PFI2022-00088 n CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT
a COMMUNITY DEVELOPMENT Permitm PF12022-00088
13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Date Issued: 03/17/2022
Parcel: SEG2007
Jurisdiction: Tigard
Site address:
Subdivision: Lot:
Project: PGE Job#M3070627
Project Description: SEG2007/PGE permit for parking and flaggers.All work will be done on customer property. PGE to pull
wire through customer installed conduit. PGE to install/remove overhead facilities
Class of Work: FEES
Type 1 -Utilities (gas, electric,data) Description Date Amount
Total
Owner:
REQUIRED INSPECTIONS
Call 503-639-4175 for the IVR inspection request line or visit the City of
PHONE: Tigard website at www.tigard-or.gov to schedule inspections online.
Contractor:
PHONE:
Applicant:
JEREMY SPRAGUE
2213 SW 153RD DR.
BEAVERTON, OR 97003
PHONE: 5036725446
Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact
information of responsible parties before beginning work.
Permittee/Applicant
Signature: See application
Issued By:
Special Conditions(See Attached)
Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY
Conditions for PF12022-00088
Type: Condition Name: Status: Severity:
PFI_Utilities 01 -WORK SITE REQUIREMENTS Applied Notice
Applicant must comply with all applicable provisions of federal and state law,the Tigard Municipal Code, and the terms of any
agreement with the City of Tigard regarding work to be done pursuant to this permit.
PFI_Utilities 02-WORK SITE AREA Applied Notice
The work area and approach roads shall be maintained in a clean condition,free from obstructions and hazards. The
spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited and
violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up and
suspension of work to accomplish clean-up.
PFI_Utilities 03-WORK SITE EROSION CONTROL Applied Notice
Prior to starting work, effective and approved erosion control devices must be installed and maintained meeting the Clean
Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to
accomplish effective erosion control.
PFI_Utilities 04-WORK SITE REPAIRS Applied Notice
Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings, mailboxes,etc. shall be
reinstalled or replaced,with like kind of material. Obtain City approval of restoration work.
PFI_Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice
Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices
[MUTCD]for Streets and Highways", U.S. Dept. of Transportation, FHWA, current edition,American Traffic Safety Services
Association [ATSSA], and Oregon Temporary Traffic Control Handbook [OTTCH].
PFI_Utilities 06-TRAFFIC CONTROL PLAN Applied Notice
Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work area.
Traffic control devices,flag persons,etc., shall be in place prior to initiation of construction work and shall be effectively
maintained.
PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice
Public roadway shall not be closed to traffic, at any time, without obtaining written approval from the City Engineer. The
applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and area
wide Emergency Services: 503-629-0111 (Tigard Police Dept., Tualatin Fire& Rescue) and to 503-962-8140(Tri-Met) and
503-431-2345(Tigard School District) and other service providers impacted by such closure.
PFI_Utilities 08 -TRAFFIC CONTROL ADVANCE WARNING Applied Notice
Advance warning of traffic disruption shall be provided to the public by placement of an approved advance notification sign at
each end of the construction area 72 hours(min.) before initiation of construction work.
PFI_Utilities 09-TRAFFIC CONTROL PROPERTY ACCESS Applied Notice
Access to existing properties shall be maintained at all times, including normal delivery service and mail service. Obtain City
approval of any access closures.
PFI_Utilities 10-TRAFFIC CONTROL WORK HOURS Applied Notice
Work is permitted in daylight between the hours of 7:00 a.m.to 7:00 p.m. Mon-Fri unless otherwise authorized by the City.
PFI_Utilities 11 -TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice
Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the City
Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m.to 9:00 a.m. unless authorized by the
City Engineer.
PFI_Utilities 12-TRAFFIC CONTROL MODIFICATION Applied Notice
The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to
assure public safety.
PFI_Utilities 13-DRAINAGE CONTROL Applied Notice
Drainage shall be controlled within the work site and shall not adversely affect adjacent private property, public property and
the receiving system. The City may at any time order corrective action and suspension of work to accomplish effective
drainage control.
PFI_Utilities 14-UTILITY NOTIFICATION Applied Notice
Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR
952-001-0100 through OAR 952-001-0080. Copies of said rules may be obtained from the Center by calling 503-246-1987. If
you have any question about the rules, contact the Center. NOTE: Damage to utilities shall be corrected at the permit
holder's expense.
PFI_Utilities 15-UTILITY LOCATION CONFLICT Applied Notice
Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole before
digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at the
applicant's expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work with
affected utility agencies.
PFI_Utilities 16-TEMPORARY PATCH Applied Notice
A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance
approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is
liable for hazards or damage resulting from the prosecution of the work.
PFI_Utilities 17-REPAIR OF EXISTING FACILITIES Applied Notice
Work under this permit shall include repair of existing facilities (roads, ditches, etc.)as may be necessary,as determined by
the Inspector,to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit.
Corrective work shall be done at the applicant's expense.
PFI_Utilities 19-PRECONSTRUCTION MEETING Applied Notice
Before initiating any construction activity, the applicant shall coordinate with the City's inspector, <Insert Name>at<Insert
Phone#>, to establish a preconstruction meeting.
PFI_Utilities 20-NOTICE TO COMMENCE WORK Applied Notice
The applicant shall notify the City's Inspector twenty-four(24) hours prior to commencing work, prior to any staged inspection,
and after completing work covered by the permit.
PFI_Utilities 21 -PERMIT/PLAN ON SITE Applied Notice
A copy of the permit including a Certificate of Insurance, and all attachments, and a copy of the approved construction plan
and all amendments shall be readily available at the work area. All work shall conform to the permit terms,conditions and
provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and
specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work
performance.
PFI_Utilities 22-DAILY INSPECTION REPORTS Applied Notice
Applicant shall submit daily inspection reports, on a weekly basis,to the City's Inspector.
PFI_Utilities 23-MONUMENT PROTECTION Applied Notice
Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holder's
expense.
PFI_Utilities 24-VALIDATION OF MATERIAUCONSTRUCTION Applied Notice
The City's Inspector may, at his discretion, require tests and or reports from the applicant to validate claims of material or
construction adequacy/compliance. Such tests/reports shall be provided at the applicant's expense.
PFI_Utilities 25-EMERGENCY CONTACTS Applied Notice
Provide to the City inspector, in writing,the names and 24 hour emergency telephone number of two(2)persons who have
authority to resolve problems, take corrective action and, in general,will be responsible in case of any emergency. The
applicant shall notify the City Inspector, in writing, of any/all assignment changes.
PFI_Utilities 26- RIGHT OF ENTRY/EASEMENTS Applied Notice
Applicant to obtain proper right-of-entry and/or easements prior to starting work. Proof of right-of-entry or properly executed
easements, shall be provided to the City. The City shall in no way be construed to be liable for the applicant's failure to obtain
or provide for proof of right-of-entry or easements.
PFI_Utilities 27- PRIVATE PROPERTY AGREEMENTS Applied Notice
Provide the City a copy of an executed agreement[s]from the owner for each private property disturbed by construction
activity.
PFI_Utilities 28 -AS-BUILT DRAWING Applied Notice
1,2,3,4,5 28 -AS-BUILT DRAWING
One as-built drawing showing all new public improvements, including any revision made to the previously approved
construction plans and, also, any improvement which may impact an existing public system or facility, shall be provided to the
City by a registered civil engineer along with an engineer's certification of installation compliance (Certificate of Compliance).
1,2,3,4,5 28-AS-BUILT DRAWING
One as-built drawing showing all new public improvements, including any revision made to the previously approved
construction plans and,also, any improvement which may impact an existing public system or facility, shall be provided to the
City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance).
One as-built drawing showing all new public improvements, including any revision made to the previously approved
construction plans and, also, any improvement which may impact an existing public system or facility, shall be provided to the
City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance).
PFI—Utilities 31 -OTHER Applied Notice
Other
City of Tigard PFI#: PF12022-00088
s ENGINEERING DEPARTMENT
Public Facilities Improvement (PFI) Permit
PROJECT INFORMATION
PGE Job # M3070627 TYPE OF WORK
Project name: a TYPE I—Franchise Utility Work
Brief description of project: PGE just needs permit for parking and flaggers. performed
rmedby NWN,PGE, or utility
agency
All work will be done on customer property. PGE to pull ❑ TYPE 2—ROW Sidewalk/Driveway/Sewer
wire through customer installed conduit. PGE to install/remove overhead facilities. Work performed for the purpose of
• Sidewalk installation or repair
• Driveway approach installation and repair
SITE INFORMATION • Sanitary sewer lateral installation and
Location (address if available):
14845 SW 100th Ave main line tap
❑ TYPE 3—Pug Scale Development Work
Tigard, OR 97224 performed with land use approval which
includes any of the following.
• Subdivisions or Partitions
APPLICANT INFORMATION • Streetwidening
Name: PGE [Submitted by Jeremy Sprague] • Mainline installation for sanitary sewer,
storm sewer, Tigard water, and Tigard
Mailing address: 2213 SW 153rd Dr water service area
City/State: Beaverton/OR Zip: 97003 El TWE 4—Small Cell Technology
Phone:
(503) 672-5446 ❑ TYPE S—Tigard Triangle
Email: crewcoordination-western@pgn.com phone: (503) 464-7777
NOTE: Type 1 and 2 applications may be
Contact name: Jose Velasco emailed to rowncrinits(tr),tigard-ocnov.
Phone: (503) 672-5454 Email: crewcoordination-western@pgn.com
CONTRACTOR INFORMATION M Same as applicant
Name: PGE Crew CCB Number:
Mailing address: City/State: zip:
Phone: (503) 464-7777 Email: crewcoordination-western@pgn.com
ENGINEER INFORMATION
Name: PGE Crew
Mailing address: City/State: Zip:
Phone: Email:
ADDITIONAL INFORMATION
Estimated value of workis required(if over$5,000):$ (within the public right-of-way)
Is work related to a LAND USE DECISION? OYes 0 No Case number:
City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 • Page 1 of 4
APPLICANTS
NOTE: Person specified as"Applicant"shall be designated"Permittee"and shall provide financial assurance for
work,if required by the city pursuant to TMC 15.04.140.
* With the exception of a utility operating pursuant to a valid franchise or license with the City of Tigard,when the owner and the applicant
are different people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner
or an agent of the owner. The owner must sign this application in the space provided or submit a written authorization with this
application. Franchised or Licensed Utilities are not required to obtain the owner's signature on the application.
I,the applicant,certify that:
• To the best of my knowledge, all the information provided within this application package is complete and
accurate.
• The above request does not violate any recorded deed restrictions that may be attached to or imposed upon the
subject property.
• If the application is granted,I will exercise the rights granted in accordance with the terms and subject to all the
conditions and limitations of the approval.
Jeremy Sprague 03/10/2022
Applica s or au orized agent's signature Print name Date
Property owner's signature (if required) Print name Date
STAFF USE ONLY
Case No: PF12022-00088 Permit fee: .(5r- Received by: NT Date: 3/10122
Approved by: Tyrdn ,e7 Date: 3I/�ley2> Notified by: ltv Date: 3 l7 `L2
'City of Tigard 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-orgov • 503-718-2421 9 Page 2 of 4
DEVELOPMENT ENGINEERING FEES
Public Facility Improvement(PFI)Permit.-
INITIAL
ermit:INITIAL PFI PERMIT FEE
Part 1: Requited submittal fee is 10%of the Net PFI Permit Fee.See below for calculations.Minimum of$300.
NET PFI PERMIT FEE
Part 2: All non-water system improvements engineer's estimate X 7%(less the initial PFI Permit Fee).
WATER LINE CONSTRUCTION FEE
Part 3: All public water system improvements engineer's estimate X 12%.
FOR STAFF USE ONLY FOR STAFF USE ONLY
SUBMITTALTYPE 4: SMALL WIRELESS FACILITY TYPE 1-3:DETAILED
REQUIREMENTS
CHECKLIST
Does applicant have a right-of-way license? ❑Yes ❑No TYPE 1 AND TYPE 2-Must include a sketch
showing:
Under the wireless facilities standards,is the proposal
❑ Dimensions
considered?(check all that apply): ❑Small Cell ❑Macro ❑ Street Name
How many install sites are proposed as part of this permit ❑ Site Address
application?
TYPE 3-Must provide 4 sets of plans (sized 24 x 36
or 22 x 34) and an electronic version of all submittal
The proposed equipment is located on which of the following: items. The plans must that include:
❑Public Right-of-Way ❑Private Property
❑ Cover—Site,Vicinity,Abbreviation,Legend
If equipment is to be located on private property,describe the ❑ General Notes(City,Water,Sewer,etc.)
type&use: ❑ Street(Plan,Profile)
❑ Water,Storm and Sanitary(Plan Profile)
❑ Water Quality Facilities
❑ Grading
❑ Landscaping/Tree Plan
❑ Composite Utility Plan(Electrical,Phone,Gas, Storm,
Sanitary,Water,Signage,Street Lights,etc)
❑ Details
❑ Traffic Sight Distance
❑ Signing and Striping
❑ Street Light Plan and Photometric
❑ Engineers seal/signature
❑ Sheet label(project land use name,revision and plan
log block,dates and sheet numbers.)
❑ Engineers Construction Estimate
Additional Submittals
(per land use conditions,if applicable)
❑ Traffic Report
❑ Storm water Drainage Calculations
❑ Geotechnical Report
❑ Preliminary Access Report(Sight Distance)
❑ Proposed Plat
❑ Pathway Design
❑ Water Provider Approval
Cityof Tigard 13125 SW Hall Blvd. Tigard,Oregon 97223 • wwwdgard-or.gov • 503-718-2421 • Page 3 of 4
SW .. •' C' I
Edge of Pavement
I t— Ditch —►
Streetlight I --- —'— —r—'—
' 1
i 7'�iopos cf'SeliverTirie 1
I _ 1
al
I 11Nz;l j Existing House
Ewsting
1
j
rl I it Driveway
al y'c I q"* �•
qo ` 1
d CID
°I FxistingShop j
Powerpole I I o l o 1
Properly —.—.—.—.—.
Q1 Fire Hydrant(FH)
I I I
I
Scale: 1-=30'
� I I
TYPE 1 AND
I I I
� I I
i � I
TYPE
MINIUM SKETCH REQUIREMENTS (PLIt N/A if not applicable)
North arrow Property lines&dimensions Existing utilities locations
(sewer, storm,water)
Street&street names All existing structures
Proposed work Existing curb or edge of pavement Utility&street light poles
Existing S/W or D/W apron Slope of property Trees
City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 9 www.tigard-or.gov • 503-718-2421 • Page 4 of 4
z SINGLE FAMILY LEGEND
NEW PGE FACILITIES TO BE INSTALLED
(UNLESS OTHERWISE SPECIFIED)
REMOVE FACILITIES INSTALL FACILITIES
V _______ INSTALL I-350 AL-TX UG SECONDARY IN 3'PVC
ART ayT CONDUIT.PROVIDED B INSTALLED BY CUSTOMER
•Q;
IWMMIIODCR}T RO}B Bich24' All, SPDE
4101411112 AIR y 4yY ].14 NY1 TYPIC
hip wi LEGEND
» W1e ° �„ M PGE PUmaryf
am Nn aRr M• MN1 O Secondary Cable
THINK = T � Gove Inside D DI
B Tal.I CAW
SAFETY . 1O' ®Backfill
FIRST! A oSelect III
i t2'Mir O
Ursdaludiand
Berlin
W C21-118 �
i PL-1394 Joint Use Trench WO Gas
R 7A2533597 CONSTRUCTION NOTES: SFEXT
L0l TALLW A REMOVE
12024th 142 CC FIU
3IOAMP 7200V,12M40V.1 0,3"
/4KW EXIST 1.CUSTOMER TO PROVIDE ALL TRENCHING AND BACKFILLING. TRENCHTOBE
HP/AC"'R 21MADDED �L. 3d INCHES(�DD�EEP MEASURED FROM FINAL GRADE
104R6FLKR BSRW TOTAL w FRAD CONCON13UIT PATH NYLON WILL
BETRRINGk MIN SMOLOESE TEEST1T1gICAL GRADE.
8.613A AEC PGE TO DETERMINE THE SIZE AND NUMBEN OF CONDUITS REQUIRED
MAINTAIN 12 VERTICAL INCHES AND 24 HORIZONTAL INCHES CLEARANCE BETWEEN
100 A GAS ANO OTHER UTILITIES ALL ELBOWS TO BEY MfII'1MINI RADIUS
___-______ 3' /Ill BEN DSMUSTBEFACTORYMADE RIGIDSTEELON POEAPPISVEDRBERGEASS
ElE—� CONDUIT BENDS ARE REQUIRED FOR RUNS OF 151 FEET OR LONGER OR FOR ANY LENGTH
I I RM Ens RUN WITH MO BE THAN I SO DEGREES IN SENDS.PVC SCHEDULE 40 BENDS ME
61 ACCEPTASLEFOR RUNS OF ISO FEETOR LESS.THE MAXIMUM TOTAL BENDS MANY
RN CONDUIT RUN Is 200 DEGREES.
INSTALL T POLE CONDOR UNIT 2 A PGE STANDBY CREW IS REQUR ED FOR OPENING ALL ENERGIZED POE VAULTS
W/17 BRACKETS 8 WEATHERIIEADJUNCTDN BOXES AND EQUIPMENTFACILITIE6 INCLUDING CONNECTION OR INSiH UTION
- -' OF CONpUIT$ANS PULL STRINGS CALL SERVICE COORDINATION AT 503.9238700
TO SCHEDULE A PGE STANDBY CREW
ONLY
-" 3.CU ELECTRICAL
ORADE.SNTI ONOUNT D BBOSMNG6 LS STRINGS
(MIN 6 11 LB&TEST),
ELECTRICAL GRADE.PVL CONDUR WITH NYLON PULL STRINGS(LR1.IT00 LBS.TEST)
an 4 RDREQUIREMENTS
M�KMOPE POLYETHYLENE
RN ECCIOSCH UE �WTH AMWCATCPINJCTREO MHALCONNECTIOL� GTHMECATIDHEND
EET THE
REQUIREMENTS OF P
SPECIFICATION LMMI UVAILIBLE ON REQUEST FROM POE PROJECT
MMINGER1.FOR SAFETY REASONS THE DUCT SHALL BE BIACK W TN THREE EQUALLY SPACE
-�-'• EXTRUDED RED STRIPES IVMICH IS A SPECIFICATION REOUIREMENTI.MANDREL TEST OF
RIGHT-OF-WAY PERMIT NOTICE'. HDPE PIPE IS REQUIREp AFTER INSTALLATION WITH ME INSPECTOR PRESENT
1 �C =.w•- APER IN FROM THELOCAL OF-WAY MAYBE
IER IS BEFORE MY S.SINGLE PRIMER YIN5TAl1ATpNS-0ONDUT TO EXTEND MINIMUM OF IG FROM
,IIP '++';:^Q WORK IN THE RIGHT CO WAY MAV BE PERFORMED. ONLY PGE APPROVED ALL PSFORMPR PAD. (
q � ^j•v - AGREEMENTS
ANDWITH GEWU BEALLWHO WED TO WORK
UNDER
FRIECIAL e. BUILDING T VI OR OOVERTO
NGE AND FFEETB1MInE1 FROIMIARY MR MVQOnMANBUSTIBLE
O A3iEEMENT3 WITH PGEWLLBE ALLOWED TO NORK UNDER PCE'S PERMIT PGETM SFORMERS MUST BE"THIN IS FEE OF ADRNEABLEAREA
�( „y,N, -'*- THE CONTRACTOR MUST NOTIFY THE LOCAL JURISDICTION 4B HOURS ALWAYS NAINTAN•O FEET CLEARANCE IN FRONT OF ALL TRANSFONMERS.
N 1^: �' BEFORE WORK IS TO BEGIN,A COPY OF THE PERMIT MUST BE ON SITE. 7 CUSTOMER TRENCH AND ELBOW COMIOWAl10N8 MUST M INSPEOIED BY POE P1RDR To
SMII YALUMO.WIZEN YOU ARE READY FOL9004542.RR ME TO INSPECT(AFTER MBTALLATKIN IB COMPLETED
ALLLOO`W UCALL
TLO 2 WORKING DAYS PER IN TION TO OCg1R
Y • ""Ai = CONTACT SERVICE COORDINATOR
j 'Fr yw�M' FOR 7RENCJ1 AM CONDUIT INSPECTION PRIOR S DESIGNROUND 15 EQUIPMENT
STANDARD BE EROgOL AT AN FM.N COST TO
SF. TO WKRLL.PGE WLL NOT INSTALL WrIE UNDERGROUND EOUIM.ENT MAY BEANOPTKNI AT ANAmITION1UL CAST TO THE CUSTOMER.
E UNTIL TRENCH IS 100%BACKPILLFF PGE CONSTRUCTION DRAWING
..� SERWCE COOImMATOR
603-32'3-6700 OR 000.642-8818 DATE "IN, ANO IDS NQ
A.e�.•.0 i�. P '2/148022 NTS [ACCOUNT,1070001 100000/594 -M3070827
SwMURDDCKSE ANY DEVIATION FROM THIS DESIGN MUST TB
^�' I BE APPROVED BY PGE PROJECT MANAGER ` IRCIFT BEY R BARYON s�
4 ! TIGARD-TIGARD 13 11X17
i
I JOB SITE ATTENTION: CALL 811 BEFORE YOU DIG PPGE Loargx:
1 �mn GON LAW REQUIRES YOU TO FOLLOW RULES ADOPTED 118/6 SW ZOOM AW TIGARD
V THENTER
OREGON UTILITY NOTIFICATION CE . GEsenlPrgN.
THOSE RULESARE SET FORTO
H IN AR 952-001-0001
..H , UOrgride 120810v 3208 1 ph Service to Existing Home
x THE UGES BYC -0 100.CALLING
YOU OREGOAY N
IN TILITY ES OF couxTY 5C21.11B WORK WTx: WEE
THE RULES BY CALLING THE DREfiON UTILT(Y SCREW CON
I�,�,-- OTIFlCATION CEMERADMNSTINiIONO(0D3-232-198]) LJNE CREW CENTER WASHINGTON C21-118
cesl0x er PHONE72-454 7A"NE"r:
EwaER'ue'.•-• j TORILITYN TIFCATONLOCATES ENTER$11 AT OREG'��. �,�5�I�,. Jose Vebsm 672-6154 IANE WHITNEY
UTILITY NOTIFICATION CENTER 911 AT LEAS' CBII DehxB }sW 15>co0a
2 BUSINESS DAYS PRIOR TO EXCAVATION. 1TM dg. E.1vTRrw.G9srme OPORTLAND GENERAL ELECTRIC CO.-ALL RIGHTS RESERVED
Page 84 2011 Edition
Stationary Lane Closure with Flagging Diagram 320
Diagram 320 covers total closure of one lane of a two-lane, two-way
roadway. See the detail inset for the layout if using a single flagger to control
both directions of traffic on low volume roads(less than 400 ADT)with good
sight distance as discussed below.
1. Use truck-mounted flashing warning lights on work and protection
vehicles. See Section 4.3—Lights and Lighted Signs for exceptions.
2. For added visibility, a truck-mounted arrow board or PCMS in caution
mode may be used.
3. Flaggers at each approach are required if any of the following
conditions exist
a. Night Operations.
b. Work space is over 200 feet in length.
c. Sight distance is less than 750 feet from each approach
through the lane closure.
d. Traffic volumes are greater than 400 ADT.
4. The length between the Flagger Ahead signs shall not exceed one
mile. Use Diagram 340—Lane Closure with Pilot Car if exceeding one
mile.
5. Cones should be used to outline the work space when curves or other
roadway alignments prevent clear direction for the motorists to pass
the work space safely.
6. Cones along the work space are recommended when posted speeds
are 45 mph or greater,when working under heavy traffic or when travel
lanes are narrower than 11 feet.
7. Extended queue signing (see Diagram 5-4) should be used when
traffic queues extend beyond the initial advance warning sign.
8. When flagging near an intersection, the "Flagger Ahead" (CW23-2)
sign should be visible to traffic entering from any side road. Additional
advance warning and Flagger Ahead symbol signs may be placed on
the side road(s).
9. Sign set-up and Flagger placement shown may be used for intermittent
full road closures of 20 minutes or less.
10. The"ONE LANE ROAD AHEAD" (W20-4)sign is optional and should
be considered on high volume or high speed roads, or when extended
queues are expected.
Chapter 5 December 2011
2011 Edition Page 85
Stationary Lane Closure with Flagging Diagram 320
O O u] C
¢3¢ ; O
Yy
'V
w CD
a
n ¢ O
0 0
m
rn
• rn
W a 1 1 to
wm°day rn ,
O
a ,
• m c
WO
----------------
I
o • �0
I °mL)
R 4 t lit EL
<�
I o I'� • m
CL �� •
CD j I •
to Os e
LL J
mo 1 Y. 1 m m Lu
fA 1 t V I a 1O
r I
Sign Spacing and Buffer Lengths(feet) J 1 t Q^
ERRATA: - Posted Spacing Between Signs Buffer m p
Speed q g C Space ,L 0
20 50 o
supplement Table 25 100 100 100 775--
30 100
INtletetl:February l2, 35 125 Y
2016 40 350 350 350 150 O O=
ey:000rirs6ceoatlwry 45 180 ¢3 Q
Siidtoa 50 500 500 500 210
55 250
51 zn SWIng and Buffer Lengths feet Su> lement
December 2011 Posted S adn Between Si ns "Buffer" Chapter 5
Speed A B C 5 ace
60 285
65 700 700 700 325
70 365