Loading...
Plans (21) BUP2021 -00254 OFFICE COPY 00 RECEIVED 00 SEP 2 3 2021J N _j M CITY OF I IGARD � BUILDING DIVISION M o FULL POT L HRT TENANT IMPROVEMENT ENTIA FULL POTENTIAL HRT Off ICIE COPY. r crry OP TIGAM __ Lu o C) REVIE FOR CUDB Approved: ] X — TIGARD , OR 97223 OTC: [ ] u o Permit#: '."�i +.' 4- a� Address: U Q O Suite M _ i�: 0 SYMBOLS AND FILL PATTERNS ' By.. 1D"`� ABBREVIATIONS GENERAL NOTES PROJECT CONTACTS u Q co IL 1/4:12 \ 0 DIAMETER HB HOSE BIBB 1 CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR OWNER: FULL POTENTIAL HRT CLINIC SURFACE SLOPE 1 TO PROCEEDING WITH THE WORK. ��� SLOPE PERPENDICULAR HR HOUR 6900 SW ATLANTA ST.,SUITE XXX ED A 2 DIMENSIONS TAKE PRECEDENCE OVER DRAWINGS.DO NOT SCALE DRAWINGS. TIGARD,OR 97223 WALL ASSEMBLY AFF ABOVE FINISH FLOOR ID INSIDE DIAMETER NOEIFY THE ARCHITECT OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH TEL:(971)319-4636 FAX:(XXX)XXX-XXX -- STUD SIZE AP ACCESS PANEL INS INSULATE(D), INSULATION 3 CONTRACTOR IS RESPONSIBLE FOR CONSTRUCTION MEANS AND METHODS. ATTN:CRYSTAL HALL, CLINIC OPERATION DIRECTOR W SCOTT D COMBS A3AX WALL TAG ACC ACCESSIBLE INT INTERIOR 4 CONTRACTOR IS RESPONSIBLE FOR VERIFICATION AND COORDINATION OF EMAIL:CRYSTAL@FULLPOTENTIALMEN.COM � ACT ACOUSTICAL TILE SUBCONTRACTOR'S WORK, COMPLIANCE WITH THE DRAWINGS AND V��-� ��sr- a" �T ADD ADDENDUM JAN JANITOR SPECIFICATIONS,ACCURATE LOCATION OF STRUCTURAL MEMBERS,AND ARCHITECT: CLARK/KJOS ARCHITECTS THE ISSUANCE OF A PI=E NIPT PORTLAND, OREGON -- MODIFIER AIC AIR CONDITIONING JT JOINT OPENINGS FOR MECHANICAL,ELECTRICAL,AND MISCELLANEOUS EQUIPMENT. 621 SW ALDER ST.SUITE 700 BASED ON CONSTROCTION ALT ALTERNATE 5 CONTRACTOR SHALL VERIFY DIMENSIONS AND CLEARANCES FROM PORTLAND, OR 97205 DOCUMENTS AND OTHER � 0e, AL ALUMINUM LAM LAMINATE(D) MANUFACTURER PRIOR TO THE CONSTRUCTION AND INSTALLATION OF ALL TEL:(503)224-4848 DATA SHALL NOT PREVENT. OF EQUIPMENT,FURNISHINGS,AND ACCESSORIES. FAX:(503)224-7116 THE CODE OFFICIAL FROkl AB ANCHOR BOLT LAV LAVATORY OATTN:ROBBIN GRAY,ASSOCIATE 1 KEYNOTE ANDD ANODIZED LH LEFT HAND 6 CONTRACTOR IS RESPONSIBLE FOR THE COMPLETE SECURITY OF THE SITE EMAILROBBINGRAY@CKARCHCOM REQUIRING THE CORRECTION : . DURING CONSTRUCTION AND UNTIL PROJECT COMPLETION. OF ERRORS. OSSC 105.4 ARCH ARCHITECT(URAL) LW LIGHTWEIGHT 7 CONTRACTOR SHALL LOCATE AND PROTECT EXISTING UTILITIES,WHETHER OFDOOR SCH PROVIDE OINDICATED AUTO AUTOMATIC MGR MANAGER 8 OVDE BACKING, IL GS OR NOT. REOCKIING,OR STRAPPING AS REQUIRED FOR GRAB BARS, PROJECT DESCRIPTION DOOR TAG BATT BATT INSULATION MH MANHOLE SHELVING,EQUIPMENT,HANDRAILS,ACCESSORIES,AND CABINETS. BM BENCH MARK MFR MANUFACTURE(R) 9 COORDINATE LOCATIONS OF IN-WALL ITEMS TO AVOID BACK TO BACK TENANT IMPROVEMENT OF EXISTING OUTPATIENT CLINIC A-1 FINISH TAG BIT BITUMINUS MO MASONRY OPENING INSTALLATION. BOL BOLLARD MAX MAXIMUM 10 ALL SAFETY GLAZING SHALL BE PERMANENTLY LABELED WITH THE B.O. BOTTOM OF MECH MECHANICAL MANUFACTURER'S NAME AND TEST APPROVAL INFORMATION. WINDOW TYPE- BLDG BUILDING MTL METAL 11 ALL WORK IN THIS BUILDING IS TO BE PERFORMED UNDER THE CITY OF REF WINDOW SCH THE RD PERMT TI ALROTRAR DESIGN BUILD PERMITS ARE R IIE TAKEN OUT AWLL BE ISSUED OR DRAWING INDEX W1 BP BUILDING PAPER MP METAL PANEL WINDOW TAG MIN MINIMUM SEPARATE PERMITS UNDER THE MASTER PROJECT NUMBER. CEILING MATERIAL CLG CEILING MISC MISCELLANEOUS 12 MECHANICAL WORK IS PROVIDED THROUGH A CONTRACTOR DESIGN BUILD -GENERAL- ACT-1"� CTR CENTER MOD MODULAR SYSTEM,MECHANICAL WORK INDICATED IN THESE DOCUMENTS IS FOR CEILING TAG CT CERAMIC TILE MRGB MOISTURE RESISTANT GYPSUM WALL INFORMATION ONLY.MECHANICAL CONTRACTOR IS TO FIELD VERIFY ALL GO.01 GEN.NOTES,SYMBOL,ABBRE.&FINISH CODE z CEILING HEIGHT ABOVE CLR CLEAR(ANCE) BOARD EXISTING CONDITIONS AND PROVIDE ENGINEERED DRAWINGS TO MEET THE G1.01 FIRE AND LIFE SAFETY FINISHED FLOOR-ALL CCN CLOSED CIRCUIT N DESIGN DEPICTED IN THESE DOCUMENTS AND ALL CITY OF TIGARD BUILDING CEILINGS 9'-0"UNLESS TIGARD CODE REQUIREMENTS. REQUIREMENTS FOR DESIGN UCTOR IS TO MEET ALL CITY ILD PROJECTS,AND OF - - COL COLUMN NOM NOMINAL DEMOLITION uj OTHERWISE NOTED. CONC CONCRETE N NORTH SUBMIT PROJECT TO CITY OF TIGARD.MECHANICAL DESIGN BUILD DRAWINGS CMU CONCRETE MASONRY UNIT NIC NOT IN CONTRACT SHALL BE SUBMITTED,AND APPROVED BY THE OWNER AND ARCHITECT, D1.01 DEMO PLAN-LEVEL 2 pm Name ELEVATION TAG Elevation CONST CONSTRUCTION NTS NOT TO SCALE PRIOR TO ISSUING TO THE CITY OF TIGARD FOR PERMIT. CONT CONTINUOUS, CONTINUE 13 EXIT AND EGRESS LIGHTING SYSTEM ARE TO BE INSTALLED TO MEET THE uj CFCI CONTRACTOR FURNISHED,CONTRACTOR OC ON CENTER(S) PLAN S INDICATEDINAPPLICABLE DOCUME CURRENT CODES FOR PRESCRIPTIVE LIGHTING PATH. EGRESS Room Name INSTALLED OPP OPPOSITE -ARCHITECTURAL- ARCHITECTURAL- 10 ROOM TAG CJ CONTROL JOINT OD OUTSIDE DIAMETER 14 MAINTAIN EXISTING BUILDING FIRE AND LIFE SAFETY SYSTEMS INCLUDING, O 150 S CG CORNER GUARD OH OVERHEAD BUT NOT LIMITED 70 SPRINKLER SYSTEMS,SMOKE EVACUATION SYSTEMS, A2.01 FLOOR PLAN LEVEL 2 ROOM NUMBER EXITING SYSTEMS AND EMERGENCY ANNUCIATION SYSTEMS. CF CUBIC FOOT OFCI OWNER FURNISHED, CONTRACTOR 15 ALL WORK SHALL CONFORM TO APPLICABLE BUILDING CODES AND A3.01 REFLECTED CEILING PLAN-LEVEL 2 INSTALLED ORDINANCES, AS MODIFIED FOR THIS BUILDING ON RECORD AT THE DRAWING REVISION DP DAMPPROOFING OF01 OWNER FURNISHED,OWNER INSTALLED CITY OF TIGARD. IN CASE OF CONFLICT WHERE THE METHODS OR STANDARDS A5.01 INTERIOR ELEVATIONS 1 DEMO DEMOLISH/DEMOLITION OF INSTALLATION OF THE MATERIALS SPECIFIED DO NOT EQUAL OR EXCEED om DMT DEMOUNTABLE P PAINT(ED) THE REQUIREMENTS OF THE LAWS OR ORDINANCES,THE LAW OR ORDINANCE DRAWING NUMBER DEP DEPRESSED PTD PAPER TOWEL DISPENSER SHALL GOVERN.NOTIFY ARCHITECT OF CONFLICTS. PTN PARTITION 16 IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY EXISTING CONDITIONS. 1 DTL DETAIL NO ALLOWANCE WILL BE MADE FOR UNFAVORABLE CONDITIONS OR EVENT (:A7.01 ,'r CALLOUT DIAG DIAGONAL PERF PERFORATE(D) WHICH MIGHT HAVE BEEN DISCOVERED THROUGH A THOROUGH SHEET NUMBER DIA DIAMETER PLAM PLASTIC LAMINATE EXAMINATION OF THE SITE.CONTRACTOR SHALL ASSUME FULL DIM DIMENSION PWD PLYWOOD RESPONSIBILITY FOR THE CONSEQUENCES OF ACTING ON CONCLUSIONS -INTERIOR FINISHES- BUILDING SECTION DW DISHWASHER PSF POUNDS PER SQUARE FOOT DRAWN FROM INFORMATION AVAIYBLE AT THE TIME. 12.01 FINISH PLAN-LEVEL 2 1 DISP DISPENSER PSI POUNDS PER SQUARE INCH A1.01 DIV DIVISION PT PRESSURE TREATED DR DOOR WALL SECTION DA DOUBLE ACTING QT QUARRY TILE -EQUIPMENT- Z 1 DN DOWN A1.01 DS DOWNSPOUT RAD RADIUS Lu DWR DRAWER REF REFRIGERATOR 1 DRAWING NUMBER DWG DRAWING(S) REQ REQUIRED 4 A3.00 2 EXTERIOR ELEVATION DF DRINKING FOUNTAIN RA RETURN AIR DEFERRED SUBMITTALS It REV REVISION(S), REVISED SHEET NUMBER EA EACH RH RIGHT HAND 1. FIRE SUPPRESSION SYSTEM J 3 RD ROOF DRAIN 2. FIRE ALARM AND DETECTION SYSTEM E EAST 1 ELEC ELECTRIC(AL) RM ROOM 3.MECHANICAL PERMIT DRAWINGS 4.ELECTRICAL PERMIT DRAWINGS DRAWING NUMBER EP ELECTRICAL PANEL RO ROUGH OPENING s' \\ 4 A3.00 )2 INTERIOR ELEVATION EL ELEVATION S � EMER EMERGENCY CHED SCHEDULE SHEET NUMBER EQ EQUAL SEC SECTION 3 EQUIP EQUIPMENT SAM SELF ADHERED MEMBRANE -- DIMENSION TO FACE OF FRAMING, EXH EXHAUST SV SHEET VINYL w FACE OF CONCRETE, GRID (E) EXISTING SIM SIMILAR .� 1" LINE, OR AS NOTED. EXP EXPANSION SC SOLID COREFM 1 114" EJT EXPANSION JOINT S SOUTH W EXP EXPOSED SPEC SPECIFICATION(S) C') ow SFRM SPRAY APPLIED FIRE RESISTIVE O cuCV CLEAR DIMENSION TO FINISH FACE ORAS EXT EXTERIOR NOTED MATERIAL O C CV F.O. FACE OF SQ SQUARE M NORTH ARROW FRP FIBER-REINFORCED PLASTIC STD STANDARD Q FGL FIBERGLASS STL STEEL PROJECT NORTH(SEE CIVIL FORFF FINISH FLOOR STR STRUCTURAL J 0 TRUE NORTH) FIN FINISH(ED) SUPP SUPPLEMENT,SUPPLY J cn -6 FA FIRE ALARM FE FIRE EXTINGUISHER TKBD TACKBOARD (E)98.75' EXISTING SPOT ELEV TEL TELEPHONE FEC FIRE EXTINGUISHER CABINET FHC FIRE HOSE CABINET TV TELEVISION CO 98.75' NEW SPOT ELEV FT FIRE TREATED TEMP TEMPERED FP FIREPROOFING T&G TONGUE AND GROOVE FD FLOOR DRAIN, FIRE DAMPER TO TOP OF ASPHALTFLR FLOORING) TOC TOP OF CURB OR CONCRETE FLOUR FLOURESCENT TOF TOP OF FRAMING �7 u CONCRETE FAF FLUID APPLIED FLOORING TOW TOP OF WALL .:':m FTG FOOTING TB TOWEL BAR EARTH FND FOUNDATION TS TUBE STEEL i i ii i i TYP TYPICAL GLASS GALV GALVANIZED GA GAUGE UNO UNLESS NOTED OTHERWISE CL..ea �O 0c)00 roc GRAVEL GL GLASS,GLAZING GB GRAB BAR VB VAPOR BARRIER GYP GYPSUM VERT VERTICAL L1- :.=;. GYPSUM BOARD GYP BD GYPSUM BOARD VG VERTICAL GRAIN GWB GYPSUM WALL BOARD VCT VINYL COMPOSITION TILE INSULATION ACOUSTICAL VICINITY MAP HDW HARDWARE WC WATER CLOSET ISSUE DATE: 09.20.21 INSULATION BATT HWD HARDWOOD WH WATER HEATER HDR HEADER WP WATERPROOF(ING) - -- - - _ - - - _.__ _ __ REVISIONS: INSULATION-RIGID HTG HEATING WS WATERSTOP HVAC HEATING,VENTILATING,AIR WRB WEATHER RESISTIVE BARRIER 690►►ARU0 SryryY Y ATLANTA ST. INSULATION SEMI RIGID CONDITIONING WWF WELDED WIRE FABRIC TIGARD,HT HEIGHT W WEST , OR 97223 MASONRY-BRICK HC HOLLOW CORE W/ WITH HM HOLLOW METAL W/0 WITHOUT MASONRY-CONCRETE BLOCK HOR HORIZONTAL WD WOOD METAL-ALUMINUM � - - LESSER CITY METAL-STEEL PARK UJIW o SAND C) �- M *WOOD-BLOCKING PACIFIC HIGHWAY/ cr_ rn 99W Q'" *WOOD-CONTINUOUS ` 0 N C!� O 04 = WOOD-FINISH 15 WOOD PARTICLE BOARD U GEN. NOTES, SYMBOL, wooD PLYWOOD ABBRE. & FINISH CODE - BEAVERTON TIGARD ui HIGHWAY o' U) GOmOl Y PROJECT NO.. 21043 Y PROVIDE ADDITIONAL WALL 12" � °O FINISH BEHIND PTD FORA HORN/S STROBE CODE SUMMARY _ GENERAL NOTE_ S_ �n U00 FLUSH MOUNTING SURFACE ® NON-ACCESSIBLE (BOTTOM OF BOX) PROJECT NAME: FULL POTENTIAL HRT-TENANT J AT COUNTERTOPS ----- TOP OF WALL PHONES IMPROVEMENT 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THAT ALL 04 N SDS ®ACCESSIBLE ® {� TRADES ARE THOROUGHLY FAMILIAR AND COMPLY WITH THE Q J o PTD � - ----1-AT COUNTERTOPS PULL STATION ADDRESS: BUILDING E,6900 SW ATLANTA ST,LEVEL 2 REQUIREMENTS LISTED IN THE FIRE AND LIFE SAFETY STANDARDS" Lo o TYP 40"TO CONTROLS AND (TOP OF BOX) SE PUYALLUP,WA 98372 (FESS) 20% DISPENSER OPENING48" O° 5. THE CONTRACTOR SHALL FIELD VERIFY THE CONDITION OF THE U? o (MAX.( �, g AT ALL OTHER EXISTING FLSS SYSTEMS IN THE AREAS OF WORK THAT MAY REQUIRE a FRONT REACH AND 48"SIDE d '"� - LOCATIONSINCLUDING OWNER: OREGON EDUCATION ASSOCIATION ( UPDATING.AREAS INCLUDE(BUT ARE NOT LIMITED TO)THE REACH) r-° OPEN WORK COUNTERS) FOLLOWING: CODES: 2019 IBC �� U G SOAP DISPENSER ELECT. OUTLETS LIGHT SWITCHES TELE/DATA CONN. SIGNAGE NFPA 101-CHAPTER 38 D.VERIFY THAT THE FIRE ALARM, EMERGENCY LIGHTING,AND O O PAPER TOWEL DISP. O COAT HOOK O (CENTER OF BOX) O (TOP OF BOX) O (CENTER OF BOX) O FIRE ALARM DEVICES O (CENTER OF BOX) EMERGENCY POWER IN THE AREA OF WORK CONFORMS TO THE FLSS LLJ OCCUPANCY: BUSINESS "ELECTRICAL STANDARDS"SECTION FOR THE OCCUPANCY TYPE i INDICATED ON THE FLS PLANS o � o NUMBER OF STORIES: 2 NOTES: 1)ALL DIMENSIONS ARE TYPICAL UNLESS NOTED OTHERWISE ON INTERIOR ELEVATIONS. - U-) N CONSTRUCTION TYPE: VB .: 2)WALL MOUNTED ACCESSORIES SHALL NOT PROJECT MORE THAN 4 FROM FACE OF WALL WHEN LOCATED BELOW 6-8'. = v) rn FIRE PROTECTION: FULLY SPRINKLERED U O cn J � � 1 TYPICAL MOUNTING HEIGHTS FIRE ALARM SYSTEM: YES N G1.01 1/4" = 1'-0" OCCUPANT LOAD OF FIRST FLOOR: 1/150 SF,BUSINESS AREAS=46 OCCUPANTS u Q to a OCCUPANT LOAD OF SECOND FLOOR: 1/150 SF,BUSINESS AREAS=46 OCCUPANTS BUILDING OCCUPANT LOAD 92 OCCUPANTS D A T� SQUARE FOOTAGE OF EACH FLOOR 6,872 SF � S-1 IDTT D �DI.1BS MINIMUM CORRIDOR WIDTH 36"WITH AN OCCUPANCY LOAD OF LESS THAN 50 " PORTLND, OROON DEAD END CORRIDOR DISTANCE ALLOWED 50 FT 0 Og� MAX.COMMON PATH OF TRAVEL(1006.2.1): 100 FT MAX.TRAVEL DISTANCE(1017.2.1): 300 FT FIRE RESISTIVE RATINGS:(TABLE NO.601,602 OF THE I.B.C.) BUILDING ELEMENT(>10' TYPE 1-A SEPARATION) STRUCTURAL FRAME 3 HOUR BEARING WALLS EXTERIOR 13HOUR INTERIOR 13HOUR NON BEARING WALLS AND PARTITIONS uu EXTERIOR 1 HOUR,IF<30'FIRE SEPARATION DISTANCE 0 HOUR,IF 40'FIRE SEPARATION DISTANCE INTERIOR 0 HOUR FLOOR CONSTRUCTION uj INCLUDING SUPPORTING BEAMS 2 HOUR AND JOISTS — — — — -- — — — — — — — NON BEARING WALLS AND PARTITIONS O IF _ r — — — — — — — --- INCLUDING SUPPORTING BEAMS 1.5 HOUR I I=> iI AND JOISTS o 1'-6" 'v 2'-0" S-0" � T-6" FRONT APPROACH,PULL LATCH APPROACH,PULL SIDE HINGE APPROACH,PULL SIDE HINGE APPROACH, PULL SIDE SIDE `54"MIN IF CLOSER IS PROVIDED F_- - - T_ 7 7T - - - - - -I 2'-0 1 0"fin 1 10 , CD (:_ - ")� '; -...._ . __.._...._._...._................_...__._.._.._.. _._. . -- &- ..... ._. _ __.__. .:- -_ .._ .-........ --- __ _...._ 1 _ �_ _ __ _ y-r uj - - - �- - - - - — ........ _ - - - - - - - _ ... FRONT APPROACH,PUSH SIDE LATCH APPROACH,PUSH SIDE HINGE APPROACH,PUSH SIDE n 'f 0 IF BOTH CLOSER AND LATCH 48 MIN IF CLOSER IS PROVIDED IF BOTH CLOSER AND LATCH ARE PROVIDED ;:-- ! 1 ARE PROVIDED '*48"MIN IF BOTH CLOSER AND LATCH ARE PROVIDED I Pi : MANEUVERING CLEARANCES AT SWINGING DOORSuj I` / 3 i n ' _ r_ co C'4 - s �'; 4%0" I ,4 a ID o co � Q z., CLEAR FLOOR SPACE FORWARD APPROACH PARALLEL APPROACH # I (6 o 2, 6„ I I __ w ..._ _.. ._.. .._.._._ ... ._.._._. u , 3 ... ._..,_-.. I , I / 1uj FORWARD APPROACH PARALLEL APPROACH IN ALCOVE IN ALCOVEt7, 0 2'-6 6 ` - - a n n r I ; . 1. , I— i ._ ISSUE DATE: 09.20.21 x —... REF REF FORWARD APPROACH PARALLEL APPROACH -��,; = I j .!_._._._. ,__. _'_____ '_ -_.._.—- .—.. T. .-_._._ \�` REVISIONS: IN ALCOVE IN ALCOVE } i 1. z ... rcuvae.u, 3'-0"MIN. _ € f - z - CONTROLS " Ixg , y ALIGNED 0 l'-7" EQ EQ MAX. , -� 0 4'-0" 4'-0" 0 M N r; 3} I I C . CLEAR FLOOR SPACE AT CLEAR FLOOR SPACE AT CLEAR FLOOR SPACE AT g ` LAVATORIES REFRIGERATOR SHOWER _ .. ,� ----� — _ . — — — — — — — — — _ — — r _.. _.... _... - — — ____. .__...._x_.____ _.._..___._ ._...—_ ____..__ ...._. .. _____ _...___. .._ ._. __._ _....__.�_ _...L.__......_... a,a � .+... ..__. LL — J� 9. N (SIDE APPROACH ONLY) CLEAR FLOOR SPACE - �-- t _ a J 0 U FIRE AND LIFE SAFETY U U s_� TYPICAL ADA CLEARANCES 2 LEVEL 1 - OCCUPANCY LEVEL 2 - OCCUPANCY w G 1.01 1/411 - 1 -0 Gto1 1/811 ly-011 U Q O Y QY J1 PROJECT NO.' 210431 U GENERAL NOTES v, Uco11. co 4 3 2 1 --- ---- ---- -- --- co 1. CONTRACTOR SHALL VERIFY LIMITS OF DEMOLITION WORKO J N 2. THIS DRAWING IDENTIFIES ONLY MAJOR WORK FOR DEMOLITION AND REMOVAL. ALL AREAS OF DEMOLITION SHALL BE CLEARED OF ,C) ALL ITEMS MAJOR AND MINOR TO RECEIVE INSTALLATION OF NEW CONSTRUCTION AND FINISHES U) o 3. SEE REFLECTED CEILING PLANS FOR WORK THAT MAY IMPACT DEMOLITION i E- 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS,MEMBER D - - - SIZES AND CONDITIONS PRIOR TO COMMENCING WORK.ALL +�► U DIMENSIONS OF EXISTING CONSTRUCTION ARE INTENDED AS GUIDELINES ONLY AND MUST BE VERIFIED.REPORT ANY W - - .-----._............_ _ . .. --' ..._.---.._._....... - --'--.... ...._ ....._............. .- - ._.... _._-._ ..__......................__.. ...._ i .................. . ....... _.... _...... _.... _...... --. - -- _. .... . . _. _.._ - _._ ... __ _..._ - ND IN FIELD AND - '- ---- '- ":: '- --' - DISCREPANCIES BETWEEN DIMENSIONS FOU - - - - - - - - � DIMENSIONS ON DRAWINGS TO ARCHITECT 5. LOCATE ALL WIRES,PIPES,UTILITIES,STRUCTURAL MEMBERS,ETC. a) i PRIOR TO ANY DEMOLITION.CUTTING OF ANY ITEM WHICH IS NOT - r-�- a I o PART OF THIS PROJECT SHALL BE REPAIRED BY THE CONTRACTOR _ a' I -, AT NO ADDITIONAL COST TO THE OWNER,INCLUDING ANY TESTING _ OR SPECIAL OBSERVATION TO CORRECT THE PROBLEM 6. PATCH AND PAINT WALLS,FLOORS,AND SUBFLOOR TO MATCH U Q O jeo nD. 1 I EXISTING WHERE WORK HAS DISTURBED EXISTING CONDITIONS. -a D.2 j I 7. ALL EXISTING FINISHES ARE TO BE PROTECTED FROM DAMAGE. U) cu DAMAGED AREAS SHALL BE REPAIRED AT NO COST TO THE OWNER. N 0 D.4 p'a ENTRY € WORK I OFFICE 18. MAINTAIN 100%FIRE ALARM COVERAGE V Q n- 200 -- -- - - - -- - - - ' 202_ I 203 I I 9. EXTREME CARE SHALL BE TAKEN BY THE COTNRACTOR TO PROTECT ALL EXISTING AREAS TO REMAIN FROM DAMAGES THAT D.10 CONF. MIGHT OCCUR DURING DEMOLITION.THE CONTRCATOR WILL BE HELD RESPONSIBLE FOR ALL AREAS THAT HAVE BEEN DAMAGED ��Z - -- -- - -- I 1 1 - � _ I DUE TO INADEQUATE PROTECTION. C� _p -�_ P FTL I IC RE LEGEND �❑ �o EXISTING PARTITION TO BE REMOVED OF - - - - - - - - - - --� OFFICE EXISTING PARTITION III ; 18" � � � 18" 204 1 D.10 LJ U O HALL I D.4 EXAM22 I 214' I x- 1 - J 1 KEYNOTES I E 1 D.27 D.6 D.2 D.1 DEMO EXISTING PARTITION WALLS AND ALL RELATED 1 „ / - - - - - - - 18" ITEMS -- Z1, .YUSE. . .-.._ - -- -- I n D 3 DEMO CASEWORK AND ALL RELATED ITEMS • D.2 REMOVE CASEWORK AND SALVAGE FOR RES USE. 4e T - - - - - � - - - - - -1- - - - T - 1g" I I D.15 I L - 18 I I D.4 DEMO FLOORING,REFER TO SHEET FOR AREA OF NEW - -- -= - - FLOORING FOR EXTENT OF WORK.PREP FOR NEW Z L -- -- -- - J FLOORING AS REQUIRED. D.5 DEMO DOOR INCLUDING FRAME AND HARDWARE. uj HALL SALVAGE FRAME FOR REUSE AT NEW DOOR LOCATION I 208 D.6 DEMO DOOR AND HARDWARE,FRAME TO REMAIN. ID.7 REMOVE EXISTING STORAGE FURNITURE,SALVAGE FOR OFFI CE OFFICE RESALE. PROCEDURE 205 Lu z 215' D.4 z f ❑ I D.8 DEMO EXISTING FURNITURE/STORAGE. HALE 1;0ROOM I D.9 REMOVE WALL HUNG MAGAZINE RACK. t I 211 I I D.10 DEMO ELECTRICAL STRIP AT BOTTOM OF WINDOWS IN .i EXAM ROOMS ONLY. D.12 DEMO EXISTING PARTITION WALLS AND ALL ITEMS O D.4 REQUIRED FOR NEW DOOR OPENING. I D.27 ( � D.13 RELOCATE DUPLEX RECEPTACLE TO 42"AFF. EXAM EXAM : ' 1I D.14 RELOCATE DATA OUTLET TO 44"AFF. 18 18" D 4 ' D.15 REMOVE EXISTING STORAGE FURNITURE,SALVAGE FORom _ ,s i I T T REUSE IN MED LAB 233. I -- D.19 REVISE CEILING AS REQUIRED FOR DEMOLISHED WALLS 18"ID18•/ I AND NEW WALLS.SEE RCP SHEET A3.01 D.27 LIMIT OF FLOORING DEMO. .10 }; OFFICE _._.__._.__. I OFFICE II 2 6 206 HALL -- - '218 F I - D.8 18" i uj I ` II J IIMEN BREAK II Q --. I :233 i r uu _.......... __ ❑ 1 ........... JAN I - 223 _ I � N HALL i.>.. ........ O 234 II I 11cu r* I I ❑ if D.4 WOMEN ❑ u II L.L Q I � 222 c I � 0 II FILE BREAK I II I 219 D.9 E O II II LL LL F T- UNISEX .._. I i 1224 h_ i W c+ SERVER STUDY VEST ^� GI 220 232 - I 235! ........_.r- 1 i II , j I HAIL 2261 ❑ I LL, I ' j1 ._ ___._.__.._ ISSUE DATE: 09.20.21 11 i II �.. _. _._ ._.. _ _ _ REVISIONS. +. -.. . . ... .._ _ ..... _. i ❑ I ❑ III 1 I 1i II OFFICE OFFICE OFFICE OFFICE , OFFICE II OFFICE OFFICE II a 237 236 ' , 227 228 I 229 I I 230 231 1 E 1. 1 I D.1 I I N jl i I ' E I I N �--- - - - - - - - - - - - - - - - � - - - - - - - _- ._.__ E `_._.....__ - - - - - _ _. - - - - - �- - - - - - - - - - - - - { __ _.__..__.-_-____..___.-- - - �- - - - - - _ _ _ - _ - - - _ _ _ _ - - H _4 CL DEMO PLAN- LEVEL 2 L.0 f I j. �L i Lu � II Q CIO Dl ■ Ol Nz DEMO_ LEVEL 2 of (�10�i� 1/4" PROJECT NO.: 21043 - - J `- U GENERAL NOTES00 co 4 3 2 1 -- ---- ----- --- qT - 1. ALL CEILING HEIGHTS ARE RELATIVE TO EXISTING. J N 2. FIELD VERIFY EXISTING CEILING LAYOUTS PRIOR TO ANY WORK. J o 3. SUSPENSION SYSTEMS FOR NEW AND EXISTING SUSPENDED Lo GYPSUM BOARD CEILINGS SHALL BE MODIFIED TO FRAME AROUND - ai CEILING INSTALLED ITEMS to o 4. WALLS ARE SHOWN FOR REFERENCE.WALLS SIT JUST BELOW d -- - CEILINGS �- '� 5. REMOVE EXISTING CEILINGS WHERE NEW CEILINGS ARE SHOWN TO BE INSTALLED. U F16. FOR TOP OF WALL DETAILS AND HEIGHT OF GYP BOARD ON WALLS, _ __ __ __ _ -__ _ ____ . SEE PLANS, PARTITION TYPES,AND DETAILS. �/ LU _ - -- i _ _ w . .. D,......1....6f. .. _...................1... is _..._..........._.._._I,!I......_. ........... ...!...... II j i..... .... . ._. _ . .._......_:� — zo3 .i... _ - _ .. is — J U C)RECESSED FIXTURES ARE TO MAINTAIN RATINGS WHERE LOCATED ::::7:771.. _ ........_ .. . _ _ ...... IN RATED CEILING ASSEMBLIES. .._.... _.. - -_.................._... ._..._........ __...._.._........_....._ .......... ............ _ _ .. ....._..... —. ..... . ._......_..._.. ._ ... .........,.... _ .. — . ._ .. .. .. .... — .. . . .. ....._ __. ................-- - . ......__..... .. ........ ...... _ ._ _ _..__ ... .. .Mi _..........._._.. .. ... . . .Z LEGEND I � .fan.�+ �ca1 � aE TRK OFFICE V Q RY cJJoNNza`�' GHF ! I1!r!y'ilI1,r1I_ .❑-2222...p..11-- 11c !� tII : _IiF ..—..:.2_:._1..2._—S1Ii!!II1;!I!;II!�I!!i�!!!I• -�- Y - -_- ...._. — ._.--...._..�._ '._--...i. _ _ _.D.21) .-._.. .1 21'__) 'I I.D_—.._ ..._..__.4__........._ ...._...\ 2— ...._/._W._.' .__.. I_=—_-_._._..__.�II..___I1I,....JJ._,...�•._ _.•• L I EI _-IIX-v---•2\_ _ - 1_ I i 1 !'IIiIIiI! _4 ; - IiIIiI.I'II !! /._ Ij —___❑_22�_00-__56-_--_ . ,iI 1 � _ :II:I• �tfiIp3 �_.....i1! .._.. - KEYN� CIG TA G CEILING HEIGHT20a 2 CON 2n � EXISTING GYPSUM BOARD CEILING Z_ � TT Lf. D.20 ' a- �Q E c �2 ID.2 IPORTLti , OREGGf d ................ID.24) !D.26) ) C.18EXISTING WOOD CEILING FFIC ID.2ID.20) EXISTING ACT-1:"2x4"SECOND _ =1 LOOK(FALSE 2X2 TILE)HALL x ) ID.19) EXISTING 2 x 2 DROP-IN FIXTUREF I EXAM EXISTING RECESSED DOWNLIGHT OFFIC EXISTING RETURN .............. ... H AL PROCEDURE EXISTING SUPPLY HALL —ROOM 1❑7 RECESSED DIRECTIONAL u DOWNLIGHTOFFICE PENDANT LIGHTEXAM: EXIT SIGN OFFICE D.18 RELOCATE SPRINKLER AS REQUIRED FOR NEW WALL. SEE RCP SHEET A3.01 D.19 REVISE CEILING AS REQUIRED FOR DEMOLISHED WALLS AND NEW WALLS SEE RCP SHEET A3.01 PFFIC D.20 RELOCATE EXISTING LIGHT AS SHOWN ON RCP SHEET A3.01. uj D.21 RELOCATE EXISTING GRILL AS SHOWN ON SHEET A3.01. D.22 D.24 RELOCATE SPRINKLER HEAD FOR NEW GYP CEILING AT ........ _ D.25 LEREQUIRED FOR NEW DROPPED GYP _ _.... ......... CEILING.SEE RCP SHEET A3.01.. D.26 RELOCATE EXIT SIGN _ ..... 221 _ uu............ _ .._..._ __ cn Fm UJ ............................... ..... ..... _. .. .... JAN ............. �_ co .. ... 2❑23 A_ H ...... - - _ ..........._. ---------------- .......................... . ...... _ . _. .... . .. . ..................._....._.__....._........ . ......................_._..........-_. _._.._. .. ......... .... _ .......... ......................... WOM ------ - . ...._... ...... ..._...... . . .. _-- ..._....__..........__ . _. __ ..... -- -- ._.... - . _ _......._ _..... .._..._...._._ .... .........................- -_............- . 219FILBREAK . L � ___ _ STUDY ISfX_ 22224 AA z VEST- ..__.. uj - HALL 226 � _._...._ _ :_ ......._......._ _........._.. ._..... _ ISSUE DATE: 0te0r(9�a.2 0 N.L2(k1y1 REVISIONS OFFICE OFFICE OFFICE 230 [2 31] OFFICE ID.19) ID .19) U 3 r. r1ID.20) II D.20) W I Mo DEMO RCP w a o Dl ■ 02 Y 1 DEMO - RCP LEVEL 2 114 1 -0PROJECT NO.: 21043 , GENERAL NOTES - ARCHITECTURAL00 00 4 3 2 1 N J © 1. PERFORM ALL WORK IN ASCCORDANCE WITH ESTABLISHED N BUILDING STANDARDS FOR TEANNT IMPROVEMENTS J c i 2. ALL DIMENSIONS TO FACE OF STUD UNLESS OTHERWISE NOTED. ALL CEILING TERMINATE AT THE UNDERSIDE OF THE EXISTING ui SUSPENDED CEILING UNLESS OTHERWISE NOTED. (n o 3. MECHANICAL,ELECTRICAL AND FIRE PROTECTION SYSTEMS a INDICATED ARE FOR INFORMATION ONLY.THESE SYSTEMS ARE f SUB-CONTRACTOR DESIGN/BUILD AND ARE TO BE SUBMITTED ' --- - - UNDER SEPARTE PERMIT, UNDER THE MASTER PERMIT FOR THIS PROJECT. IT IS THE RESPONSIBILITY OF THE DESIGN/BUILD F1 SUB-CONTRACTOR TO OBTAIN THESE PERMITS. 4 Y LLJ ALL WALLS,DOORS,FLOORS,CEILINGS WITHIN THE LIMITS OF WORK o _ NOTED ARE TO BE PATCHED,SANDED AND PREPARED READY FOR A.4 WR _40 44" �; ; NEW FINISH SPECIFIED. H SHP !, A.5 )' 5. DOORS OR OPENINGS LOCATED BY A WALL AT A RIGHT ANGLE ARE - TO BE INSTALLED 4 INCHES FROM SAID CONDITION.THIS CONDITION _ o IS TYPICAL AND WILL NOT BE DIMENSIONED. RECEPTION i 201 9 6. PROVIDE EXIT SIGNS AND EMERGENCY LIGHTING SYSTEM IN T-P i '1 ❑ CONFORMANCE WITH CITY OF TIGARD REQUIREMENTS. U Q O ' i A5.01 2 WORK AREA CRYSTAL'S 7. ALLNEW AND EXISTING DOORS TO BE SOLID CORE FLUSH TO MATCH ..I ---------` - J WTD (A.13) (A.14) (A.15) (A.13) BUILDING STANDARD AND HAVE BUILDING STANDARD LEVER cn cv A.5 10 202 OFFICE TH/S - HARDWARE. N o 1 A5.01 3 PTD 203 8. UTILIZE ZERO VOC PAINT SYSTEMS,INCLUDING PRIMERS AND Q c� CHC I FINISH PRODUCTS. D _ 9. PROVIDE SOUND INSULATION IN ALL NEW WALLS EXCEPT FOR LOW PROCEDURE I, II • OR PARTIAL HEIGHT PARTITIONS. �\ -- �y i C CH DR 213 A.3 GENERAL NOTES - ELECTRICAL c� w SCOTT D C01�4BS � CHC 18" 18" Gti�--,3 1. ALL NEW ELECTRICAL OUTLETS TO BE MOUNTED AT+18 UNLESS ________ (A.20) NOTED OTHERWISE. PORTLAND, OREGON All, = 18" 2. ALL RECEPTACLES,SWITCHES AND COVERS TO BE BUIDLING STANDARD AND MATCH IN COLOR.FIELD VERIFY. OF Og PTD ^ 18" 3. ALL RECEPTACLES,SWITCHES AND COVERS TO BE BUIDLING ALIGN NEW WALL IA.12) A.1 STANDARD AND MATCH IN COLOR.FIELD VERIFY. CHR A.6 , �; W/EXISTING GLD ----------- HALL -- -------HALL CONSULT 2 ' 21z A.1 CH-R ❑ SHP 2 0" 214, �-- -------- ---- - --- - - • LEGEND CH-C WR ----------------- SHP �, o CONSULT 9 -.._ - H/S r� EXISTING PARTITION A.7 sHP - WR 242 CONFERENCE CH-C A5.01 8 CH-R ^ ^ NEW PARTITION E F-I � WALL ROOM EXISTING OUTLET T- ^ WR CONSULT 8 A.3 ❑ C (P`18 EXISTING 16" EXISTING SWITCH 241 A.6 CRT CRT `�" LD HIS GLD H/S 7 EXISTING DATA PORT I CHC CHC 77 ( .. -� 0 18" �... 41 . . A.7 T C CHC -_- 42 til NEW OUTLET " " 11 6 11 -4 NEW SWITCH ,CH-DR 6 T Cop JI ui jA^ CHC CH-DR • H 08 L OS NEW DATA PORT ❑ " DR. STRAIT cH R 7 PROCEDURE OFFICE �- ;- 5 -- -_. 205 __------ --._ Lu �._.._ I PROCEDURE HALL ` '` ❑ WR KEYNOTES 211 CHC CHC CHC CH-C 3 > 215 T_c BDFU ROOM 1s BDFU ROOM T c A.6 r A5.01 1 E� � Al NEW WALL.SEE DETAIL 1/A8.01 --- -- ----- --- 6 ] } A.3 INFILL WALL TO BE FLUSH WITH ADJACENT WALL. 42 /N i_ A5.01 19 SHP --' SHR USjH�P WR GL SHP H/S I i T-P i 18 210 H/S 209 A.4 WALL MOUNTED DISPLAYVERIFY LOCATION WITH " i WR «, `o H/S s 18" U ED D S SHELVES, - --- ----- ---------------- - ,� OWNER - A.6 t CHR GLD �p- A'6 A.5 WALL MOUNTED MONITOR,TYPICAL.VERIFY LOCATION WITH H/S � - G ' - OWNER. PTD H/S CH HALL WR GLD 42" SHP i GL PTD 18" A.6 VERIFY LOCATION OF EXAM ROOM ACCESSORIES WITH --- - - PTD --- 207 OWNER,TYPICAL(PAPER TOWELS,HAND SANITIZER,ETC) . A.7 WALL MOUNTED MONITOR ARM,TYPICAL.VERIFY LOCATION A.6 I L-- ! WITH OWNER.REQUIRES BACKING. SPA ROOM 4 ; Fm 4 216 4 1B PTD QUIET A.9 RELOCATED CASEWORK.PROVIDE FINISHED BACKING. ❑ _v _._,__.....i " ROOM A.10 RELOCATED FURNITURE FROM ROOM 211. 206 A.12 LOGO/SIGNAGE,VERIFY LOCATION AND HEIGHT(OFCI) Z A.13 CUSTOM RECEPTION DESK CHS A.14 WALL WITH TOP CAP/COUNTER Q 5 HALL A.15 FURNITURE DESK W/POWER AND DATA AT WALL -- ------ ------------ --�- 218 A.16 ,CH-DR 18" A.17 REPLACE LOCKSET WITH KEYED LOCK SET T-C A.5 A.4 ��+ �� - -: A.18 PROVIDE NEW NEW BUILDING STANDARD SOLID CORE DOOR ui F - -- - -- WITH BUTTS AND PASSAGE LATCH SET. A.19 PROVIDE T-0"X T0"WOOD FRAME, BUILDING STANDARD ELI- . � 18" REF ME r i 1 IA.10 SOLID CORE FLUSH DOOR,BUTTS AND LATCH SET. 1 6'-6" A.20 CUSTOM AND INSTALOLOBUILDING STANDARD BUTTS DAND LATCE WOOD HSET. 18° \ MED SUPPLY MEN 233 - ' J Fm -_- EQUIPMENT LEGEND ...:::........ lol s 1 HAIR(OF01) Lu y JAN" --^IA�6) -__ CH DR DOCTOR CHAIR(OF01) U7 ---- _ CH-R RECLINER CHAIR(OFOI) I 223 (0 01 4-+ .-_ .. ._ I CH-S SPA CHAIR(OFCI) W CRT CART(NEW,OF01) M - GLD GLOVE DISPENSER OFCI +r CV ...:.... ❑I T ) i- I H/S HAND SANITIZER STATION(NEW,OFCI) a t I I (OFCI) ) ) T PAPER TOWEL DISPENSER I WOMEN SHP SHARPS CONTAINER(OF01 Q ^ \ T C CONSULT TABLE(OF01) J BREAKROOM HALL 222 ---IA.16) \ / T-P ELECTRIC PROCEDURE TABLE(OFCI) O g) WR WASTE RECEPTACLE(OF01) J I ' �--"---"""--I WTD WATER DISPENSER, (OF01) IIco i( REF 18" 18,REFum i C ........X' --....... -......._..._...-.. f .........._..._ _ ................ ........ .. .�.... ._......... ....... ._ _ ....__ .____.....___ .._.'' _--_.._.._.... ..._.__.. .__-'-..........................._-._......v _.___...____.._..................................................................m3 T i3j t I UNISEX - ! _..- --'---- 224 I u { UJ STORAGE t I ORA , STORAGE s 3 1 _ 220 ( . .._..__..._...__..._..__.._._____.__._....__.._.......... SERVER - a �- 235 } r HALL . LL 226 - --- - --_ _ I3 € ._._. - ISSUE DATE: 09.20.21 REVISIONS: .. . ... .� ......._.. .._._..___.._......_._..._....._ _.._....._. ..... .'- \ -. ..Itx�'...'".... _.... _ --ice J -_...�.._.... _. _..---- .. _._..._...__ •.� I f j KEY PLAN OFFICE OFFICE �, :, i OFFICE OFFICE OFFICE OFFICE a 237 236 227 228 229Lo 231 { Ct) N LLJ r f . , o I (D g j10CLOz cm 18" ! 18" Icl i N ._,,... 04 EE ' � ---- FLOOR PLAN - LEVEL 2 J I I J I U ui 2 I Q co 1 03 Z A2mOl LEVEL 2 g A2.o1 1/4" = 1'-0" PROJECT N• - U GENERAL NOTES �► rJ00 4 3 2 1 °° 1. ALL CEILING HEIGHTS ARE RELATIVE TO EXISTING. A 'J 2. FIELD VERIFY EXISTING CEILING LAYOUTS PRIOR TO ANY WORK. V J <� j 3. SUSPENSION SYSTEMS FOR NEW AND EXISTING SUSPENDED Lo GYPSUM BOARD CEILINGS SHALL BE MODIFIED TO FRAME AROUND CEILING INSTALLED ITEMS (n o 4 WALLS E SHOWN FOR REFERENCE.WALLS SIT JUST BELOW CEILINGS '� 5. REMOVE EXISTING CEILINGS WHERE NEW CEILINGS ARE SHOWN TO BE INSTALLED. 6. FOR TOP OF WALL DETAILS AND HEIGHT OF GYP BOARD ON WALLS, SEE PLANS,PARTITION TYPES,AND DETAILS. �/ LL1 _.. ... ... ... .... _...... _____ _..........-..........:____._..._ ... _ - . - i .....-.. r.._ ,b,� _. ,- __ _.v... . - m ....m__._ ,. ........,_.. b,.: x�w . _. .. 0 _... L� .u_. .... .,,.. «_ 7. RECESSED FIXTURES ARE TO MAINTAIN RATINGS WHERE LOCATED o - - ...__-._.._........._. ..... .._...._. __......... _ ................................. _...,.... - ._ ... ......._. _... ........ ... ...... ......_...:... . . ...__....... .. . ._...... ..._.._. . _.._..-_..-..--- _.. _ __............ IN RATED CEILING ASSEMBLIES. - --- ..... . _._----_.------...._. _.......... --- ---._._...... ---..._...._.. ._......__....__......_._...._........_..-- .__..... __..._.._...__._............ _... _..... _.. _._.._.._ _..- - -- }_:: ____.._____ .____.._. _ __.___ __.. __. .-____._ ___._ _. ._ _.___._-..____._... _....._ _............__..........._............ -_.......... -..._._..._.._......_._._._._...- '--....._.._.....__.-._.._.. ----- ......._............. ._ ...._ _ _ - i -- ....... _.._..... ._ ...__........_ .. _. _ _... __._....__.. ........_ -._._.......- - -_. ......... _...... . ..__......................................:.................. -....... - -.. ....._. ._.... ._.............._ _. _ __ I -_22211-15-64-- _..❑2.-1 —��iiIIii!1I!!I!1i iI!i —•-.11_.-2_-a__: ... iI11i, ._.;!.....- .e. '..0I..__._....._.._..._.__...._..... :.—..._.......—..._..._.. .. .__........-...._....__.. I!I! ..._ .C. *__....�.... -_�.• ..i _...,. _._.:..,. ......_._..__.._... ....._..._..-...-.._._..._ . ._..—_..._.- .._I_-❑C.❑.2...-2...__.._�_...-.._3.....1—..1.486' ..)....�. .- ...-.___..__..c._... - .._.-.._. ....-2. .. .. ..3. __1... i_ 1T 2-"- - . .._• y-' 2 . - ❑2 21-2 4— ID2 .2 ic \ _? --_---jfl ........... _- ( 4 ��S_.TfIIiII!rIti O _-_ � !!iIIiI!!II_+I! L�1;II!!!iI,!3ii _ ' .. -- / L- !V i�IVtiI - _ ! ;�iI iIIII • _ ! ;II — yii!I!)III+ — I t I!�i — E XIT ISI G N CEILING MATERIAL C1 . ..... — — .. � 1t 04 0 PROCEDURE! CRYSTAL CEILING TAG <CEILING HEIGHTIRECEPTION OFFICE 20❑3 WO AREA! U r Y EXISTING 4�_ qfl: P�_;KTELTWmo1-TBOARD CEILING ! , ; Rj0 Ei M�1 B _ I i - EXISTING WOOD CEILINGCONFERENCE 1oo OF OMRO_ 2 0 Z.o" IZI IC.141': 1. 2x4 SECOND EXISTING ACT LOOK(FALSE 2X2 TILE)HALL C N$UL9 IC.16) EXISTING 2 x 2 DROP-INI FIXTURE 4C NSUL 8CbNSULT2 — EXISTING RECESSED IC.16) DOWNLIGHT L= I I Lj I I j i EXISTING RETURN __7-11 . 7. HALL uj 208 I I PROCEDURE EXISTING SUPPLY ................ . HALL HALL BDFU ROOM' U 00M'BDF RECESSED DIRECTIONAL_ 06 _ DOWNLIGHTDR. STRAITPROCEDURE OFFICE. ! __._ . ...... PENDANT LIGHT F2......3 ti I � on _ TIES; C.5 NEW SUPPLY AIR GRILL HALL C 6 RELOCATE SPRINKLER HEAD AS REQUIRED FOR NEWET UIWALL.! C.8 NEW EXIT SIGN.SPAROOM4 C. LIHEAD REQUIRED FOR 10 DIRECTIONAL LIGHT AS LOWERED CEILING AT 8'-0A ._.. .... . Fm ........ ......... .. .. C.15 PENDANT LIGHT,TYP TBD.CENTER LIGHT OVER ADA _ a DESK(C CI)....... I C.17 RELOCATED RETURN AIR GRILL. ! D21 RELOCATE EXISTING GRILL AS SHOWN ON SHEET A3.01._ _...... ...... 9 _ . _ . . . .............. _ ........... ..... _........__. . _ MEN . .. — . . .. _ ...................... ................... ........... ......... ... ....................... ................................ .............................................. _._..... ............ - ................... _. . . . . - . . .. ... ... .._ . ..................................... _._ r. ..../7 .. .... . .._._ .... .. ....... _... .._ ....... .................. ........ . _. ....... . ._............ ......._......... _ _ . .........................._... U . ... - .-. .................... ........_...................................._.._. . .. . WOMEN .::::.:...:..._... - ...... .................. ............... _._...................._., __.._..._...................—' ................._ _ ... _ _._........._ __......_ ........:... . _ . _ ...._....... -._............_..... ...._..........._._....._..-.........._....- _........._. .__..........-_............ ..-_ Cx ;I1 f Y cn o 12 L19 BREAKROOM � ALL _........_- ! UNISEX z RAGE STORAGESERVED - NtiLcv UJU=�CoU I1 rI i tiI!!I I! , ❑2g2_, i r, ❑228- !:! - I ! C.16 __IriI . ! _- .. __....!i. _. _23 220235 ❑ ! .._..__._ _ ........_ .. .__._ _ _ .__ HALL 22g _ . __.._..... -- r !! _ r --' - ISSUE DATE: • L1. 09 20 21 ...._...... .._..._. ..._ .._ . .. . _..... .... .... ..__ . REVISIONS: CE OFFICE OFFICE bFFICEOFFICE 2❑❑229 312❑36 _---...__. _. .._...__ _ .___. .. , ! _ _ OFFICE 2KEY PLAN : W -. ... : --- - .__.._. - _ __ - - CD 04 O REFLECTED CEILING PLANLEVEL2 c t Lu A3m01 1 RCP LEVEL 2 g A3.o1 1l4" = V-0" - - PROJECT N• U - GENERAL_ NOTE_ S c, co 00 PROVIDE ADDITIONAL WALL -- - - — —-- - - - a FINISH BEHIND PTD FOR A - -- - *AT WALL-MOUNT DOME LIGHTS J 19T 1. CABINETMAKER SHALL COORDINATE WITH OTHER TRADES, c� FLUSH MOUNTING SURFACE 12" ON-ACCESSIBLE EQUIPMENT (CENTER OF BOX) VENDORS AND OWNER FOR ITEMS INSTALLED IN AND AROUND 0 N HORN/S STROBE BOTTOM OF BOX CABINETRY J C) ( ) ® ACCESSIBLE STAFF STATIONS EXTINGUISHER 2. GROMMETS AND ELECTRICAL OUTLETS: INSTALL GROMMETS IN PTD TOP OF BOX HANDLE _ COUNTERTOPS FOR ALL UNDER-COUNTER OUTLETS AS FOLLOWS: AT COUNTERTOPS ® TOP OF WALL PHONES ( ) - �/ L TYP 40"TO CONTROLS AND ® � I- - -- - AT COUNTERTOPS PULL STATION �' -- 1 1/2"DIA.GROMMET FOR UP TO 2 OUTLETS i AUTO DOOR OPENER 21/2"DIA.GROMMET FOR UP TO 4 OUTLETS - FDRONT REACISPENSER H PAND 48ENING(S E48 a � (TOP OF BOX) I I $ (CENTER OF 0PULL CORDS& )TTONS � �-' _ �, CARD READER REACH) �' g AT ALL OTHER bo 'n 3. COORDINATE MOUNTING HEIGHTS FOR ALL SIGNAGE, EQUIPMENT U - LOCATIONS(INCLUDING AND FIXTURES WITH STANDARD MOUNTING HEIGHT DRAWING. to to OPEN WORK COUNTERS) 4. PRIOR TO COVERING WALL,BACKING SHALL BE PROVIDED TO Lu % ACCOMODATE ALL HUNG ITEMS AND ACCESSORIES CALLED FOR ON i o THE CONSTRUCTION DOCUMENTS.SUCH ITEMS CONSIST OF,BUT o ELECT.OUTLETS LIGHT SWITCHES TELE/DATA CONN. Q NURSE CALL DOOR ACCESSORIES SIGNAGE _ H O PAPER TOWEL DISP. O COAT HOOK O (CENTER OF BOX) O (TOP OF BOX) O (CENTER OF BOX) FIRE ALARM DEVICES O O FIRE EXTINGUISHER CABINET O (TOP OF BOX) O (CENTER OF BOX) ARE NOT LIMITED T0: UPPERCASE CABINETS,STORAGE SHELVING, M _ TELEVISIONS,COMPUTER MONITORS,LAVATORY ACCESSORIES, li NOTES: AND FUTURE INSTALLATION OF GRAB BARS AT THE SIDES OF WATER Wo CLOSETS. _ N 1)ALL DIMENSIONS ARE TYPICAL UNLESS NOTED OTHERWISE ON INTERIOR ELEVATIONS. Q, m 2)WALL MOUNTED ACCESSORIES SHALL NOT PROJECT MORE THAN 4"FROM FACE OF WALL WHEN LOCATED BELOW 6-8". U CD D O J 3: Cc U) co 20 TYPICAL MOUNTING HEIGHTS --- - - - - — — ----- - - - - - - LEGEND u Q A5.01 1/4" = 1'-0" OFOI-OWNER FURNISHED,OWNER INSTALLED D _ OFCI-OWNER FURNISHED,CONTRACTOR INSTALLED ---_ CFCI-CONTRACTOR FURNISHED,CONTRACTOR INSTALLED K'OTT D COMBS KEYNOTES PORTL:q���, oREco�1 A.5 WALL MOUNTED MONITOR TYPICAL.VERIFY LOCATION OF 010 WITH OWNER. A.7 WALL MOUNTED MONITOR ARM,TYPICAL.VERIFY LOCATION WITH OWNER.REQUIRES BACKING. EQUIPMENT LEGEND BPM BLOOD PRESSURE MONITOR A.5 q 5 CH-S SPA CHAIR(OFCI) GLD GLOVE DISPENSER(OFCI) HK HK H/S HAND SANITIZER STATION(NEW,OFCI) BPM HK COAT HOOK GLD PTD HIS PTD LT-P PROCEDURE LIGHT(OFOI) n PTD PAPER TOWEL DISPENSER(OFCI) I Ii JI SHP SHARPS CONTAINER(OFOI) T-P ELECTRIC PROCEDURE TABLE(OFCI) g WR WASTE RECEPTACLE(OFOI) uj ._....., e e _ o x CH WR SHP SHP LT-P Lu O s PROCEDURE (215) - N 5 SPA (216) - S 4 SPA (216) - N 3 PROCEDURE 1 -213 - E 1 PROCEDURE 213 W A5.o1 3/8" = 1'-O" A5.o1 3/8" = 1'-O" A5.o1 3/8" = 1'-0" A5.o1 318" = 1'-O" A5.o1 3/8" = 1'-0" \ A.5 PTD GLD HIS A.7 PTD GLD HIS PTD GLD uj HIS _ ccs T-P -- — \ S 7HPI \ / \ / SHP WR ,' SHP \ij WR i W � Z co 1s PROCEDURE 211 S — 1s BDFU ROOM (209) W -- 11 CONSULT 214 _S $ CONSULT 214 / E - 7 PROCEDURE (215) - S CM A5.o1 3/8" - 1'-0" A5.o1 3/8" - 1'-0" A5.o1 3/8" - l'-O" A5.o1 3/8" - 1'-O" A5.o1 3/8"- 1'-O" CV - - - - - O c: 04 ti a. 0 J Q � J J � o J L LL LL GLD PTD \ HIS ._ A.5 a Ll.l o 0 0 0 h0h , {_L. SHP WR LL, 2 ENTRY (200) — E ISSUE DATE: 09.20.21 ENTRY (200) - N A5.01 3/8" - 1'-0" 19 ; PROCEDURE 211 - E 3/8" - 1'-0" �A5.o1 REVISIONS: A5.o1 _ 3/8" = 1'-0" BACKING IN WALL FOR a SIGNAGE o C/ M W/ r O / cr_ N FULL !f-O u EN u L - / N wRT CLINIC CL 0 N o .... . . .. ... INTERIOR ELEVATIONS U J J U w H 2 U Ix Q Y ENTRY (200) S A5mOl A5.01 318 = 1 -O PROJECT• NO.: 1 U 4 32co) ( I ) ( ) 1 GENERAL NOTES w Uco 1. REFER TO INTERIOR FINISH SPECIFICATIONS FOR PROJECT O .__i) "7N . DESCRIPTIONS AND ADDITIONAL INFORMATION. J M 1 2. FILL ALL HOLES CRACKS AND RECESSES IN CONCRETE FLOOR WITH � NON-SHRINK GROUT FOR A SMOOTH FINISH PREPARED TO RECEIVE =% - ai t FLOOR FINISH. O co � . t 3. HEAT WELD ALL SHEET VINYL SEAMS. x m _ 4. TOP-SET RUBBER OR VINYL WALL BASE,WHERE USED,SHALL BE �__ \ / SEALED TIGHTLY TO THE FLOOR AS WELL AS TO THE WALL. i 5. GENERAL WALL PAINT IS P-1 UNLESS NOTED OTHERWISE. l� U (:§)--- ; (� i 6. SEE INTERIOR ELEVATIONS FOR WALL PROTECTION AND CHAIR RAIL u 'f I �I HEIGHT W -.-___ - ------ - 7 OR ELEVATIONS FOR TILE PATTERNS AND LOCATION OF -- -. __...._. . SEE INTERI T ACCEN S - -- T- 1�. �` - _ -r- _____ T �- -T 8. P LAM SOFFITS TO MATCH UPPER CABINET U.N.O. cc _ in" _--- --- --_-- .- .. _ -'- \ ' /., \• X T� - ! ---_-- - '�--. _ -._L. _��_ -._ _ _1--_L- ' --- --1—T __a_-: 9. REFER TO WINDOW TYPE SHEET FOR WINDOW COVERINGS _ o k .T__ ._..----T---` ----r-.-- --,--_..- ----i _ _-----._ T.___i.---...�_.._--L---____ - . __.._.------- _____»_»._ ._..._ _ __. _. - (V __- _ -T_�__.---_ ---. I :__ ._ -------�..-'---__- 10. PROVIDE BACKSPLASH MATCHING COUNTER MATERIAL WHERE _ r� _.___,-. _r -- T-----L----.---.---.-- -�_____-�:___ 1-------.__-J._-__. -___-___j__ '---------__-.-�_ - __._ --- --- OUNTERABUTS WALL (UNLESS NOTED OTHERWISE), L a' --.r--= - \ --�-- ---_..__..-_ , .. __ _... . -�- _._ - _- _ -__ ........ . -- - - - I , 11. ALL WINDOW IL (UNLESS NOTED U -a - _ T -- -; - w : I 0 SILLS TO BE SOLID SURFACE(U SSQ O _.._-'---J----__ -�_. _ .- - - - - . _ _. - - - J -15_ T - ------------ - I_ -- --------- - - -- - � c T 1 T - - --- -- --- .. --------�- 12. 6'INTEGRAL BASE TO BE INSTALLED IN ALL HOUSEKEEPING v� cv {, -- - -- ........ 5 __-__,_ f r CRYSTALS D ROOM ND TOILET ROOM NLESS _ RK AREA ....__. .... . . ,_ -------'-- _ ----- .-.__ I.. ______ - _.. __.....____ -.--. -- 04 F.4 --- =.:._t- ' - 202 OFFICE NOTED OTHEORWIDSEOL <t r2 —_ .....�.__ -'-7 J.-.____—._--�_ L__ ...... 5 _ i. • .: . T _.-' _-- -------- , - - 203 ; . _ _.T_�_ _ _ _ __ - - _._ -- PT 1 . r - _... 155 SF : . -- RES-2 __. RES-1 - -- -- -- - - _ �3E8=1 T- .. ----T -._ - __.- - - - - - - -- - ----- - -r - - h ? — A a < -T-- - d d -- - ----- - r , -_ ------ - ----- -- - - --- �� � , — -- i. g /: i = RB 1 - R 1 - '- __........_�._ ---- ----'-- a . : Y...- _ 434 SF-- - -- - .. _ ---- - _— __ - r'.7---.__ __._.. ---- — -�----;_ -'----- -- --- --- - - ...._........_ -- -RB-1 - __ 1_ ;: PT-1 ---- SCOTT DCOMBS - —_.------- — — __ —..1_—._ _...... ._-.-- ..-__. _......_—._ ---'_ --__.._—_—_ -�...._.__ ......... ........ .__ .. .._. __.._ .. ........ F �_... 3 1 --- - s x. x. - - - __._ 1 __. - - __ -- -_. ----- -- - - __ . _._ - -' - T T : X _ -'- -- -- -- — ---- - - LEGEND __ __.� — T 11 -. -- -- - ��= - - - -rt -- . - -- -J------'---- PORTLAND, OREGON r=' --T __._ 1_.__..,.. .. _...___.. .. _.._.... —_ _ — _ .. _. _ 1. T— T O --- _ - Z T - - _- __ _ ----'T---_� _ _ _- FLOOR FINISH I L T a '—'77 _ I ..I......_� J.._. __L..._...._..__—.- ..__._— —_. _....._—.—.;--__T_ _. __. _ ��� P 2 ol �. --- Q ---- P2 F�_- , i � _-_ -,- - -T -Z_......_ is `� ACCENT WALL FINISH— _ 0 , / ! -- , _ . ' -. - __ : _ ro - T_ �_�-_ _ - _ - T- -- - ROOM FI AG — r T _ T ; R: , I T - -- _ _ _ -._ - FLOOR MATERIAL y, -_-= ._..._ �- i.S \ ---- WALL BASE - -�____d_____7- T- �- T .___ .___. —L_.—.:.................T...._..._i—_...__...._..... ----- ....- -- _.... - — _ - -- --- ------- -- ------- - S [ Z493SF F.1 - - ----- - ' -_-❑-r-- CONFERENCE aw ,a , _ ---�. _ 4 �� \ , ` d. _ __..- ROOM w RB ✓ , ........ -. ----=- -- u -.- ___ :4 -� 11.111,_" _�: -__� - --z-- - F.3 i 204 AWP 1 CR / ! -- -- -- - - T - r L�.- - - 1_ 135 SF CHAIR RAIL -: - - _ L_ -- —.. _ _ E _ - - — ,-_ --- --- .......... -- _-r -- --�-� ; --T X! \ F,6 —r �- WALL PAINT COLOR - _ F.3 T _. _ - WALL PROTECTION ( ) - -- - -------- ----_---- - - - ---- - 1 T - -- ----- y - ! \ - --' , , T r 1' r_— .— — __.._. , _ �_ 1— _ _ ES_2 _ -- - _ ___ _. _ - -- __- .._ _-__ _ I \. _ _ __ - .- - -- - - - 3- x - . - - - - r , I - F.3 ..__ T--- -- - F3 , ! RB 1 ----HAL r L -- - -y - -t—-- r -_ ?; ---- --1----- - - - - - -- - --- -- - --. ------ -- -- - -- -- _ --- - -- y \ /, �- / _ - ----- ------- T DR. STRAIT �na1 -Q- 2— i F3 T OFFICE KEYNOTES Lu — _ - -- -- - ---- --. T -----! —T- ' - - 205 „ ._ : 143 SF F 1 WALL COVERING,LEVEL 5 FINIS (PRICE AS ALTERNATE). ___ G,L H P E . PROCEDURE ;f: TS il �', i - _......... F.3 PT 4,DOOR FRAMES, CAN ✓ • , / y! _ L \ ':! •.• \ / /Y / i .. _ __—_ it _ 0 %, n F.4 PLAM-1,COUNTERS,TYPICAL. ' - ' ' wm - LLLL" F 5 PLAM ECEPTION COUNTER r F 3- 2 R ! /, 'C /, / X - - - -._ _.....-----_ . _ n $ -4 C x: \ - - PT-1 r' `' 1 --- _- -- _- /. , • --- -- . F.4 F.4 F.4 �.. i .r,. / „ T r , n S - .. - . .. .__..... t a- � - - , a a. . \ . RB-1 RB-1 RB 1 - - ! I __.__ __ F.3 I 1, RES-1 LUXURY VINYL TIL +� - r ; _ / . 12" 1 11 F.4 - PT-1 PT-2 PT 2 - - __ ' x - __ .... � --'-- -.._........--- .. QUIET RES-2 - LUXURY VINYL TILE 411 X 4 11 �,� � '�'x .. ' v ;.. - - Q S8 SPA ROOM 4 ,,� " I 11I——-r. .:_- ...:. �, 1. ROOM - - L FLOORING RES-1 SHEET VINYL .._...:__ _.._. T.__. _ ........ ..-. ___.._—_— —._ ... ..._............ _____.. ...................T._____.—_t___-- _. .._ ___ _. .._ RB-1 - RUBBER BASE -_.. ,_. - , _....i_ .. .. . .. __ ___-._ _ -.. .._._ : r !- - ' --- - - 206 - ._ _ �- -_ - - -- - - - --- - - PL 1 FORMICA COUNTERS . ' '-- r - - - T T!_-_._ 110 SF C 0U S -�_ _..- - - - - ---- --- '--- -- -' - — -- -- ; __ -- _ - - - - _ L - T FACE _ - - \ -- -- -�---- ._.. _ -- — — -— -- F. _. C .. :, t,,-Y - —'-i — ... _.____ -L —._—'..__..._.:l _- ._....1_- ..—.._ r._.- _ ----'--._—_L_.__ J. _—._ v .: __ ...______._.—_ --'— - _ ---- �j— ?'-'• _ ---. - -- ---' " -' - --- .....- _._ _.. ----- ---- - -- _ -- :. --- - . -- -:.-_ .I_. __ _ - - I PT-1 - GENERAL PAIINTE -- fm F. -_, F.3r.. -- -- -; . \ z - F.3 -- -- ! -2 -ACCENT PAINT, EXAM ROOMS _--- PT - \_ Lu J --� ___.__ _ r._.__-_ - -_. -_ - __ __- __ _ _ - PT-3 -ACCENT PAINT ENTRY WALL - -r L . _- - -- - - ____ -- __ - _ _ F ---- - r ,, -'--- '- .. -.. _..._ _._..__...... __. _.._-_-, - % v__ - r PT-4 - DOORS AND DOOR FRAMES _� --- --'-'------'-. 1 __ Fm \ 1i -_.- .... _. PT-5 - SOFFIT ABOVE RECEPTION DESK I;i :i - ' - I : \ z ". - : : I L I mi O� .__ ... . , --- T--- ' - ' i ± , �. .. . . T 1 1 --- _......_ .._.. _. i ! ---- ---.___...- ----- : . - -----.1._.__._._._...... r- T --..__..... T : - -' --- -',_..y -- i 1 . . � , i i i ?` . _ ! ,.T ` .. ; - - -- - - . ._._......_.._ 1i ! . ___.__ .. _ _----- _ _'r . : . - _ _ _..._ i I . . i I < * : _ - -.� - j; _ ..__._ __J_...j._.__._..___-__"_.!....................... i. MEN ___.______. : z _._ -_..._ .. .-' - -1.._............_._..._......_..._----T......._.._._.. _.. . 1 , : I!: - -- -1..._....._... 221 _- _ _..----- - - -- . _. . _��::; . I . uj . ! . .... .... ._..___.-___--__ - _ - I :......_ ........... _.__.. ...... .. : 1 ; ; . I ;lT ,,- :11 . , - - --'- ! - �.. MED SUPPLY i - ..._._. --.._ __..__._._.__._._�...._......._ ......_. : R __. _ .. _.. __ -- _____--._.._.___-_ _ _ EE ,::. ......i I � y AN -----'----- --.._.....-'-- - -' . - - - (� - -- +-� . . . - _.�. --- _ ❑ . _. T. 1 �:'..I........ I J i r- � _T-- ,�� 223 -� _:..................._.................._...:-.. . .. 233 ! . : i, -. - _...!. PT-1 CSI ( 346 s0 ! . i -- _ i �: r1. om O _- �... ....._....- -' - --- -- ES- r -LL ..1 - �- _....__ - _- _ - - - I . . .. _ TL - -y _......_ .._.-_. .._.__...__ ---- --. ........ _._..- - ?_ _.__ R _i -.__....._._._.._�....-_..,...-............... _ ... ----'-_::�_ - ---._z._ WOMENmi => - RE . . ;7, I __......_T_ ..-.... ......................._..- P 1 BREAKROOM _-_. ._.._ ,-_. -' _. _..._......._......_i_._�t>L�_...,........ _ _.. ' . _.. - V.-I... 2U _.. . 234 RB-TBD . _ - 2 21J ❑ .- . .❑ J 711 SF 327 SF O . D D co __ I ... _- ... _.. .... ._ _.. .. . 1 , __ _ ...... ❑� - 1 , . . \....'... ....... ..... LL Cfl �- .. I ; i — ......- --'-' i ; � ; _' - PT 1 - -- \ 1. i I r----L._,_._'j � RES-3 r ..- _ X 1 _._._ .... ., Z _.___ _______� I UNISE I I h- _ _ I 224 1 _.: ~ RB-1 d j �, 11 E Ll.! K __.. ! i _..__..___ , _ PT-1 I G I— ( ) ���-T-Y ! _ I I STORAGE STORAGE ,11. , 1 -'_-- _ - -'-- �._. 220; 232 ( -'°� 1 SERVER -� 1 129 SF I 106 SF 235 ❑ I _ 39 SF I . i HALL \ �l 1_ �..__ 226 �_ -::.-_-_.__�:�_.._______-._.___._.---___ 373 SF ` __ _� ISSUE DATE: 09.20.21 I ___'_'___'-_.__-.------_ I REVISIONS: :. _ .._.___.._.._._..-:.-.._.---........-__—__-_-_--_.._ __ ... ... ...__,......._ .._...._._ .._._. .._.r___._:_._ -...».._..__ —__.__... _.__.»_......_.._..._ -... _ __.-_._...._..»_....._.......__... ..._..»..__.......__.—._ - .-..__...- j —___.__...._..-_. _ _ _ _ -_ r 1� u_.._-_� t �' _- _-___....._- t_._.__J i 1 1 , I i M 'z _\ I 1 e I ! . i KEY PLAN ` ' I OFFICE OFFICE j OFFICE OFFICE OFFICE OFFICE a; 237 236 2271, 22228) 229 231 E. 7t 159 SF 132 SF 143 SF 126 SF 180 SF 142 SF W cq I N O i N i _1., co _ O li i i Lc) . Ti ._....._., ! _ ..__._1 O -. . c\jt 1 1 s�� fl' ...... fl ..._._._. _ .._..... __. __. --. __. , ..... "L ..... _. _. _. ._- __- __..._.. _.._._. ... _. _-__. ... ..._.....__.. ...__ ... __.. ..._ _._ - _....... = I ! - i : I >_ D i I 1 �—= i 11 11 (: ) 0 _.....-...�.. I f_--__] '-'--.-.----i i . i FINISH PLAN- LEVEL 2 I1 I I11 0 I 1I I Lu a I 0 I 1 12m0l 1 LEVEL 2 - FLOOR PLAN -- - Q 1:2.01 1/4" = 1'-0° - - PROJECT N• - U ID 2cp GENERAL NOTES coItT co 1. CABINETMAKER SHALL COORDINATE WITH OTHER TRADES, 1� N VENDORS AND OWNER FOR ITEMS INSTALLED IN AND AROUND V CABINETRY co 2. GROMMETS AND ELECTRICAL OUTLETS: INSTALL GROMMETS IN MOO COUNTERTOPS FOR ALL UNDER-COUNTER OUTLETS AS FOLLOWS: o 1 1/2"DIA.GROMMET FOR UP TO 2 OUTLETS i d 2 112"DIA.GROMMET FOR UP TO 4 OUTLETS PLASTIC LAMINATE COUNTERTOP SEE SCHEDULE 3. COORDINATE MOUNTING HEIGHTS FOR ALL SIGNAGE,EQUIPMENTD=N �� U AND FIXTURES WITH STANDARD MOUNTING HEIGHT DRAWING. "�' - SUBRAIL ,DECK ' 4. PRIOR TO COVERING WALL,BACKING SHALL BE PROVIDED TO LU - ACCOMODATE ALL HUNG ITEMS AND ACCESSORIES CALLED FOR ON i -' SEE DETAIL 51A5.02 THE CONSTRUCTION DOCUMENTS.SUCH ITEMS CONSIST OF, BUT o 6�- `—(2) 110 SHT WFL SCREWS. ARE NOT LIMITED TO: UPPERCASE CABINETS,STORAGE SHELVING, � OR 3/16 S iOT AKHM O 314"BLOCKING TELEVISIONS,COMPUTER MONITORS,LAVATORY ACCESSORIES, cc — "= Z AND FUTURE INSTALLATION OF GRAB BARS AT THE SIDES OF WATER U) o I 1 - FLUSH DRAWER FACE-TYP. CLOSETS. _ 04 o L m i V- 0 ALTEWTE 45 DEC 14 TAS 1 1/2" e o U Q p - will �,� (2) #10 SHEET METALDOOR OR DRAWER FACES ih --- BACK 114"MIN. w C0 DOOR jf 5 � -WHERE SHOWN V Q 04 TOE SPACE W/BASE(TO MATCH WALL) GEIEII~JG LM FINISHED FLOOR PAINT (TP" MICA) PLASTIC LAMINATE EDGE DETAIL R AL L# A 'v crnrr QMBS USE "PART"M CLIP" MR` o . GRID T—SM FOR TRAGI 1.. a Q 3„ STUD ATTACHMENT m OF Ogg' NOTE: SEE SCHEDULE FOR LOCATIONS s WALL BRACING 5 TYPICAL COUNTER EDGES 1 BC - DRAWER CABINET A5.02 1 1/2" = 1-4° A5.02 6.. = V-0° A5.02 1" _ 1'-0" ___..---------- SEE PLAN --- COUNTERTOP, SEE SCHEDULE FOR LOCATIONS AND TYPE z OUS. INSULATION 4'—O" EACH SIDE OF ui INSULATED PARTMONS.. SPENDED ACIDUST>IG CO UNG SYSTEM ETA. J BEAD FINISHED END OF Y x � NEOPRENE GASKET CABINET BELOW \\�I I COUNTER TOP Z — BLOCKING,TYP. uj OTRACK _ DO NOT " BD. TO � CHANNEL, COUNTERTOP EDGE ---- - � Q FINISHED END PANEL PREPAINT EXPMM LEGS FIAT MAX I I J _-- —J" repE vxv GYPStim BOARD ON 21" mETAL I I w O w STUDS 0 24" OX, U w � ACOUSTICAL INSULATION. _ _ _ _ _ _ TOE SPACE W/BASE RUBBER 13� (SEE FINISH SCHEDULE) CV om INUO!!S kCGUS'$10 SEAIAN'T UNDER BOTTOM ROUND CORNER17 TRACK A } BOTTOM OF GYP. 9D. AT UUATEI� _ P'ARTTPON ONLY 3"RADIUS CARPET (SEE FINISH SDiErKJLE) FRONT FACE OF CABINET �' —EXISTING KRETE SLAB FLOOR BELOW -- FINISHED FLOOR 3" z Q 10 INTERIOR PARTITION s COUNTER AT ROUND CORNER 2 BC - FINISHED END PANEL, TYPICAL A5.02 1 1/2" V-0" A5.02 1 11 = 11-0° - A5.02 1„ = 1'-0° 8" 4112" ADA COUNTERTOP, ADA COUNTERTOP, MATERIAL - id MATERIAL TBD (WOOD OR LAMINATE) TBD(WOOD OR LAMINATE) ct 2'-6" �xQ Lu + RADIUS EXPOSED I CORNER SUPPORT BRACKETO M + @ 4" MAX. 1/4"x 2" co CV STEEL BAR. FASTEN O N I TO BLOCKING W/(3) (<3 N 3/8" LAG BOLTS In Q + CLEAT- 1"x 1"x 1'-4" O ANGLE BLOCKING @ EA. BRACKET L- - O a� WALL AND FLOOR LL L L %� I FINISH PER FINISHCD 1% xi i ., Ll PLANS 31/2" I LED LIGHT STRIP INSTALLED IN RECEPTION DESK GYP WALL / / 1 W/WOOD FINISH OR GYP.WALL W/WOOD FINISH - WOOD SLATS, TBD OR WOOD SLATS. TBD METAL WALL / BASE, TYP 7_ RECEPTION DESK WALL 3 ADA COUNTERTOP AT RECEPTION A5.02 3" = 1'-0" A5.02 1 1/2" = V-0° 4" ISSUE DATE: 09.20.21 -------i----� -- '� SEE DETAIL 9/5.02 r COUNTERTOP, SEE PLAN REVISIONS: --METAL STUDS - @ 16"O.C. - RADIUS EXPOSED CORNER + -1/4"DIAMETER THRU BOLTS SUPPORT BRACKET @ 4" ' MAX. 1/4"x 2" STEEL BAR. a FASTEN TO BLOCKING W/ (3) 3/8" LAG BOLTS M N I�-' ---- -- --i G.W.B.BOTH SIDES GYP WALL \ N _ W/WOOD FINISH \ \ CLEAT- 1"x 1"x 1'-4" N — 3"x 3"x 1/4"STEEL ANGLE OR WOOD + ANGLE CD WELDED TO STEEL PLATE SLATS, TBD \ �I AT THE FLOOR - BLOCKING @ EA. GYP. WALL W/WOOD BRACKET FINISH OR WOOD SLATS,TBD o > WALL AND FLOOR FINISH PER FINISH PLANS c� -----5/8"EXPANSION BOLT a �, -- 12"x 3112"x 3/8" CASEWORK AND METAL WALL - STEEL PLATE BASE,TYP INTERIOR DETAILS /— BASE PER FINISH w SCHEDULE --- -- U Q 03 A5mO2 PONY WALL DETAIL Y s ____ -_ _ _ _ a RECEPTION DESK AT ROUNDED CORNER (5.02 - 1 1/2 — 1 -0 A5.02 1 1/2 — 1 -0PROJECT NO.. 2104'