Plans (5) BUP2021 -00053
0100 00 GENERAL DATA WALL CONSTRUCTION EXECUTION 23 00 00 HVAC : DESIGN/BUILD
GENERAL REQUIREMENTS, 1. FASTEN FRAMING MEMBERS TOGETHER A WELDING OR BY USING SELF-DRILLING OR SELF-TAPPING HVAC-BID PROCEDURE TENANT IMPROVEMENT \
SCREWS. WELDING SHALL CONFORM TO AWS D13 WELDING PROCEDURE. ELECTRODES AND SCREW
1. VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON DRAWINGS AND AT THE EXISTING BUILDING AND CONNECTIONS SHALL BE AS REQUIRED AND INDICATED IN THE DESIGN CALCULATIONS. DO NOT FIELD WELD 1. FOR BIDDING PURPOSES,THE HVAC CONTRACTOR WILL ASSUME THAT EXISTING HVAC EQUIPMENT IS IN 10
NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING THE WORK. MATERIALS LIGHTER THAN 18 GA. PROPER WORKING ORDER. ffA�A'0 #3082
2. CONTRACTOR AND ALL SUBCONTRACTORS SHALL PERFORM DUE DILIGENCE INSPECTION OF ALL EXISTING 2, PROVIDE ACCURATELY ALIGNED RUNNERS AT TOP AND BOTTOM OF PARTITIONS. ANCHOR TRACKS AS 2. INVENTORY EXISTING H.V.A.C.ROOFTOP UNITS AND SUBMIT TO ARCHITECT A CONDITIONS REPORT OF EACH V
CONDITIONS PRIOR TO SUBMITTAL OF A PROPOSAL.SUBMITTAL OF A PROPOSAL SHALL BE CONSIDERED INDICATED IN THE DESIGN CALCULATIONS. BUTT WELD JOINTS IN TRACKS OR SPLICE WITH STUD INSERTS. UNIT ^�•�RECEIVED Y� MARTIN W.HANSON
CONFIRMATION THAT SUCH INSPECTION HAS BEEN MADE,AND NO FURTHER COMPENSATION SHALL BE DUE f O r
THE CONTRACTOR FOR CLAIMS ARISING AS A RESULT OF FAILURE TO PERFORM SUCH INSPECTION. FASTENERS SHALL BE LEAST 3 INCHES FROM THE EDGE OF CONCRETE SLABS. 3. LIST TONNAGE OF EACH UNIT. I••�t v
CLA ,OREGON
3. CUT STUDS SQUARE AND SET WITH FIRM BEARING AGAINST WEBS OF TOP AND BOTTOM TRACKS. POSITION - HVAC'-DESIGN PROCEDURE FEB �. H YUYI
3. BY SUBMITTING A PROPOSAL,CONTRACTOR AND ALL SUBCONTRACTORS CERTIFY THAT THEY HAVE STUDS VERTICALLY IN TRACKS AND SPACE AS INDICATED IN DESIGN. DO NOT SPLICE STUDS. PROVIDE AT -'',. y�, `�-
EXAMINED THE SITE AND INCLUDED IN THEIR PROPOSAL ALL WORK NECESSARY TO COMPLETE THE WORK LEAST TWO FULL HEIGHT KING STUDS AT DOORS AND OTHER OPENINGS 2 FEET WIDE OR LARGER. PROVIDE h TI D/OR NEW EQUIPMENT TO DESIGN MECHANICAL H.V.A.C.SYSTEM PER DESIGN STANDARDS PACTRUST - � O
DESCRIBED OR REASONABLY IMPLIED IN THESE DOCUMENTS. THIS INCLUDES BUT MAY NOT BE LIMITED TO JACK STUDS OVER OPENINGS,AS NECESSARY,TO MAINTAIN INDICATED STUD SPACING. PROVIDE TRIPLEpl,t .BELO�. �!/ ('„
ALL MATERIALS AND INSTALLATION,DISPOSAL NS EXCESS MATERIALS(USEABLE FINISH MATERIALS SHALL BE STUDS AT CORNERS,POSITIONED TO RECEIVE INTERIOR AND EXTERIOR FINISHES. FASTEN STUDS AT TOP 2. PRIOR TO AWARD OF CONSTRUCTION CONTRACT,H.V.A.C.CONTRACTOR SHALL SUBMIT TO ARCHITECT FOR CITY OF TIGARD 1,` C vv
LEFT IN THE TENANT SPACE LA NOTED ON PLANS),CLEANING AND ALL PREPARATION OF SUBSTRATE AND BOTTOM TRACKS BY WELDING OR SCREWING BOTH FLANGES TO THE TRACKS.PROVIDE LONG LEG REVIEW AND APPROVAL A FULL DESIGN SCHEMATIC FOR THE TENANT SPACE INCLUDING BOTH BUILDING DIVISION OF O�
SURFACES PRIOR TO INSTALLATION,AS WELL AS FINAL CLEAN UP. TRACK AT TOP OF WALL TO ALLOW FOR DEFLECTION WHERE WALL MEETS STRUCTURE ABOVE. NEW/RENOVATED WORK AND SYSTEMS UNTOUCHED BY THE TENANT IMPROVEMENT AS APPLICABLE. Tenant.
4. IT IS THE INTENT OF THESE CONTRACT DOCUMENTS TO MATCH AND MAINTAIN EXISTING BUILDING 4. REMOVE EXISTING FLOORING AT NEW WALLS UNLESS SPECIFICALLY INDICATED BY ARCHITECT. INCLUDE THE FOLLOWING:
STANDARDS FOR ALL EXISTING PRODUCTS AND SYSTEMS. UPON DISCOVERY OF A DISCREPANCY TO THISd. DUCTING AND SIZES
INTENTION,THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY. 5. INSTALL ALL INTERIOR AND EXTERIOR GYPSUM BOARD PRODUCTS AND ACCESSORIES AS REQUIRED FOR P ROJ ECT #21100
5. FURNISH ALL NEW MATERIALS EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE. THE PROJECT. e. SUPPLY AND RETURN LOCATIONS AND CFM AT EACH GRILL OR DIFUSER Q UAD/EN T INC.
6. COORDINATE THE WORK OF ALL TRADES. PROVIDE CARPET"WALK-OFF MATS"TO PROTECT EXISTING 6. COMPLY WITH USG GYPSUM CONSTRUCTION HANDBOOK AND MANUFACTURER'S RECOMMENDATIONS. f. ROOF EQUIPMENT,SIZES AND LOCATIONS '
CARPETS. 7. FINISH QUALITY:
g. UNITS REQUIRING DUCTED SMOKE DETECTION
7. KEEP THE AREA OF WORK FREE OF GARBAGE AND DEBRIS ON A DAILY BASIS INCLUDING DOCK ACCESS AREA PROCESS TRADE NOMENCLATURE h. THERMOSTAT LOCATIONS AND ZONE/UNIT ASSOCIATED THEREWITH ^
AREAS AND COMMON AREA. FLOORS TO BE SWEPT OR VACUUMED DAILY. OFFICE/OTHER AREAS TAPE/2 FINISH COATS'/ SMOOTH FINISH TAPED(LEVEL 4) 1. ANY SUPPLEMENTAL EXHAUST FANS OR SPECIAL SYSTEMS OFFICE Cop); V
8. PROVIDE ADEQUATE PROTECTION TO ALL EXISTING IMPROVEMENTS INCLUDING BUT NOT LIMITED TO USG"FIRST COAT "SAND AFTER TAPE/FINISH COAT(S) J. ZONE DIAGRAM lr ^,
COMMON CORRIDORS AND STAIRS,BUILDING ENTRANCES,SUITE ENTRANCES,ETC. THE CONTRACTOR WILL NOTE:AT EXTREMELY DARK ACCENT WALLS PROVIDE LEVEL 5 FINISH. VJ
BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGES TO EXISTING IMPROVEMENTS DUE TO CONSTRUCTION HVAC DESIGN STANDARDS PROJECT NARRATIVE
ACTIVITIES. 8. FINISH EXPOSED INTERIOR GYPSUM BOARD WALLS AND CEILINGS SMOOTH STRAIGHT READY FOR FINISH AS THE FOLLOWING ARE MINIMUM DESIGN STANDARDS:
9. PROVIDE TEMPORARY SANITARY FACILITIES. CONSTRUCTION WORKERS SHALL NOT USE BUILDING SHOWN ON PLANS. +
1. 350 SQUARE FOOT PER TON(UNLESS OTHERWISE APPROVED IN WRITING BY PACTRUST). PROJECT CONSISTS OF REMODEL WORK TO 1,779 USABLE SF/'i,98 pL
RESTROOM FACILITIES. 09 53 00 SUSPENDED ACOUSTICAL CEILING - - �I"�pfvsMARD, ._ ..
2. ADDRESS LOADS BY SPECIFIC LOCATION AND USE,AS WELL AS CRITERIA PROVIDED TO PACTRUST BY EXISTING OFFICE SPACE
10.STORAGE AND STAGING OFCONSTRUCTIONMATERIALS SHALL BE LIMITED TO AREAS AS DESIGNATED AT 1. PRODUCTS: L,
PRE-CONSTRUCTION MEETING. UNDER NO CIRCUMSTANCES SHALL BUILDING UTILITY AREAS OR ANY OTHER TENANT PRIOR TO CONSTRUCTION: WORK SHALL INCLUDE BUT NOT BE LIMITED TO - FOR CODE COMpj,UNE
COMMON BUILDING AREA BE USED FOR STORAGE. a. GRID-PRELUDE 24 XL 15116"EXPOSED TEE(HEAW DUTY) a. EXTERIOR EXPOSURE AREAS • SELECTED DEMO OF EXISTING NON STRUCTURAL WALL�PPt'OYeat
11.ALL DIMENSIONS ARE TO FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. b. TILES-ARMSTRONG DUNE#1774,24 x 24 x 5/8"W1 BEVELED TEGULAR EDGE b. INTERIOR AREAS,SIZE AND USE • NON STRUCTURAL DRY STING NON STUDS WALLS 'TCI I •'
c. ACCESSORIES-MANUFACTURERS'STANDARD • SUSPENDED CEILINGS _
12.CONFIRM SIZES OF ALL OPENINGS REQUIRED FOR THE INSTALLATION OF STRUCTURAL,MECHANICAL, c. CONFERENCE/TRAINING ROOMS Petmlt� �
ELECTRICAL AND PLUMBING WORK PRIOR TO FRAMING OR CUTTING FOR INSTALLATION. 2. ALL TILE CUTS SHALL BE DONE WITH RAZOR SHARP KNIVES. CUT/TRIM TILE EDGE TO CREATE TEGULAR EDGE d. COMPUTER/SERVER AND TELEPHONE ROOMS TO HAVE PROVISION FOR LOW AMBIENT OPERATION • DOORS/FRAMES AND PAINTING f ? I - `� Q O
13.LEAVE THE PROJECT CLEAN AND READY FOR OCCUPANCY. CONDITION SO THAT CEILING TILES LAY FLAT. AND 24-HOUR USE.VERIFY NEED FOR A SEPARATE SPLIT SYSTEM TO MAINTAIN TEMPERATURE. �t�tCs� 4�C� ch
14.FILL ALL PAPER IN BREAK AREA. 3. TUNE UP GRID SYSTEM TO WITHIN PLUS OR MINUS 0.5 INCHES OF LEVEL OVER THE ENTIRE SPACE. 3. SYSTEM DESIGN CRITERIA-SIZE ZONES FOR 3-5 TON UNITS BASED ON USE&EXPOSURE CRITERIA. • ELECTRICAL DISTRIBUTION Lf F R U)
15.CLEAN ALL SUPPLY AND RETURN DIFFUSERS AT PROJECT COMPLETION. 4. BENT OR DAMAGED T-BARS TO BE REPLACED. PACKAGED OR SPLIT SYSTEM EQUIPMENT GREATER THAN 5 TONS SHALL BE SPLIT INTO MULTIPLE ZONES. • LIGHTING Suite M ()C) c
VAV OR WATER SOURCE HEAT PUMP SYSTEMS GREATER THAN 3 TONS SHALL BE SPLIT INTO MULTIPLE
5. REPAIR HOLES IN GRID FROM REMOVED WALLS. USE OF ARMSTRONG"BP ES-4"EXPANSION SLEEVE • PLUMBING B
16.UPON COMPLETION OF THE PROJECT,THE CONTRACTOR MUST PROVIDE A DETAILED CLOSEOUT PACKAGE ZONES. }� Data= �+� Y
PER INSTRUCTIONS INCLUDED IN THE CONSTRUCTION CONTRACT.RETENTION WILL BE HELP PER CONTRACT ACCEPTABLE. 4. ALL ENCLOSED ROOMS OR OFFICES TO HAVE DUCTED SUPPLY&RETURN GRILLES. ALL WORK TO MEET ADA REQUIREMENTS.
UNTIL THE COMPLETED CLOSEOUT PACKAGE IS RECEIVED AND HAS BEEN APPROVE BY THE CONSTRUCTION 09 65 19 RESILIENT FLOORING -LUXURY VINYL TILE
MANAGER,ARCHITECT,AND PROPERTY MANAGER. 5. UNITS: LENNOX,TRANE,YORK OR CARRIER-7 1/2-TON MAXIMUM UNIT SIZE. ANY UNIT IN EXCESS OF 7 1/2 - -
1. FINISH FLOORING TO EXTEND UNDER CASEWORK. TONS SHALL HAVE SPECIAL WRITTEN APPROVAL FROM PACTRUST. WORK INCLUDED BUT PERFORMED UNDER SEP:PERMIT
17.IT IS THE INTENT OF THE CONTRACT DOCUMENTS THAT THE CONTRACTOR PROVIDE A COMPLETE, 2. INSTALL TILES IN 113 OFFSET ASHLAR PATTERN U.N.O.
FUNCTIONING PROJECT INCLUDING ALL GENERAL, MECHANICAL AND ELECTRICAL CONSTRUCTION REQUIRED 6. HVAC UNITS EQUAL TO OR GREATER THAN 5-TONS TO HAVE DUCT SMOKE DETECTORS AND BE CONNECTED - IY
TO FULFILL THAT INTENT. ALL ITEMS REQUIRED SHALL BE FURNISHED AND INSTALLED,REGARDLESS OF 3. DO NOT WAX OR OTHERWISE SURFACE TREAT EXCEPT CLEANING. TO A MONITORING STATION WITHIN THE BUILDING. PLUMBING WORK 8 C) �
WHETHER OR NOT SHOWN ON THE DRAWINGS. W
4. USE SCHLUTER TRANSITIONS PER FLOORING TRANSITION DETAILS. 7. ECONOMIZER TO MEET CODE AND AS FOLLOWS: FIRE PROTECTION SPRINKLERINGQ
09 68 00 CARPET HEATING
co r-
18.ITEMS OR WORK NOT TO BE FURNISHED OR ACCOMPLISHED BY CONTRACTOR ARE NOTED"N.I.C.". z
a. 6 TONS AND ABOVE MUST HAVE ECONOMIZER. , VENTILATION &AIR CONDITIONING WORK
19."ALIGN"AS USED IN THESE DOCUMENTS,MEANS TO ALIGN THE FINISHED FACES OF ELEMENTS IN THE SAME 1. CARPET PLANK(12"X 36"OR 18"X 36") b. BAROMETRIC RELIEF ON 5-7 1/2 TON UNITS. ELECTRICAL WORK, BOTH LINE VOLTAGE AND LOW VOLTAGE '� c0 Q N N
PLANE,EITHER IMMEDIATELY ADJACENT TO ONE ANOTHER OR ACROSS AN OPENING. J cO cO
20.D0 NOT DISASSEMBLE SETS OF CONSTRUCTION DRAWINGS.DRAWINGS ARE INTERRELATED.
a. INSTALL IN RANDUM ASHLAR PATTERN U.N.O. c. 8 TONS AND ABOVE MUST HAVE POWER EXHAUST. O F-
21.SUBMIT SAMPLES OR DRAW DOWNS FOR ALL FINISHES REQUESTED TO THE ARCHITECT OF RECORD WITHIN 2. USE SCHLUTER TRANSITIONS PER FLOOR TRANSITION DETAILS. d. 1 1/2 THRU 4-TON OSA INTAKE WITH DAMPER. C In In xO O
TWO WEEKS OF PROJECT AWARD.SAMPLES SHOULD BE NO LARGER THEN 11 X 17 AND TAGED WITH 09 9123 PAINTING 8. ALL UNITS TO MEET OR EXCEED CURRENT ENERGY EFFICIENCY CODE REQUIREMENTS. c a L0
MANUFACTURES LABEL.PRODUCTS INSTALLED WITHOUT APPROVED SAMPLES ARE SUBJECT TO INTERIOR: 9: DISTRIBUTION DUCTWORK:
REPLACEMENT AT CONTRACTOR COST.AN APPROVED SUBMITTAL DOES NOT CHANGE THE CONTRACTUAL -
REQUIREMENT TO PROVIDE THE SPECIFIED ITEMS UNLESS SPECIFICALLY NOTED AS A SUBSTITUTION BY THE 1. WALLS: a. SPIRAL DUCT PERMITTED ONLY IF EXPOSED. BUILDING INFORMATION_ TENANT INFORMATION
CONTRACTOR AND SPECIFICALLY APPROVED BY THE ARCHITECT AS SUCH.REPLACE SUCH PRODUCTS AS ED
DIRECTED AT CONTRACTOR'S COST. a. PRIME NEW DRYWALL WITH MILLER PAINT HIGH-BUILD"SUPER SEAL"PRIMER. b. 26 GAUGE OR TO SMACNA STANDARDS WHERE DUCT IS CONCEALED ABOVE A CEILING. OWNER: PACIFIC REALTY ASSOCIATES,L.P. TENANT: QUADIENT, INC.
22.SUBMIT COMPLETE SHOP DRAWINGS FOR MILLWORK,SPECIAL SYSTEMS,MECHANICAL,ELECTRICAL AND b. NEW AND EXISTING DRYWALL TO BE FINISHED TO ACHIEVE UNIFORM COVERAGE WITH MILLER PAINT c. WRAP CONCEALED SUPPLY DUCTWORK IN NON-CONDITIONED AND SEMI-CONDITIONED SPACE WITH 15350 SW SEQUOIA PKWY#300 a
-4- . - - . .
PLUMBING SYSTEMS(INCLUDING FIRE PROTECTION SYSTEMS). SUBMIT A MINIMUM OF TWO COPIES OF ALL XX WITH A TIGHT ROLLER STIPPLE FINISHRESTROOM FINISHES TO BE MILLER PAINT 1705XX S/G MINIMUM R42 INSULATION WITH FSK BARRIERPORTLAND,OR 97224 OCCUPANCY AREAS & LOADS: VALIDITY OF RMIT 00
120
SHOP DRAWINGS FOR REVIEW AND APPROVAL TO THE ARCHITECT OF RECORD.ARCHITECT WILL RETAIN ONE LATEX ENAMEL. d. HANGERS 12 GAUGE WIRE OR 18-GAUGE 1"WIDE STRAP. EXPOSED DUCT MUST HAVE ALL THREAD B 1,779 SF 12 OCC THE ISSUANCE OF. PERMIT N
COPY AND ONE COPY WILL BE RETURNED TO THE CONTRACTOR.SUBMITTALS MAY BE DELIVERED IN PDF 2. DOORS AND FRAMES: HANGERS AND FULL DIAMETER STRAP UP TO 18"0. LARGER THAN 18"MUST HAVE SADDLE TYPE CLAMP.
FORMAT FOR REVIEW. (503)624-6300 (PHONE) BASED ON CONSThOCTION 00
a. NEW HOLLOW METAL-PRIME,SAND,AND FINISH WITH TWO COATS OF SEMI-GLOSS OIL.SPRAY OR e. BRANCH DUCTS SHALL BE PLUMB AND SQUARE(NO OCTOPUS). TEES SHALL BE MAXIMUM OF 45 O
23.THE DESIGN OF FIRE PROTECTION SYSTEMS IS THE RESPONSIBILITY OF THE FIRE PROTECTION SYSTEMS ROLLED APPLICATION. DEGREES. (503)624-7755(FAX) NUMBER OF EXITS REQUIRED DOCUMENTS ANEZ THER U
CONTRACTOR.ALL FIRE PROTECTION SYSTEMS SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER b. EXISTING HOLLOW METAL-SAND,FILL IMPERFECTIONS WITH RONDO,SAND AND PRIME PATCHES WITH I. EACH BRANCH DUCT TO HAVE BALANCE DAMPER IN Y BRANCH. B 1 EXITS DATA SHALL NOT F "EVENT a
INTERFACE WITH EXISTING BUILDING SYSTEMS AND WITH ARCHITECT. ALL SPRINKLER HEADS SHALL BE g. ALL DISTRIBUTION DUCT WORK TO BE INSTALLED MIN.24'ABOVE FINISH CEILING.
LICENSED BY THE APPROPRIATE JURISDICTION FOR THE DESIGN OF THIS TYPE SYSTEM. COORDINATE ALKYD PRIMER,AND FINISH WITH SEMI-GLOSS OIL ENAMEL.SPRAY OR ROLLED APPLICATION BLDG.#: ppCO82(Bldg. B) THE CODE OFFICI,, -FROM
N
CENTERED IN CEILING TILE(OR 2 x 2 MODULE OF A SECOND LOOK II TYPE OF CEILING TILE WHERE c. WOOD-PRIME WITH ALKYD OIL UNDER-COATER,SAND,FILL ALL FASTENING HOLES WITH PAINTER'S 10.FLEX DUCT WILL BE NO LONGER THAN 6'FROM RIGID DUCT DOWN TO DIFFUSER. REQUIRING THE CO' RECTION
-- ----- --- --APPLICABLE). LOCATION OF THOSE IN-GYPSUM BOARD.CEILINGS SHALL-BE-PRE-APPROVED IN WRITING-BY .____.PUTTY,CAULKALL CRACKS.LN-CASINGS ANDBETWEEN JAMBSAND WALLS USING DARLATEX CAULK, ___ _ __.,_ -..__ _ _ _._.__ ___ _.__- --___- . _._, ___ ___ CONST.TYPE.: II-B _OF EflflOflS.-O.SS � 105.4 -.
THE ARCHITECT PRIOR TO INSTALLATION.SUBMITTALS MAY BE DELIVERED IN PDF FORMAT FOR REVIEW. AND FINISH WITH SATIN OIL ENAMEL. 11.DIFFUSERS: - "'---"- -_"- -" -'-- --- --
24.COORDINATE ALL CONSTRUCTION SEQUENCING WITH PACTRUST AND SCHEDULE ALL SERVICE d. WOOD-STAIN,SEAL AS REQUIRED,AND VARNISH WITH SATIN VARNISH. a. SUSPENDED CEILING SYSTEM(T-BAR)-PERFORATED FACE ADJUSTABLE CURVED BLADES-DESIGN THIS BUILDING HOUSES VARIOUS TENANTS INCLUDING THIS TENANT. THE EXISTING
INTERRUPTIONS OUTSIDE NORMAL BUSINESS HOURS TO MINIMIZE INCONVENIENCE TO CURRENT TENANTS. TITUS PCS SUPPLY AND TITUS PAR RETURN OR APPROVED EQUAL.
3. CEILINGS: BUILDING IS A THREE(4)STORY BUILDING OF 87,890 SF AND IS FULLY SPRINKLERED.
08 10 00 DOORS AND WINDOWS b. GYPSUM BOARD CEILING;SUPPLY-CURVED BLADE W/OBD DESIGN TITUS 250;RETURN-BAR TYPE-
a. EXISTING GYP BOARD/PLASTER-SAND,SPACKLE ALL IMPERFECTIONS,SPOT PRIME AND FINISH TO DESIGN TINS 350;EXHAUST-METAL OR ALUMINUM-1/2"x 1/2"EGG CRATE DESIGN TITUS 50F. THERE IS FRONTAGE ON ALL FOUR SIDES OF AT LEAST 60 FEET. EACH FLOOR IS LESS
1. APPROVED DOOR,FRAME,AND HARDWARE SUPPLIERS INCLUDE: ACHIEVE UNIFORM COVERAGE WITH MILLER PAINT 6200 OR 4480. THEN 23,000 SF ALLOWING FOR NON SEPARATED USES.
a. BAXTER AND FLAMING. (503)225-0486 b. NEW GYP BOARD/PLASTER -PRIME WITH SUPER SEAL AND FINISH TO ACHIEVE UNIFORM COVERAGE c. ALL SUPPLY REGISTERS TO HAVE MANUAL VOLUME DAMPERS LOCATED IN DUCT AT OR NEAR CLOSEST
WITH MILLER PAINT 6200 OR 4480WYE BRANCH.
.
b. 0&D DOOR (503)205-5533 d. CLEAN OR REPLACE ALL SUPPLY AND RETURN AIR GRILLS AND THEIR HOUSINGS AT PROJECT ALLOWABLE AREA
c. BENSON INDUSTRIES (503)907-2200 4. GENERAL NOTES: COMPLETION.
d. GRANT SUPPLY (360)887-0647 a. KEEP ALL HARDWARE,HINGES,AND DOOR KNOBS CLEAN OF ALL PAINT SPLATTERS,DRIPS,OR ROLLER 12.THERMOSTAT: ALL EXISTING MERCURY TYPE THERMOSTATS TO BE REPLACED. NEW THERMOSTATS TO BE B 23,000 SF BASE AREA
SPRAY. HONEYWELL COMMERCIAL (V N EL TB8220U1003 W�(E(� Pp$$(g1 69,000 SF 300% INCREASE FOR MULTI STORY
3. DOOR AND RELITE FRAMES SHALL BE ALPHA ALUMINUM PRODUCTS, INC.(AAP).SUBMITTAL REQUIRED PRIOR b. ALL SURFACES TO BE SANDED BETWEEN COATS,PRIOR TO INSTALLATION OF NEXT COAT. APPROVED SUBSTITUTE: 1'QTAI-LINE S1Ti TIII7EG`61[fMERd 'PHOSTAT MODEL NO.P9743�Q`-7 6AY
TO ORDERING MATERIAL.NEW FRAMES TO BE FACTORY FINISH CUSTOM COLOR. PROGRAMMABLE WITH LOCKOUT FUNCTI -nu i u cainrvcit ER ONLY. MOUNT"A7 ADA HEIGHT(MAY 46,000 SF 200% INCREASE FOR SPRINKLERS
c. DURING PROGRESS OF WORK,KEEP JOB SITE CLEAN OF ALL PAINT MATERIALS,RUBBISH,CANS,AND REQUIRE CHANGING HEIGHT AT"REPLACEMENT"LOCATIONS CONTRACTOR SHALL PROGRAM :7,250 SF 75% INCREASE FOR FRONTAGE
4. FIELD VERIFY EXISTING DOOR,FRAME AND HARDWARE FINISH PRIOR TO ORDERING. ALL NEW DOORS, RAGS AT THE END OF EACH DAY. )'
FRAMES AND HARDWARE TO MATCH EXISTING BUILDING STANDARDS. THERMOSTATS AND BALANCE SYSTEM. 1.55,250 SF TOTAL ALLOWABLE AREA
5. ALL INTERIOR DOORS SHALL BE SOLID CORE WOOD UNLESS NOTED OTHERWISE. d. UPON COMPLETION OF WORK,CLEAN ANY PAINT SPLATTER BY USING PROPER METHODS OF WASHING 13.THERMOSTAT LOCATIONS TO BE REVIEWED BY ARCHITECT PRIOR TO INSTALLATION.
AND SCRAPING,USING CARE NOT TO SCRATCH OR DAMAGE FINISHED SURFACES.
6. DOOR HARDWARE SHALL BE SCHLAGE AL SATURN OR D RHODES SERIES U.N.O. e. PROTECT WORK OF OTHER TRADES, 14.HVAC TESTING. COD- SUMMARY
7. ALL DOOR HARDWARE SHALL BE INSTALLED WITH A 2 3/4"BACKSET. a. CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES,COMPONENTS,
f. PROVIDE"WET PAINT"SIGNS AS REQUIRED TO PROTECT NEWLY PAINTED FINISHES. EQUIPMENT AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH ALL CONSTRUCTION WORK SHALL BE DONE IN COMPLIANCE WITH STATE AND LOCAL
8. DOOR FINISH SUBMITTAL:CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR DOOR FRAMES,DOOR APPROVED PLANS AND SPECIFICATIONS. CODE REQUIREMENTS THAT APPLY, INCLUDING BUT NOT LIMITED TO:
HARDWARE AND DOORS AS WELL AS A CONTROL SAMPLE OF THE FINISHED DOOR SKIN Wl STAIN AND FINISH 10 00 00 SPECIALTIES
OSSC
b. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN • 2019 OREGON STRUCTURAL SPECIALTY CODE(
APPLIED(IF NEW DOORS ARE BEING PROVIDED). BEFORE FINISHING OF DOORS IS COMMENCED ARCHITECT 10 28 13 BREAK COUNTER )
SHALL APPROVE CONTROL SAMPLE. FINISHED PRODUCT IS SUBJECT TO REJECTION BY ARCHITECT IF THIS ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. • 2019 OREGON MECHANICAL SPECIALTY CODE(OMSC)
PROCESS IS NOT FULLY ADHERED TO AND FIELD PRODUCT DOES NOT MATCH THE APPROVED CONTROL 1. PAPER TOWEL DISPENSERS,SURFACE MOUNTED(KITCHENBREAK ROOM)BOBRICK B-262 c. A COMPLETE COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND • 2017 OREGON PLUMBING SPECIALTY CODE(OPSC)
SAMPLE. 10 44 16 FIRE EXTINGUISHERS FILED WITH PACTRUST. • 2017 OREGON ELECTRICAL SPECIALTY CODE(OESC) am
9. ALL INTERIOR GLAZING SHALL BE TEMPERED. 1. FIRE EXTINGUISHER 2A10 BC (WALL MOUNTED OR IN SEMI RECESSED CABINET AS INDICATED ON PLAN) 15.PROJECT CLOSE OUT DOCUMENTS REQUIRED: • 2019 OREGON FIRE CODE(OFC)
10.IN ALPHA ALUMINUM CLEAR ANODIZED PRODUCTS USE GRAY SEALS.MATCH IF EXISTING.ALL OTHER 2. FIRE EXTINGUISHER CABINET: JL INDUSTRIES ACADEMY SERIES MODEL#C1027V10. a. AutoCAD FILE SHOWING AS-BUILT INFORMATION. • ASCE-7-10
CONDITIONS USE BLACK. 12 00 00 FURNISHINGS b. ELECTRONIC PDF FILE OF THE AutoCAD FILE ABOVE. a ICC/ANSI Al 17.1-2017
09 00 00 FINISHES 1. PROVIDE ROLLER BLINDS AT ALL EXTERIOR WINDOWS. c. HARD COPY OF AutoCAD FILE ABOVE. 2019 OREGON ENERGY EFFICIENCY SPECIALTY CODE
GENERAL a. MARIAK CONTRACT CHAIN OPERATED CLUTCH ROLLER SHADES d. OPERATIONS MANUALS FOR ALL EQUIPMENT,INCLUDING TSTATS.
1. REMOVE ALL EXISTING VCT,SHEET VINYL,ETC.IN AREAS WHERE NEW FLOOR COVERING IS SPECIFIED PRIOR b. NO HEAD BOX U.N.O. e. COLORED ZONE MAP WITH THERMOSTAT LOCATIONS INDICATED.
TO INSTALLATION OF NEW FLOORING. PROJECT LOCATION
L 2. CLEAN,SEAL AND WAX ALL RESILIENT FLOORS PER MANUFACTURERS SPECIFICATIONS.EXCLUDES LVT AND c. FABRIC-MARIAK ECONOSCREEN-3%COLOR-903 GRAY/BLACK U.N.O. 26 00 00 ELECTRICAL : DESIGN/BUILD I 1
SOME VCT APPLICATIONS.VERIFY WITH ARCHITECT PRIOR TO APPLYING WAX COATINGS. 2. INSTALL BUILDING STANDARD ADDRESS AND/OR SUITE NUMBER LABELS TO ALL EXTERIOR DOORS. GENERAL - S.W. HAMPTON STREET
3. SUBMIT ONE SAMPLE OR DRAW DOWN NO LARGER THEN 11 X 17 FOR THE FOLLOWING: 12 23 16 CABINET SPECIFICATIONS 1. ALL ELECTRICAL FEEDS TO OUTLETS,SWITCHES,ETC.MUST BE VERTICAL DROPS FROM ABOVE EXCEPT FOR
a. FLOOR COVERINGS,BASE AND TRANSITION STRIPS 1. ALL CABINETRY TO BE INSTALLED OVER FINISH FLOOR AT ALL RESILIENT FLOORING LOCATIONS. HORIZONTAL RUNS UNDER WINDOWS AND RECEPTACLES ON THE SAME STUD. f , Q
b. PLASTIC LAMINATES 2. ALL ELECTRICAL FEEDS TO OUTLETS AND DATA BELOW WINDOW SILLS TO BE ROUTED THROUGH BUILDING _ `J W
2. AWI CUSTOM GRADE STANDARDS FOR CASEWORK AND COUNTER TOPS U.N.O SHELL WALLS. DO NOT FEED FROM PERPENDICULAR INTERIOR PARTITIONS. v i I I I I U I I I I I I I I I I I 1' z Z O
c. ALL NATURAL WOOD(INCLUDING DOORS AND CASEWORK) 3. HIGH PRESSURE LAMINATE(P-LAM HPL)ALL EXTERIOR SURFACES,INCLUDING 4"TOE KICK. EDGE BANDING > O
d. PAINT (MATCHING PV„ACCEPTABLE),FIN ENDS,DOORS,AND LIGHT VALENCE ETC. UPPER CABINET BOTTOMS 3. ALL NEW ELECTRICAL DEVICES TO BE WHITE.NYLON COVER PLATES NOT ALLOWED. LLI
U
OPTIONAL HPL FINISH,STANDARD MELAMINE FINISH. OPEN CABINETS OPTIONAL HPL FINISH,STANDARD 4. REPLACE ALL NON-WHITE EXISTING ELECTRICAL DEVICES TO WHITE.NYLON COVER PLATES NOT ALLOWED.
e. TILE,MARBLE,GRANITE,STONE,GROUT AND SCHLUTER TRIMS MELAMINE FINISH. - V
5. PROVIDE LABELS AT EACH ELECTRICAL RECEPTACLE IDENTIFYING CORRESPONDING PANEL AND BREAKER. - N
f. TOILET PARTITIONS 4. TOE KICK PLYWOOD 4"H WITH P-LAM COVER
5. FINISH FLOORING TO EXTEND UNDER ALL NEW CASEWORK. 5. DOORS AND DRAWER FRONTS PLASTIC LAMINATE OVER 11116"PARTICLE BOARD WITH MATCHING P-LAM OR 6. PROVIDE TYPEWRITTEN UPDATED SCHEDULE AT PANEL TO IDENTIFY CIRCUIT BREAKERS.
IO�
7. VERIFY ELECTRICAL METER AND TAG METER WITH THE TENANT'S ADDRESS OR SUITE NUMBER. METER - 7` a
6. PROVIDE A TRANSITION STRIP WHERE EVER TWO DIFFERENT FLOOR MATERIALS MEET PER TRANSITION PVC EDGES. IDENTIFICATION NUMBER AND TENANT ADDRESS INFORMATION SHALL BE GIVEN TO PACTRUST PRIOR TO - N I O
STRIP DETAILS. 6. MELAMINE(LOW PRESSURE LAMINATE/LPL)ALL INTERIOR AREAS,DRAWER PARTS,SHELVING ETC. TENANTS MOVE-IN. ai �_ d. =
7. PROVIDE SCHLUTER METAL TRIM AT ALL EXPOSED EDGES OF TILE(EXCEPT AT BULLNOSED EDGE) 7. FLUSH OVERLAY/FRAMELESS SME CONSTRUCTION. 8. ELECTRICAL CONTRACTOR TO PROVIDE EMERGENCY LIGHTING IN EXIT PATH SHOWN ON PLAN EQUAL TO = � 00
8. CONTRACTOR TO PROVIDE 10%ATTIC STOCK FOR ALL FLOOR TILE PRODUCTS UNLESS DIRECTED 8. THERE SHOULD BE 1/8"OR LESS GAP TOLERANCE BETWEEN DOORS AND DRAWERS. 1-FOOT CANDLE. _ \ _ Q U >
OTHERWISE. 9. HINGES-BLUN#75M3580, 110 DEG.SELF CLOSING CLIP ON OR EQUAL). 9. EXIT LIGHTS:LITHONIA EDGR-G-EL RECESSED MOUNT,GREEN LETTERS.(CLASS A BUILDINGS) = A _I _ m L) > Q
09 2100 GYPSUM BOARD ( ( ) 11.FOR FLOOR POWER AND DATA ACCESS _ "��_ - LL, m
10.DRAWER SLIDES-BLUM #230M SERIES EXTENSION OR EQUAL)75 LBS.MIN.FOR STANDARD DRAWERS. I I I I!I I [fill I � O
GENERAL ACCURIDE#4032(OR EQUAL)HD/FULL EXT 150 LBS.MIN.FOR HD AND FILE DRAWERS. a. AT RAISED SLABS:USE WIREMOLD RC7 FLUSH POKE-THRU SERIES OR EQUAL. __ () D_'
1. ALL GYPSUM BOARD WALLS: ONE LAYER 5/8"TYPE X GYPSUM WALLBOARD,EITHER AT RIGHT ANGLES OR 11.PULLS-96 MM C-TO-C WIRE PULLS. FINISH TO MATCH DOOR HARDWARE. b. AT SLAB ON GRADE:USE WIREMOLD RFB4E BOX WITH 6CTC2 COVER AT CONFERENCE ROOMS _ I d N d
PARALLEL TO FRAMING ON EACH SIDE OF METAL STUDS SPACED AT 24"O.C. FASTEN WITH 1"TYPE S AND 6CFFTC COVER AT FURNITURE FEEDS.PROVIDE 1"CONDUIT FOR POWER AND 2"CONDUIT FOR - _
DRYWALL SCREWS 8"O.C.TO VERTICAL EDGES AND 12"O.C.TO TOP AND BOTTOM RUNNERS AND 12.GENERAL CONTRACTOR TO PROVIDE CABINET MAKER WITH SINK TEMPLATE(SPEC SHEETS)FOR EACH SINK. DATA. =m \FF77M-777TV
INTERMEDIATE STUDS. STAGGER ALL VERTICAL AND HORIZONTAL JOINTS 24"O.C.(OR ONE STUD SPACING), SINK CUTOUT SHALL BE DONE IN SHOP WHEN FEASIBLE AND BEFORE BACK SPLASH IS INSTALLED IN ALL - 2/12
DATE. /21
EACH SIDE AND OPPOSITE SIDES. CASES TO ALLOW CUT OUT TO BE POSITIONED PROPERLY. ALL RAW EDGES OF CUT OUT AND BACK SPLASH 12.LOW VOLTAGE SYSTEMS(TELECOMMUNICATION AND DATA)BY FUTURE TENANT. L L
2. ALL OFFICE GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND TWO FINISH COATS WITH SANDING BETWEEN
TO BE SEALEC. MINIMIZE COUNTERTOP BUILDUPS AT FRONT AND BACK OF SINK CUTOUT TO 13.LIGHTING ENERGY MANAGEMENT IS REQUIRED IN ALL BUILDINGS. - PERMIT / CONST
ACCOMMODATE PLUMBERS SINK CLAMPS CLEARANCE.
FINISH COATS(LEVEL 4 FINISH). PAINT AS INDICATED. 13.KITCHENBREAK ROOM CABINETS-BASE CABINET WITH P-LAM TOP ON PLYWOOD DECKING AND 4"BACK 14.OCCUPANCY CONTROL DEVICES SHALL BE LEVITON OR WATT STOP. _
3. ALL OTHER GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND ONE FINISH COAT WITH SANDING AFTER FINISH SPLASH. ALL CABINETS TO HAVE DOORS AND DRAWERS,U.N.O. UPPERS 12"D X 36"H-ATTACH TO WALL 15.TEST ALL LIGHTING CONTROL SYSTEMS TO ENSURE THAT CONTROL DEVICES,COMPONENTS,EQUIPMENT REVISION
COAT(LEVEL 3 FINISH). PAINT AS INDICATED. WITH FRENCH CLEAT,COUNTER AND COUNTERTOPS 24"DEEP. MICROWAVE SHELF 18"D WITH 3"RADIUS AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND r
41 .
. IN FINISHED SPACES FURR-OUT BUILDING COLUMNS AND EXTERIOR WALLS WITH 5/8"GYPSUM BOARD OVER OUTSIDE CORNERS. P-LAM AT TOE/BASE. ALL SHELVES ADJUSTABLE.METAL STUDS. BASE,2 AT UPPERS). IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS.PROVIDE HOLES AND POSTS(1 AT SPECIFICATIONS. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE
5. PROVIDE ACOUSTIC GASKETS WHERE WALL INTERSECTS STOREFRONT.QUIETJOINT SHH WHERE WALL 2100 00 FIRE SUPPRESSION : DESIGN/BUILD 16.REMOVE ALL UNUSED DATA AND POWER BOXES AND INFILL WITH GYP BOARD. EXCEPTION-UNUSED DATA - Iv
MEETS MULLION AND EMSEAL WHERE WALL MEETS GLAZING.COLOR SELECTED BY ARCHITECT. BOXES UNDER WINDOW SILLS TO REMAIN. ALL BLANK COVER PLATES TO FINISH SPECIFICATIONS. LOCATION MAP
1. ADJUST EXIST•.NG SPRINKLERS THROUGHOUT SPACE AS REQUIRED BY CODE. SPRINKLER HEADS SHALL BE � 2.
6. AT ALL EXISTING WALLS, REMOVE ALL NAILS,SCREWS,FASTENERS,ETC.LEFT BY PREVIOUS TENANT AND CENTERED IN'2 X 2 CEILING TILE.LAYOUT OF SPRINKLERS BY CONTRACTOR. SPRINKLER LAYOUT IN ALL HARD 17.REMOVE ALL UNUSED LOW VOLTAGE WIRING(TELEPHONE AND DATA)FROM THE RECEPTACLE TO THE 0A- NOT TO SCALE
PATCH HOLES READY FOR PAINT. CEILING AREAS(GYPSUM BOARD/PLASTER)TO BE REVIEWED AND APPROVED BY ARCHITECT PRIOR TO DISTRIBUTION BOARD.LEAVE PULL STRINGS FROM THE BOX TO THE SPACE ABOVE THE CEILING. A SECTION
7. REPAIR GYPSUM BOARD AT REMOVED ELECTRICAL RECEPTACLES OR DATA BOXES AND FINISH READY FOR INSTALLATION. OF THE EXISTING LOW VOLTAGE WIRE MAY BE LEFT IN LIEU OF A PULL STRING. 3'
PAINT. 22 00 00 PLUMBING : DESIGN/BUILD
OFFICE LIGHTING __ _ _ ---_ 4
8. UPON REMOVAL OF WALL BASE,REMOVE RESIDUAL ADHESIVE AND PREP WALL TO PAINT READY CONDITION. GENERAL REQUIREMENTS 1. OFFICE LIGHT FIXTURES: LITHONIA LED FIXTURE.2BLT2 40L ADP MVOLT GZ10 LP835. -----------
WALL CONSTRUCTION MATERIALS 1. CONTRACTOR TO SUBMIT LAYOUT ON ELEVATIONS AND PLANS PROVIDED FOR ALL SHUT OFF VALVES,CLEAN 2. RECESSED LED DOWN LIGHT: LITHONIA LDN6 35/10 L06 AR LD MVOLT TRW(IP55 LENS) ------- ----------------- 5.
OUTS,ACCESS DOORS,AND FLOOR DRAINS TO THE ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. 3. OFFICE EGRESS LIGHTING:ISOLITE MINI GENIE SERIES LED VERSION LMIGN NM SQ-CEILING AND WALL
1. PROVIDE STUDS,TRACKS, BRACING,FASTENING AND OTHER ACCESSORIES NECESSARY FOR COMPLETE MOUNT. SEE PLAN FOR EGRESS PATH.USE OF ISOLITE INVERTER AS ALTERNATE TO BATTERY IS 6"
INSTALLATION. 2. PLUMBING CONTRACTOR TO PROVIDE AND INSTALL(1)MASTER SHUT OFF VALVE FOR EACH SET OF ACCEPTABLE.
2. FRAMING MEMBERS SHALL HAVE THE STRUCTURAL PROPERTIES INDICATED ON PLANS WHERE PHYSICAL RESTROOMS. LOCATE VALVE BEHIND HANDICAP WATER CLOSET IN MEN'S TOILET ROOM. - _ 7
STRUCTURAL PROPERTIES ARE NOT INDICATED,THEY SHALL BE AS NECESSARY TO WITHSTAND ALL IMPOSED 3. ALL DOMESTIC WATER PIPING TO BE TYPE L COPPER-NO EXCEPTIONS. ALL EXPOSED PIPING TO BE 4. LIGHT SWITCHES:ACUITY CONTROLS PRE SET ALL PRIVATE OFFICE AND CONFERENCE ROOM SWITCHES TO
LIVE LOADS. DESIGN FRAMING IN ACCORDANCE WITH AISI SG-673. INSULATED. 'VACANCY"AND TO TURN ON AT LAST DIM LEVEL.SET TIME-OUT TO MAXIMUM. 8.
3. COLD-FORMED FRAMING SHALL BE GALVANIZED METAL CONFORMING TO ASTM A446/A 446 M GRADE A(33000 4. WATER HEATER(ELECTRIC)30 GAL AND LARGER 277V LESS THAN 30 GAL 120V. PROVIDE HUB DRAIN AT a. STANDARD WALL SWITCH WITH OCCUPANCY SENSOR-USE WSD
PSI)G60. LOCATION FOR BLOW OFF. b. WALL SWITCH WITH OCCUPANCY SENSOR AND DIMMING-USE WSXD -
4. PROVIDE THE LISTED GYPSUM BOARD PRODUCTS BY U.S.GYPSUM,GEORGIA PACIFIC,NATIONAL GYPSUM OR 5. POINT OF DEMAND WATER HEATER-BOSCH POWER STREAM PRO-MODEL RP2P 277V/30A. ADJUST WATER c. WALL SWITCH WITH DIMMING AND CEILING MOUNTED OCCUPANCY SENSOR-USE SPOD X� DRAWN BY:
AN APPROVED EQUAL. FLOW SETTING TO PROVIDE A HEATING RANGE OF 105 TO 120 DEGREES. 28 30 00 ELECTRONIC DETECTION AND ALARM -
5. STANDARD GYPSUM BOARD SHALL BE TYPE'X',518"THICK WITH TAPERED EDGES CONFORMING TO ASTM 6. FLOOR DRAINS SHALL BE INSTALLED IN TOILET ROOMS CONTAINING 2 OR MORE WATER CLOSETS OR 2 OR - R.M.T.
, C-38. MORE WATER CLOSETS AND URINALS IN COMBINATION. THE FLOOR SHALL SLOPE TOWARD THE FLOOR
GENERAL
6. WATER RESISTANT GYPSUM BOARD SHALL BE 5/6"THICK WITH TAPERED EDGES. CONFORMING TO ASTM DRAIN. 1. FOR HORN/STROBE DEVICES USE"SYSTEM SENSOR'SPECTRALERT ADVANCE DEVICES,OR APPROVED
C-630. 7. FLOOR DRAINS TO BE INSTALLED WITH PRIMER VALVE WITH ISOLATION VALVE. NO ATMOSPHERIC EQUAL. ' ' --
7. AT TOILET ROOMS USE 5/8"USG FIBERROCK BRAND AQUATOUGH INTERIOR PANEL FROM FLOOR PRIMERS. DRAINS TO BE PRIMED FROM TOILET FIXTURES UNLESS OTHERWISE APPROVED BY _ 2. ALL FIRE ALARM WORK BY VENDERS LISTED BELOW:
TO 48"A.F.F.ON WALLS BEHIND OR ADJACENT TO PLUMBING FIXTURES. NO SUBSTITUTES. PACTRUST. PROVIDE A MIN. 12"x 12"ACCESS DOOR. a. BUILDING REMODEL:POINT MONITOR.
(EXCEPTION:EXCEPTION AT LOCATIONS TO RECEIVE PLASTIC LAMINATE OR TILE WAINSCOT.) PLUMBING-BREAK ROOM FIXTURES - ----------- ------ - -------------------------------
b. FIRE PANEL REPLACEMENT:POINT MONITOR. '
8. AT TILE WAINSCOT LOCATIONS INSTALL CEMENT BACKER BOARD 1/2"THICK WITH SQUARE,REINFORCED, 1. BREAK ROOM SINK ELKAY ELUHAD211555(UNDER COUNTER MOUNT). ----------
SMOOTH EDGES. PROVIDE DUROCK BRAND CEMENT BOARD OR APPROVED EQUAL. c. SERVICE CALLS:POINT MONITOR.
2. KITCHEN FAUCET-AMERICAN STANDARD COLONY SOFT SINGLE CONTROL FAUCET#4175.500. ---"--"
9. INSTALL WATER-RESISTANT GYPSUM BOARD BEHIND WAINSCOT OF FRP,PLASTIC LAMINATE,ETC. d. QUARTERLY TESTING:STANLEY.
3. 1/4"COPPER WATERLINE W/SHUT OFF VALVE FOR COFFEE MAKER AND REFRIGERATOR,SEPARATE LINES IF e. FIRE ALARM MONITORING:STANLEY. AREA OF WORK
10.TRIM ACCESSORIES SHALL COMPLY WITH ASTM C-1047. REQUIRED /�
11.USE GEORGIA PACIFIC DENSGLAS GOLD ON EXTERIOR FACE OF EXTERIOR WALLS AND COAT WITH STO FINISH / L \ BUILDING PLAN
SYSTEM.
A 1 NOT TO SCALE Z
IIIO O I WORK TO INCLUDE
U u I � u O O u I �J • NEW PAINT THROUGHOUT DETAIL GENERAL NOTES:
• ALL NEW AND EXISTING ELECTRICAL FIXTURES TO BE WHITE 1. FOR WALLS UP TO 14'-0"TALL, USE 362S125.30 MTL. STUDS @ 24"O.C. UNLESS C:)J /
• #3082
NEW ROLLER BLINDS AT EXTERIOR WINDOWS
CALLED OUT OTHERWISE IN DETAIL. USE 362T125-30 MTL. TRACK.
is tr NEW PLANK STYLE CARPET AS SHOWN MARTIN W.HANSON
-_ 2. FOR WALLS OVER 14'-0"TALL, USE 6005125-33 MTL. STUDS 16" O.C. UNLESS n
�I • NEW LVT FLOORING AT BREAK ROOM e°
___ '�-�' ___ • INSTALL SOUND CURTAIN OVER SOUTH DEMISING WALL
CALLED OUT OTHERWISE IN DETAIL. USE 600T125-33 MTL. TRACK.
T�I i -�_ i ` VAI�( N �i ► • BREAK COUNTER 3. ALL WALLS: ATTACH BOTTOM TRACK TO FLOOR WITH POWDER DRIVEN (f)�CLACKAM S,OREGON
4s.REF. o o II I -.r •• REPLACE COUNTER WITH SOLID SURFACE COUNTER TOP AND BACK SPLASH ANCHI p7 2q p�C
d 4. I ALLS WITH'ACOUSTIC INSULATION, SET BOTTOM TRACK IN BED OF SEALANT.
k_ I •• RE-SURFACE BREAK CABINET
-L}i_- !I I I e BREAK IT/STOR/COPY CONFERENCE ** NEW BRUSHED CHROME HANDLES AT CASEWORK OF 5. FOR WALL FINISHES, FLOOR FINISHES AND WALL BASE TYPE, REFER TO r
k"" ^� to6 tos oe • DOORS AND RELITES PROJECT FINISH SCHEDULE.
�(T4}1,P _ •• NEW DOORS THROUGHOUT
'-�I I I I 4S It 05 �
- s — POWDER DRIVEN ANCHORS PROJECT #21100
--_ 3•-0• mz: •• NEW DOOR WINDOW FRAMES
� i I I
IJ --- II! J CEILINGS
66•MICRO
II ` L_ J II � �
II III \ 81 `
L_ �___ - •• CLEAN/TUNE REPLACGRID AS E
STRUCTURAL SUPPORTING CALCS:
Fea; - ;iof; •• CLEAN/REPLACE HVAC GRILLS FOR AS NEW LOOK
-- - •• NEW LED BLT LIGHTING THROUGHOUT 1. POWERS 0.300 HEAD(3/4" EMBED)0.145 SHANK DIAMETER
•• NEW DUNE STYLE CEILING TILES THROUGHOUT ALLOWABLE SHEAR=70 LBS
�- OPEN OFFICE •• NEW EXIT SIGNS AS NEEDED TO MATCH SPECIFICATIONSU
2. 12'-0" TALL WALL WITH CODE REQUIRED 5 PSF MINIMUM LATERAL(WIND)
LOAD SHEAR=5 PSF " 12'-0"/2 =30 PLF
------ ------------ -= 3. ANCHORS AT 16"O/C
I SHEAR=30 PLF • 16"/ 12"=40 LBS
1„ 324" 168" 324" 4. UNITY CHECK L
=tt --', 40 LBS/70 LBS =0.57< 1.0 OK
RECEPTION/SHOWROOM ► PL i
5. ANCHORS AT 24"O/C
' too SHEAR=30PLF •24"/ 12"=60 LBS
II ----- -- OFFICE OFFICE ' _ _'_ADJ.UHELF_�_ 6. UNITY CHECK O
60 Ibs/70 Ibs= 0.86 < 1.0 OK O 0 OM
fo
! MICRO SHELF AT C
1
18"DEEP WITH 2" __ �__ -__ OA-2
GENERAL NOTES C6
LL
► RADIOUS CORNERS
_ I _ OPEN BACK \ \ PL-1 SCALE 1° = V-0" = Q N
1— PL-1 ALL SURFACES
O rn
I I _ I PROVIDE PAPER �
' TOWEL DISPENSER ow O
323„ 33.1 163' 323„ LLI O to
4 LO
8 4 �, 36" ch0Mr
/ ACOUSTICAL BLANKET ABOVE GRID. KINETICS 2� Z v v
_ _ _ _ _ /// -• KNM 100RB. TAPE WITH 3M 3015VP TAPE. SEAL (q g N N
II TBACKSPLAS _) CEILING TILES WHERE INDICATED O H co
LO— — — I 20 GA 3 5/8" METAL STUD BRACING TO ROOF C m 0 o co
PL-1 �-- ---al STRUCTURE AT 10'-0"OC WHERE REQUIRED c d vLO
DEMO PLAN z EPARTITION AND POWER PLAN z , 4� , — ADrsINK \ j m
A-2 SCALE 1/8" = V-0" A-2 SCALE 1/8" = V-0" �DJ SHELI --- — \ / a v� SUSPENDED CEILING
---------�
m
/ \/ PL-1 RACO STYLE RECESSED REVEAL HEADER. m
P-LAM BASE CONCEPT WALLS#1-487RDT
N
MTL. STUDS. 00
5/8"GYP. BD. BOTH SIDES C
CL
5 CABINET ELEVATION z �_ i '_
A_2-SCALE 1/2" = 1'-0" w - - — CENTER LINE OF STUD
- _ -- - - - � - 3-1/2" BATT INSUCTN SOUND ATTENUATION WALLS
-- -- -- - - -------
- vIL—j FINISH MATERIALS
ALL FINISHES MUST BE SUBMITTED TO PACTRUST PRIOR TO INSTALLATION.
CARPET PLANK TILE: BOTTOM TRACK.
CPT-1 MOHAWK GROUP PTR-CARPET PLANK"ART STYLE"METALIC PATH BT431/OB431
I COLOR T.B.D., FLEXLOK CONNECTORS
I ! !
I (NOTE: FOR PRICING OF ALL MOHAWK PRODUCTS CONTACT: FINISH FLOOR
1i BETH GISH(503)704-4168 or STEPHEN DELONG(971)201-0458
LUXURY VINYL TILE
ISI " ' LST MOHAWKGROUP STONE C0135 10 WALL SECTION WITH SOUND INS. / CURTAIN
JT MATUTO PLUS
I II • • i �; r_` • I I�.}Z • COLOR T.B.D. A-2 SCALE 1" = V-0" N
- -- �' \ _ I ` _�R __ J BASE2-FLEXCO 4"FLAT RUBBER BASE,COLOR T.B.D.,AT ALL CARPET AREAS. 2
A
RC FLEXCO 4"COVE RUBBER BASE, COLOR T.B.D.,AT ALL HARD SURFACES. �
PAINT: v
I�-\�1
iE
PT-1 MILLER 110-4-10 ACRO PURE ULTRA-LOW VOC COLOR T.B.D., SATIN LATEX. yE a
4 �J LS �J L� '� LS �U
�- *1 I�III ` �• /� 1 1 I ' �'�
LAMINATE:CAB PULLS 626 SATIN CHROME o / /
IPL-1 FORMICA COLOR T.B.D. ALL FACES
0.
•`
COUNTERTOP OC D URFACP COUNTERS QUARTZ COLOR T.B.D. COUNTER, B.S. AND SELF-EDGE PROVIDE HC SIGNAGE FOR ALL
RfTS
U L , R �N ` / ' NEW AND EXISTING K MEN
DOORS, HARDWARE AND FRAMES � KROY#2835207 BLACK(MEN)
[/ - ,-- - • • >� . � -,, „ • • i KROY#2835209BLACK(WOMEN)
HI r
! ! DOORS SOLID CORE it t
FINISH QUARTER SLICE, AFRICAN MAHOGANY, 70284-A WALNUT STAIN -
MFGR PACIFIC ARCHITECTURAL WOOD PRODUCTS, INC. w "E" ADDITIONAL SWITCH
z
ADDRESS 714 NE 55TH AVENUE, PORTLAND,OR 97213 p GANG LOCATION
CONTACT DENNIS BRYANT PHONE: 4-0024 FA 4 _ _
— � ., -�:,----- �,•��� r, - ,� � c �_ _ ! E:(503)28 X: (503) 0107 28 ¢ � � � w
0d w
HARDWARE SATIN CHROME �'�`— \ Z Z O
WWII
FRAMES CLEAR ANODIZED cow - �- O
Z Z _ LLI
' __jE — CONTRACTOR TO PROVIDE BUILDING STANDARD BLINDS AT ALL EXTERIOR GLASS. _ U d U
— — ry = , — — — — — — ELECTRICAL W t_I¢ z U � �
_ f OUTLETOR w U) N
J-BOX U) 0 U) � Z I�
N TR - 0 mix w � D O1
��z z CO S UCTION LEGEND � o r,�w JIM C) i0 W a z
— _ — — EXISTING TO REMAIN
\ - • 0 00
UND
RCUT DOOR
_ - ------- f \ QQ 0 OS Aof
REQUIRE- EXISTING TO BE REMOVED D TO CLEAR
I >
FLOOR FINISH J p
Q
fn
2 2 '2 NEW WALL WITH SOUND INSULATION 11 MOUNTING HEIGHTS - ¢ N
DEMO CEILING PLAN REFLECTED CEILING PLAN
DUPLEX RECEPTACLE U O
OA-2 0
SCALE 1/8" = V- " OA-2SCALE 1/8" = V-0" 0
FOURPLEX RECEPTACLE A-2 SCALE 1/2 = 1'-0" DATE: 2/12/21
o#�) DEDICATED OUTLET PERMIT / CONST
6v EXISTING ELECTRICAL TO REMAIN REVISION
=�'LA FLOOR MONUMENT W/SERVICES SHOWN
SPECIAL OUTLET 1•
44 TEL/DATA MUD RING WITH PULL STRING 2.
DOOR SCHEDULE a ELECTRICAL PANEL
3.
DOOR DATA I FRAME DATA 1' IRE RATING I HARDWARE I REMARKS MARK 0 POWER J-BOX 4.
MARK DOOR SIZE THK CORE VENEER FINISH HAND I MANUF. FINISH DEPTH I ACTION I MANUFACTURER FINISH I FUNCTION 5.
102 3'-0"x 9'-0" 1 3/4" SC QS AFRICAN MAHOGONY 60101 LIGHT Left I ALPHA ANOD. ALUMN 47/8" -- LEVER LATCH SCHLAGE 626 SATIN CHROME I ALX10S 13 X 9 SIDELITE 1102 ® FLUSH MOUNT FLOOR MONUMENT W/POWER AND DATA
103 T-0"x 9'-0" 1 3/4" SC QS AFRICAN MAHOGONY 60101 LIGHT Right ALPHA ANDD. ALUMN 4 7/8" 1 LEVER LATCH I SCHLAGE 626 SATIN CHROME ALX10S 3 X 9 SIDELITE 103 2 X 2 LED BLT CEILING FIXTURE 6.
104 T-0"x 9'-0" 13/4" SC QS AFRICAN MAHOGONY 60101 LIGHT Left ALPHA ANDD. ALUMN 47/8" 1 LEVER LATCH I SCHLAGE 626 SATIN CHROME ALX10S 3 X 9 SIDELITE 104 RECESSED INCANDESCENT LIGHT ON RHEOSTAT(TYP.) 7.
1105 T-0" x 9'-0" 1 3/4" SC QS AFRICAN MAHOGONY 60101 LIGHT Left ALPHA ANOD. ALUMN 4 7l8" LEVER/LOCK SCHLAGE 626 SATIN CHROME ALX53PD 105 SUPPLY
® RETURN DI $•
DUCT
FINISH SCHEDULE OT THERMOSTAT DRAWN BY:
RM# NAME FLOOR BASE
(WALLS CEILINGS REMARKS RM# ® EXHAUSTFAN R.M.T.
NORTH JEAST I SOUTH I WEST MATERIAL HEIGHT TILE SPRINKLER HEAD
1 100 1 RECEPTION/SHOWROOM CPT-1 4" RF E-WW-PGWB E-PGWB PGWB PGWB E-SAT 9'-0" 100
101 OPEN OFFICE CPT-1 4" RF PGWB PGWB PGWB PGWB E-SAT 9'-0" -- 101 8 EXIT SIGN(LED RED)
102 CONFERENCE CPT-1 4" RF E-PGWB PGWB PGWB E-PGWB E-SAT 9'-0" -- 102 ply HORN/STROBE FIRE ALARM
103 1 OFFICE CPT-1 4" RF PGWB E-PGWB PGWB E-WW-PGWB E-SAT 9'-0" 103 SCHLUTER
A� 2
104 IOFFfCE CPT-1 4" RF IPGWB E-PGWB PGWB E-WW-PGWB E-SAT 9'-0" 104 SCHIENEAE30
1105 IT/STOR/COPY LVT 4" RC E-PGWB E-PGWB E-PGWB PGWB E-SAT 9'-0" 105
106 BREAK LVT 4" RC E-PGWB E-PGWB E-PGWB I PGWB E-SAT 9'-0" 1-- 106 CPT
R
CPT LVT
CARPET TO LVT DETAIL