Loading...
Plans (31) FPS2021 -00049 VED �,I I Y ul- i U;,Hu sWF, awyRd 3UILDING C VISION T..ua � ecY I I I I I 73319W Bridgeport &itlgeycrcq Village$(ddrytm l8 and?M U; i Rd,Tigard,OR 97224 :.ega?e�egepw ;rag. t..*: $. I I j :-.a 0 0 13 l 1 13 0 13 li o a 1 1 1 ❑ O o 0 0 0 I I I i I I O C c 13 p o 0 0 O COr S I � e r- 0 -- 0 1 I ° ' ° 0 1 i o r o o *PLUG 1 0 0 QE ' CITY OF TIGARD F111I o 0 Approved................................................... Contitionall {� CEILINGS ARE EXISTING AND ° For only thepwoek as described in: 0 0 o p o o ° ° ARE COVERED BY EXISTING --- AUTOMATIC SPRINKLER PERMIT NO. FPS207-1 -cxDo q( 1 I I I I o See Letter to: Follow..................................[ ] x -- -- --- --- � Attach............ . E o °0 0 0 0 ° ° ° ° Job Addres 7331 SW l3Rr�cT 20 QL ....................{ ] o Date:e 29: A o 1 i ❑ ❑ 1 o U'.. o o 0 0 0 o O o 0 - 0 01 1 - E A=ADD E=EXISTING P=PLUG _ - - - - - - - - - - - - - - - - - - - - - - - - - - NOTES: 1, ADD 1 SPRINKLER AND DEMO 1 SPRINKLER FOR NEW TENANT IMPROVEMENT. 2. NEW SPRINKLERS TO BE FED FROM EXISTING WET SYSTEM. 3. VIKING TO START AT EXISTING BRANCH LINES. 4. OVERHEAD IS COVERED BY EXISTING UNLESS SHOWN OTHERWISE. 5. ALL EXISTING PIPING, HANGERS, & SPRINKLERS TO REMAIN UNLESS SHOWN OTHERWISE. 6. ALL NEW PIPING TO BE BLACK SCHEDULE 40 WITH C.I. FITTINGS. 7. EXISTING PIPING, HEADS, AND HANGERS TO REMAIN UNLESS OTHERWISE NOTED. 8. VIKING'S SCOPE DOES NOT INCLUDE ANY RESPONSIBILITY, EITHER WRITTEN OR IMPLIED, FOR THE CONDITION OR CURRENT CODE COMPLIANCE OF ANY EXISTING SPRINKLER SYSTEM EXCEPT AS MODIFIED BY VIKING. THIS DRAWING IS THE PROPERTY OF VIKING AUTOMATIC SPRINKLER COMPANY. IT IS SUBMITTED IN CONFIDENCE AND IS NOT TO BE DISCLOSED OR UTILIZED WITHOUT THE WRITTEN PERMISSION OF VIKING AUTOMATIC SPRINKLER CO. REVISIONS ABBREVIATIONS GENERAL NOTES WATER FLOW INFO SPRINKLER SYMBOL DESCRIPTION WET STAMP PROJECT. MARK BY DATE DESCRIPTION AFF- CENTERLINE ABOVE FINISH FLOORSTATIC: KtK� BRIDGEPORT VILLAGE ATJ -CENTERLINE ABOVE TOP OF JOIST 1.ALL MATERIAL AND EQUIPMENT TO BE NEW AND UNDERWRITERS SYM STYLE MFG RESPONSE THD 'K' TEMP SIN# FINISH ESCUTCH. WRENCH QTY APPROVED. RESIDUAL: BOB-CENTERLINE BELOW BOTTOM OF BEAM SEATTLE BOISE 7331 SW BRIDGEPORT ROAD BOD-CENTERLINE BELOW BOTTOM OF DECK 2. PIPING DIMENSIONS ARE CENTER TO CENTER EXCEPT RISER& FLOWING: ® DRY PEND VIKING QUICK 1" 5.6 155° VK176 CHROME NONE 07297WIB 1 PORTLAND FIRE PROTECTION POCATELLO BOP-CENTERLINE BELOW BOTTOM OF PURLIN DIMENSIONS SHOWN THUSLY(1-6)WHICH ARE END TO END. @ 20 PSI: LONGVIEW MEDFORD TIGARD, OR 97224 BOJ- CENTERLINE BELOW BOTTOM OF JOIST 3. PIPING, HANGERS,AND EARTHQUAKE BRACING SHALL BE IN BTJ -CENTERLINE BELOW TOP OF JOIST ACCORDANCE WITH NFPA PAMPHLET NO. 13,APPLICABLE EDITION. DATE: VIKING AUTOMATIC SPRINKLER COMPANY CL - CENTERLINE OF PIPE,COLUMN,OR BEAM COJ-CUT ON JOB 4.JOINING OF PIPE AND FITTINGS,THREADED AND WELDED SHALL LOCATION: 3245 NW FRONT AVENUE FO - FIELD ORDER BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13. INFO FROM: PORTLAND, OREGON 97210 • 24 hrs. (503) 227-1171 CPLG-COUPLING 5. OWNER TO MAINTAIN 40°F MINIMUM IN LOCALITIES SUBJECT TO PUMP GPM: PUMP PSI: TYPE: OREGON CCB#64837 METRO LIC#2816 .WASHINGTON LIC At VI-KI-NA-S373NT BUNK BAR T FLEX-FLEXIBLE COUPLING FREEZING PROTECTED BY A WET PIPE SPRINKLER SYSTEM AND IN 1EH — — - — GOE-GROOVE ONE END CONTRACTWITH GOL-GROOVED WELDED OUTLET ENCLOSURES FOR DRY PIPE, DELUGE,OR ANY OTHER VALVES APPROVING AGENCIES DWG RELEASE DATES: GxG-GROOVE x GROOVE CONTROLLING WATER SUPPLIES. SSP EXISTING COORDINATION- Date Drawn: Drawn By: SHEET. 1 OF 1 GxP-GROOVE x PLAIN 6.STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORT THE Q SSU EXISTING P.E./PERMIT- 4/16/2021 BATEMAN . A POL-THREADED WELDED OUTLET SPRINKLER PIPING IS THE RESPONSIBILITY OF THE OWNER FABRICATION- TOTAL SPRINKLERS SHOWN ON THIS SHEET 1 Scale. Job No. TOE-THREAD ONE END AND/OR HIS STRUCTURAL REPRESENTATIVE. CONSTRUCTION- — TxG- THREAD x GROOVE TOTAL SPRINKLERS REQUIRED ON THIS CONTRACT 1 As-BulLrs- 1/8 - 1 -0 WO-4039