Loading...
Report I `Job Name:Don Penn IL (U'a'~ `.0" '3 I TMPIE. Prepared BpWQt.E-1 v F "i / "l sW i . 4vQuantil , 5 ' Variable Air Volume Single Duct sl (1 1 Unit model Primary inlet Design cooling airflow Min cooling airflow Trane Supplied o;• `» •" VCEF(Electric Heating) 14"(356mm) 1800 cfm 420 cfm Refer to"Customer Supplied" controls APD @ cooling airflow 0.010 in H2O Cooling inlet velocity 1684 fUmin Valve heating airflow 800 cfm Unit Insulation 1"matte Elevation 0.00 ft ---✓ Operating weight 60.0 lb ->",., Air Leakage Class Standard Air Leakage c I . / Jt 0 Yfi r. i P . ECEIVEC „,, # APR 2 6 2021 CITY OF TIGARI Full load amps 16.65 A Primary EDB 55.00 F Max fuse size 25.00 A Room heating setpoint 68.00 F Min circuit ampacity 20.82 A Room heat loss 9.21 MBh Unit LAT 78.61 F Coil heating capacity 20.49 MBh Electric heater voltage 208/3 Customer supplied controls/No Shaft only-with control enclosure Electric heater kilowatt 6.0 controls Electric heater stage 2 Electric heater control 24 volt magnetic contactors Disconnect Switch Disconnect switch Transformer 208/24 volt transformer Max inlet SP Discharge transfer function Radiated transfer function 0.750 in H2O AHRI 885-98/08 AHRI 885-98/08 Mineral Fiber Sound Path 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz NC Discharge valve 74 dB 66 dB 62 dB 57 dB 50 dB 47 dB 26 Radiated valve 64 dB 58 dB 49 dB 43 dB 36 dB 36 dB 27 — Miff" Job Name:Don Penn Prepared By Unit Tag.SINGLE-1 Quantity:1 • 3 1/4"+' 14" t {. AIR VALVE AIR FLOW 45" \ ELECTRIC NEATER 421t2" \\ CONTROLS AREA 31" UNIT CONTROLS AREA Y I _ t" C Customer Notes 26 1(2" SLIP&DRIVE 1 Air Inlet is centered in unit front panel. CONNECTION TOP VIEW 2 Slip&Drive discharge outlet standard ---- --- 3 Minimum of 1.5 times duct diameter of straight duct at inlet for proper flow reading. 4 For electric heater access,side hinged door must have minimum distance per NEC or local code 5 Allow 48"of straight duct downstream of unit before first runoff!&inside of the duct should be equal discharge size(A&B) 6 Left-hand onentatian shown.(Facing discharge) 11 1/2" 18" 19112" Unit can be flipped to right-hand orientation • • • Approximate 600tb 4- 1 Dry Weight • 19" t Weights reflected may vary 1.0— s" 20 ter ±5.0 lb based upon options selected. BACK VIEW 2021-04-20 22:31:42Z Page 2 of 4 Job Name:Don Penn • Irmo- Prepared By' Unit Tag SINGLE-1 Quantity:1 • . ' • 208 Volt,3 Phase L3 12 Li LG ill _41 Heater Controls Wiring 2021-04-20 22:31:42Z Page 3 of 4 Job Name:Dorm Penn • Prepared By: Unit Tag:SINGLE-1 Quantity:I •I ` FROM ELECTRIC HEATER NOTES 1. FACTORY WRING EL V - -FIELD WRING —--—--—OPTIONAL OR ALTERNATE WRING 2 ALL FIELD WRING MUST BE IN ACCORDANCE WIN THE NATI CNAL ELECTRIC CODE(NEC),STATE AND LOCAL REQUIREMENTS. 3 UNITS WITH ELECTRIC HEAT HAVE OPTIONAL DISCONNECT SWITCH,FUSE AND TRANSFORMER LOCATED IN HEATER. 8K `7T 6 i I � � 24VAC POWER BL(24VAC) TO VAV , 3RD STAGE HEAT _ RED CONTROLLER FROM ELECTRIC 2ND STAGE HEAT _ VIO STAGED HEATER CONTRACTORS RE 24VAC HCONTROL ELECTRIC I2VAMAX1COIL(MERCURY CONTACTORS). HEATER 10VA MAX/COIL(MAGNETIC CONTACTORS). 1ST STAGE HEAT ORN COM BR 2021-04-20 22:31:42Z Page 4 of 4