Permit
III4 CITY OF TIGARD BUILDING PERMIT I . '-. COMMUNITY DEVELOPMENT Permit#: BUP2022-00101 Date Issued: 5/31/2022 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S101CA00200 Jurisdiction: Tigard Site address: 13240 SW WALL ST Project: Agilyx R&D Center Subdivision: None Lot: None Project Description: New 3573 sqft TI within existing warehouse.The work includes the construction of a new mezzanine for storage and mechanical use. Contractor: GROW CONSTRUCTION LLC Owner: WALL STREET INDUSTRIAL LLC 7900 SW HUNZIKER ST 13170 SW WALL ST TIGARD, OR 97223 TIGARD, OR 97223 PHONE: 503-597-2425 PHONE: FAX: Specifics: FEES Description Date Amount Type of Use: COM Class of Work: ALT Type of Const: IIIB Permit Fee-Additions,Alterations, 05/31/2022 $4,097.12 Occupancy Grp: S-1 Occupancy Load: 30 Demolition 12/o State Surcharge-Building 05/31/2022 $491.65 Dwelling Units: 0 Plan Review 04/21/2022 $2,663.13 Stories: 0 Height: 0 ft DC Provision Review,COM TI-Ping 05/31/2022 $434.00 Bedrooms: 0 Bathrooms: 0 Plan Review-Fire Life Safety 05/31/2022 $1,638.85 Value: $612,405 Info Process/Archiving-Lg$2.00(over 05/31/2022 $94.00 11x17) Info Process/Archiving-Sm$0.50(up to 05/31/2022 $52.50 Floor Areas: 11x17) Total Area: 0 Metro CET 05/31/2022 $734.89 Accessory Struct: 0 Wash Co Trans Dev Tax 05/31/2022 $17,730.92 Basement: 0 Tigard Trans SDC Improvement 05/31/2022 $13,410.67 Carport: 0 Tigard Trans SDC Reimbursement 05/31/2022 $774.07 Parks SDC Improvement 05/31/2022 $1,761.50 Covered Porch: 0 Parks SDC Reimbursement 05/31/2022 $321.75 Deck: 0 Garage: 0 Mezzanine: 3395 Total $44,205.05 Required: Required Items and Reports(Conditions) 1 Special Inspection(see plans) Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by callirtg 503.232.1 7 or 1.800.332.2344. Issued B \ Permittee Signature: v\ik j t\.., € .7. .639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application f3- I219121 Commercial FOR Of FICF 1'SF 0:11.N' City of Tigard RECEIVED ��2022- g#7 Permit No. 2022-001oI 111 13125 SW Hall Blvd.,Tigard,OR 97223 DEC 0 9 2021 Plan Review Related Permit: ■ Phone: 503-718-2439 Fax: 503-598-1960 Date/By: '�',P13r2,2, l i; P O Inspection Line: 503-639-4175 Date Ready/By: � 51 See Page 2 for • Internet: www.tigard-or.gov CITY OF TIGARD N ed/Method. 11 .. Supplemental Information BUILDING DIVISION i TYPE OF WORK REQUIRED DATA: -AND 2-FAMILY DWELLING — ElNew construction ❑Demolition Permit fees*are based on the value of the work performed. ----- Indicate the value(rounded to the nearest dollar)of all lij Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. 0 1-and 2-family dwelling IXCommercial/industrial Valuation: $ Number of bedrooms: ElAccessory building ❑Multi-family ❑Master builder 0 Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: 13240 SW Wall St. New dwelling area: square feet City/State/ZIP: Tigard, Oregon 97223 Garage/carport area: square feet Suite/bldg./apt.#: Project name: Agilyx Research and Development Center Covered porch area: square feet Cross street/directions to job site: Deck area: square feet At the end of SW Wall street.Closest intersection is SW Hunziker St.and SW Wall St. Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: I Lot#: Permit fees*are based on the value of the work performed. Tax map/parcel#: 2S 101 CA00200 Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. This project consists of a new 3,573 SF research and development center Valuation: $612,405 tenant improvement within an existing warehouse.The new work also includes Existing building area: 45,852 square feet the construction of a new mezzanine for storage and mechanical uses. New building area: No Change square feet ❑ PROPERTY OWNER OD TENANT Number of stories:1 i) Name: AgilyX Type of construction: III-B Address: 12340 SW Wall St. Occupancy groups: S-1, F-1, B-1 +' Oregon 97223 9 Existing: S-1, F-1, B-1 City/State/ZIP: Tigard, Phone:(503)217 3160 Fax:( ) New: S-1, F-1, B-1 riJ APPLICANT © CONTACT PERSON BUILDING PERMIT FEES* SBusiness name:CIDA, INC (Please refer to fee scheduler Rebecca Kerr Structural plan review fee(or deposit): 43 Contact name: FLS plan review fee(if applicable): —' Address: 15895 SW 72nd Ave, Suite 200 City/State/ZIP: Portland, Oregon 97224 Total fees due upon application: Phone:( 503)226-1285 ! Fax: :(503)226-1670 Amount received: / E-mail: rebeccak@cidainc.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* {l► Commercial and residential prescriptive installation of CONTRACTOR roof-top mounted PhotoVoltaic Solar Panel System. Business name: TBD / Submit two(2)sets of roof plan with connection details C9/Z►..f Cott 5a,.l and fire department access,along with the 2010 Oregon Address: 64) 51..-f ytt( /1 Z4 �- r�"'-r Solar Installation Specialtr Code checklist. City/State/ZIP: Art Permit fee(includes plan review $180.00 . i --- and administrative fees): Phone:( ) ,,,,„ Fax:( ) State surcharge(12%of permit fee): $21.60 CCB Lic.: `!r t a Total fee due upon application: $201.60 .kintiorited atgr+ature:. a .-- This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. ' Print name: Rebecca Kerr Date: 12/08/2021 * Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Permits\BUP_COM_PermitApp.doe Rev.04/21/2014 440-46I3T(11/02/COM/WEB) 53 TDT/TSDC Estimate 5/17/2022 BUP2022-00101/13240 SW Wall St AML TDT&RESIDENTIAL TSDC RATES EFFECTIVE 7/1/21 NON-RES:TSDC CITYWIDE EFFECTIVE 7/1/21 0 Yes Project is in River Terrace ? Di No * For TDT and residential formula has been replaced with published rate per unit. Former Use ITE Rate per Rate per TDT/TSDC Rate Type Use# Code PHVT PHVT Unit* # Units Amount Description TDT 1 150 $4,822 30.32 $146,222.33 30324 SF Warehous, TSDC-Imp 1 150 0.56 $8,905 $4,987 30.32 $110,594.32 TSDC-Reim 1 150 0.56 $514 $288 30.32 $6,383.55 TSDC-RT 1 0 $0 0.00 $0.00 TDT 2 0 $0 0.00 $0.00 TSDC-Imp 2 0.00 $0 $0 0.00 $0.00 TSDC-Reim 2 0.00 $0 $0 0.00 $0.00 TSDC-RT 2 $0 0.00 $0.00 Did total TSDC need to be reduced to 80%of TDT? Use 1 Yes Use 2 No Total TDT and TSDCs Former Uses $263,200 Proposed Use ITE Rate per Rate per TDT/TSDC Use# Code PHVT PHVT Unit* # Units Amount Description TDT 1 150 $4,822 29.96 $144,452.65 29957 SF Warehous, TSDC-Imp 1 150 0.56 $8,905 $4,987 29.96 $109,255.83 TSDC-Reim 1 150 0.56 $514 $288 29.96 $6,306.29 TSDC-RT 1 0.00 $0 $0 0.00 $0.00 TDT 2 110 $6,827 2.96 $20,228.40 TSDC-Imp 2 110 1.08 $8,905 $9,617 2.96 $15,299.62 2936 SF Light Ind. TSDC-Reim 2 100 1.08 $514 $555 2.96 $883.10 TSDC-RT 2 0.00 $0 $0 3.57 $0.00 TDT 3 0.00 $0.00 TSDC-Imp 3 0.00 $0 0.00 $0.00 TSDC-Reim 3 0.00 $0 0.00 $0.00 TSDC-RT 3 0.00 $0 0.00 $0.00 Did total TSDC need to be reduced to 80%of TDT? Use 1 Yes Use 2 Yes Use 3 No Total All TDTs&TSDCs Proposed Uses $296,425.90 Less: Total All TDTs &TSDCs Former Uses $263,200.19 Aek , Total All TDTs&TSDCs Net Increase $33,225.71 C� Q'-0 Total Net County TDT $18,458.73 J /`&C°111) "' Total Net TSDC-Imp $13,961.14 Total Net TSDC-Reim $805.84 Total Net TSDC RT Overlay $0.00 TDT TSDC Imp+ Reim Target Recovery Rate 28.0% 30% Estimated Total Impact $65,924 $49,223 Estimated Unmitigated Impact $47,465 $34,456 All TDT&TDSC TSDC RT Overlay Target Recovery Rate 29% 30% Estimated Total Impact $115,147 $0 Estimated Unmitigated Impact $81,922 $0 TDT=County Transportation Development Tax TSDC Citywide=City of Tigard Transportation System Development Tax(TSDC-Imp&TSDC-Reim) TSDC RT=River Terrace Transportation System Development Tax Overlay Extended Combination SDC Calculator-091018-I:\Community Development\Permit Coordinator\SDC Calculators Sxaat � z< l S4 I Y{1i t�if Y 45; 4t.; � k, tXf, q•; qt f q� Parks Estimate 5/17/2022 BUP2022-00101/ 13240 SW Wall St AML ALL PARKS RATES EFFECTIVE 7/1/21 Q Yes Project is in River Terrace ? 0 No Note: All Neigh-Imp# Units entries=0 if project is in River Terrace; All Neigh-RT# Units entries=0 if project is elsewhere in the city. Former Use Rate Type Use# ITE Code # Units Rate Parks Amount Description Parks-Imp 1 150 12.1 $542 $6,558.20 30324 SF Warehouse Parks-Reim 1 150 12.1 $99 $1,197.90 0 Neigh-Imp 1 150 $0 $0.00 0 Neigh-RT 1 $0 2 $0 Total Parks Former Uses $7,756 Proposed Use Use# ITE Code # Units Rate Parks Amount Description Parks-Imp 1 150 15.35 $542 $8,319.70 29957 SF Warehouse Parks-Reim 1 150 15.35 $99 $1,519.65 0 Neigh-Imp 1 150 15.35 $0 $0.00 0 Neigh-RT 1 $0.00 Parks-Imp 2 $0.00 Parks-Reim 2 $0.00 2936 SF Light Ind. Neigh-Imp 2 $0.00 0 Neigh-RT 2 $0.00 0 Parks-Imp 3 $0.00 Parks-Reim 3 $0.00 Neigh-Imp 3 $0.00 Neigh-RT 3 $0.00 Total Parks Outside RT Proposed Uses $0.00 Less: Total Parks Outside RT Former Uses $0.00 Total All Parks Outside RT Net Increase $0.00 t'E Total Parks RT Proposed Uses $0.00 Less: Total Parks RT Former Uses $0.00 Total All Parks RT Net Increase Total Parks-Imp $1,761.50 Total Parks-Reim $321.75 Total Neigh-Imp $0 No Neigh-Imp Total Neigh-RT $0 No Neigh-RT 4} For Non-Residential Calculations: Prior Use: Warehousing=2500sf/EE; 30324/2500=12.1EEs. Proposed Use: warehouse/light industrial=2500/ EE= warehouse/850/EE= Light Industrial Warehouse: 11.9/L.Industrial: 3.5 Parks-Imp=Parks Improvement,Citywide including River Terrace Parks-Reim=Parks Reimbursement,Citywide including River Terrace Neigh-Imp=Neighborhood Parks Improvement Outside River Terrace Neigh-RT=Neighborhood Parks Improvement Inside River Terrace TDT & TSDC Discounts 5/17/2022 BUP2022-00101/ 13240 SW Wall St AML Adjustment for TDT Change-in-Use Discount Building Age: 20 Years (2001) $164,681.06 TDT Proposed Use $146,222.33 TDT Prior Use $18,458.73 TDT Pre-Discount 32,920 Total Square Feet (Enter) 2,596 Square Feet Eligible for Discount Enter) 7.89% Eligible as%of Total Square Feet $1,455.62 TDT on eligible sq.ft. 15 Age of Building (Enter) 50% Percentage discount $727.81 Discount: 75%/20 years; 50%/3 years. $17,730.92 Revised TDT Post-Discount Adjustment to TSDC if greater than 80% of TDT $131,744.84 Total TSDC Proposed Use $116,977.86 Total TSDC Prior Use $14,766.98 Total TSDC Pre-Discount Yes Does 80% maximum TSDC Apply? $14,184.74 Total TSDC Post-Discount Plus Application of TOD Discount if Relevant. Enter amount of TOD Discount, if any. $13,961 Revised TSDC-I after TOD $806 Revised TSDC-R aafter TOD $0 Revised TSDC-RT after TOD $14,767 Net Revised Total TSDC after TOD -$582 TOD Discount fi $32,498 Revised Total TDT&TSDC after TOD Total TSDC-1 Pre-80% Discount $13,961.14 Total TSDC-R Pre-80% Discount $805.84 s s' TOTAL $14,766.98 " Total TSDC Post-80% Discount Revised TSDC-I $13,410.67 Revised TSDC-R $774.07 $14,184.74 CleanWater Services SENSITIVE AREA PRE-SCREENING SITE ASSESSMENT Clean Water Services File Number 22-000332 1. Jurisdiction: Tigard 2. Property Information (example: 1S234AB01400) 3. Owner Information Tax lot ID(s): Name: Wall Street Industrial LLC 2S101 CA LOT 200 Company: Agilyx (tenant) Address: 13240 SW Wall Street OR Site Address: 13240 SW WALL STREET City, State,Zip: Tigard, Oregon, 97223 City, State,Zip: TIGARD, OREGON, 97223 Phone/fax: 503-740-7340 Nearest cross street: SW HUNZIKER ST Email: andrew.swartwout@agilyx.com 4. Applicant Information 4. Development Activity(check all that apply) ❑ Addition to single family residence(rooms, deck, garage) Name: Rebecca Kerr ❑ Lot line adjustment 0 Minor land partition Company: CIDA Inc. ❑ Residential condominium ❑ Commercial condominium Address: 15895 SW 72nd Ave ❑ Residential subdivision 0 Commercial subdivision City, State,Zip: Portland , Oregon, 97224 © Single lot commercial ❑ Multi lot commercial Phone/fax: 503-226-1285 Other Email: rebeccak@cidainc.com 6. Will the project involve any off-site work? ❑Yes 0 No 0 Unknown Location and description of off-site work: 7. Additional comments or information that may be needed to understand your project: This application does NOT replace Grading and Erosion Control Permits,Connection Permits, Building Permits, Site Development Permits, DEQ 1200-C Permit or other permits as issued by the Department of Environmental Quality, Department of State Lands and/or Department of the Army COE. All required permits and approvals must be obtained and completed under applicable local,state,and federal law. By signing this form, the Owner or Owner's authorized agent or representative, acknowledges and agrees that employees of Clean Water Services have authority to enter the project site at all reasonable times for the purpose of inspecting project site conditions and gathering information related to the project site. I certify that I am familiar with the information contained in this document, and to the best of my knowledge and belief, this information is true, complete, and accurate. Print/type name Rebecca Kerr Print/type title Associate Architect Signature ONLINE SUBMITTAL Date 1/20/2022 FOR DISTRICT USE ONLY ❑ Sensitive areas potentially exist on site or within 200'of the site.THE APPLICANT MUST PERFORM A SITE ASSESSMENT PRIOR TO ISSUANCE OF A SERVICE PROVIDER LETTER. If Sensitive Areas exist on the site or within 200 feet on adjacent properties,a Natural Resources Assessment Report may also be required. ❑ Based on review of the submitted materials and best available information sensitive areas do not appear to exist on site or within 200'of the site.This Sensitive Area Pre-Screening Site Assessment does NOT eliminate the need to evaluate and protect water quality sensitive areas if they are subsequently discovered.This document will serve as your Service Provider Letter as required by Resolution and Order 19-5, Section 3.02.1,as amended by Resolution and Order 19-22.All required permits and approvals must be obtained and completed under applicable local, State and federal law. ® Based on review of the submitted materials and best available information the above referenced project will not significantly impact the existing or potentially sensitive area(s)found near the site.This Sensitive Area Pre-Screening Site Assessment does NOT eliminate the need to evaluate and protect additional water quality sensitive areas if they are subsequently discovered.This document will serve as your Service Provider Letter as required by Resolution and Order 19-5, Section 3.02.1, as amended by Resolution and Order 19-22.All required permits and approvals must be obtained and completed under applicable local,state and federal law. ❑ THIS SERVICE PROVIDER LETTER IS NOT VALID UNLESS CWS APPROVED SITE PLAN(S)ARE ATTACHED. ❑ The proposed activity does not meet the definition of development or the lot was platted after 9/9/95 ORS 92.040(2). NO SITE ASSESSMENT OR SERVICE PROVIDER LETTER IS REQUIRED. Reviewed by — L./2da-421-- Date 2/7/22 Once complete,email to: SPLReview@cleanwaterservices.org • Fax: (503) 681-4439 OR mail to: SPL Review,Clean Water Services, 2550 SW Hillsboro Highway, Hillsboro, Oregon 97123 Revised 2/2020 Main Office • 2550 SW Hillsboro Highway • Hillsboro, Oregon 97123 • p: 503.681.3600 f: 503.681.3603 cleanwaterservices.org ////\ / , CV 41.441% 6___+ / MSHNC • v-ist /, ,/ \ j sKor r ///' \ / 5172 ay \\`` i' s • i Y / \ gAtEg \... r \ \ •-• I . . • -,• A . . 2 .1 'q S. 8 8 \ O •�/ �z EQUIPMENT PAD-SOUTH ELEVATION I., i/ ,S0 \ A „ 22 GA 112-7:2 '\ ( \\ &\,N, °), . > i 61 / \ .�i IV''All' 1 1 11 `\ 81 illIIIIV1j11� LIJ I= „ Ma, I 1= W \� ►i /� III il[ P.M F ii f y -tom ��+� W *v° \\\` /' 2� U .y \\ ��, 1 BOLLARD DETAIL ©FLASHING DETAIL W a. \ Ns COMMOUS WI CATION OF N GALVAIGIZED STOW MLA, / NV/CRAW DOPRID ( 1 KOWtil PMECT X MOWN J *09 ARCHITECTURAL SITE PLAN-FOR REFERENCE ONLY KEYNOTES LEGEND 711111.1M,0 G272217,12-R 0 SECONDAF17 0211•29,r21-227rvta A tatia.72 17009 tocAnoG9 ....11111117 < O M p I eeisvD-.1,01 psr r STRUCIIJPAL 0 A0.1 � 0. STACK FLASHING DETAL 0 wn sin frm... 0 t.., 71 City of Tigard : . ii COMMUNITY DEVELOPMENT DEPARTMENT r1cARa Building Permit Review - Commercial - With Land Use o Building Permit #: I(JL Oz2.0)((0 I Site Address: I3 2MO SW' ilitta (r-k Suite/Bldg#: Project Name: 1 C K (Name comercial business occupying the space. If vacant,enter Spec Space.) Planning Review /� Proposal: 4-0A pas s, i I/blt t' 4/4 Verify site address/suite# exists and active in permit system. ❑ River Terrace Neighborhood: ❑ Yes ,®7 No L Land Use Case #: Al iti O24 2-2..-(06101'1 ig Plans Match Approved Land Use: rSite Plan ❑ Landscape Plan ❑ Other: ❑ Urban Forestry Plan ❑ Elevation Plan d� Iylmlrn-Heigbt n ,, i uo i} arrtditions Met. ❑ r or to u mltta r or snit Issuance 4 Business License: Exists: A Yes ❑ No,applicant was provided a business license application igi Public Facilities Improvement (PFI) Permit: Required: ❑ Yes, applicant was notified 4 No Applied For: ❑ Yes ❑ No,stop intake Notes: Approved by Planning: A-eakl Date: 14/6 f 2...2. Revisions (after Building Submittal only) Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: ❑ Approved ❑ Not Approved Revision 3: ❑ Approved ❑ Not Approved Building Permit Submittal Original Submittal Date: q 14 Site Plans: # •j Building Plans: # Building Permit#: [enter building permit#above. Workflow Routing: E Planning L1'Engineering E 1 rmit Coordinator E Suilding Workflow Sign-off: EW Sign-off for Planning(include notes from planning review) Route Application Documents: V.--Building: original permit application, site plans,building plans, engineer and beam calculations and trust details,if applicable, etc. Notes: By Permit Technician: .--' 0 Date: O'j�Q/�1ILL- I:\Building\Fonns\BldgPennitRvw COM WithLandUse 111819.docx Eairn► Engineering Review [ Sfope at building pad: .920 ,.B'PFI Permit#: Conditions "Met"prior issuance of building permit YJ Easements (encroachments)per engineering conditions of approval and plat(not typical on SDR/CUP) IQ Water Quality/Quantity Facility: - : Assess Water Quality Fee in-lieu: ❑ Yes 2---No Assess Water Quantity Fee in-lieu: ❑ Yes 1?-"No LIDA Facility on lot: ❑ Yes 12". o . Add Fee: ❑ Yes D No ❑ NOT Approved by Engineering: Date Notes: - < Approved by Engineering: K, (-i s..,-fit_ Date: �-4..-Za Z'-e_ Revisions (after Building Submittal only) Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: ❑ Approved ❑ Not Approved Revision 3: ❑ Approved ❑ Not Approved 1Per it Coordinator Review Conditions "Met"prior to issuance of building permit ❑ Approved,NOT Released: Date: Notes: Revisions (after Building Submittal only) Revision Notice 1: Date Sent to Applicant: Revision Notice 2: Date Sent to Applicant: Revision Notice 3: Date Sent to Applicant: ^- SDC Fees Entered: Wash Co Trans Dev Tax: Yes ❑ N/A Tigard Trans SDC: gr1Yes ❑ N/A Parks SDC: !i Yes ❑ N/A LIDA Fee: ❑ Yes /N/A —1:;1- OK to Issue Permit Approved by Permit Coordinator: zir: Date: 6 (ciI1A tit' I:\Building\Forms\BldgPermitRvw_COM_WithLandUse_111819.docx RECEIVED Minor Modification DEC 0 9 2021 61 Date: 1/5/2022 (revised 3/1/2022) BUILDING DIVISION Subject: Narrative for Minor Modification CITY OF NO Project Name: Agilyx Research and Development Center Project No: 210015.02 15895 SW 72ND AVE By: Rebecca Kerr SUITE 200 To: Sean Vermilya, Clty of Tigard Planning Department PORTLAND, OR 97224 PHONE:503.226.1285 The Minor Modification proposed is for a new Research and Development Center in an existing FAX:503.226.1670 factory. Work consists of an interior tenant improvement with an exterior covered mechanical INFO@CIDAINC.COM pad located adjacent to one of the labs and an exterior generator located on a separate pad. None of the exterior work can be viewed from the street. New ADA parking is being installed WWW.CIDAINC.COM for the tenant as none currently exists. The building is currently occupied as F-I, S-I and B there is no change in occupancy and a reduction in occupant load. 18.765.060 Minor Modifications A. Definition. A minor modification has the following characteristics: I. It has minimal impacts on surrounding properties, sensitive lands, or public facilities; and 2. It does not cause the development to go out of conformance with any applicable standard or further out of conformance if already nonconforming, except where an adjustment has been approved. Response:The only change to the site is to the addition of ADA parking stalls. All other exterior work has been eliminated or moved to the interior. This has no impact on the sensitive lands, surrounding properties, or public utilities. 18.320.040 Development Standards D. Utilities and service areas I. Private utility facilities, such as transformers or control valves, that serve a single development must be located below ground unless the functional properties of the facility require above ground placement. If located above ground, all facilities 1 cubic foot or greater in volume or with any one dimension greater than 2 feet must meet the following standards where not wall-or roof-mounted or located inside a building: a. the facility may not be located within 20 feet of any street property line; and b. the facility must be dark in color and painted or wrapped with a non- reflective material. Response: Due to the revisions this is Not Applicable 18.4 10.030 Off-Street Parking and Loading General Provisions D. Mixed-used and multi-tenant developments. In mixed use and multi-tenant developments, the required minimum vehicle parking is determined using the following formula ARCHITECTURE I. The use category with the largest proportion of total floor area within the ENGINEERING development must provide 100 percent of the minimum vehicle parking required for that use category in section 18.4 10.070 PLANNING INTERIORS `ta p 2. The use category with the second largest proportion of total floor area within the 411(1 development must provide 85 percent of the minimum vehicle parking required for that use category 3. The use category with the third largest proportion of total floor area within the development must provide 70 percent of the minimum vehicle parking required for that use category 4.All other use categories must provide 60 percent of the minimum vehicle parking required for each of those categones F.Accessible parking. All parking areas must include the required number of accessible parking spaces as specified by the state building code and federal standards, Such parking spaces must kSr = be sized, signed, and marked as required by these regulations and in compliance with ORS 447 15895 SW 72ND AVE SUITE 200 Response: Using the formula above, 98 required vehicle parking spots have been calculated for i ? the four different tenants on this site. In depth calculations are shown on sheet CS I.There are PORTLAND, OR 97224 currently 102 existing vehicle parking spots on this site. 100 total spots are proposed when PHONE:503.226.1285 adding 3 ADA accessible parking spots in front of Agilyx. FAX:503.226.1670 INFO@CIDAINC.COM WWW.CIDAINC.COM • �y. 34 �k{ �{ S }yyAp� �FS;< 5�1 S Y �5' k 6 *^ yi kSyY , ARCHITECTURE ENGINEERING PLANNING INTERIORS