Specifications [3u(2aOa a`.1
I2."15—e s P0..c4IL)-4
OFFICE COPY
Calculations for
Hudson Plaza
12900-12950
Suite 245
Tigard, OR
g ) °cC%,
F A ES ED
SA M, OR
21 Se ,tember 2021
Architect
Ronald James Ped Architect, PC
1220 20th Street SE
Salem, OR 97302
(503)363-1456
Email rjp@rktect.corn
Project Number 2164
DIE3L JOIST WALL AS NEEDED
PROPPOSED 4x12 BEAM EXISTING BEAM
NI 1111 pi in mi mai 1.= in• INN I.. mil mom Ems
41(1 7/ .('(2 (TYR) TOP FLANGE I-IANGER
f1/4' L/IttismP-- —
ATA\ti EXISTING FLOOR JOIST
EE
A2.1
REMOVE BEARING WALL
- — — — — —
\b1
-\\ \- — — —
T -1 T
— 4 —
A2.1
(TYFJ TOP FLANGE 1-IANGER
RIM JiDIST
1
,
Project:joist raiN
,
StruCalc 9.0 page
Location: MSFB2
Multi-Span Floor Beam of
[2015 International Building Code(2015 NDS)]
3.5 IN x 5.5 IN x 4.0 FT
#2-Douglas-Fir-Larch-Dry Use StruCalc Version 10.0.1.6 9/21/2021 9:24:40 AM
Section Adequate By:20.0%
Controlling Factor:Moment
DEFLECTIONS Center LOADING DIAGRAM
Live Load 0.03 IN L/1438
Dead Load 0.02 in
Total Load 0.05 IN L/903
Live Load Deflection Criteria:L/360 Total Load Deflection Criteria: L/240
REACTIONS A
Live Load 900 lb 900 lb
Dead Load 533 lb 533 lb
Total Load 1433 lb 1433 lb
Bearing Length 0.66 in 0.66 in
BEAM DATA Center
Span Length 4 ft
Unbraced Length-Top 0 ft 4ft
Unbraced Length-Bottom 4 ft
Floor Duration Factor 1.00
Notch Depth 0.00
FLOOR LOADING Center
MATERIAL PROPERTIES . Floor Live Load FLL= 60 psf
#2-Douglas-Fir-Larch Floor Dead Load FDL= 35 psf
Base Values Adjusted Floor Tributary Width Side One TW1 = 5.5 ft
Bending Stress: Fb= 900 psi Fb'= 1170 psi Floor Tributary Width Side Two TW2= 2 ft
Cd=1.00 CF=1.30 Wall Load WALL= 0 plf
Shear Stress: Fv= 180 psi Fv'= 180 psi
Cd=1.00 BEAM LOADING Center
Modulus of Elasticity: E= 1600 ksi E'= 1600 ksi Reduced Floor Live Load 60 psf
Comp.-I-to Grain: Fc- = 625 psi Fc--I-'= 625 psi Total Live Load 450 plf
Total Dead Load 263 plf
Controlling Moment: 1433 ft-lb Beam Self Weight 4 plf
2.0 Ft from left support of span 2(Center Span) Total Load 717 plf
Created by combining all dead loads and live loads on span(s)2
Controlling Shear: 1433 lb
At left support of span 2(Center Span)
Created by combining all dead loads and live loads on span(s)2
Comparisons with required sections: Req'd Provided
Section Modulus: 14.7 in3 17.65 in3
Area(Shear): 11.94 in2 19.25 in2
Moment of Inertia(deflection): 12.9 in4 48.53 in4
Moment: 1433 ft-lb 1720 ft-lb
Shear: 1433 lb 2310 lb
StruCalc 9.0 page
Project:joist' , ,„ /,--
Location:JST1 i,
Floor Joist
of
[2015 International Building Code(2015 NOS)]
Red-145/11.875-Redbuilt x 10.25 FT @ 24 O.C.
Section Adequate By:4.2% StruCalc Version 10.0.1.6 9/21/2021 9:28:33 AM
Controlling Factor: End Reaction
DEFLECTIONS Center LOADING DIAGRAM
Live Load 0.11 IN L/1144
Dead Load 0.06 in
Total Load 0.17 IN L/722
Live Load Deflection Criteria: L/480 Total Load Deflection Criteria: L/360
REACTIONS A B
Live Load 615 lb 615 lb
Dead Load 359 lb 359 lb
Total Load 974 lb 974 lb
Bearing Length 1.75 in 3.50 in
Web Stiffeners No No
SUPPORT LOADS A B 1
Live Load 308 plf 308 plf -'1`— 10.25 ft
Dead Load 180 plf 180 plf H
Total Load 487 plf 487 plf
I-JOIST PROPERTIES JOIST DATA Cen et
Red-145/11.875-Redbuilt Span Length 10.25 ft
Base Values Adjusted Unbraced Length-Top 0 ft
Moment Cap: Mcap= 4685 ft-lb Mcap'= 4685 ft-lb Unbraced Length-Bottom 0 ft
Cd= 1.00 Floor sheathing applied to top of joists-top of joists fully braced.
Shear Stress: Vcap= 1785 lb Vcap'= 1785 lb Floor Duration Factor 1.00
Cd= 1.00
Reaction A: Rcap= 1015 lb Rcap'= 1015 lb JOIST LOADING
Reaction B: Rcap= 1560 lb Rcap'= 1560 lb Uniform Floor Loading Center
E.I.: El= 375 lb-in2 El'= 375 lb-in2 Live Load LL= 60 psf
Dead Load DL= 35 psf
Controlling Moment: 2495 ft-lb Total Load TL= 95 psf
5.12 Ft from left support of span 3(Right Span) TL Adj. For Joist Spacing wT= 190 plf
Created by combining all dead and live loads.
Controlling Shear: 974 lb
At left support of span 2(Center Span)
Created by combining all dead and live loads.
Comparisons with required sections: Rea'd Provided
E.I.: 187 in2-lb E6 375 in2-lb xE6
Moment: 2495 ft-lb 4685 ft-lb
Shear: 974 lb 1785 lb
` l FIRsEouRATrce.maED Pilkington Pyrostop `q f
ny solutions°
VI— one
Fire-Rated,Safety-Rated Transparent Wall Panel
Fire-Rating: 45-120 Minutes A BIM 3D Model Available
Pilkington Pyrostop®is a fire-rated and impact safety-rated glazing material that blocks radiant
heat,protecting people and valuables on the non-fire side of the glass where radiant heat transfer
might be a concern.It is listed for use in doors,sidelites,transoms,borrowed lites and wall 0 UL Classified&Labeled
applications.
() Fire-Rated
FEATURES
• Fire-rated for up to 120 minutes with required • Comprised of layers of Pilkington Optiwhiten, b Hose Stream Tested
hose stream test nearly colorless,wireless,low-iron float glass
• Impact safety-rated-meets ANSI Z97.1 and and clear intumescent interlayers ® Impact-Rated
CPSC 16 CFR1201(Cat.I and II) • Multi-laminate,not a sensitive polymer gel
• Fits in most Fireframes®frame and door unit tiI Heat Barrier
systems byTGP • For use in interior and exterior applications
)
• Available in insulated units with other glass • Most configurations are available with a Positive Pressure Tested
products,including(but not limited to): translucent interlayer for added obscurity and
Tinted;Art Glass;One-Way Mirror;Low-E; privacy
Reflective;Security Glass • Available with bullet resistance to UL Level III
• Withstands thermal shock • Pilkington Pyrostop can be combined
• Large sizes available with Vision Control®integrated cord-free
• May be lightly sandblasted or etched on one louvers in a UL tested fire protection rated
side without affecting fire rating glazing system available directly from Unicel
Architectural
• 5-year limited warranty
• Protection against radiant and conductive
heat transfer
Plikington Pyrostop sales are a cooperative effort between Technical Glass Products and Pilkington North America.
LISTINGS/STANDARDS
Classified and labeled by Underwriters Laboratories,Inc.®and Underwriters Laboratories of Canada.File number for labeled fire-rated assemblies is
R13377(45 minutes)and R38725(60-120 minutes),Tests performed in accordance with:
UL 9 NFPA 80 CAN4 S-104 ASTM E119 MEA 241-00-M
UL 10B NFPA 251 CAN4 S-106 LARR 25798
UL 10C NFPA 252 CAN/ULC-S101
UL 263 NFPA 257
fireglass.com I 800.426.0279 T TECHNICAL GLASS PRODUCTS"
I
Pilkington Pyrostop
LABELING
Each piece of Pilkington Pyrostop shall be permanently labeled with the Pilkington Pyrostop logo,UL logo and fire rating.
STORAGE&HANDLING
Pilkington Pyrostop must be handled with care during transportation,storage,inspection and installation.It should be stored in dry conditions,
stocked vertically and fully supported in a manner which prevents the glass from sagging.During storage and transportation,the temperature of
Pilkington Pyrostop should not exceed 122°F(50°C).Do not expose the"non-PUB"side of the glass to UV light.Do not remove the protective edge
tape.See manufacturer's installation and warranty information for further details.
FAMILY OF PRODUCTS
TGP offers a complete family of products for all your fire-rated glazing needs,ranging from 20 minute to 3 hour applications.More information is
available online at fireglass.com,or by calling 800.426.0279.
Fireglass®20 Pilkington Pyrostop®
Fire-rated,impact safety-rated glass Fire-rated,impact safety-rated transparent wall panels
FireLite® WireLite®
Fire-rated glass ceramic Fire-rated,wired glass
FireLite®NT WireLite®NT
Fire-rated,impact safety-rated glass ceramic with surface-applied film Fire-rated,impact safety-rated wired glass with surface-applied film
FireLite Plus® Fireframes®
Fire-rated,impact safety-rated glass ceramic Fire-rated framing&doors for use with all TGP glass products
FireLite®IGU
Fire-rated or fire/impact safety-rated insulated glass units
Il
fireglass.com I 800.426.0279 irc,p TECHNICAL GLASS PRODUCTS"
�3
•
PRODUCT DATA Pilkington. Pyrostop
DAYLIGHT STC RATING MAX.WIDTH MAX.HEIGHT
FIRE MANUFACTURER'S SUPPLY NOMINAL WEIGHT U-VALUE TRANS. APPROX. ASSEMBLY MAX.EXPOSED OF EXPOSED OF EXPOSED
RATING DESIGNATION FORM THICKNESS APPROX. APPROX. (dB) AREA GLAZING OR GLAZING
(%)
45 min. 45-200 Single 3/4"(19 mm) 9.22 lb/ft' 86 86 40 OTHER THAN DOORS 4,500 in2(2.90 m2) 95-1/4"(2.42 m) 95-1/4"(2.42 m)
Glazing (45.00 kg/m2) DOOR 3,724 in'(2.40 m2) 41-5/8"(1.06 m) 89-3/4"(2.28 m)
W 60 min. so-lot Single 7/8"(23 mm) 10.86lb/ft' $3 87 41 OTHER THAN DOORS 5,616 in2(3.62 m2) 96"(2.44 m) 96"(2.44 nil
N Glazing (53.00 kg/m) DOOR 3,724 in (2.40 m) 41-5/8"(1.06 m) 89-3/4"(2.28 m)
= Single 12.90 lb/ft2 OTHER THAN DOORS 7,442 in2(4.80 m2) 9G"(2.44 my 118-1/8"(3.00 m)
60 min. 60-201 Glazing 1-1/16"(27 mm) (63.00 kg/m2) .83 86 44 DOOR 3,724 in'(2.40 m2) 41-5/8"(1.06 m) 89-3/4"(2.28 m)
O
Single 17.61 lb/ft2 OTHER THAN DOORS 3,724 in2(2.40 m2) 96"(2.44 m) 96"(2.44 m)
W 90 min. 90-102 Glazing 1-7/16"(37 mm) (86.00 kg/m2) .74 84 45 DOOR 3,724 in2(2.40 m2) 41-5/8"(1.06 m) 89-3/4"(2.28 m)
H
Z 2-1/B"(54 mm)
(with 8 mm 21.71 Ib/ft2
2 hours 120-104 I.G.Units spacer
r,or wi3/8 (106 00 kg/m2) .44 75 46 OTHER THAN DOORS 3,730 in'(2,41 in') 111"(2.81 m) 111"(2.81 m)
14 mm spacer)
22.94 lb/ft2
2 hours 120-106 I.G.Units 2-1/4"(57 mm) (112,00 kg/mz) .42 75 46 OTHER THAN DOORS 3,730 in2(2.41 m2) 111"(2.81 m) 111"(2.81 m)
30.72 lb/ft2 FIREFRAMES
2 hours 120-401 I.G.Units 2-13/16"(72 mm)(150.00 kg/m2) .46 73 45 CLEARFLOOR°D 2,372 in2(1.53 m2) 47-1/4"(1.20 m) 50-3/8"(1.28 m)
SYSTEM
FIRE MANUFACTURER'S SUPPLY NOMINAL WEIGHT DAYLIGHT
STC RATING MAX.EXPOSED MAX.WIDTH MAX.HEIGHT
RATING DESIGNATION FORM THICKNESS APPROX. U-VALUE APPROX. APPROX. ASSEMBLY OF EXPOSED OF EXPOSED
(%) (dB) AREA GLAZING OR GLAZING
45 min. 45-200 Single 3/4"(19 mm) 9.22 lb/ft2 66 86 40 OTHER THAN DOORS 4,500 in2(2.90 m2) 95--1/4"(2.42 m) 95--1/4"(2.42 m)
Glazing (45.00 kg/m2) DOOR 3,724 in'(2.40 in2) 41-5/8"(1.06 m) 89-3/4"(2.28 m)
45 min. 45-260 I.G.Units 1-5/16"(33 mm) 12.29 lb/ft' .49 77 40 OTHER THAN DOORS 4,500 in2(2.90 in') 95-1/4"(2.42 m) 95-1/4"(2.42 m)
(60.00 kg/m2) DOOR 3,724 in2(2.40 m2) 41-5/8"(1.06 m) 89--3/4"(2.28 m)
12.29 lb/ft2 OTHER THAN DOORS 4,500 in2(2.90 m') 95-1/4"(2.42 in) 95-1/4"(2.42 m)
45 min. 45-360* I.G.Units 1-5/16"(33 mm) (60.00 kg/m2) •37-.39 59-71 40 DOOR 3,724 in'(2.40 m') 41-5/8"(1.06 in) 89-3/4"(2.28 m)
W
N 60 min. 60-201 Single 1-1/16"(21 mm) 12.90lb/ft2 83 86 44 OTHER THAN DOORS 7,442 in2(4.80 in') 96"(2.44 m) 118-1/8"(3.00 in)
= Glazing (63.00 kg/m2) DOOR 3,724 in2(2.40 m2) 41-5/8"(1.06 m) 89-3/4"(2.28 m)
Ce
15.98 lb/ft2 OTHER THAN DOORS 7,442 in'(4.80 in') 96"(2.44 m) 118-1/8"(3.00 m)
. CD60 min, 60-261 I.G.Units 1-5/8"(41 mm) .48 77 44
(78.00 kg/m2) DOOR 3,724 in'(2.40 in') 41-5/8"(1.06 m) 89-3/4"(2.28 m)
C
W I-- 60 min. 60-361" I.G.Units 1-5/8"(41 mm) 15.98 lb/ft2 37.39 5970 44 OTHER THAN DOORS 7,442 in2(4.80 m2) 96"(2.44 m) 118-1/8"(3.00 m)
X (78.00 kg/m2) DOOR 3,724 in2(2.40 m2) 41-5/8"(1.06 in) 89--3/4"(2.28 m)
W
90 min. 120-202 Single 1-9/16"(40 mm) 18.64 lb/ft2 .72 86 46 DOOR 3,724 in2(2.40 m2) 41-5/8"(1.06 in) 89-3/4"(2.28 in)
2 hrs Glazing (91.00 kg/m')
2-3/8"(60 mm)
90 min.- (with 14 mm 21.71 Ib/ft2
2 hrs 120-262 I.G.Units sp 54 acer,
or w th8 (106.00 kg/m2) .44 74 46 OTHER THAN DOORS 3,730 in2(2.41 m2) 111"(2.81 m) 111"(2.81 m)
8 mm spacer)
2-3/8"(60 mm)
90 min. 120-362* I.G.Units space(witr,or 2-1/8"mm 21.71 lb/ft' .35 33-68 46 OTHER THAN DOORS 3,730 in'(2.41 m2) 111"(2.81 m) 111"(2.81 m)
2 hrs (54 mm)with (106.00 kg/m2)
8 mm spacer)
*Performance values vary for exterior I.G.units based on coating and configuration. Some of the available Pilkington hard coatings include Eclipse Advantage,Soiar_ETM Solar Control Low-E
and Energy Advantage Low-E. Contact TGP for availability and integration of high performance hard and soft coated products.
WHEN PROVIDED PROJECT-SPECIFIC CRITERIA(SUCH AS WIND LOAD,SEISMIC MOVEMENT,STRUCTURAL,AIR/WATER RESISTANCE,ETC.),TGP CAN VERIFY THE INTENDED
FENESTRATION CONFIGURATION(GLASS AND FRAMING)WILL PERFORM TO MEET THOSE REQUIREMENTS.FOR APPROVED FRAMING SYSTEMS FOR USE WITH PILKINGTON
PYROSTOP,VISIT FIREGLASS.COM OR CALL 800.426.0279.
fireglass.com I 800.426.0279 "rGp TECHNICAL GLASS PRODUCTS" i
O March 2018 Technical Glass Products.Pilkington Optiwhite is a trademark and Pllkingtun Pyrustop is a registered trademark ut Pilkington plc.Vision Conlrul is a registered trademark of(dulcet Architectural,Technical Glass Products,Fireglass.Firetrames,Firetrames ClearFloor l
P and One Source.Many Solutions.are registered trademarks of Technical Glass Products This information is intended fur general reference only.For current listing details,please call Technical Glass Products.