li FIRE SYSTEM ACCESSORY FSac';o- Door\ 16i So O too Model 5495 SILENT Distributed Power Module tVlik KNIGHT JUL 8 MO i' Y(*TIGARD In an emergency, by Honeywell you DIVISI� you need maximum power The 5495 Distributed Power Module by Silent Knight is the most powerful and cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor®,Gentex®,AMSECO®, Wheelock and Faraday—what you need to drive power- hungry components like ADA notification appliances. The 5495's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies.And,ADA retrofits are easier and less expensive with the 5495 because it integrates into current systems without the costly investment in new components. For the most sophisticated and cost-effective notification power supply available, you need the 5495. Call Silent Knight today for more information at 1-800-328-0103. Model 5495 to non-essential high-current Distributed Power Module accessories like magnetic door holders The 5495 is a 6 amp notification power • Built-in synchronization for expander that provides its own AC appliances from System power connection, battery charging Sensor®,Gentex®,AMSECO®, circuit, and backup battery for use with Wheelock and Faraday fire and security controls such as the Silent Knight Model 5208 Fire Control • Stand alone operation /Communicator.The 5495 is the cost- • Lightweight design adds to ease of effective solution for powering installation and reduces shipping notification appliances required by the costs Americans with Disabilities Act(ADA). • Operates with most polarized, UL The 5495 has built-in ANSI cadence Listed notification devices pattern, which can upgrade older control panels that lack cadence • ANSI Cadence pattern output • capability. capability built-in Features Connection to Local Fire Control • UL Listed for 6 amps of notification The 5495 may be connected to a local fire control which utilizes Class A or Model 5495 power Class B type notification circuits Distributed Power Module • Power supply's advanced switch operating between 9 and 32 VDC.The mode design reduces damaging control panel's notification circuit is Approvals heat and manages power up to 50% connected to one of the inputs on the • UL Listed more efficiently than other systems 5495.The control panel's notification • MEA 429-92-E Vol XII • Dip switches allow for easy circuit end-of-line resistor is also • CSFM 7300-0559:123 reconfiguration connected across two terminals on the • • 24 VDC filtered output voltage 5495, which provides supervision NFPA 72 • Four power-limited notification between the 5495 and the fire control • OSHPD (CA)OSP-0065-10 outputs; 2 Class A or 4 Class B, or 1 panel. Polarized audible and/or visual (see accessories) Class A and 2 Class B notification devices are then connected • Additional continuous auxiliary to the 5495 signal circuits using the output 4.7kc end-of-line resistors provided. Since the 5495 draws very little power • 3 amps per output circuit from the control, it is possible to • 2 inputs; 2 Class B or 2 Class A connect one 5495 to each notification • Ground fault detector/indicator circuit on the control panel and still • Independent trouble relay provide full supervision of the • AC loss delay option shuts off power notification circuits all the way back to the control panel. FIRE SYSTEM ACCESSORY Model 5495 Distributed Power Module Model 5495 Block Diagram Signal Circuit Output Signal 1 Signal 1 Input Distributed Signal 2 Signal Circuit Output Signal 2 Power Input Module 5495 Signal 3 (Optional) Signal 4 120 VAC Aux. Power Trouble Output Local Fire Control (Alternative to notification circuit trouble.) Supervision Current: Input The 5495 supervises a variety of Standby 75 mA voltage range: 9 -32 VDC functions including: Alarm 205 mA Battery charging • Low AC power Auxiliary capacity: 35.0 AH • Low battery condition power circuit: 1 Ambient temp.: 32° to 120° F • Earth ground fault Notification (0° to 49° C) • Auxiliary output power limit circuits: 4 Mechanical condition Output Dimensions: 12.25" W x 16" H x • EOL supervision trouble or configuration: 2 Class A(Style Z) 3" D (30.88 cm W power limited condition at an 4 Class B (Style Y) x 40.64 cm H x output (1 Class A& 7.62 D cm) When a trouble condition occurs, 2 Class B) Indicator Lights the 5495 creates a trouble Amps per AC power on : Green condition on the host control signal output circuit: 3.0 (6.0 amps circuits to which it is connected. the p p total) Battery trouble: Yellow 5495 still maintains the ability to be Notification Ground fault: Yellow activated by the host control. In circuit output: 20.4 to 27.3 VDC addition, the 5495 provides a Form @ 3.0 amps each, Aux trouble: Yellow C trouble relay output as an 4.7 kS2 EOL Output troubles (1-4): Yellow alternative to using the notification resistor required Ordering Information circuit trouble. on each Class B 5495 Distributed Power Module circuit Electrical Specification Accessories: AC input: 120 VAC at 2 ampsNo. of inputs 2 p Input SK-SCK Seismic Compliance Kit Output: 24 VDC at 6 amps configuration: 2 Class B or 2 Class A SILENTNi it document is not purposes. MADE IN AMERICA KNIGHT This keep our product informationintended up-to-datetobeused andfor accurate.installation We cannot coverWetry allto specific applications or anticipate all requirements.All specifications are FORM#350395 Rev F subject to change without notice.For more information,contact Silent Knight ©2013 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northford,CT 06472-7161 Phone: (800)328-0103, Fax: (203)484-7118.For Technical Support,please call 800-446-6444. www.silentknight.com Altronix® AL3000LX Series Power Supply/Chargers0,1 • La • ' Description loge Altronix AL3000LX series power supply/chargers convert a 115VAC 60Hz input /rt into a single fused, four(4), eight (8) or sixteen (16)fuse or PTC protected outputs. ,�;' Outputs are selectable for 12VDC or 24VDC with a total of 2.5A max. rwPit AL3000LPD8 — Key Features - Available with 1, 4, 8 or 16 outputs. - Short circuit and overload protection. - Fused or PTC ptotected outputs. - AC input and DC output options. - Supervision: - UL Listed in the U.S. and Canada. -AC Fail. - CSFM and MEA Approved. - Battery Fail and Battery Presence. - Lifetime Warranty/Made in the U.S.A. - Built-in charger for sealed lead acid or gel type batteries. - All units are available in grey or red enclosure*. - Instantaneous transfer to stand-by batteries. *AL30oULXJ's enclosure is red.For grey enclosure order model AL3000LXJG AL3000LX series Power Supply Configuration Reference Chart Total Output Input Input Power Supply Power Number Fused PTC Altronix Rating Rating: Fuse Output Distribution of Outputs Auto-Resettable Accommodates Model Number (A) 115VAC,60Hz Rating Fuse Rating Modiule Outputs Ratings Outputs Ratings Batteries AL3000LX Two(2)7AH AL3000LXX N/A 1 3.5A — Two(2)12AH AL3000LXJ(G) Two(2)18AH AL3000LPD4 PD4UL 4 3.5A — Two(2)7AH AL3000LPD4CB 2.5A 3.5A 5A/250V 15A/32V PD4ULCB 4 — 2.5A Two(2)7AH AL3000LPD8 PD8UL 8 3.5A — Two(2)7AH AL3000LPD8CB PD8ULCB 8 — 2,5A Two(2)7AH AL3000LXPD16 Two(2)PD8UL 16 3.5A — Two(2)12AH AL3000LXPD16CB Two(2)PD8ULCB 16 — 2.5A Two(2)12AH Rev.AL3000LX-04242017 AL3000LX Series Altro n i x® Power Supply/Chargers . - Specifications Input Agency Listings Voltage 115VAC,60Hz, 3.5A max. Access Control UL294 Fusing 5A/250V. Burglar Alarm UL603 Hospital Signaling UL1069 Outputs Fire Alarm UL1481 Voltage 12VDC or 24VDC selectable. California State Fire Marshall Approved Current 2.5A power-limited continuous max. Protection Fused 3.5A/PTC 2.5A, Physical and Environmental Other Overvoltage protection, Dimensions(H x W x D) Filtered and regulated. AL3000LX,AL3000LPD4(CB),AL3000LPD8(CB): PTC protected outputs are auto-resettable. 13.5"x 13"x 3.25" (342.9mm x 330.2mm x 82.6mm). AL3000LXX,AL3000LXPD16(CB): Back-up Battery (not included) 15.5"x 12"x 4.5" (393.7mm x 304.8mm x 114,3mm). Capacity 7AH/12VDC(1 or 2 within enclosure). AL3000LXJ: 12AH/12VDC(requires larger"X"enclosure). 18"x 14.5"x 4.625"(457.2mm x 368.3mm x 117.5mm). 18AH/12VDC(requires larger"J"enclosure). Product/Shipping Weight (approx.) 40 AH/65 AH(requires separate enclosure). Type Sealed lead acid or gel type. Model Product Weight Shipping Weight AL3000LX 8.3 lbs. (3.76 kg) 9.2 lbs(4.17 kg) Charging current 0.7A. AL3000LXX 10.1 lbs. (4.58 kg) 11.4 lbs. (5.17 kg) Fuse Rating 15A(4)32VDC. AL3000LXJ(G) 11.5 lbs. (5.22 kg) 13.7 lbs(6.21 kg) Failover Upon AC loss, instantaneous. AL3000LPD4(CB) 8.45 lbs. (3.83 kg) 9.35 lbs(4.24 kg) AL3000LPD8(CB) 8.7 lbs. (3.95 kg) 9.6 lbs(4.35 kg) Supervision AL3000LXPD16(CB) 10.1 lbs. (4.58 kg) 11.4 lbs(5.17 kg) AC Failure Form "C" contacts. Temperature • Battery Form "C"contacts. Operating 0°C to 49°C(32°F to 120°F). Storage -20°C to 70°C(-4°F to 158°F). Indicators (LED) Relative Humidity 85%+/-5%. Input 115VAC is present. BTU/Hr. (approx.): DC Output Powered. 12VDC: 15 BTU/Hr. Battery Discharged or not connected. 24VDC: 31 BTU/Hr. • Aftronix Corporation 1 140 58th St I Brooklyn,NY 11220 USA phone:+1 718.567.8181 I fax:+1 718.567.9056 I email:info@altronix.comlwww.altronix.com *Th, SYSTEM SENSOR ,, 7r. Photoelectric .. ��'��1," Smoke Detectors System Sensor i3"series smoke detectors represent $ significant advancement in conventional detection. The i3 family is founded on three principles:installation TM ease,intelligence,and instant inspection. Features Installation ease.The i3 line redefines installation ease with its •Plug-in detector line,mounting base included plug-in design.This allows an installer to pre-wire bases(included with heads).The large wire entry port and in-line terminals provide •Large wire entry port ample room for neatly routing the wiring inside the base.The base •In-line terminals with SEMS screws accommodates a variety of back box mounting methods as well as •Mounts to octagonal and single gang back boxes,4-square back direct mounting with drywall anchors.To complete the installation,i3 boxes,or direct to ceiling heads plug into the base with a simple Stop-Drop'N Lock' action. •Stop-Drop'N Lock attachment to base Intelligence.i3 detectors offer a number of intelligent features •Removable detector cover and chamber to simplify testing and maintenance.Drift compensation and •Built in remote maintenance signaling smoothing algorithms are standard with the i3 line to minimize nuisance alarms.2-wire i3 detectors can generate a remote LED- •Drift compensation and smoothing algorithms indicated maintenance signal when connected to the 2W-MOD2 •Simplified sensitivity measurement loop test/maintenance module or a panel equipped with the i3 •Wide-angle,dual color LED indication protocol.The SENS-RDR,a wireless device,displays the sensitivityof i3 detectors in terms of percent-per-foot obscuration. •Loop testing via EZ Walk feature •Built-in test switch Instant inspection.The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition:normal standby,out-of-sensitivity,alarm,or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the i3 protocol,the EZ Walk loop test feature is available on 2-wire i3 detectors.This feature verifies the initiating loop wiring by providing LED status indication at each detector. Agency Listings ® ® ( - MEA MSFM LISTED APPROVED I approved approved S911 3011446 7271-1653-152 290-01-L _._.. . C r ,11 (j)Smoke Detector Specifications ? Architectural/Engineering Specifications ti - Smoke detector shall be a System Sensor i3 Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The 1` detector shall be a photoelectric type(Model 2W-B,4W-8)or a combination photoelectric/thermal(Model 2WT-B,4WT-B)with thermal sensor rated at 135°F i (57.2°C).The detector shall include a mounting base for mounting to 31/-inch and 4-inch octagonal,single-gang,and 4-inch square back boxes with a plaster ring,or direct mount to the ceiling using drywall anchors.Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the ir base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box.The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual- rl color LED indication that blinks to indicate power up,normal standby,out of sensitivity,alarm,and freeze trouble(Model 2WT-B,4WT-B)conditions.When used Alf1 in conjunction with the 2W-MOD2 module,2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Electrical Specifications Operating Voltage Nominal: 12/24 V non-polarized Minimum: 8.5 V Maximum:35 V Maximum Ripple Voltage 30%peak to peak of applied voltage Standby Current 2-wire:50 pA maximum average;4-wire:50 pA maximum average Maximum Alarm Current 2-wire:130 mA limited by control panel;4-wire:20 mA @12 V,23 mA @ 24 V Peak Standby Current 2-wire:100 pA;4-wire:n/a Alarm Contact Ratings 2-wire:n/a;4-wire:0.5 A @ 30V AC/DC Physical Specifications Dimensions(including base) 5.3 inches(127 mm)diameter;2.0 inches(51 mm)height Weight 6.3 oz(178 g) Operating Temperature Range 2W-B and 4W-B:32°F to 120°F(0°C to 49°C);2WT-B and 4WT-B:32°F to 100°F(0°C to 37.8°C) Operating Humidity Range 0 to 95%RH non-condensing Thermal Sensor 135°F(57.2°C)fixed Freeze Trouble 2WT-B and 4WT-B only:41°F(5°C) Sensitivity 2.5%/ft nominal Input Terminals 14 to 22 AWG Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring i Direct mount to ceiling LED Modes Power-Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal(standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information Model Thermal Wiring Alarm Current gm II 2WT-B Yes 2-wire 130 mA max.limited by control panel 4W-B No 4-wire 20 mA @ 12 V,23 mA @ 24 V 4WT-B Yes 4-wire 20mA@12V,23mA@24V Accessories 2W-MOD2 2-wire loop test/maintenance module RT Removal/replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket,6.6 inch(16.76 cm)diameter i *- \\ STEM ©2009 System Sensor. ``� 3825 Ohio Avenue•St.Charles,IL 60174 Productspecifianonssubjecttochangewthoutna¢eVisityrstemsensorcomfor ... SENSOR Phone:800-SENSOR2•Fax:630-377-6495 current product information,including the latest vers'on of this data sheet. A05-0318-007.6/09•#2169 V, SYSTEM � SENSOR" D4120 Duct Smoke Detector "`or • The lnnovairFlexTM Series are the only duct smoke detectors flexible enough to fit configurations from square to rectangular and everything in between. �irfte innove Features The InnovairFlex D4120 4-wire photoelectric duct smoke • 4-Wire Photoelectric,integrated low-flow technology detector features a pivoting housing that fits both square and rectangular footprints and mounts to round or rectangular ductwork. • Air velocity rating from 100 ft/min to 4,000 ft/min This unit senses smoke in the most challenging conditions,operating (0.5 m/s to 20.32 m/sec) in airflow speeds of 100 to 4,000 feet per minute,temperatures • Versatile mounting options:square or rectangular configuration of—4°F to 158°F,and a humidity range of 0 to 95 percent(non- • Plug-in sensor offers superb false alarm immunity and the latest condensing).A plug-in sensor head offers improved false alarm immunity and simple installation,testing,and maintenance.An sensor technology improved cover design isolates the sensor head from the low-flow • Broad ranges for operating temperature(-4°F to 158°F)and feature for simple maintenance. humidity(0%to 95%non-condensing) • Patented sampling tube installs from front or back of the detector The InnovairFlex housing provides ample wiring space,a 3/4-inch with no tools required conduit knockout,and built-in short circuit protection to prevent damage to sensitive components during installation.High contrast • Increased wiring space with a newly added 3A-inch conduit terminal designations make wiring easy.With its 2:1 sensor-to-power knockout capability,the power board of the D4120 may be used to monitor a • One easy-access Test/Reset button and improved LED status second sensor,D4S,simultaneously(i.e.,supply and return side). • Patented interconnect feature for multi-fan shutdown As many as 50 InnovairFlex detectors can be interconnected.When one unit senses smoke,all interconnected detectors will switch • New high contrast terminal designations their relays;only the detector sensing smoke will go into alarm,thus • Built-in short circuit protection from operator wiring errors pinpointing the fire source. • Field selectable settings for configuring the detector An easy-access Test/Reset button makes it possible to test the unit • Two DPDT Form-C relay contacts with the cover on.Three DIP switches can be used to configure field selectable settings:cover tamper delay,number of sensors to • 24 VAC/DC or 120 VAC be controlled,and shut down on trouble option.Each power board • Backward compatibility with existing Innovair products, including has two LEDs that can be used to indicate the status of connected remote accessories sensors,and a quick reference imprinted on the cover explains the LED status indications(Standby,Maintenance,Trouble,and Alarm). The InnovairFlex duct smoke detector can be customized to meet local codes and specifications without additional wiring.The new InnovairFlex product line is compatible with all previous Innovair Agency Listings models, including remote test accessories. At v WARNING:Duct smoke detectors are NOT a substitute for open ° 0 0 area smoke detectors;NOT a substitute for early warning detection; LISTED APPROVED NOT a replacement for a building's regular fire detection system. S911 3033744 3242-1653.0207 Refer to NFPA 72 and 90A for additional information. lnnovairFlexTM Duct Smoke Detector Specifications Architectural/Engineering Specifications The air duct smoke detector shall be a System Sensor InnovairFlex"D4120 Photoelectric Duct Smoke Detector.The detector housing shall be UL listed per UL 268A specifically for use in air handling systems.The flexible housing of the duct smoke detector fits multiple footprints from square to rectangular.The detector shall operate at air velocities of 100 feet per minute to 4000 feet per minute(0.5 to 20.32 meters/second). The unit shall be capable of controlling up to 50 air handling systems when interconnected with other detectors.The detector shall be capable of providing a trouble signal in the event that the front cover is removed.It shall be capable of local testing via magnetic switch,test button on the cover,or remote testing using the RTS2-AOS Multi-Signaling Accessory or the RTS151 KEY Remote Test Station.Terminal connections shall be of the strip and clamp method suitable for 12-18 AWG wiring. Physical Specifications Size:(Rectangular Dimensions) 14.38 in(37 cm)Length;5 in(12.74 cm)Width;2.5 in(6.36 cm)Depth (Square Dimensions) 7.75 in(19.7 cm)Length;9 in(22.9 cm)Width;2.5 in(6.35 cm)Depth Weight: 2.5 lbs(1.14 kg) Operating Temperature Range: D4120&D4S:-4°to 158°F(-20°to 70°C); D4P120:-40°to 158°F(-40°to 70°C) Storage Temperature Range: D4120&D4S:-22°to 158°F(-30°to 70°C); D4P120:-40°to 158°F(-40°to 70°C) Operating Humidity Range: 0%to 95%relative humidity non-condensing Air Duct Velocit : 100 to 4000 ft/min 0.5 to 20.32 m sec Electrical Ratings Power supply voltage: 20-29 VDC 24 VAC 50-60 Hz 120 VAC 50-60 Hz Input capacitance: 270 pF max. 270 pF max. N/A Reset voltage: 3.0 VDC min. 2.0 VAC min. 10 VAC min. Reset time:(with RTS151) .03 to 0.3 sec. .03 to 0.3 sec. .03 to 0.3 sec. Reset time:(by power down) 0.6 sec.max. 0.6 sec.max. 0.6 sec.max. Power up time: 35 sec.max. 35 sec.max. 35 sec.max. Alarm response time: 15 sec. 15 sec. 15 sec. Sensitivity Test: See detector label See detector label See detector label Current Requirements:(Using No Accessories) Max.standby current: 21 mA @ 24VDC 65 mA RMS @ 24VAC 60Hz 20 mA RMS @ 120VAC 60Hz Max.alarm current: 65 mA @ 24VDC 135 mA RMS @ 24VAC 60Hz 35 mA RMS @ 120VAC 60Hz Contact Ratings Alarm initiation contacts: 2.0A @ 30 VDC(resistive) (SPST) Alarm auxiliary contacts: 10A @ 30 VDC(resistive); 10A @ 250 VAC(resistive);'/2 HP @ 240 VAC;1/4 HP @ 120 VAC (DPDT) Note:Alarm auxiliary contacts shall not be connected to initiating circuits of control panels.Use the alarm initiation contact for this purpose. Supervisory contacts:(SPDT) 2.0A @ 30 VDC(resistive);2.OA @ 125 VAC(resistive) Accessory Current Loads at 24 VDC Device Standby Trouble Alarm APA151 12.5 mA n/a 30 mA Max. MHR/MHW 0 mA n/a 29 mA Max. RA100Z 0 mA n/a 12 mA Max. RTS151/RTS151KEY 0 mA/12 mA n/a 12 mA Max. RTS2/RTS2-AOS 3.0mA max 16 mA Max. with strobe:55 mA max;without strobe 30 mA max Note:Any combination of accessories may be used such that the given accessory loads are: 110 mA or less at the Aux output,and 50 mA or less at the Alarm output Installing the InnovairFlex Sampling Tube The InnovairFlex sampling tube may be installed from the front or back of the detector.The tube locks securely into place and can be removed b releasin•the front or rear lockin•tab front lockin•tab shown below ri•ht. 000 tt r sa x } r t€ /f ,jrilftr.,(7iNt c` Wiring for 4-wire Duct Smoke Detector and Accessories POWER INPUTS(NOTE 1) POWER INPUTS(NOTE 1) 4VAC/1 IVACi r4V i rVAC 9 10 9 10 OR OR AUXILIARY CONTACTS AUXILIARY CONTACTS FOR FAN SHUTDOWN,ETC.(NOTE 2) FOR FAN SHUTDOWN,ETC.(NOTE 2) AUX A AUX B AUX A AUX B N N N N N N N•. ojo 16 6 17 8 18 7 6 6 17 8 18 7 EOL RESISTOR SPECIFIED BY SUPERVISORY CONTACTS SUPERVISORY CONTACTS PANEL MANUFACTURER (NOTE 3) (NOTE 3) SUP . SUP C SUP N o. SUP I � UUFM LISTED 14 3 14 3 4-WIRE CONTROL PANEL ALARM a ALARM N.O. ALARM s ALARM N.O. ALARM INITIATION INITIATION INITIATION CONTACTS CONTACTS LOOP \ (NOTE 4) (NOTE 4) \\\ 4 ALARM C 4 ALARM C 1 I —— FIRST DETECTOR IN THE LOOP LAST DETECTOR IN THE LOOP NOTE 1:24V Power Inputs accept a non-polarized 24VDC or 24VAC NOTE 3:Supervisory contacts shown in standby position.Open 50-60Hz. 120VAC Power Inputs accept only 120VAC contacts indicate a trouble condition to the panel.See 50-60Hz.Connect power source to appropriate terminals specifications for contact ratings. of each detector.See specifications for additional power NOTE 4:Alarm Initiation contacts shown in standby position.Closed supply information. contacts indicate an alarm condition to the panel.See NOTE 2:Auxiliary contacts shown in standby position.Contacts specifications for contact ratings. switch during alarm as indicated by arrows.Auxiliary contacts are not to be used for connection to the control panel.See specifications for contact ratings. *Please refer to the corresponding installation manual for accessory wiring diagrams. Important Notes on 2:1 Sensor-to-Power Capability •2:1 sensor-to-power capability is not available for all InnovairFlex models. The feature is only available on the D4120 4-wire conventional models. •2:1 sensor-to-power capability can be enabled using one D4120 and one D4S,or two D4S and one D4P120. Important Interconnect Notes •When using the interconnect feature,all interconnected units must be powered using the same independent supply. •Polarity must be maintained throughout the interconnect wiring.Connect the INT+terminal on unit 1 to the INT+terminal on unit 2 and so on.Similarly,connect the INT/AUX—terminal on unit 1 to the INT/AUX-terminal on unit 2 and so on. •Up to 50 D4120 units,50 D4P120 units,or 50 units of combination may be interconnected. •Up to 10 DH100ACDC units may be interconnected.Please note that each of the 9 DH100ACDC units interconnected may be replaced by three D4P120 units.Therefore,when using the interconnect feature a single DH100ACDC can drive either 9 DH100ACDCs or 27 D4120 units. NOTE:Alarm can be reset only at the initiating device and not at the devices interconnected. Accessories System Sensor provides system flexibility with a variety of accessories,including two remote test stations and several different means of visible and audible system annunciation. As with our duct smoke detectors,all duct smoke detector accessories are UL listed. � r ktlF i',. r r RTS151 UL S4011 RTS151KEY UL S2522 APA151 UL S4011 RTS2-AOS UL S2522 Fi't=i4 i it; 1111 x�:•at f tttuza.r aza;ec� F j } RA100Z UL S2522 MHW UL S4011 MHR UL S4011 AOS Ordering Information Part No. Description D4120 4-wire photoelectric low-flow duct smoke detector Accessories D4S 4-wire photoelectric sensor component only ETX Metal exhaust tube duct width 1ft(0.3m) D4P120 4-wire photoelectric power board component M02-04-00 Test magnet only,24 VAC/DC,120 VAC 2D51 4-wire conventional photoelectric sensor head MHR Mini Horn,Red DST1 Metal sampling tube duct width up to 1ft(0.3m) MHW Mini Horn,White DST1.5 Metal sampling tube duct widths 1 ft to 2 ft P48-21-00 End cap for metal sampling tubes (0.3 to 0.6 m) DST3 Metal sampling tube duct widths 2 ft to 4 ft RA100Z Remote annunciator alarm LED (0.6 to 1.2 m) DST5 Metal sampling tube duct widths 4 ft to 8 ft RTS151 Remote test station (1.2to2.4m) DST10 Metal sampling tube duct widths 8 ft to 12 ft RTS151 KEY Remote test station with key lock (2.4 to 3.7 m) APA151 Remote annunciator with piezo alarm RTS2-AOS Multi-signaling accessory with add on strobe * 1 SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 @2013 System Sensor. l �r Phone:800-SENSOR2•Fax 630-377-6495 Product specifications subject to change without notice.Vialtsystemsensor.com SEA SOR for current product information,including the latest version of this data sheet. ,vJ www.systemsensor.com HVDS00502•10/13 . AIR PRODUCTS AND CONTROLS PAM SERIES L j,:: MULTI-VOLTAGE RELAY MODULES You in Control The PAM Series Relays are encapsulated multi-voltage devices with"flying" leads that offer versatile,reliable perfor- ' mance in a convenient package. Several of the versions contain a red LED which indicates when the relay coil is energized. The PAM Series Relays are packaged with a self-tapping screw and a piece of double sided tape for easy , installation almost anywhere. The relays are also packaged with wire-nuts to aid installation. PAM Relays are ideal for applications where remote relays are required for control or status feedback. They are suitable for use with HVAC,Temperature Control,Fire Alarm,Security,Energy Management,Lighting Control Systems and Building Automation Systems. PRODUCT DESCRIPTION PAM-I The PAM-1 Relay provides 10.0 A form"C"contacts. The relay may be energized by one of three input voltages: 24VDC,24VAC,or 120VAC. The input voltages are 1t ®-» i polarity-sensitive and diode-protected. PAM-I Relays contain a red LED which :: indicates when the relay coil is energized. PAM-2 , The PAM-2 Relay provides 7.0 A form"C"contacts. The relay may be energized by one of two input voltages: I2VDC or 24VDC. The input voltages are 1}_ polarity-sensitive and diode-protected. PAM-2 Relays contain a red LED which ,. indicates when the relay coil is energized. PAM-4 The PAM-4 Relay provides 10.0 A form"C"contacts. The relay may be energized c _ across a wide voltage range from I 2VDC to 40VDC,making it ideal for I 2VDC and 24VDC EOL circuits. The 20mA operating current is constant across the , ,.' m operating range. The input voltages are polarity-sensitive and diode-protected. I= o.- ,- PAM-SD ;.. 'I The PAM-SD Relay provides 7.0 A form "C" contacts. The relay may be Is fe :w_ "'° --..,, _ energized by an input voltage between 20VDC to 32VDC,making it ideal s ...., ,:,, for 24VDC NAC circuits. The input voltages are polarity-sensitive and diode- .' protected. The PAM-SD provides an additional set of wires for redundant ' "N. input voltage (circuit supervision pass through). SEWING . C 0us 0; CSFM LISTED MEA ACCEPTED , LISTED y Air Products and Controls is Distributed By: a Brand of Apollo America —A— :_ 25 Corporate Drive ''_ Auburn Hills, MI 48326 HALMA (248) 332-3900 Phone GROUP (888) 332-2241 Toll free COMPANY (248) 332-8807 Fax www.ap-c.com ' a zF WIRING RELAY ENERGIZED LED ®©©WHT ��\ "� BLU C RELAY ENERGIZED LED s ""©® � YEL 10.0 A Eit BL�� CONTACTS @ uREDORG +24VDC 20mA � YE NCNTA@ »N..`\ ORG NO CONTACTS 120VAC @ 50mA +12VDC 20mA "`�„ 24VAC @ 50mA 24VDC @ 20mA PAM-2 PAM-1 12VDC (+) RED w BLU C 20VDC _ WHT. �s BLU TO YEL @ 15mA (-) • 'S ` C 40VDC \,` NC 10.0 A TO \\ \ YEL NC 7,0 A @ BLK .� ORG CONTACTS 32VDC (+) , .\ ORG CONTACTS 20mA (-) \-_______Ot NO @ 25mA (+) RED.''\ \\\. NO PAM-4 PAM-SD PRODUCT SPECIFICATIONS , MODEL NUMBER: PAM-1 PAM-2 PAM-4 PAM-SD COIL VOLTAGE: 24VAC/24VDC/120VAC 12VDC/24VDC 12 t0 40VDC 20 to 32VDC ,- POLARIZED: Yes Yes Yes Yes ENERGIZED LED INDICATOR' Yes Yes No No z. CURRENT REQUIREMENT: @12VDC 20mA 20mA @24VDC 20mA 20mA 20mA 15mA '• _©32VDC 20mA 25mA @24VAC 50mA @12OVAC 50mA ;' CONTACT CONFIGURATION: (1)SPDT dry form"C" (1)SPDT dry form"C" (1)SPDT dry form"C" (1)SPDT dry form"C" CONTACT RATINGS: •, (contact rating/power factor) @5VDC 250pA/.35 PF 250pA/.35 PF 250pA 250pA!.35 PF @24VDC 7A/.35 PF 7A/.35 PF 7A 7A/.35 PF @12OVAC 10A 7A/.35 PF 10A 7A/.35 PF 4'- RELAY PULL-IN TIME: @12VDC < 1s <5s @24VDC < 1s < 1s <3s < 1s ©32VDC < 1.5s < 1s ` @24VAC < 1s .s @120VAC < 1s WIRE LEADS: 6"flying"leads 6"flying"leads 5"flying"leads 7"flying"leads 12"/18 AWG 12"/18 AWG 12"/18 AWG 12"/18 AWG Wire-nuts provided Wire-nuts provided Wire-nuts provided Wire-nuts provided `, AMBIENT TEMPERATURE: 32°F to 120°F 32°F to 120°F 32°F to 120°F 32°F to 120°F (@ 100%RH,condensing) (0°C to 49°C) (0°C to 49°C) j (0°C to 49°C) (0°C to 49°C) .- CONSTRUCTION: 100%potted(sealed)with"flying"leads MOUNTING: Pre-drilled mounting screw hole and self tapping screw provided.Double sided tape provided. fr DIMENSIONS: H I 1.50"(38mm) 1.50"(38mm) 1.50"(38mm) j 1.50"(38mm) W ( 1.20"(31mm) 1.20"(31mm) 1.20"(31mm) 1.20"(31mm) D 0.77"(20mm) 0.77"(20mm) 0.77"(20mm) 0.77"(20mm) ji LISTINGS AND APPROVALS: UL*: UOXX/7.S3403 UOXX/7.S3403 UOXX/7.S3403 UOXX/7.S3403 MEA: 73-92-E Vol.21 73-92-E Vol.21 73-92-E Vol.21 73-92-E Vol.21 CSFM: 7300-1004:101 7300-1004:101 7300-1004:101 ( 7300-1004:101 ,, `UOXX=Control Unit Accessories,System;/7=also Certified for Canada ,i NOTICE:The information contained in this document is intended only as a summary and is subject to change without notice. The products described have specific instructiownaarstallation documentation,which covers vanous technical,approval,code,limitation and liability information.Copies of this documentation along with any general product warning and limitation documents,which also contain important information,are provided with the product and are also available from Apollo Amnerica Inc. I. The information contained in all of these documents should be considered before specifying or using the products. Any example applications shown are subject to the Ir most current enforced local/national codes,standards,approvals,certifications,and/or the authority having jurisdiction. All of these resources,as well as the specific manufacturer of any shown or mentioned related equipment,should be consulted poor to any implementation. For further information or assistance concerning the products, ''?} contact Apollo America Inc. Apollo America Inc.reserves the right to change any and all documentation without notice. ©Apollo America Inc.2016 DS-RL-1 F161104 SYSTEM SENSOR® ills, Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut Tr installation times and maximize profits with lower y ,1 current draw and modern aesthetics. Features • Updated Modern Aesthetics The System Sensor L-Series offers the most versatile and • Small profile devices for Horns and Horn Strobes easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With white and red • Plug-in design with minimal intrusion into the back box plastic housings,standard and compact devices,and plain,FIRE, • Tamper-resistant construction and FUEGO-printed devices,System Sensor L-Series can • • Automatic selection of 12-or 24-volt operation at 15 and 30 meet virtually any application requirement. candela The L-Series line of wall-mount horns,strobes,and horn strobes • Field-selectable candela settings on wall units: include a variety of features that increase their application versatility 15,30,75,95, 110, 135,and 185 while simplifying installation.All devices feature plug-in designs • Horn rated at 88+dBA at 16 volts with minimal intrusion into the back box,making installations fast • Rotary switch for horn tone and two volume selections and foolproof while virtually eliminating costly and time-consuming ground faults. • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before To further simplify installation and protect devices from construction device installation damage,the L-Series utilizes a universal mounting plate for all • Electrically Compatible with legacy SpectrAlert and SpectAlert models with an onboard shorting spring,so installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range • Listed for wall mounting only of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING LISTED APPROVED 1 '"I L-Series Specifications Architect/Engineer Specifications General L-Series standard horns,strobes,and horn strobes shall mount to a standard 2 x 4 x 1 7/8-inch back box,4 x 4 x 1 Y-inch back box,4-inch octagon back box,or double-gang back box.L-Series compact products shall mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit° Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs } shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95,110, 135,and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR12 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 1.91`D(143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions(including lens) 5.26"L x 3.46"W x 1.91"D(133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.25"D(143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25"L x 3.45"W x 1.25"D(133mm L x 88mm W x 32mm D) 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. { • UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) . 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR t Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 i Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1K Temporal High 93 156 53 73 119 140 164 190 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1K Temporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9* Coded High 85 90 90 10* 3.1 KHz Coded High 84 89 89 Settings 9 and 10 are not available on the 2-wire horn strobes. ss •. tfa4tWla..0.0441.1. F444411.01•{J)UINI/ kU4.tit444 s 4,1", 44u4uu+ a ,"rv:.1....14.Eiti.iifSNNM14i,01.4W tl 41tf4.4,r ... ,:,....a .,r..:..r.. ,.u..,.,.. ....s..s., .urn.:±e .:.•.•s .. ••,....•, •.ffr,u'4w furuf•s4'.. • L-Series Dimensions E-, 1.91 ----- 3.46 3.46 �, 1.25 I l 1.25 1 =� • "01r1". ) / ouo•°00° o 00000000000 000000 5.27 dli 5.27 a o"o°o"o°o .'. 001 . ...'--------ii•=='-_ _,..!. IL. III Compact Strobe/Horn Strobe Compact Horn 4.70 1.91 4.70 1.25 f,l� 1.25 - .11 1--- -(-' --- mir'...\"%fir--fj 5.67 •"`"`. III 67 vtifvtin r %,,,A' 1 (",.....„A„.1) `vial..,I II '�'�'�'•'�' Ill ll K`=o J) Strobe/Horn Strobe Horn I I L-Series Ordering Information • Model Description Model Description Wall Horn Strobes Horns P2RL 2-Wire,Horn Strobe,Red HRL Horn,Red P2WL 2-Wire,Horn Strobe,White HWL Horn,White P2GRL 2-Wire,Compact Horn Strobe,Red HGRL Compact Horn,Red • P2GWL 2-Wire,Compact Horn Strobe,White HGWL Compact Horn,White P2RL-P 2-Wire,Horn Strobe,Red,Plain Accessories P2WL-P 2-Wire,Horn Strobe,White,Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire,Horn Strobe,Red,FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire,Horn Strobe,White,FUEGO SBBRL Wall Surface Mount Back Box,Red Wall Strobes SBBWL Wall Surface Mount Back Box,White SRL Strobe,Red SBBGRL Compact Wall Surface Mount Back Box,Red SWL Strobe,White SBBGWL Compact Wall Surface Mount Back Box,White SGRL Compact Strobe,Red SGWL Compact Strobe,White SRL-P Strobe,Red,Plain SWL-P Strobe,White,Plain SRL-SP Strobe,Red,FUEGO SWL-CLR-ALERT Strobe,White,ALERT Notes: All-P models have a plain housing(no"FIRE"marking on cover) All-SP models have"FUEGO"marking on cover C All-ALERT models have"ALERT"marking on cover *T .SYSTEM 3825 Ohio Avenue•St.Charles,IL 60174 ©2017 System Sensor. • SENSOR Phone:800-SENSOR2•Fax:630-377-6495 or curiespecificationsrrt rrrrat to change withoutlatestiVe,visit systemsensoccorn for current product Information,including the latest Vernon of this data sheet. www.systemsensor.com AVDS86502.02/17 arrraa^s"raarr+d+u+ws+rwra'+xn tnliKlYNt I rrkrruxu ka[/rule ! ukk[nkrYdadkr.rn.kiaikNk3ttL#t11iW33/FAnFF„-...... - SYSTEM r. _' SENSOR`[' Indoor Selectable- Ia �r µ ril Output Strobes and .. 6 Horn Strobes for `'`4,,p a Ceiling Applications ,* System Sensor L-Series audible visible notification products are rich with features guaranteed to cut r installation times and maximize profits with lower ar,., I current draw and modern aesthetics. Features The System Sensor L-Series offers the most versatile and • Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings,wall and ceiling mounting options,System Sensor • Automatic selection of 12-or 24-volt operation L-Series can meet virtually any application requirement. at 15 and 30 candela • Field-selectable candela settings on ceiling units: The entire L-Series product line of ceiling-mount strobes and horn • 15,30,75,95, 115, 150,and 177 strobes include a variety of features that increase their application versatility while simplifying installation.All devices feature a plug-in • Horn rated at 88+dBA at 16 volts design with minimal intrusion into the back box,making installations • Rotary switch for horn tone and two volume selections fast and foolproof while virtually eliminating costly and time- consuming ground faults. • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,the L-Series utilizes a universal r before device installation mounting plate so installers can mount them to a wide array of back i? • Electrically Compatible with legacy SpectrAlert and SpectrAlert boxes.With an onboard shorting spring,installers can test wiring I Advance devices continuity before the device is installed. • Compatible with MDL3 sync module ri Installers can also easily adapt devices to a suit a wide range of • Listed for ceiling mounting only application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING ® APPROVED LISTED 35512 FM approve°except 7125-1653.0504 34011 for ALERT models 7135-1653.0503 3057383 1 , L-Series Specifications Architect/Engineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 115,150,and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9"diameter x 3.4"high(175 mm diameter x 86 mm high) (SBBCRL,SBBCWL) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. 6 AVOS66600 • J� UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts Candela DC DC FWR 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1K Temporal High 111 164 69 94 147 163 184 229 257 3.1K Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 " 3.1K Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 Volts Volts Switch Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS86800 r 6 L-Series Dimensions � - 2.47 1.37 - - 0 6.92 2.50 06.83 o iij g o o g i 0 0(--- i. 0 .�. goo 1,)8\__ , __-- { r J Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box pp 0 co . I iii,e,7,;.,---. 21-TIiiill ® 1gm � F co yes � . Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information Model Description Model Description Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire,Horn Strobe,Red SCRL Strobe,Red PC2WL 2-Wire,Horn Strobe,White SCWL Strobe,White SCWL-CLR-ALERT Strobe,White,ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box,Red SBBCWL Ceiling Surface Mount Back Box,White *� 3825 Ohio Avenue•SYSTEM ©2017 System Sensor Product specifications subje St.Charles,IL 60174 subject to change without notice.Visit systemsensoccom �� SENSOR' Phone:800-SENSOR2•Fax:630-377-6495 for current product information,Including the latest version of this data sheet. AVDS86801•03r17