Specifications BUaOO 0o iq3 11 l o OFFICE COPY RECEIVED 'JUL 2 8 2020 CITY OF TIGARD BUILDING DIVISION THE FIELDS APARTMENTS SWIMMING POOL 7790 5W Hunziker Rd. Tigard,OR 97223 STRUCTURAL CALCULATIONS VIMK Project Number:20200009.09 MKE & Associates • 6915 SW Macadam Ave, Suite 200 Portland, OR 97219 05/15/2020 c; RUCTURq PROFFso c.c• G 41.64, to- o PQ\- E 6— 4-2021 vimmi< Prepared By: Meg Klein,EIT May 15,2020 ENGINEERING + DESIGN Structural Calculations:The Fields Apartments DC-1 Project: The Fields Apartments Pool Project Number: 20200009.04 Projed Address: 7790 SW Hunziker Rd. Document: Structural Calculations for Tigard, OR 97223 Building Permit TABLE OF CONTENTS Design Outline and Criteria DC - 1 thru DC - 2 Structural Calculations C - 1 thru C - 6 Swimming Pool Site Plan SK - 1 DESCRIPTION OF STRUCTURAL SYSTEM This project consists of a reinforced concrete below-grade swimming pool. This package includes structural calculations providing the required reinforcing steel for the radius walls of the pool for varying radii. These structural calculations are being provided to compliment drawings provided by others. This design is done with 2,500 psi concrete to avoid the need for concrete special inspection, although the concrete to be used is specified at 3,000 psi. This design is done based on 60 ksi reinforcing. Due to the specified hydrostatic relief valve, no provisions for buoyancy have been incorporated. GNlcad2020\20200009\04 The Fields Apartments SP(OR) 5.15.20\02 Calculations\The Fields Apartments Commercial SP&S DC.docx 3933 SW Kelly Avenue Portland,OR 97239 tel:503.222.4453 fox:503.248.9263 www.vlmk.com Structural Calculations:The Fields Apartments DC-2 • CODES 2019 Oregon Structural Code (Base on the 2018 International Building Code) MATERIALS Concrete Swimming Pool and Spa Walls f 'c = 2,500 psi Reinforcing Steel ASTM A615 Gr. 60 Fy = 60 ksi SOILS Per Geotechnical Engineering Report Prepared by: RhinoOne Geotechnical dated May 23, 2018 Lateral Earth Pressure (EFP) Cantilevered Wall 45 pcf G 4cad2020\20200009\04 The Fields Apartments SP(OR) 5-15.20\02 Calculations\The Fields Apartments Commercial SP&S DC.docx 3933 SW Kelly Avenue Portland,OR 97239 tel:503.222.4453 fax:503.248.9263 www.vlmk.com lai1 VLMK Project The Fields lob#: 20200009.04 By MHK Date: 5/15/2020 sheet#: C-1 ENGINEERING♦DESIGN i v3.01-Software Copyright 2015 VLMK Consulting Engineers. All Rights Reserved. Pool Wall Reinforcing Calculations - General 1' Radius Based on 2018 International Building Code and ASCE7-16 DESIGN INPUT AND GEOMETRY t(top) R = 1 ft Input 1'-0" < R < 6'-0" h1= 9 in - , 112= 6 in 12,4 _ '- h3= 24 ins ttop= 12 in P (- to= 6 in Wall/Floor Thickness T = 6 in Min Thickness - �-. p = 45 pcf Soil Pressure Wconc= 150 pcf Weight of Concrete Fy= 60 ksi Steel Strength r t(°) R ' 0 = 0.9 Load Factor '' Cc= 3 in Reinforcing Clear Cover A' 0) F'c= 2500 psi Concrete Strength \, DESIGN OUTPUT 110 \124� 19 h4= 4.5 ft 6 P. o Pmax= 201 psf Max Pool Depth 1 A . t1= 6.0 in 4'-3" p(max) ,. d(i) / t2= 6.0 in T = 6.0 in MOT,A= (1/2*h4*Pmax)(1/3*h4)*1.6= 1.07 kip-ft Point Load Distance to 'A' Resisting Moments P1= 0.113 kip d1= 0.61 ft P1*d1= 0.07 k-ft P2= 0.019 kip d2= 0.78 ft P2*d2= 0.01 k-ft P3= 0.188 kip d3= 0.36 ft P3*d3= 0.07 k-ft P4= 0.036 kip d4= 0.33 ft P4*d4= 0.01 k-ft P5= 0.036 kip d5= 0.15 ft P5*d5= 0.01 k-ft P6= 0.016 kip d6= -0.06 ft P6*d6= 0.00 k-ft 0.9*MREs,A= 0.15 k-ft MNET,A= 0.91 k-ft REINFORCING DESIGN SUMMARY d = T-Cc= 2.81 in (distance to reinforcing) As,REQ'D = 0•07 in2/ft Quantity Size Spacing Fy= 60 ksi 'A' Bars' 1 # 3 at 12 in o.c. As= 0.11 in2 'B' Bars 0 # 3 at 12 in o.c. As= 0 in2 As,TOTAL= 0.1104 in2 As,TOTAL > As,REQ'D REINFORCING IS ADEQUATE 3933 SW Kelly Avenue Portland,OR 9/239 tel:503.222.4453 far 503.248.9263 wwwvlmk.com 1 VV L M K : The Fields Job#: 20200009.04 BY: MHK Date: 5/15/2020 Sheet#: C-2 ENGINEERING+DESIGN 1-Software Copyright 2015 VLMK Consulting Engineers. All Rights Reserved. Pool Wall Reinforcing Calculations - General 2' Radius Based on 2018 International Building Code and ASCE7-16 DESIGN INPUT AND GEOMETRY 1 t(top) R = 2 ft Input 1'-0" < R < 6'-0" h1= 9 in I h2= 6 in J h3= 24 in --,-- P N11 ttop= 12 in i,,r, to= 6 in Wall/Floor Thickness T = 6 in Min Thickness t - p = 45 pcf Soil Pressure it s Wconc= 150 pcf Weight of Concrete / ..a. t Fy= 60 ksi Steel Strength r t(o) R 0 = 0.9 Load Factor i "tv' Cc= 3 in Reinforcing Clear Cover +t.0 F'c= 2500 psi Concrete Strength DESIGN OUTPUT 12.-0., .._,,,,.ir � l h4= 5.3 ft 9 a Pmax= 237 psf Max Pool Depth I A t1= 6.0 in 5'-3" p(max) d(i) t2= 6.0 in 1 T = 6.0 in MOT,A= (1/2*h4*Pmax)(1/3*h4)*1.6= 1.75 kip-ft Point Load Distance to 'A' Resisting Moments P1 = 0.113 kip d1= 1.02 ft P1*d1= 0.11 k-ft P2 = 0.019 kip d2 = 1.19 ft P2*d2 = 0.02 k-ft P3= 0.188 kip d3 = 0.77 ft P3*d3 = 0.14 k-ft P4= 0.065 kip d4= 0.68 ft P4*d4= 0.04 k-ft Ps= 0.065 kip ds= 0.37 ft Ps*ds= 0.02 k-ft P6= 0.029 kip d6= 0.00 ft P6*d6= 0.00 k-ft 0.9*MREs,A= 0.31 k-ft MNET,A= 1.44 k-ft REINFORCING DESIGN SUMMARY d = T-Cc= 2.81 in (distance to reinforcing) As,REQ'D = 0.11 in2/ft Quantity Size Spacing Fy= 60 ksi 'A' Bars 1 # 3 at 12 in o.c. AS= 0.11 in2 'B' Bars 0 # 3 at 12 in o.c. AS= 0 in2 AS,TOTAL= 0.1104 in2 As,TOTAL > AS,REQUD REINFORCING IS ADEQUATE 3933 SW Kelly Avenue Portland,OR 91239 tel:503.222.4453 fax:503.248.9263 www.vimk.com l '� VLMK ilea The Fields Jobe: 20200009.04 By: MHK Date: 5/15/2020 Sheet#: C-3 ENGINEERING t DESIGN v3.01-Software Copyright 2015 VLMK Consulting Engineers. All Rights Reserved. Pool Wall Reinforcing Calculations - General 3' Radius Based on 2018 International Building Code and ASCE7-16 DESIGN INPUT AND GEOMETRY t(top) R = 3 ft Input 1'-0" < R < 6'-0" h1= 9 in h2= 6 in Pal '" h3= 24 in N\ ttop= 12 in P . to= 6 in Wall/Floor Thickness T = 6 in Min Thickness . P0 p = 45 pcf Soil Pressure 1 E Wconc= 150 pcf Weight of Concrete ` ' -- r t(o) R I Fy= 60 ksi Steel Strength c 0 = 0.9 Load Factor ^' N Cc= 3 in Reinforcing Dear Cover illik.(,\) F'c= 2500 psi Concrete Strength ��r DESIGN OUTPUT ha= 6.0 ft 6 1 Pmax= 270 psf Max Pool Depth A / . / tl= 6.0 in 6'-3" p(mox) 1"�� d(i) /!�3✓ t2 = 6.0 in T = 6.0 in • MOT,A= (1/2*ha*Pmax)(1/3*ha)*1.6= 2.58 kip-ft Point Load Distance to 'A' Resisting Moments P1 = 0.113 kip d1= 1.31 ft Pl*dl = 0.15 k-ft P2= 0.019 kip d2= 1.48 ft P2*d2 = 0.03 k-ft P3= 0.188 kip d3= 1.06 ft P3*d3 = 0.20 k-ft Pa= 0.094 kip da= 0.93 ft Pa*da= 0.09 k-ft P5= 0.094 kip d5= 0.48 ft P5*d5= 0.04 k-ft P6= 0.031 kip d6= 0.00 ft P6*d6= 0.00 k-ft 0.9*MREs,A= 0.46 k-ft MNET,A= 2.12 k-ft REINFORCING DESIGN SUMMARY d = T-Cc= 2.81 in (distance to reinforcing) As,REQ'D - 0•18 in2/ft Quantity Size Spacing Fy= 60 ksi 'A' Bars 1 # 3 at 12 in o.c. AS= 0.11 in2 'B' Bars 1 # 3 at 12 in o.c. As= 0.1104 in2 As,TOTAL= 0.2209 in2 As,TOTAL > As,REQD REINFORCING IS ADEQUATE 3933 SW Reny Avenue Portland,OR 97239 tel:503.222.4453 fax 503.248.9263 www.vlmk.com I. VV L M K The Fields lob#: 20200009.04 By: MHK Date: 5/15/2020 sheet#: C-4 ENGINEERING I.DESIGN v3.01 -Software Copyright 2015 VLMK ConsultinjEngineers. All Rights Reserved. Pool Wall Reinforcing Calculations - General 4' Radius Based on 2018 International Building Code and ASCE7-16 DESIGN INPUT AND GEOMETRY t(top) R = 4 ft Input 1'-0" < R < 6'-0" h1= 9 in h2 = 6 in 121 h3= 24 in N ttop= 12 in P s to= 6 in Wall/Floor Thickness T = 7 in Min Thickness .-, p = 45 pcf Soil Pressure Wconc= 150 pcf Weight of Concrete �r ;r t(o) R , Fy= 60 ksi Steel Strength / 0 = 0.9 Load Factor I i ^; 00K ! CM Co= 3 in Reinforcing Clear Cover / A10) F'c= 2500 psi Concrete Strength r 114 49 DESIGN OUTPUT h4= 6.8 ft I e j Pmax= 306 psf Max Pool Depth r ,._________I 'IT A • t1= 6.4 in 7'-3" p(max) r d(i) t2= 6.9 in T = 7.0 in MOT,A= (1/2*h4*Pmax)(1/3*114)*1.6= 3.77 kip-ft Point Load Distance to 'A' Resisting Moments P1= 0.113 kip d1= 1.60 ft P1*d1= 0.18 k-ft P2= 0.019 kip d2= 1.76 ft P2*d2= 0.03 k-ft P3= 0.188 kip d3= 1.35 ft P3*d3= 0.25 k-ft P4= 0.127 kip d4= 1.18 ft P4*d4= 0.15 k-ft P5 = 0.137 kip d5= 0.60 ft Ps*ds= 0.08 k-ft P6= 0.043 kip d6= 0.00 ft P6*d6= 0.00 k-ft 0.9*MREs,A= 0.63 k-ft MNET,A= 3.14 k-ft REINFORCING DESIGN SUMMARY d = T-Cc= 3.81 in (distance to reinforcing) As,REQ'D = 0.19 in2/ft Quantity Size Spacing Fy= 60 ksi 'A' Bars 1 # 3 at 12 in o.c. As= 0.11 in2 'B' Bars 1 # 3 at 12 in o.c. As= 0.1104 in2 As,TOTAL= 0.2209 in2 As,TOTAL > As,REQ'D REINFORCING IS ADEQUATE 3933 SW Kelly Avenue Portland,OR 97239 tel:503.222.4453 fax:503.248.9263 www.vlmk.com I. VVLIVIK Ptaiete The Fields Job#: 20200009.04 By: MHK Date: 5/15/2020 Sheet#: C-5 ENGINEERING r DESIGN v3.01-Software Copyright 2015 VLMK Consulting Engineers. All Rights Reserved. Pool Wall Reinforcing Calculations - General 5' Radius Based on 2018 International Building Code and ASCE7-16 DESIGN INPUT AND GEOMETRY t(top) R = 5 ft Input 1' 0" < R < 6' 0" hi = 9 in h2= 6 in h3= 24 in v ttop= 12 in A5( �a to= 6 in Wall/Floor Thickness T = 8 in Min Thickness / IP I - p = 45 pcf Soil Pressure {' s Wconc= 150 pcf Weight of Concrete + ,t t(o) R Fy= 60 ksi Steel Strength 0 = 0.9 Load Factor Ii A Cc= 3 in Reinforcing Clear Cover 111lik0 F' = 2500 psi Concrete Strength )16.11,4 i, DESIGN OUTPUT \ h4= 7.6 8 --►�► ` ft ~ � o Pmax= 343 psf Max Pool Depth 1 • A • ti= 6.9 in 8'-3" p(max) i d(i) t2 = 7.8 in T = 8.0 in • MOT,A= (1/2*ha*Pmax)(1/3*h4)*1.6= 5.29 kip-ft Point Load Distance to 'A' Resisting Moments Pi= 0.113 kip di= 1.88 ft Pi*di = 0.21 k-ft P2= 0.019 kip d2= 2.04 ft P2*d2= 0.04 k-ft P3= 0.188 kip d3= 1.63 ft P3*d3= 0.31 k-ft Pa= 0.163 kip da= 1.43 ft Pa*da= 0.23 k-ft Ps= 0.186 kip d5= 0.72 ft P5*d5= 0.13 k-ft P6= 0.057 kip d6= 0.00 ft P6*d6= 0.00 k-ft 0.9*MREs,A= 0.83 k-ft MNET,A= 4.46 k-ft REINFORCING DESIGN SUMMARY d = T-Cc= 4.81 in (distance to reinforcing) AS,REQ'D = 0.21 in2/ft Quantity Size Spacing Fy= 60 ksi 'A' Bars 1 # 3 at 12 in o.c. AS= 0.11 in2 'B' Bars 1 # 3 at 12 in o.c. AS= 0.1104 in2 AS,TOTAL= 0.2209 in2 As,TOTAL > As,REQ'o REINFORCING IS ADEQUATE 3933 SW Kelly Avenue Portland,OR 97239 tel:503.222.4453 fax:503.248.9263 www.vlmk.com 1 1 VVLIVIK ProJett The Fields Job#: 20200009.04 BY: MHK Date: 5/15/2020 Sheet#: C-6 ENGINEERING+DESIGN v3.01-Software Copyright 2015 VLMK Consulting Engineers. All Rights Reserved. Pool Wall Reinforcing Calculations - General 6' Radius Based on 2018 International Building Code and ASCE7-16 DESIGN INPUT AND GEOMETRY t(top) R = 6 ft Input 1'-0" < R < 6'-0" h1= 9 in I h2 = 6 in WI h3 = 24 in ---7\-- 4 ttop= 12 in P ,, to= 6 in Wall/Floor Thickness T = 9 in Min Thickness - -. � p = 45 pcf Soil Pressure Wconc= 150 pcf Weight of Concrete Fy= 60 ksi Steel Strength r t(a) R T 0 = 0.9 Load Factor ^' N iopiK lik. . Cc= 3 in Reinforcing Clear Cover ���� F'c= 2500 psi Concrete Strength 4.1116k DESIGN OUTPUT e 7 h4= 8.4 ft \ll ' o Pmax= 379 psf Max Pool Depth t \ 1 A t1 = 7.3 in 9'-3" \.... ) i d(i) • t2= 8.6 in T = 9.0 in MOT,A= (1/2*h4*Pmax)(1/3*h4)*1.6= 7.16 kip-ft Point Load Distance to 'A' Resisting Moments P1 = 0.113 kip di = 2.16 ft P1*d1= 0.24 k-ft P2 = 0.019 kip d2 = 2.33 ft P2*d2 = 0.04 k-ft P3= 0.188 kip d3= 1.91 ft P3*d3= 0.36 k-ft P4= 0.201 kip d4= 1.68 ft P4*d4= 0.34 k-ft P5= 0.243 kip d5= 0.85 ft P5*d5= 0.21 k-ft P6= 0.073 kip d6= 0.00 ft P6*d6= 0.00 k-ft 0.9*MREs,A= 1.07 k-ft MNET,A= 6.10 k-ft REINFORCING DESIGN SUMMARY d = T-Cc= 5.75 in (distance to reinforcing) As,REQ'D = 0.24 in2/ft Quantity Size Spacing Fy= 60 ksi 'A' Bars 1 # 3 at 12 in o.c. AS= 0.11 in2 'B' Bars 1 # 4 at 12 in o.c. AS= 0.1963 in2 As,TOTAL= 0.3068 in2 As,TOTAL > As,REQ'D REINFORCING IS ADEQUATE 3933 SW Keay Avenue Portland,OR 91239 tel:503.222.4453 fax:503.248.9263 www.vlmk.com 4 SK-1 3.1 CI) 3.3 C)- 1 POOL GRAB RAIL'J' ~ 3.A - - -.__._, POOL SKIMMER'E' e r POOL AUTO FI1. R\i_ir O LL'0' POOL POOL IFITNESS ORAG: MECHII STORAGE EQUIP 3 0 3109 3109 3-110 ,113 JANITOR I` R POOL SIGNACE'X' POOL DEPTH 3113 RESTROOM RESTROOM MARKER'W' 3-112 3111 I POOL ADA LIFT'N' POOL RECIRCULATION 8-0' 0 - - - - IMAIN DRAIN'C' 0 L-- ' POOL HYDRO STATIC COMMUNITY I 10.-r � a RELIEF'IF , 3100 Fah. 9'-3. _, POOL LIGHT'H' gee j \ We . \ la POOL HAND RAIL'I' `-POOL RETURN'F' ® ____ 7 '- 7 III X MAINTENANC ' / \ i 3104 / \ ' I I I 0 - o — — i OFFICE 3102 JrRCEL i 0 - 3- =- . 1 -- ' - LEASING ___/ I I 3101 ® POOL EQUIPMENT LAYOUT SCALE: 1/8' = 1'-0' 0 4' 8' 16. _