Loading...
Report OFFICE COP, PATRIOT 4708 NE MINNEHAHA ST VANCOUVER,WA 98661 FIRE PROTECTION INC. ��yy77 ��//��//��(�22 TEL(360)sss-aao3 G{[.L.ull�BJ FAX(360)699-4485 .it_t.j 4 2022 Fire Protection 3UILDIN FDIVISIONI Material and Equipment Submittal for Tigard Senior Housing Tigard , OR 8815 SW Omara Street Tigard, OR 97223 PRaRior Job #31 -1544 TACOMA,WA OFFICE www.patriotfire.com SPOKANE,WA OFFICE TEL(253)926-2290 PATRI P099CF/CCB#70822 TEL(509)926-3428 FAX(253)922-6150 FAX(509)926-3708 PATRIOT 4708 NE MINNEHAHA ST FIRE PROTECTION INC. VANCOUVER,WA 98661 TEL(360)699-4403 FAX(360)699-4485 FIRE PROTECTION MATERIA 31-1544 Tigard Senior Housing 8815 SW Omara Street Tigard, OR 97223 Designer:Kevin Long ITEM MANF. MODEL SIZE COMMENTS ***SPRINKLERS*** K.NPT 1-1 SSU, SSP, HSW, REC SSP Reliable F1FR56 5.6K, 1/2" Non residential areas 1-2 Combustible Concealed Space SSU Reliable KFR-CCS 5.6K, 1/2" 1-3 Recessed Residential SSP Reliable KRes49 4.9K, 1/2" Residential areas ***VALVES*** 2-1 Gr000ved Butterfly Valve Reliable BFG-300-1 2-1/2",4" Built-in tamper switch 2-2 CR Commercial Riser Reliable CR Riser 2-1/2" &4" With water flow switch, gauge and test and 2-3 Groove Inlet Angle Hose Valve FPPI GR x MNST 2-1/2" With cap and chain ***ELECTRICAL*** 3-1 Electric Bell Potter MBA-10-12 10" 120 VAC ***PIPE*** 4-1 CPVC Pipe BlazeMaster 1"thru 2" 4-2 Steel Pipe State Pipe Sch. 10 Black 2"thru 4" Or equal manufacturer 4-3 Steel Pipe State Pipe Sch.40 Black 1"thru 2" Or equal manufacturer ***FITTINGS*** 5-1 Grooved Fittings Victaulic Varies 1 1/4"thru 4" 5-2 CPVC Fittings BlazeMaster Varies 1"thru 2" ***HANGERS/SEISMIC BRACING*** 6-1 Steel Pipe Hangers Tolco Varies As Required 6-2 CPVC Pipe Hangers Tolco Varies As Required 6-3 Seismic Bracing Tolco Varies As Required ***MISCELLANEOUS*** 7-1 Fire Caulk Hilti FS-ONE - 7-2 Sprinkler Wrench Reliable As Required 7-3 Pressure Gauge Winters 300 PSI Bulletin 014 December 2021 W ® Model Fl FR Series TT Reii a e ..t Quick Response o l. Glass Bulb Sprinklers o 3 CT Model F1 FR56 Sprinkler Types Standard Spray Upright E - _. ^' Standard Spray Pendent #y+` ' Conventional Upright/Pendent rr t� I Vertical Sidewall fit Horizontal Sidewall _a r ! ` 0 Model F1 FR56 Recessed Sprinkler Types Upright Pendent Conventional Standard Spray Pendent r, to Horizontal Sidewall x Model F1 FR56 Concealed Sprinkler Types $ ' x Standard Spray Pendent -, ' _ r , C Model F1FR42, F1 FRXLH & F1 FR28 Sprinkler csi � ';: a Types Standard Spray Upright Vertical Sidewall Horizontal Sidewall Recessed v Standard Spray Pendent Pendent/F1/F2 Y Model F1 FR40 Sprinkler Types " k Standard Spray Pendent t. i o Model F1 FR42, F1FR40, FI FRXLH & F1FR28 , = Recessed Sprinkler Types z Standard Spray Pendent ,' -. .-, ,r • .,, . ',;'. k', ' Model FIFR56LL&FIFR42LL Low Lead Sprinkler Rec essed Concealed Recessed a Horizontal Sidewall Pendent Pendent/FP 76 Types $ Standard Spray Pendent with less than 0.25% Lead Con- tent o ,r a 0 Listing &Approvals t - � '.6) The following organizations provide Listings or Approvals for x' �- ,A 3 various Model F1FR series sprinklers. See the Design and .. 8 Installation table in this Bulletin for information on specific listings and approvals applicable to each sprinkler. XLH Upright XLH Pendent XLH Recessed m 1. Underwriters Laboratories Inc.and Certified for Cana- PendentFl/F2 a da(cULus)in accordance with ANSI/UL199. Product Description rii 2. FM Approvals(FM) Reliable Model F1FR series sprinklers , r- v% . z3. Loss Prevention Certification Board(LPCB) are quick response automatic sprinklers ", N 4. VdS SchadenverhUtung GmbH (VdS) with a glass bulb thermal element. Model ,. - N5. Underwriters Laboratories Inc. and Underwriters Lab- F1FR series sprinklers are Standard Spray c oratories of Canada Certified for Health Effects to NSF/ sprinklers,with the exception of the Model ANSI Standard 61 Annex G (ULH) F1 FR56 Conventional sprinkler which is XLH Recessed 6. EC Certificate: 0786-CPD-40239 (RA1414), 0786- an Old-style/Conventional sprinkler. Pendent FP CPD-40251 (RA1425), 0786-CPD-40252 (RA1475) The Model F1FR Series automatic sprinklers utilize a 3.0 (EC) mm frangible glass bulb. These sprinklers have demonstrated 7. (EC) certified. Certificate Number 23347.(WM) response times in laboratory tests which are five to ten times ULListing WaterMark Category faster than standard response sprinklers. This quick response enables the Model F1FR Series sprinklers to apply water to a Sprinklers,Automatic&Open(VNIV) fire faster than standard-response sprinklers of the same tern- Quick Response Sprinkler perature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manufac- tured glass capsule.This glass bulb is specially constructed to provide fast thermal response. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 At normal temperatures, the glass bulb contains the fluid in Model Fl FR Series sprinklers must be installed with the Reli- both the liquid and vapor phases.The vapor phase can be seen able sprinkler installation wrench identified in the Design and as a small bubble.As heat is applied,the liquid expands,forcing Installation Information table in this Bulletin. Any other wrench the bubble smaller and smaller as the liquid pressure increases. may damage the sprinkler. A leak tight sprinkler joint can be Continued heating forces the liquid to push out against the bulb, obtained with a torque of 8 to 18 lb-ft(11 to 24 N-m). Do not causing the glass to shatter,opening the waterway and allowing tighten sprinklers over the maximum recommended installation the deflector to distribute the discharging water. torque. Exceeding the maximum recommended installation Model F1FR Series sprinklers provide a wide range of options torque may cause leakage or impairment of the sprinkler. where quick-response,glass bulb sprinklers are used: Recessed Sprinklers • Pendent, recessed pendent, upright, horizontal side- Model Fl FR Series Recessed sprinklers are to be installed wall, and vertical sidewall deflectors as shown in Fig. 1, Fig.2,or Fig.3,as applicable to the specific • K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 model being installed.The Recessed Escutcheon Data table in metric),and 5.6 (80 metric) the Bulletin identifies the only recessed escutcheons that are • Flush,recessed, and concealed installations permitted to be used with each Model F1FR Series Recessed See the Design and Installation Information table in this Bul- sprinkler.The use of any other recessed escutcheon will void all 5 letin for information on the approvals and availability of specific approvals and negate all warranties. Model F1FR series sprinkler configurations. Concealed Sprinklers cn Model F1FR Recessed Pendent and Recessed Horizontal Model F1FR Series Concealed Pendent sprinklers are to x Sidewall sprinklers are required to be used with Reliable Model be installed as shown in Fig. 4 or Fig. 5, as applicable to the x F1, F2, or FP recessed escutcheons. See the Recessed Es- selected cover plate. Model F1FR56 Concealed Pendent and m cutcheon Data table in this Bulletin for listing and approval infor- Model F1 FR56LL Concealed Pendent sprinklers have a facto- N mation with each specific Model Fl FR series sprinkler. Model ry-installed Model CCP cup.A protective cap is installed at the Y F1 and F2 recessed escutcheons, shown in Fig. 1 and 3, are factory that should remain on the sprinkler until the sprinkler is a friction fit assembly allowing for 3/4-inch (19mm) and 1/2- installed and should then be reinstalled on the sprinkler until the Y inch(12.7mm)of adjustment, respectively.Model FP recessed cover plate is installed.The concealed sprinkler assemblies are , escutcheons, shown in Fig. 2, provide a 1/2-inch (12.7mm) completed by the installation of a Model CCP push-on/thread- Y threaded adjustment. off cover plate assembly.The cover plate and sprinkler cup as- o Model F1 FR56 Concealed Pendent and Model F1 FR56LL semblies are joined using a cover plate skirt with flexible tabs co Concealed Pendent sprinklers are required to be used with for threaded engagement. A choice of two Model CCP cover °.72 Model CCP cover plates.A standard profile Model CCP cover plate assemblies provides either 1/2-inch (13mm) or 5/8-inch • plate is available that provides up to 1/2-inch(12.7mm)of cover (8mm)of cover adjustment. Do not install Model Fl FR Series 47 plate adjustment. In addition, a low profile Model CCP cover Concealed Pendent sprinklers in ceilings which have positive CO plate is also available that provides up to 5/16-inch(8.0mm)of pressure in the space above. cover plate adjustment. See the Design and Installation Infor- Model F1FR Series Concealed Pendent sprinklers require w mation and Listed and Approved Temperature Ratings tables a 2-5/8-inch(67mm) diameter hole to be cut in the ceiling. The :: in this Bulletin for further information on approved cover plate Model W4 wrench is used to engage the sprinkler wrenching sur- la options. faces and to install the sprinkler in the fitting.Remove the protective Application cap to install the sprinkler,then reinstall the protective cap until the H Model F1FR Series sprinklers are intended for use in ac- cover plate is installed.When inserting or removing the wrench from CD cordance with NFPA 13, FM Property Loss Prevention Data the sprinkler/cup assembly,care should be taken to prevent dam- m Sheets,and the requirements of the Authority Having Juris- age to the sprinkler.Do not wrench any other part of the sprinkler/ a. diction. Care must be exercised that the k-factor, tempera- cup assembly.Installation is completed by removing the protective ai ture rating, deflector style, and sprinkler type are in accor- cap from the sprinkler and pushing the cover plate onto the cup. o z dance with the requirements of the applicable design and Final adjustment is made by hand turning the cover plate until the N installation standards. In addition, Model F1FR Series sprin- skirt flange makes full contact with the ceiling.Cover plate removal N klers must be used in accordance with their listings and ap- requires turning the cover plate in the counter clockwise direction. 00 • provals, as well as the information provided in this Bulletin. After installation,inspect all sprinklers to ensure that there is a gap Installation between the cover plate and ceiling and that the four cup slots are Glass bulb sprinklers have orange bulb protectors or protec- open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use tive caps to minimize bulb damage during shipping, handling and installation. Reliable sprinkler installation wrenches are with specific sprinklers.The use of any concealed cover plate/ designed to install sprinklers with bulb protectors in place. Re- cup assembly other than the Reliable Model CCP with Model move the bulb protector at the time when the sprinkler system is F1 FR56 Concealed Pendent and Model F1 FR56LL Concealed placed in service for fire protection.Removal of the bulb protec- Pendent sprinklers or the use of the Model CCP Concealed tor before this time may leave the bulb vulnerable to damage. cover plate assembly on any sprinkler with which it is not spe- Remove bulb protectors by undoing the clasp by hand. Do not cifically listed my prevent good fire protection and will void all use tools to remove bulb protectors. guarantees,warranties,listings and approvals. 2. Technical Data: Sensitivity:Quick-response Thread Size: 1/2-inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar)- 100%Factory tested hydrostatically to 500 psi(34.5 bar) SIN RA1425, RA1414& RA1435 cULus listed for 250 psi(17 bar) Design and Installation Information Nominal Nominal Nominal K-factor Orifice Deflector/ Sprinkler Installation Listings Approval Model Diameter Orientation Height Wrench SIN and Notes Approvals US Metric inches mm inches mm Pendent 2.25 57 W2 RA1411 cULus 2 E F1FR28 2.8 40 3/8 10 Recessed Pendent 2.25 57 W4 RA1411 cULus 2 o Upright 2.25 57 W2 RA1421 cULus 1,2 I M c Pendent 2.25 57 W2 RA1418 VdS F1FR40 4.0 57 3/8 10 rn Recessed Pendent 2.25 57 W4 RA1418 VdS = Pendent 2.25 57 W2 RA1413 cULus 2 X F1FR42 4.2 60 7/16 10 Recessed Pendent 2.25 57 W4 RA1413 cULus 2 co c Upright 2.25 57 W2 RA1423 cULus 1,2 I F1FR42LL 4.2 60 7/16 10 Pendent 2.25 57 W2 RA1410 cULus,ULH Y Recessed Pendent 2.25 57 W4 RA1410 cULus,ULH c F1FRXLH Pendent 2.25 57 W2 RA1413 cULus 2 Y (F1FR42 4.2 60 7/16 10 Recessed Pendent 2.25 57 W4 RA1413 cULus 2 with Pintle) Upright 2.25 57 W2 RA1423 cULus 1,2 Y cULus,FM, o Pendent 2.25 57 W2 RA1414 LPCB,VdS,EC, 1,2,3,4 c WM o cULus, FM, y Recessed Pendent 2.25 57 W4 RA1414 LPCB,VdS,EC, 1,2,3,4 > WM d F1FR56 5.6 80 1/2 15 cULus,VdS,EC, v Concealed Pendent 2.25 57 W4 RA1414 WM 5,6 D. cULus,FM, o Upright 2.25 57 W2 RA1425 LPCB,VdS,EC, 1,2,3,4 m WM a "Conventional LPCB,VdS,EC, 3 (Pendent or Upright)" 2.25 57 W2 RA1475 WM 4 a' Pendent 2.25 57 W2 RA1415 cULus,ULH 1 m m F1FR56LL 5.6 80 1/2 15 Recessed Pendent 2.25 57 W4 RA1415 cULus,ULH m Concealed Pendent 2.25 57 W4 RA1415 cULus,ULH 6 a. Horizontal Sidewall 2.63 67 W2 RA1435 cULus,FM 1,2,3,7 uj F1FR56 5.6 80 1/2 15 Recessed Horizontal 2.63 67 W4 RA1435 cULus,FM 8 ~O Sidewall Z Vertical Sidewall(Pen- cULus,FM, F1FR56 5.6 80 1/2 15 2.25 57 W2 RA1485 1,2,3,9 M dent or Upright) LPCB 0 C')cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. m (3)cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. (3)Available with FM approved Polyester coating in black or white. (6)Available with LPCB and VdS approved Polyester coating. (54 VdS and EC approvals of the F1FR56 Concealed Pendent sprinkler are for 155°F(68°C)temperature rated sprinklers only.VdS approved sprinklers must use Norbulb brand glass bulbs with the 1/2-inch(12.7mm)adjustment Model CCP cover plate only. (6)Model F1FR56 Concealed Pendent and Model F1 FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates,available as either standard depth with 1/2-inch(12.7mm)of adjustment or low profile with 5/16-inch(8.0 mm)of adjustment. (')cULus Listing of the F1FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. Minimum to maximum deflector to ceiling distance shall be 4 inches to 12 inches(102mm to 305mm).FM Approval of the F1FR56 Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (8)cULus Listing and FM Approval of the F1 FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (e)The F1FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies.LPCB approval of the F1FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. 3. Listed and Approved Temperature Ratings Ordinary Temp. Intermediate Temp. High Temp. Classification Classification Classification Deflector) 100°F(38°C)Max.Ambient 150°F(65°C)Max.Ambient 225°F(107°C)Max. Model Temp. Temp. Ambient Temp. Orientation 135°F(57°C) 155°F(68°C) 175°F(79°C) 200°F(93°C) 286°F(141°C)Temp. Temp.Rating Temp. Rating Temp.Rating Temp.Rating Rating Orange Bulb Red Bulb Yellow Bulb Green Bulb Blue Bulb Pendent cULus F1FR28 Recessed Pendent cULus Upright cULus F1FR40 Pendent VdS Recessed Pendent VdS Pendent cULus F1FR42 Recessed Pendent cULus y Upright cULus c F1FR42LL Pendent cULus,ULH .Q Recessed Pendent cULus,ULH v) Pendent cULus = FIFRXLH Recessed Pendent cULus X Upright cULus c Pendent cULus,FM,LPCB,VdS,EC,WM as Recessed Pendent cULus,FM,LPCB,VdS,EC,WM r cULus,VdS,EC, Y FIFR56 Concealed Pendent` cULus,WM WM cULus,WM c Upright cULus,FM,LPCB,VdS,EC,WM `" "Conventional LPCB,VdS,EC,WM a (Pendent or Upright)" Y Pendent cULus,ULH o F1FR56LL Recessed Pendent cULus,ULH W Concealed Pendent° cULus,ULH o Horizontal Sidewall cULus,FM L' FIFR56 Recessed Horizontal > Sidewall cULus,FM o Vertical Sidewall(Pen- as F1 FR56 dent or Upright) cULus,FM,LPCB D. * Model Fl FR56 Concealed Pendent and F1 FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP o cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C)temperature rated cover plate. For In- A' termediate Temperature Classification sprinklers use a 165°F(74°C)temperature rated cover plate. (0 .0 a) aa)i Recessed Escutcheon Data a) to Listed and Approved Recessed Escutcheons a Model F1 Model F2 Model FP /6 Deflector! a) Model (Fig.1 &3) (Fig.1&3) (Fig.2) SIN a. Orientation w 3/4-inch(19mm) 112-inch(12.7mm) 1/2-inch(12.7mm) F- adjustment adjustment adjustment z FIFR28 Recessed Pendent cULus cULus cULus RA1411 N FIFR40 Recessed Pendent VdS VdS VdS RA1418 N FIFR42 Recessed Pendent cULus cULus cULus RA1413 m FIFR42LL Recessed Pendent cULus,ULH cULus,ULH cULus,ULH RA1410 FIFR42XLH Recessed Pendent cULus cULus cULus RA1413 FIFR56 Recessed Pendent cULus,LPCB,VdS, cULus,FM,LPCB, cULus,VdS.EC,WM RA1414 EC,WM VdS,EC,WM FIFR56LL Recessed Pendent cULus,ULH cULus,ULH cULus,ULH RA1415 FIFR56 Recessed Horizontal Sidewall cULus cULus,FM cULus RA1435 4. 2 1/4'HOLE DA [57DnmJ - I I5/16'DIA [49.2mm) I L —_—= TURN COLLAR I Ti 1"X 1/2"REDUCER UNTIL TIGHT AGAINST SPRINKLER I WRENCH BOSS \ \ / FACE OF FITTING TO FACE OF CEILING DIMENSION l FI ESCUTCHEON p -----"".-'"=-- II AT MAXIMUM RECESS = I725.4mm] ���� �; AT MINIMUM RECESS = 3/879.SmmJ I LA Ff ESCUTCHEON F2 ESCUTCHEON 3/4719mm] �w' I AT MAXIMUM RECESS = 3/4719mm] c ADJUSTMENT 'I III 09.Va IIIII� '�,�' AT MINIMUM RECESS = 3/879.Smm] G. 12 ESCUTCHEON _ U) 1/2772.7mm] - '�J ' I`�''• �o 2 ADJUSTMENT f I`I :ji JI F1 ESCUTCHEON X ' 1 AT MAXIMUM RECESS = 7/8(22.2mmJ a •� �' [3 ] AT MINIMUM RECESS = 1-5/8741.3mm] two 1t1 �II ! F2 ESCUTCHEON `,1 ;�' AT MAXIMUM RECESS = 1-1/8-28.6mm) ... 40 AT MINIMUM RECESS = 1-5/8741.3mm] o 2 27/32.OM. Y [72.2mm3 m Fig. 1 w Model F1FR56, F1FR56LL, F1 FR42, F1 FR40, F1FR42LL, F1FRXLH & o F1 FR28 Recessed Pendent sprinkler with Model F1 or F2 escutcheon m` a a) rr- - =3� I I I 1"X 1/2" REDUCER :N 2 5/8" DL4. [66.7mm] HOLE IN CEILING 3 / N 2 5/16' DIA. (58.7mm] —I CUP w L == J a. CEILING - iii FACE OF FITTING LLI ..=— F ® � TO FACE OF CEILING 0 -.� IIIIII_�o _II•IIII !. DIMENSION '[\ !- AT MAXIMUM RECESS = 1-1/2738mm) N L��_ I ``j� 'fii4 AT MINIMUM RECESS = 1 25.4mm o `,;- �' AT MAXIMUM RECESS = 9/16[14.3mm] Y2T12.7mmj 411$ AT MINIMUM RECESS = 1[25.4mm] ADJUSTMENT I"! 3 1/4" DIA. f (82.6mm] Fig.2 Model F1FR56, F1FR56LL, F1FR42, F1FR40, F1FR42LL, F1FRXLH& F1 FR28 Recessed Pendent sprinkler with Model FP escutcheon 5. FACE OF FITTING TO FACE OF CEILING DIMENSION F1 ESCUTCHEON /iiiiiii//1 AT MAXIMUM RECESS = 1[25.4mm] / I AT MINIMUM RECESS = 3/8[9.5mm] Fl ESCUTCHEON F2 ESCUTCHEON ' AT MAXIMUM RECESS = 1-3/8[34.9mm] AT MAXIMUM RECESS = 3/4[19mm] `-•-- 7 AT MINIMUM RECESS = 2-1/1 6 7.52.4mm] AT MINIMUM RECESS = 3/8[9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8[41.3mm] 2 1/4" HOLE DIA. y I/8" AT MINIMUM RECESS = 2-1/16[52.4mm] [57.2mm] r...-[3.2mm] 1" X 1/2" REDUCER J -:IW f 1 I -� - (1) cu c 1 75/16" DIA. )n 1 II!I�iI�;IIIIIII �,ji. 4"-12" • x --- 1 101.6mm-304.8mm 1 (I)`a [49.2mm] I i I i'i IIllllllIIi --II 2 27/32" DIA. [ CEILING TO ] I J ` iy 1 /_�J [72.2mm] DEFLECTOR aI C TURN COLLAR UNTIL of TIGHT AGAINST SPRINKLER WRENCH BOSS. F1 ESCUTCHEON Y I F 3/4[I9mm] ADJUSTMENT —'I f2 ESCUTCHEON Y 1/2[12.7mm] ADJUSTMENT c6 emmw o RECESSED HSW W/F1 OR F2 ESCUTCHEON 0 (1) FM APPROVED FOR 4" - 6" [101.6MM - 152.4MM] CEILING TO DEFLECTOR WITH P2 ONLY. 0 Wi hi Fig. 3 a Model Fl FR56 Recessed Horizontal Sidewall sprinkler with Model F1 or F2 escutcheon a> as a 1" x 1/2" REDUCING TEE OR ELBOW �0 -'1.,..,__,_ a -- ----- 1--------+-------'fit------- - - ll - - - N — I ' 2 5/8" DIA. y 2 5/16" DIA — - HOLE IN CEILING _ a1 L , a a CUP Wk_—[� IL Li III[ syL�ll 1 1/2" MAX. ///, /;,r III: 11111 _,________To =' Ili21111 FACE OF FITTING 0 ////ri//AN "" FACE OF CEILING N �_t //,///// DIMENSION N CEILING � �\ 41 4(0, ////.../ft r ._- A;p /-.z� co 1/2" MAX. J - 15/16" COVER ADJUSTMENT COVER PLATE — ASSEMBLY f 3 5/16" DIA. - SPRINKLER CONCEALED, 1/2" ADJUSTMENT 017FGa1A Fig. 4 Model F1 FR56/F1 FR56LL Concealed Pendent sprinkler with standard depth 1/2-inch(12.7mm) adjustment- Model CCP cover plate 6. 1" x 1/2" REDUCING TEE OR ELBOW _. r 2 5/8"" DIA. 2 5/16"" DIA - HOLE IN CEILING L_— J CUP 1„ t\=.. 01.!1 I III�� 1 1/2"" MAX. r `.�— 'J FACE OF FITTING ----- 1 III III TO FACE OF CEILING „'' -'./ -7 kt i'� ':,,,,'::7 DIMENSION CEILING �`. //////// i E 5/16" MAX. 3/4 c COVER ADJUSTMENT Ti COVER PLATE— I } = ASSEMBLY 3 5/16" DIA. - / X SPRINKLER V c c ii CONCEALED, 5/16" ADJUSTMENT orsom v Fig. 5-Model F1 FR56/F1 FR56LL Concealed Pendent sprinkler with low profile 5/16- v inch (8.0mm)adjustment-Model CCP cover plate Maintenance Material Data Y The Model F1 FR Series sprinklers should be inspected and Frame: DZR Brass,QM Brass,or Low Lead Brass o the sprinkler system maintained in accordance with NFPA 25. o Do not clean sprinklers with soap and water, ammonia or any Deflector: CDA Alloy 220,260,or 510 'N other cleaning fluids.Remove dust by using a soft brush or gen- Load ScrewlPintle: CDA Alloy 360 or 544 > tie vacuuming. Replace any sprinkler which has been painted Cup: CDA Alloy 651 or 693 m (other than factory applied)or damaged in any way.A stock of Washer: Nickel Alloy 440 or 360,coaled with PTFE aspare sprinklers should be maintained to allow quick replace- Adhesive Tape c ment of damaged or operated sprinklers. Bulb: Glass 8 Finishes III(2) 2 Standard Finishes si m Sprinkler Escutcheon Cover plate Ordering Information 3 Bronze Brass Chrome Specify: a) Chrome Chrome White 1. Sprinkler Model: [F1 FR28][F1 FR40][F1 FR42] w White Polyester MP" White N Special Application Finishes [F1 FR42LL][F1 FRXLH][F1 FR56][F1 FR56LL] m co Sprinkler Escutcheon Cover plate 2. Sprinkler Deflector/Orientation: [Pendent][Recessed n. Electroless Nickel Electroless Nickel Bri h Pendent][Upright][Conventional][Horizontal Sidewall] PTFEt'>r4> PTFE g t Brass [R ecessed Recessed Horizontal Sidewall][Vertical Sidewall] Black Polyester t'>te>I'> Bright Brass Black z Bright Brass(5) Black Off White 3. Sprinkler threads: [1/2-inch NPT][ISO 7-R1/2] orOff Whitens)(' Off White Satin Chrome 4. Sprinkler Temperature Rating: [135°F (57°C)][155°F or Satin Chrome Satin Chrome (68°C)][175°F(79°C)][200°F(93°C)][286°F(141°C)] N r'>Other finishes and colors may be available on special order. Consult the 5. Sprinkler Finish 0 factory for details. al Paint or any other coating applied over the factory finish will void all approvals 6. Escutcheon Model: [F1][F2][FP] and warranties. 7. Escutcheon Finish(where applicable) p1 cULus Listed as Corrosion Resistant. 8. Cover Model:plate [standard wi FM Approved as Corrosion Resistant for SIN RA1414,RA1425,RA1435, profile CCP 1/2-inch and RA1485. (12.7mm) adjustment][low profile CCP 5/16-inch (5) 200°F(93°C)maximum temperature rated sprinkler only. (8.0mm)adjustment] er VdS Approved for RA1425,RA1414,RA1418,and RA1475. 9. Cover plate Temperature Rating: [135°F (57°C) for use m LPCB Approved for RA1425,RA1414,and RA1475. with Ordinary Temperature sprinklers][165°F (74°C) for use with Intermediate Temperature sprinklers] 10. Cover plate Finish Note:When Model F1 FR Series Recessed sprinklers are ordered,the sprin- klers and escutcheons are packaged separately. 7. Reliable. . . For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many pre- cision-made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Deluge valves • Flush automatic sprinklers • Detector check valves • Recessed automatic sprinklers • Check valves • • Concealed automatic sprinklers • Electrical system • Adjustable automatic sprinklers • Sprinkler emergency cabinets Y • Dry automatic sprinklers • Sprinkler wrenches 05. • Intermediate level sprinklers • Sprinkler escutcheons and guards • Open sprinklers • Inspectors test connections • • Spray nozzles • Sight drains • • Alarm valves • Ball drips and drum drips • • Retarding chambers • Control valve seals .65 • Dry pipe valves • Air maintenance devices • • Accelerators for dry pipe valves • Air compressors a • Mechanical sprinkler alarms • Pressure gauges 0 • Electrical sprinkler alarm switches • Identification signs • Water flow detectors • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of govemmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 100 years. Manufactured by Reliable Automatic Sprinkler Co.,Inc. Recycled p (800)431-1588 Sales Offices paper Reliable (800)848-6051(914)829-2042 Sales Fax Corporate Offices Revision lines indicate updated or new data. ec.Printed in U.S.A.12/21 P/N 9999970300 ww.reliablesprinkler.com Internet Address w Bulletin 044 March 2022 ® Model KFR-CCS Combustible Concealed Space Sprinkler cULus Listed Features • cULus Listed for areas of coverage up to 256 square feet q.. • Sprinkler may be installed on the same branch line that ^ supplies sprinklers below ceiling • Nominal K-factor of 5.6(80 metric) •t i" • Fusible link operating element ; • Quick response 212°F(100°C)fusible link operating element • • Standard brass finish •7 Product Description Reliable's Model KFR-CCS Combustible Concealed Space Sprinkler is a quick response,upright,special sprinkler designed to provide protection of specific light hazard combustible and noncombustible concealed spaces requiring sprinkler protection. The KFR-CCS sprinkler is specifically listed for the protection of shallow combustible concealed spaces described in NFPA 13. The Model KFR-CCS Sprinkler utilizes a fast response solder aanaillige# - link fusible element that has demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers.This feature enables the sprinkler to apply water to a fire much faster than standard response sprinklers of the same temperature rating. Model W2 Wrench Application Maintenance The Model KFR-CCS sprinkler is specifically listed for use Model KFR-CCS Sprinklers should be inspected and maintained in horizontal combustible concealed spaces with a slope in accordance with the applicable version of NFPA 25. Do not not exceeding 2:12 with combustible wood truss,wood joist clean sprinklers with soap and water,ammonia or any other construction,or bar joist construction having a combustible upper cleaning fluids.Remove dust by using compressed air or by surface and where the depth of the space is less than 36"(914 vacuuming,provided equipment does not touch the sprinkler. mm)from deck to deck,from deck to ceiling,or with double wood Replace any sprinkler which has been painted(other than factory joist construction with a maximum of 36"(914 mm)between the applied)or damaged in any way.A stock of spare sprinklers top of the bottom joist and the bottom of the upper joist. NFPA should be maintained to allow quick replacement of damaged 13 permits the use of the Model KFR-CCS sprinkler(a)where or operated sprinklers. Prior to installation,sprinklers should be the space is less than 12"(305 mm)from deck to deck or deck maintained in the original cartons and packaging to minimize the to ceiling,and/or(b)where a portion of the protected space potential for damage to sprinklers that would cause improper exceeds 36"(914 mm). operation or non-operation. Installation Guarantee Model KFR-CCS Sprinklers are to be installed in the upright For Reliable Automatic Sprinkler Co., Inc. guarantee, terms, and position with their frames arms parallel to the pipe(Refer to Figs. conditions,visit www.reliablesprinkler.com. 4 through 9). When installing the Model KFR-CCS sprinkler use only the Reliable Model W2 installation wrench. Usage of any Ordering Information other type of installation wrench may damage the sprinkler and will immediately void the manufacture's warranty. Specify: Model KFR-CCS Sprinkler Note:A leak tight h"NPT(R1/2)sprinkler joint can be obtained with an installation torque of approximately 8-18 ft-lbs(10.8— 24.4 N-m).Do not tighten sprinklers over these recommended limits,Doing so may cause leakage and/or premature operation. www.reliablesprinkler.com r Model KFR-CCS Combustible Concealed Space Upright Sprinkler SIN RA4454 Finish Technical Specifications Standard Brass Style:Upright Threads:1/2"NPT or JSO7-1R1/2 <..... Nominal K-Factor:5.6(80 metric) Temperature Ratings ,, 1 ' 212°F(100°C) . 'ii Max.Working Pressure:175 psi(12 bar) ��' ra Sensitivity I 7 Material Specifications Thermal Sensor:Nickel Alloy Fast Response , Sprinkler Frame:Brass Alloy 5 ,i Sprinkler Wrench �, Button:Copper Alloy • Model W2 Sealing Assembly:Nickel Alloy with PTFE Load Screw:Bronze Alloy Approvals ; ' Deflector:Bronze Alloyv. cULus Listed .... �'l' Model KFR-CCS Components and Installation Dimensions Figure 1 ` 1-21/32" DEFLECTOR I ' (42 mm) 1 Iiul►� COMPRESSION SCREW �i I 1� ,11' (Si,It- lt * II_' ` FUSIBLE LINK Ili 1 -lII11, `AmL,�1��--11 �/ I,Ir1 i'� SEALING ASSEMBLY I is (571/4) �`IIII 11111 " . -0111 iiii WRENCH FLATS - FRAME I - -_- I I i COMPONENTS DIMENSIONS Model KFR-CCS General Application Criteria Minimum Distance(Spacing)Between Sprinklers 6'(1.83m) Note:This minimum spacing does not apply to any additional sprinklers that are required for protection of CPVC piping that is offset over an obstruction(refer to figures 4 and 5). Maximum Distance(Spacing)Between Sprinklers 14'(4.27 m)for solid wood and composite wood joist construction.For wood truss or bar joist construction, 14'(4.27 m)for concealed spaces that are less than 18"(457 mm)in depth; 16'(4.88 m)for concealed spaces that are 18"(457 mm)or more in depth. Maximum Coverage Area Per Sprinkler 196 ft2(18.2 m2)for solid wood or composite wood joist construction.For wood truss or bar joist construction, 196 ft2(18.2 m2)for concealed spaces that are less than 18"(457 mm)in depth;256 ft2(23.8 m2)for concealed spaces that are 18"(457 mm)or more in depth. Note:Sprinkler spacing,and therefore coverage area, is determined by the depth of the concealed space. When transitions occur in the concealed space,the sprinklers may immediately be spaced at the largest approved coverage area per the above listings for the concealed space depth(refer to Fig.2). Obstruction Rules All obstruction criteria per the applicable version of the NFPA 13 apply unless modified by this bulletin(refer to Fig.3). The KFR-CCS is classified as an Extended Coverage Upright Spray Sprinkler where the maximum coverage area per sprinkler exceeds 225 ft2(20.9 m2). The KFR-CCS is classified as a Standard Upright Spray Sprinkler where the maximum coverage area per sprinkler is 225 ft2(20.9 m2)or less. Bulletin 044 Page 2 of 9 March 2022 MIME www.reliablesprinkler.com Model KFR-CCS Sprinkler Spacing at Change in Concealed Space Depth Figure 2 XFR-CCS SPRWXIER UPPER OEOX II "11111" 6' 5TM m] Imo■ ' I 1 ' 45 OR GREATER SEE NOTE I M.. II______ 2'-O MNX M IMUI SPACXG WARM SPACING 14'X 14'[4.3 m �X 4.3 a] / N-- m 16'X 16'[4.9 X 4.9 m] mt.. 19E SE DR2 rej 256 sF[2x9 m'J Note I:Fur eloping concealed spaces,Erect punt between epdnmer spacings iv the point where the depth au the space equals 16'[457 men]. Bulletin 044 Page 3 of 9 March 2022 'Reliable www.reliablesprinkler.com Model KFR-CCS Specific Application Obstruction Criteria Figure 3 DISTANCE FROM CENTERLINE MAXIMUM ALLOWABLE OF SPRINKLER TO SIOE OF DISTANCE OF DEFLECTOR OBSTRUCTION. ABOVE BOTTOM OF UPPER DECK OR BOTTOM OF DIMENSION'A" OBSTRUCTION. NONCOMBUSTIBLE INSULATION DIMENSION'B' - L ff OBSTRUCTION Cl? m KFR-CCS 10,5511 12 TO OfI I30Bmm TO<45]mml 5M�1 IIII'F SPRINKLER Ia To<24, 5y y 'A' 14515wn TO<5105551 IBBmmJ 26'TO C . 5,5• IBlumn TO 5152mfI I14051nl 30•TO 538. 1.5' NOTE: 1162mm TO<BNmmj I191mm1 SPRINKLER DEFLECTOR MUST BE AT OR BELOW THE BOTTOM a.TO 5,12. 9.5' OF THE TOP CHORD OF THE TRUSS. I314mm TO<105115m1 12610551 02TO<43' 12' OTHER WEB MEMBERS AND GUSSETS SHALL NOT BE [1061mm TO<1219mm1 Pcsmm] CONSIDERED OBSTRUCTIONS PROVIDED THE MINIMUM 4-1/2' 4Y TO<54' 10' LATERAL DISTANCE(FIG.4,6,&8)REQUIRED BY THE SPECIFIC 11215mm TO<13721m1 I35emml APPLICATION LISTING IS MAINTAINED. 50'TO<50' 16s ���\�® 113T2mn TO<1526mm I6] 1emm1 UPPER DECK OBSTRUCTION rr KFR-CCS OBSTRUCTION SPRINKLER KFR-CCS ,C, SPRINKLER '� k���LOWER DECK .A1 .Dr L ELEVATION VIEW PLAN VIEW Az3C OR 3D(USE DIMENSION C OR 0,WHICHEVER IS GREATER) MAXIMUM CLEAR DISTANCE REQUIRED 15 24 IN.(610 mm) MINIMUM HORIZONTAL DISTANCE VERTICAL DISTANCE DIMENSION"A" BELOW DEFLECTOR --'A'�I DIMENSION'S• L I UPPER DECK m 2 I5152n511 115rnrn1 'B' i >5•Toa 4' ::: I>152mn To 228mm1 I.02mmI KFR-COS SPRINKLER >B'TO I2 5' I>229nnm TO 30551511 1152mm1 OBSTRUCTION 512TO 15' B' 15305mm TO 381mm1 120351ml LOWER DECK >u'TD 18' gg I5.35I5151 TO 057mm] 1241mml 518'TO24' 12.5' 15457mm TO Biorml 1318m151 >24'T030' 15.5' I>51amn TO 702rm1 1394nm1 >30' 15' I5152n551 145751m1 044F003n Bulletin 044 Page 4 of 9 March 2022 Reliable www.reliablesprinkler.com Model KFR-CCS Specific Application Criteria for CPVC Pipe Sprinkler Systems When used with CPVC piping,the Model KFR-CCS Sprinkler is Minimum Distance Away From Face of Wood Truss or Top specifically listed to provide protection of combustible concealed Chord of Bar Joist spaces where the construction methods consist of: 4.5 in.(114 mm)(Refer to Fig. 3) 1. Wood trusses or wood bar joist(Refer to Fig.4) 2. Noncombustible insulation-filled solid wood or composite Deflector Position wood joists*(Refer to Fig.5) At or below the bottom of the top chord; 1.5 in.(38 mm)minimum to 4 in.(102mm)maximum below upper deck(or insulation if *Note:In order to be considered"noncombustible insula- present)for wood truss construction or wood bar joist construc- tion-filled,solid wood or composite wood joists"construction,the tion(Fig.4). insulation(including insulation provided with a combustible vapor 1.5 in.(38 mm)minimum to 4 in. (102mm)maximum below barrier),must completely fill the pockets between the joists to the bottom of the joists.Insulation installed above the elevation bottom of insulation for noncombustible insulation-filled solid or of Model KFR-CCS sprinklers in wood truss,solid wood joist or composite joist construction(Fig.5). composite wood joist must be secured into place with metal wire Hydraulic Design Area netting.The metal wire netting is intended to hold the insulation in Calculate all sprinklers within the draft curtain area,up place should the insulation become wet by the operation of Model to the 1,000 ft2(93 m2)maximum draft curtain area. KFR-CCS Sprinklers in the event of a fire. Note:Additional sprinklers that are required for protection of CPVC piping that is offset over an obstruction do not need to be In order to use the CPVC pipe and fittings,the horizontal runs of included in the remote area. pipe must be a maximum of 6 in.(152 mm)above the ceiling or noncombustible ceiling insulation,or 1/3 the depth of concealed Required Density space(as measured from the top surface of the ceiling to the 0.10 ftz(4.08 Lpm/m') bottom of the deck above),whichever is smaller(Refer to Figs.4 &5). Minimum Operating Pressure The CPVC piping can be used to supply the Model KFR-CCS 7 psi(0.48 bar) Sprinklers as well as sprinklers installed below the ceiling.Unless modified by this technical data sheet,all guidelines provided by the CPVC pipe and fitting manufacturer must be followed. When using 1 in.(DN25)or larger pipe,a hanger must be located at the truss nearest a sprig for purposes of restraint.If using 3/4 in.(DN19)piping,all sprigs over 12 in. (305 mm)must be laterally braced using methods described in the NFPA standards. Where the CPVC must be offset up and over an obstruction and the pipe exceeds the allowed horizontal positioning requirements specified above as well as shown in Figs.4 and 5,additional Mod- el KFR-CCS Sprinklers are to be installed to protect the CPVC products.A minimum lateral distance of 18 in.(457 mm)must be maintained between the CPVC pipe and heat pumps,fan motors, and heat lamps. Concealed Space Area The area of the concealed space is not limited;however,for both Figs.4 and Fig.5 where CPVC pipe is being utilized,draft-cur- tains or full height walls must be provided at 1,000 ftz(93 m2) maximum areas.This draft curtain shall be at least 1/3 the depth of the concealed space or 8 in.(203 mm),whichever is greater, and be constructed using a material that will not allow heat to escape through or above the draft curtain. System Type Light hazard,wet pipe system. Bulletin 044 Page 5 of 9 March 2022 a is www.reliablesprinkler.com Model KFR-CCS CPVC Pipe Figure 4` ' CPVC PIPE CONSTRUCTION: WOOD TRUSS OR WOOD BAR JOIST TOP CHORD DEPTH 4' 4-1/2'[114mm)MINIMUM FROM (100 mm)OR LESS CENTERLINE OF SPRINKLER TO bursas m FACE OF WOOD TRUSS OR UPPER TOP CHORD OF BAR JOIST DECK SEE NOTE 1 --.\ \ l=plith, WKIMUM i I oon iii mu LUI SEE NOTE 2 r iiiMM I KFR-CCS SPRINKLERS TO BE I I INSTALLED WITH FRAME ARMS _ ' '„ I IN-LINE(PARALLEL)WITH PIPE I -J ADSYHIICHOB:: ilmmomit-■'.-I ,.mom CEILING . �I�S fit [PIPE SHALL BE LOCATED A MAXIMUM OF 6'ABOVE THE TOP OF THE WHEN OFFSETTING CPVC PIPE OVER CEILING(OR INSULATION),OR A MAPAUM OF ONE-THIRD(I/3)THE OBSTRUCTION,A KFR-CCS SPRINKLER RUST BE DEPTH OF THE CONCEALED SPACE ABOVE THE TOP OF THE CEIUNG. INSTALLED DIRECTLY ON THE PIPE OVER THE WHICHEVER IS SMALLER. OBSTRUCTION. Note 1:Deflector at or below bottom of top chard; I-1/2'(38 mm)minimum to 4'(102 mm)maximum below bottom of roof deck or insulation. Note 2:Distance evaluated os pad of taus Luting: 12'to 36'(305 to 914 mm). NFPA 13 permits the installation of three,rinklers in Combustible concealed spaces where(a)the distance from deck to deck or deck to ceiling is less than 12'(305 mm)and/or(b)a portion of the protected moo exceeds a depth of 36'(914 men). Model KFR-CCS CPVC Pipe Figure 5 CPVC PIPE COh'STRJCTON: NONCOMBUSTIBLE INSUATON-FILLED SOLID WOOD OR COMPOSITE WOOD JOIST Dwmm oe UPPER NONCOMBUSTIBLE SOLID WOOD COMPOSITE WOOD DECK INSULATION JOISTS JOISTS �1 MAXIMUM SEE NOTE 3 SEE NOTE 1 Xx _ I 6'[152mm) r SEE NOTE 2 r KFR-CCS SPRINKLERS TO BE � �'_•, I INSTALLED WITH FRAME ARMS I ■ LIN-LINE(PARALLEL)WITH PIPE] OBSYNUCYNIR I -.-I , ,....` ,� CaUNG ow tIlls ex. Is. tIll PIPE SHALL BE LOCATED A MAXIMUM OF 6"ABOVE WHEN OFFSETTING CFVC PIPE OVER THE TOP OF THE COUNG(OR INSLNATION),OR A OBSTRUCTKNL A KFR-CCS NOIMUM OF ONE-THIRD(1/3)THE DEPTH OF SPRINKLER MUST BE INSTALLED THE CONCEALED SPACE ABOVE THE TOP OF 111E DIRECTLY ON THE PIPE OVER THE CERING,WHICHEVER IS SMALLER. OBSTRUCTION. Note 1:Deflector diction below bottom ofjoist/insulation to be I-I/O to 4'(38 mm to 102 mm). Note 2:Distance evaluated on pad of nULus Luting: 6'to 36'(152 to 914 mm).NFPA 13 permits the installation of these sprinklers in combustible concealed spaces where a portion of the protected area emceed,o depth of 35'(914 mm). Note 3:Maximum distance enoluoted as pad of mULus Luting:60'(1524 mm). Bulletin 044 Page 6 of 9 March 2022 llellabig www.reliablesprinkler.com Model KFR-CCS Specific Application Criteria for Steel Pipe Systems When used with steel piping,the Model KFR-CCS Sprinkler is System Type specifically listed to provide protection of combustible concealed Light hazard,wet or dry pipe system. areas where the construction methods consist of: 1. Wood trusses or wood bar joists(Refer to Fig.6) Deflector Position 2. Solid wood joist construction where the upper ceiling joists At or below the bottom of the top chord; 1.5 in.(38 mm) may have a maximum depth of 12 in.(305 mm).(Refer to minimum to 4 in. (102mm)maximum below upper deck(or Fig.7). insulation if present)for wood truss construction or wood bar joist 3. Noncombustible insulation-filled,solid wood or composite construction(Fig.6). wood joists*(Refer to Fig.9) 1.5 in.(38 mm)minimum to 2 in.(51 mm)maximum below the 4. Obstructed wood trusses;top chord more than 4"deep bottom of the top chord for spaces constructed of obstructed (Refer to Fig.8). wood trusses(Fig.8). *Note:In order to be considered"noncombustible insulation- 1.5 in.(38 mm)minimum to 2 in.(51 mm)maximum below the filled,solid wood or composite wood joists"construction,the bottom of the upper joist for concealed spaces constructed of insulation(including insulation provided with a combustible vapor exposed solid wood joists(Fig 7). barrier),must completely fill the pockets between the joists to 1.5 in.(38 mm)minimum to 4 in.(102mm)maximum below the bottom of the joists.Insulation installed above the elevation of Model KFR-CCS sprinklers in wood truss,solid wood joist or bottom of insulation for noncombustible insulation-filled solid or composite wood joist must be secured into place with metal wire composite joist construction(Fig.9). netting. The metal wire netting is intended to hold the insulation Minimum Distance Away From Face of Wood Truss or Top in place should the insulation become wet by the operation of Chord of Bar Joist Model KFR-CCS Sprinklers in the event of a fire. 4.5 in.(114 mm)(Refer to Fig.4) Concealed Space Area Hydraulic Design Area The area of the concealed space is not limited;however,for For wood truss construction(Fig.6),solid wood joist construction wood truss construction or concealed spaces of noncombustible (Fig.7),or obstructed wood truss construction(Fig.8),calculate bar joist construction(Refer to Fig.6)draft-curtains or full height all sprinklers within the draft curtain area,up to the 1,000 ft2 walls must be provided at 1,000 ft2(93 m2)areas.The draft (93 m2)maximum draft curtain area for both wet and dry pipe curtain shall be at least 1/3 the depth of the concealed space or systems. 8 in.(203 mm),whichever is greater,and be constructed using a material that will not allow heat to escape through or above the For noncombustible insulation-filled solid wood joist or composite draft curtain. wood joist construction(Fig.9)where draft curtains are not required,calculate per the requirements of NFPA 13. For solid wood joist construction(Refer to Fig.7)and obstructed wood truss construction(Refer to Fig.8),blocking must be provided in each joist or top chord channel at maximum 32 ft. Required Density (9.75 m)intervals.This blocking shall be installed to the full 0.10 gpm/ft2(4.08 Lpm/m2) depth of the joist or top chord and be installed so as to not allow heat to escape through or above the blocking.The blocking Minimum Operating Pressure must be constructed using a noncombustible material or be of 7 psi(0.48 bar) the same material as the joist or truss member. Draft curtains must be protrude below the joist a minimum of 6 in.(152 mm) or 1/3 the space,whichever is greatest and run parallel with the joist spaced at 31 ft.(9.45 m)width maximum to limit the area to a maximum of 1,000 ft2(93 m2).The draft curtain may be constructed of i4 in.(6.4 m)plywood to prevent heat from escaping beyond the area. For noncombustible insulation-filled,solid wood joist or composite wood joist construction(Refer to Fig.9),the requirement for draft curtains or blocking does not apply. Bulletin 044 March 2022 Reliabir Page 7 of 9 www.relic tiles prin kl er.com Model KFR-CCS Steel Pipe Figure 6 STEEL PIPE CONSTRUCTION: WOOD TRUSS OR WOOD BAR JOIST(TOP CHORD 4'OR LESS IN DEPTH) owraw_as FROM FACE OF WOOD TRUSS OR TOP WOOD TRUSS OF CHORD OF BAR JOIST OR BAR JOIST 4.5'(114mm]MINIMUM DISTANCE UPPER DECK . . . I MIMIIIIIIIMMIIIMIIMIMORIMIMIOL i r KFR-CCS SPRINKLERS 1O BE I INSTALLED WITH FRAME ARMS I SEE NOTE 2 LIN-UNE(PARALLEL)WITH PIPEJ LOCATION OF STEEL PIPE IN CONCEALED SPACE IS NOT RESTRICTED CEILING 1. me PI • Note 1:Deflector of or below the bottom of the top chord; 1-1/2'(38 mm)to 4'(102 mm)below bottom of roof deck or insulation. Note 2:Distance evaluated as port of CULos Listing: 12"to 36'(305 to 914 mm). NFPA 13 permits the installation of these sprinklers in combustible conceded spaces where(o)the datonce from deck to deck or deck to ceiling is less than 12'(305 nwn) and/or(b)a portion of the protected area exceeds a depth of 36" (914 mm). Model KFR-CCS Steel Pipe Figure 7 STEEL PIPE CONSTRUCTOR: SOUD WOOD JOIST OIRCNLD] //—UPPER SOL<\ODXf6'[40G\ON CEFI ,.....it,,,,,,,,,,,.....,,!„ ...\...,,.,�.\i/ .„„r. \'K 1 \ N NN II`. \ 12'MAXIMUM[305mm] SEE NOTE 2 f \ XFR-CCS \ N FOR MAXIMUM xSPRINKIER DISTANCE SEE NOTE 1 P MINIMUM DISTANCE FOR MINIMUM - T ALL SPRINKLERS TO BE , 1.5"[3Bmm) 111 AND MAXIMUMMAXIMUM DISTANCE DISTANCE INSTALLED WITH I I FRAME ARMS N-UNE WITH THE I 2"[51mm] LRUN OF THE PIPE.(PARALLLLEEEI)) CEILING FRAMING CEILING Note 1:Minimum to Maximum Distance evaluated as part of cULus Listing; 6'to 36'(152 to 914 mm). NFPA 13 also permits the installation al these sprinklers in combustible concealed spaces where(1)the distance from deck to deck or deck to ceiling is less Than 12'(305 mm)or(2)o portion of the protected area exceeds a depth of 36'(914 mm). Note 2:Maximum Distonce evaluated os port of cULus Listing:54-(1372 mm). NFPA 13 also permits the installation of these sprinklers in combustible conceded spaces where(1)the distmrce from deck to deck or deck to ceiling is less than 12'(305 rem)or(2)a portion of the protected area exceeds a depth of 36-(914 mm). Bulletin 044 Page B of 9 March 2022 Reliable www.reliablesprinkler.com Model KFR-CCS Steel Pipe Figure 8 STEEL PIPE CONSTRUCTION: OBSTRUCTED WOOD TRUSS OR BAR JOIST (TOP CHORD MORE THAN 4 IN. DEPTH) D44FCa4_a9 WOOD TRUSS OR BAR JOIST UPPER DECK SEE NOTE 3 � iiiiii SEE NOTE 1 SEE NOTE 2 ' KNSTALLED WTH KLERSFRAM TO BE I LOCATION OF STPIPE IN CONCEA I IN-LINE (PARALLEL) WITH PIPE.J SPACE IS NOT RESTRICTED gi -4 Rio SI SI l� CEILING Note 1: Deflector distance below bottom of joist to be 1-1/2" to 2" (38 mm to 51 mm). Note 2: Distance evaluated as part of cULus Listing: 6" to 36"(152 to 914 rum). NFPA 13 also permits the installation of these sprinklers in combustible concealed spaces where a portion of the protected area exceeds o depth of 36" (914 mm). Note 3: Maximum distance evaluated os port of cULus Listing: 60" (1524 mm). Model KFR-CCS Steel Pipe Figure 9 STEEL PIPE CONSTRUCTBN: NONCOMBUSTIBLE INSULATION-nLLED SCUD WOOD OR COMPOSITE WOOD JOIST wucw-w NONCOMBUSTIBLE soup WOOD �COMPOSRE WOOD UPPER INSULATION JOISTS JOISTS DECK \ \\ \ E \ ISEE NOTE 3 SEE NOTE 2 y SEE NOTE 1 r KFR-CCS SPRINKLERS TO BE 1 LOCATION OF STEEL I INSTALLED WITH FRAME ARMS I PIPE IN CONCEALED [W-LINE(PARALLEL)WITH PPE.J SPACE R ESTRICT ISED NOT CEILING 0) Nate 1: Deflector distance below bottom of joist/insulation to be 1-1/2"to 4"(39 mm to 102 mm). 0V N- Note 2:Distance evaluated as pod of cULus Listing: 6"to 36"(152 to 914 mm).NFPA 13 permits the installation of these CD sprinklers in combustible conceded spaces where a portion of the protected area exceeds a depth of 36"(914 mm). rd) Note 3:Maximum distance molested as part of cULus listing: 60"(1524 mm). ad Z a Bulletin 044 March 2022 ReliabNg Page 9 of 9 www.reliablesprinkler.com Bulletin 935 March 2022 ... Model KRes Series Fusible Link Reliabld Residential Sprinklers For NFPA 13,NFPA 13R,and NFPA 13D Applications cULus Listed Features • cULus Listed Residential Sprinklers , • Available in pendent and horizontal sidewall orientations .. • Decorative recessed escutcheons available - 'J .. a z Product Description Model KRes Series sprinklers are residential pendent and horizontal sidewall sprinklers with a fusible link operating element. KRes30 Recessed Pendent KRes49 Recessed Pendent A variety of K-Factors and recessed finish options are available as detailed in this Bulletin. The KRes Series sprinklers are specially engineered for fast thermal response to meet the requirements of UL 1626.They are intended for installation in accordance with NFPA 13, 13R,and . (r; ,' ,. 13D. �� Application . • The Model KRes Series sprinklers cULus Listed Residential KRes58 Recessed Pendent KRes44 HSW Recessed sprinklers are intended for use in accordance with NFPA 13,NFPA 13R,or NFPA 13D.The Model KRes residential Horizontal Sidewall sprinklers are cULus Listed for use in residential occupancies and residential portions of any occupancy,where permitted by NFPA 13, NFPA 13R,or NFPA 13D.For NFPA 13R and NFPA 13D applications,the design flow and pressure shall not be less than the minimum flow and pressure specified in the Listed Design Criteria tables in this Bulletin.For NFPA 13 applications, the design density shall be a minimum of 0.1 gpm/sf(4.1 mm/ ,, , min),but in no case shall the flow and pressure be less than the minimum flow and pressure specified in the Listed Design Criteria tables in this bulletin.Model KRes Series sprinklers are listed for use in wet systems only. KRes58 HSW Recessed KRes58 HSWX Recessed Horizontal Sidewall Horizontal Sidewall Residential Sprinkler Summary Table A Sprinkler Sprinkler K-Factor Model Identification Orientation gpm/psi'n Thread Size Installation Options -Max.Coverage Area ft Number(SIN) (Ipm/bar") NPT or1507-i x ft(m x m) KRes30 R3591 Pendent 3.0(43) 1/2 Pendent or Recessed 16 x16(4.9 x 4.9) KRes49 R3596 Pendent 4.9(71) 1/2 Pendent or Recessed 20 x 20(6.1 x 6.1) KRes58 R3593 Pendent 5.8(84) 1/2 Pendent or Recessed 20 x 20(6.1 x 6.1) KRes44 HSW RA3591 Horizontal Sidewall 4.4(63) 1/2 Sidewall or Recessed 16 x 20(4.9 x 6.1) KRes58 HSW RA3503 Horizontal Sidewall 5.8(84) 1/2 Sidewall or Recessed 16 x 20(4.9 x 6.1) KRes 58 HSWX RA3593 Horizontal Sidewall 5.8(84) 1/2 Sidewall or Recessed 14 x 26(4.3 x 7.9) www.reliablesprinkler.com Model KRes30 SIN R3591 Technical Specifications Finishes Style:Pendent (See Table H) Threads: 1/2"NPT or ISO7-1R1/2 Sensitivity Nominal K-Factor:3.0(43 metric) -.., Max.Working Pressure: 175 psi(12 bar) Fast-response -^:. Temperature Ratings 165°F(74°C) d Material Specifications(Ref.Fig.7) 212°F(100°C) Thermal Sensor:Nickel Alloy fusible link Recessed Escutcheons Sprinkler Frame:Brass Alloy F2 Recessed __" Button:Copper Alloy Sprinkler Wrenches Sealing Assembly:Nickel Alloy with PTFE Model W2 Load Screw:Bronze Alloy Model W1 (recessed) Deflector:Bronze Alloy Listings and Approvals Lever:Stainless Steel cULus Strut:Stainless Steel Model KRes30 Sprinkler Drop Figure 1 2-1/4"(57mm) DIA. Face fittingof to finished ceiling 1-15/16° 3/8"(9mm)+/- (49mm)DIA. 1/4"(6mm) I a 2-„4• i aid; . (57mm) m S; m4i.= h Irr IIr `` w r II� �," 1-1/2"(38mm)+/- I •n. `t(, .n, lo/ 1/4"(6mm) [.._ 1-1/8" 2-7/8"(72mm)DIA. (28mm) Dimensions F2 Recessed Escutcheon Installation Model KRes30 Sprinkler Hydraulic Design Criteria - Minimum Flow and Residual Pressure Max.Coverage Area Flow GPM Pressure ft.x ft(m x m) (Llmin) PSI(bar) Deflector to Ceiling Distance 12 x 12(3.6 x 3.6) 8(30.3) 7(0.48) General 1 to 4 inches (25 to 100mm) 14 x 14(4.3 x 4.3) 10(37.8) 11 (0.76) F2 Escutcheon 1-1/4 to 1-3/4 inches 16 x 16(4.9 x 4.9) 13(49) 18.8(1.3) (31.7 to 44.4 mm) Bulletin 935 Page 2 of 9 March 2022 Reliable www.reliablesprinkler.com Model KRes49 SIN R3596 29 Technical Specifications Finishes Style:Pendent (See Table H) Threads:1/2"NPT or IS07-1R1/2 Sensitivity Nominal K-Factor:4.9(71 metric) Fast-response " Max.Working Pressure:175 psi(12 bar) Temperature Ratings ': 165°F(74°C) !" "` Material Specifications(Ref.Fig.7) 212°F(100°C) Thermal Sensor:Nickel Alloy fusible link Recessed Escutcheons Sprinkler Frame:Brass Alloy F2 Recessed #` Button:Copper Alloy Sprinkler Wrenches i Sealing Assembly:Nickel Alloy with PTFE Model W2 ( Load Screw:Bronze Alloy Model W1 (recessed) Deflector:Bronze Alloy Listings and Approvals Lever:Stainless Steel cULus Strut:Stainless Steel Model KRes49 Sprinkler Drop r 2-1/4"(57mm) DIA. Face of fitting to finished ceiling 1-15/16" 3/8"(9mm)+/- (49mm)DIA. 1/4'(6mm) L:.. jffiA =WElir li�� _ 4 1- (57mm) I Not=� III �� )II ,��:: �' ��l .n. �/ 1-1/1/4"(6mm) `Q�u � `,�iui/ 1 1-1/4' 2-7/8'(72mm)DIA.— (32mm) Dimensions F2 Recessed Escutcheon Installation Model KRes49 Sprinkler Hydraulic Design Criteria Table C Minimum Flow and Residual Pressure Ordinary Temp.Rating Intermediate Temp.Rating Max.Coverage Area (165FJ74°C) (21rF1100°C) Deflector to ft.x ft.(m x m) Flow Pressure Flow Pressure Ceiling Distance GPM(Umin) PSI(bar) GPM(Umin) PSI(bar) 12 x 12(3.6 x 3.6) 13(49) 7(0.48) 13(49) 7(0.48) General 1 to 4 inches 14 x 14(4.3 x 4.3) 13(49) 7(0.48) 13(49) 7(0.48) (25 to 100mm) 16 x 16(4.9 x 4.9) 13(49) 7(0.48) 15(56.8) 9.4(0.65) F2 Escutcheon 1-1/4 to 1-3/4 inches 18 x 18(5.5 x 5.5) 17(64.3) 12.0(0.83) 17(64.3) 12.0(0.83) (31.7 to 44.4 mm) 20 x 20(6.1 x 6.1) 20(75.7) 16.7(1.14) 22(83.3) 20.2(1.39) Bulletin 935 Page 3 of 9 March 2022 Oilellablg www.reliablesprinklercom Model KRes58 SIN R3593 Technical Specifications Finishes Style:Pendent (See Table H) Threads:1/2"NPTorISO7-1R1/2 Sensitivity Nominal K-Factor:5.8(84 metric) Fast-response Max.Working Pressure:175 psi(12 bar) �_, Temperature Ratings 165°F(74°C) Material Specifications(Ref.Fig.7) 212°F(100°C) Thermal Sensor:Nickel Alloy fusible link Recessed Escutcheons Sprinkler Frame:Brass Alloy F2 Recessed Button:Copper Alloy Sprinkler Wrenches Sealing Assembly:Nickel Alloy with PTFE Model W2 Load Screw:Bronze Alloy Model W 1 (recessed) Deflector:Bronze Alloy Listings and Approvals Lever:Stainless Steel cULus '' Strut:Stainless Steel Model KRes58 Sprinkler Drop Figure 3 2-1/4"(57mm) _ DIA. Face of fitting to finished ceiling 1-15/16" 3/8"(9mm)+/- (49mm)DIA. 1/4"(6mm) � I 2-1/4" ill;r A 1111 -1.il A j II)(57mm) `r�`" )1 1-1/2"(38mm)+/- ;t Al %i) 1/4"(6mm) 4.11110 1-1/4" 2-7/8"(72mm)DIA. - (32mm)y Dimensions F2 Recessed Escutcheon Installation Model KRes58 Sprinkler Hydraulic Design Criteria Table D'- Minimum Flow and Residual Pressure 1 Ordinary Intermediate Max.Coverage Area Temp.Rating Temp.Rating (165°F/74°C) (212°F/100°C) Deflector to ft.x ft.(m x m) Ceiling Distance Flow Pressure Flow Pressure GPM(Umin) PSI(bar) GPM(L/min) PSI (bar) 12 x 12(3.6 x 3.6) 16(61) 7.6(0.53) 16(61) 7.6(0.53) General 1 to 4 inches 14 x 14(4.3 x 4.3) 16(61) 7.6(0.53) 16(61) 7.6(0.53) (25 to 100mm) 16 x 16(4.9 x 4.9) 16(61) 7.6(0.53) 17(64.3) 8.6(0.59) F2 Escutcheon 18 x 18(5.5 x 5.5) 19(72) 10.8(0.75) 19(72) 10.8(0.75) 1-1/4 to 1-3/4 inches 20 x 20(6.1 x 6.1) 22(83.3) 14.4(1.0) 23(87.1) 15.7 (1.08) (31.7 to 44.4 mm) Bulletin 935 Page 4 of 9 March 2022 Reliable www.reliablesprinkler.com Model KRes44 HSW : SIN RA3591 Technical Specifications Finishes Style:Horizontal Sidewall (See Table H) Threads:1/2"NPT or IS07-1 R1/2 Sensitivity Nominal K-Factor:4.4(63 metric) Fast-response Max.Working Pressure:175 psi(12 bar) Temperature Ratings 165°F(74°C) Material Specifications(Ref.Fig.7) Recessed Escutcheons Thermal Sensor:Nickel Alloy fusible link F2 Recessed Sprinkler Frame:Brass Alloy Sprinkler Wrenches °' Button:Copper Alloy Model W2 Sealing Assembly:Nickel Alloy with PTFE Model W1 (recessed) Load Screw:Bronze Alloy Deflector:Bronze Alloy Listings and Approvals Lever:Stainless Steel cULus Strut:Stainless Steel Model KRes44 HSW/F2 Figure 4 1-3/4"(44mm) Face of tilting 3/8"(9mm) */-1/4"(Bmm) to finished wall +/-1/4'(6mm) 11% 2-1/2"(64mm) _� 1 III II . UM MI Top of Deflector Down from IIIIIhIIIIIPE�/ II J (SDIA. ) (4DIAm) Ie00b 150miling to be mf)or6'to 67 BPI' (150 to 300 mm)Based on U5/16" II Flow 8 Pressure Selection (8mm) lour I Dimensions F2 Recessed Escutcheon Installation Model KRes44 HSW/F2 Sprinkler Hydraulic Design Criteria Table E Minimum Flow and Residual Pressure Ordinary Temp.Rating Max.Coverage Area (165°F/74°C) Deflector to ft.x ft.(m x m) Flow Pressure Ceiling Distance GPM(Umin) PSI(bar) 12 x 12(3.6 x 3.6) 12(45.4) 7.5(0.52) 14 x 14(4.3 x 4.3) 14(53.0) 10.2(0.71) 16 x 16(4.9 x 4.9) 16(60.6) 13.3(0.92) 4 to 6 inches 16 x 18(4.9 x 5.5) 18(68.1) 16.8(1.16) (100to150mm) 18 x 18(5.5 x 5.5) 20(75.7) 20.7(1.43) 16 x 20(4.9 x 6.1) 23(87.1) 27.4(1.89) 12 x 12(3.6 x 3,6) 14(53.0) 10.2(0.71) 14 x 14(4.3 x 4.3) 16(60.6) 13.3(0.92) 16 x 16(4.9 x 4.9) 17(64.4) 15.0(1.04) 6 to 12 inches (150 to 300 mm) 16 x 18(4.9 x 5.5) 20(75.7) 20.7(1.43) 16 x 20(4.9 x 6.1) 23(87.1) 27.4(1.89) Bulletin 935 REES Page 5 of 9 March 2022 wwwseliablesprinkler.com Model KRes58 HSW SIN RA3503 Technical Specifications Finishes Style:Horizontal Sidewall (See Table H) Threads:1/2"NPT or IS07-1 R1/2 Sensitivity Nominal K-Factor:5.8(84 metric) Fast-response Max.Working Pressure:175 psi(12 bar) Temperature Ratings 165°F(74°C) Material Specifications(Ref.Fig.7) Recessed Escutcheons , Thermal Sensor Nickel Alloy fusible link F2 Recessed -` � Sprinkler Frame:Brass Alloy Sprinkler Wrenches („fill( ? ' , f Button:Copper Alloy Model W2 ( ° Sealing Assembly:Nickel Alloy with PTFE Model W1 (recessed) t Load Screw:Bronze Alloy . Deflector:Bronze Alloy Listings and Approvals Lever:Stainless Steel cULus Strut:Stainless Steel Model KRes58 HSW/F2 Figure 5 1-3/4"(44mm) Face of fitting 3/8"(9mm) +/-1/4"(6mm) to finished wall +/-1/4"(6mm) p 2-112"(64mm) MN 1111III,II kL i%11 (21/4") (49mm) ,1 • ' Top of Deflector Down from Nilpp���� 57mm `�_ I Gelling to be Either 4"to 6" . "1J� DIA. DIA. ,`�. %`�� (100 to 150 mm)or 6"to 12" I. (150 to 300 mm)Based on 5/16" I All p Flow&Pressure Selection (8mm) ll ,C% I I 4 Dimensions F2 Recessed Escutcheon Installation Model KRes58 HSW/F2 Sprinkler Hydraulic Design Criteria Table F Minimum Flow and Residual Pressure Max.Coverage Area Ordinary Temp.Rating(165°F/74°C) g Deflector to ft.x ft. m x m) Flow GPM Pressure ( (L./min) PSI(bar) Ceiling Distance 12 x 12(3.6 x 3.6) 16(60.6) 7.6(0.53) 14 x 14(4.3 x 4.3) 18(68.2) 9.7(0.69) 16 x 16(4.9 x 4.9) 21 (79.5) 13.2(0.91) 4 to 6 inches (100 to 150 mm) 16 x 18(4.9 x 5.5) 25(94.7) 18.6(1.28) 16 x 20(4.9 x 6.1) 29(109.8) 25(1.73) 12 x 12(3.6 x 3.6) 22(83.3) 14.4(1.0) 14 x 14(4.3 x 4.3) 22(83.3) 14.4(1.0) 16 x 16(4.9 x 4.9) 26(98.4) 20.1 (1.39) 6 to 12 inches 16 x 18(4.9 x 5.5) 31 (117.4) 28.6(1.97) (150 to 300 mm) 16 x 20(4.9 x 6.1) 33(124.9) 32(2.21) Bulletin 935 Page 6 of 9 March 2022 Reliab www.reliablesprinkler.com Model KRes58 HSWX Residential Sprinkler SIN RA3593 Technical Specifications Finishes Style:Horizontal Sidewall (See Table H) Threads:1/2"NPT or ISO7-1R1/2 Sensitivity Nominal K-Factor:5.8(84 metric) Fast-response Max.Working Pressure:175 psi(12 bar) Temperature Ratings 165°F(74°C) Material Specifications(Ref.Flg.7) Recessed Escutcheons + t Thermal Sensor Nickel Alloy fusible link F2 Recessed Willi{ '_„- Sprinkler Frame:Brass Alloy Sprinkler Wrenches Button:Copper Alloy Model W2 Sealing Assembly:Nickel Alloy with PTFE Model Wt (recessed) Load Screw:Bronze Alloy Deflector:Bronze Alloy Listings and Approvals Lever:Stainless Steel cULus Strut:Stainless Steel Model KRes58 HSWX Sprinkler Components and Dimensions Figure 6 2-1/4'(57mm) Face of fitting 3/8"(9mm) +/-1/4"(6mm) to finished wall +/-1/4'(6mm) Prr 3"(76mm) 4 I II f i 2-1/4' 1.15/16" �. Top of to Deflector Down From • , Ceiling to be Either a'to 6' ill������l '�� (57mm) (49mm) .�J I — 000 to 150 mm)or 6'to 12' I' D� DIA. � (150 to 300 mm)Based on V 5/16" ,II II . IIFlow&Pressure Selection (8mm) Dimensions F2 Recessed Escutcheon Installation Model KRes58 HSWX Sprinkler Hydraulic Design Criteria Table G Minimum Flow and Residual Pressure Max.Coverage Area Flow Pressure Deflector to ft.x ft.(m x m) gpm(1/min) psi(bar) Ceiling Distance 18 x 20(5.5 x 6.1) 29(109) 25(1.72) 20 x 20(6.1 x 6.1) 30(114) 26.8(1.85) 16 x 22(4.9 x 6.7) 33 (125) 32.4(2.23) 4 to 6 inches (100 to 150 mm) 16 x 24(4.9 x 7.3) 38(144) 42.9(2.96) 14 x 26(4.3 x 7.9) 42(160) 52.4(3.75) 18 x 20(5.5 x 6.1) 35(133) 36.4(2.5) 16 x 22(4.9 x 6.7) 38(144) 42.9(2.96) 6 to 12 inches 16 x 24(4.9 x 7.3) 42(160) 52.4(3.6) (150 to 300 mm) 14 x 26(4.3 x 7.9) 46(174) 62.9(4.34) Note:For coverage area dimensions less than or between those listed above,use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Bulletin 935 ELM Page 7 of 9 March 2022 www.reliablesprinkler.com Finishes Table H Standard Finishes Special Application Finishes Sprinkler* F2 Escutcheon Sprinkler* F2 Escutcheon Bronze Brass Bright Brass Bright Brass Chrome Plated Chrome Plated Dull Chrome Dull Chrome White Polyester White Polyester Black Polyester Black Polyester -- — Custom Color Polyester Custom Color Polyester — -- Electroless Nickel PTFE -- *Note:Paint or any other coating applied over the factory finish will void all approvals and warranties. Components Figure 7 Threads Wrench Flat Thermal �I 03Stlb i� Button &Sealing Sensor !iLI' I'll". Assembly Frame Illu igiail Strut&Lever .. �1:. Model W2 4t ,qj Deflector �` ; / Load Screw Model W1 Maintenance Components Reliable Model KRes Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25, 13, Note: Deflector varies by model 13D,and 13R,as well as the requirements of any Authorities Having Jurisdiction. Installation Prior to installation,sprinklers should remain in the original Models KRes fire sprinklers are to be installed in accordance cartons and packaging until used.This will minimize the potential with NFPA 13, 13D,or 13R and as shown in this bulletin. For for damage to sprinklers that could cause improper operation or recessed installations,the Model F2 recessed escutcheon is the non-operation. only escutcheon to be used with the KRes sprinklers. Use of any other recessed escutcheon will void approvals and warranties. Do not clean sprinklers with soap and water,ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuuming For installing Model KRes sprinklers,use only the Model W2 without touching the sprinkler. sprinkler Wrench;for installing Models KRes Recessed Pendent Replace any sprinkler which has been painted(other than factory and Sidewall sprinklers use only the Model W1 sprinkler wrench. Use of wrenches other than those specified may damage these applied)or damaged. sprinklers. A stock of spare sprinklers should be maintained to allow quick Installation of KRes sprinklers in a wall or ceiling will require a hole replacement of damaged or operated sprinklers. diameter of 2-1/4"(57 mm)for F2 recessed escutcheons. Failure to properly maintain sprinklers may result in inadvertent operation or non-operation during a fire event. Install KRes HSW sprinklers with a ceiling to deflector distance that complies with the hydraulic design criteria tables in this bul- letin.The flow arrow on deflector must point away from near wall and"Top"marking must face the ceiling. A'leak tight"sprinkler joint can be obtained with a torque of 8-18 ft-lbs(11—24 N'm). Do not tighten sprinklers over maximum recommended torque. This may cause leakage or impairment of the sprinklers. Bulletin 935 Page 8 of 9 March 2022 fiellabld www.reliablesprinkler.com Listings &Approvals Listed by Underwriters Laboratories Inc. and LlL Certified for Canada(cULus) Guarantee For Reliable Automatic Sprinkler Company guarantee,terms,and conditions,visit www.reliablesprinkler.com. Patents For patents applicable to products contained in this technical bulletin,please visit www.r-s.co Ordering Information Specify the following when ordering: Sprinkler • Model(See Table A) • Temperature Rating • Threads(NPT or IS07-1) • Finish(See Table H) Escutcheon • Model F2 Recessed • Finish(See Table H) Note:A variety of surface mount escutcheons are also available; please refer to Reliable Technical Bulletin 204. Sprinkler Wrench • Model W2(Pendent and HSW) • W1 (Recessed and Concealed) co O n 0, m m m O� Z Bulletin 935 a March 2022 Reliable Page 9 of 9 www.reliablesprinklercom Bulletin 831 November 2021 I■■I ® Model BFG-300 Supervised riellabild Butterfly Valve Grooved cULus Listed,FM Approved Product Description The Reliable Model BFG-300 Supervised Butterfly valves are cULus Listed and FM Approved for fire protection systems. �_ , U.Reliable Supervised Butterfly Valves valves have AWWA C606 grooved end connections.They are available in 2-1/2"(65mm), ` + II P. . 3"(80mm),4"(100mm),6"(150mm),and 8"(200mm)nominal sizes.The valves are listed for 300 psi(20.7 bar)working pressure.The maximum working temperature for the valves is 250°F(120°C). Maintenance The owner is responsible for maintaining the fire protection Supervised Grooved Butterfly Supervised Grooved Butterfly system in proper operating condition.Any system maintenance Valve-Supervised Open Valve-Supervised Closed or testing that involves placing a control valve out of service will eliminate the fire protection that is provided by the fire protection system. Ordering Information The Reliable Supervised Closed Butterfly valves and associated Specify the following when ordering: equipment shall periodically be given a thorough inspection and test.NFPA 25,"Inspection,Testing and Maintenance of Water Model BFG-300 Butterfly Valve Based Fire Protection Systems,"provides minimum maintenance Supervision requirements. • Valve Supervised Open(yellow indicator) • Valve Supervised Closed(white indicator) Guarantee Valve Size • 2-1/2"(65mm) For Reliable Automatic Sprinkler Co.,Inc.guarantee,terms,and • 3"(80mm) conditions,visit www.reliablesprinklercom. • 4"(100mm) • 6"(150mm) • 8"(200mm) Reliable Supervised Butterfly Valve Wiring Diagram-Valve in Supervised Position Figure 1 Supervised Normally Open Valve Supervised Normally Closed Valve FIRE ALARM CONTROL PANEL FIRE ALARM CONTROL PANEL SIAERVISORYCEICOIT SDEERVS0RY CIRCUIT SI.TWO LEADS PER TERMINA] O—REO RED—I --4 —(—Si S1 //A_ RED O O—YELLOW—� ORYELLOW—I EnDNEXT DEVICEOP UNE TCR S1 V U YELLGW OR TEXTIEND DR DEVICE I WHITE I WHITE WHTE WHITE O OIIEUA (1) OIIEW ACTUATOR CASE GROUND ACTUATOR CASE GROUND S2:ONE LEAD PER TERMINAL (� VOLTAGE O VOLTAGE 82 O--BLUE SOURCE S2 /�r ELSE —I BLACK NOTIFICATION DEVICE I SLACK NOTIFICATION DEVICE (LOAM (LOAM Notes:Rated:5A-1/6HP-125/25OVAC 0.5A-125VDC 0.25A-250DC www.re lia ble s prin k l er.c om Reliable Model BFG-300 Supervised Butterfly Valve Grooved Technical Specifications Specifications Pressure Rating: Groove Inlet:AWWA C 606 Ail, 300 psi(20.7 bar) Listings and Approvals Ili ` Material Specifications cULus Listed Body:Ductile Iron ASTM A-536 Nylon-11 Coated FM Approved Disc:ASTM A-536 EPDM Encapsulated Upper and Lower Stems:AISI 420-SS Housing:ASTM A-536 Hand Wheel:ASTM A-536 Flag Indicator:ASTM A-536 I V . Shear Pin:ASTM A-510 Segment Gear:ASTM B-148 or B-584 • Housing Gasket:EDPM Grade E 0-Ring:EDPM Grade E Reliable Supervised Butterfly Valve Specification and Dimensions Figure 2 E Afinr _� zaaaaaa�. `ilBlir4!1 V _. A PA % 'I! ___ 1 fl 1 8310(M II I C - Dimensions-in. mm) Table B Valve Size A B C D E F 2-1/2"(65) 4-1/8(105) 3-5/8(92) 3-13/16(96) 5-1/3(135) 5-5/16(135) 5(128) 3"(80) 4-7/16(112) 3-11/16(95) 3-13/16(96) 5-5/8(142) 5-5/16(135) 5(128) 4"(100) 5-11/16(145) 4-1/4(108) 4-1/2(115) 6-15/16(175) 5-5/16(135) 5(128) 6"(150) 7(179) 5-11/16(146) 5-3/16(132) 8-1/4(209) 7-5/8(193) 8-5/8(220) 8"(200) 8(204) 6-11/16(170) 5-13/16(147) 9-1/4(234) 7-5/8(193) 8-5/8(220) m m La 0 0, rn rn Bulletin 831 Page 2 of 2 rn November 2021 in-1--t'-IJ • www.reliablesprinkler.com 2 Cr_ Bulletin 621 March 2022 MN Model CR Commercial Riser lie r a a 1-1/2"through 8"(40-200 mm) Sizes cULus Listed,FM Approved Features • Cast stainless steel body for 1-1/2"models and 2"threaded " model • Schedule 10 welded body for 2"-8"grooved versions '1' I a • Optional schedule 40 manifold for 2"-4"sizes —.� 0 le • Approved for vertical or horizontal installation Product Description The Reliable Model CR Commercial Riser arrives factory L' " assembled with water flow switch,pressure gauge,and main drain for a cost-effective system riser or floor control assembly.The Model CR is cULus listed(VEOY.EX5980)and FM approved as a unit.The main drain is available with a ball valve or Reliable Test and Drain valve,which is available with a wide selection of 3"(80mm)welded Commercial Riser test orifice K-factor choices.An optional pressure relief valve kit, w/175psi Pressure Relief Kit and Test&Drain Valve(K5.6) available in 175, 185,210,260,and 310 psi(12, 13, 14, 18,and 21 bar)rating,is also available. Model CR Commercial Riser Table A K-Factor for Valve Size End Connections Pressure Material End-to-End Optional Test Rating Take Out Drain Size and Drain Valve* Threaded 8-1/4" (NPT or BSPT) Cast Stainless 1"(25mm) 1-1/2"(40mm) (210mm) Grooved 250 psi Cast Stainless 9-1/2" 1" 25mm (17.2 bar) (241mm) ( ) 2.8(40) Threaded 4.2(60) 2"(50mm) (NPT or BSPT) Cast Stainless 8-1/4 1"(25mm) 5.6(80) (210mm) 2"(50mm) Grooved S10,S40 Steel 13" 1"(25mm) (330mm) 2-1/2"(65mm) Grooved S10,S40 Steel 13" 1-1/4" 2.8(40) (330mm) (32mm) 4.2(60) 13" 1-1/4" 5.6(80) 3"(80mm) Grooved S10,S40 Steel 8.0(115) 300 psi (330mm) (32mm) 11.2(160) (20.7 bar) 13" 4"(100mm) Grooved S10,S40 Steel (330mm) 2"(50mm) 2.8(40) 4.2(60) 6"(150mm) Grooved S10 Steel 13 2"(50mm) 5.6 80 ( ) (330mm) 8.0(115), 8"(200mm) Grooved S10 Steel 13 2"(50mm) 16.8(240) (330mm) ) 'Note:K-factor must be equal to or less than the K-factor of the smallest K-factor installed on the sprinkler system. For sprinkler sys- tems where the smallest K-factor sprinkler on the system is greater than the largest available valve K-factor,use any valve K-factor that will provide a minimum flow of 1 ogpm(38 Ipm)as required to operate a UL Listed Waterflow Switch. www.reliablesprinkler.com Model CR Commercial Riser Threaded End Assemblies(1-1/2"[40mm]&2"[50mm]) Figure 1 B PRESSURE GAUGE 0 Threaded End Basic Assembly w/ 6"...../ Pressure Relief Valve Table B 3-0/AY PRESSURE RELIEF End Manifold A B C D VALVE E Weight \ �� � KG Connection Pipe Size in in in in in lbs �M_ ' in(mm) (mm) (mm) (mm) (mm) (mm) (kg) �l i�1 211,$ 'I'' 1-1/2 12 10-1/2 3 5-1/2 8-1/4 8.3 1/8 A E Al ' ' Threaded (40) (308) (267) (80) (140) (210) (3.8) (TAKE OUT) 111 1=;, s 1il 2 IMP ( �'1) 2 1,8 10-3/4 3-1/4 5-3/4 8-1/4 9.1 ��'I' r T (50) (308) (273) (83) (146) (210) (4.1) / BALL WATERFLOWJ _ 1 VALVE DETECTOR Booy C (DRAIN CONNECTION) BASIC ASSEMBLY(2'[50MM]VERSION SHOWN) WITH OPTIONAL PRESSURE RELIEF KIT R1FGOIG B PRESSURE HANDLE IN TEST POSITION r;AIV'E D - Threaded End w/Test&Drain Valve and Li �' ['' Pressure Relief Kits Tab C 3-WAY 5111111End Manifold A B C D E Weight VALVEPipe Size in i1 in in in Ibs Connection in(mm) (mm) (mm) (mm) (mm) (mm) (kg) .11 WI= tsr-0 r7 A __.�_ a �-i=U�mIE�L 1-1/2 1/8 14-1/4 3 5-1/2 8-1/4 8.3 �I tgI 1�•: Threaded (40) (362) (80) (140) (210) E r�l .- lir 501�i�l Ends (308) (3.8) (TAKEOUT) =J1 (Seems 1) 2 12- 14-12 3-1/4 5-3/4 8-1/4 9.1 VALVE�N (50) 1/8 (308) (368) m"I) (83) (146) (210) (4.1) M - ._ CONNECTION) :;.m is WATERFLOW J DETECTOR-/ MANIFOLD C BODY BASIC ASSEMBLY (2"(50MM]VERSION SHOWN) WITH TEST AND DRAIN VALVE &OPTIONAL PRESSURE RELIEF KIT (TEST AND DRAIN SHOWN IN"TEST"POSmON) Bulletin 621 March 2022 Reliable Page 2 of 5 www.reliahlesprinkler.com Model CR Commercial Riser Grooved End Assemblies(2"[50mmj-8"[200mm]) Figure 2 Grooved End Basic Assembly w/ B Pressure Relief Valve Table D NEE 000-��GAME End Manifold A B C D E Weight ° ''"E Connection Pipe Size in in n in in lbs tR 'St E` in OM)( ) Om) Own) ( ) Ow) Om) 0k9) EEOUWIO 1-1/2 13-12 10-1/2 3 5-1/2 9-1/2 8.3 S [IiI:=.i (40) (343) (267) (76) (140) (241) (3.8) A VALVE ■■II,1 2 15-1/4 14-1/2 5-1/4 6 13 10.7 (50) (367) (368) (133) (152) (330) (4.9) ITAI(E OUT)I' 1t11E• 2-1/2 15-1/4 15 6-3/4 6-1/4 13 12.9 MIETRpY `�� Grooved (65) (387) (381) (171) (159) (330) (5.9) i� '. \� Ij``i Ends 3 15-1/4 16-1/4 7 6-1/2 13 17.6 �[[„ See Fg.2 (80) (387) (413) (178) 165�� �� ( ) ( ) (330) (8.0) p eN 4 15-1/4 19 8-1/4 7 13 21.3 B00 WARMI c �qN`E (80) (387) (483) (210) (178) (330) (9.7) 6 15-1/4 21-1/2 9-1/4 8 13 26.3 BASIC ASSEMBLYg"BOUM1 VERSION SHOWN) (150) (387) (546 WITH OPTIONAL PRESSURE RELIEF KIT ) (235) (2 D3) (330) (11.9) 8 15-1/4 23 10-1/4 9 13 31.0 (200) (387) (584) (260) (229) (330) (14.1) BAWLS PI TEST POSTON • Grooved End w/Test&Drain Valve and Pressure Relief Kits Table E '_ Olt) End Manifold A B C D E Weight rimcE. ® - • 0-'1 - l Connection Pipe Size in in in in in lbs :�:�• ( ) (^ ) (mm) (mm) ( ) (mm) (k9) 1,l -g-m) Q r�+� in mm / O ¢iiJ T 1-1/2 13-12 11-1/2 3-1/2 5-3/4 9-1/2 8.3 v, girl E (40) (343) (292) (89) (146) (241) (3.8) CAKE 1 �� s. . 2 15-1/4 16 5-1/4 6 13 10.7 '-� B AMgNN (50) (387) (406) (133) (152) (330) (4.9) iiiili.% 4 COW ONEmBa+ CPECONj 2-1/2 15-1/4 16-12 6-3/4 6-1/4 13 12.9 (65) (387) (419) (171) (159) (330) (5.9) MwFan I Grooved 800 c Ends 3 15-1/4 17-1/4 7 6-1/2 13 17.6 (see Fig.2) (80) (387) (438) (178) (165) (330) (8.0) BASIC AssEMBLYw•uoMAM1YERsloxsxowp 4 15-1/4 20-12 8-1/4 7 13 21.3 PATH TEST ANO DRAIN VALVE (80) (387) (521) (210) (178) (330) (9.7) A OPTIONAL PRESSURE RELIEF KIT RFAfARO DRAW NWWNRI BEST.POSRpM 6 15-1/4 23 9-1/4 8 13 26.3 (150) (387) (584) (235) (203) (330) (11.9) 8 15-1/4 24-12 10-1/4 9 13 31.0 Notes: (200) (387) K2) (260) (229) (330) (14.1) 1. 1-1/2"grooved version will be cast in stainless steel. 2. 1-1/2"and 2"models will have threaded test and drain valve. Bulletin 621 Page 3 of 5 March 2022 Reliabld www.reliablesprinkier.com Installation Guarantee The Model CR Commercial Riser shall be installed in accordance For Reliable Automatic Sprinkler,Co.,Inc.guarantee,terms,and with NFPA 13,"Standard for the Installation of Sprinkler Systems," conditions,visit www.reliablesprinkler.com. as well as the requirements of any authorities having jurisdiction. When installed vertically,the direction of flow shall be up through Ordering Information the assembly.For horizontal installations,the water flow indicator must be located to the top and drain opening to the bottom.Failure Specify: to follow installation instructions may void the warranty and/or listing of the valve.Verify compatibility of the Model CR Commercial Riser 1. Reliable Model CR Commercial Riser materials with the water supply and the environment where the valve 2. Size will be installed prior to installation. 3. End Connections 4. (Optional)Schedule 40(2"through 4"grooved end only) Maintenance 5. Drain Option(Ball valve or Test and Drain valve) 6. Test orifice K-factor(if ordering Test and Drain valve) The owner is responsible for maintaining the fire protection system 7. (Optional)Pressure Relief Valve Kit in proper operating condition.Any system maintenance or testing that involves placing a system out of service may eliminate the fire protection that is provided by the fire protection system.Notify any Notes: required authorities having jurisdiction and implement appropriate 1. All Model CR Commercial Riser Assemblies come with a 300 precautions prior to proceeding. psi(20.7 bar)UL Listed and FM Approved pressure gauge for 175 psi(12.1 bar)applications. If the Model CR Corn- The Reliable Model CR Commercial Riser shall periodically be given mercial Riser Assembly is to be installed in a higher pressure a thorough inspection and test.NFPA 25,"Inspection,Testing and application,please purchase a 600 psi(41.4 bar)(P/N Maintenance of Water Based Fire Protection Systems,"provides 98248005)pressure gauge.This gauge may or may not be minimum maintenance requirements.Replace any components UL Listed and/or FM Approved at the time of purchase. 2. Unless specified at the time of ordering, pressure relief kits found to be corroded,damaged,worn or non-operable.Increase the frequency of inspections when the valve is exposed to corrosive are installed at the factory. conditions or chemicals that could impact materials and/or operation of the assembly. Note:The water flow switch for the 1-1/2"and 2"cast stainless steel manifold uses a proprietary paddle. This paddle is only available for purchase from Reliable.When replacing water flow switch,order part number 96556923. Bulletin 621 Page 4 of 5 March 2022 LL•I'J r www.reliablesprinkleccom Commercial Riser Ordering Information Part Number Figure 3 6AXXOCPYYZ i Riser Manifold Option Size&End Connections Drain Valve/K-Factor Pressure Relief Valve X yy 04= 1-1/2"BSPT Female SS 00= 1"Ball Valve 0=None 05= 1-/2"Grooved SS 03=1"RASCO T&D Valve K2.8 1 = 175 psi(12.1 bar) 07=2"BSPT Female SS 04=1"RASCO T&D Valve K4.2 2= 185 psi(12.8 bar) 08=1-1/2" NPT Female SS 05= 1"RASCO T&D Valve K5.6 3=210 psi(14.5 bar) 09=2"NPT Female SS 4=260 psi(17.9 bar) 10=2"Grooved SCH10 5=310 psi(21.4 bar) 11 =2"Grooved SCH40 12=2-1/2"Grooved SCH10 01 =1-1/4"Ball Valve 13=2-1/2"Grooved SCH40 26=1-1/4"RASCO T&D Valve K2.8 14=3"Grooved SCH10 06= 1-1/4" RASCO T&D Valve K4.2 15=3"Grooved SCH40 07= 1-1/4" RASCO T&D Valve K5.6 08=1-1/4"RASCO T&D Valve K8.0 09= 1-1/4"RASCO T&D Valve K11.2 16=4"Grooved SCH 10 02=2"Ball Valve 17=4"Grooved SCH40 27=2"RASCO T&D Valve K2.8 18=6"Grooved SCH10 28=2"RASCO T&D Valve K4.2 19=8"Grooved SCH10 10=2"RASCO T&D Valve K5.6 11 =2"RASCO T&D Valve K8.0 12=2"RASCO T&D Valve K11.2 13=2"RASCO T&D Valve K16.8 Notes: 1. 1-1/2"and 2"manifolds have a 1"threaded drain outlet. 2. 2-1/2"and 3"manifolds have a 1-1/4"grooved outlet for Test&Drain valve or a 1-1/4"threaded outlet for ball valve drain. 3. 4",6",and 8"manifolds have a 2"grooved outlet for Test&Drain valve or 2"threaded outlet for ball valve drain CD M io 0 C, Bulletin 621 p Page 5 of 5 O1 March 2022 11>tel.able www.reliablesprinkler.com Groove Inlet Angle Hose Valve44 1 A UL, ULC and FM Approved FPPI® Description Groove Inlet Angle hose valves feature all brass* construction with forged or cast a Y bodies for rigidity and light weight. Rated to 300 psi. Rising Stem.Typical uses are in rack assemblies or any other application which requires a listed fire hose valve. ^- Available in rough brass finish with a red hand wheel. UL, ULC and FM Approved. Installation Specifications Install in accordance with customary installation practices for installing groove end products. Use "rigid"type couplings only and only those that have been listed and Materials: 616 C36000 Cast Brass* approved to 300 psi. (Body) To insurepropergasket seal use a liberal amount of coupling Sizes: p g gasket lubricant (inlet x outlet) approved by the coupling manufacture such as LubeFit®Coupling Grease. Only 21"GRV x MNST use tools suitable for the installation of this product. Improper installation may 21/2"GRV x FNPT result in valve damage as well as personal injury. Finish: Brass *Contains lead.Not for use in water systems intended for human consumption. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL+176D 599-1168 +1 800 344-1822 FM+1 800 344-3775 ©2012 Rre Protection Products,Inc. j C CL 0 LISTED LISTED APPROVED TUU • • , P ` POTTER BELLS The Symbol of Protection PBA AC&PDC-DC Features • Listed for indoor and outdoor use 41¢zo.. • Outdoor use requires BBK-I or HC-BB weatherproof back box • Indoor use mounts directly to standard 4"box • Low current draw • High dB output 0. • AC and DC models �T.T • DC models are motor driven,polarized,and have built in +,` transient protection for supervised alarm circuits • Available in 6",8"and 10"sizes 4>* APPROVED �.i *ULC on PDC-DC Only **FM on PBA-AC Only Description Technical Specifications These vibrating type bells are designed for use as fire or general Dimensions 6"(150mm),8"(200mm)and 10"(250mm) signaling devices.They have low power consumption and high decibel Cover:Steel Finish.Red Powder Coat ratings.The unit mounts on a standard 4"(101mm)square electrical Base:non-corrosive composite material box for indoor use or on a model BBK-1 or HC-BB weatherproof E °IO3°re All parts have corrosion resistant finishes backbox for outdoor applications.Weatherproof backbox model BBK- Model 1313K-1 or HC-BB weatherproof backbox(optional)1 or HC-BB,Stock No.1500001. 24VAC Voltages Available 120VAC Notes I2VDC(10.2 to 15.6)Polarized 24VDC(20.4 to 31.2)Polarized 1. Minimum dB ratings are calculated from integrated sound pressure Indoor or outdoor use(Sec Note 1) Environmental measurements made at Underwriters Laboratories as specified in Limitations -40°to 150°F(40°to 66°C) UL Standard 464. UL temperature range is-30°to 150°F(-34°to (Outdoor use requires weatherproof backbox.) 66°C) AC Bells-4 No.18 AWG stranded wires Termination DC Bells-18 AWG stranded wire 2. Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels Service Use NFPA 13,72,local A143 in an actual installation. 3. ULC only applies to PDC-DC bells. *Specifications subject to change without notice. Size inches Voltage Model Stock Current Typical dB at Minimum dB at A WAR N I N G (ram) Number Number (Max,) 10 It.(3m)(2) 10 ft.(3m)(I) 6(150) I2VDC PDC-6-12 1750500 200mA 96 76 • Installation must be performed by qualified personnel and in accordance with all 8(200) 12VDC PDC-8-I2 1750502 .200mA 96 . national and local codes and ordinances. 10(250) I2VDC PDC-10-t2 1750504 .200mA 96 78 • Shock hazard.Disconnect power source before servicing.Serious injury or death could result, 6(150) 24VDC PDC-6-24 1750501 .20mA 95 77 • Risk of explosion.Not for use in hazardous locations.Serious injury or death 8(200) 24VDC PDC-8-24 1750503 20mA 83 79 could result. 10(250) 24VDC PDC-10-24 1750505 20mA 85 80 6(150) 24VAC PBA246 1806024* .17A 91 78 .r ).�9' --.,*ate%+ k vo `• �r�.,._ �" + t°"'i 8(200) 24VAC PBA248 1808024• .17A 94 10(250) 24VAC PBA2410 1810024* .17A 94 78 In outdoor or wet installations,bell must be mounted with weatherproof backbox,� 6(150) 120VAC PBA1206 1806120* .05A 92 83 BBK-1 or HC-BB. Standard electrical boxes will not provide a weatherproof 8(200) 120VAC PBA1208 1808120" .05A 99 enclosure.If the bell and/or assembly is exposed to moisture,it may fail or create an electrical hazard. 10(250) 120VAC PBAI2010 1810120* .05A 99 86 All DC bells are polarized and have built-in transient protection. •Does not have ULC listing. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 5400777-REVA • 12/20 PAGE 1 OF2 P POTTER BELLS The Symbol of Protection PBA-AC&PDC-DC Installation The bell shall be installed in accordance with NFPA 13,72,or local AH].The top of the device shall be no less than 90"AFF and not less than 6"below the ceiling. 1. Remove the gong. 2. Connect wiring(see Fig.3). 3. Mount bell mechanism to backbox(bell mechanism must be mounted with the striker pointing down). 4. Reinstall the gong(be sure that the gong positioning pin,in the mechanism housing,is in the hole in the gong). 5. Test all bells for proper operation and observe that they can be heard where required(bells must be heard in all areas as designated by the authority having jurisdiction). 4:4fr, � ' Weatherproof Backbox Dimensions 1' : N�NIG ' 'kfro,- Inches (mm) Failure to install striker down will prevent bell from ringing. MODEL BBK-1 OR HC-BB Fig 2 Bell Dimension Inches (mm) Fig �let 0 sv+- _ Tva- s- 0 (IdGmm) (Afi mm) (I:i mm) dt+205mE Itiriww ('j 1...._ �(41 mm) L (eb mml (10A mn) . l 2 11/16" .7 '( (68 mm) / DW6tl T161 C Wiring Rear View Fig 3 D.C. BELLS (OBSERVE POLARITY) A.C, BELLS BED (IN) RED (OUT) WHITE (IN) WHITE (OUT) FROM CONTROL PANEL ' ORTO NEXT END-OF-LINE ELFROM CONTROLN PANEL 11 OR PRECEDING BELL prili RESISTOR PRECEDING BELL BUCK (IN) _• BLACK (OUT) BUCK (IN) �' BLACK (OUT) _I- CAUTION• CAUTION( WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUl LEADS AS SHOWN. WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN_ NOTES: NOTES: 1. OBSERVE POLARITY TO RING D.C. BELLS. 1. WHEN USING A.C. BELLS, TERMINATE EACH EXTRA WIRE SEPERATELY 2. RED WIRES POSITIVE(+). AFTER LAST BELL. 3. BLACK WIRES NEGATIVE (-). 2. END-OF-LINE RESISTOR IS NOT REQUIRED ON AC BELLS . 4. EOL RESISTOR IS SUPPLIED BY FIRE ALARM CONTROL PANEL. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 5400777-REVA • 12/20 PAGE2OF2 Worldwide Contacts wwwtyco-fire.com t,L t7 BLAZEMASTER CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet General Technical Description Data TYCO CPVC Pipe and Fittings pro- Sizes * 7 duced by Johnson Controls are 3/4 Inch to 3 Inch designed exclusively for use in wet Tpipe automatic he TYCO CPVCrPipean sprinkler Fitt ngs are .rip Maximum Working Pressure -� �-t s = produced from BLAZEMASTER CPVC Approvals*e-r compound that is a specially developed UL and C-UL Listed thermoplastic compound composed FM Approved of post chlorinated polyvinyl chloride LPCB Approved (CPVC)resin and state of the art addi- NSF Certified tives.TYCO CPVC Pipe and Fittings are MEA Approved s S easier to install than traditional steel (Refer to Installation Handbook ' pipe systems, and at the same time, dated April 2016 for exact listing/approval provide superior heat resistance and information.) Installation strength as compared to traditional Manufacture Source CPVC and PVC piping materials used U.S.A. TYCO CPVC Pipe and Fittings are to in the plumbing trade. Various adapt- be to be installed in accordance with ers are available to connect CPVC Material Installation Handbook IH-1900. pipe to metallic piping.All female pipe Pipe: thread adapters have brass inserts for ASTM F442,SOR 13.5 durability. Grooved adapters connect Fittings: directly to grooved end valves and ASTM F438(Sch.40) metallic pipe,with flexible grooved end ASTM F439(Sch.80) couplings. ASTM F1970 NOTICE O Orange The CPVC Pipe and Fittings produced with BLAZEMASTER CPVC compound described herein must be installed and maintained in compliance with this document and with the applica- ble standards of the NATIONAL FIRE PROTECTION ASSOCIATION(NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Page 1 of 2 AUGUST 2018 TFP1915 TFP1915 Page 2 of 2 Care and Limited Maintenance Warranty TYCO CPVC Pipe and Fittings are to be For warranty terms and conditions,visit maintained and serviced in accordance www.tyco-fire.com. with this section. Before closing a fire protection system control valve for inspection or main- tenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must first be obtained from the proper authorities and all person- nel who may be affected by this action must be notified. After placing a fire protection system in service,notify the proper authorities and advise those responsible for moni- toring proprietary and/or central station alarms. The owner is responsible for the inspec- tion,testing, and maintenance of their fire protection system and de-vices in compliance with this document,as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSO- CIATION(e.g.,NFPA 25), in addition to the standards of any authority having jurisdiction.Contact the installing con- tractor or product manufacturer with any questions. Automatic sprinkler systems should be inspected,tested,and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. 1400 Pennbrook Parkway,Lansdale,PA 194461 Telephone+1-215-362-0700 0101E Johnson Controls.All rlpht.rmar,M.AllspeelflOtlons end other Information shown were current Is of document revision dete and are Subject to Change without notice. Johnson '��\�' NATIONAL FIE PROTECTION ASSOCIATION Ond NM we registered trademark.@ Name Flre Noted!.Moocladon. Controls &AZEMASTER A enM anaM al The UNMANCerpytlbn Controls State- Pipe & Supply, Inc. THIS INFORMATION PROVIDED IS BASED ON ASTM GUIDELINES FOR WELDED PIPE SPECIFICATIONS AND ASTM REQUIREMENTS. ACTUAL PIPE AND MATERIAL TEST REPORTS PROVIDED WOULD MEET OR EXCEED THESE GUIDELINES. TEST REPORTS WOULD PROVIDE SPECIFIC AND ACTUAL DETAILS CONCERNING THE MECHANICAL AND CHEMICAL PROPERTIES OF THE ACTUAL PIPE,AS WELL AS ADDITIONAL TESTS RESULTS REQUIRED BY ASTM. SCHEDULE 10 ** Black and Galvanized Steel ERW Pipe Pipe Size Test Pressure Nominal O.D. I.D. Weight/Foot psi 1" 1.315 1.097 1.410 700 1-1/4" 1.660 1.442 1.810 1200 1-1/2" 1.900 1.682 2.090 1200 2" 2.375 2.157 2.640 2300 2-1/2" 2.875 2.635 3.530 2500 3" 3.500 3.260 4.340 1290 4" 4.500 4.260 5.620 1000 5" 5.563 5.295 7.780 1010 6" 6.625 6.357 9.300 1020 8"" 8.625 8.249 16.960 780 "8"wall thickness is 0.188, not SCH 10 or 0.148"wall thickness. COMPOSITION AND PROPERTIES Chemical and mechanical properties requirements are as prescribed by applicable ASTM standards edition January 2006. Chemical Requirements, Percent(Product) C Mn P S Other Specification Grade max max max max ASTM A53 A 0.250 0.950 0.05 0.045 - 1 Residual elements max:Cu-0.40,Ni-0.40,Cr-0.40,Mo-0.15 and V-.08. These live elements combined shall not exceed 1%. Mechanical Properties-Tensile Requirements Stren.th-psi. Yield Tensile Specification Grade Min Max Min Max ASTM A53 A 30,000 - 48,000 - NOTE: Elongation requirements vary with nominal area of test specimen and specified minimum tensile strength of the steel grade. 9615 S. Norwalk Blvd., Santa Fe Springs,CA 90670 • (562)695-5555 • FAX: (562) 692-1054 •www.statepipe.com VA State Pipe & Supply, Inc. THIS INFORMATION PROVIDED IS BASED ON ASTM GUIDELINES FOR WELDED PIPE SPECIFICATIONS AND ASTM REQUIREMENTS. ACTUAL PIPE AND MATERIAL TEST REPORTS PROVIDED WOULD MEET OR EXCEED THESE GUIDELINES. TEST REPORTS WOULD PROVIDE SPECIFIC AND ACTUAL DETAILS CONCERNING THE MECHANICAL AND CHEMICAL PROPERTIES OF THE ACTUAL PIPE,AS WELL AS ADDITIONAL TESTS RESULTS REQUIRED BY ASTM. SCHEDULE 40 Black and Galvanized Steel ERW Pipe Pipe Size Test Pressure Nominal O.D. I.D. Weight/Foot psi 1" 1.315 1.049 1.680 700 1-1/4" 1.660 1.380 2.270 1200 1-1/2" 1.900 1.610 2.720 1200 2" 2.375 2.067 3.660 2300 2-1/2" 2.875 2.469 5.800 2500 3" 3.500 3.068 7.580 2220 4" 4.500 4.026 10.800 1900 5" 5.563 5.047 14.630 1670 6" 6.625 6.065 18.990 1520 8" 8.625 7.981 28.580 1340 COMPOSITION AND PROPERTIES Chemical and mechanical properties requirements are as prescribed by applicable ASTM standards edition January 2006. Chemical Requirements, Percent(Product) C Mn P S Other Specification Grade max max max max ASTM A53 A 0.250 0.950 0.05 0.045 - 1 Residual elements max:Cu-0.40,Ni-0.40,Cr-0.40,Mo-0.15 and V-.08. These live elements combined shall not exceed 1%. Mechanical Properties-Tensile Requirements Strenoth-psi. Yield Tensile Specification Grade Min Max Min Max ASTM A53 A 30,000 - 48,000 - NOTE: Elongation requirements vary with nominal area of test specimen and specified minimum tensile strength of the steel grade. 9615 S. Norwalk Blvd., Sania Fe Springs, CA 90670 • (562)695-5555 •FAX: (562)692-1054 .www.stafepipe.com Grooved End Fitting- Victaulic offers a broad line of fittings in sizes through 48"/1200mm in a variety of straight and $ reducing styles. Most standard fittings are cast of durable ductile iron to precise tolerances. 4.3.m Victaulic standard fittings pressure ratings conform to the ratings of Victaulic Style 77 couplings. All fittings are supplied with grooves or shoulders to permit fast installation without field prepara- tion.The grooved design permits flexibility for easy alignment. These fittings are not intended for use with Victaulic couplings for plain end pipe(refer to Section 14.04 for fittings available for plain end applications). Fittings are provided in various materials including ductile iron,steel or segmentally welded steel NO.zo TEE depending on styles and size. Fittings are painted orange enamel with a galvanized finish avail- able as an option,contact Victaulic for details. VW" Victaulic fittings are designed specifically for use in grooved piping systems. Fittings are provided grooved or with shoulders conforming to standard steel pipe outside diameters.When connecting wafer or lug-type butterfly valves directly to Victaulic fittings with 741 or 743 Vic-Flange®adapt- ers,check disc clearance dimensions with I.D.dimension of fitting. NO.10 ELBOW Advanced Groove System-For 14-247350-600mm piping systems,Victaulic now offers the Advanced Groove System (AGS). Refer to Section 20.05 for AGS fitting details. Stainless Steel-Grooved end fittings are available in Schedule 10 Type 316 stainless steel (Schedule 5,40 and Type 304 available as an option)in various sizes. Fitting center-to-end dimensions will vary depending upon type and schedule. Refer to Section 17.04 and 17.16 for details. jok Aluminum-Grooved end fittings are available in aluminum alloy 356 T6, in sizes from NW 1-8"/25-200 mm. Refer to Section 21.03 or contact Victaulic for details. AGS-ADVANCED GROOVE SYSTEM • ALTERNATE STYLES Extra Heavy EndSeal®"ES"Fittings-EndSeal fittings are available in 2-12"/50-300mm for use with "ES"grooved pipe and HP-70ES EndSeal couplings. "ES"fittings are painted black for easy identification. EndSeal(and standard)fittings may be easily internally coated(by others)for severe service requirements.Always specify"ES EndSeal fittings"when ordering.See Section 07.03 for information on EndSeal fittings. Fittings Machined for Rubber or Urethane Lining(MRL)-For severe abrasive services,Victaulic fittings may be rubber or urethane lined(by others). Lining may be inside diameter/end(abrasion resistance)or wrap-around(corrosion and/or abrasion)machined. Refer to Section 25.03 or contact Victaulic for specific details. • JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.02006 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. jetaUI1C' Dr, I n=M IPS CARBON STEEL PIPE- GROOVED FITTINGS U/.1) 1 rc)oved End Fi.itings 4 it.; NO.10 ELBOW NO.20 TEE FLOW DATA The chart expresses the frictional resistance of various Victaulic fittings as equivalent feet of straight pipe. Fittings not listed can be estimated from the data given,for example,a 221/2°elbow is (Frictional Resistance) approximately one-half the resistance of a 45°elbow.Values of mid-sizes can be interpolated. Size Oimensicn-Feetlm etas Elbows tees 90'Elbows 45'Elbows Actual No.100 No,110 Nominal Outside No.10 1Ya 0 No. 11 114 0 Size Dia Std. Long Std. Long In.lmm . In./mm Radius Radius Radius Radius Branch Run 1 I 1.315 1.7 • 0.8 4.2 1.7 25 33.7 0.5 - 0.2 - 1.3 0.5 2 2.375 3.5 2.5 1.8 1.1 8.5 3.5 50 l 60.3 1.1 I 0.8 0.5 0.3 2.6 1.1 76.1 mm 3.000 4.3 2.1 - 10.8 4.3 76.1 ; _1.3 0.7 3.3 1.3 3 II 3.500 • 5.0 3.8 2.6 1.6 13.0 5.0 80 I 88.9 1.5 1.2 0.8 0.5 4.0 1.5 108.0 mm I 4.250 6,4 _ 3.2 15.3 6.4 ___ __._> 108.0 2.0 0.9 - 4.7 2.0 4 I 4.500 6.8 5.0 3.4 2.1 16.0 6.8 __. 100 114.3 • 2.1 1.5 1.0 0.6 4.9 2.1 1330mm 133.050 2.5 4'1 _.. 20.0 8.1 - - 1.2 6.2 2.5 139.7 mm 5.500 8.5 4.2 ' - 21.0I 8.5 139.7 2.6 1.36.4 2.6 5 5.563 8.5 4.2 21.0 8.5 _ 125 j 1413 2.6 1.3 6.4 2.6 159.0 mm I 6.250 9.4 _ 4.9 - 25.0 9.6 .�_i. 159.0 2.9 1.5 7.6 2.9 165.1 mm 6.500 9,6 s- 5.0 25.0 10.0 165.1 2.9 1.5 - 7.6 3.0 6 6.625 10.0 7.5 i 5.0 3.0 25.0 10.0 150 168.3 3.0 I 2.3 1.5 0.9 7.6 3.0 8 j 8.625 13.0 9.8 6.5 • 4.0 33.0 13.0 200 2191 4.0 3.0 2.0 1.2 10.1 4.0 10 10.750 17.0 12.0 8.3 5.0 41.0 - 17.0 250 .,_ J 273.0 5.2 3.7 2.5 1.5 12.5 5.2 12 12.750 20.0 14.5 1 10.0 • 6.0 50.0 20.0 300 323.9 • 61 4.4 3.0 1.8 15.2 6.1 14 1 14.000 15.8 # 11.0 70.0 23.0 350 j1 355.6 4.8 3.4 21.3 7.0 16 I 16.000 18.0 13.0 80.0 27.0 400 -_I 406.4 # 5.5 4.0 24.4 8.2 18 18000 20.0 14.0 90.0 30.0 __. 450 .__ 457.0 # 6.1 % 4.3 27.4 9.1 20 I 20.000 22.5 16.0 100.0 33.0 _800 508.0 6.9 4.9 30.5 10.1 24 24.000 27.0 19.0 120.0 40.0 600 610.0 tl 8.2 R 5.8 36.6 12.2 26 26.000 28.0 20.5 130.0 43.0 650 I 660.4 8.5 6.3 39.6 13.1 30 l 30.000 34.0 24.0 150.0 50.0 750 762.0 N 10.4 7.3 45.7 15.2 36 i 36.000 40.5 p 28.5 180.0 60.0 _.__.900 f 914.0 12.3 8.7 54.9 18.3 42 42.000 47.0 33.0 210.0 70.0 1050 10670 W 14.3 # 10.1 64.0 21.3 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.02006 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA, uctaulic 117na 9 iPS CARBON STEEL PIPE-GROOVED FITTINGS GroovedEnd Fiytkki s vokw NO.10 ELBOW NO.20 TEE MATERIAL SPECIFICATIONS Fitting: Ductile iron conforming to ASTM A-536,grade 65-45-12. Ductile iron conforming to ASTM A-395,grade 65-45-15, is available upon special request. • Or:Segmentally welded steel as shown under nipples Nipples:(adapter, swaged&hose) • a —4"120—100mm:Carbon steel,Schedule 40,conforming to ASTM A-53,Type F • 5—67125—150mm:Carbon steel,Schedule 40,conforming to ASTM A-53,Type E or S, Gr. B • 8—127200—300mm:Carbon steel,Schedule 30 or 40,conforming to ASTM A-53,Type E or S, Gr. B Flanged Adapter Nipples:(Nipple—see above) • Class 125 Flange: Cast iron conforming to ANSI 13-16.1 • Class 150 Flange: Carbon steel conforming to ANSI B-16.5,raised or flat face • Class 300 Flange:Carbon steel conforming to ANSI B-16.5,raised or flat face Fitting Coatings:Orange enamel • Optional: Hot dip galvanized and others.Some fittings supplied electroplated as standard—see product specifications. Flanged Adapter Nipple Coating: None(Unfinished) • Optional:Orange enamel,hot dip galvanized and others. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2005 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. jctaUilc DCV I n-r n, IPS CARBON STEEL PIPE-GROOVED FITTINGS U./,U j Grooved Enda"tt nnws3 vow stowiros"'"4 ":da t NO.10 ELBOW NO.20 TEE ....rii„,..i..... " CtoE� E to1 - j-CtoE-I �. ill AN _I -t C to E to A �C E Ci E Ct �h tn NO.10 NO.11 NO.12 NO.13 NO.100 NO.110 No.10 No.11 No.12 No. 13 No.1001 No.1101 Size 90'Elbow 45"Elbow 22rh`Elbow 0.w) 11,/n`Elbow(sw) 90'Long Radius Elbow(S) 45°Long Radius Elbow(5) Nominal Actual Approx. Approx. Approx. Approx. Appro, Approx. Sae OutsiUe Die. C to E Wgt.Each C to E Wgt.Each C to E Wgt,Each C to E Wgt.Each C to E Wgt.Each C to I Wgt.Each Inches Inches Inches Lbs. Inches Lbs. Inches Lbs. Inches Lbs. inches Lbs. Inches Lbs. mm mm mm kg mm kg mm kg mm kg mm kg mm kg 8 i 8.625 7.75 29.9 4.25 20.4 ' 7.75 0 20.0 2.00 10.1 14.25 66.0 725 36.0 200 219.1 197 13.6 108 9.3 197 9.1 51 4.6 362 30.0 184 16.3 10 j10.750 9.00 63.3 4.75 , 37.5 - 4.38 sw 30.0 2.13sw 11.8 15.00. 107.0 6.25 57.0 250 I 273.0 229 28.7 121 17.0 111 13.6 54 5.3 381 48.5 159 25.9 12 12.750 10.00 74.0 5.25 66.7 4.88 sw 40.0 2.25 sw 29.3 18.00 156.0 7.50 90.0 300 323.9 254 33.6 133 30.3 124 18.1 57 13.3 457 70.8 191 40.8 14# 14.000 14.00 136.0 5.75 65.0 5.00 sw 46.0 3.50 sw 32.0 I 21.00 s , 164.0 8.75 5 82.0 350 355.6 355.6 61.7 146 29.5 127 I 20.9 89 14.5 - 533 , 74.4 222 37.2 3770mmt, 14.843 14.84 149.3 6.15 82.0 1 .. 377.0 376 9 67.7 156.2 37.2 16# 16.000 16.00 171 0 6.63 88.0 , 5.00 sw 1 58.0 4.00 sw 42.0 24.00 s 210.0 10.00 s 100.0 400 4064 406.4 77.6 168 39.9 ' 127 26.3 102 19.1 610 95.3 254 45.4 426.0 mm t 198.E 6.95 101.3 16.772 426.0 +.. .42b16.77 0 90.1 176.5 45.9 18# 18.000 ' 18.00 228.0 7.46 108.0 5.50 sw t 65.0 4.50 sw 53.2 ' 27.00 s ` 273.0 11.25 s 135.0 450 457.0 457.2 , 103.4 189 50.0 140 I 29.5 114 24.1 686 123.8 286 61.2 I 18898 1890 291.0 7.83 I 141.7 - 480.0 mm t' 480.0 4800 132.0 198.8 64.3 1 - - 20# I 20.000 20.00 298.0 .8.28 ? 138.0 6.00 sw ; 78.6 5.00 sw 65.0 30.00 s 343.0 12.50 s 174.0 500 I 508.0 508.0 135.2 210 62.6 152 36.0 127 29.5 762 1 155.6 318 78.9 530.Omm t! 20.866 I 20.87 355.0 8.64 179.0 I 530.0 530.0 161.0 219.4 81.2 24 4 24.000 I 24.00 438.0 9.94 221.0 7.00 sw 140.0 6.00 we 60.0 36.00 s 516.0 - 15.00 s 251.0 550 I. 610.0 609.6 198.7 252 100.2 178 63.5 152 27.2 914 234.1 381 113.9 630.Omm t' 24.803 24.80 545.0 10.27 255.2 630.0 630.0 247.2 261.0 115.7 _ 14-24 i ,�f 350-600 j Foe AGS fitting information.see publication 20.05 @ Gooseneck design,end-to-end dimension "(sw)Segmentally welded steel #For use on cut grooved systems only.For roll grooved systems,Victaulic offers the Advanced Groove System(AGS).For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales office. t Chinese standard sizes www.victaulic.com \ACteilUiiC VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.02006 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. nra 1 117 nx s IPS CARBON STEEL PIPE-GROOVED FITTINGS U I.0 I Giromfeci End Fittings Iwo* ir1d►itl NO.10 ELBOW NO.20 TEE Tees, Crosses and True Wyes ,-CroE NO.20 Tee i-CtoE-� � �roL� GE NO. 33 True II II N0. 33 True Wye -f / ` �1� II N0.29M Tee with �III C Threaded Branch tE E C€ Ct+TE (Ductile Iron *) � * 5 NO.20 NO 35 NO.33 NO.29M Na.20 No.35 No.33 No.2E1 Size Teo Cross(sw) Tree Wye Ise) Teo v:ith Threaded Ehanrh Nominal Actual i Approx. Approx. Approx. _... Approx. Size Outside bla. C to E Weight Each C to E Weight Each C to LE 1 C to SE Weight Each C to GE C to TE Weight Each Inches Inches Inches Lbs. Inches Lbs. Inches 1 Inches Lbs. Inches Inches Lbs. mm rem mm kg , mm kg mm t min kg min ruin kg 1b 1.050 2.25 0.6 2.25 0.9 - - - 2.25 - 2.25 ' 0.6 20 269 57 0.3 57 0.4 57 57 i 0.3 1 1.315 2.25 1.0 2.25 1.3 2.25 - 2.25 1.1 2.25 2.25 1.0 _._....25 ._. . 33.7 57 ' 0.5 57 0.6 57 57 0.5 57 57 - 0.5 1P)4 1.660 2.75 1.5 2 75 2.1 2.75 2.50 1.5 2.75 2.75 1.5 32 42.4 70 0.7 i 70 1.0 70 64 . 0.7 70 70 0.7 1 Ya 1.900 2.75 2.0 • 2.75 2.5 2.75 2.75 1.8 2.75 2.75 - 2 0 40 48.3 70 0.9 70 1.1 70 70 0.8 70 : 70 '. 0.9 2 2.375 3.25 3.0 3.25 3.8 3.25 - 2.75 2.5 3.25 4.25 3.00 50 60.3 83 1 1.4 83 1.7 83 70 1.1 83 108 1.4 2/ 2.875 3.75 4.3 3.75 6.1 3.75 3.00 4.3 3.75 3.75 4.3 65 73.0 95 2.0 - 95 2.8 95 76 2.0 95 i 95 20 76.1 min 3.000 3.75 5.2 3.75 ! 3.75 5.2(sw) _._ 76.1 95 2.4 - - - - 95 I 95 2.4 3 3.500 4.25 6.8 4.25 10.5 4.25 3.25 6.1 4.25 6.00 6.8 80 88.9 108 3.0 108 4.8 108 • 83 2.8 108 152 • 3.1 3/ 4.000 I 4.50(sw) ; 7.9 4.50 11.5 4.50 3.50 9.6 4.50 4.50 7.9(sw) 90 101.6 114 3.6 j 114 5.2 114 i 89 4.4 114 114 i 73.6 lOB.Omm 4.250 5.00 ( 15.5 • 5.00 5.00 j 15.5 108.0 127 7.0 - - - - 127 127 7.0 4 4.500 5.00 11.9 5.00 15.8 5.00 3.75 10.0 5.00 725 11.9 100 114.3 127 5.4 127 7.2 127 95 4.5 127 184 5.4 414 5.000 5.25(sw) 15.0 5.25 18.5 5.25 5.25 - 15.0(sw) 120 127.0 133 6.8 133 - 8.4 - - - 133 133 ! 6.8 133.0mm 5.20 5.50 178 5.50 5.50 17.8 133 14 133.0 140 8.1 - - - - 140 140 8.1 139.7mm 5.500 5.50 17.8 , 5.50 5.50 ' 17.8 139.7 140 8.1 - - - i - - - 140 140 8.1 5 5.563 5.50 17.8 5.50 20.0 5.50 4.00 15.0 - 5.50 5.50 i 178(sw) 125 141.3 140 8.1 140 : 9.1 140 102 6.8 140 140 8.1 6.250 6.50 271 - - - 6.50 i 6.50 271 159.0mm 159.0 - 165 12.3 - 1 - 165 - 165 . 12.3 165.1mm 6.500 6.50 22.0 6.50 - 28.0 6.50 6.50 • 22.0 165.1 165 10 0 165 12.7 - - - 165 165 10.0 6 6.625 6.50 257 6.50 28.0 6.50 4.50 22.3 6.50 6.50 25.7(sw) 150 168.3 165 11.7 165 12.7 165 114 10.1 165 165 11.7 8 8.625 7.75 47.6 775 48.0 7.75 6.00 36.0 7.75 775 j 47.6(sw) 200 219.1 197 21.6 197 21.8 197 152 16.3 197 197 r 21.6 10 10.750 9.00 99.0 9.00 121.5 t 9.00 6.50 69.9 9.00 9.00 73.0 250 273.0 229 44.9 229 55.1 229 155 31.7 229 229 33.1 12 12.750 10.00 133.0 10.00 110.0 3 10.00 7.00 80.0 10.00 10.00 99.0 300 323.9 254 60.3 254 49.9 254 1 178 36.3 254 254 . 44.9 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2006 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. iiC'----I1C :VT nt O orst a IPS CARBON STEEL PIPE-GROOVED FITTINGS U/.0 1 , r Grooved End 7`"i� � gs ,,tea- NO.10 ELBOW NO.20 TEE Cap Abr NO. 60 (Ductile Iron) NO.60 No.60 No.60 Size Cap Size Cap Nominal Actual T Approx. Nominal Actual T Appras. Size Outside Diameter Thickness Weight Each # Size outside Diameter Thickness Weight Each Inches Inches Inches Lbs. Inches Inches Inches I Lbs. Mal ram rani, kg „A E.•. into ram ram kg V, 1.050 ; 0.88 0.2 6.500 ', 1.00 7.3 165.1 mm 20 26.9 22 0.1 165.1 25 3 3 1 1.315 0.88 0.3 6 6.625 1.00 6.1 25 33.7 22 0.1 150 168.3 25 2.8 P/, 1.660 0.88 _.._ 0.3 __.. 8 8.625 1.19_.... . . .,. 13.1 _.. 32 42.4 22 0.1 200 219.1 30 5.9 11/2 1.900 0.88 0.5 10 10.750 1.25 21.0 40 48.3 22 0,2 250 273.0 32 9.5 2 2.375 0.88 0.6 12 12.750 l 1.25 35.6 50 60.3 22 0.3 300 li 323.9 ` 32 16.2 21/2 2.875 - 0.88 1.0 14# i 14.000 9.50 65 73.0 22 0.5 350 355.6 ' 241 76.1 ram 3.000 0.88 1.2 16# 16.000 10.00 76.1 22 0.5 400 406.4 254 3 3.500 I 0.88 1.2 18# 18.000 11.00 „ 80 88.9 22 0.5 450 457.0 279 3'/1 4.000 0.88 2.5 20# l 20.000 12.00 90 101.6 22 1.1 500 508.0 305 108.0mm 4.250 1.00 2.3 24# 24.000 108.0 25 1.0 600 610.0 4 4.500 1.00 2.5 14-244! Od" For AGS fitting Information,see publication 20.05 100 114.3 25 1.1 350-600 41/: 5.000 1.00 2.5 IMPORTANT NOTES: 120 1270 25 11 ______ 5.250 t.00 as *Steel dish caps available through 247600 mm,contact Victaulic. 133.0mm 133.0 25 2.0 No.60 cap is not suitable for use in vacuum service with Style 72 or 750 couplings. 139.7 mm 5.500 1.00 4.5 No.61 bull plugs should be used,see pg.35. 139.7 25 2.0 #For use on cut grooved systems only.For roll grooved systems,Victaulic 5 5.563 1.00 4.6 offers the Advanced Groove System(AGS).For pricing and availability of cut 125 141.3 ' 25 2.1 groove fittings in this size,contact your nearest Victaulic sales office. 159.0mm 6.250 1.00 6.8 159.0 25 3.1 www.victaulic.com Ctauiid vicTAULic IS A REGISTERED TRADEMARK OF VICTAUUC COMPANY.O 2006 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. -., . n9 111 10 FireLock EZ® Rigid Coupling /�taUiif . Style 009N V 10.64 Material Specifications: Housing: Ductile iron conforming to ASTM A-536,grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. PATENTED Housing Coating: Approvals/Listings: ❑ Orange enamel (North America, Asia Pacific) e uL DS ® LPCB ® ❑ Red enamel (Europe) LISTED ❑ Optional: Hot dipped galvanized See Victaulic Publication 10.01 for more details. Gasket: Grade "E" EPDM (Type A) Product Description: -- — — FireLock EZ products have been Listed by Underwriters The FireLock EZ Style 009N Installation-Ready/1'4 Laboratories Inc., Underwriters Laboratories of Canada Rigid Coupling is for use in the fire protection market. Limited,and Approved by Factory Mutual Research for wet and dry(oil free air)sprinkler services-within the rated The coupling's unique design eliminates loose parts, working pressure. promotes consistent installation and provides substantial gains in productivity. Bolts/Nuts: IMPORTANT Zinc electroplated carbon steel, trackhead meeting the FireLock EZ Style 009N couplings are recommended for physical andg chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. use ONLY on fire protection systems. Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.com I Couplings I Rigid I Style 009N I Publication 10.64 10.64 7072 Rev F Updated 03/2014 ®2014 Victaulic Company.All rights reserved. �CtaUIic' 1 victaulic.com I Couplings I Rigid I Style 009N I Publication 10.64 Listings/Approvals ' _. The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Nominal --- Size cULus FM Vds LPCB Sch.5 Sch.10 —1 Sch.40 Sch.5 Sch.10 Sch.40 inches psi psi psi psi psi psi psi psi mm kPa kPa kPa kPa kPa kPa kPa kPa 11/4 232 365 365 175 I 363 363 365 365 32 1600 2517 2517 1205 2502 2502 2517 2517 1V 232 365 365 175 363 363 365 365 40 1600 2517 2517 1205 2502 2502 2517 2517 2 363 365 365 175 363 363 365 365 50 2502 2517 2517 1205 2502 2502 2517 2517 21/2 N/A 365 365 175 363 363 365 365 65 2517 2517 1205 2502 2502 2517 _ 2517 3653 76.1 mm N/A 2517 N/A N/A 363' N/A 365 365 ----- __ 2502 2517 2517 3 N/A 365 365 175 363 363 365 365 80 2517 2517 1205 2502 2502 2517 2517 4 N/A 365 365 175 363 363 365 365 100 2517 2517 1205 2502 2502 2517 2517 108.0mm N/A N/A N/A N/A 363 363 N/A N/A 2502 2502 5 290 I 365 --- 125 N/A 2000 2517 N/A 2502 2502 1 N/A N/A 133.0mm Refer to Submittal 10.61 139.7mm Refer to Submittal 10.61 165.1mm Refer to Submittal 10.61 6 290 365 363 363 i N/A N/AN/A N/A C-_ 150 2000 2517 2502 2502 8 N/A 290 365 363 ---- 363 200 2000 2517 N/A 2502 2502 WA N/A 1 Listed/Approved for wet and dry pipe systems I>-40°F/-40°C)for continuous use in freezing conditions,use of silicone gaskets Is recommended. Please refer to the Victaulic Installation Manual(I-009N/0o9H)for details concerning when supplemental lubrication is required. 2 cULus listed for DIN 2458 2.6 mmm pipe wall. 3 FM approved for BS 1387 Medium 3.6 mm pipe wall. Speciality Pipe Pipe Size Pressure Rating Pipe Size Pressure Rating Pipe Size Pressure Rating cULus FM cULus I FM cULus FM Sch. inches psi psi Sch. inches psi psi Sch. inches psi psi kPa kPa kPa kPa _ kPa kPa BLT 134-2 2068 2 17 EZT 114-2 365 300 365 MT 1 4-2 300 365 -- _� 2068 2517 2068 2517 DF 7y4_4 300 j 365 FF 1Y4-4 300 365 - 365 2068 I 2517 2068 2517 MLT 1'4-2 N/A 2517 DT 1 Y4-2 2068 2517 FLF 1'/a-4 N/A 300 365 365 ST 1 y,-2 ---N/A _ ' 365 2517 2517 EF 11/4_4 175 175 FLT 114-2 N/A - 365 STF 1Y4-4 I N/A 1 2365 56�1206 1206 2517 EL 114-2 300 365 FLTL 1Y4-2 N/A 365 TF 2y4-4 N/A 365 2068 2517 2517 -- _- --- _— i 2517 300 365 . E140 1'4-2 2068 2517 GL 1Y4-2 300 365 WLS 1'/4-2 300 365 2068 2517 2068 2517 _ 300 365 365 EZF 3 4 — 2068 2517 MF 134-4 20682517 W5T 1 Y4-2 N/A 2517 XL 7 y4_2 300 365 2068 I 2517 10.64 7072 Rev F Updated 03/2014 0 2014 Victaulic Company.All rights reserved. victaulic.com 2 Jctaulic° victaulic.com I Couplings I Rigid I Style 009N I Publication 10.64 • Style 009N Dimensions: . .- r A� :,fir,: . / r ._/... Style 009N Pre-Assembled Style 009N Joint Assembled (Push On Condition) Dimensions • • Actual Maximum Maximum I Allow. Pre-assented (Push On Condition) Joint Assembled We• Nominal Outside Working End Pipe End Weight • Size Diameter Pressure' Load' Separations Bolt/Nut3 X Y X Y Z Each Inches inches psi lbs. inches (No.)size inches inches Inches inches inches lbs. mm mm kPa N mm inches mm mm mm mm mm kg 114 1.660 365 790 0.10 2-4x2 3.10 4.90 2.70 4.90 1.92 1.4 32. 42.4 2517 3514 2.54 M-10 x 2 79 124 69 124 49 0.7 115 1.900 365 1035 1 0.10 2-34 x 2 + 3.30 5.10 3.00 5.10 1.92 1.5 40 48.3 2517 4604 2.54 M-10 x 2 84 129 76 129 49 0.7 2 2.375 365 1616 0.12 2-%x2 3.90 5.60 3.50 5.60 1.95 1.9 50 60.3 2517 7193 3.05 M-10 x 2 99 142 89 142 50 0.9 2Y2 2.875 365 2370 0.12 2-3/4x23 4.50 6.10 4.00 6.10 1.95 2.1 65 73.0 2517 10542 3.05 M-10 x 2% 114 155 102 155 50 1.0 76.1 min 3.000 365 2580 0.12 2-3 x 2'% 4.56 6.00 4.05 6.06 1.94 2.1 76.1 2517 11476 3.05 M-10 x 2'Ya 115.7 152.5 102.8 153.9 49.2 1.0 3 3.500 365 3512 0.12 2-3'a x 2% 5.10 6.70 4.60 6.70 1.95 2.3 80 88.9 2517 15622 I 3.05 M-10 x 2 va 129 170 117 170 50 1.0 4 4.500 365 5805 0.17 2-%x2% 5.95 7.80 5.54 7.47 2.14 2.9 - 100 1143 2517 25822 4.32 M-10x21/2 151 199 141 190 55 13 108.0mm 4.250 365 5175 0.17 2-3Lx2Ya 5.56 7.39 5.28 7.36 2.14 3.1 108.0 2517 23020 4.318 141 1.88 134 187 54 1.4 5 5.563 365 L 5178 0.17 2-'hx3 7.19 9.25 6.7 9.11 2.19 5.0 125 141.3 l 2000 23033 4.318 183 235 170 231 56 2.3 133.0mm Refer to Submittal 10.61 139.7mm Refer to Submittal 10.61 165.1mm Refer to Submittal 10.61 6 6.625 I 365 9997 0.17 I 832 10.29 7.82 10.73 2.17 17 6.0 150 1683 2000 44469 4.318 2-/s x 33/4 1211 261 199 257 55 l 2.7 8 8.625 365 13730 0.17 2-3hx4 10.89 13.31 10.22 13.1 2.5 11.4 200 I 219.1 1620 61074 4.318 277 I 338 260 333 64 5.2 1 Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.See page 1 of this document for Listed/Approved ratings on other pipe.WARNING:FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1%times the figures shown in the chart on page 1,specific to pipe schedule and size. 2 The allowable pipe separation dimension shown is for system layout purposes only.FireLock EZ couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. 3 Number of bolts required equals number of housing segments. General Notes: NOTE:When assembling FireLock EZ couplings onto end caps,take additional care to make certain the end cap is fully seated against the gasket end slop.For FireLock EZ Style 009N couplings,use FireLock No.006 end caps containing the"EZ"marking on the inside face or No.60 end caps containing the"QV EZ" marking on the inside face.Non-Victaulic end cap products shall not be used with Style 009N couplings.IMPORTANT:Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009N coupling.There is no interchanging of gaskets or housings between coupling styles. Use Of Flushseal Gaskets For Dry Pipe Systems NOTE:FireLock EZ couplings are supplied with FireLock EZ Grade"E"Type A gaskets.These gaskets include an integral pipe stop,that once installed provides the similiar benefits as a FlushSeal gasket for dry pipe systems.It should be noted that standard Victaulic FlushSeal gaskets are not compatible and cannot be used with the FireLock EZ couplings. Installation - Note Reference should always be made to the I-100 Victaulic Field Installation Handbook for This product shall be manufactured by Victaulic or to Victaulic specifications.All products the product you are Installing.Handbooks are included with each shipment of Victaulic to be installed in accordance with current Victaulic installation/assembly instructions. products for complete installation and assembly data,and are available in PDF formal Victaulic reserves the right to change product specifications,designs and standard on our website at www.victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic,FireLock EZ,and Installation-Ready are registered trademarks of Victaulic Company, 10.64 7072 Rev F Updated 03/2014 0 2014 Victaulic Company.All rights reserved. victaulic.com 3 ictaulic Victaulic® Flexible Coupling Jataul;c Style 75 06.05 row • 1-87DN25-DN200 Exaggerated for clarity 1.0 PRODUCT DESCRIPTION Available Sizes • 1 -87DN25—DN200 Pipe Material • Carbon steel • Stainless steel Maximum Working Pressure • Accommodates pressures ranging from full vacuum (29.9 in Hg/760 mm Hg) up to 500 psi/3447 kPa/34 bar • Working pressure dependent on material, wall thickness and size of pipe Application • Joins standard roll grooved and cut grooved pipe, as well as grooved fittings, valves and accessories • Provides a flexible pipe joint which allows for expansion, contraction and deflection • Up to 50% lighter in weight than standard Victaulic Style 77 or Style 177N flexible couplings 2.0 CERTIFICATION/LISTINGS ®u. 0 CO (LPCB NOTES • Download publication 19 01 for Fire Protection Certifications/Listings Reference Guide. • See publication 02.06:Victaulic Potable Water Approvals ANSI/NSF for potable water approvals if applicable. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION,MAINTENANCE OR SUPPORT. • • System No. Location Spec Section Paragraph — ---__-------- Submitted By Date Approved Date victaulic.com 06.05 1470 Rev P Updated 10/2017 ®2017 Victaulic Company.All rights reserved. rCt9UI1C' 1 ...,..—._......_.. victaulic.com • 3.0 SPECIFICATIONS-MATERIAL Housing: Ductile iron conforming to ASTM A536, Grade 65-45-12. Ductile iron conforming to ASTM A395, Grade 65-45-15, is available upon special request. Housing Coating: (specify choice) ❑ Standard: Orange enamel ❑ Optional: Hot dipped galvanized ❑ Optional: Contact Victaulic with your requirements for other coatings. Gasket: (specify choice') ❑ Grade "E" EPDM EPDM (Green stripe color code). Temperature range—30"F to+230"F/-34"C to +110"C. May be specified for hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +73°F/+23°C and hot+180°F/+82°C potable water service and ANSI/NSF 372. NOT COMPATIBLE FOR USE WITH PETROLEUM SERVICES OR STEAM SERVICES. ❑ Grade"T" Nitrile Nitrile(Orange stripe color code). Temperature range—20"F to+180"F/-29"C to+82"C. May be specified for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range; not compatible for hot dry air over+140°F/+60°C and water over +150°F/+66°C. NOT COMPATIBLE FOR USE WITH HOT WATER. ❑ Others For alternate gasket selection, reference publication 05.01: Victaulic Seal Selection Guide- Elastomeric Seal Construction. Services listed are General Service Guidelines only.It should be noted that there are services for which these gaskets are not compatible.Reference should always be made to the latest Victaulic Seal Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: (specify choice2) ❑ Standard:Carbon steel oval neck track bolts meeting the mechanical property requirements of ASTM A449(imperial) and ISO 898-1 Class 9.8(metric). Carbon steel hex nuts meeting the mechanical property requirements of ASTM A563 Grade B (imperial - heavy hex nuts)and ASTM A563M Class 9 (metric - hex nuts). Track bolts and hex nuts are zinc electroplated per ASTM B633 ZN/FE5,finish Type III (imperial)or Type II (metric). ❑ Optional (imperial): Stainless steel oval neck track bolts meeting the mechanical property requirements of ASTM F593, Group 2 (316 stainless steel), condition CW. Stainless steel heavy nuts meeting the mechanical property requirements of ASTM F594, Group 2 (316 stainless steel), condition CW, with galling reducing coating. I Optional bolts/nuts are available in imperial sizes only. • • 06.05 1470 Rev P Updated 10/2017 0 2017 Victaulic Company.All rights reserved. victaulic.com 2 ✓ctaulie victaulic.com 4.0 DIMENSIONS Style 75 Y 1+-Z-1 i1r �� rr I � FA MIN lig Pipe End Deflection from Size Separation Centerline3 Bolt/Nut Dimensions Weight Actual Outside Approx. Nominal Diameter Allowable Per Cplg. Pipe Qty. Size X Y Z (Each) inches inches inches inches/ft. imperial inches inches inches lb DN mm mm Degrees mm/m metric mm mm f mm kg 1 1315 0-0.06 0.57 /x 2 2.38 4.27 + 1.77 13 DN25 33.7 0-1.6 2�3 48 2 M10 x 51 61 108 45 0.6 1 1 1.660 0-0.06 0.45 14x 2 2.68 4.61 1.77 1.4 DN32 42.4 0-1.6 2-10 38 2 M10 x 51 68 117 45 0.6 _-�- 1 1.900 0-0.06 i-- 0.40 Bit 2 2.91 4.82 1.77 15 , 1z DN40 48.3 0-1.6 1 -� 33 2 M10 x 51 74 122 45 i 0.6 - 2 2.375 0-0.06 0.32 3/x 2 3.43 5.22 1.88 '- 1.7 DN50 60.3 0-1.6 1 -31 26 2 M10 x 51 87 133 1�-48 --. 0.8_-_ 2 Y: 2.875 0-0.06 026 3L x 2 3.88 5.68 ! 1.88 1.9 73.0. 0-1.6 1 -15' 22 2 M10 x 51 98 144 48 0.9 _, 3.000 0-0.06 026 %x 2 4.00 5.90 1.88 1.9 0N65 76.1 0-1.6 1 -12 22 2 1 M10 x 51 102 150 48 0.9 3 3.500 0-0.06 0.22 1/2 x 2/ ,4.50 7.00 1.88 2.9 DN80 88.9 0-1.6 1-2' 18 2 M 12 x 70 114 178 48 1.3 3'h 4.000 0-0.06 _.----� 0.19 14 x 2 34 5.00 7.50 1.88 2.9 '-_.- DN90 101.6 0-1.6 0-54' 16 2 M 12 x 70 127 191 48 1.3 4 4.500 0-0.13 0.34 14 x 2 34 5.80 : 8.03 2.13 4.1 DN100 1143 0-3.21 -36' 28 2 M12x70 147 204 54 1.9 I 4.250 0-0.13 0.35 'h x 2 3/. 5.55 7.79 2.13 3.7 108.0 0-3.2 1 -41' 29 2 M 12 x 70 141 198 54 1.7 5.000 0-0.13 0.25 i4 x 3,A6.13 9.43 2.13 5.5 127.0 0-3.2 1:-26 21 2 M76 x 83 156 240 54 2.5 5 5.563 0-0.13 0.27 3/ax3'A 6.88 10.07 2.13 5.8 141.3 0-3.2 1 -18 23 2 MI6 x 83 175 256 54 2.6 I 5250 0-0.13 0.28 %x3'/4 6.55 9.37 2.13 6.0 133.0 0-3.2 1 -21 24 2 M16 x 83 166 238 54 2.7 5.500 0-0.13 0.28 4 x 314 6.80 9.59 2.13 6.3 DN12S 139.7 0-3.2 1 -18 24 i 2 M16x83 173 244 54 2.9 -,-- 6.000 0-0.13 .._- 0.21 - - - %x 3 14 7.38_ - 10.48 1.88 6.2 152.4 0-3.2 1 -12 18 2 M16 x 133 187 266 48 2.8 6 6.625 0-0.13 1 -5, 0.23 2 Mix 33/46.00 11.07 2.13 7.0 DN150 168.3 0-3.2 18 M16x83 203 281 54 3.2 r- 6.250 0-0.13 0.24 - 3/4x 3'14 7.63 10.49 2.13---~_ 6.8 -- 159.0 0-3.2' 1 A' 20 2' .M16x83 194 266 54 3.1 6500 0-0.13 0.23 %x 3% 7.84 10.66 I 2.08 6.6 165.1 0-3.2 1 -7 58 2 M16x83 199 271 53 3.0 8515 0-0.13 0.18 3/4x4Y. 10.19 13.75 232 13.2 1 216.3 0-3.2 0-51 46 2 M20 x 108 259 350 59 6.0 8 8.625 0-0.13 0.18 3A x 4 10.34 13.97 2.13 12.4 DN200 219.1 0-3.2 0-S0 14 2- M20 x 108 263 355 I 59 --_ --- 5.6 ' '/. 3 Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled.These figures are maximums;for design and installation purposes these figures should be reduced by: 50%for 34-3'W/DN20-DN90;25%for 4-/DN100 and larger. NOTE • Metric thread size bolts are available(color coded gold)for all coupling sizes upon request.Contact Victaulic for details. • 06.05 1470 Rev P Updated 10/2017 ®2017 Victaulic Company.All rights reserved. victaulic.com 3 ✓ctauLc' Victaulic ) Flexible Coupling ✓ctau6c' Style 75 06.05 1-8YDN25-DN200 Exaggerated for clarity 1.0 PRODUCT DESCRIPTION Available Sizes • 1 -8'/DN25—DN200 Pipe Material • Carbon steel • Stainless steel Maximum Working Pressure • Accommodates pressures ranging from full vacuum (29.9 in Hg/760mm Hg) up to 500 psi/3447 kPa/34 bar • Working pressure dependent on material, wall thickness and size of pipe Application • Joins standard roll grooved and cut grooved pipe, as well as grooved fittings, valves and accessories • Provides a flexible pipe joint which allows for expansion, contraction and deflection • Up to 50% lighter in weight than standard Victaulic Style 77 or Style 177N flexible couplings 2.0 CERTIFICATION/LISTINGS ® LPCB NOTES • Download publication 10.01 for Fire Protection Certifications/Listings Reference Guide. • See publication 0?0 Victaulic Potable Water Approvals ANSI/NSF for potable water approvals if applicable. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION,MAINTENANCE OR SUPPORT. System No. Location ( Spec Section Paragraph Submitted By LDate Approved Date victaulic.com 06.05 1470 Rev P Updated 10/2017 ®2017 Victaulic Company.All rights reserved. 1 ictauliC' victaulic.com 3.0 SPECIFICATIONS — MATERIAL Housing: Ductile iron conforming to ASTM A536, Grade 65-45-12. Ductile iron conforming to ASTM A395, Grade 65-45-15, is available upon special request. Housing Coating: (specify choice) ❑ Standard: Orange enamel ❑ Optional: Hot dipped galvanized Optional: Contact Victaulic with your requirements for other coatings. Gasket: (specify choice') ❑ Grade "E" EPDM EPDM (Green stripe color code). Temperature range—30"F to+230"F/-34"C to+110"C. May be specified for hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +73°F/+23°C and hot+180°F/+82°C potable water service and ANSI/NSF 372. NOT COMPATIBLE FOR USE WITH PETROLEUM SERVICES OR STEAM SERVICES. ❑ Grade"T" Nitrile Nitrile (Orange stripe color code). Temperature range—20"F to+180"F/-29"C to+82"C. May be specified for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range; not compatible for hot dry air over+140°F/+60°C and water over+150°F/+66°C. NOT COMPATIBLE FOR USE WITH HOT WATER. ❑ Others For alternate gasket selection, reference publication 05.01:Victaulic Seal Selection Guide - Elastomeric Seal Construction. Services listed are General Servic e Guidelines only.It should be noted that there are services for which these gaskets are not compatible.Reference should always be made to the latest Victaulic Seal Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: (specify choice2) ❑ Standard:Carbon steel oval neck track bolts meeting the mechanical property requirements of ASTM A449(imperial) and ISO 898-1 Class 9.8(metric). Carbon steel hex nuts meeting the mechanical property requirements of ASTM A563 Grade B (imperial - heavy hex nuts) and ASTM A563M Class 9 (metric- hex nuts). Track bolts and hex nuts are zinc electroplated per ASTM B633 ZN/FE5,finish Type III(imperial)or Type II (metric). ❑ Optional (imperial): Stainless steel oval neck track bolts meeting the mechanical property requirements of ASTM F593, Group 2 (316 stainless steel), condition CW. Stainless steel heavy nuts meeting the mechanical property requirements of ASTM F594, Group 2 (316 stainless steel), condition CW, with galling reducing coating. 2 Optional bolts/nuts are available in imperial sizes only. • • 06.05 1470 Rev P Updated 10/2017 ®2017 Victaulic Company.All rights reserved. victaulic.com 2 ✓ctaulic' Victaulic® Reducing Coupling ,ctaLalia Style 750 06.08 1\1 1.0 PRODUCT DESCRIPTION Available Sizes: • 2 x 1" through 10 x 8/DN50 x DN25 through DN250 x DN200 Pipe Material: • Carbon steel Maximum Working Pressure: • Up to 500 psi/3447 kPa • Working pressure dependent on material,wall thickness and size of pipe Application: • Joins OGS roll grooved and cut grooved pipe, as well as OGS grooved fittings, valves and accessories • Permits direct reduction on piping run • Optional steel washer prevents telescoping of the smaller pipe inside the larger pipe during vertical system assembly Pipe Preparation: • Cut or roll grooved in accordance with publication 25.01: Victaulic Standard Groove Specifications. 2.0 CERTIFICATION/LISTINGS .„�• i LPCB NOTES • Download publication 10.01 for Fire Protection Certifications/Listings Reference Guide. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION,MAINTENANCE OR SUPPORT. I System No. y Location Spec Section Paragraph I Submitted B Date Approved Date Lat victaulic.com O6.0R 1536 Rev L Updated 10/2017 ©2017 Victaulic Company.All rights reserved. 1 JctauliC victaulic.com • 3.0 SPECIFICATIONS- MATERIAL Housing: Ductile iron conforming to ASTM A536, Grade 65-45-12. Ductile iron conforming to ASTM A395, Grade 65-45-15, is available upon special request. Housing Coating: (specify choice) ❑ Standard: Orange enamel. ❑ Optional: Hot dipped galvanized conforming to ASTM A153. (, Optional: Contact Victaulic with your requirements. Gasket: (specify choicer) L_ Grade "E" EPDM EPDM (Green stripe color code). Temperature range—30"F to+230"F/-34"C to+110"C. May be specified for hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +73°F/+23°C and hot+180°F/+82°C potable water service and ANSI/NSF 372. NOT COMPATIBLE FOR USE WITH PETROLEUM SERVICES OR STEAM SERVICES. ❑ Grade"T" Nitrile Nitrile(Orange stripe color code). Temperature range—20"F to+180"F/-29"C to+82"C. May be specified for petroleum products, hydrocarbons, air with oil vapors, vegetable and mineral oils within the specified temperature range; not compatible for hot dry air over+140°F/+60°C and water over+150°F/+66°C. NOT COMPATIBLE FOR USE WITH HOT WATER SERVICES OR STEAM SERVICES. Others ❑ For alternate gasket selection, reference publication 05.01: Victaulic Seal Selection Guide. Services listed are General Service Guidelines only.It should be noted that there are services for which these gaskets are not compatible.Reference should always be made to the latest Victaulic Seal Svler.tion Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts (specify choice2): ❑ Standard: Carbon steel oval neck track bolts meeting the mechanical property requirements of ASTM A449(imperial) and ISO 898-1 Class 9.8(metric). Carbon steel hex nuts meeting the mechanical property requirements of ASTM A563 Grade B (imperial —heavy hex nuts) and ASTM A563M Class 9 (metric—hex nuts). Track bolts and hex nuts are zinc electroplated per ASTM B633 ZN/FE5, finish Type III (imperial) or Type II (metric). ❑ Optional (imperial): Stainless steel oval neck track bolts meeting the mechanical property requirements of ASTM F593, Group 2 (316 stainless steel), condition CW. Stainless steel heavy nuts meeting the mechanical property requirements of ASTM F594, Group 2 (316 stainless steel), condition CW, with galling reducing coating. Assembly Washer(optional): Galvanized carbon steel. 2 Optional bolts/nuts are available in imperial size only 06.08 1536 Rev L Updated 10/2017 ®2017 Victaulic Company.All rights reserved. victaulic.com 2 ictaulic, victaulic. com 4.0 DIMENSIONS Style 750 il v h2-i . -, .� v -z`� rI 1fnlf ''rill 3.lei, - - - - -- Pipe End 1,. Size Separation Deflect.From CL3 Bolt/Nut Dimensions Weight I 1 Approximate Nominal Allowable Per Cplg. Pipe Qty. Size X v z (Each) inches ( inches In./Ft. inches inches ! inches inches lb DN mm Degrees mm/m mm mm mm mm kg 2 1 0-0.07 0°-57' 0.20 2 V. x 2 3.38 ( 5.28 1.88 2.7 DN50 x DN25 0-1.8 ,, 17 85 134 48 I 1.2 _ 1 1 0-0.07 0° 5T � 0.20 .__ 2 3L x 2 3.38------ 5.28 . 1.88 2.0 DN40 0-1.8 77 85 134 48 1.0 2' 2 0-0.07 0.16 4.00 5.93 1.88 3.1 x DN50 0-1.8 0°-47 14 2 1L x 2 102 151 48 1.4 2 0-0.07 1 0.16 4.38. 6.63 .1.88 4.6 x 0°-47' 2 / x 2% DN65 DN50 iiil 0-1.8 14 111 168 48 21 3 x 2 0-0.07 0° 39, 0.13 2 1/2 x 214 4.75 7.13 1.88 4.9 0N80 DN50 0-1.8 11 121 181 48 2.2 2'h ( 0-0.07 1--- 4.75 7.13 1.88 4.3 0 1 b 0°-39' 11 2 1 x 214 121 181 48 2.0 0-0.07 0.13 4.75 7.13 1.88 4.2 DN65 0-lA 0°-39 2 16 x 214 11 121 181 48 1.9 0. .25 8.90 2.25 8.1 J --- 4 x 2 0-0.13 1°-19' 2 % x3Ya 28 6 DN100 DN50 j 0-3.2 25 159 226 57 3.7-� 2 1 'i 0-0.13 0.28 625 8.90 225 8.6 1 0-3.2 - 19. I 25 2 '% 'x3/a 159 226 57 3.9 0-0.13 �-- 0.28 - 6.25 8.90 2.25 6.9 1°-19' 2 1/4x33/4 DN65 0-3.2 25 159 226 57 3.1 3 0-0.13 0.28 6.00 8.90 225 6.7 1°-19' 2 3S x 3% DN80 . 0-3.2 25 152 226 57 3.0 5 4 1 0-0.13 --_ 0.22 7.18 10.70 213 11.2 x 1°-3' 2 14 x 4114 DN100 0-3.2 19 182 272 54 ...,-i--._-. 5.1 4 0 0.13 0.19 8.63 11.90 2.25 15.2 165.1 x DN100' 0-3.2 16 219 302 x 0°-55' 2 V. x 414 57 6.9 6 4 0-0.13 0.18 8.63 11.90 2.25 16.7 DN150 x DN100 0-32 0°-52 15 2 14 x 4+% 219 302 57 7.6 5 0-0.13 0°-52' 0.18 2 14 x 4 Ya 8.31 11.90 2.25 ----- 12.9 -.._._ 0-3.2 15 211 302 57 5.9 8 i 0-0.13 .u.° 0.13. 10.75 14.88 250 23.2 DN200 x 165.1 1 0-3.2 0 -38' 11 2 '% x 5 - i 273 378 64 10.5 6 I 0-0.13 0.13 10.81 14.88 2.50 I 22.4 --_- 0°-38' 2 1/4 x 5 ! DN150 0-3.2 _-:�- 11 275 378 64 102 0.90 13.12 17.26 2.62 31.4 DN250 x DN200 0-32 0°-25 2 1 x 5'h I 8 333 1 438 67 14.2 3 Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled.These figures are maximums;for design and installation purposes,these figures should be reduced by: 50%for 3/-3 W/DN20-DN90;and 25%for 47DN100 and larger. NOTE • Metric thread size bolts are avaialble(colord-coded gold)for all coupling sizes upon request.Contact Victaulic for details. • • 06.08 1536 Rev L Updated 10/2017 ®2017 Victaulic Company.All rights reserved. victaulic.com 3 ✓ctaulic" victaulic.com 4 5.0 PERFORMANCE Style 750 Size Maximum Maximum Working End Nominal Pressure* Load* Inches psi lb DN kPa N 2 1 350 500 DN50 x DN25 2413 -.-.,. 2,225 1 14 350 1000 -!_- __„__—DN40. 2413 4,450 2 Vs x 2 500 2215 DN50 3447 9,850 2 350 1550 DN65 x DNSO 2413 6,900 3 2 350 1550 DN80 x DN50 2413 6,900 2' 500 3250 3447 14,460 350 2475 DN65 2413 11,010 4'----.—2 ._------ -..._350 1550 .__.._.._..i DN100 x DN50 —_--2413 6,900__--- 21 - 350 2275 2413 r 10,125 350 2475 DN65 2413 11,014. 3 500 4810 DN80 3447 21,400 5 4 350 5565 x DN100 2413_ 24,765 6 4 350 5565 DN150 x DN100 2413 24,765 5 350 8500 2413 37,825 8 350 11610 DN200 x 165.1 2413 51,645 6 350 12060 DN150 2413 53,645 10 8 350 20450 DN250 x DN200 2413 90,970 4 Working Presssure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.Contact Victaulic for performance on other pipe and material.Maximum working pressure rating based on larger pipe size.Maximum end load rating based on smaller pipe size. NOTES • WARNING:FOR ONE-TIME FIELD USE ONLY,the Maximum Joint Working Pressure may be increased to 1 S.4 times the figures shown. • For joint pressure ratings on additional carbon steel wall thicknesses,see publication 06 15. • 06.08 1536 Rev I Updated 1D/2017 ®2017 Victaulic Company.All rights reserved. victaulic.com 4 rctaulc victaulic.com 5.1 PERFORMANCE Flow Data - Head Loss • Equivalent lengths of standard weight steel pipe are shown in the tables. All data is based on water flowing at ' +60°F/+16°C. Flow Reducing Flow Expanding Equivalent Equivalent Size Pipe Length Size Pipe Length Small Small Nominal Diameter Nominal Diameter inches ft I inches ft DN 1 m i DN m 2 1 5.9 f 1 2 2.7 DN50 DN25 1.8 DN25 x x DNS0 0.8 1 1 Y2------ 2.0 1'h 2 1.9 DN40 0.6 DN40 x DN50 0.6 21/ x 2 1.9 2 x 215 1.0 DN50 0.6 DN50 0.3 2 1.9 1.0 DN65 x DN50 0.6 D__N65 0.3 3 2 5.5 -:3T 3.5: DN80 x DN50 1.7 DN80 1.1 217, 3.8 4 3.0 1.2 ON100 0.9 3.8 21/2 3 2.5 DN65 1.2 x DN80 0.8 4 2 6.0 4 3.0 DN100 x DN50 1.8 DN100 0.9 2' 6.0 3 2.5 1.8 DN65 x DN80 0.8 6.0 4 _:3.0 DN65 1.8 DN100 0.9 3-----"6.0 3 4 2.5 DN80 1.8 . DN80 x DN100 0.8 I 5 4 3.0 4 5 3.3 x _--_-_-- DN100 0.9 DN100 x 1.0 4 6.0 4.6 165.1 x DN100 1.8 165.1 1.4 6 4 6.0 6 4.6 DN150 x DN100 1.8 DN150 1.4 5 4.5 5 6 2.3 ----` 1.4 x DN150 0.7 8 7.3 8 5.4 DN200 x 165.1 2.2 i 165,1 x DN200 ' 1.7 6 7.3 I 6 8 6.0 DN150 22. x DN DN200 1.8 10 8 8.7 8 10 63 DN250 x DN2001 2.7 1 I DN200 x DN250 1.9 • 06.08 1536 Rev L Updated 10/2017 ®2017 Victaulic Company.All rights reserved. victaulic.com 5 Jctaul,c' IPS CARBON STEEL PIPE 10 � `��� �s FIRE PROTECTION PRODUCTS • iCtaUIiC° An�9001 certified company Style 005 GaIsket System' FireLock' PPIEN,PENDING Rigid Coupling with Vic-PIusTm Gasket System PRODUCT DESCRIPTION FireLockTM Style 005 rigid Sprinkler Systems.Angle- ONLY on fire protection coupling has a unique,pat- pad design permits assem- systems. '{l ented angle-pad design bly by removing one nut/ which allows the housings bolt and swinging the Vic-Plus Gasket System: to offset while clamping the housing over the gasket. Victatilic®now offers a gas ` grooves. By permitting the This reduces components ket system which requires housings to slide on the to handle during assembly; no field lubrication.The angled bolt pads,rigidity is speeds and eases installa Vic P1usTM System(patent obtained. tion on pipe grooved to pending)is dry,clean, and PatentedVictaulic specifications. non toxic.It reduces The FireLock couplings assembly time substantially provide rigidity for valve Style 005 FireLock cou- and eliminates the mess I� ��I connections,fire mains and plings with the Vic- and chance of long straight runs. Support P1usTM Gasket System over lubrication. , and hanging requirements are designed and rec- Il'L correspond to NFPA 13 ommended for use liii' �` (1`-� [1JCJ [VdS] see notes on page 2. 1002-1e DIMENSIONS SIZE Max. Max. Allow. Dimensions Nominal Work. End Pipe End @ Bolt/Nut Inches/mm Aprx. y •1 ,_ I Inches Press.§ Load Sep,t No.-Size Wgt.Ea. L� Actual mm PSI'/kPa Lbs..*/rl InJrmn Inches/mm X Y Z Lbs./kg gir�r Pit ` 1 Va 350 755 0.05 2-3U X 2 gem , 2 75 4.50 1.88 1.2 :4 ;a 13 a'c 71_.� "4C'. .1'. 1, 350 990 0.05 3.00 4.75 188 1.2 �� i s. te113 -1 I, t2 2-a/•X 2 7; 12 l 14i: -,r. e 2 350 1550 0.07 , 3.50 5.25 1.88 1.6 2.,11 „yno 1,7 2-%X2, $SS l.' 1ac Rated for wet and dry sprinkler 2% 350 2270 0.07 4.00 5.75 1.88 1.9 systems at 350 PSI(2413 kPa)for ,<y t, 2a l a 2-is X 21s 1/a-4N(42,4-114,3 mm)sizes 350 2475 0.07 4.13 5.75 1.88 1.9 and 300 PSI(2068kPa)for 41- 76,1 mm 11r 1i;; 2-%X 21/z I, 1,,,,; 14,, 9 8"(108,0-219,1 mm)sizes; 3 350 3365 0.07 4.63 6.13 1.88 2.1 Schedule 10 roll grooved or >s,s -,1 I 3 -.1:lco 2-%X 21/2 11? 15r; 1.1 10 Schedule 40 cut or roll grooved 4 350 5565 0.16 5.75 7.25 2.13 3.1 steel pipe.Style 005 is rigid and 3 ,113 _'-177 1 2-%X 21/e ,,1 1,3., does not accommodate expan- 300 4255 0.16 Sion,contraction or angular 108,0 mm ,,_;;,;; <;i 1,i 1 ; 2-s/•X 2 k 5.63 7.,. 2.13 3.1 gu deflection. 5 300 7290 0.16 6.88 9.00 2.13 4.5 ?Nil .P-1.15 .11 2-1/z X 2s/i , g?.a ,.1 •i.0 133,0 mm 300 6495 0.16 6.63 9.00 2.13 'lied ;e9o_1 2-1/2 X 2% r. ,,,, did 4.5 _ t.0 300 7125 0.16 139,7 mm pi;is 2-1k X 2s/a 6.88 9.00 2.13 4.8 t :1,.,1 r1 ... '.4 "9 6 300 10340 0.16 8.00 10.00 2.13 5.0 2l'C1�: ;i1:?3 .4' 2-2X2% c(i -.... 159,0 mm 300 9200 0.16 2-s/e X 4/a 7.63 10.00 2113 5.5 Iv. . fit; 300 9955 0.16 165,1 mm 8.15X . 1,,, 2,„4 5.5 8 300 17525 0..19 10.50 13.13 2.63 11.3 21,,i 2,0ee -SptX` 2-s X 41/ ; •a§t Refer to notes on page 2. Victaulic®World Headquarters•P.O.Box 31,Easton,PA 18044-0031 •4901 Kesslersville Rd.,Easton,PA 18040•1-800-PICK VIC•FAX:610/250-8817•www.victaulic.com 1538 Hev.E 10/00 ®Registered Trademark of Victaulic ©Copyright 1999 Viclaulic Printed in U.S.A. MATERIAL SPECIFICATIONS Housing:Ductile iron conform- Inc.and Approved by Factory Bolts/Nuts:Heat treated car- ing to ASTM A-395,grade 65- Mutual Research for wet and bon steel,zinc electroplated to 45-15,and ASTM A-536,grade dry(oil free air)sprinkler ser- ASTM B-633;Track head bolt 65-45-12. vices up to the rated working conforming to ASTM A-183 Housing Coating:Orange pressure using the Grade"E" minimum tensile 110,000 PSI enamel Type A Vic-Plus Gasket (758340 kPa);Flanged hex nut O Optional:Hot dipped galva- System,requiring no field conforming to ASTM A-563, nized lubrication. Grade A. Gasket: For dry services,Victaulic t Standard gasket and FlushSeal gasket ❑ Grade"E"EPDM-Type A continues to recommend the approved for dry pipe systems to-40*F use of Grade"E" e A (-40°C). Supplemental lubricant is rec- Vic-Plus Gasket System tTyp ommended for services installed at or (Violet color code).FireLock F1ushSeale Vic-Plus Gasket continuously operating below 0°F products have been Listed by System.Contact Victaulic for (-18*C). Victaulic continues to recom- Underwriters Laboratories details. mend the use of FlushSeal gaskets for dry services. The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies.Contact Victaulic for performance on other pipe and the latest listings and approvals. t0.02-2A Rated Working Pressure Rated Working Pressure Pipe Size Pipe Size Schedule Inches UL ULC FM Schedule Inches UL ULC FM 5 11 -3 175 175 175 4 300 300 300 EZ 11/4-4 350 350 350 6 175 175 175 10,40 5-8 300 300 300 SF 11/4-4 300 300 300 BLT 111/4-2 300 300 300 Super 40 11/4-2 300 300 300 11/4-4 300 300 300 TL 11/4-2 300 300 300 DF 6 175 175 175 WLS 1'/a-2 300 300 300 DT 11/4-2 300 300 300 XL/XL-II 11/4-3 300 300 300 EL 11/4-2 300 300 300 NOTES: 5 refers to Listed/Approved EL refers to Listed/Approved Super 40/XL refers to Listed/ Schedule 5 steel sprinkler pipe. Eddylite steel sprinkler pipe Approved Super 40 or Super XL 10 refers to Listed/Approved manufactured by Bull Moose Tube steel sprinkler pipe manufactured Schedule 10 steel sprinkler pipe. Co. by Allied Tube and Conduit 40 refers to Listed/Approved EZ refers to Listed/Approved Corporation. Schedule 40 steel sprinkler pipe. EZ-Flow steel sprinkler pipe WLS refers to Listed/Approved manufactured by Northwest Pipe steel sprinkler pipe manufactured BLT refers to Listed/Approved &Casing Co. by Wheatland Tube Company. steel sprinkler pipe manufactured SF refers to Listed/Approved XL/XL-Ureters to Listed/Approved by American Tube Company. Super-Flo steel sprinkler pipe XL or XL-II steel sprinkler pipe DF refers to Listed/Approved manufactured by Allied Tube and manufactured by Allied Tube and Dyna-Flow steel sprinkler pipe Conduit Corporation. Conduit Corporation. manufactured by American Tube SL refers to Listed/Approved steel Company. pp sprinkler pipe manufactured by DT refers to Listed/Approved Dyna Western Tube and Conduit Thread steel sprinkler pipe Corporation. manufactured by American Tube Company. NOTES "Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accor- dance with Victaulic specifications.Contact Victaulic for performance on other pipe. WARNING:FOR ONE TIME FIELD TEST ONLY,the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown. t For field installation only.FireLock Style 005 couplings are essentially rigid and do not accommodate expansion/contraction. g)Number of bolts required equals number of housing segments. Metric thread size bolts are available(color coded gold)for all coupling sizes upon request.Contact Victaulic for details. §Style 005 couplings are VdS and LPC Approved to 12 Bar(175 PSI). WARNING:Piping systems must always be depressurized and drained before attempting disassembly and removal of any Victaulic piping products. This product shall be manufactured by Victaulic Company.All products shall be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. 10.90 - 2 Victaulic® Drain Elbow ✓ctaul/c' No. 10-DR 10.05 Material Specifications Housing: Ductile iron conforming to ASTM A-536,grade 65-45-12. Housing Coating: (specify choice) Standard: Orange enamel. ❑ Optional: Hot dipped galvanized and others. Approvals/Listings See Victaulic publication 10.01 ter details Product Description No. 10-DR drain elbows are specifically designed for use on fire protection standpipes. The drain is drilled and tapped for a 1"/25 mm NPT outlet. Constructed of durable ductile iron all sizes conform to the ratings of Style 77 couplings. No.10-DR elbows are supplied with grooves or shoulders. These fittings are not intended for use with Victaulic Plain End couplings. When connecting wafer or lug-type butterfly valves directly to Victaulic drain elbows with Style 741 or 743 Vic-Flange®Adapters or Style 744 FireLock® Flange Adapters, check disc clearance dimensions with the I.D. dimension of the fitting. Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By I Date I Date Fittings I Elbow I No. 10-DR I Publication 10.05 10.05 1509 Rev E Updated 11/2013 0 2013 Victaulic Company.All rights reserved. victaulic.com 1 �ctaul lC Fittings I Elbow I No. 10-DR I Publication 10.05 Dimensions No 10-DR ditoEII P H h—I- C to E Fe-- Fitting Size Dimensions Actual Outside Approximate Weight Nominal Size Diameter C-E H P Each inches inches inches inches inches lbs. mm mm mm mm mm kg 2ll 2.875 3.75 2.75 1.68 5.2 65 73.0 95 70 43 2.4 r 3 3.500 4.25 2.75 2.10 5.3 80 88.9 108 70 53 2.4 4 4.500 5.00 2.75 2.60 8.8 100 114.3 127 70 66 4.0 6 6.625 6.50 2.75 3.65 18.7 150 168.3 165 70 93 85 --- Installation -----_- Note Reference should always be made to the 1-100 Victaulic Field Installation Handbook for Thls product shall be manufactured by Victaulic or to Victaulic specifications.All products the product you are installing.Handbooks are Included with each shipment of Victaulic to be installed in accordance with current Victaulic installation/assembly Instructions. products for complete installation and assembly data,and are available in PDF format Victaulic reserves the right to change product specifications,designs and standard on our website at www.victeulic.com. equipment without notice and without Incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic".FlreLock and Vic-Flange are registered trademarks of Victaulic Company. 10.05 1509 Rev E Updated 11/2013 0 2013 Victaulic Company.All rights reserved. victaulic.com 2 ✓ctaulic' Worldwide wwwtyco-fire.com ti,ici Contacts BLAZEMASTER CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet General Technical Description Data TYCO CPVC Pipe and Fittings pro- Sizes duced by Johnson Controls are 3/4 Inch to 3 Inch designed exclusively for use in wet Maximum Working pipe automatic fire sprinkler systems. Pressure 175 The TYCO CPVC Pipe and Fittings are psi " produced from BLAZEMASTER CPVC Approvals ; compound that is a specially developed UL and C-UL Listed +�` k.. thermoplastic compound composed FM Approved of post chlorinated polyvinyl chloride LPCB Approved :. s : ',kr (CPVC)resin and state of the art addi- NSF Certified tives.TYCO CPVC Pipe and Fittings are MEA Approved easier to install than traditional steel (Refer to Installation Handbook IH-1900 s .�"� 1� ., `-' pipe systems, and at the same time, dated April 2016 for exact listing/approval provide superior heat resistance and information.) strength as compared to traditional Manufacture Source Installation CPVC and PVC piping materials used U.S.A. TYCO CPVC Pipe and Fittings are to in the plumbing trade. Various adapt- be to be installed in accordance with ers are available to connect CPVC Material pipe to metallic piping.All female pipe Pipe Installation Handbook IH-1900. thread adapters have brass inserts for ASTM F442,SDR 13.5 durability. Grooved adapters connect Fittings: directly to grooved end valves and ASTM F438(Sch.40) metallic pipe,with flexible grooved end ASTM F439(Sch.80) couplings. ASTM F1970 NOTICE O Orange The CPVC Pipe and Fittings produced with BLAZEMASTER CPVC compound described herein must be installed and maintained in compliance with this document and with the applica- ble standards of the NATIONAL FIRE PROTECTION ASSOCIATION(NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing con trac- tor or product manufacturer with any questions. IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Page 1 of 2 AUGUST 2018 TFP1915 TFP1915 Page 2 of 2 Care and Limited Maintenance Warranty TYCO CPVC Pipe and Fittings are to be For warranty terms and conditions,visit maintained and serviced in accordance www.tyco-fire.com. with this section. Before closing a fire protection system control valve for inspection or main- tenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must first be obtained from the proper authorities and all person- nel who may be affected by this action must be notified. After placing a fire protection system in service,notify the proper authorities and advise those responsible for moni- toring proprietary and/or central station alarms. The owner is responsible for the inspec- tion,testing, and maintenance of their fire protection system and de-vices in compliance with this document,as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSO- CIATION(e.g., NFPA 25),in addition to the standards of any authority having jurisdiction.Contact the installing con- tractor or product manufacturer with any questions. Automatic sprinkler systems should be inspected,tested,and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. 1400 Pennbrook Parkway,Lansdale,PA 194461 Telephone 41-215-382-0700 {�f� ,/111�I Coale Johnson Controls.AP rights reserved.OH speelneellens end ether Information shown were current S.of document date and ere subject change sltnout notice. Johnson /JJ:(0 NATIONAL FIRE PPOTECIpN ASSOCIATION and NFPA ate,uplaterod YWamvk,of Naeonal Fro Peaocncn McOeloton; Controls BLAZEMAOTER S.bMmmnk q lM Lubrizol Larporane n 0 APPENDIX A-PIPE FITTINGS TEE �„� n0 ia1.i -�• -• T/0 UM—T/O Nominal Nominal Approx. Pipe Size Take-Out Pipe Weight ANSI Inches Inches Schd. Lbs. P/N DN (mm) (kg.) 3/4 0.625 40 0.11 DN20 (15,9) (0.05) 80000 1 0.687 40 0.19 80001 DN25 (17,4) 0.09) 1-1/4 0.875 40 0.26 0N32 (22,2) (0.11) 80002 1-1/2 1.062 0.51 DN40 (27,0) 80 (0.23) 80003 2 DN50 1375 80 0.90 80004 (34,9) (0.41) 2-1/2 1.562 80 1.59 80005 DN65 (39,7) (0.72) 3 1.812 80 2.41 80006 DN80 (46,0) (1.09) APPENDIX A-PIPE FITTINGS 0 REDUCING TEE 1 of 2 C z m° L mN x M Y �.. w T/0 T/O a al c 2 0. J¢ Nominal Pipe Size Nominal Take-Out Approx. ANSI InchesInches(mm) Pipe Weight P/N Schd. Lbs. X Y Z X Y Z (kg.) m 3/4 3/4 1 0.750 0.750 0.625 0.14 'a DN20 DN20 DN25 (19,0) (19,0) (15,9) 40 (0.06) 80132 go 1 3/4 3/4 0.562 0.562 0.750 0.14 DN25 DN20 DN20 (14,3) (14,3) (19,0) 40 (0.06) 80133 1 3/4 1 0.750 0.687 0.750 0.17 DN25 DN20 DN25 (19,0) (17,4) (19,0) 40 (0,07) 80134 st 1 1 3/4 0.625 0.625 0.812 0.16 DN25 DN25 DN20 (15,9) (15,9) (20,6) 40 (0,07) 80260 c 1-1/4 1 3/4 0.625 0.625 0.937 0.21 DN32 DN25 DN20 (15,9) (15,9) (23,8) 40 (0,09) 80135 1-1/4 1 1 0.750 0.750 0.937 0.22 DN32 DN25 DN25 (19,0) (19,0) (23,8) 40 (0,09) 80136 vA 1-1/4 1 1-1/4 0.937 0.937 0.875 40 0.26 2.80137 ti DN32 DN25 DN32 (23,8) (23,8) (22,2) (0,11) �3 1-1/4 1-1/4 3/4 0.625 0.625 0.875 0.23 DN32 DN32 DN20 (15,9) (15,9) (22,2) 40 (0,10) 80261 1-1/4 1-1/4 1 0.750 0.750 0.875 0.26 DN32 DN32 DN25 (19,0) (19,0) (22,2) 40 (0,11) 80262 1-1/4 1-1/4 1-1/2 1.000 1.000 1.000 80 0.43 80138 as DN32 DN32 DN40 (25,4) (25,4) (25,4) (0,19) a 1-1/2 1-1/4 3/4 0.562 0.562 1.000 80 0.36 80140 DN40 DN32 DN20 (14,3) (14,3) (25,4) (0,16) 1-1/2 1-1/4 1 0.562 0.562 1.062 0.38 DN40 DN32 DN25 (14,3) (14,3) (27,0) 80 (017) 80141 - 1-1/2 1-1/2 3/4 0.562 0.562 1.000 0.36 `m DN40 DN40 DN20 (14,3) (14,3) (25,4) 80 m (016) 80263 a 1-1/2 1-1/2 1 0.562 0.562 1.062 80 0.38 80264 DN40 DN40 DN25 (14,3) (14,3) (27,0) (0,17) 1-1/2 1-1/2 1-1/4 0.875 0.875 1.000 0.45 DN40 DN40 DN32 (22,2) (22,2) (25,4) 80 (0,20) 80275 .2 2 2 2 3/4 0.750 0.750 1.375 0.61 r 0 DN50 DN50 DN2 (19,0) (19,0) (34,9) 80 (0P8) 80265 go 0 APPENDIX A. PIPE FITTINGS REDUCING TEE 2 of 2 z ORO TAD X 11111111111.1 y 11111 T1O TIO Nominal Pipe Size Nominal Take-Out Approx. ANSI Inches Pipe Weight Inches(mm) P/N DN Schd. Lbs. X Y Z X Y Z (kg.) 2 2 1 0.875 0.875 1.375 0.66 DN50 DN50 DN25 (22,2) (22,2) (34,9) 80 (0,30) 80266 2 2 1-1/4 1.125 1.125 1.375 80 0.74 80274 DN50 DN50 DN32 (28,6) (28,6) (34,9) (0,33) 2 2 1-1/2 0.750 0.687 0.750 0.78 DN50 DN50 DN40 (19,0) (17,4) (19,0) 80 (0,35) 80267 2-1/2 2-1/2 1 1.562 1.562 1.562 1.43 DN65 DN65 DN25 (39,7) (39,7) (39,7) 80 (0,65) 80271 2-1/2 2-1/2 1-1/4 1.562 1.562 1.562 1.46 DN65 DN65 DN32 (39,7) (39,7) (39,7) 80 (0,66) 80272 2-1/2 2-1/2 1-1/2 1.562 1.562 1.562 80 1.48 80273 DN65 DN65 DN40 (39,7) (39,7) (39,7) (0,67) 2-1/2 2-1/2 2 1.562 1.562 1.562 80 1.50 80276 DN65 DN65 DN50 (39,7) (39,7) (39,7) (0,68) 3 3 1-1/2 1.812 1.812 1.812 2.28 DN80 DN80 DN40 (46,0) (46,0) (46,0) 80 (1,03) 80270 3 3 2 1.812 1.812 1.750 80 2.25 80268 DN80 DN80 DN50 (46,0) (46,0) (44,4) (1,02) 3 3 2-1/2 1.812 1.812 1.812 2.44 DN80 DN80 DN65 (46,0) (46,0) (46,0) 80 (1,11) 80269 APPENDIX A-PIPE FITTINGS m CROSS&REDUCING CROSS -i; 0.7 ma O„I- T/O 0m - k_ Jii1. 0 0 N II I T/0 mo n0 NM T/o a Nominal Nominal Approx. Pipe Size Take-Out Pipe Weight ANSI Inches Inches Schd. Lbs. P/N Ti DN (mm) (kg.) t iii 3/4 0.562 40 0.13 80009 ~❑ DN20 (14,3) (0,06) 1 0.687 40 0.23 80010 DN25 (17,4) (0,10) 1-1/4 0.937 40 0.34 80011 " DN32 (23,8) (0,15) m 2 1-1/2 1.062 B0 0.67 80012 DN40 (27,0) (0,30) 2 1.312 1.00 DN50 (33,3) 80 (0,45) 80013 v V 2-1/2 1.562 1.91 E 0N65 (39,7) 80 (0,87) 80014 '3 3 1.812 80 2.89 80008 DNBD (46,0) (1,31) x .5 Nominal Pipe Size Approx. d a ANSI Inches Nominal Take-Out Pipe Weight P/N a DN Inches(mm) Schd. Lbs. (kg.) 1 1 3/4 3/4 0.875 0.875 0.875 0.875 0.28 DN25 DN25 DN20 DN20 (22,2) (22,2) (22,2) (22,2) 40 (0.13) 8001525 0 e 0. a a a c co m« m aE I E° -c 0 APPENDIX A- PIPE FITTINGS 90'ELBOW&REDUCING ELBOW X Il„j no /'� Y — T/O Elbow Nominal Nominal Approx. Pipe Size Take-Out Pipe Weight P/N ANSI Inches Inches Schd. Lbs. DN (mm) (kg.) 3/4 0.625 40 0.09 80025 DN20 (15,9) (0,04) 1 0.750 0.14 DN25 (19,0) 40 (0,06) 80026 1-1/4 1.000 0.21 DN32 (25,4) 40 (0,09) 80027 1-1/2 1.062 0.40 DN40 (27,0) 80 (0,18) 80028 2 1.312 0.79 DN50 (33,3) 80 (0,36) 80029 2-1/2 1.562 80 1.14 80030 DN65 (39,7) (0,52) Reducing Elbow Nominal Pipe Size Nominal ANSI Inches Take-Out Approx. DN Inches Pipe Weight P/N (mm) Schd. Lbs. (kg.) X Y X Y 1 3/4 0.687 1.812 40 0.16 80032 DN25 DN20 (17,4) (46,0) (0,07) APPENDIX A- PIPE FITTINGS 0 45° ELBOW c .43_o T/O c' 0 Si T/O 'I S Ell 4�IIr� n "a o,> c2 Ha J¢ Nominal Nominal Approx. Pipe Size Take-Out Pipe Weight P/N ANSI Inches Inches Schd. Lbs. DN (mm) (kg.) To 3/4 0.375 40 0.08 80050 t q DN20 (09,5) (0,04) , 12 1 0.375 0.11 DN25 (09,5) 40 (0,05) 80051 1-1/4 0.750 0.20 DN32 (19,0) 40 (0,09) 80052 p 1-1/2 0.500 80 0.31 80053 a DN40 (12,7) (0,14) 2 0.750 0.56 DNSD (19,0) 80 (0,25) 80054 2-'1/2 1.812 0.89 >. DN65 (46,0) 80 (0,40) 80055 g 0 3 1.000 1.19 _3 DN80 (25,4) 80 (0,54) 80056 x a w¢ a a x a c 0. a O. ¢ I c 0 ,d of a0 Ec 0 APPENDIX A-PIPE FITTINGS COUPLING&REDUCING COUPLING II T/O Coupling Nominal Nominal Approx. Pipe Size Take-Out Pipe Weight P/N ANSI Inches Inches Schd. Lbs. DN (mm) (kg.) 3/4 0.125 40 0.08 80050 DN20 (03,2) (0,04) 1 0.125 40 0.11 80051 DN25 (03,2) (0,05) 1-1/4 0.187 40 0.20 80052 DN32 (04,7) (0,09) 1-1/2 0.500 80 0.31 80053 DN40 (12,7) (0,14) 2 0.750 80 0.56 80054 DN50 (19,0) (0,25) 2-1/2 0.812 0.89 DN65 (20,6) 80 (0,40) 80055 Reducing Coupling Nominal Nominal Pipe Size Take-Out Approx. ANSI Inches Inches Pipe Weight DN (mm) Schd. Lbs. P/N X Y X Y (kg.) 1 3/4 0.125 0.125 0.08 DN25 DN20 (03,2) (03,2) 40 (0,04) 80220 APPENDIX A- PIPE FITTINGS 0 REDUCING BUSHING C _o A« m ll (7 y 0 NIKIM7 —1 T/O mm Nominal 2; Pipe Size Nominal Approx. Ja ANSI Inches Take-Out Pipe Weight P/N DN Inches Schd. Lbs. X Y (mm) (kg.) 1 3/4 0.437 0.04 T DN25 DN20 (11,1) 40 (0.06) 80200 ,2...- ... 1-1/4 3/4 0.500 0.11 g. DN32 DN20 (12,7) 40 (0.05) 80201 1-1/4 1 0.312 0.12 DN32 DN25 (07,9) 40 (0,05) 80202 1-1/2 3/4 0.625 80 (00.16,07) 80203 0 DN40 DN20 (15,9 1-1/2 1 0.500 80 0.14 7.1 80204 DN40 DN25 (12,7) (0,06) 1-1/2 1-1/4 0.375 0.17 DN40 DN32 (09,5) 80 (0,08) 80205 2 3/4 DN50 DN20 0.812 0.27 80 80206 a) (20,6) (0,12) E m 2 1 0.687 80 0.26 80207 43 DN50 DN25 (17,4) (0,12) 2 1-1/4 0.562 80 0.24 80208 DN50 DN32 (14,3) (0,11) 2 1-1/2 0.437 80 0.19 x 80209 DN50 DN40 (11,1) (0,11) da 2-1/2 1 0.937 0.42 a DN65 DN25 (23,8) 80 (019) 80215 2-1/2 1-1/4 0.812 80 0.45 80214 DN65 DN32 (20,6) (0,20) 2-1/2 1-1/2 0.687 60 0.46 80213 a DN65 DN40 (17,4) (0,21) mm 2-1/2 2 0.625 0.29 a DN65 DN50 (15,9) 80 (0,13) 80211 3 2 0.750 0.72 DN80 DN50 (19,0) 80 (0,33) 80210 3 2-1/2 0.500 0.47 c o DN80 DN65 (12,7) 80 (0,21) 80212 t'm of no Ec 0 APPENDIX A- PIPE FITTINGS CAP � T/O--I — Nominal Nominal Approx. Pipe Size Take-Out Pipe Weight ANSI Inches Inches Schd. Lbs. P/N DN (mm) (kg.) 3/4 0.312 40 0.04 80100 DN20 (07,9) (0,02) 1 0.375 0.06 DN25 (09,5) 40 (0,03) 80011 1-1/4 0.437 40 0.10 80102 DN32 (11,1) (0,04) 1-1/2 0.687 80 0.20 DN40 (17,4) (0,09) 80103 2 0.687 0.31 DN50 (17,4) 80 (0,14) 80104 2-1/2 0.875 0.58 DN65 (22,2) 80 (0,26) 80105 3 1.000 80 0.88 80106 DN80 (25,4) (0,40) APPENDIX A- PIPE FITTINGS 0 GROOVED COUPLING ADAPTER 0 Q PIPE m° O m" .D. o � :c: --I Nominal Nominal Take-Out Approx. DI 113 E 2 Pipe Size &Pipe O.D. Pipe Weight 7.1¢ ANSI Inches Inches(mm) Schd. Lbs. P/N DN T/O Pipe O.D. (kg.) 1-1/4 1-1/4 0.875 1-1/4 40 0.78 80160 A DN32 Groove (22,2) 1.660(42,4) (0,35) •2„ 1-1/2 1-1/2 1.125 1-1/2 0.95 0o DN40 Groove (28,6) 1.900(48,3) 80 (0,43) 80161 2 2 0.750 2 1.42 DN50 Groove (19,0) 2.375(60,3) 80 (0,64) 80162 2-1/2 2-1/2 1.562 2-1/2 B0 2.28 80163 T. DN65 Groove (39,7) 2.875(73,0) (1,03) 2-1/2 76,1mm 1.562 76,1mm 2.28 _ DN65 Groove (39,7) 3.000 80 (1,03) 80169 3 3 1.562 3 80 3.00 80164 DN80 Groove (39,7) 3.500(88,9) (1,36) 9 y c SPRINKLER ADAPTER 90°ELBOW E A _3 Y 1; T/O iMj I—� /,�- v AIMX m¢ ( a - T/0 Nominal Pipe Size Nominal s ANSI Inches Take-Out Approx. DN Inches Pipe Weight P/N a° (mm) Schd. Lbs. a X Z X Y (kg.) 3/4 1/2 NPT 0.562 1.000 40 0.20 80199 DN20 (14,3) (25,4) (0,09) 1 1/2 NPT 0.750 1.250 40 0.26 80198 r"DN25 (19,0) (31,7) (0,12) of 1 3/4 NPT 1.062 1.437 40 0.26 80196 E DN25 (27,0) (36,5) (0,12) CD APPENDIX A- PIPE FITTINGS SPRINKLER ADAPTER T/O — T/O Nominal Pipe Size Nominal Approx. ANSI Inches Take-Out Pipe Weight DN P/N Inches Schd. Lbs. (mm) (kg.) 3/4 1/2 NPT DN20 (11,1) 80 (0,09) 80175E 1 1/2 NPT DN25 (11,10 ) 80 80176E (0,10) 3/4 1/2 NPT DN20 0.437 40 (0,07) 80175WL DN25 3/4 NPT (20 40,6) (0,19) 80179 3/4 1/2 NPT 0.500 0.19 DN20 (12,7) 40 (0,09) 80175W 1 1/2 NPT 0.500 40 0.18 80176W DN25 (12,7) (0,08) SPRINKLER ADAPTER(SPIGOT) 7 -I T/O Nominal Pipe Size Take-Out nal Approx. ANSI Inches Pipe Weight P/N DN Inches Schd. Lbs. (mm) (kg.) 3/4 1/2 NPT 0.500 0.16 DN20 (12,7) 40 (0,07) 80177E 1 1/2 NPT 0.562 40 0.20 80178 DN25 (14,3) (0,09) 1 3/4 NPT 0.875 0.40 DN25 (22,2) 40 (0,18) 80180 APPENDIX A-PIPE FITTINGS 0 FEMALE ADAPTER -o A' iIIvig To —T/o w NN Ce Nominal Pipe Size Nominal Approx. ea ANSllnches Take-Out Pipe Weight P/N -'a DN Inches Schd. Lbs. (mm) (kg.) 3/4 0.812 DN20 3/4 NPT (20,6) 80 (0,19) 80142 a DN25 1 NPT 111 1 0.875 80 0.63 80145 2° (22,2) (0,28) 1-1/4 1-1/4 NPT 1.125 1.03 0N32 (28,6) 40 (0,47) 80146 1-1/2 1-1/2 NPT 1.375 1.42 DN40 (34,9) 80 80147 (0,64) s 2 1.687 ,o DN50 2 NPT (42,8) 80 2.66 80148To (1,18) Ii a� MALE ADAPTER �3 ills 9 ga C. —T/O-I a Nominal Pipe Size Nominal Approx. ANSI Inches Take-Out Pipe Weight DN Inches Schd. Lbs. P/N c (mm) (kg.) am 3/4 1.312a DN20 3/4 NPT (33,3) 40 (p35) 80157 a 1 1.3750.56 DN25 1 NPT (34,9) 40 (0,25) 80158 co a fa o- oE a`o Ec 0 APPENDIX B- DO'S AND DON'TS DO'S •Install product according to the manufacturer's installation instructions. •Follow recommended safe work practices. •Make certain that any materials coming in contact with BlazeMaster CPVC are chemically compatible with BlazeMaster CPVC. • If painting is required,use only latex based paints. •Keep pipe and fittings in original packaging until needed. •If stored outdoors,cover the pipe and fittings with an opaque tarp. •Follow proper handling procedures. •Use tools specifically designed for use with plastic pipe and fittings. •Use proper solvent cement and follow application instructions. •Use a drop cloth to protect interior finishes. •Cut the pipe ends square. •Before solvent cementing,deburr and bevel the pipe end. •When solvent cementing,rotate the pipe 1/4 turn when bottoming pipe in fitting socket. •Avoid puddling of solvent cement in fittings and pipe. •Make certain that solvent cement does not puddle in the sprinkler adapter and plug the sprinkler orifice. •Follow the manufacturer's recommended cure times prior to pressure testing. • Fill lines slowly and bleed the air from the system prior to pressure testing. •Support sprinkler properly to prevent movement of the sprinkler when activated. •Install BlazeMaster CPVC pipe and fittings in wet systems only or specially listed dry systems. •Use only chemically compatible insulation and/or glycerin&water solutions for freeze protection. •When glycerine solutions are used,provide an expansion chamber or allow for thermal expansion of the solution. •Allow for movement due to expansion and contraction. •Renew your BlazeMaster CPVC pipe and fittings installation training every two years. APPENDIX B- DO'S AND DON'TS 0 DON'TS •Do not use cutting oils other than CPVC compatible cutting oils, :.a o (ref.FGG/BM/CZT"'System Compatibility Program d._ at www.blazemaster.com). m • Do not use edible oils such as Criscoe as a gasket lubricant. 0 • Do not use petroleum or solvent-based paints,sealants, lubricants or fire stop materials. • Do not use any glycol-based solutions as an anti-freeze. s co • Do not mix glycerin and water solution in contaminated containers. „a • Do not use both Teflon tape and thread sealants simultaneously. Ja • Do not use solvent cement that exceeds its shelf life or has become discolored or gelled. •Do not allow threaded rod within 1/16 inches of the pipe. 2 b °' •Do not allow solvent cement to plug the sprinkler orifice. m o •Do not connect rigid metal couplers to BlazeMaster CPVC grooved adapters. •Do not thread or groove BlazeMaster CPVC pipe. •Do not use solvent cement near sources of heat,open flame,or 'b when smoking. •Do not pressure test until recommended cure times are met. •Do not use dull or broken cutting tool blades when cutting pipe. • Do not use BlazeMaster CPVC pipe that has been stored outdoors, unprotected and is faded in color. •Do not install BlazeMaster CPVC pipe in cold weather without �3 allowing for expansion. •Do not install BlazeMaster CPVC pipe and fittings in dry systems, unless specifically listed for such use. D a a a W m 6 a c o f o of as E� 0 IMPORTANT INFORMATION IMPORTANT INFORMATION WITH REGARDS TO YOUR BLAZEMASTER CPVC FIRE SPRINKLER SYSTEM CONGRATULATIONS,your building structure contains a state of the art life safety system.Your CPVC fire sprinkler system will enhance the safety and security of your building when properly maintained.CPVC Fire Sprinkler Products resist attack from a wide range of chemicals that are corrosive to metallic piping.As with any piping material,there are, however,certain chemicals that can be detrimental to CPVC. Occasionally some of these chemicals may be found in some construction products, site preparations and building maintenance.There are certain things that you need to be mindful of in caring for or working around your CPVC fire sprinkler system. Keep your system clear from contact with the following products and chemicals unless product labels state materials are compatible with CPVC: NOTICE Ordinary considerations Property maintenance services Cleaning Products Detergents,Oils/Lubricants/ Fungicides, Greases,Rubbery Materials Mold Remediation Chemicals, Termiticides/Insecticides For hired contractors&do-it-yourselfers Corrosion Inhibitors,Glycol-based antifreezes, Solder Flux,Thread Sealants Flexible Cable/Wiring (especially communications cabling) Caulks/Mastics,Adhesive, Vinyl/Electrical Tape Non-Approved Spray Foam Insulation Non-Water Based Paint,Paint Thinners Wood FinishesNarnishes You should also avoid the following: • Sitting,standing,hanging, leaning,or resting anything on the pipe,fittings,and sprinklers • Grounding electrical wiring to the pipe or fittings • Ambient temperatures below 40°F/4,4°C where your fire sprinkler system is located. (Unless an approved compatible antifreeze or insulation method is installed.) • Hot work around the pipe,i.e.blow torches,soldering,etc. Be certain that this document is reviewed and understood by anyone working on or around your CPVC life safety system. If you have any questions or need assistance on chemical compatibility with your CPVC fire sprinkler system,contact the manufacturer listed on the pipe. Proper care will help your CPVC fire sprinkler system provide protection for years to came. FOR ADDITIONAL INFORMATION CONTACT "TYCO FIRE&BUILDING PRODUCTS"AT 1-800-381-9312 NOTICE o THIS BUILDING CONTAINS A CPVC FIRE SPRINKLER SYSTEM. THIS CPVC FIRE SPRINKLER SYSTEM IS A LIFE SAFE- () TY ASSEMBLY AND MUST BE TREATED CAREFULLY.PLEASE READ THE FOLLOWING BEFORE ANY ACTIVITY WHICH COULD CONTACT THIS SYSTEM: 5 CPVC piping components may be damaged by certain substances and construction practices. •DO NOT stack,support,hang equipment,or hang flexible wire/cable,especially communications cable,or other material on the c_ fire sprinkler system. 0 •ONLY system compatible materials including,but not limited to solvent cements,caulks,sealants,cutting oils and thread pastes Ca as noted by the CPVC fire sprinkler piping system manufacturer's installation instructions should be used in contact with this system. m •DO NOT expose CPVC products to incompatible substances,such as cutting oils,non-water based paints,packing oils,tradi- C tional pipe thread paste and dope,fungicides,termiticides,insecticides,detergents,building caulks,adhesive tape,solder flux, r- flexible wire/cable(with special consideration for communications cabling),and non-approved spray foam insulation materials. 2 •DO NOT expose CPVC products to edible oils,solvents,or glycol-based anti-freeze fluids. f7 •DO NOT expose CPVC products to open flame,solder,and soldering flux. •DO NOT drop,distort,or impact CPVC products or allow objects to be dropped on them. Do •DO NOT handle CPVC products with gloves contaminated with oils(hydrocarbons)or other incompatible materials. m fA Failure to follow this notice may cause cracks or fractures to develop in CPVC products resulting in property damage due to leaks or flooding.The presence of any visible cracks may require partial or full system replacement.For ad- ditional information contact the general contractor or the fire sprinkler system installer. FOR ADDITIONAL INFORMATION CONTACT"TYCO FIRE&BUILDING PRODUCTS"AT 1-800-381-9312 Rev 3.0 Jan 21,2008_distribul Appendix Appendix Limited Technical Listings/ General 8 A Warranty Installation Data Approvals Description 1 Pipe Hangers Fig. 200 - "Trimline" Adjustable Band Hanger (B-Line Fig. B3170NF) ®TOLCO Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated 113-Lin BFig7 ONFF) COOS Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut LISTED Size Range: Fig. 200 - 1/2" 115mm)thru 8" (200mm)pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other eneral pi pin 9 p p g purposes. Knurled z swivel nut design permits hanger adjustment after installation. Features: • (1/2" (15mm)thru 2" (5omm)) Flared edges ease installation for all pipe �: types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger, Hanger is easily installed around pipe. B For hanger with non-captured nut order Fig. 200S. a • (21/2" 165mm)thru 8" (200mm)) Spring tension on nut holds it securely in I� t hanger before installation.Adjusting nut is easily removed. - - -, :( �I Approvals: Underwriters Laboratories listed(1/2" (15mm)thru 8" (200mm)) in the USA(UL)and Canada (cUL)for steel and CPVC plastic pipe and Fig.200-1/2.zoo 3/4 Factory Mutual Engineering Approved (FM) (3/4" (20mm)thru 8" (200mm)). Fig.200.1 to 200-2 Fig.200-21/7 to 200 8 Conforms to Federal Specifications VVW-H-171 E &A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69& SP-58, Type 10. . Maximum Temperature: 650°F(343°C) -er• Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts -- "' in place of a knurl nut. y Order By: Figure number and pipe size +r F. Designed to meet or exceed requirements of FMDS2-0. « '= Fig.200 Fig.200C Fig.200E si' Pipe Size Rod Size A B Approx.Wt./100 ' Part No. in. (mml in. (mm) in. (mm) lbs. (kg) ', • 200-1/2 1/2" (15) 3 1 /8 16 3/8" (79.41 25/8" (66.7) 11 (5.0) 200-5/4 3/4" (201 3 " t /3 16 3/e (79.4) 21l2" (63.5) 11 (5.0) 200-1 1" (25) 3/8"-16 33/8" (a5.7) 25/8" (66.71 12 (5.5) 200-11/4 11/4" (32) 3/a'-16 33/4" 194.0) 27/8" (73.0) 13 (5.9) 200.11/2 11/2" (40) 3/8"-16 37/8" 198.4) 27/8" 173.0) 14 (6.4) 200-2 2" (50) 3/8"-16 41/2" (114.3) 3" (76.3) 15 (6.91 -4 200-21/2 21/2" (65) 3/8"-16 55/8" (142.9) 41/8" (104.71 27 (12.3) 200-3 3" (75) 3/8" 16 57/8" 1149.1) 4" (101.6) 29 (13.3) 200-31/2 31/2" 190) 3/e"-16 73/8 (15.6) (187.31 51/4" (133.3) 34 Fig.200S 200-4 4" (100) 3/8"-16 73/8" (187.3) 5" (127.0) 35 116.0) 200-5 5" (125) 1/2"-13 91/e" (231.81 61/4" (158.71 66 (30.2) 200-6 6" (150) 1/2"-13 101/8" (257.2) 63/4" (171.4) 73 (33.4) 200-8 8" (200) 1/2"-13 131/8" (333.41 83/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions B_Ll ne 21 by IF.T.IN Upper Attachments Fig. 78-All Steel Ceiling Plate Size Range: 3/8"-16 rod OTQLCO c Material: Pre-Galvanized Steel D A _ c �L us LISTEDFunction: Attachment to wood beams, ceilings, metal decks or walls. Can also be welded to steel beams. Approvals: Underwriters Laboratories Listed in the USA (UL) -� and Canada (cUL).Additionally UL has listed the Fig. 78 with E fasteners as shown in the table below. Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. o (2 Holes) / r Order By: Figure number, rod size and finish Patent#5,702,077 UL Listed Fastener Table Pipe Size Uty Fastener Type 1/2 -2" 2 #14 x 11/4"A-point hex-washer-head sheet metal screw Material 21/2"-4" Woad 2 1/a"x 11/2"wood screws* Wood 1/2 -2 2 1/4"x 1'tek screws Metal(18 gauge) /2 '2" 2 #14 x I1/4"A-point hex-washer-head sheet metal screw 1/2"-7 2 #14 x 2"A-point-hex-washer-head sheet metal screw Wood *No pre-drilling Wood thru /e gyp board Larger pipe sizes can be hung with reduced spacing. Part Na. Pipe Size A 8 C Hole Dia. D Thread Size Approx.Wt./100 in. Imm) in. (mm) in. (mm) in. g (mm) in. (mm) E a�i 78-3/8 1/2« 2" (15-60) 3" (76.2) 21 1 Lbs. 6.8) /8" (54.01 1 /8' (28.6) 5/t6' 17.91 3/8"•16 15 (6.8) a Fig. 51 - Side Beam Bracket for NFPA Rod& Fastener Sizing a z Size Range: 3/8`-16 thru 1/2"-13 rod, 1/2"(15mm) thru 8"pipe (200mml Hole 1 a Material: Steel Function: Recommended for attaching hanger rod to side of beams or walls. Designed to accommodate current rod schedule and fastener requirements per A Hole National Fire Protection Association (NFPA) Pamphlet 13. Approvals: Underwriters Laboratories Listed in the USA(UL)and / Canada (cUL), and Factory Mutual Engineering approved. / 9 `\ Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Figure number and finish A C C UL US "A' ':. s . LISTED ....a." " Part No. Pipe Size Rod A in. Size B C Hole 1 Hole 2 Size in. (mm) in. Approx.(kg))/100 51-1/2-2 1/2"-2" (15-60) 3/8"-16 2" (50.8) 3/4' (19.0) 2' (mm) i itn. Imm) i16 (mm) Lbs. .9 51-21/2-4 21/2'-4" (65-10o) 3/8"-16 2,. (50.8) /16" (11.1) 7/16" (11.11 35 (15.4) 51-5-6 (50.8) 3/4" (19.0) 2" 150.8) 9/16" (14.31 1fis" (11.1) 34 (15.4) 5'-6" (125-150) 1/2"-13 21/2` 63.5) 51-8 ( 3/4" 119.01 21/2" (63.5) 9/16" (14.3) 3/16" 114.31 71 (32.2) 8" (2001 1/2"-13 21/2' (63.5) 3/4" (19.0) 21/2" (63.5) 11/ts" (17.51 9/16' (14.3) 70 (31.7) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified, Fire Protection Solutions pp 83 p-l.ine by E:T•N Upper At tachments tfiachments 1 Fig.58-Threaded Side Beam Bracket 0 TOLCO Size Range: 3/8"-16 rod, pipe sizes 1/2'(15mm)thru 4" (10omml Material: Pre-Galvanized Steel C 0 us LISTED Function: Practical and economical bracket used to support piping from wood, concrete or steel beams. Features: Unique design allows rod to be easily threaded into bracket. Offset design permits unlimited rod adjustment. Center mounting hole will accept 3/8'and I/2 fastener bolts. Per NFPA 13: 1/2•(15mm)thru 2"(50mm)pipe requires 3/8"fastener, 21/2"(65mm) thru - B 4"(loomm)pipe requires 1/2"fastener.* / Approvals: Underwriters Laboratories Listed in the USA(UL)and Canada (cUL), and Factory Mutual Engineering approved thru 4"(100mm)pipe. titt.tFinish: Pre-GalvanizedNo Order By: Figure number and finish 4)► Vlb: 44 *Note: Additionally UL has listed the Fig. 58 with fasteners `� as shown in table below. 2.1/4"a 2"Lag Bolts (No Pre-Drilling C Up to 4"1100mm)pipe .�,�'' Per NFPA ;" 1 1•3/9"or t/s"Lag Bolts Up to 4"(100,nm)Pipe 2-p16x2" Drive Screws 1 1/2"(15mm)•4"(100mm)pipe (, 0. st yg V a T) a a D 2-N14x 1" Tek Type Screws Into Min.16 Gauge Steel UL Listed Fastener Table Up to 4"(100mm)pipe Pipe Size Qty Fastener Type Material Bolt&Hex Nut 2" 2 #16 x 2"Drive screws Wood Up to 4 (1BOmtn)pipe • 2" 1 3/8"Lag bolt Wood 21/2"-4" 1 1/2"Lag bolt Wood ii 31/2" 2 1/4"x 11/2"Lag bolts Wood J; 4' 2 1/4"x2"Lag bolts'"' Wood i O 4" 2 1/4"x 1"Tek screws Metal(15 gauge) l° 4" 2 1/4"x 1'Tek screws Metal(16 gauge) **No pre-drilling Larger pipe sizes can be hung with reduced spacing. Part No. Pipe Size Rod A B C Approx.Wt./100 in. limn) Size in. (mm) in. (mull in. (nun) Lbs. (kg) 58 1/2"-4" (15-100) 3/8"-16 23/4" (69.8) 11/2" (38.1) 11/e" (28.6) 14 16.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection SolutionsEl -Line 85 by EA=IS Pipe Clamps B3373- Standard Riser Clamp (TOLCO Fig.6) QTOLCo B3373C - PVC Coated Standard Riser Clamp (TOLGO Fin.6PVC) Size Range: (63373) 1/2"(15mm LIST thru 30" {76omm) pipe C S US (B3373C 1/2"(15mm) thru 6' U5 eB IOrnm) pipe Material: Steel FM Function: Used for supporting vertical piping. Design Load Approvals: Underwriters Laboratories Listed in the USA(UL?, Canada (cUL) ) 3/a"(20mm)-g'(200mm). Factory Mutual Engineering Approved, 3/4"(20mm) thru j 8" (2oomm). Conforms to Federal Specification WW-H-171 E &A-A-1192A, Type 8, and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, Type 8. I 11 Maximum Temperature: 650°F(343°C) `" )1 ift Finish: Plain. Contact B-Line for alternative finishes and materials. / A_ Order By: Figure number, pipe size and finish, wilt Size ;11111111� �` Designed to meet or exceed requirements of FM DS 2-0. ) L Bolts and Nuts Included .f r "{ KJ 83373C Pipe Size L Approx.Wt./100 Part No, in. (mml in. (min) Bolt Size Lbs. (kg) B3373-1/2 1/2" (15) 9" 1228.61 3/8"-16811/4" 101 (45.91 B3373-3/4 3/4" (20) 91/4" (234.9) 3/r-16811/4" 105 (47.7) B3373-1 1" (25) 99/1e" (242.91 3/8"-16x 1ya' 109 149.4) Notes: For ductile iron B3373-11/4 11/4" (32) 10" (254.0) 3/s"-16x 11/4" 112 (50.9) (DI)pipe use part 83373-11/2 11/2" (40) 101/4" (200.3) 3/8'"-16 x 11/2" 113 151.1) number zContact B-Line size.Contact B-Line a B3373.2 2" 1501 103/4" (273.0) 3/t"-16x 11/2" 165 (75.01 Engineering for more at B3373-21/z 21/2" (651 111/4" 1285.7) 3/"-16x 11/2" 180 (81.6) information. a. B3373-3 3" (801 11t5/16' 1303.2) 3/8"-16 x 11/2" 195 (88.41 n B3373-31/z 31/2" (90) 123/8" (314.3) 1/2"-13 x 13/4" 217 (98.5) 83373-4 4" (100) 127/8" (327.0) W-13813/4" 228 (103.5) 63373-5 5" (125) 14" (355.6) 1/2"-13x 13/4" 480 (2t7.7) For larger sizes,consult B3373-6 6" 1150) 153/16" (385.8) 1/2"-13x2' 526 (238.6) catalogthe full line pipe hanger B3373-8 8" (200) 173/4' (450.8) 5/8"-11 x21/2" 957 (434.1) 83373-10 10" (250) 197/16" (493.7) 5/8"-11 x21/2" 1101 (499.4) B3373-12 12" (300) 2111/16" (550.91 3/8'"-11 x3" 1622 (735.7) 83373-14 14" (350) 233/4s" (598.5) 5/8"-11 x3" 1732 (785.6) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions B Line 29 tPr ,-.1;,.1"t'-° CPVC Clamps TOLCO' Fig. 22- Hanger for CPVC Plastic Pipe& IPS Steel Pipe Single Fastener Strap O US Size Range: 3/4'(20mm)thru 2"(50mm) CPVC pipe LISTED Material: Pre-Galvanized Steel c Function: Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems.The product acts as a hanger when tab is upward and the fastener screw is in the horizontal position. Fig.22 can be installed on the top of a beam, but in this situation acts as a guide to the 7/ piping which is supported by the beam itself. It is not intended to support CPVC pipe from under a flat horizontal surface, such as a ceiling. Approvals: Underwriters Laboratories Listed in the USA(UL)and Canada (cUL)to support fire sprinkler piping. May be installed in wood using fasteners supplied with product,or into minimum 20 gauge(0.9mm)steel using (11 1/4'x 1'tek type screw. Meets and exceeds the requirements of NFPA 13, A 13R and 13D. Features: Fig.22 incorporates features which protect the pipe and ease ► B installation.ni The filyred edge design gs t CPVC pipe frusing any rough surface. It is easily attached to the building structure using the special UL Listed hex head self threading screw*furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment to be used as installation tools. No impact tools (such as a hammer)are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish: Pre-Galvanized Order By: Figure number and pipe size. yp * Hardened hex head self threading screw is furnished with the �L y product and is the minimum fastener size acceptable. CPVC Max.Hanger Fastener Hex Approx. Pipe Size A B C Spacing Head Size Wt./100 Part No. in. (mm) in. (mm) in. (mml in. Imml Ft. (ml in. Imm) Lbs. (kg) 22-3/4 3/4' (20) 27/it (61.9) 15/it (33.3) 13/16" (30.2) 5'-6" (1.67) 5/16" (7.9) 9 (4.1) 22-1 1" 125) 211/16- (68.3) 17/16" (36.5) 13/16" (30.2) 6'-0" (1,83) 5/18" (7.9) 9 (4.1) 22-11/4 11/4° (32) 31/16' (77.8) 15/8" (42.3) 13/16' (30.2) 6'-6" (1.98) 5/16" (7.9) 11 (5.0) 22-11/2 11/2" (40) 35/16" 184.1) 13/4" (44.4) 13/16" (30.21 7'-0" (2.13) 5/16" (7.9) 12 (5.4) 22-2 2" (50) 33/4' 195.2) 21/8" (54.6) 13/it" (30.2) 8'-0" (2.44) 5/1s" (7.9) 15 (6.8) Reduced Spacing For IPS Pipe ,ti 0e IPS Max.Hanger Pipe Size Spacing 1 Part No. in. Imm) Ft. (m) �:t 22-3/4 3/4" (20) 1'-9" (1.67) 22-1 1" (25) 1'-10" (1.83) 22-11/4 11/4" (32) 2-4" (1.98) 22-11/2 11/2' (40) 2-9" (2.13) 22-2 2" (5o) 3-6" (2.44) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 32 B-Line series Fire Protection Solutions CPVC Clamps TOLCO'Fig.22L2- One Hole Hanger/Restrainer for CPVC& Steel Pipe Size Range: 3/4'(20mm)thru 2"(50mm)CPVC&steel pipe C CL us LISTED Material: Pre-Galvanized Steel Function: cULus Listed to perform as a hanger and restrainer for CPVC or IPS ^'_.j'� piping systems.The innovative design also allows for a preferred installation /, " C. location close to a CPVC fitting without applying damaging compression forces /i/ (i) \. on the pipe which could result in serious Mechanical ESC(Environmental /i i \ Stress Crackin I. i 9 , A Approvals: Underwriters Laboratories Listed in the USA(UL)and Canada ! /� (cUL)to support fire sprinkler piping. Can be installed in wood or into mini- j, ter" mum 20 gauge(0.9mm)steel using(1) 1/4"x 1"tek type screw. Meets and !/ ��% exceeds the requirements of NFPA 13, 13R and 13D. . i Installation Note: Comes in open position for easier installation. Because of II 1�,., multi-structural installation possibilities, specific fastener not included;see li notes below for various applications. II For Concrete Installation—UL requires a minimum test load of 340 lbs for \\ CPVC hangers and 750 lbs for steel pipe hangers;verify anchors meet or exceed these requirements. i For Wood Installation—#14 x 11/2" wood screws will support the required a load for cULus. For Steel Installation—1/4" x 1" (min.20ga steel)Tek type screw will support required UL load. Finish: Pre-Galvanized Order By: Part number Patent Pending . 't"A, ,ii: I Mounting = * Surface r ", r„ .f Tab Down 11 Hanger/Restrainer or Tab Up 4--.::r: jl WI' t f ii Sprinkler ;;; 1—! Head Pipe OD I . ;:,,,':. ."''7.'.:.-''.:.:,' Teri , w r J. Offset + ' Design `� ,'- 1' . s Hanger/Restrainer ze Fitting .� F Ai • ',` "i OD CPVC or Steel Max.Hanger Max.Hanger Approx. Pipe Size A B C Spacing-CPVC Spacing-Steel Wt./100 Part No. in. (mm) in. (mm) in. Imml in. Imml Ft. (in) Ft Im) L6a. (kg) 2212-3/4 3/4' (20) 23/it(55.6) 15/I6"(23.8) 3/4' (19.0) 51/2 (1.67) NA (NA) 9 (4.1) 22L2-1 1" (25) 21/2- (63.5) 11/6' (28.6) 3/4 (19.0) 6 (1,83) 12 (3.66) 9 (4.1) 2212-11/4 11/4" (32) 213/16"171.4) 11/4" (31.7) 3/4" (19.0) 61/2 (1.90) 12 (3.66) 11 (5.0) 22L2-11/2 11/2" (40) 31/a" 179.41 17/16'(36.5) 3/4" (19.0) 7 (2.13) 15 (4.57) 12 (5.4) 2212-2 2" (501 39/18 (90.5) 15/8 (41.3) 3/4" (19.0) 8 (2.44) 15 (4.57) 15 (6.8) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Fire Protection Solutions 33 Eaton CPVC Clamps TOLCOTM Fig.23- Hanger for CPVC Plastic Pipe&IPS Steel Pipe Double Fastener Strap(B-Line B3182) CO us Size Range: 3/4'120mm)thru 3"(80mm)CPVC pipe LISTED Material: Pre-Galvanized Steel Function: Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. Fig.23 can be installed ,' on the top,bottom or side of a beam. ,' Approvals: Underwriters Laboratories Listed in the USA(UL) and Canada(cUL)sizes 3/4"(2omm)thru 2"(5omm)to support fire sprinkler piping. May be installed in wood using fasteners supplied with product,or into minimum 20 gauge(0.9mm)steel using(2) 1/4"x .- -I:10 1"tek type screw. Meets and exceeds the requirements of NFPA 13, 13R and 13D. \ B Features: Fig.23 incorporates features which protect the pipe ) `and ease installation.The flared edge design protects the CPVC en. / pipe from any rough surface. It also incorporates snap restrainers e A allowing easier and faster installation. Easily attaches to the building c structure using the two UL Listed hex head self threading screws* furnished with the product.It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer)are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required Finish: Pre-Galvanized ik't - ,,- - Order By: Figure number and pipe size �'„ * Hardened hex head self threading screw is furnished with the ;'"- .,. product and is the minimum fastener size acceptable. 4.. CPVC Max.Hanger Fastener Hex Approx. Pipe Size A B C Spacing Head Size Wt/100 Part No. in. (mm) in. (mm) in. (mm) in. (mm) Ft. (m) in. Imm) Lbs. (kg) 23-3/4 3/4" 120) 31/8" (79.4) 13/16" (39.7) 13/16' (30.2) . 51/2 11.67) 5/it (7.9) 9 14.1) 23-1 1' (25) 33/8" (85.7) 111/16" 142.9) 13/16' (30.2) 6 (1,83) 6/16" (7.9) 9 14.1) 2341/4 11/4" (321 43/16"(106.4) 23/32" (53.1) 13/16" (30.2) 61/2 11.98) 5/16" (7.91 11 15.0) 23-11/2 11/2" (40) 47/16' (112.7) 27/32' 156.3) 13/16" (30.2) 7 12.13) 5/16' (7.9) 12 (5.4) 23-2 2" (50) 47/8" (123.8) 27/16' 161.91 13/1f (30.2) 8 12.44) 5/16" (7.9) 15 (6.8) 23-21/2 21/2' 165) 53/8 (136.51 213/46" (68.31 13/16" (30.2) Consult Factory 5/16" (7.9) 22 (10.0) 23-3 3" (80) 6" (152.41 3" (76.2) 13/1s" (30.2) Consult Factory 5/1s" (7.9) 25 (11.3) c" Reduced Spacing For IPS Pipe IPS Max.Hanger Pipe Size Spacing Part No. in. (mm) Ft. (ml 23-3/4 3/4" 120) 1'-9" (1.67) 23-1 1" (25) 1'-10" 11.83) 23-11/4 11/4" (32) 2-4" 11.98) 23.11/2 11/2" 140) 2-9" (2.13) 23-2 2" (50) 3-6" (2.44) 23-21/2 21/2" (65) Consult Factory 23-3 3' (80) Consult Factory All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 34 B-Line series Fire Protection Solutions — CPVC Clamps TOLCO'"Fig.24-Hanger for CPVC Plastic Pipe&IPS Steel Pipe Double Fastener Strap Side Mounted IB-Line B3183) hlli Size Range: 3/4"(20mm)thru 2"(50mm)CPVC pipe GC USIE6 Material: Pre-Galvanized Steel Function: Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems.Can be installed on the top or on the bottom c - of a beam. Approvals: Underwriters Laboratories Listed in the USA(UL)and Canada(cUL)to support fire sprinkler piping. May be installed in wood using / fasteners supplied with product, or into minimum 20 gauge(o.912mml steel using(2) 1/4"x 1'tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. II ;, Features: Fig.24 incorporates features which protect the pipe and , ease installation.The flared edge design protects the CPVC pipe from any rough surface.Easily attaches to the building structure using the [ °, two UL Listed hex head self threading screws'furnished with the y product. It is recommended that rechargeable electric drills fitted with : 2' a hex socket attachment be used as installation tools. No impact 4,t ," tools(such as a hammer)are allowed. Damage has been known to ":" '; O result from installations using impact type tools.No pre-drilling of a " pilot hole in wood is required. 3 ,t r y B Finish: Pre-Galvanized > B�... Order By: Figure number and pipe size -- i ----_________,` " Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. CPVC Max.Hanger Fastener Hex Approx. Pipe Size A B C Spacing Head Size Wt/100 Part No. in. (mm) in. Imm) in. (mm) in. (mm) Ft (m) in. (mm) Lbs. (kg) 24-3/4 3/4" (20) 25/i6" (58.71 15/32" (27.8) 13/16" 130.21 51/2 (1.67) 5/16" (7.9) 9 (4.1) 24-1 1" (25) 25/8" 166.7) 15/16" (33.3) 13/16" (30.2) 6 (1.831 5/16" (7.9) 9 (4.11 24-11/4 11/4" (32) 3" 176.21 11/2" (38.1) 13/16" (30.21 61/2 (1.98) 5/16" (7.9) 11 (5.0) 24-11/2 11/2" 1401 31/4" (82.5) 15/8' 142.3) 13/16" (30.2) 7 12.13) 5/16" (7.9) 12 (5.4) 24-2 2" (50) 311/16" (93.7) 127/32" (43.6) 13/16" (30.2) 8 (2.44) 5/i6" 17.9) 15 (6.81 Reduced Spacing For IPS Pipe IPS Max.Hanger Pipe Size Spacing Part No. in. (mm) Ft. 1m) 24-3/4 3/4" 120) 1'-9" (1.67) 24-1 1" (251 1%10" 11.83) 24-11/4 11/4" (32) 2-4" (1.98) 24-11/2 11/2" (40) 2-9" (2.13) 24.2 2" 1501 3-6" (2.44) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. 13-L — — ine series Fire Protection Solutions 35 Eaton CPVC Clamps TOLCOTM Fig.27B -Speed Nut Size Range:—Fits screws supplied with all CPVC hangers. Material:—Steel Finish:—Pre-Galvanized(Zinc) Function:—To be used anywhere a screw cannot achieve full embedment due to thickness of wood structural material when installed. Fig.27B allows full pull out load capacity of screws when installed to the standard screws supplied with all CPVC /;?....4:(0°11111° hangers(Fig.22, Fig.22L2, Fig.23, Fig.24, Fig. 28,Fig.28M. Fig.29,and B3184). Approx.Wt.M00 Part No. lbs. (kg) `' 27B 1.2 (0.5) ` Fig.27B (1)Required High n--1 R9.27B Side of Hanger 1 i (2)Required n—T Application ri I I u n I 1 1 II ta n I 11 u I , 11 �i i'1•• ( , Ir 1 1 n 11 1 n 1 I 11 1 N ., n ' r I 1 '1\ r n I I —��11I `III 1 ,�t(/7IIIp,1 ,- -'- n ' 1• n u I u I u n II 11 u_JI Hanger Application Hanger and Restraint Application • a�-_.\ y I it 1 j 5 I l�-\ 1�11 (I( 1'(L- Ir-n I If 1\ r / II a I 1'\ ,Id 1 II II 1 p\. q I u II 1 ; / n u 1 •- I u u 1% : . r r it II uII u u II \ 11 II i n u 4. II 11 `�vVj •�. Fig.27B Q.tt��,,�� n .W�. , •. u n '\$.�4. `'^ `\�$ .` ii ii (2)Required n 111 II \ -, 111 II \ !II II \ n 111 II \ •II 11 \ 11 II \``\ lit it Fig.27B `\ n lit n '` in a (1)Required High Side of ' V I" ' 'a e �'\\\, 1n 0 Hanger Application '\\ O (ii it \ 111 11 '\ :it n it it n u I n n n u u u a u n n n u u n n e II e n n II 11 11 II iLy 11 II Hanger Application Hanger and Restraint Application NI dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 36 B-Line series Fire Protection Solutions AIN CPVC Clamps TOLCO'Fig.28-"Stand-Off" Hanger&Restrainer for CPVC Plastic Pipe &IPS Steel Pipe Size Range:—3/4"(20mm)through 2'(50mm) CO us Material:—Steel, Pre-Galvanized LISTED Function:—Designed to be used as a hanger and restrainer for CPVC piping where the'standoff"design will ease installation by eliminating the need for wood blocking. if& 1 Features: • Flared edge design protects CPVC pipe from any rough or abrasive surfaces. IAN.° •Unique twist and lock design holds pipe firmly in place and allows retrofit type of installation. •The"Stand-Off'design eliminates the need for wood block extension. •Can be installed on horizontal or vertical piping regardless of mounting surface orientation. III•Attaches easily to wood structure with two hex head self-threading screws furnished with A product. •Installs easily using rechargeable electrical driver with 5/16'(7.9mm)extension socketB eliminating impact tool damage to pipe. y •Attaches easily to steel, minimum 18 gauge (1.024mm)with(2) 1/4'x 1'tek type self drilling tapping screws. • UL Listed as a hanger and a restrainer for fire sprinkler piping. Approvals:—Underwriters Laboratory Listed in the USA(UL)and Canada(cUL)to support automatic fire sprinkler systems. May be installed into wood using fasteners /'-': supplied with product,or into minimum 18 gauge steel using(2) 1/4"x 1'tek type y ; screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D.Fig.28 satisfies 4/ the UL vertical restraint requirement where needed. UL Listed as a hanger and vertical restraint when installed on 3/8'(9.5mm)composite wood material. Use two Fig.276 (page 36) b _ Speed Nuts when used as a hanger and restraint. Use one Fig.27B Speed Nut on the upper installed screw when used as a hanger only. Order by:—Figure number and pipe size. l Pat.#7,455,268, Pat.#7,832,248 �I� •� �il k ..... Fig.276 1 Fig.27B fl It)Required High (2)Required 1 1 7'''`'t Side of Hanger L Application i •-_-: Cl I . fl Li � Hanger Application Hanger and Restraint l ::;w Application / ` ' CPVC A B C Max Hanger Approx. I 1 - Pipe Size Spacing Wt./100 I Part No. in. (mm) in. (mm) in. (mm) in. (mm) Ft. (m) lbs. (kg) :4428-3/4 3/4' (201 31/32' (77.0) 2' (50.81 31/2' (88.91 51/2 (1.67) 18 (8.1) /� 28-1 1' (25) 35/16' (84.1) 23/16' (55.6) 31/2" (88.9) 6 (1.83) 21 (9.5) 28-11/4 11/4 (32) 35/8" (92.1) 23/8 (60.3) 31/2' (88.9) 61/2 (Imo 23 (10.41 28-11h 11/2' (40) 4' (101.6) 21/i (63.5) 31/2" (88.9) 7 (2.131 31 (14.01 - o) 28-2 2" (50) 41/2" (114.3) 2t1/16'(68.3) 35/8' (92.1) 8 (2.44) 34 (15.4) eo Reduced Spacing For IPS Pipe ••, IPS Max.Hanger .f' U Pipe Size Spacing •-- ;--,- Part No. in. (mm) Ft. (m) 28-3/4 3/4" (20) 1'-9" 11.67) el 28-1 1" (25) 1'-10" (1.83) l '.-'1 28-13/4 11/4' (32) 2-4" 11.98) 28-11h 11/2- (401 2-9" (2.13) '-;`"�.,•' i - 28-2 2' (50) 3-6" (2.44) `' ,rr: All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. 8-Line series Fire Protection Solutions 37 Eaton CPVC Clamps TOLCO'' Fig.28M - Offset Hanger& Restrainer for CPVC Plastic Pipe and IPS Steel Pipe Size Range: 3/4'(20mm)thru 2'(32mm) CC)US Material: Steel, Pre-Galvanized LISTED Function: Designed to be used as a hanger and restrainer for CPVC piping or steel piping where the "stand-off" design will ease installation by eliminating the need for wood blocking. Features: .._ : \\ •Flared edge design protects CPVC pipe from any rough or abrasive surfaces •Unique snap-on design holds pipe firmly in place and allows retrofit type of installation i \ 1 •The "Stand-Off" design eliminates the need for wood block extension •Can be installed on horizontal or vertical piping regardless of mounting surface orientation A I •Attaches easily to wood structure with two hex head self-threading screws furnished with product , •Installs easily using rechargeable electrical driver with 5/16" (7.9mm)extension socket eliminating impact tool damage to pipe •Attaches easily to steel, minimum 18 gauge(1.024mm)with(2) 1/4"x 1"tek1. drilling tapping screws type self c 1 •(cULus)Listed as a hanger and a restrainer for fire sprinkler piping Installation Note: When installed in wood structural members and threads from the 6 #10 x 1'screws are exposed, use Fig.27B(page 36)speed nut to secure Approvals: Underwriters Laboratory Listed in the USA(UL)and Canada(cUL) to support automatic fire sprinkler systems. • May be installed into wood using fasteners screws. ► Meets and exceeds the requirements of NFPA 13, t 13R and 13D.Fig.28M satisfies the UL vertical 3 restraint requirements where needed. Order By: Figure number and pipe size Patent#7,744,042 rf • - r 44 . kli a ----Tr — ,. e • e 3 d r , 4 e n 01 -11 i Restraint ET-, '"" I r Fig.276 I �— a (2)Required Restraint i -, CPVC Pipe Size A Hole Dia.B C Max Spacing* Approx.Wt/100 : a _) Part No. in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) lbs. (kg) 28M-319 3/4" (201 2' (50.8) 3/t6' (4.81 35/16' (84.1) 5'-6" 11676) 9 (4.1) . " 28M-1 1' (251 21/s" (54.0) 3/16" (4.8) 31/2' (88.9) 6'-0" 11829) 12 (5.4) 28M-11/4 11/4" (32) 25/16" (58.7) 3/16' (4.8) 31/f (88.9) 6'-6" (19811 13 (5.9) Hanger and Restraint 28M-11/z 11/2" (49) 27/16 (61.9) 3/16" (4.81 37/s" (98.4) 7"-0" (21331 14 (6.3) Application a' 28M-2 2' (50) 25/8" (66.7) 3/16" (4.8) 47/16" (1127) 8"-0" (2438) 15 (6.8) .;, ` Required per NFPA 13 for CPVC plastic pipe 3 F0 H Reduced Spacing For IPS Pipe (1)Requ e d IPS Pipe Size Max.Hanger Spacing High Side of Hanger Part No. in. (mm) Ft. (ml i ---- 28-3/4 3/4" (20) l'-9" (1.67) 28-1 1• (25) 1-10" (1.83) Detail A 28-11/4 11/4" (32) 2-4" (1.98) Hanger Application 28-11/2 11/2' (401 2-9" (2.13) 28-2 2" (501 3-6" (2.44) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 38 B-Line series Fire Protection Solutions CPVC Clamps TOLCO'"Fig.29-Double Offset Hanger&Restrainer for CPVC Plastic Pipe& IPS Steel Pipe Size Range: Available in 3/4"(20mm)and 1'(25mm)pipe sizes COOS Material: Pre-Galvanized Steel 1.5- LISTED (xrmu) Function: Intended to perform as a hanger and restrainer for CPVC, plastic fire sprinkler '=;,,IF pipe.Provides double offset 11/z" (20mm)x 11/2" (20mm)from mounting surface.This 1) design will ease installation by eliminating the need for wood block extension and allow retro-fit attachment of hanger to sprinkler pipe. Features: ®i. 179.1mm1 •Thumb tab provides protection to restrain pipe in rough job site conditions.Tab dO O O 1 is not required to be bent for listed installation. 0 1 •Offset edge eliminates abrasion. 0 •Attaches easily to wood structure with two special#10 x 1" hex head self-threading screws furnished with product. o •Can be used as a single offset hanger by aligning"dimples'with top of mounting surface and utilizing two fasteners in two of the three holes provided. Approvals: Underwriters Laboratories Listed in the USA(UL)and Canada(cUL)as a hanger and restrainer to support fire sprinkler systems. Meets and exceeds requirements of NFPA 13, 13R and 13D. Finish: Pre-Galvanized Order By: Figure number and pipe size. Patent#US2008/0129040A1 't t CPVC Max Hanger Approx. s o Pipe size Spacing Wt./100 Part No. in. (mm) Ft. (m) lbs. (kg) +r o 29-3/4 3/4' 1201 V-6" (1.67) 18 (8.1) O 0 0 0 _ 29-1 1" (25) 6"0" (1.83) 19 I8-61 , t.Imm' rA ) Reduced Spacing For IPS Pipe IPS Max.Hanger :` Pipe Size Spacing Part No. In. (mml Ft (m) gum) 29-3/4 3/4" (20) 1'-9" (1.67) 29-1 1" (25) 1'-10" (1.63) e o i1 •O , �1®0 ex • • U ® T L,V'- Double Offset Single Offset Install using a rechargeable electric drill fitted with a 5/16" 17.9mm)socket attachment with the special hex head self-tapping screws provided.Install screws until they bottom out. Pipe can be "snapped" into hanger before or after installation of the screws to the mounting surface. "Thumb tab" may be bent up to provide additional protection to the pipe,but is not required for performance of the hanger/restrainer function. Al)dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Fire Protection Solutions Eaton Seismic Bracing TOLCOTM Fig. 4L- Longitudinal "In-Line" Sway Brace Attachment Size Range: 2"(5omm)through 8"(200mm) IPS. 0 UL trs Material: Steel LISTED Function: For bracing pipe against sway and seismic disturbance. Set Screw&Hardware �� Approvals: Underwriters Laboratories Listed in the USA(uL►and Included ��,, -trio `t..). Canada(cUL)21/2'(65mm) through 8"(200mrn) pipe. Approved by Factory Mutual 6Engineering (FM), 21/2"(65mm) through 8"(200mm)pipe. 1 Installation Instructions: Fig. 4L is the"braced pipe'attachment component of a longitudinal sway brace assembly. It is intended to be combined with the "bracing pipe"and TOLCO structural attachment D A component to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. rn To Install: Place the Fig. 4L over the pipe to be braced and tighten bolts. Then engage'bracing pipe'into jaw opening and tighten set screw until head snaps off. Jaw attachment can pivot for adjustment to proper 11)_4_ m brace angle. r E NFinish: Plain. Contact customer service for alternative finishes and materials. Order By: Figure number, pipe size and finish. it "fir;.. \„ i� Longitudinal 4-Way Riser BraceIR I; -'' Brace (plan view) nF . Pipe Max.Horizontal Approx. Part Size A C D Bolt Size Design Load(cULuc) Wt./100 No. in. (mml in. (mm) in. (mm) in. (mm) lbs. (kN) lbs. (kg) 41-21/2 21/2" (65) 6/16' (163.5) 21/2" (63.5) 23/4' (69.8) 1/2"-13 2015 18.96) 253 (114.7) 41-3 3" (80) 7" (177.8) 23/4" (69.8) 31/16 (77.8) 1/2"-13 2015 18.96) 268 (121.5) 4L-4 4" 1100) 81/2" (215.9) 33/8" (85.7) 311/16" (93.7) 1/2"-13 2015 (8.96) 348 (157.81 41-5 5" (125) 93/4" (247.6) 37/8" (98.4) 43/s" (111.1) 1/2"-13 2015 (8.96) 380 (172.3) 4L-6 6" (150) I11/z"(292.1) 5' (127.0) 51/s" (130.2) 1/2"-13 2015 (8.96) 640 1290.3) 41.-8 8" (200) 131/4'(336.5) 55/8' (142.8) 55/8" (142.8) 1/2%13 2015 (8.96) 728 (330.2) 1 Pipe Max.Horizontal ' Max.Horizontal Design Load IFM) Pan Size Design Load(cULuc) 30-44° 45-59° 60°-74° 15°-90° ° The loads listed rac are exial No. in. (mnt) Jl1 Ibs./(kNl horizontal lbs./(kN) lbs./(kN Ibs kN loads ont the deap.The tal load capacity, H. of 4L-21/2 21/2" (65) ' 2015(8.96) 1030 14.58) 118015.24) 1420(6.31) 1590(7.07) the brace is: H = F x sin ?, 4L-3 3" (80) 201518.96) 1030(4.58) 1180(5.24) 1420 16.311 1590(7.07) where ? the installation angle measured om the vertical. 4L-4 4" (100) , 2015(8.96) 53012.36) 73013.25) 890(3.96) 990(4.40) FM approved when used with 4L-5 5" (125) - 2015(8.96) 530(2.36) 730(3.25) 890(3.96) 990(4.40) 1', 11/4", 11/2"or 2"Sch.40 4L-6 6" (150) ' 2015(8.96) 530(2.36) 730(3.25) 890(3.96) 990(4.40) brace pipe. 4L-8 8" (200) 2015(8.96) 490 12.18) 680(3.02) 830 13.691 930(4.13) Eaton's B-Line series seismic bracing components are designed to be compatible only with other B-Line series bracing components, resulting in a listed seismic bracing assembly. Eaton B-Line Division warranty for seismic bracing components will be the warranty provided in Eaton B-Line Division standard terms and conditions of sale made available by Eaton. except that, in addition to the other exclusions from Eaton B-Line Division warranty, Eaton makes no warranty relating to B-Line series seismic bracing components that are combined with products not provided by Eaton. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. R-Line serios Pipo Hangers&Supports - - - -- - -- - - 174 Eaton Seismic Bracing TOLCO"' Fig, 4LA- Longitudinal "In-Liner Sway Brace Attachment Size Range: 1"(25mm)through 12'(300mm) IPS. C ST u541> Material: Steel LISTED -�" Function: For bracing pipe against sway and seismic diSturbance. Approvals: Approved by Factory Mutual Engineering (FM), 1'(25mm) through 12"1300mm)pipe. Underwriters LabOratories Listed in the USA and ""� Canada (cULus), 1'125mm)through 10"(250mm)pipe. See allowable loads in \ Charts on page 172. air Installation Instructions: Fig. 4LA can be used as the system attachment . D component of a longitudinal or lateral brace assembly. It is intended to be47; "�/ A t„ combined with the'bracing member"and TOLCO transitional attachment and f . C m structural attachment to form a complete bracing assembly. For fire sprinkler %,___ f3applications NFPA 13 guidelines should be followed. * 1 4 d5. To Install: Place the Fig.4LA pipe clamp component over the pipe to be braced and tighten down the break-off nuts until the hex head portion breaks 4LA-1 thru 4LA-4 ra off to verify correct installation torque. Next engage brace member(pipe or strut) with jaw component and tighten break-off head bolt until the hex head breaks off to verify correct installation torque. Pivot jaw ,. for correct angle and attach to structure using TOLCO brand transitional IR attachment and structural attachment. �,R4s Finish: Plain or Electro Galvanized. Contact customer service ;`. . . it, for alternative finishes and materials. :-„,„ Order By: Figure number, pipe size and finish. 1 A . 4 r C k.,..) ji >i @i '---- �,. 4LA-6 thru 4LA-12 Pipe Part Size A Approx. Bolt Size Wt./100 (aim) in. (mm) Um (kk g) 1 No. in. (mm) in. (mm) in. 4LA-1 1' (25) 319/32" (91.2) 15/16" (33.51 15/16' 133.5) 3/8"-16 119 (54.0) 4LA-11/4 11/4" (32) 329/32" (99.3) 13/8" (35.31 13/8" (35.3) 3/8"-16 123 (55.8) 4LA-11/z 11/2" (40) 45/3z" (105.7) 11/2" (38.5) 11/2" (38.5) 3A1"-16 127 (57.6) 1 4LA-2 2" (50) 511/32" (135.6) 21/32" (51.9) 21/16" (51.9) 3/8'-16 142 (64.4) 4LA-21/z 21/2" (65) 527/32" (148.71 25/16" (58.5) 25/16" 158.5) 3/8"-16 173 (78.5) 4LA-3 3" (801 61/2" (164.9) 25/a" (66.6) 25/8" (66.6) 3/8"-16 187 184.8) 4LA-4 4" (100) 717/72" 1191.31 31/e" (79.5) 31/8" (79.5) 3/0"-16 209 (94.8) 41A-6 6" (150) 105/8" (269.9) 49/16" (115.9) 49/16" (115.91 1/2'-13 521 1236.3) 4LA-8 8" 1200) 1213/16" (325.5) 59/is" (143.7) 521/32" (143.7) 1/2"-13 629 (285.3) 41.A-10 10" (250) 161/2" (419.1) 71/4" (184.2) 71/4" (184.2) 1/2"-13 1320 (598.7) 4LA-12 12" (300) 181/2" (469.9) 81/4" (209.6) 81/4" (209.6) 1/2"-13 1496 (678.6) Eaton's B-Line series seismic bracing components are designed to be compatible only with other B-Line series bracing components, resulting in a listed seismic bracing assembly. Eaton B-Line Division warranty for seismic bracing components will be the warranty provided in Eaton B-Line Division standard terms and conditions of sale made available by Eaton,except that, in addition to the other exclusions from Eaton 13-Line Division warranty, Eaton makes no warranty relating to B-Line series seismic bracing components that are combined with products not provided by Eaton. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 175 B-Line series Pipe Hangers&Supports Seismic Bracing TOLCOTM Fig. 4LA - Longitudinal "In-Line" Sway Brace Attachment cont. DO D1 401 LISTED dongirinni Lateral 0 Brace ••'/ -"---'--- Brace ' , „r. ':`, j� r = 65 3 i L;: o, V m U Longitudinal Loads Max.Horizontal Design Load(FM) Max.Horizontal E M Part Pipe Size ' 30°-44° 45°-59° 75 �' No. in. (mm) lbs. (kN) lbs. (kN) l 6. R 1 N) lbs. (kN) ( Desl lbs. Load) 4LA-1 1" (25) 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) ± 1000 (4.5) 4LA-11/4 11/4' (32) 680 (3.02) 970 14.31) 1190 (5.29) 1320 (5.87) 1000 (4.45) 4LA-11/2 11/2" (40) 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 7 1000 14.45) 41A-2 2" (50) j 680 (3.02) 860 (3.82) 1030 (4.58) 1150 (5.11) ; 1000 (445) 4LA-21/2 21/2" (65) 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) ` 1000 (4.45) 4LA-3 3" (80) 680 (3.02) 970 (4.311 1190 (5.29) 1320 (5.87) 1000 (4.45) 4LA-4 4" (100) 680 (3.02) 970 (4.31) 1190 15.29) 1320 15.87) 1000 (4.45) 4LA-6 6" (150) ( 1620 (7.201 2,260 (10.051 2010 (8.94) 2220 (9.87) 1600 (7.11) 4LA-8 8" (200) 1620 (7.20) 1,660 (7.38) 1570 (6.98) 1740 (7.74) ( 2015 (8.96) 41A-11) 10" 12501 1620 (7.20) 1,660 (7.381 1570 (6.98) 1740 (7.741 ' NA (NA) 4LA-12 12" (300) 1620 17.20) 1,660 (7.38) 1570 (6.981 1740 (7.74) i NA (NA) Lateral Loads Max.Horizontal Design Load(FM) l Part Pipe Size 30 -44 Max.ig Load 1Ua) No. in. Imm) lbs.° DIN) lbs. 5kN) lbs. 7(kN) lbs. �(MN) Des lbs. L0(N)UL) 41A-1 1" (251 I 680 (3.02) 970 (4.31) 1190 15.291 1320 (5.87) i NA (NA) 4LA-11/4 11/4" (32) 680 (3.02) 970 (4.311 1190 (5.29) 1320 (5.87) NA (NA) 4LA-11/2 11/2" (40) 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) NA (NA) 4LA-2 2" (50) 680 13.02) 970 (4.31) 1190 (5.29) 1320 15.87) NA ) 4LA-21/2 21/2' (65) i 680 (3.02) 970 (4.31) 1190 (5.291 1320 (5.871 NA (NA) 4LA-3 (NAI 3" (80) 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) ! 1000 (4.45) 4LA-4 4" (100) 680 (3.02) 970 (4.31) 1190 (5.29) 1320 15.87) 1000 (4.45) 4LA-6 6" (150) 1620 (7.201 2,300 (10.23) 2820 (12.54) 3140 (13.96) 1600 (7.11) 4LA-8 8" (200) $ 1620 (7.20) 2,300 (10.23) 2820 112.54) 3140 (13.96) i 2015 (8.96) 4LA-1D 10" (250) I 1620 (7.20) 2,300 (10.23) 2820 (12.54) 3140 (13.961 NA (NA) 4LA-12 12" (300) . 1620 (7.20) 2,300 (10.231 2820 (12.54) 3140 (13.96) f NA (NA) Eaton's B-Line series seismic bracing components are designed to be compatible only with other B-Line series bracing components, resulting in a listed seismic bracing assembly. Eaton B-Line Division warranty for seismic bracing components will be the warranty provided in Eaton B-Line Division standard terms and conditions of sale made available by Eaton, except that, in addition to the other exclusions from Eaton B-Line Division warranty, Eaton makes no warranty relating to B-Line series seismic bracing components that are combined with products not provided by Eaton. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Pipe Hangers & Supports 176 _. - - Eaton Seismic Bracing TWO' Fig. 906 - Sway Brace Multi-Fastener Adapter Component of State of Size Range: Use with 1"(25.amm)and 11/>!" California OSI IPD Approved UL listed Fig. 900 Series Earthquake Brace Attachments. Seismic Restraints System Material: Steel C0(ISApplication: Allow p greater s sway brace fittings to develop load Carrying ability by providing multiple fastener USTE0 attachments. The National Fire Protection (NFPA) provides H1 information on fastener loads to various structures. Refer to NFPA 13(2010)9.3.5.9.1. I` Approvals: Underwriters Laboratories Listed in the USA g m (UL)and Canada(cUL►only when used with TOLCO Fig. 900 Series Earthquake Brace Attachments. Included in 0our Seismic Restraints Catalog approved by the State of HI rod s• California Office of Statewide Health Planning and 0 `� t9'm Development(OSHPD). For additional load, spacing and co2, placement information relating to OSHPD projects, please C� 1 J j H2 ro refer to the TOLCO Seismic Restraint Systems Guidelines. Installation Instructions: Fig. 906 is a multiple fastener structural attachment component of a longitudinal or lateral A sway brace assembly. It is intended to be combined with a TOLCO transitional attachment, "bracing pipe'and a TOLCO "braced pipe'attachment to form a complete bracing Mounting Hardware assembly. NFPA 13 and/or OSHPD guidelines should be c Is Not Included followed. To Install: Attach the Fig. 906 to the structural surface as per fastener design guidelines.Attach other TOLCO ^ transitional attachment fitting Fig. 909, 910, 980 or 986. Transitional fitting attachment can pivot for adjustment to proper brace angle. Finish: Plain. Contact customer service for alternative ' ..;n x , finishes and materials. � Order By: Figure number and specify dimensions H1 and r�J H2 „�JF 6.t ) i''L Part q B C H1 H2 Approx.wt./100 Number in. (mm) in. (mm) in. (mml in. (mm) 906 12" (305.0) 9" (228.6) 2" Lbs, (kg) (50.81 1/4" 16.3) Specify Specify Load Note:Actual design load determined by anchor and concrete strength, not to exceed the UL Listed maximum(139.3) horizontal load of 2015 lbs. (8.9601). Eaton's B-Line series seismic bracing components are designed to be compatible only with other 8-Line series bracing components, resulting in a listed seismic bracing assembly. Eaton 6-Line Division warranty for seismic bracing components will be the warranty provided in Eaton B-Line Division standard terms and conditions of sale made available by Eaton, except that, in addition to the other exclusions from Eaton 6-Line Division warranty, Eaton makes no warranty relating to 8-Line series seismic bracing components that are combined with products not provided by Eaton. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimoters unless otherwise specified. Eaton - ................... 181 B-Line series Pipe Hangers&Supports 41 Seismic Bracing TOLCOr" Fig. 909 - No-Thread Swivel Sway Brace Attachment Component of State of California OSHPD Approved Size Range: 1"(25mm)bracing pipe. For brace pipe Sizes lacer than Seismic. Restraints System 1"125mm), use Fig, 980. Available with holes for tit"-13 thru 3/4"-10 fastener attachment. Material: Steel, hardened cone point set screw CO U5 Function: The structural component of a sway and seismic bracing system. LISTED Features: This product's design incorporates a concentric attachment opening which is critical to the performance of structural seismic connections. NFPA 13(2010) 9,3.5.8.4 indicates clearly that 4110o#fastener table load values are based only on concentric loading. No `�I� threading of the bracing pipe is required. Open design allows for easy % - g inspection of pipe engagement. %/� ; ... . V, -i0\ P.? FigP1t0011oFigN4t(A) 0 9F g�4L pipe used Clampnand jo ned with together witOhObracing ) *I' ‘) D pipe. Sway brace assemblies are intended to be installed in accordance with 2 NFPA 13 (or TOLCO State of California OSHPD Approved Seismic Restraint m' Manual)and the manufacturer's installation instructions. The required type,number and size of fasteners used for the structure attachment fitting shall Set Screw A be in accordance with NFPA 13 and/or OSHPD. Included B rovals: Undewriters andAppCanada (cUL)r Included in our Seism ciRestra Restraints oratories Lised in theUCatalogSA(UL) Mounting Hardware approved by the State of California Office of Statewide Health Is Not Included Planning and Development(OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Installation Instructions: Fig. 909 is the structural or transitional attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with the"bracing pipe" "T # and TOLCO "braced pipe'attachment, Fig. 1000, 1001, 4A, 4B or 4L to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install: Place the Fig. 909 onto the bracing pipe. Tighten the set screw until the head bottoms out on surface. Attachment can pivot for adjustment to proper brace angle. Finish: Plain. Contact customer service for alternative finishes and materials. Order By: Figure number, fastener attachment size and finish. Part Mounting Hole Brace Number D Pipe Size A Max.Design Approx. B Load Wt./100 in. (met) in. (mm) in. (mml in. (min) lbs. (kN) lbs. (kg) 909-1/2* War (13.5) 1" 1251 6" (152.41 15/ 8" (41.31 2015 (8.96) 91 5 14t.31 909-/8 11/16" (17.5) 1" (25) 6" (152.4) 15/a" (41.31 2015 (8.96) 90 (40.8) 909-3/4 13/16" (20.61 1" (25) 6" (152.4) 15/8" 141.3) 2015 (8.961 69 (40.4) " Standard size. Important! - For load information when using Fig. 909 with pre-installed or post-installed concrete anchors in compliance with NFPA 13 (2016) or ASCE 7-10, including prying factors,see load tables on pages AL1 thru AL21. Eaton's B-Line series seismic bracing components are designed to be compatible only with other 8-Line series bracing components, resulting in a listed seismic bracing assembly. Eaton B-Line Division warranty for seismic bracing components will be the warranty provided in Eaton 13-Line Division standard terms and conditions of sale made available by Eaton, except that, in addition to the other exclusions from Eaton 8-Line Division warranty, Eaton makes no warranty relating to B-Line series seismic bracing components that are combined with products not provided by Eaton. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 183 13-Line series Pipe Hangers&Supports Seismic Bracing TOLCOTM Fig. 980 - Universal Swivel Sway Brace Attachment - 3/s"-16 to 3/4"-10 rods TOLCO""Fig. 980H - Universal Swivel Sway Brace Attachment - 7/8"-9 to 11/C-7 rods Size Range: One Size fits bracing pipe 1'125mm)thru 2"150mm1, 12 gaugechannel, uctural Steel up to /4 (31.7mm California OSHPD 2.6mm) and all strate of 9 , I thick.9 11 Approved Seismic Restraints System Material: Steel. Stainless Steel Type 316 (SS6)optional. Function: Multi-functional attachment to structure or braced pipe fitting. .x C UL U5 Features: This product's design incorporates a concentric attachmentnto Set Screw LISTED •••°�^ opening which is critical to the performance of structural seismic connections. y� �� Included NFPA 13(2010)9.3.5.8.4 indicates clearly that fastener table load values are Mounting Hardware based only on concentric loading. Mounts to any surface angle. Break off bolt Is Not Included head assures verification of proper installation. 0 Installation: Fig.980 is the structural or transitional attachment component A41/4,..... , O of a longitudinal or lateral sway brace assembly. It is intended to be combinedp with the"bracing pipe"and TOLCO 'braced pipe"attachment, Fig, 1000, 1001, B ro ` 2002,4L,4A or 46 to form a complete bracing assembly. NFPA 13 and/or m OSHPD guidelines should be followed. To Install: Place the Fig. 980 onto the "bracing pipe". Tighten the set screw until the head breaks off. Attachment can pivot for adjustment to proper brace ^�-, angle. Approvals:-Underwriters Laboratories Listed in the USA(UL)and Canada (cUL).Approved by Factory Mutual Engineering(FM). Included in our , �� I Seismic Restraints Catalog approved by the State of California Office of 980H I D Statewide Health Planning and Development(OSHPD). For additional load, / spacing and placement information relating to OSHPD projects, please refer c����� { ��to the TOLCO Seismic Restraint Systems Guidelines. \ Note: Fig. 980 Swivel Attachment and Fig. 1001, Fig. 1000, Fig. 2002, \�0/ A \r 8 up a sway brace system of UL ke List d attagchm4e ntsorFig.and bra ng4L pipeclamps materia sawhi h satisfies the requirements of r Underwriters Laboratories and the National Fire Protection Association INFPA) Finish: Plain, Electro-Galvanized or Stainless Steel. Contact customer service 7 for alternative finishes. � Order By: Figure number and finish. US Patent Numbers Pat.#6,273,372,Pat.#6,517,030,Pat.#6,953,174, Pat.#6,708,930,Pat.#7,191,987,Pat.#7,441,730,Pat.#7,669,806 , J. Pan 4. Number A , Max Horizontal Max.Horizontal Design Load"(FM) i B D* Design Load cUL o ° . Approx. in. (mm) in. (mm) in. (mm) i Olbs./(kN) as) bsJ(kN) bsl(kN) bs./(kN) bsJ(kN) lbs. 980-3/a 51/4" (133.3) 17/8" 147.6) 13/32" (10.3► 980-1/2 51/4" (133.31 17/8" (47.6) 17/32" (13.5) ! 149 (67.6) 980-6/8 51/4" (133,3) 17/8" (47.6) 11/16" (17.5) 1 r 148 (67.11 i 147 (66.7) 980-3/4 51/4" 1133.3) 17/8" (47.6) 13/16" (20.5) 980H-7/8 63/4" (171.4) 31/2" (88.9) t5/is" (23.8) 2015 1320 1970 2310 2550 ; 146 166.2) 980H-1 63/4" (171.4) 31/2" (88.9) 11/16" (27.0) (8.96) 15.87) Ie 7fil (10.27) 111.341 402 (182.3) 980H-11/8 63/4" (171.4) 31/z" (88.9) 13/16" (30.2) 400 (181.4) 980H-11/4 63/4" (171.41 31/2" (88.9) 15/Is" (33.3) ' 391 (180.1) " Mounting attachment hole size. 390 (176.9) "` Installed with 1" or 11/4" Schedule 40 brace pipe. Important! -For load information when using Fig. 980 with pre-installed or post-installed concrete anchors in compliance with NFPA 13(2016)or ASCE 7-10,including prying factors,see load tables on pages AL7 thru AL21. Eaton's B-Line series seismic bracing components are designed to be compatible only with other B-Line series bracing components, resulting in a listed seismic bracing assembly. Eaton B-Line Division warranty for seismic bracing components will be the warranty provided in Eaton B-Line Division standard terms and conditions of sale made available by Eaton. except that, in addition to the other exclusions from Eaton B-Line Division warranty, Eaton makes no warranty relating to B-Line series seismic bracing components that are combined with products not provided by Eaton. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Pipe Hangers&Supports _ 186 Eaton Seismic Bracing TOLCO'Fig. 1000- "Fast Clamp" Sway Brace Attachment Component of State of a Size Range: Pipe size to be braced: 1"(25mm)thru 6-(150mm)Schedule 10 Seism cRestraintsOSHPD System thru 40 IPS. Pipe size used for bracing: 1'125mm)and 11/4"132mm)Schedule 40 IPS. Material: Steel cCL US Function: A restraint device intended for lateral bracing. LISTED °°Vr° Features: Field adjustable, making critical pre-engineering of bracing pipe unnecessary. Hardware Unique design requires no threading of bracing pipe. Can be used as a component of a Included 4-way riser brace.Can be used as longitudinal brace with Fig. 907. Steel leaf spring insert provided to assure installer and inspector necessary minimum torque has been achieved. I Installation: Fig. 1000 is the"braced pipe"attachment component of a lateral sway brace assembly. It is intended to be combined with the 'bracing pipe'and TOLCO j '' \\;) structural attachment component, Fig. 980, 910 or 909 to form a complete bracing � � assembly. Follow NFPA 13 and/or OSHPD guidelines. /� ) rn _ c To Install: Place the Fig. 1000 over the pipe to be braced, insert bracing pipe through e opening leaving a minimum of 1"extension. Brace pipe can be installed on top or bottom / • CO of pipe to be braced. Tighten hex nuts until leaf spring is flat. It is recommended that the `• ni brace angle be adjusted before hex nuts are fully tightened. _ Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL).Approved g y for use with Allied Dyna Flow sprinkler pipe upto 2'as a restraint device. Maximum UL Listed Desi n Load horizontal design load is 655 lbs. 12.91kN)Torque requirement is 6-8 ft./lbs. (8-lONm) 1 (z5mm1 thru 2"(59mn,I pipe size-655 Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints Catalog lbs.(291kNJ approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Application Note: Position Fast Clamp and tighten two hex nuts until leaf spring flattens. A minimum of 1'pipe extension beyond the Fig. 1000 is recommended. Finish: Plain. Contact customer service for alternative finishes and materials, Order By: Order first by pipe size to be braced, followed by pipeI* size used for bracing, figure number and finish. Lateral Brace Pipe i Part Number&Approx.WtJ100 Size 1"124mm)Brace Pipet Max.Horizontal Design Load(FM)42 in. (nun) ? 1/4"(32mm)Brace Pipe 30°-44° 45°-59° 60°-74° 756-90° Lbs. (kg) lbs. (kg) Lbs. (kN) Lbs. (k61) Lbs. (kN) lbs. (kN) 1" (251 , 1000-1 X 1 71.6 (32.5) i 1000-1 X 11/4 75.8 (34.41 ( 200 (0.89) 280 (1.24) 340 (1.51) 380 1114" (32) j 1000-11/4 X 1 74.8 (33.9) 1000-11/4 X 11/4 79.1 (35.9) 200 (0.89) 280 (1.24) 340 (1.51) 380 (1.69) 11/2" (40) 1000-11/2 X 1 77.8 (35.3) ; 1000-11/2 X 11/4 82.1 (37.2) j 200 (0.89) 280 (1.241 340 (1.51) 380 (1.69) 2" (50) i 1000.2 X 1 84,1 (38.1) 1000-2 X 11/4 88.4 (40.1) 200 10.89) 280 (1.24) 340 (1.51) 380 (1.69) 21/2" (65) j 1000-21/2 X 1 90.2 (40.9) j 1000-21/2 X 11/4 94.6 (42.9) i 200 (0.89) 280 (1.24) 340 (1.51) 380 (1.69) 3" (80) 11000-3 X1 97.3 144.1) 1000-3 X 11/4 101.7 (46.1) 230 (1.02) 320 (1.42) 400 (1.78) 450 (2.00) 31/2" (90) ? 1000-31/2 X 1 104.0 (47.2) i t11/4 0003hX 108.4 4 4" 1101 1000.4 X 1 110.3 (50.0 1000-4 X 11/4 114.6 152.0) 230 (1.02) 320 (1.42) 400 (1.78) 450 (2.001 5" 1125) 1000-5 X 1 123.1 (55.8) 1000-5 X 11/4 127.4 (57.8) I -- -- -- -- 6" (150) ; 1000-6 X 1 136.5 (61.9) 1000-6 X 11/4 140.8 (63.8) -- 1 FM Approved when used with 1, 11/4, 11/2,or 2 inch NPS Schedule 40 GB/r 3091,EN 10255H,or JIS G3451 steel pipe as the brace member. 2 Load rating for LW above refers to FM Approved Lightwall Pipe commonly referred to as"Schedule 7".These ratings may also be applied when EN 10220 and GB/r 8163 steel pipe. 3 Load rating for Schedule 10 above may be applied to GB/r 3092.EN 10255M and H,or JIS G3454,FM Approved Thinwall,or Schedule 40 steel pipes. Note:See UL load ratings in UL Listed Design Load chart shown under drawing. Eaton's B-Line series seismic bracing components are designed to be compatible only with other B-Line series bracing components, resulting in a listed seismic bracing assembly. Eaton B-Line Division warranty for seismic bracing components will be the warranty provided in Eaton B-Line Division standard terms and conditions of sale made available by Eaton, except that, in addition to the other exclusions from Eaton B-Line Division warranty, Eaton makes no warranty relating to B-Line series seismic bracing components that are combined with products not provided by Eaton. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. 9-Line series Pipe Hangers&Supports 192 Eaton Seismic Bracing TOLCO'" Fig. 1001 - Sway Brace Attachment Component of State of California OSHPD Approved Size Range: Pipe Size to be braced: 1'(25mm) thru 8'(200mm) IPS. Seismic Restraints System ° Pipe size used for bracing: 1'(25mm)and 11/a'(32mm) Schedule 40 IPS. nilibin Material: Steel c 0 Us Function: For bracing pipe against sway and seismic disturbance. LISTED The pipe attachment component of a sway brace system: Fig. 1001 is used in conjunction with a Fig. 900 Series fitting and joined together with bracing pipe per NFPA 13, forming a complete sway brace assembly. Features: Can be used to brace schedules 7 through 40 IPS. Field adjustable, / making critical pre-engineering of bracing pipe length unnecessary, Unique design ? requires no threading of bracing pipe. Can be used as a component of a four-way (;I y co riser brace. Comes assembled and ready for installation. Fig. 1001 has built-in E. visual verification of correct installation. See installation note below. 3 4y" Installation Note: Position Fig. 1001 over the pipe to be braced and tighten r Set Screws C i Included d two hex head cone point set screws until heads bottom out. A minimum of 0. U 1'125mm)pipe extension is recommended. Brace pipe can be installed on top or bottom of pipe to be braced. Pipe Max.Horizontal Design Load(UL)-Lbs. Approvals: Underwriters Laboratories Listed in the USA and Canada(cULus). Size For Brace Pipe Size 1"/11/4" Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints Sc1 / "/1 10 "/11/4 Catalog approved by the State of California Office of Statewide Health Planning i, Imml 1"/11/4" 1"/11/a" 1"/11/a" and Development(OSHPD). For additional load, spacing and placement 1" (25) /-- 1000/1000 1000/1000 information relating to OSHPD projects, please refer to the TOLCO Seismic 11/4" (32) 1000/1000 1000/1000 1000/1000 Restraint Systems Guidelines, OPA-0300-10. Finish: Plain or Electro-Galvanized. Contact customer service for alternative 11/2 (40) 1000/1000 1500/1500 1500/1500 finishes and materials. 2" 150) 1000/1000 2015/2015 2015/2015 Order By: Indicate pipe size to be braced followed by pipe size used for bracing, 21/2" (65) 1600/1600 2015/2765 2015/2765 figure number and finish. 3" (80) 1600/1600 2015/2765 2015/2765 Important Note: Fig. 1001 is precision manufactured to perform its function as 4" (100) 1600/1600 2015/2765 1015/2765 a critical component of a complete bracing assembly. To ensure performance, the 6" (150) 1600/1600 2015/2765 2015/2765 UL Listing requires that Fig. 1001 must be used only with other TOLCO bracing products. 8" 1200) 1600/1600 2015/2765 2015/2765 Part Number&Approx.WOW • Pipe Max.Horizontal Design Load(FM) Size 1"(z4mm)Brace Pie i11/4" ° For Sch.?,Sch.10,&Sch.40 Pipe t.zr in. 1mm) p (32mm)Brace Pipe 30°-44 45°-59° 60°-74° 75°-90° kN) Lbs. (kN) 1" (251 1001-1 X 1 100.0 (45.31 1001.1 X 11/4 118.0 (53.5) ! 1800 (8.00) 1 2550 (11.34) 3120(13.88) 3490 (25.52) 11/4" (32) 1001-11/4 X 1 100.0 (45.3) 1001-11/4 X 11/4 114.0 (51,7) 1230 (5.47) 1740 17.74) 2140 (9.52) 2380 (10.58) 11/2" (40) 1001-11/2 X 1 100.0 (45.3) j 1001.11/2 X 11/4 115.0 (52.11 ; 1230 (5.41) 1740 (7.74) 2140 (9.52) 2380 (10.58) 2" 150) 101-2 X 1 108.0 (49.01 1001-2 X 11/4 121.0 (54.9) 1230 (5.47) 1740 (7.74) 2140 (9.52) 2380 (10.58) 21/2" (65) 1001-21/2 X 1 138.6 (62.8) 1001-21/2 X 11/4 160.4 (72.7) i 800 (3.56) 1130 (5.02) 1380 (6.14) 1540 (6.85) 3" (80) 1001-3 X 1 147.2 (66.7) 1001-3 X 11/4 168.7 (76,51 ; 850 (3.78) 1200 (5.34) 1470 (6.54) 1640 (7.29) 4" (100) 1001-4 X 1 160.9 173.0) 1001-4 X 11/4 182.4 (82.7) 850 (3.78) 1200 (5.34) 1470 (6.54) 1640 (7.291 6" (150) 1001-6 X 1 190.0 (86.2) 1001-6 X 11/4 211.4 (95.9) 510 (2.27) 730 (3.251 890 (3.96) 990 (4.40) 8" (200) 1001-8 X 1 217.4 (98.61 1001-8 X 11l4 238.8 (108.3) j 510 12.27) 730 13.25) 890 (3.96) 990 (4.40) 1 FM Approved when used with 1 or 11/4 inch NPS Schedule 40 GB/T 3091,EN 10255H,or JIS G3451 steel pipe as the brace member. 2 Load rating for LW above refers to FM Approved Lightwall Pipe commonly referred to as "Schedule 7".These ratings may also be applied when EN 10220 and GB/T 8163 steel pipe. 3 Load rating for Schedule 10 above may be applied to GB/T 3092,EN 10255M and H,or JIS G3454, FM Approved Thinwall, or Schedule 40 steel pipes. Note: See UL load ratings in UL Listed Design Load chart shown under drawing. all II All dimensions in charts and on drawings are in inches.Dimensions shown in Eaton -- - --- -- -- ___ parentheses are in millimeters unless otherwise specified. 193 B-Line series Pipe Hangers&Supports FI11L'T1 Product information High-performance intumescent firestop ar; sealant FS-ONE MAX Applications ■ For effectively sealing most common through penetrations in a variety of base materials , IN For use on concrete,masonry and drywall00 n ■ Mixed and multiple penetrations • Metal pipe penetrations:copper,steel and EMT / ■ Insulated metal pipe penetrations:steel and copper 4,` +r' I • Plastic pipe penetrations:closed or vented " " ' Advantages :I 1 T compliant ;- • US-produced:"Buy American" tt i• One product for a variety of common through penetrations ��" a 1- IN Cost-effective,easy-to-use solution • Water-based and paintable Technical data ■ Industry-leading VOC results Chemical basis Water-based acrylic dispersion ■ Ethylene glycol-free Approx.Density 84.3 Ib/ks Color Red FBGApplication temperature range 41-104°F Viral EOxrpmlr Approx.cure time', 4 mm/3 days rated ed Temperature resistance range -4 to 212°F Chemical Mold and mildew Mold and mildew performance Class 0(ASTM G21-96) resistant resistant Mold and mildew resistance Yes 'ys,y FILL.VOID OR CAVITY MATERIAL Surface burning characteristics Flame spread:0 u o FOR USE IN THROUGH-PENETRATION UL 723(ASTM E84 FIRES OP SYSTEMS ) Smoke development:10 US pPPaovm ° OS SEE UL FIRE RESISTANCE DIRECTORY Tested in accordance with UL 1479,ASTM E814,ASTM E84, CAN/ULC-5115,ASTM G21,ASTM E90 Intertek California State fire marshal approval CSFM Listing 4485-1200:0108 for FS-ONE MAX Intumescent Firestop Sealant Expansion ratio(unrestricted,up to) 1:5 n at 75°F/24°C,50%relative humidity 11.1111611r1v.. gkjl Osota E3.MAX.. .4-:,-,..:,.. x: _ ........, _ Order Designation Package Content Item number FS-ONE MAX 20oz foil(3 case+disp) 1x Foil pack dispenser manual CS 270-Pt 75x Firestop sealant FS-ONE MAX 20 oz foil 3530252 FS-ONE MAX 10oz tube(1 case) 12x Firestop sealant FS-ONE MAX 10 oz cartridge 3530249 FS-ONE MAX 5 gallon(18 pails) 18x Firestop sealant FS-ONE MAX 5 gallon pail 3530263 FS-ONE MAX 20oz foil(1 case) 25x Firestop sealant FS-ONE MAX 20 oz foil 3530250 FS-ONE MAX 20oz foil(3 cases) 75x Firestop sealant FS-ONE MAX 20 oz foil 3530251 FS-ONE MAX 20oz Foil-Pallet 600x FSONE-MAX 20 oz foil,290x Bulk Shipping Condition 3534713 FS-ONE MAX 10 oz cartridge 2101531 FS-ONE MAX 5 gallon pail 2101533 Hilt. Outperform. Outlast. © © is El Hirai,Inc.(USA)1-800-879-80001 www.us.hilti.com I en espanol 1-800-879-5000 I Hilti(Canada)Corp.1-800-363-4458 I www.hilti.ca Bunetin 205 January 2022 Reliable Sprinkler Wrenches Standard Wrenches Model 0856 Wrench Model JD Wrench aF e�„, • D556 • D-1.0-3,0.4,0-5 guards on K5.6 ,_:. M,a,•,p 'tv r,"; 4 y---- ,. (80)and smaller sprinklers Model FM Wrench Model JV Wrench _ - -_ F30R • D-6.D-7,0-8,D-9 guards on spnnkters _ F3Res • DH Dry Model H Wrench Modal W2 Wrench • GL112 AH • GXLO •• FIRes • KFR • GVELO DD • F1S • LT56, • GFR VELD / DH,except Dry ' G LT56L • MBEC -..._. • F1 • GFR • KRes • F1FR • GP • WP56 Model J1 Wrench • WPS6L • J Model W5 Wrench"^a h.,�y _ c ,.. ' • JL • HL-22 :.`. • N25 '�- N252EG TNL280 Model J Wrench ` • D-1,0-3,0-4,0-5 guards on K8.0 ,4 •r '-i (115)sprinklers • F series guards on sprinklers Recessed/Concealed Wrenches Model FC Wrench Model RJ Wrench Model XL02 Wrench • G5-56 Dry • J • F3 • G5 without cap •JL F30R • RFC without cap •w{ F3Rec • LT56C without cap - r•• WP56C ,.u,_- q#:"' • DH Dry • GFR VELD Model G4 Wrench Model W1 Wrench Model ZX Wrench 4,..r-m, • F4FR • :Res R • • G4 • es XL Pendent — '5- • G4XLO u � 1r �� Model G6 Wrench Model W3 Wrench Model ZX-HSW Wrench G6 • G5wilh wrenchabkwp a'�-,..%°'. - XLHSW i. • RFS • RFC widr wrench-able cap • LT56C wieth wrench-able cap r ,..^t`r, .I Model N Wrench Model W4 Wrench • N252EC0 • F1Res • F1S • F1,FILL, • LT56. F1SS LT56L • F1FR. • GFR FIFRLL, • KFR F1FRSS • KRes Model RC1 Wrench Model W6 Wrench w•_ • G Recessed plastic Iknited wrench 4. ii'. for spare spmkler-use cabinet -RFC without cap c 3 18 1 0 0 0 mew.reliablesprinNer.coin PFE Sprinkler Gauge Description & Features: • Specially designed for fire sprinkler systems :_ • Suitable for air and water media 150 5 • Corrosion resistant case m \ • Dual scales(psi/kpa, psi/bar, psi/kg/cm')and &�0 ++7CQ i2f single scale(psi)pressure ratings „� i ) �, t • Approved by Factory Mutual (FM)and listed by A e 6,,„, PFE SERI Underwriter LaboratoryUL-393 , USA and Canada ha Ai, Internal pointer over-travel stop aflo tti • ASME B40.100 compliant 20f Z gekso A CRN registered `'' �` _ ., 5 year warranty +NrV:$ aet ✓% .' Applications: 4` "` • Ideally suited for fire sprinkler systems and fire fighting " —_ equipment • Suitable for non-clogging and non-corrosive media C UL US APPRRVFf Specifications il Dial 3.5"(90mm),white aluminum with black and red markings Case Black plastic Lens Polycarbonate, threaded Socket Brass Connection 1/4" NPT standard, bottom Bourdon Tube Phosphor bronze Movement Brass Pointer Aluminum, black Welding Silver Alloy Working Pressure Maximum 75%of full scale value Ambient(Process -40°F to 150°F (-40°C to 65°C Temperature 65°C) Accuracy ±3-2-3%ASME Grade B Enclosure Rating IP52 A WARNING:This product can expose you to chemicals including lead,which is Warning I known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov. Order Codes (products in bold are normally stock in North America) .+:.Y2° Product Air Water Air s 0/80/retard/250 psi PFE3932R1 v--- -_„ 0/300 psi - PFE3933R1 ao 50 '0/801retard/250_psi/kPa PFE3932 - �T� ' 6"0 `; 0/300 ss/kPa PFE3933 PFE3935 soo 400 ` 0l80/retard/250 isilbar PFE3932R1R11111111111111111111 r N ' 28C1PFESEWS a 1 0/300psi/bar PFE3933R1R11 :z: c"�" "' t • r too • o' 4P4 o I C?) l ni 1 um . , ��a 2(C.i59'j II :NP 112 Tel: 1-800-WINTERS/www.winters.com WINTERS INSTRUMENTS