Report (2) Oregon Residential Specialty Code R408.1
MOISTURE BARRIER ACKNOWLEDGEMENT FORM
I, , am the general contractor or the owner-builder
at the following address:
Site Address: le fi le
1 19'eA4791f41
City: '�—����� r�
Permit#: 4/7 7— 6 Zi-It:i.. 06 g 7
V ' t
Subdivision/Lot#: Uri$ f .e5
and/or
Map and Tax Lot#:
To conform with the 2017 Oregon Residential Specialty Code (ORSC), Section R408.1
Ventilation. I am notifying the building official that I have installed the Moisture Barrier as per
Requirement in ORSC Section 408.1 and have taken the following steps to meet this code
requirement:
ik:1 The ground surface of the under-floor space is covered by a Class I vapor retarder or
other approved materials, with
rizi Joints lapped 12 inches at seams and
•j.p. Extending up the foundation walls 12 inches.
Signature: Date: % Hag '��/
Ge a trac or or Owner-Builder
Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
, am the general contractor or the owner-builder
at the following address:
Site Address: I Lt i s u q Pew l
4
City: � C�
Permit#: 6 ZeY2Iv e / l r
Subdivision/Lot#: 6' t ` G
0 ri ZO
and/or
Map and Tax Lot#:
To conform with the 2017 Oregon Residential Specialty Code(ORSC), Section R318.2 and
OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement.
[Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes, the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
Signature: Date: - `/() -2Z
ne ontractor o wner-Builder
1:\Building\Form\RES-MoistureContentAcknowledgement_022018
Oregon Residential Specialty Code N1107.2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
Permit No.: r4GJ y�,�L 120 21- 05` I ? Jurisdiction: Ni t
Site Address: / sg l 51,0 to.ept7e
Subdivision/Lot#: Qaurfr,
and/or
Map and Tax Lot#:
By my signature below, I certify that all of the permanently installed lighting fixtures in the
above mentioned building contain high-efficacy lamps. Screw-in compact fluorescent and LED
lamps comply with this requirement. (Oregon Residential Specialty Code NI 107.2)1
Signature: Date: IH5--(, Z
r/General Con actor/Authorized Agent
Print Name: oCLArt
ORSC Section N 1107.2.High-efficacy lamps. All permanently installed lighting fixtures shall contain high-
efficacy lamps. Screw-in compact fluorescent and LED lamps comply with this requirement.
The building official shall be notified in writing at the final inspection that the permanently installed lighting fixtures
have met this requirement.
Exception: Two permanently installed lighting fixtures are not required to have high-efficacy lamps.
1:\Bui lding\Forms\RES-HighEfficiencyLightingAcknowledgement_022018
Blower Door Test MEM
Affidavit Moffet Energy Modeling
CCB#223372
916-342-0742
tyler@moffetco.com
Site Details
Builder Westwood Homes LLC
Subdivision Buds Landing Lot 5
Street 11841 SW Penny Ln
City/State/Zip Tigard, OR 97223
Conditioned Floor Area 2928 square feet
Conditioned Volume 27517 cubic feet
Source Plans
Test Conditions
Equipment Minneapolis Blower Door and DG 700 Manometer
Ring A
Weather Clear
Test Results
Infiltration 1724.00 CFM @ 50 Pa
ACH (CFM * 60/Volume) 3.76 @ 50 Pa
I certify that these building leakage rates are accurate and determined using standard BPI testing protocols.
Company Name: Moffet Energy Modeling
Technician: Tyler Moffet
Technician Signature: 7
4,01 Date: 4/7/2022
C.
Truk" ',PSI
local Relationships_Nauonai Resources.
USI JB Insulation
14255 SW Galbreath Drive
Sherwood, OR 97140
Installed Insulation Certificate
We certify that the insulation material listed here was installed at the address listed below:
Other than loose fill E loose fill only aluminum foil only
aluminum foil
Initial Installed&
Foam No of Coverage Minimum Settled Air Spaces Direction of
Loose Fill Kraft Unfaced Rockwool Open/Closed BIBS® R-Value Thickness Pkgs Area(SF) Thickness No.!Thickness Heat Flow
Attic e ❑ ❑ ❑ ❑ ❑ R-49
Ceilings ❑ ❑ ❑ ❑ ❑ ❑
Floors ❑ ❑ ❑ ❑ ❑ ❑
Walls ❑ 11 ❑ ❑ ❑ ❑ R-21
Basement ❑ ❑ ❑ ❑ ❑ ❑
Crawlspace ❑ ❑ 0 ❑ ❑ ❑ R-30
1 Other ❑ Cl ❑ ❑ ❑ ❑
Contractor Daniel Serene Address or Lot Number: Lot 5-11841 sw Penny Ln
(Signature)
City,ST Zip: Tigard OR 97223
Title Date Installed: 11/22/21
Tr.OPS.FRM.010
f
i