Report (3) 0/44
Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
I 5414,\____ ce " , am the general contractor or the owner-builder
at the following address:
Site Address: /6_1/ /20 5//o 760
City:
Pert#: VIA 57- 2:o Z/
Subdivision/Lot#: 1 R C ' °v 'I 0/C 6
and/or 1 "
Map and Tax Lot#:
To conform with the 2008 Oregon Residential Specialty Code(ORSC), Section R318.2 and
OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement.
[Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes,the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
Signature: Date: 3
-..'ra 7.741gYr- wilder
I:\Building\Form\RES-MoistureSensitiveWood.doc 09/25/08
Oregon Residential Specialty Code R408.1
MOISTURE BARRIER ACKNOWLEDGEMENT FORM
I, S9/4A -,f f , am the general contractor or the owner-builder
at the following address: �f
Site Address: /4/ /6 � C /,,, -�` 4- e _
City: l l l J
5 A-,--) ,
Permit#: j 57 7/-)Z,1 — P-(
Subdivision/Lot#: t er ,Q+e (2 (,') ,
and/or
Map and Tax Lot#:
To conform with the 2014 Oregon Residential Specialty Code(ORSC), Section R408.1
Ventilation. I am notifying the building official that I have installed the Moisture Barrier as per
Requirement in ORSC Section 408.1 and have taken the following steps to meet this code
requirement:
�,� The ground surface of the under-floor space is covered with 6-mil black polyethylene
sheeting with
Joints lapped 12" at seams and
Extending up the foundation walls 12".
Signature: Date: 3/56 / Tim
General r uilder
I:\Building\Fonn\RES-MoistureBurier.doc 09/13/2016
Oregon Residential Specialty Code N1107.2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
Permit No.: �/j t $f )(�( �2" //_ Jurisdiction: _/
v� ,S^^^7YY7"'UUU
Site Address: `[ / �/00 C //a5- �J
Subdivision/Lot#: ( J(�1� / ( �/6I /?`4'l
and/or
Map and Tax Lot#:
By my signature below, I certify that a minimum of fifty(50)percent of the permanently
installed lighting fixtures in the above mentioned building have been installed with compact or
linear fluorescent, or a lighting source that has a minimum efficacy of 40 lumens per input watt.
(Oregon Residential Specialty Code NI 107.2)1
Signature: Date: 3/30Z,,-
Owne LGe 777-.n. •cto '7uthorized Agent
Print Name: 5 i` 5601'
ORSC Section N1107.2.High-efficiency interior lighting systems. A minimum of fifty(50)percent o the
permanently installed lighting fixtures shall be installed with compact or linear fluorescent,or a lighting source that
has a minimum efficacy of 40 lumens per input watt. Screw-in compact fluorescent lamps comply with this
requirement.
The building official shall be notified in writing at the final inspection that a minimum of fifty percent of the
permanently installed lighting fixtures are compact or linear fluorescent,or a minimum efficacy of 40 lumens per
input watt.
I:\Building\Forms\RES-HighEfficiencyLighting.doc 07/01/08