PFI2022-00162 CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT
s COMMUNITY DEVELOPMENT Permit#: PFI2022-00162
13125 SW Hall Blvd.,Tigard OR 97223 503.715.2421 Date Issued: 06/01/2022
Parcel: SEG806
Jurisdiction: Tigard
Site address: 12765 SW KATHERINE ST
Subdivision: BELLWOOD NO.2 Lot: 113
Project: Comcast 12785 SW Katherine St
Project Description: Comcast proposes to remove existing Comcast pedestal then place new underground conduit/cable and
install new Comcast pedestal
Class of Work: FEES
Type 1 -Utilities(gas,electric, data) Description Date Amount
PFI Permit Fee 05/25/2022 $300.00
Owner: Total $300.00
REQUIRED INSPECTIONS
Call 503-639-4175 for the IVR inspection request line or visit the City of
PHONE: Tigard website at www.ligard-or-aov to schedule inspections online.
Contractor:
PHONE:
Applicant:
MITCH BURGHELEA
11308 SW 68TH PARKWAY
TIGARD,OR 97223
PHONE: 5037985785
Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact
information of responsible parties before beginning work.
Permittee/Applicant
Signature: /tSe_e application a,,
Issued By: r-YINYI 4.� lV 1VtO.I.i�(J
Special Conditions(See Attached) `Jf, r
Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY
Conditions for PF12022-00162
Type: Condition Name: Status: Severity:
PFI_Utilities 01 -WORK SITE REQUIREMENTS Applied Notice
Applicant must comply with all applicable provisions of federal and state law,the Tigard Municipal Code, and the terms of any
agreement with the City of Tigard regarding work to be done pursuant to this permit,
PFI_Udlities 02-WORK SITE AREA Applied Notice
The work area and approach roads shall be maintained in a clean condition,free from obstructions and hazards. The
spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited and
violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up and
suspension of work to accomplish clean-up.
PFI_Utilities 03-WORK SITE EROSION CONTROL Applied Notice
Prior to starting work, effective and approved erosion control devices must be installed and maintained meeting the Clean
Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to
accomplish effective erosion control.
PFI_Utilities 04-WORK SITE REPAIRS Applied Notice
Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings, mailboxes, etc. shall be
reinstalled or replaced,with like kind of material. Obtain City approval of restoration work.
PFI_Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice
Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices
[MUTCD]for Streets and Highways", U.S. Dept.of Transportation, FHWA,current edition,American Traffic Safety Services
Association[ATSSA], and Oregon Temporary Traffic Control Handbook[OTTCH].
PFI_Utilities 06-TRAFFIC CONTROL PLAN Applied Notice
Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work area.
Traffic control devices,flag persons,etc.,shall be in place prior to initiation of construction work and shall be effectively
maintained.
PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice
Public roadway shall not be closed to traffic,at any time,without obtaining written approval from the City Engineer. The
applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and area
wide Emergency Services: 503-629-0111 (Tigard Police Dept.,Tualatin Fire&Rescue)and to 503-962-8140 (Tri-Met)and
503-431-2345(Tigard School District)and other service providers impacted by such closure.
PFI_Utilities 08-TRAFFIC CONTROL ADVANCE WARNING Applied Notice
Advance warning of traffic disruption shall be provided to the public by placement of an approved advance notification sign at
each end of the construction area 72 hours(min.)before initiation of construction work.
PFI_Utilities 09-TRAFFIC CONTROL PROPERTY ACCESS Applied Notice
Access to existing properties shall be maintained at all times,including normal delivery service and mail service.Obtain City
approval of any access closures.
PFI_Utilides 10-TRAFFIC CONTROL WORK HOURS Applied Notice
Work is permitted in daylight between the hours of 7:00 a.m.to 7:00 p.m.Mon-Fri unless otherwise authorized by the City.
PFI_Utilities 11 -TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice
Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m.unless authorized by the City
Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m.to 9:00 a.m. unless authorized by the
City Engineer.
PFI_Utilities 12-TRAFFIC CONTROL MODIFICATION Applied Notice
The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to
assure public safety.
PFI_Utilities 13-DRAINAGE CONTROL Applied Notice
Drainage shall be controlled within the work site and shall not adversely affect adjacent private property, public property and
the receiving system. The City may at any time order corrective action and suspension of work to accomplish effective
drainage control.
PFI_Utilities 14-UTILITY NOTIFICATION Applied Notice
Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR
952-001-0100 through OAR 952-001-0080.Copies of said rules maybe obtained from the Center by calling 503-246-1987. If
you have any question about the rules,contact the Center. NOTE: Damage to utilities shall be corrected at the permit
holder's expense.
PFI—Utilities 15- UTILITY LOCATION CONFLICT Applied Notice
Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole before
digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at the
applicant's expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work with
affected utility agencies.
PFI—Utilities 16-TEMPORARY PATCH Applied Notice
A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance
approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is
liable for hazards or damage resulting from the prosecution of the work.
PFI—Utilities 17-REPAIR OF EXISTING FACILITIES Applied Notice
Work under this permit shall include repair of existing facilities(roads,ditches,etc.)as may be necessary, as determined by
the Inspector,to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit.
Corrective work shall be done at the applicant's expense.
PFI—Utilities 19-PRECONSTRUCTION MEETING Applied Notice
Before initiating any construction activity,the applicant shall coordinate with the City's inspector, <Insert Name>at<Insert
Phone#>,to establish a preconstruction meeting.
PFI_Utilities 20-NOTICE TO COMMENCE WORK Applied Notice
The applicant shall notify the City's Inspector twenty-four(24)hours prior to commencing work, prior to any staged inspection,
and after completing work covered by the permit.
PFI_Utilities 21 -PERMIT/PLAN ON SITE Applied Notice
A copy of the permit including a Certificate of Insurance,and all attachments,and a copy of the approved construction plan
and all amendments shall be readily available at the work area. All work shall conform to the permit terms,conditions and
provisions and to the City approved permit plans,and approved plan amendments and to the City's standards and
specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work
performance.
PFI_Utilities 22- DAILY INSPECTION REPORTS Applied Notice
Applicant shall submit daily inspection reports,on a weekly basis,to the City's Inspector.
PFI_Utilities 23-MONUMENT PROTECTION Applied Notice
Existing monuments, property corners,and survey markers shall be protected. Replacement shall be at the permit holder's
expense.
PFI_Utilities 24-VALIDATION OF MATERIAL/CONSTRUCTION Applied Notice
The City's Inspector may,at his discretion, require tests and or reports from the applicant to validate claims of material or
construction adequacy/compliance. Such tests/reports shall be provided at the applicant's expense.
PFI_Utilities 25-EMERGENCY CONTACTS Applied Notice
Provide to the City inspector,in writing,the names and 24 hour emergency telephone number of two(2)persons who have
authority to resolve problems,take corrective action and, in general,will be responsible in case of any emergency. The
applicant shall notify the City Inspector, in writing, of any/all assignment changes.
PFI—Utilities 26-RIGHT OF ENTRY/EASEMENTS Applied Notice
Applicant to obtain proper right-of-entry and/or easements prior to starting work. Proof of right-of-entry or properly executed
easements,shall be provided to the City. The City shall in no way be construed to be liable for the applicant's failure to obtain
or provide for proof of right-of-entry or easements.
PFI_Utilities 27-PRIVATE PROPERTY AGREEMENTS Applied Notice
Provide the City a copy of an executed agreement[s]from the owner for each private property disturbed by construction
activity.
PFI_Utilities 28-AS-BUILT DRAWING Applied Notice
1,2,3,4,5 28-AS-BUILT DRAWING
One as-built drawing showing all new public improvements, including any revision made to the previously approved
construction plans and,also,any improvement which may impact an existing public system or facility, shall be provided to the
City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance).
1,2,3,4,5 28-AS-BUILT DRAWING
One as-built drawing showing all new public improvements, including any revision made to the previously approved
construction plans and, also,any improvement which may impact an existing public system or facility, shall be provided to the
City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance).
One as-built drawing showing all new public improvements, including any revision made to the previously approved
construction plans and, also, any improvement which may impact an existing public system or facility, shall be provided to the
City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance).
PFI—Utilities 31 -OTHER Applied Notice
Other
City of Tigard PFI#: 2022-00162
ENGINEERING DEPARTMENT
Public Facilities Improvement (PFI) Permit
PROJECT INFORMATION
TYPE OF WORK
Project name:
12785 SW Katherine St
❑ TYPE 1-Franchise Utility Work
Brief description of project:
Comcast proposes to remove existing Comcast pedestal performed by NWN,PGE, or utility
agency
then place new underground conduit/cable and install new Comcast pedestal on ❑ TYPE 2-ROW Sidewalk/Driveway/Sewer
SE Katherine St & SW 128th Ave. Work performed for the purpose of
• Sidewalk installation or repair
• Driveway approach installation and repair
SITE INFORMATION • Sanitary sewer lateral installation and
Location (address if available):
12785 SW Katherine St main line tap
Tigard, OR 97223 SEG 806 ❑ TYPE3-Fithianull usevpppmalwhicent k
performed with land use approval which
includes any of the following.
• Subdivisions or Partitions
APPLICANT INFORMATION • Stre twidening
Name: Comcast • Mainline installation for sanitary sewer,
storm sewer, Tigard water, and Tigard
Mailing address: 11308 SW 68th Parkway water service area
City/State: Tigard, OR Zip: 97223 ❑ TYPE 4-Small Cel]Technology
Phone:
(503) 798-5785 ❑ TYPE 5-Tigard Triangle
Email: Mircea_Burghelea@cable.comcast.com Phone: (`503) 798-5785
NOTE: Type 1 and 2 applications may be
Contactname: Mitch Burghelea emailed to rowpermits-.tipard-or.p
Phone: (503) 798-5785 Email: Mircea_Burghelea@cable.comcast.com
CONTRACTOR INFORMATION ❑ Same as applicant
Name: Texstar Enterprises, LLC CCB Number: 228361
Mailing address: 14122 Arndt Rd City/State: Aurora, OR Zip: 97002
Phone: (503) 793-3140 Email: scott.boyles@texstarenterprises.com
ENGINEER INFORMATION
Name: K&B Technical Solutions
Mailing address: P.O. Box 2529 City/State: Clackamas, OR lir: 97015
Phone: (281) 923-8353 Email: permits@kbmail.net
ADDITIONAL INFORMATION
Estimated value of workis required(if over$5,000):$ (within the public right-of-wap)
Is work related to a LAND USE DECISION? ❑Yes N No Case number.
Cityof Tigard • 13125 SW I Iall Blvd. Tigard,Oregon 97223 • w%-wtigard-or.gov • 503-718-2421 • Page 1 of 4
APPLICANTS
NOTE: Person specified as"Applicant"shall be designated"Permittee" and shall provide financial assurance for
work,if required by the city pursuant to TMC 15.04.140.
* With the exception of a utility operating pursuant to a valid franchise or license with the City of Tigard,when the owner and the applicant
are different people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner
or an agent of the owner. The owner must sign this application in the space provided or submit a written authorization with this
application. Franchised or Licensed Utilities are not required to obtain the owner's signature on the application.
I,the applicant,certify that:
• To the best of my knowledge, all the information provided within this application package is complete and
accurate.
• The above request does not violate any recorded deed restrictions that may be attached to or imposed upon the
subject property.
• If the application is granted, I will exercise the rights granted in accordance with the terms and subject to all the
conditions and limitations of the approval.
Brad Rollins Digitally signed by Brad Rollins
Date:2022.04.1915:14:33-05'00' Brad Rollins 4/19/2022
Applicant's or authorized agent's signature Print name Date
Property owner's signature (if required) Print name Date
STAFF USE ONLN
Case No: p _ ,�l3�j�O' CM 4/19/22
�—' Permit fee: Received by: 1 Date:
Approved by: Date: 4`11?7/- ZP Notified by: Date: "{/ UCJ/IZO
City of Tigard • 13125 SW Hall w.
Blvd. • Tigard,Oregon 97223 • ww6gard-orgov • 503-718-2421 • Page 2 off44
DEVELOPMENT ENGINEERING FEES
Public Facility Improvement(PFI)Permit:
INITIAL PFI PERMIT FEE
Part 1: Requited submittal fee is 10%of the Net PFI Permit Fee.See below for calculations.Minimum of$300.
NET PFI PERMIT FEE
Part2: All non-water system improvements engineer's estimate X 7%(less the initial PFI Permit Fee).
WATER LINE CONSTRUCTION FEE
Part 3: All public water system improvements engineer's estimate X 12%.
FOR ONLY • ONLY
TYPE 4: SMALL WIRELESS FACILITY TYPE 1-3:DETAILED SUBMITTAL
CHECKLIST REQUIREMENTS
Does applicant have a right-of-way license? ❑Yes ❑No TYPE 1 AND TYPE 2-Must include a sketch
showing:
Under the wireless facilities standards,is the proposal ❑ Dimensions
considered?(check all that apply): ❑Small Cell ❑Macro ❑ Street Name
How many install sites are proposed as part of this permit
❑ Site Address
application?
TYPE 3-Must provide 4 sets of plans (sized 24 x 36
or 22 x 34) and an electronic version of all submittal
The proposed equipment is located on which of the following: items. The plans must that include:
❑Public Right-of-Way ❑Private Property
❑ Cover—Site,Vicinity,Abbreviation,Legend
If equipment is to be located on private property,describe the ❑ General Notes(City,Water,Sewer,etc.)
type&use: ❑ Street(Plan,Profile)
❑ Water,Storm and Sanitary(Plan Profile)
❑ Water Quality Facilities
❑ Grading
❑ Landscaping/Tree Plan
❑ Composite Utility Plan(Electrical,Phone,Gas, Storm,
Sanitary,Water,Signage,Street Lights,etc)
❑ Details
❑ Traffic Sight Distance
❑ Signing and Striping
❑ Street Light Plan and Photometric
❑ Engineers seal/signature
❑ Sheet label(project land use name,revision and plan
log block,dates and sheet numbers.)
❑ Engineers Construction Estimate
Additional Submittals
(per land use conditions,if applicable)
❑ Traffic Report
❑ Storm water Drainage Calculations
❑ Geotechnical Report
❑ Preliminary Access Report(Sight Distance)
❑ Proposed Plat
❑ Pathway Design
❑ Water Provider Approval
City of Tigard 13125 SW Hall Blvd. Tigard,Oregon 97223 • xvwwtigard-or.gov • 503-718-2421 • Page 3 of 4
" �
sw " �; I
Edge of?avement
Ditch �
n Streetlight , —•---•-----•— —r---
T �"°' t R.¢,ter.
�
I j
i T��ro'pS>t d�IN �i CIRC"
1
I j
A Existing House
m�
Existing
j
�r I g
F. I L1 • Driveway
a� I
cir I 1
ED.
rl
°, j Existing Shop
L
Powerpole
I la 95' 1
Fro a Llne
•---•--z-—-
I o Pte,•
Fire Hydrani(FH)
1
Scale: 1"=30'
I
TYPE I AND TYPE 2:
MINIUM SKETCH REQUIREMENTS (Put N/A if not applicable)
� I 1
� � I
North arrow Property lines&dimensions Existing utilities locations
(sewer,storm,water)
Street&street names All existing structures
Proposed work Existing curb or edge of pavement Utility&street light poles
Existing S/W or D/W apron Slope of property Trees
City of Tigard • 13125 SW I IA Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 Page 4 of 4
12785 SE KATHERINE ST z
PROJECT #: 976262
12785 SW KATHERINE ST "
N Q
W n
Z N IL
a"
A
IN
TIGARD, OR 97223 30
N �
O
U
4 .
PROJECT LOCATION
3
1+
gig
OWNER!APPLICANT DESIGN BY SHEET INDEX d y
COMCAST BHT DESCRIPTION
CONTACT:MITCH BURCHELEA:CONSTRUCTION SPECLALIST K60 TECHNICAL SOLUTIONS
P.O.BOX 2529 E
MOBILE:(503)79M785 97015 CB COVER SHEETMCINITY MAP � 8
CONTACT:LACKAMAS
LE ROW
EMAIL:MIRCEA BURGHELEA@COMCAST.COM CONTACT:KYLE BROWNING I RIGHT-0F-WAY PUN (n
MOBILE:(T19)2N-ISDB L LEGEND 6 TYPICALS
EMAIL:PERMITS@KBMAILNET -.
m'
C,,.ale.Ef011.YGItlB U� I
1
R1AlE I1�lEU ,
er MCREppNBMI1.EC1iVN CENTER.
TMUMErN aEa aRE eEi roRw rce pnR eexmiawE axeE.
_61CALUN YW CREGM4NCLPEICi
ME Z.
BYCRLLINO P£pREppll UtA1IY CS
VO!'FlCR'iOM CEHTEP 9OMN151lG1RMe Iaaa.La.eanl
11EOPECOi KnewwhalB below.
� E1
a
...I..e ...FxCRVAVRaroN. Lail beforeyou dig,
LMFRJ AuN1593E
'• ". -
$ a
Ay �
� a
W Wm 3
N
y
H.
C N � �K
DO �_
N—
DO
DIG UP AND REMOVE EXISTING ~
COMCAST VAMTIPEMSTAL LL
❑
PUCE NEW PEDESTAL ~
BM P _ __mc jT_. l S �r U
1 J
00RERRENLM TO PI-ACE M T2Fr COMU�TABA.-O MIN.D5'NEW MADE _
PULL NEW CABLJ�OUGH NEW COTAUIT
1 a q k
� LR37
1
SE KATHERINE ST `
n ch c/L cA--CA-CAL
\ aR
< S n
x w w Ut
rca
2 gn
,� wx Iw
sbE w Y��
c
Ba /w �.` wp S/w m.sry F mx
I
5/w � /
2 V+%c
�P =x
SCAI£.1-10' O `gyp$
V� E
1. ALL WORK MEAS TO BE RESTORED TO LIKE OR SETTER CONDITION.
2,UNDERGROUND UTILITIES HAVE BEEN ROTTED FROM AVAILABLE erg
H PROPOSED CONDUITS,FOR ALL UTILITY CROSSINGS N THE WM WATER FAC"MS,MUST = RECORDS AND FIELD OBSERVATIONS BUT ME NOT NECESSARILY EXALT.
MNNTMN A MIMAIM I.S VERTICAL SKIN TO SKIN CLEARANCE FROM WATER FAMITIES,ZMINIMUM �aT�Y ^��
VERTKAL SKIN TO SKIN CLEARANCE WHERE CROSSING 1W AND LARGER WATER LINES,HYDRAIRS,MIO yy ,+,�.. y„y o S.IT RI THE OD STRUCTKIN CONTRACTORS RESPONSIBRRY TO FIELD
INLLUDMG FACILITIES NOTED AS CRITICAL INFRASTRUGTURE WHERE APPLIGABLE IN THE NE\NEw,aro A C I e.r.ws+— u LOCATE ALL UNOERGROUND UTILITIES PRIOR TO CONSTRUCTION.
MMIMUA OFSHORQOMPL SKIN TO SKIN CLEARANCEWHEN PARALLELING WATERFACILD1ES PfD I rtwrMr�� w:w COMPLETEREPNROFMIYMDP MMAGESWCURREDSHUMATTHE swaremo
CONSTRUCTING WITHIN THE PRI OF MAINS,APPURTENANCES,HYDRANTS AND SERVICESRAETEAS. w.�rrwer.u,w EXPENSE OF THE CONRACTOR. CMFR�92.159SL
rn 3
LINETYPES SYMBOLS i NME LL
AERIAL CABLE JdNT USE PdE 0 MILE TAG =o N=
EXISTING CONDUIT JOINT WE POLE W/TRANSFORMER ®POLE TAG F m
NE ®POLE TAG
W fANWR POWER POLE W/TRANSFdLMER 3Ny Q
RIGHT-OF-WAY wow POWER POLE X POLE TAG N
EASEMENT ESNR CABLE POLE 0 POLE TAG ^F F
PUBLIC UTILITY EASEMENT M TELEPHONE POLE O POLE TAG LL
PROPERTY LINE EXISTING CONDUIT RISER
CENTERLINE cp PROPOSED CONDUIT RISER
FACE OF CURD Tac PEDESTAL ® OO O OO
EWE OF PAVEMENT ECP VAULTMANDHOLE
EWE OF CONCRETE I. NANHOLE e g
EWE OF GRAVEL Ea INLET ® O * i
EWE OF SIDEWALK s/- VALVE D< O C] Cl g K
EXCAVATION UM ----------- METER
SEWER HYDRANT
STORM - -- --sc— POWER TRANSFORMER ® 1SX36PEDESTAL
WATER w STREET LIGHT POLE 18XSbCfT6'(WWRWIERpR)
GAS TRAFFIC SIGNAL POLE Qp t8�05'X18'(BASE/NTERYOR) _
POWER ° SIGNAL CONTROLLER
TELEPHONE CROSS WALK SIGNAL Q
FIBER OPTIC --- - RAILROAD SIGNAL ae S
CAN —rATv TREE eO
TRAFFIC SIGNAL - ----TMs CULVERT
STREET LIGHT sLl gj`yS m
FENCE LINE 3f dp R
�m
GUARD RML ❑ Ca
RAILROAD TRACKS
BUILDING FOOTPRINT ~ $R+.
Oy
a
of
L
mocerR
CMFIt�D1B2-L59�a
Page 80 2011 Edition
6.3 Two-Lane, Two-Way Roads
Shoulder Work wl Minor Road Encroachment Diag. 300
Use this detail for non-freeway work which extends into a travel lane and
maintains a minimum 10 foot travel lane. If a minimum 10 foot travel lane
cannot be maintained, or when traffic cannot safely pass by in both lanes
simultaneously, use the appropriate lane closure diagrams—for example,
Diagrams 310 through 350.
A lane closure may be appropriate for conditions such as high traffic
volumes, high speeds, and inadequate approach sight distance to the work
space, or heavy equipment adjacent to the travel lane.
1. Use truck-mounted flashing warning lights on work and protection
vehicles. See Section 4.3—Lights and Lighted Signs for exceptions.
2. For added visibility, a truck-mounted arrow board or PCMS in caution
mode may be used.
3. Cones shall be placed along the entire length of the work space. If a
protection vehicle is used and work is in place one hour or less, the
taper and tangent devices may be omitted.
4. If the speed is 45 mph or higher, volumes exceed 2000 ADT, or there
is limited sight distance, consider placing cones or tubular markers on
centerline.
5. An arrow board in caution mode or truck-mounted PCMS with
"SHOULDER WORK"or other appropriate message may be used for
higher visibility.
Sign Spacing and Buffer Lengths(feet)
Posted Spacing Between Signs "Buffer"
Speed A 8 c Space
20 so
25 100 100 100 75
30 100
35 350 350 350 125
40 150
45 180
50 Soo Soo 500 210
55 250
60 285
65 700 700 700 325
70 365
Chapter 5 September 2016
2011 Edition Page 81
Shoulder Work wl Minor Road Encroachment Diag. 300
ROAD
WORK •
AHF1�D
•
Initial
Warring A •
Sign
•
(Options •
•
Protection Vehicle
w/TMA(both Optional)
See Chapter 4 • Buffer
10' •
minimum • ll3
•
A ROAD
M � NARROWS
(Optional)
B
ROAD
WORT(
AHEAD
Initial
Warning
Sign
September 2016 Chapter 5