Loading...
Report OFFICE COPY FPs2022.-ecO92 /Gf/2 72' RECEIVED JUN i�2022 CITY OF TIGARD .'` 31JIL-DING DIVISION , � WYATT Noi M FIRE PROTECTION, INC. 9095 S.W. Burnham Tigard, OR 97223 PACTRUST BUILDING 18 16112 SW 72ND AVE TIGARD, OR 97224 4,, �`� �+ Digitally signed ct 95730PE r Max E by Max E Colley OREGON Date: '1/4 4kCH a PI-1 C O I I e7 2022.06.08 441xcoti.k- ' 08:35:17 -07'00' EXPIRES:DECEMBER 31,2023 FIRE PROTECTION EQUIPMENT SUBMITTAL ti,cD Worldwide www.tyco-fire.com Contacts Series TY-B - 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General it is recommended that the end-user be consulted about the suitability of these • Description coatings for any given corrosive envi , 'p ronment. The effects of ambient tem The TYCO Series TY B 2.8, 5.6, perature, concentration of chemicals, and gas/chemical velocity, should bez );` and 8.0 K factor, Upright, Pendent, considered as a minimum, along with i( l' and Recessed Pendent Sprinklers described in herein are standard the corrosive nature of the chemical to !i which the sprinklers will be exposed. �., response,standard coverage,decors- * tive 5 mm glass bulb-type spray sprin- An intermediate level version of the «# klers.They are designed for use in light, Series TY-B Pendent Sprinkler can be ordinary, or extra-hazard commercial obtained by utilizing the Series TY-B occupancies such as banks, hotels, Pendent Sprinkler in combination with shopping malls, factories, refineries, the Model S2 Shield. and chemical plants. The TY-B Recessed Pendent Sprinkler, NOTICE f -�' t_ where applicable,is intended for use in The Series TY-B 2.8,5.6,and 8.0 K-fac- ' areas with a finished ceiling. It uses a tor, Upright, Pendent, and Recessed two-piece Style 10(1/2 in.NPT)or Style Pendent Sprinklers described herein 40(3/4 in.NPT)Recessed Escutcheon. must be installed and maintained in h The Recessed Escutcheon provides compliance with this document,as well 1/2 in. (12,7 mm) of recessed adjust- as with the applicable standards of the .m ment or up to 3/4 in. (19,1 mm)of total National Fire Protection Association adjustment from the flush pendent (NFPA),in addition to the standards of position. The adjustment provided by any other authorities having jurisdiction. Technical the Recessed Escutcheon reduces the Failure to do so may impair the perfor- accuracy to which the fixed pipe drops mance of these devices. Data to the sprinklers must be cut. The owner is responsible for maintain- Corrosion-resistant coatings, where ing their fire protection system and Approvals applicable, are utilized to extend devices in proper operating condi- and C , LV Listed F the life of copper alloy sprinklers tion. Contract the installing contrac- beyond LPCBdS,and NYC Approved beyond what would be obtained tor or product manufacturer with any Refer to Table A for complete approval infor- when exposed to corrosive atmo- questions, mation,including corrosion resistant status. spheres. Although corrosion-resistant NFPA 13 prohibits installation of 1/2 in. Maximum Working Pressure coated sprinklers have passed the NPT sprinklers with K-factors greater Refer to Table B standard corrosion tests of the appli than 5.6 in new construction. They are Discharge Coefficient cable approval agencies, the testing intended for retrofit in existing sprinkler K=2.8 GPM/psi' (40,3 LPM/bar") is not representative of all possible corrosive atmospheres.Consequently, systems only. K=5.6 GPM/psi' (80,6 LPM/bar' ) K=8.0 GPM/psi' (115,2 LPM/bar' ) Sprinkler Temperature Ratings IMPORTANT Refer Identification Finis to Table A Refer to Technical Data Sheet TFP2300 for warnings pertaining to Finishes f regulatory and health information. Numbers (SIN) Sprinkler:Refer to Table C Recessed Escutcheon:Signal or Pure White, Always refer to Technical Data TY1151 . . . Upright 2.8K, 1/2 in. NPT Grey Aluminum,Jet Black,Chrome Plated, Sheet TFP700 for the "INSTALLER TY1251 . . .Pendent 2.8K,1/2 in.NPT or Natural Brass WARNING" that provides cautions with respect to handling and instal TY3151 . . . Upright 5.6K, 1/2 in. NPT Physical Characteristics Bronze lation of sprinkler systems and corn- TY3251 . . .Pendent 5.6K, 1/2 in. NPT Frame Button Brass/Copper ponents. Improper handling and TY4151 . . . Upright 8.0K,3/4 in.NPT Sealing Assembly..Beryllium Nickel w/TEFLON installation can permanently damage TY4251 . . .Pendent 8.0K,3/4 in. NPT Bulb Glass a sprinkler system or its compo- TY4851 . . . Upright 8.0K, 1/2 in. NPT Compression Screw Bronze nents and cause the sprinkler to fail Bu Cooper to operate in a fire situation or cause TY4951 . . .Pendent 8.0K,1/2 in.NPT Bussector hing(K=2.8) Bronze it to operate prematurely. Page 1 of 8 JULY 2018 TFP151 TFP151 Page 2 of 8 CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw 7 3 - Sealing 6 - Deflector* jJWuI 11' =Tf tritl Assembly 7 - Bushing __ ____ __ 1 4 Bulb (11,17/1mm) ' 21/4° , 3 PI NOMINAL ____ 1 (57,2mm) � ,II _ , MAKE-IN r 2 *Temperature rating is 1-1 2-3/16" 1-9/16" 4 indicated on Deflector. (55,6 mm) (39,7 mm) \ a'�' S ** Pipe thread connections /� \` //1 =-- per ISO 7-1 can be 6* provided on special 1/2" NPT** t WRENCH request. FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 1 SERIES TY-B UPRIGHT(TY1151)AND PENDENT(TY1251)SPRINKLERS 2.8 K-FACTOR, 1/2 IN. NPT,STANDARD RESPONSE *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE W 7/16" I �r- 3 (11,1 mm) '�lei ii NOMINAL } 2 3/16" _" A. 2 - MAKE A (55,616" - 4 I i 1-. 2-3/16" 1-1/2" (55,6 mm) LIP (38,1 mm) 4. fr f��5 .-,_,�A,_-- -„�A Iiilf.- 6* 1/2"NPT** t WRENCH STYLE 10 2-7/8"(73,0 mm)DIA. - FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION ALL FINISHES EXCEPT POLY-STAINLESS WRENCH 1/2" ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated I SURFACE 4 - Bulb 6 - Deflector* on Deflector. 1 7/16" I �r 3 111 AI NOMINAL / PM 9,fy 2 _ MAKE IN i (55 6/16 mm) ilr`�- � 2 3/16" 1-1/2" ��� 4 (55,6 mm) (38,1 mm) `��5 fir- -.. 6* } STYLE 10 2-7/8"(73,0 mm)DIA. - RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION POLY-STAINLESS FINISH ONLY FIGURE 2 SERIES TY-B UPRIGHT(TY3151)AND PENDENT(TY3251)SPRINKLERS 5.6 K-FACTOR, 1/2 IN. NPT, STANDARD RESPONSE TFP151 Page 3 of 8 *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 1 1/2" 3 (12,7 mm) ' '� NOMINAL 7 2-5/16" �� 2 MAKE-IN (58,7 mm) 2-1/4" ' ffinsw 1-9/16" %�F 4 (57,2 mm) (39,7 mm) 6* 3/4" NPT** WRENCH STYLE 40 2-7/8"(73,0 mm)DIA. FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION ALL FINISHES EXCEPT POLY-STAINLESS WRENCH 3/4" ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated \,_\ SURFACE 4 - Bulb 6 - Deflector* on Deflector. airrrPrMgo t / , .... - q 1 1/2" 3 (12 7 mm) 'r '�' AA NOMINAL �� 11: _! 2 `=, MAKE-IN (58,7/m) `�_ ` �\ �`� 4 _ 2-1/4" 1-9/16" (57,2 mm) (39,7 mm) 1 j' 5 -- i • -yG 6* STYLE 40 - -2-7/8" (73,0 mm)DIA. RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION POLY-STAINLESS FINISH ONLY FIGURE 3 SERIES TY-B UPRIGHT(TY4151)AND PENDENT(TY4251)SPRINKLERS 8.0 K-FACTOR, 3/4 IN.NPT, STANDARD RESPONSE CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw 1 3 - Sealing 6 - Deflector* Assembly 3 4 - Bulb 7/16" := 2-1/4" (11,1 mm) 11 (57,2 mm) 2 NOMINAL t MAKE-IN *Temperature rating is 2-3/16" 1-9/16" indicated on Deflector. (556 mm /i11 (39,7 mm) 5 ** Pipe thread connections I 6* per ISO 7-1 can be provided on special • 1/2" NPT** t WRENCH request. FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 4 SERIES TY-B UPRIGHT(TY4851)AND PENDENT(TY4951)SPRINKLERS 8.0 K-FACTOR, 1/2 IN.NPT, STANDARD RESPONSE TFP151 Page 4 of 8 2-7/8"DIA. _ 2-7/8"DIA. 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) -(15,9±6,4 mm) 1/4"(6,4 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4"(6,4 mm) 2-1/4" DIA. FACE OF (57,2 mm) FACE OF (57,2 mm) MOUNTING MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" / (3,2 mm) / (3,2 mm) , ■ -4/7/ --- ---1 I Ell r ,/ NI ! +I } MOUNTING , MOUNTING SURFACE -;���„- SURFACE CLOSURE SERIES 1-1/4"(31,8 mm) CLOSURE SERIES 1-5/16"(33,3 mm) TY-B 3/4"(19,1 mm) N B 13/16"(20,6 mm) FIGURE 5 FIGURE 6 SERIES TY-B RECESSED PENDENT SPRINKLER SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 IN. NPT 8.0 K-FACTOR,3/4 IN.NPT WRENCH G RECESS WRENCH RECESS (END"A" USED FOR ^ 1/2"NPT MODELS) ill t if %rr WRENCH RECESS PUSH WRENCH (END"B" USED FOR IN TO ENSURE 3/4"NPT MODELS) ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 7 FIGURE 8 W-TYPE 6 W-TYPE 7 RECESSED SPRINKLER WRENCH SPRINKLER WRENCH Poly-Stainless Design Installation Physical Characteristics Frame Bronze Criteria Button L316 Stainless Steel' The TYCO Series TY-B 2.8, 5.6, and Bulb Glass 8.0 K-factor, Upright, Pendent, and Compression Screw L316 Stainless Steel* The TYCO Series TY-B 2.8, 5.6, and Recessed Pendent Sprinklers must Deflector Copper/Bronze 8.0 K-factor, Upright, Pendent, and be installed in accordance with this Sealing Assembly.Gold Plated Beryllium Nickel Recessed Pendent Sprinklers are section. • w/TEFLON protection intended for firesystems 'Type L316 stainless steel(UNS 31603)per ASTM y General Instructions A479/479M or BS EN 1008 WN1.4404. designed in accordance with the Stan- Do not install any bulb type sprinkler dard installation rules recognized by Operation the applicable Listing or Approval if the bulb is cracked or there is a loss agency, such as UL Listing based on of liquid from the bulb.With the sprin The glass bulb contains a fluid which the requirements of NFPA 13 and FM kler held horizontally,a small air bubble expands when exposed to heat.When Approval based on the requirements should be present.The diameter of the the rated temperature is reached, the of the FM Global Loss Prevention Data air bubble is approximately 1/16 in. fluid expands sufficiently to shatter the Sheets. Use only the Style 10 or 40 (•1,6 mm) for the 135 F (57 C) to glass bulb, allowing the sprinkler to Recessed Escutcheon, as applicable, 3/32 in.(2,4 mm)for the 360°F(182°C) activate and water to flow. for recessed pendent installations. temperature ratings. A leak-tight 1/2 in. NPT sprinkler joint should be obtained by apply- ing a minimum-to-maximum torque of 7 to 14 lb-ft (9,5 to 19,0 N•m). Obtain a leak-tight 3/4 in. NPT sprinkler joint by applying a minimum to maximum TFP151 Page 5 of 8 Sprinkler Temperature Bulb Sprinkler Finish8 K Liquid Wax-Over- Type Rating Color Natural Chrome Polyester Pol Stainless° Lead Wax y y Lead Brass Plated Coated Coated Coated 135°F(57°C) Orange Upright 155°F(68°C) Red (TY1151) 2.8 and 175°F(79°C) Yellow 1,2,3 1/2 in. Pendent N/A N/Ad NPT (TY1251) 200°F(93°C) Green Figure 1 286°F(141°C) Blue 360°F(182°C) Mauve 1,2 135°F(57°C) Orange Upright 155°F(68°C) Red (TY3151) 1,2,3,5 1,2,3,5 and 175°F(79°C) Yellow Pendent 200°F(93°C) Green 1,2,3,4,5,6,7 1,2 1,2,3,5 (TY3251) 5.6 Figure 2 286°F(141°C) Blue lb,2b,3b,5b lb,2b,3b,5b 1/2 in. 360°F(182°C) Mauve N/A NPT 135°F(57°C) Orange Recessed 155°F(68°C) Red Pendent 1,2,3,4,5 175°F(79°C) Yellow 1,2 N/A (TY3251)a Figure 5 200°F(93°C) Green 286°F(141°C) Blue 1,2 135°F(57°C) Orange Upright 155°F(68°C) Red (TY4151) 1,2,3,5 1,2,5 and 175°F(79°C) Yellow Pendent 200°F(93°C) Green 1,2,3,4,5,6,7 1,2 1,2,5 (TY4251) 8.0 Figure 3 286°F(141°C) Blue lb,2b,3b,5b lb,2b,5b 3/4 in. 360°F(182°C) Mauve N/A NPT 135°F(57°C) Orange Recessed 155°F(68°C) Red Pendent 1,2,3,4,5 (TY4251)a 175°F(79°C) Yellow 1,2 N/A Figure 6 200°F(93°C) Green 286°F(141°C) Blue 1,2 135°F(57°C) Orange Upright 155°F(68°C) Red (TY4851) 8.0 and 175°F(79°C) Yellow 1/2 in. Pendent (93°C) 1,2,3,4,5,6 N/A N/A NPT (TY4951) 200°F 93°C) Green Figure 4 286°F(141°C) Blue 360°F(182°C) Mauve NOTES 1. Listed by Underwriters Laboratories,Inc.(UL). 2. Listed by Underwriters Laboratories,Inc.for use in Canada(C-UL). 3. Approved by FM Global(FM Approvals). 4. Approved by the Loss Prevention Certification Board(LPCB Ref.No.007k/03). 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved.(For details,contact Johnson Controls,Enschede,Netherlands,Tel.31-53-428-4444/Fax 31-53-428-3377) 7. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/05) 8. Where Polyester Coated,Lead Coated,Wax Coated,and Wax-over-Lead Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers.Where Lead Coated,Wax Coated,and Wax-over-Lead Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as Corrosion-Resistant Sprinklers. a. Installed with Style 10(1/2 in.NPT)or Style 40(3/4 in.NPT)3/4 in.Total Adjustment Recessed Escutcheon,as applicable b. 150°F(66°C)maximum ceiling temperature c. Frame and deflector only d. Not Applicable(N/A) TABLE A SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS LABORATORY LISTINGS AND APPROVALS TFP151 Page 6 of 8 Type Sprinkler Finish K Natural Brass Chrome polyesters Lead Wax Wax-Over-Lead Plated Coated Coated Coated P.8 Upright(TY1151) 1/2 in. and 175 psi(12,1 bar) N/A3 NPT Pendent(TY1251) Upright(TY3151) and 5.6 Pendent(TY3251) 250 psi(17,2 bar)2 1/2 in. _ or NPT 175 psi(12,1 bar) Recessed Pendent (TY3251) Upright(TY4151) and 175 psi(12,1 bar) 8.0 Pendent(TY4251) 3/4 in. NPT Recessed Pendent 175 psi(12,1 bar) N/A (TY4251) 8.0 Upright(TY4851) 1/2 in. and 175 psi(12,1 bar) NPT Pendent(TY4951) NOTES 1. Frame and deflector only 2. The maximum working pressure of 250 psi(17,2 bar)only applies to the Listing by Underwriters Laboratories,Inc.(UL),the Listing by Underwriters Laboratories,Inc.for use in Canada(C-UL),and the Approval by the City of New York. 3. Not Applicable(N/A) TABLE B SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS MAXIMUM WORKING PRESSURE torque of 10 to 20 lb-ft (13,4 to Step 3. Tighten the sprinkler into the After Installation 26,8 N•m). Higher levels of torque may sprinkler fitting using only the W-Type After installation, complete the distort the sprinkler inlet and cause 6 Sprinkler Wrench (Ref. Figure 7). following: leakage or impairment of the sprinkler. For wax-coated sprinklers, use an • Inspect the sprinkler wrench flats Do not attempt to compensate for 8 or 10 in. adjustable wrench. With and frame arms and retouch(repair) insufficient adjustment in the escutch reference to Figure 1 to 4, apply the the wax coating whenever the coat- eon plate by under- or over-tightening W-Type 6 Recessed Sprinkler Wrench ing has been damaged and bare the sprinkler. Re-adjust the position of or an adjustable wrench,as applicable, metal is exposed. the sprinkler fitting to suit. to the sprinkler wrench flats. • Retouch the wax coating on the Wax Coated Sprinklers Series TY-B Upright and Pendent When installing wax coated sprinklers wrench flats by gently applying a Sprinklers Installation with an adjustable wrench,take care to heated 1/8 inch diameter steel rod The Series TY-B Upright and Pendent to the damaged areas of wax, to Sprinklers must be installed in accor- prevent damage to the wax coating on smooth it back over areas where dance with the following instructions: the sprinkler wrench flats or frame arms bare metal is exposed. and, consequently, exposure of bare Step 1.Install pendent sprinklers in the metal to the corrosive environment: NOTICE pendent position. Install upright sprin- • Open the jaws of the wrench suffi- klers in the upright position. Only retouching of the wax coating ciently wide to pass over the wrench applied to the wrench flats and frame Step 2. With pipe thread sealant flats without damaging the wax arms is permitted, and the retouching applied to the pipe threads, hand- coating. is to be performed only at the time of tighten the sprinkler into the sprinkler • Before wrench tightening the sprin- the initial sprinkler installation. fitting, kler, adjust the jaws of the wrench to to contact only the sprinkler wrench The pointteel rod cans begidn to heated only x, flats. the point it begin melt the wax, and appropriate precautions need to be • After wrench tightening the sprin- taken when handling the heated rod in kler, loosen the wrench jaws before order to prevent the installer from being removing the wrench. burned. TFP151 Page 7 of 8 Series TY-B Recessed Pendent Care and Automatic sprinklers must never be Sprinklers painted, plated, coated, or other- The Series TY-B Recessed Pendent Maintenance wise altered after leaving the factory. Sprinklers must be installed in accor- Modified sprinklers must be replaced. dance with the following instructions: The TYCO Series TY-B 2.8, 5.6, and Sprinklers that have been exposed to Step 1. After installing the Style 10 8.0 K-factor, Upright, Pendent, and corrosive products of combustion, but or 40 Mounting Plate, as applicable, Recessed Pendent Sprinklers must be have not operated,should be replaced over the sprinkler threads and with maintained and serviced in accordance if they cannot be completely cleaned pipe thread sealant applied to the pipe with this section. by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. threads,hand tighten the sprinkler into Before closing a fire protection system the sprinkler fitting. main control valve for maintenance Care must be exercised to avoid Step 2. Tighten the sprinkler into the work on the fire protection system damage to the sprinklers before, sprinkler fitting using only the W-Type that it controls, obtain permission to during, and after installation. Sprin 7 Recessed Sprinkler Wrench (Ref. shut down the affected fire protection klers damaged by dropping, striking, Figure 8).With reference to Figure 3 or system from the proper authorities wrench twist/slippage,or the like,must 4,apply the W-Type 7 Recessed Sprin- and notify all personnel who may be be replaced.Also,replace any sprinkler kler wrench to the sprinkler wrench affected by this action. that has a cracked bulb or that has lost flats. liquid from its bulb. Refer to the Instal- The owner must assure that the sprin- lation Section. Step 3.After the ceiling is installed or klers are not used for hanging any The owner is responsible for the the finish coat is applied, slide on the objects and that the sprinklers are only Style 10 or 40 Closure over the Series cleaned by means of gently dusting inspection, testing, and maintenance TY-B Recessed Pendent Sprinkler with a feather duster; otherwise, non- of their fire protection system and and push the Closure over the Mount- operation in the event of a fire or inad devices in compliance with this doc ing Plate until its flange contacts the vertent operation may result. ument, as well as with the applicable standards of the National Fire Protec- ceiling. Absence of an escutcheon, which is tion Association,(e.g., NFPA 25), in used to cover a clearance, may delay addition to the standards of any other the time to sprinkler operation in a fire authorities having jurisdiction.Contact situation. the installing contractor or product Sprinklers which are found to be manufacturer with any questions. leaking or exhibiting visible signs of Automatic sprinkler are recommended corrosion must be replaced. to be inspected,tested,and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. 1 r TFP151 Page 8 of 8 P/N 57 - XXX - X - XXX I I SPRINKLER TEMPERATURE SIN FINISH RATING 530 2.8K UPRIGHT(1/2 in.NPT) TY1151 1 NATURAL BRASS 135 135°F(57°C) 531 2.8K PENDENT(1/2 in.NPT) TY1251 POLY-STAINLESS GREY 155 155°F(68°C) 2 ALUMINUM(RAL9007)1 POLYESTER 175 175°F(79°C) 570 5.6K UPRIGHT(1/2 in.NPT) TY3151 3 PURE WHITE(RAL9010)2 POLYESTER 200 200°F(93°C) 571 5.6K PENDENT(1/2 in.NPT) TY3251 4 SIGNAL WHITE(RAL9003) POLYESTER 286 286°F(141°C) 590 8.0K UPRIGHT(3/4 in.NPT) TY4151 5 JET BLACK(RAL9005)3 591 8.0K PENDENT(3/4 in.NPT) TY4251 POLYESTER 360 360°F(182°C) 6 WAX COATED 560 8.0K UPRIGHT(1/2 in.NPT) TY4851 286°F(141°C)MAX 000 OPEN', 7 LEAD COATED 561 8.0K PENDENT(1/2 in.NPT) TY4951 8 WAX-OVER-LEAD 286°F(141°C)MAX 9 CHROME PLATED NOTES 1. Only available on TY3151,TY3251,TY4151,and TY4251. 2. Eastern Hemisphere sales only. 3. Available in only 8.0K,155°F(68°C)or 200°F(93°C);requires lead time to manufacture. 4. Available only for 8.0 K-factor TY4151 and TY4251 for use in deluge systems("OPEN"indicates sprinkler assembly without glass bulb,button,and sealing assembly). TABLE C SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Sprinkler Wrenches Specify: W-Type 6 Sprinkler Wrench, P/N 56 000 6 387 Warranty Specify: W-Type 7 Sprinkler Wrench, For warranty terms and conditions,visit P/N 56-850-4-001 www.tyco-fire.com. Wax Sticks(for retouching wrench- Ordering damaged wax coating) Specify: (specify color, below) Color- coded Wax Sticks for retouching Procedure (specify temperature rating) tempera- Contact your local distributor for avail- ture-rated Series TY-B Sprinklers,P/N ability.When placing an order,indicate (specify) the full product name and Part Number Black for 135°F(57°C) P/N 56-065-1-135 (P/N). Red for 155°F(68°C) P/N 56-065-1-155 Yellow for 175°F(79°C) P/N 56-065-1-175 Sprinkler Assemblies with Blue for 200°F(93°C) NPT Thread Connections and 286°F(141°C) P/N 56-065-1- 286 Specify: Series TY-B (specify SIN), (specify K-factor), (specify Upright Note: Each wax stick is suitable for or Pendent) Sprinkler with (specify) retouching up to 25 sprinklers. temperature rating, (specify) finish or The wax used for 286°F(141°C)sprinklers coating, P/N(Refer to Table C) is the same as for 200°F(93°C)sprinklers. Recessed Escutcheon Therefore, the 286°F (141°C) sprinkler Specify: Style (10 or 40) Recessed is limited to the same maximum ceiling Escutcheon with (specify") finish, P/N temperature as the 200°F(93°C)sprinkler (specify`) which is 150°F(66°C). Refer to Technical Data Sheet TFP770 1400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 /' 02018 Johnson Controls.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice. Johnson Inson �r,/I NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association, Controls TEFLON is a registered trademark°f DuPont oFocr COPY RECEIVED JUN $2022 CITY OF TIGARD 3UILDING DIVISION . . . W YAT T 44000, FIRE PROTECTION, INC. 9095 S.W. Burnham Tigard, OR 97223 PACTRUST BUILDING 18 16112 SW 72ND AVE TIGARD, OR 97224 6,e,o PROFFSiS' � Gt N �� /o� M ax E = s:9oIe: 9573QPE Date: OREGON Colley 2022.06.08 '�'9RCy9,p'�° 08:34:43 -07'00' Mqk cou- EXPIRES:DECEMBER 31,2023 FIRE PROTECTION HYDRAULIC CALCULATIONS '* l Hydraulic Overview Job Number 1 Report Description:Spec.Warehouse Job Job Number Design Engine, 1 Max Colley Job Name'. FAX Pac Trust Building 18 503-684-2928 Address 1 -.._-. State Cert,ficotion/kicenee Number -_-.... 16160 SW 72nd Ave Address 2 AHJ Tigard,OR 97223 Address 3 Job Site/Building System Density Area of Appllcanon 0.24gpm/ft' 2000ft'(Actual 2090ft') Most Demanding Sprinkler Data Hose Streams 8 K-Factor 29.50 at 13.598 500.00 1 Coverage Per Sprinkler Number Of Spnnlders Calculated 123ft' 17 0 system Pmaswe Demand -._----- - Syste oe Demand 88.324 546.86 Total Demand Pressure Result 1046.86 @ 88.324 +10.105(10.30/0) Supplies Check Point Gauges Node Name Flow(gpm) Hose Flow(gpm) Static(pslt Residual(psi) Identifier Pressure:psi) K-Factor(K) Flow(gpm) 108 Water Supply 2160.00 500.00 100.000 94.000 Meister.cad Water Supply at Node 108(2160.00,500.00,100.000,94.000) 150 — 135 120 5 105-E.-Static Pressure 100.000 ' 9 0 2160.00 @ 94.000 a 1046.86 with hose streams _�., 6 75 I I „sadhsb _ I m ht,Ll a 60 y a ]System demand curve tiah l 1 lI 45 -v 11-1-4(e.a6 30 15 0 IIIIIIIIIIIIIIIIIIII IIIIIIIII IIIIIIIII 111111111 111111111 111111111 111111 I I I 45o0Q3501800 2250 2700 3150 3600 4050 4500 Water flow,gpm LA,S M E P.CAD,Inc in AutoSPRINK 2020 v16.3.21.0 6/7/2022 7.55 35AM Page 1 4 Summary Of Outflowing Devices J Job Number: Report Description:Spec.Warehouse Actual Flow Minimum Flow K-Factor Pressure Device (gpm) (gpm) (K) (psi) E Sprinkler 1000 ' 29.50 29.50 8 13.598 Sprinkler 1001 29.50 29.50 8 13.600 Sprinkler 1002 30.30 _ 29.50 8 14.347 Sprinkler 1003 32.99 29.50 8 17.001 Sprinkler 1004 30.18 29.50 8 14.234 Sprinkler 1005 30.06 29.50 8 14.117 Sprinkler 1006 30.06 29.50 8 14.118 Sprinkler 1007 30.85 29.50 8 14.868 Sprinkler 1008 33.53 29.50 8 17.571 Sprinkler 1009 30.78 29.50 8 14.799 Sprinkler 1010 32.68 29.50 8 16.687 Sprinkler 1011 33.36 29.50 8 17.391 Sprinkler 1012 33.78 29.50 8 17.830 Sprinkler 1013 33.99 29.50 8 18.051 Sprinkler 1014 35.67 29.50 8 19.878 Sprinkler 1015 34.04 29.50 8 18.104 Sprinkler 1016 35.59 29.50 8 19.796 c> Most Demanding Sprinkler Data L ©M.E.P.CAD,Inc. 111 AutoSPRINK 2020 v16.3.21.0 6/7/2022 7:55:36AM Page 2 4* V Hydraulic Analysis Job Number:1 I.AIReport Description:Spec.Warehouse Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length rid Route 1 BL 1.3800 1.27 0 27 120 0.000209 9'-10 Pf 0.002 1000 21'-0 29.50 8 13.598 Sprinkler Pe 1001 21'-0 13.600 9'-10 Pv BL 1.3800 30.77 _ 6.60 120 0.075959 9'-10 Pf 0.747 1001 21'-0 29.50 8 13.600 Sprinkler Pe 1002 21'-0 14.347 9'-10 Pv BL 1.3800 61.08 13.10 120 0.269958 _ 9'-10 Pf 2.655 1002 21'-0 30.30 8 14.347 Sprinkler Pe 1003 21'-0 17.001 9'-10 Pv BL _ 1.3800 94.06 20.18 120 0.600143 57'-4 Pf 41.610 1003 21'-0 32.99 8 17.001 Sprinkler, 12'-0 Pe 0.686 100 19'-5 59.298 T(6'-0) P0(6'-0) 69'-4 Pv CM 2.6350 189.28 11.14 120 0.093773 12'-3% Pf 1.153 100 19'-5 95.21 59.298 Flow(q)from Route 3 Pe 101 19'-5 60.450 12'-3+%Pv CM _ 2.6350 274.85 16.17 120 0.186973 12'-3% Pf 2.298 101 19'-5 85.57 60.450 Flow(q)from Route 7 Pe 102 19'-5 62.748 12'-3% Pv CM 2.6350 332.27 19.55 120 0.265585 5'-1+% Pf 5.742 102 19'-5 57.42 62.748 Flow(q)from Route 2 16'-5% Pe 103 19'-5 68.490 T(16'-5%,) 21-7%Pv CM 3.2600 546.86 21.02 120 0.236784 6'-8 Pf 3 806 103 19'-5 214.59 68.490 Flow(q)from Route 10 9'-5 Pe 104 19'-5 72.296 E(9'-5) 16'-1 Pv FM 4.2600 546.86 12.31 120 0.064342 19'-5 Pf 4.249 104 19'-5 72.296 Pe 8 418 105 0'-0 84.963 PIV(-3.000) 19'-5'Pv FR 6.3570 546.86 5.53 120 0.009160 5'-0 Pf 0 207 105 0'-0 84.963 17'-7 Pe 2.168 106 -5'-0 87.338 E(17'-7) 22'-7 Pv UG 6.2800 546.86 5.66 120 0.009720 52'-7 Pf 0.672 106 -5'-0 87.338 16'-7 Pe 107 -5'-0 88.010 - E(16'-7) 69'-2 Pv UG 10.4000 546.86 2.07 140 0.000626 500'-0 Pf 0 313 107 -5'-0 88.010 Pe 108 -5'-0 88.324 Water Supply 500'-0 Pv 500.00 Hose Allowance At Source 108 1046.86 e;i. Route 2 BL 1.3800 28.23 6.06 120 0.064745 9'-10 Pf 0.637 1000 21'-0 29.50 8 13.598 Sprinkler Pe 1004 21'-0 14.234 9'-10 Pv BL 1.3800 58.41 12.53 120 0.248575 6'-11 Pf 3 210 1004 21'-0 30.18 8 14.234 Sprinkler, 6'-0 Pe 109 21'-0 17.444 T(6'-0) 12'-11 Pv RN 1.3800 91.09 19.54 120 0.565545 2'-0 Pf 4.524 109 21'-0 32.68 17.444 Flow(q)from Route 5 6'-0 Pe 0.867 110 19'-0 22.835 P0(6'-0) 8'-0 Pv CM 2.1570 184.51 16.20 120 0.237109 12'-3% Pf 2.914 110 19'-0 93.42 22.835 Flow(q)from Route 4 Pe 111 19'-0 25.750 12'-3+%Pv CM 2.1570 272.01 23.88 120 0.486162 12'-3+% Pf 5.976 111 19'-0 87.50 25.750 Flow(q)from Route 8 Pe 112 19'-0 31.726 12'-3% Pv RN 1.3800 57.42 12.32 120 0.240806 105'-7 l Pf 31 203 112 19'-0 31.726 P0(6'-0) 24'-0 Pe -0181 102 19'-5 62.748 2T(6'-0),P0(6'-0) 129'-7 iPv = Route 3 BL 1.3800 0.77 0.17 120 0.000084_ 9'-10 i Pf 0 001 1005 21'-0 30.06 8 14.117 Sprinkler I Pe 1006 21'-0 14.118 9'-10'Pv BL 1.3800 30.83 6.61 120 0.076230 9-10 1 Pf 0.750 1006 21'-0 30.06 8 14.118 Sprinkler Pe 1007 21'-0 14.868 9'-10 Pv L,©M.E.P.CAD,Inc. 1 AutoSPRINK 2020 v16.3.21.0 6/7/2022 7:55:37AM Page 3 j4ydrauhcAnaIysIs Job Number:1 . Report Description:Spec.Warehouse Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length BL 1.3800 61.68 13.23 120 0.274923 9'-10 Pf 2.703 1007 21'-0 30.85 8 14.868 Sprinkler Pe 1008 21'-0 17.571 9'-10 Pv BL 1.3800 95.21 20.42 120 0.613821 57'-4 Pf 40.717 1008 21'-0 33.53 8 17.571 Sprinkler, 9'-0 Pe 0.686 113 19'-5 58.974 T(6'-0),E(3'-0) 66'-4 Pv CM 2.6350 95.21 5.60 120 0.026306 12'-3'% Pf 0.323 113 19'-5 58.974 Pe 100 19'-5 59.298 12'-3'% Pv w Route 4 BL 1.3800 29.28 6.28 120 0.069297 9'-10 Pf 0.681 1005 21'-0 30.06 8 14.117 Sprinkler Pe 1009 21'-0 14.799 9'-10 Pv BL 1.3800 60.06 12.88 120 0.261707 6'-11 Pf 3.379 1009 21'-0 30.78 8 14.799 Sprinkler, 6'-0 Pe 114 21'-0 18.178 T(6'-0) 12'-11 Pv RN 1.3800 93.42 20.04 120 0.592608 2'-0 Pf 2.963 114 21'-0 33.36 18.178 Flow(q)from Route 6 3'-0 Pe 0.867 115 19'-0 22.008 E(3'-0) 5'-0 Pv CM 2.1570 93.42 8.20 120 0.067318 12'-3% Pf 0.827 115 19'-0 22.008 Pe 110 19'-0 22.835 12'-3'% Pv Route 5 BL 1.3800 32.68 7.01 120 0.084889 2'-11 Pf 0.757 1010 21'-0 32.68 8 16.687 Sprinkler, 6'-0 Pe 109 21'-0 17.444 T(6'-0) 8'-11 Pv GIP Route 6 BL 1.3800 33.36 7.16 120 0.088198 2'-11!Pf 0.787 1011 21'-0 33.36 8 17.391 Sprinkler, 6'-0'Pe 114 21'-0 18.178 T(6'-0) 8'-11 Pv Q Route 7 BL 1.3800 15.92 3.41 120 0.022433 9'-10 Pf 0.221 1012 21'-0 33.78 8 17.830 Sprinkler Pe 1013 21'-0 18.051 9'-10 Pv BL 1.3800 49.91 10.70 120 0.185793 9'-10 Pf 1.827 1013 21'-0 33.99 8 18.051 Sprinkler Pe 1014 21'-0 19.878 9'-10 Pv BL 1.3800 85.57 18.36 120 0.503820 67'-2 Pf 39.886 1014 21'-0 35.67 8 19.878 Sprinkler, 12'-0 Pe 0.686 101 19'-5 60.450 T(6'-0),P0(6'-0) 79'-2 Pv Route 8 BL 1.3800 17.86 3.83 120 0.027771 9'-10 Pf 0.273 1012 21'-0 33.78 8 17.830 Sprinkler Pe 1015 21'-0 18.104 9'-10 Pv BL 1.3800 51.90 11.13 120 0.199775 6'-11 Pf 2.580 1015 21'-0 34.04 8 18.104 Sprinkler, 6'-0 Pe 116 21'-0 20.683 1(6'-0) 12'-11 Pv RN 1 3800 87.50 18.77 120 0.524962 2'-0 Pf 4.200 116 21'-0 35.59 20.683 Flow(q)from Route 9 6'-0 Pe 0.867 111 19'-0 25.750 P0(6'-0) 8'-0 Pv = Route 9 BL 1.3800 35.59 7.64 120 0.099425 2'-11 Pf 0.887 1016 21'-0 35.59 8 19.796 Sprinkler, 6'-0 Pe 116 21'-0 20.683 T(6'-0) 8'-11 Pv iiii Route 10 RN 1 3800 52.79 11.32 120 0.206174 105'-7 Pf 25.479 117 19'-0 39.078 E(3'-0) 18'-0 Pe -0.181 118 19'-5 64.376 2T(6'-0),E(3'-0) 123'-7 Pv CM 2.6350 52.79 3.11 120 0.008836 12-31/2 Pf 0.109 118 19'-5 64.376 Pe 119 19'-5 64.485 12'-3% Pv CM 2.6350 104.69 6.16 120 0.031350 12'-31/2 Pf 0.385 119 19'-5 51.89 64.485 Flow(q)from Route 13 Pe 120 19'-5 64.870 12'-31/2 Pv CM 2.6350 158.08 9.30 120 0.067202 12'-3% Pf 0.826 120 19'-5 53.40 64.870 Flow(q)from Route 12 Pe 121 19'-5 65.696 12'-3Y% Pv ©M.E.P.CAD,Inc. 411 AutoSPRINK 2020 v16.3.21.0 6/7/2022 7:55:37AM Page 4 i Hydraulic Analysis ` Job Number:1 Report Description:Spec.Warehouse Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length CM 2.6350 214.59 12.63 120 0.118286 7'-2 Pf 2.794 121 19.-5 56.51 65.696 Flow(q)from Route 11 16'-5% P• e 103 19.-5 68.490 T(16'-S1/2) 23'-7% Pv - Route 11 RN 1 3800 56.51 12.12 120 0.233816 105'-7 Pf 30.298 122 19'-0 214.59 35.579 P0(6'-0),Flow(q)from Route 15 24'-0 Pe -0.181 121 19.-5 65.696 2T(6'-0),P0(6'-0) 129'-7 Pv Q Route 12 CM 2 1570 158.08 13.88 120 0.178129 12.-31/2 P• f 2.189 122 19'-0 214.59 35.579 Flow(q)from Route 15 Pe 123 19'-0 37.769 12-3% P• v RN 1.3800 53.40 11.45 120 0.210544 105.-7 Pf 27.282 123 19'-0 37.769 P0(6'-0) 24.-0 Pe -0.181 120 19.-5 64.870 2T(6'-0),P0(6'-0) 129.-7 Pv Route 13 CM 2 1570 104.69 9.19 120 0.083098 12'-3/IPf 1.021 123 19'-0 53.40 37.769 Flow(q)from Route 12 Pe 124 19.-0 38.790 12'-3% Pv RN 1.3800 51.89 11.13 120 0.199688 105'-7 Pf 25.875 124 19'-0 38.790 P0(6.-0) 24.-0 Pe -0.181 119 19'-5 64.485 2T(6'-0) P0(6.-0) 129.-7 Pv OF Route 14 CM 2 1570 52.79 4.64 120 0.023420 12'-3'% Pf 0.288 124 19.-0 51.89 38.790 Flow(q)from Route 13 Pe 117 19.-0 39.078 12'-3% Pv Q Route 15 CM 2 1570 214.59 18.84 120 0.313535 l 12.-3% Pf 3.854 112 19.-0 57 42 31.726 Flow(q)from Route 2 Pe 122 19.-0 35.579 L 12'-3'% P• v Equivalent Pipe Lengths of Valves and Fittings(C=120 only) 1 C Value Multiplier ' Actual Inside Diameter 487 Value Of C 100 130 140 150 ( Schedule 40 Steel Pipe Inside Diameter ) =Factor Multiplying Factor 0.713 1.16 1.33 1.51 i &©M.E.P.CAD,Inc. gAutoSPRINK 2020 v16.3.21.0 6/7/2022 7:55:37AM Page 5 41 Hydraulic Analysis Job Number: 1 Report Description:Spec.Warehouse Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length Pipe Type Legend Units Legend Fittings Legend AO Arm-Over Diameter Inch ALV Alarm Valve BL Branch Line Elevation Foot AngV Angle Valve CM Cross Main Flow gpm b Bushing DN Drain Discharge gpm BalV Ball Valve DR Drop BFP Backflow Preventer DY Dynamic Velocity fps BV Butterfly Valve FM Feed Main Pressure psi C Cross Flow Turn 90° FR Feed Riser Length Foot cplg Coupling MS Miscellaneous Friction Loss psi/Foot Cr Cross Run OR Outrigger CV Check Valve HWC Hazen-Williams Constant RN Riser Nipple DelV Deluge Valve Pt Total pressure at a point in a pipe SP Sprig DPV Dry Pipe Valve ST Stand Pipe Pn Normal pressure at a point in a pipe E 90°Elbow UG Underground Pf Pressure loss due to friction between points EE 45°Elbow Pe Pressure due to elevation difference between indicated Eel 11 Ye°Elbow points Ee2 22%°Elbow Pv Velocity pressure at a point in a pipe f Flow Device fd Flex Drop FDC Fire Department Connection fE 90°FireLock(TM)Elbow fEE 45°FireLock(TM)Elbow flg Flange FN Floating Node fT FireLock(TM)Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap ©M.E.P.CAD,Inc. idAutoSPRINK 2020 v16.3.21.0 6/7/2022 7:55:37AM Page 6 4e> W YAT T F►RE PROTECTION, INC. 9095 S.W. Burnham Tigard,OR 97223 Fire Hydrant Fire Flow PROJECT 16100 SW 72nd Ave ADDRESS 16100 SW 72nd Ave. Tigard, OR CROSS STREET Private hydrant FLOW HYDRANT South end of Building 2. LOCATION STATIC 100 PITOT RESIDUAL 33 GPM 2160 GPM AT 20 PSI 8748, 6% pressure drop calculated per NFPA 291 DATED 5/26/2022 MONITOR HYDRANT SW 72nd Ave. & business park entrance LOCATION — STATIC 100 RESIDUAL 94 DATED 5/26/2022 WITNESS WITNESSED BY Mike Sayti TITLE ORGANIZATION Wyatt Fire Protection SIGNATURE PERFORMED BY Jack Gardner