Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
• OFFICE COPY RECEIVED 2 o 2022 CITY OF TiGARD s�� AFP Systems,Inc. BUILDING DIVISION Automatic Fire Protection 19435 S`.x 129`"Avenue i o Tualatin,OR. 97062 g 's(STEMS / (503)692-9284 yip yi (503)692-1186 fax Pnai/ Submittal Project Name: Jones Sports Co. 7250 SW Durham Rd. #100 Tualatin, OR 97224 For Sage Contractors 8190 SW Durham Rd. Portland, OR 97224 tz.,CO Worldwide Fire Protection Contacts www.tyco-fire.com Products Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverag= r General NOTICE The TYCO Series TY-FRB Sprinkler A' �" JDescription described herein must be installed maintained in compliance with this do. "' ` The TYCO Series TY-FRB,5.6 K-factor, ument, as well as with the applicabl: Upright(TY313)and Pendent (TY323) standards of the National Fire Protec Sprinklers described in this data sheet tion Association,in addition to the stan " T are quick response,standard coverage, dards of any other authorities havin bulb-type decorative 3 mm glassYPspray jurisdiction. Failure to do so may impa -# nT,f r ) sprinklers designed for use in light or the performance of these devices. C ',41- ordinary hazard,commercial occupan- cies such as banks, hotels, and shop- The owner is responsible for maintain r ping malls. ing their fire protection system any devices in proper operating conditio The recessed version of the Series TY- The installing contractor or sprinkl- A A . FRB Pendent Sprinkler,where applica- manufacturer should be contacted with is intended for use in areas with a any questions. finis ceiling.This recessed pendent inkier one of the following: Sprinkler • A t iece le 15 Recessed p Escutche ith ssed adjust- Identification 4 ment upto5/ ' h (1 , m)from , the flush pendent po ` ' n. Number (SIN) ~ �' • A two-piece Style 20 sse Escutcheon with recessed adl - TY313 Upright 5.6K, 1/2"NPT ment up to 1/2 inch (12,7 mm)from TY323 Pendent 5.6K, 1/2"NPT the flush pendent position. � -..:4‘., The The adjustment provided by the Technical Recessed Escutcheon reduces the Temperature Rating accuracy to which the fixed pipe drops Data 135°F(57°C) to the sprinklers must be cut. 155°F(68°C) Approvals 175°F(79°C) Intermediate level versions of Series 200°F(93°C) TY-FRB Sprinklers are described in UL and C-UL Listed 286°F(141°C) Technical Data Sheet TFP357. Sprin- FM,LPCB,and VdS Approved kler guards and shields are described CE Certified Finishes in Technical Data Sheet TFP780. Sprinklers with Polyester Finish are UL Sprinkler:Refer to Table A and C-UL Listed as Corrosion-Resis- Recessed Escutcheon:White Coated, tant Sprinklers. Chrome Plated,or Brass Plated Maximum Working Pressure Physical Characteristics 175 psi(12.1 bar) Frame Bronze 250 psi(17.2 bar)° Button Brass/Copper *The maximum working pressure of 250 psi Sealing Assembly Stainless IMPORTANT (17.2 bar)only applies to the listing by Un- Steel w/TEFLON Always refer to Technical Data derwriters Laboratories,Inc.(UL). Bulb Glass Sheet TFP700 for the "INSTALLER Discharge Coefficient Compression Screw Bronze WARNING"that provides cautions K=5.6 GPM/psitiz(80,6 LPM/barla) Deflector Bronze with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 FEBRUARY 2014 TFP172 TFP172 Page 2 of 4 Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* I / �/ri3^`rc`a r�7r1 T-i-T�� } 5 r�l 7/16" Y I — IMR_ (11,1 mm) 1■Fc NOMINAL ifil 8" 4 ,-- 4 IP MAKE-IN (50,6 mm) I 2 o i� r 2„ ! 1-3/8„ 3 5 (50,8 mm) (34,9 mm) 7NN,11 'I. 1 WRENCH 4 f / FLATS 1 r 1/2"NPT** DEFLECTOR* I-.-- 2-7/8"(73,0 mm)DIA. - .- CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT(TY313)AND PENDENT(TY323)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE L, Operation Installation The glass bulb contains a fluid which The TYCO Series TY-FRB,5.6 K-factor, —00 WRENCH RECESS expands when exposed to heat.When Upright(TY313)and Pendent(TY323) (USE ONLY the rated temperature is reached,the Sprinklers must be installed in accor- END"A") fluid expands sufficiently to shatter the dance with this section. glass bulb, allowing the sprinkler to General Instructions FIGURE 2 activate and water to flow. Do not install any bulb-type sprinkler if W-TYPE 6 the bulb is cracked or there is a loss SPRINKLER WRENCH Design of liquid from the bulb.With the sprin- kler held horizontally, a small air bub- WRENCH Criteria ble should be present. The diameter RECESSC of the air bubble is approximately 1/16 The TYCO Series TY-FRB,5.6 K-factor, inch(1,6 mm)for the 135°F(57°C)and Upright(TY313)and Pendent(TY323) 3/32 inch(2,4 mm)for the 286°F(141°C) �,�r Sprinklers are intended for fire protec- temperature ratings. /t tion systems designed in accordance A leak-tight 1/2 inch NPT sprinkler joint with the standard installation rules rec should be obtained byapplying a min- App it oognized by the applicable Listing or imum to maximum torque f to 14 Approval agency(such as, UL Listing ft.-lbs. (9,5 to 19,0 Nm). Higher levels Sr is based on the requirements of NFPA of torque can distort the sprinkler Inlet �W 13, and FM Approval is based on the with consequent leakage or impairment PUSH WRENCH requirements of FM's Loss Prevention q g p Data Sheets).Only the Style 15 or Style of the sprinkler. INTO ENSURE 20 Recessed Escutcheon is to be used Do not attempt Pt to compensate for WITH SPRINKLER for recessed pendent installations. insufficient adjustment in the Escutch- WRENCHING AREA eon Plate by under-or over-tightening the sprinkler. Re-adjust the position of FIGURE 3 the sprinkler fitting to suit. W-TYPE 7 RECESSED SPRINKLER WRENCH Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1.Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. TFP172 Page 3 of 4 Step 3.Tighten the sprinkler into the 2-7/8"DIA. sprinkler fitting using only the W-Type (73,0 mm) 6 Sprinkler Wrench(Figure 2).With ref- erence to Figure 1,apply the W-Type 6 2-1/4'DIA. Sprinkler Wrench to the wrench flats. FACE OF ~ (57,2 mm) — Torque sprinklers 7 to 14 ft:lbs.(9,5 to SPRINKLER 19,0 Nm). FITTING 5/8"(15,9 mm) Recessed Pendent Sprinklers i \ - FLUSH The Series TY-FRB Recessed Pendent 3/8:5/16" ,,,.,� Sprinklers must be installed in accor- (9,5±7,9 mm) % '% dance with the following instructions. } / �-i- _, Step A.After installing the Style 15 or MOUNTING 1/8" J1 Style 20 Mounting Plate over the sprin- SURFACE (3,2 mm) kler threads, and with pipe-thread --- — sealant applied to the pipe threads, CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) hand-tighten the sprinkler into the TY-FRB PLATE 3/4" sprinkler fitting. (19,1 mm) FIGURE 4 Step B.lighten the sprinkler into the SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) sprinkler fitting using only the W-Type WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 7 Recessed Sprinkler Wrench (Figure RECESSED ESCUTCHEON 3).With reference to Figure 1,apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque 2-7/8"DIA. sprinklers 7 to 14 ft.-Ibs. (9,5 to 19,0 (73,0 mm) Nm). FACE OF Step C.After ceiling installation and fin- SPRINKLER 2-1/4"DIA. ishing,slide on the Style 15 or Style 20 FITTING (57,2 mm) Closure over the Series TY-FRB Sprin- 5/16s1/4" kler and push the Closure over the (7,9±6,4 mm) 1/2"(12,7 mm) Mounting Plate until its flange comes in - FLUSH contact with the ceiling. _J =i j Care and f / - ' 1/8' J 4 Maintenance SUURFACE (3,2 mm) The CO Series TY-FRB,5.6 K-factor, "" Upright(TY313)and Pendent(TY323) CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) Sprinklers must be maintained and ser- TY-FRB PLATE 7/8"(22,2 mm) viced in accordance with this section. FIGURE 5 Before closing a fire protection system SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) main control valve for maintenance WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 work on the fire protection system RECESSED ESCUTCHEON that it controls, obtain permission to shut down the affected fire protection Modified sprinklers must be replaced. standards of any other authorities hay- systems from the proper authorities Sprinklers that have been exposed to ing jurisdiction. Contact the installing and notify all personnel who may be corrosive products of combustion, but contractor or sprinkler manufacturer affected by this action. have not operated,should be replaced regarding any questions. Absence of the outer piece of an if they cannot be completely cleaned by wiping the sprinkler with a cloth or Automatic sprinkler systems are rec- escutcheon, which is used to cover by brushing it with a soft bristle brush. mended to be inspected, tested, a clearance hole, can delay sprinkler and maintained by a qualified Inspec- operation in a fire situation. Care must be exercised to avoid dam- tion Service in accordance with local The owner must assure that the sprin- age to the sprinklers before,during,and requirements and/or national codes. klers are not used for hanging any after installation. Sprinklers damaged objects and that the sprinklers are only by dropping, striking, wrench twist/ cleaned by means of gently dusting slippage,or the like, must be replaced. with a feather duster;otherwise, non- Also, replace any sprinkler that has a operation in the event of a fire or inad- cracked bulb or that has lost liquid from vertent operation may result. its bulb.(Ref.Installation Section.) Sprinklers which are found to be leak- The owner is responsible for the ing or exhibiting visible signs of corro- inspection,testing,and maintenance of sion must be replaced. their fire protection system and devices in compliance with this document,as Automatic sprinklers must never be well as with the applicable standards painted, plated, coated, or other- of the National Fire Protection Associa- wise altered after leaving the factory. tion(e.g., NFPA 25), in addition to the TFP172 Page 4of4 P/N` 77 - XXX - X - XXX SPRINKLER TEMPERATURE FINISH RATINGS SIN 1 NATURAL BRASS 135 135°F(57°C) 370 5.6K UPRIGHT(1/2 NPT) TY313 3 PURE WHITE(RAL9010)' 155 155°F(68°C) POLYESTER 371 5.6K PENDENT(1/2"NPT) TY323 q SIGNAL WHITE(RAL9003) 175 175°F(79°C) POLYESTER .Use suf fix"I"for ISO 7-1 connection; 9 CHROME PLATED 200 200°F(93°C) for example,77-370-4-175-I "Eastern Hemisphere sales only 286 286°F(141°C) TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for avail- www.tyco-fire.com. ability.When placing an order, indicate the full product name and Part Num- ber(P/N). Sprinkler Assemblies with NPT Thread Connections Specify:Series TY-FRB Upright or Pen- dent (specify) Sprinkler, SIN (specify), K=5.6,Quick Response,(specify)tem- perature rating, (specify) finish, P/N (specify,refer to Table A). Recessed Escutcheon Specify:Style 15 Recessed Escutcheon with(specify")finish, P/N(specify") Specify: Style 20 Recessed Escutch- eon with(specify')finish, P/N(specify") Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright©2014 Tyco Fire Products,LP. All rights reserved. NCO TEFLON is trademark of The DuPont Corporation, Fire Protection Products , SCHEDULE 10 9 40 , 009 .1., •tVu. 1 f�` Y j 'ø46 0LL IP .9 lways ready to protect your most valuable assets. As the leading supplier of steel sprinkler pipe,we understand that there are no second chances in fire suppression.You need products of enduring quality and exceptional strength—plus reliable service.You need Bull Moose. Bull Moose Fire Sprinkler Pipe Product Information Nominal Pipe Size(,?[hes) 1" 1-1/4" 1-1/2" 2" 2-1/2" 3" 8" NPS(In.) 1" 1-1/4" 1-1/2" 2" 221/2" 3" 4" 0i.(in) 1315 1.660 1.900 2375 - 3.500 4.500 6.625 8.625 1315 , 1.660 1900 2.375 2.875 3.500 4.500 p I.0.(in) •1 1442 1.682 . 2.635 3260 4.260 6357 8.249 O 1.04' • 1380 1.510 2.067 2.469 3.068 4.026 W Empty Weight(Ib/ft) 1910 .••1 .1 2.640 3.530 4.340 5.520 9.290 15.948 W I.60 ' 2270 2.720 3.660 5900 7.580 10.800 �_ Water Filletl Weight(Ib/ft) 1.820 . : .'- 4.223 5.893 7.957 11.796 23.038 40.086 —1 2.05 2.918 3.602 5.114 7.875 10.783 16.316 O C.R.R. .27 991 7.76 • + 4.92 354 2.50 1.158 1.805 GI 100 , 1.00 100 1.00 1.00 1.00 100 LUI Pieces per Lift 91 61 61 37 1 19 19 10 7 W 70 ' 51 44 30 30 19 19 = Lift Weigh : 21'lengths 2,695 2,319 2,677 2,051 2,224 '2{.J 2,242 1,951 2,490 1=j 2071 ' 2031 2.513 2,306 3b54 3,024 4,309_ �1 ightlibs)24'lengths 3,073 2,650 3,060 2,344 2,542 1,979 - • 2,230 2,848 2,822, 2,778 2,872 2,635 4,176 3,455 4,925 Lift Weight(Ibs)25'lengths 3,208 2,760 3,187 2,442 2,648 2,062 2,670 2,941 , 2,894 2,992 2,745 4,350 3,601 5,130 SCHEDULE +In D 40 ADVANTAGES. OTHER BENEFITS/SERVICES: • UL listed(US&Canada)and FM approved • We have the most stocking locations in the industry, • ASTM A135 and A795 Type E, Grade A Certified • for best delivery and availability • Complies with NFPA-13,13R and 14 Plain end or roll groove • Eddy Guard IF bacterial-resistant internal coating • Industry-leading hydraulic characteristics • Custom length options • CRR of 1.0 and greater • Hot dipped galvanization • All pipe NDT weld tested • Reddi-Pipe' red or black pipe eliminates field painting • Compatible for use in wet,dry, preaction and deluge Exclusive maker of Reddi-Pipe® sprinkler systems RED OR BLACK PAINTED PIPE. • The only maker with EPDs(to help earn LEED points). CERTIFIED �� us LISTED �" 0NISA APPROVED NFF►A ;,,. ..ea.. .. .4. .., fp.4,1.H•, 4N1wr ,... Imo/. ,4 800.325.4467 l l BULL ]V[OOSE', s iesgBulil1 ub IA • F.II o" �` TUBE BullMooseTube.com Victaulic® Vic-FIexTM Sprinkler Fittings ✓ctauIIc, Series AH1 Braided Flexible Hose 10.95 Vic Flex- 1.0 PRODUCT DESCRIPTION Available Sizes by Component • Series AH1 Braided Hose: 31, 36, 48, 60, 727790, 914, 1220, 1525, 1830 mm. Note: length includes adapter nipple and 5.75"/140mm straight reducer. • Sprinkler Reducers: '/i'and 3/4715 and 20mm sprinkler connections and 5.757140mm, 97230mm, 137330mm straight lengths and short, long 90°elbows. Note: The short 90°elbow is typically used with concealed sprinklers while the long 90°elbow is typically used in the installation of recessed pendent sprinklers. • Adapter Nipples: 1"/25 mm NPT or BSPT adapter nipples for attaching to pipe and fittings outlined in NFPA standards. 3/4720mm NPT or BSPT available for VdS. 1'/4"/32mm BSPT available for LPCB. • Brackets: • Style AB1 for suspended and hard-lid ceilings, allows installation before ceiling tiles in place • Style AB2 for suspended and hard-lid ceilings, allows for vertical sprinkler adjustment, and installation before ceiling tiles in place • Style AB3 for surface mount applications, wood, metal and block walls • Style AB4 for hard-lid ceilings with hat furr ing channel grid systems, allows for vertical sprinkler adjustment • Style AB5 for hard-lid ceilings, allows for vertical sprinkler adjustment • Style AB6 for cold storage applications, refer to submittal 10.90 • Style AB7 for suspended and hard-lid ceilings • Style AB7 Adjustable for suspended and hard-lid ceilings • Style AB8 for hard-lid ceilings with CD 60/27 profile metal studs (regionally available) • Style AB9 for hard-lid ceilings with hat furring channel grid systems • Style AB10 for Armstrong®TechZone'"ceilings Maximum Working Temperature • 225°F/107°C Maximum Working Pressure • 200 psi/1375 kPa (FM Approval) • 175 psi/1206 kPa (cULus Listed) • 1600 kPa/232 psi (VdS/LPCB Approved) ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION,MAINTENANCE OR SUPPORT. • System No. Location Spec Section Paragraph Submitted By Date Approved Date • • victaulic.com 10.95 8507 Rev D Updated 10/2016 C 2016 Victaulic Company.All rights reserved. 1 ictaulic' victaulic.con 1.0 PRODUCT DESCRIPTION (Continued) Connections • To adapter nipple(inlet)via 1725.4 mm NPT or BSPT male thread OR • To adapter nipple (inlet)via 14720 mm BSPT male thread(VdS only) • To sprinkler head (outlet)via 'h" or 3715 mm or 20 mm Minimum Bend Radius • 77178 mm (FM Approval) • 3776.2 mm (cULus Listed) • 3"/76.2 mm (VdS/LPCB Approved) Maximum Allowable Sprinkler K-Factors • FM (1/2"/15mm reducer) K5.6/8,1 (S.I.), (3/4720mm reducer) K14.0/20,2 (S.I.) • cULus(' /15mm reducer) K8.0/11,5(S.I.), (3/4"/20mm reducer) K14.0/20,2(S.I.) • VdS/LPCB (' '/15mm reducer) K5.6/8,1 (S.I.), (3720mm reducer) K8.0/11,5(S.I.) 2.0 CERTIFICATION/LISTINGS ® pit, vas LPCB 3.0 SPECIFICATIONS—MATERIAL Series AH1 • Flexible Hose: 300-series Stainless Steel • Collar/Weld Fitting: 300-series Stainless Steel • Gasket Seal: Victaulic EPDM • Isolation Ring: Nylon • Nut and Nipple: Carbon Steel, Zinc Plated • Reducer(1 or 3/4"): Carbon Steel, Zinc-Plated Brackets: Carbon Steel, Zinc-Plated 10.95 8507 Rev D Updated 10/2016 ®2016 Victaulic Company.AD rights reserved. victaulic.com 2 ✓otsulic victaulic.com • 4.0 DIMENSIONS Product Details-Series AH1 Braided Hose Item Description f1 1 Flexible Hose Gi O t4 0. 0 p 2 Isolation Ring 3 Gasket NW 4 Nut --- 5 Branch Line Nipple - - A .� 6 Braid _ `-- e - 7 Collar/Weld Fitting Hose Length Dimensions Hose Length A B inches inches inches mm mm mm 31/790 I 25.25/641 � 31/790 I 36/915 31.25/794 36/915 48/1220 42.25/1073 48/1220 60/1525 54.25/1378 60/1525 72/1830 66.25/1683 72/1830 Standard Reducer I :II:IIIui Ir IIIIII I'.IIIIUIII I♦IIIII IIII IIII I�II� I I�II�II��" 5.757140 mm straight reducer Optional Reducers «l� Ilj 9.0"/229 mm straight reducer Ilillll ll ll IIII IIII IIIIIIII _ EIIIIIIIIIIIIIIIIIIIIIIIIIIII I III III III IIIIIIII 13.07330 mm straight reducer 2.62"/ 66.5 mm 2 �66.55 re mm — — 6.5 m 166.9 m 4.83"/ - 122.7 mm _ L> Short 90°elbow reducer Long 90°elbow reducer NOTE • The Short 90°elbow reducer is typically used with concealed sprinklers while the longer 90 elbow is typically used in the installation of recessed pendent sprinklers. • FM/VdS Approved Only. • • 10.95 8507 Rev D Updated 10/2016 ®2016 Victaulic Company.All rights reserved. victaulic.com 3 �ctaulicr victaulic.com • 4.1 DIMENSIONS VicFlex Brackets Style AB1 • Suspended Ceilings • Hard-Lid Ceilings(FM Only) Item Description r ` 1 24"/610mm or48"/1220mm Square Bark 2 Patented Center Bracket � 3 End Bracket 'Both sizes FM/VdS/LPCB approved,cULus listed r r1 001 I Style AB2 • Suspended Ceilings '23) • Hard-Lid Ceilings Item Description 1 24"/610mm or 4871220mm Square Bar' ;\ 2 Patented Vertically AJustable Center Bracket `� p 3 End Bracket 'Both sizes FM/VdS/LPCB approved,cULus listed �\ 0 Style AB3 • Surface Mount Applications 44.41* `� • FM Approved 10.95 8507 Rev D Updated 10/2016 ®2016 Victaulic Company.All rights reserved. victaulic.com 4 ✓ctaulic` victaulic.com • • 4.2 DIMENSIONS VicFlex Brackets Style AB4 y 0 • Hard-Lid Ceilings with Hat furring I, channel grid system `` Item Description (1) 1 24'/610 mm or 48"/1220 mm Square Bar* 2 Patented Vertically Adjustable Center Bracket 3 End Bracket for Hat Furring Channel 'Both sizes FM/VdS approved,cULus listed >I " Style AB5 • Hard-Lid Ceilings Item Description 1 24"/610mm or 48"/1220 mm Square Bar* ►3 2 Patented Vertically Adjustable Center Bracket 3 End Bracket 'Both sizes FM/VdS approved,cULus listed y p Style AB7 • Suspended Ceilings ,,...704N‘4414444,444N • Hard-Lid Ceilings Item Description 1 24/610 mm or 48"/1220 mm Square Bar* 2 Patented 1 Bee2®Center Bracket r 0 3 End Brackett" Both sizes FM/VdS approved. I43 ry Style AB7 Adjustable • Suspended Ceilings • Hard-Lid Ceilings Item Description r •.9 1 700mm or 1400mm Square Bar* 2 Patented 1-Bee2`Center Brackets)" _ 3 _, End Bracket(adjustable) O 'Both sizes FM/VdS approved. r • • 10.95 8507 Rev D Updated 10/2015 ®2016 Victaulic Company.All rights reserved. victaulic.com 5 ✓ataulic victaulic.com • 4.3 DIMENSIONS VicFlex Brackets Style AB8 lle • Hard-Lid Ceilings vt Item Description — 1 700mm or 1400mm Square Bar` 2 2 Patented Vertically Adjustable Center Bracket 3 "Both sizes FMNd5 'Bath sizes FM/VdS approveC_ r� Style AB9 e • Hard-Lid ceilings with Hat furring channel grid system ill Item 1 Description Ca 3 End Patented 1-B e22 Center Square Barr 1 24"/670mmor48' B e2� Bracket �-�" O Hat Furring Channel 'Both sizes FM/VdS approved. `s t) 110` Style AB10 • Suspended ceilings d • Armstrong®TechZone'" © 0 - k 0 Item Description 1 6"/152mm Square Bar' 2 Patented 1-Beer Center Bracket 3 End Bracket "FM/VdS approved,cULus listed. 10.95 8507 Rev D Updated 10/2016 C 2016 Victaulic Company.All rights reserved. victaulic.com 6 �ctauljc' victaulic.com 4.4 DIMENSIONS CLEARANCES ABOVE CEILING Series AH1 Braided Hose and Style AB1 Bracket Suspended Ceiling Grid with Recessed Sprinkler Suspended Ceiling Grid with Concealed Sprinkler / a / Src(NII P NWw, l vSwcen C�hM� a� a L — — T✓1'1 AY^A , ,.I i I� • i i l�'� LW "-t,„'eP -- —• ' fi .•/fi- 93.m 1 m( ri w. , -- Ill / — eNtl . 1 1=r ,-m,-9d IDS,;II %11'I_, -1 [ R! 1��1 F,ilnJ {{ I pp�✓ �y 1 a ��I'.^I Nerrole./ 1 tt-0IMhm ito, YI" I in99e\ V 6 l brill :$.'/;1 4.l M'A1omm .... /1 Y' -.ham me-' L - m w�ne;ioln .�nl„r.'arc V2707 3/4'/19mm Max.Recess V3802/'/12.7mm Max.Recess Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches inches)inches inches inches,inches inches inches inches.inches inches inches m mm mm mm mm mm mm , m mm mm mm1 mm mm R Minimum 2 3 4 5 6 7 Minimum 2 3 l 4 5 ' 6 7 Bend Radius 50 80 100 125 150 175 R Bend Radius . 50 80 100 125 150 175 10.8 11.8 12.8 13.8 14.8 15.8 10.1 11.1 12.1 13.1 14.1 15.1 A Min. L A Min. 273 298.5 324 349 375 400 269 281 307 1333 358 383 Suspended Ceiling Grid with Recessed Sprinkler with Suspended Ceiling Grid with Concealed Sprinkler with 90° Elbow(Long) 90° Elbow(Short) sq A61 ��FFF�----RRRJJJ �I�I/ '� � l ., -,a 3/ mm 1 i �_ J���1,�1, ICI I Il,n K\ l iil f;i t�IJf: mrivrc Vas .s...�Jl ,Gn.e V2707 3'/19mm Max.Recess V3802 W/12.7mm Max. Recess Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches inches mm mm 8.0 A Min. 00 A .Min. 5.8 1 147 • • 10.95 8507 Rev D Updated 10/2016 ®2016 Victaulic Company.All rights reserved. victaulic.com 7 Jataulicr victaulic.com • 4.5 DIMENSIONS CLEARANCES ABOVE CEILING Series AH1 Braided Hose and Style AB2 Bracket Hard-lid Ceiling with Concealed Sprinkler Hard-lid Ceiling with Recessed Sprinkler / ( t / W/1 M1t '- I I B \ �a n � � 11= I �: Imo:' p' pBiiiiiI • oar rr; e5 -by////l1///n �1�ri!-1i1sm. � ✓lii�l' `k r' N. V7,, :_ 1 a litiiv V3802 1/2712.7mm Max.Recess V2707 3/4719mm Max. Recess Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches inches inches inches Inches inches inches inchesinches,inches inches inches ' mm mm mm mm mm mm Imm mm mm mm mm mm R Minimum 2 3 4 i 5 6 7 I Minimum 2 3 4 5 6 7 Bend Radius 50 80 100 125 150 175 R Bend Radius 50 80 100 125 150 175 A Min. 19368.6 9.6 10.6 116 126 A Min. 6.1 7.1 8.1 9.1 10.1 11.1 I218 1244 1269 295 320 I 155 1180 1206 J 231 256 282 NOTE • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. Hard-lid Ceiling Grid with Concealed Sprinkler with Hard-lid Ceiling with Recessed Sprinkler with 90° Elbow(Short) 90° Elbow(Long) IB v<....m-M Qc —F �i +.. �s r�nBz i/ I,�\p T££ dr (•' F • n IjLo b r m B I- SSSj!(Sj!(iuu "^, x V3802 1/2/12.7mm Max.Recess V27073/4719mm Max.Recess Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches inches mm mm A Min. 27 I A Min. g'6 . • 10.95 8507 Rev D Updated 10/2016 C 2016 Victaulic Company.All rights reserved. victaulic.com 8 ✓ctaulic- 4.6 DIMENSIONS CLEARANCES WITHIN SIDEWALL Series AH1 Braided Hose and Style AB2 Bracket Horizontal Sidewall Sprinkler Horizontal Sidewall Sprinkler with 90° Elbow(Long) 7/i; } wi 1 n,..R_.. I III �!■� u},`'. I'i ��.roa~ ,�/ ai•� 33 9r i r a . . -- - 1 r11 l Py '%l„Af� r�Y/I% / / di x'TI// 7l�/ i%/% l 16 V2707 4719mm Max.Recess V2707 3/4/19mm Max.Recess Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches inches inches Inches inches inches inches mm mm mm mm mm mm mm sn" r.; 'r• ss.trir „y ;<}3'r aK 3 ' a S4 xg° + r 4 a" ♦ b - 4 �,,�y�#� �9�3' =�,a+ =iF*'�Y"" +Fh u1 �"£ ,yF� � r cu' � `�°'�� '�"T�' ,s yyi�'. i';:q'i „,art,,-"s i P':', y n �` .a r� :` "er'�: `Vy t k+a a ,r., Y?' i:*- 4i-0t'e USa4�+ .8� ��,...--arc^--,.8.., �,'�* a�,fit,ws..w:# W af,,,s f ... .=d`�.S r., A Min. 6.1 7.1 8.1 9.1 10.1 11.1 155 180 206 231 256 282 10.95 8507 Rev D Updated 10/2016 C 2016 Victaulic Company.All rights reserved. victaulic.com 9 rrctaulic victaulic.com • 4.7 DIMENSIONS CLEARANCES ABOVE CEILING Series AH1 Braided Hose and Style AB4 Bracket Hat Furring Channel Grid with Recessed Sprinkler L1 N s-. apt • s r/. ."... /. rJ. 1�1 s,.r,F.yi{!rr!3'�/'PrB,✓:�^v / . !a, V2707 W"/19mm Max.Recess Hose Clearance Chart Dimension inches inches inches inches Inches inches mm mm mm mm mm mm R i Minimum 1 2 i 3 1 4 1 5 9 6 1 7 Bend Radius 50 80 100 125 i 150 j 175 A Min. 10.3 11.3112.3 13.3 14.3I15.3 262 287 1313 338 [363.51389_ Hat Furring Channel Grid with Recessed Sprinkler with Hat Furring Channel Grid with Concealed Sprinkler with 90° Elbow(Long) 90° Elbow(Short) i .hl i f i �1��ili1 r - �_ ^... 1' _ ,411 ter r — a i::y r ;.. ffi V2707 V4719mm Max.Recess V2707 344719mm Max.Recess Hose Clearance Chart Hose Clearance Chart Dimension Dimension Inches inches _ mm mm 8.0 A Min. 200 A Min. 5.9 149 NOTE • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. • • 10.95 8507 Rev D Updated 10/2016 ®2016 Victaulic Company.All rights reserved. victaulic.com 10 ✓ctaulice victaulic.com • 4.8 DIMENSIONS CLEARANCES ABOVE CEILING Series AH1 Braided Hose and Style AB5 Bracket Hard-lid Ceiling with Recessed Sprinkler Hard-lid Ceiling with Concealed Sprinkler um v / .,a srM r t moy rr �. � s ' `a� i r ,� °_ I � � �� RI V2707 3/4"/19mm Max.Recess V3802 W/13mm Max. Recess Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches inches Inches inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm mm mm mm R Minimum 2 3 4 5 6 7 8 1 Minimum 2 3 4 5 6 7 i Bend Radius 50 80 100 125 150 175 Bend Radius 50 80 100 125 150 175 A Min. 6.1 7.1 8.1 9.1 10.1 11.1 A Min. 7.6 8.6 9.6 10.6 11.6 12.6 1 155 180 206 231 256 282 193 218 244 269 295 320 I Hard-lid Ceiling with Recessed Pendent with Hard-lid Ceiling with Concealed Pendent with 90° Elbow(Long) 90° Elbow(Short) Sim 1, / }<4 T„ • 'dal �� V t i, r x f cr,eri V3802 1/2713mm Max.Recess V2707 46"/19mm Max.Recess Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches Inches mm mm A Min. 91 A Min. $4 NOTE • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. • • 10.95 8507 Rev D Updated 10/2016 ®2016 Victaulic Company.All rights reserved. victaulic.com 11 \Ctaulic' victaulic.com 4.8 DIMENSIONS (Continued) CLEARANCES ABOVE CEILING Series AH1 Braided Hose and Style AB3 Bracket Surface Mount Application with Recessed Sprinkler C � d A 1 = - 95.3mm CO!4 r, See Note 2rI . r4 A UMW MEI ■Jint>t War 23/8760 mm max.hole 4-- -� 2/51 mm min.hole Hose Clearances Wall Thickness "A" 2 4 6 8 10 2 4 6 8 10 50 100 150 200 250 50 100 j 150 200.250 Outlet Length 5.75 9 13 5.75 9 13 9 13 13 13 5.75` 9 13 5.75 9 13 ! 9 13 13 13 "B" 146.1 228.6 330.2 146.1 228.6 330.2 228.6 330.2 330.2 330.2 146.1 228.6 330.2 146.1 228.6 330.2 228.6 330.2 330.2 330.2. Hose 11.6 14.8 188 9.6 12.8 16.8 10.8 14.8 12.8 10.8 12.6 15.8 19.8 10.6 13.8 17.8 11.8 15.8 13.8 11.8 Clearance"C" 294 376 478 243 325 427 275 376 325 275 319 402 503 268 351 452 300 402 351 300 Bend Radius 7 8 "R" 175 200 NOTE • Variations of ceiling grids,sprinkler heads,brackets,and hoses are permitted but may result in clearance differences from the figures above. • See installation instructions for mounting screw type and size. • 10.95 8507 Rev D Updated 10/2016 C 2016 Victaulic Company.All rights reserved. victaulic.com 12 jataullia victaulic.com 5.0 PERFORMANCE- FRICTION LOSS DATA tar"'� Series AH1 Braided Hose with Stra ight 5.75" Reducers c PL us Style AB1, AB2,AB4,AB5 and AB10 Brackets Series AH1 Hose Maximum Length of Equivalent Length Number of Stainless Steel of 1733.7mm 90°Bends at 3751mm Flexible Hose Outlet Size Sch.40 Pipe(C=120) Bend Radius inches/mm inches/mm/type feet/meters 1/2 715/Straight 52/15.8 _ 3 31/775 3/4720/Straight 55/16.8 3 36/900 1715/Straight 63/19.2 4 3/4'720/Straight 66/20.1 4 48/1200 1/2715/Straight 78/23.8 4 3/4"/20/Straight _ 80/24.4 _ 4 60/1500 1/2715/Straight 88/26.8 4 3/a'720/Straight 90/27.4 ! 4 72/1800 31715/Straight 112/34.1 5 --- _-_ 3720/Straight J 118/36.0 5 . Series AH1 Braided Hose Equivalent Length Design Guide Equivalent length values at various numbers of 90 degree bends at 3751 mm center line bend radius Length of Stainless Steel Flexible Outlet 1 2 3 4 5 Hose Size Bend Bends Bends Bends Bends inches/mm inches/mm feet/meters feet/meters feet/meters feet/meters feet/meters 31/775 -- Y /15 32/9.8 42/12.8 52/15.9 N.A N.A '/20 33/10.1 44/13.4 55/16.8 N.A N.A 1/2715 33/10.1 43/13.1 1 53/16.2 63/19.2 N.A 36/900 3720 36/11.0 46/14.0 56/17.1 66/20.1 N.A 1/2715 46/14.0 57/17 4 68/20.7 j 78/23.8 N.A 48/1200 3/4720 51/15.5 60/18.3 j 71/21.6 88/26.8 N.A 60/1500 -- 1/2'/15 56/17.1 67/20.4 1 77/23.5 88/26.8 N.A 3/4720 58/17.7 69/21.0 80/24.4 90/27.4 N.A 72/1800 1/2/15 69/21.0 79/24.1 91/27.7 102/31.1 112/34.1 3/4"/20 73/22.6 I _ 84/25.6 95/29.0 j 106/32.3 j 118/36.0 NOTES: • Values for use with 5.75'straight reducers. How to use this Design Guide: • For some systems,it may be advantageous for the designer to calculate the system hydraulics using shorter equivalent lengths associated with fewer than the maximum allowable number of bends.In this case,the designer may select a design number of bends for the job and use the associated equivalent length from the design guide to determine the system hydraulics. • It is possible that the actual installed condition of some of the flexible drops may have more bends than the designer selected.When this happens,the design guide may be used to find equivalent lengths based on the actual installed number of bends for particular sprinkler installations.The system hydraulics can be recalculated using actual equivalent lengths to verify the performance of the system. • • 10.95 8507 Rev D Updated 10/2016 ®2016 Victaulic Company.All rights reserved. victaulic.com 13 ✓ctaulicr victaulic.com • 5.0 PERFORMANCE— FRICTION LOSS DATA ® Series AH1 Braided Hose Style AB1,AB2, AB3, AB4, AB5, AB7, AB7 Adj., AB8, AB9 and AB10 VicFlex Brackets Series AH1 Hose Maximum Equivalent Number Length of of 90°Bends 1'133.7mm at 7"/178mm Sch.40 Pipe Bend Radius inches/mm Imperial/S.I. inches/mm/type feet/meters 1/2715/Strai ht 53.8/16.4 31/775 5.6/8.1 _ 9 ____ ___._._.. . ._ 2 'h/15/90°Elbow 53.8/16.4 36/900 5.6/8.1 /:,`/ ajght_ 63.7/19.4 2 h _15/Str 'I ' 15/90°Elbow 63.1/19.2 48/1200 5.6/8.1 17/15/Straight____ 87.9/26.8 __ 3 '/ /15/90 Elbow 85.8/26.1 60/1500 5.6/8.1 715/Straight 112.2/34.1 _ 4 h' 15/90°Elbow 108.4/33.0 '1/272/1800 5.6/8.1 "/15/Straight _ 136.5/41.6 4 'k"/15/90`Elbow - 131.1/39.9 14'/20/Strai ht _ 44.4/13.5 31/775 8.0/11.5 I- 3/4720/90`Elbow 47.6/14.5 2 36/900 8.0/11.5 _ '4720/Straight 55.6/16.9 2 _I_ %... /20/90°Elbow 57.5/17.5 720/Straight 82.8/25.2 3 /4 48/1200 8.0/11.5 3 /20/90'Elbow _ 81.7/24.9 4 60/1500 8.0/11.5 aid"/20/Straight 110.1/24.9 3/4720/90"Elbow l 105.9/32.2 _... -3- 72/1800 8.0/1 LS '/4"/20/Strai ght : 137.3/418 4 a 3/20/90'Elbow 130.2/39.7 /4/20/Straight _ 45.5/13.8 I 31/775 11.2/16.1 3/./20/90°Elbow 47.1/14.3 2 36/900 11.2/16.1 14/20/Straight 66.3/20.2 2 3/4720/90'Elbow 57.5/17.5 48/1200 11.2/16.1 4720/Straight __82.7/25.2 — 3 3/4720/90°Elbow 82.8/25.2 60/1500 11.2/16.1 '>._ 34'/20/Straight __ _— 109.1/33.2 4 3/4720/90°Elbow 108.1/32.9 72/1800 11.2/16.1 3/4°/20/Straight 135.5/41.3 4 374720/90°Elbow 133.4/40.6 31/775 14.0/20.2 3 '/20/Straight 44.3/13.5 2 3/4720/90°Elbow 46.4/14.1 3 720/Straight 55.5/16.9 _ 36/900. 14.0/20.2 3 "/20/90°Elbow - 56.7/17.3 2 48/1200 i 14.0/20.2 3 d3/20/Straiqht 83.0/25.3 3 720/90°Elbow 82.1/25.0 W/20/Straight _ 110.4/33.6 60/1500 14.0/20.2 14/20/90'Elbow 107.5/32.7 -- 4 3/4"/20/Strai ht 137.9/42.0 72/1800 14.0/20.2 3 '/20/90°Elbow --- 132.8/40.4 � 4 FM NOTES: • Series AH1 has been tested and Approved by FM Global for use in wet,dry and preaction systems per NFPA 13,13R,and 13D and FM data sheets 2-0,2-5, and 2-8.FM 1637 and Vds standards for safety include,but are not limited to,pressure cycling,corrosion resistance,flow characterisitics,vibration resistance, leakage,mechanical and hydrostatic strength. • Differences in equivalent lengths are due to varying test methods,per FM 1637 and VdS standards.Refer to these standards for additional information regarding friction loss test methods. • EXAMPLE:A 48-inch hose installed with two 30°bends and two 90°bends at a 7-inch bend radius is permitted and considered equivalent to the data in the • table shown above.In this example,the total number of degrees is 240°,which is less than the allowable 270°. • • • 10.95 8507 Rev D Updated 10/2016 C 2016 Victaulic Company.All rights reserved. victaulic.com 14 ✓ctaulia victaulic.com 5.0 PERFORMANCE- FRICTION LOSS DATA VdS1Series AH1 Braided Hose Style AB1, AB2,AB4, AB5, AB7,AB7 Adj.,AB8, AB9,and AB1O Brackets Series AH1 Hose Equivalent Length of Maximum Number Length of steel pipe according to of 90°Bends at Stainless Steel Outlet EN 10255 DN 20 3'776.2mm Bend Flexible Hose Size (26,9 x 2,65) Radius mm/inches mm/inches/type meters/feet meters/feet 790/31 15mm/rh'/Straight ____ 4.0/12.9 ? 3 20 mm/3 "/Straight _ 15mm/V3"/Straight_ _— 915/36 20mm/3"/Straight 4.6/15.0 3 1220/48 ____ 15mm/'"/Straight 6.1/20.0 3 20 mm/3/i"/Straight______ ___15mm//"/Straight 1525/60 20 mm/k/Straight 7.6/25.0 4 i5mm/3/z"/Straight 1830/72 9.2/30.0 4 20mm/3h"/Straight VDS CEILING MANUFACTURERS LIST AB1,AB2,AB7,AB10 AB4/9 AB8 1.AMF No specific approval 1.Hill 2.Armstrong 2.Knauf 3.Chicago Metallic 3.Lafarge 4.Dipling 4.Lindner 5.Durlum 5.Rigips 6.Seidel 7.Gema-Armstrong 8.Hilti 9.Knauf 10.Lafarge 11.Linder 12.Odenwald 13.Richter 14.Rigips 15.Rockfon Pagos 16.Suckow&Fischer 17.USG Donn LPCB Series AH1 Braided Hose Style AB1 Bracket Series AH1 Hose Series AH1 Hose Length of j Equivalent Length Maximum . Length of Equivalent Length Maximum Stainless I of steel pipe Number of I Stainless of steel pipe Number of Steel according to 90°Bends at Steel according to 90°Bends at Flexible Outlet EN 10255 DN 3'y76.2mm Flexible Outlet EN 10255 DN 25 3176.2mm !, Hose Size (33,7 x 3,25) Bend Radius ', Hose Size (33,7 x 3,25) Bend Radius mm/inches mm/inches/type meters/feet mm/inches mm/inches/type meters/feet 15mm/1/2"/Straight 15mm/1/2"/90°Elbow 1 790/31 20mm/?/Straight 12.7/41.8 2 790/31 -20mm/A"/90°Elb w 13.6/44.6 2 15mm/n/Straight 15mm/%z/90°Elbow 915/36 16.4/53 8 3 915/36 ----- 16.9/55.4 3 _.. -. 20 mm/?�</Straight �.__.._ 20 mm/3/°/90°Elbow.] 1220/48 i5mm/Ya"/Straight 19.6/64.3 3 1220/48 _15mm/'/z"/90°Elbow 19.9/65.1 3 20 mm/3/n3b"/90°Elbow 15mm/'/2"/Straight 15mm/Vv/90°Elbow 1525/60 24.0/78.8 3 1525/60 24.5/80.2 3 20 mm//< 20mmJ/°/Straight 20mm/3/<"/90°Elbow 15mm//z' 1 nk /Straight 28.5/934 3 1 1830/72 i5mm "/90°Elbow 1830/72 _ 27.8/91.1 3 3 /Straight 1 i 20mm/3/<"/90°Elbow 10.95 8507 Rev D Updated 10/2016 ®2016 Victaulic Company.All rights reserved. victaulic.com 15 ✓ctaulic' victautic.com 6.0 NOTIFICATIONS A WARNING • It is the responsibility of the system designer to verify suitability of 300-series stainless steel flexible hose for use with the intended fluid media within the piping system and external environments. • The effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on 300-series stainless steel flexible hose must be evaluated by the material specifier to confirm system life will be acceptable for the intended service. Failure to follow these instructions could cause product failure, resulting in serious personal injury and/or property damage. 7.0 REFERENCE MATERIALS—CHARACTERISTICS Flexible Hose In-Plane Bend Characteristics One Bend Two Bends Three Bends x 2X Minimum Minimum Minimum bend radius ( bend radius bend radius OR Minimum OR bend radius 90a Minimum, \l L -- — bend radius Minimum Minimum bend radius bend radius Minimum bend radius Minimum bend radius NOTE • For out-of-plane(three-dimensional)bends,care must be taken to avoid imparting torque on the hose. • User Responsibility foe Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications.All products Victaulic products for a particular end-use application,in accordance with industry to be Installed In accordance with current Victaulic installation/assembly instructions. standards and project specifications,and the applicable building codes and related Victaulic reserves the right to change product specifications,designs and standard regulations as well as Victaulic performance,maintenance,safety,and warning equipment without notice and without incurring obligations. instructions.Nothing in this or any other document,nor any verbal recommendation, Installation advice,or opinion from any Victaulic employee,shall be deemed to alter,vary,supersede, Reference should always be made to I-VICFLEX-AB1-AB2-ABIO,I-VICFLEX-AB4-AB9, or waive any provision of Victaulic Company's standard conditions of sale,installation I-VICFLEX-AB7,or I-VICFLEX-ABS for the product you are installing.Handbooks are guide,or this disclaimer. included with each shipment of Victaulic products for complete installation and assembly Intellectual Property Rights data,and are available in PDF format on our website atwww.victaulic.com. No statement contained herein concerning a possible or suggested use of any material, *meaty product,service,or design is intended,or should be constructed,to grant any license Refer to the Warranty section of the current Price list or contact Victaulic for details. under any patent or other Intellectual property right of Victaulic or any of its subsidaries or affiliates covering such use or design,or as a recommendation for the use of such Trademarks material,product,service,or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of property right.The terms"Patented"or"Patent Pending"refer to design or utility patents Victaulic Company,and/or its affiliated entities,in the U.S.and/or other countries. or patent applications for articles and/or methods of use In the United States and/or other countries. 10.95 8507 Rev C Updated 10/2016 C 2016 Victaulic Company.All rights reserved. victaulic.com 16 ✓ctaulifa IPS CARBON STEEL PIPE -HOLE CUT PRODUCTS 10.52 FireLock° Outlet-T ® LPCB SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating 1/2,3/4,and 1'/15,20 and 25mm outlets for directly connecting sprinklers,drop nipples,sprigs,gauges,drains and other outlet products.Available for 11/4 through 76.1 mm/32 to 76.1mm piping systems,Style 922 outlets are UL/ULC Listed,LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe.When tightened,the assembly compresses the gasket onto the OD of the pipe.The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard,lightwall,Schedule 5 and other specialty pipes.' Contact Victaulic for other optional coatings. `Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing:Ductile iron conforming to ASTM A-536,grade 65-45-12.Ductile iron conforming to ASTM A-395,grade 65-45-15,is available upon special request. Gasket: • Grade"E"EPDM-Type A (Violet color code).FireLock products have been Listed by Underwriters Laboratories Inc.and Approved by Factory Mutual Research for wet and dry(oil free air)sprinkler services up to the rated working pressure using the Grade"E"Type A Gasket System. Bolts/Nuts:Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: • Orange enamel(North America,Latin America,Asia Pacific) • Red enamel(Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.02009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. •CtauluG' REV_G 10.52 1 IPS CARBON STEEL PIPE-HOLE CUT PRODUCTS 10.52 FireLock® Outlet-T STYLE 922 DIMENSIONS Nominal Size Hole p PProz. inches/min Diameter Dimensions inches/m Jhmelers Weight Each %Branch ♦0 06R1 5 Y I-ZJ FP1 -000/.00 T* V W Y Z Ibs/kg 1 N 1/2 1Mt 130 1.83 1.10 3.87 2.56 1.0 V 32 x 15 302 33.0 46.5 27.9 98.3 650 0.45 14 115e 1.28 1.83 46.5 1.10 3.87 256 1.1 } n �r 1 20 _ 30.2 32.5 27.9 I 98.3 65.0 0.50 '1, per' yy 1 161a 1.52 218 1.10 3,87 256 L2 \_/ 1 I 25 302 386 554 279 98.3 650 0.54 Ph X Y 13A6 1.42 1.95 1.22 ,_...4,08 2.56 1.2 40 15 30,2 36.1 49.5 ' 31.0 L 103.6 65.0 0.54 $ 1 YI6 1.40 1.95 I 1.22 i 4.08 2.56 1.2 20 30.2 35.6 495 31.0 103.6 65.0 0.54 1 IOU 1.64 2.30 1.22 f 4.08 2.56 1.3 25 30.2 41.7 58.4 31.0. 1 103.6 65.0 . 0.59 2 x '1/2136e 166 2.19 1.46 4.60 2,56 1.3 50 15 30.2 42.2 55.6 371 ; 116.8 65.0 0.59 N 1%16 1.64 219 1.46 4.60 2.56 1.4 20 30.2 41.7 55.6 . 37.1 116.8 65.0 j 064 1 1'/ie 1.88254 1.46 4.60 256 1.5 25 302 478 64.5 37.1 116.8 65.0 I 0.68 21/2 x 1 13Ae 1.91 2.44 171 5.40 2.56 1.6 65 15 30.2 48.5 67.0 43.4 13/.2 65,0 0.73 3/4 13/46 1.89 i 2.44 1.71 5.40 2.56 1.6 20 30.2 48.0 1 62.0 43.4 1372 65.0 0.73 1 1 Y16 2.13 I 2.79 1.71 5.40 2.56 1.6 25 30,2 54.1 70.9 43.4 137.2 65.0 0.73 76.1 min X 3/413/,e 1.91 2.44 1.71 5.50 2.56 1.6 15 30.2 48.5 620 43.4 139,7 65.0 0.73 3A 13Ae 1.89 2.14 1.71 5,50 2.56 1.6 20 30.2 48.0 62.0 43.4 139.7 65.0 0.73 1 13Ae 2.13 2.79 1.71 5.50 2.56 1.7 25 30.2 54.1 70.9 43.4 139.7 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT(optional) male pipe threads only.Use of male threaded products with special features,such as probes,dry pen- dent sprinklers,etc.,should be verified as suitable for use with this Victaulic product.Failure to verify suitability in advance may result in assembly problems or leakage. *Center of run to engaged pipe end for NPT threads(dimensions are approximate). www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2U VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICt8UI.C' IN 10.52_2 REV_G IPS CARBON STEEL PIPE-HOLE CUT PRODUCTS 10.52 FireLock® Outlet-T STYLE 922 PERFORMANCE Equivalent Length of 1 inch Schedule 40 Steel Pipe(per UL Run Size c Outlet Size 213,Section 16)(Cn120)',PT Inches/mm" em �..FeeUmeters 1 Ye X 1 8.5 32 25 2.6 1 Yv X 1 8.5 40 25 2 6 2 X 1 8.5 50 25 2.6 21/2 X 1 8.5 65 25 2.6 76.1 mm X 1 8.5 25 2.6 'Hazen-Williams coefficient of friction is 120 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.02009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ictaulic' REV_G 10.52 3 IPS CARBON STEEL PIPE-HOLE CUT PRODUCTS 10.52 FireLock® Outlet-T STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing.Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 10.52 3355 REV G UPDATED 1212009 - �Ctaul.0 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULC COMPANY.C 2O09 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 10.52