Plans (13) BUP2020 -00214
OFFICE COP',
f RECEIVE`
SEP 2 8 2020
CITY OF TIUHHO
j
BUILDING DIVISION
I' \
,
I
OFFICE COPY
CITY OF TICARD„
' REVIE D FOR CODE COMPLIANCE
Approved )
A
OTC.•
Permit #;1
Address: 7 3-
i r Suit #•
13r. Date:
I t A P
AI
VALIDITY OF PERMIT
THE ISSUANCE OF A PERMIT
BASED ON CONSTRUCTION
\ / / i \ \� llllll I DOCUMENTS AND OTHER
i
DATA SHALL NOT PREVENT
THE CODE OFFICIAL FROM
REQUIRING THE CORRECTION
� I % OF ERRORS. OSSC 105.4
,
OFFICE COPY
s
Codes Sheet . .
City Codes and Regulations City codes and regulations
SHEET PLAN
CONSTRUCTION SHALL APPLY TO ALL UNIFORM BUILDING CODES LATEST Bldg. type 3 non sprinkled 3 story building X 01 Demo Plans
ADDITION AND ALL MODIFIED OR ADOPTED PROVISIONStenant 1300 sf A 01 Site Plan / Floor Plan
A 02 Construction Plan
Code: Occupancy Business Group B A 03 Electrical / Lighting Plan
2019 Oregon Structural Specialty Code Existing building area @ 1300 SF
2019 Oregon Electrical Specialty code New Building area @ 1300 SF
2019 Oregon Mechanical Specialty code Office Space @ 990 SF/ 1:100 Max Occ. - 10 R A N
Conference Space @ 195 SF / 1:15 Max Occ. - 13
Kitchen Break Room @ 115 SF / 1:100 Max Occ. - 2
Zone: TOTAL OCCUPANCY = 25
Scope of work: F I N H N C i FH K U U P
Plan Contact: Tenant improvement for existing financial office space; To include demo of
Shelter NW i existing non bearing interior walls, construction of new interior non bearing walls, and
4670 SW Pacific Ave., Beaverton, OR 97005 new interior floor plan . RANGE FINANCIAL GROUP
Todd Conger P 971 998 8186
todd@shelternw.com
Tenant: 7307 SW Beveland St. # 110
TODD FANKHOUSER Tigard OR 97223
todd@rangefinancialgroup.com i
P 503 482 4400 P 503 482 4400
7307 SW Beveland St. #110, Tigard, OR. 97223
RANGE FINANCIAL GROUP RANGE FINANCIAL GROUP cV
Todd FankHouser o O
7307 SW Beveland St. #110
Tigard, OR 97223 O
Construction Plans P 503 482 4400 N
Concrete stem wall
46'-6"
— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — -
I "
10'-9" 10'-9" 14'-9" 24'-1 8'-11"
-- ---------- --- ----------------------- -------------
-------- I _
d d o d d d e d e d e d d
4 .4 d d 4 d d d
9'-5"
d a .._a o , d d d
`^ C�
/ c
d d r c d d d d d d d If
44
d ;.
Removal of 9'6"tall nonbearing dividing wall I A 4 d d d d 4dd d
Typical 2x4 @ 16" o.c. with 9YP Board
/ d d o d d d d d 4 o d d d
V p p p 4 p O p p p O
d d c d d d d d o d d d d
O C e p
d d d d - d d d d d d d
Removal of 9'6"tall nonbearing dividing wall
Typical 2x4 @ 16" o.c. with gyp. Board o 0 o e e o 0 o e e e o a o 0 0 0
`d d 'I„ d d d d d d d d d d d 'd d d d d d d d d d d C d d
I
'4 d I` d d d c 4 d , d o 4 d d d d d d d d d d d d C o d d - d
4 p p 4 C C V
" o ° Structural'steet post to remain
- 4 o d l� d ,. d o d o 4 o d d d 4 4 e d o d d 4 G d d d d . d C :. d .4 , a . d o d
11 -/"
'
I
`d o d l_ d , d e , d e d , d d - d ,.A 4 d „� 4 d d d d d d 4 d v d d d d d
v o 0 0 0 0
d d I d d 4 4 4 4 4 d o d o d d d
-° C ° C ° C • p ° p ° C e C ° C _ ° O ° p •. ° e O ° p ° ° °.. ° ° ° ° C ° ° ° ° ° ° ° C
` u to o e o Q -. Q " " " - Q o -. -. Q o a Q o Q a v a " o ` u -• -• u ` a
1 IIIIIIIIIIIIII 46'-2" a*�,1iI',,a._.._.-�.!1; - -. �- _ � � < 9'-11" __ _____ ��\� ' .. - I -- =_"aoa`"`"`o`_,..`.a-.4dd4d:�"�•°!I'-�4pp�°°°p°°pppCpaooeaoaooeeooQeo "-"`"``a�a-`""_"ddd dd:•.° dd44 4 d
a d dd.° d `da4 d 4
.4
d d
a4 °°°4VppOppOpp°°cee°aeeeoo0eoooo
d
4C4pp°pC°apC°eppeoo,,aAQ°Aoo;eoPe
dCC4
Exterior Concrete stem wall 4 d d d d d d d d d d d d d d d d 4 d d d d d
1300 SF OFFICE SPACE ! ° °•
°OCO°pVC°p4V_Oo_.`
Existing finished
.concrete�f
l
oor
to remain.
EXISTING
e
mai
n.
EXISTING TENANT TO REMAIN
JUST RECONFIGURING SPACE -Walls to be removed are all non bearing w
alls.
d d d d d d d d d d d d d d d d d d d d d d d d 41 36'-4" 'd d d d d 4 d d G 4 d d d 4 d d e 4 4 d
04THER T�NANaSPACES
d d d d d d d d d d 4 d 4 d d d d d d d d demo wall structure
d d d d d d d d d d d d d d d d d d d d d d 4 d d d Existing Walls
d d d d d d d d d d d d d 4 d d d 4 4 d d d 4 4 d d
d d d d d Gd d d 4 d d d d d d d d d 4 4 d 4 d d
4 d d d d d d d d d dd d d 4 d d d 4 G d d d 4 4 d d
•
d d d d d4 d dd d d d d d a ddd dd d dd Gd d d
9'-7" 4 d d 4 d d 4 d d d 4 d d d d d d d d d d d d
4 d d d 4 d d d 4 d d d d 4 d d d
Raof tl4nonbearing dividing wall
pical 2x4 @ 1fi'o.c. with gyp. Board
dd d C dd d 4 d d d d dd d d d d d d
.
4 d d d d d d d d 4 d d d d d d 4 dd d d d c c d N
d d d d d d d d d d d d d d d d d d d d AP-- ----- -_ ------ -t a d d G 4 d Ci ,I rG d G A
4 .4
4 4
4 4
4 d d d d d d d d 4 d d d d d d d d dd d d d d d
I RANGE FINANCIAL GROUP
X Interior Demo Plan d d d d d d d d 4 d dd d d
21'-10" ° ° 7307 SW Beveland St. # 1
10
" " " "
d d d d d 4 C d d d d d d d d Tigard , OR 97223- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - d d P 503 482 4400
d d 4 , d d 4 d d d d d d d s d d d d d
RANGE FINANCIAL GROUP RANGE FINANCIAL GROUP CD FankHouser
7307 SW Beveland St. #110 ON
Tigard, OR 97223
Construction Plans P 503 482 4400
46'-6"
8'-11"
117
47 Parking Spots
KITCHEN BREAK
AREA 12`-10"
OFFICE SPACE 1:100/115 SF
1:100/990 Sr MAX OCC. 2
MAX OCC. 10
TFq oo I/ZZZ.ZZZZZ/,-/z
33'-0"
46'-6' TOTAL AREA: 1300 SQ. FT.
MAX OCC. 25
i
2 FLOOR PLAN
46'-2 CONFERENCE
I5'-7" ROOM
\ _ 1:15/195 SF
_ MAX OCC. 13
Area of Work j
LEASED SPACE: Q
1300 SQ. FT. _
04
40
7307 SW Beveland Street
S� GENERAL NOTES
ee�e/an
astree CONTRACTOR TO OBTAIN AND PAY FOR ALL PERMITS, ARRANGE FOR REQUIRED INSPRECTIONS AND SECURE
` APPROVALS FROM PROPER AUTHORITIES.
CONTRACTOR TO EXAMINE SITE, VERIFY DIMENSIONS AND LOCATIONS AGAINST DRAWINGS AND INFORM SELF OF
CONDITIONS UNDER WHICH WORK IS TO BE DONE BEFORE SUBMITTING PROPOSAL. NO ALLOWANCE WILL BE MADE
FOR EXTRA EXPENSE ON ACCOUNT OF ERROR.
T EGRESS ILLUMINATION TO BE NOT LESS THEN 1 FOOT CANDLE POWER AT WALKING SURFACE. PROVIDED WITH
BATTERY BACK-UP.
EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES. ILLUMINATION SHALL BE CONNECTED TO EMERGENCY POWER
1106.1 parking for accessibility& Table 1106.1 SUPPLY W/STORAGE BATTERIES.
NPer the table, 47 parking spaces requires a total of 2
accessible parking spaces, with 1 identified as van EXIT TRAVEL DISTANCE NOT TO EXCEED 75 FT.
accessible. 21'-10"
1 EXITS PROVIDED. DOUBLE-DOOR 72" FRONT ENTRANCE/EXIT PROVIDED.
MINIMUM AISLE WIDTH TO BE 42" FOR LEVEL AISLE HAVING SEATING ON BOTH SIDES
1 SITE PLAN
Al
RANGE FINANCIAL GROUP RANGE FINANCIAL GROUP
Todd FankHouser N Won
7307 SW Beveland St. #110 N O
Tigard, OR 97223 Q
Construction Plans P 503 482 4400
GENERALNOTES46'-6„
15'-4"
MAIN EXTERIOR DOOR TO BE EQUIPPED WITH KEY OPERATED LOCKING DEVICE FROM EGRESS SIDE. LOCKING DEVICE Q AD XA HANDLE
NON LOCKING
GLASS DOOR WITH 24" PULL
IS DISTINGUISHABLE AS LOCKED (EXISTING) AD
- POST SIGN "THIS DOOR TO REMAIN UNLOCKED WHIEN BUILDING IS OCCUPIED" LETTERS TO BE 1" HIGH WITH
CONTRASTING BACKGROUND. Q 2X 3'-0" X 92" 3/8"GLASS SLIDING DOORS "
WITH 24" PULL ADA HANDLES NON LOCKING !
- EXIT TRAVEL DISTANCE NOT TO EXCEED 200 FT. -
- WORK AND MATERIALS SHALL BE IN FULL ACCORD WITH THE REQUIREMENTS OF THE CURRENT BUILDING CODES. THE — ' . ' . ' — ' — I 3'-0.
STANDARD MECHANICAL CODE, ELECTRICAL CODE, NATIONAL FIRE PROTECTION ASSOCIATION AND ANY APPLICABLE J
17
STATE LAWS OR REGULATIONS. NOTHING IN DRAWINGS OR SPECIFICATIONS SHALL BE CONSTRUED TO PERMIT WORK O WALL TO BE 2X4 WOOD @ 16" OC W/GYP. 6' 4 5'-10"�
NOT CONFORMING TO THESE CODES. BOARD, TEXTURE, PRIMED, PAINTED PRINTER
C4, ETS AND SHELVES
-CONTRACTOR TO OBTAIN ALL PERMITS BEFORE WORK TO BE STATED. ARRANGE FOR INSPECTIONS AND SECURE
OB WALL TO BE 2X4 WOOD @ 16 OC W/3/8"
APPROVALS FROM PROPER AUTHORITIES.
PLYWOOD ONE SIDE /5/8" GYP BOARD ONE REFRIGERATOR KITCHEN/BREAK 9'-10"
CONTRACTOR TO EXAMINE SITE, VERIFY DIMENSIONS AND LOCATIONS AGAINST DRAWINGS AND INFORM SELF OF SIDE ROOM "
CONDITIONS UNDER WHICH WORK IS TO BE DONE BEFORE SUBMITTING PROPOSAL. THE CONTRACTOR SHALL NOTIFY SPACE DIVIDERS OFFICE/ PRINTER ROOM
FOOD FACILITY PLANNING OF ANY DISCREPANCIES. NO ALLOWANCE WILL BE MADE FOR EXTRA EXPENSE ON ACCOUNT 3'-0" 13'-0"
OF ERROR.
OFFICE
- DO NOT SCALE FROM PRINTS EXISTING STRUCTURAL
17-9" SUPPORT POST
- ALL BUILDING SHELL ELEMENTS ARE EXISTING UNDER PREVIOUSLY APPROVED BUILDING PERMITS. THE EXISTING 10'-10"
BUILDING WAS DESIGNED TO CARRY THE LOADS OF EXISTING MECHANICAL EQUIPMENT, SUSPENDED CEILING, LIGHT
FIXTURES AND INSULATION.
t +- t +-
r t +
- ALL NEW INTERIOR WALLS ARE NON BEARING.
-ALL NEW INTERIOR WALLS TO BE 2X4 WOOD @ 16" OC, W/5/8" GYP BRD. TYP X FIRE RATED, TEXTURE, PRIMED AND 3'-5" HVAC ROOMr
PAINTED. 2'-2"
L
�
3'-2 - � +
DIVIDING WALL TO BE 2X4
WOOD
@ 16"OC, W/5/8 GYP. Board
Height: 9'6" 4'-4" 0„ SINK
Existing stem wall 12'-7" 9'-3^
Existing Walls A I MICROWAVE
DISHWASHER
5"
_ NEW WALL construction _ EXIT TO SHARED HALLWAY
AND UTILITIES
6'-0"�
® Exit signs/ w Emergency egress lightini �- #8 X 1-1/2" WAFERHEAD
MEDIA UNIT SCREW THRU SLOTTED HOLE
4'-0" 3/8"Glazed Glass Partitions 7'-2" EACH SIDE OF EACH STUD
--- fes— � By Cubicles.com
I CEILING PLYWOOD 1'-0"
46'-2" I CONSTRUCTION
I
i SLOTTED TOP TRACK
` I
114-x2 1/2"SDS SCREW
i @ 16"OC (24"MAX.)
I5' 7" ! 6'-0" 16'-0"
EXIT TO SHARED
BATHROOMS AND HALLWAY I 16"I JOIST
I AT 12"O.C.
5/8" GYP. BOARD t I O
DRINK STATION
KEGERATOR
DRINK COOLER
28'-0" I
CONFERENCE ROOM I I
FRAMING AT 16" O.C. ! 6'-0"�' I
W/ P 2X4 WOOD STUDS Q 8'-2" I
1 1/4" Drywall Screw typ.
v rtically screwed @ 7" O.C. L _ I b 101-111,
I � 12'-7" 2X4 WO D @ 16"OC W/ 5/8"
tt t GYP. Bo4rd/ DO NOT ATTACH GYP BOARD AT TOP TRACK
I 9,-7„
COUCH + I
OTTOMAN
I
' I
3'-5„
12'-4" - B
T-
1
3'-0" I
WALL DETAIL B
6 5 I
2x4 PRESSURE TREATED
3/8" = 1' 6'-0" 6'-0„
RECEPTION !
:
� CONCRETE SLAB 4
N
W-6"
1 CONSTRUCTION P ' 2 TYP. WALL SECTION
A2 3/8" - 1' 21'-10" A2 3/4„ = V
RANGE FINANCIAL GROUP RANGE FINANCIAL GROUP
Todd FankHouser N N
7307 SW Beveland St. #110 N O
Tigard, OR 97223 o Q
Construction Plans P 503 482 4400
ELECTRICAL B• 37'-2"
21'-10"
15'-4" PRINTER
r� Wall Receptacle, Duplex, Mounted @ 18"from
floor unless otherwise noted - __- -1I -_'
D :0 Wall Receptacle, Duplex, Dedicated _� 6'-6"
3'-10"
171
4 * Wall Receptacle, Quad j
REFRIGERATOR
Data Jack _j — -
13'-2" 8 -
8' 0" 13'-0"
4'-011
GENERAL NOTES
17'-9„
- Do not scale Drawings
-All dimensions taken from inside face of finish walls - - 16'-0"
-All case close-offs by general contractor unless Y�
otherwise specified.
i
LIGHTING SCHEDULE
1,
I
6'-0"
L Dishwasher
• Recessed Downlight Can
20W LED 12 -7"
6'-3" Mount @ 516"for Microwave
i
• Pendant Light(Concrete), -
20W LED. *Mount at 78"from floor to bottom of
pendant
TV RECEPTACLE MOUNT @ 6'HIGH
Halo Track Lighting/Black Track QUAD MOU VT @ 3'HIGH
10W LED Fixtures Mounted every 2'OC4'-3" 4'-7" 4'-3" 4'-10
i
I
I
I
i
,
_1
5'-0„
I
15'-7" I L
8'-0" J
i • 1-
'1
C
5'-0"
1
8'-3" � •
5,_0„
r r
12'-4" t 12'-6"
t
ount @ 6'High for LED lighting behind
' 3' 10' Interior signage
-_ - • •
5'4' � 5'-0"
3'1 3'-2"
V-8" MOUNT @ 36"HIGH
A l +
-----Apr------- --J
1'-8
i
9'-7"
"
1 ELECTR MOUNT @ 36-HIGH
A3 3/8" = 1'
RANGE FINANCIAL GROUP RANGE FINANCIAL GROUP
Todd FankHouser N M
7307 SW Beveland St. #110 CN
o O
Tigard, OR 97223 Q
Construction Plans P 503 482 4400 0�