPER LEVEL NORTH COMPOSITE 41"_ DBT DRY BULB TEMPERATURE REF ROOFTOP EXHAUST FAN INLINE PUMP ® 8'-11" BOD INDICATES 8'11"TO BOTTOM OF DUCT M3.15 HYDRONIC PIPING ROOF PLAN COMPOSITE DDC DIRECT DIGITAL CONTROL REFRIG REFRIGERATION a STATIC PRESSURE SENSOR NORTH SECTOR PIPING PLAN DEFL DEFLECTION REJ REJECTION BASE MOUNTED PUMP ® M4.13 HYDRONIC PIPING MAIN LEVEL-AREA N1 • DIA DIAMETER REQ'D REQUIRED T REFRIGERANT SENSOR ® TAG NECK SIZE-CFM M4.14 HYDRONIC PIPING MAIN LEVEL-AREA N2 • DIFF DIFFERENCE REV REVISE, REVISION OR REVOLUTIONS TEST TAP(PETE'S PLUG) RECTANGULAR OR ROUND SUPPLY DIFFUSER DN DOWN RF RETURN FAN CARBON MONOXIDE SENSOR OR REGISTER(SEE SCHEDULE).4-WAY THROW M4.15 HYDRONIC PIPING UPPER LEVEL-AREA N1 DP DIFFERENTIAL PRESSURE RH RELATIVE HUMIDITY MANUAL AIR VENT O UNLESS INDICATED OTHERWISE. EXAMPLE: M4.16 HYDRONIC PIPING UPPER LEVEL-AREA N2 DPT DEW POINT TEMPERATURE RHC REHEAT COIL HYDROGEN SENSOR z TAG NECK SIZE-CFM SB12X12-400 REFERS TO TAG SB WITH M4.17 HYDRONIC PIPING ROOF PLAN-AREA N1 DSD DUCT SMOKE DETECTOR RHT RADIANT HEATER r1 AUTOMATIC AIR VENT DSD DUCT SMOKE DETECTOR 12"X12" NECK AND 400 CFM M4.18 HYDRONIC PIPING ROOF PLAN-AREA N2 DV DIAPHRAGM VALVE RM ROOM `� SOUTH SECTOR PIPING PLAN DWG(S) DRAWINGS(S) RPM REVOLUTIONS PER MINUTE VACUUM BREAKER QS zTAG NECK SIZE-CFM RECTANGULAR OR ROUND EXHAUST GRILLE OR M4.23 HYDRONIC PIPING LOWER LEVEL-ARS1 • DX DIRECT EXPANSION RS REFRIGERANT SUCTION J I L TEMPERATURE SENSOR AREA REGISTER(SEE SCHEDULE) (E) EXISTING RTU ROOFTOP UNIT VENT THRU ROOF SP M4.24 HYDRONIC PIPING LOWER LEVEL-AREA S2 • __ EA EXHAUST AIR OR EACH S SUPPLY OR SLOPE STATIC PRESSURE SENSOR TAG NECK SIZE-CFM RECTANGULAR OR ROUND RETURN GRILLE OR M4.25 HYDRONIC PIPING MAIN LEVEL AREA S1 + UPPER LEVEL AREA • EAD EXHAUST AIR DAMPER SA SUPPLY AIR PIPE GUIDE PS REGISTER(SEE SCHEDULE) S1 EAT ENTERING AIR TEMPERATURE SCFM CFM, STANDARD CONDITIONS o DnPS PRESSURE SENSOR OR SWITCH �-- E'er TAG NECK SIZE-CFM M4.26 HYDRONIC PIPING UPPER LEVEL-AREA S2 EC ELECTRICAL CONTRACTOR SD SMOKE DAMPER EXPANSION JOINT o T DIFFERENTIAL PRESSURE SENSOR WALL SUPPLY GRILLE OR REGISTER(SEE SCHEDULE) M4.27 HYDRONIC PIPING ROOF PLAN-AREA S1 ECON ECONOMIZER SEER SEASONAL ENERGY EFFICIENCY RATING w � M4.28 HYDRONIC PIPING ROOF PLAN-AREA S2 DATE EDB ENTERING DRY BULB TEMPERATURE SEN SENSIBLE �I� FLEXIBLE CONNECTOR FMS AIR FLOW MONITORING STATION -. WALL RETURN OR EXHAUST GRILLE OR REGISTER(SE EAST SECTOR PIPING PLAN EWT ENTERING WATER TEMPERATURE SF SUPPLY FAN OR SQUARE FEET O SCHEDULE) M4.32 HYDRONIC PIPING MAIN LEVEL-AREA E1 • EER ENERGY EFFICIENCY RATING SHC SQUARE HEAD COCK T UNION HS TAG NECK SIZE-LENGTH-CFM EF EXHAUST FAN SIU SPLIT INDOOR UNIT FS HUMIDITY SENSOR LINEAR SLOT DIFFUSER(SEE SCHEDULE FOR NUMBER M4.33 HYDRONIC PIPING ROOF PLAN-AREA E1 EFF EFFICIENCY SOU SPLIT OUTDOOR UNIT I CAPPED OR PLUGGED TEE OF SLOTS). 2-WAY THROW UNLESS NOTED M4.41 HYDRONIC PIPING AUDITORIUM-AREA E2 EJ EXPANSION JOINT SP FLOW SENSOR OR SWITCH STATIC PRESSURE � FM - - - - OTHERWISE. EXAMPLES: SN10-48-250 REFERS TO TAG EL ELEVATION SPD SPLITTER DAMPER BLIND FLANGE, CAP z - - - - SN WITH 10" ROUND NECK,48" SLOT LENGTH AND 250 ELEC ELECTRICAL SPEC SPECIFICATIONS CS FLOW METER - - - - CFM. M5.01 MECHANICAL SYSTEM SECTION VIEWS EQUIP EQUIPMENT SQ IN SQUARE INCH CONCENTRIC REDUCER ESP EXTERNAL STATIC PRESSURE ST STRAINER OR SOUND TRAP T C CURRENT SENSOR VARIABLE AIR VOLUME TERMINAL UNIT M6.01 ENLARGED PLANS ET EXPANSION TANK STD STANDARD EXPANSION LOOP M6.02 ENLARGED PLANS EWB ENTERING WET BULB TEMPERATURE STRUCT STRUCTURAL a MOTOR VARIABLE AIR VOLUME TERMINAL UNIT W/REHEAT EXH EXHAUST SV STEAM VENT 6" VALVE ON RISE EXT EXTERNAL T THERMOSTAT OR THERMOMETER HM ACTUATOR M7.01 HEATING WATER PIPING SCHEMATIC DIAGRAM F FAHRENHEIT TCP TEMPERATURE CONTROL PANEL PIPE SIZE(DIAMETER IN INCHES) - - - FAN POWERED TERMINAL UNIT FPB FAN POWERED BOX TDH TOTAL DYNAMIC HEAD RM HYDROGEN MONITOR - - - M8.00 CONTROLS-SCHEMATICS FC FLEXIBLE CONNECTION OR FAIL CLOSED TEMP TEMPERATURE M8.01 CONTROL-SCHEMATICS FCU FAN COIL UNIT TI TENANT IMPROVEMENT Al REFRIGERANT MONITOR M8.02 CONTROL DETAILS TIGARD TUALATIN SCHOOL DISTRICT FD FIRE DAMPER TRG TRANSFER GRILLE AO FAN POWERED TERMINAL UNIT W/REHEAT FF FINAL FILTER OR FINISHED FLOOR TS TEMPERATURE SENSOR DI ANALOG INPUT M8.03 CONTROLS-SEQUENCES OF OPERATION TIGARD H ANALOG OUTPUT FLR FLOOR TSP TOTAL STATIC PRESSURE DO FO FAIL OPEN TT TEST TAP OR TEST TEE BAS DIGITAL INPUT M9.01 MECHANICAL DETAILS X FPI FINS PER INCH TXV THERMAL EXPANSION VALVE PI DIGITAL OUTPUT M9.02 MECHANICAL DETAILS X SCHOOL FPM FEET PER MINUTE (TYP) TYPICAL BUILDING AUTOMATION SYSTEM M9.03 MECHANICAL DETAILS FPS FEET PER SECOND U HEAT TRANSFER COEFFICIENT PULSING INPUT FSD FIRE/SMOKE DAMPER USTEAM C UNDER CUT DOOR M9.04 MECHANICAL DETAILS M9.05MODERNIZATION FT FOOT OR FEET UG UNDERGROUND M9.05 MECHANICAL DETAILS G GAS UH UNIT HEATER SYMBOL DESCRIPTION MISCELLANEOUS M9.06 MECHANICAL DETAILS GA GAUGE, GAGE UON UNLESS OTHERWISE NOTED -HPS HIGH PRESSURE STEAM M9.07 MECHANICAL DETAILS X GAL GALLONS V VENT OR VOLUME OR VELOCITY SYMBOL DESCRIPTION MDF GALV GLAVANIZED VAV VARIABLE AIR VOLUME MPS MEDIUM PRESSURE STEAM RD REFRIGERANT DISCHARGE MDF.M1 HVAC-MDF PLANS X 9000 SW DURHAM RD. GC GAS COCK OR GENERAL CONTRACTOR VB VACUUM BREAKER TIGARD, OR. 97224 GLV GLOBE VALVE BD VOLUME DAMPER LPS LOW PRESSURE STEAM RS REFRIGERANT SUCTION JOB NO: 16992.00 GN GENERAL NOTE VEL VELOCITY GPM GALLONS PER MINUTE VERT VERTICAL HPC HIGH PRESSURE CONDENSATE PNEUMATIC CONTROL VALVE ISSUE DATE: 04/18/2018 GND GROUND VFD VARIABLE FREQUENCY DRIVE GV GATE VALVE VFM VENTURI FLOW METER MPC MEDIUM PRESSURE CONDENSATE ~ AIR LINE Jurisdiction Stamp Area H HEIGHT VOL VOLUME HB HOSE BIBB VTR VENT THROUGH ROOF LPC LOW PRESSURE CONDENSATE POO ST SOUND TRAP HC HEATING COIL W WASTE OR WIDTH OR WATTS _ HD HEAD W/ WITH C PC GRAVITY OR PUMPED CONDENSATE CC COOLING COIL HOR HORIZONTAL W/0 WITHOUT HP HIGH PRESSURE WB WET BULB TEMPERATURE CR CONDENSATE RETURN HC HEATING COIL HP HORSEPOWER WC WATER COLUMN HP HEAT PUMP WEG WALL EXHAUST GRILLE SV STEAM VENT PIPE ® RHT RADIANT HEATER HPC HIGH PRESSURE CONDENSATE WG WATER GAUGE HPS HIGH PRESSURE STEAM WP WORKING PRESSURE STEAM TRAP ® BHT BASEBOARD HEATER HR HOUR(S) WPD WATER PRESSURE DROP MECHANICAL/� HRU HEAT RECOVERY UNIT WRR WALL RETURN REGISTER BBD BOILER BLOW DOWN CB CHILLED BEAM IVI ECI--IAN I CAL HS HUMIDITY SENSOR WSHP WATER-SOURCE HEAT PUMP PI HTR HEATER WSR WALL SUPPLY REGISTER ECCENTRIC REDUCER THRUST BLOCK LL LEGEND AND HV HOSE VALVE WT WEIGHT Q HVAC HEATING, VENTILATING AND AIR CONDITIONING XFMR TRANSFORMER ABBREVIATIONS HW HEATING WATER Z ZONE ZD ZONE DAMPER G W M0 . 00 AIR HANDLING� UNIT SCHEDULE DX COOLINGMEATING WATER _NAL F!' 'TER U E PRE-FILTER R H. P P L Y F ANS H A U ST F A N S HEAINNG WATER,COIL NG RE T RN OX COOL 1, 1 X. %A. i y T�R(A-"� CAFAC�tf bassetti P,D"(FT 1z 0C SINGLE , i PO'V'Iffi- U NIT S Z E VV, �T) I CAPAC�TV architects N M,I t )&A r--;SLP f IN TSP 11N VF_ -A ;o c c R I 1426Y E I LA MAX RD, AiR WfSH) EAT41F) LAT(F) Cf#MPREs SO R� (44 1 S AIRFLUM wNl AIR,FLOW E&F' N 1047 S, Vw`,­ WIx 1-f PE, M ERV NIERV �L NArxH'I iL85) LTS PH PO��`, (Y N) (j (CF` WA,3; yl R11 V E P (YIN') SH6 WIG) I-i P H-P fYJW FAN H EG itmzq� F) (F 7) (F 61k) 711/0 1, N UNIc-1 E-R 1_0GATION A R E A 3 EFRZ V E D �N',) F Nil W(N;p ti, I-,' It D rAv IEER, i (A (A iYPE -4- ......... q�! _q�Z, 0, N AR "13 C: 131 4 t2l,"il 1 3 N_48G N�-4 4,6 ­--------- ----- ---------- ve� p ---------- ------- X "AR I1L- T 1 0 �5 721 NW 9TH Ave, Suite 350 ------ .......... ------------ RT CART 8 3;5 I!G 4 49OX' X7 Portland, Oregon 97209 ----------- 13 x 7_k :4,50-Ci x ER 3 Y, No e, CA, T (206) 340 9500 F (206) 340 9519 1y Or 10 480 AR ' '3 4 A:T No 140 Vil 0: --Y 2' 'N 7 .......... ------------ ----------- __R 2r 2� 2 K't -----­------- ------ CIVIL ENGINEER & LANDSCAPE -F' 2 N 4 t iN 4 Cardno 6720 SW Macadam Ave Suite 200, Portland, OR 97219 T(503)-419-2500 STRUCTURAL ENGINEER a ena ngineers 1500 NE Irving St., Suite 412 Portland, OR 97232 T(503)-467-4980 MECHANICAL ELECTRICAL & PLUMBING ENGINEER Glumac 900 SW Fifth Ave., Suite 1600 Portland, OR 97204 T(503)-227-5280 FOOD SERVICE CONSULTANT Webb Foodservice Design 3700 SE Lafayette Ct. T(503)-236-8566 OUTSIDE AIR'UNIT ` DIX COOLINGMEATIN GO "Al ---------- . ..... ---------­ ------------- ------------ e FE CHANGER _P 1H L TY ING IN EXHAVI'AIR F PE HEATEX DX COOLING H ATER COIL 1900 W. Nickerson St., Suite 201 T: IuVT G Sit GLE OPEJR� -OMPRESSORS 'R C WINT Seattle,WA 98119 i J EMEh ........... T 206-378-0569 FLO DBfWB, CAPACITY FLOW LAT NFI) POWER UNIT SIZE Arf, �ESP "SP- 1E LAI' LPT ESP Ok -Al 01"A MOCP(NISH) F (�-F) 'A' VOLT&;,FIR _Yf I (LBS) 1 P,,D� ARU (A) N WGI, BHI HP (D81WB,PF) (DBPh$E oR j (DPIAM 9F) iD8fVVB 4F) 'OF" (OF) REFRIC, Qrl� 08141 4, N, ATlr "ZE-A SERVED! F KI'A3) CHP _I\jj �4 , , I I TAG A!, Q.P P COST CONSULTANT 4 4' ----------- ---------------- ----------- ....... Construction Focus 740 Almaden St. Eugene, OR 97402 T 541-686-2031 f .......... ' U1 R" ku� i A low Ar N V i, N 'A TR ;f7 4 V R A BY V # DATE F<LV16IUNb ---------- LA ----------P ESP L�A V�D Pavlw ri 0 AFUE EAT OTES -A' N, -,STU;I U M B R Typ� MER T A 'IN Y e 2f�79 TIGARD TUALATIN SCHOOL DISTRICT T TIGARD HIGH SCHOOL MODERNIZATION ............ AIR CONDITIONING CONDENSING UNIT SCHEDULE SPLIT SYSTEM AIR CONDITIONING FAN COIL SCHEDULE 9000 SW DURHAM RD. TIGARD, OR. 97224 ELECTRICAL EMERG OPER. SUPPLY ELECTRICAL INDOOR MANUFACTUR NOM. CAP. REFRIG REFRIG MCA MOCP POWER UNIT SIZE WT. COND AIR OPER. TAG # UNIT TAG ER MODEL LOCATION (TONS) EER SEER TYPE (LBS) VOLTS PH (A) (A) (YIN) (L"ff'xH") (LBS) NOTES UNIT MODEL FLOW CAPACITY MCA UNIT SIZE WT. ISSUE DATE: 04/18/2018 TAG # TAG NUMBER LOCATION TYPE (CFM) (TONS) VOLTS PH (A) MOCP (L"xW"xH") (LBS) NOTES Jurisdiction Stamp Area 7 V T N' x V X N V, X VI; - -- ---------------- t '7 CU 15 FCU-15 DAIKIN RZR36PVJU8 ROOF 3 11.1 17.5 R410A 1.3 208 1 27 30 Yes 300 1-5 f CU 16 FCU-16 DAIKIN ROOF 3 11.1 17.5 R410A 1.3 208 1 27 30 Yes 36xl3x52 300 1-5 FCU 15 CU-15 DAIKIN FBQ36PVJU MDF-El 16 DUCTED CEILING HUNG 1130 3 208 1 3 15 55x28x12 102 2,4 CU 17 FCU-1 7 DAIKIN RZR36PVJU8 ROOF 3 11.1 17.5 R410A 1.3 208 1 27 30 Yes 300 1-5 FCU 16 CU-16 DAIKIN FBQ36PVJU MDF-El 16 DUCTED CEILING HUNG 1130 3 208 1 3 15 55x28x12 102 2,4 FCU 17 CU-17 DAIKIN FBQ36PVJU MDF-El 16 DUCTED CEILING HUNG 1130 3 208 1 3 15 55x28x12 102 2,4 NOTES NOTES MO . 02 1. COORDINATE WITH ELECTRICAL FOR POWER AND DISCONNECT AS REQUIRED. 1. COORDINATE WITH ELECTRICAL FOR POWER AND DISCONNECT AS REQUIRED, OUTDOOR UNIT POWER FEEDS INDOOR UNIT. Uj 2. CAPACITY RATED AT ARI STANDARD CONDITIONS. 2. INTEGRATE WITIH (N) BAS SYSTEM FOR MONITORING AND CONTROL VIA BACNET CARD 3. PROVIDE NEOPRENE MOUNT VIBRATION ISOLATORS(0.5") MOUNTED TO BUILT UP CURB OR STAND. 3. PROVIDE SEPERATE 208/1 VOLT CONDENSATE PUMP(LITTLE GIANT OR EQUIV), 10 FT RISE MIN. ELECTRICAL TO POWER FROM FCU CIRCUIT. 4. PROVIDE LOW AMBIENT KIT FOR OPERATION DOWN TO 10oF. 4. COORDINATE WITH ELECTRICAL FOR POWER AND DISCONNECT AS REQUIRED. SEPERATE INDOOR AND OUTDOOR UNIT CONNECTION. 5. INTEGRATE WITH BAS VIA BACNET CARD 8sisetti architects .sy , > , A1 - 721 NW 9TH Ave, Suite 350 rUNIT Portland, Oregon 97209 SIZE i T (206) 340 9500 F (206) 340 9519 G CIVIL ENGINEER & LANDSCAPE Cardno 6720 SW Macadam Ave , Suite 200. Portland OR 97219 z 0 - 19-2500( ) STRUCTURAL ENGINEER Catena Engineers 1500 NE Irving St., Suite 412 Portland. OR 97232 (503)-467-4980 MECHANICAL ELECTRICAL & _ __ - PLUMBING ENGINEER DIFFUSER AND GRILLE SCHEDULE Glumac 900 SW Fifth Ave., Suite 1600 _ Portland, OR 97204 TAG MANUFACTURER MODEL DESCRIPTION FACE TYPE FACE SIZE COLOR MATERIAL OBD NOTES T(503)-227-5280 NUMBER (INCHES) (NOTE #1) FOOD SERVICE CONSULTANT 7"S B TITUS 272RL AEROBLADE SUPPLY GRILLE 3/4"SPACING, DOUBLE DEFL. SEE PLANS WHITE STEEL YES 2,3,4,5,6 Webb Foodservice Design 3700 SE Lafayette Ct. Portland, OR 97202 T(503)-236-8566 - ACOUSTIC & AV CONSULTANT The Greenbusch Group 1900 W. Nickerson St., Suite 201 Seattle, WA 98119 T 206-378-0569 COST CONSULTANT Construction Focus 740 Almaden St. Eugene, OR 97402 T 541-686-2031 NOTES: 1. MAXIMUM TOTAL PRESSURE DROP SHALL NOT EXCEED 0.15"WG WITH DUCT TRANSITION. 2. MAXIMUM NC LEVEL SHALL BE (20125130). 3. ALL VISIBLE SURFACES AND DUCTWORK BEHIND FACE SHALL BE PAINTED FLAT BLACK. 4. COORDINATE WITH ARCHITECTURAL REFLECTED CEILING PLANS FOR BORDER TYPES. 5. NECK SIZE AND CFM SHOWN ARE ON PLANS (EXAMPLE: SB12x12-400 REFERS TO SUPPLY AIR"S"WITH TAG"B"WITH 12x12 NECK AND 400 CFM). 6. PROVIDE RECTANGULAR/SQUARE TO ROUND TRANSITION AS REQUIRED AND SIZED FOR MAXIMUM 0.01"WG TOTAL PRESSURE DROP. 7. ADJUSTABLE HORIZONTAL/VERTICAL DISCHARGE 8. ANY GRILLE/DIFFUSER MOUNTED DIRECTLY ON EXPOSED DUCT SHALL MATCH COLOR OF DUCT(IF PAINTED) OR SHALL HAVE CLEAR ANODIZED FINISH (IF DUCT IS UNPAINTED). 9. PROVIDE BORDER TYPE (11 /22/xx) (WITH BORDER TYPE 2CRA FOR TWO-SLOT DIFFUSERS). 10. PLENUM CONNECTION SIZE, SLOT LENGTH, AND CFM SHOWN ON PLANS (EXAMPLE: SN8-120-2000 REFERS TO TAG"SN"WITH 8" ROUND CONNECTION, 120" CONTINUOUS SLOT LENGTH AND 2000 CFM). 11. PROVIDE MANUFACTURER'S INSULATED PLENUM. 12. PROVIDE LIGHT SHIELD FOR UNDUCTED SLOT RETURN GRILLES. 13. GRILLE SHALL BE OF ENTIRELY NON-FERROUS CONSTRUCTION FOR MRI IMAGING EQUIPMENT ROOM APPLICATION. WIMF RS0%to'*O'H ED ULF 7" a ..-. F.. _... ..... .. .._. .... .... h.-. .. -. F 01,A1 e ziR2 nw RSL $ P JFK SIVE AmTiPINE 4 t. 7 �. a _ - -4 .: •,�: I i17-11- i 4\ DATE TIGARD TUALATIN SCHOOL DISTRICT _ 777TIGARD HIGH ..,. , .. ... .. .. t , ,,..... ....v _ s k , SCHOOL _ , - . ,..... _.,. ,. .. .. .,, - '.. .' n�",5:+ -.. c, c ,..,<.. ::,..11 ., .. .. _.... 'h: -. -...`:xY a„� ✓ - -, M DERNIZATI N 9000 SW DURHAM RD. TIGARD, OR. 97224 FIRMJOB NO: 16992.00 _ ISSUE DATE: 04/18/2018 Jurisdiction Stamp Area _ : - ,„ a _ — w_ SCHEDULES _ 0_00 r, o W M . 03 a_ Setfil a architects _ 721Ave, Suite 350 Portland, Oregon 97209 T (206) 340 9500 F (206) 340 9519 CIVIL ENGINEER & LANDSCAPE Cardno 6720 SW Macadam Ave Suite 200, Portland, OR 97219 T(503)-419-2500 STRUCTURAL ENGINEER Catena Engineers 1500 NE Irving St., Suite 412 Portland, OR 97232 T(503)-467-4980 MECHANICAL ELECTRICAL & PLUMBING ENGINEER Glumac 900 SW Fifth Ave.. Suite 1600 Portland, OR 97204 T(503)-227-5280 FOOD SERVICE CONSULTANT Webb Foodservice Design 3700 SE Lafayette Ct. Portland. OR 97202 T(503)-236-8566 ACOUSTIC & AV CONSULTANT The Greenbusch Group 1900 W. Nickerson St.. Suite 201 Seattle, WA 98119 T 206-378-0569 COST CONSULTANT Construction Focus DUGT . _ : K� 740 Almaden St. Eugene, OR 97402 T 541-686-2031 c .--I,REl KE texx AIRF0 . { # DATE CONDENSATE PIPING 1" DEFLECTION 3/8" DIA. THREADED ROD(TYP) SPRING FLEX CONNECTION (TYP) VIBRATION _ ISOLATOR(TYP ) T T T 4 IGARD TUALATIN SCHOOL DISTRICT LANCE DAMPER TIGARD HIGH E ' FCU SCHOOL 3 k) MODERNIZATION, RETURN SUPPLY AIR • �� �,�' � - DUCT _ OUTSIDE AIR CONNECTION 9000 SW DURHAM RD. TIGARD, OR. 97224 REFRIGERANT PIPING FILTER WITH SIDE ACCESS JOB NO: 16992.00 ISOLATION VALVES • q ISSUE DATE: 04/18/2018 Jurisdiction Stamp Area CONDENSATE PUMP r EXPIRES: 12/31/19 DPR 0 F F 90 l NOTES: w 1. REFER TO PLANS FOR SIZES AND CONTINUATION. 2. PROVIDE MOISTURE ALARM IN UNIT FOR SECONDARY CONDENSATE PRODUCTION `�ps�Me£R 3. COORDINATE WITH STRUCTURAL DESIGN FOR CEILING ATTACHMENT, 2/M902. 4. LOCATE ISOLATION VALVES IN ACCESSIBLE LOCATION. MECHANICAL U_ DETAILS 0 T FAN COIL-SUSPENDED _ _ - SCALE: NONE75 ry Uj M9 . 02 bassetti architects 721 NW 9TH Ave, Suite 350 Portland, Oregon 97209 T (206) 340 9500 F (206) 340 9519 CIVIL ENGINEER & LANDSCAPE Cardno 6720 SW Macadam Ave Suite 200, Portland, OR 97219 T(503)-419-2500 STRUCTURAL ENGINEER Catena Engineers 1500 NE Irving St., Suite 412 Portland, OR 97232 T(503)-467-4980 MECHANICAL ELECTRICAL & PLUMBING ENGINEER Glumac 900 SW Fifth Ave., Suite 1600 Portland, OR 97204 T(503)-227-5280 FOOD SERVICE CONSULTANT Webb Foodservice Design 3700 SE Lafayette Ct. Portland, OR 97202 T(503)-236-8566 ACOUSTIC &AV CONSULTANT The Greenbusch Group 1900 W. Nickerson St., Suite 201 Seattle,WA 98119 T 206-378-0569 COST CONSULTANT Construction Focus 740 Almaden St. Eugene, OR 97402 T 541-686-2031 #10 SM SCREW,TWO PER BRACKET UNIT SECURED TO PLATFORM WITH 1/4"X3" LAG SCREWS 4"X4"X1/8"ANGLE UNIT TWO PER SIDE 0.5" DEFLECTION 5/8" PLYWOOD NEOPRENE MOUNT WITH 8d AT 6" 24 GAGE GALVANIZED OC SHEET METAL FLASHING EDGE NAILING CAP. NAIL TO CURB 3" HIGH CANT STRIP ALL AROUND FINISHED ROOF 3/8"THRU-BOLT AT EACH CORNER,WITH DOUBLE NUTS, AND MAX 24" SPACING # DATE METAL ROOF 4"X8"(MIN) FIRE RETARDANT TREATED (FRT)WOOD FRAME ALL L3X3X1/4 TWO AROUND. PROVIDE FLUTES INTERMEDIATE LONG(MIN) SUPPORT AT 48"OC AS REQUIRED, NOTES: 1. COORDINATE ANCHORAGE REQUIREMENTS WITH STRUCTURAL DESIGN. CONDENSING UNIT-ROOF MOUNTED 2 SCALE: NONE TIGARD TUALATIN SCHOOL DISTRICT TIGARD HIGH SINK OR SCHOOL LAVATORY MODERNIZATION 9000 SW DURHAM RD. TIGARD, OR. 97224 i JOB N0: 16992.00 3/4"CONDENSATE ISSUE DATE: 04/18/2018 DRAIN. SLOPE DOWN TO SINK Jurisdiction Stamp Area TAILPIECE. EXPIRES: 12/31/19 t� Pr7 � FFffi LAVATORY � G I NeeS 09 TAILPIECE. 90 % aREGON P-TRAP c0 R 3N'� yUA M. GN MECHANICAL NOTES: LL- 1. REFER TO PLANS FOR SIZES AND CONTINUATION C0 G c— G w M9 . 07 - P CONDENSATE CONNECTION TO SINK TAILPIECE Uj 4 SCALE: 1/8" = 1'-0" S13) S14) assetti SHEET NOTES CN - - - - architects A. FINAL REFRIGERANT PIPE SIZES SHALL BE DETERMINED BY SPLIT SYSTEM MANUFACTURER. SUBMIT SHOP DRAWINGS TO TEMPORARILY REROUTE HEATING WATER PIPING. ENGINEERING FOR REVIEW. RECONNECT WITH MAIN TO KEEP SYSTEM 721 NW 9TH Ave, Suite 350 B. REFRIGERANT PIPES SHALL BE HARD BRAZED OR SWEATED (S14)\ __ _ Portland, Oregon 97209 COPPER PIPE. LINE-SETS ARE NOT ACCEPTABLE. `� OPERATIONAL. - _ T (206) 340 9500 F (206) 340 9519 C. PIPE INSULATION SHALL BE CONTINUOUS. DO NOT CUT I I INSULATION FOR SUPPORTS HANGERS. RS/RD DN D. REFRIGERANT DISTRIBUTION BETWEEN CONDENSING UNITS AND FAN COIL UNITS ARE SHOWN AS SINGLE LINE, HOWEVER CIVIL ENGINEER & LANDSCAPE THERE WILL BE(2) PIPES. fCardno E. CONDENSATE SHALL BE EXPOSED COPPER, ROUTED @ 2% I I G`N — — __ — _____ .__. _- __ __ _ __ _—_ __ ______-_ __._ 6720 SW Macadam Ave Suite 200, SLOPE @ 3/4" DIA. SIZE U.O.N RS/RD DN FRSIRD DN I FCU o Portland, OR 97219 F.ALL REFRIGERANT PIPING SHALL BE ROUTED WITH A CLEAN - 16 T(503)-419-2500 FINISH ALUMINUM JACKET G. COORDINATE ROOF PENETRATIONS WITH G.C. MDF STRUCTURAL ENGINEER H.ALL ROOF PENETRATIONS SHALL BE WATER TIGHT, SEE I I E116 Catena Engineers ARCHITECTURAL DRAWINGS A" 00 1500 NE Irving St., Suite 412 I. MDF MECHANICAL COOLING EQUIPMENT SIZED TO MEET 6 TONS `X 2 3/4"CD Portland, OR 97232 WITH N+1 REDUNDANCY OF COOLING BASED ON EQUIPMENT FCU T(503)-467-4980 17 ) 1 11 1 PROVIDED BY THE SCHOOL DISTRICT ON APRIL 11,2018. ' MECHANICAL ELECTRICAL & J. PROVIDE 304 STAINLESS STEEL DRIP PAN BELOW CONDENSATE I I RS/RD PIPING AS IT ROUTES WITHIN MDF I PLUMBING ENGINEER K. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS PRIOR Glumac TO DEMO AND TO NOTIFY ENGINEER OF ANY SUBSTANTIAL 00 X RS/RD 900 SW Fifth Ave., Suite 1600 co FCU Portland, OR 97204 DIFFERENCES IN FIELD I '<, , 15 T(503)-227-5280 00 X FOOD SERVICE CONSULTANT 646X8-1130 Webb Foodservice Design TYP 3) 3700 SE Lafayette Ct. { Portland, OR 97202 RS/RD----,z: I O T(503)-236-8566 ACOUSTIC &AV CONSULTANT KEYED NOTES � �� _ - The Greenbusch Group 1900 W. Nickerson St., Suite 201 1 DECOMMISSION EXISTING MECHANICAL EQUIPMENT I I I Seattle,WA 98119 IN EXISTING MDF ROOM T 206-378-0569 3 2 FOLLOW MANUFACTURER REQUIRMENTS FOR CU CU CU _ CONDENSATE PIPING. ROUTE UP, TYICAL. 17 15 16 COST CONSULTANT 3 TEMPORARILY ROUTE CONDENSATE TO TAIL PIPE OF I I ,; Construction Focus SINK IN WORK ROOM 740 Almaden St. Eugene, OR 97402 T 541-686-2031 HVAC - ROOF - PROPOSED PLAN 3 SCALE: 1/4" = 1'-0" C1 C C3 C iC6 IC8 0 11 'UT o 0 _ T IS 13) _� � =' 0 — - I I HVAC - MDF ROOM - PROPOSED PLAN 2 SCALE: 1/4"= T-0" CF - L R a El - � (v I I I I I I I I — — — — M (3) (514) SD - -- — — — — S E - - - K II ziz� I I c DATE L _ I I J I nKLVIbIUNb DEMO -� �, ]___ �J_� 1 I I o — H ----- -- 1 1 I - DF.MI I` I I 1 - - - - - - - - - - - - - - o 0 0 PROPOSED ROOM � � � ! � ` G _ _ _ _ _ a I TEMPORARILY RELOCATE HEATING SG 1 I I I I - I I — I = 2 �' = - - F I 'X WATER PIPING TO CORRIDOR DF.M , . I I ; r , SH — — — — — — - PROPOSED ROOF E -- ---- -- 3 I V J t� DF.M - — — DLA I I I 1 � ( y DEMO AND I i RELOCATE I I TIGARD TUALATIN SCHOOL DISTRICT ._ SM — — � — — _ _ — I — I — � 11 "�\ RETURN DUCT I I TIGARD HIGH — _ — _ _ BB I I SCHOOL SN 4- I , MODERN IZATION Rill S P — — — — — — — — — — 9000 TIGA DDORH97224AM D. I I ' JOB N0: 16992.00 ISSUE DATE: 04/18/2018 SQ - - - - - - - - - - Jurisdiction Stamp Area I I I I I I I I I I I I I II I 1 ' 14 13 21110 9 8 7 6 5 4 3 2 1 . I �= i I I I I I I I II I I I I I I II HVAC - MDF PLANS 0 S 1 S:S3.2� S5 S6 S7. 18 9.2 IS 1 US 11) IS 1 ZS 14) � 75 75 MAIN FLOOR OVERALL FLOOR PLAN HVAC EXISTING HVAC MDF ROOM DEMOLITION PLAN W M DF . M1 4 SCALE: 1/32"= T-0" SCALE: 1/4" = V-0" OT PLUMBING BASIS OF DESIGN ABBREVIATIONS PLUMBING LEGEND NOTE:APPLICABLE TO THISPRJECT. REFER FIRE PROTECTION TO DETAILS AND NOTES FOR MOUNTING- ARE APPLICABLE TO THIS PROJECT. REFER assetfi ABV ABOVE SYMBOL DESCRIPTION SYMBOL HEIGHTS)ESCRIPTION SYMBOL _ DESCRIPTION architects A. THIS BUILDING DESIGN IS A RENOVATION OF TIGARD HIGH SCHOOL.THE SCHOOL AD ACCESS DOOR TRAP PRIMER 1%SLOPEDIRECTION OF SLOPE F FIRE MAIN ORIGINALLY BUILT IN 1967 HAS BEEN ADDED TO AND MODIFIED MANY TIMES OVER THE ADA AMERICANS WITH DISABILITIES ACT DIRECTION OF FLOW AS AUTOMATIC WET SPRINKLER COURSE OF ITS LIFE. THIS REMODEL WILL REPLACE A LARGE PORTION OF THE AFG ABOVE FINISHED GRADE AFF ABOVE FINISHED FLOOR BALL VALVE 0 PIPE UP OR UP&DN CSP-- COMBINATION STAND PIPE EXISTING STRUCTURE. THE CONSTRUCTION WILL CONSIST OF TWO MAJOR PHASES. AP ACCESS PANEL -0 PIPE DOWN DSP-- DRY STAND PIPE 721 NW 9TH Ave, Suite 350 EXISTING DRAWINGS ARE INCOMPLETE AND CARE SHALL BE TAKEN WHEN ARCH ARCHITECT BUTTERFLY VALVE PIPE DROP Portland, Oregon 97209 INVESTIGATING AND REROUTING UNDERGROUND UTILITIES AS THE EXISTING ASR AUTO FIRE SPRINKLER RISER DOUBLE DETECTOR CHECK VALVE ASSEMBLY T (206) 340 9500 F (206) 340 9519 CONDITIONS ARE LARGELY UNKNOWN. BAS BUILDING AUTOMATION SYSTEM GATE VALVE TOP CONNECTION- BRANCH LINE BFV BUTTERFLY VALVEBOTTOM CONNECTION - BRANCH LINE DOUBLE CHECK VALVE BACKFLOW PREVENTION B. CONTRACTOR IS RESPONSIBLE FOR REVIEWING ALL CONTRACT DOCUMENTS AND BHP BRAKE HORSEPOWER BALANCING VALVE r ASSEMBLY(DC) COORDINATING WITH ALL DISCIPLINES. - - COLD WATER BTU BRITISH THERMAL UNIT CIVIL ENGINEER & LANDSCAPE OS&Y GATE VALVE(OUTSIDE SCREW&YOKE GATE BV BALL VALVE Cardno SHUT OFF VALVE IN CONCRETE YARD BOX - - - - HOT WATER r � C. CODES AND STANDARDS(LATEST EDITIONS UNLESS OTHERWISE REQUIRED BY AHJ) - - - HOT WATER RECIRCULATION VALVE) Car BWV BACKWATER VALVE SW Macadam Ave Suite 200, 1. AMERICANS WITH DISABILITIES ACT(ADA) ANGLE GATE VALVE ------------ VENT TS 'TS Portland, OR 97219 CD CONDENSATE DRAIN 2. OREGON BUILDING CODES ENFORCED BY THE AUTHORITY HAVING JURISDICTION CA COMPRESSED AIR PIPING BELOW GRADE OR FLOOR gi- OS&Y GATE VALVE WITH TAMPER SWITCH T(503)-419-2500 ,�, (AHJ): SOLENOID VALVE PIPING ABOVE GRADE OR FLOOR A) 2014 OREGON STRUCTURAL SPECIALTY CODE(OSSC) BASED ON THE 2012 CR STEAM CONDENSATE RETURN SS SANITARY SEWER,WASTE OR SOIL FDC CFF CAP FOR FUTURE FIRE DEPARTMENT CONNECTION STRUCTURAL ENGINEER tit , INTERNATIONAL BUILDING CODE WITH STATE AMENDMENTS. CFH CUBIC FEET PER HOUR CHECK VALVE SD g STORM DRAIN, RAINWATER DRAIN PIPING Catena Engineers � Qon B) 2,GWOREGON PLUMBING SPECIALTY CODE(OPSC) BASED ON THE 2W a0(5 OD OVERFLOW STORM DRAIN PIPING AUTO FIRE SPRINKLER RISER 1500 NE Irving St., Suite 412 UNIFORM PLUMBING CODE WITH STATE AMENDMENTS. CFM CUBIC FEET PER MINUTE -� PRESSURE REDUCING VALVE PD PUMPED DISCHARGE Portland, OR 97232 C) 2014 OREGON MECHANICAL SPECIALTY CODE(OMSC) BASED ON THE 2012 CFS CUBIC FEET PER SECOND p DRAIN LINE +o FDV FIRE DEPARTMENT VALVE T(503)-467-4980 CI CAST IRON MIXING VALVE IW INDIRECT WASTE INTERNATIONAL MECHANICAL CODE AND THE 2012 INTERNATIONAL FUEL CLG CEILINGMECHANICAL ELECTRICAL & GAS CODE(IMC). CO CLEANOUT , GW GREASE WASTE ® FIRE DEPARTMENT VALVE CABINET PLUMBING ENGINEER D. OUTDOOR DESIGN CONDITIONS(FOR INSULATION AND GAS FIRING CRITERIA): CONC CONCRETE PLUG VALVE/GAS COCK G NATURAL GAS(7"W.C.)MG MEDIUM PRESSURE GAS(2 PSIG TO 5 PSIG) FIRE SPRINKLER FLOOR CONTROL VALVE Glumac 1. WINTER: 22°F CV CHECK VALVE LG LOW PRESSURE GAS 900 SW Fifth Ave., Suite 1600 2. ELEVATION: 500 FT. CW DOMESTIC COLD WATER RELIEF VALVE CA COMPRESSED AIR SIEMESE FIRE DEPT. CONN. Portland, OR 97204 CWFU COLD WATER FIXTURE UNIT T(503)-227-5280 (E) EXISTING PIPE E. WATER SUPPLY: DN DOWN VACUUM RELIEF VALVE TW TEMPERED WATER Off-1 FIRE HOSE VALVE FOOD SERVICE CONSULTANT DCVA DOUBLE CHECK VALVE ASSEMBLY 1. MINIMUM AVAILABLE WATER PRESSURE(STATIC): 100 PSI DDCVA DOUBLE DETECTOR CHECK VALVE TWR TEMPERED WATER RETURN Webb Foodservice Design 2. NORTH CONNECTION ASSEMBLY PRESSURE&TEMPERATURE RELIEF VALVE 6„ FIRE ALARM BELL 3700 SE Lafayette Ct. A) COLD WATER PIPE SIZE: 3 INCHES DFU DRAINAGE FIXTURE UNIT 4 PIPE SIZE(DIAMETER IN INCHES) Portland, OR 97202 3. SOUTH CONNECTION AUTOMATIC AIR VENT (E) EXISTING WORK TO REMAIN T(503)-236-8566 DIA DIAMETER A) COLD WATER PIPE SIZE: 3 INCHES DSN DOWNSPOUT NOZZLE (D) EXISTING WORK TO BE REMOVED 17-PS PRESSURE SWITCH DWG DRAWING BACKWATER VALVE (F) FUTURE WORK FA ACOUSTIC &AV CONSULTANT F. DOMESTIC HOT WATER: DWV DRAINAGE WASTE AND VENT FLOW ALARM The Greenbusch Group 1. SUPPLY TEMPERATURE: 120°F E EXISTING REDUCED- PRESSURE PRINCIPLE BACKFLOW RL RELOCATE EXISTING ( ) FS 1900 W. Nickerson St., Suite 201 2. RECIRCULATION TEMPERATURE: 90°F. ABOVE THIS TEMPERATURE,THE PREVENTION ASSEMBLY(RP) FLOW SWITCH Seattle,WA 98119 RECIRCULATING PUMP WILL BE OFF. ELEC ELECTRICAL FA FLOW ALARM CENTER LINE T 206-378-0569 AS 3. RECIRCULATION TIME: 6:OOAM-8:OOPM. OUTSIDE OF THIS, THE RECIRCULATING FC FLEXIBLE CONNECTION UNION AUTOMATIC WET SPRINKLER RISER PUMP WILL BE OFF. FCO FLOOR CLEANOUT POINT OF CONNECTION OR COST CONSULTANT 4. INCOMING COLD WATER TEMPERATURE: 50°F FDV FIRE DEPARTMENT VALVE STRAINER POINT OF DISCONNECTION ASD Construction Focus 5. WATER HEATER SETPOINT TEMPERATURE: 140°F AUTOMATIC SPRINKLER DRAIN 740 Almaden St. 6. DEMAND PERIOD FOR PEAK SHOWER WATER USAGE: FFE FINISHED FLOOR ELEVATION FDVC FIRE DEPARTMENT VALVE CABINET STRAINER WITH BLOW OFF HOSE BIBB SS SANITARY SEWER STACK Eugene, OR 97402 38 SHOWERS x 8MIN/SHOWER x 30MIN FH FIRE HYDRANT N/Sp FHV FIRE HOSE VALVE T 541-686-2031 PIPE ANCHOR V WET STANDPIPE RISER G. KITCHEN HOT WATER: FIN FINISHED VENT STACKS 1. SUPPLY TEMPERATURE: 140°F FO FUEL OIL PIPE ALIGNMENT GUIDE 2. RECIRCULATION TEMPERATURE: 100°F. ABOVE THIS TEMPERATURE THE FPS FEET PER SECONDPLUMBING DRAWING LIST RECIRCULATING PUMP WILL BE OFF. FT FEET EXPANSION JOINT CW COLD WATER RISER 3. RECIRCULATION TIME: 6:OOAM-5:OOPM. OUTSIDE OF THIS, THE RECIRCULATING FT FLUSH TANK c c PUMP WILL BE OFF. FLEXIBLE CONNECTOR X ISSUED AS PART OF THE DRAWING PACKAGE o FU FIXTURE UNIT HW 4. INCOMING COLD WATER TEMPERATURE: 50°F HOT WATER RISER • ISSUED FOR REFERENCE ONLY a FV FLUSH VALVE o c -c 5. WATER HEATER SETPOINT TEMPERATURE: 160°F G GAS CAP OR PLUG E c m c o 6. KITCHEN DESIGN BY OTHERS GAL GALLONS ( HWC o w o BLIND FLANGE HOT WATER RECIRC. RISER SHEET 1= E W GC GAS COCK E H. SANITARY SEWER: NUMBER SHEET NAME U* GPH GALLONS PER HOUR a a ¢ ¢ ¢ a 1. THE SANITARY SEWER HAS 8 CONNECTIONS TO CIVIL. SEE SHEET P4.02 FOR GPM GALLONS PER MINUTE CONCENTRIC REDUCER G SIZES AND CAPACITIES GV GATE VALVE 4 GAS RISER HD HUB DRAIN I AQUASTAT I. STORM DRAIN: PO.00 PLUMBING LEGEND AND ABBREVIATIONS X X X X X X 1. RAINFALL INTENSITY 1.3 INCHES/HOUR HP HORSEPOWER HW DOMESTIC HOT WATER Q WHA WATER HAMMER ARRESTOR p STORM DRAIN RISER PO.01 SCHEDULES X X X 2. ROOF DRAINS ARE CONNECTED VIA SCUPPERS AND EXTERIOR RAIN LEADERS HWC DOMESTIC HOT WATER RECIRCULATION r PG DEMO PLANS PRESSURE GAUGE WITH COCK LOCATED BY ARCHITECTURAL AND CONNECTED BY CIVIL. HWFU HOT WATER FIXTURE UNIT Op PD1.10 DEMO PLAN-PLUMBING UNDERGROUND X X X X X IAPMO INTERNATIONAL ASSOCIATION OF OVERFLOW DRAIN RISER J. NATURAL GAS SERVICE: T THERMOMETER PD1.11 DEMO PLAN-PLUMBING LOWER LEVEL X • X X • 4 1. GAS PROVIDER: NORTHWEST NATURAL PLUMBING AND MECHANICAL OFFICIALS PD1.12 DEMO PLAN-PLUMBING MAIN LEVEL X • X X 2. EXISTING GAS METERS. ICBO INTERNATIONAL CONFERENCE OF I CONVCO CLEANOUTNVALL CLEANOUT CA I COMPRESSED AIR RISER PD1.13 DEMO PLAN-PLUMBING UPPER LEVEL A) THE EXISTING CERAMICS, MAIN,AND AUTO SHOP METERS WILL BE BUILDING OFFICIALS PD1.14 DEMO PLAN-PLUMBING ROOF X X CONSOLIDATED INTO ONE NEW METER IN PHASE 1 IE INVERT ELEVATION LAV LAVATORY --� FCO FLOOR CLEANOUT )()( COMPOSITE PLANS B) DELIVERY OF MEDIUM PRESSURE GAS: 2 PSI LBS POUNDS(UNIT OF FORCE) X PLUMBING EQUIPMENT P1.10 PLUMBING UNDERGROUND FLOOR PLAN COMPOSITE X X C) MAXIMUM DEMAND: 18,300 CUBIC FEET PER HOUR MAX MAXIMUM -� YCO YARD CLEANOUT P1.11 PLUMBING FLOOR PLAN LOWER LEVEL COMPOSITE • X K. FIRE PROTECTION MBH THOUSANDS BTU/HR �` TT TEST TEE XXX MISCELLANEOUS EQUIPMENT P1.12 PLUMBING FLOOR PLAN MAIN LEVEL COMPOSITE • X 1. THE FIRST PROTECTION SYSTEM IS DESIGN BUILD. MECH MECHANICAL P1.13 PLUMBING FLOOR PLAN UPPER LEVEL SOUTH COMPOSITE X 2. THE SITE CURRENTLY HAS 2 FIRE WATER CONNECTIONS TO THE CITY; (1)4" MFR MANUFACTURERMIN MINIMUM WH WALL HYDRANT P1.14 PLUMBING FLOOR PLAN UPPER LEVEL NORTH COMPOSITE X CONNECTION ON THE EAST SIDE,AND(1)4"CONNECTION ON THE WEST SIDE. MH MANHOLE ® KEYED NOTE P1.15 PLUMBING ROOF PLAN COMPOSITE X 3. THE BUILDING IS SEPARATED INTO 6 ZONES.ZONES 1 AND 2 WIL BE HB HOSE BIBB REVISED WITHINTHE SCOPE OF THE PROJECT. NC NORMALLY CLOSED NFPA NATIONAL FIRE PROTECTION 1 � DETAIL NO. NORTH SECTOR PLANS 4. THE EXISTING WEST CONNECTION WILL BE REVISED TO FEED THE NEW YH YARD HYDRANT P2 SHEET ASSOCIATION NO. P2.11 PLUMBING UNDERGROUND-AREA N1 X X X X CONSTRUCTION AT THE NORTH AND AT THE SOUTH. P2.12 PLUMBING UNDERGROUND-AREA N2 X X X X NO NORMALLY OPEN OR NUMBER THRUST BLOCK # POUNDS OR NUMBER P2.13 PLUMBING MAIN LEVEL-AREA N1 • X • X L. SEISMIC: NIC NOT IN CONTRACT D OFCI OWNER FURNISHED CONTRACTOR P2.14 PLUMBING MAIN LEVEL-AREA N2 • X • X 1. ANCHORAGE AND RESTRAINTS MUST BE COORDINATED WITH STRUCTURAL INSTALLED � � FD FLOOR DRAIN P2.15 PLUMBING UPPER LEVEL-AREA N1 X ENGINEER AND AUTHORITY HAVING JURISDICTION. OW OIL WASTE ® ® ® ® FS FLOOR SINK W/GRATE AS SHOWN P2.16 PLUMBING UPPER LEVEL-AREA N2 X POC POINT OF CONNECTION P2.17 PLUMBING ROOF PLAN-AREA N1 X POD POINT OF DISCONNECTION p0 HUB DRAIN P2.18 PLUMBING ROOF PLAN-AREA N2 X PRV PRESSURE REDUCING VALVE PS PRESSURE SWITCH SOUTH SECTOR PLANS PSI POUNDS PER SQUARE INCH ® ROOF RECEPTOR P2.21 PLUMBING UNDERGROUND-AREA S1 X X X X 2 BP2 ADD#2 4/18/18 RAC ROUGH IN AND CONNECT o STORM DRAIN P2.22 PLUMBING UNDERGROUND-AREA S2 X X X X BP2 ADD#1 04/04/18 RP REDUCED-PRESSURE PRINCIPLE P2.23 PLUMBING LOWER LEVEL-AREA S1 • X X BACKFLOW PREVENTION ASSEMBLY DATE o„ RPM REVOLUTIONS PER MINUTE OVERFLOW DRAIN P2.24 PLUMBING LOWER LEVEL-AREA S2 • X • X KEVIbIUNb SD STORM DRAIN P2.25 PLUMBING MAIN LEVEL AREA S1 + UPPER LEVEL AREA S1 • X • X SF SQUARE FEET DECK DRAIN, PLANTER DRAIN P2.26 PLUMBING UPPER LEVEL -AREA S2 X PHASING SHWR SOLAR HOT WATER RETURN DOWN SPebT NOZZLE P2.27 PLUMBING ROOF PLAN-AREA S1 X SHWS SOLAR HOT WATER SUPPLY P2.28 PLUMBING ROOF PLAN-AREA S2 X SOV SHUT-OFF VALVE EAST SECTOR PLANS SPR SPRINKLER P2.31 PLUMBING UNDERGROUND-AREA E1 X X THE PROJECT PHASING AND ITS IMPACTS TO THE CONSTRUCTION OF THE MECHANICAL, SS SANITARY SEWER ELECTRICAL, PLUMBING, LIGHTING AND LOW VOLTAGE SYSTEMS SHALL BE WHOLLY TP TRAP PRIMER P2.32 PLUMBING MAIN LEVEL-AREA E1 • X OWNED BY THE CM/GC(CONSTRUCTION MANAGER/GENERAL CONTRACTOR)AND THEIR TS TAMPER SWITCH P2.33 PLUMBING ROOF PLAN-AREA E1 X SUB-CONTRACTORS, TEMPORARY FIRE,WATER,SANITARY, STORM, POWER, LIGHTING TT TEST TEE AND CONDITIONING SHALL BE COORDINATED IN CONJUNCTION WITH FINAL DIRECTION TYP TYPICAL FROM THE OWNER, BASED ON THE OWNER'S NEEDS(SAFETY, FUNCTIONALITY, ETC) U URINAL P4.01 WATER/FIRE RISER DIAGRAMS X X DURING THE ACTIVE CONSTRUCTION SCHEDULE. A SEPARATE"PHASING PLAN"SHALL VB VACUUM BREAKER P4.02 WASTE RISER DIAGRAMS X BE CREATED BY THE CM/GC AND INCLUDED AS A PROJECT DOCUMENT. ANY V VENT P4.03 GAS RISER DIAGRAM X REFERENCES TO PHASING OR TEMPORARY SYSTEMS ON THESE DOCUMENTS ARE FOR VTR VENT THROUGH ROOF REFERENCE ONLY AND ARE INTENDED TO AID IN GENERAL COORDINATION BETWEEN W WASTE P6.01 ENLARGED PLAN- KITCHEN X THE DESIGN TEAM AND THE CONTRACTING TEAM. NO SUCH REFERENCES TO PHASING WC WATER CLOSET TIGARD TUALATIN SCHOOL DISTRICT OR TEMPORARY PROVISIONS ON THESE DOCUMENTS THAT ARE IN CONFLICT WITH THE WHA WATER HAMMER ARRESTOR P6.02 ENLARGED PLANS X DETAILS OF THE"PHASING PLAN"DOCUMENT SHALL BE USED AS LEVERAGE FOR WCO WALL CLEANOUT P6.03 ENLARGED PLANS X TIGARD HIGH CHANGER ORDERS DURING CONSTRUCTION." W/ WITH P6.04 ENLARGED PLANS X YB YARD BOX SCHOOL P9.01 PLUMBING DETAILS X X P9.02 PLUMBING DETAILS MODERNIZATIONMDF MDF.P1 PLUMBING-MDF PLANS X Al 0 9000 SW DURHAM RD. TIGARD, OR. 97224 JOB NO: 16992.00 ISSUE DATE: 04/18/2018 Jurisdiction Stamp Area EXPIRES: 06/30/18 PROFFs�� EFS �� 713 i) `' y WEGON� C) 9, PLUMBING LEGEND U_ AND 0 75; ABBREVIATIONS F_ 2 w P0 . 00 �\ 9 AF 14) lassettl architects 721 NW 9TH Ave, Suite 350 Portland, Oregon 97209 ' T (206) 340 9500 F (206) 340 9519 I I 1 I CIVIL ENGINEER & LANDSCAPE CORR REC NNECT TO EXISTING Cardno E100B , 6720 SW Macadam Ave Suite 200, - - —2112°CW - Portland, OR 97219 - - - - -2" HW- - - T(503)-419-2500 - - - - - - - 111HWC- - STRUCTURAL ENGINEER Catena Engineers -- --- ---- - ------ — - - 1500 NE Irving St., Suite 412 Portland, OR 97232 T(503)-467-4980 MECHANICAL ELECTRICAL & I ' PLUMBING ENGINEER Glumac 900 SW Fifth Ave., Suite 1600 Portland, OR 97204 RECONNECT TO EXISTING T(503)-227-5280 I FOOD SERVICE CONSULTANT ' Webb Foodservice Design 3700 SE Lafayette Ct. ' Portland, OR 97202 T(503)-236-8566 I CORR E100 ACOUSTIC & AV CONSULTANT The Greenbusch Group = MDF 1900 W. Nickerson St., Suite 201 E116 Seattle,WA 98119 w O T 206-378-0569 1 COST CONSULTANT N I Construction Focus w 740 Almaden St. Eugene, OR 97402 v T 541-686-2031 N , N 1 ' / 1 1 w SCOPE NOT ASSOCIATED WITH MDF EARLY WORK PACKAGE. - - - - - - . x\ X - - — - o o _ , ENGLISH 1 Jr PREP O O 1 =— 33 244 O D o D o D o O o CEI IOTCHEN D OFF, O O SRO OFFICE 102A °FA°OFFICE - 3 PLUMBING - MDF ROOM - PROPOSED PLAN IACN D56 COOR STUDENT STOP COMMONS N.I. '� 2 CHOIR SCALE: 1/4" = 1'-0" R�`18E ST`i' n` EWORK3 FIT' HEALTH _ _ 00 ;� - - _ MUSIC COMMONS HEAD ACT OFFICE 9 OFFICE U M STORAGEI MUSIC ST21 . _ STORE ° - OFFICE NRC OFFICE RECEPTION 10 LIBRARY _ —_- - -- 21 18 16. 14 11 - 106 `]EAMS GIRLS TEAM 2 (BRCS .-.. _ _ 'J T1 520 ---- PASSAGE RECEP710NIS �• I 100 517 -_ - .. TESTING R STOR? GIRLS TEA41 -- 19 ENSEMBLE ROC - - V SPEC.ED.CR 519 514 _ SE AED MA PRINCIPAL SPEC.ED.CR 120 1� — � INF 15 � Ofes �I OFFICE ASST. 1. LatAULI L 17 15 17 C I S'AFF 510 E S E S : CORR CORR CORK O . r LS PE OF€1�, 'CE 506 511 �. < 38 014K 508 509 '-. VEST., TOILETS FFK: 410 GIRLS PE 505 R BOYS TEAM ROOM SMB 1 KET VARSITY CHEER STOR. E yy 507 WS SOIA 416 MEN 412 OFF.68 BUSINESS LAB ' ENGLISH i� 414 STAFF 1 � JAN WKRM 408 4006 _ I' :.` L SCOPE NOT ASSOCIATED WITH —— OFFICE - I ( CORK MDF EARLY WORK PACKAGE. - BOILER BgLEROFFICE COUNS ...•EN .-_ ,;`__:.._.. .-... --'t..:., _-- E100B —E 418 CAD I COMP.SCI.LAB BUSINESS CLASSROOM SOCIAL STUDIES -400D400 -- g„ 422 608 402 OFFICE 1 ' --- --_--- IN .,` ENGLISH 100E s, OFFICE 1 5 212 I / II 400E 1 _ - __—_—- . . . I ENGLISH OFFICE - -- 224 DATE ONE. -- -- JOURNALISM I — n 42d VIDEO PRODCTION COMP.GRAPHICS - BUS LAB l ACCOUN71 i I - TEACHER WORKROOMSOCIAL STUDIES ENGLISH ——— i ' .--p• I — 426 F L 11 200 I I I I O 1 WMN MEN 210 ENGLISH • F STORAGE I CAREERCENTER �. � _.. MAI M �_ � - CORRIDOR .OHS 1 CORRIDOR I CORR 3 oH5 STOR a CUST o o IA4R o o _ DF.P DEMO ELEV �w ,� ' A.V.ROOM Crl9ST , o I I 400J i — 2W TEXT STOR. OFfiCEO'LE1T TOILE KITCHEN STOR. MATH MATH MATH MATH COMP LAB I! - 206 438 } L—J WORK RM 2 324 323A -_ 202C 202D Ewl oeorKs ART DFP PROPOSED ROOM12 1 ' SHWR LIFE SKILLS �,, 434 20za 202 I REROUTE PIPIES INTO I i 4 TIME I THE CORRIDOR CEILING � I CIRCULATION ..___ E CISH ....200A ST'OR. TOILET TOILET SPACE 549 165 464 d I ,T', TIGARD TUALATIN SCHOOL DISTRICT _ _.. LIBRARY 2466 200L TIGARD HIGH r FlCE -., HEALTH 6C C80 COURTYARD 'I WORKRM. ® � SCHOOL 7 I { STAIR PHYS STOR BUILDING STORAGE STORAGE ELD(ENGLISH LANGUAGE L 119 400X DEVELOPMENT) :_. ST1 �. 1? SCIENCE�TORAGE BUILDING STORAGE I W MODERNIZATION 1 C59 ELEC VESTIBULE,,' __j _� I G L3? I I AUTO EXT.STOR F STORWJVAT�C`N CORR ORAGE • FIRE RISER R c I C STAT " N LOFT OFFICE _ 9000 SW DURHAM RD G61 •-....; - - - ' TIGARD, OR.97224 AUTO SHO CLASSROOM y PREP _ I ' 58 ART J 0 B NO: 16992.00 C56 PHYSICS LAB '. SCIENCE LAB SCIENCE LAB 97 SCIENCE LAB BATHROOM B_ATHROOM FOREIGN LANG ART 334{ 30 -1 322{ 318{ 11? 12? 306{ I ISSUE DATE: 04/18/2018 I I Jurisdiction Stamp Area FOREIGN LANG. it I , I 'CORR I —70 FOREIGN LANG. I 1 IX 1 1 I ENGLISH STORAGE ;'. COMMUNITY PRESCHOOL 818{ MATH 6,2{ T02{ N.I.C, EARLY DAYCARE MATH MATH g9{ PLUMBING - MDF 814{ -. _. -. ___ LL- PLANS 0 N.I.C. " PLUMBING - MDF ROOM - DEMOLITION PLAN ~ CUS - SCHOOL BASED HEALTH " SCHOOL BASED HEALTH CENTER CENTER3 C E72 N.I.C. ET, SCALE: 1/4" = 1'-0" c CHILD DV TO6{LP MDF . P1 ,-- W MAIN FLOOR - OVERALL FLOOR PLAN - PLUMBING - EXISTING 1 SCALE: 1/32" = 1'-0" ELECTRICAL LEGEND NOTE: NOT ALL SYMBOLS OR ABBREVIATIONS ARE APPLICABLE TO THIS ABBREVIATIONS PROJECT. REFER TO DETAILS AND NOTES FOR MOUNTING HEIGHTS. LIGHTING DISTRIBUTION & EQUIPMENT POWER DEVICES REFERENCE SYMBOLS FIRE ALARM SYSTEM (E) EXISTING TO REMAIN IMC THOUSAND CIRCULAR (F) FUTURE KCMIL THOUSAND CIRCULAR MILS � SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION (R) EXISTING TO BE REMOVED KN KEYED NOTE b�YhPs(RL) EXISTING TO BE RELOCATED KO KNOCK OUTRECESSED 2X4 LUMINAIRE BRANCH CIRCUIT PANELBOARDS, SURFACE AND RECESS MOUNTED SIMPLEX RECEPTACLE-WALL, CEILING, ON ALT. xx KEYED NOTE REFERENCE FIRE ALARM CONTROL PANEL AND ASSOCIATED COMPONENTS. AB ABOVE COUNTER BACKSPLASH KW KILOWATTS cts LL _ . - . 7 O FACP PROVIDE 120V POWER AS REQUIRED OR AS INDICATED. ACU AIR CONDITIONING UNIT KVA KILOVOLT-AMPERES SURFACE MOUNTED 2X4 LUMINAIRE MOTOR CONTROL CENTER WITH CODE CLEARANCES SHOWN, DUPLEX RECEPTACLE-WALL, CEILING, ON ALT. BRANCH CIRCUIT OR FEEDER TAG; REFER TO BRANCH CIRCUIT AND - J AC ALTERNATING CURRENT LTG LIGHTING DASHED EQUIP. = FUTURE 125.4 A,AMP AMPERES LCP LIGHTING CONTROL PANEL � RECESSED 1X4 LUMINAIRE FEEDER SCHEDULE FOR WIRE AND CONDUIT SIZES&QUANTITY. Fqq FIRE ALARM ANNUNCIATOR 0 ADJ ADJACENT MAX MAXIMUM DOUBLE DUPLEX RECEPTACLE-WALL, CLG, ON ALT. F AF AMPERE(RATED) FUSE OR CB FRAME MCA MINIMUM CIRCUIT AMPERES 721 NW 9TH Ave, Suite 350 0 SURFACE MOUNTED 1X4 LUMINAIRE TRANSFORMER WITH CODE CLEARANCES SHOWN 1 � FIRE ALARM SYSTEM MANUAL PULL STATION, WALL MOUNTED AFF ABOVE FINISHED FLOOR MCB MAIN CIRCUIT BREAKER J SPECIAL PURPOSE RECEPTACLE-WALL, CEILING ON ALT. POWER; REFER TO DETAIL ON DRAWING INDICATED Portland, Oregon 97209 SERVICE AND/OR DISTRIBUTION EQUIPMENT WITH CODE NEMA CONFIGURATION AS NOTED E4.1 ALARM BELL OR GONG AFG ABOVE FINISHED GRADE MFR MANUFACTURER T (206) 340 9500 F (206) 340 9519 ❑° RECESSED 2X2 LUMINAIRE CLEARANCES SHOWN AHJ AUTHORITY HAVING JURISDICTION MIN MINIMUM M AIC EQUIPMENT SHORT CIRCUIT INTERRUPT MISC MISCELLANEOUS 1-01 SURFACE MOUNTED 2X2 LUMINAIRE RECEPTACLE TYPE SHOWN-WALL-ABOVE COUNTER BACKSPLASH. � STROBE LIGHT-WALL, CEILING MOUNTED RATING(RMS SYM.AMPS) MLO MAIN LUGS ONLY 0 CONNECTION TO MOTOR PROVIDED BY OTHERS AB SEE ARCHITECTURAL DRAWINGS. 2 ELEVATION TAG: REFER TO ELEVATION NUMBER ON DRAWING (#=CANDELA RATING)INDICATED AL ALUMINUM(ALLOY) MO MANUAL OPERATOR E4.1 CIVIL ENGINEER & LANDSCAPE SHADING OF ANY LUMINAIRE INDICATES CONNECTION TO I-04 • CONNECTION TO VARIABLE FREQUENCY DRIVE WITH INTEGRAL SHADED RECEPTACLES NOTED"ON ALT."ABOVE ARE CONNECTED SPEAKER-WALL, CEILING MOUNTED ALTERNATE POWER SOURCE(EMERGENCY, UPS, STANDBY, ETC.) VFD "ON ALT." ALC AUTOMATIC LIGHTING CONTROL MTD MOUNTED AS AMPERE(RATED)SWITCH MTR MOTOR Cardno PER CIRCUITING INDICATED DISCONNECT TO ALTERNATE POWER SOURCE(EMERG., STANDBY, UPS, ETC.) PER 6720 SW Macadam Ave Suite 200, AT CIRCUIT BRKR TRIP SETTING(AMPS) N NEUTRAL(GROUNDED CONDUCTOR) CIRCUITING INDICATED SECTION TAG: REFER TO SECTION NUMBER ON DRAWING COMBINATION SPEAKER/STROBE, WALL MOUNTED Portland, OR 97219 A `n ATS AUTOMATIC TRANSFER SWITCH NC NORMALLY CLOSED 0 SUSPENDED LINEAR LUMINAIRE(SIZE VARIES) DISCONNECT SWITCH, SIZE AS NOTED OR IF NOT SHOWN SIZE PER M 1 INDICATED i (#=CANDELA RATING) AUTO AUTOMATIC NEC NATIONAL ELECTRICAL CODE T(503)-419-2500 CONNECTED MOTOR SIZE AND MOTOR DISCONNECT SCHEDULE DUPLEX RECEPTACLE-WALL-HALF SWITCHED AUX AUXILIARY -,NEG NEGATIVE KITCHEN EQUIPMENT TAG, REFER TO KITCHEN EQUIPMENT rl_J`� HORN-CEILING, WALL MOUNTED STRUCTURAL ENGINEER WALL MOUNTED LINEAR LUMINAIRE(SIZE VARIES) K112 AWG AMERICAN WIRE GAUGE NEMA NATIONAL ELECTRICAL MFGR'S ASSOC. FUSED DISCONNECT SWITCH, SIZE AS NOTED. SIZE FUSE PER � CONTROLLED DUPLEX/DOUBLE DUPLEX RECEPTACLE SCHEDULE BATT BATTERY NL NIGHT LIGHT(UNSWITCHED) 9 Catena Engineers C C SUSPENDED PENDANT LUMINAIRE(SIZE VARIES) I MANUFACTURER'S RECOMMENDATIONS a COMBINATION HORN/STROBE-WALL, CEILING MOUNTED 1500 NE Irvin St., Suite 412 ® CH = � COMBINATION SWITCH/DUPLEX RECEPTACLE MECHANICAL EQUIPMENT IDENTIFICATION TAG (#=CANDELA RATING) BC BARE COPPER NO NORMALLY OPEN Portland, OR 97232 1 ® ENCLOSED CIRCUIT BREAKER DISCONNECT SWITCH, TRIP SIZE AS S BG BELOW GRADE NTS NOT TO SCALE T(503)-467-4980 RECESSED DOWNLIGHT, CEILING MOUNTED BRKR CIRCUIT BREAKER NP NAMEPLATE NOTED. DUPLEX RECEPTACLE-WALL-WITH INTEGRAL GROUND FAULT EQUIP NAME EQUIPMENT BY OTHERS IDENTIFICATION TAG COMBINATION MINI HORN/STROBE-WALL, CEILING MOUNTED(#= C CONDUIT(CIRCULAR RACEWAY) OC ON CENTER SURFACE DOWNLIGHT, CEILING MOUNTED GFI CIRCUIT INTERRUPTER CANDELA RATING) CAB CABINET OD OUTSIDE DIAMETER MECHANICAL ELECTRICAL & DISCONNECT W/MAGNETIC MOTOR STARTER(CONTROLLER)OR PLUMBING ENGINEER CONTACTOR. SIZE PER LOAD SERVED. NEMA SIZE#1 MINIMUM. RECEPTACLE TYPE SHOWN W/WEATHERPROOF COVER AND WIRING A SPRINKLER VALVE TAMPER SWITCH CONNECTION CB CIRCUIT BREAKER OFCI OWNER FURNISHED CONTRACTOR INSTALLED Glumac ® RECESSED WALLWASH Wp CFM CUBIC FEET PER MINUTE OD01 OWNER FURNISHED, OWNER INSTALLED WW DIRECTION-> INTEGRAL GROUND FAULT CIRCUIT INTERRUPTER CKT CIRCUIT OS OCCUPANCY SENSOR 900 SW Fifth Ave., Suite 1600 p SURFACE WALLWASH MAGNETIC MOTOR STARTER(CONTROLLER) OR CONTACTOR. SIZE SYMBOL DESCRIPTION o<> SPRINKLER CEILING P POLE SPRINKLER FLOW SWITCH CONNECTION Portland, OR 97204 WW DIRECTIONS z PER LOAD SERVED. NEMA SIZE#1 MINIMUM. +42" RECEPTACLE TYPE SHOWN AT SPECIAL HEIGHT T(503)-227-5280 NEW WORK LIGHT BEAM TYPE SMOKE DETECTOR(BR=BEAM RECEIVER, CO CONDUIT ONLY PB PUSHBUTTON RECESSED LINEAR WALLWASH CPT CONTROL POWER TRANSFORMER PHO PHASE CONNECTION TO EQUIPMENT PROVIDED BY OTHERS. SHADED=ON WALL MOUNTED ELECTRICAL CONNECTION TO ELECTRIFIED BR , BT BT=BEAM TRANSMITTER) FOOD SERVICE CONSULTANT ® J — — — — WIRING CONCEALED IN FLOOR OR UNDER GRADE CT CURRENT TRANSFORMER PNL PANEL Design SURFACE LINEAR WALLWASH ALT. POWER SOURCE NOTED FURNITURE. PROVIDE 8 WIRES(4 HOTS, 1 DEDICATED NEUTRAL, 1 Webb Foodservice Desi COMMON NEUTRAL, 1 IG NEUTRALS TO BE#10 AWG. USE LIQUID- OR ROUTED IN CEILING SPACE OF FLOOR BELOW. SMOKE DETECTOR, DUCT MOUNTED, WITH FULL WIDTH SAMPLING CU COPPER +,POS POSITIVE 3700 SE Lafayette Ct. DC DIRECT CURRENT PRI PRIMARY CONNECTION TO EQUIPMENT WITH INTEGRAL DISCONNECT TIGHT FLEX. TUBES. PHOTOELECTRIC TYPE UON. Portland, OR 97202 RECESSED WALL MOUNTED LUMINAIRE EPEXISTING WORK TO REMAIN PROVIDED BY OTHERS. SHADED= ON ALTERNATE POWER SOURCE (E) DISC DISCONNECT REQD REQUIRED T(503)-236-8566 NOTED CLOCK HANGER RECEPTACLE SMOKE DETECTOR, LOW AIR VELOCITY IN DUCT MOUNTED DIA DIAMETER RNC RIGID NON-METALLIC CONDUIT(PVC) T7 TRACK LIGHTING WITH HEADS AS INDICATED. p EXISTING WORK TO BE REMOVEDIV DIVISION RS RAPID START �1----a- ( ) p PHOTOELECTRIC TYPE U.O.N.UONDP DISTRIBUTION PANEL RST REMOTE STATION TRANSMITTER ACOUSTIC &AV CONSULTANT EQUIPMENT OR TERMINAL ENCLOSURE AS NOTED, SURFACE AND FLUSH FLOOR BOX DEVICE-DEVICE TYPE PER SYMBOLS ABOVE The Greenbusch Group RECESSED CEILING ADJUSTABLE POINT SOURCE J Q F FUTURE WORK DPDT DOUBLE POLE DOUBLE THROW SAD SEE ARCHITECTURAL DRAWINGS p RECESS MOUNTED ( ) SMOKE DETECTOR-WALL, CEILING MOUNTED(P=PLENUM DPST DOUBLE POLE SINGLE THROW SEC SECONDARY '� � 1900 W. Nickerson St., Suite 201 pa SURFACE CEILING ADJUSTABLE POINT SOURCE DM PEDESTAL FLOOR DEVICE-DEVICE TYPE PER SYMBOLS ABOVE p,B,R MOUNTED, B=W/RELAY BASE, R=ELEVATOR RECALL, C=INTEGRAL DWG DRAWING SN SHEET NOTE Seattle,WA 98119 DAMPER MOTOR T TELEPHONE SYSTEM CONDUIT TO DOOR CLOSURE) T 206-378-0569 POKE THRU UNIT WITH DUPLEX RECEPTACLE- FLUSH, PEDESTAL E,EMER EMERGENCY SOL SOLENOID Q WALL MOUNTED LUMINAIRE O O MOUNTED. MV MEDIUM VOLTAGE CONDUIT 7 EF EXHAUST FAN SPD SURGE PROTECTION DEVICE SMOKE DETECTOR MOUNTED BELOW RAISED FLOOR EMT ELECTRICAL METALLIC TUBING SPDT SINGLE POLE DOUBLE THROW COST CONSULTANT F WALL MOUNTED DIRECTIONAL(SIZE VARIES) - BUSWAY RISER ENCL ENCLOSURE SPST SINGLE POLE SINGLE THROW Construction Focus PEDESTAL MOUNTED. POKE THRU UNIT WITH DOUBLE DUPLEX RECEPTACLE-FLUSH, G BARE GROUNDING GRID OR CONDUCTORS, UON. ELECTROMAGNETIC DOOR HOLDER-WALL, FLOOR, DOOR CLOSURE @EO ELECTRICALLY OPERATED SUB SUBSTATION 740 Almaden St. ® ® ® � FLUORESCENT STRIPLIGHT-POWER FEED SECTION, FEED GROUNDING CONDUCTORS ROUTED IN CODE SIZED CONDUIT, UON. C MOUNTED. COORDINATE WITH DOOR INSTALLER. EOL END OF LINE SWBD SWITCHBOARD Eugene, OR 97402 THROUGH SECTION. LENGTH AS SHOWN. BUSWAY STAB-IN TYPE CIRCUIT BREAKER OR FUSE DISCONNECT. GC ( ) EWC ELECTRIC WATER COOLER SWGR SWITCHGEAR T 541-686-2031 SIZE AS NOTED. COMBO POKE THRU UNIT WITH DUPLEX RECEPTACLE AND DATA LOOP ISOLATION MODULE ® m ® m TELEPHONE OUTLET-FLUSH, PEDESTAL MOUNTED. STROKES INDICATE QUANTITY OF#12 AWG. CONDUCTORS, UON. LM EWH ELECTRIC WATER HEATER TB TERMINAL BOARD WALL MOUNTED FLUORESCENT STRIPLIGHT � NOTE: WIRING STROKES FOR 20A BRANCH CIRCUITS ARE NOT FA FIRE ALARM TDC TIME DELAY CLOSING I DIAGRAMS CM ADDRESSABLE CONTROL MODULE MULTI-SERVICE FLOOR BOX CAST IN CONC. OR IN RAISED FLOOR- SHOWN ON DRAWINGS. CONTRACTOR SHALL USE INFORMATION IN FAA FIRE ALARM ANNUNCIATOR TDO TIME DELAY OPENING UNDERCABINET FLUORESCENT STRIPLIGHT PANEL AND BRANCH CIRCUIT SCHEDULES TO PROVIDE REQUIRED FACP FIRE ALARM CONTROL PANEL TEL TELEPHONE SEE ARCH DWGS; WITH RECEPTACLES&SIGNAL OUTLETS AS MM ADDRESSABLE MONITOR MODULE SYMBOL DESCRIPTION NOTED. CIRCUITING. FBO FURNISHED BY OTHERS TYP TYPICAL CONTINUOUS LINEAR SOURCE(LED, COLD CATHODE, NEON, FIBER EOL FC FOOT CANDLES OF UNDERFLOOR END OF LINE RESISTOR(MAY NOT BE SHOWN ON PLANS) OPTIC, ETC...) o AUTOMATIC TRANSFER SWITCH(ATS) POKE THRU UNIT WITH JUNCTION BOX. RACEWAY COMPONENTS RC- GROUND FF FLUSH FLOOR MOUNTED UG UNDERGROUND BATTERY POWER EMERGENCY UNIT EQUIPMENT(SEE LUMINAIRE ® 700 SERIES. FIREMAN'S PHONE JACK, WALL MOUNTED FLA FLEX FULL LOAD AMPERES UL UNLESS UNDERWRITERS OTHERWISE NOTED HOT I" of SCHEDULE FOR QUANTITY OF HEADS)-WALL, CEILING MOUNTED. o� AUTOMATIC TRANSFER SWITCH WITH MAINTENANCE BYPASS TELE/POWER POLE, POWER POLE J FIREMAN'S PHONE HANDSET,WALL MOUNTED FPB FAN POWERED BOX UPS UNINTERRUPTIBLE POWER SUPPLY (BIATS) @ NEUTRAL FSD FIRE/SMOKE DAMPER UTX UTILITY TRANSFORMER ® ILLUMINATED EXIT SIGN, SHADED QUADRANT INDICATES FACES, P FW FLUSH WALL MOUNTED V VOLTS FIRE/SMOKE DAMPER BY DIV 15. WIDTH OF SYMBOL WILL VARY ARROWS AS SHOWN OVERLOADSHOME RUN WIRING TO INDICATED DESTINATION, 3/4"C. MIN. OR AS FU FUSE VA VOLT-AMPERES J TELE/POWER POLE WITH WHIP CONNECTION TO ELECTRIFIED �--� ® WITH DUCT WIDTH. PROVIDE POWER AND MONITORING AS J FURNITURE L1A-1,3 OTHERWISE NOTED.CONTRACTOR SHALL USE CIRCUIT SIZES ® INDICATED. REFER TO FSD CONNECTION DETAIL. GEN GENERATOR VFD VARIABLE FREQUENCY DRIVE 0 BOLLARD � NORMALLY CLOSED CONTACTOR OR RELAY CONTACTS - - NOTED IN RESPECTIVE SCHEDULES AND INFORMATION IN THE GFI GROUND FAULT CIRCUIT INTERRUPTER W WATT TWO-PIECE SURFACE METAL RACEWAY WITH RECEPTACLES AS FEEDER AND BRANCH CIRCUIT SCHEDULES. FLAME DETECTOR(FLICKER DETECTOR) G,GND GROUND W/ WITH POLE MOUNTED LUMINAIRE-SINGLE OR DUAL HEAD NORMALLY OPEN CONTACTOR OR RELAY CONTACTS@ GRAP GENERATOR REMOTE ANNUNCIATOR PANEL W/O WITHOUT NOTED, BACK LENGTH AS INDICATED ON THE DRAWINGS AND WITH ALL FITTINGS AS REQUIRED. HD1A „ CONDUIT RUN TURNED UP THROUGH FLOOR OR CEILING. CORE& HEAT DETECTOR CEILING MOUNTED. RATE OF RISE AND FIXED GRC GALVANIZED RIGID STEEL CONDUIT WP WEATHERPROOF INDICATES ROTATED OPTICS BUS DUCT FIREPROOF AS REQUIRED. ® TEMPERATURE TYPE, UON. HLO HANDLE LOCK-ON(OFF) XFR TRANSFORMER HP HORSEPOWER XP EXPLOSION PROOF(P V TWO OR THREE COMPARTMENT SURFACE METAL RACEWAY WITH POST TOP MOUNTED LUMINAIRE BUS BAR J CONDUIT RUN TURNED DOWN THROUGH FLOOR OR CEILING. CORE& HPF HIGH POWER FACTOR Z ZONE ® RECEPTACLES AND OUTLETS AS INDICATED, LENGTH AS INDICATED ° ® HEAT DETECTOR(R/C=RATE OF COMBUSTION, F=FIXED TEMP. HTR HEATER ",IN INCHES IN-GRADE POINT SOURCE BATTERY GENERAL ON THE DRAWINGS. PROVIDE ALL FITTINGS AS REQUIRED. FIREPROOF AS REQUIRED. R/C,F,R ONLY, R=RATE OF RISE ONLY) HZ HERTZ(CYCLES PER SECOND) ',FT FEET ��I� TX REMOTE MOUNTED LINE TO LOW-VOLTAGE FUSED TRANSFORMER. CONDUIT STUBBED OUT AT LOCATION SHOWN. EARLY WARNING SMOKE DETECTION SYSTEM-INCLUDES ALL IES ILLUMINATING ENGINEERING SOCIETY 0 PHASE GARAGE LIGHTING LUMINAIRE WITH CUTOFF LOUVERS RESISTOR CONCEAL FROM VIEW. PROVIDE INSULATED BUSHING&PULLROPE. ® SAMPLING TUBING IBC INDIVIDUAL BRANCH CIRCUIT > GREATER THAN ID INSIDE DIAMETER < LESS THAN LUMINAIRE MARKING CONVENTION LEGEND: -�� CONNECTOR, FEMALE AND MALE RESPECTIVELY F TELEPHONE/DATA SLEEVE THROUGH WALL, ABOVE CEILING. LIGHT(LAMP, SIGNAL LIGHT, INDICATOR LAMP, STROBE) IG ISOLATED GROUND > GREATER THAN OR EQUAL TO HA HA= LUMINAIRE TYPE IDENTIFICATION. SEE LUMINAIRE EXTEND TO ACCESSIBLE TILE CLG. BOTH SIDES. TERMINATE WITH ° �o SCHEDULE. PIPE GROUND SIGNAL DEVICES BUSHINGS.(1) 1.25"CO UON. COORDINATE LOCATIONS WITH CABLE FIRE ALARM OUTPUT OR RELEASE ABORT PUSHBUTTON, REFER TO 3c 3c=CIRCUIT NUMBER VIA LOCAL SWITCH(LOWERCASE INSTALLER(S)PRIOR TO ROUGH-IN. , SPECIFICATIONS AND DETAILS. HA LETTER)THAT SERVES THE LUMINIARE. O CONTACTOR COIL SYMBOL DESCRIPTION 3A=CIRCUIT NUMBER/UPPERCASE LETTER COMBINATION ® BASKET TYPE CABLE TRAY WITH 90 DEGREE ELBOW SHOWN INDICATES LOW VOLTAGE RELAY OR LIGHTING R W a AGENT RELEASE INITIATING VALVE 3A O RELAY COIL TERMINAUMOUNTING BOARD, 8 HIGH, 3/4 x4'x WIDTH AS SHOWN, CONTACTOR THAT SERVES THE LUMINAIRE FIRE RETARDANT TREATED PLYWOOD. LADDER TYPE CABLE TRAY WITH 90 DEGREE ELBOW SHOWN N , � LIGHTNING SURGE ARRESTOR D= DISTRIBUTION CLASS BELL SILENCE SWITCH D I = INTERMEDIATE CLASS SIGNAL SYSTEM EQUIPMENT ENCLOSURES AS NOTED-SURFACE, �O � JUNCTION BOXES,WALL, CEILING AND FLUSH FLOOR MOUNTED. 4° AGENT DISCHARGE SWITCH SWITCHING CONTROLS SURGE PROTECTION DEVICE RECESSED MOUNTED SQ. BOX MIN., LARGER IF REQUIRED SPD SYMBOL DESCRIPTION WIRING EXTENSION POINT-CONDUIT TO MC CABLE OR CURRENT TRANSFORMER 11 COMBO TELEPHONE/DATA OUTLET-WALL MANUFACTURED WIRING SYSTEM J-BOX ABOVE ACCESSIBLE Sa SINGLE POLE SWITCH(SUPERSCRIPT DENOTES SIMILARLY MARKED X X INDICATES QUANTITY OF CABLE/JACKS ® ® CEILINGS AREAS, OR EXTEND CONDUIT&WIRE IN EXPOSED OR LUMINAIRES CONTROLLED TOGETHER) POTENTIAL TRANSFORMER "HARD"CEILING AREAS. SHADED=ON ALT. POWER SOURCE SECURITY SYSTEM 10 ® TELEPHONE OUTLET-WALL, W= USE HIGHER MOUNTING HEIGHT (EMERG,UPS,ETC.) S2 TWO POLE SWITCH L NORMALLY OPEN PUSH BUTTON X W PER MOUNTING HEIGHT DETAIL SYMBOL DESCRIPTION X INDICATES QUANTITY OF CABLE/JACKS FP B] PULL BOX, MIN. SIZE PER NEC., UON. S3 THREE WAY SWITCH -L NORMALLY CLOSED PUSH BUTTON S4 FOUR WAY SWITCH �° FUSED VOLTAGE SENSE LEADS X DATA OATLE QUANTITY OF CABLE/JACKS �R�= UNDERFLOOR RACEWAY j ACP ACCESS CONTROL PANEL(S) - --- --- `��f FLEXIBLE CONDUIT CONNECTION SK KEY OPERATED SWITCH pF METER: POWER FACTOR RF COAX CABLE OUTLET PS-X ELECTRIFIED PANIC HARDWARE POWER SUPPLY DATE ® POWER CONNECTION TO DIV 15 FIRE/SMOKE DAMPER. REFER TO D DIMMER SWITCH. NUMBER INDICATES WATTAGE RATING, IF NOT COMBINATION RF COAX CABLE AND DATA OUTLET ® FSD CONNECTION DETAIL IF NOT SHOWN SHOWN THEN EQUAL TO LOAD. KW METER: KILOWATT HOUR AUDIO LOUDSPEAKER-WALL, CEILING, X=WIRING ZONE CR CARD READER-WALL MOUNTED ® DIMMER SWITCH UNDER SEPARATE COVERPLATE M M UTILITY CO.APPROVED SOCKET WITH METER INSTALLED. S X O GROUNDING SYSTEM O EL SP SWITCH WITH PILOT LIGHT(PILOT IS"ON WHEN SWITCH IS"ON"). SQUARE=REMOTE MOUNTED V VOLUME CONTROL-WALL SYMBOL DESCRIPTION ELECTRIFIED LOCK HARDWARE DMU DIGITAL METER UNIT. REFER TO SPECIFICATIONS. g BELL SPS SWITCH WITH PILOT LIGHT(PILOT IS"ON WHEN SWITCH IS"OFF'). G BARE GROUNDING GRID OR CONDUCTORS, UON. ES ELECTRIC STRIKE CONNECTION CURRENT TRANSFORMER SHORTING TERMINAL BLOCK. BUZZER STB GC STs TIMER SWITCH GROUNDING CONDUCTOR(S) ROUTED IN CODE SIZED CONDUIT, UON. 0 TERMINAL FOR FIELD CONNECT, SIZE&TYPE SUITABLE FOR CHIME ML MAGNETIC LOCK CONNECTION LOW VOLTAGE MOMENTARY CONTACT SWITCH, UPPER CASE LETTER CONDUCTOR INSTALLED. ® GROUND GRID BOND POINT $5A SUPERSCRIPT INDICATES CONNECTION TO LOW VOLTAGE RELAY C © SYSTEM CLOCK-WALL , CEILING CONTROLLING SIMILARLY MARKED LUMINAIRES. LED INDICATOR LIGHT, PUSH TO TEST, R=RED, G=GREEN, B= BLUE, 'Y=YELLOW, W=WHITE GROUND GRID BOND POINT-MECHANICAL CONNECTION ® REQUEST TO EXIT(WIRING TO ELECTRIFIED PANIC HARDWARE) ( O INTERCOM STATION-WALL, DESK SwP WEATHERPROOF SWITCH M E E= IBC 1007.8 COMPLIANT 2-WAY COMMUNICATIONS CALL STATION • GROUND GRID BOND POINT-EXOTHERMIC WELD CONNECTION L DELTA CONNECTION M=MASTER STATION TIGARD TUALATIN SCHOOL DISTRICT LINE VOLTAGE, VARIABLE SPEED FAN CONTROL SWITCH. LOCATE V=VIDEO INTERCOM SYSTEM REQUEST TO EXIT(WALL MOUNTED IR DETECTOR ABOVE DOOR) SV GROUNDED WYE CONNECTION GROUND BAR, SEE PLANS AND SPECIFICATIONS FOR DIMENSIONS AN[ TIGARD HIGH ADJACENT TO ADJACENT TO LIGHT SWITCHES. Sr CONNECTION TO GROUND M OM MICROPHONE JACK-WALL, FLOOR REQUIREMENTS MOTOR-RATED THERMAL OVERLOAD SWITCH - ER EMERGENCY DOOR RELEASE BUTTON GROUND ROD LOCATION PUSHBUTTON OR PUSHBUTTONS SCHOOL SORA LIGHTING CONTROL OVERIDE SWITCH. NUMBER=ZONE 100AT b\ ° ® GROUND ROD IN TEST WELL INTRUSION DETECTION KEYPAD-WALL MOUNTED CONTROLLED 225AF CIRCUIT BREAKER, WITH TRIP& FRAME AMPERE RATING AUDIOVISUAL WALL PLATE KP MODERNIZATIONi LIGHTNING PROTECTION PARAPET MOUNTED AIR TERMINAL �D DOOR POSITION MONITOR SWITCH PC PHOTOCELL DOAS FUSED SWITCH, WITH FUSE AND SWITCH AMPERE RATING X FLUSH FLOOR DEVICE-DEVICE TYPE PER SYMBOLS ABOVE X INDICATES QUANTITY OF CABLE/JACKS O LIGHTNING PROTECTION MID ROOF MOUNTED AIR TERMINAL Gg GLASS BREAK SENSOR EQUIPMENT OPERATOR PUSH BUTTON STATION. PROVIDED WITH 4 EQUIPMENT, INSTALLED AND CONNECTED BY ELECRTICAL, LION. PEDESTAL FLOOR DEVICE- DEVICE TYPE PER SYMBOLS ABOVE O LIGHTNING PROTECTION AIR TERMINAL Q MOTION DETECTOR INDIVIDUALLY MOUNTED CIRCUIT BREAKER X X INDICATES QUANTITY OF CABLE/JACKS 4 9 MD. PUSHBUTTON OR PUSHBUTTONS. �� LIGHTNING PROTECTION CONDUCTOR ROUTED DOWN DS DURESS PUSHBUTTON STATION TIGARD, OR. 92 52 CIRCUIT BREAKER, MEDIUM VOLTAGE, DRAWOUT W WIRELESS ACCESS POINT LOCATION-CEILING MOUNTED TC TIME CLOCK DRAWOUT CIRCUIT BREAKER ® LIGHTNING PROTECTION BOND PLATE L::11FIXED CAMERA-WALL,CEILING JOB NO: 16992.00 OS OCCUPANCY SENSOR-WALL MOUNTED B LIGHTNING PROTECTION BIMETAL CONNECTION q®< ®1 INDOOR DOME CAMERA-WALL/CEILING ISSUE DATE: 04/18/2018 GF GROUND FAULT TRIP UNIT OS 360 DEGREE OCCUPANCY SENSOR-CEILING MTD. Jurisdiction tamp Area EXPIRES: 12/31/19 OS 180 DEGREE OCCUPANCY SENSOR-CEILING MTD. gq BELL ALARM TRIP MODULE CONTACTS rO� PRO FF SHUNT TRIP UNIT 120VACORVOLTAGEASNOTED ELECTRICAL EQUIPMENT NAMING CONVENTION LEGEND �S��NGINEfj0�' OS CORRIDOR/AISLE OCCUPANCY SENSOR-CEILING MOUNTED ST 757 7PE 9 COMBINATION OCCUPANCY SENSOR&SWITCH GANGED UNDER A AM INTEGRAL AMMETER DISPLAY EXAMPLEWLEGEND EQUIPMENT TYPE POWER SYSTEMS VOLTAGE FLOOR ADDITIONAL DESIGNATION ` /-� COMMON COVER PLATE. OCCUPANY SENSOR TO CONTROL ALL OREGON Sa OS b LUMINAIRES IN ROOM WITH 1/2 LIGHT REDUCTION CONTROLLED BY - K - KEY INTERLOCK MCC- H M 1 A SUB-UNIT SUBSTATION BLANK-NORMAL LOADS H 480/277 VOLT 0-LOWER LEVEL (1st character) 4 SWBD-SWITCHBOARD M-MAIN UTILITY SERVICE L-208/120 VOLT 1 -MAIN LEVEL BLANK-PANEL �'P_�`�e� �2•�� SWITCH. CAPACITOR, POWER FACTOR CORRECTION, SIZE IN KVAR DP- U L D 1 A SWGR-SWITCHGEAR E-EMERGENCY POWER(Life Safety) MV-MEDIUM VOLTAGE 2-UPPER LEVEL D- DISTRIBUTION PNL FN T. BkOP' DP-DISTRIBUTION PANEL S-STANDBY POWER R- ROOF S-SWITCHBOARD T O THERMOSTAT-WALL, CEILING 10 XFR- H L 1 A PNL-BRANCH PANEL U-UNINTERRUPTIBLE POWER(UPS) M-MCC ATS-AUTOMATIC TRANSFER SWITCH C-CRITICAL POWER(Hospital) GENERATOR SWBD- M H SN 1 A BIATS-BYPASS ISOLATION ATS Q-EQUIPMENT POWER(Hospital) (2nd character) ELECTRICAL SEPO EPO HEAD PUSHBUTTON WITH GUARD.EMERGENCY POWER OFF, HEAVY.DUTY, OIL-TIGHT RED MUSHROOM- - MTS-MANUAL TRANSFER SWITCH S-LIFE SAFETY POWER(Hospital) BLANK-NOT USED U' LEGEND A N D �- FUSE, HOLDER& PULLER PNL- E H K 2 B I I XFR-TRANSFORMER N-NORTH WING Q LIGHTING CONTROL PANEL AND ASSOCIATED COMPONENTS. C CONNECTION TO CHILLER POWER ADDN L SEQ. UTX- UTILITY MAIN TRANSFORMER S-SOUTH WING PROVIDE CONTROL POWER AS REQUIRED OR AS INDICATED. SYSTEM DESIG. LETTERS MCC-MOTOR CONTROL CENTER E-EAST WING ABBREVIATIONS EQUIP. DESIG.SYSTEM FLOOR CB-ENCLOSED CIRCUIT BREAKER W-WEST WING a-�-o SOLENOID TYPE VOLTAGE FSW-FUSED DISCONNECT SWITCH K-KITCHEN DSW-NON-FUSED DISCONNECT SW. P-PROCESS EQUIP. w E0 . 00 X ISSUED AS PART OF THE DRAWING PACKAGE o o X ISSUED AS PART OF THE DRAWING PACKA E 0 0 • ISSUED FOR REFERENCE ONLY c c _ • ISSUED FOR REFERENCE ONLY c c Mcc E E 0 ' E 0 C a ass SHEET E E SHEET E o o P16c t aQ a s a a NUMBER SHEET NAME aNUMBER SHEET NAME a a LEGENDS, TABLES AND NOTES DIAGRAMS AND SCHEDULES E0.00 ELECTRICAL LEGEND AND ABBREVIATIONS X X X E5.01 ELECTRICAL SINGLE LINE DIAGRAM • 721 NW 9TH Ave, Suite 350 E0.01 ELECTRICAL DRAWING LIST X X X X X E5.02 PANELBOARD SCHEDULES Portland, Oregon 97209 E0.02 BASIS OF DESIGN AND NOTES X X • E5.03 PANELBOARD SCHEDULES T (206) 340 9500 F (206) 340 9519 E0.03 REFERENCE TABLES • X E5.04 PANELBOARD SCHEDULES E0.04 VOLTAGE DROP CALCULATIONS E5.05 PANELBOARD SCHEDULES E0.05 MECHANCIAL&PLUMBING EQUIPMENT CONNECTION SCHEDULE E5.11 SIGNAL RISER DIAGRAMS CIVIL ENGINEER & LANDSCAPE Cardno ELECTRICAL DEMO PLANS ENLARGED PLANS 6720 SW Macadam Ave Suite 200, ED1.12 DEMO PLAN-ELECTRICAL MAIN LEVEL X X • • E6.01 ENLARGED PLANS Portland, OR 97219 E6.02 ENLARGED PLANS T(503)-419-2500 ELECTRICAL SITE PLAN E6.03 ENLARGED PLANS STRUCTURAL ENGINEER E1.00 ELECTRICAL SITE PLAN • E6.04 ENLARGED PLANS-UNDERGROUND X X Catena Engineers E6.05 ENLARGED PLANS-UNDERGROUND X X 1500 NE Irving St., Suite 412 COMPOSITE PLANS Portland, OR 97232 E6.07 ENLARGED PLANS T(503)-467-4980 E1.10 POWER AND SIGNAL UNDERGROUND COMPOSITE X X E6.11 ENLARGED PLANS- MDF/IDF ROOMS E1.11 POWER AND SIGNAL LOWER LEVEL FLOOR PLAN COMPOSITE E6.12 ENLARGED PLANS-MDF/IDF ROOMS MECHANICAL ELECTRICAL & E1.12 POWER AND SIGNAL MAIN LEVEL FLOOR PLAN COMPOSITE PLUMBING ENGINEER E1.13 POWER AND SIGNAL UPPER LEVEL FLOOR PLAN SOUTH DETAILS Glumac COMPOSITE E9.03 ELECTRICAL DETAILS 900 SW Fifth Ave., Suite 1600 E1.14 POWER AND SIGNAL UPPER LEVEL FLOOR PLAN NORTHPortland, OR 97204 COMPOSITE E9.04 ELECTRICAL DETAILS X T(503)-227-5280 E1.15 POWER AND SIGNAL ROOF FLOOR PLAN COMPOSITE E9.05 ELECTRICAL DETAILS X X E9.06 ELECTRICAL DETAILS X FOOD SERVICE CONSULTANT SOUTH SECTOR PLANS E9.07 ELECTRICAL DETAILS X X Webb Foodservice Design E911 LOW-VOLTAGE DETAILS 3700 SE Lafayette Ct. . E2.11 POWER AND SIGNAL UNDERGROUND-AREA N1 X Portland, OR 97202 E2.12 POWER AND SIGNAL UNDERGROUND-AREA N2 X T(503)-236-8566MDF LEGENDS,TABLES AND NOTES E2.23 POWER AND SIGNAL LOWER LEVEL-AREA S1 MDF.E01 BASIS OF DESIGN AND NOTES X ACOUSTIC &AV CONSULTANT E2.24 POWER AND SIGNAL LOWER LEVEL-AREA S2 MDF.E03 MECH&PLUMB EQUIP CONN&LUMINAIRE SCHEDULES X The Greenbusch Group E2.25 POWER AND SIGNAL MAIN LEVEL AREA S1 + UPPPER LEVEL AREA 1900 W. Nickerson St., Suite 201 S1 E2.26 POWER AND SIGNAL UPPER LEVEL-AREA S2 MDF DEMO PLANS Seattle,WA 98119 MDF.E11 ELECTRICAL PLANS-DEMOLITION X T 206-378-0569 E2.27 POWER AND SIGNAL ROOF-AREA S1 E2.28 POWER AND SIGNAL ROOF FLOOR-S2 COST CONSULTANT MDF PLANS Construction Focus NORTH SECTOR PLANS MDF.E20 ELECTRICAL PLANS-LOWER LEVEL X 740 Almaden St. MDF.E21 ELECTRICAL PLANS-MAIN LEVEL X Eugene, OR 97402 E2.13 POWER AND SIGNAL MAIN LEVEL-AREA N1 MDRE22 ELECTRICAL PLANS-UPPER LEVEL/ROOF X T 541-686-2031 E2.14 POWER AND SIGNAL MAIN LEVEL- AREA N2 E2.15 POWER AND SIGNAL UPPER LEVEL-AREA N1 MDF DIAGRAMS AND SCHEDULES E2.16 POWER AND SIGNAL UPPER LEVEL-AREA N2 MDF.E51 SINGLE-LINE DIAGRAM AND PANEL SCHEDULES X E2.17 POWER AND SIGNAL ROOF PLAN-AREA N1 E2.18 POWER AND SIGNAL ROOF PLAN-AREA N2 MDF.T1 TECHNOLOGY-MDF PLANS X E2.21 POWER AND SIGNAL UNDERGROUND-AREA S1 X E2.22 POWER AND SIGNAL UNDERGROUND-AREA S2 X EAST SECTOR PLANS E2.32 POWER AND SIGNAL MAIN LEVEL-AREA E1 E2.33 POWER AND SIGNAL ROOF-AREA E1 DATE TIGARD TUALATIN SCHOOL DISTRICT TIGARD HIGH SCHOOL MODERNIZATION: 9000 SW DURHAM RD. TIGARD, OR. 97224 JOB NO: 16992.00 ISSUE DATE: 04/18/2018 Jurisdiction Stamp Area EXPIRES: 12/31/19 iD PROFFsf� 757 7PE a�OREGON FN T BL\PCO ELECTRICAL '-'- DRAWING LIST 0 75 W E0 . 01 BASIS OF DESIGN ELECTRICAL NOTES POWER NOTES LOW-VOLTAGE NOTES DEMOLITION NOTES 1. PURPOSE: 10. PROVIDE EACH CTE SPACE WITH: 1. THE CIRCUITING SHOWN IS DIAGRAMMATIC. THE DRAFTING METHOD 1. WHERE POSSIBLE, BOXES SHALL BE IN SEPARATE STUD SPACES FROM A WHERE POSSIBLE, BOXES FOR COMMUNICATIONS OUTLETS SHALL BE IN 1. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR REVIEWING bassetti WHICH MOST SIMPLY CONVEYS THE CIRCUITING INTENT AT A GIVEN BOXES SERVING OTHER ROOMS TO MINIMIZE SOUND TRANSFER. SEPARATE STUD SPACES FROM BOXES SERVING OTHER ROOMS TO ARCHITECTURAL DEMOLITION PLANS. FOR WALLS, SOFFITS, CASEWORK, a/'C17&CtS A. THIS BASIS OF DESIGN NARRATIVE IS INTENDED TO BE USED TO SET a. TWO CEILING MOUNTED DUPLEX RECEPTACLES FOR LOCATION IS EMPLOYED. MINIMIZE SOUND TRANSFER. ISLANDS, CEILINGS, ETC. SHOWN TO BE DEMOLISHED, REMOVE THE THE BASIS OF UNDERSTANDING OF THE PROJECT SCOPE BETWEEN PROJECTORS 2. COORDINATE EXACT MECHANICAL EQUIPMENT LOCATIONS AND FOLLOWING: THE OWNER AND THE ASSOCIATED DESIGN PROFESSIONALS,AND TO b. TEN CEILING MOUNTED DUPLEX RECEPTACLES FOR DROP 2. REFER TO ONE LINE DIAGRAM FOR ADDITIONAL INFORMATION ON NAMED REQUIREMENTS WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN. B REFER TO ARCHITECTURAL FLOOR PLANS, INTERIOR ELEVATIONS AND COMMUNICATE TO THE CONTRACTORS THAT SCOPE OF WORK. IT CORD REELS ELECTRICAL EQUIPMENT SHOWN. COORDINATE CONDUIT REQUIREMENTS FOR ALL HVAC EQUIPMENT WITH DETAIL DRAWINGS PRIOR TO ROUGH-IN FOR EXACT LOCATION OF A. TELECOM OUTLET BOXES AND RACEWAYS, COORDINATE CABLE 721 NW 9TH Ave, Suite 350 SHALL ALSO BE CONSIDERED BINDING IN THE SAME MANNER AS THE c. FOUR WALL MOUNTED 6-30R RECEPTACLES FOR YET TO BE CONTROLS CONTRACTOR. RECEPTACLES, FLOOR BOXES,AND OUTLETS. INFORM ENGINEER OF REMOVAL WITH GENERAL CONTRACTOR AND OWNER. Portland, Oregon 97209 DRAWINGS AND SPECFICATIONS ARE. SPECIFIED EQUIPMENT 3. REFER TO DETAIL DRAWINGS FOR ADDITIONAL INFORMATION.ALL CONFLICTS VIA REQUEST-FOR-INFORMATION (RFI). d. FOUR WALL MOUNTED CONVENIENCE DUPLEX RECEPTACLES DETAILS APPLY FOR ALL APPLICABLE SITUATIONS WHETHER REFERENCED 3. FOR ELECTRICAL CONNECTIONS AND CIRCUITING TO MECHANICAL B. POWER OUTLETS,WIREMOLD, RECEPTACLES AND ALL OTHER T (206) 340 9500 F (206) 340 9519 2. PROJECT DESCRIPTION: ON EACH WALL OR NOT, UON. EQUIPMENT SHOWN ON PLANS, REFER TO MECHANICAL AND PLUMBING C COORDINATE LOCATIONS OF WALL-MOUNTED DEVICES WITH ELECTRICAL DEVICES INCLUDING THEIR J-BOXES,CONDUIT AND WIRE. EQUIPMENT CONNECTION SCHEDULE. ARCHITECTURAL INTERIOR ELEVATIONS.WHERE DEVICES ARE LOCATED A. TIGARD HIGH SCHOOL LOCATED AT 900 SW DURHAM RD. TIGARD, OR 11. PROVIDE EACH COMPUTER LAB WITH: 4. CONTRACTOR IS RESPONSIBLE TO REVIEW ARCHITECTURAL DRAWINGS ADJACENT TO ELECTRICAL DEVICES, LOCATE BOTH DEVICES WITHIN 6- C. LIGHT SWITCHES INCLUDING THEIR J-BOXES, CONDUIT AND WIRE. CIVIL ENGINEER & LANDSCAPE 97224 WILL UNDERGO A PARTIAL DEMOLITION AND EXPANSION OF THE TO CONFIRM CEILING TYPES IN ALL ROOMS(ACCESSIBLE, EXPOSED, OR 4. PROVIDE 4" HOUSEKEEPING PAD FOR ALL FLOOR MOUNTED ELECTRICAL INCHES OF ONE ANOTHER.ALIGN DEVICES VERTICALLY. WEST SIDE OF THE CURRENT HIGH SCHOOL. THE RENOVATED SPACE a. ONE QUADPLEX RECEPTACLE FOR EACH COMPUTER WORK "HARD")AND TO USE THE APPROPRIATE WIRING METHOD FOR EACH TYPE. EQUIPMENT. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION. D. FIRE ALARM AND OTHER LOW-VOLTAGE DEVICES INCLUDING THEIR J- Cardno WILL INCLUDE A MIX OF ADMINISTRATIVE OFFICES, CLASSROOMS, STATION INSURE ALL J-BOXES ARE ACCESSIBLE AFTER ALL OTHER TRADE'S WORK D CONTRACTOR IS RESPONSIBLE TO REVIEW ARCHITECTURAL DRAWINGS TO BOXES, CONDUIT AND WIRE. 6720 SW Macadam Ave Suite 200, INDOOR ATHLETIC FACILITIES,AS WELL AS A NEW KITCHEN AND b. ONE FLOORBOX/POKE THRU PER TWO COMPUTER WORK IS COMPLETED. DO NOT LOCATE ANY J-BOXES ON "HARD"CEILINGS;ALL 5. REFER TO ONE-LINE DIAGRAM FOR ADDITIONAL INFORMATION ON NAMED CONFIRM CEILING TYPES IN ALL ROOMS ACCESSIBLE, EXPOSED, OR"HARD" Portland, 97219 ( ) T(503)-4199--2500 OTHER SPECIALTY SPACES SUCH AS AN AUTOMOTIVE LAB, MAKER STATIONS LOCATED AWAY FROM WALLS. WIRING MUST BE ACCESSIBLE THROUGH DEVICE ONLY IN "DAISEY-CHAIN" ELECTRICAL EQUIPMENT SHOWN. AND TO USE APPROPRIATE ROUTING METHOD FOR EACH DEVICE PER DIV 27 E. FOR ALL J-BOXES ON EXPOSED CEILINGS AND WALLS, REWORK SPACE,CERAMICS, GRAPHIC DESIGN LAB, ETC. c. ONE CEILING MOUNTED DUPLEX RECEPTACLE FOR METHOD OR WITH DEDICATED HOMERUNS TO EACH DEVICE. J-BOXES MAY SPECIFICATIONS. CONDUIT AND WIRING IF CIRCUIT CONTAINED OR USED IN J-BOX STRUCTURAL ENGINEER PROJECTOR BE LOCATED ABOVE OTHER TRADE'S ACCESS DOORS IF FEASIBLE AND 6. PROVIDE SPECIAL RECEPTACLES THAT MATCH CORD AND CAP PROVIDED SERVES EXISTING TO REMAIN LIGHTING OR DEVICES, RELOCATE J-BOX Catena Engineers B. AN EXISTING AUXILIARY GYM BUILDING TO THE WEST OF THE MAIN d. ONE WALL MOUNTED DUPLEX RECEPTACLE FOR WALL DOES NOT INTERFERE WITH ACCESS. WITH EQUIPMENT UNLESS NOTED OTHERWISE. USE ADJACENT NEMA E COMMUNICATION OUTLETS HEIGHTS SHOWN ARE MEASURED FROM THE AS REQUIRED TO ABOVE ACCESSIBLE CEILING. INTENT IS TO HAVE NO 1500 NE Irving St., Suite 412 BUILDING WILL BE DEMOLISHED.ANY ITEMS THAT REQUIRE POWER MOUNTED PROJECTOR DISPLAY CONFIGURATION NUMBER IF ONE IS SHOWN. FINISH FLOOR TO THE CENTERLINE OF THE OUTLET UNLESS OTHERWISE BLANK COVERPLATES ON FINISHED SURFACES AT COMPLETION OF Portland, OR 97232 AND/OR DATA THAT ARE SERVED BY THAT BUILDING AND ARE TO e. TWO WALL MOUNTED CONVENIENCE DUPLEX RECEPTACLES 5. REFER TO ONE-LINE DIAGRAM FOR ADDITIONAL INFORMATION ON NAMED NOTED. PROJECT. T(503)-467-4980 REMAIN SHALL BE RE-SERVED BY THE MAIN BUILDING. ON EACH WALL ELECTRICAL EQUIPMENT SHOWN. 7. PROVIDE ALL RECEPTACLES WITHIN 6'OF A SINK,AND WITHIN THE SAME SPACE,WITH GFCI PROTECTION. F EACH ELEVATOR SHALL HAVE AN INDEPENDENT DEDICATED TELEPHONE F. EXISTING LUMINAIRES,ASSOCIATED CONDUIT AND CONDUCTORS. MECHANICAL ELECTRICAL & 3. LIGHTING: 12. PROVIDE EACH ART ROOM WITH: 6. INSTALL ALL EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS AND LINE NOT SHARED WITH OTHER ELEVATOR PHONES. ELEVATOR PHONE PLUMBING ENGINEER INSTRUCTIONS. THESE DRAWINGS ARE DIAGRAMMATIC. 8. REFER TO ARCHITECTURAL FLOOR PLANS, INTERIOR ELEVATIONS AND SHALL BE ADA COMPLIANT(PUSH BUTTON). G. ALL EXIT SIGNS. Glumac A. REFER TO LIGHTING NOTES FOR INFORMATION REGARDING GENERAL a. ONE CEILING MOUNTED DUPLEX RECEPTACLE FOR DETAIL DRAWINGS PRIOR TO ROUGH-IN FOR EXACT LOCATION OF 900 SW Fifth Ave., Suite 1600 LIGHTING INTENT AND FIXTURE SELECTION, REFER TO LIGHTING PROJECTOR 7. WHERE NOTED AS OWNER-SUPPLIED ON DRAWINGS, CONTRACTOR SHALL RECEPTACLES, FLOOR BOXES AND OUTLETS. INFORM ENGINEER OF G NO CONDUIT RUN TO EXCEED 100'WITHOUT THE INSTALLATION OF A PULL 2. WHERE REMODELING INTERFERES WITH EXISTING CIRCUITS AND Portland, OR 97204 CONTROLS BASIS OF DESIGN FOR LIGHTING CONTROL INTENT. b. ONE WALL MOUNTED RECEPTACLE FOR PROJECTOR DISPLAY RECEIVE, INSTALL,AND CONNECT EQUIPMENT PER MANUFACTURER'S CONFLICTS. BOX. EQUIPMENT WHICH IS NOT TO BE REMOVED, SUCH CIRCUITS AND T(503)-227-5280 c. TWO WALL MOUNTED CONVENIENCE DUPLEX RECEPTACLES REQUIREMENTS. PRIOR TO INSTALLATION OF OWNER-SUPPLIED EQUIPMENT SHALL BE REWORKED AND RELOCATED AS REQUIRED TO FOOD SERVICE CONSULTANT 4. FIRE ALARM: ON EACH WALL EQUIPMENT, CONTRACTOR SHALL INSPECT/TEST EQUIPMENT AND INFORM 9. COORDINATE EXACT LOCATIONS OF POWERED EQUIPMENT/DEVICES(PLAN H CONDUIT BENDS SHALL NOT EXCEED(2)90 DEGREE BENDS OR 180 DEGREES MAINTAIN SERVICE TO ITEM. REFER ALL QUESTIONABLE SITUATIONS TO PROJECT MANAGER OF ANY DEFECTS. FAILURE TO DO SO SHALL MEAN AND ELEVATION LOCATIONS)AND REQUIREMENTS WITH OWNER AND WITHOUT THE INSTALLATION OF A PULL BOX. THE ENGINEER. IF AND WHEN REWORKING CIRCUITRY, DO NOT LOCATE J- Webb Foodservice Design A. FIRE ALARM SHALL BE DESIGN-BUILD BASED ON PERFORMANCE 13. PROVIDE EACH MAKER SPACE WITH: THAT THE EQUIPMENT IS IN GOOD WORKING CONDITION. CONTRACTOR ARCHITECT PRIOR TO ROUGH-IN. EXAMPLES INCLUDE: BOXES ON WALLS, EXCEPT ONES REQUIRED TO MOUNT THE ITEM. I.E.AT 3700 SE Lafayette Ct. SPECIFICATIONS. COMPLETE FIRE ALARM PLANS, DIAGRAMS,AND SHALL BE RESPONSIBLE FOR INSTALLATION AND TESTING OF SUCH I COORDINATE REQUIREMENTS FOR ACCESS CONTROL DOORS WITH DIVISION THE COMPLETION OF THE PROJECT THERE SHALL BE NO J-BOXES WITH Portland, OR 97202 CALCULATIONS SHALL BE PROVIDED BY THE FIRE ALARM a. ONE CEILING MOUNTED DUPLEX RECEPTACLE FOR EQUIPMENT. A. TV/DISPLAY LOCATIONS 08 SPECIFICATIONS FOR DOOR HARDWARE. BLANK COVERPLATES ON WALLS OR CEILINGS,THE PROJECT SHALL T(503)-236-8566 CONTRACTOR AS PART OF A DEFERRED SUBMITTAL. PROJECTOR B. COPY MACHINE LOCATIONS APPEAR AS NEW CONSTRUCTION. ACOUSTIC &AV CONSULTANT b. EIGHT CEILING MOUNTED DUPLEX RECEPTACLES FOR DROP 8. PLANS INDICATE THE APPROXIMATE LOCATIONS(PLUS/MINUS A FEW FEET) C. KITCHEN/KITCHENETTE EQUIPMENT LOCATIONS, E.G. J PERFORM ALL WORK IN ACCORDANCE WITH APPLICABLE LOCAL, STATE,AND 5. ELECTRICAL DESIGN CORD REELS OF ITEMS SHOWN UNLESS DIMENSIONS ARE CALLED OUT. a. DISHWASHERS FEDERAL CODES, LAWS,AND REGULATIONS. 3. REMOVE ALL EXISTING BRANCH CIRCUIT CONDUCTORS AND CONDUITS The Greenbusch Group c. TWO WALL MOUNTED 6-30R RECEPTACLES FOR YET TO BE b. ICE MACHINES ASSOCIATED WITH REMOVED ELECTRICAL EQUIPMENT AND DEVICES BACK 1900 W. Nickerson St., Suite 201 A. NORMAL POWER: SPECIFIED EQUIPMENT-3D PRINTER 9. ALL NEW RACEWAYS AND CONDUCTORS SHALL BE INSTALLED c. MICROWAVES K ALL MATERIALS AND EQUIPMENT SHALL BE LISTED BY THE UNDERWRITER'S TO THE EXISTING HOMERUN FROM WHICH THEY ARE FED OR THE NEAREST Seattle,WA 98119 d. FOUR WALL MOUNTED CONVENIENCE DUPLEX RECEPTACLES CONCEALED; CUT AND PATCH EXISTING WALLS TO ACCOMODATE NEW LABORATORIES(UL). ACTIVE DEVICE THAT IS TO REMAIN. REMOVE ALL OLD TYPE WIRING IF IT IS T 206-378-0569 1. ALL EXISTING ELECTRICAL DISTRIBUTION EQUIPMENT LOCATED IN ON EACH WALL RACEWAY INSTALLATION.ALL CONDUITS TO BE INSTALLED 90 DEGREES 10. FLOOR BOXES NOT RATED FOR 90°C. COST CONSULTANT THE PORTION OF THE BUILDING BEING RENOVATED WILL BE TO BUIDLING LINES. L ALL EXTERIOR DEVICES ARE REQUIRED TO BE PAINTABLE TO MATCH DEMOLISHED, UNLESS OTHERWISE NOTED.THIS INCLUDES 14. PROVIDE EACH CERAMICS SPACE WITH: A. FLOOR BOXES SHALL BE TYPE EFB6S BY LEGRAND UNLESS NOTED BUILDING FINISHES. COORDINATE FINISH COLORS WITH ARCHITECT PRIOR 4. IF REASONABLE, EXISTING BRANCH CIRCUIT HOMERUN CONDUITS AND Construction Focus PANELBOARDS, CONDUIT, CONDUCTORS AND DEVICES. EXISTING 10. CIRCUIT SIZES ARE NOT SHOWN ON THE PLANS. CONTRACTOR SHALL USE OTHERWISE. PROVIDE(4)5-20 RECEPTACLES FOR POWER. REFER TO TO INSTALLATION. WIRES MAY REMAIN AND BE REUSED IN THE NEW CONSTRUCTION PHASE 740 Almaden 7 402 FEEDERS SERVING DISTRIBUTION EQUIPMENT BEING DEMOLISHED a. ONE CEILING MOUNTED DUPLEX RECEPTACLE FOR CIRCUITS SIZES INDICATED IN NOTES OR RESPECTIVE SCHEDULES(PNL, AV-SERIES OF DRAWINGS FOR AV SCOPE OF WORK. OF WORK. THE INTENT IS TO REUSE THE MAIN INFRASTRUCTURE AND Eugene, OR 9 WILL BE DEMO'D BACK TO THE PORTION OF THE BUILDING PROJECTOR MCC, ETC.)AND INFORMATION IN THE FEEDER AND BRANCH CIRCUIT M PROVIDE PULL STRING IN ALL CONDUITS AT TIME OF CONDUIT INSTALLATION REMOVE ALL THE BRANCH CIRCUITING THAT WILL NO LONGER BE USED. T 541-686-20311 EXISTING TO REMAIN,WHERE THE EXISTING CONDUCTORS WILL b. FOUR WALL MOUNTED CONVENIENCE DUPLEX RECEPTACLES SCHEDULES. B. PROVIDE INTERNAL BLANK BRACKETS FOR ALL UNUSED FLOOR BOX AND AGAIN AT TIME OF CABLE INSTALLATION. REMOVE EXISTING HOMERUNS BACK TO NEAREST USABLE EXISTING BE SAFED-OFF AND THE EXISTING CONDUIT WILL BE CAPPED. ON EACH WALL COMPARTMENTS. JUNCTION BOX IF THEY WILL NOT BE USED AT THE COMPLETION OF THE 11. BRANCH CIRCUIT WIRE SIZES N FOR CABLE INSTALLED IN OUTDOOR ENVIRONMENTS, OR INSTALLED BELOW PROJECT. 2. THE RENOVATED PORTION OF TIGARD HIGH SCHOOL WILL BE 15, PROVIDE EACH FITNESS ROOM WITH: C. COORDINATE WITH ARCHITECT TO DETERMINE COVERPLATE STYLE SLAB ON GRADE, PROVIDE CABLE RATED FOR INDOOR/OUTDOOR USE. SERVED FROM(1) NEW 480V, 3PHASE, 3000A MAIN SWITCHBOARD A. WHERE BRANCH CIRCUIT WIRE SIZES ARE NOT EXPLICITLY CALLED AND COLOR. 5. CONTRACTOR SHALL VERIFY CIRCUITS WITH TRACING DEVICE AND LABEL LOCATED IN A NEW MAIN ELECTRICAL ROOM AND FED FROM A a. WALL MOUNTED CONVENIENCE DUPLEX RECEPTACLES OUT. BRANCH CIRCUIT WIRE SIZES FOR EACH NEW OR MODIFIED 0 PROVIDE 24-STRAND OS1 SINGLEMODE FIBER OPTIC CABLING FROM MDF TO CIRCUITS AVAILABLE AT EACH J-BOX, MODIFY DRAWINGS AS REQUIRED TO NEW PAD MOUNTED UTILITY TRANSFORMER. SPACED 20'ON CENTER THROUGHOUT THE SPACE. CIRCUIT SHALL BE BASED ON THE CIRCUIT BREAKER INDICATED ON D. VERIFY FINAL AND EXACT LOCATIONS WITH ARCHITECT AND OWNER. EACH IDF ROOM,AND DEMARC ROOM. TERMINATE ON LC-ADAPTER PANELS DOCUMENT ACTUAL CIRCUITING. THE ELECTRICAL PANEL SCHEDULES. PROVIDE THE FOLLOWING: WITHIN RACK-MOUNTED FIBER DISTRIBUTION UNIT. B. EMERGENCY/STANDBY POWER: 16. PROVIDE AUTOSHOP WITH: 11. POKE-THRU DEVICES 6. DO NOT REMOVE ANY CONDUITS SERVING EXISTING TO REMAIN ITEMS, a. 20A-1 P C.B. 20.1 BRANCH CIRCUIT P FOR WIRELESS ACCESS POINT LOCATIONS, PROVIDE(2) CAT6A CABLES WITH ESPECIALLY TO: 1. A NEW 150KW GENERATOR WITH AN OUTDOOR ENCLOSURE AND a. ONE WALL MOUNTED RECEPTACLE FOR PROJECTOR DISPLAY b. 20A-2P C.B. 20.2 BRANCH CIRCUIT A. POKE-THRU DEVICES FOR CONFERENCE AND MEETING ROOMS SHALL A 20'LOOP(BLUE CABLE YELLOW JACKS GREY FACEPLATE). LOCATIONS 12HR BELLY TANK WILL BE PROVIDED. b. TWO WALL MOUNTED CONVENIENCE DUPLEX RECEPTACLES c. 20A-3P C.B. 20.3 COPPER FEEDER BE LEGRAND TYPE 6AT FLUSH STYLE DEVICES UNLESS NOTEDA. FAN POWERED BOXES AND OTHER MECHANICAL EQUIPMENT TO ON EACH WALL d. 30A-1P C.B. 30.1 BRANCH CIRCUIT OTHERWISE. PROVIDE(4)5-20 RECEPTACLES FOR POWER. REFER TO ARE NOT YET SHOWN ON THE FLOOR PLANS, BUT SHOULD BE ASSUMED TO BE AS FOLLOWS: REMAIN. REFER TO MECHANICAL DRAWINGS FOR SCOPE OF WORK. 2. A DEDICATED AUTOMATIC TRANSFER SWITCH WILL BE PROVIDED e. 30A-2P C.B. 30.2 BRANCH CIRCUIT T-SERIES OF DRAWINGS FOR RELATED TELECOM AND AV SCOPE OF TO SERVE THE FOLLOWING EMERGENCY LOADS: 6. MECHANICAL PLUMBING EQUIPMENT POWER CONNECTIONS f. 30A-3P C.B. 30.3 COPPER FEEDER WORK. (1)WIRELESS ACCESS POINT LOCATION PER EVERY 50 FEET OF B. PANELS, DISTRIBUTION PANELS,TRANSFORMERS, ETC., UON. a. EGRESS LIGHTING A. PROVIDE POWER TO NEW MECHANICAL AND PLUMBING EQUIPMENT/ 12. VOLTAGE DROP B. PROVIDE BLANK COVERS FOR ALL UNUSED POKE-THRU DEVICE CORRIDOR. C. HVAC CONTROLS AND CONTROL PANELS, UNLESS THE PIECE OF HVAC b. FIRE ALARM SYSTEM DEVICES. OPENINGS. (1)WIRELESS ACCESS POINT LOCATION PER CLASSROOM EQUIPMENT IS TO BE REMOVED. REFER TO MECHANICAL DRAWINGS A. BRANCH CIRCUIT WIRE SIZES CORRESPOND TO TYPICAL SCENARIOS AND SPECS. FOR SCOPE OF WORK. 3. A SECONDARY AUTOMATIC TRANSFER SWITCH WILL BE PROVIDED B. CIRCUIT AND POWER WIRING BY DIVISION 26 WHERE VOLTAGE DROP IS LESS THAN 3%FROM THE UPSTREAM C. COORDINATE WITH ARCHITECT TO DETERMINE COVERPLATE STYLE (2)WIRELESS ACCESS POINT LOCATIONS PER CLASSROOM LAB TO SERVE THE FOLLOWING STANDBY LOADS: BRANCH PANEL. CONTRACTOR IS REQUIRED TO UPSIZE BRANCH AND COLOR. D. CONDUITS AND J-BOXES TO FIRE ALARM DEVICES ON EXISTING TO C. DISCONNECT SWITCHES ARE BY DIVSION 26 CIRCUITS AS REQUIRED TO KEEP THE VOLTAGE DROP FROM REMAIN WALLS. a. MDF SERVERS EXCEEDING 3%. D. VERIFY FINAL AND EXACT LOCATION WITH ARCHITECT AND OWNER. b. IDF RACKS D. VARIABLE FREQUENCY DRIVES(VFDS)AND STARTERS ARE BY E. BRANCH CIRCUIT WORK SERVING EXISTING LIGHTING TO REMAIN. c. MDF&IDF ROOM MECHANICAL COOLING DIVISION 23 B. VOLTAGE DROP TABLES HAVE BEEN PROVIDED ON SHEET E0.03 FOR E. PROVIDE POWER TO EACH NEW TRAP PRIMER FROM THE NEAREST d. SECURITY SYSTEM THE CONTRACTOR'S USE IN DETERMINING APPROPRIATE WIRE SIZES NEW RECEPTACLE CIRCUIT. F. DOOR HOLDERS, ROLL-DOWN FIRE DOORS, ROLL-UP DOORS AND e. KITCHEN WALK-IN FREEZER E. MECHANICAL CONTROLS ARE BY DIVISION 23 BASED ON TOTAL HOMERUN DISTANCE BETWEEN THE FEEDING THEIR ASSOCIATED POWER AND CONTROL WIRING, LION. f. KITCHEN WALK-IN COOLER BRANCH PANEL AND THE SERVED EQUIPMENT/DEVICE,AND THE g. KITCHEN HOOD EXHAUST F. EXAMPLES OF EQUIPMENT/DEVICES REQUIRING POWER ASSOCIATED ELECTRICAL LOAD. G. EXTERIOR LIGHTING AND ASSOCIATED LIGHTING CONTROL WIRING. CONNECTIONS INCLUDE: C. DISTRIBUTION C. PROVIDE J-BOX/WIREWAY SPLICES AS REQUIRE TO UPSIZE/DOWNSIZE H. CONTROL, POWER WIRING AND TELECOM WIRING ASSOCIATED WITH 1. POWER WILL TYPICALLY BE DISTRIBUTED THROUGHOUT THE 1. FAN COIL UNITS(FCU'S)-TYPICALLY 208V/1 PH/15A CONNECTIONS CONDUCTORS TO ENSURE WIRE/LUG COMPATIBILITY AT BRANCH ALL ELEVATORS. BUILDING AT 480/277V FOR MECHANICAL SYSTEMS, LIGHTING,AND PANELS AND SERVED EQUIPMENT/DEVICES. OTHER LARGE EQUIPMENT,AND AT 208/120V FOR CONVENIENCE 2. WATER HEATERS-TYPICALLY 480V/3PH CONNECTIONS I. SECURITY DEVICES, EQUIPMENT, CONDUIT AND WIRING, UNLESS POWER AND OTHER SMALL MEISCELLENOUS EQUIPMENT/DEVICES. 13. ALL EXPOSED CONDUIT LOCATED WITHIN THE OPEN TO STRUCTURE OTHERWISE NOTED. 3. HEAT TRACE ENVIRONMENT SHALL BE COORDINATED WITH THE DESIGN TEAM. RUNS 2. 480V/277V AND 208/120V BRANCH PANELS SHALL BE PROVIDED IN SHOULD BE ORGANIZED AND NEATLY ROUTED THROUGHOUT THE SPACE. 7. ALL REMOVED ELECTRICAL MATERIAL, INCLUDING WIRING, RACEWAYS, ELECTRICAL ROOMS/CLOSETS LOCATED THROUGHOUT THE 7. COMMUNICATIONS ELECTRICAL SUBCONTRACTOR TO PROVIDE PROPOSED ROUTINGS FOR OUTLETS, DEVICES,AND SUPPORTS SHALL BECOME THE PROPERTY OF FACILITY. STEP-DOWN TRANSFORMERS SHALL BE PROVIDED AS DESIGN TEAM APPROVAL PRIOR TO INSTALLATION. SURFACE MOUNTED THE CONTRACTOR AND SHALL BE REMOVED FROM THE JOB SITE. REQUIRED FOR 208/120V BRANCH PANELS. A. COMMUNICATIONS BACKBONE CABLING: MC CABLE IS NOT ALLOWED ON ANY OPEN TO STRUCTURE ENVIRONMENT. CONDUIT RUNS THAT NEED TO ROUTE AROUND EXISTING BEAMS TO BE 8. CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO SUBMISSION OF BID 3. EITHER A CONTACTOR PANEL AND/OR SHUNT-TRIP CIRCUIT 1. PROVIDE 24-STRAND OS1 SINGLEMODE FIBER TO COORDINATED WITH THE DESIGN TEAM PRIOR TO INSTALL. AND FIELD VERIFY ALL EXISTING CONDITIONS AND THE EXTENT OF THE BREAKERS SHALL BE PROVIDED FOR THE KITCHEN, TO PROVIDE DEMOLITION WORK,ALL ASSOCIATED DEMOLITION COSTS SHALL BE CODE-REQUIRED AUTOMATIC SHUT OFF OF KITCHEN EQUIPMENT 8. BID-ALTERNATE - PV SYSTEM INCLUDED IN THE BID PRICE. NO EXTRA PAYMENT WILL BE ALLOWED FOR _ BELOW HOODS. WORK REQUIRED BECAUSE OF DISCERNIBLE CONDITIONS,WHETHER OR A. AS A BID-ALTERNATE, PROVIDE PRICING THAT INCLUDES PROVIDING A NOT SPECIFICALLY SHOWN ON THESE DRAWINGS. D. RECEPTACLES: 230KW PV SYSTEM. 4� DATE 1. ALL RECEPTACLES SHALL COMPLY WITH NEMA, NFPA AND UL. B. PV SYSTEM SHALL BE DESIGN-BUILD. REVISIONS DUPLEX AND QUADPLEX RECEPTACLES SHALL BE SINGLE PHASE, 20 AMPS, 120 VOLT, NEMA 5-20R. C. THE PV ARRAY WOULD BE LOCATED ON THE ROOF OF THE NEW NORTH WING,AND WOULD TIE INTO THE NEW MAIN SWITCHBOARD IN 2. GROUND FAULT CIRCUIT INTERRUPTER(GFCI) DUPLEX THE NEW MAIN ELECTRICAL ROOM. RECEPTACLES SHALL BE PROVIDED AT LOCATIONS WITHIN SIX FEET OF A WATER SOURCE SUCH AS A SINK. GFCI RECEPTACLES D. BID-ALTERNATE PRICING SHALL INCLUDE ANY UP-SIZING AND/OR SHALL NOT SERVE OTHER RECEPTACLES FROM THEIR LOAD SIDE MODIFICATIONS TO THE MAIN SWITCHBOARD(IN COMPARISON TO THE TERMINALS. BASE BID) REQUIRED TO SUPPORT THE PV SYSTEM. 3. PROVIDE CONVENIENCE RECEPTACLES THROUGHOUT COMMON E. BID-ALTERNATE PRICING SHALL INCLUDE ANY MODIFICATIONS TO THE SPACES. MAIN ELECTRICAL ROOM AS REQUIRED, IN CONSIDERATION OF PV- RELATED EQUIPMENT AND ASSOCIATED SPACE REQUIREMENTS. 4. PROVIDE RECEPTACLES IN CORRIDORS FOR CLEANING MACHINES AT NO GREATER THAN 50' SPACING. THESE RECEPTACLES SHALL 9. CONSTRUCTION PHASING BE ON A DEDICATED CIRCUIT SERVING ONLY CORRIDOR RECEPTACLES. A. THE PROJECT PHASING AND ITS IMPACTS TO THE CONSTRUCTION OF TIGARD TUALATIN SCHOOL DISTRICT THE MECHANICAL, ELECTRICAL, PLUMBING, LIGHTING AND LOW 5. PROVIDE MDF ROOM WITH: VOLTAGE SYSTEMS SHALL BE WHOLLY OWNED BY THE CM/GC TIGARD H (CONSTRUCTION MANAGER/GENERAL CONTRACTOR)AND THEIR SUB- a. ONE L6-30R FED FROM A STANDBY PANEL MOUNTED TO THE CONTRACTORS. TEMPORARY FIRE,WATER, SANITARY, STORM, SCHOOL TOP OF EACH RACK[QTY. OF 6] POWER, LIGHTING AND CONDITIONING SHALL BE COORDINATED IN CONJUNCTION WITH FINAL DIRECTION FROM THE OWNER, BASED ON b. FOUR NORMALLY POWERED WALL MOUNTED QUADPLEX THE OWNER'S NEEDS(SAFETY, FUNCTIONALITY, ETC) DURING THE MODERNIZATION� RECEPTACLES ACTIVE CONSTRUCTION SCHEDULE. A SEPARATE"PHASING PLAN" SHALL BE CREATED BY THE CM/GC AND INCLUDED AS A PROJECT 6. PROVIDE EACH IDF ROOM WITH: DOCUMENT. ANY REFERENCES TO PHASING OR TEMPORARY SYSTEMS ON THESE DOCUMENTS ARE FOR REFERENCE ONLY AND a. ONE L6-30R FED FROM A STANDBY PANEL MOUNTED TO THE ARE INTENDED TO AID IN GENERAL COORDINATION BETWEEN THE TOP OF EACH RACK[QTY. OF 2] DESIGN TEAM AND THE CONTRACTING TEAM. NO SUCH REFERENCES 9000 SW DURHAM RD. TO PHASING OR TEMPORARY PROVISIONS ON THESE DOCUMENTS TIGARD, OR. 97224 b. TWO NORMALLY POWERED WALL MOUNTED QAUDPLEX THAT ARE IN CONFLICT WITH THE DETAILS OF THE"PHASING PLAN" RECEPTACLES. DOCUMENT SHALL BE USED AS LEVERAGE FOR CHANGER ORDERS JOB N0: 16992.00 DURING CONSTRUCTION. ISSUE DATE: 04/18/2018 7. PROVIDE EACH OFFICE WITH: Jurisdiction Stamp Area a. ONE QUADPLEX FOR EACH COMPUTER WORK STATION b. TWO DUPLEX RECEPTACLES 8. PROVIDE EACH CONFERENCE ROOM WITH: a. ONE FLOORBOX/POKE-THRU WITH A QUADPLEX RECEPTACLE Z MOUNTED BELOW THE CONFERENCE TABLE b. ONE DUPLEX RECEPTACLE FOR WALL MOUNTED DISPLAY W MONITOR z BASIS O F DESIGN c. TWO WALL MOUNTED DUPLEX RECEPTACLES Uj 9. PROVIDE EACH CLASSROOM WITH: AND NOTES Uj a. TWO WALL MOUNTED DUPLEX RECEPTACLES FOR WALL ij- MOUNTED PROJECTOR DISPLAY W b. TWO WALL MOUNTED CONVENIENCE DUPLEX RECEPTACLES ON EACH WALL o E0 . 02 -� c. ONE CEILING MOUNTED DUPLEX RECEPTACLE PROJECTOR COPPER FEEDER SCHEDULE BRANCH CIRCUIT SCHEDULE bassetti FEEDER CONDUITS CONDUCTORS PER SET NOTES FEEDER CONDUITS CONDUCTORS PER SET NOTES CIRCUIT CONDUITS CONDUCTORS PER SET WIRING NOTES architects TAG MET SETS RNC PHASE/NEUTRAL GROUND TAG MET SETS RNC PHASE/NEUTRAL GROUND TAG MET SETS RNC PHASE/NEUTRAL GROUND CONFIG. 4000.4 3.50" 11 4.00" (4)500 KCMIL 500 KCMIL - 250.4 2.50" 1 3.00" (4) 250 KCMIL #4 - (JOND 0.75" 1 1.00" (2)#6, (1)#6N #10 1,2W,N 4000.3 3.00" 11 4.00" _ �� _ _ 721 NW 9TH Ave, Suite 350 (3)500 KCMIL 500 KCMIL 250.3 2.50 1 3.00 (3)250 KCMIL #4 60.2 0.75" 1 1.00" (2)#6 #10 t,2W Portland, Oregon 97209 3500.4 3.50" 10 4.00" (4)500 KCMIL 500 KCMIL - 225.4 2.50" 1 3.00" (4)#4/0 #4 - (IRO 0.75" 1 1.00" (1)#6, (1)#6N #10 1P,lW,N _ T (206) 340 9500 F (206) 340 9519 3500.3 3.00" 10 4.00" (3)500 KCMIL 500 KCMIL - 225.3 2.00" 1 2.50" (3)#4/0 #4 - 50.2N 0.75" 1 1.00" (2)#6, (1)#6N #10 1U,2W,N 3000.4 3.50" 8 4.00" (4)500 KCMIL 400 KCMIL - 200.4 2.00" 1 2.50" (4)#3/0 #6 - 50.2 0.75" 1 1.00" (2)#6 #10 t,2W _ CIVIL ENGINEER & LANDSCAPE 3000.3 3.00" 8 4.00" (3)500 KCMIL 400 KCMIL - 200.3 2.00" 1 2.50" (3)#3/0 #6 - 50.1 0.75" 1 1.00" (1)#6, (1)#6N #10 11,1W,N _ Cardno 6720 SW Macadam Ave Suite 200, 2500.4 3.50" 7 4.00" (4)500 KCMIL 350 KCMIL - 175.4 2.00" 1 2.50" (4)#2/0 #6 - 40.2N 0.75" 1 1.00" (2)#8, (1)#8N #10 1U,2W,N Portland, OR 97219 T(503)-419-2500 2500.3 3.00" 7 4.00" (3) 500 KCMIL 350 KCMIL - 175.3 1.50" 1 2.00" (3)#2/0 #6 - 40.2 0.75" 1 1.00" (2)#8 #10 1D,2W _ STRUCTURAL ENGINEER 2000.4 3.00" 6 4.00" (4)400 KCMIL 250 KCMIL - 150.4 2.00" 1 2.00" (4)#1/0 #6 - 40.1 0.75" 1 1.00" (1)#8, (1)#8N #10 1U,lW,N - Catena Engineers 2000.3 3.00" 6 4.00" (3)400 KCMIL 250 KCMIL - 150.3 1.50" 1 2.00" (3)#1/0 #6 - 30.2N 0.75" 1 1.00" (2)#10, (1)#1 ON #10 10,2W,N 1500 NE Irving St., Suite 412 Portland, OR 97232 1600.4 3.00" 5 4.00" (4)400 KCMIL #410 - 125.4 1.50" 1 1.50" (4)#1 #6 - 30.2 0.75" 1 1.00" (2)#10 #10 V,2W _ T(503)-467-4980 1600.3 3.00" 5 4.00" (3)400 KCMIL #4/0 - 125.3 1.25" 1 1.50" (3)#1 #6 - 30.1 0.75" 1 1.00" (1)#10, (1)#1 ON #10 1n,lW,N _ MECHANICAL ELECTRICAL & PLUMBING ENGINEER 1200.4 3.00" 4 4.00" (4)350 KCMIL #310 - 110.4 1.25" 1 1.50" (4)#2 #6 - 20.2N 0.50" 1 1.00" (2)#12, (1)#12N #12 10,2W,N 7,8 Glumac 1200.3 3.00" 4 3.00" (3)350 KCMIL #310 - 110.3 1.25" 1 1.50" (3)#2 #6 - 20.2 0.50" 1 1.00" (2)#12 #12 10,2W 7,8 900 SW Fifth Ave., Suite 1600 Portland, OR 97204 1000.4 3.00" 3 4.00" (4)400 KCMIL #2/0 - 100.4 1.25" 1 1.50" (4)#2 #8 - 20.1 0.50" 1 1.00" (1)#12, (1)#12N #12 10,1W,N 7,8 T(503)-227-5280 1000.3 3.00" 3 4.00" (3)400 KCMIL #2/0 - C16ffD 1.25" 1 1.50" (3)#2 #8 - FOOD SERVICE CONSULTANT NOTES: Webb Foodservice Design 800.4 3.00" 3 3.00" (4)300 KCMIL #1/0 - 90.4 1.25" 1 1.50" (4)#2 #8 - 1. CONDUCTORS AND CONDUITS SHOWN IN THIS SCHEDULE ARE BASED ON COPPER CONDUCTORS 3700 SE Lafayette Ct. 800.3 2.50" 3 3.00" _ WITH THHN/THWN INSULATION. Portland, OR 97202 (3) 300 KCMIL #110 90.3 1.25 1 1.50 (3)#2 #8 2. THIS SCHEDULE SHALL BE USED ON ALL BRANCH CIRCUITS SERVING LOADS WHERE THE CIRCUIT T(503)-236-8566 700.4 3.50" 2 4.00" (4)500 KCMIL #1/0 - 80.4 1.25" 1 1.50" (4)#4 #8 _ BREAKER SIZE MATCHES THE AMPACITY OF ITS FEEDER. USE THE"MOTOR CIRCUIT SCHEDULE" FOR LOADS, SUCH AS MOTORS, PUMPS, FANS, CHILLERS, ETC.,WHERE THE CIRCUIT BREAKER SIZE ACOUSTIC & AV CONSULTANT 700.3 3.00" 2 4.00" (3) 500 KCMIL #1/0 - 80.3 1.00" 1 1.50" (3)#4 #8 - IS LARGER THAN THE AMPACITY OF ITS FEEDER. The Greenbusch Group 3. PROVIDE GROUND WIRE NOTED ABOVE IN ALL BRANCH CIRCUITS. 1900 W. Nickerson St., Suite 201 600.4 3.00" 2 4.00" (4) 350 KCMIL #1 - 70.4 1.25" 1 1.50" (4)#4 #8 - 4. NOT ALL BRANCH CIRCUITS SHOWN ABOVE ARE NECESSARILY USED ON THIS PROJECT. Seattle,WA 98119 5. "MET"= EMT, IMC, GRC, RAC, OR PVC COATED GRC TYPE CONDUITS. "RNC"= PVC 40, PVC 80 OR T 206-378-0569 600.3 2.50" 2 3.00" (3)350 KCMIL #1 - 70.3 1.00" 1 1.50" (3)#4 #8 - FIBERGLASS TYPE CONDUITS ROUTED UNDERGROUND. REFER TO SIZING ON DRAWINGS IF"RNC" 500.4 2.50" 2 3.00" (4)250 KCMIL #2 - 60.4 1.00" 1 1.00" (4)#6 #10 - CONDUITS ARE ROUTED ABOVEGROUND. CONDUIT SIZES NOTED ON SINGLE-LINE DIAGRAM OR ON COST CONSULTANT PLANS SUPERSEDE SIZES NOTED ABOVE IF LARGER. Construction Focus 500.3 2.50" 2 2.50" (3) 250 KCMIL #2 - 60.3 0.75" 1 1.00" (3)#6 #10 - 6. THIS SCHEDULE APPLIES TO STANDARD LENGTH CIRCUITS ONLY. CONTRACTOR TO UPSIZE WIRING 740 Almaden St. AS REQUIRED TO MEET MINIMUM VOLTAGE DROP REQUIREMENTS INDICATED IN SPECIFICATIONS. Eugene, OR 97402 450.4 2.50" 2 3.00" (4)#4/0 #2 - 50.4 1.00" 1 1.00" (4)#6 #10 - GROUND CONDUCTOR WILL ALSO NEED TO BE INCREASED PROPORTIONATELY AS REQUIRED BY T 541-686-2031 450.3 2.00" 2 2.50" (3)#4/0 #2 - 50.3 0.75" 1 1.00" (3)#6 #10 - NEC. 7. THESE BRANCH CIRCUITS TAGS ARE TYPICALLY NOT SHOWN ON PLANS FOR CLARITY REASONS. 400.4 2.00" 2 2.50" (4)#3/0 #2 - 40.4 0.75" 1 1.00" (4)#8 #10 - CONTRACTOR SHALL USE THIS INFORMATION AS IT APPLIES FOR ALL CONDUITS CONTAINING ONE 400.3 2.00" 2 2.50" (3)3/0 #2 - 40.3 0.75" 1 1.00" (3)#8 #10 _ OR MORE 20A/1 P CIRCUITS. 8. CONTRACTOR MAY COMBINE 20A 1 AND 2-POLE CIRCUITS, UP TO A MAXIMUM OF(3) PHASE 350.4 3.50" 1 4.00" (4) 500 KCMIL #2 - 30.4 0.75" 1 1.00" (4)#10 #10 - CONDUCTORS, IN ONE CONDUIT.ALL 3-PHASE AND CIRCUITS LARGER THAN 20A SHALL BE IN DEDICATED CONDUITS, UON. PROVIDE DEDICATED NEUTRALS FOR EACH 1-POLE CIRCUIT. 350.3 2.50" 1 4.00" (3)500 KCMIL #2 - 30.3 0.75" 1 1.00" (3)#10 #10 - 9. ALL HOMERUNS SHALL USE 0.75"CONDUIT SIZE MINIMUM. 300.4 3.00" 1 3.00" (4) 350 KCMIL #4 - 20.4 0.75" 1 1.00" (4)#12 #12 - 300.3 2.50" 1 3.00" (3) 350 KCMIL #4 - 20.3 0.75" 1 1.00" (3)#12 #12 - O 7 XFR 8 MOTOR CIRCUIT SCHEDULE SCHD 9 FEEDER CONDUITS1� CONDUCTORS PER SET NOTES NOTES: TAG MET SETS RNC PHASE/NEUTRAL GROUND(j) 1. CONDUCTORS AND CONDUITS SHOWN IN THIS SCHEDULE ARE BASED ON COPPER CONDUCTORS WITH THHN/THWN INSULATION. 2. THIS SCHEDULE SHALL BE USED ON ALL FEEDERS SERVING LOADS WHERE THE CIRCUIT BREAKER SIZE MATCHES THE AMPACITY OF ITS FEEDER. USE THE"MOTOR CIRCUIT 800.3M 3.00" 2 4.00" (3)500 KCMIL #1/0 - SCHEDULE" FOR LOADS, SUCH AS MOTORS, PUMPS, FANS, CHILLERS, ETC.,WHERE THE CIRCUIT BREAKER SIZE IS LARGER THAN THE AMPACITY OF ITS FEEDER. 3. PROVIDE GROUND WIRE NOTED ABOVE IN ALL FEEDERS AND BRANCH CIRCUITS,WHERE MULTIPLE CONDUITS ARE INDICATED PROVIDE NOTED GROUND WIRE IN EACH CONDUIT. 700.3M 3.00" 2 3.00" (3)400 KCMIL #1l0 - 4. NOT ALL FEEDERS ARE NECESSARILY USED ON THIS PROJECT. 600.3M 2.50" 2 3.00" (3) 350 KCMIL #1 - 5. NOMINAL AMPACITIES GREATER THAN 100 AMPS ARE FOR 75 DEG..0 TERMINALS. 6. "MET"= EMT, IMC, GRC, RAC, OR PVC COATED GRC TYPE CONDUITS. "RNC"= PVC 40, PVC 80 OR FIBERGLASS TYPE CONDUITS ROUTED UNDERGROUND. REFER TO SIZING ON DRAWINGS 500.3M 2.50" 2 2.50" (3)250 KCMIL #2 IF "RNC"CONDUITS ARE ROUTED ABOVEGROUND. CONDUIT SIZES NOTED ON SINGLE-LINE DIAGRAM OR ON PLANS SUPERSEDE SIZES NOTED ABOVE IF LARGER. 7. OVERSIZED(173%MIN.) NEUTRAL FOR FEEDERS CONNECTED TO A K-4 OR HIGHER RATED TRANSFORMER. 450.3M 2.00" 2 2.00" (3)#4/0 #2 - 8. REFER TO TRANSFORMER SCHEDULE FOR STANDARD PRIMARY AND SECONDARY FEEDER SIZES. 400.3M 3.00" 1 4.00" (3)500 KCMIL #2 - 9. REFER TO MCC OR PANEL SCHEDULES FOR FEEDER SIZES TO EQUIPMENT NOTED WITH THIS TAG. 350.3M 3.00" 1 3.00" (3)400 KCMIL #2 - 300.3M 2.50" 1 3.00" (3)350 KCMIL #4 - 250.3M 2.50" 1 2.50" (3)250 KCMIL #4 - 225.3M 2.00" 1 2.00" (3)#4/0 #4 - 200.3M 2.00" 1 2.00" (3)#3/0 #6 - 175.3M 1.50" 1 2.00" (3)#2/0 #6 - 150.3M 1.50" 1 1.50" (3)#1/0 #6 - TRANSFORMER SCHEDULE 125.3M 1.25" 1 1.50" (3)#2 #6 480V PRIMARY 480Y/277V SECONDARY 208Y/120V SECONDARY 110.3M 1.25" 1 1.50" (3)#2 #6 - KVA WEIGHT 100.3M 1.00" 1 1.50" (3)#4 #8 - C.B. FEEDER C.B. FEEDER GND C.B. FEEDER GND 4 DATE 15 30/3 C"D 30/3 CX4D #8 50/3 CKU #8 275 90.3M 1.00" 1 1.50" (3)#4 #8 - 30 50/3 CRED 50/3 C3RD #8 100/3 110.4 #8 340 80.3M 1.00" 1 1.50" (3)#4 #8 - 45 70/3 70.3 70/3 C70.4 #6 150/3 150.4 #6 475 70.3M 0.75" 1 1.00" (3)#6 #8 - 75 125/3 C125.3 125/3 125.4 #2 225/3 225.4 #2 1060 60.3M 0.75" 1 1.00" (3)#8 #10 - 50.3M 0.75" 1 1.00" (3)#10 #10 - 112.5 175/3 CMD 175/3 175.4 #1/0 400/3 400.4 #1/0 1250 40.3M 0.75" 1 1.00" (3)#10 #10 - 150 225/3 225.3 225/3 225.4 #2/0 500/3 500.4 #2/0 2130 30.3M 0.75" 1 1.00" (3)#12 #10 - 225 350/3 350.3 350/3 350.4 #3/0 800/3 C800.4 #3/0 2665 CkWD 0.75" 1 1.00" 1 (3)#12 #12 1 - 300 450/3 450.3 450/3 450.4 #3/0 1000/3 1000.4 #3/0 4190 GENERAL NOTES: 500 800/3 COUD 800/3 Co00.4 #4/0 1600/3 1600.4 #4/0 3480 1. THE NUMBER PORTION BEFORE THE PERIOD IS THE AMPACITY OF THE BREAKER 750 1200/31200.3 1200/3 1200.4 #4/0 2500/3 2500.4 #4/0 3710 SERVING THE MOTOR LOAD, NOT THE AMPACITY OF THE FEEDER. 2. CONDUCTORS AND CONDUITS SHOWN IN THIS SCHEDULE ARE BASED ON COPPER TIGARD TUALATIN SCHOOL DISTRICT NOTES: CONDUCTORS WITH THHN/THWN INSULATION. 1. THIS SCHEDULE APPLIES TO 3-PHASE,480:480Y/277V AND 480:208Y/120V DRY-TYPE STEP-DOWN TRANSFORMERS ONLY. 3. THIS MOTOR BRANCH CIRCUIT SCHEDULE SHALL BE USED FOR ALL CIRCUITS TIGARD HIGH 2. ON ONE-LINE DIAGRAMS AND SCHEDULES WHERE FEEDERS AND CIRCUIT BREAKERS ARE SHOWN AS"XFR", PROVIDE RESPECTIVE FEEDERS,GROUND WHERE THE CIRCUIT BREAKER SIZE PROTECTING THE LOAD IS LARGER THAN THE CONDUCTORS AND BREAKERS NOTED ABOVE. PROVIDE SECONDARY BREAKER NOTED ABOVE AS MAIN CIRCUIT BREAKER INTEGRAL IN DISTRIBUTION, PANEL AND AMPACITY OF THE CIRCUIT CONDUCTORS. EXAMPLES ARE: MOTORS, CHILLERS, SCHOOL SWITCH BOARDS, UON. ELEVATORS, FANS, PUMPS, ETC. 3. GROUND CONDUCTOR SIZES INDICATED ABOVE SUPERSEDE GROUND CONDUCTORS SHOWN ON FEEDER SCHEDULE. ROUTE COPPER GROUNDING CONDUCTOR 4. PROVIDE GROUND WIRE NOTED ABOVE IN ALL CONDUITS.WHERE MULTIPLE TO GROUNDING ELECTRODE PER NEC. PROVIDE BONDING ALSO PER NEC.COMMON LEAD OF LARGEST REQUIRED SIZE MAY BE EMPLOYED TO SERVE MULTIPLE CONDUITS ARE INDICATED PROVIDE NOTED GROUND WIRE IN EACH CONDUIT. MODERNIZATION TRANSFORMERS. 5. NOT ALL FEEDERS ARE NECESSARILY USED ON THIS PROJECT. 4. NOT ALL TRANSFORMER SIZES INDICATED IN THIS SCHEDULE ARE NECESSARILY USED ON THIS PROJECT. 6. NOMINAL AMPACITIES GREATER THAN 100 AMPS ARE FOR 75 DEG. C.TERMINALS. 5. WEIGHTS INDICATED ABOVE ARE APPROXIMATE,ACTUAL VALUES MAY VARY. CONFIRM WITH SUBMITTAL INFO. KEYED NOTES: 1. "MET"= EMT, IMC, GRC, RAC, OR PVC COATED GRC TYPE CONDUITS. "RNC"= PVC 40, PVC 80 OR FIBERGLASS TYPE CONDUITS ROUTED UNDERGROUND. REFER TO SIZING ON DRAWINGS IF"RNC"CONDUITS ARE ROUTED ABOVEGROUND. CONDUIT SIZES 9000 SW DURHAM RD. NOTED ON SINGLE-LINE DIAGRAM OR ON PLANS SUPERSEDE SIZES NOTED ABOVE IF TIGARD, OR. 97224 LARGER. JOB NO: 16992.00 2. TERMINATIONS. ON CIRCUITS SHOWN WITH A".6M"SUFFIX, PROVIDE SIX PHASE CONDUCTORS AND ONE GROUND WIRE IN CODE SIZED CONDUIT. INCLUDE 80% ISSUE DATE: 04/18/2018 DERATING FACTOR ON PHASE CONDUCTOR SIZE. Jurisdiction Stamp Area EXPIRES: 12/31/19 PRO Ffsf, ANG I N f F4' 0_ 757 7PE 9 � OREGON .� N T. BLIP REFERENCE '_ TABLES 0 w E0 . 03 SHEET NOTES KEYED NOTES (::#:) o A. A SUBSTANTIAL PORTION OF THE EXISTING FACILITY IS 1 EXISTING SUB-DISTRIBUTION PANEL SDP-SDC TO bassetti TO BE DEMOLISHED. HATCHED AREAS OF THE FACILITY REMAIN, BUT DUE TO DEMOLITION AND NEW ARE PORTIONS THAT ARE TO REMAIN. CONSTRUCTION SCOPE,THE FEEDER WILL BE architects INTERRUPTED. MAINTAIN EXISTING UPSTREAM B. FOR AREAS BEING DEMOLISHED, CONTRACTOR SHALL CONNECTION TO EXISTING MAIN SWITCHBOARD. REFER REMOVE ALL EXISTING EQUIPMENT, DEVICES, RACEWAY, TO SHEET E1.12 FOR MORE INFORMATION. AND OTHER COMPONENTS THAT TYPICALLY BELONGS 721 NW 9TH Ave, Suite 350 TO DIVISION 26, DIVISION 27, AND DIVISION 28. 2 EXISTING SUB-DISTRIBUTION PANEL SDP-SDB. PANEL TO Portland, Oregon 97209 BE REPLACED DURING CONSTRUCTION PHASE, AND T (206) 340 9500 F (206) 340 9519 C. WHERE DEMOLISHED POWER EQUIPMENT IS FED FROM RE-FED FROM A NEW SOURCE. REMOVE PANEL AND UPSTREAM SOURCES IN AREAS TO REMAIN, REMOVE EXISTING FEEDER DURING DEMOLITION PHASE. THE FEEDER IN THE DEMOLISHED AREA. SAFE-OFF CONDUCTORS AND CAP RACEWAYS AT THE PORTION OF 3 EXISTING TRANSFORMER WITH POOR PERFORMANCE CIVIL ENGINEER & LANDSCAPE THE BUILDING THAT IS TO REMAIN EXISTING. DUE TO AGE. TRANSFORMER TO BE REPLACED DURING Cardno DISCONNECT AND SAFE-OFF CONDUCTORS AT THE THE CONSTRUCTION PHASE. REMOVE DURING 6720 SW Macadam Ave Suite 200, UPSTREAM POWER SOURCE ALSO. DEMOLITION PHASE. Portland, OR 97219 T(503)-419-2500 4 EXISTING MDF ROOM TO BE RELOCATED TO NEW STRUCTURAL ENGINEER LOCATION. CABLING CURRENTLY TERMINATED IN THE MDF ROOM THAT SUPPORTS NETWORK CONNECTIVITY Catena Engineers TO AREAS EITHER OUTSIDE OF THE SCOPE OF WORK, 1500 NE Irving St., Suite 412 OR AREAS THAT NEED TO REMAIN CONNECTED DURING Portland, OR 97232 DEMO AND PHASE 1 WORK,TO BE RE-ROUTED AND T(503)-467-4980 RE-TERMINATED WITHIN THE NEW MDF LOCATION PRIOR MECHANICAL ELECTRICAL & TO DEMO AND PHASE 1 WORK.ASSUME(12) 12-STRAND PLUMBING ENGINEER FIBER OPTIC CABLES,AND(100)CATEGORY 6 CABLES Glumac 1 FOR BUDGETARY PURPOSES. 900 SW Fifth Ave., Suite 1600 Portland, OR 97204 5 EXISTING DISTRIBUTION FOR WIRING TO PAGING T(503)-227-5280 SPEAKERS IS LOCATED HERE. WIRING THAT FOOD SERVICE CONSULTANT TERMINATES AT THIS LOCATION, THAT SUPPORTS PAGING SPEAKERS OUTSIDE OF THE SCOPE OF WORK Webb Foodservice Design THAT IS EXISTING TO REMAIN, TO BE RE-ROUTED, 3700 SE Lafayette Ct. SPLICED, AS NECESSARY TO RELOCATE TO THE NEW Portland, OR 97202 MDF LOCATION. T(503)-236-8566 ACOUSTIC &AV CONSULTANT The Greenbusch Group 1900 W. Nickerson St., Suite 201 Seattle,WA 98119 T 206-378-0569 COST CONSULTANT Construction Focus 740 Almaden St. Eugene, OR 97402 0 T 541-686-2031 C, i 0 0 0 0 0 0 0 0 0 i O U o O O ° EXISTING MAIN o ELECTRICAL ROOM PNL-4H PNL- 2LC PNL-2LA PNL- 5 (SA PNL-E ❑ • I�T 4 PNL-XF PNL-SDA SB — — — — — — o PNL-XA I I I I I I I I FF- SF . o CN 17 --- I I _ 4/04/18 A BP2 ADD#1 ODATE I I SL — — — — — — — — N I I I SM — — — — — — — — — I I I I p 3 I I I 2 TIGARD TUALATIN SCHOOL DISTRICT TIGARD HIGH I I SCHOOL SQ MODERNIZATION 1 I I I I 9000 SW DURHAM RD. TIGARD, OR. 97224 JOB NO: 16992.00 ISSUE DATE: 04/18/2018 Jurisdiction Stamp Area S 1 CS—KS- z S5 S6 S7 S9 �S10iS11) (S13) 0 w C) DEMO PLAN - ELECTRICAL MAIN LEVEL MAIN FLOOR - FLOOR PLAN - POWER AND SIGNAL DEMOLITION PROJECT NORTH N TRUE CK 1 SCALE: 1/32" = 1'-0" NORTH � ED1 . 12 1/32" = V-0" 0 LL 0 32'-0" 64'-0" 96'-0" 128'-0" i a0coe0 architects il 721 NW 9TH Ave, Suite 350 Portland, Oregon 97209 T (206) 340 9500 F (206) 340 9519 CIVIL ENGINEER & LANDSCAPE Cardno 6720 SW Macadam Ave Suite 200, Portland, OR 97219 T(503)-419-2500 STRUCTURAL ENGINEER Catena Engineers 1500 NE Irving St., Suite 412 Portland, OR 97232 T(503)-467-4980 MECHANICAL ELECTRICAL & PLUMBING ENGINEER Glumac 900 SW Fifth Ave., Suite 1600 Portland, OR 97204 T(503)-227-5280 FOOD SERVICE CONSULTANT Webb Foodservice Design 3700 SE Lafayette Ct. Portland, OR 97202 T(503)-236-8566 ACOUSTIC &AV CONSULTANT The Greenbusch Group 1900 W. Nickerson St., Suite 201 Seattle,WA 98119 T 206-378-0569 COST CONSULTANT Construction Focus 740 Almaden St. Eugene, OR 97402 T 541-686-2031 SINGLE-GANG MUD-RING OR DOUBLE-GANG AS REQUIRED ON FLOOR PLAN 0 0 0 0 (/p l F�0 MOUNTING BRACKET BY CADDY OR EQUAL ADATE NOTE: THIS DETAIL APPLIES FOR ALL SITUATIONS WHERE TWO OR MORE POWER AND TELECOM DEVICES ARE SHOWN ON THE DRAWINGS, UON. POWER/TELECOM DEVICE BOX INSTALLATION N N1 5 SCALE: NONE S1 E1 E2 12"MIN. 2 1NOTE:A L DEVICES INDICATED TO BE INSTALLED AT DIFFERENT MOUNTING HEIGHTS AND LOCATED WITHIN SAME TIGARD TUALATIN SCHOOL DISTRICT STUD SPACE SHALL ALIGN VERTICALLY, ON THE SAME SIDE OF THE STUD.WHERE TIGARD H ,�\ $ WALL MOUNTED TELEPHONES OCCUR FACP OVER LIGHT SWITCHES,VOLUME CONTROLS, ETC. OFFSET ONE STUD SCHOOL FSA 82" SPACE 901, 66" 2" BETWEEN MODERNIZATION BOXES TYP. 6'-6" TO TOP TO TOP OF BOXES CABINET OF I 4 L S F ]4 Q W W W 9000 SW DURHAM RD. TIGARD, OR. 97224 I(P1P(PVov JOB NO: 16992.00 ABOVE COUNTER(SAD) 4 48" 4 ��o��� 4 ISSUE DATE: 04/18/2018 �(P ® I f I Jurisdiction Stamp Area 20" EXPIRES: 12/31/19 n PROFFs FINISHED FLOOR � GINE 'fO NOTES: 757 7PE A. HEIGHTS SHOWN ARE TYPICAL TO TOP OF BOX, UNLESS OTHERWISE NOTED. B. WHERE EVER DEVICES ARE INDICATED TO BE ABOVE DOORS, DEVICE SHALL BE CENTERED VERTICALLY o�OREGON BETWEEN TOP OF DOOR TRIM AND CEILING LINE AND CENTERED HORIZONTALLY ON DOOR OPENING, �� � 9� �tinP J~ UNLESS OTHERWISE NOTED. �Fi� T B01p'�O C. MOUNTING HEIGHTS SHOWN ON ARCHITECTURAL ELEVATIONS SHALL GOVERN OVER THOSE SHOWN ABOVE, CONTRACTOR SHALL ALWAYS REFER TO ARCHITECTURAL DRAWINGS PRIOR TO INSTALLING J- BOXES AND BACKBOXES. INFORM ENGINEER AND ARCHITECT OF CONFLICTS. ELECTRICAL D. DO NOT MOUNT THERMOSTATS OR TEMPERATURE SENSORS ABOVE DIMMERS. INFORM ENGINEER OF CONFLICTS. U_ DETAILS ELECTRICAL TELECOM & SIGNAL SYS. DEVICE MOUNTING 0 HEIGHTS & ALIGN. 4 SCALE: NONE F ry E9 . 04 bassettil architects 721 NW 9TH Ave, Suite 350 Portland, Oregon 97209 T (206) 340 9500 F (206) 340 9519 CIVIL ENGINEER & LANDSCAPE Cardno 6720 SW Macadam Ave Suite 200, Portland, OR 97219 T(503)-419-2500 STRUCTURAL ENGINEER Catena Engineers 1500 NE Irving St., Suite 412 Portland, OR 97232 T(503)-467-4980 MECHANICAL ELECTRICAL & PLUMBING ENGINEER Glumac 900 SW Fifth Ave., Suite 1600 Portland, OR 97204 T(503)-227-5280 FOOD SERVICE CONSULTANT Webb Foodservice Design 3700 SE Lafayette Ct. Portland, OR 97202 T(503)-236-8566 ACOUSTIC & AV CONSULTANT The Greenbusch Group 1900 W. Nickerson St., Suite 201 USE"BOLD"STYLE TEXT Seattle,WA 98119 T 206-378-0569 WIDTH AS REQUIRED, MIN 4" COST CONSULTANT Construction Focus 1/2" 740 Almaden St. Eugene, OR 97402 EXHAUST FAN EF-1 K7 1/4" T 541-686-2031 2 (D FED FROM DS1A1 (D 3/16" 3/16" 10 HP., 480V, 3PH 3/16 1/2" 4/ USE RIVOTS ON DIV. 16 PROVIDED ITEMS IN EXTERIOR LOCATIONS, USE DOUBLE-STICK TAPE ON OWNER FURNISHED ITEMS(DO NOT DRILL HOLES)AND INTERIOR EQUIPMENT GENERAL EQUIPMENT USE RIVETS NOT DOUBLE-STICK TAPE WIDTH AS REQUIRED, MIN 3.5" FOR EXTERIOR LOCATIONS ONLY USE"BOLD"STYLE TEXT m m WIDTH AS REQUIRED, MIN. 5" EXHAUST FAN EF-1 1/4" 1" 1ST FLOOR-COL. A3 3116"3116" 1/4" 3116" P NEL 2N6.2 1/4" LINE 1 LOCATION OF LOAD 1/411 DESCRIPTION OF LOAD SERVED LIFE SAFETY SYSTEM 3/16" LINE 2 1/4" CIRCUIT BREAKERS IN DIST. PANELS 2.5 FED FROM SDP 3116" LINE 3 -BN_ 1/4" NOTES: 1. SEE DRAWINGS FOR ADDITIONAL NAMEPLATE INFORMATION AND COLORS 4OO MCB, 480V, 3PH, 3W 3/16" LINE 4 OF NAMEPLATES FOR DIFFERENT SYSTEMS. 1/4" 65,000 AIC 3/16" LINE 5 2. TEXT SHOWN ABOVE IS FOR EXAMPLE ONLY. MODIFY TEXT AS REQUIRED 1/4" TO MATCH EQUIPMENT SPECIFICATIONS. 3. CENTER ALL TEXT HORIZONTALLY MAIN BUS SIZE IF MAIN LUGS ONLY OR TRIP RATING OF MAIN BREAKER CENTERLINE OF INNER DOOR (OPTION#1) EQUIPMENT IDENTIFICATION NAMEPLATES (OPTION FOUTER DOOR NAMEPLATE MOUNTING LOCATION 7 (OPTION#2) — NOTES SCALE: NONE 1. SEE DRAWINGS FOR ADDITIONAL NAMEPLATE INFORMATION AND COLORS OF NAMEPLATES FOR DIFFERENT SYSTEMS. 2. PROVIDE ONE NAMEPLATE FOR EACH PANEL OR MCC SECTION.WHERE SECTION NUMBER TWO AND ABOVE ARE WITHIN —_ SAME ROOM AND WITHIN 10'OF EACH OTHER SMALLER SIZE NAMEPLATE CAN BE USED. # DATE 3. CENTER ALL TEXT HORIZONTALLY. 4. TEXT SHOWN ABOVE IS FOR EXAMPLE ONLY. MODIFY TEXT AS REQUIRED TO MATCH EQUIPMENT SPECIFICATIONS N 5. DRILL HOLES ON EXTERIOR NAMEPLATES ONLY. ON LOW VOLTAGE SWITCHES 6. PROVIDE TYPED PANEL SCHEDULES IN DOOR SLEEVES FOR ALL PANELS. INDICATE LOAD DISCRIPTION AND BREAKER. N N 1 TYPICAL CIRCUIT IDENTIFICATION: ENGRAVED TEXT ON SELF-ADHESIVE 7. NAMEPLATES ARE NOT REQUIRED FOR APARTMENT AND CONDO PANELS. COVERPLATE WHEN PERMANENT TAPE WITH 12 PROVIDE PANEL AND CIRCUIT REQUIRED BY POINT HELVETICA MEDIUM NUMBERS AS WELL AS RELAY S1 El SPECIFICATIONS OR LETTERING LETTER(S)SHOWN ON FLOOR E2 WHEN NOTED CIRCUIT NUMBER PLAN THAT ARE CONTROLLED 1 \ BY THAT SWITCH POWER & LIGHTING PANEL NAMEPLATES S72 PANEL NAME 2 SCALE: NONE EXHAUST FAN XXXXX-XX TIGARD TUALATIN SCHOOL DISTRICT � o TIGARD HIGH ° SCHOOL 0 MODERNIZATION � o ° 9000 SW DURHAM RD. 0 0 TIGARD, OR. 97224 JOB NO:—XXXXX-XX X�-XX(A,B) 169 0 ISSUE DATE. 04/18/2018 SPECIALTY DEVICE RECEPTACLES LIGHT SWITCHES Jurisdiction Stamp Area OR SWITCH EXPIRES: 12/31/19 PRO FF r NOTES: DEFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION AND COLORS OF TAPE REQUIRED FOR �No Nf E � 757 7P DIFFERENT SYSTEMS. 2. TEXT SHOWN ABOVE IS FOR EXAMPLE ONLY. MODIFY TEXT AS REQUIRED TO MATCH INSTALLATION. ���OREGONo� 3. LABEL DEVICES IN SURFACE METAL RACEWAYS, POWER POLES, FLOOR BOXES, CONCEALED MULTI- FN T. B0P� SERVICE POWER BOXES, ETC. SIMILARLY. 4. WHERE MULTIPLE SWITCHES ARE GROUPED UNDER COMMON COVERPLATE AND ARE SERVED ELECTRICAL FROM SAME CIRCUIT, PROVIDE ONLY ONE LABEL FOR MIDDLE SWITCH. PROVIDE MULTIPLE LABELS IF DIFFERENT CIRCUITS ARE USED. 0 DETAILS 5. LABELS ARE NOT REQUIRED FOR DEVICES IN APARTMENTS AND CONDOS. G DEVICE & SWITCH LABELING 6 SCALE: NONE W E9 . 06 BASIS OF DESIGN ELECTRICAL NOTES POWER NOTES DEMOLITION NOTES 1. PURPOSE: 1. THE CIRCUITING SHOWN IS DIAGRAMMATIC.THE DRAFTING METHOD 1. WHERE POSSIBLE, BOXES SHALL BE IN SEPARATE STUD SPACES FROM 1. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR REVIEWING bassetti WHICH MOST SIMPLY CONVEYS THE CIRCUITING INTENT AT A GIVEN BOXES SERVING OTHER ROOMS TO MINIMIZE SOUND TRANSFER. ARCHITECTURAL DEMOLITION PLANS. FOR WALLS, SOFFITS, CASEWORK, architects A. THIS BASIS OF DESIGN NARRATIVE IS INTENDED TO BE USED TO SET LOCATION IS EMPLOYED. ISLANDS, CEILINGS, ETC. SHOWN TO BE DEMOLISHED, REMOVE THE THE BASIS OF UNDERSTANDING OF THE PROJECT SCOPE BETWEEN 2. COORDINATE EXACT MECHANICAL EQUIPMENT LOCATIONS AND FOLLOWING: THE OWNER AND THE ASSOCIATED DESIGN PROFESSIONALS,AND TO 2. REFER TO ONE LINE DIAGRAM FOR ADDITIONAL INFORMATION ON NAMED REQUIREMENTS WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN. COMMUNICATE TO THE CONTRACTORS THAT SCOPE OF WORK. IT ELECTRICAL EQUIPMENT SHOWN. COORDINATE CONDUIT REQUIREMENTS FOR ALL HVAC EQUIPMENT WITH A. TELECOM OUTLET BOXES AND RACEWAYS, COORDINATE CABLE 721 NW 9th Ave, Suite 350 SHALL ALSO BE CONSIDERED BINDING IN THE SAME MANNER AS THE CONTROLS CONTRACTOR. REMOVAL WITH GENERAL CONTRACTOR AND OWNER. Portland, Oregon 97209 DRAWINGS AND SPECFICATIONS ARE. 3. REFER TO DETAIL DRAWINGS FOR ADDITIONAL INFORMATION.ALL T (503 224 9162 F (206) 340 9519 DETAILS APPLY FOR ALL APPLICABLE SITUATIONS WHETHER REFERENCED 3. FOR ELECTRICAL CONNECTIONS AND CIRCUITING TO MECHANICAL B. POWER OUTLETS,WIREMOLD, RECEPTACLES AND ALL OTHER 2. PROJECT DESCRIPTION: OR NOT, UON. EQUIPMENT SHOWN ON PLANS, REFER TO MECHANICAL AND PLUMBING ELECTRICAL DEVICES INCLUDING THEIR J-BOXES,CONDUIT AND WIRE. EQUIPMENT CONNECTION SCHEDULE. A. A MAJOR RENOVATION TO THE SCHOOL WILL OCCUR AT A FUTURE 4. CONTRACTOR IS RESPONSIBLE TO REVIEW ARCHITECTURAL DRAWINGS C. LIGHT SWITCHES INCLUDING THEIR J-BOXES, CONDUIT AND WIRE. CIVIL ENGINEER & TIME. IN PREPARATION FOR THIS MAJOR RENOVATION, THE TO CONFIRM CEILING TYPES IN ALL ROOMS(ACCESSIBLE, EXPOSED, OR 4. PROVIDE 4" HOUSEKEEPING PAD FOR ALL FLOOR MOUNTED ELECTRICAL LANDSCAPE ARCHITECT FUNCTIONS OF THE MDF ROOM IN EXISTING HUB ROOM 446A SHALL BE "HARD")AND TO USE THE APPROPRIATE WIRING METHOD FOR EACH TYPE. EQUIPMENT. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION. D. FIRE ALARM AND OTHER LOW-VOLTAGE DEVICES INCLUDING THEIR J- RELOCATED TO A NEW MDF ROOM THAT IS LOCATED TO THE SOUTH INSURE ALL J-BOXES ARE ACCESSIBLE AFTER ALL OTHER TRADE'S WORK BOXES, CONDUIT AND WIRE. Cardno EAST OF CORRIDOR 4A4R. IS COMPLETED. DO NOT LOCATE ANY J-BOXES ON "HARD"CEILINGS;ALL 5. PROVIDE SPECIAL RECEPTACLES THAT MATCH CORD AND CAP PROVIDED 6720 SW Macadam Ave, Suite 200 WIRING MUST BE ACCESSIBLE THROUGH DEVICE ONLY IN "DAISEY-CHAIN" WITH EQUIPMENT UNLESS NOTED OTHERWISE. USE ADJACENT NEMA E. FOR ALL J-BOXES ON EXPOSED CEILINGS AND WALLS, REWORK Portland, OR 97219 B. EXISTING COMPUTER LAB 448 WILL BE PARTITIONED INTO TWO METHOD OR WITH DEDICATED HOMERUNS TO EACH DEVICE. J-BOXES MAY CONFIGURATION NUMBER IF ONE IS SHOWN. CONDUIT AND WIRING IF CIRCUIT CONTAINED OR USED IN J-BOX T(503)419 2500 SPACES, ONE OF WHICH WILL BECOME THE NEW MDF ROOM. BE LOCATED ABOVE OTHER TRADE'S ACCESS DOORS IF FEASIBLE AND SERVES EXISTING TO REMAIN LIGHTING OR DEVICES, RELOCATE J-BOX STRUCTURAL ENGINEER DEMOLITION OF EXISTING SYSTEMS IN THIS SPACE WILL BE REQUIRED. DOES NOT INTERFERE WITH ACCESS. 6. REFER TO ARCHITECTURAL FLOOR PLANS, INTERIOR ELEVATIONS AND AS REQUIRED TO ABOVE ACCESSIBLE CEILING. INTENT IS TO HAVE NO Catena DETAIL DRAWINGS PRIOR TO ROUGH-IN FOR EXACT LOCATION OF BLANK COVERPLATES ON FINISHED SURFACES AT COMPLETION OF 1500 NE Irving St, Suite 412 C. THE NEW MDF ROOM SHALL BE PROVIDED WITH NEW HVAC, POWER, 5. INSTALL ALL EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS AND RECEPTACLES, FLOOR BOXES AND OUTLETS. INFORM ENGINEER OF PROJECT. Portland, OR 97232 LIGHTING,AND LOW-VOLTAGE SYSTEMS TO SUPPORT THE SCHOOL'S INSTRUCTIONS. THESE DRAWINGS ARE DIAGRAMMATIC. CONFLICTS. T(503)467 4797 MDF EQUIPMENT. F. EXISTING LUMINAIRES,ASSOCIATED CONDUIT AND CONDUCTORS. 6. PLANS INDICATE THE APPROXIMATE LOCATIONS(PLUS/MINUS A FEW FEET) 7. COORDINATE EXACT LOCATIONS OF POWERED EQUIPMENT/DEVICES(PLAN MEP ENGINEER D. WHILE DECOMISSIONING OF SOME SYSTEMS WILL OCCUR IN EXISTING OF ITEMS SHOWN UNLESS DIMENSIONS ARE CALLED OUT. AND ELEVATION LOCATIONS)AND REQUIREMENTS WITH OWNER AND G. ALL EXIT SIGNS. Glumac HUB ROOM 446A, NO ELECTRICAL DEMOLITION WORK IS TO OCCUR IN ARCHITECT PRIOR TO ROUGH-IN. EXAMPLE: 900 SW 5th Ave, Suite 1600 THIS SPACE. 7. ALL NEW RACEWAYS AND CONDUCTORS SHALL BE INSTALLED 2. WHERE REMODELING INTERFERES WITH EXISTING CIRCUITS AND Portland, OR 97204 CONCEALED; CUT AND PATCH EXISTING WALLS TO ACCOMODATE NEW A. OWNER-PROIVDED UPS EQUIPMENT WHICH IS NOT TO BE REMOVED, SUCH CIRCUITS AND T(503)227 5280 3. LIGHTING: RACEWAY INSTALLATION.ALL CONDUITS TO BE INSTALLED 90 DEGREES EQUIPMENT SHALL BE REWORKED AND RELOCATED AS REQUIRED TO AUDIO VISUAL TO BUIDLING LINES. MAINTAIN SERVICE TO ITEM. REFER ALL QUESTIONABLE SITUATIONS TO The Greenbusch Group A. REFER TO LUMINAIRE SCHEDULE FOR INFORMATION REGARDING THE ENGINEER. IF AND WHEN REWORKING CIRCUITRY, DO NOT LOCATE J- LUMINAIRE SELECTION. LUMINAIRES TO PROVIDE GENERAL 8. CIRCUIT SIZES ARE NOT SHOWN ON THE PLANS. CONTRACTOR SHALL USE BOXES ON WALLS, EXCEPT ONES REQUIRED TO MOUNT THE ITEM. I.E.AT Seat West Nickerson St, Suite 201 8119 ILLUMINATION FOR AMPLE VISIBILITY OF ROOM AND ALL EQUIPMENT. CIRCUITS SIZES INDICATED IN NOTES OR RESPECTIVE SCHEDULES PNL, THE COMPLETION OF THE PROJECT THERE SHALL BE NO J-BOXES WITH Seattle, 78 569 ( T(206)378 0569 MCC, ETC.)AND INFORMATION IN THE FEEDER AND BRANCH CIRCUIT BLANK COVERPLATES ON WALLS OR CEILINGS,THE PROJECT SHALL B. LIGHTING CONTROL FOR THE NEW MDF WILL BE PROVIDED TO ALLOW SCHEDULES. APPEAR AS NEW CONSTRUCTION. COST CONSULTANT LINE VOLTAGE SWITCHING FOR MANUAL ON/MANUAL OFF CONTROL. Construction Focus, INC. 9. BRANCH CIRCUIT WIRE SIZES 3. REMOVE ALL EXISTING BRANCH CIRCUIT CONDUCTORS AND CONDUITS 740 Almaden St 4. FIRE ALARM: ASSOCIATED WITH REMOVED ELECTRICAL EQUIPMENT AND DEVICES BACK Eugene, Or 97402 A. WHERE BRANCH CIRCUIT WIRE SIZES ARE NOT EXPLICITLY CALLED TO THE EXISTING HOMERUN FROM WHICH THEY ARE FED OR THE NEAREST T(541)686 2031 A. FIRE ALARM SHALL BE DESIGN-BUILD BASED ON PERFORMANCE OUT. BRANCH CIRCUIT WIRE SIZES FOR EACH NEW OR MODIFIED ACTIVE DEVICE THAT IS TO REMAIN. REMOVE ALL OLD TYPE WIRING IF IT IS SPECIFICATIONS. COMPLETE FIRE ALARM PLANS, DIAGRAMS,AND CIRCUIT SHALL BE BASED ON THE CIRCUIT BREAKER INDICATED ON NOT RATED FOR 90°C. CALCULATIONS SHALL BE PROVIDED BY THE FIRE ALARM THE ELECTRICAL PANEL SCHEDULES. PROVIDE THE FOLLOWING: CONTRACTOR AS PART OF A DEFERRED SUBMITTAL. 4. IF REASONABLE, EXISTING BRANCH CIRCUIT HOMERUN CONDUITS AND a. 20A-1 P C.B. 20.1 BRANCH CIRCUIT WIRES MAY REMAIN AND BE REUSED IN THE NEW CONSTRUCTION PHASE 5. ELECTRICAL DESIGN b. 20A-2P C.B. 20.2 BRANCH CIRCUIT OF WORK.THE INTENT IS TO REUSE THE MAIN INFRASTRUCTURE AND c. 20A-3P C.B. 20.3 COPPER FEEDER REMOVE ALL THE BRANCH CIRCUITING THAT WILL NO LONGER BE USED. A. DISTRIBUTION d. 30A-1 P C.B. 30.1 BRANCH CIRCUIT REMOVE EXISTING HOMERUNS BACK TO NEAREST USABLE EXISTING e. 30A-2P C.B. 30.2 BRANCH CIRCUIT JUNCTION BOX IF THEY WILL NOT BE USED AT THE COMPLETION OF THE 1. PROVIDE NEW 208/120V BRANCH PANEL AND STEP-DOWN f. 30A-3P C.B. 30.3 COPPER FEEDER PROJECT. TRANSFORMER TO FEED NEW MDF EQUIPMENT AND ASSOCIATED MEP/LV SYSTEMS. NEW BRANCH PANEL AND TRANSFORMER SHALL 10. ALL EXPOSED CONDUIT LOCATED WITHIN THE OPEN TO STRUCTURE 5. CONTRACTOR SHALL VERIFY CIRCUITS WITH TRACING DEVICE AND LABEL BE LOCATED IN EXISTING LOWER LEVEL ELECTRICAL ROOM. ENVIRONMENT SHALL BE COORDINATED WITH THE DESIGN TEAM. RUNS CIRCUITS AVAILABLE AT EACH J-BOX, MODIFY DRAWINGS AS REQUIRED TO SHOULD BE ORGANIZED AND NEATLY ROUTED THROUGHOUT THE SPACE. DOCUMENT ACTUAL CIRCUITING. 2. FEED NEW 208V/1 20V BRANCH PANEL AND STEP-DOWN ELECTRICAL SUBCONTRACTOR TO PROVIDE PROPOSED ROUTINGS FOR TRANSFORMER FROM EXISTING 480/277V PANEL SDSC IN EXISTING DESIGN TEAM APPROVAL PRIOR TO INSTALLATION. SURFACE MOUNTED 6. DO NOT REMOVE ANY CONDUITS SERVING EXISTING TO REMAIN ITEMS, O LOWER LEVEL ELECTRICAL ROOM. MC CABLE IS NOT ALLOWED ON ANY OPEN TO STRUCTURE ENVIRONMENT. ESPECIALLY TO: CONDUIT RUNS THAT NEED TO ROUTE AROUND EXISTING BEAMS TO BE O B. RECEPTACLES: COORDINATED WITH THE DESIGN TEAM PRIOR TO INSTALL. A. FAN POWERED BOXES AND OTHER MECHANICAL EQUIPMENT TO = z REMAIN. REFER TO MECHANICAL DRAWINGS FOR SCOPE OF WORK. 1. ALL RECEPTACLES SHALL COMPLY WITH NEMA, NFPA AND UL. 0 DUPLEX AND QUADPLEX RECEPTACLES SHALL BE SINGLE PHASE, B. PANELS, DISTRIBUTION PANELS,TRANSFORMERS, ETC., UON. 20 AMPS, 120 VOLT, NEMA 5-20R. C. HVAC CONTROLS AND CONTROL PANELS, UNLESS THE PIECE OF HVAC Q �n 2. PROVIDE MDF ROOM WITH: EQUIPMENT IS TO BE REMOVED. REFER TO MECHANICAL DRAWINGS _ U AND SPECS. FOR SCOPE OF WORK. 7- LL_a. ONE L6-30R FOR AN OWNER-SUPPLIED UPS. D. CONDUITS AND J-BOXES TO FIRE ALARM DEVICES ON EXISTING TO z 0 b. FOUR WALL-MOUNTED QUADPLEX RECEPTACLES WITH REMAIN WALLS. O DEDICATED CIRCUITS. LOCATE QUADPLEX RECEPTACLES SUCH THAT TWO ARE NEXT TO EACH ROW OF EQUIPMENT E. BRANCH CIRCUIT WORK SERVING EXISTING LIGHTING TO REMAIN. Q RACKS. -I F. DOOR HOLDERS, ROLL-DOWN FIRE DOORS, ROLL-UP DOORS AND Q c. FOUR WALL-MOUNTED DUPLEX RECEPTACLES. LOCATE ONE THEIR ASSOCIATED POWER AND CONTROL WIRING, UON. DUPLEX RECEPTACLE ON EACH WALL. G. EXTERIOR LIGHTING AND ASSOCIATED LIGHTING CONTROL WIRING. C. NORMAUSTANDBY POWER H. CONTROL, POWER WIRING AND TELECOM WIRING ASSOCIATED WITH a. TIGARD-TUALATIN SCHOOL DISTRICT STANDARDS REQUIRE ALL ELEVATORS. STANDBY POWER BE PROVIDED TO MDF/IDF ROOMS. THE AFOREMENTIONED FUTURE MAJOR RENOVATION SHALL MODIFY I. SECURITY DEVICES, EQUIPMENT, CONDUIT AND WIRING, UNLESS THE ELECTRICAL INFRASTRUCTURE SUCH THAT THE NEW 208/120V OTHERWISE NOTED. BRANCH PANEL AND STEP-DOWN TRANSFORMER FEEDING THE NEW MDF ROOM WILL BE RE-FED FROM A FUTURE GENERATOR, 7. ALL REMOVED ELECTRICAL MATERIAL, INCLUDING WIRING, RACEWAYS, PROVIDING THE REQUIRED STANDBY POWER. UNTIL THIS TIME, OUTLETS, DEVICES,AND SUPPORTS SHALL BECOME THE PROPERTY OF ONLY NORMAL POWER SHALL BE PROVIDED TO THE MDF ROOM. THE CONTRACTOR AND SHALL BE REMOVED FROM THE JOB SITE. 6. MECHANICAL/PLUMBING EQUIPMENT POWER CONNECTIONS 8. CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO SUBMISSION OF BID AND FIELD VERIFY ALL EXISTING CONDITIONS AND THE EXTENT OF THE A. PROVIDE POWER TO NEW MECHANICAL AND PLUMBING EQUIPMENT/ DEMOLITION WORK.ALL ASSOCIATED DEMOLITION COSTS SHALL BE DEVICES. INCLUDED IN THE BID PRICE. NO EXTRA PAYMENT WILL BE ALLOWED FOR WORK REQUIRED BECAUSE OF DISCERNIBLE CONDITIONS,WHETHER OR B. CIRCUIT AND POWER WIRING BY DIVISION 26 NOT SPECIFICALLY SHOWN ON THESE DRAWINGS. C. DISCONNECT SWITCHES ARE BY DIVSION 26 Z4� REVISIONS DATE D. VARIABLE FREQUENCY DRIVES(VFDS)AND STARTERS ARE BY DIVISION 23 7. MECHANICAL CONTROLS ARE BY DIVISION 23 TIGARD TUALATIN SCHOOL DISTRICT TIUARD HIGH SCHOOL \AODERNIZATION 9000 SW DURHAM RD. TIGARD, OR. 97224 JOB N0: 16992.00 ISSUE DATE: 04/18/2018 Jurisdiction Stamp Area EXPIRES: 12/31/19 PRO GI G ce 757 7PE a�OREGON IFN BASIS OF DESIGN AND o 0 NOTES u700 � M C O 0y co w MDF . EO1 i MECHANICAL AND PLUMBING EQUIPMENT - ELECTRICAL CONNECTION SCHEDULE - MDF TAG LOAD CIRCUITING INFORMATION DISCONNECT STARTER LOCATION NAME # DESCRIPTION HP IGI KVA FLA LOAD CLASS VOLTS 0 PANEL CIRCUIT OCP POLES FEEDER DIV. TYPE DIV TYPE LEVEL ROOM# NOTES bassetti CU 15 CONDENSING UNIT 0 hp 4.49 kVA 21.6 A C 208 V 1 SLSO 15,17 30 A 2 30.2 DIV. 26 FUSED DIV. 23 INTEGRAL UPPER LEVEL architects CU 16 CONDENSING UNIT 0 hp 4.49 kVA 21.6 A C 208 V 1 SLSO 19,21 30 A 2 30.2 DIV.26 FUSED DIV. 23 INTEGRAL UPPER LEVEL CU 17 CONDENSING UNIT 0 hp 4.49 kVA 21.6 A C 208 V 1 SLSO 23,25 30 A 2 30.2 DIV.26 FUSED DIV. 23 INTEGRAL UPPER LEVEL FCU 15 FAN COIL UNIT 0 hp 0.47 kVA 2.3 A C 208 V 1 SLSO 11,13 15A 2 20.2 DIV, 26 FUSED DIV. 23 INTEGRAL MAIN FLOOR Po NW 9th Ave, Suite 350 FCU 16 FAN COIL UNIT 0 hp 0.47 kVA 2.3 A C 208 V 1 SLSO 11,13 15 A 2 20.2 DIV.26 FUSED DIV. 23 INTEGRAL MAIN FLOOR Portland, Oregon 97209 FCU 17 FAN COIL UNIT 0 h 0.47 kVA 2.3 A C 208 V 1 SLSO 11,13 15 A 2 20.2 DIV. 26 FUSED DIV. 23 INTEGRAL MAIN FLOOR T (503 224 9162 F (206) 340 9519 SCHEDULE NOTES A. ALL LISTED ITEMS ARE PROVIDED BY DIVISION 22 AND/OR DIVISION 23. PROVIDE POWER TO ITEMS AS INDICATED ON PLANS AND IN THE SCHEDULE. B. COORDINATE WITH DIVISIONS 22 AND 23 PRIOR TO INSTALLATION AND VERIFY OVERCURRENT PROTECTION AND FEEDER REQUIREMENTS WITH SUBMITTED MANUFACTURER DATA. INFORM ENGINEER OF CONFLICT(S). CIVIL ENGINEER & C. WHERE HP IS SHOWN AS"0", REFER TO FLA AND KVA FOR ELECTRICAL LOAD. LANDSCAPE ARCHITECT Cardno 6720 SW Macadam Ave, Suite 200 Portland, OR 97219 T(503)419 2500 STRUCTURAL ENGINEER Catena 1500 NE Irving St, Suite 412 Portland, OR 97232 T(503)467 4797 MEP ENGINEER Glumac 900 SW 5th Ave, Suite 1600 Portland, OR 97204 T(503)227 5280 _ AUDIO VISUAL LUMINAIRE SCHEDULE - MDF The Greenbusch Group 1900 West ickerson St, Suite 201 COLOR POWER Seattle,WA 98119 WTWT DESCRIPTION LAMP TEMP MANUFACTURER MODEL SUPPLY VOLTAGE LOAD MOUNTING COMMENTS T(206)378 0569 FA1 1.5 INCH WIDTH BY 48 INCH LENGTH SURFACE MOUNTED LED 32W LED 3500K LITHONIA ZL2N INTEGRAL 120 V 32 W SURFACE PROVIDE WALL CHAIN OR COST CONSULTANT STRIPLIGHT A MEDIUM DIFFUSE LENS. 2000 ELECTRONIC SURFACE MOUNT AS REQUIRED LUMENS DRIVER Construction Focus, INC. ---- -- 740 Almaden St LUMINAIRE SCHEDULE NOTES: Eugene, Or 97402 T(541)686 2031 A. FURNISH ALL LIGHTING FIXTURES COMPLETE WITH MOUNTING ACCESSORIES TO MEET JOB REQUIREMENTS.VERIFY FIXTURE MOUNTING AND LOCATION AGAINST ARCHTECTS PLANS, ELEVATIOINS AND DETAIL DRAWINGS. EXACT LOCATIONS OF ALL FIXTURES SHALL BE CONFIRMED WITH THE ARCHITECT PRIOR TO ROUGHING IN. B. SERIES FIXTURES SHALL SATISFY LENGTHS AS SHOWN ON DRAWINGS. FIXTURE LETTERS SHOW ONCE ON A CONTINUOUS ROW OF FIXTURES SHALL BE TYPICAL FOR THAT ROW UNLESS OTHERWISE NOTED. C. ALL FIXTURES SHALL BE SUPPORTED FROM THE BUILDING STRUCTURE, INDEPENDENT OF HUNG CEILING WITH ROD OR JACK CHAIN SUPPORT. STEM LENGTHS, STEM FINISHES AND STEM LOCATIONS OF ALL PENDANT FIXTURES TO BE VERIFIED AND CONFIRMED BY OWNER,ARCHTECT AND ENGINEER PRIOR TO ORDERING STEMS. D. ALL DIMMABLE DRIVERS SHALL BE COMPATABLIE WITH LAMPS AND DIMMERS. E. ALL LIGHT FIXTURES ARE TO BE PROVIDED BY SPECIFIED MANUFACTURER OR APPROVED EQUAL. "ALTERNATE MANUFACTURER"AND"OR APPROVED EQUAL" MEAN EQUIVALENT OR SUPERIOR IN PERFORMANCE, MATERIALS, WORKMANSHIP AND APPEARANCE TO THE SPECIFIED EQUIPMENT. F. CONTRACTOR SHALL PROVIDE AND INSTALL ALL TRANSFORMERS AND/OR DRIVERS REQUIRED TO OPERATE ALL LAMPS SPECIFIED, INCLUDING REMOTE DRIVERS AND/OR TRANSFORMERS AND THE ENCLOSURES FOR SAME. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF COMPATIBILITY BETWEEN LAMPS SPECIFIED, DRIVERS AND/OR TRANSFORMERS SPECIFIED,AND DIMMING AND OTHER CONTROL DEVICES SPECIFIED. NOTIFY ARCHITECT AND ENGINEER CONSULTANT OF ANY INCOMPATIBILITY PRIOR TO ORDERING EQUIPMENT. G. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE COORDINATION OF ALL LIGHITNG EQUIPMENT AND CONTROL DEVICES WITH CEILING AND WALL TYPES SPECIFIED PRIOR TO ORDERING LIGHTING EQUIPMENT. H. ALL FIXTURES SHALL USE LAMPS OF COLOR TEMPERATURE OF 3500K WHEN AVAILABLE UNLESS OTHERWISE NOTED. I. PRELIMINARY AIMING OF ALL ADJUSTABLE LIGHTING EQUIPMENT SHALL BE DONE DURING INSTALLATION BY THE ELECTRICAL CONTRACTOR AS INDICATED ON THE LIGHTING PLANS/AIMING DIAGRAM,WHERE SUCH A DIAGRAM IS INCLUDED IN THE CONTRACT DOCUMENTS OR AS AN ADDENDUM. FINAL AIMING OF ALL ADJUSTABLE LIGHTING EQUIPMENT SHALL BE DONE BY THE ELECTRICAL CONTRACTOR AS DIRECTED BY THE ARCHITECT. J. INA LL FIXTURES WITH ADJUSTABLE SOCKETS, SET SOCKETS DURING INSTALLATION TO LOCATED SPECIFIED LAMP IN CORRECT RELATIONSHIP TO REFLECTOR AS RECOMMENDED BY FIXTURE MANUFACTURER. 0 LIGHT FIXTURES COUNTS INDICATED ARE FOR COORDINATION AND CALCULATION PURPOSES ONLY AND SHOULD NOT BE USED FOR PRICING OR PURCHASING. CONTRACTOR IS RESPONSBILE FOR PROVIDING ADEQUATE QUANTITIES OF 0 FIXTURES AND ACCESSORIES TO HAVE A COMPLETE INSTALLATION OF ALL LIGHTING SYSTEMS. = z CU O cn C� Q _ U _ LL Z p F- O Q � Q REVISIONS DATE TIGARD TUALATIN SCHOOL TIUARD HIGH SCHOOL VIODERNIZATIO4' 9000 SW DURHAM RD. TIGARD, OR. 97224 JOB NO: 16992.00 ISSUE DATE: 04/18/2018 Jurisdiction Stamp Area EXPIRES: 12/31/19 t.D PROFFsf 1��G 1 Nre 757 7PE OREGON o �o ,21 J~ /FN T. Bl.\P�O MECH & PLUMB (0 0 EQUIP CONN & LUMINAIRE 66 00 SCHEDULES C)00N W MDF . E03 0- Y ` bassetti architects 721 NW 9TH Ave, Suite 350 Portland, Oregon 97209 T (206) 340 9500 F (206) 340 9519 CIVIL ENGINEER & LANDSCAPE Cardno 6720 SW Macadam Ave Suite 200, Portland, OR 97219 T(503)-419-2500 STRUCTURAL ENGINEER Catena Engineers 1500 NE Irving St., Suite 412 Portland, OR 97232 T(503)-467-4980 MECHANICAL ELECTRICAL & PLUMBING ENGINEER Glumac 900 SW Fifth Ave., Suite 1600 Portland, OR 97204 T(503)-227-5280 FOOD SERVICE CONSULTANT Webb Foodservice Design 3700 SE Lafayette Ct. Portland, OR 97202 T(503)-236-8566 ACOUSTIC &AV CONSULTANT The Greenbusch Group 1900 W. Nickerson St., Suite 201 Seattle,WA 98119 T 206-378-0569 COST CONSULTANT Construction Focus 740 Almaden St. Eugene, OR 97402 T 541-686-2031 CA - - - - - - C1 - C3 - - -C4 C6 C7 CB - - - - - I I o GII III I I I 0 0 0 Fu yly IV PER THE BASIS OF DESIGN,WHILE DECOMISSIONING OF SOME SYSTEMS WILL OCCUR IN EXISTING HUB ROOM 446A, NO u ELECTRICAL DEMOLITION WORK IS TO OCCUR IN THIS SPACE._ _ - __ --------- CF -_-_-CFFYI - E ---- SB �= N I I I I I I I — — — — — — M SC - I I I I EXISTING MDF ROOM - DEMOLITION I L SCALE: 1/2"= 1'-0° Scale - �- - I- - - �- - - - - K S E - - - -- - -- 0 2--0" 4'-0" 6'-0„ V-011 S F --- -- -fi — �- --�-- — — — coRR — — — H 4� DATE 4A4R I I i I I 2 1�9L!m� o - 1111 171ILtItILL - SG I I I I I OMPUT LAB = — — I , F 448 s SH — — — — — _ — I I I I I I I E L — — — — — D 1 I I I I I I I EXISTING WALL. REMOVE ALL ELECTRICAL 1 DEVICES ON THE INTERIOR SIDE OF THIS 1 SPACE UNLESS NOTED OTHERWISE. SM I 71 I I I I _ — — — — — — g 1 1 TIGARD TUALATIN SCHOOL DISTRICT SN [ 3 _ II 1 TIGARD HIGH I 1 SCHOOL i MODERNIZATION I ( I REMOVE EXISTING LIGHTING 1 WITHIN THIS SPACE. 1 9000 SW DURHAM RD. — — — � — — — — — �_ — • TIGARD, OR.97224 SQ i I I I 1 JOB NO: 16992.00 14 13 11 9 7 5 3 1 1 ISSUE DATE: 04/18/2018 1 Jurisdiction Stamp Area 1 EXPIRES: 12/31/19 I I I I PRO IFFSs� N 1 757 7PE 1 I I i 1 aF�OREGONo 1 FN T B0P�o i (S)l S3 S4 S5 CS 6 S7S9 S1OS111 ISlZS14) ELECTRICAL PLANS LL o - DEMOLITION MAIN FLOOR - OVERALL FLOOR PLAN - ELECTRICAL - DEMOLITION NEW MDF ROOM - DEMOLITION 1 SCALE: 1/32"= 1-0 SCALE: 1/2"= 1-0 Scale Scale f"y MDF . E1 1 - 1 0 2'-0" 4'-0" 6'-0" 8'-0" W 0 32'-0" 64'-0" 96'-0" 128'-0" 0— bassetti architects 721 NW 9th Ave, Suite 350 Portland, Oregon 97209 T (503 224 9162 F (206) 340 9519 CIVIL ENGINEER & LANDSCAPE ARCHITECT Cardno 6720 SW Macadam Ave, Suite 200 Portland, OR 97219 T(503)419 2500 STRUCTURAL ENGINEER Catena 1500 NE Irving St, Suite 412 Portland, OR 97232 T(503)467 4797 MEP ENGINEER Glumac 900 SW 5th Ave, Suite 1600 Portland, OR 97204 T(503)227 5280 AUDIO VISUAL The Greenbusch Group 1900 West Nickerson St, Suite 201 Seattle,WA 98119 T(206)378 0569 COST CONSULTANT Construction Focus, INC. 740 Almaden St Eugene, Or 97402 T(541)686 2031 %i 0 0 r Cn 0 � v _ LL _Z p �— 0 Q J - ' Q -- I SB I T' Sc SE - - - L- SF 0 REVISIONS DATE SIG I I I SH h � FD IJ IIIIIIIII II I I — SM - - -- r � uC 4 2 °°°°°❑ on K 88 DF.E ❑°°O°° ° TI ARD T ALATIN SCHOOL E-D E3 0 MECH. DDC G U SC 00 I DISTRICT h I - _ = CONTROL PANEL TIUARD J - FIRE/SMOKE DAMER XFR-SLSO RELAYS FOR RTU-1, HIGH RTU-2,AND RTU-3 PNL-SLSO ' EK SCHOOL a a a A d PNL-X ; MODERNIZATION 9000 SW DURHAM RD. TIGARD, OR. 97224 I I I I JOB NO: 16992.00 ISSUE DATE: 04/18/2018 PNL-4X - - - - - - "�" � Jurisdiction Stamp Area EXPIRES: 12/31/19 ® 0 PNL-SCA 5�`���DPNOFFsf� \ N Ce 9 757 7PE a OREGON I I I I I IR XFR-T-SCA /FN r BO PCO S1 S3 S4 S5 S6 S7 S9 �S11) � - ELECTRICAL PNL-SDSC _______ � o PLANS LOWER CID CD LOWER LEVEL - OVERALL FLOOR PLAN - ELECTRICAL LOWER LEVEL ELECTRICAL ROOM - ELECTRICAL LEVEL 00 SCALE: 1132 - 1 0 SCALE: 1/4 - V-0" Scale C C) Scale G 00 N r�/ 0 4'-0" 8'-0" 12'-0" 16'-0" W IMDFE20 0 32'-0" 64'-0" 96'-0" 128'-0" SHEET NOTES KEYED NOTES ® A. CIRCUIT NUMBERS SHOWN ON THIS SHEET WITHOUT A 1 PROVIDE L6-30R FOR OWNER-PROVIDED TRIPP LITE bassetti PANEL PREFIX CORRESPOND TO PANEL SLSO UNLESS SMART5000RT3U UPS, COORDINATE WITH OWNER FOR NOTED OTHERWISE. FINAL LOCATION,AND INSTALL OUTLET AT DETERMINED architects LOCATION. 721 NW 9th Ave, Suite 350 Portland, Oregon 97209 T (503 224 9162 F (206) 340 9519 CIVIL ENGINEER & LANDSCAPE ARCHITECT Cardno 6720 SW Macadam Ave, Suite 200 Portland, OR 97219 T(503)419 2500 STRUCTURAL ENGINEER Catena 1500 NE Irving St, Suite 412 Portland, OR 97232 T(503)467 4797 MEP ENGINEER Glumac 900 SW 5th Ave, Suite 1600 Portland, OR 97204 T(503)227 5280 AUDIO VISUAL The Greenbusch Group 1900 West Nickerson St, Suite 201 Seattle,WA 98119 T(206)378 0569 COST CONSULTANT Construction Focus, INC. 740 Almaden St Eugene, Or 97402 T(541)686 2031 CA — C1 C3 C4 C6 C7, CB H — – – II 0 "Tz 0 00000 AIL>I I I t o l I I I ITDT 0 = Q 0 U I I I II 4ICA' D Igl �= 0 I I ► I I I I I J IFF-OFF-M ell I I I ppm L � I I SA — 0 1 1 1 — — — — Q z_ P I _ _ I I I N I_ � 1-11 AI I I © — — — — • — M SC + I I I I I I I I — — — — — — L SE — — — "K SF H II >. � I I �' I I I I I REVISIONS DATE i — G SG — ILI _ __j � — — I — I — = _ - - - - F SHE — — E Li Li Li U I I — — — — — SCA-7 FCU I D 16 FA1 SCA-7 I I I I I , I I I — — — — — _ B 5 SM — — FT Y1 A- - ^ SCA-13 TIGARD TUALATIN SCHOOL — — — - — `� — DISTRICT SN I I I I I I TIt�HRD J HIGHL I I I I I a I h I 3 F17U SCHOOL FA1 I I I I I I I I 5 \AODERNIZATION IF min1 UPS 1 9000 SW DURHAM RD. L6-30R U) TIGARD, OR. 97224 79 1 I I I I I JOB NO: 16992.00 I 14 13 11 9 7 5 3 1 ISSUE DATE: 04/18/2018 Jurisdiction Stamp Area I EXPIRES: 12/31/19 I I I I I E3 I I I I SCA- 11 FCU D PROFFs 15 ��\G I NE FA1 7570,7 E SCA-7 o OREGON I I MDF 5 E116 /FN T BL�P�O SCA-7 S1 S3 S4 S5 S6 S7 S9 (S10pS111 (SlZS141 _ - ELECTRICAL o PLANS - MAIN MAIN LEVEL - OVERALL FLOOR PLAN - ELECTRICAL MAIN LEVEL - MDF ROOM - ELECTRICAL LEVEL SCALE: 1/32"= 1'-0" SCALE: 112" = V-0" Scale o Scale 75 00 N W MDF . E21 0 32"-0" 64'-0" 96'-0" 128'-0" 0 2'-0" 4'-0" 6'-0" 8'-0" SHEET NOTES A. CIRCUIT NUMBERS SHOWN ON THIS SHEET WITHOUT A PANEL PREFIX CORRESPOND TO PANEL SLSO UNLESS b8ssetti NOTED OTHERWISE. 8/"C17lteCtS 721 NW 9th Ave, Suite 350 Portland, Oregon 97209 T (503 224 9162 F (206) 340 9519 CIVIL ENGINEER & LANDSCAPE ARCHITECT Cardno 6720 SW Macadam Ave, Suite 200 Portland, OR 97219 T(503)419 2500 STRUCTURAL ENGINEER Catena 1500 NE Irving St, Suite 412 Portland, OR 97232 T(503)467 4797 MEP ENGINEER Glumac 900 SW 5th Ave, Suite 1600 Portland, OR 97204 T(503)227 5280 AUDIO VISUAL The Greenbusch Group 1900 West Nickerson St, Suite 201 Seattle,WA 98119 T(206)378 0569 COST CONSULTANT Construction Focus, INC. 740 Almaden St Eugene, Or 97402 T(541)686 2031 CA - - - - - -? -- - - - - - - CB 00 I I I U) �I LD U LL _Z p 73 oil — — — I I I I I I I J I I Q SB - - - - M SC I I I I I I SE - - - - K - -- - - - C� SF Al H 0 I I I I I I I # REVISIONS DATE -- - - G 14 SG - - - - - - F SHP�- FL__T - I - - I I I E p - -- - _ - - F I I I I I I I I SMEl El ! TIGARD TUALATIN SCHOOL j I n T1 (DjARISTRICTD I I II I I I I � I HIGH SCHOOL MODERNIZATION 5w 1I I I 9000 SW DURHAM RD. TIGARD, OR. 97224 i I JOB NO: 16992.00 1413 11 9 7 5 3 1 ISSUE DATE: 04/18/2018 Jurisdiction Stamp Area EXPIRES: 12/31/19 I I I I I I I I t.D PROFFsf� CU CU CU SCA- 15 757 7PE Dy 17 15 16 WP I I I I I I ! N FN T. B0P�O �S1 S3 S4 S5 CS D6 S7 S9 (S101S11) (S13) - E ELECTRICAL UPPER LEVEL 1 ROOF o PLANS - UPPER UPPER LEVEL / ROOF - OVERALL FLOOR PLAN - ELECTRICAL MDF CONDENSING UNITS LEVEL / ROOF SCALE: 1/32" = 1 1' '-0" SCALE: 1/2"= -0" 0 Scale Scale 0 %%AAM6?%w!n i M^ w MDF . E22 0 32'-0" 64'-0" 96'-0" 128'-0" 0 2'-0" 4'-0" 6'-0" 8'-0" PANEL: SCA (EXISTING PANEL) PANEL: SLSO VOLTAGE: 208Y/120V, 3PH, 4W VOLTAGE: 208Y/120V, 3PH,4W NEMA RATING: Type 1 SHEET NOTES KEYED NOTES (:#:) I MOUNTING: SURFACE INTEGRAL SPD: No BUS RATING: 400 A BUS RATING: 225 A ISOL GROUND BAR: No A. REFER TO SHEET E0.00 FOR LEGEND. 1 PROVIDE METERING FOR 30 DAYS TO DETERMINE THE DEMAND LOAD OF THE PANEL DIRECTLY DOWNSTREAM bassetti MAIN AMPS: 400 A MCB LOCATION: MAIN AMPS: 225 A MCB FEED-THRU LUGS: No LOCATION: AIC RATING: SEE 1-LINE DOUBLE-LUGS: No SUPPLY FROM: XFR-SLSO B. REFER TO SHEET E0.02 FOR FEEDER SIZES. OF THIS POINT PER NEC 220.87. THE INTENT IS TO architects CONFIRM THAT THE PANEL HAS THE CAPACITY TO CKT TRIP POLE DESCRIPTION TYPE A(kVA) B(kVA) C(kVA) TYPE DESCRIPTION POLE TRIP CKT CKT TRIP POLE DESCRIPTION TYPE A(kVA) B(kVA) C(kVA) TYPE DESCRIPTION POLE TRIP CKT C. ALL CIRCUITS ARE 3-PHASE UNLESS NOTED OTHERWISE. SUPPORT THE ADDED DOWNSTREAM LOAD(S). SUBMIT METERED RESULTS TO ENGINEER FOR REVIEW PRIOR 1 20 A 1 {EC}RECEP. ELECTRICAL RM R 0.18 4 K {EC}RANGE PLUG SCIENCE STORAGE 2 50 A 2 1 20 A 1 MDF E116-RECEPT R 0.36 0 -- SPARE 1 20 A 2 D. ALL TRANSFORMERS ARE 480V DELTA PRIMARY TO TO THE PURCHASE OF MATERIALS AND CONSTRUCTION. 3 20 A 1 EC}MECH. CONTROL PANEL C 0.2 4 -- -- - -- 4 3 20 A 1 MDF El 16-RECEPT R 0.36 0 -- SPARE 1 20 A 4 208Y/120V SECONDARY UNLESS NOTED OTHERWISE. 721 NW 9th Ave, Suite 350 5 20 A 1 {EC}OUTSIDE KILN N 0.2 0 - SPACE -- -- 6 5 20 A 1 MDF El 16-LIGHTING L 1 0.1 0 ISPARE 1 20 A 6 Portland, Oregon 97209 7 120 A 1 1 {NL}MDF-RECEPTS R 1.44 1 0.9 1 1 R I{EC)RECEPTS 255 256 1 20A 1 8 7 130A 1 2 L6-30R-5KVA UPS R 1 2.5 0 ISPARE 1 120A 8 E. THE VALUE SHOWN IN A WIDE HEXAGON BY A PIECE OF T (503 224 9162 F (206) 340 9519 9 20 A 1 {EC}246-OFFICE R 0.72 0 -- ISPACE - -- 10 9 -- -- -- -- 2.5 0 - SPARE 1 20 A 10 EQUIPMENT IS THE AVAILABLE INTERRUPTING 11 20 20 A 1 {NL}MDF El 16-RECEPT R 0.36 0 -- SPACE -- -- 12 11 20 A 2 MDF E116 FCU's FCU-15, 16, 17) C 0.71 0 - SPARE 1 20 A 12 CIRCUIT CURRENT(KAIC)AT THAT PIECE OF EQUIPMENT. 13 20 A 1 {NL}MDF El 16-RECEPT R 0.36 4 N {EC}PANEL SCF 3 100 A 14 13 - - -- -- 0.71 0 - SPARE 1 20A 14 15 20 A 1 {NL}UPPER LEVEL/ROOF-RECEPT R 0.18 4 - -- -- -- 16 15 30A 2 CU-15(ON UPPER LEVEL/ROOF) C 2.25 0 - SPARE 1 20 A 16 F. NEW AVAILABLE FAULT CURRENT VALUES WERE CIVIL ENGINEER & 17 20A 1 SPARE - 0 4 - -- -- -- 18 17 -- - -- -- 2.25 0 - SPARE 1 20 A 18 CALCULATED USING STANDARD TRANSFORMER LANDSCAPE ARCHITECT 19 20 A 1 SPARE -- 0 4 N {EC}PANEL BR 3 100 A 20 19 30 A 2 CU-16(ON UPPER LEVEL/ROOF) C 2.25 0 - SPARE 1 20 A 20 IMPEDANCE VALUES FROM SKM POWER TOOLS Cardno SOFTWARE.THESE VALUES ARE SHOWN TO ASSIST IN 6720 SW Macadam Ave, Suite 200 21 20 A 1 SPARE -- 0 4 - - -- -- 22 21 -- -- -- -- 2.25 0 - SPARE 1 20 A 22 PRICING ONLY. CONTRACTOR IS REQUIRED TO PROVIDE A Portland, OR 97219 23 20 A 1 SPARE -- 0 4 -- -- -- -- 24 23 30 A 2 CU-17(ON UPPER LEVEL/ROOF) C 2.25 0 - SPARE 1 20 A 24 FAULT CURRENT STUDY PER SPECIFICATION 260573, T(503)419 2500 25 20 A 1 {EC}REC. SCIENCE STOR&BUILDIN... R 0.72 0.8 K {EC}FREEZER-SCIENCE STORAGE 1 20 A 26 25 -- -- -- -- 1 2.25 0 - SPARE 1 20 A 26 SECTION 3.3.ALL NEW EQUIPMENT SHALL BE RATED FOR STRUCTURAL ENGINEER 27 20 A 1 {EC}RECEPTS SCIENCE STORAGE R 0.72 0.8 K {EC}REFRIGERATORS-SCIENCE... 1 20A 28 27 20 A 2 ROOFTOP CU-2 {F} C 1.5 0 - SPARE 1 20 A 28 THEIR RESPECTIVE CALCULATED AVAILABLE FAULT Catena 29 20 A 1 (EC)RECEPTS SCIENCE STORAGE R 0.72 0.8 K {EC}DISHWASHER-SCIENCE STORAGE 1 20 A 30 29 -- -- -- -- 1.5 0 -- SPARE 1 20 A 30 CURRENT. 31 20 A 1 EC RECEPTS SCIENCE STORAGE R 0.72 0.8 K EC PLUG&RANGE HOOD-SCIENCE... 1 20 A 32 31 20 A 2 ROOFTOP CU-3 {F} C 1.5 0 -- SPARE 1 20 A 32 1500 NE Irving 2 Suite 412 { } { } Portland, OR 97232 33 -- -- SPACE -- 0 1.2 K {EC}DISPOSAL SCIENCE STORAGE 1 120 A 1 34 33 - - -- -- 1 1.5 0 -- SPARE 1 20 A 34 T(503)467 4797 35 -- -- SPACE -- 0 0.2 N {EC}LTG. CONTROL FOR XD-6,8 1 20 A 36 35 20 A 2 ROOFTOP CU-4 {F} C 1.5 0 -- SPARE 1 20 A 36 37 150 A 3 {EC}PANELS SCD&SCE N 10 10 N {EC}PANELS SCB&SCC 3 150 A 38 37 -- - -- - 1.5 0 - SPARE 1 20A 38 MEP ENGINEER 39 -- - -- -- 10 10 -- -- -- 40 39 20 A 2 ROOFTOP CU-11 {F} C 1.5 0 - SPARE 1 20 A 40 900 SW 5 th Ave, Suite 1600 41 -- -- -- -- 10 10 -- -- - 42 41 -- -- - -- 1.5 0 -- SPARE 1 20 A 42 900 SW 5 Portland, OR 97204 SPECIAL PANEL FEATURES 37.92 kVA 35.82 kVA 30.28 kVA CIRCUIT NOTES SPECIAL PANEL FEATURES 10.62 kVA 11.41 kVA 9.77 kVA CIRCUIT NOTES T(503)227 5280 323.1 A 305.6 A 252.3 A {EC}= EXISTING CIRCUIT TO REMAIN 89.6 A 96.2 A 81.4 A {F}= FUTURE LOAD {NL}= NEW LOAD ON EXISTING BREAKER AUDIO VISUAL The Greenbusch Group 1900 West Nickerson St, Suite 201 LOAD TYPE CONNECTED DEMAND FACTOR DEMANDIADJUST... LOAD TYPE KEY PANEL TOTALS LOAD TYPE CONNECTED DEMAND FACTOR DEMAND/ADJUST... LOAD TYPE KEY PANEL TOTALS Seattle,WA 98119 C 0.2 kVA 125% 0.25 kVA C=CONTINUOUS KVA AMPS C 22.39 kVA 125% 27.99 kVA C=CONTINUOUS KVA AMPS T(206)378 0569 K 12.4 kVA 65% 8.06 kVA E= ELEVATOR TOTAL CONNECTED LOAD: 104.02 kVA 288.7 A L 0.1 kVA 125% 0.12 kVA E=ELEVATOR TOTAL CONNECTED LOAD: 31.73 kVA 88.1 A COST CONSULTANT N 84.4 kVA 100% 84.4 kVA K=KITCHEN TOTAL DEMAND LOAD: 99.73 kVA 276.8 A R 5.72 kVA 100% 5.72 kVA K= KITCHEN TOTAL DEMAND LOAD: 38.43 kVA 106.7 A Construction Focus, INC. R 7.02 kVA 100% 7.02 kVA L=LIGHTING SPARE CAPACITY: 0% 0% Motor 4.49 kVA 125% 5.61 kVA L=LIGHTING SPARE CAPACITY: 25% 25% 740 Almaden St M=MOTOR REQUIRED CAPACITY: 99.73 kVA 277 A M=MOTOR REQUIRED CAPACITY: 48.04 kVA 133 A Eugene, Or T(541)686 2031 2031 MOTOR=LARGEST MOTOR MOTOR=LARGEST MOTOR N=NON-CONTINUOUS N= NON-CONTINUOUS R=RECEPTACLE R= RECEPTACLE PANEL SCHEDULE NOTES A. EXISTING LOAD VALUES ARE UNKNOWN. PROVIDE 30-DAY METERING PER PARTIAL SINGLE-LINE DIAGRAM TO VERIFY THIS PANEL HAS THE CAPACITY TO ADD THE SHOWN NEW LOADS PRIOR TO THE PURCHASE OF MATERIALS AND CONSTRUCTION. 0 0 = z CU O U) CD Q U Z p �-- 0 Q :5 J Q TO UPSTREAM PNL PNL - - - - - -- - SUB- SCA SLSO -- --- -- DISTRIBUTION PANEL SDH _ 10 KAIC Z� REVISIONS DATE 6.3 5.2 1 XFR XFR T-SCA SLSO 208Y/120V 208Y/120V 1 TO EXISTING TO EXISTING 150 KVA 75 KVA EQUIPMENT/ EQUIPMENT/ DEVICES DEVICES (� R TIGARD TUALATIN SCHOOL (E) (E) (E) XFR TIUDISARTRICTD PANEL SDSC <ED HIGH 600A,480/277V,3P SCHOOL PARTIAL SINGLE-LINE DIAGRAM \AODERNIZATION 9000 SW DURHAM RD. TIGARD, OR. 97224 JOB NO: 16992.00 ISSUE DATE: 04/18/2018 Jurisdiction Stamp Area EXPIRES: 12/31/19 i, PRO s(", G I N f'6- la, 757 7PE o�OREGON SINGLE-LINE D IAG RAM AND co 0 u7 PANEL 00 75 SCHEDULES 00 w MIDIFE51 DETAIL GENERAL NOTES SHEET NOTES A APPLY BACKBOARD AS SHOWN TO ALL WALLS WITHIN A EXISTING MDF ROOM TO BE RELOCATED TO NEW COMMUNICATIONS EQUIPMENT ROOMS UNLESS NOTED ' OTHERWISE. LOCATION. CABLING CURRENTLY TERMINATED IN THE 117seMDF ROOM THAT SUPPORTS NETWORK CONNECTIVITY TO AREAS EITHER OUTSIDE OF THE SCOPE OF WORK, itects OR AREAS THAT NEED TO REMAIN CONNECTED KEYED NOTES DURING DEMO AND PHASE 1 WORK,TO BE RE-ROUTED 1 8'H x 4'W,3/4"VOID FREE PLYWOOD BACKBOARD AND RE-TERMINATED WITHIN THE NEW MDF LOCATION g � 0 TREATED WITH NON-CONDUCTIVE, FIRE- PRIOR TO DEMO AND PHASE 1 WORK.ASSUME(12) 12- STRAND FIBER OPTIC CABLES,AND(150)CATEGORY 6 721 NW 9TH Ave, Suite 350 12 w. RETARDANT PAINT. CABLES. Portland, Oregon 97209 - �® �9 2 VISIBLE LABEL/STAMP ON BACKBOARD INDICATING T (206) 340 9500 F (206) 340 9519 B RACK ELEVATIONS ARE SHOWN FOR REFERENCE. THE FIRE-RATING. ACTUAL RACK ELEVATIONS WILL NEED FINAL 1 1 COORDINATION AND VERIFICATION WITH DISTRICT'S IT ® A n ® REPEAT AS REPRESENTATIVE, CIVIL ENGINEER & LANDSCAPE 13 REQUIRED PER Cardno ®®® GENERAL NOTE A 17 RACK SPACE RACK SPACE RACK SPACE 6720 SW Macadam Ave uite 200, ill RACK SPACE RT(503)-419-9-2500 ACK SPACE RACK SPACE FOR OFOI FOR OFOI FOR OFOI Portland, 97219 FOR OFOI FOR OFOI FOR OFOI EQUIPMENT EQUIPMENT EQUIPMENT EQUIPMENT EQUIPMENT EQUIPMENT STRUCTURALI Catena Engineers 1500 NE Irving St., Suite 412 Portland, OR 97232 T(503)-467-4980 MECHANICAL ELECTRICAL & PLUMBING ENGINEER 2 2 Glumac 16 1 3 1 3 1 16 FUTURE 16 1 3 1 3 1 16 900 SW Fifth Ave., Suite 1600 RACK Portland, OR 97204 T(503)-227-5280 REFERENCE EQUIPMENT TAGS TO COMMUNICATIONS EQUIPMENT ROOM FITTINGS SCHEDULE FLOOR FOOD SERVICE CONSULTANT Webb Foodservice Design MDF E116 - RACK ELEVATION - ROW A MDF E116 - RACK ELEVATION - ROW B TELECOMMUNICATIONS BACKBOARDS 3700 SE Lafayette Portland, OR 9720202 3 SCALE: 1/2" = 1'-0" 4 SCALE: 1/2" = V-0" 5 SCALE: NONE T(503)-236-8566 ACOUSTIC &AV CONSULTANT The Greenbusch Group 1900 W. Nickerson St., Suite 201 Seattle,WA 98119 T 206-378-0569 COST CONSULTANT Construction Focus 740 Almaden St. Eugene, OR 97402 T 541-686-2031 COMMUNICATIONS EQUIPMENT ROOM FITTINGS SCHEDULE ID DESCRIPTION SIZE INSTALLATION NOTES 1 FOUR-POST EQUIPMENT RACK 84"H X 19"W X 29" D ANCHOR TO CONCRETE FLOOR Q 2 TWO-POST EQUIPMENT RACK 84"H X 19"W ANCHOR TO CONCRETE FLOOR \CA -- -- — — — - C1 C -C3— — _- -- -C 106 - IC8 - 3 DOUBLE SIDED VERTICAL CABLE MANAGEMENT 84"H X 10"W X 8"D MOUNTED TO RACK C CB _ 4 TELECOMMUNICATIONS MAIN GROUNDING BUS BAR 20"W X 4" H X 114"D WALL-MOUNTED AT+18"AFF B - - _ - 5 TELECOMMUNICATIONS GROUNDING BUS BAR 12"W X 4" H X 1/4"D WALL-MOUNTED AT+18"AFF B o 6 UNIVERSAL CABLE RUNWAY 12"W WALL-MOUNTED AT+96"AFF D I III ( I I I I I I 7 SPACE RESERVED FOR PHONE/DATA SERVICE PROVIDERS 96" H x 48"W N/A 8 ACCESS CONTROL SYSTEM PANELS 9 RACK RADIUS DROP MOUNT TO CABLE RUNWAY E Y 10 FIBER DISTRIBUTION UNIT 4 RU RACK-MOUNTED F 11 FIBER DISTRIBUTION UNIT 1 RU RACK-MOUNTED F — — > — — — — — — 12 48-PORT CATEGORY 6A PATCH PANEL 2 RU RACK-MOUNTED 13 HORIZONTAL CABLE MANAGEMENT 2 RU RACK-MOUNTED G J 1T 14 POWER DISTRIBUTION UNIT(PDU) MOUNT TO RACK H 1 15 FIRE RETARDANT BACKBOARD 96"H X 48"W MOUNT TO RACK A 16 DOUBLE SIDED VERTICAL CABLE MANAGEMENT 84"H X 6"W X 8"D MOUNTED TO RACK C 17 HORIZONTAL CABLE MANAGEMENT 1 RU MOUNTED TO RACK G NOTES: I I I I I I C F A REFER TO TELECOMMUNICATIONS BACKBOARD DETAIL -- , B REFER TO GROUNDING AND BONDING EQUIPMENT SCHEDULE FOR ADDITIONAL INFORMATION JU I o — Rl j C PROVIDE WITH DUAL-HINGED DOOR ON EACH SIDE _ _ I 7 D SEE CABLE RUNWAY DETAILS FOR MOUNTING REQUIREMENTS AND ACCESSORIES 00 SA — — — — I I — — Q E PROVIDE AT ALL CABLE TRANSITIONS FROM RUNWAY TO VERTICAL CABLE MANAGEMENT I ! F TERMINATE ALL FIBER CABLING ON 12-STR LC-ADAPTER PANELS WITHIN FIBER DISTRIBUTION UNIT 3 _LinP G PROVIDE WITH DUAL-HINGED DOOR ON FRONT SIDE LIE 1 I 1 H 120V INPUT, MINIMUM NINE(9) 120V OUTPUTS-PROVIDE ONE PER RACK IRA �= M -- - SD - -- — — — — — — — _ I I _I I I I _ I —I I I _ L I — — DATE K SE I I I I I I I I I I (7)2"C. SLEEVES TO CORRIDOR SF 2=4 ---7 H EXISTING MDFT I I DFEW.T NMDF I I I I I I I I 1 11 11 T G _ = I III LLs 8 7 S G F HI — I I I I 1 1 1 15 SH — — — — — — E _ (TYP) 6 D I I I I I I I TIGARD TUALATIN SCHOOL DISTRICT C 1 I I TIGARD HIGH SM — — — — — — — — — _ �_� SPACE FOR — _R — 16 16 3— — — B B OFOI IT WORK SCHOOL 3 SPACE FOR DESK MODERNIZATION, SN __ — — — — — — — — � — + — FUTURE I I I I I I I 1 1 1 EQUIPMENT RACK SO - - - - - - - - - THEE I I 9000 SW DURHAM RD. TIGARD, OR. 97224 JOB N0: 16992.00 IIL ISSUE DATE: 04/18/2018 I I I II I I I I I I Jurisdiction Stamp Area I I I I I I I I I I I I 11 -- 14 13 211 10 9 8 7 6 5 4 3 2 1 IUA,2: TH I I I II TECHNOLOGY - MDF MDF PLANS � o S 1 S;S3.2� S5 S6 S7. 18 9.2 (S 1U 11) IS 1 2ES 141 �- P - - MDF E11 - ENLARGED PLAN w MDF .T1 MAIN FLOOR OVERALL FLOOR LAN TECHNOLOGY EXISTING 6 G 1 SCALE: 1/32"= 1'-0" 2 SCALE: 1/2" = V-0" 0—