Report City of Tigard 51-2022-00 02
Building Division
• 13125 SW Hall Blvd, Tigard, OR 97223
Phone: 503.718.2439 Fax: 503.598.1960
TIGARD Inspection Line: 503.639.4175 MAY 9 2022
www.tigard-or.gov CITY OF TIGARD
BUILDING DIVISION
2010 Oregon Solar Installation Specialty Code
Check List for Prescriptive Installation of Roof-Mounted
PhotoVoltaic Solar Panel System
Property Information
Installation Address: 16793 SW Birdsong St, Beaverton, Oregon, 97007
City: Zip:
Owner's Name: Max Liu Date: 04 / 29 / 2022
Contractor's Name: BRS Field Ops, LLC CCB #: 227185
Design Parameters of the Property/Structure
If"Yes", does not
Flood Hazard Is the installation Yes qualify for the
Area Located in a flood prescriptive path, follow
plain/flood way? No OSSC or ORSC for
design requirements.
Is the wind exposure Yes If"Yes", qualifies for
Wind Exposure "C" or less? I I No the prescriptive path.
Installations on detached Is the Ground Snow
single/two-family Load 70 psf or less?
dwelling/single/two- If"Yes", qualifies for
family townhomes Yes the prescriptive path.
and/or their accessory
Ground structures. f] No
Snow Load Is the Ground Snow
Installations on all Load 50 psf or less?
structures other than If"Yes", qualifies for
above
��1 Yes the prescriptive path.
No
1
1:/Building/Forms/PhotoVoltaic-Checkl ist02-0I-I I.docx
Is the construction
material wood and does �`�� Yes
Type of the construction qualify If"Yes", qualifies for
Construction as "conventional light I I No the prescriptive path.
frame"construction?
Is the spacing 24 inches
or less?
Pre-engineered trusses. E Yes If"Yes", qualifies for
the prescriptive path.
❑ No
Roof framing
members Is the spacing 24 inches
or less?
If"Yes", qualifies for
Nominal lumber. Q Yes the prescriptive path.
II No
Is the combined weight ICJ Yes
of the PV modules and If"Yes", qualifies for
racking less than or No the prescriptive path.
Solar equal to 4.5 psf?
installation Is the solar installation
layout in accordance Yes
with Section 305.4(3) of If"Yes", qualifies for
the 2010 Oregon Solar n No the prescriptive path.
Code?
❑ Metal
Single layer If roofingmaterial is
of wood
Roofing Check the type of n one of the three types
material roofing material shingle/shake checked, qualifies for
Max. two layers
the prescriptive path.
E of composition
shingle.
Is the roof mounted Yes
Connections of solar assembly
If"Yes", qualifies for
the solar assembly connected to roof No the prescriptive path.
to the roof framing or blocking
directly?
2
1:/Building/Forms/PhotoV oltaic-Checklist02-01-I I.docx
❑ Yes If"Yes", qualifies for
Is the gauge 26 or less?
❑ No the prescriptive path.
115 lbs for 60 inch
spacing or less?
If"Yes", qualifies for
Yes the prescriptive path.
No
Minimum Uplift rating
of Clamps? 75 lbs for 48 inches
spacing or less?
If"Yes", qualifies for
Yes the prescriptive path.
No
Attachment of
roof mounted Minimum 24 inches If the spacing falls
solar systems Spacing of clamps? within 24 inches and 60
directly to inches Maximum 60 inches inches, qualifies for the
standing seam prescriptive path.
metal panels If the width of the panel
Width of roofing is less than 18 inches,
panels? 18 inches or less
inches qualifies for the
prescriptive path.
Minimum#10 at 24
inches o/c?
Size and spacing of If"Yes", qualifies for
fastener? Yes the prescriptive path.
IINo
Is the roof decking of
WSP min. ''/2" thickness, ❑ Yes
decking connected to If"Yes", qualifies for
framing members No the prescriptive path.
w/min. 8d nails @
6"/12" o/c?
Is the height less than or
Maximum 18 inches equal to 18 inches?
Height of the from the top of the If"Yes", qualifies for
module to the roof ❑� Yes the prescriptive path.
solar modules p p
surface. I I No
3
l:/Bui(ding/Forms/PhotoVoltaic-Checklist02-01-11.docx
Submittal Documents required for Prescriptive Installations
Show the location of the PV system in relation to buildings, structures,
property lines, and, as applicable, flood hazard areas.
Site Plan Details must be clear and easy to read.
Minimum size of the plan is 8.5 x 11 inches.
Attach a simple structural plan showing the roof framing (rafter size, type, and
spacing) and PV module system racking attachment.
System must be shown in sufficient detail and clarity to assess whether it
Structural Plan meets the prescriptive construction requirements as listed earlier above in the
matrix.
Minimum size of the plan is 8.5 x 11 inches.
PV Modules
Manufacturer: REC Solar
Model Number: REC400AA Pure
Listing Agency: CSA
Wyk
4