Report . -- - 1., OFFICE COPY IIupao3I- o0 a36
COMcheck Software Version 4.1.5.3 08°3 Sviev Z4 ST
4/11*rilfEnvelope Compliance Certificate
RECEIVED
SEP 23 2021
CITY OF TIGARD
Project Information BUILDING DIVISION
Energy Code: 90.1 (2016)Standard
Project Title: Tigard Senior Housing
Location: Tigard,Oregon `
Climate Zone: 4c
Project Type: New Construction
Vertical Glazing/Wall Area: 30%
Performance Sim.Specs: EnergyPlus 8.1.0.009(EPW: USA_OR_Portlandintl.AP.726980_TMY3.epw)
Construction Site: Owner/Agent: Designer/Contractor:
8803 SW OMARA ST Destin Ferdun John Cline
TIGARD, OR 97223 Northwest Housing Alternatives SERA Architects
2316 SE Willard St 338 NW 5th Avenue
Milwaukie,OR 97222 Portland, OR 97209
(503) 654-1007 503-445-7372
ferdun@nwhousing.org johnc@seradesign.com
Building Area Floor Area
1-Residential Units(Multifamily) : Residential 44687
2-Other(Multifamily) : Nonresidential 2423
Envelope Assemblies
1 Assembly Gross Area Cavity Cont. Proposed Budget U-
or R-Value R-Value U-Factor Factor(e)
Perimeter
Roof 1: Insulation Entirely Above Deck,[Bldg.Use 1 -Residential Units] 11600 33.6 0.029 0.032
NORTH
North Wall:Wood-Framed, 16"o.c.,[Bldg.Use 1 -Residential Units] 2483 21.0 0.0 0.062 0.064
{ Window Fixed:Wood Frame:Fixed,Perf.Specs.:Product ID VPI 226 --- --- 0.260 0.310
Endurance,SHGC 0.22,VT 0.51,[Bldg.Use 1 -Residential Units](b)
Window Operable:Wood Frame:Operable,Perf.Specs.:Product ID VPI 92 --- --- 0.270 0.310
Endurance,SHGC 0.18,VT 0.51,[Bldg.Use 1 -Residential Units](b)
North Louvers:Wood-Framed, 16"o.c.,[Bldg.Use 1 -Residential Units] 4 0.0 0.0 0.292 0.064
North Concrete:Solid Concrete:8"Thickness,Normal Density,Furring: 173 --- 1.1 0.343 0.090
None,[Bldg.Use 1 -Residential Units]
North Metal Wrap:Wood-Framed, 16"o.c.,.[Bldg.Use 1 -Residential 45 10.0 0.0 0.101 0.064
Units]
EAST
East Wall:Wood-Framed,16"o.c.,[Bldg.Use 1 -Residential Units] 6183 21.0 0.0 0.062 0.064
Window:Wood Frame:Fixed,Pert.Specs.:Product ID VPI Endurance, 1275 --- --- 0.260 0.310
SHGC 0.22,VT 0.51,[Bldg.Use 1 -Residential Units](b)
Window:Wood Frame:Operable,Perf.Specs.:Product ID VPI 723 --- --- 0.270 0.310
Endurance,SHGC 0.18,VT 0.51,[Bldg.Use 1 -Residential Units](b)
West Louvers:Wood-Framed,16"o.c.,[Bldg.Use 1 -Residential Units] 40 0.0 0.0 0.292 0.064
West Concrete:Solid Concrete:8"Thickness,Normal Density, Furring: 56 --- 1.1 0.343 0.090
None,[Bldg.Use 1 -Residential Units]
West Metal Wrap:Wood-Framed, 16"o.c.,[Bldg.Use 1 -Residential 128 10.0 0.0 0.101 0.064
Units]
Project Title: Tigard Senior Housing Report date: 09/15/21
Data filename: P:\Architecture\1903070\C-Design Coordination\Jurisdictional\ComCheck\Tigard Senior Page 1 of 12
Housing.cck
•
Assembly Gross Area Cavity Cont. Proposed Budget U-
or R-Value R-Value U-Factor Factor(a)
Perimeter
SOUTH
South Wall:Wood-Framed,16"o.c.,[Bldg.Use 1 -Residential Units] 1789 21.0 0.0 0.062 0.064
Window:Wood Frame:Fixed,Perf.Specs.:Product ID VPI Endurance, 258 --- --- 0.260 0.310
SHGC 0.22,VT 0.51,[Bldg.Use 1 -Residential Units](b)
Window:Wood Frame:Operable, Perf.Specs.:Product ID VPI 103 --- --- 0.270 0.310
Endurance,SHGC 0.18,VT 0.51,[Bldg.Use 1 -Residential Units](b)
Window-Fiberglass Storefront:Wood Frame:Fixed,Perf.Specs.: 167 --- --- 0.340 0.310
Product ID Fiberglass Storefront System,SHGC 0.27,VT 0.64,[Bldg.
Use 1 -Residential Units](b)
Door,Hollow Metal:Insulated Metal,Swinging,[Bldg.Use 1 - 24 --- --- 0.370 0.370
Residential Units]
South Louver:Wood-Framed, 16"o.c.,[Bldg.Use 1 -Residential Units] 2 0.0 0.0 0.292 0.064
South Metal Wrap:Wood-Framed, 16"o.c.,[Bldg.Use 1 -Residential 43 10.0 0.0 0.101 0.064
Units]
South Wall Non-Residential:Wood-Framed,16"o.c.,[Bldg.Use 2- 374 0.0 0.0 0.292 0.064
Other]
Window-Fiberglass Storefront:Wood Frame:Fixed,Perf.Specs.: 167 --- --- 0.340 0.310
Product ID Fiberglass Storefront System,SHGC 0.27,VT 0.64,[Bldg.
Use 2-Other](b)
South Wall Non-Residential-Louver:Wood-Framed, 16"o.c.,[Bldg. 2 0.0 0.0 0.292 0.064
Use 2-Other]
WEST
West Wall:Wood-Framed,16"o.c.,[Bldg.Use 1 -Residential Units] 5408 21.0 0.0 0.062 0.064
Window:Wood Frame:Fixed,Perf.Specs.:Product ID VPI Endurance, 1045 --- --- 0.260 0.310
SHGC 0.22,VT 0.51,[Bldg.Use 1 -Residential Units](b)
Window:Wood Frame:Operable, Perf.Specs.:Product ID VPI 630 --- --- 0.270 0.310
Endurance,SHGC 0.18,VT 0.51,[Bldg.Use 1 -Residential Units](b)
Window-Fiberglass Storefront:Wood Frame:Fixed,Perf.Specs.: 45 --- --- 0.340 0.310
Product ID Fiberglass Storefront System,SHGC 0.27,VT 0.64,[Bldg.
Use 1 -Residential Units](b)
Door,Hollow Metal:Insulated Metal,Swinging,[Bldg. Use 1 - 47 --- --- 0.370 0.370
Residential Units]
Door,Other(Overhead):Insulated Metal,Non-Swinging,[Bldg.Use 1 - 86 --- --- 0.102 0.310
Residential Units]
West Louvers:Wood-Framed, 16"o.c.,[Bldg.Use 1 -Residential Units] 41 0.0 0.0 0.292 0.064
West Concrete:Solid Concrete:8"Thickness,Normal Density,Furring: 53 --- 1.1 0.343 0.090
None,[Bldg.Use 1 -Residential Units]
West Metal Wrap:Wood-Framed, 16"o.c.,[Bldg.Use 1 -Residential 114 10.0 0.0 0.101 0.064
Units]
West Wall Non-Residential:Wood-Framed,16"o.c.,[Bldg.Use 2- 508 0.0 0.0 0.292 0.064
Other]
Window-Fiberglass Storefront:Wood Frame:Fixed,Perf.Specs.: 304 --- --- 0.340 0.310
Product ID Fiberglass Storefront System,SHGC 0.27,VT 0.64,[Bldg.
Use 2-Other](b)
Door,Alum Storefront: Insulated Metal,Swinging,[Bldg.Use 2-Other] 67 --- --- 0.450 0.370
(a) Budget U-factors are used for software baseline calculations ONLY,and are not code requirements.
(b) Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation.
Envelope PASSES: Design 1%better than code
Envelope Compliance Statement
Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application.The proposed envelope systems have been
designed to meet the 90.1 (2016) Standard requirements in COMcheck Version 4.1.5.3 and to comply with any applicable
Project Title: Tigard Senior Housing Report date: 09/15/21
Data filename: P:\Architecture\1903070\C-Design Coordination\Jurisdictional\ComCheck\Tigard Senior Page 2 of 12
Housing.cck
mandatory requirements listed in the Inspection Checklist.
Name-Title Signature Date
Project Title: Tigard Senior Housing Report date: 09/15/21
Data filename: P:\Architecture\1903070\C-Design Coordination\Jurisdictional\ComCheck\Tigard Senior Page 3 of 12
Housing.cck
COMcheck Software Version 4.1.5.3
11(111
Inspection Checklist
Energy Code: 90.1 (2016) Standard
Requirements: 0.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section
# Plan Review Complies? Comments/Assumptions
& Req.ID
4.2.2, Plans and/or specifications provide all ❑Complies
5.4.3.1.1, information with which compliance ❑Does Not
5.7 can be determined for the building
WRITenvelope and document where pilot Observable
exceptions to the standard are ❑Not Applicable
claimed.
4.2.2, Plans, specifications, and/or ❑Complies
8.4.1.1, calculations provide all information ❑Does Not
8.4.1.2, with which compliance can be
8.7 determined for the electrical systems ❑Not Observable
[PR6]2 and equipment and document where ❑Not Applicable
exceptions are claimed. Feeder
connectors sized in accordance with
approved plans and branch circuits
sized for maximum drop of 3%.
5.5.4.2.3 In buildings > 2,500 ft2, any enclosed ❑Complies
[PR7]2 spaces directly under a roof with ❑Does Not
ceiling heights > 15 ft. and used as an
office, lobby, atrium, concourse, ❑Not Observable
corridor, storage(including ❑Not Applicable
nonrefrigerated warehouse),
gymnasium,fitness/exercise area,
playing area, gymnasium seating
area,convention exhibit/event space,
courtroom, automotive service,fire
station engine room, manufacturing
corridor/transition and bay areas,
retail, library reading and stack areas,
distribution/sorting area,
transportation baggage and seating
areas, or workshop,the following
requirements apply:The daylight zone
under skylights is >= half the floor
area and (a)the skylight area to
daylight zone is >= 3 percent with a
skylight VT>= 0.40 or(b)the
minimum skylight effective aperture
>= 1 percent.The skylights have a
measured haze value > 90 percent.
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Tigard Senior Housing Report date: 09/15/21
Data filename: P:\Architecture\1903070\C-Design Coordination\Jurisdictional\ComCheck\Tigard Senior Page 4 of 12
Housing.cck
Section Footing /Foundation Plans Verified Field Verified
# Inspection Value I Value Complies? Comments/Assumptions
& Req.ID i
4.2.4 Installed below-grade wall R- R- ❑Complies See the Envelope Assemblies
[FO1]2 insulation type and R-value ❑Does Not table for values.
consistent with insulation
specifications reported in plans []Not Observable
and COMcheck reports. ❑Not Applicable
1 4.2.4 Installed slab-on-grade insulation R- R- ❑Complies See the Envelope Assemblies
f [FO3]2 type and R-value consistent with ❑ Unheated ❑ Unheated ❑Does Not table for values.
insulation specifications reported ❑ Heated ❑ Heated ❑Not Observable
in plans and COMcheck reports.
❑Not Applicable
5.5.3.5 Slab edge insulation __ft ft ❑Complies See the Envelope Assemblies
[FO5]2 depth/length. ❑Does Not table for values.
ii ❑Not Observable
❑Not Applicable
5.8.1.7 Exterior insulation protected ❑Complies
[FO6]1 against damage, sunlight, ❑Does Not
moisture, wind, landscaping and
equipment maintenance Not Observable
activities. ❑Not Applicable
5.8.1.7.3 Insulation in contact with the �'� ❑Complies
[FO7]1 ground has <=0.3%water ❑Does Not
absorption rate per ASTM C272.
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
i
1
1
1
f
I
I
I 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Tigard Senior Housing Report date: 09/15/21
Data filename: P:\Architecture\1903070\C-Design Coordination\Jurisdictional\ComCheck\Tigard Senior Page 5 of 12
i Housing.cck
I
1
Section Plans Verified Field Verified
# Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions
& Req.ID
5.4.3.2 Factory-built and site-assembled ❑Complies
[FR1]3 fenestration and doors are ❑Does Not
labeled or certified as meeting air ❑Not Observable
leakage requirements. a , �'�
❑Not Applicable
5.4.3.4 Vestibules are installed where ❑Complies
[FR4]3 building entrances separate �� x'` ❑Does Not
conditioned space from the
exterior,and meet exterior ❑Not Observable
envelope requirements. Doors ❑Not Applicable
have self-closing devices, and are
>=7 ft apart(>= 16 ft apart for
adjoinging floor area >= 40000
sq.ft.). Vestibule floor area <=7
50 sq.ft. or 2 percent of the
adjoining conditioned floor area.
5.5.4.3a Vertical fenestration U-Factor. U- U- ❑Complies See the Envelope Assemblies
[FR8]1 ❑Does Not table for values.
❑Not Observable
❑Not Applicable
5.5.4.3b Skylight fenestration U-Factor. U- U- ❑Complies See the Envelope Assemblies
[FR9]1 ❑Does Not table for values.
❑Not Observable
❑Not Applicable
5.5.4.4.1 Vertical fenestration SHGC value. SHGC: SHGC: ❑Complies See the Envelope Assemblies
[FR10]1 ❑Does Not table for values.
❑Not Observable
❑Not Applicable
5.5.4.4.2 Skylight SHGC value. SHGC: SHGC: ❑Complies See the Envelope Assemblies
[FR11]1 ElDoes Not table for values.
[Not Observable
❑Not Applicable
5.8.2.1, Fenestration products rated (U ❑Complies
5.8.2.3, factor, SHGC, and VT) in ❑Does Not
5.8.2.4, accordance with NFRC or energy
5.8.2.5 code defaults are used. ['Not Observable
IFR12]2 ❑Not Applicable
5.8.2.2 Fenestration and door products ❑Complies
[FR13]1 are labeled,or a signed and ❑Does Not
dated certificate listing the U-
factor, SHGC,VT, and air leakage ['Not Observable
rate has been provided by the ❑Not Applicable
manufacturer.
5.5.3.6 U-factor of opaque doors U- U- ❑Complies See the Envelope Assemblies
[FR14]2 associated with the building ❑ Swinging ❑ Swinging ❑Does Not table for values.
thermal envelope meets ❑ Nonswinging ❑ Nonswinging ❑Not Observable
requirements.
❑Not Applicable
5.4.3.1 Continuous air barrier is ❑Complies
[FR15]1 wrapped,sealed, caulked, ❑Does Not
gasketed, and/or taped in an
approved manner, except in ❑Not Observable
semiheated spaces in climate ❑Not Applicable
zones 1-6.
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2, Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Tigard Senior Housing Report date: 09/15/21
Data filename: P:\Architecture\1903070\C-Design Coordination\Jurisdictional\ComCheck\Tigard Senior Page 6 of 12
Housing.cck
r y
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Tigard Senior Housing Report date: 09/15/21
Data filename: P:\Architecture\1903070\C-Design Coordination\Jurisdictional\ComCheck\Tigard Senior Page 7 of 12
Housing.cck
Section
# Rough-In Electrical Inspection Complies? Comments/Assumptions
& Req.ID1
8.4.2 At least 50%of all 125 volt 15-and ❑Complies
[EL10]2 20-Amp receptacles are controlled by ❑Does Not
an automatic control device.
❑Not Observable
❑Not Applicable
8.4.3 New buildings have electrical energy ❑Complies
[EL11]2 use measurement devices installed. ❑Does Not
Where tenant spaces exist, each
tenant is monitored separately. In ❑Not Observable
buildings with a digital control system ❑Not Applicable
the energy use is transmitted to to
control system and displayed
graphically.
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Tigard Senior Housing Report date: 09/15/21
Data filename: P:\Architecture\1903070\C-Design Coordination\Jurisdictional\ComCheck\Tigard Senior Page 8 of 12
Housing.cck
Sections I Plans Verified Field Verified
# Insulation Inspection Complies? , Comments/Assumptions
&Req.ID Value Value i
4.2.4 Installed roof insulation type and R- R- EComplies See the Envelope Assemblies
[IN2]1 R-value consistent with insulation ❑ Above deck ❑ Above deck ❑Does Not table for values.
specifications reported in plans ❑ Metal ❑ Metal ❑Not Observable
and COMcheck reports. For some Attic
ceiling systems,verification may ❑ Attic ❑ ENot Applicable
need to occur during Framing
Inspection.
5.8.1.2, Roof insulation installed per ❑Complies
5.8.1.3 manufacturer's instructions. ❑Does Not
[IN3]1 Blown or poured loose-fill
insulation is installed only where ❑Not Observable
the ceiling slope is <= 3:12. Observable_
Applicable
4.2.4 Installed above-grade wall R- R- ❑Complies See the Envelope Assemblies
[IN6]1 insulation type and R-value ❑ Mass ❑ Mass ❑Does Not table for values.
consistent with insulation ❑ Metal ❑ Metal ['Not Observable
specifications reported in plans
and COMcheck reports. ❑ Steel ❑ Steel ❑Not Applicable
❑ Wood ❑ Wood
5.8.1.2 Above-grade wall insulation ❑Complies
[IN7]1 installed per manufacturer's ❑Does Not
instructions.
['Not Observable
❑Not Applicable
4.2.4 Installed floor insulation type and R- R- ❑Complies See the Envelope Assemblies
[IN8]2 R-value consistent with insulation ❑ Mass ❑ Mass ❑Does Not table for values.
specifications reported in plans ❑ Steel ❑ Steel ❑Not Observable
and COMcheck reports.
❑ Wood ❑ Wood ❑Not Applicable
5.8.1.1 Building envelope insulation is ❑Complies
[IN10]2 labeled with R-value or insulation ❑Does Not
l certificate has been provided
listing R-value and other relevant ❑Not Observable
1 data. ❑Not Applicable
I
5.8.1.9 Building envelope insulation ❑Complies
l [IN18]2 extends over the full area of the ❑Does Not
1 component at the proposed rated
i R or U value. ❑Not Observable
I ❑Not Applicable
15.8.1.4 Eaves are baffled to deflect air to ❑Complies
/ [IN11j2 above the insulation. ❑Does Not
! ❑Not Observable
❑Not Applicable
5.8.1.5 Insulation is installed in ❑Complies
[IN12]2 substantial contact with the ❑Does Not
inside surface separating
conditioned space from ['Not Observable
unconditional space. ❑Not Applicable
5.8.1.6 Recessed equipment installed in ❑Complies
[IN13]2 building envelope assemblies ❑Does Not
does not compress the adjacent
insulation. ❑Not Observable
❑Not Applicable
5.8.1.7.1 Attics and mechanical rooms ❑Complies
[IN15]2 have insulation protected where ❑Does Not
adjacent to attic or equipment
8 access. ❑Not Observable
❑Not Applicable
i
i
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Tigard Senior Housing Report date: 09/15/21
Data filename: P:\Architecture\1903070\C-Design Coordination\Jurisdictional\ComCheck\Tigard Senior Page 9 of 12
Housing.cck
Section Insulation Inspection Plans Verified Field Verified
& Re ID p Value Value
q. Complies? Comments/Assumptions
5.8.1.7.2 Foundation vents do not interfere ❑Complies
[IN16]2 with insulation. ❑Does Not
❑Not Observable
❑Not Applicable
5.8.1.8 Insulation intended to meet the ❑Complies
[IN17]3 roof insulation requirements ❑Does Not
cannot be installed on top of a
suspended ceiling. Mark this ❑Not Observable
requirement compliant if ❑Not Applicable
insulation is installed accordingly.
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 'Low Impact(Tier 3)
Project Title: Tigard Senior Housing Report date: 09/15/21
Data filename: P:\Architecture\1903070\C-Design Coordination\Jurisdictional\ComCheck\Tigard Senior Page 10 of 12
Housing.cck
Section
# ; Final Inspection Complies? Comments/Assumptions
& Req.ID
5.4.3.3 Weatherseals installed on all loading ❑Complies
[Fill' dock cargo doors in Climate Zones 4- ❑Does Not
8. ❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 I Low Impact(Tier 3)
Project Title: Tigard Senior Housing Report date: 09/15/21
Data filename: P:\Architecture\1903070\C-Design Coordination\Jurisdictional\ComCheck\Tigard Senior Page 11 of 12
Housing.cck
•
Project Title: Tigard Senior Housing Report date: 09/15/21
Data filename: P:\Architecture\1903070\C-Design Coordination\Jurisdictional\ComCheck\Tigard Senior Page 12 of 12
Housing.cck
COMcheck Software Version COMcheckWeb
inft Interior Lighting Compliance CertifiRfe EIV
ED
SEP 2 3 2021
Project Information CITY OF TIGARD
Energy Code: 90.1 (2016) Standard
BUILDING DIVISION
Project Title: Tigard Senior Housing
Project Type: New Construction
Construction Site: Owner/Agent: Designer/Contractor:
8803 SW OMARA ST
TIGARD, OR 97223
Ailowea interior Lighting Power
A B C D
Area Category Floor Area Allowed Allowed
(ft2) Watts /ft2 Watts
1-Senior Housing (Multifamily) 47679 0.68 32422
Total Allowed Watts = 32422
Proposed Interior Lighting Power
A B C D E
Fixture ID : Description / Lamp /Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D)
Fixture Fixture Watt.
1-Senior Housing (Multifamily)
LED: 51: LED Downlight: LED Other Fixture Unit 16W: 1 426 16 6603
LED: 54: LED Linear: LED Linear 11W: 1 3 11 32
LED: 55: LED Linear: LED Linear 11W: 1 3 11 32
LED: 56: LED Linear: LED Other Fixture Unit 50W: 1 48 50 2400
LED: R1: LED Recessed: LED PAR 18W: 1 22 18 396
LED: R2: LED Recessed: LED MR 2W: 1 6 2 13
LED: P1: Pendant: LED Other Fixture Unit 50W: 1 6 50 300
LED: P3: Pendant: Other: 1 1 480 480
LED: Fl: LED FAN LIGHT: LED Other Fixture Unit 25W: 1 58 66 3828
LED: V1: LED Vanity: LED Other Fixture Unit 16W: 1 58 16 928
LED: V2: LED Vanity: LED Other Fixture Unit 28W: 1 4 30 120
LED: W4: LED Sconce: LED Other Fixture Unit 6.5W: 1 4 4 16
LED: X1: LED Exit Sign: LED Other Fixture Unit 6.5W: 1 21 4 84
Total Proposed Watts = 15231
ntenor Lighting PASSES: Design 53%better than code
Interior Lighting Compliance
Statement
Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been
designed to meet the 90.1 (2016) Standard requirements in COMcheck Version COMcheckWeb and to comply with any applicable
mandatory requirements listed in the Inspection Checklist.
Name-Title Signature Date
Project Title: Tigard Senior Housing Report date: 09/14/21
Data filename: Page 1 of 6
,
COMcheck Software Version COMcheckWeb
iftrif
444/111 Exterior Lighting Compliance Certificate
Project Information
Energy Code: 90.1 (2016) Standard
Project Title: Tigard Senior Housing
Project Type: New Construction
Exterior Lighting Zone 2 (Residential mixed use area (LZ2))
Construction Site: Owner/Agent: Designer/Contractor:
8815 SW Omara St '
Tigard, Oregon 97223
Allowed Exterior Lighting Power
A B C D E
Area/Surface Category Quantity Allowed Tradable Allowed Watts
Watts / Wattage (B X C)
Parking only(Parking area) 29000 ft2 0.04 Yes 1160
Egress Sidewalk(Walkway < 10 feet wide) 700 ft of 0.5 Yes 350
(4) 3' Exterior doors (Pedestrian and vehicular entrances and exits) 12 ft of 14 Yes 168
Stairs on Driveway side (Stairway) 175 ft2 0.7 Yes 122
Total Tradable Watts (a) = 1800
Total Allowed Watts = 1800
Total Allowed Supplemental Watts(b) = 400
(a)Wattage tradeoffs are only allowed between tradable areas/surfaces.
(b)A supplemental allowance equal to 400 watts may be applied toward compliance of both non-tradable and tradable
areas/surfaces.
Proposed Exterior Lighting Power
A B C D E
Fixture ID : Description / Lamp /Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D)
Fixture Fixture Watt.
Parking only (Parking area. 29000 ft2): Tradable Wattage
LED: G1, G3: LED Pole Light Fixture: LED Roadway-Parking Unit 130W: 1 7 155 1085
Egress Sidewalk (Walkway < 10 feet wide, 700 ft of walkway length): Tradable Wattage
LED: W: LED Wall Pack: LED Other Fixture Unit 28W: 1 12 30 360
LED: G3: LED Pole Light Fixture: LED Roadway-Parking Unit 130W: 1 1 155 155
(4) 3' Exterior doors (Pedestrian and vehicular entrances and exits. 12 ft of door width): Tradable Wattage
LED: G5: LED Post Top: LED Roadway-Parking Unit 67W: 1 4 71 284
Stairs on Driveway side (Stairway. 175 ft2): Tradable Wattage
LED: G4: LED Pole Light Fixture: LED Roadway-Parking Unit 130W: 1 1 155 155
Total Tradable Proposed Watts = 2039
Exterior Lighting PASSES: Design 7% better than code
Exterior Lighting Compliance
Statement
Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application.The proposed exterior lighting systems have been
designed to meet the 90.1 (2016) Standard requirements in COMcheck Version COMcheckWeb and to comply with any applicable
mandatory requirements listed in the Inspection Checklist.
Project Title: Tigard Senior Housing Report date: 09/14/21
Data filename: Page 2 of 6
Name-Title Signature Date
1
Project Title: Tigard Senior Housing Report date: 09/14/21
Data filename: Page 3 of 6
(1.6 COMcheck Software Version COMcheckWeb
11 Inspection Checklist
Energy Code: 90.1 (2016) Standard
Requirements: 100.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section
# Plan Review Complies? Comments/Assumptions
& Req.ID
4.2.2, Plans, specifications, and/or ❑Complies Requirement will be met.
9.4.3, 9.7 calculations provide all information ❑Does Not
[PR4]1 with which compliance can be
determined for the interior lighting ❑Not Observable'.
and electrical systems and equipment ❑Not Applicable
and document where exceptions to
the standard are claimed. Information
provided should include interior
lighting power calculations,wattage of
bulbs and ballasts, transformers and
control devices.
9.7 Plans, specifications, and/or ❑Complies Requirement will be met.
[PR8]1 calculations provide all information ❑Does Not
with which compliance can be
determined for the exterior lighting ❑Not Observable'.
and electrical systems and equipment ❑Not Applicable
and document where exceptions to
the standard are claimed. Information
provided should include exterior
lighting power calculations,wattage of,
bulbs and ballasts,transformers and
control devices.
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 `Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Tigard Senior Housing Report date: 09/14/21
Data filename: Page 4 of 6
Section
# Rough-In Electrical Inspection Complies? Comments/Assumptions
& Req.ID __ E
9.4.1.1 Automatic control requirements ❑Complies Requirement will be met.
[EL1)2 prescribed in Table 9.6.1,for the ❑Does Not
appropriate space type,are installed.
Mandatory lighting controls(labeled ❑Not Observable
as 'REQ')and optional choice controls ❑Not Applicable
(labeled as 'ADD1'and 'ADD2') are
implemented.
9.4.1.1 Independent lighting controls installed ❑Complies Requirement will be met.
[EL2F per approved lighting plans and all ❑Does Not
manual controls readily accessible and
visible to occupants. [Not Observable
❑Not Applicable
9.4.1.1f Daylight areas under skylights and ❑Complies Requirement will be met.
[EL13]1 roof monitors that have more than ❑Does Not
150 W combined input power for
general lighting are controlled by [Not Observable
photocontrols. ❑Not Applicable
9.4.1.4 Automatic lighting controls for exterior ❑Complies Requirement will be met.
[EL3)z lighting installed. ❑Does Not
ENot Observable
❑Not Applicable
9.4.1.4d Outdoor parking area luminaires >= EComplies Requirement will be met.
[EL21]2 78W and <= 24 ft height controlled to ❑Does Not
reduce wattage by 50%when area
unoccupied over 15 minutes. ['Not Observable
Controlled power limited to <_ ❑Not Applicable
1500W.
9.4.1.3 Separate lighting control devices for ❑Complies Requirement will be met.
[EL4]1 specific uses installed per approved ❑Does Not
lighting plans.
❑Not Observable
❑Not Applicable
9.6.2 Additional interior lighting power ❑Complies Requirement will be met.
[EL8]1 allowed for special functions per the ❑Does Not
approved lighting plans and is
automatically controlled and Not Observable
separated from general lighting. ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Tigard Senior Housing Report date: 09/14/21
Data filename: Page 5 of 6
Section
Final Inspection Complies? Comments/Assumptions
& Req.ID
8.7.1 Furnished as-built drawings for ❑Complies Requirement will be met.
[F116]3 electric power systems within 30 days ❑Does Not
of system acceptance.
['Not Observable
❑Not Applicable
8.7.2 Furnished O&M instructions for ❑Complies Requirement will be met.
[F117]3 systems and equipment to the ❑Does Not
building owner or designated
representative. Not Observable
❑Not Applicable
9.2.2.3 Interior installed lamp and fixture ❑Complies See the Interior Lighting fixture schedule for values.
[FI18]1 lighting power is consistent with what LiDoes Not
is shown on the approved lighting
plans, demonstrating proposed watts ❑Not Observable'.
are less than or equal to allowed ❑Not Applicable
watts.
9.4.2 Exterior lighting power is consistent ❑Complies See the Exterior Lighting fixture schedule for values.
[FI19]1 with what is shown on the approved ❑Does Not
lighting plans, demonstrating
proposed watts are less than or equal ❑Not Observable
to allowed watts. ❑Not Applicable
9.4.4 At least 75%of all permanently ❑Complies Requirement will be met.
[F120]1 installed lighting fixtures in dwelling ❑Does Not
units have >= 55 Im/W efficacy or a
>= 45 Im/W total luminaire efficacy. ❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Tigard Senior Housing Report date: 09/14/21
Data filename: Page 6 of 6