Plans (3) CuratA3- 0000\7 GI-7S S'^1 5c,,.a6•j .)/#1a0
zt
NOTES:
�.5 at&t
1. REFER TO STRUCTURAL ANALYSIS . ,,.
PERFORMED BY LDC DATED < MOBILITY
• 7/02/13 ACCOMPANIED WITH ' --
THESE DRAWINGS FOR
/ 13'-8" / 13'-8" BATTERY CALCULATIONS PROPOSED
PROPOSED BATTERY AT&T MOBILITY CORP.
* PROPOSED (1) 2'-8" x 5'-2" CONFIGURATIONS. 16221 N.E.72nd WAY
SPREADER PLATE. REFER TO REDMOND,WA 98052
SHEET S-1 AND STRUCTURAL 2. STRUCTURAL ROOFTOP ANALYZED
ANALYSIS FOR DETAILS. WITH EQUIPMENT AND ANCHORAGE
SHOWN IN THE PLANS HAS BEEN in
` //�IOcltel•
PROPOSED (1) MARATHON ANALYZED IN THE REPORT vC
SEISMIC BATTERY RACK W/(20) BY LDC DATED 7/02/13. complete wireless solutions
MARATHON BATTERIES. STRUCTURAL ENGINEER TO BE
NOTIFIED BY CONSTRUCTION 4004 KRUSE WAY PLACE
PROPOSED (1) MARATHON MANAGER OF ANY DEVIATIONS 4004, #220
SEISMIC BATTERY RACK W/(20) FROM THE PLANS AND STRUCTURAL LAKE BLDG.4004,SUITE OR#220
MARATHON BATTERIES. REPORT. 97035
503-636-2500(MAIN)
//////////////////////////////////4 j ���� / ///// ////71/////////////4 REC�j�j� 503-636-2501 (FAX)
/ / 3-3•++ •+ Ll Y E SITE ID #:PR35
'I I 1� ' ' JUL 1 0 ' - ' TIGARD
6975SWSANDBURG ROAD
/ _ iw __
I _ CYOFTIG+ , II TIGARD,OR 97223
EXISTING 19" LTE FlF PROP^SED (2) DCRACK CABLE RUNS ROUTED i BUILDINGDNISIIIN FROM PROPOSED PROJECTMARATHON BATTERYw SSUEDLTE WAVE 2/3
RACK TO PROPOSED
/ COLLECTOR PLATES.
/ EXISTING UMTS w I REVIEW
CABINET PROPOSED (2) DC / m I /- SUBMITTALS
/ CABLE RUNS ROUTED /
/ �t, EXISTING TELCO DEMARC FROM PROPOSED / I w / REV. DATE DESCRIPTION BY
/ MARATHON BATTERY I I % A 10/05/12 PRELIM CDS RB
RACK TO PROPOSED w / B 11/29/12 ADD BBU RACKS RB
/ C/ EXISTING DISTRIBUTION COLLECTOR PLATES. / rn
0 02/04/13 FINAL CDS RB
/ RACK /
1 EXISTING (2) GSM / / c, ;, / mw js-N
PROPOSED (2) DC CABLE j1 07/10/13 REV STRUCTURAL RB
CABINETS. -•� I / RUNS ROUTED FROM
EXISTING GROUND N w ■ PROPOSED MARATHON N
BAR / m BATTERY RACK TO PROPOSED
> - / I I li, l_ •/ COLLECTOR PLATES.
EXISTING ALARM DEMARC / c
m/ \ PROPOSED (2) DC CABLEo Iw / RUNS ROUTED FROM lmAO/
PROPOSED MARATHON
6 / EXISTING TELCO RACK. / FA#: 10094146
\ —� REMOVED. ` / BAIItKY RACK TO PROPOSED
TO BE I W �� COLLECTOR PLATES. DRAWN BY: RB
; m I CHECKED BY: PT
8 / e --I CURRENT ISSUE DATE:
_ �� I w / PROPOSED (1) MARATHON
w / % / m I �3-3-3-3— SEISMIC BATTERY RACK W 20 07-10-13
a / / I I 1-3-3-3-3 MARATHON BATTERIES. /( )
w I II ' STAMP:
/ / NON-BEARINGNG
EXISI WALL. him
W �� PROPOSED (1) 2'-8" x 5'-2"
/ / TO BE REMOVED. / I wm ° ' SPREADER PLATE. REFER TO ` c PRO-1
N / / I i ANALYSIS FOR DETAILS.HEET S-1 AND CTURAL �S`� `G I x �u��0
Ei
o / / / mwmm 3-0
' / ; �I '�y-�— �i '' 4
7 4
OREGONo
—PROPOSED (1) MARATHON 07 f10 9'ZO
EXISTING ARGUS EXISTING (2) STRINGS PROPOSED (2) SEISMIC BATTERY RACK W/(18)MARATHON BATTERIES. D..�vv
POWER RACK. TO BE OF ABSOLYTE COLLECTOR PLATES. RENEWS: 06/30/2014
DECOMISSIONED AND BATTERIES (STACKED).
REMOVED. TO BE REMOVED.
PROPOSED ALPHA
o TECHNOLOGIES 24VDC CXPS THE INFORMATION CONTAINED IN
Y 24-4T POWER RACK. REFER THIS SET OF CONSTRUCTION
TO SHEET A-3 FOR DETAILS. DOCUMENTS IS PROPRIETARY BY
NATURE. ANY USE OR DISCLOSURE
OTHER THAN THAT WHICH RELATES
x TO AT&T MOBILITY IS STRICTLY
o N PROPOSED (2) DC CABLE RUNS N PROHIBITED.
a I ROUTED FROM PROPOSED24VDC CXPS I
24-4T POWER RACK�I > _ COLLECTOR PLATES. TO PROPOSED e._ -�'— SHEET TITLE:E
— ;-. ;-. EQUIPMENT
I I LAYOUT PLANS
0
SHEET NUMBER: REV.
24•x38 SCAIF• 1•_2. EXISTING ROOFTOP EQUIPMENT LAYOUT 1 ?;•xN17•SCALE: ;-.a' PROPOSED ROOFTOP EQUIPMENT LAYOUT 2
A-2 1
11-x17•SCALE 1� 4'�