Loading...
Plans Site/Plot Plan Not to scale NORTH Fan location on Northern exterior just east of the AC unit 32' 11740 SW Warner Ave #))• • Tigard OR 97223 25' Radon Exhaust stack on • northern exterior avoiding windows and other re- entry points. No roof penetration. _ Floor plan Not to scale NORTH 32' Fan location on 4 ► Northern exterior just Main sewer stack Suction point east of the AC unit location below basement slab Craw!spaceWWI t S ei 25' g GI Basement Storage Radon Exhaust stack on IF northern exterior avoiding windows and other re- 3", schedule 40 PVC entry points. No roof running across crawlspace penetration. connecting suction point to fan OFFICE COPY RECEIVED Radon Mitigation System APR 20Z% Project Information and Basic Scope kArYOF rIGMV p 3UILDING DIVISION Project Address: 11740 SW Warner Ave Tigard, Oregon 97223 Property Owner: Name: Scott Ketaineck Mailing Address: 11740 SW Warner Ave Tigard, Oregon 97223 Phone: 503-616-6839 Email: sketaineck@gmail.com Zoning: GC Contractor: Cascade Radon Inc. 12839 NE Airport Way Portland, Oregon 97230 Phone: 503-421-4813 Email: officeAcascaderadon.com CCB 180537 Contact: Wade Gervais / Division Manager 503-964-0818 wade@cascaderadon.com General Scope of Work: 1. Previous testing indicated elevated radon levels at 11740 SW Warner Ave Tigard, OR 97223 2. Installation to be a sub-soil / sub-slab depressurization radon mitigation system for the entire building. 3. Suction point to be dug 2' —4' feet deep and backfilled with clean gravel, no fines. Suction point location to be in the along the northern wall of the basement storage east of the water heater. 4. Vent piping to be routed north across the crawlspace to the northern exterior route via foundation penetration through the northern wall and then to above the roofline venting away from dormer windows and other re-entry points and avoiding any roof penetrations. See attached general cross-section diagram(s). 5. An electrical inline duct fan shall be connected to the vent piping on the northern exterior. See attached fan specifications. 6. See attached General Installation Notes for other system specifics. 7. Building Footprint: No change proposed. 8. Open yard area: No change proposed. Sub-Soil Depressurization System (no scale) Exhaust(Released Above Eave) Exhaust Stack on 41 House Exterk)ri — 'CAI' ' Schedule-40 ABS or PVC _ rA ( :\ I /i Exhaust Fan �/ Liv,r44 S(+A<E. (Rated for %/ Exterior Use or Enclosed) J i 110 volt rr i r —with disconnect V______ .� Ii _ Flexible i coupling ��—V— \•�-- ,. , l Ir-- r 1 Sealant �� / Strapping(or ��� Other Support) %/!/ 1?: Joist TM, �J rr i Suction T//, Pipe ---► 1_a a=lima=n=11=- ].,1d's $eAGe. • , . •,;a Sealant Around • Suction Pipe h T� Footing ' Open Hole Active Sub-Slab Depressurization (ASD) General Installation Notes: 1. System(s) to be Active Sub-Soil/Sub-Slab Depressurization (ASD). 2. All installations to comply with EPA protocols. 3. Exhaust fan(s)to be located so to be assessable for installation, maintenance, and future replacement, and in a vertical run of vent pipe. 4. Typical fan specs: Continuously running electric, inline duct exhaust fan(s) shall be used. 21W-150W, 60 hz, 115V, 1.5 amps, 60 cycle. 5. Vent piping shall be schedule-40 PVC or ABS, with a minimum 3-inch diameter. 6. Vent termination to be a minimum of 6 inches above the roof line/eave, as well as 2 feet above and/or 10 horizontally from any intake into living space. 7. All vent pipe joints/connections to be sealed and air-tight. 8. Vent pipe shall not have low points, and shall be sloped so as to allow condensate within pipes to flow back to the sub-soil suction point(s). 9. Electrical disconnect for any exhaust fan shall be located within sight of the fan unit. Electrical power supply for any fan unit to be drawn from un-switched building power. 10. When reasonably possible, a manometer(air pressure gauge) shall be installed on or near the negative side of the vent system, and shall be a visible and/or audible mechanism that is simple to read and interpret. 11. All penetrations through concrete slab flooring, or concrete perimeter foundations, shall be sealed as is reasonable. 12. All vent pipes penetrating through fire-rated walls and ceilings shall have a properly rated fire collar and/or equivalent. 13. All system components to be adequately secured: vent pipe every 8 feet vertically (min), and every 4 feet horizontally (min). 14. Systems shall be clearly labeled "Radon Reduction System" or the like. System shall also be labeled as to: a. Dated activated. b. Installers name. Sub-Soil Depressurization System (no scale) Exhaust(Released Above Eave) Exhaust Stack on 41 Exhaust Option 1: House Exterior' .... '��' Exhaust Steck through • Schedule-4C A House Interior ABS or PVC f � To Exhaust Fan �\ rm. Mounted In Attic Exhaust Fan 1 WA __,`T L.i v i r.►4 S <E (Elated for PM Exterior Use or Enclosed) 110 volt (—/ �� with disconnect V________A r Slope Horizontal Legs -- — JI / Down toward Sub-Slab Hole,to Permit Condensate Flexible Drainage Coupling nr 4 [-Floor �i IL—'k �� _ �� r Connection to Other r' -r — —.---- Suction Polnt(s), \',.. I n _ l L r If Any Sealant �����+ v /Strapping(or V Other Support) F.'.), Joist Y�':,: Suction %�/,s + Pipe - • . Sealant Around . . - .. Suction Pipe' Footing' '~r' peen Hole OFFICE COPY Installation and Operation Manual to 2019-0 7-1 7C Rev Date D 209 Manuel d'installation et d'operation RECEIVED API 7 lei.; vl i Y OF TIGARLr Rn2EC I R n 4 E CHNoio� IJILDING DIVISION Inline EC Radon Fan • Ventilateur pour radon en ligne EC PARTS IN THE BOX(Rn2ECI PARTS IN THE BOX(Rn4EC) Inline Radon Fan Rn, 1 pc Inline Radon Fan Rn, 1 pc Operation and Installation Manual, 1 pc LDVITM Couplings, 2 pcs Operation and Installation Manual, 1 pc PIECES DANS LA BOITE(Rn2EC) PIECES DANS LA BOITE(Rn4EC) Ventilateur pour radon en ligne Rn, 1 pc Ventilateur pour radon en ligne Rn, 1 pc Manuel d'installation, 1 pc Couplages LDVITM, 2 pcs Manuel d'installation, 1 pc • 2100(t, �^ COus HVI CERTIFIED F� ;.. 4.5 Rn2EC Rn4EC REGISTER* THIS PRODUCT TO ❑ .0 ❑ INCREASE YOUR PRODUCT ' 'it , WARRANTY BY AN EXTRA YEAR ... • registration.fantech.app ❑ ° in USA only Technical/Customer Support: •� fa n t e c h ° Support technique et service a la clientele United States Tel 800.747.1762 Canada Tel.:800.565.3548 • a systemair company 7 ® 0 0 (C-7‘‘\, _____,/ 0 Note Warning/Important note Information Technical information Practical tip Avertissement/Note Information technique Conseil pratique importante ODO NOT CONNECT POWER SUPPLY until fan is completely installed. Make sure electrical service to the fan is in the locked"OFF"position. 1. Fantech recommends installation of this product by a trained, licensed, certified mitigation professional. Incorrect installation will void any and all product warranties or liability. Verification of safe/acceptable radon levels after installation is required. Check your local code restrictions for additional safety measures that may be needed for proper code compliant installation. 2. This fan has rotating parts and safety precaution should be exercised during installation, operation and maintenance. 3.WARNING! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS -OBSERVE THE FOLLOWING: a Use this unit in the manner intended by the manufacturer. If you have any questions, contact your manufacturer's representative or contact us directly. b.CAUTION: Before installation, servicing or cleaning unit, switch power off at service panel and lock the service disconnection means to prevent power from being switched on accidentally. When the service disconnection means cannot be locked, securely fasten a prominent warning device, such as tag,to the panel. c. Installation work and electrical wiring must be done by qualified personfsi in accordance with all applicable codes and standards, including fire- rated construction. d.The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit's operation. Follow the heating equipment manufacturer's guidelines and safety standards such as those published by the National Fire Protection Association(NFPA), the American Society of Heating, Refrigeration, and Air Conditioning Engineers (ASHRAEJ and the local code authorities. e.When cutting or drilling into wall and ceiling, do not damage electrical wiring and other hidden utilities. f. Ducted fans must always be vented to the outdoors. 4.WARNING! Check voltage at the fan to see if it corresponds to the motor name plate. 5. For radon mitigation use only. DO NOT use to exhaust hazardous or explosive materials and vapors. 6. Do not use this fan with any solid state speed control device. GUARDS MUST BE INSTALLED WHEN FAN IS WITHIN REACH OF PERSONNEL OR WITHIN SEVEN(T1 FEET OF WORKING LEVEL OR WHEN DEEMED ADVISABLE FOR SAFETY. OThe ducting from this fan to the outside of the building has a strong effect on the air flow, noise and energy use of the fan. Use the shortest, straightest duct routing possible for hest performance, and avoid installing the fan with smaller ducts than recommended. Insulation around the ducts can reduce energy loss and inhibit mold growth. Fans installed with existing ducts may not achieve their rated air flow. ..++"'. fantech 3 DIMENSIONS B r A >1 1 vi 1C r F 41 D 1 Model/ A B C U F F G Modele Rn2EC 4 15/32(1141 10(254] 1 1/4(32) 9 1/4 12351 - - Rn4EC-3 5 7/8 11491 11 1/2(2921 1 1/4(321 9 1/4(2351 4(102) 3 1/2 1991 6(152) 14n4CC-4 5//911491 11 1/p(2921 1 1/4(321 9 1/4(235) 4(102] 4 1/2(1141 6 1152] (Dimensions in Inches(inml. Dimensions en ponces(mm1 INSTALLATION WIRING DIAGRAM Rn2EC-3&Rn4EC-3 are designed for use with 3"schedule 40 PVC pipe. - To reduce fan speed use a small screwdriver and turn Rn2EC-4&Rn4EC-4 are designed for use with 4"schedule 40 PVC pipe. potentiometer knob counter clockwise Prior to installation, the suction pipe should be terminated at the exterior wall.The suction pipe should be installed with slight incline to drain water Putentiometer 120 V Supply from the fan. _;L—_1; 1'1 1'1 1'1t; 71.1 7 0 0 0 0 0 0 y 0 0 0 itO y LT O 2 ,a Motor 0 DO NOT connect fan directly to building structure antech WARRANTY Five (5) Year Warranty This warranty supersedes all prior warranties DURING ENTIRE WARRANTY PERIOD: END USER, AS CREDIT TO DISTRIBUTORS ACCOUNT WILL BE Fantech will repair or replace any part which has a factory defect in PENDING INSPECTION AND VERIFICATION OF ACTUAL DEFECT BY workmanship or material. Product may need to be returned to the FANTECH. Fantech factory, together with a copy of the hill of sale and identified with RMA number. THE FOLLOWING WARRANTIES DO NOT APPLY: • Damages from shipping, either concealed or visible. Claim must be FOR FACTORY RETURN YOU MUST: filed with freight company, • Have a Return Materials Authorization IRMA) number. This may be • Damages resulting from improper wiring or installation. obtained by calling Fantech either in the USA at 1.800 747.1762 or • Damages or failure caused by acts of God, or resulting from improper in CANADA at 1.800.565.3548. Please have bill of sale available. consumer procedures, such as: •The RMA number must be clearly written on the outside of the car- 1. Improper maintenance ton, or the carton will be refused. 2. Misuse, abuse, abnormal use, or accident, and •All parts and/or product will be repaired/replaced and shipped back to 3. Incorrect electrical voltage or current. buyer; no credit will be issued. • Removal or any alteration made on the Fantech label control number OR or date of manufacture. The Distributor may place an order for the warranty part and/or product •Any other warranty, expressed, implied or written, and to any conse- and is invoiced. The Distributor will receive a credit equal to the invoice quential or incidental damages, loss or property, revenues, or profit, only after product is returned prepaid and verified to be defective. or costs of removal, installation or reinstallation, for any breach of warranty. FANTECH WARRANTY TERMS DO NOT PROVIDE FOR REPLACEMENT WITHOUT CHARGE PRIOR TO INSPECTION FOR A DEFECT. WARRANTY VALIDATION REPLACEMENTS ISSUED IN ADVANCE OF DEFECT INSPECTION ARE •The user must keep a copy of the bill of sale to verify purchase date. INVOICED, AND CREDIT IS PENDING INSPECTION OF RETURNED •These warranties give you specific legal rights, and are subject to an MATERIAL. DEFECTIVE MATERIAL RETURNED BY END USERS SHOULD applicable consumer protection legislation. You may have additional NOT BE REPLACED BY THE DISTRIBUTOR WITHOUT CHARGE TO THE rights which vary from state to state. Limitation of Warranty and Liability This warranty does not apply to any Fantech product or part which has negligence, defect incorrect advice or other causes, shall Fantech be lia- failed as a result of faulty installation or abuse, incorrect electrical con- ble for special or consequential damages, including, but not limited to, nections or alterations made by others, or use under abnormal operating loss of profits or revenue, loss of use of equipment or any other associ- conditions or misapplication of the product or parts. We will not approve ated equipment, cost of capital, cost of substitute equipment, facilities for payment any repair not made by us or our authorized agent without or services, downtime costs, or claims of customers of purchase for prior written consent. The foregoing shall constitute our sole and exclu- such damages. Fantech neither assumes or authorizes any person to sive warranty and our sole exclusive liability, and is in lieu of any other assume for it any other liability in connection with the sale of product(s) warranties, whether written, oral, implied or statutory. There are no or part(s). Some jurisdictions do not allow the exclusion or limitation of warranties which extend beyond the description on the page hereof. In no incidental or consequential damages so the above limitations and exclu- event, whether as a result of breach of contract, or warranty or alleged sions may not apply to you. Warning Fantech products are designed and manufactured to provide reliable per- life support ventilation system where failure could result in loss or injury, formance, but they are not guaranteed to be 100%free from defects. the user should provide adequate backup ventilation, supplementary nat- Even reliable products will experience occasional failures and this possi- Ural ventilation, failure alarm system, or acknowledge willingness to bility should be recognized by the user. If these products are used in a accept the risk of such loss or injury. fantech 5 © oosØ III Note Avertissement/ Information Information Conseil Note imortante technique pratique /1100 NE PAS BRANCHER A L'ALIMENTATION ELECTRIOUE avant('installation complete du ventilateur. Assurez-vous que['alimentation electrique du ventilateur est en position hors tension verrouillee(OFFI. 1. Fantech recommande ('installation de ce produit par un professionnel de('attenuation forme, agree et certifie. Une installation incorrecte entrainera I'annulation de toutes les garanties ou responsabilites du produit. La verification des niveaux de radon securitaires/acceptables apres ('installation est requise. Verifiez les restrictions de votre code local pour les mesures de securite supplementaires qui peuvent etre necesseires pour une installation conforme au code approprie. 2. Ce ventilateur comporte des pieces rotatives; it est essentiel de faire preuve de prudence pendant('installation, le fonctionnement et I'entretien. 3. AVERTISSEMENT! POUR REDUIRE LE RISQUE D'INCENDIE, D'ELECTROCUTION OU DE BLESSURES, VEUILLEZ RESPECTER LES REGLES SUIVANTES : a. Utilisez cet appareil de la maniere prevue par le fabricant. Si vous avez des questions, communiquez avec le representant du fabricant ou directement avec nous. b. MISE EN GARDE : Avant d'installer, de reparer ou de nettoyer l'appareil, coupez l'elimentation electrique au panneau de service et bloquez les dispositifs de sectionnement pour eviter que('alimentation ne soit retablie par accident. Si les dispositifs de sectionnement ne peuvent pas etre bloques, apposez une note d'avertissement bien visible, comme une etiquette, sur le panneau de service. c. Tous les travaux relatifs a ('installation et aux fill electriques devraient etre effectues par un technicien qualifie, conformement aux normes et aux reglements en vigueur, y compris les travaux de construction classes resistants au feu. d. Le fonctionnement de cet appareil pourrait modifier la circulation d'air de combustion necessaire au fonctionnement securitaire des appareils de combustion. Suivez les consignee du fabricant pour les appareils de chauffage et respectez les normes de securite comme celles etablies par la National Fire Protection Association (NFPA), la American Society for Heating, Refrigeration and Air Conditioning Engineers [ASHRAE)ainsi que les codes des autorites locales. e. Lorsque vows coupez ou percez un mur ou un plafond pour('installation de('appareil, assurez-vous de ne pas endommager le cablage electrique et les autres services publics caches. f. Les conduits d'air des ventilateurs doivent toujours etre eventes a I'exterieur. 4. AVERTISSEMENT!Verifiez la tension du ventilateur pour confirmer qu'elle correspond a celle inscrite sur la plaque signaletique du moteur. 5. Uniquement pour la mise en oeuvre de mesures d'attenuation du radon. NE PAS utiliser pour evacuer des vapeurs ou des substances dangereuses ou explosives. 6. Ne pas utiliser cet appareil avec une commande de vitesse a semiconducteurs. DES DISPOSITIFS PROTECTEURS DOIVENT ETRE INSTALLES SI LE UENTILATEUR SE TROUVE A PORTEE DE MEMBRES DU PERSONNEL DU A SEPT(T1 PIEDS DU MOINS DU NIUEAU DE FDNCTIDNNEMENT OU LORSOU'ILS SONT JUGES NECESSAIRES POUR DES RAISONS DE SECURITE Le conduit de raccordement de ce ventilateur avec l'exterieur de l'immeuble a un effet important sur le debit d'air, le bruit et la Dconsommation d'energie du ventilateur.Veuillez utiliser le conduit le plus court et le plus droit possible pour obtenir un rendement optimal, et evitez d'installer des conduits plus petits que ceux recommandes pour le ventilateur.L'isolation autour des conduits peut reduire les pertes d'energie et empecher la moisissure. Les ventilateurs instailes avec des conduits existants pourraient ne pas offrir le debit d'air nominal. .. fantech 6 INSTALLATION Le modele Rn2EC-3&Rn4EC-3 est congu pour un usage avec des conduits de PVC de serie 40 de 3 pa. Le madele Rn2EC-4&Rn4EC-4 est conpu pour un usage avec des conduits de PVC de serie 40 de 4 pa. Avant('installation, it Taut prevoir une sortie pour le tuyau d'aspiration sur un mur exterieur. Le tuyau d'aspiration devrait etre installe avec une pente legere pour drainer('eau du ventilateur. s4t, 4 { 1. 4,1 0y 4, 4: \ i r x 6 'rise NE PAS attacher le ventilateur directement dans la structure du hatiment.A SCHEMA ELECTRIQUE Pour reduire la vitesse du ventilateur, utilisez un petit tournevis et tournez le bouton du potentiometre dans le sens inverse des aiguilles dune montre. Potentiometre 120 V Approvisionnement o o P9 1•11191111 PI PI PM 0 0 0 0 0 0 11.1 li,/ it ail) a a7 : 4- z. o a Moteur r fantech 7 GARANTIE Garantie de 5 ans Cette garantie remplace toutes les garanties precedentes. DURANT MUTE LA PERIODE DE GARANTIE: L'UTILISATEUR FINAL L'EOUIPEMENT DEFECTUEUX RETOURNE PAR Fantech s'engage a reperer ou a remplacer toute piece presentant un L'UTILISATEUR FINAL, CAR LE COMPTE DU DISTRIBUTEUR NE SERA defaut d'usine en matiere de qualite d'execution ou de materiau. II sera CREDITE OU'APRES L'INSPECTION ET LA VERIFICATION PAR FANTECH peut etre necessaire de retourner le produit a I'usine Fantech, accompa- DE LA DEFECTUOSITE. gne dune copie du contrat de vente et du numero d'autorisation de retour. LES GARANTIES NE S'APPLIOUENT PAS DANS LES CAS SUIVANTS: • Dommages dus au transport(dissimules ou visiblesl. Les reclame- POUR RETOURNER UN PRDDUIT A L'USINE,UDUS DEVEZ: tions doivent etre faites a la compagnie de fret. • Obtenir un numero d'autorisation de retour; pour ce faire, communi- • Dommages dus au mauvais cablage ou a!'installation inappropriee. quer avec Fantech aux Etats-Unis eu numero 1.800.747.1762, ou eu • Dommages ou defectuosite causes par une calamite naturelle ou Canada, au numero 1.800.565.3548. Veuillez avoir votre contrat de resultant dune procedure irreguliere de I'acheteur, notamment vente a portee de la main. 1. Entretien irregulier •S'assurer que le numero d'autorisation de retour est lisible sur 2. Meuvais usage, usage abusif, usage anormal ou accident I'exterieur de la bone, sinon la boite sera refusee. 3. Tension ou courant electrique incorrect •Toutes les pieces et/ou le produit seront reperes ou remplaces puis • Enlevement ou toute modification du numero de contrble ou de la date retournes a I'acheteur. Aucun credit ne sera accords. de fabrication de!'etiquette Fantech OU •Toute autre garantie expresse, barite ou implicite, pour les dommages • Le Distributeur peut commander une piece ou un produit couvert par la accidentels ou indirects, perte de biens, de recettes, manque a gag- garantie; la facture lui sera envoyee. Le distributeur ne sera credite du ner ou coats relatifs a la depose, a !'installation ou a la reinstallation, montant de sa facture qu'apres que le produit a ete retourne port pays en cas de violation de garantie. et qu'il a ete trouve defectueux. CERTIFICATION DE LA GARANTIE: LES TERMES DE LA GARANTIE OE Fantech NE PREVDIENT PAS DE • L'utiliseteur doit conserver une copie du contrat de vents pour REMPLACEMENT SANS FRAIS AVANT CUE LA PIECE OU LE PRDDUIT confirmer la date d'achat. DEFECTUEUX AIT ETE INSPECTE. LES PRODUITS OU PIECES • Les presentes garanties vous donnent des droits specifiques reconnus REMPLACES AVANT L'INSPECTION DE LA DEFECTUOSITE SERONT par la loi et sont regies par les lois sur la protection du consomme- FACTURES ET LE MONTANT DU CREDIT EST FONCTION DE teur appropriees. II est possible que differents etats offrent d'autres L'INSPECTION DE LA PIECE OU DU PRDDUIT RETOURNE. LE droits, DISTRIBUTEUR NE DOIT PAS REMPLACER SANS FRAIS POUR Limites de garanties et de responsahilites Cette garantie ne s'epplique a aucun produit de Fantech ou A aucune des dommages dut a la negligence ou a des conseils incorrects ou piece detachee dont la defectuosite releve dune erreur d'instaliation ou autres causes, Fantech ne pourra etre tenu pour responsable des dom- d'ebus ou de mauvaise installation electrique ou dut A des modifications mages particuliers ou consecutifs, incluant mais pas limites aux pertes exterieures Cu utilisees dans des conditions anormales ou encore une et profits ou benefices perte de materiel on autres materiels associes. mauvaise installation du produit ou des pieces detachees. Nous Coat du capital, coat des equipements de remplacement, materiels ou n'approuverons aucun remboursement pour des reparations qui ne sent services, coat de temps d'arret ou les reclamations des clients pour de pas effectuees par un agent americain ou un agent autorise sans un tels dommages. Fantech ne delegue ou autorise aucune personne accord bait. Ce dernier constituera notre seule et exclusive garantie et d'assumer sa responsabilite sur la vente du produit ou des pieces deta- notre seule exclusive responsabilite et tient lieu de toute autre garantie chees. Certaines juridictions ne permettent pas('exclusion de la limita- ou bien ecrite ou orale implicite ou statuaire. Aucune garantie ne lion des dommages accidentels ou consecutifs ainsi ces limitations ci- sappliquera au-dela des descriptions faites de la page ci-dessus. En dessus et lee exclusions ne s'appliquent pas a vous. aucun cas, que ce soit pour une rupture de contrat ou de garanties ou • Avertissement Les produits de Fantech sont conqus et fabriques pour produire des per- blessures, les usagers devront avoir une source de ventilation de sec- formances fiables, mais it n'y a aucune garantie qu'ils soient 100% sans ours en addition a une ventilation naturelle, le defaut de systeme defaut. Les plus produits les plus fiables ont occasionnellement des d'alarme ou la connaissance de ces conditions entrainent sa responsabil- defectuosites et cette possibilite devraient etre reconnu par les usagers. its envers de telles pertes ou blessures. Si ces produits sont utilises comme une source de ventilation eu leur panne risque de mettre en danger des vies humaines ou entrainer des f' fantech Fantech reserves the right to make technical changes. Fantech se reserve le droll de faire des changements tech- For updated documentation please refer to www.fantech.net niques.Pour de la documentation e four s'il vows plait se referer au www.fantech net Fantech® 1110. fantech � a systemair company