Loading...
Plans PARTITION KEYED NOTES O SITE SPECIFIC SCOPE NOTES: 30 i' ) o a:).-- u p J .t - 1. PHONE COMPANY SERVICE TO BE INSTALLED AT BOC LOCATION PER DETAIL ON GENERAL CONDITIONS SHEET 8 OF 8 AND PER SPECIFICATIONS ON 1ST DAY OF CONSTRUCTION. EMAIL 1. SPACE TO BE DELIVERED IN AS-IS CONDITION. P v"si \ 12 7 ? �J CN PHOTO TO LEASING COORDINATOR TO CONFIRM WORK ASAP. 2. ALL ITEMS TO BE COMPLETED PER EDWARD JONES SPECIFICATIONS,SEE SHEETS 6-8 UNLESS b OTHERWISE NOTED.PLEASE NOTE:SITE SPECIFIC NOTES ON SHEETS 1-5 ARE TO SUPERCEDE GENERAL SPECIFICATIONS ON SHEETS 6-8 UNLESS BUILDING STANDARD APPLIES. 2. INSTALL DOOR CHIME AT ENTRY DOOR.CHIME TO BE LOCATED IN 101. HEATH 3. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS&WINDOW MULLION PLACEMENT PRIOR TO ZENITH WIRELESS DOOR ALERT WITH WHITE COVER&HORIZONTAL LINES-HOME CONSTRUCTION;IF UNABLE TO VERIFY DIMENSIONS OR IF A DISCREPANCY OCCURS,NOTIFY DEPOT MODEL#SL-7368-02 OR COMPARABLE ALTERNATIVE. DESIGNER IMMEDIATELY. 4. VERIFY LOCATION OF ALL EXISTING DEMISING PARTITIONS.VERIFY THEY EXTEND TO THE DECK& • 30-10" 3. IF LOCAL CODE WILL NOT ALLOW FOR THUMB-TURN LOCKSET AT ENTRY DOOR, ARE INSULATED;EXTEND&ADD INSULATION AS REQUIRED. NOTIFY DESIGNER IMMEDIATELY WITH ALTERNATIVE OPTIONS FOR LOCKSETS SITE WORK iv-1" 4'-0" 14'-11^ 1. REFERENCE SHEET 2 FOR ALL DEMOLITION RELATED SCOPE OF WORK. A, ix WITH INTERIOR LOCKING MECHANISMS. 2. EXISTING BLINDS TO REMAIN;PROTECT DURING CONSTRUCTION. - -- � � Ir' ��- 4. INSTALL TWO QUAD ELECTRICAL OUTLETS&TWO DATA BOXES WITH PULL CONCRETELu 1. ENSURE ALL FLOORING SURFACES ARE CLEAN,DRY,SMOOTH,&LEVEL WITHIN 3/16"PER EVERY z z 1 UI STRING FOR FUTURE AUDIONISUAL DISPLAY AT 66"AFF&18"AAF HEIGHT. 10 FEET;READY TO ACCEPT NEW FINISHES PER FINISH SCHEDULE. cr EQUIP! / CD E u PROVIDE BLOCKING AS REQUIRED FOR TV MOUNT. FA TO PURCHASE TV&TV THERMAL&MOISTURE PROTECTION w .�. SUPP. WALL MOUNT. 1. INSTALL 4FT LAY-IN BATT INSULATION ABOVE DROP CEILING AT ROOM 102A AND 102B. 4 44I 104 DOORS(AND WINDOWS1 N co a o OFFICE E N OPEN 1. EXISTING DOORS TO REMAIN;INSTALL NEW 3'-0"SOLID CORE DOORS TO MATCH EXISTING ENTRY Z N „..; .i, 3), 11p2A ,6,,‘., „ , 106 DOOR IN 102B.STAIN DOORS AND TRIM TO MATCH EXISTING. t Z cn E 6•z 1 - 2. INSTALL BI-FOLD DOOR TO MATCH EXISTING DOOR STAIN IN 104. u. Q -, 3. RELOCATED EXISTING DOORS AS SHOWN ON PLAN;SALVAGE TRIM AND/OR PROVIDE NEW TO C z TV MOUNT MATCH EXISTING AS NEEDED. Ca w Cn w UJ 4. NO DOOR CLOSERS TO BE INSTALLED ON INTERIOR DOORS UNLESS OTHERWISE NOTED;EXISTING J �_ ,- 0 E i O DOOR CLOSERS ON INTERIOR DOORS TO BE REMOVED IF IN PLACE. Q w w 0 q E FINISHES (� w Q o ,,,,„„�{„„ 7,, �,. 1• . EXISTING CEILING TO REMAIN;PATCH/REPAIR AS REQUIRED.ENSURE CONSISTENT GRID N > < 0 THROUGHOUT SPACE. 6'-p" 1 1r-11^ p = o} I- 2. CLEAN LENSES AND REPLACE ALL STAINED/DAMAGED CEILING TILES. Z c u. z PASSAGE � E - 3. PATCH,REPAIR,&PREP EXISTING PARTITIONS AS REQUIRED FOR NEW FINISHES.MATCH EXISTING O vi 0 1 103 I TEXTURE ON NEW PARTITIONS. 0 ixz in t 0 4. INSTALL NEW FLOORING PER FINISH SCHEDULE ON SHEET 4.REFER TO FINISH PLAN FOR .*x 0 - Q M 1 OFFICE E, PATTERN INSTALL DIRECTION. v COII102B1 E : e MECHANICAL o a 1 - 1. INSTALL/RELOCATE SUPPLY&RETURN GRILLES,INCLUDING DUCTWORK,AS REQUIRED FOR z w -�' V COMPLETE&BALANCED WORKING SYSTEM AND TO ACHIEVE ONE SUPPLY&ONE RETURN AT 0 F_ w MINIMUM IN EACH ROOM. v w m 2. CLEAN&CHECK EXISTING HVAC UNIT. 0 3. PROVIDE&INSTALL DIGITAL PROGRAMMABLE THERMOSTAT IN PASSAGE 103. >- """"" "1.,u' """" 4. MODIFY EXISTING SPRINKLER SYSTEM/SMOKE DETECTORS/FIRE ALARMS AS REQUIRED BY LY ' © w } LOCAL CODES. E 5. PROVIDE AND INSTALL FIRE EXTINGUISHER IN BRANCH AS REQUIRED BY LOCAL CODES. w co EDJ LOGO ELECTRICAL zcm 1. BRANCH TO BE LOW VOLTAGE PREWIRED PER LOCAL CODES. 00 4 2. VERIFY EXISTING ELECTRICAL PANEL MEETS EDJ SPECIFICATIONS;UPGRADE OR ADD SUB-PANEL m � W BOA AS REQUIRED.EP IS LOCATED IN A COMMON AREA,INSTALL BREAKER LOCKS AS REQUIRED. w CC I- 101 3. INSTALL NEW ELECTRICAL PER PLAN UNLESS WITHIN 36"OF EXISTING RECEPTACLE;ALL a 0 00 ELECTRICAL TO REMAIN AS SHOWN AT FA AND BOA DESK LOCATIONS. D �S o Li. 4. REPLACE EXISTING SWITCHES,OUTLETS,AND FACE PLATES WITH WHITE;NEW SWITCHES, c) m Z w OUTLETS,AND FACE PLATES TO BE WHITE. r- w I- Q E 5. EXISTING LIGHTING TO REMAIN THROUGHOUT.INSTALL ADDITIONAL AND RELOCATE EXISTING co co p t- oO a 10'x4'LIGHT FIXTURES ACCORDING TO NEW PARTITIONS;ONE FIXTURE PER EVERY 75 USABLE SF, w u) a co O2 SO AS TO ACCOMMODATE MINIMUM 50 FOOTCANDLES AT DESK LOCATIONS. O 6. INSTALL COMMERCIAL WALL WASH LIGHT FIXTURE TO ILLUMINATE INTERIOR LOGO AS PER KEYNOTE P2 ON SHEET 4;TO BE SEPARATELY SWITCHED. y E. r---- W COMMON RESTROOMS O W coo ti r-, U' ED PARTITION PLAN , r WZ c < **BRANCH TO BE LOW-VOLTAGE PREWIRED PLAN ISSUES I REVISIONS EXHIBIT A NORTH NO. I DATE I DESCRIPTION 4) PARTITION PLAN SHEET 3 3 of 8 FINISH KEYED NOTES WALL TO BE PAINTED WITH ACCENT COLOR,SEE FINISH SPECIFICATIONS FOR ACCENT WALL COLOR CODE. WALL TO BE PAINTED WITH ACCENT COLOR P2,AND EDJ LOGO INSTALLED PER SPECIFICATIONS BELOW... EDJ LOGO(LETTER KIT W/PINS ON BACK) 1. PROVIDE&INSTALL COMMERCIAL LINEAR SLOT WALL WASH LIGHT(SEE SPECIFICATIONS SHEET 7),TO BE INSTALLED IN CEILING 3'-0"AWAY FROM WALL AND CENTERED ON PARTITION. 2. SIGNAGE TO BE ORDERED BY CONTRACTOR AND WILL BE PAID FOR BY EDWARD JONES. ONLY THE INSTALLATION SHOULD BE INCLUDED IN SCOPE OF WORK. 3. EDWARD JONES LOGO TO BE CENTERED ON PARTITION AS INDICATED ON PLAN.USE PROVIDED TEMPLATE FOR ACCURATE ALIGNMENT,AND REFER TO SIGNAGE ELEVATION FOR MOUNTING HEIGHT.ALLOW AT LEAST 2"ON EITHER SIDE OF SIGNAGE;IF PARTITION SELECTED DOES NOT MATCH ELEVATION,NOTIFY DESIGNER. 4. CUSTOM EDJ FRY REGLET WALL REVEAL(EDJ-625-625)TO BE PURCHASED AND INSTALLED BY CONTRACTOR PER MANUFACTURER INSTALL INSTRUCTIONS;SEE SPECIFICATIONS SHEET 8 FOR DETAILS. **FOR ORDERING&INSTALL INSTRUCTIONS,SEE CONTACT INFO ON SHEET 1 w —1 j z o ROOM FINISH SCHEDULE W EQUIP! RM.NO. PAINT ACCENT FLOORING BASE DOOR TRIM CEILING NOTES a _-- c -- . lsuo - 101 P1 P2 LVT1 B1 EXIST EXIST DROP SEE NOTE'P2' wa102A P1 Al CPT3 B1 EXIST EXIST DROP SEENOTEAxzv■ EN,,,, T,=:; tos i 102B P1 Al CPT3 B1 MATCH MATCH DROP SEE NOTE'Ax' o Z u, 103 P1 LVT1 B1 DROP g z ik 104 P1 CPT3 B1 MATCH MATCH DROP w u"�i z _ __ _ _ 106 P1 Al CPT1 B1 EXIST EXIST DROP SEE NOTE I u w w P N » � - 1 :-•` i-- w z °- O z co — p PASSAGE FLOOR FINISH KEY FINISH SPECIFICATIONS i SECURE PALETTE 0 ui w �, EXIST=EXISTING FINISH TO REMAIN PAINT FLOORING * o1 w OFFICE MATCH=NEW FINISH TO MATCH EXISTING v * cti i GENERAL WALL PAINT GENERAL CARPET TILE o 1 ;' _ .,•__:_ ; ,.,.t;" N.I.C.=NOT IN CONTRACT FOR FINISHES P1 CPT3 ,� MFR: SHERWIN WILLIAMS MFR: INTERFACE z a w N/A=NOT APPLICABLE TO THIS ROOM 4.., COLOR: SW 7005 PURE WHITE STYLE:EJ BOUCLE op x • CARPET TILE FLOOR S 25CM X13 __ `•_- - -_ - -- - - - -� ��:-- P2 BRAND WALL PAINT SIZE: 1M PATTERN MFR: SHERWIN WILLIAMS INSTALL:ASHLAR >.. >- LUXURY VINYL TILE DIRECTION COLOR: SW 7075 WEB GRAY w LUXURY VINYL TILE co EXISTING TO REMAIN / A3 ACCENT WALL PAINT LVT1 MFR: INTERFACE z MFR: SHERWIN WILLIAMS STYLE:STUDIO SET 'v NOT IN CONTRACT / COLOR: SW 6524 COMMODORE COLOR:A00704 ESPRESSO m SIZE:25CM X 1M w ct < BOA iou SIGNAGE ELEVATION INSTALL:STAGGERED PLANK 0 0 _z w __ w I • ali a cc o — c_ WALL BASE Er co VINYL WALL BASE w I.u1\\,1ra1D0WC��N 61 MFR: ROPPE th H I -. STYLE:4"COVE BASE O F-• r— T Z COLOR: 194 BURNT UMBER = w il O H GENERAL NOTES: w w N cFINISH PLAN 1. REFER TO FINISH SPECIFICATIONS ON SHEETS 6-8 FOR MORE INFORMATION N 1/8" = 1 1_0" ` ` ` REGARDING PAINT FINISH. Z o 0 2. GC TO NOTE BRANCHES COULD HAVE MULTIPLE ACCENT COLORS, REFER TO `-.) PLAN AND SCHEDULE FOR LOCATIONS AND PAINT COLORS INDICATED. d Li; REFER TO KEYED NOTE ABOVE 3. GC TO LEAVE 1 CARTON OF CARPET TILE @ BRANCH AT PROJECT COMPLETION. w m co o PL40 4AN GENERAL NOTES: ISSUES I REVISIONS EXHIBIT A NORTH 1. LOGO TO BE CENTERED ON WALL UNLESS NO. I DATE I DESCRIPTION OTHERWISE INDICATED. FINISH PLAN 2. WALL REVEAL AVAILABLE IN 10'-0" STANDARD LENGTHS ONLY.WALLS SHEET A LONGER THAN 10'-0"WILL HAVE A SEAM. L� of 8 EQUIPMENT LEGEND **EQUIPMENT SUPPLIED&INSTALLED BY EDWARD JONES r, MONITOR ARMS LASER PRINTER BOC(BRANCH OFFICE CONTROLLER) PHONE SYSTEM* COPIER/FAX/SCANNER —a1 � --- _1 STANDARD FURNITURE !; - 4-eQutPi suPP. E 0. GENERAL NOTES lib D 1. REFER TO PLAN FOR EXACT CONFIGURATION AND HANDEDNESS OF FURNITURE OFFICE E OPEN TO BE PROVIDED. HANDEDNESS CANNOT BE INTERCHANGED ONCE ORDER IS 4 11O2Aj ,«„_ 1106 I PLACED. CONFIRM HANDEDNESS WITH DESIGNER PRIOR TO ORDER. z .1* E 2. EXACT ORDER TO BE VERIFIED WITH DESIGNER PRIOR TO PURCHASE. fx 3. ONCE ORDER IS PLACED,ANY CHANGES WILL RESULT IN ADDITIONAL CHARGES. _ 4. REFER TO PLAN FOR EXACT LOCATION OF WALL-MOUNTED ACCESSORIES, to _ a Eb. 5. REFER TO MANUFACTURER SPECS FOR WALL MOUNTED ACCESSORY HEIGHTS Z 1-- >- to r 0 BOA WORKSTATION o < -3 g � z r- 42"TRANSACTION 0 W cA W PASSAGE E ..,./ HEIGHT-ADJUSTABLE LU cp Z 103 ( 33'TRANSACTION Ui = O J O OFFICE 0 Q ID 10, 1026 I E 4. , U) W. = I- 4 . . 4411P1 ('" 0 2 >- I__ r__,.. 0 lire A -I> 0 co al in ACl o O- ' v)v E- - REFER TO PLAN FOR EXACT CONFIGURATION AND HANDEDNESS,LEGEND FOR REFERENCE ONLY Z WO W e+) EDJ LOGO O 1- W is, FA DESK GUEST CHAIRS . w u a BOA R I101 lr I L}I iX LU v N ` (n i w Z Ni v IMIN4140 I"ri\ 0 cN cN r . CD u.I CC IF HEIGHT- d O O ADJUSTABLE �- c 0 i -9 AXON VIEW co M cc COMMON RESTROOMS M H cr REFER TO PLAN FOR EXACT CONFIGURATION,HANDEDNESS,AND S ci = O CY ACCESSORY LOCATIONS,LEGEND FOR REFERENCE ONLY ,- CC CO O_ CO FINISHES E in O FURNITURE / EDJ EQUIP. PLAN E� 1/8 = r Is 1 0 = t£;txs - ; _ ce��, , � 0 w ;3 Ir. !..ft *-z= w Lu gg`- a04 i C x p m il Z (2)DESK/FRAMES HASHTAG Q Z di UPHOLSTERY ;.T. m PLAN ISSUES I REVISIONS EXHIBIT A NORTH NO. I DATE I DESCRIPTION FURNITURE/EDJ EQUIPMENT PLAN SHEET 5 of 8 EDWARD JONES GENERAL BUILDING AND FINISH SPECIFICATIONS GENERAL NOTES 3. FINISH DEMISING WALL ON BOTH SIDES ONLY IF REQUIRED BY CODE,OR IF NOTED OTHERWISE EDJ PLUMBING FIXTURE SCHEDULE ON PLANS.IT IS CONTRACTOR'S RESPONSIBILITY TO CONFIRM IF THIS IS REQUIRED DURING THE ITEM MODEL-# COMMENTS 1. THE FOLLOWING INFORMATION IS PROVIDED AS A GENERAL GUIDE.IN ALL CASES,IT IS PREFERRED BIDDING PROCESS. 18"GRAB BAR BOBRICK#B 5806X18 THAT THE BUILDING STANDARD BE USED;OTHERWISE,USE THE INFORMATION PROVIDED BELOW AND ! d. A MINIMUM OF 3"SOUND BATT INSULATION SHALL BE INSTALLED IN PARTITIONS AS INDICATED ON ON THE DESIGN INTENT DRAWINGS,OFTEN REFERRED TO AS EXHIBIT A. IT IS THE INTENT THAT THESE EXHIBIT A BETWEEN STUDS AND ABOVE CEILING WHERE THE WALL AND CEILING MEET. IF WALLS 36"GRAB BAR BOBRICK#B-5806X36 MODIFICATIONS/ADDITIONS/IMPROVEMENTS WILL BE PERFORMED ON AN"AS NEEDED"BASIS,AT THE ARE EXISTING,USE BLOW-IN INSULATION. 42"GRAB BAR BOBRICK#B-5806X42 REASONABLE DISCRETION OF EDWARD D.JONES&CO.,L.P.D/B/A EDWARD JONES,HEREIN AFTER e. PROVIDE RUBBER MOLD/BREAK METAL AT WINDOW MULLION,CAULK ALL SEAMS. ALL WALLS THAT MIRROR` 24"WX36"H W/J-MOLD REFERRED TO AS EDWARD JONES OR TENANT. END AT EXTERIOR WALLS OR MULLIONS TO INCLUDE SOUND CAULK AND RUBBER GASKET AT POINT PAPER TOWEL 47260-SCOTT MODTM ELECTRONIC SLIMROLL,BLACK,PINK 2. ANY DISCREPANCIES ON SHEETS 1-5 TO BE BROUGHT TO DESIGNERS ATTENTION IMMEDIATELY. OF CONNECTION. DISPENSER CODE 3. ALL WORK SHOULD BE PERFORMED BY G.C.(GENERAL CONTRACTOR)PER CITY,STATE,PROVINCIAL, SINK FAUCET Z7440-XL FAUCET AND NATIONAL CODES(ALL REFERENCES TO"CODE"IN THIS DOCUMENT TO APPLY TO CITY,STATE, 3. CEILING(UNLESS BUILDING STANDARD APPLIES) PROVINCIAL,AND/OR NATIONAL CODES AS APPLICABLE).ALL CONSTRUCTION WILL BE COMPLETED SO a. CEILINGS TO BE FREE FROM STAINS AND DIRT. IF INSTALLING NEW,PROVIDE AND INSTALL 2 X 4' SINK** ZURN#5340,WHITE ADA-COMPLIANT WALL MOUNTED, THAT AN OCCUPANCY PERMIT(OBTAINED BY THE G.C.)WILL BE GRANTED PRIOR TO LEASE COMMERCIAL GRADE GRID AND OLYMPIA MICRO 60 ACOUSTICAL CEILING TILES OR COMPARABLE CAULK AS REQ. COMMENCEMENT. SPEC. MATCH BUILDING STANDARD WHERE APPLICABLE.STANDARD HEIGHT FOR NEW CEILING TO SOAP 32504 SCOTT MOD WALL MOUNTED,TOUCHLESS 4. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST ISSUED EDITION OF THE EDWARD BE 9'-0", UNLESS NOTED ON PLANS. DISPENSER SKINCARE DISPENSER BATTERY OPERATED I JONES APPROVED EXHIBIT A INCLUDED WITH THE CONTRACT FOR SERVICES AT TIME OF BID AWARD. b. ACOUSTICAL CEILINGS: TILES TO BE FREE FROM CHIPS AND BREAKS;ALL TILES TO BE SAME TOILET PAPER 09604 SCOTT SERIES SURFACE MOUNTED DOUBLE ROLL w w 5. EXHIBIT A IS INTENDED FOR DESIGN INTENT ONLY AND IS NOT AN OFFICIAL CONSTRUCTION COLOR AND STYLE;GRID TO BE WHITE AND EVEN,FREE FROM HOLES(OR FILLED),AND SHOULD BE DISPENSER INSIGHT TOILET TISSUE DISPENSER cn Q Z DOCUMENT. GENERAL CONTRACTOR(GC)TO OBTAIN ALL NECESSARY PERMIT DRAWINGS AS CLEAN.PAINT WHITE IF EXISTING IS IN POOR CONDITION OR A COLOR OTHER THAN WHITE. TOILET PLASTIC ACCESSIBLE 4, I=- a_ w REQUIRED PER CODE;COST TO BE INCLUDED IN BID IF REQUIRED TO OBTAIN PERMITS. REPLACE AS REQUIRED. TILES SHOULD BE A STANDARD COMMERCIAL GRADE ACOUSTICAL TILE. SIGNAGE RESTROOM SIGN-UNISEX to o Q J 6. GENERAL CONTRACTOR MUST PROVIDE ALL SUBCONTRACTORS ALL 8 SHEETS AT TIME OF BID AND/OR CONTIGUOUS AREAS MUST HAVE MATCHING TILE. TOILET** PF5112HEWHlPF1403TWH ADA COMPLIANT,FLOOR MOUNTED 0 u z a PRIOR TO ANY CONSTRUCTION. c. DRYWALL CEILINGS:TO BE LEVEL,HAVE AN EVEN TEXTURE(MATCH EXISTING WHERE APPLICABLE), W C v (LEFT FLUSH) CAULK AS REQ. 'S cn 7. ALL EXISTING ITEMS TO REMAIN IN BRANCH(AS SHOWN ON PLANS)MUST BE IN GOOD WORKING AND BE PAINTED WHITE(SEE PAINT SPEC). Q Q w PF5112RHEWH/PF1403TWH ce a -f co w ORDER AND CONDITION,AND FREE OF MAJOR DEFECTS. (RIGHT FLUSH) -' 8. EDWARD JONES'INSTALLERS MUST BE NOTIFIED OF ANY CHANGES IN PLACEMENT OF EQUIPMENT, 4. FIRE PROTECTION w coOD Q cK PHONES,OUTLETS,OR FURNITURE.EDWARD JONES HAS AN ESTABLISHED RELATIONSHIP WITH a. PROVIDE AND INSTALL NEW SPRINKLER SYSTEM ONLY AS REQUIRED BY CODE. IF EXISTING, ITEMS SHOWN WITH ** —A > z NATIONAL VENDORS FOR FLOORING,PAINT, SIGNAGE,AND LOW VOLTAGE WIRING. MODIFY SPRINKLER LAYOUT AS REQUIRED PER CODE. INCLUDE NECESSARY PERMITS AND MAY USE SIMILAR 0 = >- 9. FURNITURE,EQUIPMENT,BOTTLED WATER COOLER(IF REQUIRED BY CODE),PHONE AND DATA WIRING INSPECTIONS. HEADS MUST BE CENTERED IN TILE. ALTERNATE MODEL, Cl) W CI &ALL TERMINATIONS TO BE PROVIDED BY THE TENANT. b. PROVIDE APPROPRIATE COVERAGE OF HEADS FOR PARTITION LAYOUT AS REQUIRED BY CODE PER °iJ OTHERWISE GC TO 10.THE SPACE SHOULD BE CLEANED AFTER CONSTRUCTION. PARTITION LAYOUT AS SHOWN ON EXHIBIT A. QUANTITY AND LOCATION OF HEAD TO COMPLY WITH I IL �L USE SPECIFIED ITEM. Z Ir z ¢ M ti 11.WARRANTY DOCUMENTS SHALL BE PROVIDED TO THE BRANCH REAL ESTATE ONCE CONSTRUCTION IS APPLICABLE CODES. I Z p oo z "fPLAN CLEARANCE O p COMPLETE. c. PROVIDE/MODIFY FIRE ALARM SYSTEM IF REQUIRED BY LOCAL CODE. ' FLUSH 0 U AT WATER CLOSETS qW o U 12. UPON PROJECT COMPLETION,CLOSE OUT DOCUMENTS TO BE SUBMITTED WITH FINAL INVOICE d. PROVIDE DESCRIPTION OF ANY LIFE SAFETY SYSTEM PROVIDED IN BUILDING AND ITS OPERATION. CONTROL ON I I- u- M INCLUDE:CONSTRUCTION DOCUMENTS,APPROVED CHANGE ORDERS,CERTIFICATE OF OCCUPANCY, e. PROVIDE AND INSTALL SMOKE DETECTORS AS REQUIRED BY CODE. OPEN SIDE J zo 1- w LIEN WAIVER, FINAL PHOTOS OF SPACE,COMPLETED PUNCH LIST WITH ALL OUTSTANDING ITEMS f. PROVIDE AND INSTALL FIRE EXTINGUISHER;TO MEET ALL LOCAL CODES. «o Cr)W a COMPLETED,AND AN AIR BALANCE REPORT. 56"MIN.(Wall Mounted) 5. TOILETIWASHROOM&PLUMBING(UNLESS COMMON FACILITIES PRESENT) 59"MIN.(Floor Mounted) CC INTERIOR CONSTRUCTION SPECIFICATIONS a. PROVIDE AND INSTALL RESTROOM LAYOUT AND FIXTURES AS SHOWN ON EXHIBIT A. WASHROOM w TO BE BARRIER FREE/HANDICAP ACCESSIBLE AS REQUIRED BY CODE AND AS SHOWN ON PLANS. 54"MIN ....t... V/ .- CO 1. DEMOLITION G.C.TO ADHERE TO ANY CODES,WHICH MIGHT REQUIRE MODIFICATION OF EXISTING RESTROOM 39"-41" W Iva a. DEMOLISH AND REMOVE FROM THE SITE ALL DEBRIS FROM THE AREAS AS SHOWN ON EXHIBIT A. NOT SHOWN ON PLANS;CONTACT DESIGNER IF CODE REQUIREMENTS DIFFER FROM PLANS. 36"MIN. � LEAVE SPACE FREE OF ALL CONSTRUCTION DEBRIS. b. RESTROOM TO HAVE(1)OF EACH OF THE FOLLOWING:TOILET,SINK,WATER HEATER(DEDICATED MEM CNJ n co b. REMOVE EXISTING FINISHES ONLY IN AREAS THAT ARE TO RECEIVE NEW FINISHES PER THE FINISH TO EDJ SPACE),GRAB BARS,TOILET PAPER HOLDER,PAPER TOWEL DISPENSER,SOAP DISPENSER -,..._ a o 1-- SCHEDULE SHOWN ON SHEET 4.ROOMS LISTED"NIC"OR"EXIST"SHALL REMAIN AS-IS UNLESS AND MIRROR. PROVIDE AND INSTALL ANY OTHER ACCESSORY AS NOTED ON PLANS OR REQUIRED a O OTHERWISE NOTED ON FLOOR PLAN. BY CODE. "Iel Z. ri " z w c. LEAVE AND/OR PREPARE FLOOR TO ACCEPT NEW GLUE DOWN FLOORING PER FINISH SCHEDULE. c. EXISTING RESTROOM/WASHROOM FIXTURES TO REMAIN TO BE IN GOOD CONDITION(I.E.IN GOOD M 7"-9" M M ::::L2" "'SURFACES THAT ARE TO ACCEPT NEW FLOORING ARE TO BE FREE OF ALL DEBRIS AND/OR OPERATION AND FREE OF STAINS OR CRACKS).CLEAN AND RESET FIXTURES AS REQUIRED. `-. --'--' o o o 0 RESINOUS DEPOSITS.FOR BRANCHES ON A SLAB FILL ALL FLOOR CUTS REMAINING FROM ANY d. SINK(S)(ONLY IF SHOWN ON EXHIBIT A)TO HAVE HOT AND COLD-WATER SERVICE. IF UNABLE TO 42"MIN (-12"MAX. IX cn a. CO PLUMBING OR OTHER TERMINATION WITH CONCRETE.DEMO ALL FLOOR OUTLETS AND PATCH AS INSTALL WATER HEATER ABOVE CEILING,INSTALL INSTA-HOT UNDER SINK. REAR WALL GRAB BAR DISPENSER LOCATION SIDE WALL GRAB BAR REQUIRED. IF FLOOR HVAC VENTS ARE PRESENT IN A WALKWAY,PLEASE CONTACT DESIGNER FOR e. PROVIDE AND INSTALL EXHAUST FAN WITH ADEQUATE DUCTING AND SEPARATELY SWITCHED AS AT WATER CLOSETS AT WATER CLOSETS/SEAT HEIGHT y RELOCATION INSTRUCTIONS. REQUIRED. • F-, f. PROVIDE AND INSTALL BARRIER-FREE UNDER-SINK PIPE PROTECTIVE COVER UNDER SINK IN 105. = w 33 2. PARTITIONS Q a. ALL NEW WALLS WILL BE CONSTRUCTED OF 3 5/8"METAL STUDS AT 16"O.C.(WOOD STUDS mmil `4 PAPER TOWEL DISPENSER d ACCEPTABLE IF APPROVED BY CODE)AND 5/8"DRYWALL MINIMUM,OR MATCH EXISTING TO REMAIN. **IF ABOVE COUNTER, b. ALL NEW AND EXISTING WALLS SHALL BE TAPED AND SMOOTH,READY FOR PAINT,LEVEL 5 FINISH. TO BE MOUNTED 12" F"+ I� ry c. ALL DEMISING WALLS TO BE BUILT TO DECK STRUCTURE ABOVE,FIRE SEALING ALL PENETRATIONS TACTILE AND BRAILLE ROOM ID SIGNAGE,ANSI A117.1& MIRROR FROM BOTTOM OF • IN DISPENSER•• 0 c;AS REQUIRED.IF PROPERTY UTILIZES A PLENUM RETURN FOR ENTIRE BUILDING,IT IS REQUIRED TO 1 1/3232".C.ALL UPPER CASE TEXT 5/8"-2"HEIGHT,RAISED Z 4 _ CHARACTERS SHALL BE SAN SERIF CONTRACTED U TAKE DEMISING WALLS TO HEIGHT OF ADJACENT TENANT'S WALLS AND INSTALL SECURITY O 30 GRADE 2 BRAILLE,703,3.4&11B-703.3.MINIMUM O 1111 - LEVER SOAP DISPENSER Z Lii FENCING FROM TOP OF WALL TO DECK TO PROVIDE A SECURE DEMISING WALL. Z CHARACTER HEIGHT SHALL COMPLY WITH TABLE 2 z I CONTROLS FAUCET !;,,,.� **IF ABOVE COUNTER, w C>~ CO ao 703.2.4&11B-703.5.5. g g Y TO BE MOUNTED 10" Q] 1. VERIFY DEMISING WALLS ARE INSULATED AND EXTEND TO DECK;EXTEND AND PROVIDE _ o - g = FROM BOTTOM OF INSULATION AS REQUIRED Nr M " 18"MIN. WALL I,_�\ RESTROOM IDENTIFICATION COLORS TO �`U DISPENSER** 2; PROVIDE AND INSTALL SOUND BATT INSULATION ABOVE CEILING ALONG NEW DEMISING IIIII CONTRAST WITH DOOR COLOR.NO BRAILLE. FINISH PARTITION.IF ADJACENT TENANT IS A RESTAURANT OR NAIL SALON,CAULK ALL OUTLETS AND UNISEX SIGN TO INCLUDE 12"DIAMETER LAVATORY FLOORLINE CONTRASTING COLORS. MOUNTING HEIGHTS AND WALL ACCESSORY SPECIFICATIONS PENETRATIONS AS WELL AS FLOOR LINE AND CONNECTION AT DECK TO AVOID SMELL CLEARANCE MOUNTING HEIGHTS TRANSFERENCE. II SHEET 1 6 of 8 EDWARD JONES GENERAL BUILDING AND FINISH SPECIFICATIONS 6. HVAC(UNLESS SHARED SYSTEM PRESENT) 8. DOORS(UNLESS BUILDING STANDARD APPLIES;SEE SHEET 3 FOR PAINTISTAIN INSTRUCTIONS. 10. PAINT a. SYSTEM TO BE FULLY OPERATIONAL,IN GOOD CONDITION AND PROPERLY BALANCED UPON a. DOORS(BOTH INTERIOR AND EXTERIOR)AND OTHER WOODWORK SHOULD BE STAINED OR PAINTED a. ALL EXPOSED SURFACES IN AREAS INDICATED IN FINISH SCHEDULE ON SHEET 4, COMPLETION OF WORK.BALANCE BOTH HEATING AND COOLING. SYSTEM TO BE DEDICATED TO TO MATCH EXISTING BUILDING STANDARD.IF NO STANDARD IS ESTABLISHED,USE PAINT OR STAIN SHALL BE PRIMED AND PAINTED WITH SHERWIN WILLIAMS PAINT. EDJ SPACE. AS LISTED IN THIS DOCUMENT.IF UNABLE TO OBTAIN DOOR BRAND AS SPECIFIED;SUBSTITUTE WITH b. FOR ALL REPAINT AND REMODEL,THE PRIME COATS NOTED BELOW MAY BE • HVAC BALANCE SHEET MUST BE SUBMITTED WITH INVOICE AT PROJECT COMPLETION. EQUAL&A LIKE PRODUCT.FINISHED DOOR WILL BE FREE FROM UNEVEN COLOR,DRIPS OR RUNS. EXCLUDED UNLESS COATING A BARE SURFACE. FOLLOW ALL MANUFACTURERS' b. ALL DUCTING, DIFFUSERS,GRILLES,AND THERMOSTATS SHALL BE CLEAN,IN GOOD CONDITION ALL DOOR EDGES,INCLUDING TOP AND BOTTOM,TO BE FINISHED. RECOMMENDED SURFACE PREPARATION. AND PROPERLY FUNCTIONING.LOCATION TO BE REVISED AS NECESSARY PER NEW PARTITION b. ALL DOORS TO BE INSTALLED CLEAR OF ANY OBSTRUCTIONS. c. ASSUME ONE TRIP FOR TOUCH UP PAINT AFTER FLOORING INSTALLATION AND LAYOUT.VERIFY THAT ALL ROOMS IN EDWARD JONES SPACE AS SHOWN ON SHEET 3/4/5 HAVE A c. ALL DOOR CLEARANCES TO BE MET AS SHOWN ON SHEET 3 AND PER ACCESSIBILITY FURNITURE DELIVERY. REMAINING TOUCH UP PAINT TO BE LEFT IN THE STORAGE - MINIMUM OF(1)RETURN AND(1)SUPPLY GRILLE AND MEET TEMPERATURE REQUIREMENTS TO REQUIREMENTS. AREA OF EDWARD JONES SPACE,CLEARLY LABELED. ENSURE A COMFORTABLE WORKING ENVIRONMENT. d. REUSE/RELOCATE EXISTING DOORS AS NOTED ON PLANS.ANY EXISTING DOORS BEING REUSED d. IF THERE ARE ANY QUESTIONS REGARDING PAINT COLORS,PLEASE CONTACT c. IF SPACE IS BEING SUBDIVIDED,EDWARD JONES SPACE TO BE SEPARATELY CONTROLLED-- SHALL BE TOUCHED UP AND REVARNISHED OR REPAINTED AS APPROPRIATE AND APPROVED FOR EDWARD JONES BRANCH DESIGN-DESIGNER NAME AND PHONE NUMBER LISTED SHARING OF THERMOSTAT WITH ADJACENT SPACES IS NOT ACCEPTABLE UNLESS IT IS AN OFFICE REUSE BY EDWARD JONES'DESIGNER.ANY NEW DOORS REQUIRED SHOULD MATCH EXISTING ON EXHIBIT A. BUILDING THAT UTILIZES A PLENUM RETURN.IF SHARED SYSTEM EXISTS,THERMOSTAT MAY NOT HEIGHT AND STYLE OF REUSED DOORS.DOORS CAN NOT BE UNDERCUT FOR ANY REASON.THE e. EXACT SPECIFICATIONS MAY BE OBTAINED FROM SHERWIN WILLIAMS: BE LOCATED WITHIN EDWARD JONES LEASED SPACE. MAXIMUM GAP ALLOWED IS W. 1-800-474-3794. d. VERIFY THERMOSTAT IS LOCATED IN AN ACCESSIBLE AREA OF THE SPACE AS SHOWN ON FLOOR e. ALL DOOR(S)TO HAVE WALL OR FLOOR MOUNTED STOPS,CONSISTENT WITH THE SPACE. f. REFER TO PAINT SELECTION SHEET 4.COLORS MAY INCLUDE SEVERAL,BUT NOT PLAN(TYPICALLY IN ROOM 101 OR 103). f. NO INTERIOR DOOR CLOSERS TO BE INSTALLED UNLESS OTHERWISE NOTED ON SHEET 3. ALL,OF THE FOLLOWING: w w e. PROVIDE AND INSTALL A NEW WHITE-RODGERS 7-DAY PROGRAMMABLE THERMOSTAT,UNLESS g. EXTERIOR DOORS: Cf, a z OTHERWISE NOTED ON PLANS. PROVIDE APPROPRIATE STAT FOR UNIT SIZE AND TYPE. SET 1. ALL DOOR(S)TO THE EXTERIOR AND BUILDING COMMON SPACES MUST HAVE CLOSERS AND GYPSUM PARTITIONS(EXCEPT ACCENT WALLS&CEILINGS): a Ce w THERMOSTAT FOR M-F 8-5 HOURS OF OPERATION. LEAVE INSTRUCTIONS TAPED TO THERMOSTAT DEADBOLTS WITH THUMB-TURN ON OCCUPIED SIDE. TWO FINISH COATS OVER AN EXISTING FINISH OR PRIMER. ce Z- a FOR FUTURE REFERENCE. A. IF CODE DOES NOT ALLOW DEADBOLT UTILIZE DEADLATCH. • SHERWIN WILLIAMS: Z o 0 f. HVAC SYSTEM SHOULD BE ABLE TO MAINTAIN 75 DEGREE F SUMMER AND 70 DEGREE F WINTER 2. AT REAR DOORS LEADING TO THE EXTERIOR,PROVIDE AND INSTALL INSULATED METAL DOOR • PRIMER:SHERWIN-WILLIAMS PROMAR 200 ZERO VOC,INTERIOR LATEX w z v TEMPERATURES IN ACCORDANCE WITH THE ASHRAE DESIGN STANDARDS APPLICABLE TO THIS WITH METAL PRY PLATES,CYLINDER GUARD,AT LEAST ONE SECURITY HINGE WITH NON- PRIMER,BS28W02600. Q ¢ w c2i> .LOCATION.IF NECESSARY,A FORMAL INSPECTION TO VERIFY EQUIPMENT CONDITION SHOULD BE REMOVABLE PIN(MCKINNEY TA2314 OR APPROVED EQUAL)AND PEEPHOLE INSTALLED AT 5'-0" • 1ST&2ND COATS:SHERWIN-WILLIAMS PROMAR 200 ZERO VOC fx a w Lu DONE. A.F.F. WHERE DEADBOLTS ARE NOT ALLOWED BY CODE,INSTALL PHOENIX DOUBLE DEFENDER EGGSHELL,A97-100 SERIES(IN ROLLER APPLICATIONS,USE ONLY A/z" w Q g. EDWARD JONES BOC(AS SHOWN ON EXHIBIT A)REQUIRES VENTILATION.INSTALL A SUPPLY QUICK RELEASE DOOR SECURITY BAR,SERIES DD-QR(UL LISTED PANIC HARDWARE 2N43).CALL NAP SYNTHETIC COVER). Q Q o= z GRILLE IN BOC ROOM(USUALLY ROOM 104)OR AREA IT IS LOCATED IN,TO MAINTAIN CONSTANT 913-723-3203 FOR LOCAL RETAILER. • COLOR:INDICATED ON SHEET 4 U = >- 0 TEMPERATURE REQUIRED. 3. SUITE ENTRY DOOR(S)SHALL HAVE EXISTING OPERABLE CLOSER(S)OR RECEIVE NEW Cl) 1- `i w h. IF BUILDING UTILIZES AN OPEN PELNUM SYSTEM, PROVIDE AND INSTALL SOUND BOOTS ON EACH CLOSER(S). INSTALL METAL PRY PLATES AT ALL TENANT ENTRY DOORS,COORDINATE WITH LLD GYPSUM PARTITIONS(ACCENT WALLS):(NOTE Ax,SHEET 4) ~O co ,r, RETURN GRILL(HERCULES INDUSTRIES SB222 SOUND BOOTS OR SIMILAR). PRIOR TO INSTALLATION. TWO FINISH COATS OVER AN EXISTING FINISH OR A PRIMER. Z w z ¢ M el 4. WASHINGTON/OREGON:INSTALL EXTERIOR DOOR LATCH PADDLE. • SHERWIN WILLIAMS: 0 oI- 1— 7. LIGHTING(UNLESS BUILDING STANDARD APPLIES) h. INTERIOR DOORS: • PRIMER: SHERWIN-WILLIAMS PROMAR 200 ZERO VOC,INTERIOR LATEX 0 t oS ,q a. IF T12 LIGHTING IS EXISTING UTILIZE BALLAST BYPASS LED LAMPS,PROVIDE AND INSTALL 1. NEW INTERIOR DOOR(S)TO BE NO LESS THAN 3'-0"W UNLESS NOTED OTHERWISE ON SHEET 3. PRIMER, BS28W02600. z o COMMERCIAL GRADE 2X4 LIGHT FIXTURES AT ONE FIXTURE PER EVERY 75 USABLE SF,SO AS TO 2. ALL NEW INTERIOR WOOD DOOR(S)SHOULD MATCH EXISTING WOOD DOOR HEIGHT AND STYLE, • 1ST&2ND COATS:SHERWIN-WILLIAMS COLOR ACCENTS INTERIOR o w J ACCOMMODATE MINIMUM 50 FOOTCANDLES AT DESK LOCATIONS. IF APPLICABLE. PROMAR 200 ZERO VOC EGGSHELL WALL FINISH,Y38 SERIES. . co a a b. FOR NEW CONSTRICTION OR NEW LIGHTING REQUIRED THROUGHOUT,PROVIDE AND INSTALL 3. PROVIDE AND INSTALL 6'-8"SOLID CORE, PAINT/STAIN-GRADE PRE-HUNG BIRCH WOOD DOORS • COLOR:INDICATED ON SHEET 4 COMMERCIAL GRADE 2X4 LED FIXTURES(W/40W,4700 LUMENS,3500K)AT ONE FIXTURE PER EVERY 75 WITH WOOD FRAME AND TRIM ARE PREFERRED IN THE EVENT THERE IS NO EXISTING STANDARD cK USABLE SF,IN PLACE TO ACCOMMODATE MINIMUM 50 FOOTCANDLES AT DESK LOCATIONS. TO MATCH. DOORS FOR ROOMS 102A, 102B, 104, 105,&106 MUST BE SOLID CORE,REMAINING GYPSUM CEILINGS:ONE FINISH COAT OVER AN EXISTING FINISH OR PRIMER. w w c. EDWARD JONES HAS ESTABLISHED A PREFERRED VENDOR ARRANGEMENT WITH VILLA LIGHTING. ROOMS TO BE HOLLOW CORE UNLESS NOTED OTHERWISE ON PLANS. REPLACE AS REQUIRED. • SHERWIN WILLIAMS: co v col PLEASE CONTACT VILLA LIGHTING FOR QUOTATION ON THE LIGHTING SPECIFICS. 4. DOORS AND FRAMES TO BE PAINTED/STAINED PER FINISH SPECIFICATIONS ON SHEET 4. • PRIMER:SHERWIN-WILLIAMS PROMAR 200 ZERO VOC,INTERIOR LATEX z v 01 d. ALL NEW AND EXISTING LIGHTING SHOULD BE FULLY OPERATIONAL AND IN GOOD CONDITION. 5. ALL NEW HARDWARE TO BE A HANDICAP ACCESSIBLE LEVER STYLE. PROVIDE NEW PASSAGE PRIMER,BS28W02600. o - e. EXIT AND/OR EMERGENCY LIGHTING TO BE INSTALLED AS REQUIRED PER CODE. HARDWARE FOR NEW DOOR(S)TO MATCH EXISTING.IN THE EVENT THAT THE OWNER HAS • FINISH COAT:SHERWIN-WILLIAMS PROMAR 400 INTERIOR LATEX FLAT, M f. A SWITCH SHOULD OCCUR AT MAIN ENTRANCE AND WIRED TO OPERATE LIGHTING IN 101 AND ESTABLISHED NO STANDARD FINISH,BRUSHED NICKEL IS PREFERRED. B30W451, LJJ a o 0 PASSAGE 103 AS SHOWN ON PLAN,UNLESS EXISTING. IF SPACE HAS MORE THAN ONE EGRESS • COLOR:SW7005 PURE WHITE a. o DOOR,SWITCH SHOULD BE 3-WAY TO OPERATE AT BOTH ENTRANCES;EXCLUDING BRANCHES IN CA. 9. FLOORING(UNLESS BUILDING STANDARD APPLIES) z w � w g. PROVIDE AND INSTALL EXIT LIGHTING AT EGRESS DOORS AS REQUIRED BY CODE. a. IF NEW CONSTRUCTION,GC REQUIRED TO COMPLETE MOISTURE TEST.IF MOISTURE READING IS INTERIOR WOOD DOORS,JAMBS&FRAMES(METAL OR WOOD) h. IF EXISTING,VERIFY THAT ALL LENSES AND LAMPS ARE CONSISTENT IN COLOR.LENSES TO BE ABOVE 95,NOTIFY INTERFACE FLOORING IMMEDIATELY. FOR PAINT ONLY:TWO FINISH COATS OVER A PRIMER;FOR STAIN:ONE COAT,UNLESS 2 c:;-- o FREE OF ANY VISIBLE DAMAGE,STAINS,OR DISCOLORATION OF ANY KIND. b. THE EDWARD JONES STANDARD CARPET,VINYL BASEBOARD,AND LUXURY VINYL PLANK SHALL BE SECOND COAT IS NEEDED FOR A CONSISTENT FINISH THROUGHOUT. o' a co i. IN ROOMS 101 AND 103,HARD WIRE ONE LIGHT FIXTURE TO REMAIN ON AT ALL TIMES IF NOTED IN INSTALLED PER MANUFACTURER'S INSTRUCTIONS.INSTALL METHOD FOR CARPET IS DIRECT GLUE IN • SHERWIN WILLIAMS: j5,, SITE SPECIFIC NOTES ON SHEET 3 OF 8. LIGHTS TO BE ORIENTED TO ALLOW ILLUMINATION OF AN ASHLAR PATTERN.SEE MANUFACTURER'S INSTRUCTIONS FOR POST-INSTALLATION/CLEANING • PRIMER:SHERWIN-WILLIAMS PROMAR 200 ZERO VOC,INTERIOR LATEX H Q, INTERIOR COMMON AREAS FROM EXTERIOR DURING EVENING HOURS. (THIS ITEM TO BE ADJUSTED INSTRUCTIONS.LUXURY VINYL PLANK JOINTS TO BE STAGGERED 6"+IN RANDOM PATTERN. PRIMER, BS28W02600. Q) E, IN TITLE 24 REGIONS TO MEET LOCAL ENERGY REQUIREMENTS).SEE CONTRACTOR'S NOTES ON • ADHESIVE:2000 PLUS • 1ST&2ND COATS:SHERW►N-WILLIAMS PROCLASSIC WATERBORNE 7:w Fe SHEET 3 OF 8. ADHESIVE SPREAD RATE:35 SY/GAL INTERIOR ACRYLIC SEMI-GLOSS ENAMEL,B31W51 SERIES 0 ,; j. PROVIDE AND INSTALL(1)COMMERCIAL LINEAR SLOT WALL WASH LED TO ILLUMINATE INTERIOR a. PROVIDE A SMOOTH SURFACE FOR FLOORING INSTALLATION. IF FLOOR IS NOT LEVEL CONTACT • COLOR:INDICATED ON SHEET 4 '- LOGO.NEW CEILING TILE REQUIRED.INSTALL IN CEILING 3'-0"AWAY FROM WALL AND CENTERED ON DESIGNER IMMEDIATELY. OR '� w w N PARTITION ABOVE INTERIOR LOGO IN 101 AS DETAILED ON SHEET 4. PROVIDE A SEPARATE SWITCH b. PLEASE CONTACT INTERFACE SERVICES IMMEDIATELY AFTER AWARD OF CONTRACT TO • SHERWIN WILLIAMS: u_ N FOR LIGHT;SWITCH TO BE INSTALLED AT ENTRY DOOR UNLESS OTHERWISE SHOWN. COORDINATE FLOORING DELIVERY. • STAIN:SHERWIN-WILLIAMS MINWAX PERFORMANCE SERIES TINTABLE Z o o • BASIS OF DESIGN TO BE: 1. GC: CARPET MATERIAL MUST BE ORDERED FROM INTERFACE SERVICES. EDWARD JONES HAS A WOOD STAIN `...) MARK ARCHITECTURAL LIGHTING NATIONAL CONTRACT WITH INTERFACE SERVICES. COORDINATION AND PURCHASE,AND • COLOR:INDICATED ON SHEET 4. ¢ ZLi PRODUCT:SLOT 2 LED INSTALLATION OF ALL FLOORING AND FINISHES AS LISTED IN EXHIBIT A,WILL BE THE FULL W ¢2:1 CO o SIZE:8'-0"LONG RESPONSIBILITY OF THE GC. • OR COMPARABLE ALTERNATE j c. ALL CARPET TO BE INSTALLED PER CRI STANDARDS(CARPET&RUG INSTITUTE). d. CARPET TO BE VACUUMED WITH NO PROTRUDING YARN AT SEAMS. IF CARPET IS EXISTING TO FINISH REMAIN IN SPACE,GC TO HAVE CARPET PROFESSIONALLY CLEANED. SPECIFICATIONS e. A FULL BOX OF CARPET TILE SHALL BE LEFT IN STORAGE AREA OF EDWARD JONES SPACE.ALL REMAINING LUXURY VINYL PLANK SHOULD BE LEFT IN EDWARD JONES'STORAGE AREA. SHEET 7 of 8 , ..�.� -. _ _ - ___t�_ n w__ _-..t...u.:___ ti_— n:.- ,.-,.:ti— -k. -------------. -- z: —,—_ EDWARD JONES GENERAL BUILDING AND FINISH SPECIFICATIONS EXTERIOR ONLY-METAL DOORS,JAMBS&FRAMES TWO FINISH COATS OVER A PRIMER. ' 12. LOW VOLTAGE(ALSO KNOWN AS PHONEIDATA CABLING) BOC REQUIREMENTS: • SHERWIN WILLIAMS: LOW VOLTAGE WIRING(ALSO KNOWN AS PHONE/DATA CABLING) • PRIMER:SHERWIN-WILLIAMS DTM ACRYLIC PRIMER/FINISH, B66W1 a. LOW VOLTAGE IMPLIES THE ACTUAL WIRE OR CABLE THAT IS RUN FROM THE BOC TO EACH NOTE:CONDUIT IS INSTALLED INSIDE WALL.IF WALL IS EXISTING,CONDUIT • 1ST&2ND COATS:SHERWIN-WILLIAMS PROCLASSIC WATERBORNE INTERIOR ACRYLIC PHONE,COMPUTER,PRINTER,AND FUTURE WORKSTATION LOCATION, WITH THE EXCEPTION MAY BE SURFACE MOUNTED.MUST HAVE ROOM FOR EQUIPMENT TO INSTALL SEMI-GLOSS ENAMEL,B31W51 SERIES OF THE DEMARC EXTENSION.LOW VOLTAGE WORK IS DONE BY EDWARD JONES BRANCH ON PLYWOOD.(SEE KEYED NOTE#1 ON SHEET 3 FOR CLARIFICATION.) • COLOR:INDICATED ON SHEET 4 INSTALL DEPT.THROUGH A PREFERRED NATIONAL VENDOR. THIS WORK IS DONE AFTER THE ( kSPACE IS TURNED OVER TO EDWARD JONES. 3/4"CONDUIT TO4±] [ II ^I_r 3/4"CONDUIT TO ALL 11.ELECTRICAL b. IF LOW VOLTAGE WORK IS REQUIRED TO BE PERMITTED AND INSPECTED AS NOTED ON EXHIBIT LEC DMARC BOX I WORKSTATION LOCATIONS I I= a a: ELECTRICAL TO INCLUDE OUTLETS AS SHOWN ON EXHIBIT A,INCLUDING DEDICATED OUTLET AS A,GENERAL CONTRACTOR IS TO COORDINATE THE INSTALLATION WITH EDWARD JONES; SINGLE GANG PHONE 2'0"w X 3'0"h FRT PLYWOOD SHOWN ON PLAN. CONTACT LEASING COORDINATOR/PROJECT MANAGER LISTED ON EXHIBIT A. NOTE THAT PRE BOX WITH PULL STRING BACKER BOARD,PAINTED TO 1. GENERAL PURPOSE OUTLETS WIRE IS NOT STANDARD AND IS ONLY DONE WHEN REQUIRED VS.BEING DONE FOR AND#6 GROUND WIRE MATCH WALL W/LABEL EXPOSED, • ALL OUTLETS TO BE PLACED AS SHOWN ON DRAWING. CONVENIENCE. PREWIRE WILL BE REQUIRED IF CEILING HEIGHT IS OVER 9'-0"IN US AND OVER BY GC(INC TO RUN(1) INSTALL AT 36"A.F.F.TO BOTTOM; • ONE(1)QUAD OUTLET AT FUTURE WORKSTATION LOCATION AND(2)QUAD OUTLETS AT 10'-0"IN CANADA;AND/OR IF INDICATED ON SHEET 3. CAT5E LINE TO THIS BOARD SUPPLIED&INSTALLED BY i BOA WORKSTATION. c. NOTIFY LEASING COORDINATOR/PROJECT MANAGER OF LOW VOLTAGE REQUIREMENTSi. LOCATION) GC. I • AT ALL TERMINALS AND OTHER OFFICE EQUIPMENT AS SHOWN ON THE PLAN. NEEDED IN ORDER TO OBTAIN CERTIFICATE OF OCCUPANCY. 2. DEDICATED OUTLET 1. ELECTRICAL BOXES-4X2-1/8D HANDY BOX MUST BE USED, PER DIAGRAM BELOW FOR ALL ACTIVE SINGLE GANG DEDICATED SIMPLEX OUTLET TO w w • DEFINITION:A DEDICATED OUTLET IS WIRED DIRECTLY TO THE MAIN POWER DISTRIBUTION LOW VOLTAGE APPLICATIONS IN NEW WALLS AND CONCRETE WALLS. PHONE BOX WITH PULL BE MARKED WITH"D"&ORANGE a I PANEL THROUGH A DESIGNATED(DEDICATED)CIRCUIT BREAKER.THE DEDICATED OUTLETS 2. MUD RINGS-MPLS METAL SINGLE GANG DRYWALL MOUNTING PLATE,PER DIAGRAM BELOW STRINGS BY GC.INC TO INDICATE DEDICATED BY GC. x o ARE COLOR CODED TO DISTINGUISH THEM FROM GENERAL-PURPOSE OUTLETS.ONLY THE FOR ALL LOW VOLTAGE APPLICATIONS IN EXISTING WALLS. RUN REMAINING(4) I _ I DOUBLE GANG PHONE BOXES.GC N z w BOC SHOULD BE PLUGGED INTO THE DEDICATED OUTLET.THE TECHNICAL INFORMATION CAT5E LINES TO THIS 1 TO RUN PULL STRING THROUGH Z -' FOR THIS OUTLET IS AS FOLLOWS: CONDUIT-DEMISED PREMISES LOCATION) I EACH CONDUIT RUN.INC TO RUN Lu N N • ONE DEDICATED OUTLET(SIMPLEX,NOT DUPLEX)REQUIRED FOR THE BOC(SEE LEGEND a. CONDUIT STUB-UPS TO BE INSTALLED IN NEW WALLS WHERE PHONE/DATA/PRINTERS ARE I REMAINING CABLES TO VARIOUS < < "—' a) } ON SHEET 5 OF 8). SHOWN ON THE FLOOR PLAN(INDICATED BY TRIANGLE♦)IF THE NEW CEILING IS DRYWALL, STUD WORKSTATION LOCATIONS-SEE p Lu -2 w • OUTLET TO BE STANDARD 3-PRONG, 120 VOLT,20 AMP,DEDICATED CIRCUIT. INSTALL CONDUIT FROM THE POINT OF CONNECTION(PHONES/DATA/PRINTER LOCATIONS LOW VOLTAGE WIRING SPECS. W co a • OUTLET TO BE SIMPLEX,ORANGE COLOR CODED RECEPTACLE(NEMA TYPE 5-15 R/IG INDICATED WITH V)AND STUB ABOVE CEILING WITH PULL STRING RUN TO THE POINT OF >LLI z OUTLET,GE5362-IG OR EQUIVALENT). TERMINATION(CLIENT SERVER OR BOC). raj = c� 13.BRAND WALL METAL REVEAL • ALL GROUNDS MUST HAVE SAME GROUND POTENTIAL. b. CONFIRM ACTUAL LOCATIONS ON EXHIBIT A PRIOR TO INSTALLATION. EXISTING 0) 1- w 3. RECESSED OUTLET CONSTRUCTION-CONDUIT NOT TO BE DONE IF IT REQUIRES REMOVAL OF DRYWALL PARTITIONS OR a. CONTRACTOR TO ORDER METAL REVEAL(EDJ-625-625)FROM FRY REGLET AND I__ x vj o INSTALL AS SHOWN ON BRAND WALL.REFERENCE SHEET 4-FINISH PLAN FOR 0 0 U 'n • LEVITON RECESSED ONE-GANG DUPLEX RECEPTACLE(15A-125VAC 2-POLE,3-WIRE-NEMA CEILINGS,UNLESS PRIOR APPROVAL RECEIVED FROM EDJ DESIGNER. IF WIREMOLD PRODUCT IS Z ct z < M LOCATION AND ELEVATION. o 1- M 5-15R) CAT NO.689 TO INCLUDE ELECTRICAL BOX. REQUIRED, INSTALL PANDUIT RACEWAY LD10E16 A. 1. DRYWALL GAP TO BE LEFT FOR REVEAL TO BE INSERTED AS SHOWN BELOW. g 0 o • CATALOG NO.012-00689-00W;UPC NO.07847731284 1 c. PROVIDE ONE SINGLE GANG BOX(ONE PER TRIANGLE)AND PULL STRING AT EACH CONDUIT o c.> „ • IF ABOVE SPECIFICATION IS UNAVAILABLE,FIND COMPARABLE ALTERNATIVE LOCATION. LABEL PULL STRINGS AT POINT OF TERMINATION(BOC)WITH ROOM NUMBER OF POINT 2. METAL REVEAL TO BE SECURED IN PLACE WITH SCREWS. z a � ww 3. TAPE AND APPLY JOINT COMPOUND AS SHOWN BELOW. z o c')b. ALL OUTLETS TO BE 110 VOLT STANDARD 3-PRONG OUTLETS THAT MEET STATE AND LOCAL OF CONNECTION. o I- w REQUIREMENTS(NEMA TYPE 5-15R).THE GROUNDING CONDUCTORS FOR THE BUILDING'S d. IF WALLS ARE EXISTING AND CONDUIT IS NOT INSTALLED,PROVIDE PULL STRING AND CUT IN A 4. METAL REVEAL AVAILABLE IN 10'-0"SECTION ONLY. c� w CIRCUITS SHOULD BE REFERENCED TO THE POINT OF"ZERO CURRENT"WITHIN THE ELECTRICAL NEW BOX AT THE SAME LOCATIONS. 5. INSTALL END CAP CLIP WHERE APPLIES AT OPEN ENDS " "' tl I SUPPLY SYSTEM,WHICH IS WHERE THE NEUTRAL AND GROUND FOR THE SYSTEM ARE TIED e. STANDARD STUB-UP QUANTITY:TEN(10)3/4"DIAMETER LOCATIONS,UNLESS NOTED OTHERWISE �I TOGETHER. ON PLANS-INDICATED BY TRIANGLE SYMBOL ON FLOOR PLANS. II; w 4 c. EXISTING OUTLETS CAN BE USED TO MEET THE REQUIREMENTS FOR GENERAL-PURPOSE 1. 3/4"CONDUIT LOCATIONS „S 1 n N Tape&Joint w r- OUTLETS ONLY. VERIFY EXISTING OUTLETS TO REMAIN ARE IN WORKING ORDER. • (2)AT BOA(ROOM 101) Compound Zo v rn d. NEW ELECTRICAL OUTLETS TO BE INSTALLED WHERE SHOWN ON PLANS AT 18"A.F.F.UNLESS AN • (1)AT OFFICE 102A 0 C., EXISTING DEVICE IS ALREADY WITHIN 36"OF THE DESIRED LOCATION;EXCLUDING WORKSTATION •• (1)AT OFFICE 102B # 0 w LOCATIONS SHOWN ON SHEET 5. • (4)AT BOC INTO DOUBLE GANG BOXES f w c eL e. DEMO/REMOVE OUTLETS ABOVE 18"A.F.F.UNLESS NOTED OTHERWISE ON PLANS. • (2)AT INCOMING PHONE/DATA LINES TO BOC PER PLAN(ONE ACTIVE FOR PHONES AND DIM.8 c o O f. INSTALL OR REPLACE ALL OUTLET AND LIGHT COVERS/SOCKETS WITH WHITE THROUGHOUT. ONE W/#6 GROUND WIRE RUN FROM BOX TO ELECTRICAL PANEL TO GROUND BOX FORu-S z `� Metal Stud END CAP () A x g. ALL COMPUTER EQUIPMENT FOR THIS OFFICE IS SENSITIVE TO HIGH ELECTROMAGNETIC DATA) Framing �cuP wCT INTERFERENCE(EMI).IT IS RECOMMENDED THAT THE AMBIENT EMI IN THE OFFICE DOES NOT • (1)AT OPEN 106+IF INDICATED ON PLAN I o o o II a EXCEED 2 MG.PLEASE NOTIFY DESIGNER IMMEDIATELY IF SITE IS LOCATED NEAR EXISTING 2. ADDITIONAL MAY BE NEEDED IF ADDITIONAL DATA PORTS ARE SHOWN ON PLAN. 7i8- ct U) a U) POWER LINES,TRANSFORMERS,SUB-STATIONS,ETC. f. ALL BOXES AND CONDUIT AT BOC LOCATION TO BE INSTALLED PER DETAIL.#6 GROUND WIRE ikli ! ;�, 1 h. LANDLORD RESPONSIBLE FOR SETTING UP UTILITIES OR PROVIDING TEMPORARY ELECTRICAL IN MUST BE INSTALLED AND TERMINATED ON A BUSBAR FOR#6 WIRE MOUNTED ON THE BOTTOM y F" SPACE THAT IS NEW CONSTRUCTION OR SPACE THAT IS BEING SUBDIVIDED. GENERAL CORNER OF THE BACK BOARD.THE BUSBAR SHOULD HAVE 4 TO 6 TERMINALS. F. CONTRACTOR IS RESPONSIBLE FOR ASSURING TEMPORARY POWER FOR ALL FINISH OUT WORK IF Ii ' g I NOT ALREADY PROVIDED. CONDUIT AND PHONE LINES FROM BUILDING SOURCE TO EXTENDED DEMARC(BOC) w OD I. ELECTRICAL CONTRACTOR TO VERIFY EXISTING ELECTRICAL PANEL WILL ACCOMMODATE a. GENERAL CONTRACTOR TO INSTALL(2)3/4"CONDUIT FROM THE BUILDING SOURCE TO THE '` aIn EDWARD JONES REQUIREMENTS;UPGRADE AS REQUIRED. EXTENDED DEMARC LOCATION WITHIN THE BRANCH(BOC LOCATION SHOWN ON PLAN). 14.MISCELLANEOUS-(ONLY IF SHOWN ON EXHIBIT A) '� w N j. CONTRACTOR TO INSTALL 2'X3'MINIMUM BACKER BOARD OF FRT PLYWOOD AT BOC LOCATION. ****IF DATA LINES ENTER BUILDING AT A DIFFERENT LOCATION THAN PHONE LINES,(1)CONDUIT a. FIXED WINDOW ;"' i N I BOARD TO BE PAINTED TO MATCH THE WALL WHEN THE WALL IS SCHEDULED FOR PAINT PER THE WILL NEED TO COME FROM THE DATA SOURCE TO THE GROUNDED BOX AT THE BOC LOCATION. 1. NEW INTERIOR WINDOW BETWEEN FA OFFICE AND BOA AREA TO BE A FIXED, Z wo c FINISH SCHEDULE. CONFIRM WITH FIRE MARSHALL PRIOR TO PAINTING AND LEAVE RATING STAMP REMAINING CONDUIT SHOULD BE RUN IN FROM THE PHONE LINE SOURCE TO THE BOC 42"W X 30"H AND INSTALLED AT 42"A.F.F.,UNLESS NOTED OTHERWISE;FRAME Z = Cii EXPOSED WHENEVER REQUIRED. BOARD TO BE INSTALLED AT 36"A.F.F.TO THE BOTTOM AT THE LOCATION***** TO MATCH DOOR FRAMES. I LOCATION SHOWN ON THE PLAN. REFER TO SHEET 8 OF 8 FOR EXACT LOCATION. b. CONTACT BRANCH REAL ESTATE IMMEDIATELY IF THERE ARE ANY QUESTIONS REGARDING THE 2. GLASS TO BE CLEAR,''/4"TEMPERED STATIONARY PANEL.GLIDERS AND w m a k. ELECTRICIAN TO INSTALL 3/4"CONDUIT&BOX WITH PULL STRING OR MUD RING(EXISTING WALL) NUMBER OF PHONES LINES OR LOCATION OF DEMARC EXTENSION CONDUIT. MIRRORED WINDOWS NOT ALLOWED. AT ALL LOCATIONS(SEE SECTION 12 BELOW)WITH LOW VOLTAGE COMMUNICATION b. FIREPLACES,STOVES,SHOWERS,TUBS CONNECTIONS. INSTALL(1)SINGLE GANG BOX AT EACH LOCATION INDICATED ON THE DRAWING 1. ALL GAS AND PLUMBING LINES TO THESE ELEMENTS/FIXTURES TO BE FINISH WITH A TRIANGLE(V);UNLESS ADDITIONAL ARE SHOWN. DO NOT INSTALL A DOUBLE GANG BOX RENDERED INOPERABLE AND ALL LINES TO BE CAPPED. SPECIFICATIONS 1 AT LOCATIONS WHERE(2)SYMBOLS ARE ADJACENT. REFER TO LEGEND AND PLANS ON EXHIBIT A 2. IF WOOD BURNING FIREPLACE EXISTING GC TO INSTALL COVER MADE FROM FOR LOCATIONS OF DOUBLE GANG BOXES. LUMBER AND DRYWALL THAT RESTS INSIDE THE OPENING AND DOES NOT SHEET 8 DAMAGE THE FIREPLACE. of 8