PFI2022-00072 CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT
s COMMUNITY DEVELOPMENT Permit#: PF12022-00072
13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Data Issued: 03/08/2022
Parcel: SEG3920
Jurisdiction: Tigard
Site address:
Subdivision: Lot:
Project: Comcast#221521 South River Terrace
Project Description: Comcast proposes to route cable through existing conduit between existing facilities; SEG 3920
Class of Work: FEES
Type 1 -Utilities (gas, electric,data) Description Date Amount
PFI Permit Fee 03/08/2022 $300.00
Total $300.00
Owner:
REQUIRED INSPECTIONS
Call 503-639-4175 for the IVR inspection request line or visit the City of
PHONE: Tigard website at www.tiaard-or.gov to schedule inspections online.
Contractor:
PHONE.
Applicant:
MITCH BURGHELEA
11308 SW 68TH PARKWAY
TIGARD, OR 97223
PHONE: 5037985785
Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact
information of responsible parties before beginning work.
Permittee/Applicant
Signature: See application
Issued By: &2'LL Lnk
Special Conditions(See Attached)
Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY
Conditions for PF12022-00072
Tyne: Condition Name: Status: Severity:
PFI_Utilities 01 -WORK SITE REQUIREMENTS Applied Notice
Applicant must comply with all applicable provisions of federal and state law,the Tigard Municipal Code, and the terms of any
agreement with the City of Tigard regarding work to be done pursuant to this permit.
PFI_Utilities 02-WORK SITE AREA Applied Notice
The work area and approach roads shall be maintained in a clean condition, free from obstructions and hazards. The
spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited and
violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up and
suspension of work to accomplish clean-up.
PFI_Utilities 03-WORK SITE EROSION CONTROL Applied Notice
Prior to starting work, effective and approved erosion control devices must be installed and maintained meeting the Clean
Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to
accomplish effective erosion control.
PFI_Utilities 04-WORK SITE REPAIRS Applied Notice
Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings, mailboxes, etc. shall be
reinstalled or replaced,with like kind of material. Obtain City approval of restoration work.
PFI_Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice
Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices
[MUTCD]for Streets and Highways", U.S. Dept. of Transportation, FHWA, current edition,American Traffic Safety Services
Association [ATSSA], and Oregon Temporary Traffic Control Handbook[OTTCH].
PFI_Utilities 06-TRAFFIC CONTROL PLAN Applied Notice
Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work area.
Traffic control devices, flag persons, etc., shall be in place prior to initiation of construction work and shall be effectively
maintained.
PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice
Public roadway shall not be closed to traffic, at any time,without obtaining written approval from the City Engineer. The
applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and area
wide Emergency Services: 503-629-0111 (Tigard Police Dept.,Tualatin Fire& Rescue)and to 503-962-8140(Tri-Met)and
503-431-2345(Tigard School District)and other service providers impacted by such closure.
PFI_Utilities 08 -TRAFFIC CONTROL ADVANCE WARNING Applied Notice
Advance warning of traffic disruption shall be provided to the public by placement of an approved advance notification sign at
each end of the construction area 72 hours(min.) before initiation of construction work.
PFI_Utilities 09-TRAFFIC CONTROL PROPERTY ACCESS Applied Notice
Access to existing properties shall be maintained at all times, including normal delivery service and mail service. Obtain City
approval of any access closures.
PFI_Utilities 10-TRAFFIC CONTROL WORK HOURS Applied Notice
Work is permitted in daylight between the hours of 7:00 a.m.to 7:00 p.m_ Mon-Fri unless otherwise authorized by the City.
PFI_Utilities 11 -TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice
Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the City
Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m.to 9.00 a.m. unless authorized by the
City Engineer.
PFI_Utilities 12-TRAFFIC CONTROL MODIFICATION Applied Notice
The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to
assure public safety.
PFI_Utilities 13-DRAINAGE CONTROL Applied Notice
Drainage shall be controlled within the work site and shall not adversely affect adjacent private property, public property and
the receiving system. The City may at any time order corrective action and suspension of work to accomplish effective
drainage control.
PFI_Utilities 14-UTILITY NOTIFICATION Applied Notice
Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR
952-001-0100 through OAR 952-001-0080. Copies of said rules may be obtained from the Center by calling 503-246-1987. If
you have any question about the rules, contact the Center. NOTE: Damage to utilities shall be corrected at the permit
holder's expense.
PFI_Utilities 15-UTILITY LOCATION CONFLICT Applied Notice
Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole before
digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at the
applicant's expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work with
affected utility agencies.
PFI_Utilities 16-TEMPORARY PATCH Applied Notice
A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance
approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is
liable for hazards or damage resulting from the prosecution of the work.
PFI_Utilities 17-REPAIR OF EXISTING FACILITIES Applied Notice
Work under this permit shall include repair of existing facilities(roads,ditches, etc.)as may be necessary, as determined by
the Inspector,to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit.
Corrective work shall be done at the applicant's expense.
PFI_Utilities 19-PRECONSTRUCTION MEETING Applied Notice
Before initiating any construction activity, the applicant shall coordinate with the City's inspector, <Insert Name>at<Insert
Phone#>,to establish a preconstruction meeting.
PFI_Utilities 20-NOTICE TO COMMENCE WORK Applied Notice
The applicant shall notify the City's Inspector twenty-four(24) hours prior to commencing work, prior to any staged inspection,
and after completing work covered by the permit.
PFI_Utilities 21 -PERMIT/PLAN ON SITE Applied Notice
A copy of the permit including a Certificate of Insurance, and all attachments, and a copy of the approved construction plan
and all amendments shall be readily available at the work area. All work shall conform to the permit terms, conditions and
provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and
specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work
performance.
PFI_Utilities 22-DAILY INSPECTION REPORTS Applied Notice
Applicant shall submit daily inspection reports, on a weekly basis,to the City's Inspector.
PFI_Utilities 23-MONUMENT PROTECTION Applied Notice
Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holder's
expense.
PFI_Utilities 24-VALIDATION OF MATERIAL/CONSTRUCTION Applied Notice
The City's Inspector may, at his discretion, require tests and or reports from the applicant to validate claims of material or
construction adequacy/compliance. Such tests/reports shall be provided at the applicant's expense.
PFI_Utilities 25-EMERGENCY CONTACTS Applied Notice
Provide to the City inspector, in writing, the names and 24 hour emergency telephone number of two(2) persons who have
authority to resolve problems, take corrective action and, in general,will be responsible in case of any emergency. The
applicant shall notify the City Inspector, in writing,of any/all assignment changes.
PFI_Utilities 26-RIGHT OF ENTRY/EASEMENTS Applied Notice
Applicant to obtain proper right-of-entry and/or easements prior to starting work. Proof of right-of-entry or properly executed
easements, shall be provided to the City. The City shall in no way be construed to be liable for the applicant's failure to obtain
or provide for proof of right-of-entry or easements.
PFI_Utilities 27 -PRIVATE PROPERTY AGREEMENTS Applied Notice
Provide the City a copy of an executed agreement[s]from the owner for each private property disturbed by construction
activity.
PFI_Utilities 28-AS-BUILT DRAWING Applied Notice
1,2,3,4,5 28-AS-BUILT DRAWING
One as-built drawing showing all new public improvements, including any revision made to the previously approved
construction plans and,also,any improvement which may impact an existing public system or facility,shall be provided to the
City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance).
1,2,3,4,5 28-AS-BUILT DRAWING
One as-built drawing showing all new public improvements, including any revision made to the previously approved
construction plans and,also, any improvement which may impact an existing public system or facility, shall be provided to the
City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance).
One as-built drawing showing all new public improvements, including any revision made to the previously approved
construction plans and, also, any improvement which may impact an existing public system or facility, shall be provided to the
City by a registered civil engineer along with an engineer's certification of installation compliance (Certificate of Compliance).
PFI_Utilities 31 -OTHER Applied Notice
Other
City of Tigard p I#: 2022-00072
ENGINEERING DEPARTMENT
. Public Facilities Improvement (PFI) Permit
PROJECT INFORMATION
TYPE OF WORK
221521 - South River Terrace Ph 1
Project name: 8 TYPE 1—Franchise Utility Work
Brief description of project: Comcast proposes to route cable through performed by NWN,PGE, or utility
agency
existing conduit between existing facilities. ❑ TYPE 2—ROW Sidewalk/Driveway/Sewer
Work performed for the purpose of:
• Sidewalk installation or repair
• Driveway approach installation and repair
SITE INFORMATION • Sanitary sewer lateral installation and
Location (address if available):
SW Bull Mountain Rd & SW River main line tap
❑ TYPE 3—Full Scale Development Work
Terrace Blvd, Tigard, OR 97224 performed with land use approval which
includes any of the following.
• Subdivisions or Partitions
APPLICANT INFORMATION • Streetwidening
Name: Comcast • Mainline installation for sanitary sewer,
storm sewer, Tigard water, and Tigard
Mailing address: 11308 SW 68th Parkway water service area
City/State: Tigard, OR Zip: 97223 ❑ TYPE 4—Small Cell Technology
Phone:
(503) 798-5785 ❑ TYPE 5—Tigard Triangle
Email: Mircea_Burghelea@comcastcom Phone: (503) 798-5785 NOTE: Type 1 and 2 applications may be
Contact name: Mitch Burghelea - Construction Specialist emailed to rowrennits tntiard-or.L7Qy.
Phone: (503) 798-5785 Email: Mircea_Burghelea@comcast.com
CONTRACTOR INFORMATION ❑ Same as applicant
Name: Texstar Enterprises, LLC, Attn: Scott Boyles CCB Number: 228361
Mailing address: 14122 Arndt Rd City/State: Aurora, OR /ip: 97002
Phone: (503) 793-3140 Email: scoff.boyles@texstarenterprises.com
ENGINEER INFORMATION
Name: K&B Technical Solutions, Attn: Kyle Browning
Mailing address: 6566 SE Lake Rd, Ste. F City/State: Portland, OR I.ip: 97222
Phone: (719) 244-1608 Email: Permits@kbmail.net
ADDITIONAL INFORMATION
Estimated value of work is required(if over$5,000):$ (within the public right-of-way)
Is work related to a LAND USE DECISION? ❑Yes ®No Case number:
Cityof Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.fiprd-or.gov • 503-718-2421 • Page 1 of 4l
APPLICANTS
NOTE: Person specified as"Applicant"shall be designated"Permittee"and shall provide financial assurance for
work,if required by the city pursuant to TMC 15.04.140.
* With the exception of a utility operating pursuant to a valid franchise or license with the City of Tigard,when the owner and the applicant
are different people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner
or an agent of the owner. The owner roust sign this application in the space provided or submit a written authorization with this
application. Franchised or Licensed Utilities are not required to obtain the owner's signature on the application.
I,the applicant, certify that:
• To the best of my knowledge, all the information provided within this application package is complete and
accurate.
• The above request does not violate any recorded deed restrictions that may be attached to or imposed upon the
subject property.
• If the application is granted,I will exercise the rights granted in accordance with the terms and subject to all the
conditions and limitations of the approval.
Kyle Browning PER= �m - Kyle Browning 3/1/2022
Applicant's or authorized agent's signature Print name Date
Property owner's signature (if required) Print name Date
S'l AFF USE ONLY
Case No: PF12022-00072 Permit fee: SPV 3/1/2022
_,�2•!/y Received by: Date:
Approved by: Date: &174412t? Notified by: AL-- Date:
City of Tigard • 13125 SW Hall Blvd • Tigard,Oregon 97223 wwwtigard-ongov 503-718-2421 Page 2 of 4
DEVELOPMENT ENGINEERING FEES
Public Facility Improvement(PFI)Permit:
INITIAL PFI PERMIT FEE
Part 1: Required submittal fee is 10%of the Net PFI Permit Fee.See below for calculations.Minimum of$300.
NET PFI PERMIT FEE
Part 2: All non-water system improvements engineer's estimate X 7%(less the initial PFI Permit Fee).
WATER LINE CONSTRUCTION FEE
Part 3: All public water system improvements engineer's estimate X 12%.
FOR ONLY • STAFF USE ONLY
TYPE 1-3:DETAILED SUBMITTAL
TYPE 4: SMALL WIRELESS FACILITY REQUIREMENTS
CHECKLIST
Does applicant have a right-of-way license? ❑Yes ❑No TYPE 1 AND TYPE 2-Must include a sketch
showing:
Under the wireless facilities standards,is the proposal ❑ Dimensions
considered?(check all that apply): ❑Small Cell ❑Macro ❑ Street Name
❑ Site Address
How many install sites are proposed as part of this permit
application?
TYPE 3-Must provide 4 sets of plans (sized 24 x 36
or 22 x 34) and an electronic version of all submittal
The proposed equipment is located on which of the following: items. The plans must that include:
❑Public Right-of-Way ❑Private Property
❑ Cover—Site,Vicinity,Abbreviation,Legend
If equipment is to be located on private property,describe the ❑ General Notes(City,Water,Sewer,etc.)
type&use: ❑ Street(Plan,Profile)
❑ Water,Storm and Sanitary(Plan Profile)
❑ Water Quality Facilities
❑ Grading
❑ Landscaping/Tree Plan
❑ Composite Utility Plan(Electrical,Phone,Gas, Storm,
Sanitary,Water,Signage,Street Lights,etc.)
❑ Details
❑ Traffic Sight Distance
❑ Signing and Striping
❑ Street Light Plan and Photometric
❑ Engineers seal/signature
❑ Sheet label(project land use name,revision and plan
log block,dates and sheet numbers.)
❑ Engineer's Construction Estimate
Additional Submittals
(per land use conditions,if applicable)
❑ Traffic Report
❑ Storm water Drainage Calculations
❑ Geotechnical Report
❑ Preliminary Access Report(Sight Distance)
❑ Proposed Plat
❑ Pathway Design
❑ Water Provider Approval
Cityof Tigard 13125 SW Hall Blvd. Tigard,Oregon 97223 • wwwtigard-ozgov • 503-718-2421 • Page3 of 4
Edge of Pavement
Streetlight 1 '~ Ditch
I I a 1
I I
' T-�iopos <I'•Selv✓etTine-' I
I I I
I '-1
W
1 1
- Existing House
I
'y 1 z1 1 Existing
Fi I 3, Driveway
wPF I _ 1
11]
o � I
al
a I I rn°
L lcs
ai ./1 I 1
o'
1 � Existing Shop �
t
Powerpole
o !
I I la--•-- 95 I
Property --------
Fire Hydrant(FH)
I I I
I
Scale: '1"=30'
I
TYPE 1 AND TYPE 2:
MINIUM SKETCH REQUIREMENTS (Put N/A if
I I I
I I I
I I �
ot applicable)
North arrow Property lines&dimensions Existing utilities locations
(sewer,storm,water)
Street&street names All existing structures
Proposed work Existing curb or edge of pavement Utility&street light poles
Existing S/W or D/W apron Slope of property Trees
City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.*rd-or.gov • 503-718-2421 • Page 4 of 4
also oleo 14190 J 14x14 I uzae 1<zrsz 1
eollw I 4208 14320 usMz I I rase luso I 14450 I z a,
luso R
�oJ Iy a
IXIBTMG p`yy�J� }
RVN
PEDESTAL
IbY Im 6 SONE: 1'-BD' Z N
SW DARWIN AVE RP6 1 O
Dw m
leve 1�n 111 6m 0 O
11111114 MIIgY RX
M p N K
16549 18546 16561 leeS4 I 167M 1BT58 5g E%IT ROYINp COMNIUE a cr N Q
_
EXISTING f.OIAGAST%DESTK E%ISTING ] �ARVAIE PROPERTY m CF7
16592 low — — IN CITY OF TnARD ROW PEDESTAL tS 3 f
18581 iK65 19552 loan 16582 O
_ LL
1fi740
PROOF NA VERIFY EMS11NG PATMVAY 16]41 y
18BN 186DB — y — PULL NEW CABLE TNROIK'AI E%ISTINCa COf101M C — � U
F 3 Iola 16961 I 19588 —
166411 Z 19rss
16614
18612 — J
1e6n w _ — } lam
j 15a44 16597 16574 m 16725 s .
18ega/ t°Ba law W 166x5 Z 16&18 Z
3 _ — — N 19T21 — gg
Z 8
— — — FO tease leSrG teal m
161166 §
16670 — N le6u 16712 — 8
pp J C
_ I 1968 I0579 /6188 m
1611" SW DARWIN LP 3 B
tent
E%ABT91G coucarPEuDEsr
tmee 16605 NCITYDFTIGARDROW 14117 m�
—' — — I 197w — 1°°06 16515 1 teen 1 leers 1 REMSTING — �p0 b
LESTAL
WT I taes5
TRAc7D I teen EE
111714 Ism IXISTND E%ISTING 1 15551 IN" TRACT
N. ��
PEDESTAL I legal laNT
eratl - algal PEDESTAL I EXIT ROW AND CONTINUE rf }O
PROOF AND VERIFY
EXISTING
NEW CABLE T11ROl1aH E%RTNG CONOIRT ON PRIVATE PROPERTY m
SW RIVER TERRACE BLVD Q3
:
ew
Mob— MOb� al/
q 1` 0
sou 444U _®
14117 '"::E .�'a
141M 141sT urn `2; oil
U
1.ALL WORK AREAS TO BE RESTORED TO URE OR BETTER OONDITION. F
2.UNDERGROUND UTILITIES HAVE BEEN ROTTED fTNMAAVA6IBLE etc[]
M6b
map RECORDS AND FIELD OBSERVATIONS BUT ARE NOT NECESSARILY E%ACT.
111°/5 SW 168TH AVE '
.A.rr.....�K.rS R IS THE EALL UNDERGROUND
CONIRAGTDR'S OR T OCONS TIY TO FELO
srwr.rrrwms LOCATEALL UNDERGRWND lIl1UT1E5 PRIOR TO CDNSTRUCTIpt
44421 �-'T�T—�— WHEN WORKING OYER dt NEM 6NEWAlIfS:PROVIDE BPOT1ERa TO VOLS PEDESTR6W TMFFIL w��y�r� OOMRETE REPAIR OF ANY AND ALL DAUAGES INCURRED SHALL M AT THE wwec�o
UNTIL CONSTRUCTION CAN BE PAUSED,ORRIS SPF£TO PAS4 TINOIICAI TIIE WORKZONE. �y. E%PENSE OF INE WNRUCTOR OMECd9e6b11T96
Z
3
a
o a
LINETYPES SYMBOLS a o
�W
AERIAL CABLE JOINT USE POLE ®POLE TAG �O N(9EXISTING CONDUIT JOMT USE POLE WI TRANSFORMER SPCLETAG
2d N
NEW CONDUIT ------------------- POWER POLE WI TRANSFORMER SPOLETAG J K N p
RIGHTAP-WAY AW POWER PUCE XPCLETAD m(J Q
EASEMENT OKf CABLE POLE *POLETAG ~ I_
PUBLIC UTILITY EASEMENT RITE TELEPIIONE POLE Q POLE TM N 0
PRDPERTY UNE — E%ISTING CONDUIT RISER
CENTERLINE CA PROPOSED CONDUIT RISER ()
FACE OF CURB Tae PEDESTAL
EDGE OF PAVEMENT EOR VAULTMANDHOLE
EDGE OF CONCRETE m MA E e 0
EDGE OF GRAVEL NIO INLET 0
EDGE OF SIUEWALK *V VALVE pQ K
EXCAVATION LIMBS ----------- METER Q
a
SEWER s HYDRANT YY
STORM SD POWER TRANSFORMER
WATER • STREET LIGHT POLE yj¢
TRAFFIC SIGNAL POLL Q a
POWER -- P SIGNAL CONTROLLER CEO
TELEPHONE CROSS WALK SIGNAL O ppa
FIBER OPTIC .r — RAILROAD SIGNAL
CATV - Ury - TREE O S
TRAFFICSIGNAL i95 CULVERT
STREETLIGHT
FENCE LME x 5
GUARD RAIL ❑ yyy n
RAILROADTRACKS ¢ p
BUILDING FOOTPRINT £� $
OY
a
�� B
(nwK�a
U �L
� oil
e
L
CMEX-99962-15756
Page 80 2011 Edition
5.3 Two-Lane, Two-Way Roads
Shoulder Work w/ Minor Road Encroachment Diag. 300
Use this detail for non-freeway work which extends into a travel lane and
maintains a minimum 10 foot travel lane. If a minimum 10 foot travel lane
cannot be maintained, or when traffic cannot safely pass by in both lanes
simultaneously, use the appropriate lane closure diagrams—for example,
Diagrams 310 through 350.
A lane closure may be appropriate for conditions such as high traffic
volumes, high speeds, and inadequate approach sight distance to the work
space, or heavy equipment adjacent to the travel lane.
1. Use truck-mounted flashing warning lights on work and protection
vehicles. See Section 4.3—Lights and Lighted Signs for exceptions.
2. For added visibility, a truck-mounted arrow board or PCMS in caution
mode may be used.
3. Cones shall be placed along the entire length of the work space. If a
protection vehicle is used and work is in place one hour or less, the
taper and tangent devices may be omitted.
4. If the speed is 45 mph or higher, volumes exceed 2000 ADT, or there
is limited sight distance, consider placing cones or tubular markers on
centerline.
5. An arrow board in caution mode or truck-mounted PCMS with
"SHOULDER WORK" or other appropriate message may be used for
higher visibility.
Sign Spacing and Buffer Lengths(feet)
Posted Spacing Between Signs "Buffer"
Speed A B c Space
20 50
25 100 100 100 75
30 100
35 350 350 350 125
40 150
45 180
50 500 500 500 210
55 250
60 285
65 700 700 700 325
70 365
Chapter 5 September 2016
2011 Edition Page 81
Shoulder Work w/ Minor Road Encroachment Diag. 300
J,<ROAD
WORK to
AHEAD '
•
Initial
Warning A •
Sign
•
(Optional) •
® I •
r
•
Protection Vehicle
w/TMA(both Optional
See Chapter 4 • Buffer
10'
minimum •
•
A ROAD
M NARROWS
(Optional)
B
1 1ROAD
WORK
\AHEAD
Initial
Warning
Sign
September 2016 Chapter 5