To: David Young
From: Ibrahim Jaalouk
CC:
Date: May 26,2022 Job#: 2143
Re: Inspection
Hello,
The following is a response to a failed inspection report by Inspector.
ITEM SI:
All windows with a single trimmer are 5'-0"or less are structurally acceptable.
ITEM S2:
Beam per plan was supposed to be installed as dropped.However,contractor installed the beam top of
wall with existing trusses hanging from its side.It is structurally acceptable as installed.
ITEM S3:
Each gable end has one brace at midspan.Contractor to add(2)more braces at each gable end per
detail 2/S4 on each side of the existing brace.
Please call our office if you have further questions.