Loading...
PFI2022-00239 CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT a COMMUNITY DEVELOPMENT Permitm PF12022-00239 Date Issued: 06/08/2022 13125 SW Hall Blvd..Tigard OR 97223 503.718.2421 Parcel: SEG618 Jurisdiction: Tigard Site address: Subdivision: Lot: Project: Ziply Fiber 5513035 Project Description: Access 2 MH's 1 HH. Bore 1013' in between them. Place duct and fiber. Overlash fiber to existing aerial path 513', riser down pole. Bore 50'to HH on customer property and place duct and fiber. From HH, place pull fiber to customer building. SEG 618 Class of Work: FEES Type 1 - Utilities(gas,electric, data) Description Date Amount Total Owner: REQUIRED INSPECTIONS Call 503-639-4175 for the IVR inspection request line or visit the City of PHONE: Tigard website at www.tigard-or.00v to schedule inspections online. Contractor: PHONE: Applicant: ANNA KARASEVA 6074 N DISCOVERY WAY STE 125 BOISE,ID 83713 PHONE:2085764031 Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact information of responsible parties before beginning work. Permittee/Applicant Signature: See application Issued By: Special Conditions(See Attached) Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY Conditions for PF12022-00239 Type; Condition Name: Status: Severity: PFI_Utilities 01 -WORK SITE REQUIREMENTS Applied Notice Applicant must comply with all applicable provisions of federal and state law,the Tigard Municipal Code,and the terms of any agreement with the City of Tigard regarding work to be done pursuant to this permit, PFI_Utilities 02-WORK SITE AREA Applied Notice The work area and approach roads shall be maintained in a clean condition,free from obstructions and hazards. The spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up and suspension of work to accomplish clean-up. PFI_Utilities 03-WORK SITE EROSION CONTROL Applied Notice Prior to starting work,effective and approved erosion control devices must be installed and maintained meeting the Clean Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to accomplish effective erosion control. PFI_Utilities 04-WORK SITE REPAIRS Applied Notice Disturbed landscaped areas shall be restored or replaced. Existing signs,pavement markings, mailboxes,etc. shall be reinstalled or replaced,with like kind of material. Obtain City approval of restoration work. PFI_Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices [MUTCD]for Streets and Highways", U.S. Dept.of Transportation, FHWA,current edition,American Traffic Safety Services Association[ATSSA),and Oregon Temporary Traffic Control Handbook[OTTCHj. PFI_Utilities 06-TRAFFIC CONTROL PLAN Applied Notice Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work area. Traffic control devices,flag persons,etc., shall be in place prior to initiation of construction work and shall be effectively maintained. PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice Public roadway shall not be closed to traffic,at any time,without obtaining written approval from the City Engineer. The applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and area wide Emergency Services: 503-629-0111 (Tigard Police Dept.,Tualatin Fire&Rescue)and to 503-962-8140(Tri-Met)and 503-431-2345(Tigard School District)and other service providers impacted by such closure. PFI_Utilities 08-TRAFFIC CONTROL ADVANCE WARNING Applied Notice Advance warning of traffic disruption shall be provided to the public by placement of an approved advance notification sign at each end of the construction area 72 hours(min.)before initiation of construction work. PFI_Utilities 09-TRAFFIC CONTROL PROPERTY ACCESS Applied Notice Access to existing properties shall be maintained at all times, including normal delivery service and mail service. Obtain City approval of any access closures. PFI_Utilities 10-TRAFFIC CONTROL WORK HOURS Applied Notice Work is permitted in daylight between the hours of 7:00 a.m.to 7:00 p.m. Mon-Fri unless otherwise authorized by the City. PFI_Utilities 11 -TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the City Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m.to 9:00 a.m. unless authorized by the City Engineer. PFI_Utilities 12-TRAFFIC CONTROL MODIFICATION Applied Notice The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to assure public safety. PFI_Utilities 13-DRAINAGE CONTROL Applied Notice Drainage shall be controlled within the work site and shall not adversely affect adjacent private property, public property and the receiving system. The City may at any time order corrective action and suspension of work to accomplish effective drainage control. PFI_Utilities 14-UTILITY NOTIFICATION Applied Notice Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR 952-001-0100 through OAR 952-001-0080. Copies of said rules maybe obtained from the Center by calling 503-246-1987. If you have any question about the rules, contact the Center. NOTE:Damage to utilities shall be corrected at the permit holder's expense. PFI—Utilities 15- UTILITY LOCATION CONFLICT Applied Notice Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at the applicant's expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work with affected utility agencies. PFI_Utilities 16-TEMPORARY PATCH Applied Notice A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is liable for hazards or damage resulting from the prosecution of the work. PFI_Utilities 17-REPAIR OF EXISTING FACILITIES Applied Notice Work under this permit shall include repair of existing facilities(roads, ditches,etc.)as may be necessary, as determined by the Inspector,to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit. Corrective work shall be done at the applicant's expense. PFl_Utilities 19-PRECONSTRUCTION MEETING Applied Notice Before initiating any construction activity,the applicant shall coordinate with the City's inspector,<Insert Name>at<Insert Phone#>,to establish a preconstruction meeting. PFI_Utilities 20-NOTICE TO COMMENCE WORK Applied Notice The applicant shall notify the City's Inspector twenty-four(24)hours prior to commencing work,prior to any staged inspection, and after completing work covered by the permit. Contact Ken Fisher at 503 816 6146 or kenny@tigard-or.gov PFI_Utilities 21 -PERMIT/PLAN ON SITE Applied Notice A copy of the permit including a Certificate of Insurance,and all attachments,and a copy of the approved construction plan and all amendments shall be readily available at the work area. All work shall conform to the permit terms,conditions and provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work performance. PFI_Utililies 22-DAILY INSPECTION REPORTS Applied Notice Applicant shall submit daily inspection reports,on a weekly basis,to the City's Inspector. PFI_Utilities 23-MONUMENT PROTECTION Applied Notice Existing monuments, property corners,and survey markers shall be protected. Replacement shall be at the permit holder's expense. PFI_Utilities 24-VALIDATION OF MATERIAL/CONSTRUCTION Applied Notice The City's Inspector may,at his discretion, require tests and or reports from the applicant to validate claims of material or construction adequacy/compliance. Such tests/reports shall be provided at the applicant's expense. PFI_Utilities 25-EMERGENCY CONTACTS Applied Notice Provide to the City inspector, in writing,the names and 24 hour emergency telephone number of two(2)persons who have authority to resolve problems,take corrective action and, in general,will be responsible in case of any emergency. The applicant shall notify the City Inspector, in writing, of any/all assignment changes. PFI_Utilities 26- RIGHT OF ENTRY/EASEMENTS Applied Notice Applicant to obtain proper right-of-entry and/or easements prior to starting work. Proof of right-of-entry or properly executed easements,shall be provided to the City. The City shall in no way be construed to be liable for the applicant's failure to obtain or provide for proof of right-of-entry or easements. PFI_Utilities 27- PRIVATE PROPERTY AGREEMENTS Applied Notice Provide the City a copy of an executed agreement[s]from the owner for each private property disturbed by construction activity. PFI Utilities 28-AS-BUILT DRAWING Applied Notice 1,2,3,4,5 28-AS-BUILT DRAWING One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and,also,any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance). 1,2,3,4,5 28-AS-BUILT DRAWING One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and,also,any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance). One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and,also, any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance). PFI_Utilities 31 -OTHER Applied Notice Other City of Tigard PFI#: PF12022-00239 ENGINEERING DEPARTMENT Public Facilities Improvement (PFI) Permit PROJECT INFORMATION 5513035 TYPE OF WORE Project name: E5 TYPE 1—Franchise Utility Work ACCESS 2 MH'S 1 HH BORE 1,013'IN BETWEEN THEM performed by NWN,PGE, or utility Brief description of project: Bey PLACE DUCT&FIBER.OV ERLASH FIBER TO EXISTING AERIAL PATH 513',RISER DOWN POLE ❑ TYPE 2—ROW Sidewalk/Driveway/Sewer BORE 50"10 111-ION CUSTOMER PROPERTY PLACE DUCT&FIBER.FROM HH PLACE PULL Work performed for the purpose of: 'WIAC01 • Sidewalk installation or repair • Driveway approach installation and repair SITE INFORMATION • Sanitary sewer lateral installation and Location (address if available): 11485 SW 95TH AVE TIGARD OR 97223 main line tap ❑ TYPE 3—Full Scale Development Work performed with land use approval which includes any of the following: • Subdivisions or Partitions APPLICANT INFORMATION • Street widening Name: ZIPLY FIBER-ANNA KARASEVA • Mainline installation for sanitary sewer, storm sewer, Tigard water, and Tigard Mailing address: 6074 N DISCOVERY WAY STE 125 water service area City/State: BOISE ID zip: 83713 ❑ TYPE 4—Small Cell Technology Phone: 208-576-4031 ❑ TYPE 5—Tigard'Triangle Email: permitting@mountainitd.com Phone: NOTE: Type 1 and 2 applications may be Contact name: emailed to rowpermitsa.tigard-or.gov. Phone: Einail: CONTRACTOR INFORMATION ❑ Same as applicant Name: NORTHSKY - GUY CASTONGUAY CCB Number: 208747 Mailing address: 11818 SE MILL PLAIN BLVD STE 410 City/State: VANCOUVER WA Zip: 98684 Phone: 503-209-6856Ei Triad: gcastonguay@northskycomm.com ENGINEER INFORMATION Name: RUSS WELLS Mailing address: 4155 SW CEDAR I IB,1,S BLVD City/State: BEAVERTON OR Zip: 97005 503-643-1001 Phone: Email: rs5eu.weu3@ziply.c2m ADDITIONAL INFORMATION Estimated value of work is required(if over$5,000):$ (within the public right-of-way) Is work related to a LAND USE DECISION? ❑Yes ❑No Case number: G/z s*-u t3 wt!5 2& Ls A+Lrk e.r.a c.- wat tL- ~kJ g t4WI <tAJ 'T :ev A—,. � 3:� P'`. 4Z..g-,d.c-r U-f" Kt sr%E2 A-r &a& Vw L.-'r tz Cityof Tigard • 13125 Six'Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 • Puge 1 of 4 APPLICANTS NOTE: Person specified as "Applicant"shall be designated"Permittee"and shall provide financial assurance for work,if required by the city pursuant to TMC 15.04.140. * With the exception of a utility operating pursuant to a valid franchise or license with the City of Tigard,when the owner and the applicant are different people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the owner. The owner must sign this application in the space provided or submit a written authorization with this application. Franchised or Licensed Utilities are not required to obtain the owners signature on the application. 1,the applicant,certify that: • To the best of my knowledge, all the information provided within this application package is complete and accurate. • The above request does not violate any recorded deed restrictions that may be attached to or imposed upon the subject property. • If the application is granted,I will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. AnnaXaraseva ANNA KARASEVA 6/1/22 Applicant's or authorized agent's signature Print name Date Property owner's signature (if required) Print name Date rAFF USE ONLY Case No: PF''12//022--00239 rert Received by: GV Date: 6/1/22Approved by: F� . r,S l�Lt, U —'� .;v Notified by. Date: �? �i Cityof Tigard 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.Ogard-or.gov • 503-718-2421 • Page 2 of 4 L DEVELOPMENT ENGINEERING FEES Public Facility Improvement(PFI)Permit: INITIAL PFI PERMIT FEE Part is Required submittal fee is 10%of the Net PFI Pertnit Fee.See below for calculations. Minimum of$300. NET PFI PERMIT FEE Part 2: All non-water system improvements engineer's estimate X 7%(less the initial PFI Permit Fee). WATER LINE CONSTRUCTION FEE Part 3: All public water system improvements engineer's estimate X 12%. FOR ONLY • ' STAFF USE ONLY TYPE 4: SMALL WIRELESS FACILITY TYPE 1-3: DETAILED SUBMITTAL CHECKLIST REQUIREMENTS Does applicant have a right-of-way license? ❑Yes ❑No TYPE 1 AND TYPE 2-Must include a sketch showing: Under the wireless facilities standards,is the proposal ❑ Dimensions considered?(check all that apply): ❑ Small Cell ❑Macro ❑ Street Name How many install sites are proposed as part of this permit ❑ Site Address application? TYPE 3-Must provide 4 sets of plans (sized 24 x 36 or 22 x 34) and an electronic version of all submittal The proposed equipment is located on which of the following: items. The plans must that include: ❑Public Right-of-Way ❑Private Property ❑ Cover—Site,Vicinity,Abbreviation,Legend If equipment is to be located on private property,describe the ❑ General Notes (City,Water,Sewer,etc) type&use: ❑ Street(Plan,Profile) ❑ Water,Storm and Sanitary(Plan Profile) ❑ Water Quality Facilities ❑ Grading ❑ Landscaping/Tree Plan ❑ Composite Utility Plan(Electrical,Phone,Gas, Storm, Sanitary,Water,Signage,Street Lights,etc.) ❑ Details ❑ Traffic Sight Distance ❑ Signing and Striping ❑ Street Light Plan and Photometric ❑ Engineers seal/signature ❑ Sheet label(project land use name,revision and plan log block,dates and sheet numbers.) ❑ Engineer's Construction Estimate Additional Submittals (per land use conditions,if applicable) ❑ Traffic Report ❑ Storm water Drainage Calculations ❑ Geotechnical Report ❑ Preliminary Access Report(Sight Distance) ❑ Proposed Plat ❑ Pathway Design ❑ Water Provider Approval City of Tigard 13125 SW Hall Blvd. Tigard,Oregon 97223 • www.figard-or.gov • 503-718-2421 • Page 3 of 4 Edge of Pavement Ditch Streetlight I A•—•—•—•—•—•—•— —r--- Drat I f. 'Oe" ' T–Fi-opos cf'Selwer'Cine" � � I 1 Nr inI Existing House YIs I Existing i Driveway dI I ON I 1 I I rl a J o r Existing Shop j L Powerpole I la 95' T-roperty Lige— Fire Nyd rant(FH) I I I I I Scale: '1"=30' � I I TYPE I AND TYPE 2: MINIUM SKETCH REQUIREMENTS (Put N/A if not I I I � I I ' I I � I ; applicable) North arrow Property lines&dimensions Existing utilities locations (sewer,storm,water) Street&street names All existing structures Proposed work Existing curb or edge of pavement Utility&street light poles Existing S/W or D/W apron Slope of property Trees City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 • Page 4 of 4 Page 106 2011 Edition Diversion into a Continuous Left Turn Lane Diagram 430 Diagram 430 shows work in the travel lane(s) next to a continuous two-way left turn lane with one direction of traffic diverted into the continuous two-way left turn lane. 1. Use truck-mounted flashing warning lights on work and protection vehicles. See Section 4.3 — Lights and Lighted Signs for exceptions. 2. For added visibility, a truck-mounted arrow board or PCMS in caution mode may be used. 3. When two or more travel lanes are reduced to a single lane before the diversion, each lane shall be closed separately. Layout traffic control according to ODOT Standard Drawing TM 852 for 5-lane sections. 4. A shifting taper(L/2) may be added in the diverted traffic direction across the continuous two-way left turn lane (as shown). This option is recommended when the speed is 45 mph or greater. Sign Spacing and Buffer Lengths(feet) Posted Spedne8etweenSi6ro "Buffer" Spend A B c Spam 20 50 25 100 100 100 75 30 100 35 350 3S0 350 125 40 150 45 180 50 500 500 500 210 S250 60 285 65 700 700 700 325 70 365 Chapter 5 September 2016 2011 Edition Page 107 Diversion into a Continuous Left Turn Lane Diagram 430 RonD WDRK AHEAD B Il t CENTER LONE CLOSER AHEAD A if U2 � • I Buffer Protection Vehicle w/TMA(both Optional) /See Chapter 4 Buffer • • U2 • it • L/2 A 1yt B WoR AHEAD September 2016 Chapter 5 Page 84 2011 Edition Stationary Lane Closure with Flagging Diagram 320 Diagram 320 covers total closure of one lane of a two-lane, two-way roadway. See the detail inset for the layout if using a single flagger to control both directions of traffic on low volume roads (less than 400 ADT)with good sight distance as discussed below. 1. Use truck-mounted flashing warning lights on work and protection vehicles. See Section 4.3— Lights and Lighted Signs for exceptions. 2. For added visibility, a truck-mounted arrow board or PCMS in caution mode may be used. 3. Flaggers at each approach are required if any of the following conditions exist: a. Night Operations. b. Work space is over 200 feet in length. c. Sight distance is less than 750 feet from each approach through the lane closure. d. Traffic volumes are greater than 400 ADT. 4. The length between the Flagger Ahead signs shall not exceed one mile. Use Diagram 340— Lane Closure with Pilot Car if exceeding one mile. 5. Cones should be used to outline the work space when curves or other roadway alignments prevent clear direction for the motorists to pass the work space safely. 6. Canes along the work space are recommended when posted speeds are 45 mph or greater, when working under heavy traffic or when travel lanes are narrower than 11 feet. 7. Extended queue signing (see Diagram 5-4) should be used when traffic queues extend beyond the initial advance warning sign. 8. When flagging near an intersection, the"Flagger Ahead" (CW23-2) sign should be visible to traffic entering from any side road. Additional advance warning and Flagger Ahead symbol signs may be placed on the side road(s). 9. Sign set-up and flagger placement shown may be used for intermittent full road closures of 20 minutes or less. 10. The"ONE LANE ROAD AHEAD" (W20-4) sign is optional and should be considered on high volume or high speed roads, or when extended queues are expected. Chapter 5 September 2016 2011 Edition Page 85 Stationary Lane Closure with Flagging Diagram 320 occ 3Q p W � � a O n Wo� a 0 o¢a \ x M W ; X11 o m a L 3 Q • m c • 0.2-,f >o� BU B 4 t I E E h a�� � T I •� 3 p i I • <o fit , I '. a E O Oa I 0)>v I O< LLL m� I Y I Way 05ii I Sign Spacing and Buffer Len hsfeet Posted Spacing Between Signs "Buffer" \ Z ^ C Speed A B I c SpaceO g u37 m 20 so _¢¢ O 25 100 100 100 75 I O 30 100 35 4a 350 iso iso ssu o Y 45 160 0 0M s0 soo 500 Soo 210 ¢ 3¢ ss 250 fia 285 65 700 700 700 325 70 365 September 2016 Chapter 5 ° ^ ue CUSTOMER: ORDER#' ISSUED: DUE: o ADDRESS: 0 SERVICE TYPE: O "'"' ASSIGNMENT: m. m..""""` ,•,a.. TEST.- dB Q kHz O 4. " - ,,,,Ab.•� SPECIAL NOTES: s 7 µl ) fi i p� UNITS /ACCT CODES 0 000 °oo O ® 1 O REVISIONS ) � I ® ziply fiber 5513035 ASHBROOK VILLAS 0 PROJECT 5513035 c,o.aREA TIGARD NUMBER: EXCH.CODE, OR PUG MARD DRAWN DATE: ENGR RUSSELL WELLS CNTY: 5519095 ASH6ROOIIVILLAS 51192022 PHONE W12-7330 FILE: SCALE. 1.466.3 TAXDISTRICT:— I DWG 1 7 TNNSHP. -- RNG — SEC: — 5135145513035 GREEN FIELD—ASHBROOK VILLAS-34 SFU—TIGARD—OR Ziply Fiber Contacts THIS PROJECT PROVIDES FOR FIBER SERVICE TO 23 NEW LOTS IN ASHBROOK VILLAS. THERE ARE A TOTAL ADDRESSES OF Engineer: 34 SFU. THIS PROJECT PROVIDES FOR ALL PLACING AND SPLICING LABOR,FIBER AND MATERIALS. THIS DESIGN WILL PROVIDE RUSS WELLS FOR ALL 23 NEW LOTS AND 11 ADDITIONAL HOME. 503-312-7330 Inspector: JESS LIDDELL 360-9ies: 7 Facilities: UNITS /A CCT CODES ROBYN RUSSEL 503-260-9525 SPLICING/PLACING REED HJORT 971-343-2450 RYAN ROBERTS 503-643-3713 GENERAL CONSTRUCTION NOTES: MANY FACWTIES AND CABLES ARE OMITTED FOR CLEARITY. ALWAYS UTILIZE ALL PERSONAL PPE. PROVIDE APPROVED TRAFFIC CONTROL PLAN. ALWAYS GET LOCATES BEFORE ANY AND ALL DIGGING, ATTENTION HIGH VOLTAGE OVER HEAD POWER ALONG THIS ENTIRE WORK HOURS: AREA. ANY CHANGES OR ADDITIONS NEED TO BE PRE—APPROVED BY THE LOCAL PLACING —68 ENGINEER. FOLLOW ALL LOCAL AND FEDERAL SAFETY LAWS. UTILIZE ALL TESTING AND PLACING/SPLC/UG FLAGGER-80 SAFETY EQUIP. CLEAN UP ANY WORK AREAS BEFORE LEAVING TO THE NEXT LOCATION, PLACING INSPECTOR PLC/SPLC/UG-8 ENSURE GRADE AND GROUND IS REPAIRED. ENSURE THAT ALL REQUIRED PERMITS ARE SPLICING —156 A UIRED AND ON HAND. FIBER DETAIL: TOTAL 48 FIBER=3,033' .sh C•ft Pamse TOTAL 48 FIBER PULL=1,337' TOTAL LASH=512' ondominiums ��°"> TOTAL PULL WITH TAILS=1,800' 1005 SW gsmAve Good Neighbor Center g OR sn2a r,Da TOTAL PLACED ALL=2,312' Summer aka ,� �. Pork Baaebai F. . PLACING UNITS: .panmenisQ: y Acme PrintSnop Henn sy PLACING/PULL FIBER INTO DUCT-787' 2422.201 MATERIALS: P co, unicauors Y PLACING/PULL FIBER INTO OCCUPIED-1013' 2422.201 Q swwaa oatou9 a Q Forenscucmnro. PLACING/LASH TO--512' 2421.201 and Tax Consulting PLACE/RISER=1 2421.201 100'-2' DUCT REVISIONS Dakota Knd'. FlyFace et , 9 Liquid Designs 4 PLACE/BORE CONDUIT-50' 2441.001 (PLACE/BORE=50') New Star Airport Shuttle9 : T PLACNG/PLACE CONDUIT IN TRENCH-50' 2441.001 (PLACE/HAND—DIG-50') PLACING/HAND DIG TRENCH-50' 2441.001 (PLACE/PULL FIBER=100') eToa+s 2:.r' PLACE/AE FIBER TERMINALS-1 2421.201 CLOSURES=3 PLACE/UG FIBER TERMINALS-4 2422.201 AE 48 CLOSURE=1 SPLICING UNITS; UG 48 CLOSURE=2 O SPLICE/MANHOLE SET—UP-1 2422.201 (COMMON) SNOWSHOES=3 2KREMOTE SPUCE/AE FIBER SET—UP-1 2421.201 (COMMON) U—GAURDS=1 pcoocToaQ 6 srv �%Rtl SPLICE AE REARRANGEUCLOSURE-22422-201 LOSURE 2SPUCE/UG FIBER SET- -2264 1.000 OMM(COMMON) 60PORT 00'NAL5=5 It Greerbur-gTownhori SWGmienbng SPUCE/PLACE AE CLOSLI 2421.201 12 PORT STRAND MOUNT-1 CloseT seDeais C. SPLICE/PLACE UG CLOSURE=-2 2422.201 12 PORT 50'=2 ziply rron.,tat D SPLICE/FIBER UG LESS THAN 48=72 2422.201 (COMMON)12 PORT 500'=1 r ]] ® B1r SPUCE/FTBER UG LESS THAN 48-26 24201 fiber � e SPLICE/FIBER AE LESS THAN 48-72 6421.01.000 (COMMON) SPLICE/FIBER AE LESS THAN 48-44 2421.201 5513035 ASHBROOK VILLAS Windmeoi% Apartmmta Tunes hxnn n..le.d..f, fmx PROJECT 5513035 CO.AREA. TIGARD NUMBER: EXCH.CODE. OR PUC TIGARD DRAWN DATE: FZRUSSELL WELLS CNTY: 5513035 ASHBR001{VIt1AS 5'132022 PHONE:503-312-7330FILE: SCALE, 1:117.7 ITAXDISTRICT:— I DWG 2 7 TNNSHP. Im. 17r. — SW �5TFT AVE—- SEE SHEET#2 386 08.2006 0 250491 C1135C18537 _____ _ YJD 216 i ZIPLY FIBER —� TGRDORXA FC2041,183-192+ TGRDORXA H4003,155-167+ X0.168+ w� TGRDORXA H4003,169-310+ TGRDORXA FC2041,259-264+ X0.173-216 32099 C1135D18536 LU I ZIPLY FIBER (NEW COUNT) Q Mi pie,CAUTION Powe, I YJD 216 oKMeee TGRDORXA FC2041,183-192+ TGRDORXA H4003,155-167+ L0 XD,168+ 0 32098 32098 'STOP ,Pd LOOK UP' I TGRDORXA H4003,169-310+ � ZIPLY FIBER rn I I EXISTING COUNT TGRDORXA FC2041,259-264+ � ( ) i 3 i XD.173-180+ 338 08.2006 j TGRDORXA H4003.397-432 YJD 216 TGRDORXA FC2041,183-192+ i Li l c� TGRDORXA H4003,155-167+ > XD,168+ � I a I TGRDORXA H4003,169-310+ °' = TGRDORXA FC2041,259-264+ LID i o nl XD,173-216 3 M COI (NEW COUNT) bore 667 between _ as YJD 216 MH 3 & MH 4, I TGRDORXA FC2041,183-192+ UNITS/ACCT CODES \ 32097 C1135D 8 a ZIPLY FIBER TGRDORXA H4003,155-167+ place fiber s XD,168+ TGRDORXA H4003,169-310+ IBJ TGRDORXA FC2041,259-264+ la XD.173-180+ TGRDORXA H4003 TGRDORXA H4003.397-432 _ FDH 48/432 (EXISTING COUNT) p `�� IN:TGRDORXA FC2041,169-172+ (SPLICE TO NEW 48 FIBER) ` �`� h XD,129-438+ P TGRDORXA FC2041,173-182 278 08.2006 ��` B �C \ F 6 I OUT:TGRDORXA H4003,1-432 YJD 216 �' ' TGRDORXA H4003 TGRDORXA FC2041,183-192+ \\ i TGRDORXA H4003,155-167+ '\ X0.168+ bore 346' between 7GRDORXA H4003,169-310+ � S�,j, \� , Fel TGRDORXA FC2041,259-264+ Q ( GR \ \\ Pvc �" MH 4 & HH, place XD.173-216 = FF,V `\ \ 34 , ° fiber (NEW COUNT) I e�RG `\ I ` \`�\ w� (SPLICE TO NEW 48 FIBER) 0) YJD 216 TGRDORXA FC2041,183-192+ U) TGRDORXA H4003,155-167+ , F� 1416' oe XD,168+ 0 48-FIBER 48 \ ? REVISIONS TGRDORXA H4003,169-310+ I XD,1-12+ \ cc ,,v FC2041,259-264+ i TGRDORXA H4003,397-432 XD.173-180+ (PLACE/PULL = 1,013') ® TGRDORXA H4003.397-432 + (LEAVE 100' COIL IN HH AND MH 300) (SPLICE TO FDH=36 FIBERS) (SPLICE TO EXISTING FIBER IN MH 300) wERNi REQUIRED MuANHOLE DETAIL SHEETS 38c 4 P\� FIBER , MATERIALS DETAIL SHEET#5 ���" ziply i GENERAL CONSTRUCTION NOTES: MANY FACILITIES AND CABLES ARE OMITTED FOR CLEARITY. ALWAYS UTILIZE ALL PERSONAL 5513035 ASHBROOK VILLAS PPE. PROVIDE APPROVED TRAFFIC CONTROL PLAN. ALWAYS GET LOCATES BEFORE ANY AND ALL DIGGING. ATTENTION HIGH VOLTAGE OVER HEAD POWER ALONG THIS ENTIRE WORK ---- AREA. ANY CHANGES OR ADDITIONS NEED TO BE PRE—APPROVED BY THE LOCAL PROJECT c.o.AREA: ncARO ENGINEER. FOLLOW ALL LOCAL AND FEDERAL SAFETY LAWS. UTILIZE ALL TESTING AND NUMBER: 5513035 EXCH.CODE: OR PUC TiGARD SAFETY EQUIP. CLEAN UP ANY WORK AREAS BEFORE LEAVING TO THE NEXT LOCATION, DRAWN DATE ENGR: RUSSEawE«s CNTY ENSURE GRADE AND GROUND IS REPAIRED. ENSURE THAT ALL REQUIRED PERMITS ARE \ 51132822 PHONE:503312-7530 FILE T51K5ASHBROCKVivas A UIRED AND ON HAND. SCALE 1:10O TAxDisTRicr- Bwc a 7 \ __ F1 TNNSHP: --- RNG — SEC. — 10940 GRQ1p X03 / bore 50' place fiber. = I W 95TH AV J_ M k04 ORkq 630 — \, 00 IS 9LONGSTAF ST Soo, \ \ L / 0950 SW 95TFT'AV o SW LON�G(S�T�AFF ST Z x CAUTION .. 1D995 - P1TU1 a� I PLC /PULL— SW 95TH ® 13149'-2LC/PUL L) PLC1PULL)E 8-2" 64'-2" n , / TRACT A BF 'STOP Ond LOOK UP' wr+s'nr,aawvEc I?- ✓ RO R1 363 3 1 6 M \ 10895 SW 95TH F3 i F4 8 '9 12X H 3 1 p 0 A \ 31008 C1135C6794 J p0 8 4 Y 40 + 11025 SW T T 95TH ZIPLY FIBER a OD 7 9 1 11 12 2 + OR2 3, 61432.1L 11055 SW 95TH (PLACE NEW RISER) m �� 6 13 14 15 16 17 8 19 20 210 2 23 � 2+ X A'p6{ ORE -)a g8 f 1p3P NgOp3'399� W F 50'-2" 5 R9� SSFtP MOVNZ z w�X rn 3 _ A .,�,°�° — ZG p1D c0 F3 355 a,°- .°°°° F4 447 �CDe ORS F Z w 48 FIBER 48 48 FIBER 48 12 P PZ n 002 XD,1-22+ XD,1-30+ TGRDORXA H4003,407-432 TGRDORXA H4003,415-432 0 0o 1 (PLACE SNOWSHOE 100' ® POLE) (PLACE/PULL=224') UNITS/ACCT CODES 111085 SW 95TH = (PLACE NEW RISER) (LEAVE 100' COIL IN 1ST & LAST HH) < NI (LINTO DUCT=100') (PLACE SPLICE(LEAVE 00' COIL IN HH) I (SPLICE FIBER) EAVE 11115 SW 95TH 11 I 100'-2" DUCT (SPLICE FIBER)11145 SW 95TH 31009 C1135C406 (PLACE/BORE=50') ZIPLY FIBER (PLACE/HAND-DIG=50') (PLACE/PULL FIBER=100') i > a ' MENTS z I0 •' COAUTION xx ,vitt voII vo.er 0 Circil.O.�naad N F2 815' a 48-FIBER 48 'STOP and LOOK UPS .J. XD,1-12+ TGRDORXA H4003,397-432 w o� (PLACE/LASH=512') a overlajH) i to Ci. (PLACE SNOWSHOE 100' COIL 1ST & LAST POLE) o existinpath (PLACE AE CLOSURE LAST POLE) REVISIONS o' 512' F (SPLICE FIBER) i rn 3 �`° SW NORTH DAKOTA ST (NEW COUNT) ------ (SPLICE TO NEW NORTH) i . CAUTIONiMANH0LE DETAIL SHEETS#38c#4 YJD 216 ° pe vc,eme.owneoeTGRDORXA FC2042+TGRDORXA H40037+ o�t� FIBER MATERIALS DETAIL SHEET#5 ziplXD,168+ V I OP and LOOK UPTGRDORXA H40030+ Ll fiber TGRDORXA FC20464+ iQ GENERAL CONSTRUCTION NOTES: XD.173-180+ I= MANY FACILITIES AND CABLES ARE OMITTED FOR CLEARITY. ALWAYS UTILIZE ALL PERSONAL 5513535 ASHBROOK VILLAS TGRDORXA H40032 a PPE. PROVIDE APPROVED TRAFFIC CONTROL PLAN. ALWAYS GET LOCATES BEFORE ANY AND irn ALL DIGGING. ATTENTION HIGH VOLTAGE OVER HEAD POWER ALONG THIS ENTIRE WORK ---- AREA. ANY CHANGES OR ADDITIONS NEED TO BE PRE-APPROVED BY THE LOCAL PROJECT CD.AREA TIGARD I� ENGINEER. FOLLOW ALL LOCAL AND FEDERAL SAFETY LAWS. UTILIZE ALL TESTING AND NUMBER. 5513035 FXCH.CODE ORPJC nGARD SAFETY EQUIP. CLEAN UP ANY WORK AREAS BEFORE LEAVING TO THE NEXT LOCATION DRAWN DATE ENGR RussELJWEUS ONtr 5siMASH13KNVILU,S SW 95TH AVE I ENSURE GRADE AND GROUND IS REPAIRED. ENSURE THAT ALL REQUIRED PERMITS AR 5)lKD22 PHONE2 ,503.312-733D FSE, A UIRED AND ON HAND. scue, taoo TAx DIsrR cr:- DWG a of SEE SHEET#1 rNNssdR - ING - ISEC -- TGRDORXA H4003 FDH 48/432 IN:TGRDORXA FC2041,169-172+ XD,129-438+ TGRDORXA FC2041,173-182 OUT:TGRDORXA H4003,1-432 MD:1626-1650 UNKNOWN DUCT UGAEF25-2 MD:1626-165 8221 � 1-1550 UGAEF25-2 50-2 MD:1601-1625 MD:1476-1500 UGAEF25-2 UGAEF25-24 4 5 TO H4003 0 MD15ODD 401-16500 UNITS/ACCT CODES F1 UGAEF4-24 o cu C o T1022:25-48N =o YGD24-SM o FC2041:169-192 o~ FOC 24 SM 041:289-31 + o C2041:169- 4 216 SM0000000 0 0 XD1-24+FC2041:289-312+XD49-120+ MD:1551-1600 F1 1416' XD121-168+FC2041:217-264 UGAEF50-2 FOC 216 SM 48-FIBER 48 MH4 L75 XD,1-12+ MH299 96+26 TGRDORXA H4003,397-432 5106TA 7880490 (PLACE/PULL = 1,013') 5460-U1S1W35D (LEAVE 100' COIL IN HH AND MH 300) SW GREENBURG & 92ND AV (SPLICE TO FDH=36 FIBERS) REV SAS 08/24/06 (SPLICE TO EXISTING FIBER IN MH 300) M H 2 9 NOT SURE WHICH SPECIFIC DUCT GOES TO THE FDH. PLEASE MARK UP PRINT WITH DUCT USED. RECORDS MAY NOT BE 100%ACCURATE FOR THIS MH. ROUTE SEEMS TO GO FROM THE FDH TO REVISIONS MH 299 THEN TO MH 300.THERE MAY BE A DUCT DIRECTLY TO MH 300 FROGS AND RECORDS ARE NOT CLEAR. CHOOSE THE BEST ROUTE AND CORRECT RED RECORDS. SPLICE FOR 216 FIBER MAY BE IN 299 OR IN THE 300. FROGS SHOWS 300 THE MH DETAIL IS CONFLICTING. ziply fiber 5513035 ASHBROOK VILLAS NUMBER 5513035 Co EA: TIGARD EXCH.CODE. OR PUC TIGARD 3 DRAWN DATE ENGR RUSSELL WELLS CN' 5513035 ASHBROOK VILLAS SN312022 PHONE SO&312-7330 FILE SCALE: 1:100 TAX DISTRICT:-- DWG 5F 7 TWNSH° — RNG. — SE: — TAIL 70700 H400 :157-160 NOT SURE WHICH SPECIFIC DUCT GOES TO THE FDH. PLEASE MARK UP PRINT WITH DUCT USED. TAIL #70699 RECORDS MAY NOT BE 100%ACCURATE FOR THIS MH. ROUTE SEEMS TO GO FROM THE FDH TO H400 :161-164 MH 299 THEN TO MH 300.THERE MAY BE A DUCT DIRECTLY TO MH 300 FROGS AND RECORDS ARE TAIL #70698 NOT CLEAR. CHOOSE THE BEST ROUTE AND CORRECT RED RECORDS. SPLICE FOR 216 FIBER MAY 003:165-167+XD,4 BE IN 299 OR IN THE 300. FROGS SHOWS 300 THE MH DETAIL IS CONFLICTING. #70973 -' RSN24-SM H 4003:169-176+XD,9 11+ H 03,168+H4003,349-352+ 17-24 MD:1701-1800 MD:1801-1890+1 DD UGAEFI-2 (EXISTING COUNT) UGAF1-2 UGMDF50-7110 (SPLICE TO NEW 48 FIBER) 278 08.2006 100 C XD1-24+FC2041:289-312 YJD 216 1 TAIL #452 6 XD49-168+FC2041:217-264 TGRDORXA FC2041,183-192+ FOC 216 SM TGRDORXA H4003,155-167+ UNITS/ACCT CODES on 10 O O XD,168+ TGRDORXA H4003, 69- 10+ < MD:1401-1900+400DD MD:1401-1650+15ODD TGRDORXA FC20411259 3264+ o a UGAEF9-24 UGAEF4-24 XD.173-216 _ o `' _ (NEW COUNT) 02 0 (SPLICE TO NEW 48 FIBER) YJD 216 TGRDORXA FC2041,183-192+ TGRDORXA H4003,155-167+ 00 000 000 00 XD,168+ TGRDORXA H4003,169-310+ MD:15DD+1891-1900 TGRDORXA FC2041,259-264+ UGAEF25-2 XD.173-180+ F1 1416' 1 TGRDORXA H4003,397-432 48-FIBER 48 MI-13 L75 XD,1-12+ MH300 89+39 TGRDORXA H4003,397-432 5106TA 7880490 (PLACE/PULL = 1,013') 5460-U1S1W35C (LEAVE 100' COIL IN HH AND MH 300) GREENBURG RD E O 95TH AV (SPLICE TO FDH=36 FIBERS) ON UlSIW35C MH IS E/0 96TH AVE (SPLICE TO EXISTING FIBER IN MH 300) REV SAS 08/24/06 M H 7J REVISIONS ziply fiber 5513035 ASHBROOK VILLAS PROJECT NUMBER. 5513035 C.O.AREA TIGARD EXCH.CODE OR PUC TIGARD 4 DRAWN DATE ENGR RUSSELL WEE CN Y 5$13035 ASHSROOKVILLAS 5;112022 PHONE:503.312.7330 FILE: TIE iRB PUB SCALE. 1:100 TAX DISTRICT;-� ONG 6 OF 7 NlNSHP. - RNG - SEC'. -- FIBER DETAIL: TOTAL 48 FIBER=3,033' TOTAL 48 FIBER PULL=1,337' TOTAL LASH=512' TERMINAL DETAIL. TOTAL PULL WITH TAILS=1,800' TOTAL PLACED ALL=2,312' BBFTP 1036302 BBFTP 1036303 BBFTP 1036304 F1 1416' TGRDORXA H4003,426-432+ TGRDORXA H4003,418-425+ IN:TGRDORXA H4003,415-417+ 48-FIBER 48 XD,8-12 XD,9-12 XD,4-6 XD,1-12+ 12 PORT 500' 12 PORT 50' 6 PORT 500' TGRDORXA H4003,397-432 ADDRESSES: ADDRESSES: ADDRESSES: (PLACE/PULL = 1,013') SW LONGSTAFF SW LONGSTAFF SW LONGSTAFF/95TH (LEAVE 100' COIL IN HH AND MH 300) 1. 17 1. 9 1. 9425 LONGSTAFF (SPLICE TO FDH=36 FIBERS) 2. 18 2. 10 2. 10950 SW 95TH (SPLICE TO EXISTING FIBER IN MH 300) 3. 19 3. 11 3. 10940 SW 95TH 4. 20 4. 12 4. DEAD F2 815' 5. 21 5. 13 5. DEAD 48-FIBER 48 6. 22 6. 14 6. DEAD XD,1-12+ 7. 23 7. 15 TGRDORXA H4003,397-432 8. DEAD 8. 16 (PLACE/LASH=512') 9. DEAD 9. DEAD (PLACE SNOWSHOE 100' COIL 1ST & LAST POLE) 10. DEAD 10. DEAD (PLACE AE CLOSURE LAST POLE) 11. DEAD 11. DEAD (SPLICE FIBER) 12. DEAD 12. DEAD F3 355 BBFTP 1036306 48-FIBER 48 BBFTP 1036305 TGRDORXA H4003,399-406+ XD,1-22+ TGRDORXA H4003,407-414+ XD 9-12 MATERIALS : UNITS/ACCT CODES TGRDORXA H4003,407-432 XD,9-12 12 PORT STRAND MOUNT (PLACE SNOWSHOE 100' ® POLE) 12 PORT 50' (PLACE NEW RISER) ADDRESSES: ADDRESSES: 100'-2" DUCT (PULL INTO DUCT=100') SW LONGSTAFF SW 95TH (PLACE/BORE=50') (LEAVE 100' COIL IN HH) 1. 1 1. 10895 (PLACE/HAND-DIG=50') (SPLICE FIBER) 2. 2 2. 10965 (PLACE/PULL FIBER=100') 3. 3 3. 10995 CLOSURES=3 4. 4 4. 11025 AE 48 CLOSURE=1 F4 447 5. 5 5. 11055 UG 48 CLOSURE=2 48-FIBER 48 6. 6 6. 118085 XD,1-30+ 7. 7 7. 11115 SNOWSHOES=3 TGRDORXA H4003,415-432 8. 8 8. 11145 U-GAURDS=1 (PLACE/PULL=224') 9. DEAD 9. DEAD TOTAL TERMINALS=5 (LEAVE 100' COIL IN 1ST & LAST HH) 10. DEAD 10. DEAD 6 PORT 500'=1 (PLACE SPLICE CLOSURE=1) 11. DEAD 11. DEAD 12 PORT STRAND MOUNT=1 (SPLICE FIBER) 12. DEAD 12. DEAD 12 PORT 50'=2 12 PORT 500'=1 REVISIONS fiber 5513035 ASHBROOK VILLAS PROJECT RODRNUMBER. 513035 C,0.AREA, TIGARD EXCH.CODE'. OR POC TIGARD 5 DRAWN GATE ENGR RUSSELLG FILECNT5513035 ASHBROOK VILLAS 91312022 PHONE:50381273302G FILE, TIAIRP 91116 SCALE, 1:100 TABDISTRICT:-- IDw3 7 F ? 70SHP. - IRNG: - ISEC. -