Loading...
Report ivq:c aoa2 00a-3 3 OFFICE COPY s 3 a s RECEIVED 1 aio MAR 21 loan Panasonic „ATY OF TIGARD INSTA LTA'ISir 1 ION INSTRUCTIONS Ventilating Fan Model No. FV-0811 RQ1 FV-131 5 RQ 1 ir Contents p 1 st GENERAL SAFETY INFORMATION 2-3 I DESCRIPTION 4 UNPACKING 4 SUPPLIED ACCESSORIES 4 • 5'v f 5 Y_Y FSF . N" • = DIMENSIONS 5 WIRING DIAGRAM 6 FEATURE 6 \[ • INSTALLATION (NEW CONSTRUCTION) 7-8 1I INSTALLATION (RETROFIT) 9 +` MAINTENANCE (CLEANING) 10 1:' :•. :..:;.- • x PRACTICAL GUIDE TO INSTALLATION 11 } • a,x _' ' SPECIFICATIONS 11 PRODUCT SERVICE 12 READ AND SAVE THESE INSTRUCTIONS Thank you for purchasing this Panasonic product. Please read these instructions carefully before attempting to install, operate or service the Panasonic product. Failure to comply with instructions could result in personal injury or property damage. Please explain to users how to operate and maintain the product after installation, and this booklet should be presented to users. Please retain this booklet for future reference. GENERAL SAFETY INFORMATION For Your Safety To reduce the risk of injury, loss of life, electric shock, fire, malfunction, and damage to equipment or property, always observe the following safety precautions. Explanation of symbol word panels The following symbol word panels are used to classify and describe the level of hazard, injury, and property damage caused when the denotation is disregarded and improper use is performed. AWARNING Denotes a potential hazard that could result in serious injury or death. ACA U T I O N Denotes a hazard that could result in minor injury. The following symbols are used to classify and describe the type of instructions to be observed. eThis symbol is used to alert users to a specific operating procedure that must be followed in order to operate the unit safely. 0 This symbol is used to alert users to a specific operating procedure that must not be performed. 0 This symbol is used to alert users not to disassemble the equipment. OThis symbol is used to alert users to make sure of grounding when using the equipment with the grounding terminal. AWARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING : 0 Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. ® Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. ® Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. ® Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities. ® When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 0 Ducted fans must always be vented to the outdoors. AIf this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter)- protected 2 branch circuit. GENERAL SAFETY INFORMATION CONTINUED A WARNING These models are UL listed for tub and shower enclosures.0 411 Do not disassemble the unit for reconstruction. It may cause fire or electric shock. ® A statement to the effect that when the product is to no longer be used, it must not be left in place but remove, to prevent it from possibly falling. 0 Ceiling joist must be subjected to static load more than five times the weight of the product. 0 Do not install with a method which is not approved in the instructions. Do not use these fans with any solid-state speed control device. Solid state controls may cause harmonic distortion which can cause motor humming noise. ® These products must be properly grounded. When one switch is connected with two or more products in parallel, the unit may not function. Therefore, parallel connection must not be allowed. ACAUTION O Do not install these ventilating fans where interior room Prohibited Excessive temperature may exceed 104°F(40°C). bending AMake sure that the electric service supply voltage is 0 W) AC 120 V, 60 Hz. Prohibited Successive ® Follow all local electrical and safety codes, as well as the bending National Electrical Code (NEC) and the Occupation Safety and Health Act (OSHA). 00 1 Squeezed Always disconnect the power source before working on® or near the fan, motor, light fixture or junction box. Prohibited duct Adaptor ® Protect the supply wiring from sharp edges, oil, grease,hot surfaces, chemicals or other objects. 0 IIIIII(!_ Prohibited 0 Do not kink the supply wiring. Bend close to duct 0 Provide make up air for proper ventilation. adaptor Fig. A For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. (cooking area) 0 Do not install the unit where ducts are configured \,_Don ins Do ide ide thi ts area above or —10-/as shown in Fig. A. , Not for use in cooking area. (Fig. B) \ `5/ \-'" ® The special-purpose or dedicated parts, such as mountingcooking / Floor fixtures, must be used if such parts are provided. equipment i( Fig. B 3 DESCRIPTION The Panasonic ventilating fan models are listed by UL under UL file No. E78414. The Panasonic ventilating fan models use a sirocco Blower driven by a capacitor motor. The motor is designed to have an extended service life with reduced energy consumption. It also incorporates a thermal-cutoff for safety. The grille covering the fan body is a spring-loaded, quick remove type. A damper for preventing air counterflow is provided. The blower uses a high-capacity sirocco fan developed to reduce the noise level. FV-0811 RQ1 has two speeds. "80" is low airflow and "110" is high airflow. FV-1315RQ1 has two speeds. "130" is low airflow and "150" is high airflow. UNPACKING Unpack and carefully remove the unit from carton. Refer to the supplied accessories list to verify that all parts are present. SUPPLIED ACCESSORIES Part name Appearance Quantity Part name Appearance Quantity Installation 1 Grille 1 instructions Warranty 1 Flex-Z Fast' sheet bracket (withs4�a�pping ! 1 Self-drilling 4 screw �} ST4.2X20) 4 DIMENSIONS FV 0811 RQ1 unit: inches (mm) 0 © © f 7/8(22.5) 1 12(37) 4 5/8(176) V e'T"''.- a, II 17-- 0 tiE m !I1 �i 2 I . b 013 330 No. Part name No. Part name ,L;I.. °o•� °Jo © ®1 Blade © Grille s s \ O2 Pick-A-Flow switch 07 Damper ® 1111 III' �3 Connector plate ® Flex-Z Fast bracket ® Junction box Fan body di 05 Adaptor Q' 010 1/4(260) 3 7/8 ill (100 • FV-1315RQ1 riMill © 3 7/8(22.5) r1 12(37) 4 5/8(116) .i li., ° m '4'ite-lr.�10 4 ���a oo'. e � m U i. O' °13 330 No. Part name No. Part name Lem°� �eJ` © �1 Blade ® Grille ®2 Pick-A-Flow switch ®7 Damper ® Connector plate ® Flex-Z Fast""bracket 113 ® Junction box 09 Fan body 0 ❑101/4(260) • 37/s(100 0 Adaptor 5 • WIRING DIAGRAM FV-0811 RQ 1 Fan body Junction box 1 Red Capacitor' White . White T • White - White Neutral 114°C Fuse in motor) Switch Motor Thermally t -(protected Power supply Black Black 110 CFM AC 120 V 60 Hz • Brown Black Black Live �� Yellow • - (114'C Fuse in motor) 80 CFM Thermally-protected Green Earth ground FV-1315RQ1 Fan body Junction box Red Capacitor' t White White T I White - White Neutral 114°C Fuse in motor) Switch ° Motor Thermally-protected Black Black 150 CFM Power supply I I • Brown Black Black Live AC 120 V 60 Hz \\ Yellow > (114°C Fuse in motor) 130 CFM Thermally-protected Green Earth ground FEATURE Pick-A-Flow Feature(only FV-0811 RQ1 ) CFM 1111 This product comes with Pick-A-Flow speed option. 80 4--►110 The Pick-A-Flow switch on the surface of the product Ills the option to choose 80-1 10 CFM. l 0 F. ii Air volume options Factory setting Pick-A-Flow w�l 80 CFM 110 CFM 80 CFM switch - 11 .� " , _1i�s Pick-A-Flow Feature(only FV-1315RQ1 ) CFM - This product comes with Pick-A-Flow speed option. 1304—►150 The Pick-A-Flow switch on the surface of the product 111. allows the option to choose 130-150 CFM. J m E0 Air volume options Factory setting Pick-A-Flow ��I7as -- 11 130 CFM 150 CFM 130 CFM switch - ��". 6 INSTALLATION (NEW CONSTRUCTION) The fan position between joists from 16"to 24" Machine screw Adaptor on center can be adjusted flexibly. (M4x6) APp+��,,I 11�i .. CAUTION nector�► 4 \� „ Please wear gloves to protect hands during ( 1- �' 1 the installation as follow. P Receptacle i Fan body ' 1. Disconnect plug connector from receptacle and \` 0.- Fig.1 remove adaptor from fan body by removing the machine screw (M4X6) before installation. (Fig.1) Joist / IMPORTANT: j" V •�‘V Please remove the tape, which protects the damper during shipping and installation, from ; — the duct adaptor as shown below. '. • �� , Bend down Ada for `��_,,i-' 4 tabs p Flex-Z Fast , 2 Tapping screws . �� F Damper bracket (ST4.2X20) Fig.2 � i Tape L--, '11--Joist 2. Bend down 4 tabs for positioning; install the �_� �, `rV Flex-Z FastT" bracket to joists by using the 2 y ,� pre-installed tapping screws. (Fig.2) 2 3. Adjust the length of Flex-Z FastTM bracket (5T4 2X )20 screws to fit the spacing between joists; fix the Fig.3 Flex-Z Fast' bracket with the other _ two pre-installed tapping screws. (Fig.3) Circular duct Mastic or ~' Conduit approved � foil tape 4. Remove junction box cover and secure conduit or j1 Adaptor stress relief to junction box knock-out hole. (Fig.4) rt )'-'' i , qi , Knock-out 1 fli'-- li ,,,7;_ \ 5. Install the circular exhaust duct and secure it with hole --- T-- _1 y\ clamps, or ties and seal it with mastic or approved Junction box k \ , foil tape. A 4 or 6 inch circular duct is needed to 4�'�1 \ cover connect to the relevant part of adaptor.(Fig.4) \ 2 Self-drilling / 6. Install the adaptor to Flex-Z Fast' bracket by Fig.4 using 2 self-drilling screws. (Fig.4) White 7. Refer to wiring diagram on page 6. Follow all —Black ®Green the local electrical safety codes as well as the a Wire nuts National Electrical Code (NEC). Using UL approved wire nuts, connect house power wires Conduit to ventilating fan wires. (Fig.5) Junction box Earth ground ` to green `.• ACAUTION Lt Wire nut �,f� is 1- Neutral to white 0 Mount junction box cover carefully so thatII lead wires are not pinched. Ire `� Ir` v Live to black Insure the junction box cover encloses all the i . / ( g fan) � Ventilatin wires and is completely flush before locking t. in place with the attached screw. Fig.5 7 INSTALLATION (NEW CONSTRUCTION) CONTINUED 8. Insert fan body and slide into adaptor assembly until the flange overlaps the Flex-Z Fast'bracket. Secure the fan body to Flex-Z Fast' bracket by ii`n-______ using 2 self-drilling screws, plug connector to Plug connector 4 mi `` `•�receptacle and secure the fan body to adaptor r� , ,<by using machine screw(M4X6). (Fig.6) "10 �I I .� ACAUTION Receptacle Mach" ine J� Secure the duct adaptor to the fan housingscrew 2 Self-drilling e p (M4X6) screws Fig.6 with the machine screw(M4X6) by and carefullyscrewingthe re-inserting adaptor to the housing. Please insure the screw is appropriately placed so it does not o IZ0-1 Ceiling Unit:inches(mm) strip the teeth nor come in contact with they o 1 •1 Flex-Z Fast' bracket. -01* /O v,, 9. Finish ceiling work. Ceiling hole should be l � , s - V ,L aligned with the inside edge of the flange. (Fig.7) �, .f�2 10. Select the air volume speed by adjusting the R\` switch. For FV-0811 RQ 1: Factory setting is "80" After finishing the ceiling job,fill gap betwee flange position; sliding "110" is high airflow position. and ceiling with caulk or other sealant to prevent air (Fig.8). For FV-1315RQ1: Factory setting is "130" leakage Fig.7 position; sliding "150" is high airflow position. (Fig.8) FV-0811 RQ 1: Mounting 71::t1;111:\r. �� /spring .��� ►s is;�• -Clip CFM q4 t1 ?�\�/y: < <,. 9®10 Switch u`�AP."� "` Y�-� k E9 y -kg*., Ceiling---� � �s '„y N. FV-1315RQ 1: trr/ Fig.9 11111% mr;-.::IA* 1A c,1It CFM '\*1L' 13®5Ui Switch C Slot Mounting spring Ceiling-, / Ot. - - i'll Ceiling Gloves Fig.8 i` ; 11. Take out the mounting springs from % clips. (Fig.9) Grille/ Fig.10 12. Insert one mounting spring into slot as shown in Fig.10. (If not,the grille may not be installed.) Ceiling. Mounting spring Grille—--""" Gloves 13. Insert the other mounting spring into the slot as shown and mount grille to fan body. (Fig.11) Fig.11 8 INSTALLATION (RETROFIT) Circular Unit:inches(mm) AWARNING �ddust Conduit L\i __ i, �` Joist Disconnect power source before working "\ ' ' 0 on unit. r -- _M ", 1`\ a .� 4Tapping s screws ��: N ,;" (5T4.2x20) .ed �� 1. Remove the existing fan and cut ceiling opening. Install the Flex-Z FastTM bracket to joists by using Ceiling(already existed) 4107i8(275) the 4 pre-installed tapping screws (ST4.2x20). Fig.12 Leave existing ductwork and wiring in place. (Fig.12) 2. Follow the step 1, 4, 5, 7 on page 7. (Before connect the circular exhaust duct to the — Circular duct Mastic or adaptor, pull down the circular duct from the �~' Conduit approved y ceiling.) jA foil tape Adaptor Knock-out L ' 3. Install the adaptor to Flex-Z Fast' bracket by holeIt using 2 self-drilling screws. (Fig.13) Junction box \. 4 cover \\. \ '\J 4. Secure the fan body to Flex-Z Fast" bracket by using 2 self-drilling screws, plug connector to 2 Self-drilling screws receptacle and secure the fan body to adaptor Fig.13 by using machine screw(M4X6). (Fig.14) A CAUTION Jost Secure the duct adaptor to the fan housing A with the machine screw(M4X6) by - re-inserting and carefully screwing the _ 117,-. <_ -f adaptor to the housing. Please insure the screw is appropriately placed so it does not -1 - = _� strip the teeth nor come in contact with theme Flex-Z Fast" bracket. Ceiling Machine screw(M4X6) � gg Flange 2 Self-drilling screws(Fix the lic"-------44 flange and Flex-Z Fast''bracket through the ceiling) 5. Follow the step 10 to 13 on page 8. Fig.14 9 MAINTENANCE (CLEANING) A WARNING (I) Disconnect power source before working on unit. A CAUTION ® Routine maintenance must be done every year. Please wear gloves during the cleaning work. Never use gasoline, benzene, thinner or any other such chemicals for cleaning the ventilating fan. Do not immerse motor in water when cleaning. Do not soak resin parts in water over 140 °F (60 °C). 1. Remove grille. (Squeeze mounting springs and Slot pull down carefully.)(Fig.15) Mounting =�� �� spring OIL_ _____—*. -V. Grille \ l i �' � r /"r, Gloves Fig.15 2. Wash and clean grille.(Don't put into hot water. Use non-abrasive kitchen detergent, I wipe dr II N Y with clean cloth.)(Fig.16) Y Fig.16 3.Remove dust and dirt from fan body using a vacuum cleaner. (Fig.17) 4.Using a cloth dampened with kitchen detergent j:_.. remove any dirt from fan body. Wipe dry with clean cloth. (Fig.17) Vacuum cleaner Gloves Fig.17 5. Reinstall grille. 10 PRACTICAL GUIDE TO INSTALLATION Properly insulate the area around the 4 inch or 6 inch roof jack,wall cap, FIg.18 fan to minimize building heat loss and or soffit vent with backdraft damper--__ gain. (Fig.18) Mechanically connect duct to termination Loose fill or batt insulation can be placed and seal with mastic or approved foil directly over the fan housing in the attic. faced tape Our fans and fan/light combination units 23 ft straight run before elbow, do not create excessive heat that is a In attic installation, common problem with recessed light caulk box to drywall fixtures or some competitor's fan/light — A short piece of flexible duct helps Insulation combination. Our efficient, cool-running alignment andabsobssound. motors and our LED lighting unit do not Use clamps plus mastic or approved Foil tape tightly covers all metal create enough ambient heat to be foil faced tape at all flex joints. duct joints.(Glue PVC joints) subjected to these limitations. The ducting from this fan to the outside of the building has a strong effect on the air flow, noise and energy use of the fan. Use the shortest, straightest duct routing possible for best performance, and avoid installing the fan with smaller ducts than recommended. Insulation around the ducts can reduce energy loss and inhibit mold growth. Fans installed with existing ducts may not achieve their rated air flow. SPECIFICATIONS Air Voltage Frequency Duct Air volume g Noise Speed Weight Model No. ( diameter at0.1"WG Power (W) direction (V) (Hz) (inches) (CFM) (sones) (rpm) lb.(kg) 80 <0.3 807 16.7 10.4 FV-0811RQ1 Exhaust 120 60 4 110 0.4 945 21.5 (4'7) 130 <0.3 646 25.3 11.7 FV-1315RQ1 Exhaust 120 60 6 (5.3) 150 0.3 690 27.7 HVI Certified performance based on HVI Procedures 915, 916, and 920. 11 PRODUCT SERVICE Warning Concerning Removal of Covers. The unit should be serviced by qualified technicians only. Your product is designed and manufactured to ensure a minimum of maintenance. Should your unit require service or parts, call Panasonic Call Center at 1-866-292-7299 (USA) Panasonic Corporation of North America Two Riverfront Plaza, Newark, NJ 07102 www.panasonic.com ©Panasonic Corporation 2018 Printed in China Issue date:05/2018 12 P0518-0 08RQ10420 OFFICE COPY RECEIVED mAR 2 12022 SEPTEMBER 2010 _ ® Fantech ciiYOFT1GA• � ��? Ilr nlrvh �Ilrl THE INDUSTRY STANDARD FOR !NLWE DUCT FANS JUST GOT BETTER! The company that invented the circular duct fan more �;�. ,,� . itt: c(pus than thirty years ago, now introduces new improved � � inline fans that are virtually airtight. New production processes eliminate manufacturing variances to ensure tight tolerances for optimal performance of every fan. " Galvanized steel housings meet code requirements for bothENEMY STAR �Ix; residential and commercial applications. High quality ebm-papst Look for The rnr;o. motors ensure longlife and dependable performance. air: ;bar oo book I,- Simplified Installation: The FG Series features new longer duct connections for easier installation. Fans are prewired and include bracket for mor:nting to wall or ceiling. Straight-through airflow allows fans to be installed at any • Performance • Air Tightness angle at any point along the ductwork. • Efficiency • Ease of HVI CERTIFIED • Reliability Installation tit Uibradon IsotaLng Clamps Wia Suspznsion _ / •e �"""" .., r • va. rGC SERIES Duo Fantech Wine BELt Too HARD WORKING. LONG LASTING. HERE'S WHY: • Airtight galvanized steel housing—perfect for commercial 13 MODELS TO CHOOSE FROM: code applications • 4"to 12"duct diameters • Powered by ebm-papst external rotor motorized impeller • 135 to 940 CFM for excellent heat dissipation, even at low RPM • o • Backward curved impeller 1001n speed controllable • Permanently lubricated • Rated for airstream temperatures up to 140° F sealed ball bearings • Rated for outdoor use for maintenance- I • Five-year factory warranty free operation t • UL Listed; CSA Certified • Automatic reset thermal overload I -; protection Fantech external rotor motor ww,ni.fautech net a FROM RESIDENTIAL TO COMMERCIAL N. s' • ,.a•' tu 4 ' " ' saaa� '� i° sa°inw - ' ✓ s y : t x FE _ ° t s . . ttitt'lIs l x x i a ;� Ia rt a 5i3e t fittl ; "b i ' .. tt,tItit S ryt 1 dT � I I t }{ S .?r Itaia ik l:a { r y41� " x at tt t s t s5 `� .. r 0{15t r3&, Mx Ili ;Atli {$ a t .,.o„P- FG 10 e:"t ""t''. it DIMENSIONAL DATA r-33/3" AIR PERFORMANCE GRAPHS 3.50 liii hithh.1111 411°1 1.50 are mo LMLPSeaIlAeratirysam • A 1 GG \ a�mcm ac AISA FG 6 �`,. cwm,m�aac \ n�Nna ui�mc tr ammah wlm sa 0.50 sucined Pato ca FG4 � D C 0.00 0 100 200 300 400 500 600 700 800 900 1000 Flow Rato(CFMI Model to C D E F liethe_ 3.50 FG 4 4 83/4 _ 61/1 1 1 HVI FG 4xk 4 93/4 615/16 1 1 CERTIFIED 3,00 FG5 5 83/4 _ _ 51/2 1 7/s i 2sa FG 5xi 5 93/4 515/is 1 1 C UL US = FG 6 6 113/8 6 1 1 z.fio FG 6m/F6 6m 6 131/e 65/8 1 1 x FG 12xr FG 8 8 133/s 6 1 Va 11/e d 1.50 FG 6m Fc eu FG 1oxE 5..,,,FG 8xk 8 133/e 6 11/8 11/a 5 190 FG 10 10 133/8 6/Is PVa 1 FG Rx;\ FG 10x6 10 13318 57/a 11la _1 9 50 FG 12 12 16 81/4 11/I6 13/16 000 FG 4. FG 5w FG 12xt 12 16 81/4 11/16 13/it 837321= 0 100 200 300 400 500 600 700 800 900 1000 ---- - ---------- ------- - - Look to[me Erere� Flow Rate(CFMI All dimensions in inches.'Duct connections are Ye"smaller than duct size. St.eared Models In Peammance PERFORMANCE DATA Data rt Fan Energy Rated Max. Static Ple:anrc m mchi5W.3. Max. Duct Model Star RPM Voltage Watts Amps 0" 0.1" 0.2" 0.4" 0.6" 0.8" 1.0" 1.25" 1.5" 2.0" 2.5" Ps Dia. FG 4 ✓ 3000 120 20 0.19 135 123 110 83 55 25 - - - - - 0.94 4" FG 4xi. - 2750 120 71 0.66 170 160 150 134 119 103 86 63 40 - - 1.98 4" FG 5 ✓ 3000 120 20 0.19 156 143 130 99 66 33 - - - - - 0.99 5" FG 5xt - 2700 120 73 0.68 220 205 190 160 135 112 91 66 41 - - 1.89 5" FG 6 ✓ 2700 120 72 0.68 303 287 270 232 196 164 134 97 58 - - 1.88 6" FG 6m 1.0 2350 120 120 1.02 418 394 370 317 268 224 186 144 101 - - 2.10 6" FG fixt V 2900 120 153 1.48 483 466 450 409 369 329 289 243 201 103 - 2.41 6" FG 8 V 2550 120 119 1.14 461 435 410 351 295 243 191 143 97 - - 2.11 8" FG 8xt ✓ 2950 120 142 1.45 502 486 470 428 388 351 313 266 218 100 - 2.40 8" FG 10 V 3000 120 138 1.43 513 497 480 444 407 366 324 269 216 89 - 2.36 10" FG 10xr V 3100 120 196 1.96 589 574 560 531 503 472 441 400 355 257 137 3.02 10" FG 12 ✓ 2600 120 181 1.87 741 711 680 601 515 434 363 290 236 146 72 2.99 12" FG 12xt V 2900 120 301 3.01 940 910 880 819 746 670 596 505 425 259 80 2.74 12" Performance certified is for installation type D-Ducted inlet Ducted outlet Speed(RPM)shown is nominal.Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances(accessories) Fa n to e h United States 10048lndustrial Blvd.•Lenexa KS 66215•1.800.717.1762•www fantech net Item K.450459 Canada 50 Kanalflakt Way•Bouctouche,NB EAR 3M5•1.800.565.3548•www.fantech.net Rev Date:111011 Fantech,reserves the right to modify,at any time and without notice,any or all of its products'features,designs,components and specifications to maintain their technological leadership position. : fantech® OFFICE COPY HEUER/Et a systemair company PIAR ? 11011 CITY OF I IGARD 3UILDING DIVISION DBF 4XL Duct Booster Fan 4"duct booster fan,5ft cord w/plug, 120V, 1- Item#:95901 Variant:120V 1-60Hz ■11 C US (N®V1�J DBF 4XL is a duct booster fan designed for boosting air on in applications such as extended ductwork,crawlspace ventilation,and dryer exhaust.The product is equipped with a 5 feet cord,pressure- sensing switch that activates the fan once positive pressure is sensed in the duct line.The switch shuts the fan off when the pressure differential falls below the activation level. •Suitable for 4"ductwork , •Metal leak-proof housing � ~ %. r9` •Pressure switch,5 ft cord for 120V/1- ' •Duct runs up to 130 linear feet The DBF 4XL features a galvanized metal housing,pressure-sensing switch and a 5 feet cord for 120V/1-connection.Suitable for 4" ductwork. Performance certified by HVI;Conforms to UL Standard 507. Technical parameters nan Voltage(nominal) 120 Frequency 60 Phase(s) 1- Input power 65 .. Input current 0.54 Impeller speed 2,175 :, Air flow max 188 Temperature of transported air max 140 Item name:DBF 4XL Duct Booster Fan I Product link.https://shop.fantech.neVen-US/productPermalink?p=1115991 Item#:95901 !Variant:120V 1-6DHz Document type:Product card Created on:2022-01-31 Generated by Fantech Online Catalogue!Language:English Page 1 of 6 Performance Performance curve wg. • 1.60.6 0.4 DI 1 t I I 0 10 20 30 40 50 60 70 60 90 100 110 120 13D 140 150 160 elm Hydraulic data Required air flow - Required static pressure - Working air flow Working static pressure - Air density 0.075 lb/ft3 Power Fan control-RPM - Current - Airflow efficiency - Control voltage Supply voltage - Item name:DBF 4XL Duct Booster Fan I Product link:https://shop.fantech.net/en-US/productPermalink?p=1115991 Item#:95901 Variant:120V 1-60Hz 1 Document type.Product card I Created on:2022-01-31• Generated by:Fantech Online Catalogue 1 Language:English Page 3 of 6 Performances Dimensions D A ca a Qo Q )11 4 ►I A Item name:DBF 4XL Duct Booster Fan I Product link:https://shop.fantech.net/en-US/productPermalink?p=1115991 Item#:95901 I Variant:120V 1-60Hz I Document type:Product card Created on:2022-01-31 Generated by:Fantech Online Catalogue Language:English Page 4 of 6 Y Y Wiring E A To 40 BTo H a ' r-- 'BOP c J Position A B ' Des,ri nlioa. Pov;er Item name:DBF 4XL Duct Booster Fan I Product link.https:!/shop.fantech.net/en-US/productPermalink?p=1115991 Item#:95901 Variant:120V 1-60Hz Document type:Product card I Created on:2022-01-31 Generated by:Fantech Online Catalogue I Language:English Page 5 of 6