Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report (2)
23M- OFFICE COPY 5(o perTce 0 TRANS® RECEIVED MAY 16 202Z CITY OF TIGARD BUILDING DIVISION Product Data Split System Cooling 4TTR3018H1000N 4TTR3024H1000N .....111111111111111111111.11°- 4TTR3030H1000N __ 4TTR3036H1000N == 4TTR3042E1000N 4TTR3043A1000N _= - __ 4TTR3048E1000N __ -_- - 4TTR3048E1000P _ 4TTR3049A1000N 4TTR3060E1000N June 2020 22-1842-8R-EN 1 R ^ N TECHNOLOGIES 0 TRANS® Outline Drawing It/ '' ...1' SERVICE PANEL 0�Ili ELECTRICAL COMPONENT CLEARANCES `\ // PER PONENT CLEARANCES `\ PER PREVAILING CODES \I,_�� ' TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1524(5 FEET) ABOVE UNIT UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT AND SHOULD BE AT LEAST 305(12")FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHERTWO SIDES UNRESTRICTED 1 1 oiiiiritiliti litlii ELECTRICAL SERVICE - K PANEL 25)1) _22.2(7B)DIA.HOLE �' A LOW VOLTAGE i ��I 28.6)1-1/8)DIA.K.O.WITH I I 22.2(7/81 DIA.HOLE IN CONTROL I �� BOX BOTTOM FOR ELECTRICAL �,�} POWER SUPLY ■"IC; LIQUID LINE SERVICE VALVE, 1I . H F i1 I.D.FEMALE BRAZE linw1�4 jA CONNECTION WITH 1/4"SAE FLARE PRESSURETAP FITTINGS G J_ 1 FI .7 1 K.O.FOR ALTERNATE ELECTRICAL ROUTING From Dwg.0152898 -- GAS LINE 1/4TURN BALL SERVICE VALVE, D.. I.D.FEMALE BRAZED CONNECTION WITH 1/4"SAE FLARE PRESSURE TAP FITTING.A Model Base A B C D E F G H J K 4TTR3018H 2 730 724 651 3/4 3/8 127 57 194 38 457 (28-3/4) (28-1/2) (25-5/8) (5) (2-1/4) (7-5/8) (1-1/2) (18) 4TTR3024H 2 730 724 651 3/4 3/8 137 65 210 57 457 (28-3/4) (28-1/2) (25-5/8) (5-3/8) (2-5/8) (8-1/4) (2-1/4) (18) 4TTR3030H 2 730 724 651 3/4 3/8 137 65 210 57 457 (28-3/4) (28-1/2) (25-5/8) (5-3/8) (2-5/8) (8-1/4) (2-1/4) (18) 41TR3036H 3 730 829 756 3/4 3/8 137 79 197 60 508 (28-3/4) (32-5/8) (29-3/4) (5-3/8) (3-1/8) (7-3/4) (2-3/8) (20) 4TTR3042E 3 730 829 756 7/8 3/8 152 98 219 86 508 (28-3/4) (32-5/8) (29-3/4) (6) (3-7/8) (8-5/8) (3-3/8) (20) 4TTR3043A 4.2 741 946 870 7/8 3/8 152 98 219 86 508 (29-1/8) (37-1/4) (34-1/4) (6) (3-7/8) (8-5/8) (3-3/8) (20) 933 829 756 152 98 219 86 508 4TTR3048E 3 (36-3/4) (32-5/8) (29-3/4) 7/8 3/8 (6) (3-7/8) (8-5/8) (3-3/8) (20) 4TTR3049A 4.2 741 946 870 7/8 3/8 152 98 219 86 508 (29-1/8) (37-1/4) (34-1/4) (6) (3-7/8) (8-5/8) (3-3/8) (20) 4TTR3060E 4.4 943 946 870 7/8 3/8 152 98 219 86 508 (37-1/8) (37-1/4) (34-1/4) (6) (3-7/8) (8-5/8) (3-3/8) (20) 2 22-1842-8R-EN 9 TRANS® Product Specifications Model No.(a) 4TTR3018H1000N 4TTR3024H1000N 41TR3030H1000N POWER CONNS.—V/PH/HZ(b) 208/230/1/60 208/230/1/60 208/230/1/60 MIN.BRCH.CIR.AMPACITY 12 18 16 BR.CIR.PROT.RTG.—MAX.(AMPS) 20 30 25 COMPRESSOR CLIMATUFF®-SCROLL CLIMATUFF®-SCROLL CLIMATUFF®-SCROLL RLAMPS—LRAMPS 9-48 12.8-58.3 12.3-63 Outdoor Fan FL AMPS 0.64 0.64 0.9 Fan HP 1/8 1/8 1/8 Fan Dia(inches) 23.0 23.0 18.9 Coil SPINE FINTM SPINE FINTM SPINE FINTM Refrigerant R-410A 4 LBS.,2 OZ 4 LBS.,2 OZ 4 LBS.,2 OZ LINE SIZE—IN.O.D.GAS(c) 3/4 3/4 3/4 LINE SIZE—IN.O.D.LIQ.(C) 3/8 3/8 3/8 Charge Spec.Subcooling 10°F 10°F 10°F Dimensions H x W X D Crated(IN.) 34 x 30.1 x 33 34 x 30.1 x 33 30 x 27 x 30 Weight—Shipping(lbs.) 167 169 157 Weight—Net(lbs.) 140 142 137 Optional Accessories: Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control AY28X079 AY28X079 AY28X079 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 Extreme Condition Mount Kit BAYECMT023 BAYECMT023 BAYECMT023 Start Kit BAYKSKT263 BAYKSKT263 BAYKSKT263 Crankcase Heater Kit BAYCCHT302 BAYCCHT302 BAYCCHT302 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM 103 BAYLOAM 103 BAYLOAM 103 Service Valve Panel Cover - - - Refrigerant Lineset(d) (a) Certified in accordance with the Unitary Air-conditioner equipment certification program which is based on AHRI standard 210/240. (b) Calculated in accordance with N.E.C.Only use HACR circuit breakers or fuses. (c) Standard line lengths—60',Standard lift—60'Suction and Liquid line.For Greater lengths and lifts refer to refrigerant piping software Pub#32-3312-0*(*denotes latest revision). (di 25,30,35 and 50 foot linesets available.For a complete listing of lineset options available from equipment or supply stores, refer to the Trane Residential and Light Commercial Product Handbook. 22-1842-8R-EN 3 0 TRAM' Product Specifications Model No.(a) 4TTR3036H1000N 4TTR3042E1000N 4TTR3043A1000N POWER CONNS.—V/PH/HZ(b) 208/230/1/60 208/230/1/60 208/230/1/60 MIN.BRCH.CIR.AMPACITY 18 22 22 BR.CIR.PROT.RTG.—MAX.(AMPS) 30 35 35 COMPRESSOR CLIMATAUFF®-SCROLL CLIMATUFF®-SCROLL CLIMATUFF®-SCROLL RL AMPS—LR AMPS 14.1—75 17.0—124 16.7—109 Outdoor Fan FL AMPS 0.7 0.7 1.05 Fan HP 1/8 1/8 1/5 Fan Dia(inches) 23.0 23 27.5 Coil SPINE FIN", SPINE FINTM SPINE FINTM Refrigerant R-410A 4 LBS.,2 OZ 5 LBS.,2 OZ 6 LBS.,7 OZ LINE SIZE—IN.O.D.GAS(C) 3/4 7/8 7/8 LINE SIZE—IN.O.D.LIQ.(C) 3/8 3/8 3/8 Charge Spec.Subcooling 10°F 10°F 12°F Dimensions H x W X D Crated(IN.) 34 x 30.1 x 33 34 x 30.1 x 33 34.4 x 35.1 x 38.7 Weight—Shipping(lbs.) 175 200 216 Weight—Net(lbs.) 147 172 184 Optional Accessories: Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control AY28X079 AY28X079 AY28X079 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 Extreme Condition Mount Kit BAYECMT023 BAYECMT004 BAYECMT004 Start Kit BAYKSKT263 BAYKSKT263 BAYKSKT263 Crankcase Heater Kit BAYCCHT302 BAYCCHT301 BAYCCHT301 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM 103 BAYLOAM 103 BAYLOAM 103 Service Valve Panel Cover TAYSVPANL0032AA TAYSVPANL0032AA TAYSVPANL3343AA Refrigerant Lineset(d) (a) Certified in accordance with the Unitary Air-conditioner equipment certification program which is based on AHRI standard 210/240. (b) Calculated in accordance with N.E.C.Only use HACK circuit breakers or fuses. (b) Standard line lengths—60',Standard lift—60'Suction and Liquid line.For Greater lengths and lifts refer to refrigerant piping software Pub#32-3312-0*(*denotes latest revision). (d) 25,30,35 and 50 foot linesets available.Fora complete listing of lineset options available from equipment or supply stores, refer to theTrene Residential and Light Commercial Product Handbook. 4 22-1842-8R-EN 0 Product Specifications Model No.(a) 4TTR3048E1000N/P 4TTR3049A1000N 4TTR3060E1000N POWER CONNS.-V/PH/HZ lb) 208/230/1/60 208/230/1/60 208/230/1/60 MIN.BRCH.CIR.AMPACITY 28 28 27 BR.CIR.PROT.RTG.-MAX.(AMPS) 45 45 45 COMPRESSOR CLIMATUFF®-SCROLL CLIMATUFF®-SCROLL CLIMATUFF®-SCROLL RL AMPS-LR AMPS 21.8-117 21.8-117 20.8-127.1 Outdoor Fan FL AMPS 0.93 1.05 1.05 Fan HP 1/5 1/5 1/5 Fan Dia(inches) 23 23 27.5 Coil SPINE FINT" SPINE FINTM SPINE FINT" Refrigerant R-410A 6 LBS.,7 OZ 6 LBS.,7 OZ 7 LBS.,10 OZ LINE SIZE-IN.O.D.GAS(c) 7/8 7/8 7/8 LINE SIZE-IN.O.D.LIQ.)c) 3/8 3/8 3/8 Charge Spec.Subcooling 10°F 10°F 10°F Dimensions H x W X D Crated(IN.) 42 x 30.1 x 33 42 x 30.1 x 33 42.4 x 35.1 x 38.7 Weight-Shipping(lbs.) 233 212 246 Weight-Net(lbs.) 197 189 211 Optional Accessories: Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control AY28X079 AY28X079 AY28X079 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 Extreme Condition Mount Kit BAYECMT004 BAYECMT004 BAYECMT004 Start Kit BAYKSKT263 BAYKSKT263 BAYKSKT263 Crankcase Heater Kit BAYCCHT301 BAYCCHT301 BAYCCHT301 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM103 BAYLOAM103 BAYLOAM103 Service Valve Panel Cover TAYSVPANL0044AA TAYSVPANL0044AA TAYSVPANL0044AA Refrigerant Lineset(a) (a) Certified in accordance with the Unitary Air-conditioner equipment certification program which is based on AHRI standard 210/240. (b) Calculated in accordance with N.E.C.Only use HACR circuit breakers or fuses. (o Standard line lengths-60',Standard lift-60'Suction and Liquid line.For Greater lengths and lifts refer to refrigerant piping software Pub#32-3312-0*(*denotes latest revision). (a) 25,30,35 and 50 foot linesets available.For a complete listing of lineset options available from equipment or supply stores, refer to theTrane Residential and Light Commercial Product Handbook. Sound Power Level A-Weighted MODEL Sound Power Full Octave Sound Power(dB) Level(dB(A)] 63 125 250 500 1000 2000 4000 8000 Hz* Hz Hz Hz Hz Hz Hz Hz 4TTR3018H1 72 73.7 71.4 65.4 68 67.3 62.9 56 50.3 4TTR3024H1 74 47.9 60.5 64.1 71.2 71.2 69.0 58.2 51.5 4TTR3030H1 72 69.9 69.6 69.1 68.6 68.7 60.9 56.2 48.9 4TTR3036H1 68 74.7 65.0 65.2 66.4 63.6 58.7 56.3 52.8 4TTR3042E1 72 77.6 68.3 67.4 65.6 67.4 58.2 54.1 47.6 4TTR3043A1 72 77.6 68.3 67.4 65.6 67.4 58.2 54.1 47.6 4TTR3048E1 74 72.5 72.3 69.2 67.5 72.3 60.2 55.2 54.2 4TTR3049A1 74 72.5 72.3 69.2 67.5 72.3 60.2 55.2 54.2 4TTR3060E1 71 81 72 69 69 66 60 57 54 Note:Rated in accordance with AHRI Standard 270-2008*For Reference Only 22-1842-8R-EN 5 TRAM" Accessory Description and Usage Anti-Short Cycle Timer—Solid state timing device that prevents compressor recycling until five(5) minutes have elapsed after satisfying call or power interruptions. Use in area with questionable power delivery,commercial applications,long lineset,etc. Evaporation Defrost Control — SPST Temperature actuated switch that cycles the condenser off as indoor coil reaches freeze-up conditions. Used for low ambient cooling to 30°F with TXV. Rubber Isolators — Five(5)large rubber donuts to isolate condensing unit from transmitting energy into mounting frame or pad.Use on any application where sound transmission needs to be minimized. Hard Start Kit — Start capacitor and relay to assist compressor motor startup.Use in areas with marginal power supply,on long linesets,low ambient conditions,etc. Extreme Condition Mount Kit — Bracket kits to securely mount condensing unit to a frame or pad without removing any panels.Use in areas with high winds,or on commercial roof tops,etc. AHRI Standard Capacity Rating Conditions AHRI Standard 210/240 Rating Conditions 1. Cooling 80°F DB,67°F WB air entering indoor coil,95°F DB air entering outdoor coil. 2. High Temperature Heating 47°F DB,43°F WB air entering outdoor coil,70°F DB air entering indoor coil. 3. Low Temperature Heating 17°F DB air entering indoor coil. 4. Rated indoor airflow for heating is the same as for cooling. AHRI Standard 270 Rating Conditions — (Noise rating numbers are determiend with the unit in cooling operations.)Standard Noise Rating number is at 95°F outdoor air. Model Nomenclature Outdoor Units 4 T W V 0 0 3 6 A 10 0 10 10 A A �11111 r � ► ii Refrigerant Type 2=R-22 4=R-410A TRANE Product Type W=Split Heat Pump T=Split Cooling Product Family V=Variable Speed M or B=Basic Z=Leadership-Two Stage A=Light Commercial X=Leadership L=Side Discharge R=Replacement/Retail Family SEER 3=13 6=16 0=20 4=14 8=18 5=15 9=19 Split System Connections 1.6 Tons 0=Brazed Nominal Capacity in 000s of BTUs Major Design Modifications Power Supply 1=200-230/1/60 or 208-23011160 3=200-230/3/60 4=460/3160 Secondary Function Minor Design Modifications Unit Parts Identifier 6 22-1842-8R-EN 9 TRANEa Schematic Diagrams Figure 1. 1.5—3.5 Ton Models TO POWER SUPPLY PER UNIT NAMEPLATE AND LOCAL CODES I I I 1 CF FAN CAPACITOR SEE PRODUCT DATA CN WIRE CONNECTOR A r FOR OPTIONAL START il CPA COMPRESSOR Cli NIT ACCESSORY I m CR RUN CAPACITOR > CS i CS STARTING CAPACITOR M CSA-I CSA , co cc Fe) -RD- L� �f BR-o ----BK/BL44241 MS 2 CSR CAPACITOR SWITCHING RELAY R , 1 ; t B ' _ - ODT OUTDOOR THERMOSTAT BK/BL � HPCO HIGH PRESSURE CUTOUT SWITCH CAPACITOR ; LPCO LOW PRESSURE CUTOUT SWITCH [. ..C.:11.., ,) BR ORJ OR � MS COMPRESSOR MOTOR CONTACTOR TNS TRANSFORMER R BK F C H WPM CPR I IOl INTERNAL OVERLOAD PROTECTOR se THERMALLY R h ————— OM PROTECTED INTERNALLY HPCO LPCO AIRTY ICA LER L I I TYPICAL ®WARNING ®CAUTION PT¢ l'241-1 THERMOSTAT I I I HAZARDOUS VOLTAGE! USE COPPER CONDUCTORS ONLY! O I I DISCONNECT ALL ELECTRICAL Val NIT TERMINALS ARE XOT DESIGNED POWER INCLUDING REMOTE TO ACCEPT OTHER TYPES OF CONDUCTORS. Y o T I DISCONNECTS BEFORE SERVICING. Failure to do so may sure damage ia-lNS Y Y ( , Y I ----i+--�T 1 to the equipment. C-_ �./ Failure to disconnect poser before servicing can cause BL `-- I severe personal injury or --f-- YO I I death. F. - INOT-S Ill- , HEAT— IOPTlONHc ,---I-1- W3CONTROLS; I I I rtO LOR OF WIRE IREMOT BK/BLODT-§/ I ~COLOR Of WARMER 'O—FM __ W ---T— �I— - W ' 1 I BK 'I BR BLACK RD RED OR ORANGE -—-—-—I I BL BLUE RH WHITE OR GREEN ODT (OPTIONAL) (,f- {- WI-- --i—+ WI BR BROWN YL YELLOW PR PURPLE -- PN PINK -o'�O-BK I BK I L___ ___J NOTES: I. IF O0T-8 IS NOT USED. ADD JUMPER BETWEEN ANDLER. I — MUST BE MOUNTED HREMOTE OF FCONTROL OBOX BIN B ___._— _de, AM APPROVED WEATHER PROOF ENCLOSURE. B L� i I IF OOATA IS NOT USED. ADO JUMPER BETWEEN N TNS I �� WI b W2 AT AIR HANDLER. 41 --— I__R D/1np , 3. LOW VOLTAGE 124 VI FIELD WIRING MUST BE IN ANG MINIMUM. `� 4. USE COPPER CONDUCTORS ONLY; I � TO POWER SUPPLY jr 1V I FOR CANADIAN INSTALLATIONS _IPOUR INSTALLATIONS CANADIENNES PER LOCAL CODES l----T—Nv � CAUTION: NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING I50V-TO-GROUND ATTENTION:NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150 V A LA TERRE PRINTED FROM D157047P03 REVA 22-1842-8R-EN 7 0 TRANE Schematic Diagrams Figure 2. 4.0 — 5.0 Ton Models TO POWER SUPPLY PER UNIT NAMEPLATE AND LOCAL CODES I f J I / , SEE SERVICE FACTS14-1 L` en FON OPTIONAL START I KIT ACCESSORY m LEGEND °C ' CS , m MS-I ' BR C R-ICSR I MS-2m CF FAN CAPACITOR �� RD—X X I Z , _, BK/BL�XiI„� CN MIRE CONNECTOR 1 R D _—- CPR COMPRESSOR ® X BK/BL—♦ CAPACITOR CR RUN CAPACITOR OD BR CS STARTING CAPACITOR MTRr R -- 'a• CSR CAPACITOR STITCHING RELAY 8 K illiiirilliiii°R1°R CPR I ODT OUTDOOR THERMOSTAT TNERNALLY RD J on HPCO NIGH PRESSURE CUTOUT SNITCH PROTECTED I LPCO LOW PRESSURE CUTOUT SWITCH INTERNALLY MS COMPRESSOR MOTOR CONTACTOR TNS TRANSFORMER IOL INTERNAL OVERLOAD PROTECTOR OLOR Of HIRE HPCO LPCO I Al Y CHANDLER I i TYPICAL I BK/BL , 1 CrEZ THERMOSTAT —"--COLOR OF MARKER z > I I IX SLACK RD RED DR ORA$E J IL SLUE NN WRITE OR MEN O I ' NI NOON TL TELLER PR PURPLE r IOj T ' I I PK PINK 0 � ,,I Y I 0 ----Tt—_ c) I I� V� I II FOR CANADIAN INSTALLATIONS BLI , Yo I POUR INSTALLATIONS CANADIENNES I CAUTION: NOT SUITABLE FOR USE ON NOTES 112 , SYSTEMS EXCEEDING ISOV-TO-GROUND 7 (OPTION-0 GIEREMOTE I W3 CONTROLS I I ATTENTION:NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150 V A IOD O—BK-X I 4__I 0__ I—I� —_ O LA TERRE ---BK—J X �I — W2 ODT-A (OPTIONALI I —LI—0 ---1 t — --- WI ro-BK II I BK X I L_-___ i I I I I , B —+ I I B L I TNS 24V — , - rl RD-0 TO POWER SUPPLY ____ I I PER LOCAL CODES -- — •— • I_—_— J PRINTED FROM D160439P01 REVA 8 22-1842-8R-EN • TRAIIE Schematic Diagrams Figure 3. 4.0 — 5.0 Ton Models LPCO HPCO —BURL '\ 'r rgi PR FAN OA ) y=+i - BR MTR •RD I I THERMALLY NOTES: CP RR / C " PROTECTED Ci ; y INTERNALLY I. If ODT-B IS MOT USED.ADD JUMPER BETWEEN W2 B W3 AT AIR HANDLER. IF USED.DOT-B MUST BE MOUNTED REMOTE OF CONTROL BON IN AN APPROVED WEATHER PROOF ENCLOSURE. -- -�- — - -—-—'-1 2. If OUT-A IS ROT USED. ADD JUMPER BETWEEN WI S W2 AT AIR HANDLER. 3,LOW VOLTAGE 124 VI FIELD WIRING MUST BE IN AM MINIMUM. /.USE COPPER CONDUCTORS ONLYI LEGEND 21 V FACTOR} -{- RELAY CONTACT IN.01 LIRE WI R IMA CAPACITOR RELAY CONTACT IM.CI 4_,YLIRE y WING _MY/-�F THERMISTOR RDFriOR —X—L`NE V}FIELD FACTORYMWIRI WIRING GD .rN TEMP ACTUATED SNITCH SEE SERVICE FACTS X ` Q r INTERNAL OVERLOAD PROTECTION 4. SR— MAGNETIC COIL �LFOR OPTIONAL START ar PRESSURE ACTUATED SRITOS NIT ACCESSORY I y GROUND - 172 TI • JUNCTION -NJ-RESISTER OR HEATING ELEMENT Q -)I- CAPACITOR a^�n MOTs,•I NOING o BN BLI Ni!...... WIRE NUT OR CONNECTOR POL.PLW FEMALE-- 0 TERMINAL I (MALE LERYI NALSI BL OT T TN POE.PLUG MALE HOUSING I il ) I it LI 7 . TRANSFORMER IFEYAIE iEANINAL31 - I�X csRJ El TERMINAL BLOCK/BOARD � I A x x x QB N LT 1C11f ) ------6 BN_ `� s.�f TURD NOTES IA2 _ /j}r��11 OR/YL I O(REMOTE)I PTIONAL) �G/ 1/-�� BOOODD-T--JAB'}/ --- 'B m X N I B_—_ BN I GR/YL c. X `DDT-y -JnY x Cli , a -o--.(OPTIONAL) X BIN II I I I I -----------Hi—--I-- -------------------� I I `—imp 1TO POWER SUPPLY PER UNIT NAMEPLATES AND LOCAL CODES PRINTED FROM D160439P01 REVA 22-1842-8R-EN 9 9 rRANE• Mechanical Specification Options General The outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit,ten(10)feet of tested connecting line,and the smallest rated indoor evaporative coil match.This unit is designed to operate at outdoor ambient temperatures as high as 115°F.Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified.The unit is certified to UL 1995.Exterior is designed for outdoor application. Casing Unit casing is constructed of heavy gauge,galvanized steel and painted with a weather-resistant powder paint finish.The corner panels are prepainted.All panels are subjected to our 1,000 hour salt spray test. Refrigerant Controls Refrigeration system controls include condenser fan,compressor contactor and low and high pressure switches.A factory supplied,field installed liquid line drier is standard. Compressor The compressor features internal over temperature and pressure protection.Other features include:Centrifugal oil pump and low vibration and noise. Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer.The coil is protected on all four sides by louvered panels. Low Ambient Cooling As manufactured,this system has a cooling capacity to 55°F.The addition of an evaporator defrost control permits operation to 40°F.The addition of an evaporator defrost control with TXV permits low ambient cooling to 30°F. The addition of the BAYLOAM107A low ambient kit permits ambient cooling to 20°F. Thermostats—Cooling only and heat/cooling (manual and automatic change over).Sub-base to match thermostat and locking thermostat cover. i o 22-1842-8R-EN Notes 22-1842-8R-EN J TRANE Trane - by Trane Technologies (NYSE: TT), a global innovator - creates comfortable, energy efficient indoor environments for commercial and residential applications. For more information, please visit trane. com or tranetechnologies.com. AI"Claw CERTIFIED www.ahridirectory.org Unitary Small AC AHRI Standard US Standard 210/240 C CeNf aura hoot,.cat when the complete system ts Itsted `°"°°"w LISTED The AHRI Certified mark indicates Trane U.S.Inc.participation in the AHRI Certification program.For verification of individual certified products,go to ahridirectory. org. Trane has a policy of continuous data improvement and it reserves the right to change design and specifications without notice.We are committed to using environmentally conscious print practices. 22-1842-8R-EN 22 Jun 2020 Supersedes 22-1842-80-EN (April 2020) ©2020 Trane U.S. Government Federal law prohibits removal of this label before consumer purchase. ErIERCIGUIDE Furnace Trane and American Non weatherized Standard Heating & Air Conditioning Natural Gas Model: S9X2BO60D3PSBAB Efficiency Rating (AFUEr 4A+C 1 6717 950CITY OF TIGARCD BUILDING DIVISION . For energy cost info, visit 80.0 98.7 productinfo.energy.gov Least Efficient Most Efficient Range of Similar Models *Annual Fuel Utilization Efficiency PPP11111497A7 ENERGY STAR D344787P01