Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report (3)
Oregon Residential Specialty Code R318.2 MOISTURE CONTENT ACKNOWLEDGEMENT FORM I, ld a,w.ty 130L0s1 , am the general contractor or the owner-builder at the following address: Site Address: 124 y? 5W , i 4L,k h. City: / i,Yii Permit#: /"lsf2vzi- ova s- ! Subdivision/Lot #: -you) and/or Map and Tax Lot#: To conform with the 2017 Oregon Residential Specialty Code (ORSC), Section R318.2 and OAR 918-480-0140, I am notifying the building official that 1 am aware of the moisture content Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement. [Section R318.2 is provided for reference]. R318.2 Moisture Content: Prior to the installation of interior finishes, the building official shall be notified in writing by the general contractor that all moisture-sensitive wood framing members used in construction have a moisture content of not more than 19 percent by dry weight of dry framing members. Signature: "3,....__ 31Date: y/26 A Z General Contractor or Owner-Builder I:\Building\Form\RFS-MoistureContentAcknowledgement_022018 Oregon Residential Specialty Code R408.1 MOISTURE BARRIER ACKNOWLEDGEMENT FORM I, /3uj_.if,,:, , am the general contractor or the owner-builder at the following address: Site Address: L27q? 5G1 PieJfnrivk City: Permit#: flsf2oz! -ova r1 Subdivision/Lot #: 'fa ZD and/or Map and Tax Lot #: To conform with the 2017 Oregon Residential Specialty Code (ORSC), Section R408.1 Ventilation. 1 am notifying the building official that 1 have installed the Moisture Barrier as per Requirement in ORSC Section 408.1 and have taken the following steps to meet this code requirement: V The ground surface of the under-floor space is covered by a Class I vapor retarder or other approved materials, with 14 /Joints lapped 12 inches at seams and Extending up the foundation walls 12 inches. Signature: gseL Date: WZt/2Z General Contractor or Owner-Builder I:ABuilding\Form\RES-MoistureBarrierAcknowledgement_022018 Oregon Residential Specialty Code N1107.2 HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS Permit No.: AI(6LZO1I -OOo r` Jurisdiction: _ / Site Address: 1Zti/et St..) /4C4.244Jv k 1.. Subdivision/Lot#: `JIVED and/or Map and Tax Lot #: i By my signature below, I certify that all of the permanently installed lighting fixtures in the above mentioned building contain high-efficacy lamps. Screw-in compact fluorescent and LED lamps comply with this requirement. (Oregon Residential Specialty Code NI 107.2)1 Signature: Date: 04/22- Owner/General Contractor/Authorized Agent Print Name: /3c- av ,r ORSC Section N1107.2. High-efficacy lamps. All permanently installed lighting fixtures shall contain high- efficacy lamps. Screw-in compact fluorescent and LED lamps comply with this requirement. The building official shall be notified in writing at the final inspection that the permanently installed lighting fixtures have met this requirement. Exception: Two permanently installed lighting fixtures are not required to have high-efficacy lamps. I:\Building\Forms\RES-I IighEt'ticiencyLightingAcknowledgement_022018 Form 640S 2017 Completion Certification—Site Inspection Engrg rTrust New Homes Program—Single Family ,�j J of Oregon To be completed by Verifier CLEAResult is a Program Management Contractor for Energy Trust of Oregon,Inc. Payment Information Incentive Payee Company Name: 'Performance Insulation and Energy I Is this payment redirected?: Ives Builder or Company: Polygon Northwest-WA Redirect to Name: Verifier Payee Company Name: Performance Insulation and Energy Redirect Payee Com Performance Insulation and Energy Affordable Housing No Solar Ready Builder Incentive: No 'Solar ReadyVerifier Ince'No Site Information Development: 3C EAST RIDGE CRESCENT TH ILo! 120 Axis ID: I 'REM/Rate®ID'. Address: 12949 SW MEADBROOK LN Street Line 2 Multi-Family I No City: PORTLAND State: OR Zip: 97229 Total conditioned area(sq.fit.): 1,908 House Volume: I 23,000 Housing Type: Townhouse end Number of Stories: 14 Number of Bedrooms: 3 Foundation Type: Slab Floor Electric Provider Portland General Electric Gas Provider NW Natural Gas Solar installed None Solar Installer Name/Company: • • Blue shaded fields are required for EPS sheet Verification Type Actual Model Equipment Details&Notes • Slab Perimeter Insulation R- Slab Under Insulation R- ,. InsulationFramed Floor R- 30.0 Secondary Framed Floor R- Above Grade Wall Insulation R- 23 Below Grade Wall Insulation R- Flat Ceiling Insulation R- 49.0 Vaulted Ceiling Insulation R- Windows Windows U- 0.3 SHGC:10.3 Total window area: Cooling Air Conditioning SEER: 0 Model#: Primary Heating System Details AFUE: 95 Brand Lennox Type: Gas Furnace HSPF: Model it: ML196UH045XE36B-51 Heating Fuel: Gas SEER: Primary Heat Source Comment COP: Location: Attic Outdoor Unit(for heat pumps) ECM: No Model#: I AHRI Certificate:4805339 #of Systems 11 Gallons: 166 Brand: AOSmith Water Heater Type Heat Pump EF: 13.17 Model#: HPTU-66N 130 Water Heating Fuel Electric Location: 'Garage or ope AHRI Certificate: Ducts and Duct Location 'Partial %ducts inside: 175%. !Duct Leakage(CFM)@ 50Pa: 1147 Testing Infiltration Air Changes per Hour(ACH)©50Pa: 4.75 I Ventilation Ventilation Type HRV/ERV Model: Supply Side-Air Cycler Airflow measured or why untestable? 'Roof Termination Appliances Refrigerator kWhyr Model: ENERGY STAR Diswasher kWhyr Model: GDF510PSR3SS Percent High Efficacy Interior Lighting(%) Thermostat Showerhead 1.5 GPH I I Showerhead 1.6 GPH I SShowerhead 1.75 GPH I Notes: ELlgavirosi:ittraii ft:2; Q'IiyW+4LL.,,.a �N',�+Ilr�..I►..��'pN Certificate of Compliance This document certifies that the fiberglass insulation has been installed in conformance with the manufacturer's recommendations and requirements to provide thermal resistance value(s)of: R-value Thickness Coverage Area Ceilings: R-49 X New Construction Vaults/Slopes: R-38 Walls: R-23 O Upgrade Blown in Rim Joist: Floors: Over Garage R-39 BIBS Crawl Vapor Barrier installed_Y _N Sprinkler Tenting 4 mil Poly Y _N Loose-Fill Insulation R-_using_bags of insulation to cover All Batts square feet of area at a thickness of 20 inches. Owens Corning'PROPINK'L77 Loosefill Insulation Owens Corning will accept no responsibility when the product is not installed in accordance with the product label.Stated R-value is provided by installing the required number ofbags at a thickness not less than the labeled minimum thickness.Installation ofthe required number ofbags may yield more than the specified minimum thickness.Failure by the installer to provide both the required bags and at least the minimum thickness will result in lower insulation R-value. R-VALUE BAGS PER MAXIMUM NET MINIMUM WEIGI-IT MINUMUM 1000 SQ.FT. COVERAGE PER SQ.FT. THICKNESS To obtain a No.of bags per 1000 sq. Contents of this bag Weight per sq.ft.of Installed insulation thermal resistance ft.of net area: should not cover installed insul.should should not be less (R)of: more than:(sq.ft.) not be less than:(lbs.) than:(in.) 60 28.0 35.8 0.895 20.00 49 22.2 45.0 0.711 16.75 44 19.7 50.7 0.631 15.00 38 16.7 59.9 0.534 13.2.5 30 13.0 77.0 0.416 10.50 26 11.2 89.6 0.357 9.25 22 9.4 106.3 0.301 8.00 19 8.0 125.0 0.256 7.00 13 5.4 184.6 0.173 4.75 Property Address: 12949 SW Meadbrook Ln, Tigard, OR. 97224 Lot 20 1/27/22 Carolina Jarquin Date of Installation Westside Drywall Inc.authorization 3/13/22 Today's Date Building Contractor's Signature Taylor Morrison Company/Customer Name P.O.BOX 99*HUBBARD,OR 97032*(503)620.7036*FAX(503)624-0599*CCB#71044