Loading...
Report f `S 2 n a2-- 000 '1319 D"rk°''`�`OFFICE COPY' OFFICE COPY RED HAWK FIRE PROTECTION, LLC 3801 Fruit Valley Rd. Vancouver, WA 98660 (360) 984-3712 RECEIVED FEB 12022 GUY OF TIGARD lupLDlnlr, nlvnslo0 ))), •fifrei6 Xplaire FIRE SPRINKLER EQUIPMENT SUBMITTAL FOR PROVIDENCE CREDENA MAIL ORDER PHARMACY T.I. PORTLAND, OR • RHFP JOB NO. 240295 TABLE OF CONTENTS RED HAWK 1J1 FIRE PROTECTION, LLC Section 1 - Pipe and Fittings Description Comments schedule 40 Blk. Pipe Victaulic 920 Threaded&Grooved Mecanical Tee Section 2 - Hangers and Sway Bracing Description Comments Erico Hanger Ring Sammy_Sidewinders Section 5 - Fire Sprinklers Description Comments Tyco TY-B Standard Response Upright/Pendent_K=5.6 Tyco DS-1 Dry Pendent_K=5.6 Comparative Specification Data Specification A53 NPS 1/0-26 STD,XS and XXS,ANSI Schedules 10 through 160 110 Covers Seamless and Welded,Black and hot-dipped galvanized nominal(average)wall pipe for coiling,bending,flanging and Scope other special purposes and is suitable for welding.Continuous-Welded pipe is not intended for flanging.Purpose for which pipe is intended should be stated on the order Kinds of Steel Permitted Open-hearth for Pipe Material Basic-Oxygen Electric-Furnace Hot-Dipped Galvanized Sets standards for coating of pipe with zinc inside and outside by the hot-dipped process.Weight of coaling must not average less than 1.5 oz per square foot and not less than 1.6 oz per sq foot Permissible Variations in The minimum wall thickness at any point shall not be more than 12.5%under the normal wall thickness specified Wall Thickness CMax% MnMax% PMax% SMax% Seamless or ERW Chemical Requirements Grade A 0.25 0.95 0.05 0.06 Grade B 0.30 1.20 0.05 0.06 Continuous Weld - - 0.06 0.06 Seamless and Electric resistance-welded Tensile Requirements Grade A Grade B Tensile Strength,Min psi 45,000 48,000 60,000 Yield Strength,Min psi 25,000 30,000 35,000 Hydrostatic Testing Hydrostatic inspection test procedures for plain end and threaded and coupled pipe are specified.Hydrostatic pressure shall be maintained for not less than 5 seconds for all sizes of seamless and electric resistance weld pipe Permissible Variations in Plus or Minus 10% Weight per Foot Outside Diameter at any point shall not vary from standard specified more than- Permissible Variations in For NPS 1 1/2 and Smaller Sizes For NPS 2 and Larger Sizes Outside Diameter 1/64"over 1/32"under 1%over 1%under Tensile Test-Transverse required on ERW for NPS 8 and larger Banding Test(Cold)-STD and XS-NPS 2 and under XXS-NPS 1 1/4 and under ilkMechanical Tests Dearee of Bend Diameter of Mandrel Specified For Normal A53 Uses 90 12 x nom dia of pipe For Close Coiling 180 8 x nom dia of pipe Flattening Test-NPS 2 and larger STD and XS.(Not required for XXS Pipe) Seamless and Electric-Resistance-Welded Bending,flattening,tensile on one length of pipe from each lot of 500 lengths or less of a size Number of Tests Required Continuous-Weld-Bending,Flattening,Tensile NPS 1 1/2 or smaller NPS 2&Lamer one/25 long one/50 tons Standard Weight Single Random-15'-22'may be jointers.If plain ends 5%may be 12'-16' Double Random-Shortest Length 22',minimum average for order 35' Lengths Extra Strong&Double Extra Strong Single Random-12'-22'.5%may be 6'-12' Double Random-(XS and lighter)-Shortest Length 22".Minimum average for order 35' Lengths longer than since random with wall thinness heaver than XS subject to negotiation Rolled,Stamped,or Stenciled(Mfgr's option) Required Markings on Name or brand of manufacturer Each Length (On tags attached to each Kind of pipe that is,Continuous Welded,Electric-Resistance-Welded A,Electric-Resistance-Weeded B, Seamless A;or bundle in case of bundled Seamless B:XS for double extra strong pipe) ASTM A 53 Length of Pipe Couplings-Applied handling tight.Couplings 2"and smaller,straight tapped other sizes type Thread Protection-Applied to pipe 4"and larger General Installation End Finish(Unless otherwise specified)-STD or XS or wall thickness less than 0.500 in.(Excluding XXS);plain end beveled.All XXS and wall thicknesses over 0.500 in.Plain end square cut. S NOTE: This information is from ASTM Standards. Please refer to the specific Standard or Specification for complete details Comparative Specification Data Specification A135 NPS 1/4-30",Schedules 10,40 and XL THD Lightwall Scope Covers two grades of electric-resistance welded steel pipe.Grade A is adapted for flanging and bending and is suitable for welding.Purpose for which pipe is intended should be stated on order Kinds of Steel Permitted Open-hearth for Pipe Material Basic-Oxygen Electric-Furnace Permissible Variations in The minimum wall thickness at any point shall not be more than 12.5%under the normal wall thickness specified.Threadable, Wall Thickness lightwall(XL)must meet manufacturers minimums. C Max% Mn Max% P Max% S Max% Chemical Requirements Grade A 0.25 0.95 0.05 0.06 Grade B 0.30 1.20 0.05 0.06 Grade A Grade B Tensile Strength,Min psi 48,000 60,000 Yield Strength,Min psi 30,000 35,000 Hydrostatic inspection test procedures for plain end and threaded are specified.Hydrostatic pressure shall be maintained for not Hydrostatic Testing less than 5 seconds for all sizes of electric resistance weld pipe.Non-Destructive electric test should be in accordance with practices E213,method E273 or proactive E213 Permissible Variations in Plus or Minus 10%Schedule 10 Weight per Foot Plus 10%minus 3 1/2%Schedule 40 Permissible Variations in Plus or Minus 1% Outside Diameter Mechanical Tests Tensile Test-Transverse returned on pipe NPS 8 and larger Specified Flattening Test-Three steps required with weld located 8"or 90*from the line of direction of force required Number of Tests Required Flattening and tensile on one length of pipe from each lot of 400 lengths or less of a style Lengths Pipe shall be furnished in 38"with a minimum of 20 ft.Pipe furnished to schedule 10 shall be in a specified length between 15 and 22 ft. Required Markings on Rolled,Stamped,or Stenciled(Mfgr's option) Each Length Name or brand of manufacturer (On tags attached to each Kind of pipe that is,Electric-Resistance-Welded A,Electric-Welded B,same schedule wall thickness,schedule 10 or 40,NL bundle in case of bundled ASTM A135 pipe) Length of Pipe General Information End Finish may be plain end beveled or plain end square cut _ • NOTE: This information is from ASTM Standards. Please refer to the specific Standard or Specification for complete details Comparative Specification Data Specification A795 NPS 1/2-10"Schedule 10 and Schedule 40 1111 Covers Seamless and welded,black and hot-dipped galvanized nominal wall pipe for coiling,bending,flanging and is suitable COpa for welding.Pipe ordered for this specification is intended to be used in fire protection systems Kinds of Steel Permitted Open-hearth for Pipe Material Basic-Oxygen Electric-Furnace Sets standards for coating of pipe with zinc inside and outside by the hot-dipped process.Weight of coating must not average Hot-Dipped Galvanized less than 1.5 oz per square foot and not less than 1.6 oz per sq foot Permissible Variations in The minimum wall thickness at any point shall not be more than 12.5%under the normal wall thickness. Wall Thickness C Max°/Q MnMax% PMax% SMax% Seamless or ERW Chemical Requirements Grade A 0.25 0.95 0.05 0.06 Grade B 0.30 1.20 0.05 0.06 Continuous Weld - - 0.06 0.06 Hydrostatic inspection test procedures for plain end and threaded are specified. Hydrostatic pressure shall be maintained for not Hydrostatic Testing less than 5 seconds for all sizes of seamless and electric resistance weld pipe.Non destructive electric test in accordance with practices E213 or E309 Permissible Variations in Plus or Minus 5% Weight per Foot Permissible Variations in Outside Diameter at any point shall not vary from standard specified more than- Outside Diameter For NPS 1 1/2 and Smaller Sizes For NIPS 2 and Larger Sizes 1/64"over 1/32"under 1%over 1%under Number of Tests Flattening-Tests are to be performed on electric-resistance welded pipe,and furnace welded pipe. Required Lengths Unless specified,pipe shall be furnished on single random lengths of 16 to 22 ft. Rolled,Stamped,or Stenciled(Mfgr's option) Required Markings on Name or brand of manufacturer ch Length Electric-Resistance-Welded A,Electric-Resistance-Weeded B,Seamless A n tags attached to each bundle in case of bundled Seamless B,Grade A or B for type E or S pipe,wall thickness schedule ASTM A795,the letters NHII Not hydrostatically tested Pipe) Length of Pipe General Installation End finish may be plain end beveled or plain end square cut • NOTE: This information is from ASTM Standards. Please refer to the specific Standard or Specification for complete details CARBONS - - .• -:•r *wrirmill Mechanical-1F' Bolted Branch Outlets 0 m Q (UdS) LPCB SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLES 920 AND 920N • Victaulic Mechanical-To Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a "holefinder"locating collar which secures the outlet in position permanently.A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size,with the same or differing branch size connections. NOTE: Style 920 and Style 920N 411 housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded STYLES 920 AND 920N STYLE 920 CROSS outlet.Specify choice on order. Units are supplied painted with plated bolts.Galvanized hous- PATENTED ings are available,supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule 10 and 40 carbon steel pipe.They may also be used on high density polyethylene or poly- butylene(HDPE)pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 90°angle when permanently attached to the pipeline surface. Additionally,the Vic-Tap II®hole cutting tool,which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit.See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating:Ductile iron conforming to ASTM A-536,grade 65-45-12,with orange enamel coating. Ductile iron conforming to ASTM A-395,grade 65-45-15, is available upon special request. • Optional: Hot dipped galvanized Gasket: (Specify choice*) • Grade"E" EPDM EPDM (Green color code).Temperature range—30°F to+230°F/-34°C to+110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids,oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold+86°F/+30°C and hot+180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade"T"nitrite Nitrile(Orange color code).Temperature range—20°F to+180°F/-29°C to+82°C. Recommended for petroleum products,air with oil vapors,vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over+150°F/+66°C or for hot dry air over+140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV M CARBON STEEL PIPE- HOLE CUT PRODUCTS 11.V IIG 1111e1rrhan ral-T® Belted Branch Outlets STYLES 920 AND 920N • DIMENSIONS Style I Max.Work App,o. Size No. Pressure@ Dimensions Weight Each Run x branch " V n IS le Female Nominal Size r T-^ Thd W Y Z Thd. Grv. Y .--Z->. Inches orY'psi +0.13 Inches Inches Inches Inches Inches Inches Lbs. Lbs. min 920N kPa -0.00 min min min mm min min kg kg r er'- 1 2 x 1/2(a)° 920N 500 1.50 2.00 2.53 - 1.61 5.35 2.75 3.1 V 50 15 3450 38.1 51 64 - 41 136 70 /i 1.5 - n �'� ur' 3/4(a)° 920N 500 1.50 1.97 2.53 1.61 5.35 2.75 3.1 M,_ 4 W 20 3450 38.1 50 64 - 41 136 70 1.5 1(a)En 500 1.50 1.85 2.53 1.61 5.35 2.75 3.0 25 920N 3450 38.1 47 64 41 136 70 1.4 114(8)to 920N 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2 GROOVED OUTLET 32 3450 44.5 52 70 76 41 136 76 1.7 1.5 11/2(a)to 920N 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 3450 44.5 52 70 79 41 136 83 1.7 1.5 c Y > A z 21 IS(a)40 500 1.50 2.21 2.74 - 1.82 5.64 2.75 3.0 _ 65 x 15 920N 3450 38.1 56 70 46 143 70 1.4 t PINW �',(a)§a 920N 500 1.50 2.18 2.74 - 1.82 5.64 2.75 3.0 _ V III rGr T 20 3450 38.1 55 70 46 143 70 1.4 1 1(a)§° 500 1.50 2.06 2.74 _ 1.82 5.64 2.75 2.9= � ,��'. 25 920N 3450 38.1 52 70 46 143 70 1.4 I Pk t(a)° g20N 500 1.75 2.30 3.00 3.25 1.82 6.29 3.00 3.5 3.2 1-1 32 3450 44.5 58 76 83 46 160 76 1.7 1.5 FEMALE THREADED OUTLET 1 1/2t(a)a 920N 500 2.00 2.28 3.00 3.25 1.82 6.26 3.25 3.6 3.3 40 3450 50.8 58 76 83 46 159 83 1.7 1.6 Y:(a) 300 150 2.22 2.75 _ 2.25 6.46 3.18 3.9 - 76.1 x 15 920N 2065 38.1 56 70 - 57 164 81 1.8 • Provides a direct branch connection at Y(a) 920N 300 150 2.19 2.75 2.25 6.46 3.18 3.9 any location where a hole can be cut 20 2065 38.1 56 70 - 57 164 81 1.8 in the pipe 1(a) 920N 300 1.50 2.07 2.75 _ 225 6.46 3.18 3.8 - 25 2065 38.1 53 70 57 164 81 1.7 11, • A pressure responsive gasket provides 11/4(a)0 920N 500 1.75 2.30 3.00 3.31 1.92 6.29 3.c0 3.5 3.2 the seal 32 3450 44.5 58 76 84 49 160 76 1.6 1.5 1 Yi(a)0 920N 500 2.00 2.28 3,00 3.31 1.92 6.29 3.25 3.5 3.3 • Request Publication 11.03 for 40 3450 50.8 58 76 84 49 160 83 1.6 1.5 Mechanical-T cross assemblies 3 'k(a)° 500 1.50 2.52 3.05 _ 2.28 6.15 2.75 3.4 _ 80 x 15 920N 3450 38.1 64 ' 78 58 156 70 1.6 • Pressure rated up to 500 psi/3450kPa /(a)° 920N 500 1.50 2.49 3.05 2.28 6.15 2.75 34 on steel pipe; also available for use 20 3450 38.1 63 78 - 58 156 70. 1.6 with HDPE pipe 1(a) 920N 500 1.50 2.38 3.06 2.28 6.15 2.75 3.3 25 3450 38.1 61 78 58 156 70 1.6 • Sizes from 2 x 1/2"/50 x 15mm 1'Aa(a)to g20N 500 1.75 2.55 3.25 3.56 2.28 6.15 300 3.8 3.7 through 8 x 4"/200 x 100mm 32(b) 3450 44.5 65 83 90 58 156 76 1.8 1.8 1'h(a)ta,, 920N 500 2.00 2.78 3.50 3.56 2.28 6.15 3.25 4.1 3.8 40(b) 3450 50.8 71 89 90 58 156 83 1.9 1.8 2(a)a 920N 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.9 4.6 50 3450 63.5 70 89 90 58 172 99 2.3 2.1 31/2 2 500 2.50 3.00 3.75 2.44 6.72 3.88 3.8 90 x 50 920N 3450 63.5 76 95 62 171 99 1.8 IMPORTANT NOTES: TABLE CONTINUED ON PG.3 _ Style 920 and Style 920N housings cannot be '*Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). mated to one another t Available with grooved or female threaded outlet.Specify choice on order. to achieve cross connections. t Center of run to end of fitting. It Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. (b)For 76.1 mm threaded outlet,specify 21/2"BSPT clearly on order. §Vds approved for fire protection services a LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. • www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. iCtauII :' 11.02 2 CARBON STEEL PIPE- HOLE CUT PRODUCTS 1 1•UL MprhaniiraI-T® Bolted Branch Out!P STYLES 920 AND 920N • __ DIMENSIONS Style Max.Work Approx. Size No. Pressure@ Dimensions Weight Each h nal.ranc Size. T*- W S Inches or psi +013 Inches inches')nches Inches Inches Inch-@s "Bs."" It"' Y s A Z e mm 920N kPa -0.00 mm mm mm mm mm mm kg _ �1 TABLE CONTINUED FROM PAGE 2 Ak 4 r; V �` 4 x h(a) 920N 500 L50 3.03 3.56 - 2.69 701 2.75 3.7 - tit ' �-~ Iasi 1 `1 Pi 1� 100 _15 3450 38.1 77 90 68 178 70 1.8 sA(a)❑ 500 1.50 3.00 3.56 2.69 7.01 2 75 3.7 - I�- -- } dO II 20 920N 3450 381 76 90 68 178 70 1.8 1 � y L 1(a)0 920N 500 1.50 2.88 3.56 _ 2.69 701 275 3.6 _ 25 3450 38.1 73 90 68 178 70 1.8 GROOVED OUTLET I'/a(a)to 920N 500 1.75 3.08 3.78 4.00 2.69 7.01 300 4.0 3.6 32(b) 3450 44.5 78 96 102 68 178 76 1.9 1.8 1'h(a)to 920N 500 2.00 3.28 4.00 4.00 2.69 7.01 3.25 4.2 3.9 4----Y 1 r z sl 40(b) 3450 508 83 102 102 68 178 83 20. 1.9 Pig + 2(a)to 920N 500 2.50 3.25 4.00 4.00 2.69 7.01 3.88 5.0 4.6 50 3450 63.5 83 102 102 68 178 99 2.3 2.1 1 Ag .11111111111P1110 •"-"" tal• 7 .-7(Fill 21/2(a)t 920 500 2.75 2.88 4.00 4.00 2.69 7.34 4.63 5.8 5.0 65 3450 69.9 73 102 102 68 186 118 2.6 2.3 - - ` 500 2.75 2.88 _ 400 2.69 7.34 463 _ 64 76.1 mm: 920 y j I -I 3450 69.9 73 102 68 186 118 2.9 1 L 3(a)t 500 3.50 3.31 4.50 4.12 2.69 7.73 512 84 6.4 80 920 3450 88.9 84 114 105 68 196 130 3.8 2.9 FEMALE THREADED OUTLET PA(alti 500 1.75 3.08 3.78 - 2.63 7.64 3.05 50 - 108.0 x 32 920N 3450 44.5 78 96 67 194 78 23 1 h(a)o 920N 500 2.00 3.28 4.00 - 2.63 7.64 3.25 5 0 • Provides a direct branch connection at 40 3450 50.8 83 102 67 194 83 2.3 any location where a hole can be cut 2(a) 9zoN 500 2.50 3.25 4.00 2,63 7.64 400 4.0 - III In the pipe 50 3450 63.5 83 102 - 67 194 102 19 76.1 mm 920 500 2?5 2.88 4.00 4.00 2.63 7.64 4.29 8.0 7.8 • A pressure responsive gasket provides 3450 69.9 73 102 102 67 194 109 36 3.5 the seal 3(a) 920 500 3.50 3.31 4.50 4.50 2.63 7.63 4.88 6.8 6.5 80 3450 88.9 84 114 114 67 194 124 3.1 3.0 • Request Publication 11.03 for 5 1'h(a)t 500 2.00 4.03 475 4.75 3.16 9.70 3.69 74 7.6 Mechanical-T cross assemblies 125 x 40 920 3450 50.8 102 121 121 80 246 94 3.4 3.4 2(a)t 500 2.50 4,00 475 4.75 3.16 9.70 438 8.2 80 • Pressure rated up to 500 psi/3450kPa 50 920 3450 63.5 102 121 121 80 246 , 111 3.7 3.6 on steel pipe; also available for use 21/2(a)t 920 500 2.75 3.63 475 4.75 3.16 9.70 463 8.3 7.9 with HDPE pipe 65 3450 69.9 92 121 121 80 246 118 3.8 3.6 76.1 mm• 920 500 2.75 375 - 475 3.16 9.70 4.63 _ 8.0 • Sizes from 2 x 'W/50 x 15mm 3450 69.9 95 121 80 246 118 36 through 8 x 47200 x 100mm 3(a)t I 920 500 3.50 3.81 500 4.63 3.16 9.70 5.31 8.4 8.8 80 3450 88.9 97 127 118 80 246 135 3.8 4.0 2 500 2.50 3.75 4.50 - 3.17 8.00 3.88 8.0 _ 133.0 x 50 920N 3450 63.595 114 81 203 99 3.6 3 920 500 3.50 3.81 5.00 _ 3.00 9.46 5.31 8 0 - 80 3450 88.9 97 127 76 240 135 3.6 TABLE CONTINUED ON PG.4 IMPORTANT NOTES: "Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). Style 920 and Style 920N housings cannot be t Available with grooved or female threaded outlet.Specify choice on order. mated to one another # Center of run to end of fitting. to achieve cross connections. # Female threaded outlets are available to NPT and BSPT specifications. eti See page 7 for Fire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. (b)For 76.1 mm threaded outlet,specify 21/2"BSPT clearly on order. §Vds approved for fire protection services 0 LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.W 2012 VICTAULIC COMPANY ALL RIGHTS RESERVED. til�tau1I C RFV M CARBON STEEL PIPE- HOLE CUT PRODUCTS 11.V L Mechanir..al-T° Bolted Branch ()utletc STYLES 920 AND 920N 411, DIMENSIONS Style Max.Work Approx. Size No. Pressure@ Dimensions Weight Each Hole e Diameter T`" �'W • Z �Y inches or "psi +0.13 Inches Inches ‘Inches Inches Inches Inches LM. Lhs. x Y r 14 Z---A. mm 920N P. -0.00 mm mm mm mm mm mm kg kg NM } TABLE CONTINUED FROM PAGE 3 �� IV 1397 x 1 t 920N 500 2.00 3.78 4.50 3.30 8.23 3.25 7.0 nit '.......•'.......• rift t ril 40 3450 50.8 96 114 84 209 83 3.2 _ M 0 4 2 t 920N 500 2.50 • 3.75 4.50 3.30 8.23 3.88 9.0 50 3450 635 95 114 84 209 99 4.1 6 x 1 1/4(a) 920N 500 1.75 4.43 5.13 5.13 3.79 9.15 3.25 5.1 4.8 150 32(b) 3450 44.5 112 130 130 . 96 232 83 2,3 2.2 GROOVED OUTLET 11 (a)tra 920N 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.1 40(b) 3450 50.8 112 130 130 96 232 83 2.4 2.3 2(a)to 020N 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6 < Y la-z 0 50 3450 63.5 111 130 130 96 232 99 2.7 2.5 1 I 2 V 020 500 2.75 4.01 5.13 512 3.69 10.51 4.63 8.3 7.6 +r+ 65 3450 69.9 110 130 130 94 267 118 3.8 3.4 V �-" T 500 2.75 4.15 _ 5.21 3.69 10.51 4.63 _ 8.4 at rn T ur 76.1 mm r� 920 3450 69.9 105 132 94 267 118 3.8 i p>- 14-t 3(a)t 920 500 3.50 4.31 5.50 5.13 3.69 10.51 5.31 9.9 8.4 y ( 80 3450 88.9 110 140 130 94 267 135 4.5 3.8 1--1 4(a)to 500 4.50 3.81 5.75 5.38 3.69 10.51 6.25 10.1 10.1 100 920 3450 114.3 97 146 137 94 267 159 4.6 4.6 FEMALE THREADED OUTLET 1 h(a) 500 2.00 4.41 5.13 3.63 • 9.40 3.25 7.8 - 159.0 x 40 920N 3450 50.8 112 130 92 239 83 3.5 2(a) 500 2.50 4.38 5.13 _ 3.63 9.40 3.88 8.0 - • Provides a direct branch connection at 50 920N 3450 63.5 111 130 92 239 99 3.6 any location where a hole can be cut 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 76.1 mm 920 in the pipe 3450 69.9 111 140 130 92 239 118 4.3 4.3 3 500 3.50 4.31 5.50 5.13 3.63 9.40 5.31 8.1 14.0 • j • A pressure responsive gasket provides 80 920 3450 88.9 110 140 130 92 239 135 3.7 6.4 the seal 108.0mm 920 500 4.50 4.45 5.38 3.63 9.40 6.12 10.0 3450 114.3 113 137 92 239 155 4.5 • Request Publication 11.03 for 4 500 4.50 3.81 5.75 3.63 9.40 6.25 18.0 Mechanical-T cross assemblies 100 920 3450 114.3 96.80 146 - 92 239 159 8.2 TABLE CONTINUED ON PG.5 • Pressure rated up to 500 psi/3450 kPa •+Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). on steel pipe; also available for use t Available with grooved or female threaded outlet.Specify choice on order. with HDPE pipe # Center of run to end of fitting. • Sizes from 2 x 1 750 x 15mm # Female threaded outlets are available to NPT and BSPT specifications. through 8 x 47200 x 100 mm @ See page 7 for Fire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. (b)For 76.1 mm threaded outlet,specify 2/'BSPT clearly on order. §Vds approved for fire protection services ❑LPCB approved for fire protection services IMPORTANT NOTES: 0 Approved for use in China by Tianjin Approvals Company. Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. • www.victaulic.com _ VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. rCtalJ l rC: 11.02 4 CARBON STEEL PIPE-HOLE CUT PRODUCTS 1 I.•UL Mechanical-T® Bolted Bran( STYLES 920 AND 920N • DIMENSIONS Style Max.Work A aura c. Size No. Pressure@ Dimensions Weight Each y un x Branch V-?# V i Female ,Nominal Size 920 ,-T" Thd. Gee. W Y Z Thd. Grv. Inches or psi `F0..1 Inches Inches Inches Inches Inches Inches Lbs. Lbs. Y r <--Z-> mm 920N kPa -0.00 mm mm mm mm mm mm kg kg _ TABLE CONTINUED FROM PAGE 4 /�� 1 500 1.50 3.88 4.56 _ 3.79 9.34 2.75 8.0 V.1. a 165.1 x 920N to0 uu I(!ii 25 3450 38.1 99 113 97 237 2 3.6 ,� 1 r/as( 920N 500 1.75 4.43 5.13 _ 3.79 9.34 3.25 8.4 _ - T 32 3450 44.5 113 130 96 237 83 3.8 ,� � w V .._ 1'h(a)to 500 2.00 441 5.13 513 3.79 9.34 3.25 8.4 5.4 y 40 920N 3450 50.8 112 130 130 96 237 83 3.8 24 GROOVED OUTLET 2(a)t 920N 500 2.50 4.38 5.13 5.13 3.79 9.34 3.88 8.5 6.0 50 3450 63.5 111 130 130 96 237 99 3.9 2.7 76.1 mm 920 500 2.75 401 5.13 5.21 3.63 10.51 4.63 8.6 7.6 1 Y rk Z 3450 69.9 110 130 132 92 267 118 3.9 3.4 3(a)t 0 920 500 3 50 4.31 5.50 5.13 3.63 10.51 5.31 10.2 8.4 80 3450 889 110 140 130 92 267 135 4.6 3.8 V Ai rti r r L 4(a)Ta 500 1.50 3.81 5.75 5.38 3.63 10.51 61.5295 10.5 8.4 TI� 100 920 3450 114.3 97 146 137 92 267 4.8 3.8 -gip a - 8 x 2(a)t 920 500 2.75 544 6.19 6.25 4.81 12.42 4.50 11.6 11.6 � �� I 200 50 3450 69.9 138 157 159 122 316 114 5.3 5.3 J 1 2 h(a)t 920 500 2.75 5.07 6.19 6.19 4.81 '.2.42 4.50 11.6 11.6 65 3450 69.9 129 157 157 122 316 114 5.3 5.3 FEMALE THREADED OUTLET 76.1 --"--- 76.1 mm a 920 500 2.75 5.25 6.25 4.81 12 42 4 56 11.6 3450 699 133 159 122 316 116 5.3 3(a)td 500 3.50 5.31 6.50 6.50 4.81 12.42 531 12.6 11.6 • Provides a direct branch connection at 80 920 3450 88.9 135 165 165 122 316 135 5.7 5.3 any location where a hole can be cut 4(a)to 920 500 4.50 4.81 6.75 6.38 4.81 12.42 6.25 15.3 12.5 • in the pipe 100 3450 114.3 122 171 162 122 316 159 6.9 5.7 `*Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). • A pressure responsive gasket provides t Available with grooved or female threaded outlet.Specify choice on order. the seal # Center of run to end of fitting. • Request Publication 11.03 for # Female threaded outlets are available to NPT and BSPT specifications. Mechanical-T cross assemblies @ See page 7 for Fire Protection approvals and pressure ratings.' • Pressure rated up to 500 psi/3450 kPa (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. on steel pipe; also available for use (b)For 76.1 mm threaded outlet,specify 21/2"BSPT clearly on order. with HDPE pipe §Vds approved for fire protection services a LPCB approved for fire protection services • Sizes from 2 x t "/50 x 15mm 0 Approved for use in China by Tianjin Approvals Company. through 8 x 4"/200 x 100mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. • www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. iCtauliC RFV M CARBON STEEL PIPE- HOLE CUT PRODUCTS I 1.V L Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N 11, FLOW DATA Flow test data has shown that the total head loss between point(1)and(2)for the Style 920,920N and 929 Mechanical-To fittings can best be expressed in terms of the pressure difference across the inlet and branch.The pressure difference can be obtained from the relationship below. Q Cv and Kv Values Values for flow of water at+60°F/+16°C are shown in the table below. Formulas for Cv/K,Values: /�J►�� 4P = Q' C Where: Q=Flow(GPM) 1F = Ky Where: 1`1 U AP=Pressure Drop(psi) AP=Pressure Drop(bat) algi Q = C x DP C =Flow Coefficient Q = K, x DP K,=Flow Coefficient Exaggerated for clarity Eqvalent Length of Oiliet Size Schedule 40arbon Steel Pipe (pUL 213,Sec.16) OUTLET SIZE C=120)t FT C,/K,Values yPoNiE1Yu * N etC+R.NM}'�' NOMINAL ACTUAL DIAMETER I O.D. In/nun 1 Inimm GROOVED THREADED ROOVED THREADED yz 0.840 11 15 21.3 2 94 zk 1.050 _ q _ 16 20 26.7 j 13.7 1 1.315 8 21 25 33.7 1.8 1 2 48 32 42.7.7 5 h 6 42.9 41.1Ilk 1'h 1.900 53 53 40 98.3 11 11 45.4 45.4 2 2.375 112 104 50 60.3 9 10 yz 96 89.1 2' 2.875 119 150 65 73.0 20 12 h 102 128.5 76.1 mm 3.000 16* - 161 76.1 138.1 _ 3 3.500 r 249 237 80 88.9 14 15!z 213.4 203.1 4 4.500 421 401 100 114.3 20 22 360.8 343.6 t Hazen-Williams coefficient of friction is 120. *Pipe with a wall thickness of 0.165in./4.2mm. • • www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.C 2012 VICTAULIC COMPANY ALL RIGHTS RESERVED. iCtauI11. 11.02 6 RFV Ai! CARBON STEEL PIPE- HOLE CUT PRODUCTS J. 'L a V L Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N • FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies.Contact Victaulic for performance on other pipe and the latest listings and approvals. Approval Agency Run Size Outlet Size Pipe Rated Working Pressures-psi/kPa ` Actual' _ lids Nominal Outside • - -- Size Diameter I Inches/ram Inches/mm Inches/mm S ule UL ULC FM LPCB (Style 920) (Style 920N) 21/2-6 2.875-6.625 All 10.40 400 400 400 290 232 362 65-150 _ 73.0-168.3 2755 2755 2755 1999 1599 2496 21/2-4 2.875-4.500 All DF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 21/2-4 2.875-4.500 All SF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 6 6.625 3,4 10 300 300 250 290 232 362 150 168.3 2065 2065 1724 1999 1599 2496 6 6.625 3,4 30,40 300 300 300 290 232 362 150 168.3 2065 2065 2065 1999 1599 2496 8 -- 8.625 21/2 10,40 400 _ _ 145 — 200 219,1 2755 1000 8 8.625 34 10 300 _ 250 — 145 _ 200 219.1 2065 1724 1000 8 8.625 3,4 30,40 300 — 300 — 145 — 200 219.1 2065 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. • 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, 4-8"/100-200 MM CARBON STEEL PIPE which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve.The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500psi/3450kPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 47100mm, 57125mm,67150mm and 8"/200 mm diameter pipe.The Style 931 comes with a 21/2"/65mm r grooved outlet The drill motor is an electric motor with ground fault circuit interrupter(GFCI) in accordance with " safety codes. .f a. -,- For more information,refer to publication 24.01. III t_ t a • www.victaulic.com \ICta u ll i VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. RFV M CARBON STEEL. PIPE - HOLE CUT PRODUCTS , V Mechar ical-T° Bolted Branch Outlets STYLES 920 AND 920N • INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. 111 For complete contact information,visit www.victaulic.com 11.02 1480 REV M UPDATED 03/2012 ictaulic VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 11.02 L. 115 Standard Duty Loop Hanger Y 9l 1 F RR t 0 F i ill The 115 Standard Duty Loop Hanger is ideal for suspending stationary, non-insulated pipe lines, including CPVC pipes, in fire sprinkler systems.A knurled insert nut helps simplify vertical adjustments and flared edges on the base(1/2"to 4" sizes) help protect pipes from coming into contact with any sharp edges of the hanger. • Flared edges help prevent any sharp surfaces from coming into contact with the pipe(1/2"to 4" sizes) • Retained insert nut helps ensure the loop hanger and insert nut stay together • Recommended for the suspension of stationary non-insulated pipe lines • Manufactured to use the minimum rod size permitted by NFPA®for fire sprinkler piping • Conforms with Federal Specification WW-H-171 (Type 101, Manufacturers Standardization Society(MSS)SP-58(Type 10) f RS oB A , Material:Steel Finish: Pregalvanized C ® US APPROVED Part Number Pipe Size Outer Diameter Rod Size Static Load OD RS A B C F Certifications 1150050EG 1/2" 0.840" 3/8" 2 13/16" 11/8" 1" 300 lb cULus 1150075EG 3/4" 1.050" 3/8" 3" 1 3/16" 15/16" 300 Lb cULus,FM 1150100EG 1" 1.315" 3/8" 31/4" 1 3/8" 15/16" 300 lb cULus,FM 1150125EG 1 1/4" 1.660" 3/8" 3 9/16" 1 1/2" 15/16" 300 Lb cULus,FM 1150150EG 1 1/2" 1.900" 3/8" 313/16" 1 5/8" 15/16" 300 lb cULus,FM 1150200EG 2" 2.375" 3/8" 4 1/4" 1 7/8" 15/16" 300 lb cULus,FM 1150250EG 2 1/2' 2.875" 3/8" 59/16" 213/16" 19/16" 525 lb cULus,FM 1150300E0 3" 3,500" 3/8" 6 9/16" 31/2" 1 15/16" 525 lb cULus,FM 1150350EG 3 1/2" 4.000" 3/8" 71/16" 33/4" 115/16" 5851b cULus,FM 1150400EG 4" 4.500" 3/8" 7 9/16" 4" 1 15/16" 6501b cULus,FM 1150500EG 5" 5.563" 1/2" 913/16" 43/4" 21/4" 1,000 lb cULus,FM 1150600EG 6" 6.625" 1/2" 115/16" 6 5/16" 35/16" 1,000 lb cULus,FM 1150800EG 8" 8.625' 1/2" 12 7/8" 6 7/8" 2 7/8" 1,000 lb cULus,FM • litIDY + PENTAIR • FM is a registered certification mark of FM Approvals LLC,LTD.NFPA is a registered trademark of National Fire Protection Association,Inc.UL,UR.cUL,cUR,cULus and cURus are registered certification marks of UL LLC. WARNING Pentair products shall be installed and used only as indicated in Pentair's product instruction sheets and training materials.Instruction sheets are available at erico.pentair.com and from your Pentair customer service representative.Improper installation,misuse,misapplication or other failure to completely follow Pentair's instructions and warnings may cause product malfunction,property damage,serious bodily injury and death and/or void your warranty. ®2017 Pentair All rights reserved Pentair,CADDY,CAL/WELD,CRITEC,ERICO,ERIFLEX,ERITECH and LENTON are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners.Pentair reserves the right to change specifications without prior notice. I ' CADDY + PENTAIR .. ...-" _, .7..„ __ .., . . ._...,„ , „ . , -,.... AkirmBUildex. . ... SAmmYS .... 2012 PRODUCT CATALOG www.itwbuildex.com 800-BUILDEX Ii\ .;....: , \ \Ilk\ ,\ \,,, \ II ) , i, , ,. / � `.- _ 7\ , , ,,, , , ,4,,,\,,\,!:, \\k,„,N.,,p044k‘I.,..v. ,.. . /lk,,,,, `� K '!i IiN,„ fr' 'f0fAillr -i 1 M1' �° ,. .,� +r x+ t ,/ o4 , ` r `.1!> / w 6 "Ai " r 3,,,w x 1 TABLE OF CONTENTS Sammys')for Wood 4 Sidewinder for Wood 5 Sammys Swivel Head'for Wood 5 Sammys®for Steel 6 ilk Sidewinder®for Steel 7 Sammys Swivel Head"for Steel 7 Sammy X-Press® 8 Sammy X-Press Sidewinder' 8 Sammy X-Press Swivel"" 9 Sammy X-Press It° Installation Tool 9 Sammys®for Concrete 10 Sidewinder®for Concrete 10 Sammys Swivel Head' for Concrete 11 Concrete/Wood Installation Kit 11 Sammys Toggle' 12 Ceiling Screws 12 Dektite®Pipe Flashing 13 Speedy Pole Tool" 13 Spot Rite Level' 13 11110 Approvals and Listings 14 Special Notes 15 Warranty • Disclaimer of Warranty Proper fastener connection design takes in to account where and how fasteners are used.Allowance for special characteristics in materials,differences in materials,differences in types of materials being joined,unique or unusual environmental service or installation conditions and the safety factors required by anticipating normal or short term loading conditions must be considered.Due to possible differences in specifications,applications,and interpretation of results,purchasers and specifiers must make their own evaluation of the products,to determine the suitability of these products for intended use.All warranties of Buildex products,expressed or implied,including the warranties of merchantabilty and fitness for particular purposes are specifically excluded except for the following:Buildex will repair or replace any product which,within twelve months after sale by Buildex or its distributors,is found by Buildex to be defective in material or workmanship-normal wear and tear accepted.This is the sole warranty of Buildex and the sole remedy available to distributor or buyer.Buildex shall not be liable for any injury,loss or damage,direct,indirect,or consequential,arising out of the use of,or the inability to use,any Buildex product. For the most up to date information,visit www.itwbuildex.com MIIIIMMINMIIIMMIIMMI INSTALLATION INSTRUCTIONS FOR WOOD & STEEL STALLATION STEP - r INTO WOOD&STEEL: INSTALLATION STEPS HORIZONTALINTO WOOD&STEEL: 1.Insert the appropriate nut driver into a 3/8"or 1/2"portable drill. 1.Insert the appropriate nut driver into a 3/8"or 1/2'portable drill. 2.Insert the SAMMYS into the#14(black)nut driver(p/n 8113910).Drill 2.Insert the SAMMYS into the#14SW(red)nut driver(p/n 8114910).With drill should be in a vertical position. unit in a horizontal position and at a right angle to the structural member, begin installation. 3.Push the face of the nut driver tight to the member.Begin installation when the nut driver spins freely on the SAMMYS,stop drill and remove. 3.When the nut driver spins freely on the SAMMYS,stop the drill and remove. 4.The SAMMYS is now ready to receive 1/4",3/8',1/2"or metric all thread rod,bolt stock.(The 1/2"requires the#14SW red nut driver) 4.The unit is now ready to receive 1/4",3/8',M10,M8 or metric all thread rod or bolt stock. Note:When installing DSTR,follow the above instructions,then add retainer nut and torque to 20 foot lbs.for maximumpullout in puffin steel. Note:When installing SWDR,follow the above instructions,then add retainer nut and torque to 20 foot lbs.for maximum pullout in puffin steel. MUM = M, _ .� m H -,,-, 1m ,wi,„ 7 ,,„ , :.:. INSTALLATION INSTRUCTIONS FOR CONCRETE INSTALLATION STEPS- ; INTO CONCRETE: INSTALLATION STEPS-,igigaiiiiiii INTO CONCRETE: 1.Using an SDS 250 carbide tip bit or a HEX RECEIVER with a #250 1.Using an SDS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit,pre-drill the concrete member to a depth of 2"with a carbide tip bit,pre-drill the concrete member to a depth of 2"with a hammer/ hammer/rotary hammer drill set on impact mode. rotary hammer drill set on impact mode. 2.After pre-drilling has been completed,install the SLEEVE TOOL over 2.After pre-drilling has been completed,install the SLEEVE TOOL the bit(the bit should remain in the drill),and insert the#14(black) over the bit(the bit should remain in the drill),and insert the#14SW(red) nut driver(p/n 8113910)into the opposite end(see Vertical Installation nut driver(p/n 8114910)into the opposite end. note above). 3.Insert the SWC screw into the nut driver. 3.Insert the CST screw into the nut driver. 4.Place tip of screw into the pre-drilled hole,turn impact/drill unit to 4.Place tip of screw into the pre-drilled hole,turn impact/drill unit to drill drill mode and begin insertion.When the nut driver spins free on the mode and begin insertion.When the nut driver spins freely on the SWC screw,installation is complete.Stop and remove drill. CST screw,installation is complete.Stop and remove drill. 5.The SWC screw is ready to receive 1/4",3/8"or metric all thread rod 5.The concrete screw is ready to receive 1/4',3/8",1/2",or metric all or bolt stock. thread rod or bolt stock.(#14SW red nut driver used with 1/2"screw) Note:Use a 1200 maximum RPM drill for installation. Note:Use a 1200 maximum RPM drill for installation. Note:Do not install concrete screws while the drill unit is in impact mode- Note:Do not install concrete screws while the drill unit is in impact mode— doing so will destroy the pullout factor of the fastener doing so will destroy the pullout factor of the screw. A A j 4 r-74,--, A . -1,1 '3.,11,,, III SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe Installation each time.When the face of the driver comes into contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. 3 To find a distributor near you,call 800-BUILDEX SAMMYS® FOR WOOD SAMMYS' FOR WOOD - Vertical Application Application Product Features Not less man 2'nominalwidth Wood Flowing •No re•drillin re ulred. p g q 4(1-12")r •Quick to install using the Sammy Not Ins man Nut Driver with an 18V cordless a nominal drilUdriver. thickness(2-1/2') (depth or side wood dot I of vertical member) •Saves time from traditional , Double Sheehodk For vertical use• Ceiling •Reduces installation costs. • install in center of lower lace. - • • Minimum 2'embedment inPo base •Manufactured in the U.S.A. rcaleeal tin 1JFPA 13 compliance. Composite I Truss Consult truss manufacturer far Til s recommended installation point. Pre-drilling may be rsquw^n for GST 25-380.Tool acadaWe 09 page f t iiiWatch a video dopTsl ffiian al www.nwbundex.com) Approvals Rod Pad Model Screw Ultimate UL Test FM Test Box Case Size Number Descriptions Fallout(I—) Load(ibs) Load(ibs) Qty Qty VERTICAL MOU ;!. . '• ..„. ......",. ._ .^ 114" 8002957 GST 100 1l4 x 1" 270(3/4"Ply) 25 125 670 (314"Ply) 114" 8003957 GST 200 114 x 2" 1760 (Fir) 25 125 3/8" 8007957 GST 10 1/4 x 1" 670 (3116"GSB) 300 25 125 670 (314'Ply) 3/8" 8008957 GST20 1/4x2" 1760 (Fir) 850 1475 25 125 318" 8068925 GST20-SS 114x2" 1760 (Fir) 850 25 125 #14 Black 3/8" 8009925 GST25.380 3/8x2-1/2" 2113(Fir) 1500 25 125 Nut Driver (� ' 3/8" 8010957 GST 30 114 x 3" 2060 (Fir) 1500 1475 25 125 Part#8113910 - 3/8" 8069925 GST 30-SS 1/4 x 3" 2060 (Fir) 25 125 1/2" 8013925 GST 2 1/4 x 2" 1760 (Fir) 25 125 i —._ 1/2" 8015925 GST 3 1/4 x 3" 2275 (Fir) 25 125 #14 SW Red Nut Driver Part#8114910 _ % is S SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut dryer for installations. For the most up to date information,visit www.itwbuildex.com 4 ........... . cz,AAHme SIDEWINDER® FOR WOOD -Horizontal Application Application Product Features • • Not less than 2"nominal width •No pre-drilling required. (1-1/2")up to 3-112"pipe;not less than 3'(2.1/7)nominal width 4"a 5'pipe ••Quick to install using the Sammy 1 —► Floor mist Nut Driver with an 18V cordless • Minimum 2-1I2"from bottom for dReduces llldriver.i • March lines.Minimum 3'horn bot- tam for main lines.Exception:This •Saves time from traditiona requirement shall not apply to 2"or methods thicker nailing strips resting on top of steel beams. installation costs. •Manufactured in the U.S.A. Composite I Truss l ceunsult truss manufacturer for recommended installation paint. • • 'Pre.dnCmg may 6e requited ton Model- SWG 253a0.To.available on page 11. (( Watch a video demonsfabon at E 'www.itwbuifdem.com li Approvals Rod Part Model $co w r Ultimate UL Test Box Case Size Number Descriptions Pullout(Ibs) Load(Ibs) Qty Qty HORIZONTAL MOUNT — 114" 8019957 SWG 200 1/4 x 2" 1725 (Fir) 25 125 All _ _ 3/8" 8020957 SWG 10 1/4 x 1" 622 (Fir) 300 25 125 r) 318" 6021957 SWG 20 114 x 2" 1725 (Fir) 1050 25 125 Q 318" 8073925 SWG 20-SS 1!4 x 2" 1725 (Fir) 850 25 125 n 3/87 8022925 SWG 25-380 3/8 x 2-1/2" 2249 (Fir) 1500 25 125 #14 SW Red _ 3/8" 8023925 SWG 30 1/4 x 3" 1884 (Fir) 25 125 Nut Driver Part#8114910 'May require pre-drilling,consult joist manufacturer. SAMMYS SWIVEL HEAD'"' FOR WOOD - Swivel Application , Application Product Features .�2.r: MAP •Eliminates distortion of threaded rod. •Accommodates up to 3 6"x 12 pitch roof. • • • •Allows 17°deflection from vertical, wwu-4 ' •Saves time from traditional methods. i .!i'"» •Reduces installation costs. ,, -= eu:o-. xaaner ia r " •Manufactured in the U.S.A. • r Rod Part Screw Ultimate UL Test Load FM Test Min Box Case Approvals Model Size Number Descriptions Pullout(Ibs) (Ibs) Load(Ibs) Thickness Qty Qty #14 Black SWIVEL MOUNT Nut Driver -L, ". 318" 8139957 SH-GST 20 114 x 2' 1257(Fir) 1050 1475 25 125 Part#8113910 ; 1903 Dim.Lumber .0" 3/8" 8269957 SH-GST/CST 20 5116 x 1314" 1406 @ 45°off vertical 1500 25 125 Dim.Lumber 850 @ 45° i _ 903 Dim.Lumber 1/2' 8303957 SH-GSTICST 2.0 5/16 x 1-3/4" 1406 @ 45°off vertical 25 125 Dim.Lumber 'May require pre-drilling:consult Joist manufacturer. #14 SH Orange • Nut Driver Part#8273910 C C. • 5 To find a distributor near you,call 800-BUILDEX 1 SAMMYS° FOR STEEL SAMMYS® FOR STEEL - Vertical Application Application Product Features •Made with Teksa self-drilling fasteners- no pre-drilling required. --il-A_ •Installs into steel range from 0 20 gauge-112"thicknesses. ' l' { t •Saves time from traditional methods. •Reduces installation costs. Ail/ Quick to install using the Sammys Nut WOE WODriver with an 13V cordless drill/driver. H 7: j$ •A standard screwgun with a depth sensitive € nosepiece should be used to install Teks. _. For optimal fastener performance,the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. • N® ��y�1N� 'Manufactured in the U.SA. pFRt.- SEA . mvAnvk.h - Approvals Rod Part Model Screw Ultimate UL Test FM Test Min Max Box Case Size Number Descriptions Pullout(Ibs) Load(Ibs) Load(Ibs) Thick Thick Qty Qty — VERTICAL MOUNT 114" 8024957 DSTR 100' 1f4-20 x 1"TEKS 3 1510 (20 ga) .036"-20 ga 3116" 25 125 1l4° 8025957 DST 100 1/474 z 1"TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 1/4" 8026957 DST 150 114-14 x 1-1/2'TEKS 3 970 (16ga.) .036"-20ga 3/16" 25 125 1l4' 8027957 DST 200 114-14 x 2"TEKS 3 446(20 ga.) .036"•20 ga 3116° 25 125 1/4" 8030957 TEK 500 12-24 x 1.1/2"TEKS 5 3125 (3116") .188"-3116" 112" 25 125 Q" 318' 8038957 DSTR i' 1/4-20 x 1"TEKS 3 1510 (20 ga.) 1500 1475 .036"-20 ga 3/16" 25 125 9- ;" 318" 8037957 DSTR 1-1/2' 12-24 x 1-1/2"TEKS 5 1510 (3/16") 1500 1475 .060"-16 ga. 1/2" 25 125 .Q- 3M" 8039957 DSTR 516" 5/16-18 x 1.1/4"TEKS 3 2200 (20 ga.) 1500 1475 .036"-20 ga 3116" 25 125 3/8" 8040957 DST 10 1/4-14 x 1'TEKS 3 446 (20 ga.)970 (16 ga.) .036"-20 ga 3116" 25 125 446 3/8" 8077925 DST 10-SS 1/4-14 x 1"TEKS 3 (20 ga-) .036"-20 ga 3/16" 25 125 970(16 ga.) 3/8" 8041957 DST 15 1/4-14 x 1-1/2"TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 #14 Black 970 (18 ga.) Nut Driver 446 (20 ga.) Part#8113910 3i6" 8078925 DST 15-SS 1/4-14 x 1-112"TEKS 3 970 (16 ga.) .036"-20 ga 3116" 25 125 3I8" 8042957 DST 20 114-14 x 2'TEKS 3 446 (20 ga.) .036"•20 ga 3116" 25 125 970 (16 ga.) 318' 8044957 DST 30 1/4-14 x 3"TEKS 3 446(20 ga.) .036"-20 ga 3/16" 25 125 970(16 ga.) a ` 3/8' 8045957 DST 516 5/16-18 x 1-114"TEKS 3 1500 (3116") 1500 1475 .125"-118" 3116" 25 125 _ Q.".% 3/8' 6046957 TEK 50 12-24 x 1-112"TEKS 5 3125 (3/16') 1500 1475 .250'-1M" 1/2' 25 125 112" 8031925 DST 2.0 1/4-14 x 2"TEKS 3 446 (20 ga.) .188"-3/16" 1/4" 25 125 970 (16ga.) _ 1/2' 8033925 DSTR 1.0` 114-20 x 1"TEKS 3 1510(20 ga.) .036"-20 ga 3/16" 25 125 1/2" 8034925 DSTR 5.16' 5/16-18 x 1-1/4"TEKS 3 2220 (20 ga.) .036"-20 ga 3/16" 25 125 1/2" 8035925 DST 5,16 5116.18 x 1-1/4"TEKS 3 1500 (3/16) .125'-1/8" 3/16° 25 125 _ 1/2" 8036925 TEK 5.0 12-24 x 1-112"TEKS 5 3125 (3116") .188"-3/16" 1/2" 25 125 #14 SW Red 'Includes retaining nut Nut Driver Part#8114910 • . SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation ti ]J ®III f $$� each time.When the face of the driver comes into contact with the material you are installing into,continue drilling until nut driver spins l/ wauru,ueo u SA \ �•�w2+ free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. For the most up to date information,visit www.itwbuildex.com 6 Imimisiiimillimiumm OA tG�i111�iIt 7,0 SIDEWINDERr FOR STEEL -Horizontal Application Application Product Features •Made with Tekse self-drilling fasteners-no pre-drilling required. •Installs into steel range from 20 gauge-1/2"thicknesses. 11 ��y ®0111046 •A standard screwgun with a depth sensitive nosepiece should be used to f' 1 y7 install Teks.For optimal fastener performance,the screwgun should be a - - minimum of 6 amps and have an RPM range of 0-2500. ,1,i •Saves time from traditional methods. N. Tg •Reduces installation costs. 4 •Quick to install using the Sammys Nut Driver with an 4 18Vcordlessdrill/drives airne video demonstration)o"er •Manufactured in the U.S.A. i' www.itwbUHdex.cam V Approvals Rod Part Model Screw Ultimate UL Test FM Test Min Max Box Case Size Number Descriptions Pullout(Ibs) Load(Ibs) Load(Ibs) Thickness Thickness Qty Qty 114" 8047957 SWD 100 114-14 x 1"TEKS 3 1477 (16 9a) 050"-16 ga 3/16' 25 125 1/4" 8049957 SWDR 100• 1/4-20 x 1'TEKS 3 1900 (20 ga.) .036"-20 ga 3/16" 25 125 3/8" 8050957 SWD 10 1/4-14 x 1"TEKS 3 1477 (16 ga.) .060"-16 ga 3/16" 25 125 318" 8080925 SWD 10-SS 1/4.14 x 1'TEKS 3 1477 (16 ga.) .080"-16 ga 3116" 25 125 - 3/8" 8052957 SWD 20 1/4-14 x 2"TEKS 3 1477 (16 ga.) .060"-16 ga 3/16' 25 125 Q.` ' 3/8' 8055957 SWDR 1* 1/4-20 x 1"TEKS 3 1900 (20 ga.) 1500 1475 .036"-20 ga 3/16" 25 125 #14 SW Red Q.-'" 3/8" 8054957 SWDR 1-1/2' 12-24 x 1-1/2"TEKS 5 2375 (3/16") 1500 1475 .188"-3/16" 1/2" 25 125 Nut Driver •Q•-''S" 3/8" 8056957 SWDR 516' 5/18-18 x 1-1/4'TEKS 3 2480 (20 ga.) 1500 1475 .036"-20 ga 3/16" 25 125 Part#8114910_ 3/8" 8057957 SWT 15 12-24 x 1-1/2"TEKS 5 2375(3/16") .188"-3/16" 1/2" 25 125 *Includes retaining nut SAMMYS SWIVEL HEAD'"' FOR STEEL - Swivel Application Application Product Features a •Eliminates distortion of threaded rod in sloped roof applications. 4N..401 _ i •Accommodates 3-1/2 x 12 pitch. . •Installs into angled z-purlin;allows threaded rod to hang plumb. 1 •Allows 17°deflection from vertical. i 'Manufactured in the U.S.A. -i1 welchavideo „„eshetbnffi 1 .. www.lrwbulldex.com) ek Approvals Rod Part Model Screw Ultimate UL Test FM Test Min Max Box Case Size Number Descriptions Pullout(Ibs) Load(Ibs) Load(Ibs) Thick Thick Qty Qty _ SWIVEL MOUNT ;_.. #14 Black ti< _�� 1/4-20 X 1" Nut Driver - Q' . 3/8" 8137957 SH-DSTR 1' TEKS 3 3220(3/161 1500 1475 .035' 3116" 25 125 Part It 8113910 2368(1/2"steel Vertical) x 1-314" 1306(45°off Vertical) 1500(Vertical) 4' 111 i a 3/8° 8268957 SH-TEK 50 TEKS 5 2281(3/16"HSS) 850(45°off Vertical) 2-1/2" 3/16" 112" 25 125 1585(3/16"HSS 45°off Vertical) 2368(1/2"steel Vertical) 112" 8270957 SH-TEK 5.0 12-24 x 1.3/4" 1306(45°off Vertical) 3/16" 1/2" 25 125 TEKS 5 2281(3116"HSS) le #14 SH Orange 1585(3/16"HSS 45°off Vertical) Nut Driver — r. Part#8273910 'Does not comply with ROHS requirements/Includes retaining nut 7 To find a distributor near you,call 800-BUILDEX I SAMMY X-PRESS° Installs into Metal Deck, Purlln, or Tubular Steel SAMMY X-PRESS® - Vertical Application Application Product Features •The Sammy X-Press expands to provide •Less jobsite material needed. direct vertical attachment in:�Xp� • light gauge steel deck or purlin No retaining nut required. (22 ga.-118"). •Provides design flexibility. •., •Installs in seconds with Sammy X-Press It Tool, saving time&installation costs. •Manufactured in the U.S.A. •Use in applications where access to the back of • the installed fastener is prohibited.ie.metal roof deck,tubular steel,or vapor barrier fabric. , Warcn a t+rrro ewnonwaem ar • www.i8112dexn"n0 Approvals Rod Part Model Descri lion Ultimate UL Test UL Min FM Test FM Min Max Box Case Application Site Number P Pullout(Ibs) Load(Ibs) Thick Load(Ibs) Thick Thick Qty Qty VER.eY - . ., e, lT .gw.FR,: 14 ,Q 114' 8181922 XP 200 Sammy 1146(22 ga) 185(Luminaire) 0'27" .125' 25 125 Metal Deck X-Press 200 250(Luminaire) OS"o" 850(216"Pipe) .027" 940(2"Pipe) .029' ®.-.i+2 318" 8150922 XP 20 X��Sy� 1146(22 9a) 250(Luminaire) .Ogg^ 1475(4"Pipe) .104' .125° 25 125 Metal Deck 283(Conduit&Cable) .029" 1500(4"Pipe) .060' Q.•%� 318' 8153922 XP 35 Sammy 1783(18 ga) 165(Luminaire) .029' 940 (2"Pipe) .029' .125° 25 125 Pullin X•Press 35 250(Luminaire) .056° 1475(4'Pipe) 104" 416(Conduit&Cable) .059° Metal Pre-Pour Structural Concrete@ 3000 psi (Pre-P — Q- 318' 8150922 XP 20 Sammy X Press 20 1146(22ga) 850(255 Pipe) 25 125 Metal Deck Post-Pour Range II LWC.5 35 PCF(Ibs/8') (Post-Pour) Pre•Pour Structural Concrete @ 30D0 psi Posl•Pour Range It LWCS 35 PCF(Ibs/k') a `S�..y �::y ( �rL �. t� t..J V J �j�/ � � .. t� 4 J V SAMMY X-PRESS SIDEWINDEIV - Horizontal Application Application Product Features •The Sammy X-Press Sidewinder expands to •Less jobsite material needed. I provide horizontal attachment in: e.w a •- -16 ga•3/16°steel-puffin,tubular steel. •No retaining nut required. suer- — r t •Installs in seconds with Sammy X-Press Ito Tool, •Provides design Flexibility. saving time&installation costs. ii •Manufactured in the U.S.A. •Use in applications where access to the back of the installed fastener is prohibited;ie.metal roof (SWXP) deck,tubular steel,or vapor barrier fabric. 4#1*was arMao demonetneanar www.Itwbullldex.com) Rod Part Ultimate UL Test UL Min FM Test Max Box Case Application Approvals Size Number Model Description Pullout(Ibs) Load(Ibs) Thick Load(Ibs) Thick Qty Qty HORIZONTAL MOUNT 1250(3%'Pipe) Sidewinder I. 318" 8293957 SWXP 35 X-Press 35 1798(16ga) 80(Luminaire) .059' .125" 25 125 Pull 416(Conduit&Cable) 0 ' rS MP NUFVCIl'REo u sA For the most up to date information,visit www.itwbuildex.com 8 mummommusasommi ,, A llY N\i'_?Z' II. SAMMY X-PRESS SWIVEL*" - Swivel Application Application Prod:::;g4:59;ures ° • y X--Press Swivel allows you •Less jobsite material needed. mb inexbeme roof pitches:���aee,,, nz-pudin •Noretainingnutrequired.r' n metal deck(or 12l12 pitch Al fog Provides design fir: exibility. (SXP) Dart •Installs in seconds with Sammy X-Press IF Tool, G/' saving time&installation costs. •Manufactured in the U.S.A. j� N OR t !ANI" the in installed where access to the back of pr�L •Use inappl y "'►.' fastener is prohibited.ie,metal roof warcn a e. ,—,a�„eu�A; RiOOT PICKS deck,tubular steel,or vapor barrier fabric. www.lrwbuimex.com Approvals Rod Part Model Description Ultimate UL Test UL Min FM Test FM Min Max Box Case Application ......„ Size Number Pullout(Ibs) Load(Ibs) Thick Load(Ibs) Thick Thick Qty Qty 750(2 Pipe) Swivel 1061(22 ga Vert) 170 Vertical(Luminaire) �'``) '° 3/8" 8294922 SXP 20 X Press 20 829(45°Off Vert) 80 @ 45"(Laminate) .029" 635(2"Pipe) .029' .125" 25 125 Metal Deck IN 283 Vertical(Conduit&Cable) 4 233 @ 45°(Conduit&Cable) 4 1250(3-1/2"Pipe) IN 250 Vertical(Luminaire) .®-. ib" 3/8" 8295922 SXP 35 +Ivel 1675(16 ga Ven) 80 90° Luminaire �' X-Press 35 1558(89°Off Ved) 500@Vertical(Conduit)&Cable( .059 635 (2"Pipet .029" .125" 25 125 Purim 333 @ 89°(Conduit&Cable) 0 a 41) Swivel 1061(22 ga Vert) 1l2" 8272957 SXP 2.0 X-Press 20 829(45°Off Vert) .02T' .125° 25 125 Metal Deck 1r2" 8271957 SXP 3.5 Swivel 1675(16 ga Vert) �• 125° 25 125 TurinX-Press 3.5 1558(89°OR Vert) a. SAMMY X-PRESS IT' Installation Tool ' Application Product Features The Sammy)(Pressexpands to provide direct vertical attachment in: 1kmetal deck(22-16 gauge) .. -z-purlin(18-16 gauge) g raw ' •Manufactured in the U.S.A. Iy •• Watch tlamaieLatmn of wwd wwbud .•. dex.com Part Number Model Description Qty 8194910 UXPIT' Universal X-Press It Tool 1 " 8152910 XPDB 25/64"Drill Bit 1 "Tool Includes:Sleeve,Bit Receiver,Hex Wrench,and 25/64"Drill Bit. • 46 r. 9 To find a distributor near you.call BOO.BUILDEX 1 SAMMYS® FOR CONCRETE SAMMYS® FOR CONCRETE - Vertical Application Application Product Features 15 r. •Easy two step process(Drill hole& '0_. \--,,,._ �c �, drive Sammys concrete anchor). a 4 0 , y;pre-drilled pilot hole required. ` e wav oa0� '1 Concrete Installation Tool availaMefor )I Q' a one tool installation process. ,o ao ,Q •Manufactured in the U.S.A. iao fit •••k:• J•' da •'��L jJ .5�' ' :r_ia °L, f.,ttf:. Y! • .� Y r • • a. e"•• WePoh a video demansfselm at) �wwwidwbuildexcom) Approvals Rod Part Model Screw Ultimate FM Test Box Case Size Number Descriptions Pullout(ibs)` Load fibs) Qty Qty #14 Black 1/4" 8058957 CST 200 5/16 x 1-34' 2400 25 125 Nut Driver .44, 3/8" 8059957 CST 20 5/16 x 1-3/4" 2400 1475 25 125 Pettit 8113910 -"- 3/8' 8145925 CST 20-SS 5/16x1-3/4" 2400 25 125 #14SW Red Nut Driver 112" 8060925 CST 2 6116 x 13/4" 2400 25 125 Part#8114910 'Tested in 3000 PSI concrete SIDEWINDER' FOR CONCRETE - Horizontal Application Application Product Features i ° •Easy two step process(Drill hole&drive Sammys e o 4. r p concrete anchor). io_ri p p°Doe ' '' •'A"pre-drilled pilot hole required. f7 < •Concrete Installation Tool available for a one tool K `7d o C installation process. P' P° ° r a p G r np7o4' Manufactured in the U.S.A. . {gy : u° qo - Wat &video demenshefloc ai wwwilwbuildex.com Approvals Rod Part Model Screw Ultimate FM Test Box Case Sae Number Descriptions Pullout Ohs)" Load fibs) Qty Qty HORIZONTAL MOUNT j U4" 6062957 SWC 200 5116 x 1-3/4" 2450 25 125 iL 3!8" 8061957 SWC 20 5116 x 1.314" 2450 1475 25 125 'Tested in 3000 PSI concrete #14SW Red Nut Driver Part#8114910 SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation ID c1 \,�/ oHs each time.When the face of the driver comes into contact with the material you are installing into,continue drilling until nut driver spins ewurmcnmEo es a free.Installation is then complete,Warranty requires the use of the appropriate nut driver for installations. Forthe most up to date information,visit www.itwbuildex.corn 10 izAl71aiv • ' SAMMYS SWIVEL HEAD"' FOR CONCRETE - Swivel Application Application Product Features •Installs vertically and swivels up to 89°in wood& •• .- z concrete structures, P'f P••�?�aA° p°I •Eliminates distortion of threaded rod. 's: Qy o •1/4"pre-drilled pilot hole required. •Concrete installation tool available for a one piece installation process. t •Manufactured in the U.S.A.Et\I%r Approvals Rod Part Model Screw Ultimate Box Case Size Number Descriptions Pullout Obsp Qty Qty 2537 in 3000 psi concrete 318" 8269957 SH-GST/CST 20 5/16 x 1.3/4• 1459 @ 45"off vertical in 3000 psi concrete 25 1° 2852 in 6000 psi concrete 1636 @ 45"off vertical in 6000 psi concrete — `'r '-' ^�' - 2537 in 3000 psi concrete 5 1459 @ 45°off vertical in 3000 psi concrete 1/2" 8303957 SH-GSTICST 2.0 5116 x 1.3i4" 2852 in 6000 psi concrete 25 125 #14 SH Orange 411 Nut Driver 1636 @ 45°off vertical in 6000 psi concrete Part 4 8273910_ Note:UL Listed for wood-see pages `Tested in 3000 PSI concrete ^••••• 4 N CONCRETE I WOOD INSTALLATION KIT 4 t Application 2 C Rotary Hammer Drill into concrete Hammer Drill into concrete (; (b)(b) (g) (d) .�(hi ' `� or "VI (h) +�immial� � �� MMIIII JF Part Number Description Each Qty • 8122910 Concrete Installation Kit(a) Kit includes the following items: 8113910 #14 Black Nut Driver(b) 1 8114910 #14 SW Red Nut Driver(c) 1 8116910 #250 Bit(1/4")(d) 1 8117910 SDS Bit(1/4")(e) 1 8118910 7/32 Wood Bit(f) 1 8120910 HEX 250 Bit Receiver(1/4")(g) 1 8098910 SL 250 Sleeve(h) 1 • 8121910 SDS B250 Bit Receiver(1/4")* 1 `Only sold separately-not included in kit. lei 11 To find a distributor near you,call 800-BUILDEX 1 ACCESSORIES SAMMYS TOGGLE" Application Installation Steps tle 1.Pre-drill a 5/6'hole with a regular drill orhole saw. Ili f t ^ 2.Insert SST screw into#14 black nut drives With wing nut and n_:_, i C washer on bolt,insect wing nut through surface,and begin installation. 3.When bolt is secure and nut driver spins free,stop drill motor and remove. Pre-Cast Hollow Core 4.SST screw is now ready to receive 1/4",3/8",or Metric all Concrete thread rod or boll stock. ii• i-- I Rod Size Part Number Model Screw Descriptions Ultimate Pullout(Ibs) Box Qty Case Qty 1l4" 8063925 SST 300 1/4 x 3" 450 (Lath 8 Plaster) 25 125 404 (2 Layers 5/8 Rods) 3/8' 8064925 SST 30 i l4 x 3" 450 (Lath&Plaster) 25 125 #14 Black — 404 (2 Layers 5/8 Rock) Nut Driver Part#8113910 Application Product Features •3/16"eyelet to accommodate common wire size. - •ICC approvals can be found at "' ''"- www.ltwbuildex.com under Evaluation Report#ER-5367. oil i 7 Use the ,Il Soeedy Pole Tool" A for easy installation of ceiling screws without ladders or scaffolding! (see pg 13 for details) Approvals Substrate Part Model Point Description Overal Total Ultimate ax ICC Test Box Case Number Length Pullout(Ibs) G.uge Load(Ibs) Qty Qty ICC STEEL 8107957 CWSD 1' Teks 1/4 x 1" 2' 472 (20 ga) 16 ga. 170 (20 ga.) 25 125 ICC STEEL 8190957 CWSD 15' Gimlet 1!4 x 1-112' 2-3/4" 472 (20 9a) 20 ga. 170 (20 ga.) 25 125 WOOD Teks 1393(Fir) ICC STEEL 8108957 CWSD 2* Teks 1/4 x 2' 3-114" 472(20 ga) 16 ga. 170(20 ga.) 25 125 CWIT ICC 8110910 CWIT Installation Tool 1 Installation Tool 'Does not comply with ROHS requirements Part#8110910 For the most up to date information,visit www.itwbuildex.com 12 miimiiii gAMIATVO'" 11.- DEKTITE® PIPE FLASHING Application Product Features •Complies with NFPA 13 Code Changes. s STAY !UP TO •Flashing for dry pendant sprinklers subject to F-DEKTITE extreme temperature changes. CODE! •One piece construction is easy to install. '{ CLEAI1AIICE •Pipe diameter markings ensure accurate fit. more efficient way _< XOLE to flash your •EPDM temperature range of-65°F to+250°F. refrigeration/freexer unite;. INSULATED FREEZER 1 STRUCTURE 4 E-DRY SPRINKLER Part Number Description Pipe Outside Diameter Dektite Base Diameter Dektite Height Box Qty 4001910 Mini 1/4"-1-1/8" 3-1/2" 1-3/4" 20 4003910 1 1/4"•2" 4.3/4" 3" 10 4004910 2 1-3/4"-3-1/4" 6-1/4• 4" 10 SPEEDY POLE TOOL' & UNIVERSAL SOCKET KIT Universal Pole Tool Socket Kit(8129910)Includes: Product Features ._'"•"'- - - •Adaptor Plug(a) •The Pole Tool and Universal Socket Kit '° •Socket Driver for SAMMYS(b) provide easy and safe installation for. •Socket Driver far Ceiling Wire Screws(c) (a) 'Socket Driver for 1/4"Standard Nut Drivers(d) -Sammys -Jack Chain 1 •Stud Plug for Viper or Ladd Powder Actuated Attachment(e) -Threaded Rod -Wire I''i -Pencil Rod -Screws f• ',talk (Items not sold seperate/y) -Ceiling Screws ', k (e) -: (b)(a WetMewtleo Eem°nsbatlonei •Ideal for retrofit and hard"to-reach projects in Ali www.i[Wbuildex.com, wood and steel. Part Number Description Box Qty 8123910 Pole Tool 6'(3'-6') 1 �•�. 8124910 Pole Tool 12'(4'-12') 1 V 8125910 Pole Tool 18'(6'-18') 1 4 8126910 Pole Tool 24'(8'•24') 1 wei s, 8127910 Sammys Socket Driver 1 C 8128910 Ceiling Wire Socket Driver for wire and chain 1 V s 8129910 Universal Pole Tool Socket Kit • V 4 SPOT-RITE LEVEL' C Part Number Model Ea.Qty Product Features Q `r ate. 8130910 Spot Rite Level 1 •1l2",3/4°,and 1"threading -. �r we •Magnetic strip for ease of use - /,� �- •Pocket Sized • �. ,, t . IPA \ •Lightweight •3-vial design for measurement of 0°,45°,and 90°angles 0.4 • E; • 13 To find a distributor near you,call 800-BUILDEX APPROVALS Part Model Rod Size Mount UL Max UL Test UL Min Wood FM Max FM Test FM Min Wor Number Direction Pipe Size Load fibs) Pipe Size Load fibs) SAMMYS FOR WOOD-PIPE HANGER07957 GST to 8020957 SWG 10 80 3/8" Vertical CPVC 1.112" 300 1-1/2° 3/8" Horizontal CPVC 1-i12" 300 1-1/2" 8008957 GST20 8068925 GST20•SS 8010957 OST 30 3/8" Vertical 2-1l2" 850 1-1/2" 4" 1475 1-112" 318" Vertical 2-112" 850 1-112" 3/8" Vertical4" 1500 1.1/' 4" 1475 14/2" 8009925 GST25380 3/8" Vertical 4" 1500 i-1/2" 8022925 SWG 25-380 3/8° Horizontal 3-if2"-4'" 1500 1-112" 8021957 SWG 20 3/8" Horizontal 2-1/2"•3°" 1050 1-1/2" 8073925 SWG20-SS 3/8" Horizontal 2-112" 850 1.1/2" 8269957 SH-GSTICST 20 3/8" 45°Angle off Vertical 2.112" 850 1.1/2" 8269957 SH-GST/CST 20 3/8" 45°Angle off Vertical 4" 1500 1.1/2' 8139957 SH-GST 20 3/8" 17°Angle off Vertical 3" 1050 1-1/2" 4" 1a75 1-1/2" SAMMYS FOR STEEL•PIPE HANGER -,.. Min Steel Thick 1.11.1111 Max Steel Thick 8038'357 DSTR 1 318' Vertical 4" 1500 .035° 4' 1475 .105' 8037957 DSTR 1-112 318" Vertical 4° 1500 .035" 4" 1475 .105° 8039957 DSTR 516 3/8" Vertical 4" 1500 .037" 4' 1475 .105" 8045957 DST 516 3/8" Vertical 4" 1500 .188" 4" 1475 .188" 8046957 TEK 50 3/8" Vertical 4" 1500 .250" 4" 1475 .188° 8055957 SWDR 1 318" Horizontal 4" 1500 .037" 4" 1475 .060" 8056957 SWDR 516 3/8° Horizontal 4' 1500 .037° 4" 1475 .060" 8054957 SWDR 1-1/2 3/8" Horizontal 4' 1500 .037" 4° 1475 .060" 8137957 SH-DSTR 1 3I8" 17°Angle off Vertical 4" 1500 .035" 4" 1475 .105" 8268957 SH-TEK50 3/8" Vertical 2-112" 850 70°Angle o8 Vertcal 4" 1500 8150922 XP 20 3/8° Vertical 2.112" 850 .02 2" 940 .029° 7" 4" 1475 .105" 8153922 XP 35 3/8" Vertical 4" 1500 .060" 2" 940 .029" 4" 1475 .125" 8294922 SXP 20 3/8" Vertical or up to 45° 2" 750 .027" 2" 635 .029' 8295922 SXP 35 3/8" Vertical or up to 89° 3-1/2" 1250 .060" 0 635 .029". 8293957 SWXP35 3/8" Horizontal 3-1/2" 1250 .080" SAMMYS FOR CONCRETE-PIPE HANGER 8059957 CST 20 318" Vertical 4" 1475 3000 8061957 SWC 20 3/8" Horizontal 4" 1475 3000 8150922 XP 20 3/8" Vertical 2-1/2" 850 Pre-Pour Structural @ 3000psi 8150922 XP 20 3/8° Vertical 2-1/2' 850 Post-Pour Range II LWC s 35 PCF(Ibs/fi) Part Model Rod Mount UL Load UL Min Steel Number Size Direction Rating(Ihs) Thickness SAMMYS FOR STEEL-LUMINAIRE FITTING 185 027" 8150922 XP20 3/8° Vertical 250 .035" 185 .027" 8153922 XP 35 3/8' Vertical P50 .035° 185 .027" 8181922 XP200 1/4" Vertical 250 .035" Vertical 170 .027" 8294922 SXP 20 318" 45° g0 .027" Vertical 250 .060" 8295922 SXP 35 318" 90° 80 Ogg 8293957 SWXP35 3/8" Horizontal 80 .060" Part Rod Mount UL Load UL ick.Steel Listed Model Number Size Direction Ryating(Ibs) ThickneThickness 'SAMMYS FOR STEEL-CONDUIT, ' -" --r+ 8150922 XP 20 3/8" Vertical 283 .027" Max 4 trade size EMT,RMC,and IMC 8 5 trade size rigid PVC conduit 8153922 XP 35 3/8" Vertical 500 .060" Max 4 trade size EMT&6 trade sze RMC.IMC,and rigid PVC conduit 8294922 SXP 20 3/8" Vertical 283 .027° Max 4 trade size EMT,RMC,and IMC&5 trade size rigid PVC conduit 8295922 SXP 35 3/8" Vertical 500 .060" Max 4 trade size EMT&6 trade sze RMC,IMC,and rigid PVC conduit 8293957 SWXP 35 318° Horizontal 500 .060" Max 4 trade size EMT&6 trade sze RMC,IMC,and rigid PVC conduit 8149957 CZ2000 114'or 3/8' Onto Vertical Rod UL Listed 4516-Cable Hanger,Cat.No.C-72000 Plenum Rated, Complies W!NEC Standards Gauge No. 22 ga. 20 ga. 18 ga. 16 ga. 14 ga. 12 ga. 118" 3/16" 114 Nominal Decimal Equivalent .030" .036" .048" .060° .075" .105° .125" .188" .250" 'SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-112" UL compliance with NEC Standards. -SWG 25-380 Maximum pipe size in wood timber or joist allowed by UL is 4° UL and FM tests were performed in compliance with NFPA 13 Standards. "SWG 20 Maxmum pipe size in composite wood joist allowed by UL is 2-112" Fastening requirement:5 times weight of water-filled schedule 40 pipe plus 250 pounds. -SWG 20Madmum, e size in wood timber or•,'st allowed UL is 3* For the most up to date information,visit www.itwbuildex.com 14 SPECIAL NOTES • • Engineering Note • In 1996,the anchors listed by UL were tested in plate steel that measured.188"and.118".Subsequent testing was done for z-puriin applications in May 1997 using(.037")or 20 gauge steel.Most recently in 2008,testing with the new Sammy X-Press was completed using(.030")or 22 gauge steel metal deck. Sammys®Nut Drivers Special nut drivers were designed to be used with Sammys.When the appropriate nut drivers are used for installation,the driver spins freely on the screw after installation is complete and eliminates the expected wrist snap,reduces over-torque,and prevents screw failure. Steel Screws Due to variations in hardness of certain metals,it should be noted that our self-drilling screws for steel will experience different drill speeds.500-1500 RPM drill speed should be used. Metric Products Metric versions of the Sammy anchors are available at www.itwbuildex.com Sammys for Seismic Please visit www.itwbuildex.com for our current Seismic product offerring. Vibratory Environments For attaching or anchoring in high vibratory environments,special care should be taken not just for building attachments but also for the hangers or assemblies being supported. Consult local code authorities for accepted anchoring devices. Composite Joist/Truss Truss manufacturers vary installation recommendations for composite joist.UL testing was completed to validate that Sammys and Sidewinders SWG 20 and SWG 25-380 can be installed into the top cord of a truss.Sammy GST 20 can be installed into the center of the lower cord of a composite joist.Penetration of the upright center web is permitted by t some joist manufacturers.Consult truss manufacturer for recommended installation point. Pre-drilling may be required by joist manufacturers.If so,pre-drill pilot hole 118"smaller than root diameter of fastener. Consult the table below: Model Root Diameter Hale Size GST 20 .182" 1/8" GST25-380 .280" 7/32" SWG 20 .182" 1/8' 410 SWG 25-380 .280" 7/32" To increase efficiency of the installation process,sleeve tools,bit receivers,and wood bits are available for pre-drilling. NFPA/NEC Standards All UL and FM testing complies with NFPA 13 and NEC standards.Check with your local(AHJ)Authority Having Jurisdiction to confirm application and usage. UL Listings/FM Approvals UL and FM reports are available at www.itwbuildex.com UL us M4FEP ALSO LU1MO AS COW.AND CABLE MERO:PR M" " • PPE POO LIMAS Mk MGM MUM LUPMER NCI Technical Drawings Technical drawings are available and can be downloaded at www.itwbuildex.com in the following formats:.dwg,.dxf,and.igs. Manufactured in the U.S.A.Products NM A Contact Information NLONUFAGIVIED °s Technical Assistance:(800)BUILDEX Option#6(x 3259) P' Customer Service:(800)BUILDEX Option#1 V • C a a a Q 15 To find a distributor near you,call 800-BUILDEX ' *r• . f CATALOG ISSUE 4. , ( S-_ 2012 . . . � ‘ / BUILDING IDEAS THAT WORK FOR OVER 40 YEARS! QUALITY0 .. ,, ,..,. . „... , , i., ,..,,. ,�, At ITW Buildex we pride ourselves on serving the construction industry for Nr.,s L,. over 40 years with innovative,quality products that help our customers save `,,.., •,.,.' Lf' time and money. We are commited to our customers by providing world �"•1 •� U 4 class customer service and technical support.We are here to help! ... /, 1/4..,_ \.,. L 1/4..i ' ./_. 1/4,- 1,. 4..., \..r •L./ ` • `., \4 ` , .. 1/ 4/'. V -- `,I 1/4..., `...i 1 L Li \..' \. Li \, S. ‘ii . `i u — `/ hiloioaa aii wBuildex 4 49 W. Bryn Mawr Ave. Itasca, IL 60143 (P)800-BUILDEX ;' (F)630-595-3549 ?`i'www.itwbuildex.com F -£ Sammys°,Sammy X•Press`.Sammy*Press -,Sidewinder.Sammy X-Preas Swivel". :` >a^ Sammy*Press Sidewinder`.Tapwn°,Sammy Sadd `,Speedy Pale Trot.Spot-Rite Level', Oektile'.Swivel Head'".Sammys Toggle`.and leks'am trademarks of lbwis Tool Works Inca ncklle°,a reg sl:r d trademark of Deks hdusines Ply Lid, 5201'11W Bupt a ad IL,als Taalw,rks H-. Worldwide • www.tyco-fire.com t coo Contacts y Series TY-6 - 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage IMPORTANT The TY-B Recessed Pendent Sprinkler, where applicable,is intended for use in -. ",,:.- ^> " Refer to Technical Data Sheet areas with a finished ceiling. It uses a ,�'° TFP2300 for warnings pertaining to two-piece Style 10(1/2 in. NPT)or Style G "` `i regulatory and health information. 40(3/4 in. NPT)Recessed Escutcheon. ' Always refer to Technical Data The Recessed Escutcheon provides i • Sheet TFP700 for the "INSTALLER 1/2 in. (12,7 mm) of recessed adjust- { WARNING" that provides cautions ment or up to 3/4 in. (19,1 mm)of total with respect to handling and instal- adjustment from the flush pendent 1 lation of sprinkler systems and com- position. The adjustment provided by ponents. Improper handling and the Recessed Escutcheon reduces the installation can permanently damage accuracy to which the fixed pipe drops a sprinkler system or its compo- to the sprinklers must be cut. nents and cause the sprinkler to fail Corrosion-resistant coatings, where 1 to operate in a fire situation or cause applicable, are utilized to extend it to operate prematurely the life of copper alloy sprinklers beyond what would be obtained Scan the OR code or enter the URL when exposed to corrosive atmo- in a web browser to access the most spheres. Although corrosion-resistant coated sprinklers have passed the up-to-date electronic version of this (' document. Data rates may apply. standard corrosion tests of the g cable approval agencies, the testinsting _ =..,- 1 , o is not representative of all possible corrosive atmospheres. Consequently, it is recommended that the end-user be The owner is responsible for maintain- • 1 consulted about the suitability of these ing their fire protection system and y •� Ii•• • t coatings for any given corrosive envi- devices in proper operating condi- • r r ronment. The effects of ambient tern- tion. Contract the installing contrac- Y CVperature, concentration of chemicals, tor or product manufacturer with any and gas/chemical velocity, should be questions. i•. J• considered as a minimum, along with • 1 NFPA prohibits installation of in. the corrosive nature of the chemical to NPT sprinklers with K-factors greater 1 - ' 0 which the sprinklers will be exposed. than 5.6 in new construction. They are An intermediate level version of the intended for retrofit in existing sprinkler Series TY-B Pendent Sprinkler can be systems only docs.jci.com/tycofire/ obtained by utilizing the Series TY-B series-ty-b-2-8_5-6-and-8k Pendent Sprinkler in combination with Sprinkler the Model S2 Shield. General NOTICE Identification The Series TY-B 2.8,5.6,and 8.0 K-fac Description tor, Upright, Pendent, and Recessed Numbers (SIN) Pendent Sprinklers described herein TY1151 . . . Upright 2.8K, 1/2 in. NPT The TYCO Series TY-B 2.8, 5.6, must be installed and maintained in TY1251 . . .Pendent 2.8K, 1/2 in. NPT and 8.0 K-factor, Upright, Pendent, compliance with this document,as well TY3151 . . . Upright 5.6K, 1/2 in. NPT and Recessed Pendent Sprin- as with the applicable standards of the TY3251 . . .Pendent 5.6K, 1/2 in. NPT klers described herein are standard National Fire Protection Association response, standard coverage,decora- TY4151 . . . Upright 8.0K, 3/4 in. NPT tive 5 mm glass bulb-type spray sprin- (NFPA), in addition to the standards of TY4251 . . .Pendent 8.0K,3/4 in. NPT anklers.They are designed for use in light, Failure to do so may im other authorities pair the the perfor- ordinary, urisdiction. TY4851 . . . Upright 8.0K, 1/2 in. NPT or extra-hazard commercial TY4951 . . .Pendent 8.0K, 1/2 in. NPT occupancies such as banks, hotels,• shopping malls, factories, refineries, mance of these devices. and chemical plants. Page 1 of 10 NOVEMBER 2021 TFP151 TFP151 ' Page 2 of 10 CEILING PLATE 1 - Frame 5 - Compression • SEATING SURFACE 2 - Button Screw 7 3 Sealing 6 Deflector* T1i Assembly 7 - Bushing 61111 ___,..._________ _____ 1 4 - Bulb git 7/16" �; \� (11,1 mm) 2-1/4" 3 NOMINAL A # (57,2 mm) �r 'IC MAKE-IN I 2 *Temperature rating is r�l 2-3/16" 111 ' 1-9116" 4 indicated on Deflector. (55,6 mm) I (39,7 mm) . 5 ** Pipe thread connections \ •W� per ISO 7-1 can be /%fl!ti�\ .v< . 6* provided on special 1/2"NPT** T WRENCH request. FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 1 SERIES TY-B UPRIGHT(TY1151)AND PENDENT(TY1251)SPRINKLERS 2.8 K-FACTOR, 1/2 IN. NPT, STANDARD RESPONSE *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 6L 1. AV, _ 1 W 7/16' iu�-- iffl 3 t10MINAL A �% • !� 2 MAKE-IN (556/m) I1;IMAI 2-3/16" tit 4� j (55,6 mm) '� 38 1/mm 6. � � ilk 1/2"NPT** I WRENCH STYLE 10 I- 2-7/8"(73,0 mm)DIA. FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION ALL FINISHES EXCEPT POLY-STAINLESS WRENCH 1/2" ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated SURFACE 4 - Bulb 6 - Deflector* on Deflector. Ai,'//77PTIIP'INNt F\ i 1 gill (11,11mm) o�1 1 3 NOMINAL 1 2-3/16" O: 10 �` �"2 (.. MAKE-IN I (55,6 mm) lir 1 4 __� 2-3/16" 1-1/2" ' (55,6 mm) (38,1 mm) , ,I 8 STYLE 10 2-7/8" (73,0 mm)DIA. --- — RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION POLY-STAINLESS FINISH ONLY FIGURE 2 SERIES TY-B UPRIGHT(TY3151)AND PENDENT(TY3251)SPRINKLERS 5.6 K FACTOR, 1/2 IN.NPT, STANDARD RESPONSE 0 • TFP151 Page 3 of 10 S *Temperature rating ** Pipe thread connections per 1 Frame 3 Sealing 5 Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 1 1/2" �= 3 (12,7 mm) Ill NOMINAL I—I } 2-5/16" 1116111z - 2 MAKE-IN I (58,7 mm) �— 4 2-1/4" I 1-9/16" (57,2 mm) (39,7 mm) . --- 5 6 3/4" NPT** t WRENCH STYLE 40 1- 2-7/8"(73,0 mm)DIA. FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION ALL FINISHES EXCEPT POLY-STAINLESS WRENCH 3/4" ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated SURFACE 4 - Bulb 6 - Deflector* on Deflector. _ fa AP' 1 r 1/2" � 52 (12,7 m"m)NOMINAL ` 2 I MAKE-IN (58,7 mm) ç ` �\`1 4 = 2-1/4" 1-9/16" (57,2 mm) (39,7 mm) 5 STYLE 40 2-7/8"(73,0 mm)DIA. RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION POLY-STAINLESS FINISH ONLY FIGURE 3 SERIES TY-B UPRIGHT(TY4151)AND PENDENT(TY4251) SPRINKLERS 8.0 K-FACTOR, 3/4 IN. NPT, STANDARD RESPONSE CEILING PLA/-f-TE 1 - Frame 5 - Compression ________._ ___ ___ SEATING SURFACE 2 - Button Screw 1 3 Sealing 6 Deflector* i ze Assembly i-r�- t'� y 3 6 4 Bulb A6" 11,17/1mm 2-1/4" i*( ) 4 (57,2 mm) �1 2 NOMINAL MAKE-IN *Temperature rating is r�r 2-3/16" I� 1-9/16" 4 indicated on Deflector. (55,6 mm) (39,7 mm) .--' 7 5 ** Pipe thread connections \ -_- ,fi�r per ISO 7-1 can be 6* provided on special 1/2"NPT** WRENCH request. UPRIGHT FLATS PENDENT CROSS SECTION FIGURE 4 SERIES TY-B UPRIGHT(TY4851)AND PENDENT(TY4951)SPRINKLERS 8.0 K-FACTOR, 1/2 IN.NPT, STANDARD RESPONSE • TFP151 • Page 4 of 10 2-7/8" DIA. 2-7/8"DIA.- - 5/8t1/4" (73,0 mm) 3/4"(19,1 mm) 5/8t1/4" (73.0 mm) 3/4'(19,1 mm) 11110 (15,9±6,4 mm) 1/4'(6,4 mm) (15,9±6,4 mm) 2-1/4"DIA. 1/4"(6,4 mm) �_ 2-1/4"DIA. y (57,2 mm) FACE OF (57,2 mm) MOUNTING FACE OF MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" / (3,2 mm) /i r 1 , a_i_ (3,2 mm) I —,l �q L, \ MOUNTINGlit 1 " f MOUNTING t SURFACE �Imt SURFACE CLOSURE SERIES 1-1/4"(31,8 mm) CLOSURE SERIES 1-5/16"(33,3 mm) TY B 3/4"(19,1 mm) TY B 13/16"(20,6 mm) FIGURE 5 FIGURE 6 SERIES TY-B RECESSED PENDENT SPRINKLER SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 IN. TOTAL ASSEMBLY WITH TWO-PIECE 3/4 IN. TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 IN.NPT 8.0 K-FACTOR,3/4 IN.NPT c, Technical Operation Data The glass bulb contains a fluid which WRENCH RECESS expands when exposed to heat.When (END"A"USED FOR Approvals the rated temperature is reached, the „1010/6"°° 1/2"NPT MODELS) UL and C-UL Listed fluid expands sufficiently to shatter the FM,LPCB,VdS,and NYC Approved glass bulb, allowing the sprinkler to • See Tables A,B and C for complete approval activate and water to flow. WRENCH RECESS information, including corrosion-resistant (END"B"USED FOR status. Design 3/4"NPT MODELS) Maximum Working Pressure Criteria See Table D FIGURE 7 Discharge Coefficient W-TYPE 6 m s (40,3 L The TYCO Series TY-B 2.8, 5.6, and K=2.8 SPRINKLER WRENCH gp /pip Pm/barn=) 8.0 K-factor, Upright, Pendent, and K=5.6 gpm/psis(80,6 Lpm/bar1/2) Recessed Pendent Sprinklers are K=8.0 gpm/psiY(115,2 Lpm/bar'h) intended for fire protection systems WRENCH Temperature Ratings designed in accordance with the stan- RECESS See Tables A,B and C dard installation rules recognized by Finishes the applicable Listing or Approval agency, such as UL Listing based on -tom Sprinkler:See Table E the requirements of NFPA 13 and FM 11 Recessed Escutcheon:Signal or Pure White, Approval based on the requirements Grey Aluminum,Jet Black,Chrome Plated, of the FM Global Loss Prevention Data or Natural Brass Sheets. Use only the Style 10 or 40 Physical Characteristics Recessed Escutcheon, as applicable, �,�, Frame Bronze for recessed pendent installations. Button Brass/Copper PUSH WRENCH Sealing Assembly..Beryllium Nickel w/TEFLON IN TO ENSURE Bulb Glass ENGAGEMENT Compression Screw Bronze WITH SPRINKLER Deflector Copper WRENCHING AREA Bushing(K=2.8) Bronze FIGURE 8 Poly-Stainless W-TYPE 7 RECESSED Physical Characteristics SPRINKLER WRENCH Frame Bronze Button L316 Stainless Steel' Bulb Glass Compression Screw L316 Stainless Steel' Deflector Copper/Bronze Sealing Assembly.Gold Plated Beryllium Nickel w/TEFLONIII 'Type L316 stainless steel(UNS 31603)per ASTM A479/479M or BS EN 1008 WN1.4404. TFP151 Page 5 of 10 Bulb Sprinkler Finish8 • K-Factor Sprinkler Temperature Liquid Wax-Over- Type Rating Color Natural Chrome Pol ester Pol Stainless° Lead Wax Lead Brass Plated y y Coated Coated Coated 135°F(57°C) Orange Upright 155°F(68°C) Red (TY1151) 2.8 and 175°F(79°C) Yellow 1,2,3 1/2 in. N/A N/A: NPT Pendent 200°F(93°C) Green (TY1251) Figure 1 286°F(141°C) Blue 360°F(182°C) Mauve 1,2 NOTES 1. Listed by Underwriters Laboratories,Inc.(UL). 2. Listed by Underwriters Laboratories,Inc.for use in Canada(C-UL). 3. Approved by FM Global(FM Approvals). 4. Approved by the Loss Prevention Certification Board(LPCB Ref.No.007k/03). 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved.(For details,contact Johnson Controls,Enschede,Netherlands,Tel.31-53-428-4444/Fax 31-53-428-3377) 7. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/05) 8. Where Polyester Coated,Lead Coated,Wax Coated,and Wax-over-Lead Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers.Where Lead Coated,Wax Coated,and Wax-over-Lead Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as Corrosion-Resistant Sprinklers. a. Installed with Style 10(1/2 in.NPT)or Style 40(3/4 in.NPT)3/4 in.Total Adjustment Recessed Escutcheon,as applicable b. 150°F(66°C)maximum ceiling temperature c. Frame and deflector only d. Not Applicable(N/A) TABLE A SERIES TY-B 2.8 K-FACTOR UPRIGHT AND PENDENT SPRINKLERS LABORATORY LISTINGS AND APPROVALS Sprinkler Temperature Bulb Sprinkler Finish(' K-Factor Liquid Wax-Over- Type Rating Color Natural Chrome Polyester' Poly-Stainless Lead Wax Lead • Brass PlatedCoated Coated Coated 135°F(57°C) Orange 155°F(68°C) Red Upright 1,2,3,5 1,2,3,5 (TY3151) 175°F(79°C) Yellow 1,2,3,5,6 1,2 1,2,3,5 Figure 2 200°F(93°C) Green 286°F(141°C) Blue 1b,2b,3b,5b lb,2b,3b,5b 360°F(182°C) Mauve N/A 135°F(57°C) Orange 155°F(68°C) Red 1,2,3,5 1,2,3,5 5.6 Pendent 175°F(79°C) Yellow 1/2 in. (TY3251) 1,2,3,5,6 1,2 1,2,3,5 NPT Figure 2 200°F(93°C) Green 286°F(141°C) Blue lb,2b,3b,5b ib,2b,3b,5b 360°F(182°C) Mauve N/A 135°F(57°C) Orange Recessed 155°F(68°C) Red 1,2,3,5 (Pendent 175°F(79°C) Yellow 1,2 N/A Figure 5 200°F(93°C) Green 286°F(141°C) Blue 1,2 NOTES 1. Listed by Underwriters Laboratories,Inc.(UL), 2. Listed by Underwriters Laboratories,Inc.for use in Canada(C-UL). 3. Approved by FM Global(FM Approvals). 4. Approved by the Loss Prevention Certification Board(LPCB Ref.No.007k/03). 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved.(For details,contact Johnson Controls,Enschede,Netherlands,Tel.31-53-428-4444/Fax 31-53-428-3377) 7. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/05) 8. Where Polyester Coated,Lead Coated,Wax Coated,and Wax-over-Lead Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers.Where Lead Coated,Wax Coated,and Wax-over-Lead Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as Corrosion-Resistant Sprinklers. • a. Installed with Style 10(1/2 in.NPT)or Style 40(3/4 in.NPT)3/4 In.Total Adjustment Recessed Escutcheon,as applicable b. 150°F(66°C)maximum ceiling temperature c. Frame and deflector only d. Not Applicable(N/A) TABLE B SERIES TY-B 5.6 K-FACTOR UPRIGHT AND PENDENT SPRINKLERS LABORATORY LISTINGS AND APPROVALS TFP151 • Page 6 of 10 • Sprinkler Temperature Bulb Sprinkler Finish8 K-Factor Liquid Wax-Over- • Type Rating Color Natural Chrome polyesters.Poly-Stainless° Lead W'ax Lead Brass Plated Coated Coated Coated 135°F(57°C) Orange Upright 155°F(68°C) Red (TY4151) 1,2,3,5 1,2,5 and 175°F(79°C) Yellow 1,2,3,4,5,6,7 1, 2 1,2,5 Pendent Pende1t 200°F(93°C) Green 8.0 • Figure 3 286°F(141°C) Blue lb,2b,3b, 5b 1b,2b, 5b 3/4 in. 360°F(182°C) Mauve N/A NPT • 135°F(57°C) Orange Recessed 155°F(68°C) Red Pendent 1, 2,3,4,5 (TY4251 175°F(79°C) Yellow 1,2 N/A Figure 6 200°F(93°C) Green 286°F(141°C) Blue 1,2 • 135°F(57°C) Orange Upright 155°F(68°C) Red (TY4851) 8.0 and 175°F(79°C) Yellow 1/2 in. Pendent1,2,3,4,5,6 N/A N/A NPT 1t 200°F(93°C) Green Figure 4 286°F(141°C) Blue •360°F(182°C) Mauve NOTES 1. Listed by Underwriters Laboratories,Inc.(UL). 2. Listed by Underwriters Laboratories,Inc.for use in Canada(C-UL). 3. Approved by FM Global(FM Approvals). 4. Approved by the Loss Prevention Certification Board(LPCB Ref.No.007k/03). 5. Approved by the City of New York under MEA 354-01-E- • 6. VdS Approved.(For details,contact Johnson Controls,Enschede,Netherlands,Tel.31-53-428-4444/Fax 31-53-428-3377) 7. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/05) 8. Where Polyester Coated,Lead Coated,Wax Coated,and Wax-over-Lead Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers,Where Lead Coated,Wax Coated,and Wax-over-Lead Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as Corrosion-Resistant Sprinklers. a. Installed with Style 10(1/2 in.NPT)or Style 40(3/4 in.NPT)3/4 in.Total Adjustment Recessed Escutcheon,as applicable b. 150'F(66"C)maximum ceiling temperature a. Frame and deflector only d. Not Applicable(N/A) TABLE C SERIES TY-B 8.0 K-FACTOR UPRIGHT AND PENDENT SPRINKLERS LABORATORY LISTINGS AND APPROVALS TFP151 Page 7 of 10 • Sprinkler Finish K-Factor Type Natural Chrome Lead Wax Wax-Over-Lead Brass Plated Polyesters Coated Coated Coated 2.8 Upright(TY1151) 1/2 in. and 175 psi(12,1 bar) N/A3 NPT Pendent(TY1251) Upright(TY3151) and 5.6 Pendent(TY3251) 250 psi(17,2 bar)2 1/2 in. or NPT 175 psi(12,1 bar) Recessed Pendent (TY3251) Upright(TY4151) and 175 psi(12,1 bar) 8.0 Pendent(TY4251) 3/4 in. NPT Recessed Pendent 175 psi(12,1 bar) N/A (TY4251) 8.0 Upright(TY4851) 1/2 in. and 175 psi(12,1 bar) NPT Pendent(TY4951) NOTES • 1. Frame and deflector only 2. The maximum working pressure of 250 psi(17,2 bar)only applies to the Listing by Underwriters Laboratories,Inc.(UL),the Listing by Underwriters Laboratories,Inc.for use in Canada(C-UL),and the Approval by the City of New York. 3. Not Applicable(N/A) TABLE D SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS MAXIMUM WORKING PRESSURE 0 TFP151 Page 8 of 10 Installation • Before wrench tightening the sprin- kler, adjust the jaws of the wrench Care and410 The TYCO Series TY-B 2.8, 5.6, and to contact only the sprinkler wrench Maintenance 8.0 K-factor, Upright, Pendent, and flats. Recessed Pendent Sprinklers must • After wrench tightening the sprin- The TYCO Series TY-B 2.8, 5.6, and be installed in accordance with this kler, loosen the wrench jaws before 8.0 K-factor, Upright, Pendent, and section. removing the wrench. Recessed Pendent Sprinklers must be General Instructions After Installation maintained and serviced in accordance Do not install any bulb type sprinkler After installation, complete the with this section. if the bulb is cracked or there is a loss following: Before closing a fire protection system of liquid from the bulb. With the sprin- • Inspect the sprinkler wrench flats main control valve for maintenance kler held horizontally,a small air bubble and frame arms and retouch (repair) work on the fire protection system should be present.The diameter of the the wax coating whenever the coat- that it controls, obtain permission to air bubble is approximately 1/16 in. ing has been damaged and bare shut down the affected fire protection (1,6 mm) for the 135°F (57°C) to metal is exposed. system from the proper authorities 3/32 in.(2,4 mm)for the 360°F(182°C) . Retouch the wax coating on the and notify all personnel who may be temperature ratings. wrench flats by gently applying a affected by this action. A leak-tight 1/2 in. NPT sprinkler heated 1/8 in. diameter steel rod The owner must assure that the sprin- joint should be obtained by apply- to the damaged areas of wax, to klers are not used for hanging any ing a minimum-to-maximum torque of smooth it back over areas where objects and that the sprinklers are only 7 to 14 lb-ft (9,5 to 19,0 N•m). Obtain bare metal is exposed. cleaned by means of gently dusting a leak-tight 3/4 in. NPT sprinkler joint with a feather duster; otherwise, non- by applying a minimum to maximum NOTICE operation in the event of a fire or inad- torque of 10 to 20 lb-ft (13,4 to Only retouching of the wax coating vertent operation may result. 26,8 N•m). Higher levels of torque may applied to the wrench flats and frame Absence of an escutcheon, which is distort the sprinkler inlet and cause arms is permitted, and the retouching used to cover a clearance, may delay leakage or impairment of the sprinkler. is to be performed only at the time of the time to sprinkler operation in a fire Do not attempt to compensate for the initial sprinkler installation. situation. insufficient adjustment in the escutch- The steel rod should be heated only to Sprinklers which are found to be eon plate by under- or over-tightening the point it can begin to melt the wax, leaking or exhibiting visible signs of the sprinkler. Readjust the position of and appropriate precautions need to be corrosion must be replaced. the sprinkler fitting to suit. taken when handling the heated rod in Series TY-B Upright and Pendent order to prevent the installer from being Automatic sprinklers coated, o must never other- Sprinklers Sprinklers Installation burned, paintedwise altered after leaving the factory. The Series TY-B Upright and Pendent Series TY-B Recessed Pendent Modified sprinklers must be replaced. Sprinklers must be installed in accor- Sprinklers Sprinklers that have been exposed to dance with the following instructions: The Series TY-B Recessed Pendent corrosive products of combustion,but Step 1.Install pendent sprinklers in the Sprinklers must be installed in actor- have not operated,should be replaced pendent position. Install upright sprin- dance with the following instructions: if they cannot be completely cleaned klers in the upright position. Step 1. After installing the Style 10 by wiping the sprinkler with a cloth or Step 2. With pipe thread sealant or 40 Mounting Plate, as applicable, by brushing it with a soft bristle brush. applied to the pipe threads, hand- over the sprinkler threads and with Care must be exercised to avoid tighten the sprinkler into the sprinkler pipe thread sealant applied to the pipe damage to the sprinklers before, fitting. threads, hand-tighten the sprinkler into during, and after installation. Sprin- the sprinkler fitting. klers damaged by dropping, strik- Step 3. Tighten the sprinkler into the Step 2. Tighten the sprinkler into the ing, wrench twist/slippage, or the like, sprinkler fitting using only the W-Type 6 Sprinkler Wrench, see Figure 7. sprinkler fitting using only the W-T must be replaced. Replace any sprin- For wax-coated sprinklers, use an Recessed Sprinkler Wrench,see Figure kler that has a cracked bulb or that has 8 or 10 in. adjustable wrench. With 8.With reference to Figure 3 or 4,apply lolost li Section.id from its bulb.See the Instal- reference to Figure 1 to 4, apply the the W-Type 7 Recessed Sprinkler W-Type 6 Recessed Sprinkler Wrench wrench to the sprinkler wrench flats. The owner is responsible for the or an adjustable wrench,as applicable, Step 3.After the ceiling is installed or inspection,testing,and maintenance of to the sprinkler wrench flats. the finish coat is applied, slide on the their fire protection system and devices Wax Coated Sprinklers Style 10 or 40 Closure over the Series in pliance wkh the applicable this document, standardsent, as When installingwax-coated sprinklers TY-B Recessed Pendent Sprinkler PP P and push the Closure over the Mount- of the National Fire Protection Associ- with an adjustable wrench,take care to ing Plate until its flange contacts the ation such as NFPA 25, in addition to prevent damage to the wax coating on ceiling' standards of any other authorities n the sprinkler wrench flats or frame arms g' having jurisdiction.Contact the install- and, consequently, exposure of bare ing contractor or product manufacturer metal to the corrosive environment: with any questions. • Open the jaws of the wrench suffi- Automatic sprinkler are recommended ciently wide to pass over the wrench to be inspected,tested,and maintained flats without damaging the wax by a qualified Inspection Service in coating. accordance with local requirements and/or national codes. TFP151 Page 9 of 10 • P/N 57 - XXX - X - XXX SIN SPRINKLER TEMPERATURE RATING FINISH 530 2.8K UPRIGHT(1/2 in.NPT) TY1151 1 NATURAL BRASS 135 135°F(57°C) 531 2.8K PENDENT(1/2 in.NPT) TY1251 POLY-STAINLESS GREY 155 155°F(68°C) 2 ALUMINUM(RAL9007)1 POLYESTER 175 175°F(79°C) 570 5.6K UPRIGHT(1/2 in.NPT) TY3151 PURE WHITE(RAL9010)2 3 POLYESTER 200 200°F(93°C) 571 5.6K PENDENT(1/2 In.NPT) TY3251 SIGNAL WHITE(RAL9003) 4 POLYESTER 286 286°F(141°C) 590 8.0K UPRIGHT(3/4 in.NPT) TY4151 JET BLACK(RAL9005)3 5 POLYESTER 591 8.0K PENDENT(3/4 in.NPT) TY4251 360 360°F(182°C) 6 WAX COATED 560 8.0K UPRIGHT(1/2 in.NPT) TY4851 286°F(141°C)MAX 000 OPEN4 7 LEAD COATED 561 8.0K PENDENT(1/2 in.NPT) TY4951 8 WAX-OVER-LEAD 286°F(141°C)MAX 9 CHROME PLATED NOTES 1. Only available on TY3151,TY3251,TY4151,and TY4251. • ino2. Eastern Hemisphere sales . 3. Available in only 8.0K, 155°F(68°C)or 200°F(93°C);requires lead time to manufacture. 4. Available only for 8.0 K-factor TY4151 end TY4251 for use in deluge systems("OPEN"indicates sprinkler assembly without glass bulb,button,and sealing assembly). TABLE E SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited OrderingWax Sticks(for retouching wrench- damaged wax coating) WarrantyProcedure Specify: (specify color, below) Color- coded Wax Sticks for retouching For warranty terms and conditions,visit Contact your local distributor for avail- (specify temperature rating) tempera- www.tyco-fire.com. ability.When placing an order, indicate ture-rated Series TY-B Sprinklers, P/N the full product name and Part Number (specify) (P/N). Black for 135°F(57°C) P/N 56-065-1-135 Red for 155°F(68°C) P/N 56-065-1-155 Sprinkler Assemblies with Yellow for 175°F(79°C) P/N 56-065-1-175 NPT Thread Connections Blue for 200°F(93°C) Specify: Series TY-B (specify SIN), and 286°F(141°C) P/N 56-065-1-286 (specify K-factor), (specify Upright Note: Each wax stick is suitable for or Pendent) Sprinkler with (specify) retouching up to 25 sprinklers. temperature rating, (specify) finish or The wax used for 286°F(141°C)sprinklers coating, P/N (See Table E) is the same as for 200°F(93°C)sprinklers. Recessed Escutcheon Therefore, the 286°F (141°C) sprinkler Specify: Style (10 or 40) Recessed is limited to the same maximum ceiling Escutcheon with (specify`) finish, P/N temperature as the 200°F(93°C)sprinkler (specify`) which is 150°F(66°C). •Refer to Technical Data Sheet TFP770 Sprinkler Wrenches Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 • Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 CO� Worldwide Contacts www.tyco-fire.com • ty Series DS-1 - 5.6 K-factor, Dry-type Sprinklers Pendent, Upright, and Horizontal Sidewall Standard Response, Standard Coverage General NOTICE Series DS-1 Dry-type Sprinklers t Description described herein must be installed and maintained in compliance with this TYCO Series DS-1 5.6K Pendent, document,as well as with the applica- Upright,and Horizontal Sidewall,Stan- ble standards of the NATIONAL FIRE dard Response(5 mm bulb),Standard PROTECTION ASSOCIATION (NFPA), Coverage Dry-type Sprinklers are dec in addition to the standards of any other orative glass bulb automatic sprinklers authorities having jurisdiction. Failure typically used where: to do so may impair the performance I • pendent sprinklers are required of these devices. q on dry pipe systems that are The owner is responsible for main- exposed to freezing temperatures taining their fire protection system (for example, sprinkler drops from and devices in proper operating con- ill, , unheated portions of buildings) dition. Contact the installing contrac- • sprinklers and/or a portion of the for or product manufacturer with any connecting piping may be exposed questions. to freezing temperatures (for Series DS-1 Dry-type Sprinklers must 410 example, sprinkler drops from wet only be installed in fittings that meet systems into freezers, or horizontal the requirements of the Design Crite- piping extensions through a wall to ria section. protect unheated areas of a building such as loading docks,overhangs, Sprinkler and building exteriors) • sprinklers are used on systems that Identification/ -t are seasonably nably drainedto avoid Numbers (SINS)freezing (for example, vacation resort areas) TY3255-Pendent TY3155-Upright TY3355-Horizontal Sidewall Discharge Coefficient Technical K=5.6 gpm/psis(80.6 1pm Ipm/bares) Data Temperature Ratings See Tables A and B. Approvals Finishes UL and C-UL Listed Sprinkler:See Table D. FM Approved Escutcheon:See Table D. NYC Approved Physical Characteristics • under MEA 352-01-E Inlet Copper IMPORTANT LPCB Approved Plug Copper Refer to Technical Data Sheet • Reference No.094a/11 Yoke Stainless Steel TFP2300 for warnings pertaining to CE Certified Casing Galvanized Carbon Steel Insert Bronze regulatory and health information. • Certificate of Conformity Bulb Seat Stainless Steel Always refer to Technical Data No.2831-CPR-S2015 Bulb(5 mm dia.) Glass Sheet TFP700 for the "INSTALLER See Tables A and B for details. Compression Screw Bronze WARNING" thatprovides cautionsWorking Deflectore Bronze Maximum Pressure Frame Bronze with respect to handling and instal- 175 psi(12,1 bar) Guide Tube Stainless Steel lation of sprinkler systems and coin- Inlet Thread Connections Water Tube Stainless Steel • ponents. Improper handling and Spring Stainless Steel installation can permanently damage nR 1 N Sealing Assembly..Beryllium Nickel w/TEFLON a sprinkler system or its compo- Escutcheon....Carbon Steel or Stainless Steel nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 SEPTEMBER 2021 TFP500 TFP500 Page 2 of 10 SPRINKLER ESCUTCHEON TEMPERATURE BULB SPRINKLER FINISH • TYPE TYPE RATING COLOR CODE NATURAL CHROME POLYESTER* BRASS PLATED 135°F(57°C) Orange 155°F(68°C) Red 175°F(79°C) Yellow 1,2,3,4,5 1,2,4,5 STANDARD 200°F(93°C) Green 286°F(141°C) Blue 360°F(182°C) Mauve 1,2,3 1,2 135°F(57°C) Orange 155°F(68°C) Red 175°F(79°C) Yellow 1,2,3,5 1,2,5 RECESSED 200°F(93°C) Green 286°F(141°C) Blue 1,2 PENDENT 360°F(182°C) Mauve N/A (TY3255) 135°F(57°C) Orange 155°F(68°C) Red 175°F(79°C) Yellow DEEP 200°F(93°C) Green 286°F(141°C) Blue 360°F(182°C) Mauve 1,2,3,4,5 1, 2,4,5 135°F(57°C) Orange 155°F(68°C) Red WITHOUT 175°F(79°C) Yellow 200°F(93°C) Green 286°F(141°C) Blue 360°F(182°C) Mauve 1,2,3 1,2 135°F(57°C) Orange 155°F(68°C) Red UPRIGHT 175°F(79°C) Yellow 1,2,3,4,5 1,2, 4,5 (TY3155) WITHOUT 200°F(93°C) Green 286°F(141°C) Blue 360°F(182°C) Mauve 1,2,3 1,2 Notes: 1. Listed by Underwriters Laboratories,Inc.(UL),maximum order length of 48 in. 2. Listed by Underwriters Laboratories for use in Canada(C-UL),maximum order length of 48 in. 3. Approved by FM Global(FM Approvals),maximum order length of 48 in. 4. Loss Prevention Certification Board(LPCB)and CE conformity apply to these temperature ratings only 5. Approved by the City of New York under MEA 352-01-E Frame and deflector only N/A-Not Applicable TABLE A SERIES DS-1 PENDENT& UPRIGHT DRY-TYPE SPRINKLERS, 5.6K, STANDARD RESPONSE LABORATORY LISTINGS AND APPROVALS TFP500 Page 3 of 10 SPRINKLER FINISH • SPRINKLER ESCUTCHEON TEMPERATURE BULB TYPE TYPE RATING COLOR CODE NATURAL CHROME POLYESTER*** BRASS PLATED 135°F(57°C) Orange 155°F(68°C) Red 175°F(79°C) Yellow STANDARD 200°F(93°C) Green 286°F(141°C) Blue 360°F(182°C) Mauve 135°F(57°C) Orange 155°F(68°C) Red HSW" 175°F(79°C) Yellow 1** 2",3*** 4,5 P*,2**,4,5 (TY3355) DEEP 200°F(93°C) Green 286°F(141°C) Blue 360°F(182°C) Mauve 135°F(57°C) Orange 155°F(68°C) Red 175°F(79°C) Yellow WITHOUT 200°F(93°C) Green 286°F(141°C) Blue 360°F(182°C) Mauve 1",2'",5 1** 2** Notes: 1. Listed by Underwriters Laboratories,Inc.(UL),maximum order length of 48 In. 2. Listed by Underwriters Laboratories for use in Canada(C-UL),maximum order length of 48 in. 3. Approved by FM Global(FM Approvals),maximum order length of 48 in, 4. Loss Prevention Certification Board(LPCB)and CE conformity apply to these temperature ratings only 5. Approved by the City of New York under MEA 352-01-E Horizontal sidewall with top of deflector-to-ceiling distance of 4 to 12 In.(100 to 300 mm) Light and ordinary hazard occupancies only — Light hazard occupancies only "" Frame and deflector only TABLE B SERIES DS-1 HORIZONTAL SIDEWALL(HSW) DRY-TYPE SPRINKLER, 5.6K, STANDARD RESPONSE LABORATORY LISTINGS AND APPROVALS PLUG WITH 9" --- INLET SEALING lirASSEMBLY if WRENCH E YOKE RECESS ■r� SPRING t/ �i%.��; INLET • ` BAND WATER WRENCH O TUBE 1 CASING FLAT a GUIDE k il Z INSERT PUSH WRENCH TUBE -11 IN TO ENSURE ` ENGAGEMENT BULB WITH SPRINKLER FRAME � 'i `� SEAT WRENCHING AREA t r FIGURE 2 «( W-TYPE 7 VENT HOLE *RI 5 mm BULB WRENCH rI COMPRESSION . DEFLECTOR �.� SCREW FIGURE 1 SERIES DS-1 DRY-TYPE SPRINKLER, 5.6K, STANDARD RESPONSE ASSEMBLY TFP500 Page 4 of 10 SPRINKLER FITTING SPRINKLER FITTING SPRINKLER FITTING (REFER TO DESIGN (REFER TO DESIGN (REFER TO DESIGN • CRITERIA SECTION) CRITERIA SECTION) CRITERIA SECTION) FACE OF FACE OF FACE OF \ SPRINKLER SPRINKLER SPRINKLER \ FITTING FITTING FITTING }}} \ L_ _2 \ 1. \ _L_ JI ORDER LENGTHS: ORDER LENGTHS: ORDER LENGTHS: 3-1/2"DIA. 2-3/4"to 48" 1-3/4"DIA. 3-3/4"to 48" 1/2°to 46" (88,9 mm) (69,9 to 1219,2 mm) (44,5 mm) (95,3 to 1219,2 mm) (12,7 to 1168,4 mm) 2 11/2"DIA. IN 1/4"(6,4 mm) IN 1/4"(6,4 mm) 2-1/4"DIA. IN 1/4"(6,4 mm) 3,5 mm)-IINCREMENTS INCREMENTS (57,2 mm) INCREMENTS ni FACE OF % I III . �d' --- CEILING FACE OF _� FACE OF CEILING I _u W CEILING ,�"1 4-1/4"±1/8" — (108,0±3,2 mm) 2-3/16"±1/8" 3" DIA. 1-3/8"±1/8" 2-7/8" DIA. ' ' (55,6±3,2 mm) ,(76,2 mm) (34,9±3,2 mm) (73,0 mm) ! 11_ FIGURE 4 FIGURE 3 PENDENT(TY3255) FIGURE 5 PENDENT(TY3255) WITH STANDARD PENDENT(TY3255) WITH STANDARD ESCUTCHEON RECESSED ESCUTCHEON WITH DEEP ESCUTCHEON SPRINKLER FITTING / (REFER TO DESIGN TOP OF CRITERIA SECTION) DEFLECTOR FACE OF } •SPRINKLER FITTING \ L- ORDER LENGTHS: t 5'to 48" (127,0 to 1219,2 mm) ORDER LENGTHS: IN 1/4"(6,4 mm) 5"to 48" INCREMENTS (127,0 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS FACE OF 1 SPFITTINGRINKLER MINIMUM \ ,- 1-3/4"(44,5 mm) /"DEFLECTOR TO CEILING SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FIGURE 6 FIGURE 7 PENDENT(TY3255) UPRIGHT(TY3155) WITHOUT ESCUTCHEON WITHOUT ESCUTCHEON • TFP500 Page 5 of 10 • ORDER LENGTHS: Operation 2-3/4"to 48"(69,9 to 1219,2 mm) IN 1/4"(6,4 mm)INCREMENTS 2 3/8" 1/8" When TYCO Series DS-1 5.6K Pendent, I (60,3±3,2 mm) Upright,and Horizontal Sidewall,Stan- FACE OF FACE OF dard Response, Standard Coverage SPRINKLER MOUNTING Dry-type Sprinklers are in service, FITTING SURFACE water is prevented from entering the N assembly by the Plug with Sealing IAssembly(see Figure 1) in the Inlet of �II�I������P� _ 1 the sprinkler. I �I_ DIA. glass The bulb contains a fluid that expands when exposed to heat.When 3.5° the rated temperature is reached, the 1-3/4"DIA. SI fluid expands sufficiently to shatter (REFER TO DESIGN CENTERLINE 5/16" SPRINKLER FITTING (44,5 mm) \ the glass bulb, and the Bulb Seat is CRITERIA SECTION) OF WATERWAY (7,9 mm) released. FIGURES The compressed Spring is then able HORIZONTAL SIDEWALL(TY3355) to expand and push the Water Tube as WITH STANDARD ESCUTCHEON well as the Guide Tube outward. This action simultaneously pulls inward on the Yoke, withdrawing the Plug with ORDER LENGTHS: Sealing Assembly from the Inlet,allow- 1/2"to 45-3/4"(12,7 to 1162,1 mm) ing the sprinkler to activate and flow IN 1/4"(6,4 mm)INCREMENTS water. I _ 4-1/4"±1/8" 2-1/2"DIA. FACE OF (108,0±3,2 mm) Design FACE OF (63,5 mm) MOUNTING SPRINKLER SURFACE Criteria FITTING 1 TYCO Series DS-1 5.6K Pendent, Upright,and Horizontal Sidewall,Stan- dard Response, Standard Coverage (���������������,1 �11: (88,9 mm) Dry-type Sprinklers are intended for • ' � �1L� / 3.5° T use in fire sprinkler systems designed SPRINKLER FITTING O in accordance with the standard instal- (REFER TO DESIGN CENTERLINE 5/16" lation rules recognized by the appli- CRITERIA SECTION) OF WATERWAY (7,9 mm) cable listing or approval agency (for example, UL Listing is based on NFPA FIGURE 9 13 requirements). For more information HORIZONTAL SIDEWALL(TY3355) on LPCB Approval, contact Johnson WITH DEEP ESCUTCHEON Controls at the following office: Kopersteden 1 ORDER LENGTHS: 7547 TJ Enschede 5-1/2"to 48"(139,7 to 1219,2 mm) - The Netherlands IN 1/4"(6,4 mm)INCREMENTS MINIMUM Tel: +31-(0)53-428-4444 2-1/4"(57,2 mm) Fax: +31-(0)53-428-3377 FACE OF DEFLECTOR TO Sprinkler Fittings SPRINKLER MOUNTING Install 1 in. NPT Series DS-1 Dry-type FITTING SURFACE Sprinklers in the 1 in.NPT outlet or run of the following fittings: • malleable or ductile iron threaded --_,ey: r tee fittings that meet the imen- / sional requirements of ANSI B16.3 -, 3.5°\ 5/16" (Class 150) SPRINKLER FITTING (7,9 mm) • cast iron threaded tee fittings that (REFER TO DESIGN CENTERLINE meet the dimensional requirements CRITERIA SECTION) OF WATERWAY of ANSI B16.4(Class 125) FIGURE 10 Do not install Series DS-1 Dry-type HORIZONTAL SIDEWALL (TY3355) Sprinklers into elbow fittings.The Inlet WITHOUT ESCUTCHEON of the sprinkler can contact the interior of the elbow. The unused outlet of the threaded tee is• plugged as shown in Figure 12. TFP500 Page 6 of 10 Temperatures for Heated Area(1) Drainage • In accordance with the minimum Ambient Temperature 40°F 50°F 60°F requirements of the NATIONAL FIRE Exposed to (4°C) (10°C) (16°C) PROTECTION ASSOCIATION for dry Discharge End of Sprinkler Minimum Exposed Barrel Length(z), pipe sprinkler systems, branch, cross, and feed-main piping connected to Dry in. Sprinklers and subject to freezing tem- (f1f11) peratures must be pitched for proper 40°F 0 0 0 drainage. (4°C) Exposure Length 30°F 0 0 0 When using Dry Sprinklers in wet pipe (-1°C) sprinkler systems to protect areas 20°F 4 subject to freezing temperatures, use (-7°C) (100) 0 0 Table C to determine a sprinkler's o°F 8 1 appropriate exposed barrel length to 1 (-10 con- (-12°C) (200) (25)10 prevent water from freezing in the con- necting pipes due to conduction. The 0°F 12 3 exposed barrel length measurement (-18°C) (305) (75) 0 must be taken from the face of the 10°F 14 4 1 sprinkler fitting to the surface of the (-23°C) (355) (100) (25) structure or insulation that is exposed to the heated area. See Figure 11 for -20°F 14 6 3 an example. (-29°C) (355) (150) (75) For protected area temperatures -30°F 16 8 4 between those given above, the (-34°C) (405) (200) (100) minimum recommended length from 40°F 18 8 4 the face of the fitting to the outside of (-40°C) (455) (200) (100) the protected area may be determined by interpolating between the indicated -50°F 20 10 6 values. (-46°C) (510) (255) (150) Clearance Space -60°F 20 10 6 (-51°C) (510) (255) (150) connecting ng an with b 13, when an area subject to freez- Notes: ing and an area containing a wet pipe 1. For protected area temperatures that occur between values listed above,use the next cooler temperature. sprinkler system,the clearance space 2. These lengths are inclusive of wind velocities up to 30 mph(18,6 kph). TABLE C around the sprinkler barrel of dry-type em- EXPOSED SPRINKLER BARRELS IN WET PIPE SYSTEMS sprinklers differences mf t b cesled. Due to ttwo MINIMUM RECOMMENDED LENGTHS areas, th ontialfbetweenefrtwo areas, the potential for the formation of condensation in the sprinkler and You can also install Series DS-1 Dry- For dry pipe system installations, subsequent ice build-up is increased.If type Sprinklers in the 1 in. NPT outlet use only the side outlet of maximum this condensation is not controlled,ice of a GRINNELL Figure 730 Mechanical 2 1/2 in. reducing tee when locat- build-up can occur that might damage Tee and GRINNELL G-FIRE Figure 522; ing Series DS-1 Dry-type Sprinklers the dry-type sprinkler and/or prevent however,the use of the Figure 730 Tee directly below the branchline; other- proper operation in a fire situation. and Figure 522 for this arrangement is wise, use the configuration shown in Use of the Model DSB-2 DrySprinkler limited to wet pipe systems. Figure 12 to assure complete water P drainage from above Series DS-1 Boot,described in technical data sheet The configuration shown in Figure 13 Dry-type Sprinklers and the branch- TFP591 and shown in Figures 14 and is only applicable for wet pipe systems line. Failure to do so may result in pipe 15,can provide the recommended seal. where the sprinkler fitting and water- freezing and water damage. filled pipe above the sprinkler fitting are not subject to freezing and where the length of the dry-type sprinkler has NOTICE the minimum exposure length depicted Do not install Series DS-1 Dry-type in Figure 11. See the Exposure Length Sprinklers into any other type fitting. section. Failure to use the appropriate fitting For wet pipe system installations of may result in one of the following: 1 in. NPT Series DS-1 Dry-Type Sprin- • failure of the sprinkler to operate klers connected to CPVC piping, use properly due to formation of ice only the following TYCO CPVC fittings: over the Inlet Plug or binding of the • 1 in. x 1 in. NPT Female Adapter Inlet Plug (P/N 80145) • insufficient engagement of the • 1 in.x 1 in.x 1 in.NPT Sprinkler Head Inlet pipe-threads with consequent Adapter Tee(P/N 80249) leakage1111 TFP500 Page 7 of 10 • __ _ RUN FACE OF OUTLET TO WET SIDE SPRINKLER _ E-PLUGGED SYSTEM OUTLET 9!)FITTING -1 SPRINKLER PLUGGED FITTING HEATED HEATED EXPOSURE TO DRY (SEE DESIGN AREA LENGTH SYSTEM CRITERIA AREA (SEE DESIGN SECTION) DSB-2 CRITERIA AREA DSB-2 SPRINKLER INTENDED SECTION) SUBJECT DSB-2 FITTING INTENDED INTENDED FOR FREEZER TOFOR FREEZER (SEE DESIGN STRUCTURES FREEZING FOR FREEZER STRUCTURES CRITERIA STRUCTURES SECTION) FIGURE 12 FIGURE 13 FIGURE 11 SPRINKLER FITTING SPRINKLER FITTING EXPOSURE LENGTH UNHEATED AREA HEATED AREA STRAP TIES 1-3/4" DIA. p (ENDS ON (44,5 mm) OPPOSING CLEARANCE INSULATED SIDES OF HOLE FREEZER BOOT) ADHESIVE STRUCTURE DSB-2 BOOT , No •Ii DSB-2 ADHESIVE BOOT I . 1-3/4" DIA. 1� (44.5 mm) ihmry4it7�1l� 1 CLEARANCE HOLE 1� NSULATED t / FREEZER 1 / STRUCTURE STRAP TIES Mil DS-1 (ENDS ON DS-1 SHOWN WITH II ---`_SHOWN WITH OPPOSING STANDARD STANDARD SIDES OF ESCUTCHEON ESCUTCHEON BOOT) FIGURE 14 FIGURE 15 MODEL DSB-2 DRY SPRINKLER MODEL DSB-2 DRY SPRINKLER BOOT WITH PENDENT SERIES BOOT WITH SIDEWALL SERIES DS-1 DRY-TYPE SPRINKLER DS-1 DRY-TYPE SPRINKLER TFP500 Page 8 of 10 Installation Note: If sprinkler removal becomes have not operated,should be replaced necessary, remove the sprinkler using if they cannot be completely cleaned TYCO Series DS-1 5.6K Pendent, the same wrenching method noted by wiping the sprinkler with a cloth or Upright,and Horizontal Sidewall,Stan- above.Sprinkler removal is easier when by brushing it with a soft bristle brush. a non-hardening sealant was used dard Response, Standard Coverage Care must be exercised to avoid Dry-type Sprinklers must be installed and torque guidelines were followed. damage to the sprinklers before, in accordance with this section. After removal, inspect the sprinkler for during, and after installation. Sprin- damage. klers damaged by dropping, striking, General Instructions Step 3. After installing the ceiling or wrench twist/slippage,or the like,must Series DS-1 Dry-type Sprinklers must wall and applying a ceiling finish,slide be replaced.Also,replace any sprinkler only be installed in fittings that meet on the outer piece of the escutch- that has a cracked bulb or that has lost the requirements of the Design Cri- eon until it comes in contact with the liquid from its bulb.See the Installation teria section. See the Design Criteria ceiling/wall. Do not lift the ceiling panel section. section for other important require- out of its normal position. ments regarding piping design and The owner is responsible for the sealing of the clearance space around When using the Deep Escutcheon, inspection,testing,and maintenance of the Sprinkler Casing. hold the outer piece in contact with the their fire protection system and devices DDo not any sprinkler mounting surface(ceiling or wall).Then in compliance with this document, as o the install bulb-typeo thereis a loss rotate the inner piece approximately 1/4 well as with the applicable standards if bulbiscracked bulb. is sprin- turn with respect to the outer piece, of the NATIONAL FIRE PROTECTION oof liquid fromo he horizontally, small With air to hold the Deep Escutcheon firmly ASSOCIATION, such as NFPA 25, in kler helde be present.onta The diameter bubbleo the together. addition to the standards of any other shoair bubble is approximately 1/16 in. authorities having jurisdiction.Contact (1,6 mm)for the 135°F(57°C) rating to Care and the installing contractor or product 1/8 in. (3,2 mm)for the 360°F(182°C) manufacturer with any questions. rating. Maintenance Automatic sprinkler systems are rec- ommended to be inspected, tested, Obtain a leak-tight 1 in. NPT sprinkler TYCO Series DS-1 5.6K Pendent, and maintained by a qualified Inspec- joint by applying a minimum-to-maxi- Upright, and Horizontal Sidewall, tion Service in accordance with local mum torque of 20 to 30 lb-ft (26,8 to Standard Response, Standard Cover- requirements and/or national codes. 40,2 N•m). Higher levels of torque may age Dry-type Sprinklers must be main- distort the sprinkler Inlet with conse- tained and serviced in accordance with quent leakage or impairment of the this section. • sprinkler. Before closing a fire protection system Do not attempt to compensate for main control valve for maintenance insufficient adjustment in an Escutch- work on the fire protection system eon Plate by under or over-tightening that it controls, obtain permission to the Sprinkler. Re-adjust the position of shut down the affected fire protection the sprinkler fitting to suit. systems from the proper authorities Notes: and notify all personnel who may be • Install pendent sprinklers only in affected by this action. the pendent position;install upright Absence of the outer piece of an sprinklers only in the upright posi- escutcheon, which is used to cover a tion. The deflector of a pendent or clearance hole, may delay the time to upright sprinkler is to be parallel to sprinkler operation in a fire situation. the ceiling. A Vent Hole is provided in the Bulb • Install horizontal sidewall sprinklers Seat(see Figure 1)to indicate if the Dry in the horizontal position with their Sprinkler is remaining dry. Evidence of centerline of waterway perpendicu- leakage from the Vent Hole indicates lar to the back wall and parallel to potential leakage past the Inlet seal the ceiling. Ensure the word "TOP" and the need to remove the sprinkler on the Deflector faces the ceiling. to determine the cause of leakage; Step 1. With a non-hardening pipe- for example, an improper installation thread sealant such as TEFLON applied or an ice plug. Close the fire protec- to the inlet threads, hand-tighten the tion system control valve and drain the sprinkler into the sprinkler fitting. system before removing the sprinkler. Step 2. Wrench-tighten the sprinkler Sprinklers which are found to be using either: leaking or exhibiting visible signs of • a pipe wrench on the Inlet Band or corrosion must be replaced. the Casing, see Figure 1 Automatic sprinklers must never be • the W-Type 7 Sprinkler Wrench on painted, plated, coated, or other- the Wrench 7Fl see Figure 2 wise altered after leaving the factory. Modified sprinklers must be replaced. Apply the wrench recess of the W-Type Sprinklers that have been exposed to • 7 Sprinkler Wrench to the wrench flat. corrosive products of combustion, but TFP500 Page 9 of 10 • P/N* 60 - XXX - X - XXX SPRINKLER ESCUTCHEON SIN FINISH FINISHI1) Pendent with TY3255 SIGNAL WHITE 96 Standard Escutcheon(1 in.NPT) (Figure 3) 0 PLAT (RAL9003) ED Pendent with TY3255 POLYESTER 93 Deep Escutcheon(1 in.NPT) (Figure 5) SIGNAL WHITE NATURAL (RAL9003) 97 Pendent with TY3255 1 BRASS POLYESTER Recessed Escutcheon(1 in.NPT) (Figure 4) Pendent without TY3255 NATURAL BRASS 92 Escutcheon(1 in.NPT) (Figure 6) 2 BRASS PLATED Sidewall with TY3355 SIGNAL WHITE SIGNAL WHITE 94 4 (RAL9003) (RAL9003) Standard Escutcheon(1 in.NPT) (Figure 8) POLYESTER POLYESTER Sidewall with TY3355 53 Deep Escutcheon(1 in.NPT) (Figure 9) 8 CHROME STAINLESS PLATED STEEL 54 Sidewall without TY3355 Escutcheon(1 in.NPT) (Figure 10) 9 CHROME CHROME PLATED PLATED 98 Upright without TY3155 Escutcheon(1 in.NPT) (Figure 7) TEMPERATURE ORDER RATING(2) LENGTH(a1 Notes: 1. Escutcheon Finish applies to sprinklers provided with escutcheons. 0 135°F(57°C) 055 5.50 in. 2. 360°F(182°C)temperature rating applies to non-recessed sprinkler • assemblies. 3. Dry-type Sprinklers are furnished based upon"Order Length"as mea- sured per Figures 3 through 10,as applicable,and for each individual sprinkler where it is to be installed.After the measurement is taken, 2 175°F(79°C) 180 18.00 in. round it to the nearest 1/4 in.increment. • Use Prefix"I"for ISO 7-R 1 Connection(for example,1-60-961-1-180). 3 200°F(93°C) 187 18.75 in. 4 286°F(141°C) 372 37.25 in. 5 360°F(182°C) 480 48.00 in. TABLE D SERIES DS-1 DRY-TYPE SPRINKLERS, 5.6K, STANDARD RESPONSE PART NUMBER SELECTION TFP500 Page 10 of 10 Limited • Order Length: Replacement Escutcheons Dry-type Sprinklers are furnished Order replacement escutcheons Warrantybased upon Order Length as mea- separately. sured per Figures 3 through 10, as Note:Style 10 Recessed Escutcheons For warranty terms and conditions,visit applicable.After the measurement is are shipped as assemblies comprised www.tyco-fire.com. taken, round it to the nearest 1/4 in. of closure ring and mounting plate. The increment. included mounting plate is not used Ordering • Inlet Connections: for Dry Type Sprinkler applications, 1 in.NPT discard accordingly. Procedure (Standard) Specify:(specify type),(specify)finish, ISO 7-R 1 P/N(specify): Contact your local distributor for avail- (For information on ISO Inlet Thread Recessed(Style 10) ability. When placing an order, indi- Connections, contact your Johnson Brass Plated 56-701-2-010 cate the full product name, including Controls Sales Representative.) Signal White(RAL9003) 56-701-4-010 description and part number(P/N). . Temperature Rating Chrome Plated 56-701-9-010 Dry-type Sprinklers • Sprinkler Finish Standard(Push-On) When ordering Series DS-1 5.6K p White Color 91-106-0-007 Pendent,Upright,and Horizontal Side- • Escutcheon Type and Finish, as Brass Plated 91-108-2-007 wall, Standard Response, Standard applicable Chrome Plated 91-106-9-007 Coverage Dry-type Sprinklers,specify P/N from Table D Deep the following information: Brass Plated 91-107-2-010 Part numbers are for 1 in. NPT stan- White 91-107-4-007 • SIN: dard order sprinklers. Orders for Chrome Plated 91-107-9-007 TY3255-Pendent all other sprinkler assemblies must Sprinkler Wrench TY3155- Upright be accompanied by a complete Specify W-Type 7 Sprinkler Wrench, TY3355-Horizontal Sidewall description. P/N 56-850-4-001 Sprinkler Boot Specify Model DSB-2 Dry Sprinkler Boot, P/N 63-000-0-002 This part number includes one(1)Boot, two(2)Strap Ties,and 1/3 oz of Adhe- sive (a sufficient quantity for installing fi one boot). • 1400 Pennbrook Parkway,Lansdale,PA 194461 Telephone+l-215-362.0700 j o 2021 Johnson Controls.All rights reserved.All speclticallon.end other information shown were current se of document revision date end are subject to duns.',Mhos.notice. Johnson aii, NATIONAL FIRE PROTECTION ASSOCIATION and NFPAare reclelered trademarks of National Fire Protector Association; Controls TEFLON its batlemarklO el The Cmoure Company FC,LLC