Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
I 2' LC \I 1 - OD `�1 --3'-2 3/4" TABLE 11 VI B SLJ PR.(.1'�1(, ii Wy OPENING WALL $ RE-ENFORCEMENT ,.�-1_O.„ SEE DETAIL 2 i © OO O i (J., ///z z ���/ //% COMPONENT SCHEDULE / „////////// _ r 1 ANTHEM CONSOLE -WALL MOUNT f �LIDING \\ NN —___�___-� TRAY \� _'•'E 2 ANTHEM 40KW GENERATOR CABINET \m UPPER _? O \� I o© Z ,f,W RAIL ,� 3 RT100/FTT 86" RADIOGRAPHIC TABLE . w I m / / v 1- ��__ 1 ;n 1- O / 1- ~ / ; :: \ 4 FLOOR TO WALL / CEILING TUBESTAND m j / .::• X-RAY ROOM / i �� % 5 VS300 WALL STAND i /, 1 T• .'.4 � t ' 6 DEL DR WORKSTATION WALL MOUNT (STANDARD QUAD / % —Lo i I':::::: `` 120 VAC RECEPTICAL REQUIRED) ):.:.:.:.:.: TABLE / j' '::;:I:..:; ;.:.i I i .I 7 X-RAY IN USE SIGN* (REQUIRES SEPARATE AC POWER) I'::::.:'::::........'.. `�� / 8 DOOR INTERLOCK SWITCH* / i:::::::. '::.'.'::..:.I 1. ! -� �--- ---� I 611110DETAIL)1 SEE FLOOR •••1'''_....... .I c �� / GENERATOR POWER RAIL / % • '•..;.;.••.:•_, N //� �__�"_''__; REQUIREMENTS: 9 CEILING MOUNTED WIRELESS ACCESS POINT (WAP) / ...... .. 3 `,A°.°.,: / THREE PHASEA ,/,/ •........'.'' .';':':';':''':':':' 1 . / 208VAC,100 AMP WALL J'� ::.:.1.._....... �i� 10 POWER OVER ETHERNET (FOR WAP) RE-ENFORCEMENT 1 p SERVICE SEE DETAIL 1 e / / / :.'.'.'.'.'.'.:.'.:.. 1 �2 —8"� SEE ' / 11 TWO NETWORK DROPS i ::. .•:: (ETAIL C )�p 3 � •'/ I 7 CIRCUIT N / BREAKER Al 12 DUAL 120V OUTLET FOR DR SYSTEM AND COMPONENTS 115 VAC , CONTROL / 7774)7.47r t *CONTRACTOR SUPPLIED /,,///,,l,A DETAILS: 3 / JUNCTION BOX 1. TUBESTAND BACKING -2 X 8 X 96 CLEAR PINE CENTERED AT 95"A.F.F. E 14"W X 48"H X 4"D ANCHOR TO WITHSTAND PULL OF 200 LBS. 3 FLUSH MOUNT 2. WALL STAND BACKING -2 X 8 X 24 CLEAR PINE CENTERED AT 83"A.F.F. / ANCHOR TO WITHSTAND PULL OF 150 LBS. / 3. OPERATION CONSOLE BACKING-24"WIDE PLYWOOD STARTING FROM / 20"A.F.F. UP TO THE BOTTOM OF THE OPERATION WINDOW. / ./ 4. DR WORKSTATION WALL BACKING 24"WIDE X 54" HIGH STARTING ABOUT 16"AFF. A \ ) \ / 5. PRINTED NOT TO SCALE. 6. FOR INSTALLATION PURPOSES REFER TO COMPONENT MANUALS. 1 AM E R I CAN FAMILY CARE 2/11 /2021 GRAPHIC SCALE REV INITIAL DATE ECN NO. CHANGE DESCRIPTION U 1' 2' 3' 4' MADE BY YP 2/11/2021 APPROVED BY DEL MEDICAL COMP. FILE NO. BLOOMINGDALE, ILLINOIS, (Te1)800.800.6006 sHT No1 CONT ON SHT- 3 DEL MEDICAL STANDARD FWFC THREE PHASE TERMINAL SCHEDULE EQUIPMENT SCHEDULE ITEM DESCRIPTION DIMENSIONS (INCHES) FACILITY TO DETERMINE SOURCE LOCATION. O U A NEMA1,208/240/480 VAC,THREE PHASE, FRONT OPERATED,CIRCUIT BREAKER ENCLOSURE WITH GROUND ENCLOSURE SHALL CONTAIN ONE NUMBER DESCRIPTION BTU/ HOUR WEIGHT U Q 100AMP FOR 208 VAC,80AMP FOR 240VAC,OR 50AMP FOR 480VAC,3 POLE THERMOMAGNETIC CIRCUIT BREAKER WITH SHUNT TRIP DEVICE. FLUSH MOUNT IN WALL WHERE SHOWN.LOCATE ENCLOSURE CENTER LINE 5'-6"A.F.F.NOTE:ELECTRICAL CONTRACTORS SHALL ENSURE W D H (LBS) < 0 THAT LUGS ARE LARGE ENOUGH TO FACILITATE OVERSIZED INCOMING CABLES REQUIRED BY X-RAY EQUIPMENT. cc 5 REFER TO"WIRING REQUIREMENTS". ANTHEM 40KW HF Z CD NEMA 1,208/120VAC SINGLE PHASE,4-WIRE,GENERAL PURPOSE,COMMERCIAL GRADE,LOADCENTER WITH NEUTRAL AND GROUND Al 1 GENERATOR OPERATOR 13.25 7.86 3.50 320 25 0 Z Al ACCESSORIES.ENCLOSURE SHALL CONTAIN THERMOMAGNETIC CIRCUIT BREAKERS WITH THE FOLLOWING RATINGS:ONE 30AMP,2-POLE CONSOLE 0 0 MAIN;ONE 15AMP, 1 POLE,CB FOR THE TABLE;ONE 15AMP, 1-POLE,CB SPARE;LOCATE ENCLOSURE CENTER LINE 5'-6"A.F.F. ANTHEM 40KW HF Q UJ Q B 4"X 2"X 2"DEEP SWITCH BOX. FLUSH MOUNT IN WALL WHERE SHOWN.LOCATE BOX CENTER LINE AT 6'-0"A.F.F. ELECTRICAL CONTRACTOR SHALL PROVIDE ONE NORMALLY OPEN SWITCH WITH RED MUSHROOM HEAD AND AN"EMERGENCY OFF"NAME 2 GENERATOR POWER 27.20 17.60 45.75 4000 300 Q J PLATE.SWITCH WILL BE USED FOR SHUNT TRIP DEVICE LOCATED ON CIRCUIT BREAKER(ITEM A). CABINET CL --4.. 6"X 6"X 4"DEEP JUNCTION BOX.FLUSH MOUNT AT OR SURFACE MOUNT WALL WHERE SHOWN.LOCATE BOX CENTER LINE 36"A.F.F. CELECTRICIAN IS TO SUPPLY OVERSIZED COVER PLATE.COVER PLATE SHALL COSMETICALLY BLEND WITH PAINTED WALL. 3 RT100 4-WAY FLOAT TABLE 86.62 32.00 33.00 410 468 H Z CABLE ACCESS FOR THE WALL STAND. 6"X 6"X 4"DEEP JUNCTION BOX.FLUSH MOUNT IN WALL WHERE SHOWN.LOCATE BOX CENTER LINE 12"A.F.F. 4 FLOOR TO WALL/CEILING - D ELECTRICIAN IS TO SUPPLY OVERSIZED COVER PLATE.COVER PLATE SHALL COSMETICALLY BLEND WITH PAINTED WALL. MOUNTED TUBESTAND 96.00 43.00 94-124 1200 373 d W CABLE ACCESS FOR THE CONTROL CONSOLE. O H 14"WIDE X 48"HIGH X 4"DEEP JUNCTION BOX.FLUSH MOUNT IN WALL WHERE SHOWN.LOCATE BOTTOM OF E BOX AT 12 INCHES A.F.F. 5 VS300 } E ELECTRICIAN IS TO SUPPLY OVERSIZED COVER PLATE.COVER PLATE SHALL COSMETICALLY BLEND WITH PAINTED WALL. WALLSTAND 25.00 12.25 84.00 35 200 d PROVIDE CABLE ACCESS FOR THE POWER CABINET. 4"X 4"X 4"DEEP JUNCTION BOX.LOCATED ABOVE FINISHED CEILING APPROXIMATELY WHERE SHOWN. 6 DELWORKS DR SYSTEM < Q F ELECTRICIAN TO PROVIDE COVER PLATE. TYPICAL PC W CABLE ACCESS FOR THE WAP. WORKSTATION PC I X 6"X 6"X 4"DEEP JUNCTION BOX.FLUSH MOUNT IN FLOOR WHERE SHOWN. PROVIDE A BLANK LIQUID TIGHT COVER PLATE. -OR- I-7 "X RAY IN USE" SIGN CONTRACTOR SUPPLIED SEE PAGE 3 Lt_ IF THE SLAB ALREADY EXISTS,SURFACE MOUNT WIRE MOLD IS PERMISSIBLE.FINAL LOCATION TO BE DETERMINED AT TIME OF TABLE 0 Z G INSTALL.WIREMOLD TO BE PROVIDED AND INSTALLED BY SITE ELECTRICIAN.CONSULT WITH THE PROJECT MANAGER FOR ACTUAL REQUIREMENTS.CABLE ACCESS FOR THE TABLE. 8 DOOR INTERLOCK SWITCH CONTRACTOR SUPPLIED SEE PAGE 3 H 0 PROVIDE ONE 1-POLE,SINGLE THROW,MOMENTARY,EXPOSURE INTERLOCK SWITCH IN DOOR FRAME. CEILING MOUNTED J N THE FOLLOWING DOOR INTERLOCK SWITCH IS REQUIRED FOR ALL INSTALLATIONS: 9 8.00 ROUND 2.00 N/A 1.5 m O GRAINGER DYNAVOX MODEL 2EXV1 WIRELESS ACCESS POINT d 4"X 4"X 2"JUNCTION BOX FOR THE"X-RAY IN USE"WARNING SIGN. FLUSH MOUNT fN WALL OR CEILING.EXACT LOCATION TO BE POWER OVER ETHERNET Z W W DETERMINED BY THE FACILITY.THE X-RAY ON WARNING LAMP CIRCUIT SHALL BE BE COORDINATED BETWEEN THE FACILITY,THE 10 (POE) 2.00 2.00 4.00 N/A N/A 0 O a.. W CONSTRUCTION PARTICIPANTS AND EQUIPMENT INSTALLERS.REFER TO ELECTRIC BLOCK DIAGRAM.SOURCE ON AMAZON W WIRING REQUIREMENTS SINGLE PHASE W CO SO URCE OURCE POWER SOAC MAIN INCOMING ELECTRICAL W 0_ GENERATOR DIST. XFMR MINIMUM COPPER WIRE SIZE MIN. SWITCH MAX. APPARENT fx A POWER SOURCE MODEL/ DISTANCE ORIN FEET F FUSE, OR MOMENTARY MAINS BLOCK I- d INCOMING DEDICATED DISTRIBUTION POINT RTOO M DISCONNECT BEAKER CURRENT RESISTANCE U) W LINE ENERGY TO GENERATOR RATING DRAW /Al W __ DIAGRAM DISCONNECT PANEL W = VOLTAGE SOURCE GROUND (15' MAX) VARIES (..) 1-- 50' 100' 200' / QO cC (15 M) (30 M) (60 M) 1-1/2" W 40kW, 600 mA #1 #0 #00 #6 #6 -- 1/2" 0. W 208VAC 65 kVA 50mm2 50mm2 95mm2 16mm2 16mm2 100 A 161 A 0.1 0 0O <CL 3 PHASE ® VARIES 1/2" 0 J 40kW, 600 mA W < 240VAC 65 kVA #2 #0 #0 #6 z #6 z #6 80 A 142 A 0.12 f2 ellnn �� C] U 3 PHASE 50mm250mm295mm216mm 16mm O A l� B 40kW, 600 mA #4 #1 #0 #6 .____../ C] 2 480VAC 65 kVA 50 A 72 A 0.13 0 NOTE:THIS BLOCK DIAGRAM IS NOT INTENDED < _I3 PHASE 25mm2 50mm2 50mm2 16mm2 16mm2 1/2" TO INDICATE THE EXACT CONNECTION POINTS U W 2" ON THE TROUGH.THE ELECTRICAL E p WIRING INFORMATION \ CONTRACTOR SHALL DETERMINE THE I- >- WIRE SIZE TO BE DETERMINED BY INCOMING WIRE SIZE. EC TO CONNECT AT"A"AND LEAVE 6'-0"TAIL AT"E". 2" -- SHORTEST CONDUIT RUNS THAT SITE 0 CO "A"TO "E" 1" I CONDITIONS ALLOW AND MAKE APPROPRIATE W 0 _ MAXIMUM WIRE SIZE#6 COPPER. / \ CONNECTIONS WHERE POSSIBLE. I j W 2-#14 AWG PLUS GROUND, EC SHALL CONNECT TO 15 AMP 1 P, CB IN (A1)(TABLE)AND LEAVE 10'-0"TALES AT"G". F D UNDER THE SLAB TROUGH IS PREFERABLE.IF gillp < A1"TO "E" IDENTIFY CB AND WIRES AS TABLE POWER. THE SLAB ALREADY EXISTS,SURFACE MOUNT / CIWIRE MOLD IS ACCEPTABLE.CONSULT WITH Z W "C"TO"E" LEAVE PULL STRINGS (MAXIMUM CONDUIT LENGTH IS 35'-0") THE PROJECT MANAGER FOR ACTUAL < OL REQUIREMENTS. Z U "D"TO "E" _ LEAVE PULL STRINGS (MAXIMUM CONDUIT LENGTHS IS 35'-0") 0 H "G"TO "E" LEAVE PULL STRINGS (MAXIMUM CONDUIT LENGTHS IS 35'-0") ARCHITECTURAL NOTES 0 Q "B"TO "A,. 2-#14 AWG PLUS GROUND. EC SHALL CONNECT TO (A)AND (B). PROVIDE POWER IF NECESSARY FOR SHUNT D c - _ "D" TO"F" TRIP SOLENOID. DEL MEDICAL'S DRAWINGS ARE INTENDED TO PROVIDE THE CONSTRUCTION PARTICIPANTS WITH CC 0 LEAVE PULL STRINGS. SPECIFICATION AND CONCEPTUAL INFORMATION ONLY. THE ARCHITECT OF CHOICE OR PROJECT 2-#14 AWG PLUS GROUND. EC TO CONNECT"X-RAY IN USE"WARNING LIGHT CIRCUIT PER EQUIPMENT MANAGER SHALL ENSURE THAT ALL CONSTRUCTION COMPLIES WITH BUILIDING CODES AND Z I REGULATIONS THAT HAVE JURISDICTION. THOSE MAKING USE OF OR RELYING ON THIS MATERIAL O I- "W"TO"E" SUPPLIER RECOMMENDATIONS AND LEAVE 10'-0"TAILS IN (E). EC SHALL IDENTIFY WIRES AS "X-RAY WARNING ASSUME ALL RISKS AND LIABILITY ARISING FROM SUCH USE OR RELIANCE. 0 SIGN""L", "N", "G". "N"TO"E" 2-#14 AWG PLUS GROUND IF REQUIRED. EC SHALL CONNECT TO (N)AND LEAVE 10'-0"TAILS AT(E). IDENTIFY WIRES AS DOOR INTERLOCK SWITCH.