Loading...
Permit 1- zc5z2- ccx�3 PATRIOT 4708 NE MINNEHAHA ST VANCOUVER,WA 98661 FIRE PROTECTION INC. TEL(360)699-4403 FAX(360)699-4485 RECEIVED Fire Protection 01 261 . y� CITY OF TIG,ARD Seismic Calculation BUILDING OIVISin- Submittal for Tigard Senior Housing Tigard , OR 8815 SW Omara Street Tigard, OR 97223 ATRIOT Job #31 -1544 P6 TACOMA,WA OFFICE www.patriotfire.com SPOKANE,WA OFFICE TEL(253)926-2290 PATRIFP099CF/CCB#70822 TEL(509)926-3428 FAX(253)922-6150 FAX(509)926-3708 TOLBraceTM Seismic Bracing Calculations Contractor: Patriot Fire Protection, Inc. Project Address: Tigard Senior Housing Address: 4708 NE Minnehaha St Vancouver,WA 98661T. 1 et 8815 SW Omara Street phone: 360.699.4403 Fimor;orgiksinesslbbrur%'Ida Tigard. OR 97223 Licence: PATRIFP099CF Job#31-1544 Calculations based on 201e NFPA Pamphlet#13 Brace Information TOLCOTM Brace Components Maximum Brace Length T O'(2.134 m) TOLCOTM Component Listed Load Adjusted Load Diameter of Brace 1' Fig. 1001 Clamp 1200 lbs(544 kg) 1200 lbs(544 kg) Fig.980 Universal Swivel 1970 lbs(894 kg) 1970 lbs(894 kg) Type of Brace Sch.40 See Fastener Information "Calculation Based on CONCENTRIC Loading Angle of Brace 45° Min. "Please Note:These calculations are for TOLCOT"components only.Use of any other components voids these calculations and the listing of the assembly. Least Rad.of Gyration 0.42" (11 mm) Seismic Brace Assembly Detail UR Value 200 Max Horizontal Load 1310 lbs(594 kg) TOLCO FIG. 980 Other Requirements - FM Approved Loads UNIVERSAL SWAY BRACE ATTACHMENT Fastener Information STEEL PIPE .; Orientation to Connecting Surface NFPA Type B Fastener �z f, ..4s'`' , f.y.r.., Type Lag-Screw J f�.•Diameter 1in. (13mm) 1 „ <41m.. .1 , Length TOLCO FIG. 1001-/ f h q 31n_(76 mm) FAST CLAMP �• ¢Ili 7a,1 �.,(4. Maximum Load 4 * J• Gt_S 252 Ibs (114 kg) ___ ___ _ _- ...___ ii.xrit tE:S Ittarbi Brace Identification on Plans 4"Lateral#1 Prying Factor N/A Brace Type Lateral[X] Longitudinal[ ] 4-Way( I Sprinkler System Load Calculation (Fpw= CpWp) Cp= 0.4028 Diameter Type Length Total Length Weight Per Unit Length Total Weight 4"(100 mm) Sch. 10 30 ft(9.1 m) 30 ft(9.1 m) 11.78 lb/ft(17.53 kg/m) 353 lbs(160 kg) Subtotal Weight 353 lbs(160 kg) Wp(incl. 15%) 406 lbs(184 kg) Main Size Type/Sch. Spacing(ft) I Total(Fpw) 164 lbs(74 kg) 4" Sch.10 30 Maximum Fpw per 9.3.5.5.2(if applicable) 1071 lb(485 kg) lTOLBraceT"Version 81 Use of TOLBraceT"is subject to terms and conditions per the end user license agreement TOLBraceTM Seismic Calculation Tigard Senior Housing Job#31-1544 8815 SW Omara Street Puwetkr,9 fius9iess 4Ynrldurde Brace Identification 4' Lateral#1 Brace Type(Per NFPA#13) NFPA Type B Braced Pipe (ft) 4"Sch.10 Steel Pipe Spacing of Brace 30'0" (9.14 m) Orientation of Brace Lateral Bracing Material 1"Sch.40 Maximum Brace Length 7'0"(2.13 m) Slenderness Ratio used for Load Calculation 200 True Angle of Brace for Calculation 45° Type of Fastener 1/2 x 3(13 x 76 mm) Lag-Screw Length of Fastener 3in. (76 mm) Summary of Pipe within Zone of Influence 4"Sch.10 Steel Pipe(101.6 mm) 30 ft(9.1 m) G-Factor Used 0.4028 Allowance for Heads and Fittings 15% Conclusions Total Adjusted Load of Pipe in Zone of Influence 164 lbs (74 kg) Material Capacity 1310 lbs(594 kg) Fastener Capacity 252 lbs(114 kg) Fig. 1001 Clamp 1200 lbs(544 kg) Fig.980 Universal Swivel 1970 lbs(894 kg) Structural Member Wood Decking Calculations prepared by Kevin Long The description of the Structural Member is for informational purposes only. TOLBraceTM software calculates the brace assembly only,not the structure it is attached to. Calculated with TOLBrace^'8 visa us at www.tolco.com TOLBraceTM Seismic Bracing Calculations Contractor: Patriot Fire Protection,Inc. Project Address: Tigard Senior Housing_ _ Address: 4708 NE Minnehaha St Vancouver,WA 98661 Ax 8815 SW Omara Street Phone: 360.699.4403 Pawer;eg&a Hass WorAwide Tigard. OR 97223 Licence: PATRIFP099CF Job#31-1544 Calculations based on 2016 NFPA Pamphlet#13 Brace Information TOLCOTM Brace Components Maximum Brace Length 7'0"(2.134 m) TOLCOT" Component Listed Load Adjusted Load Diameter of Brace 1" Fig.4LA Clamp 970 lbs(440 kg) 970 lbs(440 kg) Fig.980 Universal Swivel 1970 lbs(894 kg) 1970 lbs(894 kg) Type of Brace Sch.40 See Fastener Information Angle of Brace 45° Min. 'Calculation Based on CONCENTRIC Loading 'Please Note:These calculations are for TOLCO""components only.Use of any other components voids these calculations and the listing of the assembly. Least Rad.of Gyration 0.42° (11 mm) Seismic Brace Assembly Detail LJR Value 200 Max Horizontal Load 1310 lbs(594 kg) „'&17`,°mI4 t er equirements -FM Approved Loads .„a. . ..„. Fastener Information ° Orientation to Connecting Surface NFPA Type B - - .YxCI r04W fq xU - twrsO\ {I I a�i..f'� Fastener °.+ciin.<„uirn �:,. Nsii Type La Screw ® , �'�6., fir,. ii g } T1E — 13. 461'E T _ Diameter 1/2in. (13 mm) / t �� ar, � ].. 0 . i" GO' Length 3in. (76 mm) U ..,. i_L_/ 't` 1e,14�� •_ - - - -� n.an rox„ L. Maximum Load - - - -- „11 At.. „-.Y- J- GL J� lbs kg)- _ ___ .. _. . _.. i•xPIr.ES Brace Identification on Plans 4"Longitudinal#1 Prying Factor N/A Brace Type Lateral[ ] Longitudinal[X] 4-Way[ ] Sprinkler System Load Calculation (Fpw= CpWp) Cp= . 0.4028 Diameter Type Length Total Length Weight Per Unit Length Total Weight 4"(100 mm) Sch. 10 30 ft(9.1 m) 30 ft(9.1 m) 11.78 lb/ft(17.53 kg/m) 353 lbs(160 kg) Subtotal Weight 353 lbs(160 kg) Wp(inch 15%) 406 lbs(184 kg) Main Size Type/Sch. Spacing (ft) I Total(Fpw) 164 lbs(74 kg) <" scn.10 ao Maximum Fpw per 9.3.5.5.2(if applicable) N/A 1TOLBracel'A Version 81 Use of TOLBrace a is subject to terms and conditions per the end user license agreement TOLBraceTM Seismic Calculation Tigard Senior Housing Job#31-1544 8815 SW Omara Street T. Pawn g Easiness 4tiwMu(de Brace Identification 4"Longitudinal#1 Brace Type(Per NFPA#13) NFPAType B Braced Pipe(ft) 4"Sch.10 Steel Pipe Spacing of Brace 30'0"(9.14 m) Orientation of Brace Longitudinal Bracing Material 1"Sch.40 Maximum Brace Length 7'0"(2.13 m) Slenderness Ratio used for Load Calculation 200 True Angle of Brace for Calculation 45° Type of Fastener 1/2 x 3(13 x 76 mm) Lag-Screw Length of Fastener 3in. (76 mm) Summary of Pipe within Zone of Influence 4"Sch.10 Steel Pipe(101.6 mm) 30 ft(9.1 m) G-Factor Used 0.4028 Allowance for Heads and Fittings 15% Conclusions Total Adjusted Load of Pipe in Zone of Influence 164 lbs(74 kg) Material Capacity 1310 lbs(594 kg) Fastener Capacity 252 lbs (114 kg) Fig.4LA Clamp 970 lbs (440 kg) Fig.980 Universal Swivel 1970 lbs(894 kg) Structural Member Wood Decking Calculations prepared by Kevin Long 'The description of the Structural Member is for informational purposes only. TOLBracer"software calculates the brace assembly only,not the structure it is attached to. Calculated with TOLBrace`e"8 Visit us at www.lolco.com TOLBraceTM Seismic Bracing Calculations Contractor: Patriot Fire Protection,Inc. Project Address: Tigard Senior Housing Address: 4708 NE Minnehaha St Vancouver,WA 98661 as 8815 SW Omara Street flnverw 6oxiness Worki>vrifo Phone: 360.699.4403 Tigard. OR 97223 Licence: PATRIFP099CF Job#31-1544 Calculations based on 2016 NFPA Pamphlet#13 Brace Information TOLCOTM Brace Components Maximum Brace Length 7'0"(2.134 m) TOLCOTM Component Listed Load Adjusted Load Diameter of Brace 1" Fig. 1001 Clamp 1200 lbs(544 kg) 1200 lbs(544 kg) Fig.980 Universal Swivel 1970 lbs(894 kg) 1970 lbs(894 kg) Type of Brace Sch.40 YP -__ See Fastener Information 45° Min. *Calculation Based on CONCENTRIC Loading Angle of Brace *Please Note:These calculations are for TOLCOT4'components only.Use of any other components voids these calculations and the listing of the assembly. Least Rad.of Gyration 0.42" (11 mm) Seismic Brace Assembly Detail L/R Value 200 Max Horizontal Load 1310 lbs (594 kg) Other Requirements - FM Approved Loads • -T' Y .� � Fastener Information ,- (j ' \ w"VfnS,LswAY / `-cotlaciL V SPACEAnK10.1EIIT MOOR Orientation to Connecting Surface NFPA Type B �I\ Fastener \ `%;O yfr{:; V:i kA\ ,. 'i 7•, Type Lag-Screw Lu w f3.'RIPE Diameter 1/2in. (13 mm) 'r' "'O'' I . "G UMW t'y "h ta.i4� �a Length 3in. (76 mm) RG J. GE 5 Maximum Load 252 lbs (114 kg) 1.xplr,[-S Brace Identification on Plans 4"4-Way#1 Prying Factor N/A Brace Type Lateral[ ] Longitudinal( ] 4-Way[X] Sprinkler System Load Calculation (Fpw=CpWp) 0.4028 Diameter Type Length Total Length Weight Per Unit Length Total Weight 4"(100 mm) Sch. 10 20 ft(6.1 m) 20 ft(6.1 m) 11.78 lb/ft(17.53 kg/m) 236 lbs(107 kg) Subtotal Weight 236 lbs(107 kg) Wp(incl. 15%) 271 lbs(123 kg) Main Size Type/Sch. Spacing(ft) I Total(Fpw) 109 lbs(50 kg) a" Sch.10 20 Maximum Fpw per 9.3.5.5.2(if applicable) N/A fTOLBraceTM Version 81 Use of TOLBraceT"is subject to terms and conditions per the end user license agreement TOLBraceTM Seismic Calculation Tigard Senior Housing Job#31-1544 8815 SW Omara Street 4are rvacnrrq a seless4Ynrliiv4e Brace Identification 4 4-Way#1 Brace Type(Per NFPA#13) NFPAType B Braced Pipe(ft) 4"Sch.10 Steel Pipe Spacing of Brace 20'0" (6.1 m) Orientation of Brace Riser Bracing Material 1"Sch.40 Maximum Brace Length 7' 0"(2.13 m) Slenderness Ratio used for Load Calculation 200 True Angle of Brace for Calculation 45° • Type of Fastener 1/2 x 3 (13 x 76 mm) Lag-Screw Length of Fastener 3in. (76 mm) Summary of Pipe within Zone of Influence 4"Sch.10 Steel Pipe(101.6 mm) 20 ft(6.1 m) G-Factor Used 0.4028 Allowance for Heads and Fittings 15% Conclusions Total Adjusted Load of Pipe in Zone of Influence 109 lbs (49 kg) Material Capacity 1310 lbs(594 kg) Fastener Capacity 252 lbs(114 kg) Fig. 1001 Clamp 1200 lbs(544 kg) Fig.980 Universal Swivel 1970 lbs(894 kg) Structural Member Wood Stud Calculations prepared by Kevin Long •The description of the Structural Member is for informational purposes only. TOLBraceT"software calculates the brace assembly only,not the structure it is attached to. Calculated with TOLBrace"6 1 Visit us at www.tolco.com