Permit n II
CITY OF TIGARD MASTER PERMIT
II COMMUNITY DEVELOPMENT Permit#: MST2022 00120
Date Issued: 05/31/2022
TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S106DA10400
Jurisdiction: Tigard
Site address: 16944 SW BIRDSONG ST
Subdivision: RIVER TERRACE EAST Lot: 104
Project: Nandi
Project Description: Rooftop Solar PV. 7.665 kw
BUILDING
Floor Areas Required Setbacks Required
Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left 0 Parking Spaces: 0
Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke
Dwelling Units: 0 Third: 0 sf Right: 0 Detectors:
Total: 0 sf Value: $20,000.00 Rear: 0
PLUMBING
Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0
Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0
Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0
Catch Basins: 0
Bckflw Prevntr: 0
Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0
Drywell-Trench Drain: 0 Other Fixtures: 0
Other Fixture Units:
MECHANICAL
Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0
Heat Pump: N Hoods: 0 Other Units: 0
Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0
Furn>=100 K: 0
ELECTRICAL
Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits
1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0
Ea add9 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0
Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0
601-1000 amp: 0 601+amp-1000v: 0
1000+amp/volt: 0
ELECTRICAL-RESTRICTED ENERGY
SF Residential
Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All
N
Other Y Other Description: Roof top solar array 7.665 kW Ecompasing:
BUILDING INFO
Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet:
OTR SF VB R-3 0
Owner: Contractor:
NANDI,AMIT NATIONAL SOLAR INC Required Items and Reports(Conditions)
BHAUMIK,SAGARIKA 2709 NW CROSSING DRIVE
16944 SW BIRDSONG ST BEND,OR 97703
BEAVERTON,OR 97007
PHONE: PHONE: 253-359-1444
FAX:
Total Fees: $356.69
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work
will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more
the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR
QS9-nM_nnin rhrnirnh nAp Qc9-nn1-nnan vnii mw nhfaln a rnnv of the rill rilloc nr dirort nilocsnnc to ni inir by rnuinn Sn'2 9'29 10R7 nr 1 Ann 1'19 914A
Issued By: N0-U,y Va.w De,Wee, Permittee Signature: Ow Atop- r ct4-Lo-w
Call 503.639.4175 by 7:00 a.m.for the next available inspection date.
This permit card shall be kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the lob site at the time of each inspection.
la:
Building Permit ApplicatiECEIVED
Residential APR 2022 FOR OFFICE USE ONI.1
City of Tigard Received
Date/By: 5 3 2 Permit No.: e�
i N • 13125 SW Hall Blvd.,Tigard,OR 972i2z1►Y OF TIGARD Plan Review TE' � oo'2�
111 Phone: 503.718.2439 Fax: 503.59 J DING DIVISION Date/By: 'L"1/ / Other Permit:
i I G A R D Inspection Line: 503.639.4175 Date Ready/By: �22 `i Jur' ® See Page 2 for
Internet: www.tigard-or.gov Notified/Meth j / Irsz Supplemental Information
TYPE OF WORK '' QUIRED DATA:1-AND 2-FAMILY DWELLING
0 New construction ❑Demolition Permit fees*are based on the value of the work performed.
Indicate the value(rounded to the nearest dollar)of all
®Addition/alteration/replacement ®Other:Solar equipment,materials,labor,overhead,and the profit for the
CATEGORY OF CONSTRUCTION work indicated on this application.
Valuation: $20
® 1-and 2-family dwelling 0 Commercial/industrial
000
❑Accessory building 0 Multi-family Number of bedrooms:
❑Master builder 0 Other: Number of bathrooms:
JOB SITE INFORMATION AND LOCATION Total number of floors:
Job site address:16944 SW Birdsong St. New dwelling area: square feet
City/State/ZIP:Tigard, OR 97007 Garage/carport area: square feet
RSuite/bldg./apt.no.: Project name:Solar for Nandi Covered porch area: square feet
Cross street/directions to job site: Deck area: square feet
NE of the intersection of SW Roy Rogers Rd and SW Appledale Rd. Other structure area: square feet
REQUIRED DATA:COMMERCIAL-USE CHECKLIST
Subdivision: 1 Lot no.: Permit lees*are based on the value of the work performed.
Tax map/parcel no.:2S106DA10400 Indicate the value(rounded to the nearest dollar)of all
equipment,materials,labor,overhead,and the profit for the
DESCRIPTION OF WORK work indicated on this application.
Installing 7.665kw solar pv system on roof of home. 21 REC 365TP Valuation: $
modules, 10 Chilicon CP720 microinverters and 1 CP250 micro. Existing building area: square feet
New building area: square feet
® PROPERTY OWNER 0 TENANT Number of stories:
Name:Amit Nandi Type of construction:
Address:16944 SW Birdsong St. Occupancy groups:
City/State/ZIP:Tigard, OR 97007 Existing:
Phone:(971 )409-8316 Fax:( ) New:
® APPLICANT ® CONTACT PERSON BUILDING PERMIT FEES*
(Please refer to fee scheduke
Business name:National Solar
Structural plan review fee(or deposit):
Contact name:Lynnette Harley
FLS plan review fee(if applicable):
Address:13521 174th St. Ct. E.
Total fees due upon application:
City/State/ZIP:Puyallup, WA 98374
Amount received:
Phone:(253-)359-1444 Fax::( )
E-mail:Ldharley@comcast.net PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES*
CONTRACTOR Commercial and residential prescriptive installation of
roof-top mounted Photo Voltaic Solar Panel System.
Business name:National Solar Submit two(2)sets of roof plan with connection details
and fire department access,along with the 2010 Oregon
Address:2709 NW Crossing Drive Solar Installation Specialty Code checklist.
(includes plan review $180.00
City/State/ZIP:Bend, OR 97703 Permit Feeand administrative fees):
Phone:(253-)359-1444 Fax:( 877.)785-2582 State surcharge(12%of permit fee): $21.60
CCB lic.:186224 Total fee due upon application: $201.60
Authorized signature: 7/6-4-17-
This permit application expires if a permit is not obtained
within 180 days after it has been accepted as complete.
Print name: *Fee methodology set by Tri-County Building Industry
Lynnette arley Date:4/22/2022 Service Board.
I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(I 1/02/COM/WEB)
,4r -
Building Permit Application Checklist
One- and Two-Family Dwelling FOR OFFICE USE ONl.1
City of TigardIII Received
Permit No.:
■ 13125 SW Hall Blvd.,Ti d,OR 97223 y
� Associated permits:
Phone: 503.718.2439 Fax: 503.598.1960
24-Hour Inspection Line: 503.639.4175 0 Electrical Cl Plumbing ❑ Mechanical
TIGARI) Internet: www.tigard-or.gov ❑ Other:
THE FOLLOWING ITEMS ARE REQUIRED FOR PLAN REVIEW Ves No N/A
I Land use actions completed. See jurisdiction criteria for concurrent reviews. ❑ ❑ ='
2 Zoning. Flood plain,solar balance points,seismic soils designation,historic district,etc. ❑ 0 IR
3 Verification of approved plat/lot. 0 ❑ El
4 Fire district approval required. Name of district: . ❑ ❑ E
5 Septic system permit or authorization for remodel. Existing system capacity CI
6 Sewer permit. ❑ ❑ El
7 Water district approval. 0 ❑ EN
8 Soils report. Must carry original applicable stamp and signature on file or with application. 0 ❑ 183
9 Erosion control ❑plan 0 permit required. Include drainage-way protection,silt fence design and location of catch- ❑ ❑ EI
basin protection,etc.
10 3 Complete sets of legible plans. Must be drawn to scale,showing conformance to applicable local and state IS) ❑ ❑
building codes. Lateral design details and connections must be incorporated into the plans or on a separate full-size
sheet attached to the plans with cross references between plan location and details. Plan review cannot be completed if
copyright violations exist.
11 Site/plot plan drawn to scale. The plan must show lot and building setback dimensions;property corner elevations(if ® 0 ❑
there is more than a 4-ft.elevation differential,plan must show contour lines at 2-ft.intervals);location of easements
and driveway;footprint of structure(including decks);location of wells/septic systems;utility locations;direction
indicator;lot area;building coverage area;percentage of coverage;impervious area;existing structures on site;and
surface drainage.
12 Foundation plan. Show dimensions,anchor bolts,any hold-downs and reinforcing pads,connection details,vent size 0 ❑
El
and location.
13 Floor plans. Show all dimensions,room identification,window size,location of smoke detectors,water heater, ❑ ❑ 10
furnace,ventilation fans,plumbing fixtures,balconies and decks 30 inches above grade,etc.
14 Cross section(s)and details. Show all framing-member sizes and spacing such as floor beams,headers,joists,sub- 0 ❑ IN
floor,wall construction,roof construction. More than one cross section may be required to clearly portray
construction. Show details of all wall and roof sheathing,roofing,roof slope,ceiling height,siding material,footings
and foundation,stairs,fireplace construction,thermal insulation,etc.
15 Elevation views. Provide elevations for new construction;minimum of two elevations for additions and remodels. ❑ ❑ $i
Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope.
Full-size sheet addendums showing foundation elevations with cross references are acceptable.
16 Wall bracing(prescriptive path)and/or lateral analysis plans. Must indicate details and locations;for non- ❑ ❑ Ig
prescriptive path analysis provide specifications and calculations to engineering standards.
17 Floor/roof framing. Provide plans for all floors/roof assemblies,indicating member sizing,spacing,and bearing ❑ ❑ Igl
locations. Show attic ventilation.
18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered ❑ ❑ El
systems,see item 22,"Engineer's calculations."
19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists ❑ ❑ rz
over 10 feet long and/or any beam/joist carrying a non-uniform load.
20 Manufactured floor/roof truss design details. ® ❑ ❑
21 Energy Code compliance. Identify the prescriptive path or provide calculations. A gas-piping schematic is required ❑ ❑ El
for four or more appliances.
22 Engineer's calculations. When required or provided,(i.e.,shear wall,roof truss)shall be stamped by an engineer or ❑ ❑ El
architect licensed in Ore on and shall be shown to be applicable to the .ro'ect under review.
JURISDICTIONAL SPECIFICS
23 Three(3)site plans are required for Item 11 above. Site plans must be 8-1/2"x 11"or 11"x 17". ❑ ❑ tgl
24 Two(2)sets each are required for Items 16,19,20 and 22 above. ❑ ❑
25 Building plans shall not contain red lines or tape-ons. "Mirrored"building plans will not be accepted. ❑ ❑ E3
26 "Reversed"building plans must meet criteria outlined in the Permit&System Development Fees document. ❑ ❑
27 "Drawn to scale"indicates standard architect or engineer scale. ❑ ❑ EJ
28 Site plan to include tree size,type and location per approved project street tree plan(if applicable),and City of Tigard ❑ ❑ EJ
Street Tree List.
29 Site plan to include trees and tree protection measures as required by conditions of approval. Tree locations,driplines, ❑ ❑
and protection measures must be drawn to scale and must include the project arborist's signature of approval.
30 A Clean Water Services'Sensitive Area Pre-Screening Site Assessment form is required for all building additions, ❑ ❑
including decks,patio covers(over non-impervious surface)and accessory structures to existing residential dwellings
on a lot of record approved prior to September 9,1995.
I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(1 l/02/COM/WEB)
Electrical Permit Applicatio ECE ED FOR OFFICE I sI:ONI.1
City of Tigard APR 2 2 2022 Received
Date/B Permit#:
II
13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review
= Phone: 503.718.2439 Fax: 503.598.196�0 Y OF TIGARu DateB : Related Permit#:MJ�t 2._0
Inspection Line: 503.639.4175 y 1 (� A'(� n SI l Ready Date/By: Juris• ® See Page 2 for
TIGARD Internet: www.tigard-or.gov l�,l�t.L1IIV'-� #I�' G� Notified/Method: Supplemental Information
TYPE OF WORK PLAN REVIEW
❑New construction ®Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w'items checked):
0 Service or feeder 400 amps or more 0 Building over three stories.
❑ Demolition ®Other: Solar
where the available fault current 0 Marinas and boatyards.
CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings.
® I-and 2-family dwelling ❑Commercial/industrial 0 Accessory building less to ground,or exceeds 14,000 0 Commercial-use agricultural
amps for all other installations. buildings.
0 Multi-family 0 Master builder ❑Other: ❑Fire pump. ❑Installation of 150 KVA or
JOB SITE INFORMATION AND LOCATION 0 Emergency system. larger separately derived
❑Addition of new motor load of system.
Job#:Solar Job site address:16944 SW BirdsongSt.
100HP or more. ❑"A","E","1-2","1-3",
City/State/ZIP:Tigard, OR 97007 0 Six or more residential units. occupancy.
0 Health-care facilities. 0 Recreational vehicle parks.
Suite/bldg./apt.#: Project name:Solar for Nandi ❑Hazardous locations. 0 Supply voltage for more than
❑Service or feeder 600 amps or more. 600 volts nominal.
Cross street/directions to job site: FEE SCHEDULE
NE of the intersection of SW RoyRogers Rd and SW Appledale Rd. °eSfnpt1si I eryi l Earh I !' al I -
g pp New residential single-or multi-family dwelling unit.
Subdivision: Lot#: Includes attached garage.
1,000 sq.ft.or less 168.54 4
Tax map/parcel#:2 S 106DA 10400 Ea.add'►500 sq.ft.or portion 33.92 1
DESCRIPTION OF WORK Limited energy,residential
(with abovgye sq.ft.) 75.00 2
Installing 7.665kw solar pv system on roof of home. 21 REC 365TP Limrtedebove t.ft.-family
modules, 10 Chilicon CP720 microinverters and 1 CP250 micro.
residential(with above sq.ft.) 75.00 2
Renewable Energy ® See Page 2
® PROPERTY OWNER 0 TENANT Services or feeders installation,alteration,and/or relocation
Name:Amit Nandi 200 amps or less 100.70 2
Address:16944 SW Birdsong St. 201 amps to 400 amps 133.56 2
401 amps to 600 amps 200.34 2
City/State/ZIP:Tigard, OR 97007 601 amps to 1,000 amps 301.04 2
Phone:(971 )409-8316 Fax:( ) Over 1,000 amps or volts 552.26 2
Temporary services or feeders installation,alteration,and/or
Email:amit.nandi@gmail.com relocation
Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1
intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2
Owner signature: Date: 401 amps to 599 amps 168.54 2
® APPLICANT ® CONTACT PERSON Branch circuits—new,alteration,or extension,per panel
A.Fee for branch circuits with
Business name:National Solar above service or feeder fee, 7.42 2
each branch circuit
Contact name:Lynnette Harley B.Fee for branch circuits without
service or feeder fee,first Address:13521 174th St. Ct. E. branch circuit 56.18 2
City/State/ZIP:Puyallup, WA 98374 Each add'I branch circuit 7.42 2
Miscellaneous(service or feeder not included)
Phone:(253-)359-1444 Fax: :( ) Each manufactured or modular 67.84 2
dwelling,service and/or feeder
Email:Ldharley@comcast.net Reconnect only 67.84 2
CONTRACTOR Pump or irrigation circle 67.84 2
Business name:National Solar Sign or outline lighting 67.84 2
' Signal circuit(s)or limited-energy Address:2709 NW Crossing Drive panel,alteration,or extension. ❑ See Page 2 2
City/State/ZIP:Bend, OR 97703 Each additional inspection over allowable in any of the above
Additional inspection(1 hr min) 66.25/hr
Phone:(253)359-1444 Fax:(8774785-2582 Investigation(1 hr min) 90.00/hr
Industrial plant(1 hr min) 78.18/hr
Email:Ldharley@comeast.net Inspections for which no fee is
cat Lie.:186224 Electrical Lie.:C1512 Suprv.Lic.:6051 S specifically listed('iz hr min) 90.00/hr
ELECTRICAL PERMIT FEES
Suprv.Electrician signature,required: e.e. 02a Subtotal:
Print name: Cody Oram Date:4/22/2022 ❑Plan Review Required(25%of permit fee):
State surcharge(12%of permit fee):
Authorized signature: /4447-
TOTAL PERMIT FEE:
This permit application expires if a permit is not obtained within 180
Print name: Lynnette arley Date:4/22/2Q22 days after it has been accepted as complete.
* Number of inspections allowed per permit.
I:\Building\Pennits1ELC_PermitApp_ELR_ERE.doe Rev 06/17/2015 440-4615T(11/05/COM/WEB
Electrical Permit Application—City of Tigard
Page 2—Supplemental Information
Limited Energy Permit Fees: Renewable Energy Permit Fees:
RESIDENTIAL WORK ONLY: FEE SCHEDULE
Description I Qty. I Each Total
Fee for all residential systems combined: $75.00 Renewable electrical energy systems:
Check Type of Work Involved: 5 kva or less 100.70 2
5.01 to 15 kva 1 133.56 2
❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2
Wind generation systems in excess of 25 kva:
❑ Burglar Alarm 25.01 to 50 kva 301.04 2
50.01 to 100 kva 552.26 2
❑ Garage Door Opener* >100 kva(fee in accordance
552.26 2
with OAR 918-309-0040)
n Heating, Ventilation and Air Conditioning Solar generation systems in excess of 25 kva:
System* Each additional kva over 25 7.42 3
❑ Vacuum Systems* >100 kva—no additional charge 0.0 3
Each additional inspection over allowable in any of the above:
❑ Other: Each additional inspection is 66.25/hr 1
charged at an hourly(1 hr min)
Inspections for which no fee is 90.00/hr
specifically listed(Va hr min)
COMMERCIAL WORK ONLY: us
ELECtRICAL(Enter on Ir
Fee for each commercial system: S75.00 Subtotallowed tPage 1):
�' + Number of inspections allowed per permit.
(SEE OAR 918-309-0000)
Check Type of Work Involved:
❑ Audio and Stereo Systems
n Boiler Controls
❑ Clock Systems
❑ Data Telecommunication Installation
❑ Fire Alarm Installation
❑ HVAC
❑ Instrumentation
❑ Intercom and Paging Systems
n Landscape Irrigation Control*
❑ Medical
❑ Nurse Calls
❑ Outdoor Landscape Lighting*
❑ Protective Signaling
❑ Other:
Total number of commercial systems:
*No licenses are required. Licenses are required for all
other installations
I\Building\Permits\ELC_Perm0App_ELR_ERE.doc Rev 06/17/2015
r Y
•
°° Prescriptive Solar Photovoltaic Installation Checklist
::; 2019 Oregon Structural Specialty Code (OSSC) RECEIVED
ra' °- Compliance APR 2 2 2022
TIGARD
Use this checklist to demonstrate compliance with the prescriptive photovoltaic(PV) requireme } Wpm
31 1 1.3.5.3 and 311 1.3.4.8 of the Oregon Structural Specialty Code OSSC' . Separate electrical elrft�'hl' rp,�� E
1 y ( ) p
IE the installations.
PART I—PROPERTY OWNER INFORMATION
Property owner name: Amit Nandi Phone number:
Installation address:16944 Southwest Birdsong Street
C'it eaverton
Y=B State: Oregon 7.1P:97007
Structure on which modules arc to be installed:Roof of house
Installer: Q Contractor ❑ Owner(It-owner, skip to Part lll)
PART II—CONTRACTOR INFORMATION
Contractor name:National Solar Phone number:458-256-9019
Email address:colton@nationalsolarusa.com
13CD business license 1t: Contractor's CCI3tt:186224
PART III—STRUCTURAL CRITERIA
Roof structure requirements
Ij "No"is selected for any item below, or if the supporting structure is a manufactured dwelling, the project may not he
submitted using the prescriptive path.
Check the appropriate boxes for each item as it applies to the project.
• Structure is classified Risk Category 1 or 11 in accordance with OSSC 1604.5: Yes ❑ No
• Structure is of conventional light frame construction: Ycs
® ❑ No
• Supporting roof framing is one of the following: Yes
No
(check one) Q Pre-engineered trusses spaced<_24 inches o.c.;or
❑ Rafters spaced<24 inches o.c.and spans comply with OSSC 2308.7.2 or ORSC R802.5,respectively
• Ground snow load does not exceed maximum load: Yes ❑ No
(check one) 0 <50 psf for structures wider the ORSC,or ❑ 5 70 psf for structures under the OSSC
• The basic design wind speed does not exceed the following: ❑■ Yes ❑ No
(check one) ( <120 mph in Wind Exposure Category C for structures under the OSSC;or
❑ < 135 mph in Wind Exposure Category B for structures under the OSSC.or
❑ < 135 mph in Wind Exposure Category C for structures under the ORSC
• Roofing materials are metal,single-layer wood shingle or shake,or
not more than two layers of-composition shingle: ® Yes El No
• Module height is less than 18 inches from the top of the module to the roof surface and
complies with Figures 3111.3.5.3(1)and 3111.3.5.3(2): ® Yes ❑ No
BCD
Published by Building Codes Division—Aug. 18, 2021
oA.nnwn of c«wnor
M&oakum 1...uce'
PART III—STRUCTURAL CRITERIA (continued)
Loading requirements
Check the appropriate boxes for each item associated with the selected attachment method.
Attachment 1: PV modules or racking is attached directly to the roof framing or blocking:
• Combined weight of PV modules and racking is not more than 4.5 psf: O Yes ❑ No
• Spacing of PV modules or racking complies with one of the following: 0 Yes ❑ No
(check one) ❑ <48 inches in any direction;or
<24 inches in any direction where the following are true:
• Ground snow load is more than 36 psf
• Panels are located within 3 feet of a roof edge,hip,cave,or ridge
• Basic design wind speed is greater than 120 mph in Wind Exposure Category B
• Basic design wind speed is greater than 110 mph in Wind Exposure Category C
*If this is the appropriate attachment method and "No"is selected.for any of the items above. the project may not
be submitted using the prescriptive path.
❑ Attachment 2: PV modules or racking is attached directly to standing seam metal panels:
• Combined weight of PV modules and racking is not more than 4.5 psf: ❑ Yes ❑ No
• Clamps comply with the following requirements:
• Provide the following,allowable uplift capacity: ❑ Yes ❑ No
(cheek one) ❑ Not less than 115 pounds and spaced at 60 inches o.c.or less;or
❑ Not less than 75 pounds and spaced at 48 inches o.c.or less.
• Spacing between metal panel scams is not more than 24 inches ❑ Yes ❑ No
• Spacing along a metal panel scam is not more than 60 inches ❑ Yes ❑ No
• Metal rooting panels comply with the following requirements:
• Panel thickness is 26 gauge steel,minimum ❑ Yes ❑ No
• Panel width is 18 inches or less ❑ Yes ❑ No
• Attached with at least#10 screws at 24 inches o.c. ❑ Yes ❑ No
• installed over minimum 1/4-inch nominal wood structural panels attached to framing
with 8d nails at 6 inches o.e.at panel edges and 12 inches o.c.field nailing ❑ Yes ❑ No
*If this is the appropriate attachment method and "No"is selected for any of the items above, the project may not
he submitted using the prescriptive path.
PART IV—ROOF DESIGN SITE PLAN
Roof design requirements
• Attach a simple structural plan showing the roof framing(rafter size,type,and spacing)and PV system racking
attachment.
• System must be shown in sufficient detail to assess whether the requirements of Section 3111.3.5.3 have been met.
• The structural plan must be on 8.5-inch x 11-inch or larger paper.
PART V—PV MODULES
Manulacturer:REC
Model number: REC365TP4
Listing agency: UL
[2]