Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
DURHAM WRRF oFE COPY WOMEN 'S LOCKER ROOM REMODEL PROJECT TEAM PROJECT AREA 2 /` OWNER ARCHITECTURAL > 100 w % CLEAN WATER SERVICES RESOLVE ARCHITECTURE+PLANNING `7),, �o °� DURHAM AWWTP 3742 SE MILL ST. 16060 SW 85th AVE. PORTLAND,OR 97214 TIGARD,OR 97224 PH:503.939.5130 PH:503.547.8150 CONTACT:JOHN FLYNN .' „: ,s I CONTACT:DAN GARBELY �� • MECHANICAL/PLUMBING/ELECTRICAL SAZAN GROUP o riw-- illr 111 SW FIFTH AVE,SUITE 2120 - p- PORTLAND,OR 97204 -- PH:503.416.2400 •• ��r CONTACT:DANIEL TOUGER PROJECT AREA 3 I PROJECT AR SHEET INDEX ABBREVIATIONS _\ _ / GENERAL MECHANICAL AFF ABOVE FINISHED FLOOR GWB GYPSUM WALLBOARD \ g J) APPROX. APPROXIMATE HGHT HEIGHT C `7 G.1 COVER M.0 MECHANICAL NOTES,ABBREVIATIONS CLNG. CEILING LL LOT LINE \ G.2 ACCESSIBILITY DETAILS M.1 MECHANICAL SYMBOL LEGEND CLR CLEAR MAX. MAXIMUM M.2 HVAC DEMOLITION PLAN CO CARBON MONOXIDE MECH MECHANICAL �❑� r M.3 HVAC PLAN CONC. CONCRETE MIN. MINIMUM M.4 MECHANICAL SCHEDULES&DETAILS CONT CONTINUOUS N/S NORTH-SOUTH M.5 NEW OFFICE 101 MECHANICAL PLAN DBL DOUBLE O.C. ON CENTER DIA. DIAMETER OSB ORIENTED STRAND BOARD KEY PLAN DIM. DIMENSION PL PROPERTY LINE N ARCHITECTURAL (E) EXISTING PLWD. PLYWOOD EA. EACH PT PRESSURE TREATED PROJECT AREA 1 --WOMEN'S LOCKER ROOM REMODEL A.1 DEMO PLAN P.0 PLUMBING LEGEND,NOTES& E.N. EDGE NAIL REQ'D REQUIRED A.2 FLOOR PLAN&FINISH SCHEDULE ABBREVIATIONS EQUIP EQUIPMENT REV REVISION PROJECT AREA 2-- NEW OFFICE 101 A.3 REFLECTED CEILING PLAN&TOILET P.1 PLUMBING DEMOLITION PLAN EQUIV. EQUIVALENT SF SQUARE FEET PROJECT AREA 3-- MEWS LOCKER ROOM SHOWER VALVE REPLACEMENT ACCESSORIES SCHEDULE P.2 PLUMBING WASTE&VENT PLAN E/W EAST-WEST T.C. TOP OF A.4 INTERIOR ELEVATIONS P.3 PLUMBING DOMESTIC WATER PLAN FIN. FINISHED T.O.CONC.TOP OF CONCRETE A.5 SECTIONS&DETAILS P.4 PLUMBING SCHEDULE&DETAILS FIN.FL. FINISHED FLOOR U/S UNDERSIDE A.6 NEW OFFICE 101 PLAN&ELEVATIONS F.N. FIELD NAIL W/ WITH RECEIVE EC E k- A.7 NEW OFFICE 101 DETAILS �� lI A.8 SPECIFICATIONS ELECTRICAL A.9 SPECIFICATIONS E.0 ELECTRICAL LEGEND,NOTES& GENERAL NOTES q q q ABBREVIATIONS DECC I v ZQ2, E" E.1 ELECTRICAL SYMBOLS LEGEND A. FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO PROCEEDING WITH THE H. LOCATE EXISTING UTILITIES WHETHER INDICATED OR NOT AND PROTECT FROM DAMAGE. .1 E.2 ELECTRICAL DEMOLITION WORK. CONTRACTOR SHALL AR REPAIR OR PLACEMENT ES F UTILITIES OR z E.3 ELECTRICAL POWER PLANP�N B. DIMENSIONS TAKE PRECEDENCE OVER DRAWINGS. DO NOT SCALE DRAWINGS. NOTIFY PROPERTY DAMAGED BY OPERATIONS INECONJUNCT ON WITH THEOPROSECUTIONJOng ^CF TIGKI ¢J E.4 LIGHTING PLAN ARCHITECT OF DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. WORK. F,3UU LLDDII!'JG DIVISI( ". a E.5 NEW OFFICE 101 ELECTRICAL PLAN C. CONTRACTOR IS SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS AND METHODS AND SHALL I. PROVIDE ACCESS PANELS AS REQUIRED.LOCATION,FINISH,AND TYPE SHALL BE APPROV�68Y gigi MAINTAIN THE STRUCTURAL INTEGRITY OF CONSTRUCTION UNTIL FINAL LATERAL AND ARCHITECT PRIOR TO OBTAINING AND INSTALLING.ACCESS PANEL LOCATIONS NOT APPROVED as VERTICAL CARRYING SYSTEMS IS COMPLETED. BY ARCHITECT WILL BE SUBJECT TO MODIFICATION AT NO ADDITIONAL COST TO OWNER OR a CITY OF TIGARD D. DIMENSIONS SHOWN ARE TO FACE OF STUD, FACE OF CONCRETE, FACE OF MASONRY, ARCHITECT. PROVIDE RATED ACCESS PANELS WITH THE SAME RATING AS THE ASSEMBLY IN a GRID/COLUMN LINE,CENTER OF ELEMENT,COUNTERTOP EDGE,OR AS NOTED. WHICH THEY ARE INSTALLED.ACCESS PANELS IN SHAFT WALLS, RATED FLOOR/CEILINGS OR m Approved EX1 E. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION AND COORDINATION OF SUBCONTRACTORS RATED ROOF CEILINGS SHALL BE SMOKE SEALED. Contitionally Approved I , WORK, COMPLIANCE WITH DRAWINGS AND SPECIFICATIONS, ACCURATE LOCATIONS OF J. ALL PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE FIRE STOPPED PER STRUCTURAL MEMBERS, OPENINGS FOR MECHANICAL, ELECTRICAL, AND MISCELLANEOUS SPECIFICATION SECTION 07 84 00-FIRESTOPPING AND THE AUTHORITY HAVING JURISDICTION'S E For only the work as described in: EQUIPMENT. CONTRACTOR SHALL VERIFY DIMENSIONS AND OPENING SIZES (CLEARANCES REQUIREMENTS. RATED ASSEMBLIES SHALL BE CONSTRUCTED TO PREVENT THE MOVEMENT r REQUIRED) FROM THE MANUFACTURERS PRIOR TO CONSTRUCTION OF OR INSTALLATION OF OF HOT FLAME OR GASES PER OSSC SECTION 709.6. PERMIT NO. PLrV ?Oa 1 -00. 1 *a EQUIPMENT,FURNISHING,AND ACCESSORIES. K. ALL SAFETY GLAZING SHALL BE PERMANENTLY LABELED WITH THE MANUFACTURERS NAME. O F. DETAILS NOTED AS "TYPICAL" OR "TYP" APPLY IN ALL CASES UNLESS SPECIFICALLY L. CONTRACTOR IS RESPONSIBLE FOR TRADE PERMITS, INCLUDING, BUT NOT LIMITED TO I' See Letter to: Follow I 1 REFERENCED. DETAILS THAT ARE SPECIFICALLY REFERENCED SHALL TAKE PRECEDENCE MECHANICAL, ELECTRICAL, AND EXTERIOR SIGNAGE. REFERENCED PERMITS SUMMARY ON ✓ OVER DETAILS NOTED AS "TYPICAL" OR "TYP". SPECIFIC NOTES AND DETAILS SHALL TAKE THIS SHEET. Iri Y Attacht. PRECEDENCE OVER GENERAL NOTES AND DETAILS. M. PROVIDE BACKING, BLOCKING, OR STRAPPING AS REQUIRED FOR MOUNTING GRAB BARS,Job Address: /Gr9 c s I ' IN Y V — Aye G. CONTRACTOR IS RESPONSIBLE FOR THE COMPLETE SECURITY OF THE SITE WHILE THE SHELVING,EQUIPMENT,HANDRAILS,ACCESSORIES,AND CASEWORKS. n PROJECT IS IN PROGRESS UNTIL PROJECT COMPLETION. o By: ,4GG1 Date: - N NI • a PROJ NAME'. SHEET TITLE: SHEET'. OF' DWG#: •� N DRN: DATE: i JOHN P FLYNN r ai H DSN: DWG E. RESOLVE DURHAM WRRF o°E, 10/25/21 /� w �4-g o THIS BAR IS ONE INCH RESOLVE COVER (v�; -I � P p N CHIC CAD FILE WHEN DRAWING IS FULL ARCHITECTURE + PLANNING WOMEN'S LOCKER ROOM `o SCALE. Our commitment is clear. N PLC#: ■ APPD: SCALE. REMODEL OF�p.YS•zl 0 REV# DATE DRN APPD DESCRIPTION 2550 SW Hillsboro Hwy. Hillsboro,Oregon 97123-9379 CWS PROJ# ENGR STAMP: GENERAL NOTES 16. MODIFY AND EXTEND EXISTING SERVICE TO ACCOMMODATE NEW WORK.RELOCATE ABBREVIATIONS EXISTING COMPONENTS AS REQUIRED FOR NEW SYSTEM.COORDINATE WITH SYMBOLS LEGEND-PIPING BUILDING MANAGEMENT. 1. THE SCOPE OF THE PLUMBING WORK CONSISTS OF WORK SHOWN ON THE PLANS AND SYMBOL DESCRIPTION AS DESCRIBED IN THE SPECIFICATIONS.IN CASE OF CONFLICT,THE SPECIFICATIONS 17. PROVIDE PRODUCTS OF ACCEPTABLE MANUFACTURERS,WHICH HAVE BEEN IN A AIR,AMP HWS HEATING WATER SUPPLY SHALL GOVERN.PROVIDE A COMPLETE 8 FUNCTIONAL SYSTEM. SATISFACTORY USE IN SIMILAR SERVICE FOR THREE YEARS.DELIVER,HANDLE,AND ACU AIR CONDITIONING UNIT HZ HERTZ SAN SOIL OR WASTE STORE MATERIALS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. TF ABOVE FINISHED FLOOR V VENT 2. PERFORM ALL WORK IN ACCORDANCE WITH LOCAL CODES AND ORDINANCES.OWNER AHU AIR HANDLING UNIT D NSIDE DIAMETER,INDIRECT DRAIN SAN RAIN LEADER TO OBTAIN AND PAY FOR ALL REQUIRED PERMITS AND PAY FOR ALL FEES REQUIRED 18. DO NOT CUT STRUCTURAL ELEMENTS WITHOUT PRIOR WRITTEN APPROVAL FROM AL ALUMINUM,ACOUSTICAL LINING E N ELEVATION ATMGT ARRANGEMENT H NTCAKE HOOD SAN OVERFLOW RAIN LEADER BY AUTHORITIES HAVING JURISDICTION.PAY ALL ROYALTIES OR FEES REQUIRED IN THE PROJECTS STRUCTURAL ENGINEER OF RECORD. ATM ATMOSPHERE N NCH DCW INDIRECT DRAIN CONNECTION WITH THE USE OF PATENTED DEVICES AND SYSTEMS. NIT NITIAL 19. CONCEAL PIPING AND DUCTWORK TO THE GREATEST EXTENT POSSIBLE. BC BLOWER COIL NT NTERIOR DCW COLD WATER 3. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR GENERAL BDD BACKDRAFT DAMPER PLV NTEGRATED PART LOAD VALUE DHW HOT WATER CONSTRUCTION INCLUDING LOUVERS,CONCRETE EQUIPMENT PADS,FLASHING 20. INSTRUCT OWNER IN PROPER OPERATION OF SYSTEMS. BFF BELOW FINISHED FLOOR --------- HOT WATER CIRCULATING DETAILS,ETC.REFER TO ARCHITECTURAL DRAWINGS FOR ROOM ELEVATIONS, BFP BACKFLOW PREVENTER KW KILOWATT DHW 140"POTABLE HOT WATER LOCATE MECHANICAL DEVICES SUCH AS TEMPERATURE SENSORS,HUMIDISTATS, 21. DRAWINGS DO NOT SHOW ALL OFFSETS WHICH MAY BE REQUIRED.MAKE OFFSETS BHP BRAKE HORSEPOWER KWH KILOWATT HOURS DHW 120"POTABLE HOT WATER PANELS,ETC.SO THAT THEY DO NOT CONFLICT WITH GENERAL CONSTRUCTION WITH FITTINGS USING THE LEAST ANGLE OF OFFSET POSSIBLE.DUCTWORK 8 PIPING BLDG BUILDING (WAINSCOT,DOOR HARDWARE,ETC.)NOR WITH ELECTRICAL SYSTEM(LIGHT SHALL BE ROUTED TO AVOID ALL STRUCTURAL SUPPORTS,AND COORDINATED WITH BOB BOTTOM OF BEAM L LENGTH SP FIRE SWITCHES,SPEAKERS,OUTLETS,ETC). WORK OF OTHER TRADES. BOD BOTTOM OF DUCT LAT LEAVING AIR TEMPERATURE SP SPRINKLER BOB BOTTOM OF STEEL LB POUND,LINEAR BAR SP STANDPIPE 4. COORDINATE WITH OTHER TRADES' 22. MATERIALS,METHODS,AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF BTUH BRITISH THERMAL UNITS PER HOUR LBS POUNDS DCW HIGH PRESSURE STEAM A. REFER TO ELECTRICAL DRAWINGS AND CONFIRM ELECTRICAL THE LATEST EDITION OF THE FOLLOWING CODES AS ADOPTED BY THE AUTHORITY LD LINEAR DIFFUSER CHARACTERISTICS SHOWN FOR MECHANICAL EQUIPMENT(VOLTAGE,PHASE,HZ, HAVING JURISDICTION. CAP CAPACITY LWT LEAVING WATER TEMPERATURE DCW HEATING WATER SUPPLY ETC).MATCHES THAT OF THE MECHANICAL EQUIPMENT PROVIDED. CC COOLING COIL DCW- HEATING WATER RETURN B. PROVIDE ADEQUATE CLEARANCE OF MECHANICAL WORK FROM ELECTRICAL OREGON PLUMBING SPECIALTY CODE CD CEILING DIFFUSER MAX MAXIMUM DCW- CHILLED WATER SUPPLY EQUIPMENT.MAINTAIN MINIMUM ACCESS OF 6-INCHES ABOVE CABLE TRAYSCFM CUBIC FEET PER MINUTE MBH THOUSAND BTU PER HOUR AND 1&INCHES TO THE SIDE OF CABLE TRAYS.CLEARANCE ABOVE CABLE TRAY OREGON STRUCTURALPANFPA 25,NFPA 291 (OSSC) CHR CHILLED WATER RETURN MCA MINIMUM CIRCUITAMPACIN DCW- CHILLED WATER RETURN SHOULD BE 112 THE WIDTH AND NOT LESS THAN 6-INCHES WHEN RUNNING NFPA 13,NFPA 24, 25,NFPA 291 CHS CHILLED WATER SUPPLY MD MANUAL DAMPER I. REDUCER,CONCENTRIC PARALLEL WITH CABLE TRAY.AND NOT LESS THAN 6-INCHES WHEN RUNNING CI CAST IRON MECH MECHANICAL -I.pCW WYE STRAINER WITH CAPPED HOSE END BLOWDOWN VALVE PERPENDICULAR TO THE CABLE TRAY. CLG CEILING,COOLING MFR MANUFACTURER 'Y`LY REMODEL CONSTRUCTION NOTES CNTFGL CENTRIFUGAL MIN MINIMUM 5, ARRANGE EQUIPMENT SO THAT ACCESS CLEARANCES INDICATED BY DRAWINGS, CO CLEANOUT MOCP MAXIMUM OVER CURRENT PROTECTION ANGLE VALVE REQUIRED BY CODES,OR RECOMMENDED BY MANUFACTURER ARE PROVIDED, CONC CONCRETE MOD MOTOR OPERATED DAMPER 1. DEMOLITION:WORK REQUIRED IS NOTED ON PLANS.VERIFY WITH ON SITE CONS CONDENSATE MTR MOTOR 6. INSTALL MATERIALS AND SYSTEMS IN ACCORDANCE WITH MANUFACTURER'S CONDITION AND OWNER.SALVAGE EQUIPMENT FOR OWNERS USE AS NOTED. CONT CONTINUE,CONTROL AUTOMATIC CONTROL VALVE-TWO WAY(PNEUMATIC OPERATOR SHOWN) INSTRUCTIONS AND ACCEPTED SUBMITTALS.INSTALL MATERIAL IN PROPER COMP COMPRESSOR NC NORMALLY CLOSED RELATION TO ADJACENT CONSTRUCTION AND WITH UNIFORM APPEARANCE FOR 2. COORDINATE INTERRUPTIONS OF SERVICES PASSING THROUGH WORK AREA TO COP COEFFICIENT OF PERFORMANCE NEG NEGATIVE EXPOSED WORK. MINIMIZE DISRUPTION IN ADJACENT SPACES.COORDINATE WITH BUILDING OWNER. CP CIRCULATING PUMP NIC NOT IN CONTRACT AUTOMATIC CONTROL VALVE-THREE WAY(ELECTRIC OPERATOR SHOWN) CRU CONDENSATE RETURN UNIT NO NUMBER,NORMALLY OPEN 7. THOROUGHLY EXAMINE ALL AREAS WHERE EQUIPMENT,DUCTWORK,AND PIPING WILL 3. INSTALL NEW WORK GENERALLY AS SHOWN.ADEQUATE SPACE HAS BEEN VERIFIED CU CONDENSING UNIT NTS NOT TO SCALE BE INSTALLED AND REPORT ANY CONDITION THAT PREVENTS THE PROPER TO THE DEGREE POSSIBLE,BUT MAY REQUIRE MINOR RELOCATION OF SMALL CU FT CUBIC FEET INSTALLATION OF THE MECHANICAL WORK. CONDUIT AND CEILING WIRE.COORDINATE EXTENT OF RELOCATION WITH GENERAL CV CONSTANT VOLUME OA OUTDOOR AIR �/1 BUTTERFLY VALVE CONSTRUCTION WORK. CVTR CONVERTER OC ON CENTER CW COLD WATER OD OUTSIDE DIAMETER FLEXIBLE CONNECTION IN PIPING 8. COMPLY WITH WASHINGTON STATE ENERGY CODE SECTION C408.1.3 4. COORDINATE WORK WITH GENERAL CONSTRUCTION TO MINIMIZE DUST 8 DUST OPNG OPENING DOCUMENTATION REQUIREMENTS INCLUDING ALL LOCAL JURISDICTION MIGRATION. dB DECIBELS ORD OVERFLOW ROOF DRAIN AMENDMENTS.INCLUDE THE DEVELOPMENT OF CONSTRUCTION AND AS-BUILT DB DRY BULB ORL OVERFLOW RAIN LEADER MAV 4 DRAWINGS,PROJECT MANUALS,AND SYSTEM BALANCING REPORTS. DCVA DOUBLE CHECK VALVE ASSEMBLY DCW MANUAL AIR VENT(MAY),AUTOMATIC AIR VENT(AAV) PIPING NOTES DEG DEGREE P PUMP,PLUMBING n 9. PURSUANT TO SECTION G408.1.3 OF THE WASHINGTON S IATE ENERGY CODE,THE .'' DF DRINKING FOUNTAIN PD PRESSURE DROP GGG�F an HVAC CONTROL SYSTEM SHALL BE TESTED TO ENSURE THAT THE CONTROL DEVICES, DI DE-IONIZED PH PHASE D W PRESSURE GAUGE 3 1. SANITARY,WASTE,AND VENT PIPING(PLASTIC NOT ALLOWED)SHALL BE NO-HUB n-a EQUIPMENT AND SYSTEMS ARE CALIBRATED,ADJUSTED,AND OPERATE IN DIA DIAMETER POC POINT OF CONNECTION CAST IRON OR DAY COPPER (/3 ACCORDANCE W . WITH THE APPROVED PLANS AND SPECIFICATIONS.SEQUENCES OF DMPR DAMPER PDX POSITIVE p GGGT VV THERMOMETER Z OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN DN DOWN PR PUMPED RETURN Q 2. HOT AND COLD WATER PIPING SHALL BE HARD DRAWN COPPER TUBING:TYPE L, ACCORDANCE WITH THE APPROVED PLANS AND SPECIFICATIONS. DS DOWNSPOUT PR PRESSUREICHLORI ATURE ASSEMBLED WITH WROT COPPER FITTINGS AND LEADAND ANTIMONY-FREE SOLDER. PVC POLYVINYL CHLORIDE Q THERMOMETER WELL 1D. THE COMMISSIONING SPECIFICATION,INCLUDING ALL FUNCTIONAL TEST E EXISTING 3. INSULATE ALL HOT AND COLD WATER PIPING WITH GLASS FIBER INSULATION WITH W PROCEDURES,SHALL BE PROVIDED AND ENFORCED BY THE CONTRACTOR. EA EXHAUST AIR WY QUANTITY ALL SERVICE JACKET.USE HEAT BONDING TAPE TO CLOSE INSULATION;STAPLES HOSE BIB CO EAT ENTERING AIR TEMPERATURE CO CO 11. PROVIDE SEISMIC RESTRAINT IN ACCORDANCE WITH IBC AND ASCE STANDARD 7. AND PRESSURE TAPE ARE PROHIBITED. EER ENERGY EFFICIENCY RATING RA RETURN AIR Q SUBMIT CALCULATIONS BY LICENSED STRUCTURAL ENGINEER IN THE STATE WHERE 4. PROVIDE ALL REQUIRED ACCESSORIES INCLUDING SHUT-OFFS AND CLEAN-OUTS. EF EXHAUST FAN RD ROOF DRAIN a7 THE PROJECT IS LOCATED.PRODUCTS MAY CONFORM TOSMACNA SEISMICEFF EFFICIENCY REF REFERENCE • Ti) RESTRAINT GUIDELINES. PROVIDE COMPONENTS WHICH PREVENT BACK-SIPHONAGEOR EG EXHAUST GRILLE READ REQUIRED SYMBOLS LEGEND-PIPING ' LLI CROSS-CONNECTIONS.PROVIDE ISOLATION DEVICES TO REDUCE SOUND EL ELEVATION RF RETURN FAN I- TRANSMISSION. EQUIP EQUIPMENT RG RETURN GRILLE SYMBOL DESCRIPTION O 12. PROVIDE A SINGLE SUBMITTAL OF ALL PLUMBING EQUIPMENT AS SPECIFIED.AS A Z MINIMUM,SUBMIT PRODUCT DATA FOR ALL EQUIPMENT AND FIXTURES LISTED IN ESP EXTERNAL STATIC PRESSURE RH RELIEF HOOD,RELATIVE HUMIDITY 5. PROVIDE STOPS FOR EACH WATER CONNECTION TO EACH FIXTURE OR ITEM OF EWT ENTERING WATER TEMPERATURE RL RAIN LEADER S STEAM TRAP ASSEMBLY O ACCOMPANYING SCHEDULES FOR APPROVAL. EQUIPMENT. EXH EXHAUST RPBFP REDUCED PRESSURE BACKFLOW PREVENTER FIT Z EWC ELECTRIC WATER COOLER RPM REVOLUTIONS PER MINUTE FR= FLOAT AND THERMOSTATIC W 13. USE EXPERIENCED INSTALLERS.DELIVER,HANDLE,AND STORE MATERIALS IN F = FLOAT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 6. DISINFECT WATER DISTRIBUTION SYSTEM.FLUSH AND TEST ALL SYSTEMS FOR EXIST EXISTING T = THERMOSTATIC W PROPER OPERATION.ADJUST SYSTEM TO PREVENT WATER HAMMER. EXP EXPANSION S SOIL B = BUCKET J EXT EXTERIOR,EXTERNAL SA SUPPLY AIR O 14. ARRANGEMENT OF SYSTEMS INDICATED ON THE DRAWINGS IS DIAGRAMMATIC,AND SD STORM DRAIN,SMOKE DAMPER IB = INVERTED BUCKET Z INDICATES THE MINIMUM REQUIREMENTS FOR PLUMBING AND MECHANICAL WORK. 7. REFER TO PIPING DIAGRAMS AND DETAILS FOR REQUIRED FITTINGS,VALVES,ETC. I = IMPULSE m ADJUST TERMINAL UNIT LOCATIONS,BASED ON FIELD MEASUREMENTS,TO AVOID FLOOR PLANS AND SECTIONS INDICATE EQUIPMENT LOCATIONS AND GENERAL PIPE F FAHRENHEIT,FIRE LINE SANS SENSIBLE 0 = ORIFICE 2 INSTALLATION ABOVE DESKS.SITE CONDITIONS SHALL DETERMINE THE ACTUAL ROUTING ONLY. FD FIRE DAMPER,FLOOR DRAIN SEER SEASONAL ENERGY EFFICIENCY RATING ARRANGEMENT OF THE WORK.TAKE FIELD MEASUREMENTS BEFORE PREPARING FDC FIRE DEPARTMENT CONNECTION SF SUPPLY FAN,SQUARE FEET p/T PRESSUREREMPERATURE TEST PORT FLA FULL LOAD AMPS SG SUPPLY GRILLE 0_ SHOP DRAWINGS,OBTAIN APPROVAL OF SHOP DRAWINGS BEFORE BEGINNING FLR FLOOR SL SOUNDLINING 3 CAP o FABRICATION.BE RESPONSIBLE FOR ACCURACY OF DIMENSIONS AND LAYOUT. FLTR FILTER SP STATIC PRESSURE Cl. OVERHEAD PIPING AND DUCTWORK SHALL BE ARRANGED TO OBTAIN MAXIMUM HEAD FM FLOW METER SPR SPRINKLER ROOM. /1 PLUG E FOB FLAT ON BOTTOM SS STAINLESS STEEL,SANITARY SEWER E FO FLAT OVAL STP STANDPIPE II UNION o 15. CLEAN AND PROTECT WORK FROM DAMAGE.RESTORE DAMAGED FINISHES.COVER FOT FLAT ON TOP ENDS OF PIPING AND DUCTWORK NOT ACTIVELY BEING WORKED ON. FPM FEET PER MINUTE T THERMOSTAT I I AYE STRAINER 0 FPS FEET PER SECOND TEMP TEMPERATURE FSD FIRE SMOKE DAMPER TG TRANSFER GRILLE pQ GATE VALVE E O FT FEET,FAN TERMINAL TOD TOP OF DUCT P.. FV FACE VELOCITY TOT TOTAL Db GLOBE VALVE N TP TRAP PRIMER,TOTAL PRESSURE GA GAGE TSP TOTAL STATIC PRESSURE Cal BALL VALVE O GAL GALLONS TU TERMINAL UNIT O N GALV GALVANIZED TYP TYPICAL * BALANCING OR PLUG VALVE 0 GPM GALLONS PER MINUTE N E UH UNIT HEATER IL411NEEDLE VALVE 'HEIGHT UON UNLESS OTHERWISE NOTED 3 HB HOSE BIBS � PRESSURE REDUCING VALVE E HC HEATING COIL V VENT,VOLT r�I�, co HD HEAD VA VALVE �'1� BALANCING/MEASURING VALVE -E HEX HEAT EXCHANGE VAV VARIABLE AIR VOLUME -p HOA HAND-OFF-AUTOMATIC VEL VELOCITY pYl RELIEF VALVE PLUMBING SHEET LIST y HP ORSEPOWER,HEAT PUMP VFD VARIABLE FREQUENCY DRIVE � 3 HPS IGH PRESSURE STEAM VTR VENT THROUGH ROOF EATING r\, CHECK VALVE Sheet O HW OTW TER W WASTE,WATER,WATT,WIDTH Sheet Title o HWC OTWATERCIRCULATING WB WET BULB C PIPE TURNING DOWNIAWAY Number PLUMBING LEGEND, NOTES&ABBREVIATIONS W HWP OT WATER PUMP WG WATER GAGE O PIPE TURNING UP HWR EATING WATER RETURN WH WATER HEATER,WALL HYDRANT P.O co WTR WATER LI: PIPE DOWN TEE • .. PIPE DOWN TEE/AWAY P.1 FLOOR PLAN-PLUMBING DEMO PIPE UP TEE1TOWAROs P.2 FLOOR PLAN-PLUMBING WASTE AND VENT a U P.3 FLOOR PLAN-PLUMBING DOMESTIC WATER P.4 PLUMBING SCHEDULE AND DETAILS UT -.YA QQS staBIPE Q ORIG �/�y A L�, PROD NAME: SHEET TITLE: SHEET: OF: DWG#: �- �` f N URN: DATE: 11.11111111.1.1. S+ .z• . 1�l • ,O DUN: DWG A: - GROUP PLOT 12/1/21 aneoaN THIS BAR IS ONE INCH CleanWa6er 111SW Fifth Ave.,Ste 2120 DURHAM WWTF PLUMBING LEGEND, DATE: 0 a�'44�,a.pd�Q. N • O CHK: CAD FILE WHEN DRAWING IS FULL Portland,Oregon 97204 H ° N oar commitm.atIsclose, WOMEN'S LOCKER ROOM NOTES &ABBREVIATIONS EL T°° SCALE. Tel 503.416.2400 PLC n: ■ N APPD: SCALE: W Fax 503.416.2087 REMODEL CWS !Expires:06/30/221 REV# DATE DRN APPD DESCRIPTION 2550 SW Hillsboro Hwy. Hillsboro,Oregon 97123-9379 WAN9696-2000r PROJ#: ENGR STAMP: FLAG NOTES 1.PLUMBING FIXTURES,NW,CW,W AND V PIPING,AND ALL ASSOCIATED ACCESSORIES TO BE REMOVED BACK TO MAINS AND CAPPED.SEE PLUMBING FLOOR PLANS FOR rig I- ADDITIONAL INFORMATION. I (E) H-1 (E)SH-1 1 I I S----- --- --- --- --- --- --- --- __ I--- — —i 1--,,y (E) D-1 v v.\ I 1 I \ 7 . , ' , (E)FD-1 T E ® j / / / / �I _ _ , I I AMIM MEE MIN A A A - , I � I vv (E)FD-1 1 I M(E)FD-1 ME ME ---- E 1//— v//// r 1 v , ' 0 1 Z El / 1 I 3 J a Z ' JI t CL CC 0 2, ; 1 d t p I E ' E 0 U /J( O y I E (E)FD-1 __ FT 7o �� co 3 (E)2„0 HW I m I COPPER i / I - u O N s, F II / I s- -_ -- / C //-- FLOOR PLAN - PLUMBING DEMO EBN S— —1-7 !'I'll SCALE:316"=1'-0" o►qDFek Q ORIG DATE'. • 'A /H� R� PROJ NAME: SHEET TITLE: SHEET. OF: DWG it: I meow CO DEN: p GROUP DSN: DWG#: PLOT, 12/1/21 Oalleou,�, THIS BAR IS ONE INCH Clean Iy ccam�__ 11,SW FiflhAve.,Ste 2120 DURHAM WWTF FLOOR PLAN - PLUMBING DATE P . 1 cHK CAD WHEN DRAWING IS FULL �7Giv1C� Portland,Oragon97204 WOMEN'S LOCKER ROOM PLC ,h' 9 J�� c� Our commitment i.elem. DEMO -,EL 70 SCALE. •Tel 503.416.2400 p1 N APED: SCALE: FaxN 6 3.4,6.2087 REMODEL IExlnres:� o�2z( REV# DATE DRN APPD DESCRIPTION 2550 SW Hillsboro Hwy. Hillsboro,Oregon 97123-9379 CWS PROJ#: ENGR STAMP: FLAG NOTES ® 17 _-----) • CONNECT NEW W,V PIPE TO EXISTING PIPE. CONNECT NEW 3"W AND 2"V PIPE TO EXISTING WASTE AND VENT PIPE. I $ < 7--- - I tg tg. 1 g g I 1 1 _ 1 7, . I , _.__,_ 1,/ \ / \ , N , I I SH-2 1 , 14 - fl - - - _ - --I- i . . 1 •.0-...,........--L, FD-p __,_ I L 1-D-1 _\,, 1 4-< x‘o / \ r,e :0 I 1 2"V-- ....i \ 1 I I I I • I _ ci"e'D I I . I 1 0 0 0 C I I L-1 -- _ ---- - ._ - - I I _ . I - _TYP 3 - - /.---- / _ ID I _ I I- II II I FD-1 1 z l 11.17--: Vil • C 1 I _ FD-1 > -- 0 • __I_ Di CM I I 1 LLI w I C III a c9 V 1 c c 1 1:° i • li 11 .... ... -:..r-1-,/ 1 CI z / 1 ,L_ 2 Z I 1 I 1 _J 0_ I I 1 °Mid 1 I CI_ CC O I 1 I LI_ ts1 I 0: (------ 1 al — J ci [ B i 1 1, 15) I cr, al E 0 FD-1 I co t i / 1 E 0 co ci > -1-7 co co -o r---r- \c , i Li3 -0 I I I ( ti FLOOR PLAN - PLUMBING WASTE AND VENT N \ -,E2- 0_ SCALE:3/8"=t-0" aj .40't Po i€44D%,,, 2 < 1 frIeS2PE 1 ORIG CO DEN SAZ A N PROJ NAME. A- SHEET TITLE. SHEET: OF. DWG: Lc> DATE: . d GROUP ,-- DSN. EGOS: DURHAM WWTF FLOOR PLAN - PLUMBING zigTE: 12/1/21 ... THIS BAR IS ONE INCH CleaxiWaterServices 111 SW Fifth Aye,Ste 2120 Portland,Oregon 97204 444,-7:14 0- CHIC_ CAD FILE A- WHEN DRAWING IS FULL WOMEN'S LOCKER ROOM WASTE AND VENT PLC 4: •2 -,z, io.. (NI Our commitment Is elem. SCALE. •rTi, 503.416.2087 REMODEL !Expires:06/30/221 FM' A P P D SCALE: CVYS REV 4 DATE ORN APED DESCRIPTION 2550 SW Hillsboro Hwy. Hillsboro,Oregon 97123-9379 SPZAN q 696.20003 PROJ A: ENGR STAMP- , • FLAG NOTES E• I>CONNECT NEW CW,HW PIPE TO EXISTING PIPE. >DEMO AND REMOVE EXISTING MIXING VALVE FOR SHOWER.PROVIDE AND INSTALL MIXING VALVE AS PER SH-1. ALL JOINTS AND CONNECTIONS TO BE SOLDERED.CONTRACTOR IS RESPONSIBLE FOR DEMOLITION WORK TO W ; ENABLE ABOVE SCOPE OF WORK TO BE COMPLETED.WHEN WORK IS COMPLETE,CONTRACTOR TO PATCH AND REPAIR WALL TO MATCH SURROUNDING SURFACES AND CURRENT EXISTING CONDITIONS. 3/4"HW • — I T i —21—f n __ : n (1 C) (l I 6 ! �/ 3/4" II a. RH 2 2 I 1 -- „ - 1 S /o -- —S t \ ; ' ,'^® I = _ ,, ;- KEE — _ i . -- I L � 1 I-D-1 1 • r•©9 1 34"HW I! s� — Q �/ i L-1 I 8 _ TYP 3 - I - 111 F' 3 _AID_ t .6_ t a, r ! 1 I d u —— i -17 i Ir FD-1 (�/-�J) I \ ` \ ' \� — — I D. FD-1 I WI W —1 WC-2 CO — i - -- 0 �J r- f�/, 1"CW 0 • • [ H I I i I! ! I I I 00 O I III O 11 M it iI I I1:is 1 1 1 `,--r - - - - —fi— - - ,j El \_.-.� - o ! I € II I X I • 1II ' 1 • • V / N 1 E FT E (� lam/} m J /'/ ' \- t'0HW I I 0M OPPER o o Cflf CVm /' C I a 20 FLOOR PLAN - PLUMBING DOMESTIC WATER �— SCALE:3/8"=1'-0" �—_ — 1 .-- - - - - - - - - /' a (._.. N Q ORIG /� A ('�`) PROJ NAME: SHEET TITLE: SHEET. OF: DWG#: �'g4�`moan 4, N. DEN: DATE: A O I DSN: DWG#: GROUP THIS BAR IS ONE INCH q�lW r sw Finn Ave.,Ste 212S DURHAM WWTF FLOOR PLAN PLUMBING PLOT 12/1/21 ^ ///��� 1r N:706 4� N DATE: a o CHIC CAD FILE WHEN DRAWING IS FULL Portland,Oregon WOMEN'S LOCKER ROOM CV Our commitment Is clear. Tel 603.4s.z400 DOMESTIC WATER PLC A: N7f` 7OJ° SCALE. • N APPD: SCALE: Fax 503.416.2067 REMODEL IExpires:06f30/221 REVS DATE DRN APED DESCRIPTION 2550 SW Hillsboro Hwy. Hillsboro,Oregon 97123-9379 SALM♦6960003 CWS PROJ#: ENGR STAMP: • PRELIMINARY PLUMBING FIXTURE SCHEDULE MARK DESCRIPTION ROUGH-IN CONNECTION IN REMARKS W V CW HW TW FD-1 FLOOR DRAIN 3 1-1/2 -- -- -- JR SMITH#2005 SERIES WITH TRAP PRIMER CONNECTION;ROUND STRAINER WITH MAXIMUM 3/8-INCH SQUARE OPENINGS. PROVIDE APPROPRIATE STRAINER HEAD TO INCORPORATE WITH FLOOR FINISH. SEE ARCHITECTURAL. SEE DETAIL 2/P501. L-1 LAVATORY 1-1/2 1-1/2 1/2 1/2 -- UNDERCOUNTER MOUNT;VITREOUS CHINA;AMERICAN STANDARD OVALYN#0496.300. 120V HARDWIRED TOUCH-FREE FAUCET: CHICAGO#EQ-C11A-51ABCP. PROVIDE WITH FACTORY TRANSFORMER.TWO LAVATORIES TO HAVE TOUCH-FREE FAUCET. ONE LAVATORY TO HAVE MANUAL FAUCET:CHICAGO FAUCETS MODEL 1100-G2E3-317AB.PROVIDE MIXING VALVE INSTALLED UNDER COUNTER BEHIND VANDAL RESISTANT ACCESS DOOR;LEONARD#170-LF. PROVIDE GRID STRAINER. COORDINATE WITH DIV.26. SH-1 SHOWER -- -- 1/2 1/2 -- PRESSURE BALANCING TYPE SHOWER MIXING VALVE WITH ADJUSTABLE STOP SCREW;ASSE 1016,SYMMONS SAFETYMIX WITH INTEGRAL SERVICE STOPS;CHROME PLATED SHOWERHEAD. SLOAN AC-11-2.5GPM-BN. SH-2 SHOWER -- -- 1/2 1/2 -- PRESSURE BALANCING TYPE SHOWER MIXING VALVE WITH ADJUSTABLE STOP SCREW;ASSE 1016,SYMMONS SAFETYMIX WITH INTEGRAL SERVICE STOPS;HAND SHOWER ASSEMBLY WITH ADJUSTABLE HEIGHT SLIDE BRACKET AND STAINLESS STEEL WALL BAR;FLEXIBLE METAL HOSE AND INLINE VACUUM BREAKER. DELTA 51308. WC-1 WATER CLOSET 4 2 1 -- -- FLUSH VALVE;WALL MOUNT;VITREOUS CHINA; AMERICAN STANDARD AFWALL MILLENNIUM#2257.101;1.28 GPF; ELONGATED BOWL. SEAT:CHURCH MODEL#295SSCT SEAT WITH SELF-SUSTAINING CHECK HINGES. 120V HARDWIRED INFRARED FLUSH VALVE WITH MECHANICAL OVERRIDE:SLOAN ROYAL OPTIMA MODEL#111-1.28 ES-S TMO. MOUNTED AT A HEIGHT TO COMPLY WITH ADA. MOUNT FLUSH VALVE HANDLE ON APPROACH SIDE OF WATER CLOSET. PROVIDE WITH FACTORY TRANSFORMER. COORDINATE WITH DIV.26. PROVIDE ADJUSTABLE HANGER FOR WATER CLOSET MOUNTING. WC-2 WATER CLOSET 4 2 1 -- -- SAME AS WC1 EXCEPT MOUNTED AT A HEIGHT TO COMPLY WITH ADA. MOUNT FLUSH VALVE HANDLE ON APPROACH SIDE OF WATER CLOSET. REMARKS: 1. COORDINATE MOUNTING HEIGHTS AND HANDING WITH ARCHITECTURAL DRAWINGS AND FIELD CONDITIONS. 2. MANUFACTURER LISTED IS BASIS OF DESIGN. PROVIDE LISTED OR EQUAL APPROVED BY OWNER,ARCHITECT,AND ENGINEER. w a w W C7 m 2 a FL. C7 0 N 0 t t/1 C1 tU a ti a0.0 mace. �'ama c* ORIG SA Z P, N PROJ NAME: SHEET TITLE. SHEET: OF: DWG#: p DRN: DATE: f GROUP DSN: DWG#: THIS BAR IS ONE INCH �Iy� �.`-- 111 SW Fifth Ave..Ste 2120 DURHAM WWTF PLUMBING SCHEDULE DA�E' 12/1/21 P 4 a,�°'�°°"�•�� CHK CAD FILE WHEN DRAWING IS FULL �eelLl�rdlGl JGIV1l CS` Portland,Oregon97204 WOMEN'S LOCKER ROOM PLC . " ° Our commitment is clear. AND DETAILS 'f� T°° SCALE. Tex 503.416.2400 `N- APPD. SCALE: Fax 503.416.2087 REMODEL IExpires:06l30/221 REV# DATE DON APPD DESCRIPTION 2550 SW Hillsboro Hwy. Hillsboro,Oregon 97123-9379 sunH ks96-Nooa PROJ#: ENGR STAMP: