Report ' AieC2o22. -00 3 7'7
Submittal '422v u�Cs �D,
litusoFFlcE ` opy DTQP-1.0 5-24-16
DTQP
Fan Powered Terminal, Parallel Flow 14iy 18 2627
Direct Digital Control, Pressure Independent C1 i ('OF Tlt +t
B 33/8 N 20 BULLD9H '
oa i �12
00 00 0 0 61/4 00� o
u
')-- • irL ' n ,- • {
A — ilr-r li F
ir..
� p yl II I�I ail
� .JL.JL�Y�� • P
. ir—i
Primary Air Inlet
with Multipoint •
Center Averaging G 1
w
Sensor i
r_L_—Z •
-I-- •L__
I
I
I
'1--___
SI
� � Induced Air r y,," It
, G
InletIII 1
J..
1 •
11/4— E L J "
Left hand unit,top view shown. All dimensions are in inches.
Right hand units are built as a mirror image. Inlets, discharge, and control enclosure are opposite of the drawing above. a
Unit Size Inlet Size A B C D E F G H J K L w N Filter Size
6 6 5 7/8 2 7/8
O3 6 7 7/8 2'/8
10 7 97/e 4 7/8
12 8 8 9/18 16 3/4 11 /8 14 1/2 14 3 1/2 17 1/8 11 2 1/8 40'/8 36 t/8 4 /e
'/8 2 7 19 x 17
8 6 7 /8
4 10 7 9 7/8 4 7/8
12 8 11 7/8 4 7/8
14 10 137/8 6 7/8
10 7 9 7/8 4 7/8
5 12 8 11 7/8 4 7/8
14 10 137/8 67/8
16 11 101/16 241/2 157/8 17 1/2 16 1/2 91/2 20'/a 14 1/2 31/8 46 7/8 48 1/8 67/a 27 x 20
12 8 117/8 47/8
6 14 10 137/8 6'/
a
16 11 15 7/8 6'/
e
Motor Amperage Ratings Accessories (Optional)
Unit Motor 120/1/60 208/240/1/60 277/1/60 Check[f if provided.
Size hp FLA FLA FLA
Induced Air Filter, 1"thick,disposable construction type
2 '/a 3.6 1.5 *1.3
❑ Fan disconnect switch(not available on units
3 1/4 5.3 2.6 2.2 with optional electric coils.)
4 /3 7.8 3.2 2.9
5 '/3 9.2 3.3 3.2 Fibre Free Liner ❑ 1"Fiberglass Liner
6 3/4 12.3 6.3 5.4 ❑ SteriLoc Liner ❑ 1"EcoShield Liner
❑ ,A"EcoShield Liner ❑ 1"EcoShield Liner(Foil Face)
FLA= Full Load Amperage, as tested in accordance with UL 1995 ❑ %"EcoShield Liner(Foil Face) ❑ 1"Fibre Free Liner
All fan motors are single phase, same voltage as electric coil (when ❑ ,i"Fibre Free Liner --* Hanger Brackets
supplied), with exception that 277 V motors are used with 480V, 3 ❑ UltraLoc Liner
phase coils(4 wire wye). ❑ Cam Latch for Access Door
0 Fan unit fusing
DTQP-3.0 5-24-16
----IR Electric Coil Section ❑ Optional SCR Controlled Electric Heater ❑ Optional Lynergy Controlled Electric Heater
Standard Features
• Single side access to low voltage, 31
high voltage,and electric heater
controls.
• Automatic reset thermal cutouts,one o 0 0 / a o Li o
per element .
• Single point electrical connection for �-- • it TT'n� • 12
entire unit • IT T IN 1 Heater Rack
• Positive pressure flow switch ill II
iri ° Access Cover
ii
• Flanged duct connection ' • •
�_IL . . •
• Coil is installed at discharge of unit.
• Transformer
Options t
•
' I_�, 1"ryp.
y �
❑ Fuse Block r1—�___� 1 _ 1 I ll �sr
❑ Disconnect switch,door
interlock type R
❑ Manual reset cutout 1101111111
❑ Dust tight construction L_______J_' •L_J S _
❑ Mercury contactors J 1L .-
Supply Voltage a S T
208V, 1 ph,60Hz
240V, 1 ph,60Hz
❑ 277V, 1 ph,60Hz
Unit Size U R S T
❑ 208V,3 ph,60Hz
—"—fE 480V,3 ph,60Hz(4 wire wye only) 4kw, 2-step
2,3,4 3 1/2 14 11 2 1/8
5,6 9 1/2 16 1/2 14 1/2 3 1/8
R and S are inside dimensions.
General Description
• Heavy steel casing, with leak • Adjustable SCR fan speed control • Pressure independent primary
resistant construction. with minimum voltage stop. flow control.
• Dual density insulation, coated to • Bottom access panels can be • Single point electrical
prevent air erosion, meet removed for service. connections.
requirements of NFPA 90A and • Multipoint, center averaging • Rectangular discharge opening is
UL 181. velocity sensor. designed for flanged duct
• Energy efficient fan motor, • Primary air flow balancing connections.
permanent split capacitor type, connections.
mounted in vibration isolators.
This submittal is meant to demonstrate general dimensions of this product.The drawings are not meant to detail every aspect of the product.Drawings are not to scale.Titus
reserves the right to make changes without written notice.
Ad nghts reserved.No part of this work may be reproduced or transmitted in any form or by any means.electronic or mechanical,Including photocopying and recording.or by any Information storage retneval system without permission in wnting from Air Oisaibuton Technologies,Inc