Loading...
Plans urFR, 'C VALIDITY OF PERMIT verizonv R�� �`�� JURISDICTIONAL APPROVAL: THE ISSUANCE OF A PERMIT ' I �/ BASED ON CONSTRUCTION AUK 2021 DOCUMENTS AND OTHER DATA SHALL NOT PREVENTCITY TIGARD THE CODE OFFICIAL FROM BUILDING DIVISION CITYOF TIGARD approved by Planning VE• ".►• iel ;�a NUMBER: 307842 BUSINESS UNIT #: 874135 Sete: gl5( 4 Z VERIZON SITE NAME: VILLA RIDGE - A SITE ADDRESS:' ,4,I 1 T GA AVE D,6o�2 hitlals: A- _ _. SITE TYPE: MONOPOLE COUNTY: WASHINGTON , TOWER HEIGHT: 94'-0" JURISDICTION: CITY OF TIGARD, OR verizon VERIZON NG152769 3245158TH AVENUE MS231 • BELLEVUE,WA 98008 SITE INFORMATION DRAWING INDEX APPROVALS LOCATION MAP CROWN CROWN CASTLE USA INC. WEST PORTLAND SHEET# SHEET DESCRIPTION VERIZON SIGNATURE BLOCKs"It CASTLE 4,,,,,,Hunter Swoon �4'�gal�u{a cQmm"sane,t, , 1505 WESTLAKE AVENUE NORTH,SUITE 801 SITE NAME: \eexoeal- SIGNATURE DATE �y SITE ADDRESS: 10955 SW 65TH AVE Ti- TITLE SHEET . ` SEATTLE,WA 98109 SITTIGARD,OR 97223 T-2 GENERAL NOTES ACQUISITION -,_ N.,: c.r< 6 Ors Pub&Eatery Y r 1 PaC{` ,,. �� I COUNTY: WASHINGTON C-1.1 OVERALL SITE PLAN CONSTRUCTION g ne t,°,,t n g.'4 rya AB MAP/PARCEL#: R2144057 C-1.2 SITE PLAN AREA OF CONSTRUCTION: EXISTING RADIO 1""' - i.' ' 49030 Pontiac Trail.Suite 400 LATITUDE: 45°26'29.40" C-2 EXISTING&NEW ELEVATION te'd R Wixom,Michigan 48393 MICROWAVE C-3 ANTENNA PLANS&CABLE SCHEDULE �Mcn`'." °°°�0 t1 0 �5 , PHONE:(248)705-9212 LONGITUDE: 122°44'38.30" �mnc n wr,t,n -- LAT/LONG TYPE: NAD83 C 4 EQUIPMENT SPECS TELCO r GROUND ELEVATION: 344 FT C-5 REDS EQUIPMENT - - VERIZON SITE NUMBER:307842 CURRENT ZONING: CITY OF TIGARD,OR C-6 CONFIGURATION DIAGRAM PROJECT ADMINISTRATOR JURISDICTION: CITY OF TIGARD,OR BU#:874135 OCCUPANCY CLASSIFICATION: U G-1 GROUNDING DETAILS t TYPE OF CONSTRUCTION: LIB G-2 GROUNDING DETAILS xo ADMINISTRATOR .o 0-.0-co "' 1-6;'f 10955 SW 65TH AVE WEST PORTLAND A.D.A.COMPLIANCE: FACILITY IS UNMANNED AND NOT FOR CROWN CASTLE USA INC.SIGNATURE BLOCK ' HUMAN HABITATION z. 4,qv TIGARD,OR 97223 PROPERTY OWNER: PORTLAND GENERAL ELECTRIC COMPANY(1) APPROVALSIGN r,,i, DATEit. y° EXISTING 94'-0"MONOPOLE LLLL o? CITY,STATE ZIP SITE ACQUISITION cK, ,ae Veterinary{ , TOWER OWNER: CROWN CASTLE USA INC. PLANNER NO SCALE 2000 CORPORATE DRIVE \LL DRAWINGS CONTAINED HEREIN ARE FORMATTED FOR ISSUED FOR: _CANONSBURG,PA 15317 _ __ 11X17.CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING CONSTRUCTION DRIVING DIRECTIONS FROM SOUTHWESTVERIZON LOCAL OFFICE(3245 158TH AVENUE MS 231,BET T.FVUE,WA _ `, DATE DAWN DESCRIPTION nEs./c 98008):DEPART AND HEAD ON 158TH AVE SE 138 FT,BEAR RIGHT ONTO SE EASTGATE DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL A 04/26/2021 RC PRELIMINARY PL CAI;RIER/APPLICANT: P,I:VEZON WIRELESS IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY PROJECT MANAGER WAY 0.1 MI,TAKE THE RAMP ON THE LEFT FOR 1-90 WEST AND HEAD TOWARD SEATTLE 1.4 MI, 1 3245 1�8Tif AVENUE MS 231- TAKE THE RAMP ON THE RIGHT FOR I-405 S 11.2 MI,TAKE THE RAMP FOR I-5 S 169.4 MI,AT EXIT 294, 0 07/15/2021 RC FINAL PL DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR UTILITY MANAGER HEAD RIGHT ON THE RAMP FOR OR-99W TOWARD NEWBERG/TIGARD 0.4 MI,KEEP STRAIGHT TO BELLEVUE,WA 98008 BE RESPONSIBLE FOR SAME. GET ONTO OR-99W/SW PACIFIC HWY 354 FT,TURN LEFT ONTO SW CORONADO ST 0.1 MI,ROAD ELECTR1 PROVIDER: CITY OP TIGARDf. • LANDLORD NAME CHANGES TO SW 64TH AVE 443 FT,TURN RIGHT 161 FT,ARRIVE AT 10955 SW 65TH AVE, TELCO Px IEWED FOR CODE COMPLIANCE PROJECT DESCRIPTION TIGARD,OR 97223 • Approvedt ? THE PURPOSE OF THIS PROJECT IS TO ENHANCE. OTC: a c BROADBAND CONNECTIVITY AND CAPACITY TO THE d ENHANCE- OTC: 3. (� EXISTING ELIGIBLE WIRELESS FACILITY. APPLICABLE CODES/REFERENCE � D`40, Perm*#t'.Jet I )- la C�c� `,1 -I'OWASCOPEOFWORK: DOCUMENTS �� y ,� •REMOVE(6)ANTENNAS �l Pe Address: :J 1 ' i gs�+ AV/ _•REMOVE(6)RRHS ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH I1CH0�� 1 1 v i INSTALL(5)ANTENNAS THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL H •SIDE BY SIDE ANTENNA MOUNT(COMMSCOPE GOVERNING AUTHORITIES.NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT ��M y +�+ P/N:BSAMNT-SBS-1-2) WORK NOT CONFORMING TO THESE CODES: •WEFT a+O/ D>,• P 1 ii •INSTALL(3)RRHs CODE TYPE CODE mi , •INSTALL(1)OVP BUILDING 2019 OR STRUCTURAL SPECIALTY CODE(OSSC) \&E FIRM:-. __ PET LICHOMSKI,AIA •INSTALL(1)HYBRID CABLE MECHANICAL 2019 OR MECHANICAL SPECIALTY CODE(OMSC) 6775 75 •INSTALL CONTRACTOR PMI REQUIREMENTS 49030 PONTIAC I RAIL.SUIE.400 (3)VZWSMART-MSK8 UNIVERSAL ANGLE Q ELECTRICAL 2021 OR ELECTRICAL SPECIALTY CODE(OESC) ,WIXOM,MI 48393 CORNER CONNECTION BRACKET OF O • N PH:(248)705-9212 •INSTALL(3)VZWSMART-PLK8 SUPPORT BRACING KIT PMI ACCESSED AT https://pmi.vxwsmartcom REFERENCE DOCUMENTS: •INSTALL(1)VZWSMART-MSK10 WIRE ROPE ROUTING CROWN CASTLE SMART TOOL VENDOR STRUCTURAL ANALYSIS: BY OTHERS BRACKET USA INC.DISTRICT PROJECT NUMBER DATED: CONTACTS: GROUND SCOPE OF WORK: VZW LOCATION CODEMOUNT ANALYSIS: TOWER ENGINEERING SOLUTIONS,LLC JESSICA DORMS-PROJECT MANAGER ---- •INSTALL(1)OW (PSLC) DATED: 06/25/2021 STEVE HANDY-CONSTRUCTION MANAGER REDS REVISION: ---- *** PMI AND REQUIREMENTS ALSO EMBEDDED IN MOUNT DATED: ---- ANALYSIS REPORT ORDER ID: 540658 IT 1,\VIOLATION OF LAW FOR ANY PERSON REVISION: 4 :N,ITS 11-IEY ARE ACTING UNDER THE DIRECTION 1)P A LICENSED PROFESSIONAL ENGINEER, MOUNT MODIFICATION REQUIRED Y TO ALTER THIS DOCUMENT. `- NOTE' VzW APPROVED SMART KIT VENDORS CALL OREGON ONE CAIL. 8'3 SHEET NUMBER: " REVISION: PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST ( (800)332-2344 ' T 0 CONTACT THE CROWN NOC AT(800)788-7011&CROWN c.Ar 1 3 WORKING DAYS �, REFER TO MOUNT MODIFICATION DRAWINGS PAGE FOR _ 1VAX'CONSTRUCTION MANAGER 'SMART KIT APPROVED VENDORSaEFOREYou DIG! Il 0 • I \• r re- CROWN CASTLE USA INC. SITE ACTIVITY REQUIREMENTS: GENERAL NOTES: ELECTRICAL INSTALLATION NOTES: JURISDICTIONAL APPROVAL: 1. NOTICE TO PROCEED- NO WORK SHALL COMMENCE PRIOR TO CROWN CASTLE USA INC. WRITTEN NOTICE 1. FOR THE PURPOSE OF CONSTRUCTION DRAWING, THE FOLLOWING DEFINITIONS SHALL APPLY: CONTRACTOR: GENERAL CONTRACTOR RESPONSIBLE FOR CONSTRUCTION 1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS, NEC AND ALL APPLICABLE TO PROCEED (NIP) AND THE ISSUANCE OF A PURCHASE ORDER. PRIOR TO ACCESSING/ENTERING THE CARRIER: VERIZON FEDERAL, STATE, AND LOCAL CODES/ORDINANCES. SITE YOU MUST CONTACT THE CROWN CASTLE USA INC. NOC AT 800-788-7011 & THE CROWN CASTLE TOWER OWNER: CROWN CASTLE USA INC. 2. CONDUIT ROUTINGS ARE SCHEMATIC. CONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO EQUIPMENT IS NOT BLOCKED USA INC. CONSTRUCTION MANAGER. 2. THESE DRAWINGS HAVE BEEN PREPARED USING STANDARDS OF PROFESSIONAL CARE AND COMPLETENESS NORMALLY AND TRIP HAZARDS ARE ELIMINATED. 2. "LOOK UP' - CROWN CASTLE USA INC. SAFETY CUMB REQUIREMENT: EXERCISED UNDER SIMILAR CIRCUMSTANCES BY REPUTABLE ENGINEERS IN THIS OR SIMILAR LOCALITIES. IT IS 3. WIRING. RACEWAY AND SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEC. THE INTEGRITY OF THE SAFETY CLIMB AND ALL COMPONENTS OF THE COMBING FACILITY SHALL BE ASSUMED THAT THE WORK DEPICTED WILL BE PERFORMED BY AN EXPERIENCED CONTRACTOR AND/OR WORKPEOPLE 4. ALL CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MINIMUM CABLE SEPARATION AS REQUIRED BY THE NEC. CONSIDERED DURING ALL STAGES OF DESIGN, INSTALLATION, AND INSPECTION. TOWER MODIFICATION, MOUNT WHO HAVE A WORKING KNOWLEDGE OF THE APPLICABLE CODE STANDARDS AND REQUIREMENTS AND OF INDUSTRY 4.1. ALL EQUIPMENT SHALL BEAR THE UNDERWRITERS LABORATORIES LABEL OF APPROVAL AND SHALL CONFORM TO REINFORCEMENTS, AND/OR EQUIPMENT INSTALLATIONS SHALL NOT COMPROMISE THE INTEGRITY OR ACCEPTED STANDARD GOOD PRACTICE. AS NOT EVERY CONDITION OR ELEMENT IS (OR CAN BE) EXPLICITLY SHOWN REQUIREMENT OF THE NATIONAL ELECTRICAL CODE. FUNCTIONAL USE OF THE SAFETY CUMB OR ANY COMPONENTS OF THE CLIMBING FACIUTY ON THE ON THESE DRAWINGS, THE CONTRACTOR SHALL USE INDUSTRY ACCEPTED STANDARD GOOD PRACTICE FOR 4.2. ALL OVERCURRENT DEVICES SHALL HAVE AN INTERRUPTING CURRENT RATING THAT SHALL BE GREATER THAN THE SHORT STRUCTURE. THIS SHALL INCLUDE, BUT NOT BE UNITED TO: PINCHING OF THE WIRE ROPE, BENDING OF MISCELLANEOUS WORK NOT EXPUCITLY SHOWN. CIRCUIT CURRENT TO WHICH THEY ARE SUBJECTED, 22,000 AIC MINIMUM. VERYIFY AVAILABLE SHORT CIRCUIT CURRENT DOES THE WIRE ROPE FROM ITS SUPPORTS, DIRECT CONTACT OR CLOSE PROXIMITY TO THE WIRE ROPE WHICH 3. THESE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE MEANS OR METHODS OF NOT EXCEED THE RATING OF ELECTRICAL EQUIPMENT IN ACCORDANCE WITH ARTICLE 110.24 NEC OR THE MOST CURRENT MAY CAUSE FRICTIONAL WEAR, IMPACT TO THE ANCHORAGE POINTS IN ANY WAY, OR TO IMPEDE/BLOCK ITS CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE CONSTRUCTION MEANS, METHODS, ADOPTED CODE PRE THE GOVERNING JURISDICTION. INTENDED USE. ANY COMPROMISED SAFETY CUMB, INCLUDING EXISTING CONDITIONS MUST BE TAGGED OUT TECHNIQUES, SEQUENCES. AND PROCEDURES. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY FOR 5. EACH END OF EVERY POWER PHASE CONDUCTOR, GROUNDING CONDUCTOR, AND TELCO CONDUCTOR OR CABLE SHALL BE AND REPORTED TO YOUR CROWN CASTLE USA INC. POC OR CALL THE NOC TO GENERATE A SAFETY CUMB PROTECTION OF LIFE AND PROPERTY DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE UNITED LABELED WITH COLOR-CODED INSULATION OR ELECTRICAL TAPE (3M BRAND, 1/2" PLASTIC ELECTRICAL TAPE WITH W TO, BRACING, FORMWORK, SHORING, ETC. SITE VISITS BY THE ENGINEER OR HIS REPRESENTATIVE WILL NOT INCLUDE PROTECTION, OR EQUAL). THE IDENTIFICATION METHOD SHALL CONFORM WITH NEC AND OSHA. _ MAINTENANCE AND CONTRACTOR NOTICE TICKET. ) 3. PRIOR TO THE START OF CONSTRUCTION, ALL REQUIRED JURISDICTIONAL PERMITS SHALL BE OBTAINED. INSPECTION OF SSE ITEMS AND ISR FORO STRUCTURALAWIN H OBSERVATION THE FINISHED GENERAL E NONLY. 6. CO IGELECTRICAL N, WIRE CONFIGURATION, SHALL BE CLEARLY LABELED T DID TAGS SHOWING ID U RATED AN, PHASE THIS INCLUDES, BUT IS NOT LIMITED TO, BUILDING, ELECTRICAL, MECHANICAL, FIRE, FLOOD ZONE, 4. NOTES ANDDETAILS IN THE CONSTRUCTION N SHALL TAKE PRECEDENCERMTOOVERM GENERAL NOTES AND TYPICAL CONFIGURATION, WIRE CONFIGURATION, POWER OR AMPACfTY RATING AND BRANCH CIRCUIT ID NUMBERS(i.e. PANEL BOARD AND DETAILS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT, ENVIRONMENTAL AND ZONING. AFTER ONSITE ACTIVITIES AND CONSTRUCTION ARE COMPLETED, ALL CIRCUIT ID'S). AND/OR AS PROVIDED FOR IN THE CONTRACT DOCUMENTS. WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, REQUIRED PERMITS SHALL BE SATISFIED AND CLOSED OUT ACCORDING TO LOCAL JURISDICTIONAL 8. PANEL BOARDSWRA D NUMBERS) SHALL CLEARLY EDECU WITHGPLASTIC O MO GENERAL NOTES, ED SPECIFICATIONS, THE GREATER, MORE STRICT REQUIREMENTS, SHALL GOVERN. IF FURTHER REQUIREMENTS. 8. ALL TIE WRAPS SHALL BE CUT FLUSH WITH APPROVED HOLING TOOL TO REMOVE SHARP EDGES. 4. ALL CONSTRUCTION MEANS AND METHODS; INCLUDING BUT NOT LIMITED TO, ERECTION PLANS, RIGGING CLARIFICATION ISF RTREQUIREDHASNTMAD THE ENGINEERROVI OF RECORD. 9. ALL POWER AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE SINGLE COPPER CONDUCTOR (#14 OR LARGER) • 5. SUBSTANTIAL EFFORT HAS BEEN MADE TO PROVIDE ACCURATE DIMENSIONS AND MEASUREMENTS ON THE DRAWINGS TO PLANS, COMBING PLANS, AND RESCUE PLANS SHALL BE THE RESPONSIBILITY OF THE GENERAL WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. ASSIST IN THE FABRICATION AND/OR PLACEMENT OF CONSTRUCTION ELEMENTS BUT IT IS THE SOLE RESPONSIBILITY CONTRACTOR RESPONSIBLE FOR THE EXECUTION OF THE WORK CONTAINED HEREIN, AND SHALL MEET 10. SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED INDOORS SHALL BE SINGLE COPPER CONDUCTOR(#6 OR LARGER) WITH 1 ANSI/ABBE A1O.48 (LATEST EDITION); FEDERAL, STATE, AND LOCAL REGULATIONS; AND ANY APPLICABLE OF THE CONTRACTOR TO FIELD VERIFY THE DIMENSIONS, MEASUREMENTS, AND/OR CLEARANCES SHOWN IN THE TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. INDUSTRY CONSENSUS STANDARDS RELATED TO THE CONSTRUCTION ACTIVITIES BEING PERFORMED. ALL CONSTRUCTION DRAWINGS PRIOR TO FABRICATION OR CUTTING OF ANY NEW OR EXISTING CONSTRUCTION ELEMENTS. 11. POWER AND CONTROL WIRING IN FLEXIBLE CORD SHALL BE MULTI-CONDUCTOR. TYPE SOOW CORD (#14 OR LARGER) UNLESS RIGGING PLANS SHALL ADHERE TO ANSI/ASSE A10.48 (LATEST EDITION) AND CROWN CASTLE USA INC. IF IT ISFRMICST THERE ARE DISCREPANCIES AND/OR CONFLICTS WITH THE CONSTRUCTION DRAWINGS THE OTHERWISE SPECIFIED. verizon ENGINEER OF RECORD IS TO BE NOTIFIED AS SOON AS POSSIBLE. STANDARD CED-STD-10253, INCLUDING THE REQUIRED INVOLVEMENT OF A QUALIFIED ENGINEER FOR12. POWER AND CONTROL WIRING FOR USE IN CABLE TRAY SHALL BE MULTI-CONDUCTOR, TYPE TC CABLE(#14 OR LARGER), WITH CLASS IV CONSTRUCTION, TO CERTIFY THE SUPPORTING STRUCTURE(S) IN ACCORDANCE WITH ANSI/TIA-322 6. PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING CAN CONTRACTOR SHALL VISIT THE CELL SITEN TON FAMILIARIZE WITUCH THE TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. (LATEST EDITION). EXISTING CONDITIONS AND TO CONFIRM THAT THE WORK CAN BE ACCOMPLISHED AS SHOWN ON THE CONSTRUCTION 13. ALL POWER AND GROUNDING CONNECTIONS SHALL BE CRIMP-STYLE, COMPRESSION WIRE LUGS AND WIRE NUTS BY THOMAS AND 3245 158TH AVENUE MS 231 DRAWINGS. ANY DISCREPANCY FOUND SHALL BE BROUGHT TO THE ATTENTION OF CROWN CASTLE. BE7T5 (OR EQUAL). LUGS AND WIRE NUTS SHALL BE RATED FOR OPERATION NOT LESS THAN 75' C (90' C IF AVAILABLE). BELLEVUE,WA 98008 5. ALL SITE WORK TO COMPLY WITH OAS-STD-10068 "INSTALLATION STANDARDS FOR CONSTRUCTION 7. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, 14. RACEWAY AND CABLE TRAY SHALL BE USTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL ANSI/IEEE ACTIVITIES ON CROWN CASTLE USA INC. TOWER SITE," CED-STD-10294 "STANDARD FOR INSTALLATION OF REGULATIONS AND ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, MOUNTS AND APPURTENANCES,"AND LATEST VERSION OF ANSI/T1A-1019-A-2012 "STANDARD FOR ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE AND NEC. CROWN INSTALLATION, ALTERATION, AND MAINTENANCE OF ANTENNA SUPPORTING STRUCTURES AND ANTENNAS." OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPUCABLE MUNICIPAL AND UTILITY COMPANY 15. ELECTRICAL METALLIC TUBING (EMT), INTERMEDIATE METAL CONDUIT (INC), OR RIGID METAL CONDUIT(RMC) SHALL BE USED FOR 6. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SPECIFICATIONSSNOTE ANDH LOCAL THE EISDICTIONAL CODES. ORDINANCESFUIS AND APPLICABLE REGULATIONS.IPMEN EXPOSED INDOOR LOCATIONS. 0:40: CASTLE SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY CROWN CASTLE USA INC. PRIOR TO 8. L BARS ECESS RYHERWISE, LET WORK SHALL TIONSDA FINDICTED MATERIALS, WIN SMELT, APPURTENANCES AND 17. SLECTRILE METAUC TUBINR (EMT) N TEA GUTS AD CABLE (ULE 80AP BE USED FER CONCEALED DALINDOLR LPROVED PROCEEDING WITH ANY SUCH CHANGE OF INSTALLATION. LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 17. SCHEDULE 40 PVC UNDERGROUND ON STRAIGHTS AND SCHEDULE 80 PVC FOR ALL ELBOWS/90s AND ALL APPROVED ABOVE 7. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE 9. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S GRADE PVC CONDUIT. 1505 WESTLAKE AVENUE NORTH,SUITE 801 METALLICCODES, REGULATIONS AND ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 18. LIQUID-TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID-TITS FLEX) SHALL BE USED INDOORS AND OUTDOORS, WHERE VIBRATION SEA"I"1'LE,WA 98109 10. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL OCCURS OR FLEXIBILITY IS NEEDED. COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBUC PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THE CARRIER AND CROWN CASTLE PRIOR TO PROCEEDING 19. CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION-TYPE AND APPROVED FOR THE LOCATION USED. SET AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH WITH ANY SUCH CHANGE OF INSTALLATION. SCREW FITTINGS ARE NOT ACCEPTABLE. ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, 11. CONTRACTOR IS TO PERFORM A SITE INVESTIGATION AND IS TO DETERMINE THE BEST ROUTING OF ALL CONDUITS FOR 20. CABINETS, BOXES AND WIRE WAYS SHALL BE LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL,ANSI/IEEE ANDLAB ORDINANCES AND APPLICABLE REGULATIONS. POWER, AND TELCO AND FOR GROUNDING CABLES AS SHOWN IN THE POWER. TELCO, AND GROUNDING PLAN THE NEC. 8. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S DRAWINGS. 21. WIREWAYS SHALL BE METAL WITH AN ENAMEL FINISH AND INCLUDE A HINGED COVER, DESIGNED TO SWING OPEN DOWNWARDS RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 12. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY (WIREMOLD SPECMATE WIREWAY). 49030 Pontiac Trail,Suite 400 9. THE CONTRACTOR SHALL CONTACT UTIUTY LOCATING SERVICES PRIOR TO THE START OF CONSTRUCTION. DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF CROWN CASTLE USA INC. 22. SLOTTED WIRING DUCT SHALL BE PVC AND INCLUDE COVER (PANDUIT TYPE E OR EQUAL). Wixom,Michigan 48393 10. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES WHERE ENCOUNTERED IN THE 13. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND 23. CONDUITS SHALL BE FASTENED SECURELY IN PLACE WITH APPROVED NON-PERFORATED STRAPS AND HANGERS. EXPLOSIVE ♦ PHONE:(248)705-9212 WORK, SHALL BE PROTECTED AT ALL TIMES AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE OTHER ITEMS REMOVED FROM THE EXISTING FACIUTY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DEVICES (i.e. POWDER-ACTUATED) FOR ATTACHING HANGERS TO STRUCTURE WILL NOT BE PERMITTED. CLOSELY FOLLOW THE WORK. SHALL BE RELOCATED AS DIRECTED BY CONTRACTOR. EXTREME CAUTION SHOULD BE USED BY THE DESIGNATED LOCATION. UNES OF THE STRUCTURE, MAINTAIN CLOSE PROXIMITY TO THE STRUCTURE AND KEEP CONDUITS IN TIGHT ENVELOPES. CHANGES • CONTRACTOR WHEN EXCAVATING OR DRILLING PIERS AROUND OR NEAR UTILITIES. CONTRACTOR SHALL 14. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BE REMOVED FROM SITE ON IN DIRECTION TO ROUTE AROUND OBSTACLES SHALL BE MADE WITH CONDUIT OUTLET BODIES. CONDUIT SHALL BE INSTALLED IN PROVIDE SAFETY TRAINING FOR THE WORKING CREW. THIS WILL INCLUDE BUT NOT BE UNITED TO A) FALL A DAILY BASIS. A NEAT AND WORKMANLIKE MANNER. PARALLEL AND PERPENDICULAR TO STRUCTURE WALL AND CEILING LINES. ALL CONDUIT VERIZON SITE NUMBER:307842 PROTECTION B) CONFINED SPACE C) ELECTRICAL SAFETY D) TRENCHING AND EXCAVATION E) > SHALL BE FISHED TO CLEAR OBSTRUCTIONS. ENDS OF CONDUITS SHALL BE TEMPORARILY CAPPED FLUSH TO FINISH GRADE TO CONSTRUCTION SAFETY PROCEDURES. PREVENT CONCRETE, PLASTER OR DIRT FROM ENTERING. CONDUITS SHALL BE RIGIDLY CLAMPED TO BOXES BY GALVANIZED 11. ALL SITE WORK SHALL BE AS INDICATED ON THE STAMPED CONSTRUCTION DRAWINGS AND PROJECT MALLEABLE IRON BUSHING ON INSIDE AND GALVANIZED MALLEABLE IRON LOCKNUT ON OUTSIDE AND INSIDE. SPECIFICATIONS, LATEST APPROVED REVISION. CONCRETE. FOUNDATIONS. AND REINFORCING STEEL: 24. EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES AND PULL BOXES SHALL BE GALVANIZED OR EPDXY-COATED SHEET BU#:874135 12. CONTRACTOR SHALL KEEP THE SITE FREE FROM ACCUMULATING WASTE MATERIAL, DEBRIS, AND TRASH AT STEEL. SHALL MEET OR EXCEED UL 50 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND NEMA 3R (OR THE COMPLETION OF THE WORK. IF NECESSARY, RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER BETTER) FOR EXTERIOR LOCATIONS. WEST PORTLAND - REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY. 1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE ACI 301,ACI 318, ACI 336, ASTM A184, ASTM A185 AND 25. METAL RECEPTACLE, SWITCH AND DEVICE BOXES SHALL BE GALVANIZED, EPDXY-COATED OR NON-CORRODING; SHALL MEET OR 10955 SW 65TH AVE 13. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHICH INTERFERE WITH THE THE DESIGN AND CONSTRUCTION SPECIFICATION FOR CAST-IN-PLACE CONCRETE. EXCEED UL 514A AND NEMA OS 1 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND WEATHER PROTECTED EXECUTION OF THE WORK, SHALL BE REMOVED AND/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED 2. UNLESS NOTED OTHERWISE, SOIL BEARING PRESSURE USED FOR DESIGN OF SLABS AND FOUNDATIONS IS ASSUMED (WP OR BETTER) FOR EXTERIOR LOCATIONS. TIGARD,OR 97223 AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL TO BE 1000 psf. 26. NONMETALLIC RECEPTACLE, SWITCH AND DEVICE BOXES SHALL MEET OR EXCEED NEMA OS 2 (NEWEST REVISION) AND BE RATED OF CONTRACTOR, TOWER OWNER, CROWN CASTLE USA INC., AND/OR LOCAL UTILITIES. 3. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH (f'c) OF 3000 psi AT 28 DAYS, UNLESS NOTED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND WEATHER PROTECTED (WP OR BETTER) FOR EXTERIOR LOCATIONS. EXISTING 94r-O"MONOPOLE - 14. THE CONTRACTOR SHALL PROVIDE SITE SIGNAGE IN ACCORDANCE WITH THE TECHNICAL SPECIFICATION FOR OTHERWISE. NO MORE THAN 90 MINUTES SHALL ELAPSE FROM BATCH TIME TO TIME OF PLACEMENT UNLESS 27. THE CONTRACTOR SHALL NOTIFY AND OBTAIN NECESSARY AUTHORIZATION FROM THE CARRIER AND/OR CROWN CASTLE USA INC. - SITE SIGNAGE REQUIRED BY LOCAL JURISDICTION AND SIGNAGE REQUIRED ON INDIVIDUAL PIECES OF APPROVED BY THE ENGINEER OF RECORD. TEMPERATURE OF CONCRETE SHALL NOT EXCEED 90'f AT TIME OF BEFORE COMMENCING WORK ON THE AC POWER DISTRIBUTION PANELS. EQUIPMENT, ROOMS, AND SHELTERS. PLACEMENT. 28. THE CONTRACTOR SHALL PROVIDE NECESSARY TAGGING ON THE BREAKERS, CABLES AND DISTRIBUTION PANELS IN ACCORDANCE ♦ 15. THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE CARRIER'S EQUIPMENT 4. CONCRETE EXPOSED TO FREEZE-THAW CYCLES SHALL CONTAIN AIR ENTRAINING ADMIXTURES. AMOUNT OF AIR WITH THE APPLICABLE CODES AND STANDARDS TO SAFEGUARD LIFE AND PROPERTY. AND TOWER AREAS. ENTRAINMENT TO BE BASED ON SIZE OF AGGREGATE AND F3 CLASS EXPOSURE (VERY SEVERE). CEMENT USED TO BE 29. INSTALL LAMICOID LABEL ON THE METER CENTER TO SHOW "VERIZON". ISSUED FOR: 16. THE SUB GRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE PRIOR TO FINISHED TYPE II PORTLAND CEMENT WITH A MAXIMUM WATER-TO-CEMENT RATIO (W/C) OF 0.45. 30. ALL EMPTY/SPARE CONDUITS THAT ARE INSTALLED ARE TO HAVE A METERED MULE TAPE PULL CORD INSTALLED. SURFACE APPLICATION. 5. ALL STEEL REINFORCING SHALL CONFORM TO ASTM A615. ALL WELDED WIRE FABRIC (WWF) SHALL CONFORM TO ASTM REV DATE DAWN DESCRIPTION DES./I 17. THE AREAS OF THE OWNERS PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE TOWER, A185. ALL SPLICES SHALL BE CLASS "B'TENSION SPLICES, UNLESS NOTED OTHERWISE. ALL HOOKS SHALL BE CONDUCTOR COLOR CODE A 04/26,2021 RC PRELIDXNARI PL EQUIPMENT OR DRIVEWAY, SHALL BE GRADED TO A UNIFORM SLOPE, AND STABILIZED TO PREVENT STANDARD 90 DEGREE HOOKS. UNLESS NOTED OTHERWISE. VIEW STRENGTH (Fy) OF STANDARD DEFORMED BARS ARE EROSION AS SPECIFIED ON THE CONSTRUCTION DRAWINGS AND/OR PROJECT SPECIFICATIONS. AS FOLLOWS: SYSTEM CONDUCTOR COLOR o 0-/15/2021 RC EIS 1L PL #4 BARS AND SMALLER 40 ksi 18. CONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL A PHASE BLACK MEASURES, IF REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE LOCAL GUIDELINES #5 BARS AND LARGER 60 ksi B PHASE RED APWA UNIFORM COLOR CODE: FOR EROSION AND SEDIMENT CONTROL. 6. THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCING STEEL UNLESS SHOWN OTHERWISE 120/240V, 10 - 19. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND • ON DRAWINGS: NEUTRAL WHITE - -- STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3" GROUND GREEN OF OWNER. CONCRETE EXPOSED TO EARTH OR WEATHER: A PHASE BLACK MITEPROPOSED EXCAVATION 20. CONTRACTOR SHALL L I Y AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL #6 BARS AND LARGER 2' E'�I CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE #5 BARS AND SMALLER 1-1/2" B PHASE RED OW TEMPORARY SURVEY MARKINGS RETURNED TO THE OWNER'S DESIGNATED LOCATION. CONCRETE NOT EXPOSED TO EARTH OR WEATHER: 120/208V, 30 C PHASE BLUE SLAB AND WALLS 3/4' - ELECTRIC POWER LINES, CABLES,21. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BE REMOVED BEAMS AND COLUMNS 1-1/2" NEUTRAL WHITE RED CONDUIT, AND LIGHTING CABLES FROM 517E ON A DAILY BASIS. 7. A TOOLED EDGE OR A 3/4" CHAMFER SHALL BE PROVIDED AT ALL EXPOSED EDGES OF CONCRETE, UNLESS NOTED GROUND_ GREEN GAS, OIL STEAM, PETROLEUM, OR 22. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND. FROZEN MATERIALS, SNOW YELLOVICj" OR ICE SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT. A OTHERWISE, IN ACCORDANCE WITH ACI 301 SECTION 4.2.4. A PHASE BROWN GASEOUS MATERIALS T �f,Y�' . ` B PHASE ORANGE OR PURPLE : .- + COMMUNICATION, ALARM OR SIGNAL LINES, �� P. 277/480V. 30 C PHASE YELLOW 1R ^wI :`e CABLES, OR CONDUIT AND TRAFFIC LOOPS PETXR GREENFIELD GROUNDING NOTES: NEUTRAL GREY BLUE POTABLE WATER jICHO [ o GROUND GREEN RECLAIMED WATER. IRRIGATION.ANDlq 1. ALL GROUND ELECTRODE YTS!OAS (INCLUDING TELECOMMUNICATION, RADIO, LIGHTNING PROTECTION AND AC POWER GES'S) SHALL BE BONDED TOGETHER AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING CONDUCTORS IN POS (+) RED** PURPLE SLURRY LINES ' Aif� ACCORDANCE WITH THE NEC. DC VOLTAGE NEG (-) BLACK•• *WEST BLOOMFIELD,. 2. THE CONTRACTOR SHALL PERFORM IEEE FALL-OF-POTENTAL RESISTANCE TO EARTH TESTING (PER IEEE 1100 AND 81) FOR GROUND ELECTRODE SYSTEMS, THE CONTRACTOR SHALL FURNISH AND INSTALL SUPPLEMENTAL GROUND GREEN-' SEWERS AND DRAIN LINES ELECTRODES AS NEEDED TO ACHIEVE A TEST RESULT OF 5 OHMS OR LESS. • SEE NEC 210.5(C)(1) AND (2) M 3. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT AND PROVIDE •" POLARITY MARKED AT TERMINATION 6775 TESTING RESULTS. 4. METAL CONDUIT AND TRAY SHALL BE GROUNDED AND MADE ELECTRICALLY CONTINUOUS WITH LISTED BONDING FITTINGS OR BY BONDING ACROSS THE DISCONTINUITY WITH #6 COPPER WIRE UL APPROVED GROUNDING TYPE CONDUIT CLAMPS. ABBREVIATIONS: 5. METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR. STRANDED COPPER CONDUCTORS WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE FURNISHED AND INSTALLED OF O° WITH THE POWER CIRCUITS TO BTS EQUIPMENT. ANT ANTENNA 6. EACH CABINET FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER GROUND BAR WITH GREEN INSULATED SUPPLEMENTAL EQUIPMENT GROUND WIRES, #6 STRANDED COPPER OR LARGER FOR INDOOR BTS; #2 BARE SOLID TINNED (E) EXISTING COPPER FOR OUTDOOR BTS. FIF FACILITY INTERFACE FRAME 7. CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED BACK TO BACK CONNECTIONS ON OPPOSITE SIDE OF THE GROUND BUS ARE PERMITTED. GEN GENERATOR 8. ALL EXTERIOR GROUND CONDUCTORS BETWEEN EQUIPMENT/GROUND BARS AND THE GROUND RING SHALL BE #2 SOLID TINNED COPPER UNLESS OTHERWISE INDICATED. GPS GLOBAL POSITIONING STSILM 9. ALUMINUM CONDUCTOR OR COPPER CLAD STEEL CONDUCTOR SHALL NOT BE USED FOR GROUNDING CONNECTIONS. GSM GLOBAL STSILM FOR MOBILE 10. USE OF 90" BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 45' BENDS CAN BE ADEQUATELY SUPPORTED. LTE LONG TERM EVOLUTION 11. EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE. MGB MASTER GROUND BAR 12. ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR AND EXTERIOR) SHALL BE FORMED USING HIGH PRESS CRIMPS. MW MICROWAVE 13. COMPRESSION GROUND CONNECTIONS MAY BE REPLACED BY EXOTHERMIC WELD CONNECTIONS. (N) NEW NEC NATIONAL ELECTRIC CODE 14. ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED OR BOLTED TO THE BRIDGE AND THE TOWER GROUND BAR. 15. APPROVED ANTIOXIDANT COATINGS (i.e. CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND CONNECTIONS. (P) PROPOSED 16. ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT MATERIAL. PP POWER PLANT IT IS A 1101.ATION OF LOS FOR_1NY PERSON, 17. MISCELLANEOUS ELECTRICAL AND NON-ELECTRICAL METAL BOXES, FRAMES AND SUPPORTS SHALL BE BONDED TO THE GROUND RING, IN ACCORDANCE WITH THE NEC. OTT' QUANTITY L.NLESS,111E1'XRE:1CTING UNDER THE.DIRECTION 18. BOND ALL METALLIC OBJECTS WITHIN 6 ft OF MAIN GROUND RING WITH (1) #2 BARE SOLID TINNED COPPER GROUND CONDUCTOR. RECT RECTIFIER of_1 LICENSED PROFESSION\L ENGINEER, 19. GROUND CONDUCTORS USED FOR THE FACILITY GROUNDING AND UGHTNING PROTECTION SYSTEMS SHALL NOT BE ROUTED THROUGH METALLIC OBJECTS THAT FORM A RING AROUND THE CONDUCTOR, SUCH AS METALLIC CONDUITS, RBS RADIO BASE STATION To.S LIT R THIS DOCUMENT. METAL SUPPORT CLIPS OR SLEEVES THROUGH WALLS OR FLOORS. WHEN IT IS REQUIRED TO BE HOUSED IN CONDUIT TO MEET CODE REQUIREMENTS OR LOCAL CONDITIONS, NON-METALUC MATERIAL SUCH AS PVC CONDUIT SHALL BE RET REMOTE ELECTRIC TILT • USED. WHERE USE OF METAL CONDUIT IS UNAVOIDABLE (i.e., NONMETAC CONDUIT PROHIBITED BY LOCAL CODE) THE GROUND CONDUCTOR SHALL BE BONDED TO EACH END OF THE METAL CONDUIT. REDS RADIO FREQUENCY DATA SHEET W r 20. ALL GROUNDS THAT TRANSITION FROM BELOW GRADE TO ABOVE GRADE MUST BE #2 BARE SOLID TINNED COPPER IN 3/4" NON-METALLIC, FLEXIBLE CONDUIT FROM 24" BELOW GRADE TO WITHIN 3"TO 6" OF CAD-WELD TERMINATION RRH REMOTE RADIO HEAD SHEET NUMBER: REVISION: POINT. THE EXPOSED END OF THE CONDUIT MUST BE SEALED WITH SILICONE CAULK. (ADD TRANSITIONING GROUND STANDARD DETAIL AS WELL). RRU REMOTE RADIO UNIT TAD SMARTWR INTEGRATEDDEVICE T-20 21. BUILDINGS WHERE THE MAIN GROUNDING CONDUCTORS ARE REQUIRED TO BE ROUTED TO GRADE, THE CONTRACTOR SHALL ROUTE TWO GROUNDING CONDUCTORS FROM THE ROOFTOP,TOWERS, AND WATER TOWERS GROUNDING RING, TO TMA TOWER MOUNTED AMPLIFIER THE EXISTING GROUNDING SYSTEM, THE GROUNDING CONDUCTORS SHALL NOT BE SMALLER THAN 2/0 COPPER. ROOFTOP GROUNDING RING SHALL BE BONDED TO THE EXISTING GROUNDING STSIEM, THE BUILDING STEEL COLUMNS, TYP TYPICAL T...2 LIGHTNING PROTECTION SYSTEM, AND BUILDING MAIN WATER LINE (FERROUS OR NONFERROUS METAL PIPING ONLY). UMTS UNIVERSAL MOBILE TELECOMMUNICATIONS STSILM \ W.P. WORK POINT i" ,;>;/ /.4'..";.4,Y4--7),,, : 'N‹.1' 4-„i ",,,,i- k-----\ -„: t--... -----, 1.-- \.\ -- 1H SITE PLAN DISCLAIMER. JURISDICTIONAL APPROVAL: ,:--_----\ \ I-- i--\,--V V/ ,---,,„ - .,- -,1 iz ''14 , k------<7,1 --- /i -.' „--_-'- ' \ \i ----1 ''''.,,_ , /r - • ,,..t , ;t ..,4,-<-- 7‘,/ - , ,. .,..: ;,---,- ---.4 •vri 1,1,, -.---, ,...,.,:, \V, 'i",,. L--\--\,Vki tk'?- , PROPERTY UNES AND STRUCTURES HAVE BEEN DIGITIZED FROM PREVIOUS PLAN ,j, *<4/ /41 ' ier • ,,,-;//i.„,,,c.,,,,,.„ SETS. CROWN CASTLE USA INC. HAS NOT /.../ ,i'' ' COMPLETED A SITE SURVEY AND lig, '.•,''..,laby,'''''. ..._.' ''.---,-.\A'<-.-,j-...7..„,,, .(-<4-14,1,4,, '''.-41.gi . .,-.,,L,. THEREFORE IAAKES NO CLAIMS AS TO THE ACCURACY OF INFORMATION DEPICTED ON THIS SHEET. „,„,,,,,,‘, ..• > --_,4 ,_______ ,,,,,,-. .., .. , r 1' ! ' .q , . ,/11,, ,, --- •:.- A '-'-', -.7,,\k/ i s =. .. ;'. e-r--. '-->•l;-i:;',i--'=:-.7---4,,,'{1,/,,,1,,/,',=z/r i\4y 1' ',,-:,-,-q--<-,/'YI\&,/'M,Ti f“'' '-. (E) GRASS AREA ) ,...... /, (E) PARKING „ REE AEA 4 •, .. . , TREES AREA .A \ x._ --.:;* - - '1.---2-A s,::.i/ i I',• ' .(--" ./.. '` i , ,,, ' ,. \I ,SC-1 ''• v,,,, •-•* ---itt .„....... ,41._„...,-,'•• ,,,,,,,,,_,,,, , ',4 zi verizon ' Zil I 4.1 /1 l., , 1 3245 158TH AVENUE MS 231 ;,, '4,/.-kik . r/134,0,7>./ , ,-'47r• , k BELLEVUE,WA 98008 ; I'/ I — (E) SITE LOCATION .., . /, CROWN ›..---,,----' :-sk,,;.›.,-' ii'----- - ''''. 41?/ , ,,..//I i i , il:' \ <1/ ri= ‘: (E) 94.-0" MONOPOLE ii iv ' 1505 WESTLAKE AVENUE NORTH,SUITE 81 "'- '4'/:'''4I.,1-7'-'4, ',--..."1 -41 \fire4111,/71,-..\,_ ' ,„ , SEATTIE,WA 98109 „ ,,, Aim& .'.,,, , ' v,--,-*v ,,,,I.,,k0---- -,5 IA,,, 13 g 0 --,--,,, ,,.,irer - I •;!--, 4-i-,-.4,,,,: 49030 Pontiac Trail,Suite 400 i4.1\ </1,:;/)''A. ,.-r"r.,k'r,f40‘,- . 'TIT,. p-..1"y•jj-....chn, •-•., ^ /,,,;;,,,,,,,,,,i 4, :„,,,,,„,,,-' ,471., V''''t-i .-----.----- • Wixom,Michigan 48393 PHONE:(248)705-9212 .""":.-. ..\. ----.'"...9 '‘,.,:t'i ',5.7' i',--,:- ',.1,2. Iti / ,/- ‘,.,.--;`";-'7 I/\.,, , ' ,, -,"'*,/-,$.,AO exiv,, ..*',:,',„ / /.,-,- ,/ Aii, "4,, / I ,,, '"-"' 4F-Th,,,_c40 Arr.", :='-" 4---\"k i -' .--.1---?, W , - -'-'1. _ - -ii / VERIZON SITE NUMBER:30784 / e.. ,, •• i/1 : , .,,,W".' / WEST PORTLAND .._. , 41 , _/--• I ---, I . .4, / TIGARD,OR 97223 _ iNiN\-, ;- 4,,,,i-' t,.,:_,,,,- '''>-?-5,, Al I'l-,-,- ii -\,,,,, ,,,. i , II/ ri (E) BALDING-\ • EXISTING 94'-0"MONOPOLE , ir,-,-,...,,,,, ; ISSUED FOR: , , i . i REV DATE DAWN DESCRIPTION DES./ NNN. :E) GRASS AREA\ / ..T., --'"---.1 ! . ,f I \t/e,/iN . A 04/26/2021 RC PRELIMINARY 0 07/15/2021 RC FINAL PL PL • f , 6 ; . /11 , 4,1,311D 4440.06. .0;11, ---- NNN : ,-(E) GRASS AREA , , - I ....Y.A c:?7 PETER P. , --......___ , , LICHOMSKI 0 . ; ,, . . 'N. , i—1 .IVEST BLOOMFIEID,. MI N... „..._(E) PARKING lx. v(E) FIELD-11 NNNI , IT IS k VIOLATION OF I.AW FOR ANY PERSON, ',.. UNLESS THEY ARE ACTING UNDER THE DIRECTION \\ I OF A LICENSED PROFESSIONAL ENGINEER, N TO ALTER THIS DOCUMENT. • c)OVERALL SITE PLAN /,,,IIIIii, ni111111mIllih„ SHEET NUMBER: ' REVISION SCALE: § Iv i::ZO:TO:rt7TZE) N _ 1 • 1 0 l r n-to't JURISDICTIONAL APPROVAL: 33•-4•t 19•-10•± 19•-8•t • �./'��H-FRAME 1 14 FIBER/De VERIZONNES/ / _ y (3) HYBRID CABLES (1-3/8") verizon11/7 J / .,r 3245 158TH AVENUE MS 231 (E) VERIZON WIRELESS NEW VERQON FEEDUNE 4'-0"X8'-0" GEN PAD (1) HYBRIDCABLE (21 t BF.i.,.FVAV WA 98008 J /E) RIZON OW (3 TOTAL)�� (E) VERIZON WIRELESS CROWN 7'-99.-6"X0" PAD R A (E) VERIZON ICE BRIDGE 9'-6"X25'-0" AREA / BRIDGE (E) 94.-0" MONOPOLE ai: CASTLE NEW VERIZON OVP 505 WESTLAKE AVENUE NORTH,SUITE 800 (E) 5'-0"m SEATTLE,WA 98109 FND PIER 1 0 • (E) OTHER CARRIER ',¢ A °r -- -- V-OX1V-0" GEN PAD -H.. IB *Ia IN A 5'-0"X71'-0"AREA n0 49030 Pontiac Trail,Suite 400 i.P N 2 Wixom,Michigan 48393 aI O (E) OTHER CARRIER o ♦ PHONE:(248)705-9212 as - / 5'-OX5'-0" DOOR PAD V I � �'ERIZON SITE NUMBER:307842 BU#:874135 WEST PORTLAND /...------N (E) OTHER� CARRIER 10955 SW 65TH AVE (ABANDONED) TIGARD,OR 97223 4'-0"X4'-0" PAD EXISTING 94'-0"MONOPOLE ;••• / • 1 (E) OTHER ISSUED FOR: 11'-6"X28'-0" BUILDING/AREA REV DATE DRWN DESCRIPTION DES./Q. / 7/26/2021 RC PRELIMINARY PL 0 04/ /2021 RC FINAL PL / H-FRAME" UTILITY A 0 • t1 t I • _.._. _. _._. _..... _.._ _.._. _. _. I _... (E) XFRMR ON A `67� r 44C I I 4'-6"X6'-8- , moat P. A, PAD 4•-1•t 28"-0-± _ 12•-0"± 8•-9•± 4'-O"* 1•-10• 1 ± 2-5" �r1 - q LICHOMsKI n GATE .1 .WEST BLOOMFIELD,. MI 72-10•tI 9•,,, 6775 ,046* 4' OF 00 '�� (E) BOLLARD (TYP) FIB 2'-8"X4'-2" FIBER VAULT I i IT IS A VIOLATION OF LAW FOR ANY PERSON, 1 UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. • SHEET NUMBER: ' REVISION: DSITE PLAN � � 0 SCALE: 41,-fl,-To1/4--r-o (4' 1/8"�1'-0-(11 z17) ' • p. r. JURISDICTIONAL APPROVAL: • (E) UGFMNG ROD (E) LIGHTING ROD - - verizon‘i 3245 158TH AVENUE MS 231 ___: (E) OTHER CARRIER (E) OTHER CARRIER • BFT.i.FWE,WA 98008 _ ANTENNA (1YP) ANTENNA (TYP) �TO ELEV.OF MONOPOLE r ATOP OF ELEV.MONOPOLE �' � CROWN ANTENNA CL: 65•-0• ANTENNA CL_ e15•-0• I a%:•04% CASTLE MOUNT CL: 82•-0" MOUNT CU 02•—O• ' _ IJ 1505 WESTLAKE AVENUE NORTH,SUITE 800 SEATTLE,WA 98109 Isa LAB I (E) VERIZON EQUIPMENT TO REMAIN 11 (E) VERIZON EQUIPMENT TO REMAIN---\ 49030 Pontiac Trail,Suite 400 (3) OVPs i,' (3) \. 8393 INSTALLED ON EXISTING MOUNTS a OVPs Wixom,Michigan-9212 �� INSTALLED ON EXISTING MOUNTS , ♦ PHONE:(248)7059212 1i31 ♦ i i Il 1 (E) VERIZON EQUIPMENT TO BE RELOCATED I' (6) ANTENNAS I (E) VERIZON EQUIPMENT TO BE RELOCATED TIP OF ANTENNA k (6) ANTENNAS TIP OF ANTENNA 0 VERIZON SITE NUMBER:307842 (6) RRHs INSTALLED ON EXISTING MOUNTS(6) RRHs INSTALLED ON EXISTING MOUNTS' I, ELEV. = 69'—O" i RAD OF ANTENNA I% RAD OF ANTENNA BU#:874135 sf ELEV. = 65'-0" ELEV. = 65'-0" N WEST PORTLAND i-' — paw vzwswar—Macs UNIVERSAL ANGLE10955 SW 65TH AVE k�1 CONNECTION HORIZONTAL ewAru�cCORNER CONNECTION BRACKET�Dori� TIGARD,OR 97223 (E)VERIZON EQUIPMENT TO(eB)E NEW VERIZON ANTENNAS )�- MP SW) RAIL PIPE(3 TOTAL 1 rr EXISTING 94 0 MONOPOLE INSTALLED ON DOSIIMC(e (3)sDE BY DOE ANTENNA MOUNT NEW VZWSMART-PLK8 SUPPORT BRACING • MOUNTS (OOINSOOPE P/NcBSAMif-a35-t-2), (E) VERIZON FEEDUNES (3) RRH , KIT(3 TOTAL. 1 PER SECTOR).` ' (3) HYBRID CABLE (1-3/8") I I1•ALL ON COSTING(1MOUNTS ISSUED FOR: 1 NEW LIDYSLURT-MSIC10 WIRE ROPE RLV DATE DAWN DESCRIPTION DES./Q., A 1 ROUTING 8RAC10=T 04/26/2021 RC PRELISIINARI' PL (E)VERIZON FEEDUNES a 07/15/2021 RC FINAL PL E (E) 94'-0" MONOPOLE (3) HYBRID CABLE (1-3/87 NEW VERIZON FEEDUNE (1) HYBRID CABLE(2') ♦ (E) 94'—O" MONOPOLE (E) VERIZON WIRELESS —(E)VERIZON"WIRELESS 4.I ���(y'- (E) VERIZON ICE BRIDGE 7-9"X75'-0" PAD IN A !' (TYP) j 9—6"X25'-0"AREA (E) VERIZON ICE BRIDGE 9'--6"%25—0"AREA IN A �� PETER P. `l'1, At LICHOMs i b F (E) VERIZON WIRELESS 4'-0"X8'-0" GEN PAD 4.-0"X81.ON WIRELESS GEN PAD �� �nn • JDJOJMFMIW,• MI \ 6775 e . , : ...., , 1 , , ...., , ., „ ,_, OF O ' "Iloilo:- I, ; 1 1 E. i I s, I � NIA L_�I_1I6 1 I j I i t ,, I I IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICFNSED PROFESSIONAL ENGINEER, 10 AUFER TI IIS DOCUIIEN C ♦ SHEET NUMBER: ' REVISION: O EXISTING NORTHEAST ELEVATION O FINAL NORTHEAST ELEVATION _n O SCALE: NOT TO SCALE 2 SCALE: NOT TO SCALE G r i JURISDICTIONAL APPROVAL: ANTENNA SCHEDULE CABLE SCHEDULE RATER D ANTENNA MECH. ELECT. TOWER MOUNTED SECTOR POS. TECHNOLOGY C EN AZIMUTH M ANUFA ANTENNA MODEL TILT TILT EQUIPMENT FEEDLINE TYPE STATUS CABLE TYPE SIZE QUANTITYC _TE 700/LIE 5G/LTE 850/LTE ALPHA iE AWS/AW53 65'-0" 60' ANDREW SBNHH-1 D65C 0' 0' RCMDC-3315-PF-48 HYBRID EXISTING HYBRID 1-3/8" 3 Al _TE 700)LTE 5G/LIE 850/LTE ALPHA PCS/LTE AWS/AWS3 65'-0" 60' ANDREW SBNHH-1D65C 0' 3' - HYBRID NEW HYBRID 2* 1 ALPHA A2 - - - - Cr 3' WOO 4449 HYBRID FINAL CABLE QUANTITY 4 ALPHA A3 - 65'-0" - - - 0. (1) ERICSSON RRUS32 B66A (1) ERICSSON RRUS32 B2 HYBRID ALPHA A4 5G 65'-0" 60' ERICSSION NR6449 0' 0' RVZDC-6627-PF-48 HYBRID BETA B1 50 : 65'-0" 180' ERICSSION MR6449 O 3" — HYBRID BETA B2 - 65'-0" - - - 0. (1) ERICSSON RRUS32 B66A (1) ERICSSON RRUS32 B2 HYBRID • BETA B3 - 65'-0" - - - 0' 0' RADIO 4449 HYBRID ,� �'� � BETA _TE 700/LTE SG/LTE 850/LTE 65'-O" 180' ANDREW S8NHH-1D65C 0' 3' - HYBRID B4 PCS LTE ANS/ANS3 _TE 700 LTE 5G/L1E 850/LTE 3245 158TH AVENUE MS 231 BETA 65.-0" 180' ANDREW SBNHH-1D65C 0' 10' RCMDC-3315-PF-48 HYBRID BET.i EVUE,WA 98008 PCS/LTE AWS/AWS3 ♦ BETA B5 5G 65'-0" 240' ERICSSON VZ-NR6701 TB 2' 6' - - • CROWN _TE 700/LTE 5G/LTE 650/LTE CASTLE GAMMA f 65'-0" 300' ANDREW SBNHH-1D65C 0' 10' RCMDC-3315-PF-48 HYBRID 0:11.00114 PCS LTE AWS/AW53 C l _TE 700 LIE 5G/LIE 85G/L1E 505 WESTLAICE AVENUE NORTH,SUITE 800 GAMMA PCS/L1E AWS/AWS3 65'-0" 300' ANDREW SBNHH-1D65C 0' 3' - HYBRID ` SEATTLE,WA 98109 GAMMA C2 - 65'-0" - - - Cr RADIO 4440 HYBRID GAMMA C3 - 65'-0" - - - 0' 0' (1) ERICSSON RRUS32 B66A LAA, (1) ERICSSON RRUS32 B2 HYBRID GAMMA C4 5G 65'-0" 300' ERICSSON NR6449 0' 3" — HYBRID 49030 Pontiac Trail,Soda 400 Wixom,Michigan 48393 GAMMA CS 5G 65-0" 0' ERICSSON VZ-NR6701 'TB 5' 6' - - • PHONE:(248)705-9212 VERIZON SITE NUMBER:307842 ANTENNA AND CABLE SCHEDULE SCALE: NOT TO SCALE BU#:874135 WEST PORTLAND 10955 SW 65TH AVE C5 I TIGARD,OR 97223 A NEW VERIZON SIDE BY SIDE ANTENNA EXISTING 94'-0"MONOPOLE _ r� (E) VERIZON RRH TO BE RELOCATED /' 'i C,\ �(6 TOTAL 2 PER SECTOR) / P \\ R: SB5 1-2) (3 TOTAL. 1 ♦ C4 / / ' Al C4 / > -'\ Al RELOCATED (E) VERIZON ANTENNA ISSUED FOR: / • (E) VERIZON OVP TO REMAIN a 1 +p� � `� (3 TOTAL) NEWON OVP _ ,i, ki j \.A-A♦,�\- (6 TOTAL, 2 PER SECTOR) +--t t ry. ,\ J REV DATE DAWN DESCRIPTION DES./Q r� CV \` i■ / 4 04/26/2021 RC PRELIMINARY PL .. \\ !5 0 07/15/2021 RC FINAL PL + AY\\ \\ (E) VERIZON ANTENNA TO BE RELOCATED _ 4,:,•, 1\\ \ (6 TOTAL, 2 PER SECTOR) h +` \\\\\` (E) VERIZON OVP TO REMAIN (3 TOTAL) \\ CO / ii Ai AZ - //!n1- =fit+ tr` •���. A2 '` (GAMMA) ! �.x \\A\\A� ..\ \ GAMMA) CO i�' <. FYI , _ "V�\�� 300' AZIMUTH / \\\\ \\ 4 (ALPHA) ( �� j \\\\\\\\ \\tom 60' AZIMUTH 30Gd0'AZIMUTH / . r! \\\\\\ \\ / 1st _ \,\\\\\\\\\�/�// eV AZIMUTH / \\ \\\\\ "" so. - A /� `: I;, 1\\ \\\\\ (E)VERIZON RRIi TO BE REMOVED / \l\\ \\ X (3�T AL. PER SECTOR) \\\\ (6 TOTAL. 2 PER SECTOR) / III , \\ D / \ \\ \\\\\ / �t\ C' C2 \ / \\\\\\\\%\\\\\ c2 :./ _ l\ ``\\\\\`���\\\ ROUiINGNEW V BWKa(ETMSK10 WIRE ROPE ..,_ PRIME P. ' ' / / 110 \ \\\\\ \ A3 I / \\\,�,\\\` A3 RELOCATED (E) VERIZON RRHr�y�..* r VA\�\A\\AV�♦�� (6 TOTAL, 2 PER SECTOR) �I ��UaJa71�i ,�� WEST BLOOMFffiA . / (E)VERIZON ANTENNA TO BE REMOVED 'r d / '-� NEw VERIZON ANIMA • f / \ > ( TOTAL 2 PER SECTOR) (5EAUct Aaa W% 4 ``���Aa / i.. Jf/, V\\\V AyA4\�+�� ►mow vzwswRr-MSK8 u MMAL ANGLE ' ' ,. > ` .:.—. ` -, r 1` \\`\•\\i`` CONNECTION HORIZONTAL BRACINGCORNER CONNECTION BRACKET ON D 0, '— 'er.�+F+z! i. II, I y " 4;, ter".. —— \l\�\1` _ PER '� _ _ __ TOP SUPPORT PIPE(3 1 Y e _:.. - .......�>tr_, • ti/ _l 6 Y -� — � • --NEW SECTORRi-PL1G8 SUPPORT BRACING �=— ----�t-✓�- (..� iip .. -- V., -�'�i� // ill A5 KR(3 TOTN. 1 PER SECTOR) t. �L XB5 101. ._) IT IS A VIOLATION OF LAW FOR ANY PERSON, (BETA) (BETA) f $ UNLESS THEY.ARE ACTING UNDER THE DIRECTION 1 SO' AZIMUTH Bt - 3) t80'l240' AZIMUTH 1 1 OF A LICENSED PROFESSIONAL ENGINEER, B4 83 B2 Ba _ B3 I B2 1'-0't 2'-0't TO ALTER THIS DOCUMENT. 1 i e SHEET NUMBER: REVISION: 1CD EXISTING ANTENNA PLAN iN ICD FINAL ANTENNA PLAN ^ SCALE: NOT TO SCALEyr ' ®SCALE: NOT TO SCALE _3 / e- JURISDICTIONAL APPROVAL: AIR 6449 — n77D / C-Band max measurements/will not exceed 0 Spectrum n77D C-Band(3.7—3.98 GHz) OpBW 280 MHz IB W/CB W 200 MHz MU-MIMOLayers 16DL/8UL Output Power/EIRP Up to 320 W/79 dBm Antenna Active Antenna System(AAS) Branches/Elements 64Tx/64Rx with 192 antenna elements Size and Weight: 3 s°0 i<9a+x1 wa:ghl.4kggEz:' NM Ill Iiiii • , wo protruding dams 304In 1591n , . , ver'Zoni (772mm) (ass aim) (206mm) 66 MF... wprotrudinp items 30.81n 16.11n 108 In (39.9 KO) 3245 158TH AVENUE N[5 231 (763mm) (486mm) (273mm) BEJ.J.FVUE,tW A 98008 #CPRI ports: 4 x 25 Gbps eCPRI -- (compatible to 10G—eCPRI SFP28) CROWN 1 Power Input -48 VDC ✓v CASTLE Operational Conditions: -40*to«55°C.(Inc!Solar Load) Power: max 1360W(80%TX-20%RX) 1505 WESTLAKE AVENUE NORTH,SUITE 800 SEATTLE,WA 98109 ♦ 262.11.19 I CarnnM v,CvSbna t P9R t ! L1_..' ,B 49030 Pontiac Trail,Suite 400 Wixom,Michigan 48393 PHONE (248)705-9212 1 VERIZON SI 1'E NUMBER:307842 C)SUB6 ANTENNA MANUFACTURER DETAIL — FOR REFERENCE ONLY NOT USED SCALE: NOT TO SCALE OSCALE: NOT TO SCALE BU#:874135 WEST PORTLAND 10955 SW 65TH AVE le TIGARD,OR 97223 EXISTING 94'-0"MONOPOLE • ISSUED FOR: REV DATE DRIT'N DESCRIPTION DES./Q\ { 04/26/2021 RC PRELIMINARY PL 1 it 07/15/2021 RC FIN_U. PL Radio 8843 & 4449 RADIO RADIO • oar.Rd Radio8843 Radio4449 8843 4449 i and 6ad211sa0) 8andb6A(2.ICw_; e>I,di3Lnaac) ewat ) I hePeRir Ot:193b'19.0MIR DI:211a'x1/0M¢ -',"".�81 746756MN1 Ct:861134Mtk '..,. 1 U1:I850-19W6961 IR'1710•I780Mie 1 tit 777'787a0n lit:814'6M6tlk w sown 701414x I tom, n6w Preliminary 66wn 0 W_ J. 10WM _ Sot 1 C•RrOrardt6 5,10,13.29M1k J p6W S.W.I5.16Y1t rj L 1 tood4•I mehe yb 2lprradoaa both wn& 1 rpa24pr re*a-000 adt _ '-'� � `i1 �t.. �� I Of Chin 47O,214R 2T2R(SWtat6/v166e) I 4T4R.2t4R,272R(AY<adprakt) MOUNTING BRACKET—� "'�' I ,! •Oayi parr 120N { VOW ,^.�,. (SUPPUED W/ANTENNA) 1\, ' PE1II P. areniNIR Twe 62166W►.28f2®ap1Rt 7lpral:M3:.1a53,6510S 1 n 1Ra " � Jik 04,4t/��i���t/p��1VRt6N1Mtt 123rrytadl 9Y aAU I 6MR 61f1iMt5%,256MMt13YMM A/ L CHOMSKI A U,WPo IV-96SOUt 3I.TB.SVOC 4 Fwrr/1 y 4V171:::: pw•Caw Edon IM KR16xdytgei ; welesmMc�u.at, .W84P BLOOMFIE D,. wakesMI ' srd6na MOUNTING PIPE -�' `� 6775 NEW Sam ie9Wm' 28`cISNIO' ffi"slltio` " �—ANTENNA _'C71� eWOW Eke ISIbt 0p6sWlt talpawrre -40'CF4D'!')' '[)131'%IMRd•rt•>Yr b+A -i8'C;-4D'P')-ssct131'/(i'R6Mgt mrraaB ,, • , Cooing ilahpaltonweRen 6ao�te.�tion '�' OF p�L4'' iar cowde rptu1pats __ rap to4ports — t Oplk Nealxe ICPR40m:25656,100,11,1ia 2cpMpW 23656106,1k164m INSTAI I FR NOTF: I RIitMll kww6ate 1 ALDRSft pat 14at 1AURt6T pore MW 40 ,y i NWT Sr nerted0n 2 R6pro160pneaewft One We, S461'08 2RJ ports(Ow pi-nanpensoft M . I 1 HARDWARE TO BE.ALL PIPES, K GALVANIZEDETS, AND IS MISCELLANEOUS wood pen sper:Me Ow WNR secant pat NppOnsAeatx MAR �� NOTED OTHERWISE. LESS �l1 i Meg 1u3:6e.Mnd srd',attains 4uoien war cxwr.03. }l / "6elaaw•d9a6ap; .� f �-MOUNTING BRACKET (SUPPUED W/ANTENNA) II'is A VIOLATION OF LAW FOR ANY PERSON, l:\LI�:SS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER TO ALTER THIS DOCUMENT 4 ANTENNA MOUNTING DETAIL SHEET NUMBER: 1' REVISION: OERICSSON RRUS 8843 & RRUS 4449 MANUFACTURER DETAIL — FOR REFERENCE ONLY 4 SCALE: NOT TO SCALE SCALE: NOT TO SCALE C—4 O V i r JURISDICTIONAL APPROVAL: 17;ra=•" Ie.. kJJCI Mil 060 I900 AWS AwS.i 2e 31 39 CURS LAA L-Sax Malls Mufti Canteens rip 4xnwm RE as Fix zit Oz rash Gila Gha Gltx Haight Tyre SO EAcsanrt YZ-Ain6701 T8 6' 65.e ) Wow tither PHYSICAL. 1 240(0 240100021 60660011 SG TSD nL-Sube Antenna 66 07.1 1SO(0002) fade Mee PHYSICAL 3 300(00031 10C 650 ?W)0 AWS AW53 26 31 39 C5RS LAA LSa:b Oahe Mudol Cw.tt.•ira rp aa'mw.)th ;VT Lehi Hal Q4,11ty ChM Gltt Gllr IWght Tree Amino* 581161H-11: le 65C 66 60 604CM) lake fake SPARE 6 Ve r i zo n 3000131 3245 158TH AVENUE MS 231 BELLEVUE,WA 98008 . at. CROWN 700 WO 1900 AfkS AwS7 28 01 39 CURS LAA I.S...D w1M&Mate Modal C - w ^,v Aa 5.tulh RET 1,fL 4i 0..r+bd?ty al:, C�tHt STL^Gila 04-ba GYtz Heltih1 Type LTE 80i01! 1505 WESTLAKE AVENUE NORTH,SUITE S00 LT! LTE LTE LTE Af1OREW 58M1$-r065C 85 69 1601023 Iv. true PHYSICAL SEATTLE,W.398109 SO 300:031 LAB 49030 Pontiac Trail,Suite 400 Wixom,Michigan 48393 PHONE:(248)705-9212 VERIZON SITE NUMBER:307842 Equipment. .Si.r'tt3tT`a'=` BU#:874135 WEST PORTLAND 10955 SW 65TH AVE TIGARD,OR 97223 Ea uIprne1t TYpb Lodi`-un 700 650 1900 AWS AWS3 28 GPI 31 G►t4 39 Gil CBRS LAA L-Sub' Moe Model Cane Length Cable size ) ita11 Typo OwnLsy EXISTING 94'-0"MONOPOLE LTE RRU Tamer LTE Ericsson 4449 PHYSICAL 3SG ISSUED FOR: Hybrid Cobb Tower Nay MLCH 12124 PHYSICAL 1 REV DATE DRWN DESCRIPTION DES./Q.i A 04/26/2021 RC PRELIMINARY PL OVP Box Tower Raytcap QVP 12 PHYSICAL 1 0 07/15/2021 RC FINAL PL OVP Box Shettsi' Ftaycap OVP 12 PHYSICAL 1 Equipment T Mel Locatlan 700 850 1900 AWS AW 53 28 GPL 31 GHf 39 Gil CBRS LAA L-5obl Mske Mude4 Cobh)Length Coble Size Instal Type Quantity RRU Tower LTE Erlceaon 2212 8i3 PHYSICAL 6 ,Q_j) Equipment Type Location 700 850 1900 AWS AWS3 28 G H1 H. 31 G 39 Gil CBRSMtftti LAA L•Subt Make tkft Cable Length Cable Size Install Typo O orrUty t/ p iR p� RRU Tower LTE Ericaeon RRUS32 B2 PHYSICAL 3 : LICH0 PA"'] •wssr noomptuD,. RRU Tower LTE LTE Ericsson RRLIS32 8156A PHYSICAL 3 Ida HYtb Cable Tower MUCH 6,'12 PHYSICAL 3 tir,� 6775 Cp OVP Box Tower OVP 6 PHYSICAL 3 ' OF O1 OVP Box Shearer OVP 6 PHYSICAL 3 lam' IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO-ALTER THIS DOCUMENT. O RFDS SCALE: NOT TO SCALE SHEET NUMBER: ' REVISION: C -5 o i JURISDICTIONAL APPROVAL: [005585,305585J FUR—VILLA RIDGE[ 3 Sectors—4x4 REF RRH(700,850,PCS,AWS1,AWS3)+850NR+L-Sub6} (SG-2 Sectors-28 GHz) • verizon sic.i SKIM 35005 1 • 3245 158TH AVENUE MS 23) I BELLEVUE,WA 98008 es M r CASTLE CROWN _ OM • - \: l_th.^1..3 B�iLF...l ! [.a .I !Ii�.....1 mow 11=117MLlm r, = I505 WESTLAKE AVENUE NORTH,SUITE 800 VIM sg1, © zaM— ..m E ,` SEATTI. .198109 _ ______� ` E. W'. 'ett-71/71" killtit114 101711 I.AB 49030 Pontiac Trail,Suite 400 Wixom,Michigan 48393 PHONE (248)705-9212 • awe--w. U LJ ® © 8 , U u `( Lj VERIZON SITE NUMBER:307842 ...at. BU#:874135 WEST PORTLAND 10955 SW 65TH AVE .iiiii.I* .1''rgi4 .1.66.I TIGARD,OR 97223 - "�`If LI " EXISTING 94'-0"MONOPOLE r 1 ISSUED FOR: 44 ..^ .._.._ .... RFV DATE DIMN DESCRIPTION DES./Q1 A 04/26/2021 RC PRELIMINARY PL 0 0715/2021 RC FINA1. PL I,If I.I.I 14.n.I44.f444. A. �.l.r. SC l>)�.a..l*la C .n / 4 I Ili* a +I{�� 3MMOMMI a�w j #fir yg 1 tjtl.t.ial+i rrrente(�itTer 1:1,1 l+[+P1 1 ri:Im,...I 4Sv-" e ag PE P. '0 LICHOMSIQ H Ott Carol Orb Mrs. AN Smart Matra tSSTraatartmi lime au A� land 43 ratarmai o. **t"I. *c.. a*9. b. BBOW 4 ind •wWEST BLOOt•'t:I, '• tM W amar MI 503 Barad Emrsaia. -r a3--- qua;. O1 6775 Cp tktwn it _ Brat Al 6. "S'4*1*. a! )waiaaan Lt7F 4 S�.r.� OF O ' I crccc e n IT IS_A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY:IRE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. OCONFIGURATION DIAGRAM SCALE: NOT TO SCALE SHEET NUMBER: REVISION: C -6 0 , , i i JURISDICTIONAL APPROVAL: 8" PVC PLUG TO ANTENNA COAX TO ANTENNA COAX / / 8' PVC PLUG CPLG. (THRD.) T/FlNISH GRADE ,� — COPPER/GALVANIZED GROUND BAR COPPER/GALVANIZED GROUND BAR �� / f io8o80000000o00o0io =[=zdVirK=Zff,=z=i=1itfikrilko=[=z=z o o 0000000000000041/0.11 �T�Y Y•��Y, IteY �Y4 �YIIIlllppppppllllll Z . s'0 0 0 00000000000000 000000000000000 ���� �,t.•�•�•�.•�.•�•� © 000 0000000000000000 © ©; o0000000000000000 a ,,�Y-,�Y Y:�Y:�[:�Y-,�Y-wY:�T:ir SUBGRADE H o #2 SOLID (TEST LOOP) #2 SOLID TINNED COPPER z CONDUCTOR TO TOWER/SHELTER z • / NOTCH SIDES OF 8' PVC SCH 40 PIPE GROUND RING (2 TYP. FOR r, MI / TO ALLOW EXIT/ENTRANCE OF ---- TWO HOLE LONG BARREL TWO HOLE LONG BARREL COMPRESSION LUG LT., COMPRESSION LUG (TYP) (TYP) BOTTOM GROUND BAR ONLY) o EXOTHERMIC WELD GROUND RING WIRE IF • NOTES: NOTES. 1 t —I —I I I— —Ill' I—III ,\I I--‘(I 1- 1. DOUBLING UP "OR STACKING' OF CONNECTIONS IS NOT PERMITTED. 1. EXTERIOR AN110XIDANT JOINT COMPOUND TO BE USED ON ALL EXTERIOR CONNECTIONS. 'O \ TRENCH BOTTOM 2. EXTERIOR ANTIOXIDANT JOINT COMPOUND TO BE USED ON ALL EXTERIOR CONNECTIONS. 2. GROUND BAR SHALL NOT BE ISOLATED FROM TOWER. MOUNT DIRECTLY TO TOWER STEEL (TOWER ONLY). \'--- f 2/0 TINNED CU EXTERNAL `Y/ 3. GROUND BAR SHALL NOT BE ISOLATED FROM TOWER. MOUNT DIRECTLY TO ANTENNA MOUNT STEEL. 3. GROUND BAR SHALL BE ISOLATED FROM BUILDING OR SHELTER. CADWELD TEST LOOP TO \ TOWER GROUND RING WIRE verizon GROUND RING WIRE NOTES 5/8" 0 x 10'-0" LONG COPPER CLAD GROUND ROD 3245 158TH AVENUE MS 231 1. GROUND ROD SHALL BE DRIVEN VERTICALLY, NOT TO EXCEED 45 DEGREES FROM THE BELT EVUE,WA 98008 VERTICAL 2. GROUND WIRE SHALL BE MIN. 30' BELOW GRADE OR 6" BELOW FROST UNE. (WHICH EVER IS GREATER) AS PER N.E.C. ARTICLE 250-50(D) CROWN : CASTLE 1505 WESTLAKE AVENUE NORTH,SUITE 800 ANTENNA SECTOR GROUND BAR DETAIL TOWER/SHELTER GROUND BAR DETAIL INSPECTION WELL DETAIL SEATrLE,WA98109 SCALE: NOT TO SCALE OSCALE: NOT TO SCALE ®SCALE: `NOT TO SCALE LAB Y v 49030 Pontiac Trail,Suite 400 Wixom,Michigan 48393 PHONE:(248)705-9212 STAINLESS STEEL BOLT VERIZON SITE NUMBER:307842 (TYP) TO TOWER MOUNTED EQUIPMENT STAINLESS STEEL (TYP) FLAT WASHER BU#:874135 TO ANTENNA MONOPOLE 2-HOLE CRIMP/ (TYP) WEST PORTLAND COMPRESSION ,-ANTENNA GROUND BAR CONNECTOR TIT: SR AVE LOCATED AT MCL __I (BONDED TO TOWER STEEL) ' GROUND TIGA9SS RD,OR6STH 97223 STANDARD COAX I BAR 2 HOLE LUG (TYP) EXISTING 94'-0"MONOPOLE CABLE GROUND KR (TOP) STAINLESS STEEL FLAT WASHER #6 STRANDED CU WIRE WITH----"AiriSTAINLESS STEEL (TYP) GREEN, 600V, THWN BELLVILLE WASHER STAINLESS STEEL NUT i 6"WIDE METALLIC HTEL ISSUED FOR: INSULATION (OR AS PROVIDED (TYP) (TYP) GRADE WARNING/LOCATOR TAPE AT WITH GROUND KIT) (TYP) I- SINGLE CONNECTOR AT GROUND BARS 12' DEPTH REV DATE DRWN DESCRIPTION DES./QA N A 04/26/2021 RC PRELIMINARY PL STAINLESS STEEL BOLT o 0 07/15/2021 RC FINAL PL MECHANICAL CONNECTION / z (TYP) �� STAINLESS STEEL 6. i COAX GROUND BAR WITH FLAT WASHER w"-• EXOTHERMIC WELD '/;-- COAX CABLE INSULATORS, CONNECTED I (TYP FOR ALL) DIRECTLY TO THE BOTTOM DRAGON TOOTH WASHER -OF MONOPOLE. SEE NOTE 1. (nR) I. STEELII TO BAY ER MENT VIA 2/0 TINNED BARE TRAY OR ICE BRIDGE COPPER WIREIC 2-HOLE CRIMP/ • \�MONOPOLE PIER COMPRESSION STAINLESS STEEL GROUND RING #2 COPPER WIRE ll' /1 m5. -... ... --- CONNECTOR FLAT WASHER SOLID, TINNED FOR CARRIER AND ICE i GROUND WIRE ��� (TYP) BRIDGE GROUND LOOP GROUND WIRE �� / SEE NOTE 3 STAINLESS STEEL STAINLESS STEEL NUT GROUND RING 2/0 FOR Ch **PETER P• A NOTE 3zzil_ BELLVILLE WASHER (TOP) LL 1�f`Q714`TL \ (TYP ) TOWER GROUND LOOP FwKi/1/ - -ii—s SINGLE CONNECTOR AT STEEL OBJECTS � T Pi �}p INSPECTION WELL EXOTHERMIC WELD (TOP) .WEST M' ✓0• i MI NOTES: I� STAINLESSSTEEL — `^ SELF-DRILLING STAINLESS STEEL 6775 1. NUMBER OF GROUNDING BARS MAY VARY DEPENDING ON THE TYPE OF TOWER, ANTENNA METAL SCREW ! FLAT WASHER LOCATIONS AND CONNECTION ORIENTATION. COAXIAL CABLES EXCEEDING 200 FEET ON THE (TOP) / (TYP) GROUND ROD COPPER TOWER SHALL HAVE GROUND KITS AT THE MIDPOINT. PROVIDE AS REQUIRED. '' �� CLAD STEEL ROD W/MIN. , e " OF 5/8 0 x 10'-0" LONG O 2. ONLY MECHANICAL CONNECTIONS ARE ALLOWED TO BE MADE TO CROWN CASTLE USA INC. 2-HOLE CRIMP/ - - 0m■ TOWERS. ALL MECHANICAL CONNECTIONS SHALL BE TREATED WITH AN ANTI-OXIDANT COATING. COMPRESSION • T CONNECTOR t 4 3. ALL TOWER GROUNDING SYSTEMS SHALL COMPLY WITH THE REQUIREMENTS OF THE RECOGNIZED EDR10N OF ANSI/TIA 222 AND NFPA 780. DRAGON TOOTH — METALLIC OBJECT NOTES: WASHER 1. GROUND ROD SHALL BE DRIVEN VERTICALLY, NOT TO EXCEED 45 DEGREES FROM THE (TOP) VERTICAL SINGLE CONNECTOR AT METALLIC/STEEL OBJECTS 2. GROUND WIRE SHALL BE MIN. 30" BELOW GRADE OR 6" BELOW FROST UNE. (WHICH EVER IS GREATER) AS PER N.E.C. ARTICLE 250-50(D) IT IS.{VIOLATION OF LAW FOR ANY PERSON, L'EI.7-:SS THEY ARE ACTING UNDER THE DIRECTION ®TYPICAL ANTENNA CABLE GROUNDING HARDWARE DETAIL FOR EXTERIOR CONNECTIONS GROUND ROD DETAIL OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SCALE: NOT TO SCALE OSCALE: NOT TO SCALE ©SCALE: NOT TO SCALE SHEET NUMBER: r REVISION: G- 1 0 r r \ WIRE SIZE BURNDY LUG BOLT SIZE JURISDICTIONAL APPROVAL: *— % 'Ml .444 #6 AWG GREEN INSULATED YA6C-2TC38 3/8" - 16 NC S 2 BOLT TYPE HS TYPE 2-YA-2 TYPE XA TYPE YA-2 TYPE GY #2 AWG SOUD TINNED YA3C-2TC38 3/8" - 16 NC S 2 BOLT #2 AWG STRANDED YA2C-2TC38 3/8" - 16 NC S 2 BOLT #2/0 AWG STRANDED YA26-2TC38 3/8" - 16 NC S 2 BOLT TR" I *, ��; #4/0 AWG STRANDED YA28-2N 1/2" - 16 NC S 2 BOLT TYPE V1/ TYPE VN TYPE N( TYPE SS TYPE GR BURNDY GROUND LUG W/-\ HEAT SHRINK LONG BARREL (CLEAR) i .:i G,\ (SEE CHART) `\p .4 ( )_ 't GROUNDING \\ CONDUCTOR ��% �� LOCK WASHER .. .. _ �J (TMP) =•• TYPE VS TYPE VB TYPE PT TYPE GY NOTE: �.n �.0 verizon`' �` GROUND BAR BOLT 1. ERICO EXOTHERMIC "MOLD TYPES" SHOWN HERE ARE EXAMPLES. CONSULT WITH CONSTRUCTION MANAGER FOR SPECIFIC �" -(SEE CHART) 3245 158TH AVENUE MS 231 MOLDS TO BE USED FOR THIS PROJECT. / \ (TYP) BFT.I.FVUE,WA 98008 2. MOLD TYPE ONLY TO BE USED BELOW GRADE WHEN CONNECTING GROUND RING TO GROUND ROD. �-BURNDY TWO HOLE LUG W/ LONG BARREL CROWN OCADWELD GROUNDING CONNECTIONS c TO SCALE: NOT TO SCALE BOTHEENDS `� CASTLE 1505 WESAKE AVENUE NORTH,SC-ITl 800 SEAE,WA 98109 D (GREEN INSULATED) ONLY FOR #6 AWG I�ii�I/ `/TO ANTENNASART) WEATHERPROOFING KIT (SEE NOTE 3) (TYPICALLY) / v v \ 49030 Pontiac Trail,Suite 400 ANTENNA CABLE 12"TO 24" • 120" MAX RX2 TX1/RX1 WEATHERPROOFING Wixom,Michigan 48393 KIT PHONE:(248)705-9212 1 (TYP) NOTES: GROUND KIT 1. ALL GROUNDING LUGS ARE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. COAX JUMPER (TYP.) (TYP) ALL HARDWARE BOLTS, NUTS, LOCK WASHERS SHALL BE STAINLESS STEEL ALL VERIZON SITE NUMBER:307842 HARDWARE ARE TO BE AS FOLLOWS: BOLT, FLAT WASHER,GROUND BAR, GROUND LUG, I FLAT WASHER AND NUT. CONNECTOR 6 AWG TC,B WEATHERPROOFING KIT ®SCALE: MECHANICAL LUG CONNECTION #:874135 p6 AWG STRANDED COPPER GROUND WIRE I . (TYP. SEE NOTE 2) WEST PORTD NOT TO SCALE • (GROUNDED TO GROUND BAR). SEE NOTE 1 & 2 COPPER/GALVANIZED a c / COAX GROUND BAR I0955 SW 65TH AVE CABLE GROUND KIT j j j BONDED DIRECTLY TOWER TIGARD,OR 97223 CABLE CONNECTOR j EXISTING 94'-0"MONOPOLE ANTENNA CABLE- #6 AWG MIN. FROM ANTENNA NOTFS1 TO BTS EQUIPMENT (TYP.) CABLE GROUND KIT 1 I I I I 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND ISSUED FOR: WIRE DOWN TO GROUND BAR. NOTES' Hill REV DATE DAWN DESCRIPTION DES./QA 2. GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPUED OR A 04/26/202] RC PRELIMINARY PL RECOMMENDED BY CABLE MANUFACTURER. 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO ANTENNA GROUND BAR. GROUND BAR ON SHELTER. ICE 1111 , " " " ' o o7/s/2o21 RC FINAL. PL 3. WEATHER PROOFING SHALL BE TWO-PART TAPE KIT, COLD SHRINK SHALL NOT BRIDGE, OR ON ANTENNA TOWER BE USED. 2. WEATHER PROOFING SHALL BE TWO-PART TAPE KIT. COLD SHRINK SHALL NOT BE °CABLE GROUND KIT CONNECTION USED. SCALE: NOT TO SCALE 000E- iO�OO � O4 GROUND CABLE CONNECTIONa --O, -0 °SCALE: NOT TO SCALE 0 3/8-11x1"TAMPER ---fi .TWO HOLE LUG, OR ' ' GROUNDING SHALL BE RESISTANT BOLT / EXOTHERMIC WELD TO BE USED ELIMINATED WHEN GROUND BAR ® WITH GROUND ORRG OOUNDU RING ' ' IS ELECTRICALLY BONDED TO � � WIRE TOG BABUILDE ING SERVICE METAL TOWER P.INSULATORS PKIIIR i SEE NOT ) 1 iky Old *TCIIA1 fey* WALL bro BRACKET `/ •GROUNDWIRE INSTALLATION wag BIAOMI�.D H ( ) �� 0 O 0 NOT MINIMUM OF TO BE S/S NUT (Di NOT TO SCALE �� VISIBLE (TYP) Mi 0 r o (TYP) > 6r7s ill 0 1 WASHERS/S SPLIT '� 0 0 BARRELOL TINNED LONG '\ ( ) #2 TINNED SCUD IN 3/4" LIQUID TIGHT PIPE OF 00 UNIVERSAL COPPER SOLID COPPER \ CONDUIT FROM 24" BELOW GRADE TO \� 0 GROUND BAR (4"x20' LUG S/S FLAT WITHIN 3"TO 6" OF CAD-WELD LOCK WASHER SO °� WASHER TERMINATION POINT. EXPOSED END OF P/N M1O ( )to (TYP) THE LIQUID TIGHT CONDUIT MUST BE (TYP) SEALED WITH SILICONE CAULK. TWO-HOLE COMPRESSION LUG TIN COATED SOUD � � CADWELD --- NOTES: COPPER BUS BAR �— S/S FLAT ) N. 1. DOWN LEAD (HOME RUN) CONDUCTORS ARE NOT TO BE INSTALLED ON CROWN CASTLE WASHER 11 USA INC. TOWER, PER THE GROUNDING DOWN CONDUCTOR POLICY OAS-STD-10091. NO CHERRY INSULATOR ) - IT IS:\11OL.i1TON OF LAW FOR ANY PERSON, MODIFICATION OR DRIWNG TO TOWER STEEL IS ALLOWED IN ANY FORM OR FASHION, INSTALLED IF REQUIRED S/S BOLT UNLESS THEYAREACTINGUNDERT-IEDIRECTION CAD—WELDING ON THE TOWER AND/OR IN THE AR ARE NOT PERMITTED. O TIE INTO EXISTING GROUND RING --� of LICENSED PROEESS1oN.j7.EVGINEER, TO ALTERTIIIS DOCUME_Nt- 2. OMIT INSULATOR WHEN MOUNTING TO TOWER STEEL OR PLATFORM SILLL USE INSULATORS WHEN ATTACHING TO BUILDING OR SHELTERS. SHEET NUMBER: ` REVISION: ©SCA GROUND NOT TO SCALE ®LUG SCALE: NO DETAIL T TO SCALE ®SCALE:I NOT TO SCALE GROUND DETAIL 1i - 2 O