Plans BUP2018 -00108
P'y CEIVED bassetti architects
APR 12 2018
CITY OF-FIG ARD 721 NW 9TH Ave, Suite 350
BUILDING
DIVISION Portland, Oregon 97209
T (206) 340 9500 F (206) 340 9519
CIVIL ENGINEER & LANDSCAPE
Cardno
6720 SW Macadam Ave Suite 200,
Portland, OR 97219
T(503)-419-2500
STRUCTURAL ENGINEER
Catena Engineers
1500 NE Irving St., Suite 412
Portland, OR 97232
T(503)-467-4980
MECHANICAL ELECTRICAL &
PLUMBING ENGINEER
Glumac
900 SW Fifth Ave., Suite 1600
Portland, OR 97204
TENANT IMPROVEMENTS FOR MDF ROOM RELOCATION T(503)-227-5280
FOOD SERVICE CONSULTANT
Webb Foodservice Design
3700 SE Lafayette Ct.
Portland, OR 97202
T(503)-236-8566
ACOUSTIC & AV CONSULTANT
The Greenbusch Group
1900 W. Nickerson St., Suite 201
Seattle,WA 98119
T 206-378-0569
COST CONSULTANT
Construction Focus
740 Almaden St.
Eugene, OR 97402
T 541-686-2031
L.J.
Oz
LL 0
U,
z Q
W U
20
LLI J
W
0W
w 2i
0- 0
� 0
Z LL
Qo
z
w
--� #
REVISIONS DATE
u ---
i� - -
ILL TIGARD TUALATIN SCHOOL DISTRICT
i
:EJLLL�
a
TIGARD HIGH
Li
SCHOOL
zMODERNIZATION
Q
U 9000 SW DURHAM RD.
O TIGARD, OR. 97224
—� JOB NO: 16992.00
OFFICE COPY WWN ISSUE DATE: APRIL 12, 2018
CITY OF TIGARD CC
REVIEWED FOR CODE COMPUANCE G
Approve& / 0 � j
OTC: E v i _ O C� LO UNE 5fcCONACHi
ease _ 91
Addresst Lia c-� LL SEA E,wA
Suite#:
fly:
ampooft wow
0 /2718
COVER SHEET
V J
co
lf')
co
75O
N
CITY OF TIGARD MDF-GO - 00
O
approved b Planning
Date: — 4717- 1100
initials:
ABBREVIATIONS VICINITY MAP
bassetti
architects
LIST OF ARCHITECTURAL ABBREVIATIONS
ACC AMBULATORY ACCESSIBLE TOILET COMPARTMENT MAX MAXIMUM SW SETT�ST
ACP ACOUSTICAL CEILING PANEL MDF MEDIUM DENSITY FIBERBOARD
721 NW 9TH Ave, Suite 350
ACT ACOUSTICAL CEILING TILE MDO MEDIUM DENSITY OVERLAY
AFF ABOVE FINISH FLOOR MFR MANUFACTURER o Portland, Oregon 97209
ALUM ALUMINUM MIR MIRROR m J
T (206) 340 9500 F (206) 340 9519
APPROX APPROXIMATE MISC MISCELLANEOUS w 1 m
AVE AVENUE MMA METHYL METHACRYLATE
AVG AVERAGE MO MASONRY OPENING Q p S�
AWP ACOUSTICAL STRETCHED FABRIC WALL PANEL MET METAL -00 0 o�� >
BCT BABY CHANGING TABLE SURFACE MOUNTED NA NOT APPLICABLECIVIL ENGINEER & LANDSCAPE
BLDG BUILDING NIC NOT IN CONTRACT 9L =
U) F PROJECT SITE Cardno
BOT BOTTOM NR NON RATE
°D 6720 SW Macadam Ave Suite 200,C AMERICAN STANDARD CHANNEL NTS NOT TO SCALE 3: Portland, OR 97219
CPT CARPET OC ON CENTER xK T
(503)-419-2500
CG CORNER GUARD OD OUTSIDE DIAMETER
CJ CONTROL JOINT OPNG OPENING
SW DURHAM RD �-��� STRUCTURAL ENGINEER
CL CENTER LINE OPP OPPOSITE
�`��
CMU CONCRETE MASONRY UNIT OZ OUNCE Catena Engineers
COL COLUMN P PAINT w ♦ r � ��� 1500 NE Irving St., Suite 412
CONC CONCRETE PERP PERPENDICULAR
CT CERAMIC TILE PL PLATE a a �O Portland, OR 97232
DEPT DEPARTMENT PLAM PLASTIC LAMINATE oT(503)-467-4980
00
DF DRINKING FOUNTAIN PLYWD PLYWOOD JQe�
DIA DIAMETER PNL PANEL I c,� MECHANICAL ELECTRICAL &
DIM DIMENSION PTD PAPER TOWEL DISPENSER W/WAST RECEPTACLE co PLUMBING ENGINEER
DIM PT DIMENSION POINT PSF POUNDS PER SQUARE FOOT �����J
Glumac
DN DOWN PSI POUNDS PER SQUARE INCH
DR DOOR RAF RESILIENT ATHLETIC FLOORING SW WAVERLY DR Por SW Fifth Ave., Suite 1600
Portland, OR 97204
DW DISHWASHER RCP REFLECTED CEILING PLAN
DWG DRAWING REBAR REINFORCING BAR
0 5 -227-5280
EA EACH RM ROOM
FOOD SERVICE CONSULTANT
EL ELEVATION RO ROUGH OPENING UJ
ELEC ELEC ROW RIGHT OF WAY Webb Foodservice Design
co 3700 SE Lafayette ELEV ELEVATOR SCHED SCHEDULE t.
EM ENTRANCE MAT SD SOAP DISPENSER z Portland, OR 97202
EQUIP EQUIPMENT SF SQUARE FEET p 1p T(503)-236-8566
EXIST EXISTING SSHEATHING Al
ACOUSTIC & AV CONSULTANT
EXT EXTERIOR SIMIM w
SIMILAR G� The Greenbusch Grou
FA FIRE ALARM SN SANITARY NAPKIN a c���
FD FLOOR DRAIN SPEC SPECIFICATIONS 10 P
FE FIRE EXTINGUISHER SST STAINLESS STEEL cn
1900 W. Nickerson St., Suite 201
FEC FIRE EXTINGUISHER CABINET STC SOUND TRANSMISSION CLASS Seattle,WA 98119
FIO FURNISHED AND INSTALLED BY OWNER STD STANDARD T 206-378-0569
FOF FACE OF FINISH SUSP SUSPENDED
FOIC FURNISHED BY OWNER INSTALLED BY CONTRACTOR T&G TONGUE AND GROOVE
COST CONSULTANT
FOM FACE OF MASONRY TLT TOILET
FOS FACE OF STUDS TOC TOP OF CURB/TOP OF CONCRETE Construction Focus
FRWC FIBER REINFORCED WALL COVERING TPD TOILET PAPER DISPENSER 740 Almaden St.
FSP FIXED SOUND ABSORPTIVE PANELS TSCD TOILET SEAT COVER DISPENSER Eugene, OR 97402
FTG FOOTING TWS TACKABLE WALL SURFACE T 541-686-2031
GA GAUGE TYP TYPICAL
GC GENERAL CONTRACTOR UL UNDERWRITERS LABORATORIES
GWB GYPSUM WALL BOARD UNO UNLESS NOTED OTHERWISE
GYP GYPSUM UR URINAL TENANT IMPROVEMENTS FOR
HDWD HARDWOOD VERT VERTICAL
HM HOLLOW METAL VOL VOLUME
HORIZ HORIZONTAL WAC WHEEL CHAIR ACCESSIBLE TOILET COMPARTMENT
ID INSIDE DIAMETER W/O WITHOUT
IN INCHES WAF WOOD ATHLETIC FLOORING
INT INTERIOR WC-MB WALL COVERING MARKERBOARD
JT JOINT WD WOOD
L LENGTH/ANGLE(AS STRUCTURAL SHAPE) WDW WINDOW MDF ROOM RELOCATION
LB POUND WT WEIGHT
LF LINEAR FOOT
LINO LINOLEUM
LSD LIQUID SOAP DISPENSER
LWD LINEAL WOOD CEILING
GRAPHIC SYMBOLS PROJECT DATA GENERAL NOTES SHEET INDEX
PROJECT ADDRESS: TIGARD HIGH SCHOOL MDF-G0.00 COVER SHEET
9000 SW DURHAM RD. 1. VERIFY AND COORDINATE SITE CONDITIONS, EXISTING BUILDING CONDITIONS, AND DIMENSIONS.
BUILDING ELEVATION ROOM NAME TIGARD, OR. 97224 BRING INCONSISTENCIES TO ATTENTION OF ARCHITECT BEFORE PROCEEDING WITH WORK. MDF-G0.01 PROJECT INFORMATION&SHEET INDEX
Elevation ID ROOM NAME OWNER TIGARD-TUALATIN SCHOOL DISTRICT 2. IMMEDIATELY BRING INCONSISTENCIES, ERRORS AND OMISSIONS FOUND IN THE DRAWINGS AND
1 1219 6960 S.W. SANDBURG ST
SPECIFICATIONS TO ATTENTION OF ARCHITECT. MDF-A0.01 MDF PLANS
A101 Room Number TIGARD, OR 97223
Sheet Number CONTACT: CATHY KRAUS(503)913 3777 3. DO NOT SCALE DRAWINGS. COORDINATE DIMENSIONS SHOWN ON DRAWINGS WITH ACTUAL MDF-A0.02 MDF DETAILS AND SCHEDULES
FIELD MEASUREMENTS. NOTIFY ARCHITECT OF DISCREPANCIES.
ARCHITECT OF RECORD BASSETTI ARCHITECTS
721 NW 9TH AVE.,#350 4.ALL DIMENSIONS ARE TO FACE OF STUD, FACE OF CONCRETE AND NOMINAL FACE OF MASONRY,
BUILDING SECTION SCHEDULE INDICATOR PORTLAND, OR 97209 AND CENTERLINE OF COLUMNS, UNLESS NOTED OTHERWISE.
L -Louver CONTACT: CAROLINE LEMAY(503)224 9162
Section ID W_1 SF-Storefront 5. WORK INSTALLED IN CONFLICT WITH CONSTRUCTION DOCUMENTS WILL BE CONSIDERED IN
2 W-Window TAX PARCEL NO: 2S114AA00100 NON-CONFORMANCE AND SHALL BE CORRECTED AT NO EXPENSE TO OWNER OR ARCHITECT.
A3.21 FP-Fiberglass Sandwich Panel
Sheet Number SITE AREA: 43.2 Acres 6. COORDINATION: COORDINATE WORK TO COMPLY WITH DRAWINGS AND SPECIFICATIONS,
INCLUDING MECHANICAL, ELECTRICAL, EQUIPMENT AND OTHER CONSTRUCTION.
P2 RESTORATION KEY NOTE LEGAL DESCRIPTION: SECTION 11, TOWNSHIP 2 SOUTH, RANGE 1 WEST,WILLAMETTE MERIDIAN
WALL SECTION 7. FOLLOW MANUFACTURER'S INSTRUCTIONS, EXCEPT WHERE MORE STRINGENT REQUIREMENTS
ARE INDICATED OR REQUIRED BY CONSTRUCTION DOCUMENTS OR APPLICABLE CODES,
ORDINANCES AND REGULATIONS.
Section ID MATCH LINE
1 _ _ 8. PROVIDE AND INSTALL SOLID BLOCKING OR BACKING FOR ALL WALL AND CEILING MOUNTED
A4.11 ITEMS.
Sheet Number Location of Adjacent Drawing
JURISDICTION: CITY OF TIGARD 9. PROVIDE INTERMEDIATE ROD AND SHELF SUPPORTS FOR SPANS EXCEEDING 36".
FIRE DISTRICT: TUALATIN VALLEY FIRE&RESCUE # REVISIONS DATE
DETAIL REFERENCE SEWER DISTRICT: TIGARD SEWER 10. INSTALL OUTLETS, SWITCHES AND OTHER RECESSED ITEMS AT FIRE RATED WALLS IN
WATER DISTRICT: TIGARD WATER ACCORDANCE WITH I.B.C.
Detail ID DOOR NUMBER
3 CODES: CITY OF TIGARD MUNICIPAL CODE 11. INSTALL GYPSUM BOARD, OR OTHER SHEATHING OR BACKER BOARD AS SCHEDULED OR N
A9.04 2014 OREGON STRUCTURAL SPECIALTY CODE(OSSC) INDICATED, ON BOTH SIDES OF WALL FRAMING UNINTERRUPTED FROM FLOOR TO UNDERSIDE OF
Sheet Number
2014 OREGON PLUMBING SPECIALTY CODE(ORSC) FLOOR OR ROOF DECK, UNLESS NOTED OTHERWISE. N N 1
2014 OREGON MECHANICAL SPECIALTY CODE(OMSC)
N 2014 OREGON ENERGY EFFICIENCY SPECIALTY CODE(OEESC) 12.ATTACH PIPING IN SOUND RATED WALLS WITH VIBRATION ISOLATORS. ISOLATE PIPING IN
OR 2014 OREGON ELECTRICAL SPECIALTY CODE(OESC) CONTACT WITH CONSTRUCTION.
1 2014 OREGON FIRE CODE(OFC)
A101 ICC ANSI A117.1-2009 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES 13. MOUNT ELECTRICAL WIRING DEVICES AND MECHANICAL TEMPERATURE SENSORS AT HEIGHTS
S1 El
2010 OREGON SOLAR INSTALLATION SPECIALTY CODE(OSISC) PER SPECIFICATIONS. VERIFY SWITCH, OUTLET AND OTHER DEVICE HEIGHTS TO CLEAR E2
CASEWORK, RADIATORS AND WALL MOUNTED ITEMS, INCLUDING BACK SPLASHES.
RECITE NUMBER
PROPOSED USE: EDUCATIONAL 9TH-12TH GRADE 14. ISOLATE AND OFFSET OUTLETS ONE STUD SPACE MINIMUM AT SOUND RATED WALLS TO
JR241-2 OCCUPANCY: GROUP E J PREVENT SOUND TRANSMISSION. C 2
15. COORDINATE SIZES AND LOCATIONS OF OPENINGS AND ROUGH-INS FOR MECHANICAL,
TYPE OF CONSTRUCTION: PROPOSED: TYPE II-B&TYPE V-A ELECTRICAL AND OTHER EQUIPMENT WITH RELATED SUB-CONTRACTORS,AND SHOP DRAWINGS
EXISTING TYPE II-B&TYPE V-1 HR BUILDINGS EXISTING-TO-REMAIN APPROVED BY THE ARCHITECT, BEFORE PROCEEDING WITH THE WORK.
FULLY SPRINKLERED AND FIRE ALARMS 16. VERIFY SIZES AND LOCATIONS OF MECHANICAL AND ELECTRICAL EQUIPMENT PADS, CURBS, TIGARD TUALATIN SCHOOL DISTRICT
INTERIOR ELEVATION CASEWORK INDICATOR BASES, POWER,WATER AND DRAIN INSTALLATION WITH EQUIPMENT MANUFACTURERS BEFORE
Elevation ID PROCEEDING WITH THE WORK. PROVIDE AND INSTALL SEISMIC BRACING&FASTENING IN TIGARD HIGH
1A ACCORDANCE WITH CODE REQUIREMENTS.
17. COORDINATE EXACT LOCATION OF CONDUIT, PLUMBING AND PIPING WITH ELECTRICAL AND SCHOOL
1D A101 1B MECHANICAL SUBCONTRACTORS.
Sheet Number 18. EXIT DOORS: OPERABLE FROM INSIDE BUILDING WITHOUT USE OF KEY OR SPECIAL z
1C 211H KNOWLEDGE OR EFFORT. O M O D E R N I ZAT I O N
19. EXIT SIGN LETTERS: SIX INCHES HIGH MINUMUM. CONFORM WITH APPLICABLE CODES,
20. FINISHES: IN FINISHED INTERIOR AREAS: NO EXPOSED PIPE, CONDUITS, DUCTS,VENTS, ETC. Q
GRID LINES N NORTH ARROW UNLESS NOTED OTHERWISE, CONCEAL UTILITY LINES BEHIND FINISHED CONSTRUCTION UNLESS U 9000 SW DURHAM RD.
NOTED AS EXPOSED CONSTRUCTION ON DRAWINGS OR APPROVED BY ARCHITECT. IF
AFOREMENTIONED WORK CANNOT BE CONCEALED WITHIN FINISHED CONSTRUCTION OF THE O TIGARD, OR. 97224
/q CONTRACT DOCUMENTS THE CONTRACTOR SHALL PROVIDE& INSTALL FURRED&FINISHED
HORIZONTAL&VERTICAL CHASES TO MATCH ADJACENT FINISH TO CONCEAL WORK, COORDINATE -� JOB NO: 16992.00
WITH ARCHITECT. W
ISSUE DATE: APRIL 12, 2018
21. OFFSET AND ADJUST FRAMING TO MAKE FINISHED SURFACES FLUSH AND TRUE TO LINE.
PARTITION INDICATOR EXIT SIGN C
22. PROVIDE GALVANIC ISOLATION BETWEEN DISSIMILAR METALS. 0
23. FIRE EXTINGUISHER CABINETS, EXIT SIGNS, FIRE ALARM AND FIRE PROTECTION SYSTEM O
COMPONENTS SHALL BE LOCATED IN CONFORMANCE WITH KING COUNTY FIRE DEPARTMENT AND C'? LOR'�iE McCQi•91
331 Partition Type OTHER REGULATORY REQUIREMENTS. n/ eose gl
FLOOR BOX 24. PROVIDE AND INSTALL FIRE-RESISTIVE JOINT SYSTEMS, FIRE BLOCKS, DRAFT STOPS,AND t -i-3S]EEA
FIRESTOP SYSTEMS IN ACCORDANCE WITH I.B.C. A
METAL
0 0
SHELVING 25. FIRE PROTECTION: PROVIDE AUTOMATIC FIRE SUPPRESSION SPRINKLER SYSTEM
THROUGHOUT, IN ACCORDANCE WITH APPLICABLE CODES, REGULATIONS,AND ORDINANCES. ,04/1 V/zu 18
26. SPRINKLER SYSTEM TO BE APPROVED BY CITY OF TIGARD FIRE DEPARTMENT AND OTHER
REGULATORY AGENCIES PRIOR TO INSTALLATION. OBTAIN ARCHITECT'S APPROVAL OF FIRE PROJECT
PROTECTION DRAWINGS PRIOR TO SUBMITTAL FOR FIRE DEPARTMENT REVIEW.
2 27. RUN FIRE PROTECTION MAIN LINES AND INSPECTOR TEST LINES OUT BEYOND BUILDING LINES. INFORMATION
a DO NOT DRAIN WATER ACROSS SIDEWALK OR OTHER CONCRETE SURFACES. w
N �^
M 28. PROVIDE DESIGN BUILD FIRE PROTECTION DRAWINGS AND ENGINEERING AS REQUIRED BY v,
CONSTRUCTION DOCUMENTS AND CITY OF TIGARD FIRE DEPARTMENT.
Lb
ao 29. COORDINATE INSTALLATION OF FIRE PROTECTION SYSTEM WITH ARCHITECTURAL, C
V_ STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL AND OTHER WORK TO ENSURE NO CONFLICT G
oAS A RESULT OF FIRE PROTECTION SYSTEM INSTALLATION. MDF-GO . 01
30. CORNER GUARDS ARE SHOWN ON FINISH PLANS, A-10 SERIES. W
31. ELECTRICAL PERMIT AND INSPECTION MUST BE OBTAINED THROUGH OREGON STATE.
WALL LEGEND - MDF ROOM
b8ssetfi
architects
_-� EXISTING WALL (THICKNESS VARIES)
721 NW 9TH Ave, Suite 350
PROPOSED WALL (THICKNESS PER WALL TYPE) Portland, Oregon 97209
T (206) 340 9500 F (206) 340 9519
CIVIL ENGINEER & LANDSCAPE
Cardno
6720 SW Macadam Ave Suite 200,
Portland, OR 97219
T(503)-419-2500
STRUCTURAL ENGINEER
Catena Engineers
S14) S14) 1500 NE Irving St., Suite 412
Portland, OR 97232
T(503)-467-4980
MECHANICAL ELECTRICAL &
PLUMBING ENGINEER
Glumac
- 900 SW Fifth Ave., Suite 1600
CN Portland, OR 97204
T(503)-227-5280
FOOD SERVICE CONSULTANT
Webb Foodservice Design
3700 SE Lafayette Ct.
-- Portland, OR 97202
N T(503)-236-8566
1 ACOUSTIC &AV CONSULTANT
F-A0. 2 El 16-1 t The Greenbusch Group
NO CEILING 1900 W. Nickerson St., Suite 201
Seattle,WA 98119
MDF T 206-378-0569
COST CONSULTANT
Pao Construction Focus
- - , 740 Almaden St.
Eugene, OR 97402
EXISTING MAIN _ T 541-686-2031
ENTRY TO REMAIN
C O
__ _ ; • -•, •". : : L.L..
EXISTING --
ACCESSIBLE RE116-1
PATH OF - LL z
v TRAVEL TO P40
REMAIN O
V)
T. PREP °
33 _
0 23 0 0 : o 0 0 0 - ,•
w U
OFFI E I NF o KITCHEN ° 0 o PR C11 R OM LOCATION OF O
° 2q ° � 118- F• EXISTING _ _
II
A OFFI OFFICE SRO FFICE DES N ANST2102A RECEPTION FOR
3 4 PR CT.R OM ACCESS TO
WN D56 I�
COOK � Eg 116 CHOIR TELEPHONE
2c MAIN GYM II COMMONS SERI[ NURS 102 U102 OR '... O
1 I� 16c 66
•
OF C CT. 0
f1/
L1�
(� ° S 114 RO E ST R
I$�REP BA DOFF E
7 ST32 108A O � O
HEALTH -� •. tTfl ACT I I MUSIC COMM LOCATION OF �/
OFFICE D58 9 FFIC S ORAGE/M ST21 NEW DATA LL.
D60 STORE OFFICE K R OFFICE RECEP 10 LIBRARY DEMARK&
T MST R. GIRLS TEA 2 21 18 1 14 11- 106 EXISTING-TO- z LL
520 J�L2ST GUITAR
ESTING CEN R PAS �� CEPTIONI 100 REMAIN
TOR. 19c1 RM E EN EMBLE RO M ELECTRIC MAINS Q C)
GIRLS TEAM 1 19 • SPEC.ED.CR
FFICE ASS IASON PRINCIPAL - SPEC.ED.CR 120 104 � SUPPLY Z
M ST R. 514 E STOR. CONF.
512 AUL B AIL 17 15 13 • 122 N I N
20J�-a a 12 - ° •� ° MDF ROOM PLAN MDF ROOM - REFLECTED CEILING PLAN E-
�P 1 E HO CES ° ° ° ° �i
511 = CORR �
$P 506 014K �� i_L_ - =S-S=S-S-I-LZZ�=S=S-S=S=L-LZZ�-S-S� 1/4" = 1'-0" l4" - 1'-0" ----- -
508 i ��� — ° CORRIDOR 1
�711
GIRLS PE 0505T ERR OM B ROOM M FF4 VARSITY CHEE U 8.OFF. BUSINESS LA OH6
SKET OR. STOR. ( i� SOCIAL STUDIES
507 503 604A 504 MEN WOME STOR. 404 � 220 MATH ENGLISH I
04 416 414 40 ` 406 ° �I� ° 218
DAT i i• 216 ENGLISH
JAN WKRM 214
4A4D OFFICE p �i• -- PROPOSED
40oC ENGLISH ROUTE FOR
BOILER BOILER CAD 1 COMP.SCI. BUSINESS OFFIC OUNSE G �• 222 ELECTRIC AND
4A4E 418 LAB CLASSROOM SOCIAL STUDIES a ° DATA CONDUITS
422 408 404 F ti• COMMON TO MDF ROOM
�j OOC ENGLISH
OFFICE ° �i• ° 212
REFER TO HAZARDOUS
NF.
i ENGLISH REFER TO HAZARDOUS MATERIALS ABATEMENT
OOG i�i� 224 MATERIALS ABATEMENT I
OFFIC FFIC FI i -- I SPECIFICATION BY TRC DATED
JOURNALISM VIDEO OB 400H - I: ° i- SPECIFICATION BY TRC DATED
JANUARY 18 2018 AND
11111111 PRODCTION COMP.GRAPHIC V i CHE LOCATION OF JANUARY 18, 2018 AND
HAZARDOUS MATERIALS
424 4Y6 440 BUS LA �� ORKRO M SOCIALS ISH EXISTING MENS HAZARDOUS MATERIALS G �y WMN MEN ENGLISH 200 210 SURVEY REPORT BY TRC
ggoA ACCOUN CAREER CENTER ° �i� ° 1 238 I 236 2� ----�26 AND WOMENS SURVEY REPORT BY TRC DATED NOVEMBER 17,2017
446 RESTROOMS DATED NOVEMBER 17, 2017
STUDIO I 7U 446A M 450 ° ° �,• TF" �, &DRINKING / I REVISIONS DATE
4 4 �� �, ,
- - - CORRIDOf�--�" CORRIDOR WATER
-- CORR OH3 OH5 FOUNTAIN m ,�
4A4S
o ��_� SJ E V.RO M
�' 23B KIT EN I �
MATH MATH MATH MATH - TEXT STOR. FICE 206 DILE
436 438 442 444 1324 WORK R 202D _
SEE LOWER FLOOR CN — — — _ 0 -� — _ _, _ ,._ .._ - - � O CN
PLANS - ART COMPUTER LAB 232 SHWR LIFE SKILLS
_....
FE'
2A
434 ° ° COMPUTER LAB CIRCULATION 2026 0 T 202
-- ENGLISH 242 200A r� • ., -- - -
244
REMOVE FLOOR REMOVE ALL + _
CONE.RM. F'ON FINISHIN THIS AREALIGHTING AND2 LIBRARY CEILING FIXTURES IN
200E F-Ao. 1 2466 ° DEMOLISHED
OFFICE WORK RM CEILINGS
246C 246 t . . ,� n ?\
LOCATION OF _ ��\�K x r�wX� -
PROPOSED MDF OFFICE J
ROOM 246D ;
ELEC � M - • .
— OFFICE aooz °STAIR � - ' TIGARD TUALATIN SCHOOL DISTRICT
.`
246 ' - TIGARD HIGH
OFFICE
246EX ,/
! V
I x
a r ` x
ELEVATOR MECH. �j , � ��� SCHOOL
248B 248A �'` x'
STORAGE
z MODERNIZATION
LOWER LEVEL 248C OWER&UPPER LEVELS
_ Q
U
.• - 9000 SW DURHAM RD.
- TIGARD, OR.97224
REMOVE ACT AND GRID O
• i I
JOB NO: 16992.00
Uj
3 ISSUE DATE: APRIL 12, 2018
PROVIDE TEMPORARY
s BRACING FOR CEILING O � ��y
- AS NECESSARY LOPUNE NfcCONACH
❑ oD o e o
DURING
CONSTRUCTION 1 �/ ease 9t
LL
0 SEA LIE,WA
O O
104718
MDF PLANS
�S 14) IS 14)
N �' N � N �
00 OVERALL MAIN LEVEL PLAN MDF ROOM - DEMOLITION PLAN MDF ROOM - DEMO REFLECTED CEILING PLAN
N 1/32" = 1'4' 1/4" = 1'-0" - `� 1/4" = 1'-0"
w MDF-A0 . 01
WALL AND PARTITION TYPE SCHEDULE-GENERAL
NOTES: INTERIOR WALLS DOOR SCHEDULE - MDF ROOM RELOCATION T.I.
1. WALL AND PARTITION SCHEDULE FORMAT: OPENING SIZE DOOR FRAME DETAILS
WALL TYPE(A) —\ FIRE RATING(1 HR) WOOD STUD _ RATING GLAZ ELEC CARD HOLD SEC.CO KEY ELEC. PANIC COMMENTS (E) '
N0. WIDTH HEIGHT /LABEL = asse
P TYPE MATL TYPE MATL HEAD JAMB THRESH TYPE BLINDS LATCH READER OPEN NTACT SWITCH OPER HDWE EXISTING architects
A6SUBSCRIPT- E116-1 3'-0" 7'-0" F1 HM A HM
SEE BELOW
A
092116-GWB
CORE DESIGNATION(6") ONE LAYER EACH SIDE
721 NW 9TH Ave, Suite 350
PAINT Portland, Oregon 97209
T MATCH
ADJACENT SURFACES T (206) 340 9500 F (206) 340 9519
2. WALL&PARTITION TYPES ARE REFERENCED BY RELITE SCHEDULE - MDF ROOM RELOCATION
WALL&PARTITION TYPE SYMBOL.
3, WALLS&PARTITIONS ARE DIMENSIONED ON THE OPENING SIZE RATING/ FRAME DETAILS GLAZING COMMENTS (E) = CIVIL ENGINEER & LANDSCAPE
PLANS TO OTHERWISE.WA Ls&PARTITIONSNOT°WN NO. WIDTH HEIGHT LABEL ' TYPE MATL HEAD JAMB THRESH TYPE BLINDS EXISTING Cardno
DIMENSIONED ARE LOCATED BY COLUMN 6720 SW Macadam Ave Suite 200,
CENTERLINE,WINDOW MULLION OR OTHER SUCH 09 81 16-ACOUSTICAL Portland, OR 97219
OBVIOUS REGULATOR. GENERAL CONTRACTOR BLANKET INSULATION RE116-1 6'4" 4'-0" S-3 T(503)-419-2500
SHALL BE RESPONSIBLE FOR COORDINATING THE 06 10 00-WOOD FRAMING
ALL AND PARTITION LAYOUTS.
STRUCTURAL ENGINEER
4. DIFFERING WALL&PARTITION TYPES SHALL ALIGN
Catena Engineers
SO WALL PLANES CONTINUE UNBROKEN WITHIN
1500 NE Irving St., Suite 412
ROOMS AND ADJACENT FACE OF FINISHES ALIGN
Portland, OR 97232
UNLESS OTHERWISE INDICATED. T(503)-467-4980
O 2" OPNG 2" MECHANICAL ELECTRICAL &
5. TYPICAL WALL AND PARTITION FRAMING, FACING WIDTH PLUMBING ENGINEER
AND INSULATION SHALL EXTEND FULL HEIGHT TO V OPENING WIDTH WIDTH Glumac
UNDERSIDE OF FLOOR DECK OR ROOF DECK MARK STUD SIZE WALL THICKNESS = Gl SW Fifth Ave. Suite 1600
STRUCTURE ABOVE UNLESS NOTED OTHERWISE. `" Portland OR 97204
P40 3 1/2" 4 7/8" ,'I ,fl ,fl
6. PROVIDE AND INSTALL SOLID BLOCKING OR N
BACKING FOR WALL AND CEILING MOUNTED ITEMS IN
= T(503)-227-5280
ACCORDANCE WITH THE SPECIFICATIONS. EXTEND 0
BLOCKING BEYOND LOCATION INDICATED BY 16' _ FOOD SERVICE CONSULTANT
EACH SIDE. co
z = = Webb Foodservice Design
RA
o 0 3700 SE Lafayette Ct.
w z
TINGTEST/FILE VALUE
Portland, OR 97202
_
N o T(503)-236-8566
FIRE - w Uj
FLOOR LINE T.O.C. �
SOUND w FLOOR LINE T.O.C. FLOOR LINE T.O.C. ACOUSTIC &AV CONSULTANTThe Greenbusch Group
1900 W. Nickerson St., Suite 201
Seattle,WA 98119
INTERIORWALL_ TYPES - MDF_F ROOM 2 HM F1 FLUSH O T206-378-0569
_ - RELITE FRAME DOOR TYPE DOOR FRAME
COST CONSULTANT
-- 1/4" = 1'-0" - - - 1/4" = 1'-0"
- - -- onstruction Focus
740 Almaden St.
Eugene, OR 97402
T 541-686-2031
I
114000-FOOD SERVICE/MECH EQUIPMENT
L
07 62 00-PREFINISHED I r O Z
FLASHING J I 0
COPPING — —
I-
06 10 00-PLYWOOD Z U
SHEATHING,COORD W/ W
STRUCT DWGS G 0
LLJ
it
WOOD STUD BRACING 07 54 23-THERMOPLASTIC ( 0
ROOFING
HANGER
DIV 22&23-MECH HOODS II I I 0
ACP&CROSS TEE(TYP) AND FLASHINGS. COORD W/ 0
MECH AND PLUMB DWGS Ii I
(J-1
LL
06 10 00-NAILER I I Z
2X4 RUN ROOFING Q
CEILING HT OVER CURB I I Z
SEE RCP 07 54 23-THERMOPLASTIC AND SECURE I W
ROOFING 2X10 2X10 z
w
SHADOW MOLDING 2X6
GWB EACH SIDE
WOOD STUDS PER WALL
TYPE -
WALL GWB/ACP MECH EQUIP CURB EXTENSION MECH EQUIP WOOD SLEEPER
311 11-011
EXISTING ROOF REVISIONS DATE
ASSEMBLY TO
/ REMAIN
NOTES: 07 54 23-SEALANT
1. CONFIGURE FLASHINGS FOR I PROPOSED WALL
CONDUIT, PIPE, OR HSS TO BOTTOM OF
SECTIONS. I 07 62 00-PREFINISHED ROOF DECK
2. PROVIDE SINGLE PIECE ORI FLASHING
DIVIDED FLASHINGS TO SUIT
CONSTRUCTION SEQUENCE.
07 54 23-SEALANT 'Ilk
l TIGARD TUALATIN SCHOOL DISTRICT
07 62 00-SST CLAMPING
TIGARD HIGH
RING �
i
TYP.WOOD STUD 07 54 23-THERMOPLASTIC
ROOFING SCHOOL
PREMOLDED PIPE FLASHING
zMODERNIZATION
CONTINUOUS WOOD STUD EXISTING CEILING _0
BACKING AT CENTERLINE TO REMAIN.
OF ITEM TO BE ANCHORED REMOVE GRID,
Q
PROVIDE WOOD STUD BACKING LIGHTINGFIXTURES AND U 9000 SW DURHAM RD.
0
IN THE WIDTH NECESSARY TO TILES AS TIGARD, OR. 97224
NECESSARY.
ACCOMODATE ITEM TO BE i
ANCHORED OR AS NOTED. JOB N0: 16992.00
H Hill PATCH&REPAIR W
N ISSUE DATE: APRIL 12, 2018
D A4
NOTE: SOLID WOOD BLOCKING PROVIDED AT ALL TOILET HANDRAILS 0 � �
O t6PLIONRUN E'*1icCOSACH
TYP WOOD STUD BACKING DETAIL PIPE / CONDUIT PENETRATION FLASHING P40 ease, _ 9l
I..Cr_ ,
6 LL---- - - - - -- SEA Jf ,WA
0
0 /2 18
MDF —
E116 MDF DETAILS &
i
SCHEDULES
M
o I I MAIN FLOOR
- -- - -v 194'-0"
L6
00
CDr
N
75
WALL
MDF-AO. 02
SECTION - MDF ROOM
1
314"