Loading...
Plans (24) BUP2021 -00314 OFFICE COPY RECEIVED DEC 14 ' GENERAL NOTES CITY OF TIGARD INC DIVISION I. THESE PLANS FOR TENANT IMPROVEMENT ONLY, S_ DIMENSIONS ARE FROM FACE OF FINISH MATERIAL. E E gF.DANIEL YOUNG 2. THE PROJECT DOCUMENTS ARE OF LIMITED SCOPE, S. PATCH AND REPAIR ALL EXISTING WORK DAMAGED BY E PREPARED BY THE ARCHITECT AT THE OWNER'S REQUEST NEW WORK TO EXISTING CONDITION OR NEW CONDITION, ' TO ESTABLISH MINIMUM GUIDELINES FOR CONSTRUCTION OF WHICHEVER IS APPROPRIATE. E ( PORTLAND,OR THE PROJECT IN COMPLIANCE WITH THE APPLICABLE E 0 � GOVERNING BUILDING CODES AND REGULATIONS. WHERE 10.EACH SUB-CONTRACTOR MUST REFER TO DIAGRAMMATIC MATERIALS, ASSEMBLIES, EQUIPMENT, FIXTURES, AND PLANS AND SECTIONS AND MUST COORDINATE THEIR WORK I OF SYSTEMS ARE NOT SHOWN DIAGRAMMATICALLY, IT 15 THE WITH ALL TRADES TO AVOID CONFLICTS. �IQE �� RESPONSIBILITY OF THE GENERAL CONTRACTOR TO 06 OLF. • ISO 05 OLF. • I5m I DETERMINE SPECIFIC LOCATIONS, PROVIDE SPECIFIC II. DOOR HARDWARE SHALL MEET THE REQUIREMENTS OF 139 SF. / I50 139 SF. / I50 E MATERIALS AND DETERMINE CONSTRUCTION DETAILING, OSSC SEC. 10043 AND SHALL BE EITHER A LEVER OR • 1 OCCUP. • I OCCUP. ALL IN COMPLIANCE WITH APPLICABLE BUILDING CODES, PANIC TYPE REQUIRING ONLY A SINGLE MOTION TO OPEN. E 00 ^� REGULATIONS, AND INDUSTRY STANDARDS FOR MATERIALS KEY-LOCKING HARDWARE MAY BE USED ON THE MAIN N AND METHODS OF INSTALLATION. 17 IS THE CONTRACTOR'S DOOR OF B, F, M OR 5 OCCUPANCIES ONLY, WITH THE r- RESPONSIBILITY TO ASSURE THAT ALL CONSTRUCTION IS IN UNLOCKED DOOR FREE TO SWING WITHOUT OPERATION OF COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS. ANY LATCHING DEVICE AND A SIGN READING "THIS DOOR ■ JJ N MUST REMAIN UNLOCKED DURING BUSINESS HOURS" 3. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL PLACED ON OR ADJACENT TO THE DOOR 4 -0 O O MEANS, METHODS, TECHNIQUES AND SEQUENCES OF I bA'n CONSTRUCTION INCLUDING JOB SITE SAFETY. THE 12. PROVIDE TEMPERED GLAZING AT WINDOWS 4 RELIGHTS E4 ARCHITECT HAS NO RESPONSIBILITY FOR THE MEANS, PER SECTION 2406 E STATE OF OREGON STRUCTURAL E E I 0 METHODS, TECHNIQUES OR SEQUENCES OF CONSTRUCTION SPECIALTY CODE. TOP OF RELIGHT FRAMES TO MATCH INCLUDING JOB 51TE SAFETY_ TOP OF DOOR FRAMES_ l E @ 'C 4. THE WORK UNDER THIS CONTRACT/PROJECT IS TO INCLUDE 13. VERIFY KEYING REQUIREMENTS WITH TENANT AND F-I -1 11041I ALL THE LABOR, MATERIALS, TRANSPORTATION, EQUIPMENT, LANDLORD. AND SERVICES NECESSARY FOR AND REASONABLY f H -{ I a INCIDENTAL TO THE COMPLETION OF ALL CONSTRUCTION 14. PROVIDE 311/2" UNFAGED BATT INSULATION AT ALL WALLS I WORK IN CONNECTION WITH THE DOCUMENTS. ADJACENT TO NEW TOILET ROOMS_ L J 5_ APPLICABLE CODES ON MATERIALS AND WORKMANSHIP 15. PROVIDE FIRE EXTINGUISHERS AS DIRECTED BY FIRE r- SHALL CONFORM TO THE UNIFORM BUILDING CODE AND MARSHALL AT WALK-THROUGH_ VN LI O � APPLICABLE STATE AND FEDERAL SAFETY ORDERS_ ALL t- REFERENCES TO CODES, SPECIFICATIONS, AND STANDARDS I6.MECHANICAL, ELECTRICAL AND PLUMBING BY SEPARATE cq 000 Op SHALL MEAN AND ARE INTENDED TO BE THE LATEST PERMITS, 4E ISC N EDITION, AMENDMENT AND/OR REVISION OF SUCH E E 0 REFERENCE STANDARD IN EFFECT. Il. MAINTAIN (PROVIDE) 1009. FIRE SPRINKLERS PER F.M_O. 4 I Mo LATEST EDITION OF NFPA PAMPHLET 013. OFFICEtau NF N 6. EACH SUB-CONTRACTOR (OR THE GENERAL CONTRACTOR 02 OLF_ • I50 I > f03 oLF. • 15 WHEN HE 1.5 PERFORMING SPECIFIC PORTIONS OF THE I8. FIRE SPRINKLERS TO BE LOCATED IN THE CENTER 2'-0" X � H 295 Sr-_/ I5m 165 SF_/ 15 ja WORK) IS CONSIDERED A SPECIALIST IN HIS RESPECTIVE 2'-0" CEILING TILES OR IN THE CENTER OF EITHER HALF OF ` • 2 OCCUP. • II OCCUP. O ;� FIELD AND SHALL, PRIOR TO PERFORMANCE OF WORK, A 2-'0" X 4'-0" CEILING TILE. U J I 3 r- NOTIFY THE GENERAL CONTRACTOR AND ARCHITECT OF ANY WORK GALLED OUT ON THE DRAWINGS IN HIS TRADE 19. CABINETS TO BE OF 3/4" MELAMINE CONSTRUCTION. \ I N THAT CANNOT BE FULLY GUARANTEED OR THAT DOES NOT EUROPEAN CONSTRUCTION (NO FACE FRAMES) ALL MEET CURRENT LOCAL BUILDING CODES_ EXPOSED EDGES TO HAVE EDGE BANDING. PROVIDE I (LO BLUM IBM5580 CONCEALED 125' HINGES AND BLUM 34 sDA z 1. THE CONTRACTOR SHALL VERIFY AND CONFIRM ALLb O << DIMENSIONS AND CONDITIONS SHOWN OR IMPLIED ON THE EXTENSION DRAWER SLIDES. 100 LB RATING AT FILE DRAWERS. 50 LB RATING AT ALL OTHER DRAWERS, BACK 70 I � �1 DRAWINGS AND SPECIFICATIONS AS WELL AS THE SPLASHES AT COUNTER TOPS TO BE CONSTRUCTED OF 31/4" O T PHYSICAL CONDITIONS OF THE SITE, NOTIFY THE MATERIAL. ALL EXPOSED SURFACES TO BE COVERED I _ I U 3mXe Q ARCHITECT OF DISCREPANCIES PRIOR TO START OF WORK WITH P.LAM. SUBMITTAL REQUIRED. CC7 � E >Y EQ. 0 EQ. Iai 111 LI SEE TENANT'S PROVIDED � Ul rFl � DRAWING AND NOTES O z u Z 0 AREA OFFYI L � FOR BRANDING - THIS WALL [z� FWORK C 0 ® ® I� , WAITI O M W 0 - - 00 1 OLF_ • 1 T_ L Jpq EAIG I ea.crop. 0 n O zn O j L 77F—qF7 100 EE I cn O U Lo FR 110 FIRE I W Q 0 m NORTH EXTINGUISHER F. WALL MOUNTED W ° w„�30 120 1Suln40 .� ,3 REFLECTED CEILING PLAN 14 4 '44" = 1._0.. NORTH L7LL J FLOOR PLAN I/4u suln 170 SUITE;55 CODE SUMMARY SCOPE OF WORK GENERAL BUILDING DESCRIPTION: GENERAL OFFICE TENANT IMPROVEMENT FOR NEW TENANT TO AN 12/01/21 NUMBER OF STORIES: 2 EXISTING (VACATED TENANT SUITE). ADD (1) FIRE SPRINKLERS: 100% COVERAGE CONFERENCE ROOM AND (1) SUPPLY ROOM. NORTH FIRE ALARM: YES BUILDING SIZE: 45,000 SFs OFFICE COPY 1 ST FLOOR KEY PLAN PREVIOUS OCCUPANCY: B (OFFICE) PROPOSED OCCUPANCY: B (OFFICE) CITY OF TIGAItD,, OCCUPANCY: NTYPE: III-B RENEWED FOR CODE COMPLIANCE NOT TO SCALE T eis TENANT SPACE 51ZE: 1,002 U SF.s OTC; OTC: ( � LEGEND ponAt Qolo i- nn L`} 20 GA. 311/2" METAL STUD BRACING TO EXISTING WALL TO REMAIN • EXISTING SPRINICL� Ap 130 ROOF STRUCTURE AT 6'-O" O.G. LOCATION , By; Date 1 ALTERNATING DIRECTIONS. FASTEN NEW WALL - 311/2" METAL STUDS g BRACE TO TOP OF STUD WK2) 05 24" O.C_ %" GYP_ BD_ EACH SIDE SHEET METAL SCREWS AT EACH END. ■ EXISTING HVAC RETURN BRACING TO BE PROVIDED WHERE VALIDITY OF PERMIT DISTANCE BETWEEN PERPENDICULAR EXISTING DOOR TO REMAIN THE ISSUANCE OF A PERMIT INTERSECTING WALLS OR HORIZONTAL EXISTING HVAC DIFFUSER BASED ON CONSTRUCTION j BRACING BETWEEN WALLS EXCEEDS V-011 O.C. DOCUMENTS AND OTHER EXISTING 2X4 18-CELL PARABOLIC FLUORESCENT DATA CODE OFFICIAL EVENT SUSPENDED CEILING FROM NEW 3'-0" - 8'-0" DOOR FIXTURE TO REMAIN REQUIRING THE CORRECTION a OF ERRORS. OSSC 105.4 F1 / ATTACH BRACE DIRECTLY m —rl��� TO STUD, EXISTING 2X4 18-CELL COPYRIGHT LAW [LO]]] PARABOLIC FLUORESCENT PROTECTS THE DUPLICATION GYP_ BD. EA_ SIDE LLLIJJJ FIXTURE TO BE REMOVED OF DRAWINGS WITHOUT THE OWNER'S CONSENT. // NEW (2) 2'-0" X 7'-0" RELOCATED 2X4 IS-CELL REUSE OF ARCHITECTURAL TEMPERED TEMPERED TEMPF�RED BI-FOLD DOORS. VERIFY PARABOLIC FLUORESCENT DRAWING WITHOUT A GLAZING GLAZING GLAZING — 3'1/2" SOUND BATTS HEIGHT FIXTURE COPYRIGHT RELEASE AT CAVITY IS PROHIBITED ® MODIFY EXISTING FIXTURE TO 24 3'-0" 3'-0" 3'-0" _ HOUR NIGHT LIGHT CIRCUIT 05A 21054 �_ _J EXISTING DUPLEX ELECTRICAL �p I 3624' .ECTAL STUDS E OUTLET TO REMAIN \ II LINEAR SLOT WALL WASH LED E EXISTING MUDRING AND PULL HILTI X-U WIRE TO REMAIN PAPS X " EMBED S0 EXISTING SMOKE DETECTOR TO 624" O.C. MAX. + EXISTING ELECTRICAL WHIP REMAIN n $ SWITCH 3 CONFERENCE ROOM - 103 2 EXIST. CABINET ELEV. TYP. WALL DETAIL 11 NOTE: HVAC DIFFUSERS 4 RETURNS AFIRE - Aml I1/2 - I 0 A - � 1/2 - 1'-0" _ 111/2 • 1 -0 NEW 4' STRIP LED SPRINKLERS SHOWN ONLY IN EXISTING II LOCATIONS FOR CONTRACTORS CONVENIENCE. II CONTRACTOR TO RELOCATE HvAC DIFFUSERS 4 u RETURNS AND FIRE SPRINKLERS TO SATISFY BUILDING, MECHANICAL AND FIRE CODE. OF I