Report �,�szoz2 oc 7 -c /322✓ &Rik /6(WY Availability: Americas Bulletin 213 October 2019 Reliable® RASCOFLEXTM Sprinkler Connections cULus Listed, FM Approved Product Description RASCOFLEXTM Sprinkler Connections are intended to connect RECEIVED a branch line to a sprinkler using a flexible stainless steel hose assembly. RASCOFLEXTM Sprinkler Connections are suitable �(� 3 Zoa� for use in suspended and hard ceiling applications such as T-Bar ceiling grids, wood, metal stud, or hat furring channel I ITV OF TIGARD hard lid ceilings. Every package contains one(1)fully assem- bled stainless steel flexible sprinkler system complete with BUILDING DIVISION hose, branch line connection, and sprinkler connection,as well as the pre-assembled bracket assembly to attach to the ceiling. RASCOFLEXTM Sprinkler Connections are designed for use in hydraulically calculated wet, preaction, or dry sprinkler sys- tems per NFPA 13, 13R, 13D, and FM Global Loss Prevention Data Sheets, Technical Data Table A RASCOFLEXTM Sprinkler Connections Maximum Working Pressure FM: 200 psi (13.8 bar) UL: 175 psi(12.1 bar) Maximum Working Temperature 300°F(149°C) Ordering Information Inlet/Branch Line 1"NPT Specify: Connections Outlet/Reducer 1/2" or 3/4" NPT Model Name Minimum Bending Radius UL: 3"(76 mm) • Model RFB FM: 7" (178 mm) Nominal Hose Length Maximum Number of Bends See Friction Loss Chart • 24"(610 mm) • 31"(790 mm) Maximum 1/2"Outlet 5.6(80 metric) • 40"(1015 mm) K-Factor 3/4" Outlet 14.0(200 metric) • 48" (1220 mm) • 60" 1525 mm) • 72"(1830 mm) Maintenance Reducer Outlet: 1/2" NPT or 3/4" NPT RASCOFLEXTM Sprinkler Connections should be inspected and the sprinkler system maintained in accordance with NFPA Reducer Type 25,as well as the requirements of any Authorities Having Standard: Jurisdiction. • 6-1/8"(155 mm)straight Optional: Patents • 4-5/16"(110 mm)straight • 5-5/16"(135 mm)straight RASCOFLEXTM Sprinkler Connections may be covered by • 11-3/4"(300 mm)straight one or more of the following US Patent Nos. 10,173,088 and • 5-5/8" (143 mm)elbow 10,328,296. • 7-3/8"(187 mm)elbow Bracket Assembly Length Listings and Approvals • 24"(610 mm)standard • FM Approved Class No. 1637(FM) 48"(1220 mm)optional UL Listed and UL Certified for Canada to ANSI/UL 2443(cULus) Accessories • See Table F www.reliablesprinkler.com Bracket Dimensions Figure 1 1 28"[711]Standard or 52"[1320] Optional n ri - CV *r - =:1:== ' --.1 ._ ^ N O N u -co N O CD "' .u. Ceiling grid shown for reference only. Verify actual ceiling grid dimensions and ceiling tile reveal prior to ordering. Co v _co Reducer Dimensions Figure 2 N ,t__ r T i M T C J_ T m co CO in ! 1 M u (h Ch C,J 4-5/16"(110 mm) 5-5/16"(135 mm) 6-1/8"(155 mm) 11-13/16"(300 mm) 5-5/8"(143 mm) 7-3/8"(187 mm) Straight Straight Straight Straight Elbow Elbow Standard I Bulletin 213 Reliable Page 2 of 8 October 2019 www.reliablesprinkler.com i Installation Dimensions Figure 3 la :.-_-== Igli - . - Y U __ t- E IN� �■IE 111 IF _ ___.1 \ === === i 1 II I;' Ceiling grid ?It shown for Ea ' reference only. 1- Verify actual I ceiling grid C° dimensions and ceiling tile reveal prior to ordering. Minimum and Maximum Face of Fitting to Bottom of Ceiling Grid for Each Reducer Table B 6-1/8" 4-5/16" 5-5/16" 11-13/16" 5-5/8" 7-3/8" (155mm) (110mm) (135mm) (300mm Straight ) (143mm) (187mm) Standard Straight Straight Straight Elbow Elbow Fig.3 Dimension A Max. Face of Fitting 3" 7mm Distance above 3" (77mm) 3" (7mm) 3"(7mm) 3"(7mm) 3"(7mm) ( ) Bottom of Ceiling Grid Fig.3 Dimension B Max. Face of Fitting 1/8" (3mm) 1-5/8"(42mm) 11/16" (17mm) 6-3/8"(148mm) 1-7/16"(36mm) 5/16"(60mm) Distance from Bottom below above above below above below of Ceiling Grid Note:Based on 1-11/16"(43mm)tall ceiling grid. Fig.3 Dimension C- Clearance Above Ceiling Required at Max.Sprinkler Recess Table C Recessed Escutcheon or Reducer Concealed/Flush Sprinkler 5-5/8"(143mm) Elbow 7-3/8"(187mm) Elbow F1 recessed escutcheon NC 5-5/8" (144mm) F2 or FV recessed escutcheon NC 5-3/8" (138mm) FP recessed escutcheon NC 6-1/4"(160mm) CCP conical concealed cover plate NC 6-1/4" (160mm) G4 series concealed sprinklers 5-5/8" (144mm) 7-3/8"(188mm) G5 series concealed sprinklers 5-1/4"(134mm) 7" (179mm) RFC series concealed sprinklers 5-1/4"(134mm) 7" (179mm) XL commercial flush sprinkler with flat escutcheon 4-7/8"(125mm) 6-5/8" (169mm) XL commercial flush sprinkler with conical escutcheon 4-3/8"(112mm) 6-1/8"(157mm) Note:NC-Reducer not compatible with sprinkler adjustment range. Based on 1-11/16"(43mm)tall ceiling grid and flush ceiling tile. Bulletin 213EMI Page 3 of 8 October 2019 www.reliablesprinkler.com Materials Figure 4 Number Item Description Material 1 Flexible Hose/Bellow AISI Type 304 Stainless Steel 2 Isolation Ring Nylon 664 ii 4 A 3 Gasket EPDM 4 4 Nut Zinc Plated Carbon Steel 8 i�.v, 5 Branch Line Nipple(1") Zinc Plated Carbon Steel 6 Reducer Zinc Plated Carbon Steel 7 Braid AISI Type 304 Stainless Steel 4 8 Welded Collar Fitting AISI Type 304 Stainless Steel - Bar Stock Zinc Plated SGCC Steel 6 - Brackets: Center and Side Zinc Plated SPCC Steel Flexible Hose Number of Bends Figure 5 One Bend Two Bends Three Bends Minimum bend radius 2x 2x Min Min bend bend radius radius OR OR Minimum bend radius I 900 i 1 L- ——— Minimum — Minimum bend radius Minimum Minimum bend radius bend radius bend radius Minimum bend radius Bulletin 213 MEE Page 4 of 8 October 2019 www.reliablesprinkler.com C ® US cULus Friction Loss Data Table D 1 Nominal Reducer Maximum Maximum Equivalent Length Length of Flexible Sprinkler Number of en g K-Factor 90° Bends at 3" of 1"(33.7mm) Hose Sch.40 Pipe in(mm) NPT Threads Type gpm/psi12 (76mm) (Ipm/bar72) Bend Radius (C=120),ft(m) 24 1/2 Straight 5.6(80) 2 10(3) (610) 3/4 Straight 14.0(200) 2 13(4) 31 1/2 Straight 5.6(80) 3 14(4.3) (790) 3/4 Straight 14.0(200) 3 16(4.9) 40 1/2 Straight 5.6(80) 4 21 (6.4) (1015) 3/4 Straight 14.0(200) 4 23(7) 48 1/2 Straight 5.6(80) 4 24(7.3) (1220) 3/4 Straight 14.0(200) 4 26(7.9) 60 1/2 Straight 5.6(80) 4 25(7.6) (1525) 3/4 Straight 14.0(200) 4 30(9.1) 72 1/2 Straight 5.6(80) 5 36(11) (1830) 3/4 Straight 14.0(200) 5 33(10.1) UL Notes: 1.Available data for use with 6.1"straight reducers. 2.Sprinkler K-Factor:5.6(80 metric)for 1/2-inch reducer and 14.0(200 metric)for 3/4-inch reducer. 3.RASCOFLEXTM Sprinkler Connections have been tested and approved by Underwriter's Laboratories, Inc.for use in wet, preaction,and dry sprinkler systems per NFPA 13, 13D, 13R and UL2443. Bulletin 213 HEM Page 5 of 8 October 2019 www.reliablesprinkler.com FM APPROVED FM Friction Loss Data Table E Nominal Maximum Maximum Reducer Sprinkler Number of Equivalent Length Length of Flexible ° of 1"(33.7mm) Hose K-Factor 90 Bends at 7 in(mm) NPT Threads Type gpm/psi12 178mm) Sch.40 Pipe (Ipm/bar'12) Bend Radius (C=120),ft(m) 1/2 Straight 5.6(80) 1 9.7(2.9) 1/2 90°Elbow 5.6(80) 0 11.5(3.5) 8.0(115) 1 9.9(3) 24 3/4 Straight 11.2(160) 1 9.8(2.9) (610) 14.0(200) 1 9.6(2.9) 8.0(115) 0 10.2(3.1) 3/4 90°Elbow 11.2(160) 0 10(3) 14.0(200) 0 9.8(2.9) 1/2 Straight 5.6(80) 2 12.4(3.8) 1/2 90°Elbow 5.6(80) 2 15.8(4.8) 8.0(115) 2 13.7(4.1) 31 3/4 Straight 11.2(160) 2 12.9(3.9) (790) 14.0(200) 2 12.2(3.7) 8.0(115) 2 14.5(4.4) 3/4 90°Elbow 11.2(160) 2 13.7(4.1) 14.0(200) 2 13(3.9) 1/2 Straight 5.6(80) 2 15.9(4.8) 1/2 90°Elbow 5.6(80) 2 21.6(6.6) 8.0(115) 2 18.5(5.6) 40 3/4 Straight 11.2(160) 2 17.4(5.3) (1015) 14.0(200) 2 16.3(4.9) 8.0(115) 2 20(6) 3/4 90°Elbow 11.2(160) 2 18.9(5.7) 14.0(200) 2 20(6) 1/2 Straight 5.6(80) 3 19.0(5.8) 1/2 90°Elbow 5.6(80) 3 25.9(7.9) 8.0(115) 3 22.7(6.9) 48 3/4 Straight 11.2(160) 3 21.5(6.5) (1220) 14.0(200) 3 20.5(6.2) 8.0(115) 3 24.8(7.5) 3/4 90°Elbow 11.2(160) 3 23.6(7.2) 14.0(200) 3 22.6(6.8) Bulletin 213 irlIFT Page 6 of 8 October 2019 www.reliablesprinkler.com f .. .. FM Friction Loss Data(cont.) Table E Nominal Maximum Maximum Reducer Sprinkler Number of Equivalent Length Length of Flexible ° of 1"(33.7mm) Hose K-Factor 90 Bends at 7" in(mm) NPT Threads type gpm/psi12 (178mm) Sch.40 Pipe (Ipm/bar12) Bend Radius (C=120),ft(m) 1/2 Straight 5.6(80) 4 23.7(7.2) 1/2 90°Elbow 5.6(80) 4 33.1 (10) 8.0(115) 4 29.1 (8.8) 60 3/4 Straight 11.2(160) 4 28(8.5) (1525) 14.0(200) 4 27(8.2) 8.0(115) 4 32.2(9.8) 3/4 90°Elbow 11.2(160) 4 31.1 (9.5) 14.0(200) 4 30(9.1) 1/2 Straight 5.6(80) 4 28.4(8.6) 1/2 90°Elbow 5,6(80) 4 40.4(12.3) 8.0(115) 4 35.5(10.8) 72 3/4 Straight 11.2(160) 4 34.3(10.4) (1830) 14.0(200) 4 33.2(10.1) 8.0(115) 4 39.5(12) 3/4 90°Elbow 11.2(160) 4 38.3(11.6) 14.0(200) 4 37.2(11.3) FM Notes: 1.RASCOFLEXTM Sprinkler Connections have been tested and approved by FM Approvals for use in wet,preaction,and dry sprinkler systems per FM data sheets 2-0,2-5,and 2-8 per FM 1637. 2.Maximum sprinkler K-Factor:5.6(80 metric)for 1/2-inch reducer and 14.0(200 metric)for 3/4-inch reducer. 3.Differences in equivalent lengths are due to varying test methods,per FM 1637 standards. 4.Above data of friction loss for use with 6.1"straight reducers. Bulletin 213MEM Page 7 of 8 October 2019 www.reliablesprinkler.com I , Accessories List Table F 5-5/8"(143mm) 7-3/8" (187mm) 4-5/16" (110mm) Elbow Reducer- Elbow Reducer Straight Reducer Short Long 1/2": 7M99003303 1/2": 7M99003302 1/2". 7M99003306 3/4": 7M99003305 3/4": 7M99003304 3/4": 7M99003325 Replacement 5-5/16" (135mm) 6-1/8"(155mm) 11-13/16"(300mm) Straight Reducer Standard Straight Straight Reducer Reducer 1/2". 7M99003307 1/2": 7M99003309 3/4". 7M99003326 : 1/2": 7M99003308 3/4": 7M99003328 3/4": 7M99003327 Hat Channel End 1 1. Hat Channel End Metal Stud End Bracket-Short Bracket- Long Bracket-Short 3"(76mm) 3-3/4" (95mm) 1-1/2" (38mm) 7M99003310 7M99003311 7M99003312 Metal Stud End T-Bar End Bracket- mm T Bar End Bracket g Bracket Long Ai ; Short 2 5/8" (68 ) Lon 4-1/8"(105mm 2 1/16"(53mm) 7M99003314 7M99003316 ) 7M99003313 Wood Beam Stud � " Replacement 3"(76 mm) End Bracket a ' Center Bracket Bend Radius 7M99003317 `., ,„. v." 7M99003321 Indicator „` ''' 7M99004179 ill Replacement Replacement 1" NPT Inlet Adapter #2 Square Drive Bit 0 1 Gasket 7M99003322 7M99004539 7M99004319 z 48"(1220mm) o ter. Bracket Assembly 7M99003301 0 01 0) 0 Bulletin 213IMIEN Page 8 of 8 October 2019 www.reliablesprinkler.com F S2O22 ' OGC,Q /322-/ (0 PKvl/Y Bulletin 148 January 2022 Reliable® F1 FR80 Series Quick Response Extended Coverage QREC Sprinklers K-factor 8.0(115) RECEIVED Features • Extended coverage quick-response sprinklers MAR 3 2022 • cULus 250psi(17.2 bar)rated 1.il l Y OF 1 IGARD • Pendent and horizontal sidewall(EC-9)deflectors IUILDING DIVISION • Low profile,compact design , • Available in a wide variety of finishes wawa, Product Description Reliable Model F1 FR80 QREC series sprinklers are quick- response extended coverage automatic fire sprinklers utilizing a sensitive 3.0 mm glass bulb thermal element. Pendent and horizontal sidewall sprinklers may be installed exposed or surface mounted using escutcheons such as the Model F1 FR80 QREC Pendent Reliable Models B, C, or HB(reference Technical Bulletin 204). When installed recessed or concealed, Model F1 FR80 QREC series sprinklers are specifically listed with and may only be installed with listed Reliable recessed escutcheons and cover plates. Refer to the technical information on the following pages for specific listings for recessed and concealed installations and refer to Figures 3 and 4 for dimensional information. `' Table A provides a summary of the approvals and availability of specific Model Fl series sprinkler configurations.Additional technical information for each sprinkler model is provided on the following pages. Note:The EC-9 horizontal sidewall deflector is also available on the cULus Listed 300 psi(20.7 bar)Model SWC concealed sidewall sprinkler. Please reference Technical Bulletin 163. Model F1 FR80 QREC Sidewall Note: Not all versions of product are shown. Sprinkler Summary Table A Sprinkler K-Factor gpm/ps11'2 Max.Working Pressure Sprinkler Model (Ipmfbar1z} Orientation Listings&Approvals psi(bar) identification Number(SIN) Pendent cULus 250(17.2)cULus R4842 F1FR80 QREC 8.0(115) FM* 175(12.0)FM Horizontal Sidewall R4862 *Note:When recessed, FM approved with F2 escutcheon only. Concealed pendent(CCP) not approved by FM. www.reliablesprinkler.com Model F1FR80 EC Pendent Sprinkler SIN R4842 Technical Specifications Sensitivity Style: Pendent Quick response Recessed Pendent Temperature Ratings Concealed Pendent 135°F(57°C) Threads:3/4"NPT or ISO 7-R3/4 155°F(68°C)I1" Nominal K-Factor:8.0(115) 41TO Max.Working Pressure: Recessed Escutcheons tkg 175 psi(12.0 bar) Model F1 250 psi(17.2 bar) Model F2 Material Specifications Cover Plates Thermal Sensor:3 mm Glass Bulb CCP(Conical)(2) Sprinkler Frame:Brass Alloy Cap:Bronze Alloy Sprinkler Wrenches Sealing Washer:Nickel with PTFE Model W2(non-recessed) Load Screw:Copper Alloy Model W4(recessed and concealed) Deflector:Brass Alloy Listings and Approvals Sprinkler Finishes cULus (See Table E) FM Notes: 1. 155°F(68°C)sprinkler is not cULus listed for 20'x 20'(6m x 6m)coverage area. 2. cULus only; 135°F(57°C)cover plate. Model F1 FR80 EC Pendent Sprinkler Components and Dimensions Figure 1 1 1/8" [30 mm] - - Threads Cap/Seal j l� Wrench 2 1/4" [59 mm] Flat 3mm \ Glass Bulb - Frame Thermal Element --- Deflector — 1" [27 mm] 148PEND Note:Please refer to Figure 3 for recessed and concealed installations. F1 FR80 EC Pendent Required Minimum Flow and Pressure Table B 16 x 16(4.9 x 4.9) 26(98.4) 10.6(0.7) 18 x 18(5.5 x 5.5) 33(125.0) 17.0(1.2) 20 x 20(6.0 x 6.0) (1) 40(151.4) 25.0(1.7) Note:cULus Listing for 20'x 20'(6.0 m x 6.0 m)coverage area is for 135°F(57°C) sprinkler only. 155°F(68°C)sprinkler is not cULus Listed for 20'x 20' (6.0 m x 6.0 m)coverage area. Bulletin 148 Re Page 2 of 8 January 2022 n www.reliablesprinkler.com Model F1FR80 EC Horizontal Sidewall Sprinkler SIN R4862 Technical Specifications Temperature Ratingsr'r Style: 135°F(57°C) Horizontal Sidewall 155°F(68°C) Recessed Horizontal Sidewall 175°F(79°C) 1 Threads:3/4"NPT or ISO 7-R3/4 Nominal K-Factor:8.0(115) Recessed Escutcheons Max.Working Pressure: Model F1(2) 175 psi(12.0 bar)(FM) Model F2 250 psi(17.2 bar)(cULus) — Material Specifications Sprinkler Wrenches Thermal Sensor:3 mm Glass Bulb Model W2(non-recessed) Sprinkler Frame:Brass Alloy Model W4(recessed) Cap:Bronze Alloy Sealing Washer:Nickel with PTFE Listings and Approvals(3) Load Screw:Copper Alloy cULus Deflector:Brass Alloy FM Sprinkler Finishes (See Table E) Sensitivity Quick response Notes: 1. Temperature ratings may vary depending on coverage area selected. See Tables C and D. 2. Not approved by FM for recessed installation; must use Model F2. 3. Approvals may vary depending on coverage area selected. See Tables C and D. Model F1FR80 EC Horizontal Sidewall(EC-9)Components and Dimensions Figure 2 1 1/2" [37 mm] —� Deflector _ 3mm It �' Glass Bulb Thermal _ _ Frame yriviT 2 7/8" [72 mm] P7141111111; Wrench gum Cap/Seal Flat �T l Threads 1 1/8" [30 mm] 148HSW Note: Please refer to Figure 3 for recessed installations. Bulletin 148 January 2022 i F I '1_ Page 3 of 8 www.reliablesprinkler.com Fl FR80 EC Horizontal Sidewall Required Minimum Flow and Pressure:cULus Table C Coverage Area Deflector Distance Flow Pressure ft x ft(m x m) Inches(mm) Temperature Rating gpm(Llmin) psi(bar) 14 x 26(4.3 x 7.9) 4-6(100-150) 135°F (57°C) 39(147.6) 23.8(1.6) 14 x 26(4.3 x 7.9) 6-12 (150-300) 135°F (57°C) 46(174.1) 33.1 (2.3) 155°F (68°C) 16 x 16(4.9 x 4.9) 4-12 (100-300) All 29(109.8) 13.1 (0.9) 16 x 16(4.9 x 4.9) 6-12(150-300) All 26(98.4) 10.6(0.7) 16 x 18(4.9 x 5.5) 4-12(100-300) All 29(109.8) 13.1 (0.9) 16 x 20(4.9 x 6.0) 4-12(100-300) All 32 (121.1) 16.0(1.1) 16 x 22(4.9 x 6.7) 4-12(100-300) All 36(136.3) 20.2(1.4) 16 x 24 (4.9 x 7.3) 4-12(100-300) All 39(147.6) 23.8(1.6) 18 x 18(5.5 x 5.5) 4-12(100-300) 135°F(57°C) 33 (124.9) 17.0 (1.2) 155°F (68°C) 18 x 22(5.5 x 6.7) 4-12(100-300) 135°F (57°C) 40.0(151.4) 25.0(1.7) 155°F(68°C) F1FR80 EC Horizontal Sidewall Required Minimum Flow and Pressure:FM Table D Coverage Area Deflector Distance Flow Pressure ft x ft(m x m) Inches(mm) Temperature Rating gpm(Llmin) psi(bar) '°°a 16x16(4.9x4.9) 4-12 (100-300) All 32(121.1) 16.0(1.1) 16 x 18(4.9 x 5.5) 4-12(100-300) All 36(136.3) 20.2(1.4) 4 ;i, 16 x 20(4.9 x 6.0) 4-12 (100-300) All 40(151.4) 25.0(1.7) 11 40 4 16 x 22(4.9 x 6.7) 4-12 (100-300) All 44(166.6) 30.2 (2.1)1 16 x 24 (4.9 x 7.3) 4-12(100-300) All 48 (181.7) 36.0(2.5) f Note: 175°F(79°C)temperature rated sprinklers not FM approved for recessed installations. 44 a k t Bulletin 148 Reliable Page 4 of 8 'e, January 2022 www.reliablesprinklercom Recessed and Concealed Installation: Pendent Sprinklers Figure 3 2-1/4" 2-1/4" r (57 mm)Dia. — (57 mm)Dia. --,', Hole in Ceiling Hole in Ceiling Face of Fitting 1-15/16" to Face of Ceiling 1-15/16" Y Face of Fitting (49 mm)Dia. Face of Ceiling 1-1/8"(29 mm)at 7/ (49 mm)Dia. 7/8"(22 mm))at Max.Recess r Max.Recess 3/8"(10 mm)at ��-- ,i %sl` 3/8" 10 mm)at l Min.Recess ` ajla *. +I Min.Recess I1 144,- - 1 4 1-3/4" (44 mm) 1" (44 mm) 1-1/4" n (25 mm) (32 mm) Minimum 2 7/8"(72 -�I Maximum Minimum i Maximum Recess — mm)Dia. --' Recess Recess -- 2-7/8"(72 mm)Dia.- -.-1 Recess Model F1 FR80 EC Pendent Sprinkler Model F1 FR80 EC Pendent Sprinkler with Model F1 Recessed Escutcheon with Model F2 Recessed Escutcheon (3/4"[19mm]adjustment) (1/2"[13mm]adjustment) 148RECPEND 2-1/2" t- (64 mm)Dia. --HI Hole in Ceiling 2-5/16" /( Face of Fitting (59 mm)Dia./ to Face of Ceiling 1-1/2"(38 mm)at Max.Recess 1"(25 mm)at Min.Recess (25 mm) Minimum (12 mm) Recess 3-5/16"(84 mm)Dia. Maximum Recess Model F1FR80 EC Pendent Sprinkler with Conical Concealed Cover Plate (1/2"[13mm]adjustment) -.r t 5 1' Pendent with Model Fl Pendent with Model CCP Recessed Escutcheon Cover Plate(Conical) (F2 similar) Bulletin 148 Page 5 of 8 January 2022 Re1ia a www.reliablesprinkler.com Recessed Installation:Horizontal Sidewall Sprinklers Figure 4 1/2"(12mm) +l 3/8"(10 mm) 1 3/8"(35 mm)MAXIMUM RECESS FACE OF FITTING 1 TO FACE OF WALL ' 1 1/2""[14mm] 2 1/4" 1 15/16" 2-7/8" (57 mm) (49 mm) p 0 j - (73 mm) DIA. DIA. UI'jll '1.1 TOP OF DEFLECTOR DIA. TO CEILING(SEE ,-✓� TABLES C&D) i l- I :. - ►1- 2 1/8"(54 mm)MINIMUM RECESS v I ' Model F1 FR80 EC Horizontal Sidewall Sprinkler with Model F1 Recessed Escutcheon ', (3/4"(19mm]adjustment) 148RECHSW i 3/8"(16 mm) +/- 1/4"(6 mm) -- 1 5/8"(42 mm)MAXIMUM RECESS r FACE OF FITTING TO FACE OF WALL ;IIk .3 '4 r 1/2""[14mm] ,r �/ 21/4" 115/16" I �,� 2-7/8" (57 mm) (49 mm) �— "1 (73 mm) DIA. DIA. i (IiIIJill i TOP OF DEFLECTOR DIA. TO CEILING(SEE TABLES C&D) s 2 1/8"(54 mm)MINIMUM RECESS t Model F1 FR80 EC Horizontal Sidewall Sprinkler with Model F2 Recessed Escutcheon (1/2"[13mm]adjustment) k t 1 r 7 Horizontal Sidewall with Model Fl Recessed Escutcheon (F2 similar) Bulletin 148 Page 6 of 8 January 2022 www.reliablesprinkler.com izzmamimummiammmm....., T Model W4(recessed,concealed) ip Model W2(non-recessed) Finishes'1'«i Table E Standard Finishes Special Application Finishes Fl and F2 CCP Cover Fl and F2 CCP Cover Sprinkler Escutcheons Plate) Sprinkler Escutcheons Plate131 Bronze Brass Chrome Electroless Nickel PTFE(4)i5i Bright Brass Bright Brass Chrome Chrome White Paint Bright Brass Black Polyester Black White Polyester(4) White Polyester Black Polyester Off White Off White Off White Satin Chrome Satin Chrome Satin Chrome Notes: 1. Other finishes and colors are available on special order.Consult your Reliable sales representative for details. 2. Paint or any other coating applied over the factory finish will void all approvals and warranties. 3. The CCP assembly consists of a bronze sprinkler mounted in a galvanized steel cup with a finished cover plate. 4. cULus Listed as corrosion resistant. 5. FM Approved as corrosion resistant. Installation Maintenance Reliable Model Fl FR80 EC series sprinklers must be installed in Reliable Model F1 FR80 EC series sprinklers should be inspected accordance with NFPA 13 and the requirements of all authorities and the sprinkler system maintained in accordance with NFPA having jurisdiction using the Reliable sprinkler installation wrench 25, as well as the requirements of any Authorities Having specified in this bulletin.Any other wrench may damage the Jurisdiction. sprinkler. The Models W2 and W4 wrenches have two sets of jaws. Use the smallest set of jaws that fit on the wrench flats Prior to installation, sprinklers should remain in the original of the sprinkler. A leak free 3/4"(R3/4)sprinkler joint can be cartons and packaging until used.This will minimize the potential obtained with a torque of 14-20 lb-ft(19-27 N.m)after applying for damage to sprinklers that could cause improper operation or a thread sealant to the male threads of the sprinkler. Do not non-operation. tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation Do not clean sprinklers with soap and water,ammonia liquid or torque may cause leakage or impairment of the sprinkler. any other cleaning fluids. Remove dust by gentle vacuuming without touching the sprinkler. Glass bulb sprinklers have orange bulb protectors or protective caps to minimize bulb damage during shipping, handling and Replace any sprinkler which has been painted(other than factory installation. Reliable sprinkler installation wrenches are designed applied).A stock of spare sprinklers should be maintained to to install sprinklers with bulb protectors in place. Remove the allow quick replacement of damaged or operated sprinklers. bulb protector at the time when the sprinkler system is placed in Failure to properly maintain sprinklers may result in inadvertent service for fire protection. Removal of the bulb protector before operation or non-operation during a fire event. this time may leave the bulb vulnerable to damage.Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. Bulletin 148 Page 7 of 8 January 2022 Reliable www.reliablesprinkler.com Guarantee For the guarantee,terms,and conditions,visit www. reliablesprinkler.com. Ordering Information Specify the following when ordering: Model • F1FR80EC Deflector/Orientation • Pendent • CCP Pendent • Horizontal Sidewall(EC-9) Temperature Rating • See sprinkler technical specifications Sprinkler Finish • See Table B Recessed Escutcheon • F1 • F2 Escutcheon Finish • See Table E Pendent Cover Plate • CCP(Conical, 135°F[57°C]only) Cover Plate Finish • See Table E Sprinkler Wrench • Model W2(non-recessed) • Model W4(recessed or concealed) ti N O r C) m Q) m z a Bulletin 148 Page 8 of 8 January 2022 www.reliablesprinkler.com