HomeMy WebLinkAboutReport PATRIOT 4708 NE MINNEHAHA ST VANCOUVER,WA 98661 FIRE PROTECTION INC. Fire Sprinklers Save Lives! TEL(360)699-4403 FAX(360)699-4485 • ooN . Terrace Glen Apartments 9640 SW Greenburg Road Portland, Oregon RECEIVED FEB 2 202t CITY OF TIGARD BUILDING DIVISION Fire Sprinkler System Material Submittal • JOB # 31-1530 November 12, 2021 • TACOMA,WA OFFICE ken.kem@patriotfire.com SPOKANE,WA OFFICE TEL(253)926-2290 PATRIFP�9CF/CCB70822 TEL(509)926-3428 FAX(253)922-6150 FAX(509)926-3708 PRODUCT SUBMITTAL Fire Protection • Terrace Glen Apartments 9640 SW Greenburg Road Portland, Oregon Fire Suppression Sprinkler System- 1. Fire Protection Pipe and Fittings: a) Piping 1-1/2"—8" (Sch. 10-grooved): Import, Black Steel /State Pipe and Supply Co. b) Piping 1"—2" (Sch. 40-threaded): Import, Black Steel/State Pipe and Supply Co. c) In-building riser; Ames Fire and Waterworks (Watts Brand) d) Welded Outlets and Nipples (grooved/threaded): Cooper; Smith Cooper International e) Couplings and Fittings (grooved): Tyco Fire & Building Products f) Fittings (threaded): Star Pipe Products; Anvil International g) CPVC Piping and Fittings; TYCO Fire & Building Products; Blazemaster 2. Fire Protection Control Valve: a) 2-1/2"-8" Grooved End Butterfly Valve; Reliable Automatic Sprinkler Co. Mod. REL-BFG-300 w/ Tamper Switch b) 2"-12" Grooved End Swing Check Valve; Tyco Fire and Building Products Mod. CV-1F c) Commercial Riser Manifold; Tyco Fire Protection Products; Mod. CR d) 2"-6" Grooved End Dry Pipe Valve; TYCO Fire Products; Mod. DPV-1 w/Standard Trim e) Automatic Air Maintenance Device; TYCO Fire Products; Model AMD-1; Field Adjustable Pressure Regular f) 2"Test and Drain; AGF Manufacturing Inc.; Mod. 1011 T w/Pressure Relief Valve g) 2- Y2" Fire Hose Valves, Zurn Mod F100G; Grooved Cast Brass Finish w/Cap and chain • 3. Fire Protection Electrical: a) 10" Electric Bell; Potter Electric; Mod. PBA-AV 24v b) Vane Type Waterflow Alarm Switch w/ Retard; Potter Electric; Mod. VSR c) Pressure Switch; Potter Electric; Mod. PS10 d) Supervisory Pressure Switch; Potter Electric; Mod. PS-40 e) Dry Pipe Air Compressor; C-Aire, Mod. (to be determined) 4. Fire Protection Sprinklers: a) Quick Response Upright Sprinkler: Reliable Automatic Sprinkler Co. Mod. KFR56 K=5.6, 200°, '/2" n.p.t.; Bronze Finish Sin# RA3624 b) Quick Response Pendent Sprinkler: Reliable Automatic Sprinkler Co. Mod. KFR56 K=5.6, 155°, ''/2" n.p.t.; White Finish w/White Esc.; Sin# RA3614 c) Quick Response Concealed Pendent Sprinkler: Reliable Automatic Sprinkler Co. Mod. Model G5 Series K=5.6, 155°, '/2" n.p.t.; White Finish w/White Cover Plate; Sin# RA3415 d) Quick Response HSW Sprinkler: Reliable Automatic Sprinkler Co. Mod. KFR56 K=5.6, 155°, '/2" n.p.t.; Brass; White Finish w/White Esc.; Sin# RA3634 e) Standard Response Attic Space Upright Sprinkler: Reliable Automatic Sprinkler Co. Mod. Attic series K=5.6, 212°, '/2" n.p.t.; Bronze Finish Sin# (varies) f) Residential Sprinklers for Design Density of.10 gpm/sqft.; Reliable Automatic Sprinkler Co.; Mod. RFC49 Concealed SSP, K=4.9; 155°, '/2" n.p.t.; Brass Finish w/White Cover Plate Sin# RA0616 • g) Residential Sprinklers for Design Density of.10 gpm/sqft.; Reliable Automatic Sprinkler Co.; Mod. KRES44 Res. HSW, K=4.4; 155°, '/2" n.p.t.; White Finish w/White Esc. Sin# R3591 h) Dry Quick Response Standard Spray Sprinkler; Reliable Automatic Sprinkler Co.; Mod. F3QR56, K=5.6, 155°, 1" n.p.t.; Chrome Finish w/Chrome Esc. Sin# R5714 i) Fire Sprinkler Escutcheon; Reliable Automatic Sprinkler Co.; Model F1/F2 Two piece White Finish Fire Suppression System- (cont.) j) Sprinkler Emergency Cabinet: Reliable Automatic Sprinkler Co. Mod. A4 6 Capacity Standard • k) Sprinkler Wrenches; Reliable Automatic Sprinkler Co. I) Sprinkler Guards; Reliable Automatic Sprinkler Co. m) Flexible Hose; FlexHead Industries 5. Misc.: a) Signs; FPPI b) One Step Solvent Cement; TYCO Fire Protection Products; TFP-500 6. Fire Protection Hangers and Seismic Bracing: a) Hanger and attachments: Tolco and Speedy Products b) Seismic attachments: Tolco c) CPVC Hangers; Tolco/Cooper B-line 7. Fire Protection Fire Stopping: a) One-part acrylic-based sealant; Hilti Inc.; FS-One High Performance Intumescent Firestop Sealant b) ER-5071 ES report; Hilti Firestop systems for through penetrations. • • • 1 Fire Protection Pipe and Fittings • • State Pipe & Supply, Inc. THIS INFORMATION PROVIDED IS BASED ON ASTM GUIDELINES FOR WELDED PIPE SPECIFICATIONS AND ASTM REQUIREMENTS. ACTUAL PIPE AND MATERIAL TEST REPORTS PROVIDED WOULD MEET OR EXCEED THESE GUIDELINES. TEST REPORTS WOULD PROVIDE SPECIFIC AND ACTUAL DETAILS CONCERNING THE MECHANICAL AND CHEMICAL PROPERTIES OF THE ACTUAL PIPE,AS WELL AS ADDITIONAL TESTS RESULTS REQUIRED BY ASTM. SCHEDULE 10 -- Black and Galvanized Steel ERW Pipe Pipe Size Test Pressure Nominal O D. I.D. Weight/Foot psi 1" 1.315 1.097 1.410 700 1-1/4" 1-660 1.442 1.810 1200 1-112" 1.900 1.682 2.090 1200 2" 2.375 2.157 2.640 2300 2-112" 2.875 2.635 3.530 2500 3" 3.500 3.260 4.340 1290 4" 4.500 4,260 5.620 1000 5" 5.563 5.295 7.780 1010 6" 6.625 6.357 9.300 1020 • 8"** 8.625 8.249 16.960 780 8"wall thickness is 0.188,not SCH10 or 0.148"wall thickness. COMPOSITION AND PROPERTIES Chemical and mechanical properties requirements are as prescribed by applicable ASTM standards edition January 2006. Chemical Requirements,Percent(Product) C Mn P S Other Specification Grade max max max max ASTM A53 A 0.250 0.950 0.05 0.045 - 1 Residual elements max:Cu-0.40,NI-0.40,Cr-0.40,Mo-0.15 and V-.08. These live elements combined shall not exceed 1%. Mechanical Properties-Tensile Requirements Stren -psi. Yield Tensile Specification Grade Min Max Min Max ASTM A53 A 30,000 - 48,000 - NOTE: Elongation requirements vary with nominal area of test specimen and specified minimum tensile strength of the steel grade. • 9615 S.Norwalk Blvd.,Santa Fe Springs,CA 90670 •(562)695-5555 "FAX:(562)692-1054 'www.statepipe.com State Pipe & Supply, Inc. THIS INFORMATION PROVIDED IS BASED ON ASTM GUIDELINES FOR WELDED PIPE SPECIFICATIONS AND ASTM REQUIREMENTS. ACTUAL PIPE AND MATERIAL TEST REPORTS PROVIDED WOULD MEET OR EXCEED THESE GUIDELINES. TEST REPORTS WOULD PROVIDE SPECIFIC AND ACTUAL DETAILS CONCERNING THE MECHANICAL AND CHEMICAL PROPERTIES OF THE ACTUAL PIPE,AS WELL AS ADDITIONAL TESTS RESULTS REQUIRED BY ASTM. SCHEDULE 40 Black and Galvanized Steel ERW Pipe Pipe Size Test Pressure Nominal O.D. I.D. Weight!Foot psi 1" 1.315 1.049 1.680 700 1-1l4" 1.660 1.380 2.270 1200 1-112" 1.900 1.610 2.720 1200 2" 2.375 2.067 3,660 2300 2-1/2" 2.875 2.469 5.800 2500 3" 3.500 3.068 7.580 2220 4" 4.500 4.026 10.800 1900 5" 5.563 5.047 14.630 1670 6" 6.625 6.065 18.990 1520 8'" 8.625 7.981 28.580 1340 COMPOSITION AND PROPERTIES Chemical and mechanical properties requirements are as prescribed by applicable ASTM standards edition January 2006. Chemical Requirements,Percent(Product) C Mn P S Other Specification Grade max max max Max ASTM A53 A 0.250 0.950 0 05 0.045 1 Residual elements max:Cu-0.40,Ni-D.40,Cr-0.40.Mo-0.15 and V-.OS. These live elements combined shall not exceed 1%. Mechanical Properties-Tensile Requirements Stren th-Psi. Yield Tensile Specification Grade Min Max Min Max ASTM A53 A 30,000 - 48,000 - NOTE; Elongation requirements vary with nominal area of test specimen and specified minimum tensile strength of the steel grade, • 9615 S,Norwalk Blvd„ Santa Fe Springs,CA 90670 •(562)695-5555 • FAX:(562)692-1054•www.statepipe.com ES-A-InBuildingRiser For Fire Protection Applications • Job Name Contractor Job Location Approval Engineer Contractor's P.O. No. Approval Representative • �� Series IBR In-Building Risers Customizable Sizes: 4" - 10" (100 -250mm) *� Building Floor • - Building perimeter wall TEST CAP W ING��pED, NO Da 6'x6'standard length (custom lengths from 3'—20'available) "Q.. ao QaV- =MN Flow z ooc, «^'k "end..... 1 Features Series IBR In-Building Risers are used to connect the main fire supply to the building overhead fire system.The fitting passes under the foundation without joints and ex- •Cost savings tends up through the floor. Provided with installation tabs,the unit has a CIPS(Cast •Corrosion resistant stainless steel Iron Pipe Size)coupler for easy connection to the underground supply(AWWA C900 construction, type 304 PVC and Ductile Iron Pipe)and industry standard grooved-end connection(AWWA •Ease of installation and light weight allows C606)on the building side for easy connection to the overhead fire sprinkler system. one person to position and handle the riser The IBR features Lead Free*construction to comply with Lead Free*installation requirements. •Minimal site preparation;joint restraint one- piece construction reduces time and labor; Ames In-Building Risers are precision engineered and manufactured to provide no missing parts, no leaks; easily identifiable exceptional reliability and reduce installation time&labor costs associated with field for approvals assembly. In accordance with NFPA 24,the UUFM approved In-Building Risers •Includes Test Cap and Coupler replace numerous fittings,elbows&spools and reduces the possibility of leaks or failure in comparison to traditional installation methods and materials. Factory tested •UUFM approved integrity ensures the highest quality installation.The use of stainless steel significantly •Sizes: available in 4"—10" (100-250mm) increases the reliability and life of the riser. with various lengths to meet local require- "'The wetted surface of this product contacted by consumable water contains less ments than 0.25%of lead by weight. •Designed to meet NFPA 24 •AWWA C900 Inlet/DIP • •AW WA C606 OutletMES �'`• Ames Fire&Waterworks product specifications in U.S.customary units and metric are approximate and are provided for reference only.For precise measure- A ments,please contact Ames Fire&Waterworks Technical Service.Ames Are&Waterworks reserves the right to change or modify product design,construction, FIRE&WATERWORKS specifications,or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames Fire&Waterworks products previously or subsequently sold. A WATTS Brand Specifications Standards In-Building Riser shall be installed as indicated on the plans. NFPA — Designed to allow the contractor to conform to NFPA Riser shall be composed of a single extended 90 degree fitting 24 of fabricated 304 stainless steel tubing, maximum working Where a riser is close to building foundations,underground • pressure 200psi(14 bar).The fitting shall have a grooved-end fittings of proper design and type shall be used to avoid pipe joints connection on the outlet(building)side and a CIPS coupler on being located under the foundations. the inlet(underground)side.The grooved end shall include a 1 coupler and cap to facilitate testing of the underground pip- End Connections ing.The In-Building Riser shall be an Ames Fire&Waterworks Series IBR. Horizontal End:Mates with Ductile Iron Pipe and AWWA C900 Pipe(PVC Pipe with Ductile Iron Pipe Equivalent OD's) Utilizes Gasket conforming to UL 157 with"Lock in" gasket configuration Approvals Fittings FM class 1920 UL HKOA(4"-10") in. mm in. mm 4 100 4.8 122 ® NSF 6 150 6.9 175 ).r7,,1 8 200 9.1 230 10 250 11.1 282 Dimensions —Weights _ H4_ A Vertical End: Meets AWWA C-606 dimensions for roll grooved pipe V Grooved End Meets AWWA C-207 class D for flanges (Flange Optional) 0 Ratings Meets AWWA C-900 pressure class 200,DR 14 Pipe B Testing Welds are 100%leak tested at the factory • CIPS Coupling Tie-Rod Bracket in. mm psi bar 4 100 1000 70 4 C 01 6 150 1000 70 8 200 800 56 10 250 800 56 SIZE(ON) WEIGHT A(OD) B C in. mm in. mm ft cm ft cm lbs. kg NOTICE 4 100 41/2 114 6 183 6 183 71 32 Inquire with governing authorities for local installation 6 150 6% 168 6 183 6 183 98 44 requirements 8 200 8% 219 6 183 6 183 129 59 10 250 103 273 6 183 6 183 202 92 ""Each B(vertical)and C(horizontal)leg is customizable from 3'to 20'with UUFM NOTICE approvals.Consult with your factory representative for details. The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer.You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product. A M E S FIRE&WATERWORKS, A WAITS Brand USA:Backflow Tel:(978)689-6066•Fax:(978)975-8350•ArnesFireWater.com USA:Control Valves Tel:(713)943-0688•Fax:(713)944-9445•AmesFireWater.com Canada: Tel:(905)332-4090•Fax:(905)332-7068•AmesFireWater.ca Latin America: Tel:(52)81-1001-8600•Fax:(52)81-8000-7091 •AmesFreWater.com ES-A-InBuildingRiser 1626 ©2016 Ames Fire&Waterworks • COOPLET® Weld Outlets & Adapter Nipples , ...,„ ., , ., ,,„ ,,,„ n, j,+L•-. ids 44 5tt fJ M� IY • tl t �i ss.F'"3f 5 x bI � e�€+gif e':a8 x kY Ixi :4 , 4 o " -- - -ts *y i.Y`y �� .�/ ImNC 44. 7Y " x + ' nx 5s~ix a °4#444. 1fiit/U-(.) ty .; tlI P Ai pY 1 - l ' j tl t b�YB q C"q 5 �b.tl p� 5 !Y `� i Div _ Y f���-.,�' I- „x �. •E,+' .P y� �a� e s- i rt. xsi'�„ i�� 4 tl t3lt... 4 9 $ ''� ...,,max u`iP z � �tl; �u € - } 4}y 0 / ,-,....:,.. , 4'n ^. _ ,, ,.„,, i , ,..,..„. ,.._, TM . • _ t.;AL1 PLU COOPLE ° Weld Outlets & Adapter Nip les Weld Outlet Specifications • ® Branded COOPLET®Weld Outlets are UL Listed and FM Approved at 300 psi • COOPLET®Weld Outlets (Threaded) conform to ASTM A-106, ASME B1.20.1 • COOPLET®Grooved Weld Outlets are made from Sch 40 Pipe, ASTM A-53 Grade A C CO US • COOPLET® Grooved Weld Outlets size-on-size are UL Listed Only LISTED • All Grooves are cut grooved per AWWA C606 41> • ProPakTM Packaging APPROVED COOPLET®Weld Outlets are UL Listed and FM Approved for use on Sch 10,Sch 40 and the following sprinkler pi,. Pipe Name Manufacturers Dyna-Thread',Central-Thread',XL",XL-II°,Dyna-Flow',Super 40', Allied Tube and Conduit Corp. Super-Flo',TL°,Central 7°,BLT Eddylite,Eddy F1ow,Eddy Thread 40' Bull Moose Tube Co. Cal-7° IDOD Systems Co. EZ-Flow Northwest Pipe Company WLS°,Mega F1ow,Mega-Thread',MLT',GU Wheatland Tube Company Steady F1ow,Steady Thread° Welded Tube Corp. Fire-Flo°,Ez-Thread' Youngstown Tube Co. Tex-Flows Tex-Tube International Fire Line Flows,Rapid Threads,Rapid-Thread Light' Western International Forest Products Inc. Adapter Nipple Specifications • Sch 40 COOPLET®Adapter Nipples conform to ASTM A-53, " ` '.= 7 f a:, Grade A, ASME B1.20.1, ASME B36.10, and AWWA C-606 E t • Sch 80 COOPLET®Adapter Nipples conform to ASTM A-106, goo ; te: F . ASME B1.20.1, ASME B36.10, and AWWA C-606 • All grooves are cut grooved per AWWA 606 i '' SCI ProPakTM System ~ _ COOPLET® Threaded Weld Outlets - 300# c ® uS -44;00- APPROVED Fig. 61FT1 - Threaded Weld Outlet LISTED Size Pipe Run Part Number A B Packing Weight in Size in in Inner Master lb °" 1/2 1 to 1-1/2 61 F 11004010 1.063 0.750 50 400 0,1 1/2 2 to 2-1/2 61FT1004020 1.063 0.750 50 400 0.1 1/2 3 to 8 61 FT 1004030 1.063 0.750 50 400 0,1 3/4 1 to 1-1/2 61FT1006010 1.125 0.875 50 300 0.2 • 3/4 2 to 2-1/2 61 FI 1006020 1.125 0.875 50 300 0.2 3/4 2-1/2 61FT1006024 1.125 0.875 50 300 0.2 3/4 3 to 8 61 FT1006030 1.125 0.875 50 300 0.2 1 1-1/4to1-1/2 61FT1010012 1.250 1.125 50 200 0.2 1 1-1/2 61FT1010014 1.250 1.125 50 200 0.2 1 2to2-1/2 61FT1010020 1.250 1.125 50 200 0.2 1 2-1/2 61 FT 1010024 1.250 1.125 50 200 0.2 _ 1 3 to 4 61 FT1010030 1.250 1.125 50 200 0.2 1 5 to 8 61FT1010060 1250 1.125 50 200 0.2 1-1/4 1-1/2 61FT1012014 1.375 1.500 70 140 0.3 '''' 010•11# 1-1/4 2 61FT1012020 1.375 1.500 70 140 0.3 1-1/4 2-1/2 61FT1012024 1.375 1.500 70 140 0.3 • A I 4 3 to 4 61FT1012030 1.375 1.500 70 140 0.3 1-1/4 5 to 8 61FT1012060 1.375 1.500 70 140 0.3 1-1/2 2 61FT1014020 1.625 1.625 50 100 0.5 1-1/2 2-1/2 61FT1014024 1.625 1.625 50 100 0.5 v ' 2 3 61 FT1014030 1.625 1.625 50 100 0.5 1-1/2 4 to 5 61FT1014040 1.625 1.625 50 100 0.5 (___). 1-1/2 6 to 8 61FT1014060 1.625 1.625 50 100 0.5 B 2 2-1/2 61FT1020024 1.750 2.000 25 50 0.8 2 3 61FT1020030 1.750 2.000 25 50 0.8 2 4 to 5 61FT1020040 1.750 2.000 25 50 0.8 2 6 to 8 61 FT1020060 1.750 2.000 25 50 0.8 2-1/2 3 61FT1024030 2.215 2.500 15 30 1.4 2-1/2 4 61FT1024040 2.215 2.500 15 30 1.4 2-1/2 6 61FT1024060 2.215 2.500 15 30 1.4 2-1/2 8 61FT1024080 2.215 2.500 15 30 1.4 3 4 61FT1030040 2.500 3.000 8 16 2.4 3 6 61FT1030060 2.500 3.000 8 16 2.3 3 8 61FT1030080 2.500 3.000 8 16 2.3 4 6 61 FT1040060 3.000 4.000 4 8 4,1 4 8 61FT1040080 3.000 4.000 4 8 4.0 '''') loe•... c ® uS Fig. 61 CC1 - Grooved Weld Outlet(size on size)* LISTED Size Pipe Run Part Number A B Packing Weight in Size in in Inner Master lb 1-1/4 1-1/4 610G1012012 3.00 1.38 40 80 0.5 1. 1-1/2 1-1/2 61CG1014014 3.00 1.61 25 50 0.6 la 2 2 610G1020020 3,00 2,00 16 32 0,8 I 2-1/2 2-1/2 61CG1024024 3.00 2.50 12 24 1.3 A I 3 3 61CG1030030 3,00 3,00 6 12 1.8 el Lk 4 4 61 CG 1040040 4.00 4.00 4 8 3.5 III I 6 6 61CG1060060 4.00 6.00 2 6,5 __ I 8 8 61 CG 1080080 4.00 8.00 2 11.6 94 V I `Size on Size Grooved Weld Outlets are UL Listed Only < ) B All Grooves are Cut Grooved 207 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com COOPLET® Grooved Weld Outlets- 300# ' ' t ; CCDUS APPROVED Fig. 61 CG1 - Grooved Weld Outlet LISTED Size Pipe Run Part Number A B Packing Weight , in Size in in Inner Master lb , .) t•s;a 1/4 1-1/2 610G1012014 3.00 1.38 40 80 0.5 114 2 61CG1012020 3.00 1.38 40 80 0.5 4 2-1/2 61CG1012024 3.00 1.38 40 80 0.5 1-1/4 3 61CG1012030 3.00 1.38 40 80 0.5 1-1/4 41o5 61CG1012040 3.00 1.38 40 80 0.5 1-1/4 6 to 8 61CG1012060 3.00 1.38 40 80 0.5 1-1/2 2 61CG1014020 3.00 1.61 25 50 0.6 1-1/2 2-1/2 61CG1014024 3.00 1.61 25 50 0.6 1-1/2 3 61CG1014030 3.00 1.61 25 50 0.6 g 1-1/2 4t05 61CG1014040 3.00 1.61 25 50 0.6 1-1/2 6 to 8 61CG1014060 3.00 1.61 25 50 0.6 1 2 2-1/2 61CG1020024 3.00 2.00 16 32 0.8 2 3 610G1020030 3.00 2.00 16 32 0.8 1 A 1 1 2 4 to 5 61 CG 1020040 3.00 2.00 16 32 0.8 2 6 61 CG 1020060 3.00 2.00 16 32 0.8 2 8 61 CG 1020080 3.00 2.00 16 32 0.8 C: 1 2-1/2 3 61CG1024030 3.00 2.50 12 24 1.3 0 1 2-1/2 4 to 5 61 CG 1024040 3.00 2.50 12 24 1.3 Q 2-1/2 6 61CG1024060 3.00 2.50 12 24 1.3 p_ q I Li -- 2-1/2 8 61CG1024080 3.00 2.50 12 24 1.3 L_ I r 3 4 61 CG 1030040 3.00 3.00 6 12 1.8 3 6 61CG1030060 3.00 3.00 6 12 1.8 T 3 8 61 CG 1030080 3.00 3.00 6 12 1.7 B 4 6 61 CG 1040060 4.00 4.00 4 8 3.5 4 8 61 CG 1040080 4.00 4.00 4 8 3.4 All Grooves are Cut Grooved 6 8 61 CG 1060080 4.00 6.00 - 2 6.5 h Fig. 61GB4 -Schedule 40 Grooved x Bevel Adapter Nipple Size A B Weight in Part Number in in Master lb 1 x 3 61GB4010030 3.00 1.32 150 0.3 1 x4 61GB4010040 4.00 1.32 100 0.5 1-1/4x4 61GB4012040 4.00 1.66 50 0.6 1-1/2x4 61GB4014040 4.00 1.90 50 0.7 2 x 4 61 G B4020040 4.00 2.38 25 1.1 2-1/2 x 4 61 GB4024040 4.00 2.88 27 1.6 3 x 4 61GB4030040 4.00 3.50 18 2.4 4 x 6 61GB4040060 6.00 4.50 8 5.1 5 x 6 61GB4050060 6.00 5.56 2 6.6 6 x 6 61GB4060060 6.00 6.63 2 8.6 8 x 6 61GB4080060 6.00 8.63 2 13.2 A 1 Bevel 411 �'37-1/2° ( ) B SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323) 890-4456 • www.smithcooper.com 208 t* 't:4 COOPLET®Adapter Nipples • Fig. 61 TG4 -Schedule 40 Threaded x Grooved Adapter Nipple Size A B Weight in Part Number in in TPI Master lb 1 x4 61TG4010040 4.00 1.32 11.5 100 0.5 . .- r---- i 1-1/4 x 4 61TG4012040 4.00 1.66 11.5 50 0.6 1-1/2 x 4 61TG4014040 4.00 1.90 11.5 50 0.7 1-1/2 x 12 61TG4014120 12.00 1.90 11.5 15 2.6 € `s 2 x 3 61TG4020030 3.00 2.38 11.5 50 0.7 2 x 4 61TG4020040 4.00 2.38 11.5 25 1.0 il '• 2 x 6 61TG4020060 6.00 2.38 11.5 25 1.7 ,'_,, : 2 x 8 61TG4020080 8.00 2.38 11.5 18 2.3 ri 2 x 10 61TG4020100 10,00 2.38 11.5 14 2.9 s 2 x 12 61TG4020120 12.00 2.38 11.5 14 3.5 2-1/2 x 4 61TG4024040 4.00 2.88 8.0 27 1.6 2-1l2 x 12 61TG4024120 1262 2.88 8.0 9 5.5 3 x 2-5/8 61134030025 262 3.50 8 0 24 1.3 3 x 3 61TG4030030 3.00 3.50 8.0 24 1.5 3 x 4 61 TG4030040 4.00 3.50 8.0 18 2.1 -•ar' 3 x 6 61 TG4030060 6.00 3.50 8.0 12 3.4 3 x 8 61TG4030080 8.00 3.50 8.0 6 4.7 :It', 3 x 10 61 TG4030100 10.00 3.50 8.0 6 5.9 4 3 x 12 61TG4030120 12.00 3.50 8.0 6 7.2 h 4 x 3 61 TG4040030 3.00 4.50 8.0 12 1.6 4 x 4 61TG4040040 4.00 4.50 8.0 12 2.6 °' 4 x 6 61TG4040060 6.00 4.50 8.0 8 4.9 1 4 x 8 61TG4040080 8.00 4.50 8,0 5 6.7 4 x 10 61TG4040100 10.00 4.50 8.0 4 8.5 1Flet B 4 x 12 61TG4040120 12.00 4.50 8.0 4 10.3 '' ( 5 x 6 61TG4050060 6.00 5.56 8.0 2 6.6 \ I 5 x 12 61TG4050120 12.00 5,56 8.0 1 13.9 \ 6 x 6 61TG4060060 6.00 6.63 8.0 2 8.6 6 x 12 61 TG4060120 12 00 6.63 8.0 18.1 8 x 6 611G4080060 6.00 8.63 8.0 13.2 \ \ 8 x 12 61TG4080120 12.00 8.63 8.0 1 27.5 \ \ A \ \ Fig. 61TG8 -Schedule 80 Threaded x Grooved Adapter Nipple \ Size A B Weight \ \ in Part Number i� in TPI Master lb \ 2 x 3 61TG8020030 3.00 2.38 11.5 50 1.1 2 x 4 61TG8020040 4.00 2.38 11.5 25 1.5 I ''./ 2 x 6 61TG8020060 6.00 2.38 11.5 25 2,3 I 2 x 8 61TG8020080 8.00 2.38 11.5 18 3.2 I 2 x 10 61TG8020100 10.00 2.38 11.5 12 4.0 2 x 12 61TG8020120 12.00 2.38 11.5 12 4.9 3 x 2-5/8 61TG8030025 2.62 3.50 8.0 24 1.9 3 x 3 61TG8030030 3.00 3.50 8.0 24 2.2 3 x 4 61TG8030040 4.00 350 8.0 18 3.0 3 x 6 61TG8030060 6.00 3.50 8.0 12 4.7 3 x 8 61TG8030080 8.00 3.50 8.0 8 6.5 3 x 10 61TG8030100 10.00 3.50 8.0 6 8.2 3 x 12 61TG8030120 12.00 3,50 8.0 6 9.9 4 x 3 61TG8040030 3.00 4.50 8.0 12 3.2 4 x 4 61TG8040040 4.00 4.50 8.0 12 4.5 4 x 6 61 TG8040060 6.00 4.50 8.0 8 7.0 4 x 8 61 T G8040080 8.00 4.50 8.0 5 9.5 4x 10 61TG8040100 10.00 4.50 8.0 4 12.0 4 x 12 61 TG8040120 12.00 4.50 8.0 4 14.5 • 209 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323) 890-4456 • www.smithcooper.com COOPLET® Adapter Nipplest Fig. 61GG4 -Schedule 40 Grooved x Grooved Adapter Nipple • +rrl rt , Size A B Weight in Part Number in in Master lb 2 x 3 61GG4020030 3.00 2.38 50 0.8 .. 2 x 4 61 GG4020040 4.00 2.38 50 1.1 2 x 6 61GG4020060 6.00 2.38 25 1.7 2 x 8 61GG4020080 8.00 2.38 18 2.3 f 2x10 61GG4020100 10.00 2.38 14 2.9 2x 12 61GG4020120 12.00 2.38 14 3.5 3 x 2-5/8 61 GG4030025 2.62 3.50 24 1.5 3 x 3 61GG4030030 3.00 3.50 24 1.7 3 x 4 61 GG4030040 4.00 3.50 18 2.4 3 x 6 61GG4030060 6.00 3.50 12 3.6 3 x 8 61GG4030080 8.00 3.50 8 4.9 , ":�' 3 x 10 61GG4030100 10.00 3.50 6 6.2 3 x 12 61664030120 12.00 3.50 6 7.4 4 x 3 61GG4040030 3.00 4.50 12 2.4 4 x 4 61GG4040040 4.00 4.50 12 3.3 4 x 6 61GG4040060 6.00 4.50 8 5.1 4 x 8 61GG4040080 8.00 4.50 5 6.9 4 x 10 61GG4040100 10.00 4.50 4 8.7 0 4 x 12 61GG4040120 12.00 4.50 4 10.3 0 Fig. 61GG8 -Schedule 80 Grooved x Grooved Adapter Nipple L° \ Size Part Number A B Master Weight in in in lb ; 2 x 3 61GG8020030 3.00 2.38 50 1.1 A \ 2 x 4 61GG8020040 4.00 2.38 25 1.5 2 x 6 61GG8020060 6.00 2.38 25 2.4 2 x 8 61GG8020080 8.00 2.38 18 3.2 2x10 61GG8020100 10.00 2.38 12 4.1 2x12 61GG8020120 12.00 2.38 12 4.9 3 x 2-5/8 61GG8030025 2.62 3.50 24 2.1 3 x 3 61GG8030030 3.00 3,50 24 2.4 ( B ) 3 x 4 61GG8030040 4.00 3.50 18 3.3 3 x 6 61GG8030060 6.00 3.50 12 5.0 3 x 8 61GG8030080 8.00 3.50 8 6.7 3 x 10 61GG8030100 10.00 3.50 6 8.4 3 x 12 61GG8030120 12.00 3.50 6 10.1 4 x 3 61GG8040030 3.00 4.50 12 3.4 4 x 4 61GG8040040 4.00 4.50 12 4.7 4 x 6 61GG8040060 6.00 4.50 8 7.2 4 x 8 61GG8040080 8.00 4.50 5 9.7 4 x 10 61GG8040100 10.00 4.50 4 12.2 4 x 12 61GG8040120 12.00 4.50 4 14.7 • SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323) 890-4456 • www.sminccoopcccom 210 ICI I Fire & Building • Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 Grinnell Grooved Fire Protection Products Fire Protection Submittal Sheet • Listing and Approval Information [L B VdS • I®® Page 1 of 8 MARCH 2011 TFP1800 Page 2 of 8 TFP1800 Rated Pressure Nominal Size Nominal Size (psi-UL,ULC,FM;Bar LPCB and VdS) Figure Inches mm Pipe Schedule pp DL LC FM VdS 0113; 1 V4,1 Vz,2 42.4,48.3,60.3 Sch 5,ID,WST 175 175 175 - - • 1'/4,1 V2,2,21/2 42.4,48.3,60.3,73.0 Sch 10,Sch 40 300 300 300 - - 3,4,5,6,8 88.9,114.3,141.3,168.3,219.1 Sch 10,Sch 40 300 300 300 - - 10,12 273.0,323.9 Sch 10,Sch 40 250 250 250 - - 1 V4,1'/2,2,212,3 42.4,48.3,60.3,73.0,88.9 MF 300 300 300 - - 4 114.3 MF - - 300 - - 1'/4,1'/z,2,2'/z,3,4 42.4,48.3,60.3,73.0,88.9,114.3 DF 300 300 300 - - 114,11/2,2,21/2,3,4 42.4,48.3,60.3,73.0,88.9,114.3 FLF 300 300 - - - 11/2,2,21/2,3,4 48.3,60.3,73.0,88.9,114.3 FF 300 300 300 - - 1,11/4,1 V2,2 33.7,42.4,48.3,60.3 MLT,EZT 300 300 300 - - 3 88.9 EZ 300 300 300 4 114.3 EZ 250 250 300 � � 6 168.3 EZ 250 250 175 - - 1'/4,1'/2,2 42.4,48.3,60.3 BLT,DT,TL,Gal 7,Gal Flo 300 300 300 - - Figure 705 11/4,11/2,2 42.4,48.3,60.3 GL,MLT,MT,SL,WLS 300 300 - - - 1'/4,1 V2,2 42.4,48.3,60.3 UE - - 175 - - 76.1,165.1 8S1387 300 300 300 - - 42.4,48.3,60.3,76.1,88.9,114.3 BS1387,ISO 4200 - - - 16 20 139.7 BS1387,ISO 4200 - - - 16 - 165.1 BS1387,ISO 4200 - - - - 20 168.3,219.1 ISO 4200 - - - 16 20 108.0,133.0,159.0 ISO 4200 300 - 300 - - 216.3 JIS G3452 300 - 300 - - 11/2,2,21/2 48.3,60.3,73.0 Sch 5, UE,WST 175 175 175 - - 11/2,2,21/2,3,4,5 48.3,60.3,73.0,88.9,114.3,141.3 Sch 10 450 450 450 - - 6,8,10,12 168.3,219.1,273.0,323.9 Sch 10 450 450 450 - - 11/2,2,21/2,3,4,5 48.3,60.3,73.0,88.9,114.3,141.3 Sch 40 500 500 500 - - 6,8,10,12 168.3,219.1,273.0,323.9 Sch 40 500 500 500 - - • 1'/z,2,2'/z,3,4 48.3,60.3,73.0,88.9,114.3 MF,DF,FF,SF,STF 300 300 300 - - 2 60.3 EZT 300 - - - - 3 88.9 EZ 300 300 300 - - _ 4 114.3 EZ 250 250 300 - - 6 168.3 EZ 250 250 175 - - ; 0 1 V2,2,21/2,3 48.3,60.3,73.0,88.9 XL 300 300 300 11 1 h,2 48.3,60.3 GL,MT,MLT,TL 300 300 300 11/2,2 48.3,60.3 Gal 7,Gal Flo 300 300 300 - - Figure 707 172 2 48.3,60.3 BLT,DT - - 300 - - 14,16 355.6,406.4 Sch 30 300 - - - - 18,20 457.2,508.0 Sch 30 200 - - - - 24 610.0 Sch 20 250 - - - - 76.1,165.1 BS1387,ISO 4200 300 - 300 - 20 48.3,60.3,88.9,114.3,168.3 BS1387,ISO 4200 - - - - 20 219.1,273.0,323.9 ISO 4200 - - - 16 20 2 60.3 Sch 5,ID,UE,WST 175 175 175 - - 2,2'/2,3,4,5 60.3,73.0,88.9,114.3,141.3 Sch 10,Sch 40 250 250 250 - - 6,8 168.3,219.1 Sch 10,Sch 40 250 250 250 - - 10,12 273.0,323.9 Sch 40 250 250 250 - - •<<''' 4. 2 60.3 BLT,DT,EZT,FF,GL,LS 250 250 250 - - 2 60.3 MT,MLT,TL,WLS,XL 250 250 250 - - • • 2 60.3 Gal 7,Gal Fla 250 250 250 - - . 2 60.3 MF,FF - - 250 - - !2 ' ,V.—' 2,21/2,3,4 60.3,73.0,88.9,114.3 OF,FF,MF,SF 250 250 250 - - 3,4 88.9,114.3 EZ 250 250 250 - - Figure 71 6 168.3 EZ 250 250 175 - - 2,3,4 60.3,88.9,114.3 STF 250 250 250 - - 21/2,3 73.0,88.9 XL 250 250 250 - - • 60.3,76.1,88.9,114.3,168.3 BS1387,ISO 4200 250 - 250 16 20 139.7 BS1387,ISO 4200 250 - 250 16 - Figure 71 PN16 165.1 BS1387,ISO 4200 250 - 250 - 20 219.1,273.0 ISO 4200 250 - 250 - 20 323.9 ISO 4200 250 - 250 - 16 TFP1800 Page 3 of 8 Rated Pressure Figure Nominal Size Nominal Size (psi-UL,ULC,FM;Bar LPCB and VdS) 9 Inches mm Pipe Schedule ® Lc <> [vas] (u'cs) • 1'/4,1'/2,2 42.4,48.3,60.3 Sch 5,ID,UE,WST Sch 10,Sch 40 175 175 175 1V4 42.4 300 300 300 1'/z,2,2'/2,3,4 48.3,60.3,73.0,88.9,114.3 Sch 10,Sch 40 500 500 500 - - 5,6 141.3,168.3 Sch 10 300 300 300 - - 8 219.1 Sch 10 400 400 400 - - 5 141.3 Sch 40 300 300 300 - - 6 168.3 Sch 40 400 400 400 - - 8 219.1 Sch 40 450 450 450 - - 10,12 273.0,323.9 Sch 10,Sch 40 250 250 250 - - IA,1'/2,2,2'/2,3 42.4,48.3,60.3,73.0,88.9 MF 300 300 300 - - 4 114.3 EZ,MF 250 250 300 - - 3 88.9 EZ 300 300 300 - - 6 168.3 EZ 250 250 300 - - 1'/2,2,2'/z,3,4 48.3,60.3,73.0,88.9,114.3 DF,STF 300 300 300 - - 1 .;01'/4,Ph,2,2'/z,3 42.4,48.3,60.3,73.0,88.9 FLF 300 300 4 114.3 FLF 250 250 - - - Figure 772 11/2,2,2'/z,3 48.3,60.3,73.0,88.9, FF 300 300 300 - - Patented 4 114.3 FF 250 250 300 - - Ph,1'h,2 42.4,48.3,60.3 EZT,MT,MLT,WLS 300 300 300 - - 1'/4,1'/2,2 42.4,48.3,60.3 GL,Gal 7,Gal Fla 300 300 300 - - P/z,2 48.3,60.3 BLT,DT 300 300 300 - - 1'/2,2 48.3,60.3 TL,XL 300 300 - - - 76.1,165.1 BS1387 300 300 300 - - 42.4,48.3,60.3,76.1,88.9,114.3 BS1387,ISO 4200 - - - 16 20 1 139.7 BS1387,1S04200 - - - 16 - 165.1 BS1387,ISO4200 - - - - 20 168.3,219.1,273.0,323.9 ISO 4200 - - - 16 20 2x11/2,2'/2x2,3x2 60.3 x 48.3,73.0 x 60.3,88.9 x 60.3 Sch 5 175 175 175 - - • 3x21/2,4x2,4x21/2 88.9 x 73.0,114.3 x 60.3,114.3 x 73.0 Sets 175 175 175 2x1'1z,2'/zx2,3x2 60.3x48.3,73.0x60.3,88.9x60.3 Sch10,Sch 40 350 350 350 3x21/2,4x2,4x21/2 88.9 x 73.0,114.3 x 60.3,114.3 x 73.0 Sch 10,Sch 40 350 350 350 - - 4x3,5x4 114.3x88.9,141.3,114.3 Sch10,Sch40 350 350 300 - - 6x4,6x5 168.3x114.3x1638.3x141.3 Sch 10,Sch 40 350 350 300 - - 8 x 6 219.1 x 168.3 Sch 40 350 350 300 - - 2x1'/z,2Vzx2,3x2 60.3x48.3,73.0x60.3,88.9x60.3 DF,EZT,FF,GL,MF 300 300 300 - - 2x1'/z,2'/2x2,3x2 60.3 x 48.3,73.0x 60.3,88.9 x 60.3 MT,MLT,SF,STF,TL 300 300 300 - - 4x2 114.3x60.3 OF,EZT,FF,GL,MF 300 300 300 - - 4x2 114.3x60.3 MT,MLT,SF,STF,TL 300 300 300 - - , 3x21/2,4x2'/z,4x3 88.9 x 73.0,114.3 x 73.0,114.3 x 88.9 DF,MF,SF 300 300 300 - - I I 4x2'/z,4x3 114.3x73.0,114.3x88.9 FF,STF 300 300 300 - - 5x4,6x4 141.3x114.3,168.3x114.3 IF,FF,SF,STF 300 300 300 - - Figure 716 3x2,3x21/2 88.9x60.3,88.9x73.0 EZ 300 300 300 - - 2x1'/z 60.3x48.3 Gal 7,Gal Flo 300 300 300 - - 60.3 x 48.3,73.0 x 60.3,88.9 x 60.3 BS1387,150 4200 300 - 300 16 20 88.9x 76.1,114.3 x 60.3,114.3 x 76.1 B51387,ISO 4200 300 - 300 16 20 114.3x88.9 1351387,1S04200 300 - 300 16 20 168.3 x 114.3,219.1 x 168.3 ISO 4200 300 - 300 16 20 139.7 x 114.3 1351387,1SO 4200 300 - 300 16 - 165.1 x 114.3 B51387,ISO 4200 300 - 300 - 20 11/4,11/2,2 x'/2,'14,1 42.4,48.3,60.3x 21.3,26.7,33.7 Sch 5,Sch 10,Sch 40 175 175 175 - - 1'/4,1'/2,2 x'/2,'/4,1 42.4,48.3,60.3 x 21.3,26.7,33.7 BLT,OF,DT,GL,LS,MF 175 175 175 - - 1'/4,1'/2,2 x'/2,'/4,1 42.4,48.3,60.3 x 21.3,26.7,33.7 MT,MLT,TL,WLS,XL 175 175 175 - - 1'/4,1'/2,2 x'/2,'/4,1 42.4,48.3,60.3 x 21.3,26.7,33.7 Gal 7,Gal Fla 175 175 175 1'/4,11/2 x 1/2,'/4,1 42.4,48.3 x 21.3,26.7,33.7 EZT 175 175 175 - - 1'/z x 1/2,3/4,1 48.3 x 21.3,26.7,33.7 FF 175 175 175 - - * 21/2 x'/2,'/4,1 73.0 x 21.3,26.7,33.7 Sch 10,Sch 40 175 175 175 - - • Figure 40-5• 2'/z x1/2,'/4,1 73.O x 21.3,26.7,33.7 OF,MF,STF,XL 175 175 175 1'!2,2 x1h,'/4,1 48.3,60.3 x 21.3,26.7,33.7 STF 175 175 175 • Figure 40-5 Straps are UL and ULC Listed and FM Approved with NPT and ISO threaded outlets as specified in the chart. Page 4 of 8 TFP1800 Rated Pressure Nominal Size Nominal Size Pipe (psi-UL,ULC and FM;bar LPCB and VdS) Figure Inches mm Schedule BL LC VdS MI3] 2 x V2,3/4,1,11 4,1'/2 60.3 x 21.3,26.7,33.7,42.4,48.3 Sch 5 175 175 175 - - • 2 x'/2,3/4,1,1'/4,1'I 60.3 x 21.3,26.7,33.7,42.4,48.3 Sch 10,Sch 40 300 300 300 - - 2'h x'/2,3/4,1,11/4,11/2,2 73.0 x 21.3,26.7,33.7,42.4,48.3,60.3 Sch 10,Sch 40 300 300 300 - - 3,4 x V2,3/4,1 88.9,114.3 x 21.3,26.7,33.7 Sch 10,Sch 40 300 300 300 - - 4 x 2'h,4 x 3 114.3 x 73.0,4 x 88.9 Sch 10,Sch 40 300 300 300 - - 5 x 2,5 x 2'/2 141.3 x 60.3,141.3 x 73.0 Sch 10,Sch 40 300 300 300 - - 6 x t'h,2,2V2,3,4 168.3 x 48.3,60.3,73.0,88.9,114.3 Sch 10,Sch 40 300 300 300 - - 2 x'/2,3h,1,1 V4,1 V2 60.3 x 21.3,26.7,33.7,42.4,48.3 BLT,DT,EZT,FF GL,MF 300 300 300 - - 2 x'/2,3/4,1,1'14,1'h 60.3 x 21.3,26.7,33.7,42.4,48.3 MT,MLT,STF,TL,WLS 300 300 300 - - 2 a'/2,3/4,1,1'/4,1'/2 60.3 x 21.3,26.7,33.7,42.4,48.3 Gal 7,Gal Flo 300 300 300 - - 2 x'/2,3/4,1 60.3 x 21.3,26.7,33.7 DF 300 300 300 - - rit 2V2,3,4 X'h,3/4,1 73.0,88.9,114.3 x 21.3,26.7,33.7 DF,FF,MF,STF 300 300 300 - - '1E 2 x 1'/4,1'/2 60.3 x 42.4,48.3 DF 300 300 300 - - 3,4 x 2 88.9,114.3 x 60.3 DF,FF,MF,STF 300 300 300 - - x 4 x 2'h 114.3 x 73.0 OF,FF,MF,STF 300 300 300 - - 4 x 3 114.3 x 88.9 FF,MF,STF 300 300 300 - - _ ' 76.1 x 21.3,26.7,33.7 BS1387,ISO 4200 300 - 300 16 20 139.7 x 48.3,88.9 BS1387,ISO 4200 300 - 300 16 20 Figure 730 165.1 x 42.4 BS1387,ISO 4200 300 - 300 16 20 Threaded*$ 60.3 x 21.3,26.7,33.7,42.4,48.3 BS1387,ISO 4200 - - - 16 20 76.1 x 42.4,48.3,60.3 BS1387,IS0 4200 - - - 16 20 88.9 x 21.3,26.7,33.7,42.4,48.3,60.3 BS1387,ISO 4200 - - - - 16 20 114.3 x 21.3,26.7,33.7,42.4 BS1387,ISO 4200 - - - 16 20 114.3 x 48.3,76.1,88.9 BS1387,ISO 4200 - - - 16 20 165.1 x 48.3,60.3,76.1,88.9,114.3 BS1387,ISO 4200 - - - - 20 139.7 x 60.3,76.1 BS1387,ISO 4200 - - - 16 - 168.3 x 48.3,60.3,73.0 ISO 4200 - - - 16 20 168.3,219.1 x 76.1,88.9,114.3 ISO 4200 - - - 16 20 2 x 1'h 60.3 x 48.3 Sch 5 175 175 175 - - 2,2'h,3,4,5,6 x 1'/2 60.3,73.0,88.9,114.3,141.3,168.3 x 48.3 Sch 10,Sch 40 300 300 300 - - 3,4,5 x 2,2V2 88.9,114.3,141.3 x 60.3,73.0 Sch 10,Sch 40 300 300 300 - - • 4 x 3,5 x 3 114.3 x 88.9,141.3 x 88.9 Sch 10,Sch 40 300 300 300 - - 6 x 2'/2,3,4 168.3 x 48.3,73.0,88.9,114.3 Sch 10,Sch 40 250 250 250 - - 8 x 2'/2,3,4 219.1 x 73.0,88.9,114.3 Sch 10,Sch 40 300 300 300 - - 2,2V2,3,4 x 1'h 60.3,73.0,88.9,114.3 x 48.3 DF 300 300 300 - - 3,4 x 2 88.9,114.3 x 60.3 DF 300 300 300 - - 4= 2 x V12 60.3 x 48.3 BLT,TL 300 300 300 - - 3 x 1'/2 88.9 x 48.3 EZ 300 300 300 - '°r 139.7 x 48.3,88.9 BS1387,150 4200 300 - 300 16 20 165.1 x 42.4,48.3,60.3,76.1 BS1387,ISO 4200 300 - 300 16 20 ti. .,_ 1" 60.3 x 42.4,48.3 BS1387,ISO 4200 - - - 16 20 76.1 x 42.4,48.3,60.3 BS1387,ISO 4200 - - - 16 20 Figure 730 88.9 x 42.4,48.3,60.3 BS1387,ISO 4200 - - - 16 20 Grooved**$ 114.3 x 42.4,48.3,60.3,76.1,88.9 BS1387,ISO 4200 - - - 16 20 165.1 x 48.3,60.3,76.1,88.9,114.3 BS1387,ISO 4200 - - - - 20 139.7 x 60.3,76.1 BS1387,ISO 4200 - - - 16 - 168.3 x 48.3,60.3,73.0 ISO 4200 - - - 16 20 168.3,219.1 x 76.1,88.9,114.3 ISO 4200 - - - 16 * Figure 730 Threaded Mechanical Outlets are UL and ULC Listed and FM Approved in both the Tee and Cross configuration with NPT and ISO threaded outlets as specified in the chart. **Figure 730 Grooved Mechanical Outlets are UL and ULC Listed and FM Approved in both the Tee and Cross configuration. t Figure 730 Threaded and Grooved Mechanical Outlets are VdS Approved in the Tee configuration only. Grinnell®products are UL and ULC Listed and FM, LPCB and VdS Approved, as specified in the charts, for the pressure ratings shown for use in Fire Protection Systems (automatic sprinkler, open sprinkler and standpipe) and connections to such systems. The charts were developed from the latest Listings and Approval data available at the time of publication. Listings are subject to changes and additions by the approval bodies. For Dry Pipe systems or Freezer Systems, use Tri-Seal Gaskets and petroleum free silicone lubricant. Follow installation instructions provided in the Installation Handbook IH-1000. • TFP1800 Page 5 of 8 Nominal Size Nominal Size Rated Pressure Figure Inches mm Pipe Schedule (psi-UL,ULC,FM;Bar LPCB and VdS) 0 LO O (vas) WO • 1-1/4,1-1/2,2 42.4,48.3,60.3 FLF,MF,XL,GL,10,40,CT,DF,TL, 300 300 300 WLS,MT,MLT 2-1/2,3,4 73.0,88.9,114.3 FLF,MF,OF 300 300 300 2-1/2,3 73.0,88.9 FF,XL 300 300 300 1-1/4,1-1/2,2, 42.4,48.3,60.3,73.0,88.9,114.3, 10 300 300 300 2-1/2,3,4,6,8 168.3,219.1 1-1/4,1-1/2,2, 42.4,48.3,60.3,73.0,88.9,114.3, 40 300 300 300 2-1/2,3,4,6 168.3 1,1-1/4,1-1/2,2 33.7,42.4,48.3,60.3 5 175 175 175 3,4,6 88.9,114.3,168.3 EZF 300 300 300 1 1/4 42.4 EZT 300 300 300 1-1/2,2 48.3,60.3 EZT,FF 300 300 300 y 1-1/2,2,2-1/2,3,4 48.3,60.3,73.0,88.9,114.3 STF 300 300 300 v 4 114.3 STF 250 250 250 8 219.1 0.188 in.wall 300 300 300 10,40,XL,TL,DF,BLT,DL,DT,MT, I 1 33.7 WLS,WST,GL,MLT,EZT,ET,EL,5, 300 300 300 Figure 577 BS1387M,ISO 4200 5 141.3 10 300 300 300 5 141.3 40 300 300 300 76.1 mm,165mm BS1387M,ISO 4200 300 300 139.7mm ISO 4200 300 300 1,1-1/4,1-1/2,2,3,4 33.7,42.4,48.3,60.3,88.9,114.3 BS1387M,ISO 4200 20 bar 76.1,165.1 BS1387M,ISO 4200 20 bar 6,8 168.3,219.1 ISO 4200 20 bar • 1,1-1/4,1-1/2,2,3, 33.7,42.4,48.3,60.3,88.9,114.3, ISO 4200 16 bar 4,6,8 168.3,219.1 76.1,139.7 ISO 4200 16 bar Pipe Schedule Key MF-Mega Flow Listed/Approved steel sprinkler pipe manufactured by Wheatland Tube Company. STF-Steady Flow Listed/Approved steel sprinkler pipe manu- MLT-Mega Light Listed/Approved steel sprinkler pipe manu- factured by AMS Tube Corp. factured by Wheatland Tube Company. BLT-Black Light Wall Threadable Listed/Approved steel sprin- MT-Mega Thread Listed/Approved steel sprinkler pipe manu- kler pipe manufactured by Allied Tube and Conduit. factured by Wheatland Tube Company. DF-Dyna-Flow Listed/Approved steel sprinkler pipe manufac- SL-Listed/Approved steel sprinkler pipe manufactured by tured by Allied Tube and Conduit. Wheatland Tube Company. DT-Dyna-Thread Listed/Approved steel sprinkler pipe manu- WLS-WLS Listed/Approved steel sprinkler pipe manufactured factured by Allied Tube and Conduit. by Wheatland Tube Company. SF-Super-Flow Listed/Approved steel sprinkler pipe manu- WST-WST Listed/Approved steel sprinkler pipe manufactured factured by Allied Tube and Conduit. by Wheatland Tube Company. XL-Extra Light Weight Listed/Approved steel sprinkler pipe GL-GL Listed/Approved steel sprinkler pipe manufactured by manufactured by Allied Tube and Conduit. Wheatland Tube Company. UE-Ultra-Eddy Listed/Approved steel sprinkler pipe manufac- EZT-EZ Thread Listed/Approved steel sprinkler pipe manu- tured by Bull Moose Tube Company. factured by Youngstown Tube Company. TL-TL Listed/Approved steel sprinkler pipe manufactured by FF- Fire-Flo Listed/Approved steel sprinkler pipe manufac- Central Grooved Piping Products. tured by Youngstown Tube Company. LS-Listed/Approved steel sprinkler pipe manufactured by 5 -Schedule 5 steel sprinkler pipe Century Tube Corporation. 10-Schedule 10 steel sprinkler pipe ID-IDOD Listed/Approved steel sprinkler pipe manufactured 20-Schedule 20 steel sprinkler pipe by IDOD Systems. 30-Schedule 30 steel sprinkler pipe GAL-FLO-Listed/Approved steel sprinkler pipe manufactured 40-Schedule 40 steel sprinkler pipe by IDOD Systems. BS1387m-British Standard Medium Listed/Approved steel GAL-7-Listed/Approved steel sprinkler pipe manufactured by sprinkler tube. IDOD Systems. ISO4200-ISO Standard Listed/Approved steel sprinkler tube. EZ-EZ-Flow Listed/Approved steel sprinkler pipe manufac- JIS G3452-Japanese International Standard tured by Northwest Pipe and Casting Company. FLF-Fire Line Flow Listed/Approved steel sprinkler pipe man- Note: Cut and roll grooved references are for pipe runs and ufactured by Western International Forest Products. also grooved outlets. Page 6 of 8 TFP18OO Rated Pressure Figure Nominal Size Nominal Size (psi-UL,ULC,FM;Bar PCB and VdS) Inches mm U� �� FM wdS]ILPCBI s 1'/2 x V2,'/4,1 42.4 x 21.3,26.7,33.7 300 300 300 - - FigureADACAP® , 4111) ADACAP®` 2 x V2,3/4,1 48.3 x 21.3,26.7,33.7 300 300 300 2'/z x'/s,3/4,1 60.3 x 21.3,26.7,33.7 300 300 300 - - ', 1 33.7 500 500 500 - - 1'/4,1'/z,2,3,4 42.4,48.3,60.3,88.9,114.3 500 500 500 16 20 6,8 168.3,219.1 500 500 500 16 20 10 273.0 450 450 450 16 20 I Figure 12 323.9 450 450 400 16 20 201 21/2,5 73.0,141.3 500 500 500 - - 76.1 500 - 500 16 20 165.1 500 - 500 - 20 Figure 201 139.7 500 - 500 16 - 45°Elbow 1 108.0,133.0,159.0,216.3 300 - 300 - - 1i 1 33.7 500 500 500 - - IT 1'74,1'/z,2,3,4 42.4,48.3,60.3,88.9,114.3 500 500 500 16 20 6,8 168.3,219.1 500 500 500 16 20 10 273.0 450 450 450 16 20 Figure 12 323.9 450 450 400 16 20 210 2'/z,5 73.0,141.3 500 500 500 - - Figure 210 ' y 76.1 500 500 16 20 90°Elbow „«, a ,':°':' 165.1 500 - 500 - 20 ;•" 139.7 500 - 500 16 - x 108.0,133.0,159.0,216.3 300 - 300 - - 1 33.7 500 500 500 - - 1'/4,1'/2,2,3,4 42.4,48.3,60.3,88.9,114.3 500 500 500 16 20 6,8 168.3,219.1 500 500 500 16 20 • 10 273.0 450 450 450 16 20 Figure 12 323.9 450 450 400 16 20 219 21/2,5 73.0,141.3 500 500 500 - - p4 *#`; 440 76.1 500 - 500 16 20 165.1 500 - 500 - 20 Figure 219 - 139.7 500 - 500 16 - Tee -- 108.0,133.0,159.0,216.3 300 - 300 - - 1 1/4,11/2,2,3,4 42.4,48.3,60.3,88.9,114.3 500 500 500 16 20 6,8 168.3,219.1 500 500 500 16 20 10 273.0 450 450 450 16 20 Figure 12 323.9 450 450 400 16 20 260 21/2,5 73.0,141.3 500 500 500 - - 76.1 500 - 500 16 20 Figure 260 ., . -,, 165.1 500 - 500 - 20 End Cap °*z. 139.7 500 - 500 16 - 1'/z,x 1,2 x 1 48.3 x 33.7,60.3 x 33.7 500 500 500 16 - 4 2x VA,2x1'h 60.3 x 42.4,60.3 x 48.3 500 500 500 16 20 2'/2 x 2,3 x 2'/z,4 x 2'/z 73.0 x 60.3,88.9 x 73.0,114.3 x 73.0 500 500 _500 16 20 4 x2,6 x 2 114.3 x 60.3,168.3 x 60.3 500 500 500 16 - 3x2,4x3,6x4 88.9 x 60.3,114.3 x88.9,168.3 x114.3 500 500 500 16 20 Figure 5 x4,6 x5 141.3 x 114.3,168.3 x 141.3 500 500 500 - - 250 76.1 x 48.3,76.1 x 60.3 500 500 500 16 20 Ct Figure 250 ' 88.9 x 76.1,114.3 x 76.1 500 500 500 16 20 Concentric 139.7 x 88.9,139.7 x 114.3 500 500 500 16 - Reducer 165.1 x 114.3 500 500 500 - 20 168.3 x 76.1,168.3 x 139.7 500 500 500 16 - • 165.1 x 88.9,165.1 x 139.7 500 - 500 - - * ADACAPs are UL and ULC Listed and FM Approved with NPT and ISO threaded outlets. TFP18OO Page 7 of 8 Rated Pressure Figure 501 Nominal Size Nominal Size (psi-UL,ULC,FM;Bar LPCB and VdS)Elbow -, Figure Inches mm lbUL 0 (VdS) 00320 1'/a,1'/z,2,3,4 42.4,48.3,60.3,88.9,114.3 300 300 FM 300 16 20 6,8 168.3,219.1 300 300 300 16 20 Figure 21/2,5 73.0,141.3 300 300 300 - - 501 76.1 300 300 300 16 20 139.7 300 300 300 16 Figure 510 165.1 300 300 300 - 20 90°Elbow +,a 11/4,1 Vz,2,3,4 42.4,48.3,60.3,88.9,114.3 300 300 300 16 20 s z. 6,8 168.3,219.1 300 300 300 16 20 Figure 21/2,5 73.0,141.3 300 300 300 - - 510 76.1 300 300 300 16 20 139.7 300 300 300 16 - 165.1 300 300 300 - 20 11/a,l Yz,2,3,4 42.4,48.3,60.3,88.9,114.3 300 300 300 16 20 6,8 168.3,219.1 300 300 300 16 20 Figure 519 Figure 21/z,5 73.0,141.3 300 300 300 - - Tee 519 76.1 300 300 300 16 20 139.7 300 300 300 16 - 165.1 300 300 300 - 20 2,3,4,6,8 60.3,88.9,114.3,168.3,219.1 300 300 300 16 20 Figure 501S 21/2,5 73.0,141.3 300 300 300 - - iik45°Elbow `* Figure 76.1 300 300 300 16 20 III ; d 139.7 165.1 300 300 300 16 - 300 300 300 20 8 2,3,4,6,8 60.3,88.9,114.3,168.3,219.1 300 300 300 16 20 2Vz,5 73.0,141.3 300 300 300 - - Figure 5105 76.1 300 300 300 16 20 139.7 300 300 300 16 - Figure 5105 90°Elbow 4 165.1 300 300 300 20 2,3,4,6,8 60.3,88.9,114.3,168.3,219.1 300 300 300 16 20 21/2,5 73.0,141.3 300 300 300 - - Figure 76.1 300 300 300 16 20 519S 139.7 300 300 300 16 - 165.1 300 300 300 - 20 a4 Figure 2'/z,3,4,5 73.0,88.9,114.3,141.3 300 300 300 - - 510DE 6,8 168.3,219.1 300 300 300 - - 9r: Figure 519S Tee Figure 510DE 2 III ` 1f Drain Elbow , i" Y. as TFP78O0 Page 8 of 8 Fabricated Fittings Rated Pressure Rated Pressure Nominal Size (psi) Nominal Size (psi) • Figure Inches Figure Inches U` M VL M 1,1/,1'% 300 300 1''A,11/2 300 300 300 300 Figure 391 2,2Yz 2,2,/z 300 300 Groove x Male Threaded 3,4,5 300 300 Figure 321 Adapter Nipples 6,8 300 300 Reducing Tee 3,4,5 300 300 6,8 300 300 10,12 300 300 10,12 300 300 1,11/4,11/2 300 300 1,11/4,1% 300 300 300 300 Figure 392 2,2% 2 212 300 300 Groove x Groove 3,4,5 300 300 Figure 327 Adapter Nipples Cross 3,4,5 300 300 6,8 300 300 6,8 300 300 10,12 300 300 10,12 300 300 1,1/.1/ 300 300 1,1%,11/2 300 300 Figure 393 2,2Y2 300 300 Figure 341 2,2'/2 300 300 Groove x Bevel 3,4,5 300 300 Groove Adapter Nipples 6,8 300 300 Flange Adapter 3,4,5 300 300 150 lbs. 6,8 300 300 10,12 300 300 10,12 300 300 11/4.11/2 300 300 11/4,1'/2 300 300 2,21/2 300 300 Figure 350 2,212 300 300 Figure 312 3,4,5 300 300 Concentric 221/2i Elbow 3,4,5 300 300 6,8 300 300 Groove x Groove Reducer 6,8 300 300 • 10,12 300 300 10,12 300 300 1'%1'/2 300 300 2,2% 300 300 Figure 313 3,4,5 300 300 11%,°Elbow 6,8 300 300 10,12 300 300 General Notes: It is the Designer's responsibility to select products suitable for the intended service and to en- O�I • sure that pressure ratings and performance n is not eent or Always read and understandgdeftthe installationewith 1-1.P\7001juuti instructions(IH-1000). Never remove any piping component or correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. Certified Company TYCO FIRE&BUILDING PRODUCTS,451 North Cannon Avenue,Lansdale Pennsylvania 19446 C.I. THREADED FITTINGS STAR®PIPEPRODUCTS 0.,1.c.2 0 t U L A I› • LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 Cast iron threaded fittings are UL,ULC listed and factory mutual approved for 300 psi service.Gray iron perASTM A126 class B.Dimensions conform to ANSI B16.4 class 125 except plugs conform toASME B16.14.Threads are NPT per ANSI/ASME B1.20.1. xi - g 1 i El f^ f r, CAST IRON STRAIGHT TEE CAST IRON 90 DEGREE ELBOW NOMINAL ITEM MAX. DIMENSIONS WEIGHT NOMINAL ITEM MAX. DIMENSIONS WEIGHT SIZE CODE WORKING EACH SIZE CODE WORKING EACH (INCH) # P.S.I. A B PIECE (INCH) # P.S.I. A B PIECE 1 CT333 300 1.50 1.50 1.21 1 CB90033 300 1.50 1.50 0.95 11/4 CT444 300 1.75 1.75 1.87 11/4 CB90044 300 1.75 1.75 1.34 11/2 CT555 300 1.94 1.94 2.51 11/2 CB90055 300 1.94 1.94 1.80 2 CT666 300 2.25 2.25 3.96 2 CB90066 300 2.25 2.25 2.90 21/2 CT777 300 2.70 2.70 6.45 21/2 CB90077 300 2.70 2.70 4.75 e r / r i\s, 411 1 K / CAST RON RED. COUPLING r • NOMINAL ITEM MAX. DIMENSION WEIGHT SIZE CODE WORKING EACH CAST IRON 45 DEGREE ELBOW (INCH) # P.S.I. A PIECE NOMINAL ITEM MAX. DIMENSIONS WEIGHT 1X1/2 CRC031 300 1.70 0.62 SIZE CODE WORKING EACH 1X3/4 CRC032 300 1.70 0.80 (INCH) # P.S.I. A B PIECE f _ 1 CB45033 300 1.12 1.12 0.84 1 1/4 C B45044 300 1.29 1.29 1.40 1 1/2 C B45055 300 1.43 1.43 1.80 t 2 CB45066 300 1.68 1.68 2.79 z E CAST IRON RED. 90 DEG. ELBOW NOMINAL ITEM MAX. DIMENSIONS WEIGHT I SIZE CODE WORKING EACH '» t (INCH) # P.S.I. A B PIECE 1X1/2 CB90031 300 1.26 1.36 0.64 1X3/4 CB90032 300 1.37 1.45 0.87 CAST RON PLUGS I1/4X1/2 CB90041 300 1.34 1.53 0.96 NOMINAL ITEM MAX. DIMENSION WEIGHT 1 114X3/4 C B90042 300 1.45 1.62 1.13 1 1/4X1 CB90043 300 1.58 1.67 1.16 SIZE CODE WORKING EACH 1 1/2x1 1/2 CB90051 300 1.41 1.66 1.17 (INCH) # P.S.I. A PIECE 1 1/2x3/4 CB90052 300 1.52 1.75 1.28 1/2 CPL001 300 0.94 0.10 1 1/2X1 CB90053 300 1.65 1.80 1.51 3/4 CPL002 300 1.07 0.17 • 1 1/2X1 1/4 CB90054 300 1.82 1.88 1.62 1 CPL003 300 1.25 0.28 2X1/2 CB90061 300 1.49 1.88 2.00 11/4 CPL004 300 1.36 0.44 2X3/4 CB90062 300 1.60 1.97 2.05 11/2 CPL005 300 1.45 0.62 2X1 CB90063 300 1.73 2.02 2.10 2 CPL006 300 1.56 0.91 2X1 1/4 CB90064 300 1.90 2.10 2.30 2X1 1/2 CB90065 300 2.02 2.16 2.60 Page 19 C.I. THREADED FITTINGS STAR®PIPE PRODUCTSr. 0 LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 CAST IRON CROSS t NOMINAL ITEM MAX. DIMENSIONS WEIGHT 6 0SIZE CODE WORKING EACH r (INCH) # P .I. A B PIECE 1 CX033 300.S 1.50 1.50 1.54 e 11/4 CX044 300 1.75 1.75 2.40 w 11/2 CX055 300 1.94 1.94 3.10 2 CX066 300 2.25 2.25 4.00 1 1/4X1 CX043 300 1.58 1.67 2.05 1 1/2X1 CX053 300 1.65 1.80 2.40 2X1 CX063 300 1.73 2.02 2.75 CAST IRON REDUCING TEE NOMINAL ITEM MAX. DIMENSIONS WEIGHT SIZE CODE WORKING EACH (INCH) # P.S.I. A B C PIECE 1X1X1/2 CT331 300 1.26 1.26 1.36 0.95 1X1X3/4 CT332 300 1.37 1.37 1.45 1.10 1X1/2X1 CT313 300 1.50 1.36 1.50 1.08 1X3/4X1 CT323 300 1.50 1.45 1.50 1.18 • 1X1X1 1/4 CT334 300 1.67 1.67 1.58 1.52 1X1X1 1/2 CT335 300 1.80 1.80 1.65 1.73 1 1/4X1X1/2 CT431 300 1.34 1.26 1.53 1.17 1 114X1 X314 CT432 300 1.45 1.37 1.62 1.38 1 1/4X1 X1 CT433 300 1.58 1.50 1.57 1.47 1 1/4X1X1 1/4 CT434 300 1.75 1.67 1.75 1.80 1 1/4X1X1 1/2 CT435 300 1.88 1.80 1.82 2.05 1 1/4X1 1/4X1/2 CT441 300 1.34 1.34 1.53 1.37 1 1/4X1 1/4X3/4 CT442 300 1.45 1.45 1.62 1.54 1 1/4X1 1/4X1 CT443 300 1.58 1.58 1.67 1.65 1 114X1 1/4X1 1/2 CT445 300 1.88 1.88 1.82 2.21 1 1/4X1 1/4X2 CT446 300 ' 2.10 2.10 1.90 2.55 1 1/2X1 X1/2 CT531 300 1.41 1.34 1.66 1.41 1 1/2X1 X3/4 CT532 300 1.52 1.37 1.75 1.65 1 1/2X1X1 CT533 300 1.65 1.50 1.80 1.65 1 1/2X1X1 1/4 CT534 300 1.82 1.67 1.88 2.00 11/2X1X11/2 CT535 300 1.94 1.80 1.94 2.30 1 1/2X1 114X1/2 CT541 300 1.41 1.34 1.66 1.58 1 1/2X1 114X314 CT542 300 1.52 1.45 1.75 1.72 1 1/2X1 1/4X1 CT543 300 1.65 1.58 1.80 1.85 11/2x11/4x11/4 CT544 300 1.82 1.75 1.88 2.22 1 1/2x1 1/4x1 1/2 CT545 300 1.94 1.88 1.94 2.45 1 1/2X1 1/4X2 CT546 300 2.16 2.10 2.02 2.80 1 1/2X1 1/2X1/2 CT551 300 1.41 1.41 1.66 1.76 1 1/2X1 1/2X3/4 CT552 300 1.52 1.52 1.75 1.87 1 112X1 1/2X1 CT553 300 1.65 1.65 1.80 1.94 1 1/2X1 1/2X1 1/4 CT554 300 1.82 1.82 1.88 2.29 1 1/2X1 1/2X2 CT556 300 2.16 2.16 2.02 3.28 2X1X2 CT636 300 2.25 2.02 2.25 3.40 2X1 1/4X2 CT646 300 2.25 2.10 2.25 2.80 2X1 1/2X1/2 CT651 300 1.49 1.41 1.88 2.09 2X1 1/2X3/4 CT652 300 1.60 1.52 1.97 2.40 2X1 1/2X1 CT653 300 1.73 1.65 2.02 2.54 2X1 1/2X1 1/4 CT654 300 1.90 1.82 2.10 2.85 2X1 1/2X1 1/2 CT655 300 1.49 1.41 1.88 2.24 III 2X1 CT656 300 2.25 2.16 2.25 3.75 2X2X1/2 CT661 300 1.49 1.49 1.88 2.60 2X2X3/4 CT662 300 1.60 1.60 1.97 2.71 2X2X1 CT663 300 1.73 1.73 2.02 2.97 2X2X1 1/4 CT664 300 1.90 1.90 2.10 3.32 2X2X1 1/2 CT665 300 2.02 2.02 2.16 3.72 2x2x2 1/2 CT667 300 2.60 2.60 2.39 5.10 Page 20 • Cam®• Worldwide Contacts www.tyco-fire.com BLAZEMASTER CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet General Technical ! Description Data TYCO CPVC Pipe and Fittings pro- Sizes duced by Johnson Controls are 3/4 Inch to 3 Inch ,gym designed exclusively for use in wet Maximum Working Pressure pipe automatic fire sprinkler systems. 175 psi The TYCO CPVC Pipe and Fittings are produced from BLAZEMASTER CPVC Approvals compound that is a specially developed UL and C-UL Listed thermoplastic compound composed FM Approved of post chlorinated polyvinyl chloride LPCB Approved (CPVC)resin and state of the art addi- NSF Certified �• �- tives.TYCO CPVC Pipe and Fittings are MEA Approved , easier to install than traditional steel (Refer to Installation Handbook IH-1900 °` \ pipe systems, and at the same time, dated April 2016 for exact listing/approval provide superior heat resistance and information.) strength as compared to traditional Manufacture Source Installation • CPVC and PVC piping materials used U.S.A. TYCO CPVC Pipe and Fittings are to in the plumbing trade. Various adapt- be to be installed in accordance with ers are available to connect CPVC Material Installation Handbook IH-1900. pipe to metallic piping.All female pipe Pipe: thread adapters have brass inserts for ASTM F442,SDR 13.5 durability. Grooved adapters connect Fittings: directly to grooved end valves and ASTM F438(Sch.40) metallic pipe,with flexible grooved end ASTM F439(Sch.80) couplings. ASTM F1970 NOTICE O Orange The CPVC Pipe and Fittings produced with BLAZEMASTER CPVC compound described herein must be installed and maintained in compliance with this document and with the applica- ble standards of the NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. • IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Page 1 of 2 AUGUST 2018 TFP1915 TFP1915 Page 2 of 2 Care and Limited Maintenance Warranty TYCO CPVC Pipe and Fittings are to be For warranty terms and conditions,visit maintained and serviced in accordance www.tyco-fire.com. with this section. Before closing a fire protection system control valve for inspection or main- tenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must first be obtained from the proper authorities and all person- nel who may be affected by this action must be notified. After placing a fire protection system in service, notify the proper authorities and advise those responsible for moni- toring proprietary and/or central station alarms. The owner is responsible for the inspec- tion,testing, and maintenance of their fire Y protection system and de-vices in compliance with this document,as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSO- CIATION(e.g., NFPA 25),in addition to the standards of any authority having jurisdiction.Contact the installing con- tractor or product manufacturer with • any questions. Automatic sprinkler systems should be inspected,tested,and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. • 1400 Pennbrook Parkway,Lansdale,PA 19446 Telephone♦1-215-362-0700 l,, e� / .2018 Jehneen Controls.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change witllold notice. Johnson ,li' NATIONAL FIRE PROTECTION ASSOCIATION sad NFPA ere registered eadsmerki at National Fire Protection Asceaiatron. Controls s BLAZEMASTEF Is a trademark at The Whiled Cspontian 1 F 1 Worldwide wwwtyco-fire.com • [IC la Contacts Model BFV-300/BFV-300C Butterfly Valve Grooved End General Technical Description Data r1 r 1. The TYCO Models BFV-300 and BFV- Approvals 0 300C Grooved End Butterfly Valves UL and ULC Listed , are indicating type valves designed for FM Approved use in fire protection systems where CE Certified a visual indication of open or closed VdS Approved valve condition is required. They are Russian Fire Certificate used, for example, as system, sec- CNPP R1 Listed-APSAD tional and pump water control valves. Listed by California State Fire Marshall , They have grooved inlet and outlet con- Refer to Tables A,B and C for applicability. nections that are suitable for use with All laboratory listings and approvals are for grooved end pipe couplings listed or indoor and outdoor use. approved for fire protection systems. j For applications requiring supervi- Sizes MODEL BFV-300 sion of the open or closed state of the 2-12 Inch(DN50-DN300) WITH OPEN SUPERVISORY valve,the Gear Operators for the Model UL/ULC/FM Maximum Working SWITCHES • BFV-300/BFV-300C Butterfly Valves Pressure feature two sets of factory installed 2-8 Inch(DN50-DN200) 300 psi(20,7 bar) internal switches each having SPDT 10-12Inch(DN250-DN300)..175 psi(12,1 bar) ;I contacts (Ref. Figure 3). The super- VdS Maximum Working Pressure ,, ti visory switches transfer their electri- 2-8 Inch(DN50-DN200) 300 psi(20,7 bar) cal contacts when there is movement 101nch(DN250) 232 psi(16,0 bar) 111. from the open or closed disc position 12 Inch(DN300) 175 psi(12,1 bar) during the first two revolutions of the Maximum Working Temperature handwheel. 212°F(100°C)In accordance with UL 1091 NOTICE Materials of Construction Body Ductile Iron The Model BFV-300/BFV-300C Body Coating RILSAN PA11 Black Grooved End Butterfly Valves described Disc Ductile Iron herein must be installed and maintained Disc seal EPDM Encapsulated Upper&Lower Stem Stainless Steel in compliance with this document, as Handwheel Ductile Iron well as with the applicable standards (BFV-300 red painted;BFV-300C black painted) of the National Fire Protection Asso- Actuator,2-6 Inch(ON50-DN150): ciation, in addition to the standards of • IP 65, bronze traveling nut gearbox, ductile MODEL BFV-300C any other authorities having jurisdiction. Iron housing WITH CLOSED SUPERVISORY Failure to do so may,aimpair theperfor- Actuator,8-12 Inch(DN200-DN300): SWITCHES IP 65,brass segmented gearbox,ductile iron mance of these devices. housing The owner is responsible for main- Silicone Free Model Availability 11) r, taming their fire protection system Silicone free models are available.Contact "°' ro� and devices in proper operating con- Tyco sales for information. • � '• P P P g Y �. . ; dition. Contact the installing contrac- c (gro a` �"'for or product manufacturer with any Tapping BossesEA [ S? ps•�wquestions. Two factory-plugged NPT threaded tapping Fa v bosses in the valve body are located on the up-and downstream sides of the disc for connection to valve trim. Tapping boss sizes: VdS All> Cr P 2-3 inch(DN50-DN80) 3/8 NPT ID4-12 inch(DN100-DN300)Control Valve Seat Leakage 1/2 NPT APPROVED Class IEC 60534-4 CLASS VI(Type C)Control Valve Seat Leakage according to ANSI/FCI 70-2-2006(ASME B16.104) Page 1 of 8 JANUARY 2018 TFP1511 TFP1511 Page 2 of 8 Nominal PipeNominal Dimensions Inches Weight • Valve Size OD (mm) Lbs. Inches Inches (kg) (DN) (mm) A B C D E F G H J 2 2.37 3.8 10.63 2.85 4.90 4.92 4.28 1.99 0 0 10.8 (DN50) (60,3) (96,4) (270) (72,5) (124,5) (125) (108,6) (50,5) (4,9) 2-1/2 2.88 3.8 11.72 3.35 5.5 4.92 4.28 1.99 0 0 13.0 (DN65) (73,0) (96,4) (297,8) (85) (139,8) (125) (108,6) (50,5) (5,9) 3 3.8 11.72 3.35 5.5 4.92 4.28 1.99 13.0 (DN65) 76,1 (96,4) (297,8) (85) (139,8) (125) (108,6 (50,5) 0 0 (5,9) 3 3.5 3.8 12.22 3.58 5.76 4.92 4.28 1.99 0 0 13.9 (DN80) (88,9) (96,4) (310,3) (91) (146,3) (125) (108,6) (50,5) (6,3) 4 4.5 4.54 13.92 4.29 6.75 4.92 4.28 1.99 0 0 17.64 (DN100) (114,3) (115,4) (353,5) (109) (171,5) (125) (108,6) (50,5) (8,0) 5.5 5.83 16 5.16 7.93 5.91 5.79 2.32 0 0 26.4 (DN125) (139,7) (148) (406,6) (131) (201,5) (150) (147) (58,9) (11,9) 5 5.56 5.83 16 5.16 7.93 5.91 5.79 2.32 0 0 26.4 (DN125) (141,3) (148) (406,6) (131) (201,5) (150) (147) (58,9) (11,9) 6.5 5.83 17.07 5.71 8.44 5.91 5.79 2.32 30,42 DN150 165,1 (148) (433,6) (145) (214,5) (150) (147) (58,9) 0 0 (13,8) 6 6.63 5.83 17.07 5.71 8.44 5.91 5.79 2.32 30,42 (DN150) (168,3) (148) (433,6) (145) (214,5) (150) (147) (58,9) 0 0 (13,8) 8 8.63 5.24 19.67 6.69 9.29 8.86 8.19 2.76 5.66 1.24 47.18 (DN200) (219,1) (133) (499,5) (170) (236) (225) (208) (70) (143,7) (31,4) (21,4) 10 10.75 6.26 22.46 7.68 11.1 11.14 8.19 2.91 7.21 1.65 73.41 (DN250) (273) (159) (570,5) (195) (282) (283) (208) (74) (183,1) (41,8) (33,3) 12 12.75 6.5 25.39 9.5 12.2 11.14 8.19 2.91 9.96 2.7 89.29 (DN300) (323,9) (165) (645) (241,5) (310) (283) (208) (74) (252,9) (68,5) (40,5) SEGMENTED HANDWHEEL GEAR OPERATOR 8 TO 12 INCH E INDICATOR (DN200 TO DN300) FLAG II VALVE SIZES • --C D (VALVE ��� �� o 0 CLOSED) -, I / F I 0 s 1 () iiir-- --'s.\\_ C i.-_-_-. MI O MI —TAPPING I ' _ G i �.� BOSSES i�i_ir B HANDWHEEL HANDWHEEL INDICATOR BODY FLAG ��� OPEN) TAPPING _ I � O I *,� jI Y :.■1 BOSSES I, O e;II I _ 0O i TAPPING �! I I. 1 I� BOSSES 1-- J _.-I H DISC :: \ �.� ELECTRICALTRAVELLING NUT 1 TRAVELLING NUT !pi GEAR OPERATOR'' GEAR OPERATOR CONNECTORR 2 TO 4 INCH 5 TO 6 INCH (DN50 TO DN100) (DN125 TO DN150) VALVE SIZES VALVE SIZES FIGURE 1 MODEL BFV-300/BFV-300C GROOVED END BUTTERFLY VALVE NOMINAL DIMENSIONS FP1511 Page 3 of 8 • No. Part Material Qty. No. Part Material Qty. No. Part Material Qty. 01 Body ASTM A-536 1 15 Spring Pin ASTM A-228 1 30 Bolt(Round) ASTM A-167 3 ST 02 Upper Stem AISI 410 1 16 IndicatorA A 6 9 1 31 Plate Washer AS 6 4 03 Lower Stem AISI 410 1 17 0-Ring NBR 1 32 Switch Assembly — 1 04 Disc EPDM 1 18 Cover Gasket Paper 1 33 T/R Bolt ASTM 2 A-307 05 0-Ring(P12) EPDM 4 19 Spring Pin ASTM 1 34 Tapping Screw S10C 1 05x1Tx25 A-228 ST3.5x7.5 Oiless B/R 06 (M61410) — 4 20 0-Ring(P10) EPDM 1 35 Tooth Washer4# S10C 1 07 End Cap EPDM 1 21 Worm Shaft AISI 410 1 36 Lever ASTM 1 2-1/2-4 Inch A-619 08 Gear Box ASTM 1 22 Bushing(1) FD-0205-45 1 37 Connector — 1 A-536 Traveling Nut Bronze 1 23 Collar FD-0205-45 1 38 Sticker — 1 09 2-6 Inch Segment Gear C3604BD 1 24 Spring Washer ASTM 4 39 Sticker — 1 8-12 Inch A-167 10 Bushing(2) FD-0205-45 1 25 Hex Bolt ASTM 2 40 Spring Pin ASTM 1 M8 x 20L A-167 03x0.6Tx25 A-228 11 Cover ASTM 1 26 Hex Bolt ASTM 2 Headless Plug A-619 M8 x 25L A-167 3/8 NPT 12 Bushing Fe 1 27 Gasket Paper 1 41 2-3 Inch ASTM 2 13 Headless Wrench ASTM 1 28 Spring Pin ASTM 1 Headless Plu A-307 g Bolt M5 x 7L A-307 04x0.8tx25 A-228 1/2 NPT 14 Stem Housing Fe 1 29 Handwheel ASTM 1 4-12 Inch A-536 35 34 37 33 30 37 33 35 G•n p1111 ID 36 !1��-`;plc 30 32 .yam.` 34 L. "MI I� � 32 'L tett 36 I.■Iit--,-7ir. 38,39 I_ I7■lilt7(■i�in 38,39 28 o�`.� 31 28 C g�.,' E 31 30 30 19, 19, 29 20 40 17 14 12 18 29 20 40 17 14 12 18 16 16 Illi 11 I 11 15 J .J V 21 ` --�� 10 21 I ` -1*-= 10 15 /��\ ■Iliie■ 13 •� r�7 I,._ '■lillll 1 • r�� 1�=��� . � 3 f"I �.1., 22 0� 09 �is:�ar 1y_ r— T_= t0 'ly-..,� I 271 ■ 27 �._. ■ ._. 23 :� 08 : 23 _. : `.., 08 in. ,I 25AI rII25A.24 OS 1 24 OS i l 25 11402 � 02• 26614 (�) 25 (�) 02• 26 01 41 01 �10IIE 41 -04 i 03 04 ( � 03 ,i' I 06 07 mar 06 I,=r 07 it = BFV-300 Normally Open Valve BFV-300C Normally Closed Valve Supervisory Switch Arrangement Supervisory Switch Arrangement • FIGURE 2 MODEL BFV-300/BFV-300C GROOVED END BUTTERFLY VALVE ASSEMBLY TFP1511 Page 4 of 8 FLOW RATE IN LITERS PER MINUTE(LPM) • (1 GPM=3,785 LPM) 200 400 600 1000 2000 4000 6000 10000 20000 9.0 1 1 I 1 11 I I I I I 11 1 I 0,60 :.: A r' 0,50 . Al' LAI I'1 ,41III 4 IIliva olill 0,40 .moo h �1�1��111ENE���1�����II�►,111111�� 11�11�r•�����������%i111■■u.� : 0,30 ........■ O / 4.0 :::::::: a=G ��IIFi11111■■11 Fill ��111111111:: :I1:1.4FiFi111::■11FiFi11:11111IIIIl1 nm..co Z um. ■ u nor �� ���.■ rr a_ 0.> IIi•• i �y 4111111111111111II1/111111■►I11111111■■11111111111I111111 m a z 2.0 lino ri■■■..■m■■■ . Anonn■unnm-OIIIIvi.Nu PAIMIN •uuUIII.nIIIIII 0,20 z O O Inn ti .IIII■■■IIIII O I I o z 11n1■ AIIII■U■IIIII z IIII 0 111111111111111111111111111111111111111111111111h w w IIIIIUI//INMEMM■■Ill U 4U•I .o RIIII III■■IIIIIMEMENNIA11■■■■NNIIIIIIIIIIP II 03 Q Q 11111■/ 111111■■■■II 2 ► EM = 111 o I IIUUIIII1IUUU■■IIIII■■■■■I11111111111111 0 to ] Q 2.0 �..■■ ■�.. O ,iu■ O ■ .■ mum N D ...■ ry uag.. ■■■ 4 NU 1►I6■_■_■�I/tllll■■■CI■■11111■■�n.u. w 0 LLI 0)cc niiiii "rnm• .V'rin■�°_,� �ti , Ill 1111111l■h111111111P111IIIl CO o w 11111��uuuuui���EN�IA���� O II�� OS ��IIIII O$ 411: o LIIIIIO..I. I�4IIIII 1 0,10 w u a 11,111■.IIIIII■■■IIIIIII■■■III - 1111111 ` fill ,-- ,I1111111111111111/1111111111 0,09 a c z 0 I,IIuI•UIIIIII■■■■I/IIII■■■III °` '/11111 O�RIIII ., MENNIIIII■■■IIIII1/11111►1111 0,08 _1 a p 0 1.0 IiIiIUI■IIIIsm I IMENNI111 mm 1••II■III� ►111111 h liii z •UUlII IIMINUIINIFAII iI IMI 0,07 z = Z 0 nnuu■oo...ri somm Mn..■ ■ uo■ . r...00■o... 0,06 a n . 0 0.8 ■ ... r.. I,l..■ ..Oo■o 9I... u.o ....■ . •o n■...uoo■.. .y r• o I z IIIII•uuuuiui.■a•IIIIIIII.•.II%IIIIIIIIIri11uu■ ■■..•u•IIIII.. Z I 'o III III 0,05 0.7 IIIIIMIIIII./:MMIIIIIIN.III//IIII.IIIn111IIIIIUO..IIIIIIII. O , n , 4 0.6 IIIII■IIIIIII■/IIIIIIIIhUU■IIIIIIIIIIIIIIIII■IIILlIIUUIIII!!!I! I p= ,/11 0c, Al 0,04 S:IC ,,....::III.'::::CIC: U d .. ., :: ■..,:,.IL: .II. .. U d::-`O /.111I 0.5 ■■.r.■._Am �,. .....:=..:...■:MIM v � 2 C:::,. IIII.. on .......■■■L■.....■'I■■■.... ......■■■■■.. ..l , n■■ 2U r, 0,03 .......■■■I■.... ..S.■ iu..m.n.■■u■.. .n ^ ,�■■ 0.4 .....I/■■■■�L.■ ■......■■■ .rI ■■ .. .u.....urllu. urn..■ '' . . u.. ■ ...■ru■ •b . III.. • .uu..Mru■....no■■■�r • .. nu...lo ^ ' 0.3 r " I I ( " 50 60 80 100 200 400 600 800 1000 2000 4000 6000 FLOW RATE IN GALLONS PER MINUTE(GPM) GRAPH A MODEL BFV-300/BFV-300C GROOVED END BUTTERFLY VALVE NOMINAL PRESSURE DROP VERSUS FLOW YELLOW ( YELLOW I S-1 u I FIRE ALARM COMMON HIT ;p COMMON(WHITE) END OF LINE CONTROL PANEL RESISTOR SUPERVISORY RED ' 1 RED OR CIRCUIT I NEXT DEVICE MODEL BFV-300/BFV-300C I O I GREEN GEAR OPERATOR 1 OPERATOR CASE CONTACT RATINGS: - GROUND 16A 125V/250 VAC I BLUE 5A 24VDC I SWITCH S-1,2 LEADS PER CONTACT SWITCH S-2,1 LEAD PER CONTACT S-2 COMMON(BLACK) I I ORANGE VOLTAGE L_____J AUX. DEVICE SOURCE - . (BELL OR HORN) FIGURE 3 MODEL BFV-300 BUTTERFLY VALVE OPEN POSITION-SUPERVISORY SWITCH OPEN POSITION MODEL BFV-300C BUTTERFLY VALVE CLOSED POSITION-SUPERVISORY SWITCH CLOSED POSITION INTERNAL SWITCH WIRING DIAGRAM • FP1511 Page 5 of 8 • Nominal Pipe Max. Part Number Agency Listing/Approval Russian Valve Size O.D. PSI BFV-300 BFV-300C CA Fire Inches Inches Supv.Switch Supv.Switch CE UL ULC FM VdS CNPP PAVUS Fire (ON) (mm) (bar) OPEN CLOSED Marshall Cert. 2 2.38 300 59300G020WS 59300G020WSC ✓ ✓ ✓ / ✓ ✓ (DN50) (60,3) (20,7) 2-1/2 2.88 300 59300G025WS 59300G025WSC ✓ ✓ I I ✓ / ✓ ✓ (DN65) (73,0) (20,7) - 3 300 59300G026WS 593000026WSC / / ✓ / / ✓ ✓ DN65 76,1 (20,7) 3 3,5 300 59300G030WS 59300G030WSC / ✓ ✓ / / / ✓ ✓ (DN80) (88,9) (20,7) 4 4.5 300 59300G040WS 59300G040WSC / / ✓ ✓ / / ✓ ✓ (DN100) (114,3) (20,7) - 5.5 300 59300G056WS 593000056WSC / I ✓ I ✓ ✓ ✓ DN125 (139,7) (20,7) 5 5.56 300 59300G050WS 59300G050WSC / ✓ ✓ ✓ ✓ ✓ ✓ ,/ (DN125) (141,3) (20,7) 6.5 300 59300G066WS 59300G066WSC ✓ ✓ I ✓ ✓ ✓ ✓ DN150 (165,1) (20,7) 6 6.63 300 59300G060WS 59300G060WSC ✓ ✓ ✓ / / ✓ ✓ ✓ (DN150) (168,3) (20,7) 8 8.63 300 59300G080WS 59300G080WSC / ✓ ✓ I ✓ ✓ ✓ ✓ (DN200) (219,1) (20,7) 10 10.75 175 59300G100WS 59300G100WSC ✓ ✓ ✓ / / ✓ ✓ ✓ (DN250) (273) (12,1) 12 12.75 175 59300G120WS 59300G120WSC ✓ 1 7 ✓ 7 ✓ (DN300) 323,9 (12,1) TABLE A MODEL BFV-300/BFV-300C GROOVED END BUTTERFLY VALVE WITH INTERNAL SUPERVISORY SWITCHES PART NUMBER SELECTION AND AGENCY LISTINGS/APPROVALS • Nominal Pipe Max. Part Number Agency Listing/Approval Valve Size O.D. PSI BFV-300 BFV-300C InchesN Inches (bar) Su OPENtch S CLOSED Switch CE VdS CNPP 2 2.38 300 59300G020AWS 59300G020AWSC 7 ✓ 7 (DN50) (60,3) (20,7) 2-1/2 2.88 300 59300G025AWS 59300G025AWSC ✓ 7 ✓ (DN65) (73,0) (20,7) - 3 300 59300G026AWS 59300G026AWSC 1 / ✓ DN65 76,1 (20,7) 3 3,5 300 59300G030AWS 59300G030AWSC 7 7 ✓ (DN80) (88,9) (20,7) 4 4.5 300 59300G040AWS 59300G040AWSC 1 / ✓ (DN100) (114,3) (20,7) - DN125 (15.5 (20,030 ) 59300G056AWS 59300G056AWSC ✓ / ,/ 5 5.56 300 59300G050AWS 59300G050AWSC / / 7 (DN125) (141,3) (20,7) - 6.5 300 59300G066AWS 59300G066AWSC / ✓ ✓ DN150 (165,1) (20,7) 6 6.63 300 59300G060AWS 59300G060AWSC ✓ / ✓ (DN150) (168,3) (20,7) 8 (DN200) (219,1) (200) 59300G080AWS 59300G080AWSC / / ✓ 10 10.75 175 59300G100AWS 59300G100AWSC ✓ / 7 (DN250) (273) (12,1) 12 12.75 175 59300G120AWS 59300G120AWSC / 7 ✓ (DN300) 323,9 (12,1) TABLE B MODEL BFV-300/BFV-300C GROOVED END BUTTERFLY VALVE WITH CNPP-APSAD LARGE 100 X 100 MM FLAG AND INTERNAL SUPERVISORY SWITCHES PART NUMBER SELECTION AND AGENCY LISTINGS/APPROVALS • TFP1511 Page 6 of 8 Nominal Pi a Agency Listing/Approval Valve Size O.D. Max. Part Russian PSI CA Fire • Inches Inches (bar) Number CE UL ULC FM VdS Marshall CNPP PAVUS Fire (DN) (mm) Cert. 2 2.38 300 59300G020NS I ✓ I ✓ I ✓ (DN50) (60,3) (20,7) , 2-1/2 2.88 300 59300G025NS ✓ ✓ ✓ ✓ ✓ ✓ 1 ✓ (DN65) (73,0) (20,7) 3 300 59300G026NS ✓ ✓ ✓ ✓ ✓ ✓ / DN6-5 76,1 (20,7) 3 3,5 300 59300G030NS ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ (DN80) (88,9) (20,7) 4 4.5 300 59300G040NS ✓ ✓ ✓ ✓ 1 ✓ ✓ I (DN100) (114,3) (20,7) 5.5 300 59300G056NS ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN1-25 (139,7) (20,7) 5 5.56 300 59300G05ONS ✓ ✓ ✓ ✓ ✓ ✓ I I (DN125) (141,3) (20,7) 6.5 300 59300G066NS ✓ ✓ I ✓ ✓ I ✓ DN1-50 (165,1) (20,7) 6 6.63 300 59300G060NS ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ (DN150) (168,3) (20,7) 8 8.63 300 59300G080NS I ✓ ✓ ✓ ✓ 1 ✓ ✓ (DN200) (219,1) (20,7) 10 10.75 175 59300G100NS ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ (DN250) (273) (12,1) 12 12.75 175 59300G120NS I ✓ ✓ I ✓ ✓ (DN300) 323,9 (12,1) TABLE C MODEL BFV-300 GROOVED END BUTTERFLY VALVE WITHOUT INTERNAL SUPERVISORY SWITCHES PART NUMBER SELECTION AND AGENCY LISTINGS/APPROVALS Part Number III Bernstein Gear Bernstein Valve Size Mounting Bernstein GC-SU1Z Operator i88-IP65 Inches Type Bracket with i88-1P65 LED Switch Ex IP-66/67 ATEX (DN) Mounting Bolts Regularular Switch 24V (Ex 112G Ex d11C T6 Gb) Switch 2-4 • 59300SPBRACKET10 (DN50-DN100) Travelling 5-6 Nut 59300SPBRACKET20 (DN125-DN200) 59300SPSW 59300SPSWLED 59300SPSWATEX 8 59300SPBRACKET25 (DN200) Segmented 10-12 Gear 59300SPB RAC KET30 (DN250-DN300) Notes: 1. Install a single switch in either bracket mounting position to monitor Open or Closed valve condition I1, - r r z.,, 0 0 L_-_-_J 400 I Or le Bernstein Switch I Wiring Diagram TABLE D MODEL BFV-300 GROOVED END BUTTERFLY VALVE WITHOUT INTERNAL SUPERVISORY SWITCHES ACCESSORY EXTERNAL SUPERVISORY SWITCHES AND MOUNTING BRACKETS PART NUMBER SELECTION 0 FP1511 Page 7 of 8 • Installation Nominal Valve Size Part Number Inches BFV-300,Red Painted BFV-300C,Black Painted The Model BFV-300/BFV-300C (DN) Grooved End Butterfly Valves may be 2-4 59300SPHWHEEL10 59300SPHWHEEL1OB installed with flow in either direction (DN50-DN100) and can be positioned either horizon- 5-8 59300SPHWHEEL20 59300SPHWHEEL2OB tally or vertically. (DN125-DN200) 10-12 59300SPHWHEEL30 59300SPHWHEEL3OB The grooved end pipe couplings (DN250-DN300) used with the Model BFV-300/BFV- TABLE E 300C must be listed or approved for BFV-300/BFV-300C GROOVED END BUTTERFLY VALVE fire protection service and installed in REPLACEMENT HANDWHEEL accordance with the manufacturers PART NUMBER SELECTION instructions. The Model BFV-300/BFV-300C But- Limited Accessories terfly Valve may be installed with any schedule of pressure class of pipe or External Supervisory Switch and tubing that is listed or approved for fire Warranty Mounting Bracket protection. For warranty terms and conditions,visit Note: Accessory external supervi- Conduit and electrical connections www.tyco-fire.com. sory switches and mounting brackets are to be made in accordance with are applicable only to valves without the authority having jurisdiction and/ factory-installed internal supervisory or the National Electrical Code. With Ordering switches. reference to Figure 3, the supervisory Procedure Refer to Table D for switch models and switch is intended for connection to part numbers. the supervisory circuit of a fire alarm Contact your local distributor for avail- control panel in accordance with NFPA ability.When placing an order,indicate Specify:(specify size) Model BFV-300 72.The auxiliary switch is intended for the full product name and Part Number Grooved End Butterfly Valve Exter- the unsupervised connection to aux- (PIN). nal Switch Mounting Bracket, P/N iliary equipment in accordance with (specify), with(specify quantity) Bern- NFPA 70, National Electric Code. Butterfly Valves stein External Switch (specify model), P/N(specify) • NOTE: For outdoor applications with Model BFV-300 with Internal internal supervisory switches, it is rec- Open Supervisory Switches Replacement Parts ommended that wiring connections Specify:(specify size) Model BFV-300 Note: Only items described in this be made at a temperature above 15°F Grooved End Butterfly Valve, Inter- section are offered as replacement (-9 C),in order to insure sufficient flex- nal Open Supervisory Switches, parts. ibility of the wire lead insulation. P/N(specify per Table A) Model BFV-300C with Internal Handwheel Care and Closed Supervisory Switches Replacement handwheel includes pin. Specify: (specify size) Model BFV- 300C to Table E for part numbers. Maintenance 300C Grooved End Butterfly Valve, Model BFV-300,Red Painted Before closing a fire protection system Internal Closed Supervisory Switches, Specify: Handwheel, (specify size) control valve for maintenance or P/N(specify per Table A) Model BFV-300 Grooved End Butter- inspection work on either the valve or Model BFV-300 with Internal fly Valve, P/N(specify) fire protection system which it con- Open Supervisory Switches, Model BFV-300C, Black Painted trols, permission to shut down the APSAD Approved Specify: Handwheel, (specify size) affected fire protection systems must Specify: (specify size) Model BFV-300 Model BFV-300C Grooved End But- be obtained from the proper authorities Grooved End Butterfly Valve, Internal terfly Valve, P/N(specify) and all personnel who may be affected Open Supervisory Switches, APSAD by this decision must be notified. Approved, P/N(specify per Table B) The owner is responsible for the Model BFV-300C with Internal inspection,testing,and maintenance of Closed Supervisory Switches, their fire protection system and devices APSAD Approved in accordance with the applicable stan- Specify: (specify size) Model dards of the National Fire Protection BFV-300C Grooved End Butter- Association(e.g., NFPA 25),in addition fly Valve, Internal Closed Supervi- to the standards of any authority having sory Switches, APSAD Approved, jurisdiction.Contact the installing con- P/N(specify per Table B) tractor or product manufacturer with any questions. Any impairment must Model BFV-300 without Internal be immediately corrected. Supervisory Switches It is recommended that automatic Specify:(specify size) Model BFV-300 • sprinkler systems be inspected,tested, Grooved End Butterfly Valve, and maintained by a qualified inspec- P/N(specify per Table C) tion service. tqco Worldwide www.tyco-fire.com . Fire Protection Contacts Products Model CV-IF Grooved End Swing Check Valves General The owner is responsible for main- taining their fire protection system •_ Description and devices in proper operating con- dition. Contact the installing contrac- 1 The TYCO Model CV-1F Grooved End tor or product manufacturer with any Swing Check Valves are compact questions. , and rugged swing-type units that . allow water flow in one direction and Technical prevent flow in the opposite direction. A resilient elastomer seal facing on the Data spring-loaded clapper ensures a leak- tight seal and non-sticking operation. Approvals The Model CV-1F Check Valves are Compliance with CE Pressure designed to minimize water hammer Equipment Directive(PED)and caused flow Freversal. •Standards12 o Engineering Practice ® C The Model CV-1F Grooved End Swing • 2 to 12 Inch(DN50 to DN300): (20 <11111111'. Check Valves are furnished with UL and C-UL Listed, FM Approved, grooved ends and can be installed Bureau Veritas APPROVED using GRINNELL Grooved Couplings •• or GRINNELL Figure 71 Flange Adapt- 2 to r Inch(DN65 to DN250): 1 Vd/2 5 Approved m , ` ers. The Model CV-1F Check Valves Certificate No.G4060018 Uds� r" 1 have been designed with a removable —i cover for ease of field maintenance. Sizes For fire protection pressure rating, These valves can be installed horizon- 2 to 12 Inch(DN50 to DN300) listing and approval information,contact tally(with cover in the upward position) your TYCO representative. Maximum Working Pressure or vertically with the flow in the upward direction(Ref. Figure 3). UL/FM-300 psi(20,7 bar) Installation VdS- 16 bar A check valve maintenance kit is avail- Valve Assembly Finish The Model CV-1F Grooved End Swing able to allow backflushing through a Red,non-lead paint Check Valves are to be installed in fire department connection without accordance with this section: removing the Model CV-1F Grooved End Swing Check Valve from the riser. Step 1. The arrow cast on the body Refer to technical data sheet TFP1555. must point in the direction of the flow. Model CV-1F is a re-designation for Step 2. Valves installed vertically Central Figure 590F and GRINNELL must be positioned with the flow in the Figure 590F Grooved End Swing Check upward direction. Valves. Step 3. Valves installed horizontally NOTICE must be positioned with the cover facing up(Ref. Figure 3). The TYCO Model CV-1F Grooved End Swing Check Valves described herein used with4 Grooved ende pipe couplings must be installed and maintained in used the Model VaClves must be compliance with this document and End Swing Check Valves must be with the applicable standards of the installed in accordance with manufac- National Fire Protection Association turer's instructions. (NFPA), in addition to the standards Note:Valves should be installed a rea- of any authorities having jurisdiction. sonable distance downstream from Failure to do so may impair the perfor- pumps, elbows, expanders, reducers, mance of these devices. or other similar devices to extend the Never remove any piping component valve life.Standard piping practices call • nor correct or modify an i in deft fora minimum of five times the pipe y g p p diameter for general use. ciencies without first de pressurizing and draining the system. Failure to do so may result in serious personal injury, property damage, and/or impaired device performance. Page 1 of 6 FEBRUARY 2016 TFP155O TFP1550 Page 2 of 6 Nominal Dimensions • Nominal Pipe Size Inch Cover Approx. (mm) Bolt Weight Torque Lbs. Valve Size Pipe O.O. Lbs.-ft. (kg) Inch Inch A B C D E F J (Nm) (DN) (mm) 2 2.37 6.75 1.96 1.96 2.57 3.25 4.75 1.62 18 9.0 (50) (60,3) (171,5) (49,8) (49,8) (65,3) (82,3) (120,7) (41,5) (25) (4,5) 2-1/2 2.88 8.00 5.38 2.63 3.09 3.87 5.87 1.63 39 10.0 (65) (73,0) (203,2) (136,7) (66,7) (78,5) (98,3) (149,1) (41,7) (54) (4,5) 76,1 mm 3.00 8.00 5.38 2.63 3.09 3.87 5.87 1.63 39 10.0 (65) (76,1) (203,2) (136,7) (66,7) (78,5) (98,3) (149,1) (41,7) (54) (4,5) 3 3.50 8.37 5.72 2.81 3.31 3.87 5.87 1.63 39 11.0 (80) (88,9) (212,6) (145,3) (71,4) (84,1) (98,3) (149,1) (41,7) (54) (5,0) 4 4.50 9.63 6.68 3.80 3.63 4.53 7.13 1.84 50 25.0 (100) (114,3) (244,6) (169,7) (96,5) (92,2) (115,4) (181,1) (46,7) (69) (11,3) 139,7 mm 5.50 10.50 7.40 4.46 4.13 4.90 7.50 1.75 39 29.0 (125) (139,7) (266,7) (188,0) (113,3) (104,9) (124,5) (190,5) (44,5) (54) (13,2) 5 5.56 10.50 7.40 4.46 4.13 4.90 7.50 1.75 39 29.0 (125) (141,3) (266,7) (188,0) (113,3) (104,9) (124,5) (190,5) (44,5) (54) (13,2) 165,1 mm 6.50 11.50 8.00 4.62 4.50 5.00 7.60 1.85 60 47.0 1 (150) (165,1) (292,1) (203,2) (117,3) (114,3) (127,0) (193,0) (47,0) (82) (21,3) 6 6.63 11.50 8.00 4.62 4.50 5.00 7.60 1.85 60 47.0 (150) (168,3) (292,1) (203,2) (117,3) (114,3) (127,0) (193,0) (47,0) (82) (21,3) 8 8.63 14.00 10.14 6.67 5.52 5.46 8.46 2.13 120 66.0 (200) (219,1) (355,6) (257,8) (169,4) (140,2) (138,7) (214,9) (54,1) (164) (29,9) 10 10.75 18.00 12.38 8.62 6.41 7.50 10.50 3.00 130 109.7 (250) (273,1) (457,2) (314,5) (218,9) (162,8) (190,5) (266,7) (76,2) (178) (49,4) 12 12.75 21.00 14.28 9.93 7.27 7.62 10.62 2.75 130 151.0 (300) (323,9) (533,4) (362,7) (252,2) (184,7) (193,5) (269,7) (69,9) (178) (68,0) .■ B ■■ ....A I.. • o ° IIIk I II 0 4m Ill 0.D.IlL On .rs 1 -6- MI j 1/2" NPT 1/2" J --- NPT E F - FIGURE 1 MODEL CV-1F GROOVED END SWING CHECK VALVES NOMINAL DIMENSIONS Care and system from the proper authorities of the National Fire Protection Associa- and notify all personnel who may be tion (e.g., NFPA 25), in addition to the Maintenance affected by this decision. standards of any authority having juris- After placing a fire protection system diction.Contact the installing contrac- The TYCO Model CV-1F Grooved End in service, notify the proper authorities tor or product manufacturer with any Swing Check Valves must be main- and advise those responsible for moni- questions. Any impairments must be tamed and serviced in accordance with toring proprietary and/or central station immediately corrected. this section. alarms. Automatic sprinkler systems are rec- Before closing a fire protection system The owner is responsible for the ommended to be inspected, tested, • main control valve for maintenance inspection,testing,and maintenance of and maintained by a qualified Inspec- work on the fire protection system their fire protection system and devices tion Service in accordance with local that it controls, obtain permission to in compliance with this document, as requirements and/or national codes. shut down the affected fire protection well as with the applicable standards TFP1550 Page 3 of 6 • No. Part Material Qty. No. Part Material Qty. No. Part Material Qty. 1 Body Ductile Iron 1 6 ClapperFacingEPDM 1 14 Locknut Stainless 1 Grade"E" Steel 2 Cover Ductile Iron 1 7 Spring Stainless 1 15 Plug Cast Iron 2 Steel 1/2"NPT 3 Cover Gasket Nitrite 1 8 Hinge Shaft Stainless 1 16 Adhesive Thread AR Rubber Steel Sealer 4 Hex Cap Screw Zinc Pl Steeatl,ed AR 9 Retaining g S Ring Stainlessteel Nameplate 17 N late Aluminum 1 Clapper,2"-8" Stainless Stainless 5 (DN50-200) Steel 1 11 Retention Bolt Steel 1 18 Rivet Steel 2 Clapper,10"-12" Ductile Iron 13 RetainingDisc Stainless 1 19 Spacer Stainless 1 (DN250-300) Steel p Steel 8 4,16 18 17 9 CIIt'!Ifffl ll1111111111. 5 8 IIIIIIIIIIII"IlIfl/"/IIpJIIII .. _ s 2 SEE 2 7 9 VIEW A �� 3 2"-8" 2 10" -12' 7 5 (DN50-DN200) (DN250-DN300) ill VIEW A 13 I 5 e 13 or i► SEE / 11,16 DETAIL B 11 I �Us] 14,16 YYYY■ % I %`i 19 y 6 5I /6 �. 1 15 10"- 12" (DN50-DN200) (DN250-DN300) DETAIL B • FIGURE 2 MODEL CV-1F GROOVED END SWING CHECK VALVES ASSEMBLY FLOW RATE IN LITERS PER MINUTE(LPM) (1 GPM=3,785 LPM) 500 700 1000 2000 3000 5000 7000 10000 20000 30000 50000 5.0 UIjIjull 1i) J1J i I I It I 1 lit IIIIU JUt IJ 1 ) 1U I l i 1/}l 1 I l ll 'I'll ) _ 4.0 ��� �_ royo / // - --0,30 lq nrvi ■��'I�amYtip.�m d Zcc a� 3.0 U , U. `O/ �� AWIIIIIIIr / m O= 2 = . .. h `0,20 m a[U N ry ' U O . ,ry S' / / Z �w ti� 7/ Ulf O2 q - 0¢ cc Q 2.0 ���� ' Q CQ�a�11111 - _ p el (/N)D iiii a 7 ?U Ur 2n'M p ¢ o°'o w co —i����-� y 2 O h a III / 2U� .. p= 0,09 0 W u c / f CO Ur -0,08 a cn z0 1.0 ? U 007 Jo 0.9 / ,9 Z I� / ' `� 0,06 Z zp 0.8 c M ? 0.7 , H �� rilf 1 Q05 0.6 " _0,04 0.5 _ I Fr . 100 200 300 400 600 1000 2000 3000 4000 6000 10000 15000 FLOW RATE IN GALLONS PER MINUTE(GPM) • GRAPH A MODEL CV-1F GROOVED END SWING CHECK VALVES NOMINAL PRESSURE LOSS VS.FLOW TFP1550 Page 4 of 6 Valve Size Pipe O.D. • Inch Inch Part Number (DN) (mm) 2 2.37 (50) (60,3) 59-590-0-020 2-1/2 2.88 59-590-0-025 (65) (73,0) 76,1 mm 3.00 59-590-0-076 (65) (76,1) 3 3.50 59-590-0-030 (80) (88,9) 4 4.50 59-590-0-040 (100) (114,3) 139,7 mm 5.50 59-590-0-139 (125) (139,7) 5 (125) (453) 59-590-0-050 165,1 mm 6.50 59-590-0-165 (150) (165,1) 6 6.63 59-590-0-060 (150) (168,3) I 8 8.63 59-590-0-080 (200) (219,1) 10 10.75 59-590-0-100 (250) (273,1) 12 12.75 59-590-0-120 (300) (323,9) TABLE A MODEL CV-IF GROOVED END SWING CHECK VALVES PART NUMBER SELECTION • Valve Size Pipe O.D. Cover Gasket Part Number Clapper Facing Part Number Clapper Assembly Part Number Inch Inch (DN) (mm) Americas Only EMEA/APAC Americas Only EMEA/APAC Americas Only EMEA/APAC (2 (2.37) 595907020 97670501 59020EPDM 59020EPDM 97670201A 97670201 2-1/2 2.88 595907030 97561801 59025EPDME 59025EPDM 97562801A 97562065 (65) (73,0) 76,1 mm 3.00 595907030 97561801 59025EPDME 59025EPDM — 97562801 (65) (76,1) 3 3.50 595907030 97561801 59030EPDME 59030EPDM 97562201A 97562201 (80) (88,9) 4 4.50 595907040 97512001 59040EPDME 59040EPDM 97549001A 97549001 (100) (114,3) 139,7 mm 5.50 595907040 97512001 59050EPDME 59050EPDM — 97565501 (125) (139,7) 5 (125) (1 .56 595907040 97512001 59050EPDME 59050EPDM 97565501A 97562125 165,1 mm 6.50 595907060 97521801 59060EPDME 59060EPDM — 97524101 (150) (165,1) 6 6.63 595907060 97521801 59060EPDME 59060EPDM 97524101A 97562150 (150) (168,3) 8 (200) (2.63) 595907080 97547901 59080EPDME 59080EPDM 97592201A 97592201 10 10.75 595907100 97600001 59100EPDM 59100EPDM 97598001A 97598001 (250) (273,1) 12 12.75 595907120 97600002 59120EPDM 59120EPDM 97647701A 97647701 (300) (323,9) TABLE B • MODEL CV-1F GROOVED END SWING CHECK VALVES REPLACEMENT VALVE PARTS PART NUMBER SELECTION TFP1550 Page 5 of 6 • OUTLET Limited Ordering Warranty Procedure 0I 3 For warranty terms and conditions,visit Contact your local distributor for avail- COVERo www.tyco-fire.com. ability.When placing an order, indicate I� t or. " the full product name and Part Number (P/N). Model CV-1F Check Valve INLET Specify: Model CV-1F Grooved End VERTICAL ORIENTATION Swing Check Valve, size (specify), P/N (specify per Table A) COVER FLOW Replacement Valve Parts Refer to Figure 2 to identify Parts. Cover Gasket Specify: Model CV-1F Grooved End INLET 0 II OUTLET Swing Check Valve,Cover Gasket,size (specify), P/N(specify per Table B) Clapper Facing HORIZONTAL ORIENTATION Specify: Model CV-1F Grooved End FIGURE3 Swing Check Valve, Clapper Seal MODEL CV-IF GROOVED END Facing, EPDM Grade"E",size(specify), SWING CHECK VALVES P/N(specify per Table B) PROPER ORIENTATION Clapper Assembly Includes items 2, 3, 5-14, and 17-19. Specify: Model CV-1F Grooved End Swing Check Valve,Clapper Assembly, size(specify), P/N(specify per Table B) • • Bulletin 617 Rev. E co ® Model CR Commercial Riser Riser Manifold for cr),„: Commercial Applications Available Sizes/Pressure Ratings: 11/2"(40mm) and 2"(50mm) Threaded - 250 0,1 psi (17.2 bar) Working Pressure 2"(50mm),2Y2"(65mm),&3"(80mm)Grooved-300 psi(20.7 bar)Working Pressure 4"(100mm), 6"(150mm), &8"(200mm)Grooved- 300 psi(20.7 bar)Working Pressure Features 1. Cast stainless steel body construction for threaded manifolds. 2. Painted,cast ductile iron body construction for grooved 1.4 manifolds. 3. Brass and galvanized Trim. 4. Factory assembled and pressure tested. 24 VDC. See Table 3 for triggering flow rates. 5. Available with Test and Drain Valves in various orifice • Basic Trim with Pressure Relief Kit sizes. Grooved end Test and Drain valves are available Commercial riser manifold assembly includes a cU- as MTO. Lus Listed pressure gauge, a 1/4" three-way valve, a 6. Optional Pressure Relief Valve Kit available for all sizes. drain (ball)valve, and a dedicated waterflow detector • 7. Same take-out dimensions for the 11/2"(40mm) and containing two sets of SPDT (Form C) contacts, hav- 2"(50mm)threaded sizes. ing an electrical rating of 10A @ 125/250 VAC/2.5 A 8. Same end-to-end dimensions for the 2"(50mm)through 24 VDC.See Table 3 for triggering flow rates.The non- 8"(200mm)grooved sizes. adj(2)ustable Pressure Relief Kit will maintain system 9. Approved for installation in horizontal or vertical posi- pressures below 175 psi (12.1 bar). tions. • Basic Trim with Test and Drain Valves Valve 10. Built in drain port allows hydrostatic testing without Commercial riser manifold assembly includes a cU- draining the system. Lus Listed pressure gauge, a 1/4" three-way valve, a 11. 1/4"three-way valve allows for easy testing and replacing Test and Drain Valve, and a dedicated waterflow de- of pressure gauge. tector containing two sets of SPDT(Form C)contacts, 12. Dedicated cULus Listed, ULC Listed and FM Approved having an electrical rating of 10A @ 125/250 VAC/2.5 Waterflow Detector assures optimum sensitivity. See A @ 24 VDC. See Table 3 for triggering flow rates.The Table 3 for triggering flow rates. available test orifice size inside the Test and Drain Valve are Product Description (Choose one): The Model CR Commercial Riser comes factory aysem- . 3/e" (K-2.8) (1) bled with the necessary accessories for a cost effective,yet complete riser assembly. These assemblies are UL Listed, • 7/1s" (K-4.2) ULC Listed and FM Approved as a unit. • 1/2" (K-5.6) Cast-on lettering on the manifold identifies manifold pipe • »/sz" (K-8.0) size, flow direction, gauge and drain outlets, and UL Listing and FM Approval markings. • 5/8" (K-11.2)(3) The Model CR Commercial Riser is available in four con- • 3/4" (K-14.0)(3) figurations(see Figures 1 and 2): • Basic Trim • 15/16" (K-16.8)(2)(3) Commercial riser manifold assembly includes a cU • 15/s4" (K-22.4)(2)(3) • Lus Listed pressure gauge, a 1/4" three-way valve, a • 1 /s4" (K-25.2)Iz)13) drain (ball)valve, and a dedicated waterflow detector 11) • Not available for 4",6"and 8"risers. containing two sets of SPDT (Form C) contacts, hay- (2)Not available for 1'/2"to 3" risers. ing an electrical rating of 10A© 125/250 VAC/2.5 A C? (3)Not available for 1'/2"to 2"threaded&2"grooved risers. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 THREADED ENDS ASSEMBLIES (1-1/2"(40MM) &2"(50MM) ONLY) B • B D D 3-WAY REDUCING 3-WAY +I RELIEF URE VALVE TEE VALVE IIGy jaj KIT .1:Im;:'a a'E'rr� iid1� •.:I0�:1i 7 0 1111 i 1 E G i _ i PRESSURE J''• • � � il,al (TAKEOUT) PRESSURE J'"M• I2- ,I (TAKEOUT GAUGE —■ O i GAUGE —■®.y ) II r MI m , A �111� A OIIUU N Q 1 ■_ v BALL BALL /m- VALVE n�_• VALVE WATERFLOWJ MANIFOLD I--C (DRAIN WATERFLOWJ MANIFOLDF—C--i (DRAIN DETECTOR BODY CONNECTION) DETECTOR BODY CONNECTION) BASIC ASSEMBLY(2"(50MM)VERSION SHOWN) BASIC ASSEMBLY WITH PRESSURE RELIEF KIT SEE TABLE 1. (2"(50MM)VERSION SHOWN)SEE TABLE 1. B B PRESSURE D GAUGE PRESSURE D - 3-WAY I GAUGE 3-WAY VALVE I %,Ca:( VALVE 1 r \ : 1II11 .�:IC�j:'I .-0 II _ .�.�.�� • 40 A 1 A� (TAKE OUT) m. CJ II �� E �,� .' _ �� (TAKE OUT) II V' mI ritr LO•• ]■I■� I A 'I, it Oil� ■■ l� i� ■■ I'E�I VALVE WATERFLOW INIFOLD iI ') JI'llE t �_ WATERFLOW7 MANIFO (DRAIN DETECTOR BODY VALVE DETECTOR BODY D CONNECTION) c (GRAIN BASIC ASSEMBLY WITH TEST AND DRAIN VALVE BASIC ASSEMBLY WITH TEST AND DRAIN VALVE CONNECTION) (2'(50MM)VERSION SHOWN)SEE TABLE 2. &PRESSURE RELIEF KIT (TEST AND DRAIN SHOWN IN'OFF"POSITION) (2"(50MM)VERSION SHOWN)SEE TABLE 2. 615Fco10 (TEST AND DRAIN SHOWN IN"OFF'POSITION) Fig. 1 Note:1114" Grooved end Test and Drain valves are available in various orifice size as Made To Order(MTO). • 2. GROOVED ENDS ASSEMBLIES(211(50MM),2-1/211(65MM),3180MM),4"(100MM),611(150MM),&81'(200MM)) B B D D • 3-WAY 3-WAY VALVE VALVE i STREET dQ STREET SAELBOW u ELBOW C ■lilutill 46t ■li1l1) aillpE e� PRESSURE PRESSURE a �1I I� PRESSURE luV,x� II II RELIEF GAUGE ,—.I MI: GAUGE .I 191�`i KIT A !t► o- i,'1' E q t► r `'lllll� E `• 1 "t'� (TAKE OUT) I __ .� (TAKE OUT) (1. . y WATERFLOWJ I BALL WATERFLOWJ , DETECTOR B 6 DIFOLD C VALVE DETECTOR MANIFOLD 1.;I (DRAIN BODY 11i CONNECTION) BALL I VALVE BASIC ASSEMBLY(3"(80MM)VERSION SHOWN) C----1 (DRAIN (SEE TABLE 1.) CONNECTION) BASIC ASSEMBLY WITH PRESSURE RELIEF KIT (3"(80MM)VERSION SHOWN)(SEE TABLE 1.) B B D PRESSURE D VALVE GAUGE 3-WAY II (' — VALVE l I 'If'� _ yii -..�:... j y• I. IiiiilloidLi-- n y ` ■1■i5 ■! 11TI Cr) (\1\ A. != PRESSURE • 111 E GAUGE E ,—� (TAKE OUT) ' I (TAKE OUT) I �� !� A I )) 111 • ' - 1 I I . I- A // WAETEC O R MANIFOLD WATERFLOW.. MANIFOLD DETECTOR BODY DETECTOR BODY C--I VALVE Ing (DRAIN I CONNECTION) C-1 \ VALVE BASIC ASSEMBLY WITH TEST AND DRAIN VALVE (DRAIN (4"(100MM)VERSION SHOWN)(SEE TABLE 2.) BASIC ASSEMBLY WITH TEST AND DRAIN VALVE CONNECTION) (TEST AND DRAIN SHOWN IN"OFF"POSITION] &PRESSURE RELIEF KIT (4"(100MM)VERSION SHOWN)(SEE TABLE 2.) (TEST AND DRAIN SHOWN IN'OM POSITION 611WWM Fig.2 Note:11/4" Grooved end Test and Drain valves are available in various orifice size as Made To Order(MTO). • 3. Table 1 Dimensions&Weights Basic Assembly Basic Assembly with Pressure Relief Kit Manifold A B C D E Weight A B C D E Weight Pipe Size ( ) (mm) ( ) ( ) (kg) ( ) ( ) ( ) ( ) (mm) ( g • in(mm) in mm in in mm in(mm) in mm lbsIn mm in mm in mm in mm in lbs k ) Threaded 11/2(40) 11 11'/2 3 73/4 81/4 8.3 13'/2 123/4 3 73/4 81/4 10.4 Ends (279) (29) (76) (197) (210) (3.8) (343) (324) (76) (197) (210) (4.7) (See Fig.1) 2(50) 11 121/4 3'/4 8 81/4 9.1 131/2 13'/2 31/4 8 81/4 11.2 (279) (311) (83) (203) (210) (4.1) (343) (343) (83) (203) (210) (5.1) 2(50) 123/4 16 51/4 8 13 10.7 163/4 173/4 5/4 8 13 13.3 (324) (406) (133) (203) (330) (4.9) (425) (451) (133) (203) (330) (6.0) 21/2 12314 161/2 5/2 81/4 13 12.9 163/4 181/4 51/2 8'/4 13 16.7 (65) (324) (419) (140) (210) (330) (5.9) (425) (464) (140) (210) (330) (7.6) Grooved 3(80) 123/4 17 53/4 81/2 13 17.6 163/4 183/4 53/4 872 13 18.3 Ends (324) (432) (146) (216) (330) (8.0) (425) (476) (146) (216) (330) (8.3) (See Fig. 2) 4(100) 121/2 19 61/4 9 13 21.3 163/4 19'/2 7 9 13 26.7 (318) (483) (159) (229) (330) (9.7) (425) (495) (168) (229) (330) (12) 6(150) (318) (508) (59) (254) (330) (12) (425) (521) (178) (254) (330) (14.4) 8(200) 121/2 22 4774 11 13 31.0 163/4 22'/2 8 11 13 36.5 (318) (559) (184) (280) (330) (14.1) (425) (572) (203) (280) (330) (16.6) Dimensions&Weights Table 2 Basic Assembly with Test and Drain Valve Basic Assembly with Test and Drain Valve&Pressure Relief Kit Manifold A B C D E Weight A B C D E Weight Pipe Size n in(mm) in(mm) in(mm) in(mm) in(mm) lbs(kg) in(mm) in(mm) in(mm) in(mm) in(mm) lbs(kg) in Threaded 11/2(40) 11 16 3 73/4 8114 10.0 143/4 16 3 73/4 8'/4 10.8 Ends (279) (406) (76) (197) (210) (4.5) (375) (406) (76) (197) (210) (4.9) • (See Fig.1) 2(50) 11 16'/2 31/4 8 81/4 10.8 143/4 161/2 31/4 8 83/4 11.6 (279) (419) (83) (203) (210) (4.9) (375) (419) (83) (203) (210) (5.3) 2(50) 123/4 181/2 5/4 8 13 10.7 151/4 181/2 51/4 8 13 13.3 (324) (470) (133) (203) (330) (4.9) (387) (470) (133) (203) (330) (6.0) 2'/z(65) 123/4 19 51/2 8'/4 13 12.9 15/4 19 51/2 81/4 13 16.1 (324) (475) (140) (210) (330) (5.9) (387) (475) (140) (210) (330) (7.3) Grooved 3(80) 123/4 193/4 53/4 8'/2 13 17.6 15/4 193/4 53/4 81/2 13 17.0 Ends (324) (502) (146) (216) (330) (8.0) (387) (502) (146) (216) (330) (7.7) (See Fig.2) 4(100) 14 23 63/4 9 13 25.8 181/4 23 63/4 9 13 26 (356) (584) (172) (229) (330) (11.6) (464) (584) (172) (229) (330) (11.8) 6(150) 14 251/2 8 10 13 30 1814 2572 8 10 13 31 (356) (648) (203) (254) (330) (13.6) (464) (648) (203) (254) (330) , (14.1) 8(200) (362) (686) (229) (280) (3 30) (16) (470) (686) (229) (280) (330) (16.5) • 4. • Basic Trim with Test and Drain Valve&Pressure Relief Kit Engineering Specification Commercial riser manifold assembly includes a cU- [Model CR Commercial Riser Assembly] shall be [UL Lus Listed pressure gauge, a 1/4" three-way valve, a Listed][ULC Listed] [Factory Mutual(FM)Approved]for hor- • Test and Drain Valve, and a dedicated waterflow de- izontal or vertical installation as a one-piece, fabricated as- tector containing two sets of SPDT(Form C)contacts, sembled unit. The [Model CR Commercial Riser Assembly] having an electrical rating of 10A @ 125/250 VAC/2.5 shall consist of a(choose one): A @ 24 VDC. See Table 3 for triggering flow rates. The • 11/2" (40 mm) cast, non-welded stainless steel body non-adjustable Pressure Relief Kit will maintain system with threaded end connections pressures below 175 psi(12.1 bar). The available test • 2" (50 mm) cast, non-welded, stainless steel body orifice size inside the Test and Drain Valve are with threaded end connections (Choose one): • 2" (50 mm)cast, non-welded, ductile iron body with • 3/8" (K-2 8)0) grooved end connections • 21/2" (65 mm) cast, non-welded, ductile iron body • 7/16" (K-4.2) with grooved end connections • 1/2" (K-5.6) • 3" (80 mm) cast, non-welded, ductile iron body with • t7/32" (K-8.0) grooved end connections • 5/8" (K 11 2)t3> • 4" (100 mm)cast, non-welded, ductile iron body with grooved end connections • 3/4" (K-14.0)(3) • 6" (150 mm)cast, non-welded, ductile iron body with • 15/16" (K-16.8)(2)(3) grooved end connections • 15/64" (K-22.4)(2)(3) • 8" (200 mm)cast, non-welded, ductile iron body with grooved end connections • 19/64" (K-25.2)(2)(3) having all brass and galvanized trim. The manifold pip- (1)Not available for 4",6"and 8"risers. ing shall clearly identify the manifold's pipe size, flow di- (2)Not available for 1V2"to 3"risers. rection, UL Listing/ULC Listing/FM Approval, drain, and (3)Not available for 1'h"to 2"threaded&2"grooved risers. gauge outlets. A built-in drain port shall be available to Installation permit hydrostatic testing without draining the system. 1. Attach the pressure gauge as shown in Figures 1-4. This drain port shall be sized per the following: 2. Install the manifold with the flow arrow pointing • 1"(25mm)for 11/2"(40mm) and 2"(50mm) sizes. • towards the SYSTEM side using threaded fittings • 11/4"(32 mm)for 21/2"(65mm), and 3"(80mm) sizes. or grooved pipe couplings. • 2"(50mm) for 4"(10omm), 6"(150mm) and 8"(200mm) 3. Connect the appropriately sized drain line. sizes. 4. Ensure that the drain valve is in the CLOSED posi- Take-out dimensions shall be the same for the 11/2"(40mm) tion. and 2"(50mm)threaded sizes. End-to-end dimensions shall 5. Place the sprinkler system in service. be the same for the 2" (50mm)through 3" (80mm)grooved 6. Installation must comply with NFPA 13, Section sizes.Assembly shall have a working pressure rating of[250 8.16.4.2 psi (17.2 bar) (for 11/2" (40mm) and 2" (50mm) threaded manifold assemblies)] [300 psi (20.7 bar) (for 2" through 3" Caution: grooved manifold assemblies)]. Automatic sprinkler systems having non-fire protection End-to-end dimensions shall be the same for the 4" connection (permitting continual water flow) require dielec- (100mm) through 8" (200mm) grooved sizes. Assembly tric fittings, according to NFPA 13 sect. 4-6,when dissimilar shall have a working pressure rating of [300 psi (20.7 bar) metal piping materials are joined. (for 4" (100mm) through 8" (200mm) grooved manifold as- Note: semblies)]. Use a non-hardening pipe joint compound, or teflon tape. Table 3 Follow the manufacturer's instructions when using grooved pipe couplings. Manifold Sizes Triggering Flow Rate-GPM(LPM) 1 Y"(40mm),2"(50mm)'Listings and Approvals 21/2'(65mm)&3"(80mm) 4(15)to 10(38) 1. Listed by Underwriters' Laboratories Inc. and ULC 4"(100mm),6"(150mm), Listed. &8"(200mm) 4(15)to 10(38) 2. Factory Mutual Approved. 3. NYC MEA 258-93-E • 5. Ordering Information: Model CR Commercial Riser Assembly Part Number Code Key 1.5NT B 0 1.5MT T28(K-2.8)(1) 1 • 2NT T42(K-4.2) 2 2MT T56(K-5.6) 3 2G T80(K-8.0) 2.5G _ T112(K-11.2)(3) 0=Assembly without Pressure Relief Kit 3G T740(K-t 4.0)(3) - Water Detector-cULus&FM 4G T168(K-16.8)(2)(3) 1 =Assembly with Pressure Relief Kit 6G T224(K-22.4)()(3) Water Detector-cULus&FM 8G T252(K-25.2)(2)(3) 2=Assembly without Pressure Relief Kit Water Detector-ULC 1.5NT= 1'/2"(40 mm) B=Basic Assembly 3=Assembly with Pressure Relief Kit NPT Threaded Ends Assembly T28=W/K-2.8 Test&Drain Valve Water Detector-ULC 1.5MT= 1'/e"(40 mm) T42=W/K-4.2 Test&Drain Valve Metric Threaded Ends Assembly 1 T56=W/K-5.6 Test&Drain Valve 2NT=2"(50mm) NPT Threaded Ends Assembly T80=W I K-8.0 Test&Drain Valve 2MT=2"(50 mm) T112=W/K-11.2 Test&Drain Valve(3) Metric Threaded Ends Assembly T140=W/K-14.0 Test&Drain Valve(3) 2G=2"(50 mm) T168=W/K-16.8 Test&Drain Valvei21(3) Grooved Ends Assembly 2.5G=21/2"(65 mm) T224=W/K-22.4 Test&Drain Valve121131 Grooved Ends Assembly T252=W/K-25.2 Test&Drain Valve12l(3) 3G=3"(80 mm) Grooved Ends Assembly 1')Not available for 4",6"and 8"risers. 4G=4" 100 mm (2)Not available for 1'/2"to 3"risers. Grooved Ends Assembly (3)Not available for 11/2"to 2"threaded &2"grooved risers. 6 d E" • Grooved Endss Arse Assembly • For Grooved end Test and Drain valves 8G=8"(200 mm) (See note 3) Grooved Ends Assembly Example#1: 1.5NT—B—1 (11/2" (40mm) Model CR Commercial Riser Assembly with NPT female inlet and outlet threads, basic trim with installed Pressure Relief Kit). Example#2: 3G—T56—0 (3"(80mm)Model CR Commercial Riser Assembly with grooved ends, basic trim with Test and Drain Valve having a 5.6 K factor, without a Pressure Relief Kit) Example#3: 6G—T80—0 (6"(150mm) Model CR Commercial Riser Assembly with grooved ends, basic trim with Test and Drain Valve having a 8.0 K factor, without a Pressure Relief Kit) Notes: 1. All Model CR Commercial Riser Assemblies come with a 300 psi (20.7 bar) UL Listed and FM Approved pressure gauge for 175 psi (12.1 bar) applications. If the Model CR Commercial Riser Assembly is to be installed in a 300 psi (20.7 bar)application, please purchase a 600 psi (41.4 bar)(P/N 98248005) pressure gauge.This gauge may or may not be UL Listed and/or FM Approved at the time of purchase. 2. If required, Pressure Relief Kits may also be installed in the field. Please contact Reliable's Customer Service Department for details. 3. 11/4"and 2"Grooved end Test and Drain valves are available in various orifice size K factor as MTO. Please contact Reliable Service Department for details. The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. • Manufactured by Reliable Automatic Sprinkler Co.,Inc. ' Recycled emiabidPaper (800)431-1588 Sales Offices (800)848-6051 Sales Fax (914)829-2042 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address E.G.Printed in U.S.A.11/16 P/N 9999970349 Worldwide www.tyco-fire.com 0 iii L�CEt Contacts Model DPV-1 Dry Pipe Valve External Resetting General Description The TYCO Model DPV-1 Dry Pipe ; Valves are differential valves used to automatically control the flow of water into dry pipe fire protection sprinkler r systems upon operation of one or more i .. automatic sprinklers. The DPV-1 also provides for actuation of fire alarms ..- upon system operation. The Model s� DPV-1 features are as follows: ' • External reset. 6 4 • 250 psi(17,2 bar)pressure rating. _ • Unique offset single clapper design enabling a simple compact valve to minimize installation labor. • �_ • Ductile iron construction to ensure , a lightweight valve to minimize ship- ping cost. • A variety of inlet and outlet Available Sizes and End Connections connections. • Compact, Pre-Trimmed, and Semi- Nominal Valve Size Assembled, easy to operate valve End Connection 2-1/2 in. 3 in. 4 in. 6 in. trim. (DN65) (DN80) (DN100) (DN150) • Simple reset procedure through the Flange x Flange N/A N/A • • elimination of priming water. Flange x Groove N/A N/A • Dry pipe sprinkler systems are used Groove x Groove • • in unheated warehouses, parking garages, store windows, attic •=Available spaces, loading docks, and other N/A=Not Available areas exposed to freezing tempera- tures, where water filled pipe cannot applicable standards of the National Dry Pipe Valve be utilized. When set for service, the Fire Protection Association,in addition The TYCO Model DPV-1 Dry Pipe dry pipe sprinkler system is pressur- to the standards of any other authori- Valves shall be installed in the verti- ized with air(or nitrogen). The loss of ties having jurisdiction.Failure to do so cal orientation only (supply at bottom pressure through an operated auto- may impair the performance of these flowing upward)and are rated for use at matic sprinkler in response to heat devices. a maximum service pressure of 250 psi from a fire permits the DPV-1 Dry The owner is responsible for main- (17,2 bar). Valve and trim dimensions Pipe Valve to open and allow a flow of taining their fire protection system are shown in Figure 6. water into the sprinkler system piping. and devices in proper operating con- Flanged connections are available and Table B establishes the minimum dition. Contact the installing contrac- drilled per ANSI,ISO,AS,and JIS spec- required system air pressure that tor or product manufacturer with any ifications (Ref. Table A). The grooved includes a safety factor to help prevent questions. outlet connections, as applicable, are false operations that might occur due cut in accordance with standard groove to water supply fluctuations. Technical Data specifications for steel pipe. They are • NOTICE suitable for use with grooved end pipe Approvals couplings that are listed or approved The Model DPV-1 Dry Pipe Valves UL and C-UL Listed for fire protection system service. described herein must be installed FM Approved Available combinations of inlet and and maintained in compliance with NYC Approved outlet connections are described in this document, as well as with the Page 1 of 20 MAY 2018 TFP1O2O TFP1020 Page 2 of 20 NO. DESCRIPTION QTY. REF. • 1 Valve Body 1 NR 2 Air and Water Seat 1 NR 3 Handhole Cover...1 NR 4 Handhole Cover • 11 Gasket 1 (b) 5 1/2-13UNCx1"Hex Head Cap Screw: _ : 2-1/2&3Inch ' F 12 Valves 5 CH / 6 4 Inch Valve 6 CH ,/ 6 Clapper 1 (a) l 13 7 Clapper Facing... .1 (a)or(b) "if =1 7 CLAPPER _ RESET 8 Clapper Facing 14 PLUNGER Retaining Plate....1 (a) �% ASSEMBLY c)-------14 9 2-1/2 and 3 Inch Valves: - �J 8 ,p, 1/4"x 3/8'Long 15, 18 #10-32 Shoulder 1 9 ---o� Screw 5 (a) _ -------16 4 Inch Valve: 1/4-20 UNC x 1/2" Socket Head Cap 17 Screw 7 (a) 10 Clapper Hinge Pin 1 (a) 11 Reset Knob 1 (c)a or(d) C 12 Reset Spring 1 (c) 13 Reset Bushing ....1 (c) 14 Reset Bushing `(� ` 0-Ring. 1 (b),(c)or(e) 15 Reset Plunger TriReset 1 (b)or(c) • ' 16 Reset Plunger 1 (c) jil) 17 Reset Latch I - Subassembly 1 (c) %4418 Dow Corning FS3452 Flourosilicone I Grease,1.5 g 1 (b)or(c) I4 NR:Not Replaceable 464)6CW---- 3CH:Common Hardware 2to \ REPLACEMENT PARTS 411111 ®� i >tr, 0 NO.DESCRIPTION P/N ` / 0 - ,0 (a) Clapper Assembly Includes Items 6-10: 1 fo 0 2-1/2&3 Inch Valves.. 92-310-2-203 I . 4 Inch Valve 92-310-2-403 ` ,r ,,J'J (b) Repair Parts Kit 0 Includes Items 10 # //ilre 5 4,7,14,15,&18: 2-1/2&3 Inch Valves.. 92-310-1-204 4 Inch Valve 92-310-1-404 (c) Reset Plunger Parts Kit Includes Items 11-18.. 92-310-1-405 (d) Reset Knob,Item 11... 92-310-1-406 (e) Reset Bushing 0-Ring,Item 14 92-310-1-407 FIGURE 1 -PART 1 OF 2 MODEL DPV-1 DRY PIPE VALVE 2-1/2, 3,AND 4 INCH(DN65, DN80, DN100)ASSEMBLIES • TFP1 020 Page 3 of 20 • NO.DESCRIPTION QTY. REP.PART NO. DESCRIPTION QTY REP.PART NO. DESCRIPTION QTY. REP.PART 1 Valve Body 1 NR 5 Socket Head Cap 8 Hex Head Cap Screw 2 Air and Water Screw 5/8-11 UNC x 1'...6 CH Seat 1 NR 3/8-16 UNC x 1"...8 NR 9 Clapper 1 (a) 3 Water Seal 6 Handhole Cover...1 NR 10 Clapper Facing....1 (a)or(b) 0-Ring 1 NR 7 Handhole Cover 11 Clapper Facing 4 Air Seal 0-Ring....1 NR Gasket 1 (b) Retaining Plate....1 (a) 12 Socket Head Cap 'i Screw 1/4-20 UNC x 1/2.:.9 (a) 14 13 Clapper Hinge Pin..1 (a) 14 Reset Knob 1 (c)or(d) 15 15 Reset Spring 1 (c) 16 Reset Bushing .... 1 c 17 Reset Bushing C> 16 0-Ring 1 (b),(c)or(e) ��> ' , 10 CLAPPER `/i 18 Reset Plunger / RESET 0-Ring. 1 (b)or(c) c)iii\ss1/4., a ASSEMBLY 18,721 7 PLUNGER 19 Reset Plunger 1 (c) t‘ - 11 Cr--- 1 PARTS 20 Reset Latch 8,21 Subassembly 1 (c) o � 12 �-0 21 Dow Corning FS3452 - F Grease, licone C 19 Grease,1.5 g 1 (b)or(c) CD C) NR:Not Replaceable 20 CH:Common Hardware O 0 i REPLACEMENT PARTS ° NO. DESCRIPTION P/N (a) Clapper Assembly / Includes Items 9-13... 92-310-2-603 (b) Repair Parts Kit 2 Includes Items 7, 10,17,18,21 92-310-1-604 I "11\' �\ (c) Reset Plunger Parts Kit \\\`\ Includes Items 14-21 .. 92-310-1-405 �� 0)C) (d) Reset Knob,Item 14. .. 92-310-1-406 4 _ �' (e) Reset Bushing Ioli 0-Ring,Item 17 92-310-1-407 tird 4 1 it A %to r (0000 0 e 13 **It.� (0 0 / ` \ , 0 i ow 8 0 10 • FIGURE 1 -PART 2 OF2 MODEL DPV-1 DRY PIPE VALVE 6 INCH(DN150)ASSEMBLY TFP1020 Page 4 of 20 Flange Drilling Specification • Nominal Dimensions in Inches and(mm) Dim.A Nominal Bolt Circle Valve ANSI B16.11 ISO 7005-2 JIS B 2210 AS 2129 Diameter Size (Class 125) (PN16)2 (10K) (Table E) ®- 6D Dim. Dim. Qty. Dim. Dim. Qty. Dim. Dim. Qty. Dim. Dim. Qty. m Dim.B A B N A B N A B N A B N ( �� I a; Dim. Hole 4 in. 7.50 0.75 s 7.09 0.75 8 6.89 0.59 8 7.00 0.71 8 © �/ Diameter (DN100) (190,5) (19,0) (180,0) (19,0) (175,0) (15,0) (178,0) (18,0) e_� 6 in. 9.50 0.88 9.45 0.91 9.45 0.75 9.25 0.87 Qty.N (DN150) (241,3) (22,2) 8 (240,0) (23,0) 8 (240,0) (19,0) 8 (235,0) (22,0) 8 Number of Bolt Holes 1. Drilling same as ANSI B16.5(Class 150)and ANSI B16.42(Class 150). 2. Drilling same as BS 4504 Section 3.2(PN16)and DIN 2532(PN16). TABLE A SELECTION OF FLANGE DRILLING SPECIFICATIONS the Ordering Procedure section and in • Connections For Optional Quick 4 in.(DN100)GxG 57 lb(26 kg) the Available End Connection and Sizes Opening Device(Accelerator) 4 in.(DN100)FxG 67 lb(31 kg) table on page 1. Pre-trimmed valve assemblies also 4 in.(DN100)FxF 77 lb(36 kg) Trim port connections of valves having include the following equipment: flanges drilled to ANSI,AS,or JIS spec- • 6 in.(DN150)GxG 95 lb(44 kg) ifications are NPT threaded per ANSI Model BFV-300 butterfly valve 6 in.(DN150)FxG 108 lb(50 kg) Standard B1.20.1. Trim port connec- • Figure 577 grooved coupling 6 in.(DN150)FxF 121 lb(56 kg) tions of valves having flanges drilled • PS10-2 waterflow alarm switch to ISO are available either threaded Air Supply per ISO 7-1 or NPT threaded per ANSI • PS40-2 low air pressure alarm switch Table B shows the system air pres- Standard B1.20.1. Valves with NPT Order the above equipment sepa sure requirements as a function of the threaded ports will readily accept the rately when ordering trim packages water supply pressure.The air(or nitro- trim arrangements shown in Parts 2 separately. gen) pressure in the sprinkler system and 3 of Figures 3,4,and 5. is recommended to be automatically are Note: When the system pressure is maintained by using one of the follow- Model DPV-1 Valve assemblies greater than 175 psi(12,1 bar),provision ing pressure maintenance devices, as shown in Figure 1.The Body and Hand-are • hole Cover are ductile iron.The Hand- shall be made replace the standard appropriate: order300 psi 20,7bar Water Pressure hole Cover Gasket is neoprene, and gauge with •a separately ordered 600 • Model AMD-1 Air Maintenance the Clapper Facing is EPDM. The Air/ psi(41,4 bar)Water Pressure Gauge. Device(pressure reducing type) Water Seat Ring is brass, the Clapper is bronze or aluminum bronze,and both Weights • Model AMD-2 Air Maintenance the Clapper Retaining Plate and Latch The following are the nominal weights Device(compressor control type) are bronze.The Hinge Pin is aluminum for Pre-Trimmed Valve Assemblies, • Model AMD-3 Nitrogen Maintenance bronze,and the fasteners for the Hand- Semi-Assembled Trim, and DPV-1 Device(high pressure reducing type) hole Cover are carbon steel. Valves without trim. The Pressure Relief Valve provided with Valve Trim Pre-Trimmed DPV-1 Valve the valve trim is factory set to relieve Installation dimensions are provided Assemblies: at a pressure of approximately 45 psi in Figure 6, and Valve Trim and Pre- P_1/2 in.(DN65)GxG 87 lb(40 kg) (3,1 bar).If the normal system air pres- Trimmed Valve Assemblies are shown sure is less than or exceeds 40 psi(2,8 in Figures 3,4,and 5. 3 in.(DN80)GxG 90 lb(42 kg) bar), then the pressure Relief Valve The valve trim,ordered separately or as 4 in.(DN100)GxG 121 lb(56 kg) must be reset to relieve at a pressure that is in accordance with the authority a pre-trimmed valve assembly, forms 4 in.(DN100)FxG 135 lb(64 kg) having jurisdiction. a part of the laboratory listings and approvals of the DPV-1 Valve and is 4 in.(DN100)FxF 145 lb(69 kg) Quick Opening Device necessary for the proper operation of 6 in.(DN150)GxG 175 lb(81 kg) The Model DPV-1 Dry Pipe Valve may the DPV-1 Valve. optionally be equipped with an elec- Trim packages or pre-trimmed valve 6 in.(DN150)FxG 195 lb(90 kg) tronic or mechanical dry pipe valve assemblies include the following 6 in.(DN150)FxF 208 lb(96 kg) accelerator. Select the VIZOR equipment: Standard Galvanized Elec- tronic Dry Pipe Valve Accelerator (4 and 6 in. sizes only) described in • Water Supply Pressure Gauge Semi-Assembled DPV-1 Trim: Technical Data Sheet TFP1105 or the • System Air Pressure Gauge 2-1/2 in.(DN65) 23 lb(11 kg) Model ACC-1 Mechanical Dry Pipe Valve Accelerator (2-1/2 through 6 in. • Air Supply Connections 3 in.(DN80) 23 lb(11 kg) sizes) described in Technical Data • Main Drain Valve 4 in.(DN100) 30 lb(14 kg) Sheet TFP1112. • Low Body Drain Valve 6 in.(DN150) 30 lb(14 kg) The VIZOR or the ACC-1 is used to • reduce the time to valve actuation fol- • Alarm Test Valve DPV-1 Valve(Without Trim): lowing the operation of one or more • Automatic Drain Valve 2-1/2 in.(DN65)GxG 37 lb(17 kg) automatic sprinklers. In some cases the use of a quick opening device • DripFunnel 3 in.(DN80)GxG 38 lb(18 kg) such as the VIZOR or the ACC-1 may TFP1020 Page 5 of 20 • Maximum System Air FLOW RATE IN LITRES PER MINUTE(LPM) Water Supply Pressure (1 GPM=3.785 LPM) Pressure Range 500 700 1000 2000 3000 5000 10000 psi psi _ 9.0 I I I I I I I I IIIII I I 20 10 a 7.0 0,60 in 80 20-28 U 1111 II ,IP]il II'I10,40 z 5.0 �100 25-33 w4.0 :: o f'I1II II/� ' IIIIIIIf/1IIiI 0,30 145 35-43 o 3.0 O 0,20CD : , I1pp,1111pir1uIIIillIan165 40-48 ....a 2.0 mi:' ' ..IIIII ) ..:185 45-53 �') �I,lum ���1 :::: r7 . .:....�... ..... O Q o ...... 205 50-58 u) :: ar •.... no 'mass •,• ...:::: 0,10 CC m 225 55-63 Z ■ u: roy , . 112111 OO r' '..•" O Lo D . rm Q 17.uu :`.E 1..... 0,08 w w 250 60-68 ci_ 1.0 0: :�1 US !:I!n Q' ; m::�oo j o Z ..... (,�.9::2 .'..:I: . :::::::: 0,06 cn o TABLES ... ? Ai a 0�nu. .."--.. 0,05 w II SYSTEM AIR PRESSURE a 0.7 :�ry i��C. ru'us ,•,, �,•• m_ REQUIREMENTS o 0.5 ____:•ry m i����iiilll��lliiill 0,04 a d be required to meet there requirements of 0.4 r 1. i niiiririiiili 0,03iiiiii the National Fire Protection Association 0g i III o to meet water delivery times. w �' 0,02 Z if. pppjrJ IliillilllllOperation z0.2 • 1 IIIIIIIIIIII 0,01 The TYCO Model DPV-1 Dry Pipe Valve o I I is a differential type valve that utilizes a z 0.1 substantially lower system(air or nitro- 100 200 300 500 700 1000 2000 3000 gen) pressure than the supply (water) FLOW RATE IN GALLONS PER MINUTE(GPM) I • pressure, to maintain the set position shown in Figure 2A. The differential The approximate friction losses,based on the Hazen and Williams formula and expressed in equivalent length of Schedule 40 pipe with C=100 and flowing at typical flow rates,are as follows: nature of the DPV-1 is based on the 2-1/2 In.valve at 250 GPM flow=2.2 ft 4 in.valve at 600 GPM flow=8.9 ft area difference between the air seat 3 in.valve at 350 GPM flow=4.9 ft 6 in.valve at 1500 GPM flow=22.0 ft and the water seat in combination with GRAPH A the ratio of the radial difference from MODEL DPV-1 DRY PIPE VALVES the Hinge Pin to the center of the Water NOMINAL PRESSURE LOSS VS. FLOW Seat and the Hinge Pin to the center of the Air Seat.The difference is such that the top of the Clapper would only be 10 port is also sufficient to close the oth- 1 psi (0,07 bar)of system air pressure psi (0,7 bar). This pressure would be erwise normally open Automatic Drain can hold approximately 5.5 psi (0,38 insufficient to hold the Clapper Assem- Valve in the valve trim. bar)of water supply pressure. bly closed against a water supply pres- Table B establishes the minimum sure of 100 psi (6,9 bar). It is for this After a valve actuation and upon sub- required system air pressure that reason that the plunger of the Auto- controSequent closing of a system main includes a safety factor to help prevent matic Drain Valve must be depressed Clapper valve to stop water flow, theas false operations that occur due to water during several of the resetting steps, showninAssembly will latch open of supply fluctuations. as well as during inspections, making shown Figure p 3D.m Latching open drain- certain - that the Automatic Drain Valve the DPV-1 will permit complete The Intermediate Chamber of the is open. Fins of the system (including any loose DPV-1 is formed by the area between scale)through the main drain port. the Air Seat and Water Seat as shown in When one or more automatic sprin- During the valve resetting procedure Figure 2B. The Intermediate Chamber klers operate in response to a fire, and after the system is completely normally remains at atmospheric pres- air pressure within the system piping drained,the external reset knob can be sure through the Alarm Port connection is relieved through the open sprin- easily depressed to externally unlatch and the valve trim to the normally open klers. When the air pressure is suf- the Clapper Assembly, as shown Automatic Drain Valve (Fig. 3, 4, or ficiently reduced, the water pressure in Figure 2E. As such, the Clapper 5). Having the Intermediate Chamber, overcomes the differential holding Assembly is returned to its normal set Figure 2B,open to atmosphere is criti- the Clapper Assembly closed and the position to facilitate setting of the dry cal to the DPV-1 Valve remaining set, Clapper Assembly swings clear of the pipe sprinkler system,without having to otherwise the full resulting pressure of water seat, as shown in Figure 2C, remove the Handhole Cover. the system air pressure on top of the This action permits water flow into the Clapper Assembly cannot be realized. system piping and subsequently to be For example, and assuming a water discharged from any open sprinklers. • supply pressure of 100 psi (6,9 bar), if Also,with the Clapper Assembly open, the intermediate chamber is pressur- the system air pressure is 25 psi (1,7 ized and water flows through the alarm bar) and there was 15 psi (1,0 bar) port (Ref. Figure 2B)at the rear of the pressure trapped in the Intermediate DPV-1 Valve to actuate system water Chamber,the resulting pressure across flow alarms. The flow from the alarm TFP102O Page 6 of 20 Installation be equipped with a Dry Pipe Valve however, it must be reset to relieve • Accelerator, refer to the Technical at a pressure which is in accordance General Instructions Data Sheet TFP1105 for the VIZOR with the requirements of the author- Proper operation of the Model DPV-1 Electronic Dry Pipe Valve Accel- ity having jurisdiction. Dry Pipe Valve depends upon its trim erator or TFP1112 for the Model To reset the Pressure Relief Valve, being installed in accordance with the ACC-1 Mechanical Dry Pipe Valve first loosen the jam nut and then Accelerator. adjust the capaccordingly instructions given in this Technical Data 1 9 Y — Sheet. Failure to follow the appropriate • Care must be taken to make sure that clockwise for a higher pressure trim diagram may prevent the DPV-1 check valves,strainers,globe valves, setting or counter-clockwise for a Valve from functioning properly, as etc.are installed with the flow arrows lower pressure setting.After veri- well as void listings,approvals,and the in the proper direction. fying the desired pressure setting, manufacturer warranties. tighten the jam nut. • Drain tubing to the drip funnel must • Installation of an Air Maintenance Failure to latch open the Clapper be installed with smooth bends that Device, as described in the Techni Assembly prior to a system hydro- will not restrict flow. cal Data Section, is recommended. static test may result in damage to the • The main drain and drip funnel drain 1 Clapper Assembly. • An Inspector's Test Connection as may be interconnected provided a required ByNFPA 13 must be pro The DPV-1 Valve must be installed in a check valve is located at least 12 in. q vided on the system piping at the readily visible and accessible location. (300 mm)below the drip funnel.The most remote location from the Model The DPV-1 Valve and associated trim Low Body Drain Valve(Figure 3,4,or DPV-1 Valve. must be maintained ate minimum tem- 5) may be piped so as to discharge perature of 40°F(4°C). into the Drip Funnel or to a separate • Conduit and electrical connections drain. are to be made in accordance with Heat tracing of the DPV-1 Valve or its the requirements of the author- associated trim is not permitted. Heat • Suitable provision must be made ity having jurisdiction and/or the tracing can result in the formation of for disposal of drain water. Drainage National Electric Code. hardened mineral deposits that are water must be directed such that it capable of preventing proper operation. will not cause accidental damage to • Before a system hydrostatic test is property or danger to persons. performed in accordance with NFPA The Model DPV-1 Dry Pipe Valve is to . Unused pressure alarm switch and/ 13 system acceptance test require- be installed in accordance with the fol- or water motor alarm connections ments, the Clapper Assembly is to lowing criteria: must be plugged. be manually latched open (Ref. Fig- • All nipples,fittings,and devices must ure 2D); the Automatic Drain Valve • be clean and free of scale and burrs • The Pressure Relief Valve provided (Figure 3,4,or 5)is to be temporarily before installation. Use pipe thread with the Valve Trim is factory set to replaced with a 1/2 in.NPT plug,the sealant sparingly on male pipe relieve at a pressure of approximately 3/32 in. Vent Fitting (Item 13, Figure threads only. 45 psi (3,1 bar), which can typically 3; Item 15, Figure 4; or Item 15, Fig- be used for a maximum normal sys- ure 5) is to be temporarily replaced • The DPV-1 Valve must be trimmed tem air pressure of 40 psi (2,8 bar). with a 1/4 in. NPT plug, and the in accordance with Figures 3, 4, or The Pressure Relief Valve may be Handhole Cover Bolts are to be tight- 5, as applicable. If the DPV-1 is to reset to a lower or higher pressure; ened using a cross-draw sequence. 0 TFP1O2O Page 7 of 20 • Valve Setting Step 5.As necessary,replace all sprin- DPV-1 Valve. If air is discharging, refer klers that have operated. Replacement to the Care and Maintenance section sprinklers must be of the same type under Automatic Drain Valve Inspection Procedure and temperature rating as those which to determine/correct the cause of the have operated. Steps 1 through 11 are to be performedleakage problem. when initially setting the Model DPV-1 Step 10. Partially open the Main Dry Pipe Valve;after an operational test NOTICE Control Valve. Slowly close the Main of the fire protection system; or, after In order to prevent the possibility of Drain Valve as soon as water dis- system operation due to a fire. a subsequent operation of an over- charges from the drain connection. NOTES:If the DPV-1 is equipped with heated solder type sprinkler,any solder Depress the plunger on the Automatic a Dry Pipe Valve Accelerator, refer to tpe sprinklers which were possibly Drain Valve to make sure that it is open its resetting instructions before reset- exposeda temp greater than and that there is no water discharging. ting the DPV-1.Refer to TFP1105 for the their maximum rated ambient must be The absence of water discharging from VIZOR or TFP1112 for the ACC-1. replaced. the Automatic Drain Valve is an indica- Based on the instructions provided, Step 6. Push down on the Reset Knob tion of a properly set water seat within reset the Accelerator at the appropriate (Figure 2E)to allow the Clapper Assem- the DPV-1 Valve. If water is discharg- time during the resetting of the DPV-1. bly to re-seat. ing, refer to the Care and Maintenance Step7. Pressurize the system with air section under the Automatic Drain Unless otherwise noted,refer to Figure y Valve Inspection to determine/correct 3, 4, or 5 to identify functional trim (or nitrogen) to 10 psi (0,7 bar), and the cause of the leakage problem. components. then individually open all auxiliary drain valves in the system piping to drain If there are no leaks,the DPV-1 Valve is Step 1. Close the Main Control Valve, any remaining water in trapped sec- ready to be placed in service and the and close the Air Supply Control Valve. tions. Close each drain valve as soon Main Control Valve must then be fully If the DPV-1 is equipped with a Dry as water ceases to discharge. opened. Pipe Valve Accelerator,remove the Dry Pipe Valve Accelerator from service in Also partially open the Low Body Drain Note: After setting a fire protection accordance with its Technical Data Valve to assure that the riser is corn- system, notify the proper authorities Sheet(Refer to TFP1105 for the VIZOR pletely drained. Close the Low Body and advise those responsible formoni- or TFP1112 for the ACC-1). Drain Valve as soon as water ceases toring proprietary and/or central station to discharge. alarms. Step 2.Open the Main Drain Valve and all auxiliary drains in the system.Close Step 8. Refer to Table B and then Step 11. Once a week after a valve is • the auxiliary drain valves after water ceases to discharge. Leave the Main restore the system to the normal reset following an operational test or system air pressure as necessary to system operation,the Low Body Drain Drain Valve open. hold the DPV-1 Valve closed. Valve (and any low point drain valves) Step9. Depress the should be partially opened (and then Step 3. Depress the plunger of the P plunger on the subsequently closed) to relieve drain- Automatic Drain Valve to verify that it is Automatic Drain Valve to make sure back water. Continue this procedure open and that the DPV-1 Valve is corn- it is open and that there is no air until drain-back water is no longer pletely drained. discharging. 9 present. Step 4. Open the Optional Alarm The absence of air discharging from Control Valve, as applicable, if it was the Automatic Drain Valve is an indica- closed to silence local alarms. tion of a properly set air seat within the • TFP1020 Page 8 of 20 AIR PRESSURE WATERFLOW • TO SYSTEM TO SYSTEM ICLAPPER CLAPPER �. 1" NPT ASSEMBLY ASSEMBLY AIR SUPPLY 1444\ IN SET FULLY OPEN PORT POSITION AM 01 �i \ INI HP � . . CLAPPER LATCH �I; PIVOTS TO ALLOW �'�I" 1/2"NPT •i . CLAPPER ASSEMBLY =2"� WATER TO FULLY OPEN i SUPPLY rJ%////////////////�i1//A IQ, i PRESSURE (., ���t��``` 3/4"NPT ALARM inl�:iJ &ALARM njx. 4 i'1 PORTOPENTE0 11 / i .4-. TEST PORT - wig ATMOSPHERE '1n�Ip ALARM PORT 02 ��� I 03 ^^I In WATERFLOW CLAPPER rTO ALARM ASSEMBLY FROM FROM WATER SUPPLY � , AIR WATER SUPPLY SEAT FIGURE 2A %///// ...,, FIGURE 2C SET POSITION WATER �� 1 OPERATED POSITION y///� SEAT ^^^ 03 ALARM PORT DRAIN FROM DRAIN FROM SYSTEM SYSTEM VALVE INTERMEDIATE COMPLETE I WATERWAY FIGURE 2B CHAMBER PUSH HERE TO RESET • SET POSITION cALVE INTERMEDIATE RESET CHAMBER KNOB CLAPPER ASSEMBLY = i LATCHED = RESET OPEN 'Z1 ASSEMBLY CLAPPER ��� //N///4,"�"� PIVOTS TO � r CLAPPER UNLATCH J ! cj CLAPPER 1` mk / ASSEMBLY Inh •� i r04 ' MAIN DRAIN PORT: liii 3/4"NPT ol 05 1-1/4"NPT*(2-1/2 INCH ^�� ASSEMCLAPPBLY LOW BODY ��� &3 INCH VALVES) DRAIN 2"NPT(4 INCH VALVE) i r RESEATED *PORT i r WATER SUPPLY DN40 FOR VALVES WITH WATER SUPPLY SHUT OFF ISO THREADED PORTS SHUT OFF FIGURE 2D FIGURE 2E DRAIN POSITION RESET POSITION FIGURE 2-PART 1 OF 2 MODEL DPV-1 DRY PIPE VALVES 2-1/2,3,AND 4 INCH(DN65, DN80,AND DN100) SET AND OPEN POSITIONS 0 TFP1 020 Page 9 of 20 • AIR PRESSURE WATERFLOW TO SYSTEM TO SYSTEM lit CLAPPER ASSEMBLY t FULLY OPEN 1" NPT CLAPPER LATCH `prH AIR SUPPLY PIVOTS TO ALLOW �I PORT CLAPPER ASSEMBLY � .\ _ m TO FULLY OPEN . . '�' a \ ails ,, 3/4" NPT ALARM CLAPPE "� 03 PORT OPEN TO ,— �;7 ASSEMBL7Y ATMOSPHERE \`\\ INSET . i%�%/U/////////�/�//���/�i. 1$ I POSITION _ ____ �\�� 1/2" NPT `Y_S '� �� WATER SUPPLY '�" �' '%/�//i_I%7� 02 PRESSURE Vil ������%A &ALARM __:, r� Illik TEST PORT ��11ARMPORT t ��^ WATERFLOW CLAPPER TO ALARM ASSEMBLY AIR FROM FROM WATER SUPPLY - mi EAT WATER SUPPLY FIGURE 2A '•N. '— ALARM im FIGURE 2C ` SET POSITION WATER iA. '4 PORT OPERATED POSITION SEAT 4ESIII I I 03 DRAIN FROM • DRAIN FROM , FIGURE 28 SYSTEM SYSTEM INTERMEDIATE VALVE COMPLETE I CHAMBER WATERWAY t PUSH HERE SET POSITION TO RESET INTERMEDIATE • VALVE CLAPPER CHAMBER ASSEMBLY i RESET LATCHED KNOB OPEN RESET , ASSEMBLY 3/4"NPT ���41p,., LOW BODY ///���Q��.`",� CLAPPER _ � DRAIN ill —4.4�� 4'. LATCH i t4. PORT PIVOTS TO ������������ UNLATCH �/ �1 04 �" CLAPPER /!.J/% �� .: ASSEMBLY 2" NPT 0 .•MAIN DRAIN •' CPPER 0DRNMIraimYASSEMBLY 5 RESEATED WATER SUPPLY WATER SUPPLY SHUT OFF SHUT OFF FIGURE 2D FIGURE 2E DRAIN POSITION RESET POSITION FIGURE 2-PART 2 OF 2 MODEL DPV-1 DRY PIPE VALVES III 6 INCH(DN150) SET AND OPEN POSITIONS TFP1020 Page 10 of 20 NOTES: • 1. SEE FIGURE 3 PART 3 FOR TRIM ARRANGEMENT WITH BILL OF MATERIALS LOW AIR AND COMPONENT PART NUMBERS. PRESSURE 2. TRIM SHOWN FULLY ASSEMBLED;COMPONENTS SUCH AS GAUGES AND ALARM SWITCHES MAY REQUIRE ASSEMBLY IN TRIM AT INSTALLATION. /SWITCH SYSTEM AIR SUPPLY 1 INCH NPT SYSTEM011 CONTROL VALVE AIR SUPPLY , (NORMALLY �> OPEN) FOR LOCAL PRESSURE "�'' SPRINKLER GAUGE ^�. ri 2-1/2 INCH(DN65) �,. ��' A WATERFLOW or 3 INCH(DN80) 1, �. PRESSURE 1/2 INCH NPT ii MODEL DPV-1 =/� )'3. S'; ALARM CONNECTION _ f �� L; DRY PIPE VALVE 1 .l r�s1 SWITCH FOR SYSTEM (GxG ONLY) a;!_ - .. AIR SUPPLY mA v. �� riot �w I GROOVED MAIN ��� � - CO COUPLING ALARM V.r! r TEST VALVE �� n DRAIN VALVE ���J\ (NORMALLY (NORMALLY 1/2 INCH NPT CLOSED) CONNECTION SYSTEM \ SYSTEM CLOSED) �� FOR OPTIONAL WATER 3/4INCH NPT SUPPLY CONNECTION SHUT-OFF 1-1/4 INCH NPT ACCELERATOR PRESSURE TO DRAIN VALVE CONNECTION GAUGE LOW BODY (NORMALLY TO DRAIN AUTOMATIC DRAIN VALVE OPEN) DRAIN VALVE (NORMALLY 1-1/4 INCH NPT CLOSED) CONNECTION DRIP TO DRAIN FUNNEL FIGURE 3-PART 1 OF 3 2-1/2 AND 3 INCH(DN65 AND DN80)MODEL DPV-1 DRY PIPE VALVE PRE-TRIMMED ASSEMBLY AIR SUPPLY 1/2 INCH NPT 1/2 INCH NPT NOTES: . CONTROL VALVE CONNECTION CONNECTION 1. INSTALL TRIM ASSEMBLIES IN (NORMALLY OPEN) FOR OPTIONAL FOR OPTIONAL ALPHABETICAL ORDER. ACCELERATOR AUTOMATIC AIR PRESSURE v 1/2 INCH NPT I QXG�DRAIN VALVE SWITCH 2. SEE FIGURE 2 FOR VALVE PORT IDENTIFICATION. CONNECTION FOR SYSTEM �' 3. ROUTE 1/4"TUBING TO DRIP FUNNEL. AIR SUPPLY . ryi SYSTEM '�'�/ 1 AIR SUPPLY MAIN Li V,/� A 1/2 INCH NPT �01 p = PRESSURE DRAIN VALVE CONNECTION //.':4:�;, GAUGE A (NORMALLY FOR WATERFLOW \��1� E CLOSED) PRESSURE ALARM � SWITCH .10', >" �7�i / 0,4 . ....‘ 'Ise li i 1-1/4 INCH NPT DRIP o �j, CONNECTION FUNNEL I -114 1 `� TO DRAIN �— —�` 1 �/ 1-1/4 INCH NPT ✓'i ( � CONNECTION �� ,�� +" ��/2 INCH(DN65) TO DRAIN 1 INCH NPT C p2 or 3 INCH(DN80) CONNECTION MODEL DPV-1 FOR LOCAL T S yi�e r�l, pa DRY PIPE VALVE SPRINKLER ►` rf C (GxG ONLY) iii f, F // '�'e''' LOW BODY ALARM I �: / B �=•�� DRAIN VALVE TEST VALVE ' SYSTEM (NORMALLY (NORMALLY WATER SUPPLY 3/4 INCH NPT CLOSED) CLOSED) PRESSURE CONNECTION GAUGE TO DRAIN FIGURE 3-PART 2 OF 3 2-1/2 AND 3 INCH(DN65 AND DN80)MODEL DPV-1 DRY PIPE VALVE EXPLODED ARRANGEMENT OF SEMI-ASSEMBLED TRIM TFP1 020 Page 11 of 20 • NO. DESCRIPTION QTY P/N NO. DESCRIPTION QTY P/N NO. DESCRIPTION QTY P/N 1 250 psi/1750 kPa 13 3/32"Vent 28 1"x 1"x 1/2" Air Pressure Fitting 1 92-032-1-002 Reducing Tee 1 CH Gauge 1 92-343-1-012 14 1/4"Tube, 29 Not Used 2 300 psi/2000 kPa 18"Long 1 CH PIPE NIPPLES: Water Pressure 15 1/4"Plug 2 CH 30 1/4"x 3" 2 CH Gauge 1 92-343-1-005 16 1/2"Plug 2 CH 31 1/2"x Close 4 CH 3 1/4"Gauge Test 17 1"Plug 1 CH 32 1/2"x 1-1/2" 8 CH Valve 2 46-005-1-002 18 1/2"Union 1 CH 33 1/2"x 2" 1 CH 4 Model AD-1 19 1/2"x 1/4"Reducing 34 1/2"x 4-1/2" 1 CH Automatic Bushing 1 CH 35 1/2"x 6" 1 CH Drain Valve 1 52-793-2-004 20 1/2"90°Elbow....3 CH 36 3/4"x Close 1 CH 5 1/4" Pressure 21 3/4"90°Elbow....1 CH 37 3/4"x 1-1/2" 1 CH Relief Valve 1 92-343-1-020 22 1-1/4"90°Elbow. ..1 CH 38 3/4"x 2-1/2" 1 CH 6 1/2"Ball Valve ....2 46-050-1-004 23 1/2"Cross 2 CH 39 1"x Close 1 CH 7 3/4"Angle Valve...1 46-048-1-005 24 1/2"x 1/2"x 1/4" 40 1-1/4"x Close ....1 CH 8 1-1/4"Angle Valve .1 46-048-1-007 Reducing Tee 1 CH 41 1-1/4"x 4" 1 CH 9 1/2"Swing 25 1/2"Tee 1 CH COMPONENTS INCLUDED ONLY IN Check Valve 2 46-049-1-004 26 1/2"x 1/4"x 1/2" PRE-TRIMMED VALVE ASSEMBLIES: 10 Drip Funnel Reducing Tee 2 CH Connector 1 92-211-1-005 27 1/2"x 1/2"x 3/4" 42 Model BFV-300 11 Drip Funnel Reducing Tee 1 CH Butterfly Valve, Bracket 1 92-211-1-003 2-1/2"(DN65) 1 59300G025WS 12 Drip Funnel 1 92-343-1-007 3"(DN80) 1 59300G030WS c') 45 43 Figure 577 Coupling, 2-1/2"(DN65) 1 57725ACP 16 3" (DN80) 1 57730ACP 44 Waterflow Pressure 20 Alarm Switch, 1 Model PS10-2 1 25710 9 19 32 30 45 Low Air Pressure 6 32 Alarm Switch, • 5 32 32 66. 23 Model PS40-2 1 25730 24 32 15 20 17 3� fJh 39 3 i �/ 28 44 �� '�� 33 1 2-1/2 INCH(DN65) a ' or 3 INCH(DN80) e)��` 9 C 16 4 MODEL DPV-1 25 � 31 27 , c 1" DRY PIPE VALVE a ,��1 (GxG ONLY) 31 LOCATION Or 23 FOR OPTIONAL e1�1`� 36 A41 18 ELECTRICALLY 8 10 ((��e 8 a1 ' 4 SUPERVISED 32 " 22 31 N.O.ALARM 20 r r 40 CONTROL 11 VALVE / 26 U 'C 13 12 37 NOTES: (GREEN 43 1. SEE FIGURE 2 FOR VALVE TINT) I 14 21 PORT IDENTIFICATION. ( 0 38 7 02 42 2. ROUTE 1/4"TUBING,ITEM 14, 31 t�rj TO DRIP FUNNEL,ITEM 12. 6 q�ii� �� ' I 3. ALL FITTINGS AND NIPPLES I' 32 (� 35 `, ARE GALVANIZED. 26 °� 2 `� (��� 4. CH:COMMON HARDWARE 30 4.:1, 5. ITEMS 42-45 INCLUDED 3 '�� '• ONLY IN PRE-TRIMMED VALVE ASSEMBLIES AS • APPLICABLE;OTHERWISE SEPARATELY ORDERED. FIGURE 3-PART 3OF3 2-1/2 AND 3 INCH(DN65 AND DN80)MODEL DPV-1 DRY PIPE VALVE EXPLODED ARRANGEMENT OF VALVE TRIM TFP102O Page 12 of 20 1. SEE FIGURE 4 PART 3 FOR TRIM ARRANGEMENT WITH BILL OF MATERIALS LOW AIR • AND COMPONENT PART NUMBERS. PRESSURE 2. TRIM SHOWN FULLY ASSEMBLED;COMPONENTS SUCH AS GAUGES AND ALARM SWITCHES MAY REQUIRE ASSEMBLY IN TRIM AT INSTALLATION. SWITCH SYSTEM AIR SUPPLY CONTROL VALVE 1/2 INCH NPT SYSTEM 4 INCH(DN100) (NORMALLY CONNECTION AIR SUPPLY MODEL DPV-1 •v>' FOR SYSTEM-- PRESSURE DRY PIPE VALVE �, OPEN) AIR SUPPLY 0 � � GAUGE (FxG SHOWN) � �. / 7�,' ` , �h,, 3/4 INCH NPT �' i � CONNECTION 1 INCH NPT ���� � FLANGE ADAPTER j ( 1 FOR WATER CONNECTION .n �.,`t- OR GROOVED '-,..*,,,MOTOR ALARM FOR LOCAL "v .,�,y A COUPLING f � SPRINKLER-i)l�,' /o' ,' /�'"~ �1 WATERFLOW t. �.� ��• MAIN �, y., Iv PRESSURE 3/4 INCH NPT ;�� -1 DRAIN VALVE 'I' �y„�;.•�'� ALARM CONNECTION • ;Isp/ (NORMALLY , TO DRAIN/ 4'y ` CLOSED) ����'-/ `" j 1/2 INCH NPT SWITCH s �, ‘0,1 / "� '! CONNECTION ALARM / \ I..\ __I� FOR OPTIONAL TEST VALVE 2 INCH NPT U\ACCELERATOR (NORMALLY SYSTEM CONNECTION LOW BODY SYSTEM SHUT-OFF TO DRAIN \ AUTOMATIC CLOSED) DRAIN VALVE WATER VALVE DRAIN VALVE (NORMALLY SUPPLY (NORMALLY CLOSED) PRESSURE OPEN) 1-1/4 INCH NPT GAUGE CONNECTION DRIP TO DRAIN FUNNEL FIGURE 4-PART 1 OF 4 INCH(DN100)MODEL DPV-1 DRY PIPE VALVE PRE-TRIMMED ASSEMBLY v l , 1/2 INCH NPT AIR SUPPLY • 10 CONNECTION CONTROL VALVE FOR OPTIONAL (NORMALLY k �, .. ACCELERATOR OPEN) 1/2 INCH NPT MAIN �i`;• SYSTEM DRAIN VALVE "' C•/�% %;! CONNECTION s M 1/2 INCH NPT AUTOMATIC AIR SUPPLY (NORMALLY CONNECTION FOR OPTIONAL DRAIN VALVE AIR PRESSURE PRESSURE CLOSED) FOR WATERFLOW 1 GAUGE SWITCH SLOPE PRESSURE ALARM / DON DOWN SWITCH \ 141 3/4 INCH NPT , 71 1 r 0 \ CONNECTION D 5 .. 711� FOR WATER +4° j�7 1 A - / '- MOTOR ALARM �1.0 •-AS` \ IN 0 5 U;\,r\ 'Iv i,,,._ , / 3 1 %i O 2INCHNPT 1/2 INCH NPT d 'I0 "1P' � CONNECTION CONNECTION � lU ��t('-- 0� / (% 4 TO DRAIN •FOR SYSTEM I `)%A� ,,. AIR SUPPLY c�,I I AI,-, �1 ' of, 1 t . < < y 4 INCH(DN100) ALARM �r �'� OQ 02 �Q�o MODEL DPV-1 1 DRY PIPE VALVE TEST VALVE I � r,,;, `� (FxG SHOWN) (NORMALLY �,�.-s CLOSED) ,1 \ 1 INCH NPT NOTES: 3/4 B CONNECTION 1. INSTALL TRIM ASSEMBLIES IN SYSTEM INCH NPT FOR LOCAL ALPHABETICAL ORDER. WATER SUPPLY CONNECTION SPRINKLER PRESSURE TO DRAT/ 2. SEE FIGURE 2 FOR VALVE PORT GAUGE LOW BODY IDENTIFICATION. DRIP DRAIN VALVE 3. ROUTE 1/4'TUBING TO DRIP FUNNEL. FUNNEL 1-1/4 INCH NPT (NORMALLY 4. SLOPE ASSEMBLY B DOWN TOWARD CONNECTION CLOSED) BACK OF VALVE TO FACILITATE TO DRAIN SUFFICIENT LOW BODY DRAINAGE. FIGURE 4-PART 2OF3 III INCH(DN100)MODEL DPV-1 DRY PIPE VALVE EXPLODED ARRANGEMENT OF SEMI-ASSEMBLED TRIM TFP1020 Page 13 of 20 • " /1` ,�\ 47 16 48 NOTES: 1 1. SEE FIGURE 2 FOR VALVE PORT IDENTIFICATION. i. 411111p,,.. -•;• 28 18 ' " / ; 6 2. ROUTE 1/4"TUBING, ITEM 16, A/Is ,r 4 5 c" i°r 15 27 TO DRIP FUNNEL,ITEM 14. =. �, (tiy 34t (GREEN 3. SLOPE 3/4"ANGLE VALVE. TINT) 12 ITEM 9,DOWN TOWARD SLOPE 9 29 ~ 34 18 14 BACK OF VALVE TO DOWN 34 26 FACILITATE SUFFICIENT 8 LOW BODY DRAINAGE. 19 l ,SIP 34 27 34 4. ALL FITTINGS AND NIPPLES LOCATION 111 :1 30 36 ` �\\� ARE GALVANIZED. FOR OPTIONAL „� 21 1 5. CH:COMMON HARDWARE N ELECTRICALLY ,) ��� r 32 17 13 6. ITEMS 45-48 INCLUDED SUPERVISED yyv��� �� ONLY IN PRE-TRIMMED N.O.ALARM 41 r +„''' 30 it 3 VALVE ASSEMBLIES AS CONTROL sl��\� 39 40 ��� ' APPLICABLE;OTHERWISE VALVE 10 /��� 03 i SEPARATELY ORDERED. °�1,v 39 04 23 �� 30 1 40 1 , 4 4 INCH(DN100) 24 34 i � ��� 34 43 :f1 MODEL DPV-1 �9.tiz��� 01 �� a DRY PIPE VALVE 33 42 31� �� ,,I j� �� (FxG SHOWN) �� 'r� y ell ' �'.y � r �i 25 Zi 7 38 20 �i� 0� J 33 t�f q 11 �p 46 �(( , ,l y:��-wee ti) 37 et o ���� .4 2 0 .0 0y 11 NO. DESCRIPTION QTY P/N , c-, 22 /�, i . 44 . 1 250 psi/1750 kPa 28 / - 3 45 Air Pressure . Gauge 1 92-343-1-012 35 32 a�';�<. 17 'jr��� li 2 300 psi/2000 kPa ,y%� ' `1 Water Pressure `S` Gauge 1 92-343-1-005 ICI, 3 1/4"Gauge Test NO. DESCRIPTION QTY P/N +, Valve 2 46-005-1-002 4 1/4"Pressure 21 1/2"x 1/4"Reducing Relief Valve 1 92-343-1-020 Bushing 1 CH NO. DESCRIPTION QTY P/N 5 1/2"Angle Valve...1 46-048-1-004 22 1/2'Union 1 CH 6 Model AD-1 23 3/4'Union 1 CH 41 3/4"x 2" 1 CH 1 Automatic 24 1/2"90°Elbow....1 CH 42 3/4"x 3" 1 CH Drain Valve 1 52-793-2-004 25 1/2"45°Elbow....1 CH 43 1"x 4" 1 CH 7 1/2" Ball Valve ....1 46-050-1-004 26 1/2"Cross 1 CH 44 2"x 4-1/2" 1 CH 8 1/2"Swing 27 1/2"Tee 2 CH COMPONENTS INCLUDED ONLY IN Check Valve 1 46-049-1-004 28 1/2"x 1/4"x 1/2" PRE-TRIMMED VALVE ASSEMBLIES: 9 3/4"Angle Valve...1 46-048-1-005 Reducing Tee 2 CH 10 3/4"Swing 29 1/2"x 1/2"x 1/4' 45 Model BFV-300 Butterfly Check Valve 1 46-049-1-005 Reducing Tee 1 CH Valve,4"(DN100)..1 59300G040WS 11 2"Angle Valve .... 1 46-048-1-009 30 3/4"x 1/2"x 3/4" 46 Butterfy Valve 12 Drip Funnel Reducing Tee 3 CH Assembly Component: Connector 1 92-211-1-005 31 1"x 1"x 1/2" GxG DPV-1 Valves, 13 Drip Funnel Reducing Tee 1 CH Figure 577 Coupling, Bracket 1 92-211-1-003 PIPE NIPPLES: 4"(DN100) 1 57740ACP 14 Drip Funnel 1 92-343-1-007 32 1/4"x 3" 2 CH FxF,FxG DPV-1 Valves, 15 3/32"Vent 33 1/2"x Close 2 CH Figure 71 Flange Adapter, Fitting 1 92-032-1-002 34 1/2"x 1-1/2" 7 CH 4" (DN100) 1 7140S 16 1/4"Tube, 35 1/2"x 2" 1 CH 47 Waterflow Pressure 24'Long 1 CH 36 1/2"x2-1/2" 1 CH Alarm Switch, 17 1/4"Plug 2 CH 37 1/2"x 3" 1 CH Model PS10-2 1 25710 18 1/2"Plug 2 CH 38 1/2"x 3-1/2" 1 CH 48 Low Air Pressure III 19 3/4"Plug 1 CH 39 3/4"x Close 2 CH Alarm Switch, 20 1'Plug 1 CH 40 3/4" x 1-1/2" 2 CH Model PS40-2 1 25730 FIGURE 4- PART 3OF3 4 INCH(DN100)MODEL DPV-1 DRY PIPE VALVE EXPLODED ARRANGEMENT OF VALVE TRIM TFP1 020 Page 14 of 20 NOTES: • 1. SEE FIGURE 5 PART 3 FOR TRIM ARRANGEMENT WITH BILL OF MATERIALS LOW •AIR AND COMPONENT PART NUMBERS. PRESSURE 2. TRIM SHOWN FULLY ASSEMBLED;COMPONENTS SUCH AS GAUGES AND ALARM SWITCHES MAY REQUIRE ASSEMBLY IN TRIM AT INSTALLATION. SWITCH SYSTEM AIR SUPPLY SYSTEM 0 / CONTROL VALVE AIR SUPPLY Ky (NORMALLY OPEN)LY 1/2 INCH NPT _ PRESSURE Ili CONNECTION GAUGE • FOR SYSTEM r SYSTEM ) LOW BODYL WATER „Amp*,1 DRAIN VALVE AIR SUPPLY ♦ SUPPLY ��1 ,� G.\ (NORMALLY �)i► -, PRESSURE T 4 ' i CLOSED) 1 INCH NPT V•- -i-- GAUGE (CONNECTION )i, ' , ,>: AUTOMATIC FOR LOCALGROOVED I�(ik DRAIN VALVE SPRINKLER', l COUPLING i JI �`1� \ � \ �� OR FLANGE �Ia'��� &'.�+ � ` 1/2 INCH NPT DRIP FUNNEL - •� 1c�, ADAPTER ql= �,I• arc.-lye.- I'' 'L- LfV* A " �.y..��'3• s .),�.� low CONNECTION i 1 f,�,4 3""3 V3 FOR OPTIONAL u ,,_ MAIN �' � -"� ACCELERATOR DRAIN VALVE ALARM � (NORMALLY 2 INCH NPT \ TEST VALVE I 1-1/4 INCH NPT CLOSED) CONNECTION 6 INCH(DN150) SHUT OFF (C OSED)Y WATERFLOW 3/4 INCH NPT PR SURE CONNECTION TO DRAIN MODEL DPV-1 VALVE CONNECTION ALARM TO DRAIN DRY PIPE VALVE (NORMALLY FOR WATER SWITCH (GxG SHOWN) OPEN) MOTOR ALARM FIGURE 5-PART 1 OF 3 6 INCH(DN150)MODEL DPV-1 DRY PIPE VALVE PRE-TRIMMED ASSEMBLY 1/2 INCH NPT 1/2 INCH NPT NOTES: B n CONNECTION CONNECTION 4. SLOPE 3/4"ANGLE VALVE AND FOR OPTIONAL FOR SYSTEM 1" 21 3/4"x 4-1/2"NIPPLE(OF ASSEMBLY B) Lip i ��� SYSTEM AIR PRESSURE AIR SUPPLY -- INTO DRIP FUNNEL TO FACILITATE AIR SUPPLY SWITCH SUFFICIENT LOW BODY DRAINAGE. Fy� -- PRESSURE 4 AIR SUPPLY DRIP GAUGE \�� (` CONTROL VALVE LOW BODY 1/2 INCH NPT FUNNEL-- �� (NORMALLY DRAIN VALVE CONNECTION SLOPE 1 INCH NPT S ��, OPEN) (NORMALLY FOR OPTIONAL TO FIT CONNECTION V %1i'' "`' CLOSED) ACCELERATOR 1/2 INCH NPT FOR LOCAL �' CONNECTION SPRINKLER -�V�o A �� / AUTOMATIC FOR WATERFLOW DRAIN VALVE o o , r PRESSURE ALARM . 9., / (C o1 Ir \ SWITCH 41 I �^ o o ro,-., 3/4 INCH NPT MAIN �� 01 B CONNECTION DRAIN VALVE I 01 \ FOR WATER (NORMALLY Og �� rii . MOTOR ALARM CLOSED) D 0-, 1� ell / n ir�,1� �.ty/ 2 INCH NPT '\`\' ' 03 0it 1 ,/.�i CONNECTION 6 E(DN150) . \. TO DRAIN MODEL DPV-1 \J DRIP DRY PIPE VALVE �' , FUNNEL �� C NOTES: (FxF SHOWN) •�•�;o_ O//`L 0 R, 1. INSTALL TRIM ASSEMBLIES IN 2 i �71 ALPHABETICAL ORDER. /� .5_I. \ ALARM 2. SEE FIGURE 2 FOR VALVE PORT 1-1/4 INCH NPT ��G SYSTEM TEST VALVE IDENTIFICATION. CONNECTION WATER SUPPLY (NORMALLY 3. ROUTE 1/4"TUBING TO DRIP TO DRAIN PRESSURE CLOSED) IIIFUNNEL. GAUGE FIGURE 5-PART 2 OF 3 6 INCH(DN150)MODEL DPV-1 DRY PIPE VALVE EXPLODED ARRANGEMENT OF SEMI-ASSEMBLED TRIM TFP1020 Page 15 of 20 4111 9 (; BACK OF 1 4 NOTES: 1. SEE FIGURE 2 FOR VALVE 4. ALL FITTINGS AND NIPPLES (! I VALVE 29 PORT IDENTIFICATION. ARE GALVANIZED. 42 ` _ /`�C 35 2. ROUTE 1/4"TUBING, ITEM 16, 5. CH:COMMON HARDWARE 14 1 y y�yr / 5 TO DRIP FUNNEL,ITEM 14. 6. ITEMS 45-48 INCLUDED 3. SLOPE 3/4"ANGLE VALVE, ONLY IN PRE-TRIMMED SLOPE-� 48 18 " ITEM 9,AND 3/4"x 4-1/2" VALVE ASSEMBLIES AS '\all ��� NIPPLE, ITEM 42,INTO APPLICABLE;OTHERWISE TO FIT „ ' 35 DRIP FUNNEL,ITEM 14,TO SEPARATELY ORDERED. 26 � ,� 8 fir'! FACILITATE SUFFICIENT 15 1 21 2 `j7 '` " i 40 LOW BODY DRAINAGEIa. . (GREEN LOCATION 3 = , 35 y//C 18 ,i FOR OPTIONAL „' S 9 = • g1` <40$4. 35 ELECTRICALLY 17 '';`" /(( 35 I 30 Ti." 27 .., SUPERVISED ,• 33 42 6 / 47 N.O.ALARM 1 11 20 �f 1 43 27 /Iiir 35 16 P8 ~s y CONTROL I(...III.--- ) I % `y �ye VALVE ir�F 32 100.43 (� 3100) 37 it 04 40 i � 40 t(C 10 (111 NINO. S 0g ° ,� 40 i r 41 19 \ //e 6 INCH(DN150) r�� al 23 �j MODEL DPV-1 DRY PIPE VALVE �10 1 03 42 12 -'C (GxG SHOWN) l.�� 40 yr . Al ��� 13 31 NS. NO. DESCRIPTION QTY P/N , ��. 39 14 38 35 N 24 1 250 psV 1750 kPa 02 �i` 22 7 itk 34 Air Pressure 36 35 ,y/� 25 Gauge 1 92-343-1-012 3y� y�� 28 �N�+ 2 300 psi/2000 kPa 2 ; J\, "' y "�� • Water Pressure Rie ,av j Gauge 1 92-343-1-005 l71 3 1/4"Gauge Test nry� Valve 2 46-005-1-002 e 33 4 1/4"Pressure 46 3 Relief Valve 1 92-343-1-020 17 NO. DESCRIPTION QTY P/N 5 1/2"Angle Valve...1 46-048-1-004 45 35 1/2"x 1-1/2" 8 CH 6 Model AD-1 ���6 36 1/2"x 2" 1 CH Automatic 37 1/2"x 2-1/2" 1 CH Drain Valve 1 52-793-2-004 0�� 38 1/2"x 3" 1 CH 7 1/2"Ball Valve ... .1 46-050-1-004 �- 39 1/2"x 6" 1 CH 8 1/2"Swing .� 1 `- /� 40 3/4"x 1-1/2" 5 CH Check Valve 1 46-049-1-004 �' /Il�� 41 3/4"x 2" 1 CH 9 3/4"Angle Valve...1 46-048-1-005 ,,, - `r 42 3/4"x 4-1/2" 2 CH 10 3/4"Swing 43 1"x 4" 1 CH Check Valve 1 46-049-1-005 44 2"x 4-1/2" 1 CH 11 2"Angle Valve ....1 46-048-1-009 COMPONENTS INCLUDED ONLY IN 12 Drip Funnel PRE-TRIMMED VALVE ASSEMBLIES: Connector 1 92-211-1-005 NO. DESCRIPTION QTY P/N 13 Drip Funnel 45 Model BFV-300 Butterfly Bracket 1 92-211-1-003 25 1/2"45°Elbow....1 CH Valve,6"(DN150). .1 59300G060WS 14 Drip Funnel 1 92-343-1-007 26 1/2"Cross 1 CH 46 Butterfy Valve 15 3/32"Vent 27 1/2"Tee 2 CH Assembly Component: Fitting 1 92-032-1-002 28 1/2"x 1/4"x 1/2' GxG DPV-1 Valves, 16 1/4"Tube, Reducing Tee 2 CH Figure 577 Coupling, 24"Long 1 CH 29 1/2"x 1/2"x 1/4" 6"(DN150) 1 57760ACP 17 1/4"Plug 2 CH Reducing Tee 1 CH FxF,FxG DPV-1 Valves, 18 1/2'Plug 2 CH 30 3/4"90°Elbow....1 CH Figure 71 Flange Adapter, 19 3/4"Plug 1 CH 31 3/4"x 1/2"x 3/4" 6"(DN150) 1 7160S 20 1"Plug 1 CH Reducing Tee 3 CH 47 Waterflow Pressure 21 1/2"x 1/4"Reducing 32 1"x 1"x 1/2" Alarm Switch, Bushing 1 CH Reducing Tee 1 CH Model PS10-2 1 25710 22 1/2"Union 1 CH PIPE NIPPLES: 48 Low Air Pressure • 23 3/4"Union 1 CH 33 1/4"x 3" 2 CH Alarm Switch, 24 1/2"90°Elbow....1 CH 34 1/2"x Close 1 CH Model PS40-2 1 25730 FIGURE 5-PART 3OF3 6 INCH(DN150)MODEL DPV-1 DRY PIPE VALVE EXPLODED ARRANGEMENT OF VALVE TRIM TFP1020 Page 16 of 20 y 7-1/8" 8-3/8" 14-7/8" 9-1/4" F • (180 mm) I (213 mm) (380 mm) (235 mm) ! • Li, ! �Q 2-1/2&3INCH ■ 51•151 Y:0,. [ia*�r iiI'•' (DN65&DN80) 20-7/16" _ • VALVE or (520 mm) PT! it 1 I !i. ' ���i�='1 2-1/2 or3INCH '010 1,•-•ap -• I db �II5 � ii.�'I VALVES I`:o�Il -,�0� L_ r iffiv ; Its_ r, if �r = ' 1 4) -Lii 1.--- i W 12" 9-5/8" _ 12" 14" (300 mm) I (245 mm)i (300 mm) (355 mm) ! —� !r© 4 INCH I l�i6iiilrIr�*. ICI _!"-Iip J (DN100) • • �s VALVE 1 ""' • 21-7/8" 'Ar ■1 , � li (555 mm) ' • • dy II FxF:18-3/16"(462 mm) ©��s,i�• 1,PZI 1 Iq�. .`I' FxG: 18-1/4" (464 mm) I'i�!d11 • l� 'r . iiil�11117 �IMIr GxG:18-5/16"(465 mm) I••O. ir.p= 11-11 1111 —i©-.--- 71 / II 1 1 w 11-1/2" 11-3/8" _ 15" 14-3/4" _ (290 mm) (289 mm) (380 mm) (375 mm) ■ III 6 INCH ! —.Tim !- (DN150) iaM • :, / VALVE • • i ■ + oli �� 24-1/2" • i i I I (620 mm) �I� o c �I'I L� D Q `_i-:. (555,6 mm) I'— i•! pP1!'d'!IPir ' LJ . 14 ■—� W -� . � TES WIC ° � II 1 FIGURE 6-PART 1 OF 2 • MODEL DPV-1 DRY PIPE VALVE INSTALLATION DIMENSIONS, PRE-TRIMMED VALVE TFP1O2O Page 17 of 20 • 6-3/4" 8" 14-7/8" 9-1/4" (170 mm) (200 mm) (380 mm) (235 mm) Ul t 1 * 16 9/16" 2-1/2&3 INCH Qi ii � 1:i" , 1 a7 ,_�:: ,;, T [����■iiill� (DN65&DN80) (420,7 mm) 9 VALVE — * 12-1/4" -Alf o� 2-1/2 or 3 INCH Willir tom �1 �M1�■,Ii—I VALVES .go, i !_• • o I.-� .�.• ! = q P o� ii 6" (150 mm) t 12" 6" 12" 14" (300 mm) (150 mm) (300 mm) (355 mm) ! t ! 41, 4 INCH . ■i-■1i� * 17-,/4" (440 mm) MI . 1!—,I1 .) — — (DN100) VALVE � '•-,_'7. i; FxF:13-5/8 (346,1 mm) Iiio7. ito ItFGxGxG: 1:31-31-13//146334497,3mm)) ©Mga� IP ■■ ir.- 2-1/2"(65 mm) - I 11-1/2" 7-1/4' 15' 14-3/4" 7 (290 mm) (190 mm) (380 mm) (375 mm) 6 INCH �_ 10) (DN150) 1•"i■i^ii•���• 18-3/4" / VALVE NI (475 mm) - T * 16" AN* 1' (406,4 mm) )'� . ill T FxF,FxG, ii. ��� or GxG —ICI'' t �%!i[ (•- �I .1 11��� �� © �1,1R1 it �.,I d b t, h PIS 11-11111MpmfmmAitim. 4-1/2" W (115 mm) W FIGURE 6-PART 2OF2 • MODEL DPV-1 DRY PIPE VALVE INSTALLATION DIMENSIONS, VALVE AND SEMI-ASSEMBLED TRIM TFPIO2O Page 18 of 20 Care and Step 3. Verify that the DPV-1 Valve has operated, as indicated by the flow Nominal Torque1111 Maintenance of water into the system and that all Valve Sizes lb waterflow alarms operate properly. (pN) (N•m) The following procedures and inspec- Step 4.Close the system Main Control 2-1/2 tions should be performed as indicated, Valve. (DN65) (410) in addition to any specific requirements Step 5. Reset the DPV-1 Valve in of the NFPA,and any impairment must 3 30 accordance with the Valve Setting DN80 (41)immediately corrected. Procedure. ( ) ( ) Before closing a fire protection system Note: It is recommended that the 4 30 main control valve for maintenance (DN100) (41) requirement of NFPA 25 to annually work on the fire protection system that inspect the inside of the valve be per- 6 55 it controls,permission to shut down the DN150) (75) formed at this time and p rior to reset- t affected fire protection system must be frog the DPV-1 Valve. Refer to the obtained from the proper authorities Automatic Drain Valve Inspection sub- TABLE C and notify all personnel who may be HANDHOLE COVER BOLTS section Steps 2 through 5 for instruc affected by action. tions with regard to the inspection of MAXIMUM TORQUE The owner is responsible for the the Clapper Facing. inspection,testing,and maintenance of Quarterly Waterflow Alarm Test Gauge), and then after removing the their fire protection system and devices Procedure Handhole Cover, perform the follow- in compliance with this document, as ing steps: well as with the applicable standards Testing of the system waterflow alarms of the National Fire Protection Associa- should be performed quarterly.To test Step 1. Make sure that the Seat Ring tion (e.g., NFPA 25), in addition to the the waterflow alarm, open the Alarm is clean and free of any nicks or signifi- standards of any authority having juris- Test Valve, which will allow a flow of cant scratches. diction. Contact the installing contrac- water to the Waterflow Pressure Alarm Step 2. Remove the Clapper Assem- tor or sprinkler manufacturer regarding Switch and/or Water Motor Alarm. bly from the valve by first pulling out any questions. Upon satisfactory completion of the the Hinge Pin. test,close the Alarm Test Valve. Automatic sprinkler systems are rec- Step 3. Disassemble the Clapper ommended to be inspected, tested, Water Pressure Inspection Facing Retainer from the Clapper and maintained by a qualified Inspec- The Water Pressure Gauge is to be so that the Clapper Facing can be tion Service in accordance with local inspected monthly (per NFPA 25) to removed and inspected. Make sure • requirements and/or national codes. ensure that normal system water pres- that the Clapper Facing does not show sure is being maintained. signs of compression set,damage,etc. The operational test procedure and Replace Clapper Facing if there is waterflow pressure alarm test pro- Air Pressure Inspection Reply signs thef Clw a p cedure will result in operation of the The Air Pressure Gauge is to be any associated alarms. Consequently, inspected monthly (per NFPA 25) to Step 4. Clean the Clapper Facing, notification must first be given to the ensure that normal system air pressure Clapper,and Clapper Facing Retainer, owner and the fire department, central is being maintained. and then reassemble the Clapper station,or other signal station to which Automatic Drain Valve Inspection Assembly. the alarms are connected. The Automatic Drain Valve should be Step 5.Reinstall the Clapper Assembly Annual Operation Test Procedure inspected monthly (per NFPA 25) by with its Hinge Pin. Note:Unless otherwise noted, refer to depressing the plunger and check- Step 6. Install Handhole Cover: Figure 3, 4, or 5 to identify functional ing to ensure that the Automatic Drain trim components. Valve is not discharging water and/or a. Align Handhole Cover Gasket and air. A discharge of water and/or air is Handhole Cover in proper orien- Proper operation of the DPV-1 Valve an indication that the air and/or water tation with valve body(Ref.Figure (i.e.,opening of the DPV-1 Valve during seats are leaking, which could subse- 1)and hold in place a fire condition) should be verified at quently cause a false operation should least once a year as follows: the intermediate chamber become b. Apply LOCTITE No.242(or equiv- Step 1. If necessary, prevent water inadvertently pressurized. alent)to Hex Bolt threads from flowing beyond the riser by: If leakage is present, take the DPV-1 c. Insert Hex Bolts through Hand- • Close the Main Control Valve Valve out of service (i.e., close the hole Cover Gasket and Handhole main control valve,open the main drain Cover, hand-tighten into valve • Open the Main Drain Valve valve,close the air supply control valve, body • Open the Main Control Valve one turn remove the Dry Pipe Valve Accelerator d. Using crossdraw sequence to beyond the position at which water from service, as applicable, in accor- assure uniformity,wrench-tighten just begins to flow from the Main dance with its Technical Data Sheet Hex Bolts to appropriate torque Drain Valve (Refer to TFP1105 for the VIZOR or values(Ref.Table C) • Close the Main Drain Valve TFP1112 for the ACC-1), and open the e. Inspect to assure all Hex Bolts Inspector's Test Connection to relieveare securely tightened Step 2. Open the system Inspector's the system air pressure to 0 psig as Test Connection. indicated on the System Air Pressure • TFP1020 Page 19 of 20 • Limited Specify:6 in.DPV-1 Pre-Trimmed Valve Accessories Assembly, (specify) End Connection, Refer to Technical data Sheets describ- Warranty P/N(specify): ing the following accessories, as Flange x Flange 52-310-3-060 applicable. For warranty terms and conditions,visit Flange x Groove 52-310-3-460 Specify: Description, P/N (specify): www.tyco-fire.com. Groove x Groove 52-310-3-960 Model PS10-2 Potter Electric Watertlow Pre-Trimmed DPV-1 Assemblies Pressure Alarm Switch 25710 Ordering without Butterfly Valve (Ref.Potter Electric Technical Data Sheet) Specify:4 in.DPV-1 Pre Trimmed Valve Model PS40-2 Potter Electric Low Air Pressure Alarm Switch 25730 Assembly y without Butterfly, (specify) (Ref.Potter Electric Technical Data Sheet) End Connection, P/N(specify): Model WMA-1 Contact your local distributor for avail- Flange x Flange 52-310-4-040 Water Motor Alarm 52-630-1-001 ability.When placing an order.indicate Flange x Groove 52-310-4-440 (Ref.Technical Data Sheet TFP921) the full product name and Part Number Model AMD-1 (P/N). Specify:6 in.DPV-1 Pre Trimmed Valve Air Maintenance Device 52-324-2-002 Standard DPV-1 DryPipe Valve Assembly without Butterfly, (specify) Model AMD-2• ef 1 Data Sheet TFP1221) p End Connection, P/N(specify): ANSI standard outside diameter(O.D.) Air Maintenance Device 52-326-2-001 pipe size with grooved or ANSI drilled Flange x Flange 52-310-4-060 (Ref.Technical Data Sheet TFP1231) flange end connections and NPT Flange x Groove 52-310-4-460 Model AMD-3 9 Nitrogen Maintenance Device....52-328-2-001 threaded ports. Standard Galvanized (Ref.Technical Data Sheet TFP1241) Semi-Assembled DPV-1 Trim Specify: (specify size) Model DPV-1 Replacement Valve Parts DryPipe Valve with(specify)End Con- Note: Valves with NPT threaded ports Specify: P ( P Y) are intended for use with the Standard p Y (description) for use with nections, P/N(specify): Galvanized Semi-Assembled DPV-1 (specify size) Model DPV-1 Dry Pipe Groove x Groove, Valve Trim described in Figures 3, 4 Valve, P/N(see Figure 1). ANSI 2.88 in.(73,1 mm)O.D.Grooves: and 5 of this document. Replacement Trim Parts 2-1/2 in.(DN65)G x G 52-310-1-925 GroovexGroove, Specify: 2-1/2 and 3 in. DPV-1 Specify: (description) for use with ANSI 3.50 in.(88,9 mm)O.D.Grooves: Semi-Assembled Galvanized Trim, (specify size) Model DPV-1 Dry Pipe 3 in.(DN80)G x G 52-310-1-930 P/N 52-309-2-005 Valve, P/N(see Figures 3,4, or 5). Groove x Groove, ANSI 4.50 in.(114,3 mm)O.D.Grooves: Specify: 4 in. DPV-1 Semi-Assembled Other DPV-1 Dry Pipe Valves 4 in.(DN100)G x G 52-310-1-940 Notes: Other DPV-1 Dry Pipe Valves • Flange x Groove, Galvanized Trim, P/N 52-309-2-001 are valves ordered with any combi- ANSI Flange x ANSI 4.50 in.(114.3 mm)o.D. Specify: 6 in. DPV-1 Semi-Assembled nation of flange drilling, pipe groove Groove: Galvanized Trim, P/N 52-309-2-002 outside diameter O.D. port thread 4 in.(DN100)F x G 52-310-1-440 �� or Flange x Flange, Optional Electronic Accelerator: specification not offered as Standard ANSI Flanges: DPV-1 Dry Pipe Valves. 4 in.(DN100)F x F 52-310-1-040 VIZOR Electronic Dry Pipe Groove xGroove, Accelerator(with Trim) Valves with NPT threaded ports are ANSI 6.62 in.(168,3 mm)O.D.Grooves: (Ref.Technical Data Sheet TFP1105) intended for use with the Standard 6 in.(DN150)G x G 52-310-1-960 Galvanized Semi-Assembled DPV-1 FlangexGroove, Specify: VIZOR Electronic Dry Pipe Valve Trim described in Figures 3, 4 ANSI Flange x ANSI 6.62 in.(168,3 mm)0.D. Accelerator for use with the 4 or 6 in. and 5 of this document. Valves with ISO Groove: TYCO Model DPV-1 Dry Pipe Valve threaded ports are intended for use 6 in.(DN150)F x G 52-310-1-460 Trim, P/N 52-312-3-001 Flange x Flange, with special order trim that is provided ANSI Flanges: Optional Mechanical Accelerator: by local distributors to meet the spe- 6 in.(DN150)F x F 52-310-1-060 Model ACC-1 Dry Pipe Accelerator cific needs of certain localities. Please Pre-Trimmed DPV-1 Assemblies (Ref.Technical Data Sheet TFP1112) contact your local distributor regard- with Butterfly Valve Specify: Model ACC-1 DryPie ing valves and valve trim for specific Specify: 2-1/2 in. DPV-1 Pre Trimmed Accelerator, P/N 52-311-1-001, localities. Valve Assembly,Grooved End Connec- and Galvanized Accelerator Trim Specify: (specify size) Model DPV-1 tions, P/N 52-310-3-925 for Model DPV-1 Dry Pipe Valve, Dry Pipe Valve with(specify)End Con- Specify:3 in.DPV-1 Pre-Trimmed Valve P/N 52-311-2-010 nections and (specify NPT or ISO) Assembly, End Connections, threaded ports, P/N(specify): Y Optional 600 PSI Water Pressure P/N 52-310-3-930 Gauge: Other 2-1/2 in.(DN65)Valves Specify:4 in.DPV-1 Pre-Trimmed Valve Specify: 600 PSI Water Pressure with NPT Threaded Ports Assembly, (specify) End Connection, Gauge, P/N 92-343-1-004 Groove x Groove, 3.00 in.(76,1 mm)O.D. P/N(specify): Grooves 52-309-1-930 Flange x Flange 52-310-3-040 Flange x Groove 52-310-3-440 Groove x Groove 52-310-3-940 • TFP1020 Page 20 of 20 Other 2-1/2 in.(DN65)Valves Other 4 in. (DN100)Valves Other 6 in. (DN150)Valves with ISO Threaded Ports with ISO Threaded Ports with ISO Threaded Ports 4111 Groove x Groove, Groove x Groove, Groove x Groove, ANSI 2.88 in.(73,0 mm)O.D. ANSI 4.50 in.(114,3 mm)O.D. ANSI 6.62 in.(168,3 mm)0.0. Grooves 52-309-1-920 Grooves 52-309-1-923 Grooves 52-309-1-925 Grooves Groove, Flange x Groove, Groove x Groove, 3.00 in.(76,1 mm)0.0. ISO Flanges ANSI 4.50 in.(114,3 mm)0.0. 6.50 in.(165,1 mm)0.0. Grooves 52-309-1-940 Groove 52-309-1-213 Grooves 52-309-1-945 Flange x Flange. Flange x Groove, Other 3 in.(DN80)Valves ISO Flanges 52-309-1-113 ISO Flanges ANSI 6.62 in.(168,3 mm)0.0. with ISO Threaded Ports Groove 52-309-1-215 Groove x Groove, Other 6 in.(DN150)Valves Flange x Groove, ANSI 3.50 in.(88,9 mm)0.0. with NPT Threaded Ports ISO Flange x 6.50 in.(165,1 mm)0.0. Grooves 52-309-1-922 Groove x Groove, Groove 52-309-1-315 , 6.50 in.(165,1 mm)0.0. Flanges Flange, ' Other 4 in.(DN100)Valves Grooves 52-309-1-935 ISO Flanges 52-309-1-115 , with NPT Threaded Ports Flanges Groove, . Flanges Groove, ANSI Flange x 6.50 in.(165,1 mm)0.0. , ISO Flange x ANSI 4.50 in.(114,3 mm)0.0. Groove 52-309-1-435 1 Groove 52-309-1-253 Flanges Groove, Flanges Groove, ISO Flange x ANSI 6.62 in.(168,3 mm)0.D. AS Flange x ANSI 4.50 in.(114,3 mm)0.0. Groove 52-309-1-255 Groove 52-309-1-613 Flanges Groove. Flange x Groove, ISO Flange x 6.50 in.(165,1 mm)0.0. JIS Flange x ANSI 4.50 in.(114,3 mm)O.D. Groove 52-309-1-335 Groove 52-309-1-813 Flange x Groove, Flange x Flange, AS Flange x ANSI 6.62 in.(168,3 mm)0.0. ISO Flanges 52-309-1-133 Groove 52-309-1-615 Flange x Flange, Flanges Groove, AS Flanges 52-309-1-513 AS Flange x 6.50 in.(165,1 mm)0.0. Flange x Flange, Groove 52-309-1-635 Flange x Groove, JIS Flanges 52-309-1-713 JIS Flange x ANSI 6.62 in.(168,3 mm)0.0. Groove 52-309-1-815 Flange x Groove, JIS Flange x 6.50 in.(165,1 mm)0.D. Groove 52-309-1-835 Flange x Flange, ISO Flanges 52-309-1-135 Flange x Flange, AS Flanges 52-309-1-515 0 Flange x Flange, JIS Flanges 52-309-1-715 III 1400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 0201!Johnson Controls.All rights reserved.All epecifications end Other Information shown ware current as of document revision date and are subject to change without notice. Johnson Vikv WOIONAL HIE PROTECTION ASSOCIATION end NIPS 515 reglaterea barna/1U of Natonal Firs Protection Asraciatign, LOCIITE Is a regbteted eradeenexc of Henkel Corporation Controls VicOWorldwide Fire Protection Contacts www.tyco-fire.com • Products Model AMD-1 Automatic Air Maintenance Device Pressure Reducing Type with Field-Adjustable Pressure Regulator General Technical Description Data The TYCO Model AMD-1 Automatic Air Approvals Maintenance Device is an automatic, UL and C-UL Listed field-adjustable, pressure reducing FM Approved - --K .n device. It is used to control the pres- NYC Approved under MEA 206-02-E sure in a dry pipe sprinkler system,pre- Maximum Inlet Air(or Nitrogen) action system, or dry pilot line system Supply Pressure `¢ - of a drypilot actuated deluge orpreac- psi( bar) P 9 200 13,8 tion valve. Field-Adjustable Outlet Pressure The Model AMD-1 Device is utilized Range in applications where there is a com- 5 to 70 psi(0,4 to 4,8 bar) pressed air (or nitrogen) source con- trolled at a higher pressure than the Assembly desired system pressure. Pressure Major components illustrated in Figure sources include plant air supplies with 1 are factory assembled with galva- Installation their own automatic compressor con- nized steel nipples and malleable iron • trols or nitrogen supplies with single- pipe fittings. The TYCO Model AMD-1 Automatic stage, cylinder mounted pressure Operation Air Maintenance Device should be regulators. installed in the horizontal position as The Model AMD-1 Automatic Air Main- shown in figure 1, as well as in accor- tenance Device is a re-designation for The By-Pass Valve in the Model AMD-1 dance with the following instructions: the Central Model D-2, Gem Model Automatic Air Maintenance Device is F324,and Star Model S460. opened to quickly fill the system during NOTICE initial pressurization.Once the required Moisture build-up can adversely affect NOTICE system pressure has been reached, Suitable consideration the By-Pass Valve is closed and the performance.ust be given to the removal ofexces- The Model AMD-1 Automatic Air Main- Air Supply Control Valve is left open to sive moisture from the compressed air tenance Devices described herein must place the Model AMD-1 Device in auto- supply. be installed and maintained in compli- matic operation. ance with this document and with the When there is a small leak in the 1. Make connections a minimum of applicable standards of the National system, the Pressure Regulator auto- 1/2 inch(DN15)pipe size between Fire Protection Association, in addi- the inlet air supply and the Model matically maintains system pressure at tion to the standards of any authorities AMD-1 Device,as well as between the preset level.The 3/32 inch(2,4 mm) having jurisdiction. Failure to do so the Model AMD-1 Device and the orifice in the Restrictor Check Valve may impair the performance of these system to pressurize. devices. limits the flow of air from the Pressure Regulator into the system to a value 2. Place a 1/2 inch(DN15),non-spring Owners are responsible for maintain- significantly less than that exhausted loaded, rubber-faced, swing-type ing their fire protection system and by the operation of a 5.6 K-factor check valve between the Model devices in proper operating condition. sprinkler. AMD-1 Device and the system to The installing contractor or sprinkler pressurize. A check valve of this manufacturer should be contacted type is provided in the air supply with any questions, trim of TYCO dry pipe valves, pre- action valves,and dry pilot trim. • Page 1 of 4 AUGUST 2015 TFP1221 TFP1221 Page 2 of 4 2" 09,6 " • (50,8 mm) (409,6 mm) 1/4"NPT I BY-PASS VALVE (NORMALLY f GAUGE � CLOSED) T TEST PORT 3-1/4' 1/2" NPT T P/N 46-047-1-004 � (82,6 mm) OUTLET S � CONNECTION r 1 (O SYSTEM) :�.II*I�IiI�i�jjIII*II.I. 8-1/2"filikkill • 1/2"NPT (215,9 mm) SIIIIM * 1.4 INLET CONNECTION LABEL .; Will (FROM COMPRESSED iu. • -� AIR SUPPLY) limn= I IIIII RESTRICTOR lT(m ��\ CHECK VALVE P/N 92-326-1-003 PRESSURE AIR SUPPLY REGULATOR STRAINER CONTROL VALVE (ADJUSTABLE) P/N 52-353-1-002 (NORMALLY OPEN) P/N 92-324-1-012 P/N 46-048-1-002 FIGURE 1 MODEL AMD-1 AUTOMATIC AIR MAINTENANCE DEVICE Setting 6. Open the Air Supply Control Valve 10. Open the control valve in the in the Model AMD-1 Device. air supply trim to the system to Procedure 7. While observing the relocated pressurize. pressure gauge, adjust the output 11. Open the Air Supply Control Valve The TYCO Model AMD-1 Automatic pressure of the Pressure Regula- in the Model AMD-1 Device. Air Maintenance Device must be tor. Pull the knob out and away 12. Open the By-Pass Valve in the • set in accordance with the following from the Pressure Regulator bodyModel AMD-1 Device. instructions: and then slowly turn the knob 1. Determine the pressure that meets clockwise, as viewed from the 13. Close the By-Pass Valve after the requirements resat m e the knob end of the Pressure Regu- system is pressurized to approxi- thet minimumto eq lator, to increase pressure, and mately 5 psi(0,4 bar)less than the counter-clockwise to decrease minimum required system pres- 2. Close the Model AMD-1 By-Pass pressure. sure determined in Step 1. Valve,and close the Model AMD-1 When decreasing pressure,the air 14. After the system pressure sta- Air Supply Control Valve. pressure must be relieved down- bilizes, note the value and corn- 3. Open the control valve in the air stream of the Pressure Regulator pare with the requirement. Re- supply trim of the system to pres- by temporarily opening the control adjust the Pressure Regulator, as surize and then reduce the system valve in the air supply trim of the required. air pressure to 0 psi. system to pressurize,assuming that 4. Close the control valve in the the system to pressurize is at 0 psi. NOTICE air supply trim of the system to After the Pressure Regulator is set, If the system was over-pressurized pressurize. push the knob in and towards the during manual fill, open a suitable 5. Remove the system pressure Pressure Regulator body to"snap" connection to the system and manu- it in a locked position. ally reduce the pressure to the desired gauge from its connection and temporarily install it in the 1/4 inch 8. Close the Air Supply Control Valve value. The Model AMD-1 Automatic Air NPT Model AMD-1 Gauge Test in the Model AMD-1 Device. Maintenance Device then automatically Port, maintains the preset system pressure. 9. Return the system air pressure The Restrictor Check Valve prevents gauge to its normal location. Re- the Pressure Regulator from bleeding CAUTION install the 1/4 inch pipe plug in the down the system pressure. Before removing the plug,make certain Model AMD-1 Gauge Test Port. In order to minimize the time for system that the piping to which the Model Apply pipe-thread sealant spar- trip in the event of a sprinkler opera- AMD-1 Gauge Test Port is connected ingly to the plug threads only. fion, set the system pressure at the is at 0 psi. Failure to do so may result minimum required value. in personal injury or property damage. CAUTION Before removing the pressure gauge, make certain that the piping to which • the Model AMD-1 Gauge Test Port is connected is at 0 psi. Failure to do so may result in personal injury or prop- erty damage. TFP122i Page 3 of 4 0 Care and Automatic sprinkler systems are rec- ommend to be inspected, tested, and maintained by a qualified Inspec- warranty tion Service in accordance with local The TYCO Model AMD-1 Automatic requirements and/or national code. For warranty terms and conditions,visit Air Maintenance Device must be main- The Model AMD-1 Device must be www.tyco-fire.com. tained and serviced in accordance with inspected quarterly in accordance with the following instructions, in addition to the following instructions: Ordering any specific requirements of the NFPA. 1. Verify that the By-Pass Valve is Any impairment must be immediatelyclosed. Procedure corrected. 2. Close the Model AMD-1 Air Supply Contact your local distributor for avail- NOTICE Control Valve and clean out the 1/4 ability. When placing an order, indi- Before closing a fire protection system inch Strainer located at the inlet cate the full product name, including main control valve for maintenance to the Restrictor Check Valve. Be description and Part Number(P/N). work on the fire protection system sure to reinstall the strainer screen and tighten the cap securely. Model AMD-1 Device that it controls, obtain permission to Specify: Model AMD-1 Automatic Air shut down the affected fire protec- 3. Open the Model AMD-1 Air Sup- Maintenance Device,P/N 52-324-2-002 tion system from the proper authori- ply Valve and verify that the control ties and notify all personnel who may valve in the air supply trim to the Replacement Parts be affected by this action. system to pressurize is open. Specify:(description),P/N(specify per It is recommended that accumulated 4. Verify that the system pressure is Figure 1) moisture be removed from air supply essentially the same as the previ- moisture filtration equipment at least ously established requirement. If quarterly. More frequent inspections not, adjust the system pressure may be necessary in particularly humid as follows: environments. a. Close the system's main con- After placing a fire protection system trol valve and open the main in service, notify the proper authori- drain valve. If the system is so ties and advise those responsible for equipped, close the Accelera- monitoring proprietary and/or central tor Control Valve. • station alarms. b. Follow Steps 1 through 14 in Responsibility lies with owners for the the Setting Procedure section. inspection,testing,and maintenance of c. Slowly open the Accelerator their fire protection system and devices Control Valve, as applicable. in compliance with this document, as well as with the applicable standards of d. Slowly open the main con- the National Fire Protection Association trol valve. After water begins (for example, NFPA 25), in addition to to flow, slowly close the main the standards of any other authorities drain valve, then completely having jurisdiction.Contact the install- open the main control valve. ing contractor or sprinkler manufac- The Model AMD-1 Automatic turer regarding any questions. Air Maintenance Device is now ready for service. • Model 1011T • A TESTANDRrIN® Sectional Floor Control Test and Drain Valve with Pressure Gauge for Systems Requiring Pressure Relief Valve Sizes: ,, 3A4u u u u n ., 1 1/4 1 1/2 2 4 taa kw 7 ,"'ns g Y :77 The AGF Model 1011T TESTANDRAIN® �provides the test and express drain functions for wet fire sprinkler systems on multi-story installations requiring pressure relief (NFPA ` 13 and NFPA 13R). The Model 1011A fea- P"" tures a Model 7000 Pressure Relief Valve ._.• with drain pipe, 31/2" Model 7500 Pressure 11, IOW Gauge and 3-Way Globe Valve. TEST ,).$> NI The Model 1011T is available in a full range of sizes (3/4" to 2") with NPT connections 1 , V (BSPT available).The Model 7000 Pressure " '`" ` t • ' it u»-s illRelief Valve (UUFM) features a flushing • 4` handle and a 175 PSI factory rating (other pressure ratings available). ' .' . �`` it' e / 1 • Complies with NFPA 13 Requirements • Compact, Single-Handle Ball Valve • Tamper-Resistant Test Orifice and Sight Glasses • 300 PSI rated. • Specifiable orifice sizes:3/a" (2.8K), 7A1s" (4.2K), 1/2" (5.6K), 17/32" (8.0K), 5/a" (11.2K, ELO), 3/4" (14.0K, ESFR), and K25 • Relieves Excess System Pressure caused by Surges or Temperature Changes • Includes Model 7500 Pressure Gauge and UUFM Model 7600 Globe Valve • Shipped with Relief Valve and Bypass Drain Ports Plugged to Expedite Pressure Testing • Locking Kit Available Repair kits are available for all TESTANDRAIN® valves. Kit includes: Adapter Gasket (1), Ball (1), Valve Seats (2), Stem Packing (1), and Stem Washer(1). Valve and orifice size must be specified when ordering. J NOTE: It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve. Standard relief valves are required to OPEN in a range of pressure between 90%and 105%of their rating.The valves are required to CLOSE at a pressure above 80%of that rating.The relief valve should be installed where it is easily accessible for maintenance.Care should be taken that the relief valve CANNOT be isolated from the system when the system is operational,A relief valve should NEVER have a shutoff valve or a plug downstream of its outlet. Reliability, Versatility, Code Compatibility SS-M1011T_V001•06/13 TESTANDRAIN is a registered trademark of AGF Manufacturing Inc. Model 1011T ssR l c OL A LISTED T ESTANDRAIN 0 Model 1011T 300 PSI Bronze Ball Valve, Model 7000 PressureAPPROVED Relief Valve, Model 7500 Pressure Gauge, and Model 7600 1/4" 3-Way Globe Valve Dimensions Model 1011T - Front View SIZE A B C D E F ', 3/4" 101/4" ni3" 113/is" 406" 63/s" 80" (256 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) (119 mm) ,,A -♦ 1" 101/4" 30" 1106" 406" 63/8" 80" F A (256 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) (119 mm) A-e-A 11/4 101/2„ 35/a" 115/16" 59/16" 71/2" 9" ro c ��}��-■ .. (263 mm) (91 mm) (51 mm) (141 mm) (192 mm) (225 mm) o"a" _ :� �n l��y��II ,�c , 11 1%2„ 111/Z" 37/8" 20" 81/4" 107/8" 911/18' T ��G (288 mm) (99 mm) (67 mm) (207 mm) (274 mm) (242 mm) 1 `1:0 :.:.i.; ::::�j,+ au 2" 110" 37/a" 25/a" 81/4" 107/8" 911/16" (288 mm) (99 mm) (67 mm) (207 mm) (274 mm) (242 mm) The Model 1011T provides the following.... From the 2013 Edition of NFPA 13 Orifice Sizes Chapter 8.16.2.4.1* Provisions shall be made to properly drain all parts of the system. 3/13", 1/46", 1/2",1/32",5/a" ELO*, Chapter 8.16.2.4.2 Drain connections, interior sectional or floor control valve(s)- 3/4" ESFR*,and K25*' &8.16.2.4.3 shall be provided with a drain connection having a minimum size as shown in Table 8.16.2.4.2. Chapter 8.16.2.4.4 Drains shall discharge outside or to a drain capable of handling theIII flow of the drain. Chapter A.8.17.4.2 (Wet Pipe System)test connection is permitted to terminate into a drain capable of accepting full flow... using an approved sight test Materials connection containing a smooth bore corrosion-resistant orifice Handle Steel giving a flow equivalent to one sprinkler... Stem Rod Brass Chapter 8.17.4.2.2 The test connection valve shall be accessible. Ball C.P. Brass Chapter 8.17.4.2.4 shall be permitted to be installed in any location... downstream of Body Bronze the waterflow alarm. Valve Seat Impregnated Teflon® Chapter 8.17.4.3.1 (Dry Pipe System)a trip test connection not less than 1" in diameter, Indicator Plate Steel terminating in a smooth bore corrosion-resistant orifice,to provide Relief Valve Bronze a flow equivalent to one sprinkler... Bypass Fittings Brass Chapter 8.17.4.3.2 The trip test connection... with a shutoff valve and plug not less Bypass Tubing Nylobraid than 1", at least one of which shall be brass. Chapter 7.1.2 -a wet pipe system shall be provided with a listed relief valve set to operate at 175 PSI or 10 PSI in excess of the maximum system pressure, whichever is greater. Chapter 8.16.1.2.3* A listed relief valve of not less than 1/2" in size shall be provided on the discharge side of the pressure-reducing valve set to operate at Approvals a pressure not exceeding rated pressure of the system. UL and ULC Listed: Chapter A.8.16.1.2.3 -consideration should be given to piping the discharge from the (EX4019&EX4533) (pressure relief)valve Chapter 8.16.1.2.2 Pressure gauges shall be installed on the inlet and outlet sides of FM Approved ^�� NYC-BSA No.720-87-SM rA1E each pressure reducing valve. Al ILL USA Patent # 4741361 and Other Patents Pending A a AGF Manufacturing Inc. Job Name: • 100 Quaker Lane,Malvern,PA 19355 Architect: FPhone:610-240-4900 Fax:610-240-4906 Engineer: www.testandrain.com Contractor: 'Available on 1 Y4"to 2"size units only•"Available on 11h"and 2"size units only ZURH® Model F100 / FlOOG Fire Hose Valve • Application Zurn Model F100/F10OG Fire Hose Valves are standpipe - `-. valves listed for use on a fire hose rack assembly,or as a fire department outlet connection. i IStandards Compliance ,z• • UL®Listed - ' ( kf, • C-UL®, ULC®Listed (2-1/2"only) , 1 ; • FM®Approved '' Material I '*' r i ., Main valve body Brass C37700 if it 4...#' kr,, 0-Rings EPDM (A70) Handwheel Aluminum A03600 212-F100 112-F100F 212-F100G Handwheel Bolt Brass C37700 FNPT x NH FNPT x FNPT Grooved x NH Handwheel Retaining washer 304 Stainless Steel Features Options Sizes: 1-1/2",2-1/2" (Suffixes can be combined) Maximum inlet pressure 300 psi 0 F - Female NPT inlet and outlet angle valve Inlet connection FNPT or Grooved 0 ST - Specified thread outlet Outlet connection Male hose 0 CH - Rough Chrome Plated (Request lead time) Outlet connection FNPT Outlet connection Special Thread (optional) B • - ( 1 A rfil 4i 1 u"re" H D -I E--- RADIUS OF SWING Dimensions&Weights(do not include pkg.) DIMENSIONS(approximate) MODEL A OPEN A CLOSED B C D E WEIGHT in. mm in. mm in. mm in. mm in. mm lbs kg 112-F100 7 3/4 195 6 3/4 169 4 100 2 50 2 1/2 63 2 3/4 68 4 2 112-F100F 7 3/4 195 6 3/4 169 4 1/8 103 2 50 2 5/8 66 2 7/8 72 4 2 212-F100 10 5/8 268 8 7/8 225 5 127 2 3/4 68 3 1/8 79 3 1/2 88 8 4 212-F100F 10 5/8 268 8 7/8 225 5 127 2 3/4 68 3 3/8 84 3 3/4 94 8 4 • 212-F100G 11 1/2 291 9 7/8 248 5 127 3 5/8 91 3 1/8 79 n/a n/a 9 4 212-F100GF 11 1/2 291 9 7/8 248 5 127 3 5/8 91 3 3/8 84 n/a n/a 9 4 Zurn Industries,LLC I Wilkins Rev.A 1747 Commerce Way,Paso Robles,CA U.S.A.93446 Ph.855-663-9876,Fax 805-238-5766 Date:7/18 In Canada I Zurn Industries Limited Document No.F100 3544 Nashua Drive,Mississauga,Ontario L4V 1L2 Ph.905-405-8272,Fax 905-405-1292 Product No.Model F100 www.zurn.com Page 1 of 1 • Fire Protection Electrical P POTTER BELLS a The Symbol of Protection PBA-AC&MBA-DC • Features • Listed for indoor and outdoor use • ,�,p •., • Outdoor use requires BBK-1 or HC-BB weatherproof back box • Indoor use mounts directly to standard 4"box • Low current draw • High dB output s • AC and DC models 1 • ag *' • DC models are motor driven,polarized,and have built in transient protection for supervised alarm circuits • Available in 6",8"and 10"sizes ® 6 ® . , APPROVED 1• 1 *ULC on MBA-DC Only Description Technical Specifications These vibrating type bells are designed for use as fire or general Dimensions 6"(150mm),8"(200mm)and 10"(250tmn) signaling devices.They have low power consumption and high decibel ratings.The unit mounts on a standard 4"(101mm)square electrical Cover Steel Finish:Red Powder Coat Enclosure Base:non-corrosive composite material box for indoor use or on a model BBK-1 or HC-BB weatherproof All parts have corrosion resistant finishes backbox for outdoor applications.Weatherproof backbox model BBK- Model BBx-1 or He-BB weatherproof backbox(optional) 1 or HC-BB,Stock No. 1500001. 24VAC Voltages Available 120VAC Notes 24VDC (10.2 to 15.6)Polarized 24VDC(20.4 to 31.2)Polarized I. Minimum dB ratings are calculated from integrated sound pressure Indoor or outdoor use(See Note 1) measurements made at Underwriters Laboratories as specified in Environmental 40°to 150°F(-40°to 66°C) Limitations UL Standard 464. UL temperature range is-30°to 150°F(-34°to (Outdoor use requires weatherproof backbox.) 66°C) AC Bells-4 No.18 AWG stranded wires Termination DC Bells-Terminal strip 2. Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels Service Use NFPA 13,72,local AHJ in an actual installation. 3. ULC only applies to MBA DC bells. *Specifications subject to change without notice. Size inches Voltage Model Stock Current Typical dB at Minimum dB at T" ' f WARNING r R N I n'(1 (mm) Number Number (Max.) 10 ft.(3m)(2) 10 ft.(3m)(I) • Y M ' ,y u _ 6(150) I2VDC MBA-6-12 1750070 .12A 85 76 • Installation must be performed by qualified personnel and in accordance with all 8(200) I2VDC MBA-8-12 1750080 .12A 90 77 national and local codes and ordinances. 10(250) I2VDC MBA-10-12 1750060 12A 92 78 • Shock hazard.Disconnect power source before servicing.Serious injury or death could result. 6(150) 24VDC MBA-6-24 1750100 .06A 87 77 • Risk of explosion.Not for use in hazardous locations.Serious injury or death 8(200) 24VDC MBA-8-24 1750110 .06A 91 79 could result. 10(250) 24VDC MBA-10-24 1750090 .06A 94 80 6(150) 24VAC PBA246 1806024* .17A 91 78 8(200) 24VAC PBA248 1808024* .17A 94 77 k 10(250) 24VAC PBA2410 1810024* .17A 94 78 In outdoor or wet installations,bell must be mounted with weatherproof backbox, 6(150) 120VAC PBA1206 1806120* .05A 92 83 BBK-1 or HC-BB. Standard electrical boxes will not provide a weatherproof al 8(200) 120VAC PBA1208 1808120* .OSA 99 enclosure.If the bell and/or assembly is exposed to moisture,it may fail or create an electrical hazard. 10(250) 120VAC PBA12010 1810120* .05A 99 86 All DC bells are polarized and have built-in transient protection. *Does not have ULC listing. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 5400776-REVZ • 11/17 PAGE IOF2 P POTTER BELLS The Symbol of Protection PBA-AC&MBA-DC • Installation The bell shall be installed in accordance with NFPA 13,72,or local AHJ.The top of the device shall be no less than 90"AFF and not less than 6"below the ceiling. 1. Remove the gong. 2. Connect wiring(see Fig.3). 3. Mount bell mechanism to backbox(bell mechanism must be mounted with the striker pointing down). 4. Reinstall the gong(be sure that the gong positioning pin,in the mechanism housing,is in the hole in the gong). 5. Test all bells for proper operation and observe that they can be heard where required(bells must be heard in all areas as designated by the authority having jurisdiction). Weatherproof Backbox Dimensions AWARNING Inches (mm) Failure to install striker down will prevent bell from ringing. MODEL BBK-1 OR HC-BB Fig 2 Bell Dimension Inches (mm) _ _ Fig J 53/4" 0 _ E ll33/8" 5" (146 mm) (86mm) (127mm) 10" • (250 mm) 8„ L �� (200 mm) 6.. 3 3/8" 15mm Ho mm) • (150 mm) (4L ) f- 4 1/4" HOB mm) 211/16" I- '�A (68 mm) (` DWGp]61 • �D Wiring Rear View Fig 3 D.C. BELLS (OBSERVE POLARITY) A.C. BELLS RED (IN) bh. RED (OUT) WHITE (IN) Aiii WHITE (OUT) FROM CONTROL PANEL ri TO NEXT BELL FROM CONTROL PANELrili OR OR ENO-OF-UNE OR ' PRECEDING BELL RESISTOR PRECEDING BELL BLACK (IN) r BLACK (Our) BUCK (IN) - ' BLACK (Our) CAUTION- CAUTION' WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. NOTES: NOTES: 1. OBSERVE POLARITY TO RING D.C. BELLS. 1. WHEN USING A.C. BELLS, TERMINATE EACH EXTRA WIRE SEPERATELY 2. RED WIRES POSITIVE (+), AFTER LAST BELL. 3. BLACK WIRES NEGATIVE (-). 2. END-OF-LINE RESISTOR IS NOT REQUIRED ON AC BELLS . • 4. EOL RESISTOR IS SUPPLIED BY FIRE ALARM CONTROL PANEL. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 5400776-REVZ • 11/17 PAGE2OF2 P POffIFIER VSR VANE TYPE WATERFLOW • - The Symbol of Protection ALARM SWITCH WITH RETARD UL,CUL and CSFM Listed,FM Approved,LPCBApproved,For CE Marked(EN12259-5)/VdS Approved model use VSR-EU Service Pressure: 450 PSI(31 BAR)-UL Flow Sensitivity Range for Signal: 4-IOGPM(15-38LPM)-UL Maximum Surge: 18 FPS(5.5 m/s) Contact Ratings: Two sets of SPDT(Form C) 10.0Amps at 125/250VAC --. 2.0 Amps at 30VDC Resistive ;43` 10 mAmps min.at 24VDC Conduit Entrances: Two knockouts provided for t/2"conduit. Individual switch compartments suitable for dissimilar voltages. 11 Environmental Specifications: • NEMA 4/IP54 Rated Enclosure suitable for indoor or outdoor use with factory installed gasket and die-cast housing when used with appropriate conduit fitting. xi • Temperature Range: 40°F-120°F,(4.5°C-49°C)-UL `# • Non-corrosive sleeve factory installed in saddle. Service Use: Automatic Sprinkler NFPA-13 Specifications subject to change without notice. One or two family dwelling NFPA-13D Ordering Information Residential occupancy up to four stories NFPA-13R Nominal Pipe Size Model Part Number National Fire Alarm Code NFPA-72 • 2" DN50 VSR-2 1144402 2 I/2" DN65 VSR-2 1/2 1144425 WARN IIV L'i+== • Installation must be performed by qualified personnel and in 3" DN80 VSR-3 1144403 accordance with all national and local codes and ordinances. 3 1/2" - VSR-3 1/2 1144435 • Shock hazard.Disconnect power source before servicing. Serious 4" DN100 VSR-4 1144404 injury or death could result. j • Risk of explosion.Not for use in hazardous locations.Serious 5" - VSR-5 1144405 injury or death could result. 6" DN150 VSR-6 1144406 8" DN200 VSR-8 1144408 CAUTION Optional: Cover Tamper Switch Kit,stock no.0090148 Waterflow switches that are monitoring wet pipe sprinkler systems shall Replaceable Components:Retard/Switch Assembly,stock no. 1029030 not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Waterflow switches used for this application may result in unintended discharges caused by surges, trapped air,or short retard times. Important: This document contains important information on the installation and operation of the VSR waterflow switches. Please read all instructions carefully before beginning installation. A copy of this document is required by NFPA 72 to be maintained on site. General Information Enclosure The Model VSR is a vane type waterflow switch for use on wet sprinkler The VSR switches and retard device are enclosed in a general purpose, systems.It is UL Listed for use on a steel pipe;schedules 5 through 40, die-cast housing. The cover is held in place with two tamper resistant sizes 2"-6"and is UL Listed and FM Approved for use on steel pipe; screws which require a special key for removal. A field installable schedules 10 through 40,sizes 2"thru 8"(50 mm thru 200 mm). LPC cover tamper switch is available as an option which may be used approved sizes are 2" thru 8" (50 mm thru 200 mm). See Ordering to indicate unauthorized removal of the cover. See bulletin number Information chart. 5401103 for installation instructions of this switch. The VSR may also be used as a sectional waterflow detector on large systems.The VSR contains two single pole,double throw,snap action switches and an adjustable, instantly recycling pneumatic retard. The S .switches are actuated when a flow of 10 GPM(38 LPM)or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 866-956-1211/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MFG.#5401146-REV M PAGE 1 OF 4 11/15 P POTTER VSR VANE TYPE WATERFLOW • e The Symbol of Protection ALARM SWITCH WITH RETARD Installation (see Fig. 1) These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they shall be installed on the top side of the pipe where they will be accessible. The device should not be installed within 6"(15 cm)of a fitting which changes the direction of the waterflow or within 24" (60 cm)of a valve or drain. NOTE:Do not leave cover off for an extended period of time. Drain the system and drill a hole in the pipe using a hole saw in a slow speed drill(see Fig. 1). Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole.Roll the vane so that it may be inserted into the hole;do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterflow.Take care not to damage the non-corrosive bushing in the saddle.The bushing should fit inside the hole in the pipe. Install the saddle strap and tighten nuts alternately to required torque (see the chart in Fig. 1).The vane must not rub the inside of the pipe or bind in any way. A CAUTION Do not trim the paddle.Failure to follow these instructions may prevent the device from operating and will void the warranty.Do not obstruct or otherwise prevent ', the trip stem of the flow switch from moving when water flows as this could damage the flow switch and prevent an alarm.If an alarm is not desired,a qualified technician should disable the alarm system. Fig. 1 I Retard Adjustment I DO NOT LEAVE COVER OFF FOR %it AN EXTENDED PERIOD OF TIME The delay can be adjusted by rotating the retard adjustment knob from '' III 0 to the max setting(60-90 seconds).The time delay should be set at ��,4 *. , the minimum required to prevent false alarms 0_\\1 111.). , I/ 10 TIGHTEN NUTS 11N1 < ���11 it t*. ALTERNATELY CAUTION \�.1:%f /� r� I 11/ Hole must be drilled perpendicular to the pipe and vertically centered ` J Refer to the Compatible Pipe/Installation Requirements chart for size. = 00 Incorrect AL ��� Correct I co MOUNT ON PIPE SO /l �. ARROW ON SADDLE d 3 / � III � POOFWTS IN TERFLODIRECTION -P-(1) u .� OF WATERFLOW Ilamm.emo_ Z m j�Iil U ROLL PADDLEIN pDAI it 50xnm f ADAPTER OPPOSITE DIRECTION OF OF WATERFLOW DIRECTION WATERFLOW `` \ (Flowing water activates 20mm tlmm MAX. device in one direction only) DN50 ONLY I� USE(2)5180162 ADAPTERS AS SHOWN ABOVE OwG.1146-11 °WON I1461F Compatible Pipe/Installation Requirements Model Nominal Pipe Nominal Pipe Pipe Wall Thickness Hole Size U-Bolt Nuts Size O.D. Lightwall Schedule 10(UL) Schedule 40(UL) BS-1387(LPC) DN(VDS) Torque inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm ft-lb n-m VSR-2 2 DN50 2.375 60.3 .065 1.651 0.109 2.77 0.154 3.91 0.142 3.6 0.091 2.3 1.25+.125/- VSR-2 1/2 2.5 - 2.875 73.0 .084 2.134 0.120 3.05 0.203 5.16 - - - - 33.0 f 2.0 .062 VSR-2 1/2 - DN65 3.000 76.1 - - - - - - 0.142 3.6 0.102 2.6 VSR-3 3 DNSO 3.500 88.9 .083 2.108 0.120 3.05 0.216 5.49 0.157 4.0 0.114 2.9 VSR-3 1/2 3.5 - 4.000 101.6 - - 0.120 3.05 0.226 5.74 - - - - 20 27 VSR-4 4 DN100 4.500 114.3 .084 2.134 0.120 3.05 0.237 6.02 0.177 4.5 0.126 3.2 2.00±.125 50.5=2.0 VSR-5 5 - 5.563 141.3 - - 0.134 3.40 0.258 6.55 - - - - • VSR-6 6 DN150 6.625 168.3 .115 2.921 0.134 3.40 0.280 7.11 0.197 5.0 0.157 4.0 VSR-8 8 DN200 8.625 219.1 - - 0.148 3.76 0.322 8.18 0.248 6.3 0.177 4.5 NOTE:For copper or plastic pipe use Model VSR-CF. PRINTED IN USA MFG.#5401146-REV M PAGE 2 OF 4 11/15 P POTTER VSR VANE TYPE WATERFLOW • The Symbol of Protection ALARM SWITCH WITH RETARD Fig.2 Fig.3 Fig.4 Switch Terminal Connections Clamping To remove knockouts:Place screwdriver at Break out thin section of cover when Plate Terminal inside edge of knockouts,not in the center wiring both switches from one conduit 111 lit i entrance. lRif 440.--... „Ai," ��►��W�r ,. `I,,L pNr6a rwn e 6 a A �T ����� �� 1� �'� �<14.1.111_,,iy.:-7,--- , ; /�Ij An uninsulated section of a single conductor should not be looped t� around the terminal and serve as two separate connections. The °`""""' ,� � wire must be severed,thereby providing supervision of the NOTICE — ' connection in the event that the wire become dislodged from under J the terminal. Failure to sever the wire may render the device Do not drill into the base as this creates I ./� BVG.NT6-13 inoperable risking severe property damage and loss of life. metal shavings which can create .0 Do not strip wire beyond 3/8"of length or expose an uninsulated electrical hazards and damage the conductor beyond the edge of the terminal block.When using device.Drilling voids the warranty. stranded wire,capture all strands under the clamping plate. CONNECTOR Fig.5 Typical Electrical Connections NEUTRAL FROM BELL BREAKER NEUTRAL FROM BELL G 'ri.::: i BREAKER p .,; 'o •lam::.. Notes: UNE FROM BREAKER O- EOl(End 01 Line Resistor) • 1. The Model VSR has two switches,one can be used to operate a central : station,proprietary or remote signaling unit,while the other contact Ill _ is used to operate a local audible or visual annunciator. 2. For supervised circuits,see"Switch Terminal Connections" I�_r` �-111I III lII drawing and warning note(Fig.4). ire NOTE. ocm When netting to a UL Listed control panel use the panel's f resister vaWefor circuit supervision. _1♦ p. -. l O j. I'. Testing The frequency of inspection and testing for the Model VSR and its associated protective monitoring system shall be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction(manufacturer recommends quarterly or more frequently). If provided,the inspector's test valve shall always be used for test purposes.If there are no provisions for testing the operation of the flow detection device on the system,application of the VSR is not recommended or advisable. A minimum flow of 10 GPM(38 LPM)is required to activate this device. NOTICE Advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. Fig.6 Mounting Dimensions 5.56 in Fig.7 3.50 in (14I 2 mm) (89.0 mm) 2.00 in _11. __ GREEN GROUND 2.34 in I i SCREWS (59.4 mm) men) II �.'RN;'487.11'P� PI EDIA. WI I�,��,U-BOLT NUT +5.25 in �� i U-BOLT WASHER we.�`ID (+133.4mm) /Dl_s� 'Intl ���. ----., PIPE SADDLE .. PIPE 1.1 , ©1 I I "r PLASTIC PADDLEII RA I �• �1t� ,I,1 a ronwu U-BOLT NOMINAL PIPE DIA.+1.75 in(+44.5 MM)FOR ON 50-ON 65 2-2.5 in —7:— Ir NOMINAL PIPE DIA.+2.125 in(+54.0 MM)FOR DN 80-DN 200 3-8 in DWG nae-ts PRINTED IN USA MFG.#5401146-REV M PAGE 3 OF 4 11/15 SR . POTTER VANE TYPE E WATERFLOW • The Symbol of Protection ALARM SWITCH WITH RETARD Maintenance Inspect detectors monthly. If leaks are found,replace the detector. The VSR waterflow switch shouldprovide years of trouble-free service. YP The retard and switch assembly are easily field replaceable. In the unlikely event that either component does not perform properly,please order replacement retard switch assembly stock#1029030(see Fig. 8).There is no maintenance required,only periodic testing and inspection. Retard/Switch Assembly Replacement(See Fig.8) NOTICE The Retard/Switch Assembly is field-replaceable without draining the system or removing the waterfiow switch from the pipe 1. Make sure the fire alarm zone or circuit connected to the waterflow switch is bypassed or otherwise taken out of service. 2. Disconnect the power source for local bell(if applicable). 3. Identify and remove all wires from the waterflow switch. 4. Remove the(2)mounting screws holding retard/switch assembly to the base.Do not remove the(2)retard housing screws. 5. Remove the retard assembly by lifting it straight up over the tripstem. 6. Install the new retard assembly.Make sure the locating pins on the retard/switch assembly fit into the locating pin bosses on the base. 7. Re-install the(2)original mounting screws. 8. Reconnect all wires.Perform a flow test and place the system back in service. Fig 8 REMOVE(2)ORIGINAL MOUNTING SCREWS HOLDING RETARD/SWITCH ASSEMBLY TO BASE BREAKOUTTHINSECTIONOF COVER WHEN WIRING BOTH SWITCHES FROM ONE CONDUIT ENTRANCE. (2)ORIGINAL MOUNTING I / SCREWS RETAD/SWITCH ASSEMBLY I /_ • 1I- I` A N. tiron n� �( •1 r Srr `15, _ F % III (2)LOCATING PINS�� •J (2)LOCATING PIN\ ' DO NOT REMOVE I i{ 1 - BOSSES IN BASE (2)RETARD HOUSING I p i—, i i—� scaEws 0111 IIL4 " ►` �� 11111 AIM —_ IIv rr hir BASE'' .■. "air_ 144 Pow ,�►� DWG#1146-10 Removal of Waterflow Switch • To prevent accidental water damage,all control valves should be shut tight and the system completely drained before waterflow detectors are removed or replaced. • Turn off electrical power to the detector,then disconnect wiring. • Loosen nuts and remove U-bolts. • Gently lift the saddle far enough to get your fingers under it. With your fingers,roll the vane so it will fit through the hole while continuing • to lift the waterfiow detector saddle. • Lift detector clear of pipe. PRINTED IN USA MFG.R5401146-REV M PAGE 4 OF 4 11/15 P POTTER PS10 SERIES • 0 The Symbol of Protection PRESSURE SWITCH UL, cUL, and CSFM Listed, FM and LPC Approved, NYMEA Accepted,CE Marked Dimensions:3.78"(9,6cm)W x 3.20"(8,1cm)D x 4.22"(10,7cm)H t,i?OTTER Conduit Entrance:Two knockouts provided for 1/2"conduit. Individual ""b",,P ., switch compartments and ground screws suitable for m tow,.Mm»o P P810-4 Nd°""""°' (E dissimilar voltages. Enclosure: Cover-Die-cast with textured red powdercoat finish,single cover screw and rain lip. Base-Die-cast Pressure Connection:Nylon 1/2"NPT Male Factory Adjustment: 4-8 PSI(0,27-0,55 BAR) Differential: 2 PSI(0,13 BAR)typical Maximum System Pressure: 300 PSI(20,68 BAR) Switch Contacts: SPDT(Form C) 10.1 Amps at 125/250VAC,2.0 Amps at 30VDC Ordering Information One SPDT in PS10-1,Two SPDT in PSI 0-2 Model Description Stock No. Environmental Specifications: PS10-1 Pressure switch with one set 1340103 NEMA 4/IP66 Rated Enclosure-indoor or outdoor when used SPDT contacts with NEMA 4 conduit fittings. PS10-2 Pressure switch with two sets 1340104 Temperature range:-40°F to 140°F(-40°C to 60°C) SPDT contacts Service Use: Hex Key 5250062 Automatic Sprinkler NFPA-13 Cover Tamper Switch Kit 0090200 One or two family dwelling NFPA-13D Tamper Residential Occupancy up to four stories NFPA-13R Cover incorporates tamper resistant fastener that requires a special key for National Fire Alarm Code NFPA-72 • removal.One key is supplied with each device. For optional cover tamper switch kit,order Stock No.0090200. See bulletin#5401200 PSCTSK. Installation The Potter PS10 Series Pressure Actuated Switches are designed for the into alarm port piping on the input side of retard chamber and electrically detection of a waterflow condition in automatic fire sprinkler systems of connect PS I0 to control unit that provides a retard to compensate for surges. particular designs such as wet pipe systems with alarm check valves,dry Insure that no unsupervised shut-off valves are present between the alarm pipe,preaction, or deluge valves. The PS I O is also suitable to provide a check valve and PS10. low pressure supervisory signal;adjustable between 4 and 15 psi(0,27 and Method 2: When using the PSI O for local bell application or with a control 1,03 BAR). that does not provide a retard feature-the PS 10 must be installed on the alarm 1.Apply Teflon tape to the threaded male connection on the device. outlet side of the retard chamber of the sprinkler system. (Do not use pipe dope) Testing.- Accomplished by opening the inspector's end-of-line test valve. 2.Device should be mounted in the upright position(threaded connection down). Allow time to compensate for system or control retard. 3.Tighten the device using a wrench on the flats on the device. Note: Method 2 is not applicable for remote station service use,if there is an Wiring Instructions unsupervised shut-off valve between the alarm check valve and the PS 10. 1.Remove the tamper resistant screw with the special key provided. Wet System With Excess Pressure 2.Carefully place a screwdriver on the edge of the knockout and Connect PS 10 into alarm port piping extending from alarm check valve. sharply apply a force sufficient to dislodge the knockout plug.See Fig 9 Retard provisions are not required. Insure that no unsupervised shut-off 3.Run wires through an approved conduit connector and affix the connector valves are present between the alarm check valve and the PS 10. to the device. Testing: Accomplished by opening the water by-pass test valve or the 4.Connect the wires to the appropriate terminal connections for the inspector's end-of-line test valve. When using end-of-line test,allow time service intended.See Figures 2,4,5,and 6.See Fig 7 for two switch,one for excess pressure to bleed off conduit wiring. Dry System Testing Connect PS10 into alarm port piping that extends from the intermediate The operation of the pressure alarm switch should be tested upon completion chamber of the alarm check valve. Install on the outlet side of the in-line of installation and periodically thereafter in accordance with the applicable check valve of the alarm port piping. Insure that no unsupervised shut-off NFPA codes and standards and/or the authority having jurisdiction valves are present between the alarm check valve and the PS 10. (manufacturer recommends quarterly or more frequently). Testing:Accomplished by opening the water by-pass test valve. Wet System Note: The above tests may also activate any other circuit closer or water • Method!: When using PSI0 and control unit with retard-connect PS10 motor gongs that are present on the system. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 866-956-0988/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MFG.#5400928-REV D-I PAGE 1 OF 3 12/10 1 P POTTER PS10 SERIES ® The Symbol of Protection PRESSURE SWITCH • Dimensions Switch Clamping Plate Terminal Fig. 1 Fig.2 (tf_7#, oo 1 SGCR ROUN = co �� p1 It'.hill1: I 2.87 1 `..! Y� ADJUSTMENT laiRai f' ® [72.97] 4.22 KNOB '�- I ► 1..I I— ■G1 t [107.19] 1--�/71 +�__�` GpSIG °woo nIa 1/2"NPT 0 [6287] [4064] , e,'.:- AWARNING 3.78 . 3.20 An uninsulated section of a single conductor [95.89] r [81.28] should not be looped around the terminal and serve as two separate connections. The wire NOTE.'To prevent leakage,apply Teflon tape sealant to male threads only, must be severed,thereby providing supervision of the connection in the event that the wire DWG#930.i becomes dislodged from under the terminal. Typical Sprinkler Applications Fig.3 WET SYSTEM WITH WET SYSTEM WITHOUT DRY SYSTEM EXCESS PRESSURE EXCESS PRESSURE PSIU WATER WATER MO P510 WATER _ MOTOR MOTOR MOTOR III GONG GONG GONG REVS AftDRY CHECK RBVS SY WET WET REVS SYSTEM VALVE STEM " SYSTEM A A ALARM ALARM. I V A CHECK VALVE CHECK RETARD VALVE .. VALVE I. WATER WATER WATER OS&Y • BY.PASS OS&Y ♦ BY.PASS OS&Y • BY-PASS VALVE A VALVE VALVE A VALVE VALVE A VALVE DWG.#923-2AA A CAUTION Closing of any shutoff valves between the alarm check valve and the PS I O will render the PS 10 inoperative.To comply with NFPA-72 any such valve shall be electrically supervised with a supervisory switch such as Potter Model RBVS. Low Pressure Signal Connection Waterflow Signal Connection Local Bell For Waterflow Connection Fig.4 Fig.5 Fig.6 TO FIRS ALARM PANEL TO FIRE ALARM PANEL NEGATIVE DC OR NEUTRAL AC 4111 OR HOT AC LINE LOAD AII -■�.-- __�—_ OR HOT AC Is- . 'PA1M1..1M1 fr'iLilira1irmil 1 ® ® fli Till PIrm 9-7-1 ® ® II® IO ' p (DI fi 'T1 ® IO O ® I,® p p ® - =-�1_1i owcxne.i owcpna-s owcwvu3 PRINTED IN USA MFG.#5400928-REV D-1 PAGE 2 OF 3 12/10 P POTTER PS10 SERIES . The Symbol of Protection PRESSURE SWITCH One Conduit Wiring Switch Operation Removing Knockouts Fig.7 Fig.8 Fig.9 Break out thin section of divider to provide path for wires Terminal W/PRESSURE APPLIED C:Common when wiring both switches from one conduit entrance. 1: Closed when installed under normal system t.,,,..,,lel +�—_. pressure. ! 1"�'1",- 1 ®® 2: Open when installed under normal system .0°o� pressure.Closes onilllik ,��i ' ,,;i, low pressure Use for ` - , ,'1�./;'/ Pdrop. su erv2sron. / I' 00�' Terminal W/O PRESSURE APPLIED �� �-�+ 1: Open with no pressure ri' supplied.Closes upon c detection of pressure. ���� � r�, Use for waterflow \� indication. b PA cx 928-0 2: Closed with no c 2 DWG#928-5 pressure applied. nwG8928-6 AWARNING.... A CAUTION •Installation must be performed by qualified personnel and in •Do not tighten by grasping the switch enclosure.Use wrenching accordance with all national and local codes and ordinances. flats on the bushing only.Failure to install properly could damage •Shock hazard.Disconnect power source before servicing. the switch and cause improper operation resulting in damage to Serious injury or death could result. equipment and property. *Read all instructions carefully and understand them before •To seal threads,apply Teflon tape to male threads only. Using • starting installation.Save instructions for future use.Failure to joint compounds or cement can obstruct the pressure port inlet read and understand instructions could result in improper and result in improper device operation and damage to equipment. operation of device resulting in serious injury or death. •Do not over tighten the device,standard piping practices apply. •Risk of explosion.Not for use is hazardous locations.Serious injury or death could result. Engineer/Architect Specifications Pressure Type Waterflow Switch Pressure type waterflow switches;shall be a Model PSIO as Pressure switch shall have one or two form C contacts,switch contact manufactured by Potter Electric Signal Company,St Louis MO., rating 10.1 Amps at 125/250 VAC,2.0 Amps at 30 VDC. and shall be installed on the fire sprinkler system as shown and or Pressure type waterflow switches shall have two conduit entrances specified herein. one for each individual switch compartment to facilitate the use of Switches shall be provided with a r/z"NPT male pressure connection dissimilar voltages for each individual switch. and shall be connected to the alarm port outlet of;Wet Pipe Alarm The cover of the pressure type waterflow switch shall be Zinc die-cast Valves,Dry Pipe Valves,Pre-Action Valves,or Deluge Valves.The with rain lip and shall attach with one tamper resistant screw.The pressure switch shall be actuated when the alarm line pressure reaches Pressure type waterflow switch shall be suitable for indoor or outdoor 4-8 PSI(0,27-0,55 BAR). service with a NEMA 4/IP66 rating. Pressure type waterflow switches shall have a maximum service The pressure type waterflow switch shall be UL Ulc and CSFM listed, pressure rating of 300 PSI(20,68 BAR)and shall be factory adjusted FM and LPC approved and NYMEA accepted. to operate on a pressure increase of 4-8 PSI(0,27-0,55 BAR) • PRINTED IN USA MFG.#5400928-REV D-1 PAGE 3 OF 3 12/10 P POTTER PS40 SERIES • The Symbol of Protection SUPERVISORY PRESSURE SWITCH UL, cUL, and CSFM Listed, FM and LPC Approved, NYMEA Accepted,CE Marked Dimensions:3.78"(9,6cm)W x 3.20"(8,lcm)D x 4.22"(10,7cm)H Conduit Entrance: Two knockouts provided for 1/2"conduit.Individual switch compartments and ground screw suitable for dissimilar voltages 0 porrER Enclosure: Cover-Die-cast with textured red powdercoat finish,single C me Symms ,M.n rtc.. cover screw and rain lip. Base-Die-cast &sN�UNC 1:&CAM Numbnr,N IPCB, Pressure Connection:Nylon 1/2"NPT male caw PS40—2 usm ""' SUPERVISORY Factory Adjustment: PS40-1 operates on decrease at 30 PSI(2,1 BAR) PS40-2 operates in increase at 50 PSI(3,5 BAR) and on decrease at 30 PSI(2,1 BAR) Pressure Range: 10-60 PSI(,7-4,1 BAR) Differential: Typical 1 lb.at 10 PSI(,07 at,7 BAR) 4 lbs at 60 PSI(,28 at 4,1 BAR) Maximum System Pressure:300 PSI(20,68 BAR) Switch Contacts: SPDT(Form C) 10.1 Amps at 125/250VAC,2.0 Amps at 30VDC One SPDT in PS40-1,Two SPDT in PS40-2 Environmental Specifications: NEMA 4/IP66 Rated Enclosure-indoor or outdoor when used with NEMA 4 conduit fittings. Temperature range:-40°F to 140°F(-40°C to 60°C) Tamper: Cover incorporates tamper resistant fastener that requires a Ordering Information special key for removal. One key is supplied with each device. For optional cover tamper switch kit,order Stock No.0090200. • Model Description Stock No. See bulletin#5401200 PSCTSK. PS40-1 Pressure switch with one set SPDT contacts 1340403 Service Use: PS40-2 Pressure switch with two sets SPDT contacts 1340404 Automatic Sprinkler NFPA-13 Hex Key 5250062 One or two family dwelling NFPA-13D Cover Tamper Switch Kit 0090200 Residential Occupancy up to four stories NFPA-13R BVL Bleeder valve 1000018 National Fire Alarm Code NFPA-72 Installation The Potter PS40 Series Supervisory Pressure Actuated Switches are designed 4. Connect the wires to the appropriate terminal connections for the primarily to detect an increase and/or decrease from normal system pressure service intended. See Figures 2,4,5,6,and 8 in automatic fire sprinkler systems. Typical applications are: Dry pipe Adjustment And Testing systems,pre-action air/nitrogen supervision,pressure tanks, air supplies, The operation of the pressure supervisory switch should be tested upon and water supplies. The PS40 switch is factory set for 40 PSI(2,8 BAR) normal system pressure. The switch marked with the word LOW is set to completion of installation and periodically thereafter in accordance with operate at a pressure decrease of 10 PSI(,7 BAR)at 30 PSI(2,1 BAR). The the applicable NFPA codes and standards and/or the authority having jurisd switch marked with the word HIGH is set to operate at a pressure increase Note: ction(manufacturer recommends quarterly or more frequently). of 10 PSI(,7 BAR)at 50 PSI(3,5 BAR). See section heading Adjustments Note: Testing the PS40 may activate other system connected devices. and Testing if other than factory set point is required. The use of a Potter BVL(see product bulletin 8900067 for details)is recommended to facilitate setting and testing of the PS40 pressure switch. 1. Connect the PS40 to the system side of any shutoff or check valve. 2. Apply Teflon tape to the threaded male connection on the device. When a BVL(bleeder valve)is used,the pressure to the switch can be (Do not use pipe dope) isolated and bled from the exhaust port on the BVL without effecting the supervisory pressure of the entire system. See Fig.3 3. Device should be mounted in the upright position. (Threaded connection down) The operation point of the PS40 Pressure Switch can be adjusted to any 4. Tighten the device using a wrench on the flats on the device. point between 10 and 60 PSI(0,7-4,11 BAR)by turning the adjustment knob(s)clockwise to raise the actuation point and counter clockwise to Wiring Instructions lower the actuation point. In the case of the PS40-2,both switches operate 1. Remove the tamper resistant screw with the special key provided. independent of each other. Each switch may be independently adjusted to 2. Carefully place a screwdriver on the edge of the knockout and sharply actuate at any point acrosss the switch adjustment range. Initial adjustment apply a force sufficient to dislodge the knockout plug. See Fig.9 can be made with a visual reference from the top of the adjustment knob 3. Run wires through an approved conduit connector and affix the across to the printed scale on the switch bracket. Final adjustments should connector to the device. A NEMA-4 rated conduit fitting is be verified with a pressure gauge. • required for outdoor use. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 866-956-0988/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MFG.#5400930-REV E PAGE I OF 3 09/12 P POTTER PS40 SERIES The Symbol of Protection SUPERVISORY PRESSURE SWITCH • Dimensions Switch Clamping Plate Terminal Fig. I Fig.2 o ��G (�_.I o o f '. GROUNn `� O (�= �1 2.87 ■I 111 SCREWS 1 RIG ADJUSTMENT 1 LL W [72.97] � o KNOB Prl' 4.22 L LTTia + I^�= �_� [107.19J _I — 1- 0 0 Mr / 1/2"NPT + cae HMO 923-3 2.48 1.60 O� 'l 162.87] 1 [40.64] 378 t 3.20 y __............ [95.89] [81.28] NOTE:To prevent leakage.apply Teflon tape sealant to male threads only. An uninsulated section of a single conductor oWcn 930-i should not be looped around the terminal and serve as two separate connections. The wire must be severed,thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. Typical Sprinkler Applications Fig.3 P540 SUPERVISORY PRESSURE SWITCH A CAUTION • s S IR HUT-OFF Pots Closing of any shutoff valves between the alarm VALVE BLEEDER ALARM • check valve and the PS 10 will render the PSIO y TESTCHECK A VALVE SWITCH inoperative.To comply with IBC,IFC,and VALVE EVL P P Y WATER NFPA-l3,any such valve shall be electrically GONGR supervised with a supervisory switch such as CHECK REVS Potter Model RBVS. DRY PIPE VALVE VALVE WATER DWG.k924-IA OS&Y BY-PASS VALVE A TEST VALVE Typical Connections Fig.4 WITH NORMAL SYSTEM PRES- PS40-I PS40-2 SURE APPLIED LOW-TERMINAL 2 CLOSES ON PRESSURE DROP. TO FIRE ALARM PANEL INIIIIIIIMMIM II HIGH ©I�I" I AIR COM ME Elli COM n, i ........ coM 0© WITH NORMAL SYSTEM �dd� LOW PRESSURE APPLIED HIGH AIR TO FIRE E\ o ■ W ap -TERMINAL I WILL CLOSE ALARM IVAMIIlk71 ON PRESSURE INCREASE. PANEL rif • EOLR DWG#930-2 PRINTED IN USA MFG.#5400930-REV E PAGE 2 OF 3 09/12 P POTTER PS40 SERIES tThe Symbol of Protection SUPERVISORY PRESSURE SWITCH Low Pressure Signal Connection High Pressure Signal Connection One Conduit Wiring Fig.5 Fig.6 Fig.7 TO FIRE ALARM PANEL TO FIRE ALARM PANEL Break out thin section of divider to provide path for wires try when wiring both switches from one conduit entrance. ..•�■ice �. ma � <<, ,►•t;P'+; 0° �° DD 10 D O ® IT1 ®J 101..7., �/ �/ - O '�Illl. . DW1.993tl3 M V aRG99$81 I DWCX 9284 Changing Pressure Removing Knockouts (With normal system pressure) Fig.9 Fig.8 Terminal LOW PRESSURE SWITCH C:Common 1: Closed when installed PIP 1 under normal system c pressure. 2: Open when installed ill under normal system ,str I'I p pressure.Closes on c i a • �� ��/ pressure drop.Use for 'A ����•" 11111 low air signal. ''lb"Terminal HIGH PRESSURE SWITCHVe ����l: Open woes instated iI ® �� under normal system * pressure.Closes on i j�i 1/1 / j increase in pressure. \� Use for high air signal. I \u 2: Closed under normal system pressure. c ' 2 DWG#928-5 DWO#930-3 Engineer/Architect Specifications Pressure Type Waterfiow Switch - Pressure type supervisory switches;shall be a Model PS40 as manufactured by f(l R n I I N G Potter Electric Signal Company,St.Louis,MO.,and shall be installed on the fire 1'l t !1 Y el la -Installation must be performed by qualified personnel and in accordance with all sprinkler system as shown and or specified herein. national and local codes and ordinances. Switches shall be provided with a 1/2'NPT male pressure connection to be •Shock hazard.Disconnect power source before servicing.Serious injury or death connected into the air supply line on the system side of any shut-off valve. A could result. Model BVL bleeder valve as supplied by Potter Electric Signal Company of St. •Read all instructions carefully and understand them before starting installation. Louis,MO.,or equivalent shall be connected in line with the PS40 to provide a Save instructions for future use. Failure to read and understand instructions could means of testing the operation of the supervisory switch.(See Fig.3) result in improper operation of device resulting in serious injury or death. •Risk of explosion.Not for use is hazardous locations.Serious injury or death could result. The switch unit shall contain SPDT(Form C) switch(es). One switch shall be set to operate at a pressure decrease of 10 PSI(0,7 BAR)from normal. If two switches are provided,the second switch shall be set to operate at a pressure a CAUTION increase of 10 PSI(0,7 BAR)from normal. Switch contacts shall be rated at 10.1 Amps at 125/250VAC and 2.0 Amps at -Do not tighten by grasping the switch enclosure. Use wrenching fiats on the bushing 30VDC. The units shall have a maximum pressure rating of 300 PSI(20,68 BAR) only. Failure to install properly could damage the switch and cause improper operation and shall be adjustable from 10 to 60 PSI(0,7 to 4,1 BAR). resulting in damage to equipment and property. Pressure switches shall have two conduit entrances,one for each individual switch •To seal threads,apply Teflon tape to male threads only. Using joint compounds or compartment to facilitate the use of dissimilar voltages for each individual switch. cement can obstruct the pressure port inlet and result in improper device operation and damage to equipment. The cover of the pressure switch shall be zinc die-cast with rain lip and shall attach III notover tighten thedevice,standard piping practices apply. with one tamper resistant screw. The pressure switch shall be suitable for indoor or •Do nott apply any lubricant to any component of the pressure switch. outdoor service with a NEMA-4/IP66 rating. The pressure switch shall be UL,ULC,and CSFM listed,FM and LPC approved and NYMEA accepted. PRINTED IN USA MFG.95400930-REV E PAGE 3 OF 3 09/12 • 1 I'm also available In aye�BASEPLA L_ UNIT o - �aa ® �z � IIII �- � IIIII: iII��,I IIpP_ - i guiI � -. , . lh Iflr._ , . COMPRESSORS r. ., v°) -,,,-' : 1. Y" xY " w K 3 '. 4544 : % y . ash,"s .4.4: MfU...., fi ul} R - .fir 2 A n �. fi %fi r- ^i y kti '- ' --!;; "" *,44,,e PRODUCT NUMBERING SYSTEM S300 H — SD 1 — 115 .„i 5 ! rr ills i„itr >< ,y. a :wl,.... r t,i • ..3 ��i19ll�r!�!31 Ur � - ,� , HO 3SO U 3Baseptate H =,"•Ypu1 .1:Single Phase tt,wn� P.Preeired Power Cab1/5 , . k� � . SYSTEM CAPACITY H Horizontal Tank SO.Standard Duty 3 Three Phase napmmi S:PreeiredMagnetioShder e 4 ,, 323 263 2622 Y Y nc Ss cav 5bo U:3040psi Pressure Shiloh ::?.C. p n;1 .� SYSTEM 06 `w xweapn P51 CAPACITY �� �x ' IN GALLONS 1360 xxP SY' 1760 rv- 6 $ ' 1p816 .rsi *Greyed out opllans do not apply to this Unit SPECS: 1 ! £ :3' '630011-SD 1-t IS is a stocked item HP 1.5 K� t» -er IirAW-,14, 12 k - 1a166,A SYSTEM CAPACITY 40 PSI 312 GALLONS INCLUDES: �'-', SINGLE PHASE THREE PHASE ANKURAI M a CZ 20 PSI 672GALLONS 16 s ;:ke65y 1OP511422GALLONS u. V - 115 17.4 1.0 208 4.5 1.5 a "FULLSYNTHETICOIL q,s ,. r�, „,,, ' 1�pRkp •, _ 208 8.8 1.0 230 4.2 1.5 tWS,SULEMURM7 NWR 0. OPSI 20 672 ` GEOl1 S G S 230 8.7 1.0 460 2.13 1.5 PECIEIL D R30 40PS1 D6 CFM i3•98@jQPSI 1 124 1551 x ADDITIONAL SPECIAL ORDER OPTIONS ;H 3" , o -3 Phase Starter GP CIALORDE 1. 23ov 28 466 -Power Cord Baseplate Mount S Fondle E, y',3' 43i, I x � •DON'T FORGET YOUR INSTALLATION KIT! TANKSIZE 3 GALLON HORIZONTAL 34,, TS ' . f.. ; PST ' 1, 36 351 DIMENSIONS 2711xll"x22"HORIZONTAL 38� ' , 1�. C Tne Advantage _ 380 WEST 1ST STREET,DRESSER.WI 54009//800.762.2247//651.4613440//W WW.DAIREINGC OM -etas., t 31-1530 Terrace Glen: Exposed Areas and Non-Public Spaces Bulletin 036 January 2020 Model KFR56 Series Sprinklers . Ileilbit, Quick-response, Standard Spray Fusible Link Sprinklers K5.6(80 metric) cULus Listed, FM Approved,VdS Approved, CE Certified Product Description . Model KFR56 series sprinklers are standard spray, quick- ;ea response sprinklers with a fusible link operating element. The COI w sprinklers are cULus Listed, FM Approved, VdS Approved, i i, 1 &. >>_ and CE Certified. See Table C for available finishes.All KFR56 i x Aril ;a sprinklers have a nominal K-factor of 5.6(80 metric). ti ►,+< Model KFR56 series sprinklers are available in Ordinary =* 10 (165°F [74°C]) or Intermediate (212°F [100°C]) temperature Model KFR56 Pendent .. classification. Model KFR56 Pendent sprinklers are available ��X .. .,a _ with Model F1, Model F2,or Model FP recessed escutcheons. Application Model KFR56 series sprinklers are listed and approved 40 for installation in accordance with NFPA 13 and FM Loss y4; ; Prevention Data Sheets. Follow requirements of NFPA 13 for Quick-response Standard Spray Sprinklers when installing Model KFR56 series sprinklers. FM Approvals classifies Model KFR56 sprinklers as K5.6 QR Non-storage and K5.6 OR In-rack Model CCP Model KFR56 HSW Storage sprinklers. • Installation Model KFR56 series sprinklers must be installed in accordance Recommended installation torque is 14-20 ft-lbs (19—27 N-m). with the requirements of NFPA 13 or FM Property Loss Do not tighten sprinklers over the maximum recommended Prevention Data Sheets.The Model F1,F2,and FP escutcheons torque. Exceeding the maximum recommended torque may are the only recessed escutcheons listed and approved for use cause leakage or impairment of the sprinklers. with Model KFR56 Pendent sprinklers. The use of any other recessed escutcheon will void all approvals and warranties. Do Listings &Approvals not install Model FP escutcheons in ceilings that are positively pressurized with respect to the occupied space below. Listed by Underwriters Laboratories, Inc. and UL Certified for Use only the Model W2 sprinkler wrench for installing Model Canada(cULus) • KFR56 series pendent, upright, and horizontal sidewall Sprinklers,Automatic and Open(VNIV) sprinklers, and use only the Model W1 wrench for installing FM Approved(FM) Model KFR56 series recessed pendent, conical concealed • K5.6 QR Non-storage pendent (CCP), and recessed horizontal sidewall sprinklers. K5.6 QR In-rack Storage The use of wrenches other than those specified may damage these sprinklers. VdS Approved and CE Certified to EN12259 Model KFR Series Sprinkler Summary Table A Max. Working Sprinkler Sprinkler Model Orientation Listing or Approval Pressure Identification psi(bar) Number(SIN) KFR56 Pendent Pendent cULus 250(17.2) RA3614 FM,VdS,CE 175(12) KFR56 Upright Upright cULus 250(17.2) RA3624 KFR56 HSW HSW KFR56 Upright Intermediate FM,VdS,CE 175(12) cULus 250(17.2) RA3634 FM,VdS,CE 175(12) www.rel iablesprinkler.com Model KFR56 Pendent sprinkler SIN RA3614 Technical Specifications Sprinkler Finishes IIIStyle:Pendent, Recessed Pendent,or Conical (See Table C) Concealed Pendent Sensitivity Threads: 1/2"NPT or IS07-1R1/2 Quick-response Nominal K-Factor.5.6(80 metric) Max.Working Pressure: Temperature Ratings cULus:250 psi(17.2 bar) 165°F(74°C) FM,VdS,CE: 175 psi(12 bar) 212°F(100°C) Material Specifications Recessed Escutcheons/Cover Plates Thermal Sensor.Beryllium Nickel Model F1 escutcheon(cULus only) - 1 ki l Strut and Lever:Stainless Steel Model F2 escutcheon Roto-clip:Stainless Steel Model FP escutcheon(cULus only) Sprinkler Frame:Brass Alloy Model CCP cover plate(cULus only) Cap:Bronze Alloy Sealing Washer.Nickel with PTFE Guards/Water Shields Load Screw:Copper Alloy F-7 Guard(cULus) Deflector:Brass Alloy F-1 Guard(FM) F-8 Guard/Water Shield(cULus) Sprinkler Wrenches F-5 Guard/Water Shield(FM) Model W2(pendent) S-1 Water Shield(cULus,FM) Model W1 (recessed) Model J(with guard installed) Listings and Approvals cULus Listed FM Approved VdS Approved CE Certificate of constancy of performance 0786-CPR40313 Model KFR56 Pendent Sprinkler Components and Dimensions Figure 1 3-1/4" [83mm] • FRAME WRENCH FLATS r 0 n tlt� 1 SEALING ASSEMBLY rem 2 1/4" •I ]11 riN ri 1 �r--r� (57 mm) `t .1, ll FUSIBLE LINK 1i fly COMPRESSION SCREW n Li DEFLECTOR 1" Shown with Optional S-1 Water y (24 mm) Shield(Ordered Separately) i Bulletin 036 Reliable' Page 2 of 7 January 2020 www.reliablesprinkler.com Model KFR56 Upright Sprinkler SIN RA3624 Technical Specifications Listings and Approvals • Style:Upright cULus Listed Threads:1/2"NPT or ISO7-1 R1/2 FM Approved Nominal K-Factor.5.6(80 metric) VdS Approved Max.Working Pressure: CE Certificate of constancy of performance cULus:250 psi(17.2 bar) 0786-CPR40314 ,, FM,VdS,CE: 175 psi(12 bar) Sprinkler Finishes .. ,", ,;•,, Material Specifications (See Table C) 0 4 Thermal Sensor:Beryllium Nickel - a Strut and Lever:Stainless Steel Sensitivity Roto-clip:Stainless Steel Quick-response Sprinkler Frame:Brass Alloy Temperature Ratings 6 Cap:Bronze Alloy 165°F(74°C) Sealing Washer:Nickel with PTFE 212°F(100°C) Load Screw:Copper Alloy Deflector.Brass Alloy Guards/Water Shields Sprinkler F-1 Guard(cULus,FM) p nkler Wrench `y Model W2 F-3 Guard/Water Shield(cULus,FM) Model J(with guard installed) Factory Installed Shield(cULus,FM) Model KFR56 Upright Sprinkler Components and Dimensions Figure 2 3-1/4"(83mm) 1 5/16" • -- (33 mm) DEFLECTOR pi COMPRESSION SCREW , 11 FUSIBLE LINK p (5 27 1Im/4„ �� ' i' SEALING ASSEMBLY � `� ) ��1i -- WRENCH FLATS 11==1 FRAME Shown with Optional Factory Installed Water Shield (KFR56 Intermediate Upright) • Bulletin 036 Page 3 of 7 January 2020 Rel'labl www.reliablesprinkler.com Model KFR56 HSW Horizontal Sidewall Sprinkler SIN RA3634 Technical Specifications Listings and Approvals • Style:HSW or Recessed HSW cULus Listed Threads:1/2"NPT or IS07-1R1/2 FM Approved Nominal K-Factor.5.6(80 metric) VdS Approved Max.Working Pressure: CE Certificate of constancy of performance cULus:250 psi(17.2 bar) 0786-CPR40312 FM,VdS,CE: 175 psi(12 bar) Sprinkler Finishes Material Specifications (See Table C) Thermal Sensor:Beryllium Nickel -u. Strut and Lever.Stainless Steel Sensitivity . Roto-clip:Stainless Steel Quick-response i '° Sprinkler Frame:Brass Alloy Temperature Ratings Cap:Bronze Alloy 165°F(74°C) itt, Sealing Washer.Nickel with PTFE 212°F(100°C) Load Screw:Copper Alloy Recessed Escutcheons Deflector.Brass Alloy Model F1 escutcheon(cULus only) SprinklerModel F2 escutcheon Wrenches Model FP escutcheon(cULus only) Model W2(HSW) Model W1 (recessed) Guards Model J(with guard installed) F-7 Guard(cULus) F-4 Guard(FM) Model KFR56 HSW Sprinkler Components and Dimensions Figure 3 ismi } 0 1 I01] 11 1 1/4" DEFLECTOR I IINII� � (32 lmm) • I —COMPRESSION SCREW )I _! 1 FUSIBLE LINK --- 2 11/16" (68 mm) SEALING ASSEMBLYaiiis r-----= s= WRENCH FLATS FRAME 5/B (16 mm) • Bulletin 036 Reliable www Page 4 of 7 January 2020 .reliabiesprinkler.com Recessed Escutcheon and Conical Concealed Cover Plate Dimensions Table B Maximum Face of Minimum Face Maximum Minimum • Adjustment Fitting to of Fitting to Deflector Deflector Type Inch (mm) Ceiling* Ceiling' Distance Below Distance Below Inch(mm) Inch(mm) Ceiling Ceiling Inch(mm) Inch (mm) Fl 3/4 7/8 1/8 1-3/4 1 (19) (24) (3) (44) (25) F2 lb 5/8 1/8 1-3/4 1-1/4 (12) (16) (3) (44) (32) FP 1/2 1-1/2 1 1 1/2 (12) (38) (25) (25) (12) CCP 1/2 1-1/2 1 1 1/2 (12) (38) (25) (25) (12) *Note:Face of fitting to ceiling dimensions are based on nominal thread make up.Verify dimensions based on fitting and thread sealing method prior to installation. Recessed Escutcheon and Conical Concealed Cover Plate Diagrams Figure 4 --2 1/4'(57 mm)DIA.—, r2 1/4"(57 mm)DIA.— F1 RECESSED F2 RECESSED ESCUTCHEON 7/8"(24 mm) ESCUTCHEON J 5/8"(16) 3/4"(19 mm) MAX.FACE 1/2"(13 mm) 1 MAX.FACE ADJUSTMENT 1 15/16" OF FITTING ADJUSTMENT 1 1 15/16" L (49 mm)DIA.) T OF FITTING TO FACE (49 mm)DIA. i TO FACE OF CEILING I ' ` I ' OF CEILING I- , , 1 0 1 ,_0" Fr A ai 1 3/4" 1 3/4" (44 mm) 1" (44 mm) 1 1/4" (25 mm) (32 mm) MINIMUM I MAXIMUM MINIMUM MAXIMUM RECESS --- 2 7/8"(72 mm)DIA. RECESS RECESS —2 7/8"(72 mm)DIA. RECESS Fl RECESSED ESCUTCHEON INSTALLATION F2 RECESSED ESCUTCHEON INSTALLATION /: _ : : (67 mm)DIA. (67 mm)DIA. CCP C•`VER 1 1 • (32 mm) FP REC', ED PLATE J - 1/4"(6 mm) ESCUTCH o 1 "(A mm) 1/2"(13 mm) 2 5/16" MAX.FACE OF 1/2"(13 mm) 1 AX.FACE OF ADJUSTMENT 2 5/16" FITTING TO (59 mm)DIA. / FACE FO ADJUSTMENT +(59 mm)DIA. FACE OF 1 CEILING I CEILING ,7, ice ;ii,..-- , , , r/: v/, , • _ in ��� / 15/16" (25 mm) 112" 24mm A (13 mm) MINIMU REC-:S 3 3l16"(81 mm)DIA. MUM 3 5J16"(84 mm)DIA. RE• SS Bulletin 036 Page 5 of 7 January 2020 Reliable wwwreliablesprinkler.com Model KFR56 HSW Recessed Escutcheon Dia•rams Figure 5 1/2"(12 mm) +/- 3/8"(10 mm) __ — 1 3/8"(35 mm)MAXIMUM RECESS • FACE OF FITTING / TO FACE OF WALL 1 1 i-f -\r 4"-12"(102 mm-305 mm) 2 1/4" ( 15/16" TOP OF DEFLECTOR TO 2 7/8" 10EILING DISTANCE (57 mm) (49 mm) - -- -- - (73 mm) DIA. DIA. DIA. ESCUTCHEO j�✓ ESCUTCHEON /// 3/4'(19 mm)ADJ. �j 2 1/8"(54 mm)MINIMUM RECESS Fl RECESSED ESCUTCHEON INSTALLATION 3/8"(16 mm) +/- 1/4"(6 mm) .I —1 5/8"(42 mm)MAXIMUM RECESS FACE OF FITTING TO FACE OF WALL Al 1 i16 4"-12 (102mm-305mm) 2TOP OF DEFLECTOR TO 1/4" 1 " 2 7/8" CEILING DISTANCE (57 mm) (49 mm) - (73 mm) • DIA. DIA. % DIA. Air grel F2 OR FV RECESSED ESCUTCHEON 1/2"(13 mm)ADJ. 2 1/8"(54 mm)MINIMUM RECESS F2 RECESSED ESCUTCHEON INSTALLATION 1 1/4"(32 mm) +/- 1/4"(6 mm) Al 7/8"(22 mm)MAXIMUM • • SS •CE OF 0 A TO '� E OFF WALL L r 4"-12"(102 mm-305 mm) TOP OF DEFLECTOR TO 2 5/8" 2 5/16" I hp;.1 CEILING DISTANCE 3 1/4" (67 mm) (58 mm) i — (83 mm) DIA. DIA. It,•:--"' I DIA. 0111 L FP REC : ED ES • CHEON /2"(13 mm)ADJ. --- 1 3/8"(35 mm)MINIMUM RECES • Bulletin 036 www.reliablesprinkler.comPage 6 of 7 January 2020 Sprinkler, Escutcheon,and Cover Plate Finishestlf Standard Finishes Special Application Finishes • Sprinkler Fi, F2,and Feat Escutcheons CCP Cover Plate Sprinkler Fi,F2, and FP zt Escutcheons CCP Cover Plate Bronze Brass -- B.igIIto,as., DJyht0,a°. DIiyl,t El,a.s Chronic Plated Chromc Plated Chromc Plated Dull Chromc Dull Chromc Dull Chromc White Polyester White Polyester Whik Rd,,t Black Polyoctor� Black Polyosto, Black Paint Vusto,,I VUIUI � r Felyeste Custom Color Pant flAye°t.,I Notes: (1)Paint or any other coating applied over the factory finish will void all approvals and warranties. (2)The Model FP escutcheon assembly consists of an unfinished galvanized cup with a finished escutcheon ring. Wrench ..., 1116 i v ? ilk Model W2(upright, pendent,&HSW) Model W1 (recessed pendent& HSW, CCP) Model J (with guard installed) Maintenance Ordering Information Reliable Model KFR56 series sprinklers should be inspected and Specify the following when ordering. • the sprinkler system maintained in accordance with NFPA 25,as well as the requirements of any Authorities Having Jurisdiction. Sprinkler Prior to installation, sprinklers should remain in the original • Model (KFR56 Pendent, KFR56 Upright, KFR56 Upright Intermediate, or KFR56 HSW) cartons and packaging until used.This will minimize the potential • Temperature Rating[165°F(74°C)or 212°F(100°C)] for damage to sprinklers that could cause improper operation or • Threads(1/2" NPT or ISO 7-1 R3/4) non operation. • Finish (See Table C) Do not clean sprinklers with soap and water, ammonia liquid or Escutcheon or Coverplate any other cleaning fluids. Remove dust by gentle vacuuming without touching the sprinkler. • Type(None, F1, F2, FP,or CCP) • Finish (See Table C) Replace any sprinkler which has been painted(other than factory Guards/Water Shields applied). A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. • See sprinkler information pages in this bulletin Failure to properly maintain sprinklers may result in inadvertent Sprinkler Wrench operation or non-operation during a fire event. • W2(Pendent,Upright, &HSW) • W1 (Recessed Pendent&HSW, CCP) Guarantee • J (with guard installed) For the Reliable Automatic Sprinkler Co., Inc. guarantee,terms, and conditions,visit www.reliablesprinkler.com. v • V O A OD W Bulletin 036 Page 7 of 7 January 2020 Ref www.reliablesprinkler.com 31-1530 Terrace Glen: Public Spaces Bulletin 034 February 2021 ® Model G5 Series Sprinklers elia Fibid Standard Spray, Flat Concealed Pendent Available with Gasketed Cover Plate • Features • Standard Coverage,Concealed Pendent(K2.8,4.2,5.6,&8.0 [40,60,80,&115 metric]) • Flat concealed cover plate available in a variety of finishes. -C • Available with Stainless Steel Clad cover plate(see Table I). - • 3/4-inch(19 mm)cover plate adjustment. • Cover plate available with optional gasket. Model G5 Cover Plate Model G5 Cover Plate Product Description with QR Gasket Model G5 series sprinklers are standard coverage,flat plate concealed sprinklers designed for installation in accordance with NFPA 13 and FM Global Property Loss Prevention Data Sheets.All Model G5 series sprinklers use a fusible-link operating element. _;' The sprinklers are offered with a standard Model G5 cover plate, a Model G5 cover plate with a quick-response(OR)gasket,or a Model G5 cover plate with a standard-response(SR)gasket. Model G5 sprinklers with a gasketed cover plate are intended for use in Model G5 Cover Plate dust free environments such as clean rooms. with SR Gasket Model G5 sprinklers must only be used with the Model G5 cover Note:Gasket material is silicone rubber,available in white only. • plate listed or approved with the sprinkler.Table A provides a summary of available Model G5 series sprinklers,along with Listing and Approval information for each sprinkler and cover plate combination. Model G5 Series Sprinkler Summary Table A K-Factor Listings Max.Working Sprinkler Sprinkler gpmlpsi12 Cover Plate and Sensitivity Pressure Identification Model (Uminlbar1'2) Model Approvals psi(bar) Number(SIN) G5 cULus QR FM S G5-28 �40) G5 QR Gasket cULus e R 75(12) RA3411 G5 SR Gasket • s, FM SR G5-42 4.2 Cf QR Casket cULus QR 175(12) RA3413 G5 cULus QR 250(17) FM, LPCB,VdS,CE SR 175(12) G5-56 (80� Q LULus QR 250(17) RA3415 -c C. SR Casket ULuz CR 2G0(17) FM SR 176(12) G5-56 300 (80) G5 QR Gasket cULus QR 300(21) 4 G5 SR Gasket cULus SR • G5 G5-80 8.0 G5 QR Gasket cU QR 175(12) RA3412 (115) G5 S cULus SR G5-80F 8. G5 FM SR 175(12) RA3417 15) G5 SR Gasket www.reliablesprinkler.com igodel G5-28 Standard Coverage,Concealed Pendent Sprinkler SIN RA3411 Tech ' al Specifications Sprinkler Temperature Ratings Style: •t Concealed Pendent 165°F(74°C) ° • Threads. "NPT or ISO 7-1 R1/2 212°F(100°C) '{ Nominal K- ,ctor:2.8(40 metric) Sensitivity Max.Workin a ressure:175 psi(12 bar) (See Table B) * -4- • Material Specifica •ns Cover Plates t^ Fusible Link:Be Ili .� Nickel M ry Model G5 Sprinkler Body:Brass loy Model G5 QR Gasket(cULus only) Levers:Bronze Alloy Model G5 SR Gasket v Yoke:Brass Alloy Cover Plate Finishes Sealing washer:Nickel with P (See Table I) Load Screw:Bronze Alloy Sprinkler Wrench Towers:Copper Alloy Model Pins:Stainless Steel Deflector:Bronze Alloy Model FC N. ',. 2 Cup:Steel Listings and Approvals cULus Listed(Light Hazard only) FM Approved Model G5-28 Sprinkler Components and Dimensio . Figure 1 2-5/16" (58 mm) Dia. Threads —_ Body Cup '!1!1� �* 1 Ceiling Tower .► ate j N _LA Fusible Link 3/4"(19 mm)Max. �j 3/16"(5 mm) Ill Deflector(retracted) Cover Plate Adjustment Pin(extended)J j I \\.\\ Deflector(extended) _ /Model G4/G5 Cover Plate J 3-5ling Model G5-28 Sprinkler Sensitivity able B Listing or ApprCover Plate Model cULusG5 QR G5 OR Gasket QR -- G5 SR Gasket SR SR QR: Quick-response SR:Standard-response • Bulletin 034 Re�lablL Page 2 of 9 February 2021 www.reliablesprinkler.com h'odel G5-42 Standard Coverage,Concealed Pendent Sprinkler SIN RA3413 Tech al Specifications Sprinkler Temperature Ratings • Style: :t Concealed Pendent 165°F(74°C) Threads: •"NPT or ISO 7-1 RVz 212°F(100°C) 5 , . Nominal K-' or 4.2(60 metric) Sensitivity 7 Max.Working essure:175 psi(12 bar) (See Table C) Material Speclflcat s Cover Plates -y Fusible Link:Berylliu Nickel Model G5 ‘ill Sprinkler Body:Brass - ay Model G5 QR Gasket '�; Levers:Bronze Alloy Model G5 SR Gasket Yoke:Brass Alloy Cover Plate Finishes Sealing washer:Nickel with PT' (See Table I) Load Screw: Bronze Alloy Towers:Copper Alloy Sprinkler Wrench ` Pins:Stainless Steel Model W3 Deflector:Bronze Alloy Model FC411/Cup:Steel Listings and Approvals ;, cULus Listed(Light Hazard only) Model G5-42 Sprinkler Components and Dimensio Figure 2 2-5/16" (58 mm) Dia. Threads 1_ Body a}i= Ceiling 11101111 Tower -► 4. Wlli ,,j ` Fusible Link i 3/4"(19 mm)Max. - Deflector(retracted) f Cover Plate Adjustment ;;;;;;;;2; 3/16"(5 mm) • Pin(extended) / , I Deflector(extended) �^� I 'A 1 Model G4/G5 Cover Plate 3-5/16"(84 ' )Dia.-- Ceiling Model G5-42 Sensitivity Table C Listing or Approval Agency Cover Plate Model cULus G5 OR G5 QR Gasket OR G5 SR Gasket SR QR: Quick-response SR: Standard-response • Bulletin 034 Reliable Page 3 of 9 February 2021 www.reliablesprinkler.com Model G5-56 Standard Coverage,Concealed Pendent Sprinkler SIN RA3415 Technical Specifications Sprinkler Temperature Ratings Style: Flat Concealed Pendent 165°F(74°C) Threads:'/2"NPT or ISO 7-1 R1/2 212°F(100°C)(cULus,FM,LPCB,CE only) Nominal K-Factor:5.6(80 metric) Sensitivity **'�' Max.Working Pressure: (See Table D) 175 psi(12 bar) %4 • 250 psi(17 bar)(cULus only) Cover Plates tilik Model G5 "-° ,�` Material Specifications Model G5 QR Gasket(cULus only) i►' Fusible Link:Beryllium Nickel Model G5 SR Gasket(cULus and FM only) \..., Sprinkler Body:Brass Alloy M; - Levers: Bronze Alloy Cover Plate Finishes ,, Yoke:Brass Alloy (See Table I) Sealing washer:Nickel with PTFE Sprinkler Wrench Load Screw:Bronze Alloy Model W3 Towers:Copper Alloy Model FC - y„,� Pins:Stainless Steel Listings and Approvals .-"#. fa. `d, - Deflector Bronze Alloy cULus Listed(Light&Ordinary Hazard only) y .*4 Cup:Steel FM Approved LPCB Approved VdS Approved [165°F(74°C)only] ' --'.,„.' ; CE Listed(2831-CPR-S2062) Model G5-56 Sprinkler Components and Dimensions Figure 3 2-5/16" (58 mm) - Dia, Threads Body �i-� ■ � Cup ' i�' ��m1�_ � Ceiling 1 �'. Tower ci► i win ` 're1► al Fusible Link 3/4"(19 mm) Max. 3l16"(5 mm) Deflector(retracted) Cover Plate Adjustment Pin(extended) NI � Deflector(extended) Model G4/G5 Cover Plate 3-5/16"(84 mm) Die. Ceiling Model G5-56 Sensitivity Table D Listing or Approval Agency Cover Plate Model cULus FM LPCB,VdS,CE G5 OR SR SR , J UJ U 1!J U1 L4. L! 1Jr1 A L! \l1 ` W L' 1.A1 V- .k. 1-. GC QR Casket OR G5 CR Ga3kct CR CR QR: Quick-response SR: Standard-response • Bulletin 034 Reliable Page 4 of 9 February 2021 www.reliablesprinkler.com Model G5-56 300 Standard Coverage,Concealed Pendent Sprinkler SIN RA4014 Techn al Specifications Sprinkler Temperature Ratings • Style: ' -t Concealed Pendent 165°F(74°C) Threads: •"NPT or ISO 7-1 R/z 212°F(100°C) . Nominal K-• tor:5.6(80 metric) Sensitivity .. Max.Working ' essure:300 psi(21 bar) (See Table E) Z ' Material Specifica s Cover Plates Fusible Link:Berylliu • Nickel Model G5 °°� Sprinkler Body:Brass oy Model G5 QR Gasket - `-, Levers:Bronze Alloy �- '�-,a.. Model G5 SR Gasket ^� Yoke:Brass Alloy Sealing washer:Nickel with P Cover Plate Finishes Soev (See Table I) �• 9 Load Screw:Bronze Alloy # , , . Towers:Copper Alloy Sprinkler Wrench Pins:Stainless Steel Model W3 Deflector Bronze Alloy Model FC Cup:Steel Listings and Approvals cULus Listed(Light&Ordinary Hazard only) Model G5-56 300 Sprinkler Components and Dim- •sions Figure 4 2-5/16" (58 mm) Dia. Threads { Body I Cup R1�!1!�I_ Ceiling Tower .► ata �' S�'>t Fusible Link 3/4"(19 mm)Max. 11 • Deflector(retracted) I Cover Plate Adjustment ,,,,,,,, r 3/16"(5 mm) 1 Pin(extended) I 1 ,� Deflector(extended) :,y i. Model G4/G5 Cover Plate 3-5/16" mm)Dia. Ceiling Model G5-56 300 Sensitivity Table E Listing or Approval Agency Cover Plate Model cULus G5 QR G5 QR Gasket QR G5 SR Gasket SR QR: Quick-response SR:Standard-response • Bulletin 034 Page 5 of 9 February 2021 e1 www.reliablesprinkler.com `1odel G5-80 Standard Coverage,Concealed Pendent Sprinkler SIN RA3412 Tech cal Specifications Sprinkler Temperature Ratings Style. at Concealed Pendent 165°F(74°C) • Thread 4"NPT or ISO 7-1 R3/4 212°F(100°C) �►<,} Nominal actor:8.0(115 metric) Sensitivity ; Max.Workin• •ressure:175 psi(12 bar) (See Table F) 4 t Material Speciflca, •ns Cover Plates • k,1 Fusible Link:Berylli6• Nickel Model G5 c? r- Sprinkler Body:Brass ' loy Model G5 QR Gasket '' µ Levers:Bronze Alloy Model G5 SR Gasket w Yoke:Brass Alloy Cover Plate Finishes Sealing washer:Nickel with P (See Table I) ' Load Screw:Bronze Alloy [sW : Towers:Copper Alloy Sprinkler Wrench V I° mil , Pins:Stainless Steel Model W3 Deflector:Bronze Alloy Model FC `- Cup:Steel Listings and Approvals cULus Listed(Light&Ordinary Hazard only) Model G5-80 Sprinkler Components and Dimensio Figure 5 2-5/16" (58 mm) - Dia. Threads Body GUp IT. 1�M Ceiling - S — Tower "11_►" �_ w s::"\ F. .•. by Fusible Link 3/4"(19 mm)Max. ` . Deflector(retracted) Cover Plate Adjustment f + Pin(extended) I Deflector(extended)---t_ _ } Model G4/G5 Cover Plate 3-5/16"(84 • )Dia.— Ceiling Model G5-80 Sensitivity Table F Listing or Approval Agency Cover Plate Model cULus G5 QR G5 QR Gasket OR G5 SR Gasket SR QR:Quick-response SR:Standard-response • Bulletin 034 �ieliabl"t Page 6 of 9 February 2021 www.reliablesprinkler.com Mt.lel G5-80F Standard Coverage,Concealed Pendent Sprinkler SIN RA3417 Technl Specifications Sprinkler Temperature Ratings • Style:FI. oncealed Pendent 165°F(74°C) Threads:3, PT or ISO 7-1 R3/4 212°F(100°C) #' Nominal K-Fa• •r:8.0(115 metric) Sensitivity Max.Working P --ure: 175 psi(12 bar) Standard Response " v ., - :7 b 3 r;, Material Specificatio Cover Plates +` $ ' - Fusible Link:Beryllium kel Model G5 + },r Sprinkler Body:Brass All. Model G5 SR Gasket - Levers:Bronze Alloy Cover Plate Finishes Yoke:Brass Alloy (See Table I) Sealing washer:Nickel with PTFE Load Screw:Bronze Alloy Sprinkler Wrench Towers:Copper Alloy Model W3 •� • Pins:Stainless Steel Model FC Deflector:Stainless Steel Listings and Approvals Cup:Steel FM Approved Model G5-80F Sprinkler Components and Dimension Figure 6 2-5/16" (58 mm) Dia. Threads Body } F Cup ij Ceiling Toer i " Fusible Link 3/4"(19 mm)Max. Deflector(retracted) Cover Plate Adjustment "... Pin(extended) f 4 � Deflector(extended) — _,x, ' ' Model G4/G5 Cover Plate 3-5/16"(84 mm •ia.— Ceiling Model G5-80F Sensitivity Table G Listing or Approval Agency Cover Plate Model FM G5 SR G5SR Gasket SR SR:Standard-response • Bulletin 034 Page 7 of 9 February 2021 Reliable www.reliablesprinkler.com Installation Dimensions and Cover Plate Information Table H Min.to Max. Min.to Max. Recommended Dropped Cover Plate • Cover Plate Cover Plate Face of Fitting Hole Diameter in Deflector Temperature Cover Plate Diameter Adjustment to Ceiling Distance Rating Model Inch Inch Inch Ceilings' below Ceiling °F (mm) (mm) (mm) Inch Inch (°C) (mm) (mm) G5 3-5/'s(84) 135°Foi 3-11/16 (57°C) G5 QR Gas 2-5/8 3/4 1-1/2 t0 2-1/4 I/4 t0 1 (67) (19) (38 to 57) (6 to 25) or 165°F > G5 SR Gaskets 4mm) (74°C) Notes: 1. Face of fitting to ceiling dimensions are based on nominal thread make up. Verify dimensions based on fitting and thread sealing method prior to installation.A'/2"x'/2"brass nipple extension(Reliable P/N 6999991900)is available to assist with replacement of Reliable Model G4A sprinklers. 2. Model G5 QR Gasket and Model G5 SR Gasket cover plates are sold as assembled units including both the cover plate and gasket.WIodeJ G5 QR Gasket and Model G5 SR Gasket cover plates and gaskets are not interchangeable. 3. For use with 165°F(74°C)temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100°F(38°C). 4. For use with 212°F(100°C)temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 150°F(66°C). Cover Plate Finishest'tnt Table I st•,__. 'es Special Application Finishes �, f111�1, �;�, Listing Approval Agencies lit Off-White Paint Individual Model G5 series sprinkler may be listed or approved by Black Writ the following agencies: Custom Color It t(Specifyri • Underwriters Laboratories, Inc.and UL Canada(cULus) Raw Bras(( erect) Listing Category:Sprinklers,Automatic and Open • £t b Guide Number:VNIV ronze(4 • FM Approvals(FM) 4 Plated • Loss Prevention Certification Board(LPCB) ril'in Chrome la Stainless Steel Clads) VdS SchadenverhOtung GmbH(VdS) • EC-Certificate of Conformity 0832-CPD-2062 (CE) Notes: See Table A and the individual sprinkler data sheets in this Bulletin 1. Paint or any other coating applied over the factory finish will void all for listings and approvals applicable to each sprinkler. approvals and warranties. 2. Cover plates do not carry corrosion resistant listings or approvals. 3. Custom color paint is semi-gloss unless specified otherwise. 4. Not listed for use with QR sealing gasket. Installation 5. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Alloy on the back side. Model G5 series sprinklers are intended to be installed in accordance with NFPA 13, FM Global Property Loss Prevention Data Sheets, and the requirements of applicable authorities Application having jurisdiction. Model G5 series sprinklers must not be Model G5 series sprinklers are standard coverage,flat plate installed in ceilings with positive pressure in the space above. concealed pendent sprinklers.The sprinklers are intended for Ensure that the 4 slots in the cup are open and unobstructed use in accordance with NFPA 13 and FM Global Property Loss following installation. Prevention Data Sheets,as well as the requirements of the Model G5 series sprinklers are shipped with a wrench-able applicable approval agencies. protective cap that should remain on the sprinkler until the sprinkler system is placed in service following construction. Model G5 series sprinklers are available as either Quick-response Model G5 series sprinklersjan be installed without removing (OR) or Standard-response(SR)depending on the approval the wrench-able protective cap using the Model W3 wrench. agency and cover plate selected. Alternatively, Model G5 series sprinklers can be installed using the Model FC wrench by temporarily removing the protective cap Model G5 series sprinklers use Model G5 flat cover plates. Model during installation of the sprinkler.The use of any other wrench G5 QR Gasket and G5 SR Gasket cover plates are available to to installed Model G5 series sprinklers is not permitted and may • limit air and dust movement through the ceiling. damage the sprinkler. Bulletin 034 Reliably Page 8 of 9 February 2021 www.reliablesprinkler.com Wrench ... , ,.....—.: Lo.../Mk Aft Model FC Model W3 k> .. For use with Model G5 Series sprinklers For use with Model G5 Series sprinklers with without wrench-able cap installed wrench-able cap installed I Fully insert the Model W3 wrench over the cap until it reaches Replace any sprinkler or cover plate which has been painted(other the bottom of the cup, or the Model FC wrench over the sprinkler than factory applied). Properly installed Model G5 cover plates will until the wrench engages the body. Do not wrench any other have an air gap that is required for proper operation, do not seal part of the sprinkler/cup assembly.The Model W3 and FC the gap or paint the cover plates. Model G5 series sprinklers have wrenches are designed to be turned with a standard 1/2"square holes in the cup that must remain unobstructed. drive.Tighten the sprinkler into the fitting after applying a PTFE Replace any sprinkler which has been damaged.A stock of spare based thread sealant to the sprinkler's threads. Recommended sprinklers should be maintained to allow quick re-placement installation torque is specified in Table J. of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadvertent operation or non-operation during a fire event. Installation Torque Table J Recommended Installation Guarantee • Sprinkler Threads Torque (min.—max.) For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, ft.lb N.m and conditions,visit www.reliablesprinkler.com. /z" NPT or IS07-1 Rt/2 8-18 11-24 ' " NPT or ISO7-1 R3/4 14-20 19-27 Patents Do not exceed the maximum recommended torque.Exceeding the Model G5 series sprinklers may be covered by one or more of the maximum recommended torque may cause leakage or impairment following patents: of the sprinkler. Use care when inserting or removing the wrench U.S. Patent 6,554,077, U.S. Patent 7,275,603, U.S. Patent from the sprinkler to avoid damage to the sprinkler. 8,776,903, U.S. Patent 9,248,327 Install the cover plate by hand, pushing and then turning the cover Ordering Information in the clockwise direction until it is tight against the ceiling. For Specify the following when ordering. Model G5 QR Gasket and Model G5 SR Gasket cover plates, the gasket should be attached to the flange of the cover plate skirt Sprinkler only. Do not glue the gasket in place or allow the gasket to overlap • Model[G5-28][G5-42] [G5-56][G5-56 300] both the cover plate and the flange of the skirt. [G5-80][G5-80F] • Temperature Rating [165°F(74°C)] [212°F(100°C)] Maintenance • Threads[NPT or ISO 7-1] Reliable Model G5 series sprinkler should be inspected and the Cover Plate sprinkler system maintained in accordance with NFPA 25, as well • Model[G5, G5 QR Gasket,G5 SR Gasket] as the requirements of any Authorities Having Jurisdiction. • Finish(See Table I) Prior to installation,sprinklers should remain in the original cartons Sprinkler Wrench and packaging until used. This will minimize the potential for • Model W3 damage to sprinklers that could cause improper operation or non- • Model FC operation. Do not clean sprinklers with soap and water,ammonia liquid or any v • other cleaning fluids. Remove dust by gentle vacuuming without ti touching the sprinkler. rn CD rn rn a) z Bulletin 034 Page 9 of 9 February 2021 Wrifila www.reliablesprinkler.com 31-1530 Terrace Glen: Attic Space Bulletin 056 March 2021 ® Models DD56-6, DD56-27, DD80-6, DD80-27, • ' DS56, GP56, AH42, &AH56 Sprinklers Specific Application Sprinklers for Attic Spaces cULus Listed Features • Coverage for DD80 spans up to 70 ft(21 m)with one row of sprinklers x a I. • Coverage for DD80 spans up to 100 ft(30.5 m)with three {,, rows of sprinklers • All models use a 212°F(100°C)temperature rated fusible- 1 - link operating element r',; ," • 150 square foot per sprinkler protection using GP56 and AH Series sprinklers Model DD56 (Model DD80 similar)) Model DS56 Product Description Reliable Attic Sprinklers are cULus Listed Specific Application sprinklers.The sprinklers are available for protection of combustible and non-combustible light hazard concealed ..,..' . spaces with roof/ceiling slopes of 4:12 to 8:12. Reliable 401 id Attic Sprinklers are upright sprinklers listed for use on t.,: •wet-pipe or dry-pipe sprinkler systems.All Reliable Attic 3 sprinklers use a 212°F(100°C)temperature rated fusible- link operating element that is Listed for installation where the 1 Model AH56 maximum ceiling temperature is up to 150°F(66°C). Table A Model GP56 provides a summary of available Reliable Attic sprinklers. (Model AH42 similar) • Application reflect all possible construction methods. In some cases, a combination of layouts may be required. The Authority Reliable Attic Sprinklers are listed for installation in Having Jurisdiction should be consulted for situations accordance with this bulletin and NFPA 13, "Standard for the that are not specifically addressed within this bulletin. Installation of Fire Sprinklers." The sprinklers are classified as Special Sprinklers by NFPA 13, and are intended for Special Note Regarding Insulation installation within combustible or noncombustible roof structures, including those with wooden trusses. Coverage Noncombustible insulation, properly secured with wire area,spacing requirements, and design flow and pressure netting to prevent sagging onto sprinklers may be used for each sprinkler are provided in tables B-I on the individual at the roof deck. Spray foam has not been evaluated for sprinkler data sheets in this bulletin. Example sprinkler use with attic sprinklers. Use of spray foam insulation layouts and hydraulic design criteria are provided in Figures with attic sprinklers should be evaluated on a case by 9 through 25. Please note that the example sprinkler layouts case basis with the Authority Having Jurisdiction. are intended as design aids only, and do not necessarily Attic Sprinkler Summary Table A Sprinkler K-Factor Thread Size Max.Coverage Area Sprinkler Model gpm/psi'"2 NPT or (Measured on Floor) Roof Slope Design Criteria Identification (Umin/bar") IS07-1 ft x ft(m x m) Number(SIN) DD56-6 5.6(80) Y2 6 x 40(1.8 x 12) 4:12 to <6:12 Table B RA5624 DD56-27 5.6(80) 1/2 6 x 40(1.8 x 12) 6:12 to 8:12 Table C RA5694 DD80-6 8.0(115) 3/4 6x66or5x70 4:12 to <6:12 Table D RA5622 (1.8 x 20 or 1.5 x 21) DD80-27 8.0(115) 34 6x66or5x70 6:12to8:12 TableE RA5692 (1,8x200r1.5x21)• DS56 5.6(80) 1/2 6 x 40(1.8 x 12) 4:12 to 8:12 Table F RA5625 GP56 5.6(80) Y2 10 x 15(3.0 x 4.6) 4:12 to 8:12 Table G RA5695 AH42 4.2(60) Y2 10 x 15(3.0 x 4.6) 4:12 to 8:12 Table H RA5623 AH56 5.6(80) 1 10 x 15(3.0 x 4.6) 4:12 to 8:12 Table I RA5626 www.reliablespri nkler.com Model DD56-6 Specific Application Sprinkler SIN RA5624 Technical Specifications Installation Criteria Style:Upright Sprinkler Spacing • Orientation:Deflector horizontal Minimum 4 ft(1.2 m),maximum 6 ft(1.8m) `"^- ' -w • ' Threads:1/2"NPT or ISO 7-1R1/2 between sprinklers along ridge Nominal K-Factor:5.6(80 metric) Minimum 26 ft(7.9 m)down the roof slope ` Max.Working Pressure:175 psi(12 bar) toward eave to nearest sprinkler, r Sprinkler Temperature Rating:212°F(100°C) measured parallel to the roof deck Sensitivity:Quick-response ! Horizontal Distance from Face of Truss 1,.,.; Hydraulic Design Criteria Min:6 inches(150 mm) (See Table B and Figures 9-29) Vertical Distance of Deflector Above Scissor 1 Finish Truss Brass Min: 18 inches(450 mm) Sprinkler Wrench Horizontal Distance from Center-line of Ridge Model W2 Max:6 inches(150 mm) Material Specifications Listings and Approvals Vertical Distance of Top of Deflector Below Thermal Sensor.Nickel Alloy Solder Link cULus Listed Peak,Ridge,or Deck Levers:Stainless Steel Min: 17 inches(430 mm) Sprinkler Frame:Brass Alloy Hazard Classification Max:21 inches(530 mm) Button:Copper Alloy Light Hazard Button Clip:Stainless Steel Sealing Assembly:Nickel Alloy with PTFE System Types Wet-pipe with steel or Listed CPVC pipe Load Screw Bronze Alloy Dry-pipe with steel pipe Deflector:Bronze Alloy Model DD56-6 Sprinkler Components and Dimensions Figure 1 1-3/32" 2-5/16" 1 (2 mm) r".-- (59 mm) 1 !Win ■i . Deflector I I laà ' I Dose - • ■ Fusible Link ieli ®, YEAR 2-1/2" inilli .„.11 Wrench Flat :!■+ .�� ��� 6 ��1(64 mm) �hASCO 212 F/q o c OFA@Threads ' v Model DD56-6 Minimum Required Flow and Residual Pressure Table B Ceiling Slope Max.Coverage Area Flow Pressure ft x ft(m x m) gpm(I/min) psi(bar) 4:12 to less than 6:12 6 x 40*(1.8 x 12) 25 (95) 19.9(1.37) Long dimension of coverage area to be along the roof slope parallel to trusses. Length of coverage area is split equally to each side of the sprinkler at the ridge. Coverage area is measured parallel to the floor. • Bulletin 056 Reliable Page 2 of 27 March 2021 www.reliablesprinkler.com Model DD56-27 Specific Application Sprinkler SIN RA5694 Technical Specifications Installation Criteria Style:Upright Sprinkler Spacingr Orientation:Deflector horizontal Minimum 4 ft(1.2 m),maximum 6 ft(1.8m) Threads:1/2"NPT or ISO 7-1R1/2 between sprinklers along ridge Nominal K-Factor:5.6(80 metric) Minimum 26 ft(7.9 m)down the roof slope Max.Working Pressure:175 psi(12 bar) toward eave to nearest sprinkler, 00 ' g Sprinkler Temp erature perature Rating:212°F(100°C) measured parallel to the roof deck Sensitivity:Quick-response Horizontal Distance from Face of Truss Hydraulic Design Criteria Min:6 inches(150 mm) r ys° (See Table C and Figures 9-29) Vertical Distance of Deflector Above Scissor Finish Truss Brass Min: 18 inches(450 mm) T Sprinkler Wrench Horizontal Distance from Center-line of Ridge Model W2 Max:6 inches(150 mm) s and ApprovalsMaterial Specifications Listing s Vertical Distance of Top of Deflector Below Thermal Sensor:Nickel Alloy Solder Link cULus Listed Peak,Ridge,or Deck Levers:Stainless Steel Min: 17 inches(430 mm) Sprinkler Frame:Brass Alloy Hazard Classification Max: 21 inches(530 mm) Button:Copper Alloy Light HazardpP y Button Clip:Stainless Steel System Types Sealing Assembly:Nickel Alloy with PTFE Wet-pipe with steel or Listed CPVC pipe Load Screw:Bronze Alloy Dry-pipe with steel pipe Deflector.Bronze Alloy Model DD56-27 Sprinkler Components and Dimensions Figure 2 1-3/32" 2-9/32" (28 mm) 1-....— (58 mm) ._. • Deflector I I ipi I I ( noo66 OR Fusible Link �' " c YEAR �_ 21r2" Wrench Flat III_ (64 mm) t.-I 11 �� 6 ASC® FIASCO • ` 212'F/100'C Threads - RA6894 �� 27' Model DD56-27 Minimum Required Flow and Residual Pressure Table C Ceiling Slope Max.Coverage Area Flow Pressure ft x ft(m x m) gpm(I/min) psi(bar) 6:12 to 8:12m 6x40*(1.8x12) 25(95) 19.9(1.37) * Long dimension of coverage area to be along the roof slope parallel to trusses. Length of coverage area is split equally to each side of the sprinkler at the ridge. Coverage area is measured parallel to the floor. • Bulletin 056 Reliable Page 3 of 27 March 2021 www.reliablesprinkler.com Model DD80-6 Specific Application Sprinkler SIN RA5622 Technical Specifications Installation Criteria Style:Upright Sprinkler Spacing .1 . Orientation:Deflector horizontal Minimum 4 ft(1.2 m),maximum 6 ft(1.8m) `"`-.. Threads:3/4"NPT or ISO 7-1 R3/4 between sprinklers along ridge �` _ , .„ Nominal K-Factor.8.0(115 metric) Minimum 26 ft(7.9 m)down the roof slope r Max.Working Pressure:175 psi(12 bar) toward eave to nearest sprinkler, r, Sprinkler Temperature Rating:212°F(100°C) measured parallel to the roof deck I Sensitivity:Quick-response ,- Horizontal Distance from Face of Truss Hydraulic Design Criteria Min:6 inches(150 mm) (See Table D and Figures 9-29) - ' ` Vertical Distance of Deflector Above Scissor _ "" Finish Truss Brass Min: 18 inches(450 mm) Sprinkler Wrench Horizontal Distance from Center-line of Ridge Model W2 Max:6 inches(150 mm) Material Specifications Listings and Approvals Vertical Distance of Top of Deflector Below Thermal Sensor:Nickel Alloy Solder Link cULus Listed Peak,Ridge,or Deck Levers:Stainless Steel Hazard Classification Min: 17 inches(430 mm) Sprinkler Frame:Brass Alloy azh Hazard Max: 21 inches(530 mm) Button:Copper Alloy LigButton Clip:Stainless Steel System Types Sealing Assembly:Nickel Alloy with PTFE Wet-pipe with steel or Listed CPVC pipe Load Screw:Bronze Alloy Dry-pipe with steel pipe Deflector:Bronze Alloy Model DD80-6 Sprinkler Components and Dimensions Figure 3 1-3/32" 2-5/16" 1 (28 mm) r (59 mm) - ■m■ ■�■ IIM Deflector ilrlill Iwà • l I Qom OR Fusible Linkiri iLL ©w YEAR 2 7!8" O Wrench Flat IM• (73 mm) 1-1 -ASCO RASCO � 212'F/ioa'c �� o Threads . � v Model DD80-6 Minimum Required Flow and Residual Pressure Table D Ceiling Slope Max.Coverage Area Flow Pressure ft x ft(m x m) gpm(I/min) psi(bar) 6 x 40*(1.8 x 12) 25 (95) 9.8(0.68) 6 x 63*(1.8 x 19) 38(144) 22.6(1.56) 4:12 to less than 6:12 6x66*(1.8x20) 40(151) 25(1.72) 5x70*(1.5x21) 38(144) 22.6(1.56) ` Long dimension of coverage area to be along the roof slope parallel to trusses. Length of coverage area is split equally to each side of the sprinkler at the ridge. Coverage area is measured parallel to the floor. • Bulletin 056 fellable www Page 4 of 27 March 2021 .reliablesprinkler.com Model DD80-27 Specific Application Sprinkler SIN RA5692 Technical Specifications Installation Criteria . Style:Upright Sprinkler Spacing Orientation:Deflector horizontal Minimum 4 ft(1.2 m),maximum 6 ft(1.8m) Threads:3/4"NPT or ISO 7-1R3/4 between sprinklers along ridge !: $a Nominal K-Factor.8.0(115 metric) Minimum 26 ft(7.9 m)down the roof slope =ate a i., , Max.Working Pressure:175 psi(12 bar) toward eave to nearest sprinkler, a° Sprinkler Temperature Rating:212°F(100°C) measured parallel to the roof deck Sensitivity:Quick-response Horizontal Distance from Face of Truss Hydraulic Design Criteria Min:6 inches(150 mm) • "'. t (See Table E and Figures 9-29) Vertical Distance of Deflector Above Scissor ' '" Finish Truss Brass Min: 18 inches(450 mm) F Sprinkler Wrench Horizontal Distance from Center-line of Ridge Model W2 Max:6 inches(150 mm) Material Specifications Listings and Approvals Vertical Distance of Top of Deflector Below Thermal Sensor.Nickel Alloy Solder Link cULus Listed Peak,Ridge,or Deck Levers:Stainless Steel Min: 17 inches(430 mm) Sprinkler Frame:Brass Alloy Hazard Classification Max:21 inches(530 mm) Button:Copper Alloy Light Hazard Button Clip:Stainless Steel System Types Sealing Assembly:Nickel Alloy with PTFE Wet-pipe with steel or Listed CPVC pipe Load Screw:Bronze Alloy Dry-pipe with steel pipe Deflector:Bronze Alloy Model DD80-27 Sprinkler Components and Dimensions Figure 4 1-3/32" 2-9/32" 1 (28 mm) r (58 mm) ■!■ ■T■ . • 1q1 1,a IDeflector ,I I I Q , OR Fusible Link — = `' .' �©g YEAR iiii 2-7/8" , Wrench Flat I$I!1 (73 mm) � ` �' �� E 0 3 fAC® f�A 212'Pf 100'C -1111111, O Threads Z, Model DD80-27 Minimum Required Flow and Residual Pressure Table E Ceiling Slope Max. Coverage Area Flow Pressure ft x ft(m x m) gpm(I/min) psi (bar) 6 x 40*(1.8 x 12) 28(106) 12.3(0.85) 6 x 63*(1.8 x 19) 38(144) 22.6(1.56) 6:12 to 8:12 6 x 66*(1.8 x 20) 40(151) 25(1.72) 5 x 70*(1.5 x 21) 38(144) 22.6(1.56) *Long dimension of coverage area to be along the roof slope parallel to trusses. Length of coverage area is split equally to each side of the sprinkler at the ridge. Coverage area is measured parallel to the floor. • Bulletin 056 Rel Page 5 of 27 March 2021 www.reliablesprinkler.com Model DS56 Specific Application Sprinkler SIN RA5625 Technical Specifications Installation Criteria Style:Upright Sprinkler Spacing , ''". IIIOrientation:Frame arms Minimum 4 ft(1.2 m),maximum 6 ft(1.8m) " " ` * perpendicular to roof deck between sprinklers along ridge ,a` Threads:1/2"NPT or ISO 7-1 R1/2 Minimum 26 ft(7.9 m)down the roof slope Nominal K-Factor.5.6(80 metric) toward eave to nearest sprinkler, ) Max.Working Pressure:175 psi(12 bar) measured parallel to the roof deck Sprinkler Temperature Rating:212°F(100°C) Sensitivity:Quick-response Horizontal Distance from Face of Truss Min:6 inches(150 mm) x • Y Design draulic Desi n Criteria v (See Table F and Figures 9-29) Horizontal Distance from Draft Curtain or Wall ' k } Min:30 inches(762 mm) Finish Max:42 inches(1067 mm) Brass Sprinkler Wrench Vertical Distance of Top of Deflector Above ?' Model DS56 Bottom of Draft Curtain Min:8 inches(200 mm) Material Specifications Listin s and Approvals 9 PP cULus Listed Thermal Sensor.Nickel Alloy Solder Vertical Distance of Deflector Above Scissor Link Hazard Classification Truss Levers:Brass Alloy Light Hazard Min: 18 inches(450 mm) Frame Body:Brass Alloy System Types Distance from Top of Deflector to Roof Deck Frame Arms:Brass Alloy Wet-pipe with steel or Listed CPVC pipe (measured perpendicular to roof deck) Yoke:Copper Alloy Dry-pipe with steel pipe Min:9 inches(230 mm) Sealing Assembly:Nickel Alloy with Max: 13 inches(330 mm) PTFE Load Screw:Bronze Alloy Deflector:Bronze Alloy (1)Model DS56 sprinklers may be installed back-to-back on opposite sides of a ridge where a draft curtain is installed to separate the back-to-back rows of sprinklers. Model DS56 Sprinkler Components and Dimensions Figure 5 1-9/16" _ 1-11/16" • (40 mm) (43 mm) Deflector i,E' k /, ;t ��� RASCO j AiiiiM �h (� i/= Fusible Link II 11.0. rI 2-13/16" w—"7 I °Sinc Nit Wrench Flat (71 mm) aco =I �1 _El ...,:..„ Threads �` 1 �— Model DS56 Minimum Required Flow and Residual Pressure Table F Ceiling Slope Max.Coverage Area Flow Pressure ft x ft(m x m) gpm(I/min) psi(bar) 6x30*(1.8x9.1) 23(87) 16.9(1.17) 4:12 to 8:12 6 x 40*(1.8 x 12) 35(132) 39.1 (2.70) *Long dimension of coverage area to be along the roof slope parallel to trusses. Length of coverage area is from the draft curtain or wall behind the sprinkler toward the eave. Coverage area is measured parallel to the floor. • Bulletin 056 WM Page 6 of 27 March 2021 www.reliablesprinkler.com Model GP56 Specific Application Sprinkler SIN RA5695 Technical Specifications Installation Criteria 4 f • Style:Upright Sprinkler Spacing 1i I : _ Orientation:Top of deflector parallel to roof deck Minimum 6 ft(1.8 m),maximum 10 ft(3.0 m) Threads:1/2"NPT or ISO 7-1R1/2 between sprinklers across roof slope. Nominal K-Factor 5.6(80 metric) Minimum 6 ft(1.8 m)up roof slope to -, Max.Working Pressure:175 psi(12 bar) nearest sprinkler,minimum 10 ft(3.0 ' ' ,,,. Sprinkler Temperature Rating:212°F(100°C) m)down slope to nearest sprinkler, Sensitivity:Quick-response measured parallel to roof deck. I Hydraulic Design Criteria Distance from Top of Deflector to Roof Deck l See Table G and Figure 9-29) (measured perpendicular to roof deck) Min:9 inches(230 mm) ' Finishs Max: 13 inches(330 mm) + Sprinkler Wrench Model W2 ListingsMaterial Specifications and Approvals cULus Listed Thermal Sensor:Nickel Alloy Solder Link Levers:Stainless Steel Hazard Classification Sprinkler Frame:Brass Alloy Light Hazard Button:Copper Alloy Button Clip:Stainless Steel System Types Sealing Assembly:Nickel Alloy with PTFE Wet-pipe with steel or Listed CPVC pipe Load Screw:Bronze Alloy Dry-pipe with steel pipe Deflector.Bronze Alloy Model GP56 Sprinkler Components and Dimensions Figure 6 1-7/8" 1-1/4" i (48 mm) (32 mm) Deflector 1-�N N 11 • .w► .-. ,\ un .` -� iiFusible Link = =(64mm) II Threads Model GP56 Minimum Required Flow and Residual Pressure Table G Max.Coverage Area Flow Pressure Ceiling Slope ft x ft gpm psi (m x m) (I/min) (bar) 4:12to8:12 10x15* 17 9.2 (3.0 x 4.6) (64) (0.63) *Long dimension of coverage area to be along the roof slope parallel to trusses. Coverage is 3 ft. (0.9m)toward the peak and 12 ft. (3.7m)toward the eave from the sprinkler. Coverage area to be measured parallel to the floor. • Bulletin 056 Relia6l Page 7 of 27 March 2021 www.reliablesprinkler.com Model AH42 Specific Application Sprinkler SIN RA5623 Technical Specifications Installation Criteria Style:Upright Sprinkler Spacing + • Orientation:Top of deflector parallel to roof deck Minimum 5 ft(1.5 m), maximum 10 ft(3.0 m) ! , .`• — Threads:1/2"NPT or ISO 7-1R1/2 between sprinklers across roof slope. Nominal K-Factor.4.2(60 metric) Minimum 12 ft(3.7 m)down slope to nearest ' Max.Working Pressure:175 psi(12 bar) sprinkler,measured parallel to roof deck. Sprinkler Temperature Rating:212°F(100°C) Note:A minimum 2 ft(0.61 m)lateral offset ' Sensitivity:Quick-response is required between AH sprinklers when viewed looking up the roof slope. Hydraulic Design Criteria (See Table H) Finish Distance from Top of Deflector to Brass Bottom of Truss Top Chord(measured Sprinkler Wrench perpendicular to roof deck) "_� p Min: 1 inches(25 mm) Model W2 Max:3 Inches(76 mm) Material Specifications Thermal Sensor.Nickel Alloy Solder Link Listings and Approvals Levers:Stainless Steel cULus Listed') Frame Arm Orientation Sprinkler Frame:Brass Alloy Hazard Classification Frame arms are to be oriented Button:Copper Alloy Light Hazard parallel to the eave at the bottom Button Clip:Stainless Steel of the protected space. Sealing Assembly:Nickel Alloy with PTFE System Types Load Screw:Bronze Alloy Wet-pipe with steel or Listed CPVC pipe Deflector.CHROME PLATED Bronze Alloy Dry-pipe with steel pipee2) Note: (')Listed for the protection of sloped combustible and noncombustible concealed spaces, including hip roofs with traditionally framed or step down truss construction. (2)NFPA13 requires the use of corrosion resistant or internally galvanized steel piping when using sprinklers with a K-Factor of 4.2. Model AH42 Sprinkler Components and Dimensions Figure 7 1-5/8" • (41 mm) Deflector Fusible Link I L 2-5/16" h U ' Wrench Flat * 2OA. (59 mm) ' / Threads — AH42 DEFLECTOR IS CHROME PLATED Model AH42 Minimum Required Flow and Residual Pressure Table H Ceiling Slope Max.Coverage Area Flow Pressure ft x ft(m x m) gpm (I/min) psi (bar) 4:12 to 8:12 10 x 15*(3.0 x 4.6) 15(57) 12.8(0.88) *Long dimension of coverage area to be along the roof slope. Coverage is 6'-0"(1.8m)toward the peak and 9'-0"(2.7m)toward the eave from the sprinkler. Coverage area to be measured parallel to the floor. Note:The first row of AH sprinklers may be a maximum of 9'-0"from the eave; however,the first row must always be on the eave side IIIof the girder truss(see Figures 24 and 25). Bulletin 056 Re �a �� Page 8 of 27 March 2021 www.reliablesprinkler.com Model AH56 Specific Application Sprinkler SIN RA5626 Technical Specifications Installation Criteria • Style:Upright Sprinkler Spacing _ -., Orientation:Top of deflector parallel to roof deck Minimum 6 ft(1.8 m), maximum 10 ft(3.0 m) + * Threads:1/2"NPT or ISO 7-1R1/2 between sprinklers across roof slope. Nominal K-Factor.5.6(80 metric) Minimum 12 ft(3.7 m)down slope to nearest Max.Working Pressure:175 psi(12 bar) sprinkler,measured parallel to roof deck. Sprinkler Temperature Rating:212°F(100°C) Note:A minimum 2 ft(0.61 m)lateral offset Sensitivity:Quick-response is required between AH sprinklers when viewed looking up the roof slope. Hydraulic Design Criteria r , f c;fCe (See Table I) a a I Finish Distance from Top of Deflector to Brass Bottom of Truss Top Chord(measured Sprinkler Wrench perpendicular to roof deck) Model W2 Min: 1 inches(25 mm) Max:3 inches(76 mm) Material Specifications Listings and Approvals Thermal Sensor:Nickel Alloy Solder Link cULus Listed" Frame Arm Orientation Levers:Stainless Steel Hazard Classification Frame arms are to be oriented Sprinkler Frame:Brass Alloy Light Hazard parallel to the eave at the bottom Button:Copper Alloy of the protected space. Button Clip:Stainless Steel System Types Sealing Assembly:Nickel Alloy with PTFE Wet-pipe with steel or Listed CPVC pipe Load Screw:Bronze Alloy Dry-pipe with steel pipe Deflector:Bronze Alloy *Note:Listed for the protection of sloped combustible and noncombustible concealed spaces,including hip roofs with traditionally framed or step down truss construction. Model AH56 Sprinkler Components and Dimensions Figure 8 1-5/8' • Deflector (41 mm) ��' Fusible Link no IM= Ell =tip 4'NjA.SI 046.,_...r, J, 'm Wrench Flat 2 5/16 � � r—J (59 mm) Threads — �r Model AH56 Minimum Required Flow and Residual Pressure Table Ceiling Slope Max.Coverage Area Flow Pressure ft x ft(m x m) gpm (I/min) psi(bar) 4:12 to 8:12 10 x 15*(3.0 x 4.6) 15(57) 7.2(0.50) *Long dimension of coverage area to be along the roof slope. Coverage is 6'-0"(1.8m)toward the peak and 9'-0" (2.7m)toward the eave from the sprinkler. Coverage area to be measured parallel to the floor. Note:The first row of AH sprinklers may be a maximum of 9'-0"from the eave; however,the first row must always be on the eave side • of the girder truss(see Figures 24 and 25). Bulletin 056 Page 9 of 27 March 2021 Reliable www.reliablesprinkler.com Model DD Series Sprinkler-Example Layout(Not to Scale) Figure 9 • Model DD Series Sprinkler(Typ.) _ Ncige II-- —11 Eave — ' Calculation Requirements: Wet System-Most demanding five(5)DO Series Sprinklers Dry System-Most demanding seven(7)DC Series Sprinklers Model DS56 Sprinkler-Example Layout(Not to Scale) Figure 10 111 Model DS56- Sprinkler(Typ.) Pogo V Draft Gorton or Walt - - - rave-- Calculation Requirements: Wet System-Most demanding five(5)DS56 Sprinklers Dry System-Most demanding nine(9)DS56 Sprinklers • Bulletin 056 111I Page 10 of 27 March 2021 www.reiiablesprinkler.com Model DD Series Sprinklers at Ridge with Model DS56 Sprinklers Beyond Obstruction Figure 11 Example Layout(Not to Scale) • Model DD Series Sprinkler(Tye.) 1 F 11' -Obstruction(not necessarily / full length ol space) —nutgE,72,4sow ,,=t-zstatati7 Model DS56 Sprinkler to protect- -0. w SE i behind obstruction(Required .s E .E when coverage area exceeds 15') Eav Calculation Requirements: Wet System-Most demanding live(5)DD Series Sprinklers and two(2)D856 Sprinklers Dry System-Most demanding seven(7)DD Series Sprinklers and two(2)DS56 Sprinklers Model DS56 Sprinklers at Ridge with Model DS56 Sprinklers Beyond Obstruction Figure 12 1111 Example Layout(Not to Scale) Eave Model DS56 Sprinkler(Typ) t 1 Ridge Draft Curtain or Wee' ' ; -Obstruction(not necessarily • full length of space) Model DS56 Sprinkler to protect ' 7 behind obstruction(Required when coverage area exceeds 15') Eave Calculation Requirements: Wet System-Most demanding five(5)DD Series Sprinklers and two(2)DS56 Sprinklers Dry System-Most demanding seven(7)DD Series Sprinklers and two(2)DS56 Sprinklers Bulletin 056 11110:111 Page 11 of 27 March 2021 www.reliablesprinkler.com Model DD Series Sprinklers at Ridge with Model GP56 or AH Series Sprinklers Beyond Obstruction Figure 13 Example Layout(Not to Scale) Eave ►.,. • Model DO Series.i. Sprinkler(Typ.) i edge ._. if 1 ll I') 4 ,;.' -ik 6' if -- 31 It S 71 I. Model GP56 or AH Series i, Obstruction(not necessarily Sprinkler to protect behind ‘ :' full length of space) obstruction(maximum 15' between obstruction and 1 • -_-- ' 2 r1-'=« == `n +s= e,M,Z gMeg cave) s s o '>: �.. a `.r Eave . --_ Calculation Requirements: Wet System-Most demanding five(5)DD Series Sprinklers and two(2)GP56 or AR Series Sprinklers Dry System-Most demanding seven(7)DO Series Sprinklers and two(2)GP56 or AH Series Sprinklers Model DS56 Sprinklers at Ridge with Model GP56 or AH Series Sprinklers Beyond Obstruction EMO Example Layout(Not to Scale) Model DS56- Sprinkler(Typ) \ _ adge 7 Nan Curran or Well, - Model GP56 or AH Series ,Obstruction(rot necessarily Sprinkler to protect behind '-- - -- lull length of space) obstruction(maximum 15' between obstruction and - --- -_ — - cave) �- T yr., = = x Eave ...- Calculation Requirements: Wet System-Most demanding five(5)DS56 Sprinklers and two(2)GP56 or AH Series Sprinklers Dry System-Most demanding seven(7)DS56 Sprinklers and two(2)GP56 or AH Series Sprinklers • Bulletin 056 Page 12 of 27 March 2021 REM www.reliablesprinkler.com Model DD Series Sprinklers at Ridge with Model GP56 or AH Series Sprinklers in Dormers Figure 15 Example Layout(Not to Scale) • Model DD Series(or Model DS56)Ridge Sprinkler , Averframed area(Lower / trusses may be completely or partially sheathed) ,j f fr hr° N.; d 1 6r •' Model DD Series(or Model-' DS56)Ridge Sprinkler • ' r Dormer , i s T 1Sr .,. $ r • --Model AH Series or _ ",. ` GP56 Sprinklers _... .,i, , z. Calculation Requirements Where Attic and Dormer Spaces are NOT Separated': Wet System-Most demanding five(5)ridge sprinklers and two(2)AH Series or Model GP56 sprinklers when there are four(4) sprinklers or less in dormer.When more than four(4)AH Series or GP56 sprinklers in dormer,separately calculate(a)five(5) ridge sprinklers and(b)all AH Series or Model GP56 sprinklers in dormer(up to a maximum 1500 square foot area)and use the greater of the two demands. Dry System-Most demanding seven(7)ridge sprinklers and two(2)AH Series or GP56 sprinklers when there are four(4) sprinklers or less in dormer.When more than four(4)AH Series or Model GP56 sprinklers in dormer separatetycalculate(a) seven(7)ridge sprinklers and(b)all AH Series or Model GP56 sprinklers in dormer(up to a maximum 1950 square foot area), and use the greater of the two demands. 'Note:Where attic and dormer spaces are separate,compartmentalized areas,the combined ridge sprinkler and dormer sprinkler calculation is not required. • Bulletin 056 Reliable Page 15 of 27 March 2021 www.reliablesprinkler.com Model DD Series Sprinklers at Ridge with Standard Spray Sprinklers at Dormer or Cross Figure 16 Example Layout(Not to Scale) mood (Sr Mode • D5SB)Ridge Spookier -- vedramed area(Lower y'n{ o? /Trusses may be completely or gf7 - / partially sheathed) -- /9:: f; 1�'� / / \ r / / \ Model DD Sores la Maki' _ DSeel n%ge SprinIder j it (d�ym \� unuuip FdlaliD \ { D) ; I -Dormer \. 900319) -- -- j .A i:,9 1p / / 9etr11,7 C - - •/ Ai I� _ A • `..- Standard Spray Sponkers ®ta 11413 Calculation Requirements When Attic and Dormer Spaces are NOT Separated': Wet System-Most demanding five(5)ridge sprinklers and two(2)standard spray sprinklers when there are four(4)sprinklers or less in dormer.When more than lour(4)sprinklers in dormer,separatelycalculate the most demanding remote area,including all sprinkler types,per NFPA 13,and use the greater of the two demands.30%remote area increase to sloped ceiling is required,and remote area reduction for use of quick response standard spray sprinklers may be appkcable. Dry System-Most demanding seven(7)ridge sprinklers and Iwo(2)standard spray sprinklers when there are four(4)sprinklers or less In dormer.When more than four(4)sprinklers in dormer,separatety calculate the most demanding remote area, including all sprinkler types,per NFPA 13,and use the greater of the two demands.30%remote area increase for sloped ceiling and 30%remote area increase for dry system is required. 'Note:Where spaces are separate compadmentalized areas,calculate the ridge sprinklers per figures 9 or 10,and the dormers per NFPA 13,and use the greater of the two demands. • Bulletin 056 Page 14 of 27 March 2021 www.reliablesprinkler.com Model DD Series Sprinklers at Ridge with Model DD Series Sprinklers in Dormers Figure 17 Example Layout(Not to Scale) • .Model DO Series or Model DS56 / Sprinkler(Typ.) Lave .---- i ir ill : I il ' 1 Model DD Series or Model D556� III : Sprinkler(Typ.) : l i t 11 i i i I I ( I 1 ; : I 1 1 a� :i ` ; r : . � , ' i , l iii • , , i ' I i il . I . .Eave Calculation Requirements Where Attic and Dormer Spaces are NOT Separated': Wet System-Most demanding five(5)Model DD Series or DS56 sprinklers at ridge plus up to two(2)sprinklers in dormer Dry System-Most demanding seven(7)Model DD Series or DS56 sprinklers at ridge plus up to two(2)sprinklers in dormer 'Note:Where attic and dormer spaces are separate,compartn kntalized areas,refer to Figures 9 or 10. Model DD Series Sprinklers at Ridge with Model GP56 or AH Series Sprinklers at Eave Figure 18 • Example Layout(Not to Scale) Note:if necessary,a baffle a a s a. a y m m 5 may be added between the Model DD sprinklers and the Model GP56 sprinklers to prevent cold solder. Model DD Series Sprinkler(Typ.) ' roaee—► It ,II It 1I k L' r —I ft 1 I II di tl Model GP56 Sprinkler or. Model AH Series Sprinkler to extend ridge sprinkler protection(maximum 15' coverage area) NL, z av T `T' m `s Calculation Requirements: Wet System-Most demanding five(5)DD Series Sprinklers and Iwo(2)GP56 or AH Series Sprinklers . Dry System-Most demanding seven(7)DD Series Sprinklers and two(2)GP56 or AH Series Sprinklers Bulletin 056 Page 15 of 27 March 2021 www.rehablesprinkleccom Model DS56 Sprinklers at Ridge with Model GP56 or AH Series Sprinklers at Eave Figure 19 Example Layout(Not to Scale) Eave Note:if necessary,a baffle may be added between the s I Model DS sprinklers and the Model GP56 or AH Series sprinklers to prevent cold solder. Model DS56. Sprinkler(Typ.) ♦ W � A T A_. All4 7, A. 4 Ridge .1 8 e '11 & e' 'r I k '6 y' Draft Contain or Wei' Model GP56 Sprinkler or Model AH Series Sprinkler to extend ridge sprinkler protection(maximum 15' `. coverage area) ~T- '+v- 'r Eave-..-.- Calculation Requirements: Wet System-Most demanding five(5)DS56 Sprinklers and two(2)GP56 or AH Series Sprinklers Dry System-Most demanding seven(7)055E Sprinklers and two(2)GP56 or AH Series Sprinklers • Model DD Series Sprinklers at Ridge with DS56 Sprinklers at Hip or Ell Figure 20 Example Layout(Not to Scale) Ali nip ► -.• —Ell `'Drell Curler or Wal(Tyy.) Model DS56 2 Model DS56 Sprinkler lTyp _. Sprinkler rryp.l .;� __. ". a ... _. Curlain or Well(Typ).,l, Calculation Requirements: Wet System-Most demanding live(5)Model DD Series and/or DS56 4) N.', • sprinklers R Model DD Sew, Dry System-Most demanding nine(9)Model DD Series and/or DS56 sp5nkkrDrip.) sprinklers;of which only a maximum of seven(7)must be Model DD Series(ridge)sprinklers Bulletin 056 Page 16 of 27 March www.reliablesprinkler.com ww.reliablesprinkler.c.com Model DS56 Sprinklers at Ridge with DS56 Sprinklers at Hip or Ell Figure 21 Example Layout(Not to Scale) i IIII/ Hi. I : : — --Ell "kali Curtain or Well(Typ I Model DS56'' ii:ill'll .'. , : : l : E'rn'lrl Sprinkler ITyp.) 30drilder(Typ.) '41 fa-50) (a.z I „ D .,11)1 rliier ....._ Vi.s R4)) aros, yt t itl : : : t(t,,,.„ Craft Culein or Wal(Tylk1 / 06.,, ,ssigl 11:laciat Atekligi V ' / 11.011E1 a.'ift )itpa a.E troo a.161 Calculation Requirements: i.gio.0 .•mi., -- - --- Wet System-Most demanding Ilve(5)Model DS56 sprinklers .r--r-,Irrrtr, i "-Draft Cumin on was(Typ.) Dry System-Most demanding nine(9)Model 0856 sprinklers orr, t-,-r' Rage,' Model DD Series Sprinklers at Ridge with Standard Spray Sprinklers at Hip or Eli Figure 22 Example Layout(Not to Scale) • -- -FI \ \ I 1•••• , ` -Priciest shaded area atth standard spray sprinklers in sconscance sth NEPA 13 \ , _iro.Eihr.! . , Cri.i[wl roalt ,,, : ittmcm19 'Protect shaded area with liftioli slanders spay sprinklers in accordance with NEPA-3 k111) s-Model DO Series huge *jotter 1Typ.) Calculation Requirements When Attic and Hip or ElI Spaces are NOT Separated*: Wet System-Most demanding live(5)ridge sprinklers and two(2)standard spray sprinklers when there are lour(4)sprinklers or less in the hip or ell.When more than four(4)sprinklers in hip or ell,separataycalculate the most demanding remote area, including all sprinkler types,per NFPA 13,and use the greater of the two demands.30%remote area increase for sloped III ceiling is required,and remote area reduction for use of quick response standard spray sprinklers may be applicable. Dry System-Most demanding seven(7)ridge sprinklers and two(2)standard spray sprinklers when there are four(4)sprilklers or!ens in hip or ell.When more than four(4)sprinklers in hip or ell,separately calculate the most demanding remote area, including all sprinkler types,per NFPA 13,and use the greater of the two demands.30%remote area increase for sloped ceiling and 30%remote area increase for dry system is required. Bulletin 056 Page 17 of 27 March 2021 Reliable www,reliablesprinklencorn Model DS56 Sprinklers at Ridge with Standard Spray Sprinklers at Hip or Ell Figure 23 Example Layout(Not to Scale) 7--trr Ell ,rotect shaded area with standard spray spdnIdars In accordance wit NEPA I3 r:s! ird V - - - - e.41 01. .utri A•ile • co.EN -Pron-cl shaded area with standard spray sprinkleN in accordance 01101 NFPA 13 4.; ) Modal ESE& Oratt Curtain or Wall(IA>) %wider(Tsp./ Calculation Requirements When Attic and Hip or EN Spaces are NOT Separated*: Wet System-Most demanding five(5)ridge sprinklers and two(2)standard spray sprinklers when there are four(4)sprinklers or less in the hip or ell.When more than four(4)sprinklers in hip or ell,separate/ycalculate the most demanding remote area, including all sprinkler types,per NFPA 13,and use the greater of the two demands.30%remote area increase for sloped ceiling is required,and remote area reduction for use of quick response standard spray sprinklers may be applicable. Dry System-Most demanding seven(7)ridge sprinklers and two(2)standard spray sprinklers when there are tour(4)sprinklers or less in hip or ell.When more than four(4)sprinklers in hip or ell,sepacate6rcalculate the most demanding remote area, Including all sprinkler types,per NFPA 13,and use the greater of the two demands.30%remote area increase for sloped • Bulletin 056 Page 18 of 27 March 2021 www.reliablesprinkler.com Model DD Series Sprinklers at Ridge and Model AH Sprinklers at Hip and Ell Figure 24 Example Layout(Not to Scale) • f .- Model AH42 or AH56 Sprinkler ,�, \ �� a Sea Note A, a ,_ Note:Minimum 2'-0"lateral �, cr, See Note A offset required between ! / qp sprinklers when viewed up 1 the roof slope. IT I 11. f1 ti IL 1 (II Di 1 L d , - a� 2, i / 14i1B . HI Note:First row of AH sprinklers - -� __ -Mpdel A ( yp)s ' P S rinkler T may be a maximum of 9'-0"from eave;however,must be on eave F 1 , side of girder truss. -Model DD Series Ridge, Sprinkler(Typ.) • Calculation Requirements: Wet System-Most demanding five(5)Model DD Series ridge sprinklers and two(2)AH sprinklers when there are four(4)AH sprinklers or less.When more than four(4)AH sprinklers,separate/ycalculafe(a)five(5)Model DD Series ridge sprinklers and two(2)AH sprinklers,and(b)all AH sprinklers(up to a maximum 1500 square foot area)and use the greater of the two demands. Dry System-Most demanding seven(7)Model DD Series ridge sprinklers and two(2)AH sprinklers when there are four(4)AH sprinklers or less.When more than four(4)AH sprinklers,separate/ycalculate(a)seven(7)Model DD Series ridge sprinklers and two(2)AH sprinklers,and(b)all AH sprinklers(up to a maximum 1950 square foot area)and use the greater of the two demands. Note A: A single quick-response standard spray upright sprinkler installed in accordance with NFPA 13 may be used for the protection of small areas outside the coverage areas of the specific application attic sprinklers.Demand for the single sprinkler shall be added to the calculations listed above if it falls within the 1500 sf wet system or 1950 sf dry system design area.CPVC piping on wet pipe systems is permitted for supplying individual quick-response standard spray upright sprinklers installed in this manner. • Bulletin 056 Reliable Page 19 of 27 March 2021 www.reliablesprinkler.com Model DS56 Sprinklers at Ridge and Model AH Sprinklers at Hip and Ell Figure 25 Example Layout(Not to Scale) -:,• ..-- :a. al . . , • . Model AH42 or AH56 Sprinkler,. ..,,-,1 • Note:Minimum 2'-0"lateral- .,. 4... : ,. .,-r.' ,See Note A -...,......, ',.,„:„, . offset required between sprinklers when viewed up the roof slope. & & & & iV & & „ -, - =, = See Note A / .„=Ca C3= r r / €-, / / Hi -Model AH Series Note:First row of AH sprinklers er-- -.... ' Sprinkler(Typ.) may be a maximum of 9'-0"from eave;however,must be on eave r, side of girder truss. / ' -'._model DS56 Ridge&Draft Curtain or Wale Sprinkler(Typ.) Calculation Requirements: Wet System-Most demanding five(5)Model DS-56 Series ridge sprinklers and two(2)AH sprinklers when there are four(4)AH sprinklers or less.When more than four(4)AH sprinklers,separate/ycalculate(a)five(5)Model DS-56 Series ridge sprinklers and two(2)AH sprinklers,and(b)all AH sprinklers(up to a maximum 1500 square foot area)and use the greater of the two demands. Dry System-Most demanding seven(7)Model DS-56 Series ridge sprinklers and two(2)AH sprinklers when there are four(4)AH sprinklers or less.When more than four(4)AN sprinklers,separate/ycalculate(a)seven(7)Model DS-56 Series ridge sprinklers and two(2)AN sprinklers,and(b)all AH sprinklers (up to a maximum 1950 square foot area)and use the greater of the two demands. NOB A: A single quick-response standard spray upright sprinkler installed in accordance with NFPA 13 may be used for the protection of small areas outside the coverage areas of the specific application attic sprinklers.Demand for the single sprinkler shall be added to the calculations listed above if it falls within the 1500 sf wet system or 1950 sf dry system design area.CPVC piping on wet pipe systems is permitted for supplying individual quick-response standard spray upright sprinklers installed in this manner. • Bulletin 056 RIM Page 20 of 27 March 2021 www.reliablesprinkler.com Model AH Series Sprinklers at Ridge and DS56 Sprinklers in Attic(Plan View) Figure 26 • Eays ► Model DS56 Sprinkler(Typ.) Model AH ,'1 , } n, m, r Sprinkler(Typ.) Ridge— +• t Ct� Draft Curtain or WalF • Eave----► Calculation Requirements: Wet System-Most demanding five(5)sprinklers of either type Dry System-Most demanding nine (9)DS56 Sprinklers or(7)AH Series Sprinklers Model AH Series Sprinklers at Ridge and DS56 Sprinklers in Attic(Cross Section) Figure 26A 1"min Model AH Series or 12"max. standard spray sprinkler within 12"of ridge line Wall or Draftln Model DS56 sprinkler Curtain Max. 7'-6" Model AH Series Sprinklers used in this arrangement shall have the deflector oriented flat(parallel to the floor),and the frame arms parallel to the ridge line (i.e.,frame window opening toward eaves). Coverage area, flow and pressure requirements,and obstruction rules for AH Series sprinklers to be in accordance with pages 8 and 9 of this bulletin. • Reference NFPA 13 when using standard spray sprinklers at peak. Bulletin 056 reliable Page 21 of 27 March 2021 www.reliablesprinkler.com Obstruction Criteria Figure 27 Model DD Series sprinkler Model DD Series sprinkler Min.gap above Obstruction • 150max. obstruction greater than 6" ( mm) 3-1/2'(90 mm) 6"(150 mm)in height obstruction height Obstruction Obstruction Additional sprinkler beyond obstruction Additional sprinklers not reauired due to obstruction 6" (150 mm)or less Additional sprinklers reauired beyond obstruction greater than 6" (150 in height with a minimum 3-1/2"(90 mm)gap provided between the top of mm) in height or where a minimum 3-1/2" (90 mm) gap is not provided the obstruction and the roof deck between the top of the obstruction and the roof deck. Model DS56 sprinkler Model DS56 sprinkler Min.gap above Obstruction 6" 150 mm max. obstruction Obstruction ( ) 3-1/2"(90 mm) greater thanri i obstruction height ` 6"(150 mm)in height Additional sprinkler iFlr Obstruction I�Ir�`beyond obstruction 11 I Additional sprinklers not required due to obstruction 6"(150 mm)or Additional sprinklers required beyond obstruction greater than 6" (150 less in height with a minimum 3-1/2"(90 mm)gap provided between mm) in height or where a minimum 3-1/2" (90 mm) gap is not provided the top of the obstruction and the roof deck. between the top of the obstruction and the roof deck. Model DD Series sprinkler Model DD Series sprinkler ►` Horizontal obstruction Horizontal obstruction • �_� Additional sprinklers below horizontal obstruction Max.4'-0"(1.2 m)width Greater than 4'-0"(1.2 m)width • Additional sprinklers not reauired below horizontal obstruction 4'-0" Additional sprinklers required below horizontal obstruction greater than (1.2 m)or less in width. 4'-0"(1.2 m)in width. Model DD Series sprinkler Model DO Series sprinkler Horizontal obstruction Horizontal Less than 6"(150 mm)from Min.6'(150 mm)from horizontal obstruction obstruction horizontal obstruction to bottom of rafter to bottom of rafter Additional sprinkler beyond obstruction Additional sprinklers not required beyond horizontal obstruction more than Additional sprinkler reauired beyond horizontal obstruction less than 6" 6"from bottom of rafter (150 mm)from bottom of rafter. Additional sprinkler not required beyond vertical obstruction(see figure at left)where: W 0 Obstruction width,W Minimum distance between T sprinkler and obstruction,D 1"or less(25 mm or less) 6"(150 mm) 7 1"to 4"(25 to 100 mm) 1'-0"(300 mm) 4"to 8"(100 to 200 mm) 2'-0"(600 mm) D 8"to 10"(200 to 250 mm) 5'-0"(1.5 m)f--- 111 . 10"to 20"(250 to 500 mm) 10'-0"(3.0 m) 20"to 30"(500 to 750 mm) 15'-0"(4.5 m) 30"to 40"(750 to 1000 mm) 20'-0"(6.0 m) 40"to 48"(1000 to 1200 mm) 25'-0"(7.5 m) Provide sprinklers beyond vertical obstructions not meeting the criteria above. 11111 Bulletin 056 Rellabld Page 22 of 27 March 2021 www.reliablesprinkler.com Obstruction Criteria(cont.) Figure 28 • Model DD Series sprinkler Less than 3'-0'(900 mm) Less than 3'-0'(900 mm) Min.3'-0'(900 mm) to t'-0'(300 mm) to 1'-0'(300 mm) clearance between clearance between - clearance between • closed space and enclosed space enclosed space ..... Idtiiiiihk.. .....N. roof deck and roof dec IIM : d roof deck Intermediate level J ) Intermediate level sprinklers sprinklers Additional sprinklers not required beyond enclosed space more than 3-0" beyond enclosed space beyond enclosed space 1900 mm from roof deck. Additional intermediate level sprinklers required beyond enclosed space less than 3'-0'(900 mm)to 1'-0"(300 mm)from roof deck. • • Less than 1'-0'(300 mm) Less than 1'-0"(300 mm) clearance between clearance between enclosed space enclosed space and root deck ..).- Elantl roof deck Additional sprinklers Additional sprinklers beyond enclosed space beyond enclosed space Additional sprinklers required beyond enclosed space less 1'-0"(300 mm) from roof deck. • Min.1'47(300 mm) Less than l'-0'(300 mm) Less than 70%open area deflector to top of stiffener Min.70%o en area �r P deflector to top of stiffener r Stiffener(Typ.) • IPP � Stiffener(Typ.) �its— -Additional sprinklers /� - - - below stiffeners(TYp.) Max.7-1/2' 1"r mm) Min.1'4 (300mm) Greater than 7-/2'(190 mm) Less than 1-0'(300 mm) '.. stiffener width gaps between stiffeners stiffener width gaps between stiffeners Additional sprinklers not required below stiffeners meeting all of the following Additional sprinklers required below stiffeners:(1)less than 1'-0'(300 mm) criteria:(1)minimum 1'-0"(300 mm)below Reliable Attic sprinklers,(2) below Reliable Attic sprinklers,(2)more than 7-1/2"(190 ram)wide stiffeners, maximum 7-1P2"(190 mm)wide stiffeners,(3)minimum 1'-0"(300 mm)gaps (3)gaps between stiffeners are less than 1'-0"(300 mm),or(4)where the area between stiffeners,and(4)minimum 70%open area. of the horizontal plane where the stiffeners are located is less than 70%open. Note: Reliable Attic sprinklers may be installed directly on pipe up to 2-1/2" NPS. For 3" NPS and larger pipe, Nominal 1.1/2"(38 mm) the obstruction rules for Extended Coverage Upright / maximum gap Spray Sprinklers shall be followed. i ''''' N....---... i N. Alternate Allowable Framing Method A maximum 1-1/2 in(38 mm)gap between sheathing and top of structural framing members(such as that formed by nailers laid flat)is acceptable, Bulletin 056 Page 23 of 27 March 2021 Reliable www.reliablesprinkler.com Installation Install Reliable Attic Sprinklers only in the orientation indicated in Figure 28. Figure 29 provides additional select installation criteria for each sprinkler model. • Installation Orientation Figure 29 Installation Dimensions Figure 30 Model DD Series Model DD Series Max.6"(150 mm)horizontally from center of sprinkler to ridge mcg Install Model DD Series sprinklers with the deflector parallel to the 17'(430 mm)min. floor and arrows on deflector pointing down the roof slope in both directions. to 21"(530 mm)max. top of deflector Model DS56 below peak, ridge,or deck Model DS56 • Min.30"(762 mm)to max.42"(1067 mm) horizontally from draft curtain or wall to deflector Install Model DS56 sprinklers with the frame arms perpendicular Min.9"(230 mm)to max.13"(330 mm) to the roof deck(parallel with lower eave) and the arrow on the top of deflector to roof deck • deflector pointing down the roof slope. I ' Min.8"(200 mm) Model GP56 and AH Series top of deflector above bottom of draft curtain Model GP56 9 ° Min. 9"(230 mm)to max. 13"(330 mm) top of deflector to roof deck Install Model GP56 sprinklers with the deflector parallel to the roof deck and the arrow on the deflector pointing down the roof slope. Install Model AH Series sprinklers with the deflector parallel to the roof,and frame arms parallel with the lower eave of the protected space. Model AH42/AH56 Min. 1"(25 mm)to max. 3"(76 mm) >r, top of deflector to bottom of truss top chord 11110 Bulletin 056 Re Page 24 of 27 March 2021 www.reliablesprinkler.com Note:Where Reliable Attic Sprinklers are installed on wet-pipe sprinkler systems with CPVC pipe,the CPVC pipe must be protected in accordance with the pipe manufacturer's installation instruction as well as the requirements in Figure 30. • Installation Requirements for Use of Reliable Attic Sprinklers with Listed CPVC Pipe Figure 31 �j> CPVC Pipe Min.18" /3 1 (450 mm) Heat producing j or releasing device Maintain at least 18" (450 mm)between CPVC pipe and heat producing or releasing devices. Max. 1'-0" Offset(A)must not exceed 6"(150 mm) (300 mm) A ^ irect Mount 'Angled Sprig 1' Armover Sprig 1 Vertical Sprig CPVC Riser i Install sprinklers on CPVC pipe only in the following configurations: (1)directly mounted to a fitting on the branch line pipe, (2)on an angled sprig where the horizontal distance between the sprinkler and the branch line does not exceed 6" (150 mm), (3) on an armover sprig where the horizontal distance between the sprinkler and the branch line does not exceed 6" (150 mm), or (4) on a Locate a sprinkler within 1'-0" (300 mm) horizontally of CPVC vertical sprig. risers • Model GP56 or AH _ Max..3-f Series sprinkler Model GP56 sprinkler (900 mm)7 —Angled sprig �+ - Noncombustible—\\ U _Min.6"(150 mm) Noncombustible Max. 10'-0" Vertical sprig insulation insulation \ (3 m) Min.6"(150 mm) (e.g.,fiberglass) (e.g.,fiberglass)Joist x. Joist ) Min. 1'-0" Min.1'-0" Min. -0" M 1'-0 in. " I (300 mm) I (300 mm) 7 1' — (300 mn) 't 00 mm) f Branch lines over joists must be protected with a minimum 6"(150 Branch lines over joists must be protected with a minimum 6"(150 mm) thickness of noncombustible insulation (e.g., fiberglass). A mm) thickness of noncombustible insulation (e.g., fiberglass). A maximum of 3'-0"(900 mm)of an angled sprig may extend above maximum of 10'-0" (3 m)of a vertical sprig may extend above the the insulation to supply Model GP56 and AH Series sprinklers. insulation to supply Model GP56 sprinklers. i —! Model GP56 or AH %i Model GP56 or AH / Series sprinkler "Series sprinkler Max.3'-0" g Max.3'-0" p (900 mm)_\' Angled sprig (900 mm)_ Angled sprig Noncombustible—, Min.6"(150 mm) Noncombustible —Min.6"(150 mm) insulation \ r, insulation (e.g.,fiberglass) (e.g.,fiberglass) Joist---___ � Joist-- �( Branch lines between joists must be protected with a Branch lines between joists must be protected with a minimum 6" (150 mm) thickness of noncombustible minimum 6" (150 mm) thickness of noncombustible insulation (e.g., fiberglass) either within the joist bay or on insulation (e.g., fiberglass) either within the joist bay or on top of the joists.A maximum of 3'-0"(900 mm)of an angled top of the joists.A maximum of 3'-0"(900 mm)of an angled • sprig may extend above the insulation to supply Model sprig may extend above the insulation to supply Model GP56 and AH Series sprinklers. GP56 and AH Series sprinklers. Bulletin 056 ';ab'2 Page 25 of 27 March 2021 C� www.reliablesprinkler.com Installation Requirements for Use of Reliable Attic Sprinklers with Listed CPVC Pipe Figure 32 Model GP56 sprinkler �-Model GP56 sprinkler Vertical sprig Vertical sprig Noncombustible—\ Max.10'-0" Max.10'-0" insulation \ (3 m) Min.6'(150 mm) -Min.6"(150 mm) Noncombustible (3 m) (e.g.,fiberglass) insulation I1UTi1IIJoist (e.g.,fiberglass) Joist Branch lines between joists must be protected with a minimum Branch lines between joists must be protected with a minimum 6" (150 mm) thickness of noncombustible insulation (e.g., 6" (150 mm) thickness of noncombustible insulation (e.g., fiberglass) either within the joist bay or on top of the joists. A fiberglass) either within the joist bay or on top of the joists. A maximum of 10'-0" (3 m) of a vertical sprig may extend above maximum of 10'-0" (3 m)of a vertical sprig may extend above the insulation to supply Model GP56 sprinklers. the insulation to supply Model GP56 sprinklers. Model AH Series / ' ---Model AH Series F sprinkler } sprinkler Vertical sprig Vertical sprig Any r Amy Length Length Noncombustible Insulation Noncombustible Min.6"(150 mm) Min.6"(150 mm) (e.g.,fiberglass) insulation ismo (e.g.,fiberglass) Joist `I Mln.P-0" I Min.1'-0" Joist 7(300 mm)) I"(300 mm) !'� Branch lines over joists must be protected with a minimum 6" Branch lines over joists must be protected with a minimum 6" (150mm)thickness of noncombustible insulation(e.g.,fiberglass). (150mm)thickness of noncombustible insulation(e.g.,fiberglass) A vertical sprig of any length may extend above the insulation to either within the joist bay or on top of the joists. A vertical sprig of supply Model AH Series sprinklers. any length may extend above the insulation to supply Model AH Series sprinklers. Caution: 1. Insulation required by Figures 30 and 31 is for fire protection ------Model AH Series purposes and not for freeze protection. sprinkler 2. Follow installation requirements of the CPVC pipe Vertical sprig manufacturer and listing,including vertifying compatibility of Any � any insulation or other materials used with CPVC pipe. Length 3. Sprig ups to Model GP56 and AH Series sprinklers must be Noncombustible- --Min.6"(150 mm) properly secured and supported in accordance with NFPA 13 insulation requirements. (e.g.,fiberglass) Joist Branch lines over joists must be protected with a minimum 6" (150mm)thickness of noncombustible insulation(e.g.,fiberglass) either within the joist bay or on top of the joists. A vertical sprig of any length may extend above the insulation to supply Model AH Series sprinklers. • Bulletin 056 e1� Page 26 of 27 March 2021 �ab�� www.reliablesprinkler.com Installation Maintenance Model DD Series,Model GP56,and Model AH Series sprinklers Reliable Attic sprinklers should be inspected and the sprinkler • are installed with the W2 wrench. The Model DS56 wrench is system maintained in accordance with NFPA 25,as well as the used to install Model DS56 sprinklers. The use of any other requirements of any Authorities Having Jurisdiction. wrench to install Reliable Attic sprinklers is not permitted and Prior to installation, sprinklers should remain in the original may damage the sprinkler. Place the specified wrench over cartons and packaging until used. This will minimize the the sprinkler until the wrench engages the wrench flats. Do potential for damage to sprinklers that could cause improper not wrench any other part of the sprinkler assembly. Tighten operation or non-operation. the sprinkler into the fitting after applying a PTFE based thread sealant to the sprinkler's threads. Recommended installation Do not clean sprinklers with soap and water, ammonia liquid or torque is specified in Table J. any other cleaning fluids. Remove dust by gentle vacuuming without touching the sprinkler. Installation Torque Table J Replace any sprinkler which has been painted (other than Recommended factory applied). Replace any sprinkler which has been Installation Torque damaged. A stock of spare sprinklers should be maintained to Sprinkler Threads (min.—max.) allow quick replacement of damaged or operated sprinklers. ft-lb N-m Failure to properly maintain sprinklers may result in inadvertent /z NPT or IS07-1R1/2 8-18 11-24 operation or non-operation during a fire event. 3/4"NPT or ISO7-1 R3/4 14-20 19-27 Listing &Approval Agency Do not exceed the maximum recommended torque. Exceeding Underwriters Laboratories, Inc. and UL Canada(cULus) the maximum recommended torque may cause leakage or impairment of the sprinkler.Use care when placing or removing Listing Category: Sprinklers,Automatic and Open the wrench from the sprinkler to avoid damage to the sprinkler. Guide Number: VNIV, VNIV7 Installation Wrenches Figure 33 Guarantee Model W2 Wrench For the Reliable Automatic Sprinkler Co., Inc.guarantee,terms, • and conditions,visit www.reliablesprinkler.com. Ordering Information +' Specify the following when ordering. Sprinkler For Models DD56,DD80,GP56,AH42,and AH56 sprinklers • Model(DD56-6, DD56-27, DD80-6, DD80-27, DS56, GP56,AH42,AH56) • Threads(NPT or ISO 7-1) Model DS56 Wrench Sprinkler Wrench • Model W2(for Model DD Series, Model GP56, and r 3 x Model AH Series sprinklers) r< { • Model DS56(for Model DS56 sprinklers) For Model DS56 sprinklers rn v 0 rn rn rn rn rn Z d Bulletin 056 Page 27 of 27 March 2021 Re1iable www.reliablesprinkler.com Bulletin 006 June 2021 R ® Model RFC Series Residential SprinklersFlat Concealed Pendent • cULus Listed Features • cULus Listed as Residential Sprinklers • Push-On cover plate installation • Low water flow requirements z Product Description Pi, illModel RFC Series residential sprinklers are flat cover plate, concealed pendent sprinklers intended for installation in Model RFC30&RFC3OLL Model RFC43&RFC43LL accordance with NFPA 13, NFPA 13R,or NFPA 13D.The sprinklers are cULus Listed as Residential Sprinklers in accordance with UL 199. In addition, Model RFCLL Series sprinklers are cULus Certified for Health Effects to NSF/ANSI .. standard 61 Annex G (LL)and Australian WaterMark Certified =€ ' (WMCS). • Model RFC30 sprinklers have a 165°F(74°C)temperature 1 — rated fusible-link operating element. Model RFC43, RFC49, RFC58, and RFC76 sprinklers are offered with either a 165°F ' (74°C)or 212°F(100°C)temperature rated fusible-link • operating element.Sprinklers with a 165°F(74°C)temperature Model RFC49&f VC49LL ; Model RFC58 rating are ordinary temperature classification and are listed A VIP for use with a 135°F(57°C)temperature rated cover plate. Sprinklers with a 212°F(100°C)temperature rating are intermediate temperature classification and are listed for use -;;Z:, ,—, ,,, All with a 165°F(74°C)temperature rated cover plate. Model RFC Series sprinklers are installed with a Model G5 cover plate. Model G5 cover plates are installed by pushing the cover plate into the cup and turning in the clockwise direction _.1111111 until it is tight against the ceiling. Model RFC30, RFC3OLL, • RFC43, RFC43LL, RFC49 and RFC49LL sprinklers allow 1/2" (13 mm)of cover plate adjustment. Model RFC58 and RFC76 ' sprinklers allow 3/4"(19 mm)of cover plate adjustment. Model Model RFC76 Model G5 Cover Plate G5 cover plates are available in a variety of finishes as listed in Table H. Table A S rinkler Model Nominal K-Factor Max.Coverage Area Listings& Sprinkler Identification P gpm/psil"2(I/min/bar") ft x ft(m x m) Approvals Number(SIN) RI-C30 3.0(43) 14 x 14(4.3 x 4.3) " , cULuc RAOC11 RFC3OLL 3.0(43) 14 x 14(4.3 x 4.3) cULus, LL,WMCS RA3211 RFC43 4.3(62) 20 x 20(t3.1 x 6.1) c.ULus RAud-rt RFC43LL 4.3(82) 20 x 20(6.1 x 6.1) L.ULus, LL,WMCS RA3212 RFC49 4.9(71) 20 x 20(6.1 x 6.1) cULus RA0616 • RFC49LL 4.9(71) 20 A 20(0.1 x 0.1) uULus, LL,WMCS RA3210 RFC58 8(84) 20 x 20(8.1 x 6.1) t ULua RAOO 13 RFC7G 7.G(100) 20 A 20(6.1 A G.1) cULus RAOC 10 cULus:cULus Listed to UL199,Automatic Sprinklers for Fire-Protection Service. LL:cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G(Less than 0.25%Lead content). WMCS:Australian WaterMark Certified. www.reliablesprinkler.com K odel RFC30 & RFC30LL Residential Sprinklers RFC30: SINRA0611 RFC3OLL: SINRA3211 Techni. I Specifications Sensitivity Style:F F. Concealed Pendent Fast-response 1 . Threads: "NPT or ISO 7-1 R1/2 Nominal K- - tor:3.0(43 metric) Temperature Rating ... Max.Working essure: 175 psi(12 bar) 165°F(74°C)sprinkler Min.Spacing:8 2.4 m) 135°F(57°C)cover plate Material Specification. Cover Plate Thermal Sensor:Nicke 'Iloy Solder Link Model G5 Cover Plate Sprinkler Body:Brass All. Levers:Bronze Alloy Sprinkler Wrench '-,-."--_ ' Yoke:Brass Alloy Model FC(without wrench-able cap) Sealing Assembly:Nickel Alloy PTFE Model W3(with wrench-able cap) Load Screw:Bronze Alloy Towers:Copper Alloy Listings and Approvals Pins:Stainless Steel cULus Listed to UL 199 Deflector:Bronze Alloy cULus Certified for Health Effects to NSF/ANSI s ` Cup:Steel Standard 61 Annex G(RFC30LL only) Bottom View ,` Watermark Certified(RFC30LL only) Cover Plate Finishes (See Table H) Model RFC30&RFC30LL Sprinkler Components and b• ensions Figure 1 2-5/16" H. (58 mm) Threads— N. Cup Dia. Body—� N — L- Cup _ —W , f:_��. O -- � L _2-58"(67 mm) • Tower 1-3/4"(44 mm)+/-1/4"(6 m a- ; � Hole in Ceiling Fusible Link Nominal face of fitting to ceilin. r I. 3/16" Deflector(retracted) -•- 1 il.= -•-•- -_ �� 1 „ �(Smm) 0:V 60'-° CAI Pin(extended) Yi ri Deflector(extended)� ,F- 3-5/16" Model G5 Cover Plate (84 mm) \ Ceiling Dia. Model RFC30 and RFC30LL Sprinkler Hydraulic Design Criteria Table B Minimum Flow and Residual Pressure t't Max.Coverage Area(2) Flow Pressure ft.x ft. gpm psi (m x m) (I/min) •ar) 12 x 12 9 9.1 (3.6 x 3.6) (34) (0.62) 14 x 14 10 11.0 (4.3 x 4.3) (38) (0.76) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of:(1)the flow listed in Table B above and(2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. • Bulletin 006 Ref— Page 2 of 8 June 2021 www.reliablesprinkler.com Model RFC43& RFC43LL Residential Sprinklers RFC43: SINRA0612 RFC43LL: SINRA3212 Techn :I Specifications Sensitivity • Style: I Concealed Pendent Fast-response Temperature Rating .& Threads: 2"NPT or ISO 7-1 R1/2 Nominal K- :ctor:4.3(62 metric) Ordinary: Max.Workin• •ressure: 175 psi(12 bar) Spacing: 2.4 m 165°F(74°C)sprinkler Min.S P 9 ( ) 135°F(57°C)cover plate Intermediate: Material Specificatio it Thermal Sensor:Nick- Alloy Solder Link 212°F(100°C)sprinkler 165°F(74°C)cover plate Sprinkler Body:Brass A •y Levers:Bronze Alloy Yoke:Brass Alloy Cover Plate - Sealing Assembly:Nickel Allo ith PTFE Model G5 Cover Plate Load Screw:Bronze Alloy Towers:Copper Alloy Sprinkler Wrench Pins:Stainless Steel Model FC(without wrench-able cap) Deflector Bronze AlloyModel W3(with wrench-able cap) 3'� ,+� Bottom View , z to 4 Cup: Steel Listings and Approvals Cover Plate Finishes cULus Listed to UL 199(See Table H) cULus Certified for Health Effects to NSF/ANSI „ Standard 61 Annex G(RFC43LL only) Watermark Certified(RFC43LL only) Model RFC43&RFC43LL Sprinkler Components an• 4 imensionsIIIME 2-5/16" Threads - (58 mm) - Cup Dia. Body • Cup �� _ - l< Tower 2 5/6'(67 mm) ( )+/-1/4" • mm) Hole in Ceiling " 1-3/4" 44 mm fitting to c:'Ing � i Fusible Link Nominal face of " , 3/16" Deflector(retracted) ����. (5 mm) Pin(extended) °°"F'°°`°'`° _ i ri 1 Deflector(extended)--- -*-- 7 , 3-5/16" Model G5 Cover Plate (84 mm) Ceiling Dia. Model RFC43&RFC43LL Sprinkler Hydraulic Design Criteria Table C Minimum Flow and Residual Pressure 0) Ordinary Temperature Inte ediate Temperature Max.Coverage Area(2) ft.x ft. Flow Pressure Flow Pressure (m x m) gpm psi gpm psi (I/min) (bar) (I/min) (bar) 15x15 12 7.8 12 7.8 (4.6 x 4.6) (45) (0.54) (45) (0.54) 16 x 16 13 9.1 13 9.1 (4.9 x 4.9) (49) (0.63) (49) (0.63) 18 x 18 18 17.5 -- (5.5 x 5.5) (68) (1.21) 20 x 20 21 23.8 (6.1 x 6.1) (79) (1.64) fallotes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of:(1)the flow listed in Table C above and(2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. Bulletin 006 Rella6le Page 3 of 8 June 2021 www.reliablesprinkler.com Model RFC49 & RFC49LL Residential Sprinklers RFC49: SINRA0616 RFC49LL: SINRA3216 Technical Specifications Sensitivity Style:Flat Concealed Pendent Fast-response Y a Threads: 1/2"NPT or ISO 7-1 R1/2 m" „i..�, Nominal K-Factor:4.9(71 metric) Temperature Rating Max.Working Pressure: 175 psi(12 bar) Ordinary: - `• Min.Spacing:8 ft.(2.4 m) 165°F(74°C)sprinkler 135°F(57°C)cover plate ' Material Specifications to e•'ate ,;,•'" Thermal Sensor:Nickel Alloy Solder Link 212° (100°C sprinkler Sprinkler Body:Brass Alloy 165°F(74°C)cover plate .i Levers:Bronze Alloy44504, :: Yoke:Brass Alloy Cover Plate Sealing Assembly:Nickel Alloy with PTFE Model G5 Cover Plate Load Screw:Bronze Alloy Towers:Copper Alloy Sprinkler Wrench At). Pins:Stainless Steel Model FC(without wrench-able cap) Deflector: Bronze Alloy Model W3(with wrench-able cap) Bottom View Cup:Steel Listings and Approvals --` Cover Plate Finishes cULus Listed to UL 199 (See Table H) cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G(RFC49LL only) Watermark Certified(RFC49LL only) Model RFC49&RFC49LL Sprinkler Components and Dimensions Figure 3 2-5/16" (58 mm) Threads - Cup Dia. Body Cup �w 1 Tower 2-5/8"(67 mm) 1-3/4"(44 mm)+/-1/4"(6 mm) Hole in Ceiling Fusible Link Nominal face of fitting to ceiling '1i1411M �l I .11 3/16" Deflector(retracted) — (5 mm) Pin(extended) — i I ooeriuoi ox_a9 \ Deflector(extended) - ars=- 3-5/16" Model G5 Cover Plate (84 mm) —Ceiling Dia. Model RFC49&RFC49LL Sprinkler Hydraulic Design Criteria Table D Minimum Flow and Residual Pressure(1) Max.Coverage Area 12) Ordinary Temperature Intermediate Temperature ft.x ft. Flow Pressure Flow Pressure (m x m) gpm psi gpm psi (I/min) (bar) (I/min) (bar) 16x16 13 7.0 13 7.0 (4.9 x 4.9) (49.0) (0.48) (49.0) (0.48) 18 x 18 17 12.0 17 12.0 (5.5 x 5.5) (64.3) (0.83) (64.3) (0.83) 20 x 20 20 16.7 21 18.4 (6.1 x 6.1) (75.7) (1.15) (79.5) (1.27) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of:(1)the flow listed in Table D above and(2)the flow required to achieve a mini- mum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. Bulletin 006 Rel-abl� Page 4 of 8 June 2021 www.reliablesprinkler.com Midel RFC58 Residential Sprinkler SIN RA0613 Tec ical Specifications Cover Plate Finishes Style. lat Concealed Pendent (See Table H) Threa• •1/2"NPT or ISO 7-1R1/2 • Nominal Factor 5.8(84 metric) Sensitivity - Max.Works • Pressure: 175 psi(12 bar) Fast-response Min.Spacing. :ft.(2.4 m) I ' Temperature Ratings Material Specifica '•ns Ordinary: "* 't' Thermal Sensor:N, el Alloy Solder Link 165°F(74°C)sprinkler - Sprinkler Body:Bras- A Hoy 135°F(57°C)cover plate Levers:Bronze Alloy Intermediate: '`'' "). Yoke:Brass Alloy 212°F(100°C)sprinkler Sealing Assembly:Nickel A .y with PTFE 165°F(74°C)cover plate Load Screw:Bronze Alloy Towers:Copper Alloy Cover Plate Pins:Stainless Steel Model G5 Cover Plate Deflector:Chrome Plated Bronze Al • Cup:Steel Sprinkler Wrench Bottom View ,T..-:_.„:„.._ 4,". Model FC(without wrench-able cap) ( �• Model W3(with wrench-able cap) Listings and Approvals cULus Listed to UL 199 Model RFC58 Sprinkler Components and Dimens •ns Figure 4 2-5/16" Threads (58 mm) .. Cup Dia. Body �� — Cup - � [171-1F—H, • �`TowerFusible Link 1-7/8"(48 mm)+/-3/8"( m) / Hole in Ceiling Nominal face of fitting to c- 'ng Deflector(retracted) 3116" sa= r e i (5 mm) Pin(extended) II ht 0 081GO'" �' I H-'- Deflector(extended) -y 3-====__,,_-0 3-5/16" Model G5 Cover Plate (84 mm) Ceiling Dia. Model RFC58 Sprinkler Hydraulic Design Criteria Table E Minimum Flow and Residual Pressures" Max.Coverage Area(2) Flow Pressure ft.x ft. gpm psi (m x m) (I/min) (bar) 16 x 16 16 7.6 (4.9 x 4.9) (60.6) 53) 18 x 18 18 9.: (5.5 x 5.5) (68.1) (0.66) 20 x 20 20 11.9 (6.1 x 6.1) (75.7) (0.82) Notes: • 1. For NFPA 13 installations the flow per sprinkler must be the greater of:(1)the flow listed in Table E above and(2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. Bulletin 006 �eliable� Page 5 of 8 June 2021 www.reliablesprinkler.com Model RFC76 Residential Sprinkler SIN RA0618 Technical Specifications Cover Plate Finishes Style:Flat Concealed Pendent (See Table H) „- Threads:3/4"NPT or ISO 7-1 R3/4 • Nominal K-Factor 7.6(109 metric) Sensitivity Max.Working Pressure:175 psi(12 bar) Fast-response Min.Spacing:8 ft.(2.4 m) Temperature Ratings _ Material Specifications Ordinary: " Y _ "-, Thermal Sensor:Nickel Alloy Solder Link 165°F(74°C)sprinkler Sprinkler Body:Brass Alloy 135°F(57°C)cover plate Levers:Bronze Alloy Intermediate: Yoke:Brass Alloy 212°F(100°C)sprinkler a¢ Sealing Assembly:Nickel Alloy with PTFE 165°F(74°C)cover plate Load Screw:Bronze Alloy Towers:Copper Alloy Cover Plate Pins:Stainless Steel Model G5 Cover Plate ti: Deflector:Bronze Alloy Cup:Steel Sprinkler Wrench Bottom View ' k Model FC(without wrench-able cap) Model W3(with wrench-able cap) Listings and Approvals cULus Listed to UL 199 Model RFC76 Sprinkler Components and Dimensions Figure 5 2-5/16" Threads (58 mm) N Cup Dia. Body— Cu ' Tower i 1 i� 1-7/8"(48 mm)+/- ( )00-1 -MI j 2-5/8"(67 mm) Fusible Link 3/8" 9 mm 1 / Hole in Ceiling Nominal face of tilting to ceiling C , WAIN I� No i / Deflector(retracted) � 1 3/16" Pin(extended) 1 - — (5 mm) Deflector(extended) - t9 ====zsh.,6 } i 3-5/16" Model G5 Cover Plate (84 mm) -- Ceiling Dia. Model RFC76 Flat Concealed Sprinkler Hydraulic Design Criteria Table E Minimum Flow and Residual Pressure(li Max.Coverage Area(2) Flow Pressure ft.x ft. gpm psi (m x m) (I/min) (bar) 16 x 16 21 7.6 (4.9 x 4.9) (79.5) (0.52) 18x18 24 9.9 (5.5 x 5.5) (90.8) (0.68) 20 x 20 34 20 (6.1 x 6.1) (128.7) (1.4) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of:(1)the flow listed in Table E above and(2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. • Bulletin 006 Reliable Page 6 of 8 June 2021 www.reliablesprinkler.com Cover Plate Finishes()) Table H • Special Application Finishes • White Polyester Off White Paint c e Lack Paint Raw Brass Bright Brass a\° W&shed Bronze Black Plated Satin Chrome cpaPaStainless Steel CIad131 Custom Color Paints�) Notes: Qsd 1. Paint or any other coating applied over the factory finish will void all approvals and warranties. 2. Custom color paint is semi-gloss,unless specified otherwise. 3. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Allow on the back side.Cover plates are not listed or approved as corrosion resistant. Installation Dimensions Table J Recommended Min.to Min.to Max. Cover Cover Plate Cover Plate Max.Face Dropped Deflector Cover Plate Sprinkler Hole Diameter Plate Diameter Adjustment of Fitting to Distance below Temperature Model Model inch(mm) in Ceiling inch (mm) Ceiling1'1 Ceiling Rating inch(mm) inch (mm) inch (mm) RFC30, G5 1/2 1-1/2 to 2 1/2 to 1 135°F RFC30LL (84) (67) (13) (57°C) RfC43, 135°F12J RFC43LL, G5 3-5/16 2-5/8 1/2 1-1/2 to 2 1/2 to 1 (57°C) RFC49, (84) (67) (13) (38 to 51) (13 to 25) or 165°Fi31 RFC^9I I (74°C) RFC58, 3- 3/4 1-1/2 to 2-1/4 1/4 to 1 135°F(�)(57°C) RFC76 G5 (84) (67) (19) o 25 or 165°F3 (74°C) Notes: 1. Face of fitting to ceiling dimensions are based on a nominal thread make up.Verify dimensions based on fitting and thread sealing method prior to installation.A 1/2"x 1/2"brass nipple extension(Reliable P/N 6999991900)is available where necessary for replacement of existing sprinklers. • 2. For use with 165°F(74°C)temperature rated sprinklers where the maximum ceiling temperature does not exceed 100°F(38°C). 3. For use with 212°F(100°C)temperature rated sprinklers where the maximum ceiling temperature does not exceed 150°F(66°C). Installation Model RFC series sprinklers are intended to be installed in Note:When used with gasketed fittings,follow fitting accordance with NFPA 13, NFPA 13R,or NFPA 13D,as well as manufacturer's installation instructions regarding tightening to the requirements of applicable authorities having jurisdiction. achieve a leak-free connection. Model RFC series sprinklers must not be installed in ceilings with positive pressure in the space above. Ensure that the 4 slots in Do not exceed the maximum recommended torque. Exceeding the cup are open and unobstructed following installation. Model the maximum recommended torque may cause leakage or RFC series sprinklers are shipped with a wrench-able protective impairment of the sprinkler. Use care when inserting or removing cap that should remain on the sprinkler until the sprinkler system the wrench from the sprinkler to avoid damage to the sprinkler. is placed in service following construction. Install the cover plate by hand by pushing the cover plate into the Model RFC series sprinklers can be installed without removing cup and turning the cover in the clockwise direction until it is tight the wrench-able protective cap using the Model W3 wrench. against the ceiling. Alternatively, Model RFC series sprinklers can be installed using the Model FC wrench by temporarily removing the protective cap during installation of the sprinkler.The use of any other wrench to installed Model RFC series sprinklers is not permitted and may damage the sprinkler. Fully insert the Model W3 wrench over the cap until it reaches the bottom of the cup,or the Model FC wrench over the sprinkler until the wrench engages the body. Do not wrench any other part of the sprinkler/cup assembly.The Model W3 and FC wrenches are designed to be turned with a standard 1/2"square drive.Tighten the sprinkler into the fitting • after applying a PTFE based thread sealant to the sprinkler's threads. Recommended installation torque for iron pipe fittings is 8 to 18 ft-lbs(11 to 24 N-m)for 1/2"thread sprinklers and 14 to 20 ft-lbs(19 to 27 N-m)for 3/4"thread sprinklers. Bulletin 006 Page 7 of 8 June 2021 liieliabld www.reliablesprinkler.com Installation Wrenches • (DT- PIM 111.11 • Model FC Model W3 For use with Model RFC Series sprinklers For use with Model RFC Series sprinklers with without wrench-able cap installed wrench-able cap installed Service/Spare Head Cabinet Wrench Listings and Approvals Listed by Underwriters Laboratories, Inc.and UL Certified for Canada to UL 199,Automatic Sprinklers for Fire-protection Model W8 Service(cULus). High-strength plastic wrench for limited(emergency) Certified by Underwriters Laboratories, Inc.and Underwriters use with Model RFC Series sprinklers without wrench-able Laboratories of Canada for Health Effects to NSF/ANSI Standard • p 61 Annex G(LL) (RFC30LL, RFC43LL, and RFC49LL only). cap installed. Meets NFPA requirements for sprinkler • wrench on premises. Australian WaterMark Certified(RFC30LL, RFC43LL,and RFC49LL only). Patents Model RFC30, RFC30LL, RFC43, RFC43LL, RFC49, RFC49LL, RFC58,and RFC76 sprinklers are covered by U.S. Patent No. Maintenance 9,248,327 and U.S. Patent No.7,275,603. Model RFC series sprinklers should be inspected and the Model RFC30, RFC30LL, RFC43 and RFC43LL sprinklers are sprinkler system maintained in accordance with NFPA 25. Do additionally covered by U.S. Patent No. 8,776,903. not clean sprinklers with soap and water,ammonia or any other cleaning fluids. Remove dust by gentle vacuuming. Replace any sprinkler cover plate assembly which has been painted(other Ordering Information than factory applied)or damaged in any way.A stock of spare sprinklers should be maintained to allow quick replacement of Specify the following when ordering. damaged or operated sprinklers. Prior to installation,sprinklers should be maintained in the original cartons and packaging until Sprinkler used to minimize the potential for damage to sprinklers that would • Model(RFC30, RFC30LL, RFC43, RFC43LL, cause improper operation or non-operation. RFC49, RFC49LL, RFC58, RFC76) • Temperature Rating Guarantee Cover Plate • Model G5 • Temperature Rating For the Reliable Automatic Sprinkler Co., Inc.guarantee,terms, • Finish(See Table H) and conditions,visit www.reliablesprinkler.com. Sprinkler Wrench • Model FC • Model W3 • Model W8(Limited use) am am rn rn z n`- Bulletin 006 Page 8 of 8 June 2021 Reliable www.reliablesprinkler.com 31-1530 Terrace Glen: Residential Units Bulletin 935 July 2019 ® Model KRes Series Fusible Link • ' Residential Sprinklers For NFPA 13, NFPA 13R,and NFPA 13D Applications cULus Listed Features • cULus Listed Residential Sprinklers • Available in pendent and horizontal sidewall orientations ° *_ ..°a • Decorative recessed escutcheons available " ;, Product Description �'�.. ; '>. Model KRes Series sprinklers are residential pendent and hor- izontal sidewall sprinklers with a fusible link operating element. KRes30 Recessed Pende KRes49 Recessed Pendent A variety of K-Factors and recessed finish options are available as detailed in this Bulletin. The KRes Series sprinklers are specially engineered for fast thermal response to meet the requirements of UL 1626. They �-- are intended for installation in accordance with NFPA 13, 13R, r II and 13D. . Application ,lii,< ..i. The Model KRes Series sprinklers cULus Listed Residential KRes58 Recessed Penden KRes44 HSW Recessed sprinklers are intended for use in accordance with NFPA 13, Horizontal Sidewall NFPA 13R,or NFPA 13D.The Model KRes residential sprinklers • are cULus Listed for use in residential occupancies and resi- 1 dential portions of any occupancy, where permitted by NFPA 1 13, NFPA 13R,or NFPA 13D. For NFPA 13R and NFPA 13D ap- , plications, the design flow and pressure shall not be less than ,. _, the minimum flow and pressure specified in the Listed Design ){. Criteria tables in this Bulletin. For NFPA 13 applications,the de- ' '0~ sign density shall be a minimum of 0.1 gpm/sf (4.1 mm/min), ' , ? but in no case shall the flow and pressure be less than the min- `,, 1 °` imum flow and pressure specified in the Listed Design Criteria tables in this bulletin. Model KRes Series sprinklers are listed "s e for use in wet systems only. KRes58 HSW Recesse, KRes58 HSWX Recess- Horizontal Sidewall Horizontal Sidewall Residential Sprinkler Summary Table A Sprinkler Sprinkler K-Factor Thread Size Max.Coverage Area Model Identification Orientation gpm/psi z NPT or IS07-1 Installation Options ft x ft(m x Number(SIN) (Ipm/bar ) m) Kne590 '1'c,01 fbi.,loin 3.0(43) 1/2 r't, ,J ,t,. i,e,eeeed ,C A1C(4.9 A 4.a) Knes48 R3596 Pe^de^t 1.9(71) 1/2 Pondort or Aoeecced 20 x 20(6.1 x 6 1) 101-0 fi P3 03 R d „ 5.0(01) 1/9 F ,eJe,A e. Il„ee..seJ 20 r z0(G., .rt.,) KRes44 HSW RA3591 Horizontal Sidewall 4.4(63) 1/2 Sidewall or Recessed 16 x 20(4.9 x 6.1) Kn.550113W fld350'7 Iluiiz,x.lel'didewall 5.0(04) 1/2 OidewalI . Recessed 16 21914.9AS.,) '<'1:i 68"SW'Y rA60a I lorizontal Cidowall 6.8(C4) 11.! S:dc.+ell er roececeA 11 r G(1.3 x 7.0) • www.reliablesprinkler.com Model KRes30 SIN R3591 hnical Specifications Finishes S 4 e:Pendent (See Table H) Th --ds:1/2"NPT or ISO7-1 R1/2 Sensitivity Nomi I K-Factor.3.0(43 metric) -. Max.W. ing Pressure:175 psi(12 bar) Fast-response Temperature Ratings .,.... 165°F(74°C) b:« Material Speci ations(Ref-Fig.7) 212°F(100°C) Thermal Sensor. ickel Alloy fusible link Recessed Escutcheons Sprinkler Frame: : .ss Alloy F2 Recessed Button:Copper Alloy Sprinkler Wrenches ill Sealing Assembly:Nic-I Alloy with PTFE Model W2 ') Load Screw:Bronze Allo Model W1 (recessed) Deflector:Bronze Alloy Listings and Approvals = Lever:Stainless Steel cULus Strut:Stainless Steel Model KRes30 Sprinkler Drop Figure 1 I _ 2-1/4" 57mm) 'IA. ( Face of fitting to finished ceiling 1-15/16" 3/8"(9mm)+/- \(49mm) DIA.7-- 1/4"(6mm) -am. /72 / • 2-1/4" Illr j00 D "! Il (57mm) ''�i �l �"; -�, i i �I �� I��I 0 1-1/2"(38mm) +/- 1/4"(6mm) L.._ 1-1/8" 2-7/8"(72 )DIA. - (28mm) Dimension- F2 Recessed Escutcheo Installation Model KRes30 Sprinkler - draulic Design Criteria Table B Minimum Flow and Residual Pressure Max.Coy, age Area Flow GPM Pressure Deflector t. Ceiling Distance ft.x - (m x m) (Umin) PSI(bar) 1 12(3,6 x 3,6) 8(30,3) 7 (0,48) General 1 to , inches (25 to 100 ) 14 x 14(4,3 x 4,3) 10(37,8) 11 (0,76) F2 Escutcheon 1-1/4 to 1-3/4 inches 16 x 16(4,9 x 4,9) 13(49) 18.8(1,3) (31.7 to 44.4 mm) • Bulletin 935 www.reltablesprinkler.com Page 2 of 9 July 2019 .reliablesprinkler.com Model KRes49 SIN R3596 Tech ' al Specifications Finishes • Style: •endent (See Table H) Thread 1/2"NPT or IS07-1 R1/2 Sensitivity Nominal Factor.4.9(71 metric) Fast-response Max.Worki t Pressure:175 psi(12 bar) Temperature Ratings 165°F(74°C) Material Specifics'•ns(Ref.Fig.7) 212°F(100°C) Thermal Sensor:Ni. el Alloy fusible link Recessed Escutcheons Sprinkler Frame:Br--,Alloy F2 Recessed y Button:Copper Alloy Sprinkler Wrenches l' Sealing Assembly:Nicke 'Iloy with PTFE Model W2 Load Screw:Bronze Alloy Model W1 (recessed) Deflector:Bronze Alloy Listings and Approvals Lever.Stainless Steel cULUS -` Strut:Stainless Steel Model KRes49 Sprinkler Drop Figure 2 2-1/4"(57m' )y DIA. Face of fitting to finished -15/16" ( ceiling ' A9mm)DIA.(t 3/8"(9mm)+/- 1/4"(6mm) 114 2-1/4" lir1i o3_,va iii."1 001 N III li� ii,� (57mm) °' I11 1 � I I 1-1/2"(38mm)+/- i °�, 1/4"(6mm) ill 1 1 1-1l4" 2-7/8 72mm)DIA. (32mm) - Dimensions F2 Recessed Escub eon Installation Model KRes49 Sprinkler Hydraulic II-sign Criteria Table C Minimum Flow and Residual Pressure Ordinary Temp.Rating Intermediate Temp.Rating Max. Coverage Area (165°F/74°C) (212°F/100°C) Deflector to ft.x ft.(m x m) Flow Pressure Flow Pressure Ceiling Distance GPM(Umin) PSI(bar) GPM(L/min) PSI(bar) 12 x 12(3,6 x .,6) 13(49) 7 (0,48) 13(49) 7(0,48) Gene 111 to 4 inches 14 x 14 (4 x 4,3) 13(49) 7(0,48) 13(49) 7(0,48) (25 , 100mm) 16 x 1: (4,9 x 4,9) 13(49) 7(0,48) 15(56,8) 9.4(0,65) F2 Escu eon 1-1/4 to 1-3/4' ches 1: 18(5,5 x 5,5) 19(72) 15(1,0) 19(72) 15(1,0) (31.7 to 44.4 ) • 20 x 20(6,1 x6,1) 20 (75,7) 16.7 (1,14) 22(83,3) 20.2(1,39) B letin 935 . , Page 3. 9 duly 2019 - -'J C www.reliablesprinkler.co • Model KRes58 SIN R3593 Te• nical Specifications Finishes Sty -:Pendent (See Table H) Thre:•s:1/2"NPT or IS07-1 R1/2 Sensitivity • Nomin: K-Factor.5.8(84 metric) �; _,• ' Max.Wo 'ng Pressure:175 psi(12 bar) Fast-response �- Temperature Ratings r - 165°F(74°C) Material Specifi -lions(Ref.Fig.7) 212°F(100°C) Thermal Sensor. 'ckel Alloy fusible link Recessed Escutcheons Sprinkler Frame:Br• Alloy F2 Recessed "° " Button:Copper Alloy Sprinkler Wrenches Sealing Assembly:Nick.- Alloy with PTFE Model W2 Load Screw:Bronze Alloy Model W1 (recessed) Deflector:Bronze Alloy Listings and Approvals Leven Stainless Steel cULUs4.110. Strut:Stainless Steel Model KRes58 Sprinkler Drop Figure 3 2-1/4" mm) It A. Face of fitting to finished ceiling 1-15/16" 3/8"(9mm)+/- (49mm)DIA./ 1/4"(I6mm) II ° V8Il ,ii, ✓// 1 r ��// 1 • 2-1/4" .1i .. ��� iNi (57mm) 1 1/2"(38mm)+/ 1-1/4" - 2-7/8"(72 )DIA. - (32mm) Dimensions F2 Recessed Escutcheo, Installation Model KRes58 Sprinkler Hydra c Design Criteria Table D Minimum Flow and Residual Pressure Ordinary Intermediate Temp.Rating Temp.Rating Max. Coverage •rea (165°F/74°C) (212°F/100°C) Deflector to ft.x ft. (m m) Flow Pressure Flow Pressure Ce -ng Distance GPM(Umin) PSI(bar) GPM (L/ PSI (bar) min) 12 x 1 (3,6 x 3,6) 16(61) 7.6(0,53) 16(61) 7.6 (0,53) General 1 to • ' ches 14 14(4,3 x 4,3) 16(61) 7.6(0,53) 16(61) 7.6(0,53) (25 to 100m 6 x 16(4,9 x 4,9) 16(61) 7.6(0,53) 17(64,3) 8.6 (0,59) F2 Escutcheon 18 x 18(5,5 x 5,5) 19(72) 10.8(0,75) 19 (72) 10.8(0,75) 1-1/4 to 1-3/4 inches • 20x20(6,1 x6,1) 22(83,3) 14.4 (1,0) 23(87,1) 15.7 (1,08) (31.7 to 44.4 mm) t Bulletin 935 Page 4 of 9 July 2019 a www.reliablesprinkler.com Model KRes44 HSW SIN RA3591 Technical Specifications Finishes Style:Horizontal Sidewall (See Table H) Threads:1/2"NPT or IS07-1R1/2 Sensitivity Nominal K-Factor:4.4(63 metric) Fast-response Max.Working Pressure: 175 psi(12 bar) Temperature Ratings 165°F(74°C) r f Material Specifications(Ref.Fig.7) Recessed Escutcheons 4 Thermal Sensor Nickel Alloy fusible link F2 Recessed '"' ' Sprinkler Frame:Brass Alloy Sprinkler Wrenches x Button:Copper Alloy Model W2 {lr Sealing Assembly:Nickel Alloy with PTFE Model W1 (recessed) Load Screw:Bronze Alloy Listings and Approvals Deflector:Bronze Alloy Lever:Stainless Steel cULUs Strut:Stainless Steel Model KRes44 HSW/F2 Figure 4 1-3/4"(44mm) Face of fitting 3/6"(9mm) +/-1/4"(6mm) to finished wall +/-1/4"(6mm) r 2-1/2"(64mm) - u 2-1/4" 1-15/16" Top of Deflector Down from (57mm) (49mm) it Ceiling to be Either 4"to 6" DIA. DIA. iJumth "� (100 to 150 mm)or 6"to 12" (150 to 300 mm)Based on 5/16'J '1 1 Flow&Pressure Selection I (8mm) I , l Dimensions F2 Recessed Escutcheon Installation Model KRes44 HSW/F2 Sprinkler Hydraulic Design Criteria Table E Minimum Flow and Residual Pressure Ordinary Temp.Rating Max.Coverage Area (165°F/74°C) Deflector to ft.x ft. (m x m) Flow Pressure Ceiling Distance GPM(Umin) PSI(bar) 12 x 12(3,6 x 3,6) 12(45,4) 7.5(0,52) 14 x 14(4,3 x 4,3) 14(53,0) 10.2(0,71) 16 x 16(4,9 x 4,9) 16(60,6) 13.3(0,92) 4 to 6 inches 16 x 18(4,9 x 5,5) 18(68,1) 16.8(0,53) (100 to 150mm) 18 x 18(5,5 x 5,5) 20(75,7) 20.7(1,43) 16 x 20(4,9 x 6,1) 23(87,1) 27.9(1,89) 12 x 12(3,6 x 3,6) 14(53,0) 10.2 (0,71) 14 x 14(4,3 x 4,3) 16(60,6) 13.3(0,92) 16 x 16(4,9 x 4,9) 17 (64,4) 15.0(1,04) 6 to 12 inches 16 x 18(4,9 x 5,5) 20(75,7) 20.7(1,43) (150 to 300 mm) 16x20 (4,9x6,1) 23(87,1) 27.4(1,89) Jul 2019 Reliable `i'e 0 - Y www.reliablesprinkler.com Model KRes58 HSW SIN RA3503 Te ,nical Specifications Finishes Styl=•Horizontal Sidewall (See Table H) III Three• :1/2"NPT or ISO7-1 R1/2 Sensitivity Nomina -Factor.5.8(84 metric) Fast-response Max.Wor ' g Pressure:175 psi(12 bar) Temperature Ratings 165°F(74°C) Material Specific: ions(Ref.Fig.7) Recessed Escutcheons Thermal Sensor: ' kel Alloy fusible link F2 Recessed Sprinkler Frame:B . s Alloy Sprinkler Wrenches I,l"; Button:Copper Alloy Model W2 &' '' fr Sealing Assembly:Nicke •Iloy with PTFE Model W1 (recessed) Load Screw:Bronze Alloy Deflector:Bronze Alloy Listings and Approvals Lever:Stainless Steel cULUs Strut:Stainless Steel Model KRes58 HSW/F2 Figure 5 1-3/4"(• mm) ace of fitting 3/8"(9mm) +/-1/• (6mm) to nished wall +/-1/4•(6mm)— 'J� 2-1/2"(64mm) - Al i � - 2-1/4" Ili 5/ ." ( � , Top of Deflector Down from ' irl r Ceiling to be Either 4"to 6" (57mm) " m) lin y i (100 to 150 mm)or 6"to 12" • DIA. (150 to 300 mm)Based on 5/16" i i Flow&Pressure Selection (8mm) 1 Dimensions F2 Recessed Escutcheon I .tallation Model KRes58 HSW/F2 Sprinkle ydraulic Design Criteria Table F Minimum Flow and Residual Pressure Ordinary Temp.Rating(165°F/74°C) Max.Coverage Area Deflector to ft.x ft.(m x m) Flow GPM Pressure -iling Distance (Umin) PSI(bar) 12 x 12(3,6 x 4,6) 16 (60,6) 7.6(0,53) 14 x 14(4,. x 4,3) 18 (68,2) 9.7(0,69) 4 to 6 i .hes 16 x 16 •,9 x 4,9) 21 (79,5) 13.2(0,91) (100 to 150 " m) 16 x : (4,9 x 5,5) 25 (94,7) 18.6(1,28) 16- 20(4,9 x 6,1) 29(109,8) 25(1,73) 2 x 12(3,6 x 3,6) 22(83,3) 14.4(1,0) 14 x 14(4,3 x 4,3) 22(83,3) 14.4(1,0) 16 x 16(4,9 x 4,9) 26(98,4) 20.1 (1,39) 6 to 12 inches • 16 x 18(4,9 x 5,5) 31 (117,4) 28.6(1,97) (150 to 300 mm) 16x20(4,9x6,1) 33(124,9) 32(2,21) Bulletin 935 Reliable Page 6 of 9 July 2019 www.reliablesprinkler.com Model KRes58 HSWX Residential Sprinkler SIN RA3593r' Tec ical Specifications Finishes • Sty!, Horizontal Sidewall (See Table H) Threa••:1/2"NPT or ISO7-1 R1/2 Sensitivity Nomina -Factor:5.8(84 metric) Fast-response Max.Wo '' g Pressure:175 psi(12 bar) Temperature Ratings 165°F(74°C) Material Specific ions(Ref.Fig.7) Recessed Escutcheons ill ,.., Thermal Sensor. ' kel Alloy fusible link F2 Recessed Sprinkler Frame:Br..s Alloy Sprinkler Wrenches ; Button:Copper Alloy Model W2 Sealing Assembly:Nicke 'Hoy with PTFE Model W1 (recessed) Load Screw:Bronze Alloy Listings and Approvals Deflector:Bronze Alloy Lever:Stainless Steel cULUs Strut:Stainless Steel Model KRes58 HSWX Sprinkler Co •onents and Dimensions Figure 6 2-1/4"(57' m) Face of fitting 3/8"(9mm) +/-1/4" :mm) to finished wall +/-1/4"(6mm)y 3"(76mm) — / Top of Deflector Down From 2-1/4" 1-15/16" ,, 1' ,r 1 Ceiling to be Either 4"to 6' --- (57mm) (49m 4~- (100 to 150 mm)or 6"to 12" DIA. 1I' (150 to 300 mm)Based on • 5/16" Flow&Pressure Selection (8mm) I Dimensions F2 Recessed Escutche•. Installation Model KRes58 HSWX Sprinkler Hydraulic %esign Criteria Table G Minimum Flow and Residual Pressure Max. Coverage Area Flow Pressure Deflector to ft.x ft.(m x m) gpm (I/min) psi(bar) Ceiling Distance 18 x 20(5,5 x 6,1) 29(109) 25(1,72) 20 x 20(6,1 x 6,1) 30(114) 26.8(1,85) 16 x 22(4,9 x 6,7 33 (125) 32.4(2,23) 4 to 6 inches ( if to 150 mm) 16 x 24(4,9 x ,3) 38(144) 42.9(2,96) 14 x 26(4 . x 7,9) 42(160) 52.4(3,75) 18 x 20 ,5 x 6,1) 35(133) 36.4(2,5) 16 2(4,9 x 6,7) 38(144) 42.9(2,96) 6 to 12 inch-. 1: x 24(4,9 x 7,3) 42(160) 52.4(3,6) (150 to 300 mm • 14 x 26(4,3 x 7,9) 46(174) 62.9(4,34) e:For coverage area dimensions less than or between those listed above,use the minimum required flow for the next highest coverage :rea for which hydraulic design criteria are stated. Bulletin 935 Page 7 of 9 July 2019 ', www.reliablesprinkler.com Finishes Table H Standard Finishes Special Application Finishes Sprinkler* F2 Escutcheon Sprinkler* F2 Escutcheon • Bronzc Dra33 Bright Dra33 bright Draoo Dull Chromo Dull Chromc White Polyester White Polyester Dlaek IlAye.,t.,r Black Polyester -- -- Cuatom Color Polycotcr Cuotom Color P'olyootor -- -- CL.,ct,el.a.Niehel r'TIE -- *Note:Paint or any other coating applied over the factory finish will void all approvals and warranties. Components Figure 7 Threads ----___ ---_ ,,,,i Wrench Flat Thermal — hill COM 11111 Button &Sealing Sensor _ l• /Assembly Frame liil ���`— Strut & Lever Model W2 t, - Deflector Load Screw Model W 1 ., �, / "— —""' Maintenance Components Reliable Model KRes Sprinklers should be inspected and the p sprinkler system maintained in accordance with NFPA 25, 13, Note: Deflector varies by model 13D, and 13R,as well as the requirements of any Authorities Having Jurisdiction. • Installation Prior to installation, sprinklers should remain in the original Models KRes fire sprinklers are to be installed in accordance cartons and packaging until used.This will minimize the with NFPA 13, 13D,or 13R and as shown in this bulletin. For potential for damage to sprinklers that could cause improper recessed installations,the Model F2 recessed escutcheon is operation or non-operation. the only escutcheon to be used with the KRes sprinklers. Use Do not clean sprinklers with soap and water, ammonia liquid of any other recessed escutcheon will void approvals and or any other cleaning fluids. Remove dust by gentle vacuum- warranties. ing without touching the sprinkler. For installing Model KRes sprinklers, use only the Model W2 Replace any sprinkler which has been painted (other than sprinkler Wrench;for installing Models KRes Recessed Pen- factory applied)or damaged. dent and Sidewall sprinklers use only the Model W1 sprinkler wrench. Use of wrenches other than those specified may A stock of spare sprinklers should be maintained to allow damage these sprinklers. quick replacement of damaged or operated sprinklers. Installation of KRes sprinklers in a wall or ceiling will require a Failure to properly maintain sprinklers may result in inadver- hole diameter of 2-1/4" (57 mm)for F2 recessed escutcheons. tent operation or non operation during a fire event. Install KRes HSW sprinklers with a ceiling to deflector dis- tance that complies with the hydraulic design criteria tables in this bulletin.The flow arrow on deflector must point away from near wall and "Top" marking must face the ceiling. A'leak tight"sprinkler joint can be obtained with a torque of 8-18 ft-lbs(11 —24 N-m). Do not tighten sprinklers over maximum recommended torque. This may cause leakage or impairment of the sprinklers. • Bulletin 935 Rellabld Page 8 of 9 July 2019 www.reliablesprinkler.com Listings &Approvals Listed by Underwriters Laboratories Inc.and UL Certified for • Canada(cULus) Guarantee For Reliable Automatic Sprinkler Company guarantee, terms, and conditions,visit www.reliablesprinkler.com. Patents For patents applicable to products contained in this technical bulletin, please visit www.r-s.co Ordering Information Specify the following when ordering: Sprinkler • Model (See Table A) • Temperature Rating • Threads(NPT or ISO7-1) • Finish (See Table H) Escutcheon • Model F2 Recessed • Finish (See Table H) Note:A variety of surface mount escutcheons are also available; please refer to Reliable Technical Bulletin 204. • Sprinkler Wrench • Model W2(Pendent and HSW) • W1 (Recessed and Concealed) CID z CO CO CO Bulletin 935 Page 9 of 9 July 2019M6N www.reliablesprinkler.com 31-1530 Terrace Glen: Exterior Patios and Decks Bulletin 157April2020 OD ReHabli K5.6 (80 metric) 1 • Quick-Response, 2. t. n • . r. S . ray Sprinklers o ND O Features 1 1. Available in the following configurations: g4_ • Pendent with standard escutcheon *: • Pendent with Model HB extended escutcheon E • Pendent with Model FP recessed escutcheon t • Pendent with Model F1 recessed escutcheon • Concealed Pendent with Model CCP cover plate • Horizontal Sidewall with Standard escutcheon 1" P • Horizontal Sidewall with Model HB extended es Pendent PCi iJCi it/NB cutcheon (See Fig. 1) (See Fig. 2) • Horizontal Sidewall with Model FP recessed es Ip��mioriormorlimmior cutcheon (FM Standard Response) • Horizontal Sidewall with Model F1 recessed es- ` cutcheon (FM Standard Response) • Upright IN 2. Available with 1" NPT, IS07-1R1, 3/4" NPT, or IS07 • i ;; 1 R3/4 inlet fitting. 4- 0 -. 3. 3/4" NPT inlet fittings permit replacement of older 3/4" inlet dry sprinklers without changing to a larger sprin- kler fitting. ficcc33cd Fr r cndcn Concealed 4. Sprinklers, escutcheons, and cover plates are avail- (See Fig.3) ;•e g. • able in a wide variety of standard and special appli- cation finishes. 5. White polyester, black polyester, and Electroless Nickel PTFE (ENT) finish sprinklers are cULus Listed as Corrosion Resistant. 6. Available with cULus Listed 250 psi (17.2 bar) pres- sure rating for Dry Pendent and select HSW configu- -a rations. FM Approved for 175 psi (12 bar). Product Description Recessed F1 Penden Horizontal Sidewall Model F3QR56 Dry sprinklers are quick-response, stan- (See Fig.5) (See Fig.6) dard coverage sprinklers with a nominal K-Factor of 5.6(80 metric). Available in Dry Pendent, Dry Horizontal Sidewall, x-a: and Dry Upright configurations, Model F3QR56 Dry sprin- - klers all use a 3 mm glass bulb operating element. See the i Temperature Ratings table in this Bulletin for available tern- - perature ratings. Model F3QR56 Dry sprinklers are intended for installation on wet-pipe, dry-pipe, or preaction sprinkler 1 systems in accordance with NFPA 13, FM Property Loss I loi izo,ital Side•all kQ Recessed FP Prevention Data Sheets, and other applicable installation (See Fig. 7) \ Horizontal Sidcwal4 standards. •. Model F3QR56 Dry Pendent and Sidewall sprinklers are available with a variety of escutcheon options as illustrated , y in Figs. 1 through 3 and Figs.5 through 9. In addition,Model ' * F3QR56 Dry Pendent sprinklers are also available with the Model CCP conical concealed cover plate as illustrated in ,i. 'Y` Fig. 4. Available sprinkler, escutcheon, and cover plate fin- • ishes are identified in the Finishes table in this Bulletin. The Model F1 escutcheon, Model FP escutcheon, and ModelRI CCP cover plate are the only recessed escutcheons and cover plate listed for use with Model F3QR56 Dry sprinklers; {See Fig. 0) Upright the use of any other recessed escutcheon or cover plate (See Fig. 10) Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elms • • , -, 0 I - with Model F3QR56 Dry sprinklers will void all guarantees, existing 3/4"or IS07-1 R3/4 inlet dry sprinklers, but may also warranties, listings and approvals. be used in new installations. Inlet fittings are available with 1"NPT, ISO 7-1 R1,3/4"NPT, See the Available Configurations, Listings, and Approvals or IS07-1 R3/4 threads. Sprinklers with 3/4" NPT and 1307- table in this Bulletin for further information on Model F3QR5640 1 R3/4 inlet fittings are intended primarily for replacement of Dry sprinklers. Available Configurations, Listings, and Approvals Available Sprinkler Sprinkler Escutcheon or Listings and Inlet Identification Model Cover Plate Length Approvalsl'l Threads Number (See Figs. 1-9) (SIN) Standard 2" to 36" Esc .•-on (50 to 900 mm) HB Extended Escutcheon F1 Recessed cULus, NYC 3/4" NPT or Escutcheon 3-1/ " • 6" IS07-1R3/4 FP Recesses to 900 mm) Escu --on F3QR56 Dry / -%'" '• - - - R5714 Pendent i Standard 2" to 48" 41 Escutcheon (50 to 1200 mm sr. ,-..-s scutcheo 1" NPT F1 ece .ed cULus, FM, NYC or Escu eon 31/2" to48" IS07-1R1 • (90 to 1200 rpm FP "ece ed scutcheo CCP Cover Plate I andard 2" to 48" Escutc (50 to 1200 mm) HB Extended Escutcheon cULusi2i, NYCi2> 3/4" NPT F1 Recessed 3-1 " • 48" or IS07-1 R3/4 Escutcheon :• to 1200 mm) FP R- - ed F3QR56 Dry dip �• Horizontal 1 R5734 Sidewall Standard 2" to 48" ' Escutcheon (50 to 1200 mm)A cULusl2>,• 2) _.� :—`, FM , NYC cutcheon •!.' • 1200 mm) 1" NPT or ---- ed IS07-1R1 Escutcheon •" . cULusi2i, FP Recess-• ••o 1201 Mc30i, NYC12) r, :o --4" F3QR56 Dry N/A 5"to 48" cULus1�1 1" NPT or R5724 Upright (127 to 1200 mm) IS07-1 R1 (2 cULus Listing and NYC for Light Hazard and Ordinary Hazard only. (31 FM Approved for Light Hazard only. (41 Model F3QR56 Dry Horizontal Sidewall with Model F1 or Model FP recessed escutcheon are FM Approved as Standard Response. 2. Listing and Approval Agencies See the Available Configurations, Listings, and Approvals table in this Bulletin for listings and approvals applicable to each available configuration. • 1. Listed by Underwriters Laboratories, Inc. and UL Certified for Canada(cULus) 2. Certified by FM Approvals (FM) 3. Permitted in New York City based on UL Listing per Local Law 33/2007 (NYC) Technical Data Nominal K-Factor: 5.6 gpm/psi'12(80 L/min/bar'"2) Sprinkler Listing or Approval Deflector to Ceiling Distance Maximum Working Pressure F3QR56 Dry cULus, NYC See note below 250 psi(17.2 bar) Pendent FM See note below 175 psi(12 bar) 4"to6" 250 psi(17.2 bar) F3QR56 Dry cULus,NYC Horizontal Sidewall 4"to 12" 175 psi(12 bar) FM See note below 175 psi(12 bar) F3QR56 Dry Upright cULus See note below 175 psi(12 bar) Note: Deflector distance to be in accordance with applicable NFPA, FM, or other agency requirements. Information is provided only when additional clarification is necessary. Temperature Glass Bulb Color Sprinkler Cover Plate Maximum Ceil- Listings and Classification Temperature Rating Temperature Rating ing Temperature Approvals'" Orange 135°F(57°C) Ordinary 135°F(57°C) 100°F(38°C) cULus,FM,NYC Red 155°F(68°C) Intermediate Yellow 175°F(79°C) 165°F(74°C) 150°F(66°C) cULus,NYC Intermediate Green 200°F(93°C) 165°F(74°C) 150°F(66°C) cULus,FM,NYC None 225°F(107°C) cULus,FM(2),NYC High Blue 286°F(141°C) 165°F(74°C) 150°F(66°C) cULus, NYC • (')For listed and approved sprinkler,escutcheon,and inlet configurations see the Available Configurations,Listings,and Approvals table in this Bulletin. (2}High temperature classification is FM Approved with Standard and Model HB escutcheons only. Finishes4 Component Sprinkler Fscutcheon1't Cover Plate Bronze Braao"' Whito Paint Standard Finishes Whitc Polycator'°' Whitc Polycatcr Ch.. Chrome Chrome €1^stro'ess Nickai PTGFJ21 Type316 StaInte°s Seel Satin Ck•or^e Special Application Finishes Ri ci Polyostor42' Black Polyoctor $faeR rai et Cu0te,,,C l Parlrt Oalvui CUly Pulyealer CLalui nei CUIui Pulyeatcr Clack Plating 0'>Standard and Model HB escutcheons are supplied with both the can and escutcheon finished.Model Fl escutcheons are supplied with both the collar and escutcheon finished.Model FP escutcheons are supplied with the escutcheon finished;the cup is galvanized or stainless steel with no further finish. (2)cULus Listed as a Corrosion Resistant Sprinkler. (3>Brass finish available for standard,Model F1,and Model FP escutcheons only. ("Dry upright sprinkler available in standard bronze only. 411 3. Model F3QR56 Dry Pendent Sprinkler with Standard Escutcheon (SIN R5714) A"Dim. 2"to 48"(51mm to 1219mm)in 1/4"(6mm)increments for 1"connections or 2"to 36"(51mm to 914mm)in 1/4"(6mm)increments for 3/4"connections • III • -i' pp �_ , C i __ Ii System Fitting — � —�� ',, Inlet Fitting 2 1/8" --.1 "A" Dimension [54mm] Dia Hole in Ceiling 1-1/4" Sprinkler Can [32 mm] I / Escutcheon / Adjustment ; / /—Escutcheon I / 15/32" / [12mm] 1 / Ceiling Nominal Escutcheon Position— w. 1/4" [6 mm] 1 a/8 • Escutcheon Adjustment [41 mm] 1/4"1/4" [6 mm] ' 1 Nom nal Protrusion 3" [76 mm] COMDRYDET1 DIA. Fig. 1 Note:The sprinkler can protrudes Y"when escutcheon is in nominal position. Escutcheon adjustment provides-'/"(-6mm)to+11/4" (+32mm)"A" dimension adjustment range. Sprinkler Guard: Model C2 • 4. odel F3QR56 Dry Pendent Sprinkler with Model HB Extended Escutcheon (SIN R5714) Dim. 31"to 48"(89mm to 1219mm)in 1/4"(6mm)increments for 1"connections or 31/2'to 36"(89mm to 914mm)in 1/4"(6mm)increments for 3/4"connections • i il, 11 - III} LI' L ! : _‘1--- , System tee ► Inlet fitting "A" Dimension 2-1/2" [4! mm] Dia. Hole in ‘HIing I 1/2" [13mrn] Escutcheon Adjustment i I Ceiling 1 1 /4 / [32mm] Nominal Position Escutcheon of Escutcheon Sprinkler Can ID 1/2" [13mm] Escutcheon Adjustment to ' C) COMDRYDET2 1 3-1/2" ► [89 mm] Escutcheon ?ia. Fig.2 Note: The sprinkler can protrudes 1Ya"when escutcheon is in nominal position. Escutcheon adjustment provides'Y2"(-12.7mm)to+Y2"(+12.7mm) "A"dimension adjustment range. Sprinkler Guard: Model C2 • 5. odel F3QR56 Dry Pendent Sprinkler with Model FP Recessed Escutcheon (SIN R5714) "Dim. 3V2"to 48"(89mm to 1219mm)in 1/4"(6mm)increments for 1"connections or 31/2"to 36"(89mm to 914mm)in 1/4"(6mm)increments for 3/4"connections r Z • d q q li iiiiii I I In': 1 2____L41 ___j L__ ____/ ij 1_ 31 1 Li \ _. 1 _ System Tee i N. Inlet Fitting 2-5/8"[67 mm] Dia. ■ "A"Dimension Hole in Ceiling Sprinkler / Cup 1/4" [6mm] , • Escutcheon Adjustment Escutcheon ' • Ceiling- c ? / 3/4" [19 mm] Nom. Nominal J/ Escutcheon Position 3 7/32" 1/4"[6 mm] Escutcheon Adjustment [82 mm] Dia. — COMDRYDET3 Fig.3 Note:Do not install the Model F3QR56 Dry Pendent sprinkler with the Model FP escutcheon in ceilings which have positive pressure in the space above. • 6. Model F3QR56 Dry Pendent Sprinkler with Model CCP Cover Plate (SIN R5714) "A"Dim. 31/2"to 48"(89mm to 1219mm)in 1/4"(6mm)increments for 1"connections or 3/z"to 36"(89mm to 914mm)in 1/4"(6mm)increments for 3/4"connections • r-L _- s1 I I I Fill If aP — I I1 ! III I I i 11 I mil I I l'''''' I lj 1 ' L-I - '-J ` System Tee -- —1 Inlet Fitting 2-1/2" [64 mm] Dia. I "A" Dimension Hole in Ceiling I 1 Sprinkler Cup / • 3/16" [5 mm] / Model CCP 1/2 Cover Plate Adjustment Cover Plate Assembly Ceilinglrul p r,°t j__T' � i /,( A / 7 22 m mm] Nominal Cover--J Plate Position 3/16" [5 mm] Cover Plate Adjustment 3-5/16" [84 mm] Dia. COMDRYDET4 Fig. 4 Note:Do not install the Model F3QR56 Dry Pendent sprinkler with the Model CCP cover plate in ceilings which have positive pressure in the space above. • 7. Model F3QR56 Dry Pendent Sprinkler with Model F1 Recessed Escutcheon (SIN R5714) "A"Dim. 3'/2"to 48"(89mm to 1219mm)in 1/4"(6mm)increments for 1"connections or 31/2"to 36"(89mm to 914mm)in 1/4"(6mm)increments for 3/4"connections. • r,._ s n�--� I----4II-II-- -, `i 1 Ili 1 1 , 1 if l I a II 1 ' i- 1 P I ii ii I I 1 i 1 1111,�1I, I Ls-� I ' J System Tee Inlet Fitting 2-1/4" [57 mm] Di.. I J Hole in Ceiling "A" Dimension / Collar / 1/4" [6 mm] Escutcheon Adjustment 1/8" 1 I IL , eiling [3 mm] Nominal Escutcheon / \ i \ Position I\ Escutc -on 1/4" [6mm] Escutcheon Adjustment 2-27/32" [72 mm] Dia. COMDRYDET5 Fig. 5 • 8. Model F3QR56 Dry Horizontal Sidewall Sprinkler with Standard Escutcheon (SIN R5734) "A"Dim. 2 to 48"(51mm to 1219mm)in 1/4"(6mm)increments for 1"connections or 2"to 36"(51mm to 914mm)in 1/4"(6mm)increments for 3/4"connections • Ceiling 4" [102 mm] Min. 12"[305 mm] Max. -f 15/32" [12mm] Sprinkler Can—, 2-3/32" ), System Fitting I [53 mm] ~ —Inlet Fitting I 7 5/8" [16 mm] 1- 4f — — - --- 3� \ [76 mm] 1 /2-1/8" - [54 mm] Dia. \—1/4"[6mm] Nominal Protrusion Hole in Wall L f- 1/4" [6 mm] • COMDRYDET6 • N. Escutcheon Adjustment 1-1/4"[32 mm] —Nominal Escutcheon Position Escutcheon Adjustment "A"Dimension Fig.6 Note:The sprinkler can protrudes Y4"when escutcheon is in nominal position. Escutcheon adjustment provides-14"(-6mm)to+11/4" (+32mm)"A" dimension adjustment range. • 9. odel F3QR56 Dry Horizontal Sidewall Sprinkler with Model HB Escutcheon (SIN R5734) aim 3'/2"to 48"(89mm to 1219mm)in 1/4"(6mm)increments for 1"connections or 31/2"to 36"(89mm to 914mm)in 1/4"(6mm)increments for 3/4"connections • Ceiling 4" [102mm] Min. Escutcheon 12"[305mm] Max. Sprinkler Can _ 2 3/32" \ System Tee -Inlet ' [53mm] 'rig / \ - - ��� 518"[16mm] 3-1/2° f [89mm] Escutcheon Dia. 2 1/2" Dia. 11 Hole [64 in Wall 1-1/4"[32mm] Nominal Protrusion [32mm] 1/2"[13mm] Escutcheon Adjustment • COMDRYDET7 1/2" [13mm] Nominal Position Escutcheon of Escutcheon Adjustment "A"Dimension Fig. 7 Note: The sprinkler can protrudes 11/4"when escutcheon is in nominal position. Escutcheon adjustment provides 1/2"(-12,7mm)to+1/2"(+12.7mm) "A"dimension adjustment range. • 10. 1 odel F3QR56 Dry Horizontal Sidewall Sprinkler with Model FP Recessed Escutcheon(SIN R5734) „A •im 31/2"to 48"(89mm to 1219mm)in 1/4"(6mm)increments for 1"connections or 31/2"to 36"(89mm to 914mm)in 1/4"(6mm)increments for 3/4"connections • Ceiling I .- Nom. A n 1-1/4" Escutcheon \ 1 [32 mm] i ° 4"[102 mm]Min. Sprinkler Cup �� cULus,NYC:6"[152 mm]Max. 7 System Tee FM: 12"[305 mm]Max. Inlet Fitting i- ��- \�� � �[ 5/8"[16 mm] `�I _ II l 11 i - - - - III , \\\ /, rl ‘ ` LyL--, III 3-7/32" _,-- [82 mm] Dia. 2-1/2 [64 mm] Dia. Hole in Wall 1/4"[6 ' ] Escutcheon A. , tment III • COMDRYDETB 1/4"[6 mm] _ \ Nominal Escutc -on Position Escutcheon Adjustment "A"Dimension - Fig. 8 I Note:Do not install the Model F30R56 Dry Horizontal Sidewall sprinkler with the Model FP escutcheon in walls which are positively pressurized with respect to the protected space. • 11. •del F3QR56 Dry Horizontal Sidewall Sprinkler with Model F1 Recessed Escutcheon (SIN R5734) „A„ ,.In. 3V2"to 48"(89mm to 1219mm)in 1/4"(6mm)increments for 1"connections or 31"to 36"(89mm to 914mm)in 1/4"(6mm)increments for 3/4"connections • Ceiling •' Nom. 1-3/4" 1/8" [44 mm] Escutcheon [3 mm] 4"[102 mm]Min. ••Ilar ,\ cULus,NYC:6"[152 mm] Max. System Tee \ N FM: 12"[305 mm]Max. Inlet Fitting --\ -_ -1! u' �` 1 —mil 5/8"[16mm] i l ` ‘' %?zrzi ��� 2-27/32" _,z__—,__1 [72 mm] Dia. 2-1/4"[57 mm]Dia. Hole in Wall 1/4"[6 mm] Escutcheon Adjust = t • N, Nominal Position COMDRYDET9 1/4"(6 mm] of Escutcheon Escutcheon Adjustment "A"Dimension Fig.9 • 12. Model F3QR56 Dry Upright(SIN 5724) Order Dimensions 5"to 48"(127 mm to 1219 mm) • i �' . , 4 ,) Note: Customer is responsible i for determining correct i deflector distance below structure above. Order I Dimension Inlet Fitting • �z + System Tee r- --i h _�, COMDRYDET10 i I s i i': i � � i1Ll Fig. 10 • 13. MINIMUM EXPOSED BARRE_ LENGTH WHEN CONNECTED TO WET PIPE SPRINKLER SYSTEM NOTE: STANDARD DRY PENDENT IS SHOWN, HOWEVER, MINIMUM EXPOSED BARREL LENGTH • APPLIES TO ALL STYLES OF DRY SPRINKLERS CONNECTED TO A WET PIPE SYSTEM. WAFT PIPE EXPOSED BARREL \ F1 J, AMBIENT AMBIENT TEMPERATURE _ TEMPERATURE 40T i4'C 50'F/10'C 60'F/15'C �N-.1�a--y^---f---_r-. --+(, EXPOSED TO - --Iryry1II---1---'-Illlll -'I DISCHARGE END , ��� __ EXPOSED MINIMUM BARREL LENGTH** 1I OF SPRINKLER`(FACE OF FITTING TO TOP OF CEILING)"" `1' -.<IF--'_ . L--,1... IN.(MM) IN_(MM) IN. (MU) L�-1 = X 40'F(4'C) 0 0 0 - " IP HUMIDITY AND TEMPERATURE DIFFERENTIAL 30T (-1"C) 0 0 D / CAUSES CONDENSATION ON THE EXPOSED DRY SR , CONSIDER WRAPPING THE EXPOSED 20'F (-I-C) 4 (100) 0 0 BAARRELREL WITH INSULATION. FOAM INSULATING TAPE OR EQUIVALENT. TOE (-12-C) 8(200) I (25) 0 1 55(-18'C) 12(300) 3(75) 0 MINIMUM (HEATED AREA) SEAL THE CLEARANCE SPACE EXPOSED AROUND THE SPRINKLER TO AVOID -ID'F (-23"C) IA(350) 4(100) I (25) BARREL I LEAKAGE OF AIR INTO THE PROTECTED LENGTH I AREA AND CONSEOUENT FORMATION OF -20'F (-29'C) 14(350) 6(INS) 3(75) -A- CONDENSATE AROUND THE FRAME. WHICH -30T (-34'C) 16(400) 8(200) 4(100) DIMENSION CLEARANCE COULD INHIBIT OPERATION OR CAUSE HOLE PREMATURE OPERATION SEE BELOW FOR -HOT (-40'C) 18(450) 8(200) 4(100) RECOMMENDED METHODS. -SOF(-46'C) 20(500) 10(250) 6 (150) _ -RUE(-5rc) 25(500) To(250) 6 (ISO) L NEEEEEEEEE • FOR AMBIENT TEMPERATURES EXPOSED TO THE DISCHARGE EEEEEEEBEE INSIDE SURFACE OF END OF THE SPRINKLER THAT OCCUR BETWEEN THE VALUES INSULATION, WALL, OR LISTED, USE THE NEST COOLER TEMPERATURE. ElEIEIEEMEE 1 �' CEILING THE MINIMUM EXPOSED BARREL LENGTH IS NOT THE SAME MIMI 1 AS THE A"DIMENSION. THE v VIMUM EXPOSED BARREL _= LENGTH IS BASED ON A PROPERLY SEALED PENETRATION WITH A MAXIMUM WIND VELOCITY ON THE EXPOSED SPRINKLER OF � 30 MPH (48 KM/H) LONGER EXPOSED BARREL LENGTHS WILL THERMAL J -- ESCUTCHEON HELP AVOID FREEZING OF THE WET PIPING WHERE HIGHER BARRIER WIRNND VELOCITY IS EXPECTED. •" THE MINIMUM EXPOSED BARREL LENGTH 15 MEASURED kliN -- -DISCHARGE END OF SPRINKLER FROM THE FACE OF THE FITTING TO THE INSIDE FACE OF THE INSULATION, WALL, OR CEILING LEADING TO THE COLC SPACE. PROTECTED(NON-CONDITIONED) AREA) WHICHEVER IS CLOSEST TO THE FITTING. • RECOMMENDED DRY SPRINKLER SEAL ARRANGEMENTS WET PIPE (DRY SPRINKLER WITH STANDARD ESCUTCHEON SHOWN) � WE-PIPE --T Fi ♦ J l -Wl- ' -F �F__ 0, 1 �1)ill--1- k - Illi , )UI--<- ] - - I -- L!-i— r-til L1-1.— _ri-tiJ 11 _ S — 5 r = •� U" (HEATED AREA) (HEATED AREA) MINIMUM MINIMUM EXPOSED I EXPOSED ENGTL E r SEAL BARREL LENGTH LENGTH OE FLASHING J INSIDE FACE (SEE ASOVE) RASCO(REC #4003910ENDED) (SEE ABOVE) (RECOMMENDED) 4/ r = I =r i— 'AIIIIIIMMINIAMINIS ' CLEARANCE HOLE INSULATED FREEZER, 4. OR COOLER STRUCTURE OR EXTERIOR FRAMING moi V hen (PROTECTED AREA) I 0 I1 DISCHARGE END OF (PROTECTED AREA) I - DISCHARGE END OF DRY SPRINKLER DRY SPRINKLER IN COLD AREA p N COLD AREA C OMORFEETI • Fig. 11 14. • *CAUTION* RELIABLE DRY SPRINKLERS MAY BE INSTALLED IN A LISTED CPVC SPRINKLER FITTING,ONLY UPON VERIFICATION THAT THE FITTING DOES NOT INTERFERE WITH THE SPRINKLER'S INLET. Do not install dry sprinklers with standard inlets into CPVC fittings that have an internal obstruction;this will damage the sprinkler,the fitting,or both. Short inlet("PL")versions of Reliable dry sprinklers are available that may or may not be compatible with fittings having internal obstructions in existing installations. Sprinklers with the short inlet("PL")should only be installed in CPVC fittings of wet-pipe systems. In all cases,verify sprinkler and fitting dimensions prior to installation to avoid interference. Internal No Internal T Obstruction Obstruction I % Female Female Pipe Pipe Thread— Thread CPVC Fitting with Internal Obstruction CPVC fitting - No Internal Obstruction • Shorter __= Longer Inlet �— Inlet Male Male Pipe �„ Pipe Thread / Thread ---'/ Dry Sprinkler Dry Sprinkler Short Inlet ("PL") Standard Inlet BE SURE TO ORDER THE CORRECT SPRINKLERS FOR YOUR APPLICATION COMDRYDEr2 • Fig. 12 15. .. e.y . . . 4 Fig. 13-Model 9Rwand y \ : . . » m.. . A � . . » 411«. . aƒ \ 4 Fig. 14-Model x o Wrench • 16. • MATERIAL SPECIFICATIONS 1� ITEM# DESCRIPTION MATERIAL SPECIFICATION • a` � 1 FRAME BRASS PER UNS C83600 ram. �_' 2 DEFLECTOR BRONZE PER UNS C51000 �`�r� 3 LOAD SCREW BRASS PER UNS C22000 s 4 SEAT ADAPTOR BRASS ALLOY PER UNS C36000 aD � t 5 BULB INSERT COPPER ALLOY PER UNS C31400 It 0 JVA$ 6 GLASS BULB GLASS W/GLYCERIN SOLUTION 7 ORIFICE ADAPTOR BRASS ALLOY PER UNS C36000 8 OUTER TUBE GALVANIZED STEEL 'JL 9 INNER TUBE BRASSALLOYPERUNSC23000 10 YOKE BRASS ALLOY PER UNS C38000 11 INLET BRASS ALLOY PER UNS C35330 12 CAP BRASS ALLOY PER UNS C54400 13 SPRING WASHER/SEAL PTFE COATED BERYLLIUM NICKEL 0 14 FLIP DISK BRASS ALLOY PER UNS C54400 • PAINTED OR PLATED MILD STEEL,EXCEPT CAN/ESCUTCHEON TYPE 316 STAINLESS STEEL FOR 15 SPRINKLERS WITH ENT FINISH 0 0 (PIPE WRENCH MAY ONLY BE USED ON OUTER STEEL PIPE OF SPRINKLER) • I,L _ AIi O II1 � COMDRYDETI3 o I1�f wi O 1%, I0 R: APPEARANCE OF DEFLECTOR MAY VARY DEPENDING ON MODEL Fig. 15 • 17. Installation Instructions Model F3QR56 Dry sprinklers must only be installed in the other than the wrench boss.When inserting or remov- following fittings: ing the wrench from the sprinkler, care should be tak- 1. The side outlet of an ANSI B 16.3 class 150(malleable en to prevent damage to the sprinkler. The sprinkler or ductile) or ANSI B16.4 class 125 (cast) iron pipe is then tightened into the pipe fitting to achieve a lea tee free connection.The recommended minimum to max- 2. The run outlet of an ANSI B 16.3 class 150 (malleable imum installation torque is 22 - 30 lb-ft (30-40 N-m) or ductile) or ANSI B16.4 class 125 (cast) iron pipe for 1" NPT and ISO7-1R1 sprinklers, and 14 - 20 lb-ft tee, with the side outlet plugged (wet-pipe systems (19-27 N-m)for 3/4" NPT and ISO7-1 R3/4 sprinklers. only) 3a.Alternatively, where access to the outer tube of 3. Spears Manufacturing Company Brass Thread In- the sprinkler is available, the Model F3QR56 Dry sert Style or Special Reinforced Plastic Thread Style sprinkler may be installed using a pipe wrench. Listed adapter or tee(wet-pipe systems only) (gasket The pipe wrench shall only be permitted to inter- sealed outlets shall not be used) face with the galvanized steel outer tube portion of 4. Any Listed CPVC sprinkler adapter or tee only in ac- the sprinkler (Item #8 in Fig. 15). Do NOT wrench cordance with Fig. 12 and upon verification that the any other portion of the sprinkler assembly. A pipe CPVC adapter or tee does not interfere with the sprin- wrench can install the sprinkler into the fitting with kler's inlet (wet-pipe systems only) (gasket sealed a large amount of torque; consideration should be outlets shall not be used) given to the need for future removal of the sprin- Model F3QR56 dry sprinklers must not be installed into el- kler because the installation torque will have to be bows, welded outlets, gasket sealed outlets, or couplings. matched or exceeded to remove the sprinkler.The Installation of the Model F3QR56 Dry sprinkler is not recom- recommended minimum to maximum installation mend in copper pipe systems, as this may reduce the life torque is 22 - 30 lb-ft (30 - 40 N-m) for 1" NPT expectancy of the sprinkler. and ISO7-1 R1 sprinklers, and 14-20 lb-ft(19-27 In all dry-pipe system installations,the Model F3OR56 Dry N-m)for 3/4" NPT and IS07-1 R3/4 sprinklers. sprinkler must be installed with protrusion into the fitting in 4. Standard and Model HB escutcheons can be in- accordance with Fig. 1 through Fig. 10 in this Bulletin. Do stalled by slipping the escutcheon over the can until not install Model F3QR56 Dry sprinklers with the standard the escutcheon is seated against the ceiling or wall. (long) inlet fitting into CPVC fittings that have an internal Model F1 escutcheons are installed by pressing the obstruction (see Fig. 12);this will damage the sprinkler, the escutcheon onto the collar until the escutcheon i fitting, or both. Model F3QR56 Dry sprinklers are available seated against the ceiling or wall. The Model FP es- with a short "PL" inlet fitting for installation on CPVC fittings cutcheon is installed by pressing or threading the es- of wet-pipe sprinkler systems only. cutcheon into the cup by hand; the escutcheon can Model F3QR56 Dry sprinklers connected to wet-pipe sys- be tightened against the ceiling or wall by turning the tems must be installed with the Exposed Minimum Barrel escutcheon in a clockwise direction and removed by Length required by Fig. 11 located in a Heated Area. turning the escutcheon in a counter-clockwise direc- An orange protective clip is factory installed on the sprin- tion.To install the Model CCP cover plate,first remove kler to protect the glass bulb thermal element from dam- the protective clip. Install the Model CCP cover plate age. The clip should remain in place during installation of on the sprinkler by pressing or threading the cover the sprinkler and be removed when the sprinkler system is plate into the cup by hand; the cover plate can be placed in service. Sprinklers with 3/4" NPT and ISO7-1R3/4 tightened against the ceiling by turning the cover inlets are supplied with a protective cap on the inlet that plate in a clockwise direction and removed by turning must be removed before installation. the cover plate in a counter-clockwise direction. Use the following steps for installation: 5. Remove the orange protective clip when placing the 1. Cut a hole in the wall or ceiling directly in-line with sprinkler system in service. the outlet of the fitting. See the Installation Data table for the recommended hole diameter based on the es- cutcheon or cover plate option selected. 2. Apply pipe joint compound or PTFE tape to the male threads of the sprinkler's inlet fitting. 3. Install the sprinkler in the fitting using the installation wrench specified in the Installation Data table. The Model F3R wrench is designed to be inserted into the groves in the sprinkler's wrench boss as shown in Fig. 13.The Model XLO2 wrench is designed to fit into the 11,cup and engage the wrench boss as shown in Fig. 14. Do NOT wrench any part of the sprinkler assembly 18. Installation Data Required Centerline of Sprinkler Sprinkler Suggested Hole Diameter Installation Tube/Inlet to Finished Ceiling Model Escutcheon or Cover Plate in Wall or Ceiling Wrench Vertical Dimension*. Standard Escutcheon 2-1/8"(54 mm) F3R HB Extondod Ecoutohoon 2 1/2"(61 mm) F3R F3QR56 Dry r1 n,.,es.od Eoeut..Lavn 2 1/4"(37,,,,,,) XLO2 Not Pendent Applicable FP Rco,,aocd Cacutchoon XLO2 9-119"(Re.rnrn) ccr CeA„ rlaL XL02 Standard Escutcheon 2-1/8"(54 mm) F3R 4-5/8"to 12-5/8" FHB Exrelded Escutcheon Z-12 (64 mml fail (118 mm to 321 mm) F3QR56 Dry 11 RuliuJSelt E uululTcvl l 2-1/4"(;,7 ) XLO2 cULus,NYC Horizontal 4-5/8"to 6-5/8" Sidewall rr fl,.eesscd Coeat„i,ee,, 2-1/2"(64,m„) XLO2 (118 mm to 168 mm) 11 ne,,e;s,,d CscutU on 2 1/4"(57,.„) XL02 FM 4-FP Ret,essed EeLut�lieun 2-1/2"(04 mid) XL02 /8"t 1 1 M (118 18 mm t m to 32 mm) F3QR56 Dry N/A 1-1/2"(38mm) F3R Not Applicable Upright *Note:Based on 5/8" (16 mm)centerline of sprinkler tube/inlet to defector vertical distance. Maintenance The Model F3QR56 Dry Sprinklers should be inspected 3. Inlet Threads: [1" NPT][IS07-1R1][3/4" NPT][IS07- and the sprinkler system maintained in accordance with 1R3/4] NFPA 25. Do not remove the factory applied thermally sen- 4. Inlet Fitting: [Long-Standard Inlet Fitting][Short "PL" sitive wax fillet between the bulb supporting cup and the -Wet Pipe Systems only] wrenching boss. Do not replace this wax with a substitute 5. Sprinkler Temperature Rating: See Temperature Rat- substance. ings table • An Alternate substance may interfere with proper operation 6. Sprinkler Finish: See Finishes Table of the sprinkler. Do not clean sprinklers with soap and water, 7. Escutcheon/Cover Plate Finish: See Finishes Table ammonia or any other cleaning fluids. Remove dust by us- 8. Length: ing a soft brush or gently vacuuming. Replace any sprin- *For dry pendents and dry sidewalls: "A" Dimen- kler which has been painted (other than factory applied) or sion is from face of tee to face of finished ceiling or damaged in any way. A stock of spare sprinklers should be wall in 1/4" (6mm) increments. See Fig. 1 through maintained to allow quick replacement of damaged or op- Fig. 9. erated sprinklers. Prior to installation, sprinklers should be *For dry uprights: Order dimension is from face of maintained in the original cartons and packaging until used tee to top of deflector in 1/4" (6mm) increments. to minimize the potential for damage to sprinklers that would See Fig. 10. cause improper operation or non-operation. Notes: Ordering Information 1. For Dry Upright,customer is responsible for determining Specify: the correct deflector distance from structure above. 1. Sprinkler: [Model F3QR56 Dry Pendent SIN R5714] 2. Length is based on normally gauged pipe thread"make- [Model F3QR56 Dry Horizontal Sidewall SIN R5734] up"of .600"(15mm) per ANSI B2.1 (approximately 7-1/2 [Model F2QR Dry Upright SIN R5724] threads). 2. Escutcheon/Cover Plate: [None][Standard escutch- eon][Model HB extended escutcheon][Model F1 re- cessed escutcheon][Model FP recessed escutcheon] [Model CCP cover plate-pendent only] The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Manufactured by • Reliable Automatic Sprinkler Co.,Inc. N♦ Recycled (80 ) 88 Sales Offices 'I Ir Paper Reliable (8000)4 848-60 3 1-1558-2042 Sales Fax Revision lines indicate updated or new data. (914)829 Corporate Offices www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.04/20 P/N 9999970175 Bulletin 204 Rev.Z December 2017 Reliable • Escutcheons Y+axnx.aea+^; :. Fire Sprinkler Escutcheons ;, Escutcheons enhance the appearance of fire sprinklers by cover- ing exposed fittings that are visible beyond finished ceilings and walls. Furnished to accommodate male pipe threads,the escutch- eon is held firmly in place by the sprinkler. The finishes provided are for decorative purposes and may weather or discolor when ex- posed to outdoor or corrosive conditions. Model B-One Piece Model B - One Piece Model B escutcheons are made of mild steel and are available in the finishes listed in Table A. Also available in stainless steel. • Diameter 2-7/e"(73mm);Depth: 11/6"(17mm) • Sprinkler Thread Size:lh"and 3/4" Model C - One Piece • Model C escutcheons are made of mild steel and are available in the finishes listed in Table A. • Diameter:2-'/8'(73mm);Depth:1/e"(3mm) Model C-One Piece • Sprinkler Thread Size: 1/2" Model HB -Two Piece -y;ri=�•1z � Model HB escutcheons are made of mild steel and are available in the finishes listed in Table A. Telescoping design permits up to 1"(25mm)vertical adjustment for variations in the distance that sprinklers extend below the ceiling. � r • Diameter: 3-1/2" (89mm); Depth: 2" min. (51mm), 3" max. (76mm) • 14 • Sprinkler Thread Size:1/2"or 3/4" Model HB-Two Piece Model F1 or F2-Two piece Model F1 and F2 escutcheons are made of mild steel and are avail- able in the finishes listed in Table A. Also available in stainless 4ee; steel. Model F1 permits up to 314" (19mm) vertical adjustment and Model F2 permits up to 1/2" (12mm)vertical adjustment. • Diameter. 2-7/" (73mm); Depth: F1 1'/e" (29mm), F2 7/e" (22mm) • Sprinkler Thread Size:1/"or 3/4" • Model F1 or F2-Two Piece www.reliablesprinkler.com Model F1S or F2S-Two piece Model F1S and F2S escutcheons are made of mild steel and are available in the finishes listed in Table A. Model F1S permits up • to 3A"(19mm)vertical adjustment and Model F2S permits up to —„ 1/2 (12mm) vertical adjustment. Oversized outer ring covers larger holes in ceiling that may be required for seismic pur poses. Note: All Reliable fire sprinklers listed with Model F1 or t F2 escutcheons may utilize the Model F1S or F2S escutcheon (respectively). • Diameter: 5" (127mm); Depth: F1S 1 1/3" (29mm), F2S '/3" Model F1S or F2S-Two Piece (22mm) • Sprinkler Thread Size:'/2"or 9/4" Model FV -Two Piece Model FV escutcheons are made of mild steel and are available in the finishes listed in Table A. Model FV has 'h" vertical ad- : • ^� justment. Designed specifically for use with the Reliable LT56 .�<• and LT56L sprinklers. Note: All NPT Reliable fire sprinklers that are cULus Listed with Model F2 escutcheons may use the r, Model FV escutcheon • Diameter: 2-'/"(73mm); Depth:'h"(22mm) • Sprinkler Thread Size:1/2" Model FV-Two Piece Caution: The Model FV escutcheon is not intended for use where the space above the ceiling is positively pressurized with respect to the occupied space below Model FP -Two piece �" \ Model FP escutcheons are made of mild steel with a galvanized • cup. Also available in stainless steel. The escutcheon ring is j available in the finishes listed in Table A. Push-on/thread-off feature permits up to 3/4"(19mm)vertical adjustment. • Diameter: 3-1/4" (83mm); Depth: 15/8" (24mm) • Sprinkler Thread Size: 1/2"or 3/4" Model FP-Two Piece Caution: The Model FP escutcheon is not intended for use where the space above the ceiling is positively pressurized with respect to the occupied space below. Escutcheon Finishes Table A Approvals Standard Finishes Special Application Finishes There are no listings or approvals required for non-recessed es- cutcheons such as the Model B and C one piece or the Model White Polyester Bright Brass Plated HB two piece escutcheon. These may be used with any exposed Chrome Plated Dull Chrome Plated fire sprinkler installation made in accordance with NFPA 13 require- Brass Plated Black Plated ments. Escutcheons used with recessed sprinklers must be part Black Polyester of a listed sprinkler assembly. Refer to the appropriate technical Custom Color Polyester bulletin of each sprinkler for this information. Note:The Model FP escutcheon assembly consists of an unfinished galvanized cup with a finished escutcheon ring. Ordering Information Maintenance Specify the following when ordering: Escutcheons for listed recessed sprinklers must remain in place, Model and shall be replaced if found missing. Non-listed metallic trim Thread Size rings for exposed sprinklers are often required for fire separation Finish purposes and should be replaced if found missing. 4101 8 Bulletin 204 Rev.Z ��'i�•_•� Page 2 of 2 December 2017 www.reliablesprinkler.com Bulletin 278 December 2017 Reliable • Model A Spare Sprinkler Cabinets Features: • Red enamel finish • Constructed of lightweight steel • Mounting holes provided • Five models available Product Description Reliable Model A Spare Sprinkler Cabinets are designed to meet the requirements of NFPA 13 and NFPA 13R that state: "A supply of at least six spare sprinklers shall be maintained on the premises 1 so that any sprinklers that have operated or been damaged in any way can be promptly replaced."These lightweight steel,red enam- el finished cabinets are quickly mounted using the holes provided. Model A3(12 Capacity) Model A4(3 Capacity) Table 1 Max.Sprinkler Size of Cabinet Model Capacity Thread Size inches(mm) (inches) Width Depth Height • A3 12 1 16-3/4 4 14-1/4 (425) (101) (361) A4 3 3/4 7-3/8 2-3/8 5-1/4 (187) (60) (133) A4 6 3/4 14-1/4 2-3/8 5-1/4 Model A4 (361) (60) (133) (6 Capacity) A4 6 1 14-1/4 6-1/2 3-1/8 Large (361) (165) (79) A4 12 3/4 14-1/4 4 5-1/4 (361) (101) (133) Location/Installation Location must be coordinated with, and installation made in ac- cordance with,the requirements of NFPA 13 or NFPA 13R, and all authorities having jurisdiction. Model A4 Large (6 Capacity) Guarantee For Reliable Automatic Sprinkler, Co., Inc. guarantee, terms, and conditions,visit www.reliablesprinkler.com. Ordering Information I • Specify: Cabinet Model Capacity(A4 Models) Model A4(12 Capacity) CO O Ut www.reliablesprinkler.com Bulletin 205 Rev. AF Installation co aT 1 • Reliable and Service Wrenches Sprinkler Wrenches: Model XLO EC AL Model G4 For Model: • G4 XLO QREC/EC For Models: • G4, G4FR, G4QR, F4FR, F4FR-NF Concealed Sprinkler &F4/RES ConcealedIIIP • RFC 56 Concealed Model GFR2 Model F3 For Models: $ e.- For Models: • F3/F3QR DryPendent& • F1, F1/EC, F1FR, F1FR/EC& 2ry HSW F1/RES/F2 Recessed Pendent vnik• G/F2&GFR Recessed • DH56 Dry EC HSW • F1/RES/F2&G/F1/EC4 This wrench is similar to the Model D wrench except the Recessed Horizontal Sidewall vir wrench opening is keyed and larger. Painted red. • G/F1 &F1 FR/EC8&9 • G/F1 Recessed Pendent • F1&F1FR Intermediate Level Pendent - Model XL02 • Model FP Push-On Recessed • F3/F3QR Dry recessed Escutcheon for F1 and F1FR &concealed pendent, _. Horizontal Sidewall • • Model FP Push-On Recessed HSW&DH56 • Escutcheon for F1 and F1FR GFR VELO Pendent For sprinklers with bulb protectors, the clasp of the bulb Pendents ,, ' protector must be facing out of the wrench as shown. • DH-80 Recessed • DH56 Recessed, DH56 Concealed • F156 and F1FR56 Recessed Pendent • FIRES 76 Recessed&CCP Pendent Model ZX • KFR56 HSW Recessed F1/F2/FP&Concealed Horizontal Sidewall • All Models that used GFR1 wrench For sprinklers with bulb protectors,the clasp of the bulb protector must For Models: be facing out of the wrench as shown. • XL QR,XL INST QREC Model RC1 For Models: • • G Recessed Pendent �� Model FC r '; • G1 &F1/RES Concealed Flat Concealed • G Intermediate Level Pendent .- • F1FR&F1FR QREC Concealed .' 6 For Model: y` F1FR56 & F1FR56 QREC • RFC30 • Concealed RFC 43 a, • KFR56 Pendent Recessed F1/ • RFC 49 Ili F2/FP&Concealed CCP • G5 A 1 ' square drive allows all the proceeding wrenches to be Model ZX Pendent i driven by the extension and ratchet used with the Model FC For Models: Sprinkler Wrench. These wrenches must be used with the • • XL QR, XL INST QR EC sprinklers indicated to minimize the possibility of damaging lit the sprinkler.The cavity of these wrenches provides sufficient support to the sprinkler to assure a safe, positive installation. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model D Model J1 For Models: For Models: • F1, F1 FR, F156, F1 FR56, • JL-14(ESFR) F1 RES, KFR56, G &GFR • JL-17(ESFR) • Pendent, Upright& HSW � - • J168 Upright • F1,F1 FR,F156,F1 FR56&G VSW • J112 ECOH Pendent&Upright • KFR-cCS,Upright • JL112 ECOH Pendent&Upright The "just right" length of these wrenches provides the leverage when tightening sprinklers into pipe fit- tings—preventing proper 9 9 9 P pP tings—preventing sprinkler damage. The slotted open- Model RJ ing prevents wrench slippage which could damage the For Models: sprinkler. Painted grey. • J112 Recessed Pendent Model H • JL112 Recessed Pendent III For Models: • GL112 Upright Model H1 • G XLO Upright • G &GFR VELO Pendent For Models : . , (ESFR) • GFR VELO ECOH Upright • ( ) Similar to Model D, except for wrench opening. Painted blue. Model N For Model: , • N252 EC Pendent ,,f t • N25(ESFR) This wrench is used for both recessed - and non-recessed sprinklers. Valve Wrenches: Model E Alarm Valve Seat Model A & D Dry Pipe Valve Seat Model B & BX • Model Cl & C2 Lever Bracket Nut Deluge Valve Seat Made of cast iron. These wrenches are specially designed to Model LDX Dry Pipe Valve :=r be used with Reliable Models A,C1,C2 and D Dry Pipe Valves. When used with C series valves,the lugs on the wrench engage Seat the slots of the Lever Bracket Nut. Removal of this nut permits Made of cast iron. Specially designed for il' lifting out the entire clapper assembly.When used with Reliable easily removing and replacing the valve Models A and D Dry Pipe Valves, the lugs engage ribs in the seat without damaging it. Has spaced slots N bronze seat and enable it to be unscrewed. for engaging seat lugs and a 1"or 11/2"hex The 11/2"hex boss on the top of the wrench allows it to be used boss for gripping with a standard open end, Typical with a standard open end,socket or adjustable wrench.Avail- socket or adjustable wrench. Valve Seat able in 4"and 6" sizes.The 4" size also fits the Model A 21/2" Dry Pipe Valve. Sizes Fit Models E Alarm Valves, B & BX Deluge & LDX Dry Pipe Valves Wrench Model Models Hex r Size E B, BX&LDX Boss " 21/s" 6881230000 -- 1" - 3" 6881230000 -- 1" 11V4tet v.4 4" 6881240000 6881240000 1Yx" . r� 6" 6881260000 6881506000 11/" ._._" '' -8" 6881280000 1 Yz" The equipment presented in this bulletin is to be instated in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years,and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries. • Manufactured by The Reliable Automatic Sprinkler Co.,Inc. Recycled 800)431-1588 Sales Offices Paper Rehaiiid ((800)848-6051 Sales Fax (914)829-2042 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG.Printed in U.S.A. 01/14 P/N 9999970036 Bulletin 208 Rev. M ® Sprinkler Guards co 5 Reliable : :: g 00 Model C Sprinkler Guards Model C Series sprinkler guards are designed to be assembled onto installed sprinklers. They are construct- ed of heavy gauge wire welded to steel mounting plates and finished with zinc plating.Other finishes are available. Guards protect automatic sprinklers in locations where w they are subject to physical damage. Refer to guard se- . I lection table for listing and approval information regarding specific sprinkler and guard combinations. All Model C guards are certified by FM Approvals. Models C-2 and C-3 also have cULus Listings. a • Model C-1 1 Model C-1 guards are used with pendent, upright, horizontal sidewall and vertical sidewall sprinklers. • Model C-2 Model D1 Sprinkler Guard Model C-2 guards are used with pendent dry sprin- klers. The sprinkler guard assembly is for upright interme- • Model C-3 diate level sprinkler applications. Model C-3 guards have a water shield attached.When • Model D-4 and D-5 • assembled to an upright sprinkler, the combination is Model D-4 and D-5 guards are D-1 guards supplied for upright intermediate sprinkler applications. with an original water shield which is threaded on • Model C-5 ('/2") or passed over (3/4") the sprinkler inlet thread. The combination forms a pendent intermediate level Model C-5 guards are supplied with a water shield sprinkler. and 0-Ring which are assembled to the sprinkler be- fore the sprinkler is installed. The guard is then in- • Model D-8 stalled to the sprinkler after it is installed in the fitting. Model D-8 guard can be assembled to pendent Model D Sprinkler Guards sprinkler. The Model D Series sprinkler guards are supplied as • Model D-9 kits to be assembled to the sprinkler at the job site before The Model D-9 guard is a model D-8 guard supplied sprinkler installation. The kit consists of the guard, '/z" and with a water shield that is passed over the 3/4"sprinkler 3/4" locknuts and a water shield when being used as an inlet thread. The combination forms a pendent inter- intermediate level sprinkler.The pendent intermediate has mediate level sprinkler. an 0-Ring supplied. The Model D9 does not require an Guards and water shields are finished with zinc plat- 0-Ring. ing. Other finishes are available upon request. Each guard type is fabricated of heavy gauge wire Refer to guard selection table for listing and approval welded to steel mounting plates and complies with the lat- information regarding specific sprinkler and guard com- est UL standards. Guards protect automatic sprinklers in binations. locations where physical damage can occur. patents: Model D Series guards are also available factory as- sembled on the sprinkler ready for immediate sprinkler/ USA Patent Number 5,893,418 guard installation. Consult factory for availability. Applies to Model D Series Guards • Model D-1 Listings & Approvals Model D-1 guards can be assembled to pendent, up- 1. Listed by Underwriters Laboratories, Inc. and • right and horizontal sidewall sprinklers. UL certified for Canada(cULus) 2. Certified by FM Approvals • Model D-3, D6 and D-7 3. NYC MEA 258-93-E Model D-3, D6 and D-7 guards have a water shield 4. Scientific Services Laboratories (SSL, Australia)* attached and are assembled to upright sprinklers. * For Models Cl, C2, C3 guards. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model C-1 Guards -� m�� � � �-tom >;; � I. Iii I I�� 11 Il I I2 gg"[73mm] + ,' „ b -_ +, t 2 y'" [7omm] SHOWN MODFI G UPRIGHT SPRINKLER SHOWN MODEL G PENDENT SPRINKLER + 208C IC Model C-2 Guards 3 I 2 3 Bomm) SHOWN MODEL F3 PENDENT SPRINKLER 20242 Model C-3 Guards • 4 -[I 14mm] t --pi" 2 3"(70mm) —� ,4 ' t `1 I^ P lr �Y� ; 1 I , , 1 11 SHOWN MODEL El ER UPRIGHT SPRINKLER SHOWN MODEL G UPRIGHT SPRINKLER SHOWN MODEL GER UPRIGHT SPRINKLER f ~ 20803C Model C-5 Guards J a"[82mm] L 6l&_4W d t � i , , ,ai4 ,, , ,. _ 3"[76mm] �_ i N, '7.,7 ./ I SHOWN MODEL F1 FR PENDENT SPRINKLER SHOWN MODEL Fl PENDENT SPRINKLER • SHOWN MODEL G PENDENT SPRINKLER `¢* - 208CSC _.... 2. Model D-1 Guards Model D-3 Guards 2"[76mm] 4 1j"[I14mm] a rre'n a _ I1257m3 ,, rT-Y'l Y' _it SHOWN MODEL G SPRINKLER SHOWN MODEL F1 SPRINKLER UPRCM affair  `- - SHOWN MODEL G SPRINKLER SHOWN MODEL El SPRINKLER UPRIGHT UPRIGHT r Model D-5 Guards Esc _7. ---- _ Ir 71 _ _ I�T�I__ "� r '� Eail _ 111 SHOWN MODEL G SPRINKI FR CHOWN MODEL E1 SPRINKLER •-_ PENOFM PiNO(RT Ali -- - IIII �■■u .�.. l ` "I if' ,II II1I� SHOWN MODEL 61/2' NPT SPRINKLER SHOWN MODEL El 1/2" NPT SPRINKLER ��,-I rI!t1 11 EVIDENT IMERMEPtATF PENOPIAT IMFRMFOWTF J Willi -3{"[82mm] CHOWN MODFI G SPRINKLER SHOWN MODEL Fr SPRINKLER .OM]nsrAI SIRIVAll XI601C RORIIFONTAL swim, Timm• _ L1 _71 -... 17� _ Model D-7 Guards 101 ILi 1111 4i[114mm] I 1 � . !i' I d r53mm] 1111 L. r SHOWN MODEL G 3/4" HINT SPRINKLER SHOWN MODEL El 3/4" NPT SPRINKLER / I PENDENT IMFRMENATF PERCENT rMfRefFMATF 109050 D7 Model D-6 Guards SHOWN MODEL CL 112 OR 4}"[114mm] UPRILHT S 2,N=,no __ _ i.... Model D-4 Guards I� 4?' II lamm] y - fR z;"C�om] } T nil" _ I -- _-tell - --U'l _ «'' l -ittiiiii .3 r[67m rNI _ .\- I�_.I - Ill s MODEL G XLD231 1/2" NPT SPRINKLER MODEL G XL0231 3/4" NPT SPRINKLER UPRICM IMFRMFOIATE UPRIGHT INTERMEDIATE NaMI(O4JrA SHOWN MODEL DR 1/2" NPT SPRINKLER SHOWN MODEL GFR 3/1" NPT SPRINKLER Model D-9 Guard PERM.;INFERMFOLIIF PERCENT INTFRMF1HTf 208040 3 1/4"[83.3] Model D-8 GuardIR fiiill 1.i 1.1 ,..„ 1 .1 1/z'(24.AJ z rn"rR�3/ �'� 111111 'I1 .1 zcem 3-nfl)1 za3ar SHOWN MODEL GL112 PENDENT 3/4" NPT SPRINKLER SHOWN MODEL GL112 PENDENT 3/4" NPT SPRINKLER PFNDDUT auTERMEaArt PN#RS SPRLAwIFR 3. Guards are approved to be used with sprinklers listed below. Approvals with SIN Number Guard Model l3 Sprinkler Model Sprinkler Type Orifice Sizes MEAD'),SSLJ2l Application • cULus FM R3611, R3613, R3615,R3612, R3621, R3623, R3625,R3622, R3111, R3113, R3115,R3117, R3121, R3123, R3125, R3127, R3635,R3131,R3133, R3135, R3137,R1711,R1713, R1715, R1712,R1721,R1723, R1725, G,GFR,F1,F1FR, R1722,R1735,R1011, R1013, D-1 F156,F1FR56, Pendent,Upright,HSW 3/8 ,7/16",'/z", R1015,R1016,R1017, R1021, RA1314,RA1414, KFR56,F1FR-300 17/32" R1023,R1025,R1026, R1027, RA3614 R1231,R1233,R1235, R1236, R1237,RA1314,RA1414, RA1325,RA1425,RA3614, R5612,R5622,RA3624, RA3634,RA1335,RA1435, RA1311, RA1321,RA1411, RA1421, RA1313,RA1323, RA1413, RA1423 R3625,R3622,R3125,R3127, G,GFR,F1,F1FR, R1725,R1722,R1025,R1026, D-3 F156,F1FR56, Upright Intermediate 1/2", 17/32" R1027, KFR56 RA1325, RA1425,RA3195, RA3125,RA3624 D-4 G,GFR,F1,F1FR, Pendent Intermediate %z" 17/32 R3115,R3117 RA1314,RA1414, KFR56 (Large Shield) RA3614 G, F1, F1FR,F156, R3615,R3612,R1715, R1712, D-5 F1FR56,KFR56, Pendent Intermediate %z" 17/32 R1015,R1016,R1017, RA1314,RA1414, F1FR-300 (Small Shield) RA1314, RA1414, RA3614, RA3614 • R5612 D-6 G XLO Upright Intermediate 0.64 R2921 D-7 GL112 Upright Intermediate 11.2 R3226 D-8 GL112 Pendent 11.2 R3216 D-9 GL112 Pendent Intermediate 11.2 R3216 R1011,R1015,R1016, R1017,R1021,R1025, R1026,R1027,R1235, R1285,R1712,R1715, G,F1,F1FR, Pendent,Upright, R1721,R1725,R1735, C-1 F156,F1FR56, HSW,Vertical Sidewall, 3/8",Y", 17/32" R R36 R3615, KFR56 Upright&Pendent R33622622,,R362255,,R3635, R3685,RA1314,RA1414, RA1325, RA1425, RA1335,RA1385, RA1435,RA1485, RA3614 C-2 F3,F3OR Pendent %" R1616,R5314,R5714,R4216 R5314,R5714 R3625,R3622,R3125,R3127, R3625,R1725, R1025, G,GFR,F1,F1FR C-3 F156,F1FR56, Upright Intermediate 1/2", 17/32" R1725,R1722,R1025,R1026, R1027,RA1325,RA1425, KFR56 R1027,RA1325, RA1425, R3622,RA3195,RA3125, RA3195, RA3125,RA3624 R3127 G,GFR,F1,F1FR R1015, R1017,R3615, R1715, R1712,R3612, C-5 F156,F1FR56, Pendent Intermediate 1/2", 17/32" KFR56 RA1314,RA1414, RA3614,R3117 MEA approval on D-1,D-3,D-4,D-5,C-2,and C-3 • (2)SSL approval on C-1,C-2,and C-3 (3)Sprinkler guards are listed and approved only for use with specific sprinklers. The use of any other guards on these sprinklers may impede their operation or distribution and negate all approvals and warranties. 4. Installation Instructions For D-1, D-3, D-4 or D-5, sprinklers SIN numbers R1017, R1027, R3117 and R3127 use Model J wrench. • Model C Guards All other sprinklers use JD wrench. • With both cups unhooked, slightly spread open the The D-7, D-8 or D-9 should be wrenched into place guard. Insert steel plate into the installed sprinkler be- using the JV guard wrench. tween the threads and the wrench flats. The steel plate tabs should face the sprinkler wrench flats and four con- Wrench must be placed over the guard. Do not use tact points engage the sprinkler neck. the wrench directly on the sprinkler wrench boss. The For Model C-2, the steel plate fits into the groove in sprinkler wrench boss requires a special wrench. each wrench flat and the guard is located by the notch in both steel plates. Snap the upper locking clip into place, then close the Finish near clip. The guard is now securely installed in place. Standard Finish—Zinc with chromate dip. If locking clip requires too much force to snap closed or Other finishes, quoted on request. open, slightly flex the wires on both sides of the clip and either close or open the clip. Ordering Information • Model D Guards • Guard Type (D-1, D-2 etc.) Model D-1 • Finish (Standard or other) Assemble the guard on the sprinklers using the follow- • Sprinkler Inlet Thread Size, ing technique. D-4& D-5 Guards Only. With both cups unhooked, slightly spread open the • Optional: Consult Factory for assembly on guard. Insert steel plate into the installed sprinkler be- sprinkler. tween the threads and the wrench flats. The steel plate Specify Sprinkler: tabs should face the sprinkler wrench flats and four con- -Type. tact points should engage the sprinkler neck. -Temperature Rating. Snap the upper locking clip (steel plates) into place. - Finish. Close the lower clip at the top of the guard and slide it • Wrench: J, JD or JV wrench. down to the notch.The guard is more securely installed. . Install the lock nut on to the NPT threads until the nut is securely against the guard. Model D-3, D-4, D-5, D-6, D-7, D-8 & D-9 Before a sprinkler is installed into a fitting, assemble the guard on the sprinkler using the same technique described for the Model C Guards. Then install a 'h" or 3/4" locking nut on to the NPT threads until the nut is tight against the guard. Each guard is supplied with both size of locking nuts. • 5. Reliable. . . For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many • precision-made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Deluge valves • Flush automatic sprinklers • Detector check valves • Recessed automatic sprinklers • Check valves • Concealed automatic sprinklers • Electrical system • Adjustable automatic sprinklers • Sprinkler emergency cabinets • Dry automatic sprinklers • Sprinkler wrenches • Intermediate level sprinklers • Sprinkler escutcheons and guards • Open sprinklers • Inspectors test connections • Spray nozzles • Sight drains • • Alarm valves • Ball drips and drum drips • Retarding chambers • Control valve seals • Dry pipe valves • Air maintenance devices • Accelerators for dry pipe valves • Air compressors • Mechanical sprinkler alarms • Pressure gauges • Electrical sprinkler alarm switches • Identification signs • Water flow detectors • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years,and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries. Manufactured by �'�j) • Reliable Automatic Sprinkler Co.,Inc. W Recycled (800)431-1588 Sales Offices Paper !Reliable (800)848-6051 C Fax (914)829-2042 Corporp Fax Offices Revision lines indicate updated or new data. 111 www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.03/15 P/N 9999970152 T S �,k F }y t14/ 0 4 i-ti(--, 2 . ,Sl,{'� �/,• Alt./ •4‘,,, - A.•,,,,..,,, p. s _... . ....... , ......, .,..: X 1'444" i .,, ce cc fix, V, `3n. W1111ill 4 ci: '27 \ / occ Q • 4.4,44444 , - . v � / cola �s R Ali ti / 3 qn € 41 ?ill!: y'' !am i //{ x 0,. ! f Q 11 .11 :. ••' . .1 . \ ,,, Apoi: ‘, memo • i.: Ky k . .. 6 r.. ':('''. .. , ! M ...... ..�«- r, r .., x ' sky '� -� ' V 1 s^j, «`^is. $a• .srS ' ?{ / .--.. r 4; .4:4 s 61 Me k x, _ m YCI '�} M aF' • 1.1 • i g '[ ' Y� `k > =' 9pCy���Y3 . 0 ° Yiiiii{! ,u r !� # r 5 W ..Yu xw: . .: . o . ., l s { oS1'3 1S ���(" � 73 A r i I tpsa i iIPti^..: .. o { sy ! ! !r Ewa . a fr. We invented the concept of.'ftxible fire protection TM tY' The FlexHead Advantage FLEXHEAD QUALITY FLEXHEAD FEATURES • Best corrosion resistance • Is seismically qualified for use, Made from 100% 304 stainless steel eliminating the need for an oversized '` ring around the sprinkler head in • Excellent friction loss values One inch true bore ID reducing the need to seismic areas upsize mains and branch lines • Has the same product design that is Pressure surge protection dual listed by both UL and FM • Fully braided connection improves pressure • Can be produced domestically to meet all your project requirements capability and prevents hose damageiii �..----•— • Highest maximum working pressure • Has serial identification with complete audit trackingof finished goods . Rated up to 300 psig • No o-rings or gaskets • Has a comprehensive limited warranty Welded connections reduce potential leak backed by an A++ insurance company points at the inlet and outlet fitting iiiiiiiiii • Tightest thread tolerances iiiiiiiiiiii Outlet fitting threads are machined from solid bar stock reducing potential leaks _ at the sprinkler head fit-up aI • Extra stability Bracket has a full 6 inch base to stabilize { ,i i* the sprinkler head during installation, ,'°{r ii " F1' ""ti•u: pressurization or activation a i ? [ xeras :-**.i i -----, ,,-,, �k k} r e < : �"+ems -• 4 G3 tl , ,,,:. ,,:.-...„,„4„.„„,,.,„„„,,,,:,„,,,,,,„,„,„,,„,„,„,„,,,,.„,„.„,„,,,, , I S F ei 4t ItlIP G t: tl i 4IY. dI n ..�k , .a. S tlA 9i ....... ...YYYuuu +�. y�yy'++3 .; ¢$'" F pqiP iIF IMt- 3 � '� A J[k9lt5 �@Y"[ p Fart C 9i�kiS T •.j,,,, ,,„,..,„ ,., w 0 kk d o P 6 kI eI .. 4 $!A¢AY 4 {I Yrri -i [ r v k, t S 5 { tl x� ,i 444444rtN:i :':;� pZ[ s i il�silY, e *s µt rels:Yliu :�: mte tl !1 I t4!g [ . ?x A YUasik kle[ 0¢!d� [rk ISI[I Y e :}t, wy, tCt '. TABLE OF CONTENTS Introduction 2 Table of Contents 3 Installation Instructions 4 - 5 NFPA 13 Code Language and Seismic Qualification 6 - 7 Friction Loss Data and Specifications 8 Suspended Ceiling Detail 9 Hose Specification Sheet 10 Bracket Specification Sheet 11 FlexHead Commercial Products 12 FlexHead Products 13 • FM Global:Testing &Approvals 14 - 15 UL: Testing and Listings 16 - 17 CA Office of Statewide Health Planning 18 - 19 and Development Other Approvals/Information 20 - 21 Earthquake Case Study& Limited Warranty 22 - 23 Whether your application is commercial, industrial, clean room, or institutional, FlexHead flexible sprinkler systems can save you time and money by offering reliable, highly efficient, seismically qualified, and environmentally responsible products. • FLEXHEAC � 800.829.6975 INDUSTRIES ...,o_s. atkore We invented the concept of flexible fire protectionTM INSTALLATION INSTRUCTIONS „ ^ .., • Fig.2 Tools Required Standard pipe wrench Safety glasses Adjustable wrench Drill Materials Required _ °m , ri Sprinkler pipe thread sealant Teflon®tape For use with FlexHead hose model numbers 20XX, A. Remove bracket system from box. From above the 20XXH, where XX designates hose length in inches, ceiling, position FlexHead Mounting Bracket ends on to with MPO-24-BKT-2 bracket system. T-bar grid so that the center hole in support bracket 0 Mounting Bracket Assembly: MPO-24-BKT-2 aligns directly above the sprinkler hole prepared in (Optional step if required to move open hub ceiling tile. Be sure the center section of the bracket center position) end is on the outside of grid and base section is on the inside. Position the ends of the support bracket on If required to move open hub center position on bracket, the T-bar grid and push each of the two(2)ends of the follow step 1 otherwise start at step 2 below. (Fig. 1) bracket down to snap in place as shown. (Fig. 2) A. Remove one(1)3/8" bolt and one (1) %a" bolt from Figs . • bracket. Remove(1) Open Hub and Select one (1)of the four(4)sprinkler port locations on mounting bracket. .. .?.S Thread the 3/8"bolt through side of open hub, (Fig. 1) B. Insert tab of open hub into slot on mounting bracket as shown. C. Flip bracket over and insert and tighten 1/a"attachment bolt thru pre-punched hole in bracket until tight as shown. Fig.1 0 Anchor Bracket to T bar Grid A. Anchor bracket to t-bar grid with self tapping screw through bottom hole in bracket end into grid. Be sure to install self tapping screw in lower hole of bracket end as shown. Repeat process on opposite end of bracket. Both ends of bracket should be anchored as shown. (Fig. 3) • �f 'n 0 Connect FlexHead to Sprinkler Branch-line A. Apply Teflon tape and pipe sealant to one inch (1") ()Attach Mounting Bracket to T bar threaded end of FlexHead Sprinkler Drop per NFPA Suspended Ceiling Grid guidelines. Attach one inch(1")threaded end of Note:These products are designed for use with Intermediate or FlexHead Sprinkler Drop to branch-line per NFPA, Heavy Duty ceiling grids manufactured to ASTM C 635(Standard State and local code guidelines. Specification for the Manufacture, Performance,and Testing of Metal Flexible Sprinkler Hose Fittings are only to be installed • Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings) with bends. Do not install without bends, and ASTM C 636(Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tle and Lay-in Panels)Designation. (See attached Friction Loss Data information for maximum number of bends per hose length.) 4 FLEXHEAU INDUSiR,E5' 0 www.flexhead.com «I.,a�kWe B. Tighten FlexHead Sprinkler Drop using pipe wrench to the drop head surface as shown. (Fig. 4) ' • Do not use welded or braided hose section of FlexHead ° e Sprinkler Drop for a wrenching surface. § _ •>. � A Fig.4' It S4o E *4 e ... ... _.t:E L��a lNe ✓4 F fry 0 Secure FlexHead Sprinkler Drop to Mounting .. Bracket and Install Sprinkler Head c t�_ 0 1 na, c. ay A. Bend the FlexHead to hold its desired position. Do not over bend the flexible hose. Each FlexHead sprinkler drop has a 3"(76mm) minimum bend radius per UL and 8" (203mm) minimum bend \ 4. radius per FM guidelines. (See attached Friction Loss Data information for maximum number of bends per • hose length.) Insert reducing coupling end of FlexHead Sprinkler Drop through center hole in previously installed • support bracket and hole in ceiling tile. Make sure the F'9'Sc hose is bent sufficiently so that the reducing coupling sits ` ' perfectly vertical in center hole of support bracket. Do ",' not torque or twist FlexHead during installation process. (Fig. 5a) "rift B. Close hub on bracket and turn the lock shaft 1/4 turn e : clockwise as show. Lock hub closed. (Fig. 5b) C. Adjust FlexHead Sprinkler drop height to accommodate , .. , ;, -r , type of sprinkler head to be used. When sprinkler head is - B,- in desired location,tighten the 3/8 set screw on center „„ hub of support bracket by turning clockwise hand tight plus 1 turn (torque 100 inch Ibs)with wrench as shown in (Fig. 5c). � � , ,� a. D. If sprinkler head is not pre-installed, attach sprinkler „, f �$S l head, properly prepared with Teflon tape and sealant to %. '° " FlexHead Sprinkler according to NFPA and sprinkler £> s �" head manufacturer's guidelines. (Fig.5d) -'+ F 0 Installation of the FlexHead Ceiling Sprinkler _.. , 'I � System Is Complete ` _ - III •Test installation of sprinkler system for any leaks per NFPA Guidelines. _..,.,. •, �:; ,.....:; , e�...: .......:. � , • Install sprinkler escutcheon from below ceiling per manufacturers guidelines. FLEXHEAID 800.829.6975 INDUSTRIES 7..:) 111 We invented the concept of flexible fire protection' NFPA 13 CODE LANGUAGE & SEISMIC QUALIFICATION , NFPA 13 STANDARD FOR INSTALLATION OF SPRINKLER SYSTEMS 2007 EDITION 9.2.1.3.3* Flexible Sprinkler Hose Fittings. 9.2.1.3.3.1 Listed flexible sprinkler hose fittings and its anchoring components, intended for use in installations connecting the sprinkler piping to sprinklers, shall be installed in accordance with the requirements of the listing including any installation instructions. 9.2.1.3.3.2 When installed and supported by suspended ceilings,the ceiling shall meet ASTM C 635, Standard Specification for the Manufacture, Performance, and Testing of Metal Suspension Systems for Acoustical Tile and Lay-In Panel Ceilings, and shall be installed in accordance with ASTM C 636, Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-In Panels. 9.2.1.3.3.3` When flexible sprinkler hose fittings exceed 6 ft(1.83 m) in length and are supported by a suspended ceiling in accordance with 9.2.1.3.3.2, a hanger(s)attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft. (1.83 m). 9.2.1.3.3.4` Where flexible sprinkler hose fittings are used to connect sprinklers to branch lines in suspended ceilings, a label limiting relocation of the sprinkler shall be provided on the anchoring component. A. 9.2.1.3.3.3 The committee evaluation of flexible sprinkler hose fittings supported by suspended ceilings was based on a comparison of the weight of a 6 ft, 1 in(1.8 m)diameter Schedule 40 water-filled unsupported armover weighing approximately 13 lb (5.9 kg)to the weight of a 6 ft, 1 in. (1.8 m)diameter water-filled flexible hose fitting weighing approximately 9 lb(4.1 kg).The information provided to the committee showed that the maximum load shed to the suspended ceiling by the flexible hose fitting was • approximately 6 lb(2.7 kg)and that a suspended ceiling meeting ASTM C 635, Standard Specification for the Manufacture, Performance, and Testing of Metal Suspension Systems of Acoustical Tile and Lay-In Panel Ceilings, and installed in accordance with ASTM C 636, Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-In Panels, can substantially support that load. In addition, the supporting material showed that the flexible hose connection can be attached to the suspended ceilings because it allow the necessary deflections under seismic conditions. Reproduced with permission from NFPA 13-2007, Standard for the Installation of Sprinkler Systems, Copyright© 2006, National Fire Protection Association. This reprinted material is not the complete and official position of the NFPA on the referenced subject, which is represented only by the standard in its entirety. • 6 FLEXHEAD1 INDUSTRIES-LO www.flexhead.com vnatkare FLEXHEAD° SATISFIES NEW SEISMIC CODE REQUIREMENTS Pipe nipple mt'1'1? #ftfttIHl1 Typically, each unit consists of a threaded ++H►1qq►11111►IN► NHNI ,tlPNlll'INN,H1►►►►1►►►1u►� -li r111NH►IIN.Nu, . 0 pipe nipple for connecting to the main or ,111111111 �� ,f1►111111►'�(t�t� branch feeder line, a flexible hose in 011111111' Sprinkler ',rs11011111ii' branchtine standard lengths, a reducing fitting that r$0111N i the sprinkler head attaches to, and a i11►11111j1111+0 I►l11lllr Flexible connecting hose in standard mounting bracket. 111►111 lengths—allows the head to move in ►1►1111111 any direction during a seismic event IIj1j1111I►1 without causing damage to the Mkt sprinkler system Mounting bracket ' Reducing fitting Em, ,I Suspended rr(II'11 t-bar grid Ceiling tile • Sprinkler head FlexHead Industries recently satisfactorily completed full-scale seismic qualification testing at the Structural Engineering Earthquake Simulation Laboratory located at the State University of New York at Buffalo. Tests were conducted using the International Code Council(ICC)acceptance criteria"ICC-ES AC-156 Seismic Qualification Testing of Nonstructural Components". This is the first time a sprinkler component has been seismically certified using test criteria accepted by the ICC. • More than 90% of the states in the U.S. are adopting the and other penetrations shall have a 2-inch oversized ring, International Building Code (IBC)that address, among sleeve, or adapter through the ceiling to allow for free other things, the installation of fire sprinkler systems in movement of at least 1 inch of ceiling movement in all seismic zones. horizontal directions. •The latest version of the IBC defers to ASCE 7 for the • Flexible sprinkler connection provide characteristics that sprinkler/ceiling design in Seismic Design Categories exceed the most stringent seismic code requirements. 9SDC) C and D, E &F. The flexibility of the hose allows the head to move with • In Seismic Design Category C, suspended ceilings are to the ceiling in any direction during a seismic event without be designed and installed in accordance with Ceilings& causing damage to the sprinkler system. Interior Systems Construction Association(CISCA) • FlexHead Industries recently satisfactorily completed recommendations for Zones 0-2; and sprinkler heads full-scale seismic qualification testing at the Structural and other penetrations shall have a minimum of 1/4-inch engineering Earthquake Simulation Laboratory located clearance on all sides. at the State University of New York at Buffalo using the • In Seismic Design Categories D, E &F, suspended International Code Council (ICC)testing standard "ICC ceilings are to be designed and installed in accordance AC 156 Seismic Qualification Testing of • with CISCA recommendations for seismic Zones 3 and 4 Nonstructural Components". with some additional requirements. Except where rigid braces are used to limit lateral deflections, sprinkler heads FLEXHEAD 800.829.6975 INDUSTRIES'1) We invented the concept of flexible fire protectionTM + d as sra.0 a a p zNr r rWx .,.: a �' �F+r �s a1a i= ;s k i. � 'e k mr :d i, p n A ink}+on s s z r rtn tl ai FRi T N � 'DATA£ PECI ar a" F i 'S 2Yjtlt iara�Ytl }� '.. .Ix 4t ' .y a p 41, ii Outlet Hose Maximum Number Maximum Equivalent ' Maximum Maximum Rated Internal . Orifice Assembly of Length of Schedule 40, Ambient Pressure FlexHead Maximum LD. Size Length 90-degree Bends Nominal 1in.Diameter Temperature psi(kPa)/psi(kPa) Model# K-factor 3"-UL ' 8" FM Pipe,ft Rating in • in(cm) ft(cm) 175psi 30bpsi 1, FM UL F(C) Standard H-Series 2024,2024H 1 1/2(1.27) 2(0.6) 3 1 2 18.4 11 300°(148°) 175(1205)/300(2068) 5.62 2036,2036H 1 1/2(1.27) 3(0.9) 3 2 3 26.6 16 300°(1489 175(1205)/300(2068) 5.62 2048,2048H 1 1/2(1.27) 4(1.2) 4 3 4 30.3 24 300°(1481 175(1205)/300(2068) 5.62 2060,2060H 1 1/2(1.27) 5(1.5) 4 4 4 35.8 29 300°(1481 175(1205)/300(2068) 5.62 2072,2072H 1 1/2(1.27) 6(1.8) 4 4 4 45.6 35 300°(148°) 175(1205)/300(2068) 5.62 2024 75,2024H 75 1 3/4(1.90) 2(0.6) 3 1 2 14.7 12 300°(148°) 175(1205)/300(2068) 14.0 2036 75,2036H 75 1 3/4(1.90) '' 3(0.9) 3 2 3 21.8 18 300°11489 175(1205)/300(2068) , 14.0 2048 75,2048H 75 1 3/4(1.90) 4)1.2) 4 3 4 29.0 23 300°(148°) 175(1205)/300(2068) 14.0 2060 75,2060H 75 1 3/4(1.90) 5(1.5) 4 4 4 36.1 29 300°(148°) 175(1205)/300(2068) j 14.0 2072 75,2072H 75 1 3/4(1.90) 6(1.8) 4 4 4 43.2 32 300°(1481 175(1205)/300(2068) 14.0 175psi,300psi 2024E,2024HE 1 1/2(1.27) 2(0.6) 3 1 2 26.4,14.7 19 300°(1481 175(1205)/300(2068) 5.62 2036E,2036HE 1 1/2(1.27) 3(0.9) 3 2 3 30.1,21.8 23 300°(1481 175(1205)/300(2068) 5.62 2048E,2046HE 1 1/2(1.27) 4(1.2) 4 3 4 33.8,29.0 27 300°(148°) 175(1205)/300(20681 5.62 • 2060E,2060HE 1 1/2(1.27) 5(1.5) 4 4 4 37.5,36.1 32 3000(148°) 175(1205)/300(2068) 5.62 2072E,2072HE 1 1/2(1.27) ' 6(1.8) 4 4 4 41.2,43.2 35 300°(148°) 175(1205)/300(2068) I 5.62 2024E 75,2024HE 75 1 3/4(1.90) 2(0.6) 3 1 1 14.7 18 300°(148°) 175(1205)/300(2068) 14.0 2036E 75,2036HE 75 1 3/4(1.90) 3(0.9) 3 2 ', 2 21.8 23 300°(148°) 175(1205(/300(2068) 14.0 2048E 75,2048HE 75 1 3/4(1.90) 411.2) 4 3 3 29.0 23 300°(148°) 175(1205)/300(2068) 14.0 2060E 75,2060HE 75 1 3/4(1.90) 5(1.5) 4 4 4 36.1 29 300°(1481 175(1205)/300(2068) 14.0 2072E 75,2072HE 75 1 3/4(1.90) 6)1.8) 4 4 4 43.2 32 300°(148°) 175(1205)/300(2068) 14.0 2036F 1.25 1/215.6) 3(0.9) 3 - 16.0 300°(148°) 175(1205)/300(2068) 5.62 2048F 1.25 1/2(5.6) 4(1.2) 4 - 19.6 300°(148°) 175(1205)/300(2068) 5.62 2072F 1.25 1/2(5.6) 6(1.81 4 22.8 300°(148°) 175(1205)/300(2068) 5.62 2036F75 1.25 3/4(14) 3(0.9) 3 - 9.3 300°(1481 175(1205) 14.0 2048F75 1.25 3/4(14) 4(1.2) 4 11.4 300°(1481 175(1205) 14.0 2072F75 1.25 3/4(14) 611.8) 4 - 15 300°(1489 175(1205) 14.0 2036F100 1.25 1 (141 3(0.9) 3 7.1 300°(148°) 175(1205) 22.4 2048F100 1.25 1(14) 4(1.2) 4 - 8.3 300°(148°) 175(1205) 22.4 2072F100 1.25 1 (14) 6(1.8) 4 - 10.1 300°(148°) 175(1205) 22.4 Model Numbers:The"H"designates high pressure unit rated to 300 psig and the"E"designates elbow style unit.The'F"designates high flow rate using 1 1/4°internal hose diameter. FlexHead products are intended for use in hydraulically designed wet,pre-action,deluge or dry pipe sprinkler connections per NFPA 13, 13R,and 13D guidelines.The hydraulic loss of III FlexHead connector needs to be included in the hydraulic design calculations the same as a valve or fitting.Each FlexHead sprinkler drop has a 3"minimum bend radius per UL guidelines,and a 8"minimum bend radius per FM guidelines. "FM Equivalent Length Numbers include maximum'K"factor sprinkler head that is listed." 'Equivalent lengths are shown with maximum number of 90 degree bends at the minimum bend-radius.Different values were obtained by FM and UL due to the differences in minimum bend radius,testing protocol and calculation methods.Please see individual testing standards for more information FLEXHEAQ relative to friction loss(Equivalent Length of Pipe). 8 INDUSTRIES L:ia www.#lexhead.com ....-Aatnre FLEXHEAD SUSPENDED CEILING DETAIL 111 L,f�;I;S��A'Y�WNi�u—0 FlexHead Suspended Ceiling Detail isi,� � Sprinkler ,illrlliY branch line (rr,l � FkaNead q�(�,11 sprinkler drop 1�11 i �i1M Udi.t Ceiling grid mounting bracket ' Adjustable hub (r ,i Suspended r y( t-bar grid (l Ceiling tile0_II,EI 1 0401 Sprinkler head (not included) Sprinkler `y i rp branch line �"111) FlesHead sprinkler drop 1 �A ':�' ' FlexHead Sheetrock Ceiling Detail 1/4"Self-tapping Metal stud screw tYp-2 Adjustable hub mounting bracket 1 E —lI Metal stud ' I Irl` J @�II Sheetrock ceiling Sprinkler head (not included) Each FM approved and UL listed unit is ready to install, pressure-and leak-tested, and comes complete with a flexible stainless steel hose and mounting bracket with adjustable hub. FlexHead 3" Bend Radius per UL Guidelines (2 Bends Shown) FlexHead Shown with 3 Bends 3 i e ,. e kk1 5 ink unr.„ a '•t'1',,,it,-,,.:-,',v,--:',E.,...i,.1.1.i'1,'_": ,1 .• i #t , 2e94 4- i n I{- a".. %iriif k Yfi eir agr4' 'Al•s, �u ^E.•<<u k� �.' .: ^ ." •ill" `.. FLEXHEAD' 9 802.829.6975 -Aatlwre We invented the concept of flexible fire protectionTM HOSE SPECIFICATION SHEET Regular Model Elbow Model 1 inch B0 T to ANSISI B1.20.1 Typ. 304 SS Sch. B 40 Pipe B Weld per ANSI/AWS B2.1-00 Typ: 304 SS * S% Braid Sleeve iii i i New Now. 444•01 iii %sV �!tjt Typ. 304 55 ��it4 `�'_' Corrugated Hose �_ 1 inch true-bore • internal diameter - A provides lower A ; friction loss ,�,_�� A sjj� Tyro. 304 SSto���� ►�S* , Braid to prevent o vim • 444% elongation and improve 'isf��ssi tot44 pressure retention sip.. AISISI iii sss !##%� s 'y NA I` Weld per ������ ANSI/AWS Ossiti B2.1-00 %%%%%%% vy Typ. 304 SS t: C Typ. 304 SS outlet I - spud 1/2 &3/4 inch dil female NPT threads to ANSI 81.20.1 MODEL# A(in.) B(in.) C(in.) D(in.) E(in.) D 2024/2024E 24 3 4.5 1.5,3,4 3.5,5,6 E 2036/2036E 36 3 4.5 1.5,3,4 3.5,5,6 C 2048/2048E 48 3 4.5 1.5,3,4 3.5,5,6 2060/2060E 60 3 4.5 1.5,3,4 3.5,5,6 2072/2072E 72 3 4.5 1.5,3,4 3.5,5,6 • FLEXHEAD DI INDUSTRIESL:: www.flexhead.com ... -Aaawre BRACKET SPECIFICATION SHEET s Multiport Design (For use with T bar and Metal Stud Applications) Model # MP024BKT2 3b878 *Se ar t A et-33 L.3Ri i II 3--'.... ; ow 4 K, r7 P cn Adjustable Design (For use with T bar, Metal Stud and Chicago Grid Applications): standard sizes are 16", 24", and 30" long Model # AD016BKT21, AD024BKT21, ADO3OBKT2 16"/24"/30" 0.290" I. • 1 2.33"/5"/5" 2.33"/575" 2.33"/5"/5" . 7.74"/15.75"/15.75" 2.50" 2.375" 1 1.135" P' , , 2.60" I i I Adjustable Design (For use with T bar, Metal Stud and Chicago Grid Applications): standard size 48" long Model #AD048BKT2 48.2" 42.2" 24" 0III2.362" i > C = c > t >^ ,g P \ N ^ ^ e N r b .T. ` - I r a 375" -''''----S[ • 5" 5" 5" 5" 14.5" 2.50" FLEXHEAD 800.829.6975 INDUSTRIES L ,_Aatkore We invented the concept of flexible fire protectionTM % - :.t1S h. S • -----mo ��' ai fi -, 24';36",48",60",72" hose lengths, 24",36",48",60",72" hose lengths. Rated working pressure 175psi,optional 300psi. Rated working pressure 175psi,optional 300psi. Straight model, Elbow model. Standard 1" I.D.,optional 11/4" I.D. Model #s: see page 8 Model#s:see page 8 *- gp.: *--'- - ' .'"'"-.,',:i•:•.,,,,,,...-7- ,,,ii*,17-i-, " �1� t d ; v ',. . uuvn w war w- I 6 .s 9.�. .�•• s''''',_e.v.Yil , ?t ir ftea I.t i a lai , 24" Multiport Bracket for T-bar Grid or Metal 16"/24"/30"Adjustable Bracket for Stud applications. T-bar Grid,Chicago Grid or Metal Stud applications. Model#:MP024BKT2(standard bracket) Model#s:AD016BKT2/AD024BKT2/AD030BKT2 • is _ i n ,._._._,1_ Hat Channel Bracket System for Metal Stud or 48"Adjustable Bracket for T-bar Grid or Hat Channel applications. Metal Stud applications. Model #:ADO24BKT2 with BKT-HTA Model#:AD048BKT2 v 0 ; , A � Bracket for Confined Space applications Armstrong®TechZone Ceiling Bracket having a concrete deck above the ceiling, for use with Armstrong TechZone Ceiling systems. • Model# U H 2 Available in both 4"and 6"long. Model#s:SP04TZBKT2/SP06TZBKT2 FLEXHEAD Ell INDUSTRIES L,: www.flexhead.com FLEXIBLE SPRINKLER HOSE FITTINGS USE EXAMPLES �... APPROVED ;f} APPROVED 5: mm`` }tP9?Y RH`�, X� j Mier mow, y w £4 .A m^ 2 i tji Suspended Ceilings Exhaust Ducts ® w ,w 111 k APPROVED APPROVED • ,a t i 1 s. 1 f, j ' +v s i CF# a q �', My A£ .ice % F I OII e. Institutional Cleanroom Ceilings Flexible Sprinkler Hose Fittings were developed to satisfy specific needs of the industry, save the industry millions in losses, provide superior seismic protection and promote the installation of sprinklers. They have been evaluated for use by both Underwriters Laboratory and FM. approvals and are tested to approval standards that were independently developed by the testing laboratories. • The first listing for a Flexible Sprinkler Hose Fitting was in 1990. FLEXHEADIli 800.829.6975 NDUSTRIES't� ....e,Aatkore We invented the concept of flexible fire protection' TESTING & APPROVALS 5 , FM GLOBAL TESTING - APPROVAL STANDARD FM1637* FlexHead'series 2000 stainless steel sprinkler connections Hydrostatic Strength Test A sample FlexHead was subjected to a hydrostatic pressure of four(4) times the rated working pressure of 175 psi (1205 kpa) to 700 psi (4825 kpa)for a period of five minutes. The assembly showed no signs of rupture, cracking, permanent distortion, or deterioration of performance characteristics. The FlexHead successfully passed this test. Vibration Test A sample FlexHead was secured to a vibration table. The FlexHead hose was bent in a 90° angle and pressurized to 90 psi (620 kpa)and the mounting bracket and hose were then subjected to a total of 25 hours of severe vibration conditions. After the successful completion of the vibration tests the sample was subjected to the hydrostatic pressure test at 700 psi and showed no signs of deterioration. The FlexHead successfully passed this test. Friction Loss (Equivalent length of pipe) To determine the effect of the FlexHead to the discharge coefficient of the sprinkler, the average friction loss through the FlexHead shall be equated to the theoretical length of nominal 1" diameter schedule 40 sprinkler pipe which would produce the same amount of friction loss. Please see friction loss table. Vacuum Test A sample FlexHead was subjected to a vacuum of 25 inHG for a period of five minutes. After the success full completion of the Vacuum Test the sample was subjected to the hydrostatic pressure test at 700 psi and showed no signs of deterioration. The FlexHead successfully passed this test. Pressure Cycling Test A sample FlexHead was filled with water and bent at a 90°angle and subjected to 20,000 cycles of pressure varying from • 0 psi (0 kpa)to 175 psi(1205 kpa)at a rate of approximately 6 cycles per minute. After the successful completion of the pressure cycling tests the sample was subjected to the hydrostatic pressure test at 700 psi and showed no signs of deterioration. The FlexHead successfully passed this test. Fatigue Test A sample FlexHead was subjected to 50,000 cycles of repeated flexing at a rate of 5 to 30 cycles per minute per section 8.3 of ISO standard 10380, After the successful completion of the fatigue test the sample was subjected to the hydrostatic pressure test at 700 psi and showed no signs of deterioration. The FlexHead successfully passed this test. Head Deployment A sample FlexHead installed in a suspended ceiling was fitted with a sprinkler head and pressurized to 26-175 psi. The sprinkler head was then activated by a heat source at various pressures, and the sprinkler head deployed. The assembly showed no signs of distortion or deterioration of performance on the assembly or sprinkler head. The FlexHead successfully passed this test. • FLEXHEAD INDUSTRIES www.flexhead.com A FLEXIBLE SPRINKLER HOSE WITH FITTINGS FOR COMMERCIAL SUSPENDED CEILINGS Flexible sprinkler hose with threaded end fittings are for use in commercial suspended ceilings. The flexible hoses are to be installed according to the manufacturer's directives. Unless indicated, the hoses have a rated working APPROVED pressure of 175 (1205 kPa). FlexHead Industries, Inc. 56 Lowland St, Holliston, MA 01746 MODEL NPT(in) HOSE ASSEMBLY LENGTH ft(m) 2024/2024E 75 1/2 3/4 2(0.6) This is a standard flexible hose with a pressure rating of 175 psi (1205 kPa). Approval on these 2036/2036E 75 1/2 3/4 3(0.9) models of flexible metal sprinkler hose is limited 2048/2048E 75 1/2 3/4 4(1.2) for use in commercial suspended ceilings, with a 2060/2060E 75 1/2 3/4 5(1.5) ceiling bracket system manufactured by FlexHead 2072/2072E 75 1/2 3/4 6(1.8) Industries Inc. The brackets are identified below. MODEL NPT(in) HOSE ASSEMBLY LENGTH ft(m) This is a standard flexible hose with a pressure rating of 175 psi (1205 kPa). Approval on these 2024E 1/2 2 10.61 models of flexible metal sprinkler hose incorporates 2036E 1/2 3(0.9) a stainless steel elbow welded on the outlet end 2048E 1/2 4(1.2) of hose and are limited for use in commercial 2060E 1/2 5(1.5) suspended ceilings, with a ceiling bracket system manufactured by FlexHead Industries Inc. The 2072E 1/2 6(1.8) brackets are identified below. • MODEL NPT(in) HOSE ASSEMBLY LENGTH ft(m) 2024H 1/2 2(0.6) The "H" designation indicates a pressure rating of 300 psi (2070 kPa). Approval on these models 2036H 1/2 3(0.9) of flexible metal sprinkler hose is limited for use 2048H 1/2 4(1.2) in commercial suspended ceilings, with a ceiling 2060H 1/2 5(1.5) bracket system manufactured by FlexHead 2072H 1/2 6(1.8) Industries Inc. The brackets are identified below. MODEL NPT(in) HOSE ASSEMBLY LENGTH ft(m) The "I" designation indicates an "Institutional" 20241 1/2 2(0.5) flexible hose with a pressure rating of 175 psi 20361 1/2 3(0.9) (1205 kPa).Approval of these models of flexible metal sprinkler hose is limited for use with 20481 1/2 4(1.2) pendant and horizontal sidewall applications with 20601 1/2 5(1.5) a UH-1 ceiling/wall bracket manufactured by 20721 1/2 6(1.8) FlexHead Industries. The different FlexHead Industries, Inc. Brackets are identified as follows: PART NUMBER MPO-24-BKT-2 SP-06-TZ-BKT TZ=Tech Zone 06=Length in inches of bracket ADO-16-BKT-2 AD=Adjustable 16=Length in inches of bracket • ADO-24-BKT-2 ADO-30-BKT-2 BKT=Bracket 24=Length in inches of bracket 30=Length in inches of bracket ADO-48-BKT-2 48=Length in inches of bracket FLEXHEAD® Ill 800.829.6975 INDUSTRIES"L5 We invented the concept of flexible fire protection' TESTING & LISTINGS UNDERWRITERS LABORATORY TESTING - LISTING STANDARD UL2443* FlexHead® series 2000 stainless steel sprinkler connections Hydrostatic Pressure Test Stress-Corrosion Cracking of Stainless Steel Parts Test The sample length is to be measured and then the hydrostatic Austenitic stainless steel parts shall show no evidence of pressure increased to 1.5 times the rated working pressure cracking, delamination, or degradation after being subjected and held for 1 minute. The sample length is then to be to boiling magnesium chloride solution. The exposure is to measured again and the length shall not change by more last for 150 hours. The test samples are to be examined than 0.1 inch/foot of hose length. using a microscope having a magnification of 25X for any cracking, delamination, or other degradation as a result of the Mechanical Strength Test test exposure. A flexible sprinkler hose with fittings installed in its intended position using the anchoring components referenced in the Low Temperature Test for Dry Pipe Systems installation instructions shall withstand a torque of 60 pound- Each sample is to be gradually pressurized with air to feet(81 Nm)applied to the outlet without movement of the a pressure of 40 psig (276 kPa) and then sealed. The fitting outlet, deformation, or fracture. pressurized assembly is then to be placed horizontally in air maintained at a temperature of minus 40°F(minus 40°C)for High Temperature Exposure Test a period of 24 hours. Following the 24 hour low temperature Two samples are to be prepared and subjected to a exposure, the assembly is to be placed in room ambient hydrostatic pressure of twice the rated working pressure. temperature of 73 ±5°F (23 ±3°C)for an additional 24 The samples are then to be allowed to dry and then exposed hour period. There shall be no decrease in the pressure in to an ambient temperature in accordance with Table 10.1 the assembly from the pressure measured before the low for 90 days. Following this exposure, the samples are to be temperature exposure. individually subjected to a hydrostatic pressure of twice the • rated working pressure for 1 minute. Pressure Cycling Test The samples are to be connected to a pressure cycling Vibration Test apparatus, filled with water and vented of all air. The internal Samples are to be vibrated for a period of 30 hours at pressure is to be cycled 3,000 times from 0 psig (0 kPa) frequencies ranging from 18 to 37 Hz. During and after to twice the rated working pressure to 0 psig (0 kPA)at being subjected to the required vibration, the samples are to an approximate rate of 10 cycles per minute. During the be examined for signs of leakage, rupture, or movement of pressure cycling, observations are to be made for evidence of the outlet fitting affecting the performance of the flexible leakage or physical damage. hose assembly. Vacuum Test Equivalent Length Determination Flexible sprinkler hose with fittings shall withstand a vacuum A sample of each length shall be tested in straight lengths of minus 8.84 psi (minus 61 kPa)without collapse, leakage, and with the maximum number of minimum radii bends or other deterioration of the flexible sprinkler hose and fitting referenced in the installation instructions. The calculated performance characteristics. pressure loss from the piezometers, corrected for the inlet and outlet velocities, are to be subtracted from the test High Pressure Flow Test sample results to obtain a pressure drop for the fitting. Flexible sprinkler hose with fittings and its anchoring Using the Hazen-Williams coefficient of friction of 120, the components shall maintain the attached sprinkler in the equivalent length, in feet(m)of pipe, is to be calculated. intended operating position while the sprinkler discharges water at 90 percent of the rated pressure of the flexible Salt Spray Corrosion Test sprinkler hose. Ferrous flexible sprinkler hose with fittings and ferrous anchoring components not protected with a coating shall Fatigue Test(Limited Flexibility) withstand an exposure to a salt spray atmosphere for 10 days Flexible hose with fittings shall withstand without leakage without exhibiting any incipient corrosion. or damage repeated flexing in a direction parallel to the axis of the end fittings. The number of flexing cycles shall be • 100 cycles. FLEXHEAiD Ell INDUSTRIES-L.0 www.flexhead.com TESTING & LISTINGS UNDERWRITERS LABORATORY TESTING - VENF.EX5269 Flexible Sprinkler Hose with Fittings See General Information for Flexible Sprinkler Hose with Fittings RATED MAX NOM INLET ASSEMBLY EQUIVALENT PRESSURE AMBIENT BY OUTLET LENGTH MAX NO. MIN LENGTH OF iin. MODEL TEMP SIZE OF BEND SCHEDULE 40 FLEXIBILITY 90°BENDS RADIUS STEEL PIPE TYPE psig F° in. ft.(mm) in. (C=120),ft 2024 175 300 1 by 1/2 2 3 3 11 Limited 2036 175 300 1 by 1/2 3 3 3 16 Limited 2048 175 300 1 by 1/2 4 4 3 24 Limited 2060 175 300 1 by 1/2 5 4 3 29 Limited 2072 175 300 1 by 1/2 6 4 3 35 Limited 2024 175 300 1 by 3/4 2 3 3 12 Limited 2036 175 300 1 by 3/4 3 3 3 18 Limited 2048 175 300 1 by 3/4 4 4 3 23 Limited 2060 175 300 1 by 3/4 5 4 3 29 Limited 2072 175 300 1 by 3/4 6 4 3 32 Limited 2024H 300 300 1 by 1/2 2 3 3 11 Limited 2036H 300 300 1 by 1/2 3 3 3 16 Limited 2048H 300 300 1 by 1/2 4 4 3 24 Limited 2060H 300 300 1 by 1/2 5 4 3 29 Limited 2072H 300 300 1 by 1/2 6 4 3 35 Limited • 2024H 300 300 1 by 3/4 2 3 3 12 Limited 2036H 300 300 1 by 3/4 3 3 3 18 Limited 2048H 300 300 1 by 3/4 4 4 3 23 Limited 2060H 300 300 1 by 3/4 5 4 3 29 Limited 2072H 300 300 1 by 3/4 6 4 3 32 Limited 2024E 175 300 1 by 1/2 2 3 3 19 Limited 2036E 175 300 1 by 1/2 3 3 3 23 Limited 2048E 175 300 1 by 1/2 4 4 3 27 Limited 2060E 175 300 1 by 1/2 5 4 3 32 Limited 2072E 175 300 1 by 1/2 6 4 3 35 Limited 2024E 175 300 1 by 3/4 2 3 3 18 Limited 2036E 175 300 1 by 3/4 3 3 3 23 Limited 2048E 175 300 1 by 3/4 4 4 3 23 Limited 2060E 175 300 1 by 3/4 5 4 3 29 Limited 2072E 175 300 1 by 3/4 6 4 3 32 Limited 2024HE 300 300 1 by 1/2 2 3 3 19 Limited 2036HE 300 300 1 by 1/2 3 3 3 23 Limited 2048HE 300 300 1 by 1/2 4 4 3 27 Limited 2060HE 300 300 1 by 1/2 5 4 3 32 Limited 2072HE 300 300 1 by 1/2 6 4 3 35 Limited 2024HE 300 300 1 by 3/4 2 3 3 18 Limited 2036HE 300 300 1 by 3/4 3 3 3 23 Limited 2048HE 300 300 1 by 3/4 4 4 3 23 Limited 2060HE 300 300 1 by 3/4 5 4 3 29 Limited 2072HE 300 300 1 by 3/4 6 4 3 32 Limited These flexible sprinkler hoses with fittings are intended to be installed in accordance with the manufacturer's installation instructions. • Copyright©2009 Underwriters Laboratories Inc.° Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc. The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product. FiEXHEAI 800.829.6975 INDUSTRIES is) ... ,.4atkore We invented the concept of flexible fire protectionT" r z e^�-�i•,a.,},v �ar3 rxgi5 -'*.+a.e ,.', c e:;, rt a. a t" re ee4 e 11 ef 1- )A @/EQUIPMENT' ANCHORAGE & SEISMIC ENGINEERING www..QuFpmontanchorago.cam FLEXHEAD INDUSTRIES D. R LA BRIE I .00 ma n-0788 SHEET FLEXHEAD SPRINKLER CONNECTIONS I MODEL # 2024, 203fi, 2048, 20fi0r 2072 DATE 9rr 2 e SEISMIC ANCHORAGE PRE-A.APRO'JED DETAIL .EILINS MCLNT Office of Statewide Health Planning and Development ANCHORAGE PRE-APPROVAL I,r $,. G.6.WT._ �h�� DA LESS.MAX. NA EXISTING WATER SUPPLY LINE • P^.y:'2 ,` PER NIT'A GUIDE LINES lb GA.6AI.VANIZED (E3(ENGINkex OF RECORD) SHEET METAL MI N. 20 GA.GALVANIZED FLF.XHwAD BRACKET • MEET METAL TAMPER RESISTANT SNAPS ONTO m SCREWS(I)ON EACH T-BAR CEILING ■� — ENE) -PROVIDED BY _ I FLEXIIEAD III IUI . T-BAR CEILING GRID N SPRINKLER HEAD 3l8'BOLT WITH (B Eti Y EN61Nt Of RECORD) OT1 R5) BACKING NUT GENERAL NOTES: ELEVATION I. ANCHORAGE DESIGN PER 2001 GALIFORNIA BUILDING CODE - SECTION I613A AND ASGE 1-05 SECTIONS 12 AND 13. ALLOWABLE STRESS DESIGN 15 USED. HORIZONTAL FORGE (Eh) = 2.43 HP(Sys = 1.93, I p = 1.5,op= 2.5, R p= 25) VERTICAL FORGE (Eu) = 021 kip 2. ENGINEER OF RECORD FOR THE BUILDING SHALL PROVIDE SUPPORT STRUCTURE DESIGNED TO SUPPORT WEIGHTS AND FORGES SHOWN. 3. ENGINEER OF RECORD TO VERIFY CONNECTION HILL PERMIT ADEQUATE DISPLAG a T IN ALL DIRECTIONS. i * I'iii APPROVED " T 7O Fixed Equipment Anchorage i••+'a.r t e (may Off�ca o1 Statowlde Health Panning ano Oevelopmor�t CZ, OPA-0672-07 Na. 3566 T _m fig'4` 5� �P � W EXP. 3-31-2010 i' tr,)arua.ro * ffgl24/0.N4 t , es • tf1:1 Of c kvl s Rovievw d 3r:nitU aiae grams FLEXHEAD 8 INDUSTRIES"Lw www.flexhead.com yr i,4 '° 1t I A x i x 'fh 6 v t i i C ��YY C� � � � C � � 3 � 5 ,� $ � i 4 h4 L'b " ,S 6 Ri.C " '" { i , 4 i, L i' 3 • ,,..,,,,.„,,,,,,:4:,,,,a::,,,,„1,i;:::6,,i.,,o. :=i2;;:;;;,i.:;i..:::::::),4F,i,,,::,44:4L: :iu.....:!:t;::v,.,.. In_:, ir.4;;t:uro,,,,,i.,.7:::.1.,::F.,,,E,E1,:i.:::i::::zitalky4K,t,,,,,,-:2,aL. .E.•,;,, ,,,:!,,,..,_...:,..,i!,:4•114z, A,g fq EQUIPMENTANCHORAGE & t7P.M21G ENGINEERING ING www.equipmfontanchorage.com FLEXHEAD INDUSTRIES pea R L' BRIE FLEXHEAD SPRINKLER CONNECTIONSJoe lea LA MODEL # 2024E 2036E 2048E, 2060& 2072E �ll 9 co, ,�2 , ,s r SEISMIG ANCHORAGE PRE-APPROVE)DETAIL AT 5HE ETRWGK CEILING GEILI146 MOAT Office of Statewide Health Planning and Development ANCHORAGE PRE-APPROVAL EXISTING WATER SHYLY LINE PER NEPA GUIDE LINES (BY ENGINEER OF RETARD) G 6.WT. 9.9 LBS.MAX. 90 DEGREE ELBOW 110 l_I, :.111:4 %%.`.:��. ;y. . � �1, I6 GA.GALVANIZE). SHEET PETAL I/4"SELF TAPPING SGREh6 20 6A.GALVANIZED (2.)ON EACH END SHEET METAL !� '�- 6YPSUM BOARD CEILINGNN WITH METAL(OR WOODEN) SPRINKLER HEAD 3/8'BOLT WITH FRAMING tlEMBER ENGINEER OF RECORD} Or OTHERS} BALKING NIT El FVATIOti GENERAL NOTES: 1. ANCHORAGE DESIGN PER 2007 GALIFORNIA BUILDING CODE - SECTION I6I3A AND ASGE 1-05 SECTIONS 12 AND 13. ALLOWABLE STRESS DESIGN 15 USED. HORIZONTAL FORCE (Eh) = 2.43 Ntp(5p5 = I.13, I p= 15,a p= 25,R p= 2.5) VERTICAL FORGE(F.) = 0.21 Hp 2. ENGINEER OF RECORD FOR THE BUILDING SHALL PROVIDE SUPPORT STRUCTURE DESIGNED TO SUPPORT HEIGHTS AND FORGES SHOWN. 3. ENGINEER OF RECORD TO VERIFY" CONNECTION HILL PERMIT ADEQUATE DISPLACE I IN ALL DIRECTIONS. y f APPROVED ;' ' r+, Ap Fixed Equipment Anchorage j i . " 1 I'a; I1y °moo of 9,atawldi]Health Pl�nlna and Dnvafopment ti .... 1 * OPA-0676-07 No. 3566 -eai n:..$,n,..la Manager o` EXP, 3-31.2010 $ r " E (°,6)`°°""'° • *� ,r 4/24/04 s... \* ;917 OF C AI�Fa@� weir j�.C 1�+Y fiavlawad sy<a,*h . Ike W2e10a FLEXHEAL E.M..%829I'r:5 INDUSTRIES"L.") 1' LZatkore We invented the concept of flexible fire protection' Alplinomp.d txtli P WIN ppp: Jaen C ® US Underwriters Laboratories Inc." LISTED (r'irgh rcY June 21, 2001 FlexHead Industries Mr. Norm MacDonald 56 Lowland St. Holliston, MA 01746 Our Reference: File EX5269 Subject: FlexHead Flexible Sprinkler Hose Fittings Installed Onto Dry Wall Ceiling Grid Dear Mr. MacDonald: • This letter is in regard to the subject. Base upon review of the FlexHead UL Listed flexible sprinkler hose fitting system, installation onto a dry wall ceiling grid is acceptable when the ceiling-mounted bracket is screwed to a rigid surface. Self-tapping screws are used to affix the FlexHead mounting bracket to the surface, using the four ports provided which are pre- drilled onto the mounting bracket. Very truly yours, EMIL W. MISICHKO (Ext. 42036) Engineering Group Leader Conformity Assessment Services Department 3011CNBK Emil W. Misichko@us.ul.com A not-for-profit organization dedicated to public safety and • committed to quality service :111 FLEXHEAD I N D U S T R I E S 2;) www.flexhead.com .. .^atkore • y5 National Fire Protection Association Nf PA M Barter2W)WI Ph '�t7-770-tarch 3 K•rora}9t7.7704)7l •wwvolfp•.ur, November 15,2006 Mr.Norman MacDonald President Flexl lead Industries,Inc. 56 Lowland Street Holliston,MA 01746 Fax: 508-893-6020 Dear Mr. MacDonald, This letter is in response to your email dated November 13,2006 which discussed listed flexible sprinkler hoses,specifically Flextlead. Your question relates to the acceptability of listed technology which was not specifically addressed in previous editions of NFPA 13, including the 1999 and 2002 editions. NFPA 13, 1999 Section 1-2 and NFPA 13,2002 Section 1.6 provide specific text that addresses new technology. It is the intent of the current and previous editions of NFPA 13 to allow the use • of listed technologies where they are not specifically addressed in NFPA 13. The base requirement is that they be installed in compliance with all of the listing requirements and manufacturers' instructions. These statements have been provided by the technical committees to address the very situation that you have described. In essence,where a new technology is developed,tested and listed as acceptable for automatic fire sprinkler use it can be utilized in accordance with NFPA I)with no additional requirements other than those in the listing and manufacturers' instructions. In summary it is the intent of NFPA 13 to permit the use of technologies,equipment and materials not specifically addressed in NFPA 13 where they are specifically listed for fire sprinkler use and where they have been installed in accordance with the listing requirements and the manufacturers' instructions. Please he aware that this response does not constitute a Formal Interpretation as explained in the Important Notice below. R - fully, f ({ 2erdt. tristtan D .•;P.E. Principal . e Protection En_incce NFPA 13 Sta ,t. s• File: NFPA 13 Important Notice: This correspondence is not a Formal Interpretation issued pursuant to NFPA regulations. Any opinion expressed is the personal opinion of the author,and does not • necessarily represent the official position of the NFPA or its Technical Committees. In addition, this correspondence is neither intended,nor should be relied upon,to provide professional consultation or services. ...--------_-_----.-... FLEXHEAUl 800.829.6975 INDUSTRIES L El ... „_Aatkore We invented the concept of flexible fire protectionTM' EARTHQUAKE CASE STUDY ONE STORE STAYS OPEN AFTER EARTHQUAKE FlexHead flexible sprinkler systems have been protecting exhaust ducts in • rr semi-conductor/electronics facilities for more than fifteen years with no reported failures or leaks, and no sprinkler related downtime. During normal operation, patented FlexHead technology contributes to productivity by allowing the process to continue even during routine maintenance. Less than a year after SimplexGrinnell installed FlexHead flexible sprinklers in a new department store in Bayshore Mall, Mother Nature tested Eureka, CA, with a 6.5 earthquake. —`-= This store's fire protection system remained intact and functional throughout the Saturday afternoon quake and its aftershocks, and the store opened for business Sunday morning. Unfortunately, the shaking breached the hard-pipe automatic sprinkler system protecting the rest of the mall, closing the 76 other stores for clean-up and repairs. The Jan. 9, 2010 quake, which was centered about 25 miles off-shore from Eureka, sent shoppers scrambling at about 4:30 p.m. But after picking up fallen stock, minor cleanup, and the official safety inspection, this store re-opened the following morning. The rest of the mall remained closed until January 13, with damage estimated at$6 million, SimplexGrinnell installed the FlexHead-equipped system in May 2009. Although FlexHead products meet With FlexHeads' the stringent Los Angeles seismic qualification (AC 156), the decision to use them was strictly economic. we were able to "The earthquake [rating] didn't have anything to do with it,"said Tim Madura, Service Contract Sales for SimplexGrinnell, do it in one trip, • and When we "It was economics; though, of course, I'm sold on the earthquake thing now! I had to be very competitive, and I knew I had to be low-priced. Using FlexHead was how we could left the job, price the job low enough to get it."The new department store was taking over an existing, 40,000-square-foot anchor-store attached to the main mall, gutting it in order to establish we were done their own layout with new walls, ceilings and fixtures. The existing sprinkler system, which remained in place, was a typical 10x12 spacing with hard-pipe drops hanging down. way ahead of "The ceiling height changed [from the previous configuration], so we removed the drops and everybody else, installed the FlexHeads with the sprinkler heads already attached," Madura said. "We wire- tied them up to the side of the drops until the ceiling went in. "Prior to the grid going in, the And to me, fire department did their 200-pound test for two hours with all our FlexHeads installed, and they were fine with that. Then we waited for the grid, and chased the grid people in there," that's just he continued. tremendous! Madura estimates that using FlexHeads saved at least half of the time, cost and aggravation that hard-pipe installations incur. In addition to reducing the need for cutting and threading to a bare minimum, and completely eliminating the back-and forth adjustments typical to hard-pipe installation, using FlexHead also required only one drain-down and one 200-pound test. "Some agencies will make you come back after you've cut in your drops," he explained. "But here, we drained it one time, put the heads on, and had it tested. We didn't have to drain each drop again or hard-pipe over to the center of tile. All we needed to do was remove the wire-tie, move the FlexHead over to where it was going to be, put our bracket on, put our tile in, put our escutcheon in and we were done." The ability to work fast and efficiently also substantially improved another dimension of SimplexGrinnell's job cost. • "If we had used hard pipe, we would have had an additional trip up there(four hours away) just to put the escutcheons on, which would have been added cost to us," Madura said. FLEXHEAD INDUSrRIES14 www.flexhead.com „�atkore • : EARTHQUAKE CASE STUDY (CONT'D) AND WARRANTY "With FlexHeads, we were able to do it in one trip, and when leak, and with FlexHead, it's only where you're connected to we left the job, we were done way ahead of everybody else. the hard pipe and where your sprinkler head is. Also, because And to me, that's just tremendous!" they're constructed of stainless steel, I think the FlexHeads are just a stronger product." This job included about 500 sprinkler heads, none of which were compromised by the earthquake. Even the escutcheons "I was on a service truck for a long time," he concluded. remained in place. "And I've always had the mindset that I didn't want to give my customers something that wasn't the best or just because "This store didn't lose any escutcheons," Madura said, "and it's new to the market. Part of that is that I didn't want to these were concealed, flat plate sprinkler covers. The other have to come back and fix it down the road, and I've always stores got beat up pretty badly, and, of course, lost very many operated that way. So I try to give my customers the best escutcheons." Madura wasn't always sold on flexible sprinkler product that's out there, and this experience has made me connections. He says that he needed to wait until there was a very confident in FlexHead." track record of how well they held up over time. When he was ready to use flexibles, he chose FlexHead because of the quality and the design of the products. Also, because they're constructed of "FlexHeads are one solid piece, whereas some others have stainless steel, I think the FlexHeads a removable end. To me, that's two extra potential leaks," he said. "Where anything screws together, you have a potential are just a stronger product t; a: FLEXHEAD PRODUCTS LIMITED WARRANTY Flexhead Industries, Inc. warrants that its products will be free from defects in materials and workmanship under normal conditions of use and service for a period of one year from date of sale. Our obligation under this warranty is limited to repairing or replacing any product that • is returned to us with transportation charges prepaid within one year after the date of original sale and that our examination shows to our satisfaction to have been defective in materials or workmanship under normal conditions of use and service.The decision as to whether to repair or to replace any product shall be made by us, and any repair shall be made at our facility. Notwithstanding the foregoing, the following are specifically excluded from the coverage of this warranty: (a)the sprinkler head of any Flexhead Industries, Inc. product, but Flexhead Industries, Inc. hereby assigns to the original purchaser of any such product the right to enforce the warranty, if any, issued by the manufacturer of such sprinkler head (b)defects resulting from ordinary wear and tear, including,without limitation,the replacement of the so-called poly bag components of any Flexhead Industries, Inc. product (c)products that have been altered in any manner by the buyer or by anyone other than Flexhead Industries, Inc. (d) products that have been subjected to misuse, abusive use, or damage by accident or casualty (e) products that have been installed or used in a manner contrary to our specifications, instructions or recommendation (f) products that have been installed or used in a manner that is not in compliance with all applicable requirements of any code, law, regulation or rule of any federal, state or local governmental or industry authority; and (g)products that have not been inspected and maintained in accordance with our specifications, instructions or recommendations, including,without limitation,our recommendations as to following the inspection and maintenance standards published by Factory Mutual Research Corporation(FMRC)and the National Fire Protection Association (NFPA);and (h)products that have been affected by Microbiologically Influenced Corrosion (MIC). This warranty is not assignable and shall benefit only the original purchaser of a Flexhead Industries, Inc. product. If any provision hereof or any portion of any provision shall be held invalid,the remainder of this Limited Warranty shall not be affected thereby, and all provisions of this Limited Warranty shall remain valid and in full force and effect to the fullest extent permitted by law, THIS WARRANTY IS IN LIEU OF ALL IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO,WARRANTIES OF MERCHANTABILITY AND WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE. NOTWITHSTANDING ANY PROVISION TO THE CONTRARY HEREIN OR ANY APPLICABLE LAW TO THE CONTRARY, IN NO EVENT SHALL FLEXHEAD INDUSTRIES, INC. BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES UNDER ANY CIRCUMSTANCES WHATSOEVER,WHETHER ARISING FROM ANY BREACH OF THIS . LIMITED WARRANTY OR OTHERWISE ARISING FROM OR IN CONNECTION WITH THE USE OR OPERATION OF, OR ANY DEFECT IN, ANY FLEXHEAD INDUSTRIES, INC. PRODUCT,OR OTHERWISE.The risk of damages from any breach of warranty with respect to injury to any person will be born by the purchaser of Flexhead Industries, Inc. product. FLEXHEAD El 800.829.6975 INDUSTRIES-1t3 ,r. F i.�,..- .... ..�,n2t .,^ tSK ✓h , .. -T.: .,R4.;>-. __ .rim .��- `4'T"° ::"�^' R,'f 56 Lowland Street Holliston, MA 01746 PHONE / 508-893-9596 TOLL FREE / 800-829-6975 www.flexhead.com allied UNISTRUT R g FLEXHEAD TUBE& CONDUIT AFC RIBBON r t )U TR E S 1 Herita ePlastics' u Columbia-MBF"" copy Ridge tine-" t)NISTI UT° ���;,) Pipe Manufacturins] OAstrue loA wire.conduit rECTRONTirbe 5prinkFLEX' M KfIF'TEC I ,.C2D15 Atkore International.Inc.All-fights reserved.FXH-L-4005-1501 1 Accessories Fire Sprinkler Accessories • Sprinkler Identification Signs FPPI's Sprinkler Identification Signs are manufactured of aluminum, SPRINKLERSpainted white then printed with "fade resistant"red ink. Each sign is G yr a drilled for easy installation and is plastic coated to prevent scratching of �� finish during shipment and final installation. Designed in accordance with NFPA requirements. 1 ILD Part No. Description {,� l� 02-002-00 Blank Sign w/border 6" x 2" Box Qty. 100 02-006-00 Air Control 6" x 2" 100 j 02-010-00 Air Line 6"x 2" 100 co 0 02-014-00 Alarm Line 6"x 2" 100 Oa 02-018-00 Alarm Test 6"x 2" 100 .p. AUTOMATIC rR N R 02-022-00 Anti-Freeze System 6"x 2" 100 co StiliT.OFF VALVE y 02-023-00 Anti-Freeze System 5"x 7" 100 N 02-024-00 Auto Sprinkler Shut-Off 12"x 10" 100 LOCATED N. 6" 02-026-00 Auxiliary Drain x 2 100 {c OPPOSITE THIS SION 02-034-00 Control Valve 6"x 2" 100 * 02-036-00 Control Valve 4" x 6" 100 -a 02-037-00 Control Valve 5"x 7" 100 0 02-038-00 Control Valve 9"x 7" 100 02-042-00 Drain 6"x 2" 100 a FIRE SPRINKLER 02-046-00 Drain Valve 6"x 2" 100 02-049-00 Drum Drip 6"x 2" 100 RISERINSIDE 02-050-00 Dry Standpipe 6"x 2" 100 02-051-00 Fire Dept. Connection 6"x 2" 100 02-052-00 FDC w/Arrow Label 12"x 10" 100 TEM 02-053-00 Excess Pressure Pump 6"x 2" 100 - 'e t1` 9' 02-054-00 Entire System 6" x 2" 100 ANTI-FREEZE ,i 02-055-00 Fire Alarm Bell 9"x 7" 100 SYSTEM « i, 4 ' ,; = 02-056-00 Fire Alarm Bell 7" Round 100 ;: . ..a-=� -.tea y , i. - =;rl.P. 02-057-00 911 Fire Alarm Bell 7" Round 100 l° ` r1-� = j 02-058-00 F.S. Valve Do Not Close 6"x 2" 100 x. -.n.,..,.- .. .; �� '3t, tl""`: 02-060-00 Fire Sprinkler Riser Inside 6"x 2" 100 t °e`° "' ' 02-062-00 From City Main 6"x 2" 100 rEM . i nM1111,w,rr4 I 'AT'jai=i. 02-064-00 General Information 9"x 7" 100 ' rs•-3 •• = 02-066-00 In This Building 6" x 2" 100 02-070-00 In This Section 6" x 2" 100 02-074-00 Inspectors Test 6" x 2" 100 02-077-00 Hydraulic System 5"x 7" 100 III 02-081-00 Hydraulic System 8Ys" x 11" 100 02-083-00 Low Point 6"x 2" 100 02-082-00 Main Control 6"x 2" 100 02-086-00 Main Drain 6"x 2" 100 02-091-00 Multi-use System, Warning 5"x 7" 100 12 Accessories I �� �.`1 E,`j FP i Fire Sprinkler Accessories • Sprinkler Identification Signs (continued) ""' ' _ Part No. Description Box Qty. d}� �6:7 02-092-00 Normally Closed 6" x 2" 100 a ; 02-096-00 Normally Open 6" x 2" 100 02-098-00 Open Sprinkler 6" x 2" 100 02-100-00 Open Sprinkler Control 6"x 2" 100 .• ■+-�.Om. 02-105-00 Open Valve 6"x 2" 100 '''- t„ +! 0... . . . , �2'. . .. .ram. ;i 02-108 00 Sprinkler Control Valve 6"x 2" 100 ` "-.= : .rZ 02-110-00 Sprinkler Drain Valve 6" x 2" 100 ''"�i`�'��" E e O 02-111-00 Sprinkler Drain Room 6"x 2" 100 :ham. ' ' "°° * 0 02-112-00 Sprinkler Valve Room 6" x 2" 100 el. 02-114-00 Sprinklers Throughout Bldg. 12" x 10" 100 , T Apr ftrat#G c. .R. .".Y ;::!T"t..i' g 02-116-00 Standpipe System 6"x 2" 100 ";."'` .."`"' ' PA3:.kMY I"1 PM`rJH YL 02-120-00 Test& Drain 6" x 2" 100 ac r"• uacs ears. • pps..raL-TC rf]7.la.OW 02-124-00 Test Valve 6"x 2" 100 ...aw co r''reen3. .yt S �xsss+�s t ..ti...d iea ric CV 02-128-00 Water Motorline 6"x 2" 100 `='•ie" "" "`415TLV N ,•/•,, . ..�,i. s..TcI CO 02-132-00 Wet Standpipe 6" x 2" 100 """Yt44`"",ti.cw ar ruc Cr -. -,;cm cTC w>ri.-:: GVA 02-133-00 Wet Standpipe Shutoff 6" x 2" 100 ° =,: go 00Y.NroPolar rxas,r+G er I 0• Yyi.R :a s.:Y 4H.,. a #4''kb:y Sprinkler Identification Signs, Decals Printed with "fade resistant" red ink on white vinyl. .r..-=, Part No. Description Box Qty. 02-027-00 Auxiliary Drain, Decal (100/roll) 6"x 2" 1 roll ..' 02-035-00 Control Valve Decal (100/roll) 6"x 2" 1 roll ousFopwaLlt L1Mt ' f 02-040-00 Do Not Hang Decal (100/roll) 21/4' round 1 roll 02-061-00 Fire Sprinkler Line Decal (100/roll) 6"x 2" 1 roll 02-063-00 Fire Sprinkler Riser Room Decal 6"x 18" 25 02-065-00 General Information Decal 9"x 7" 100 rim , =� 02-075-00 Inspectors Test Decal (100/roll) 6" x 2" 1 roll 02-079-00 Hydraulic System Foil Decal 5" x 7" 100 i ; tz .. g s ; 02-080-00 Hydraulic System Decal 5" x 7" 100 i o-r� ryx opao 02-087-00 Main Drain Decal (100/roll) 6"x 2" 1 roll I 02-090-00 Multi-use System Warning Decal 5"x 7" 100 i" ,r • 13 VICO Fire & Building IIIProducts Technical Services: Tel: (800) 381-9312/ Fax: (800)791-5500 BlazeMaster® TFP-401 One Step Solvent Cement MSDS (Material Safety Data Sheet) MSDS No: TYCO10E6 Issue Date: 11 May 2006 SECTION 1 PRODUCT AND COMPANY IDENTIFICATION Trade Name: BLAZEMASTER CPVC CEMENT TFP-401 Product Use: Cement for CPVC Pipe Formula: CPVC Resin in Solvent Solution Synonyms: CPVC Plastic Pipe Cement Firm Name & TYCO c/o OATEY CO. 4700 West 160th Street P.O. Box 35906 Mailing Address: Cleveland, Ohio 44135, U.S.A. http://www.oatey.com Oatey Phone Number: (216) 267-7100 or (800) 321-9532 Emergency Phone For Emergency First Aid call 1-877-740-5015. For Numbers: chemical transportation emergencies ONLY, call Chemtrec at 1-800-424-9300. Outside the U.S. 1-703-527-3887. Prepared By: Corporate Director - Safety and Environmental Compliance Preparation Date: May 11, 2006 • SECTION 2 COMPOSITION/INFORMATION ON INGREDIENTS INGREDIENTS: %wt/wt: CAS NUMBER: ACGIH TLV TWA: OSHA PEL TWA: OTHER: Acetone 5 - 15% 67-64-1 500 ppm 1000 ppm 750 ppm STEL Tetrahydrofuran 40 - 55% 109-99-9 50 ppm(skin) 200 ppm 25 ppm (Mfg) 100 ppm STEL Methyl Ethyl Ketone 5 - 15% 78-93-3 200 ppm 200 ppm None 300 ppm STEL Cyclohexanone 5 - 15% 108-94-1 20 ppm(skin) 50 ppm None 50 ppm STEL CPVC Resin 15 - 30% 68648-82-8 10 mg/m3 None None (Non-hazardous) Established Amorphous Fumed Silica 1 - 5% 112945-52-5 10 mg/m3 None None (Non-hazardous) Established OSHA Hazard Classification: Flammable, irritant, organ effects SECTION 3 HAZARDS IDENTIFICATION Emergency Overview: Red liquid with an ether-like odor. Extremely flammable liquid and vapor. Vapors may cause flash fire. May cause eye and skin irritation. Inhalation of vapors or mist may cause respiratory irritation and central nervous system effects. Swallowing may cause irritation, nausea, vomiting, diarrhea and kidney or liver disorders. Aspiration hazard. May be fatal if swallowed. Symptoms may be delayed. 4111 Page 1 of 6 JUNE, 2008 TFP1992 Page 2 of 6 TFP1992 SECTION 4 FIRST AID MEASURES • CALL 1-877-740-5015 Skin: Remove contaminated clothing immediately. Wash all exposed areas with soap and water. Get medical attention if irritation develops. Remove dried cement with Oatey Plumber's Hand Cleaner or baby oil. Eyes: If material gets into eyes or if fumes cause irritation, immediately flush eyes with plenty of water until chemical is removed. If irritation persists, get medical attention immediately. Inhalation: If symptoms of exposure develop, remove to fresh air. If breathing becomes difficult, administer oxygen. Administer artificial respiration if breathing has stopped. Seek immediate medical attention. Ingestion: DO NOT INDUCE VOMITING. Rinse mouth with water. Never give anything by mouth to a person who is unconscious or drowsy. Get immediate medical attention by calling a Poison Control Center, or hospital emergency room. If medical advice cannot be obtained, then take the person and product to the nearest medical emergency treatment center or hospital. SECTION 5 FIRE FIGHTING MEASURES Flashpoint / Method: 0 - 5 Degrees F. (-18 - -15 Degrees C) / PMCC Flammability: LEL = 1.8 % Volume, UEL = 11.8 % Volume Extinguishing Use dry chemical, CO2, or foam to extinguish fire. Cool fire Media: exposed container with water. Water may be ineffective as an extinguishing agent. Special Fire Firefighters should wear positive pressure self-contained Fighting breathing apparatus and full protective clothing for fires in Procedure: areas where chemicals are used or stored Unusual Fire and Extremely flammable liquid. Keep away from heat and all Explosion sources of ignition including sparks, flames, lighted Hazards: cigarettes and pilot lights. Containers may rupture or explode in the heat of a fire. Vapors are heavier than air and may travel to a remote ignition source and flash back. This product contains tetrahydrofuran that may form explosive • organic peroxide when exposed to air or light or with age. Hazardous Combustion will produce toxic and irritating vapors including Decomposition carbon monoxide, carbon dioxide and hydrogen chloride. Products: SECTION 6 ACCIDENTAL RELEASE MEASURES Spill or Remove all sources of ignition and ventilate area. Stop leak if it Leak can be done without risk. Personnel cleaning up the spill should Procedures: wear appropriate personal protective equipment, including respirators if vapor concentrations are high. Soak up spill with an inert absorbent such as sand, earth or other non-combusting material. Put absorbent material in covered, labeled metal containers. Prevent liquid from entering watercourses, sewers and natural waterways. Report releases to authorities as required. See Section 13 for disposal information. SECTION 7 HANDLING AND STORAGE Handling: Avoid contact with eyes, skin and clothing. Avoid breathing vapors or mists. Use with adequate ventilation (equivalent to outdoors). Wash thoroughly after handling. Do not eat, drink or smoke in the work area. Keep product away from heat, sparks, flames and all other sources of ignition. No smoking in storage or use areas. Keep containers closed when not in use. Storage: Store in a cool, dry, well-ventilated area away from incompatible materials. Keep containers closed when not in use. Other: "Empty" containers retain product residue and can be hazardous. Follow all MSDS precautions in handling empty containers. Do not cut or weld on or near empty or full containers. 4111 TFP1992 Page 3 of 6 • SECTION 8 EXPOSURE CONTROLS/PERSONAL PROTECTION Ventilation: Open doors & windows. Provide ventilation capable of maintaining emissions at the point of use below recommended exposure limits. If used in enclosed area, use exhaust fans. Exhaust fans should be explosion-proof or set up in a way that flammable concentrations of solvent vapors are not exposed to electrical fixtures or hot surfaces. Respiratory For operations where the exposure limit may be exceeded, a NIOSH Protection: approved organic vapor respirator or supplied air respirator is recommended. Equipment selection depends on contaminant type and concentration, select in accordance with 29 CFR 1910.134 and good industrial hygiene practice. For firefighting, use self-contained breathing apparatus. Skin Rubber gloves are suitable for normal use of the product. For long Protection: exposures chemical resistant gloves may be required such as 4H(tm) or Silver Shield(tm) to avoid prolonged skin contact. Eye Safety glasses with side shields or safety goggles. Protection: Other: Eye wash and safety shower should be available. SECTION 9 PHYSICAL AND CHEMICAL PROPERTIES Boiling Point: 151 Degrees F / 66 Degrees C Melting Point: Not applicable Vapor Pressure: 145 mmHg @ 20 Degrees C Vapor Density: (Air = 1) 2.5 Volatile Components: 70 - 80% Solubility In Water: Negligible pH: Not applicable Specific Gravity: 0.98 +/- 0.02 @ 20 Degrees C Evaporation Rate: (BUAC = 1) = 5.5 - 8.0 Appearance: Red Liquid Odor: Ether-Like • Will Dissolve In: Tetrahydrofuran Material Is: Liquid SECTION 10 STABILITY AND REACTIVITY Stability: Stable. Conditions To Avoid: Avoid heat, sparks, flames and other sources of ignition. Hazardous Combustion will produce toxic and irritating vapors Decomposition including carbon monoxide, carbon dioxide and hydrogen Products: chloride. Incompatibility/ Oxidizing agents, alkalis, amines, ammonia, acids, chlorine Materials To Avoid: compounds, chlorinated inorganics (potassium, calcium and sodium hypochlorite) and hydrogen peroxides. May attack plastic, resins and rubber. Hazardous Polymerization: Will not occur. SECTION 11 TOXICOLOGICAL INFORMATION Inhalation: Vapors or mists may cause mucous membrane and respiratory irritation, coughing, headache, dizziness, dullness, nausea, shortness of breath and vomiting. High concentrations may cause central nervous system depression, narcosis and unconsciousness. May cause kidney, liver and lung damage. Skin: May cause irritation with redness, itching and pain. Methyl ethyl ketone and cyclohexanone may be absorbed through the skin causing effects similar to those listed under inhalation. Eye: Vapors may cause irritation. Direct contact may cause irritation with redness, stinging and tearing of the eyes. May cause eye damage. Ingestion: Swallowing may cause abdominal pain, nausea, vomiting and diarrhea. Aspiration during swallowing or vomiting can cause chemical pneumonia and lung damage. May cause kidney and liver • damage. Chronic Prolonged or repeated overexposure cause dermatitis and damage Toxicity: to the kidney, liver, lungs and central nervous system. Continued... Page 4 of 6 TFP1992 Toxicity Data: Cyclohexanone: Oral rat LD50: 1,620 mg/kg • Inhalation rat LC50: 8,000 ppm/4 hours Skin rabbit LD50: 1 mL/kg Tetrahydrofuran: Oral rat LD50: 1,650 mg/kg Inhalation rat LC50: 21,000 ppm/3 hours Methyl Ethyl Ketone: Oral rat LD50: 2,737 mg/kg Inhalation rat LC50: 23,500 mg/m3/8 hours Skin rabbit LD50: 6,480 mg/kg Sensitization: None of the components are known to cause sensitization. Carcinogenicity: None of the components are listed as a carcinogen or suspect carcinogen by NTP, IARC or OSHA. The National Toxicology Program has reported that exposure of mice and rats to tetrahydrofuran (THF) vapor levels up to 1800 ppm 6 hr/day, 5 days/week for their lifetime caused an increased incidence of kidney tumors in male rats and liver tumors in female mice. The significance of these findings for human health is unclear at this time, and may be related to "species specific" effects. Elevated incidences of tumors in humans have not been reported for THF. ACGIH has classified cyclohexanone (CYH) and tetrahydrofuran as "A3," Confirmed Animal Carcinogens with Unknown Relevance to Humans. Mutagenicity: Cyclohexanone has been positive in bacterial and mammalian assays. Methyl ethyl ketone and tetrahydrofuran are generally thought not to be mutagenic. Reproductive Methyl ethyl ketone and cyclohexanone have been shown to cause Toxicity: embryofetal toxicity and birth defects in laboratory animals. Tetrahydrofuran has been found to cause adverse developmental effects only when exposure levels cause other toxic effects to the mother. Medical Persons with pre-existing skin, lung, kidney or liver disorders Conditions may be at increased risk from exposure to this product. Aggravated By Exposure: SECTION 12 ECOLOGICAL INFORMATION • This product is not expected to be toxic to aquatic organisms. Cyclohexanone: 96 hour LC50 values for fish is over 100 mg/l. Tetrahydrofuran: 96 hour LC50 fathead minnow: 2160 mg/L. 5 Methyl Ethyl Ketone: 96 hour LC50 for fish is greater than 100 mg/L. VOC This product emits VOC's (volatile organic compounds) in its use. Information: Make sure that use of this product complies with local VOC emission regulations, where they exist. VOC Level: 490 g/1 per SCAQMD Test Method 316A. SECTION 13 DISPOSAL CONSIDERATIONS Waste Disposal: Dispose in accordance with current local, state and federal regulations. RCRA Hazardous Waste Number: U057, U159, U213 EPA Hazardous Waste ID Number: D001, D035, F003, F005 EPA Hazard Waste Class: Ignitable Waste. Toxic Waste (Methyl Ethyl Ketone content) SECTION 14 TRANSPORT INFORMATION DOT Less than 1 Liter (0.3 gal) Greater than 1 Liter (0.3 gal) Proper Shipping Name: Consumer Commodity Adhesives Hazard Class/Packing Group: ORM-D 3, PGII UN/NA Number: None UN1133 Hazard Labels: None Flammable Liquid IMDG Proper Shipping Name: Adhesives Adhesives Hazard Class/Packing Group: 3, II 3, II UN Number: UN1133 UN1133 Label: None (Limited Quantities Class 3 (Flammable are excepted Liquid) from labeling) 2004 North American Emergency Response Guidebook Number: 127 or 128 4111 TFP1992 Page 5 of 6 • SECTION 15 REGULATORY INFORMATION Hazard Category for Section Acute Health, Chronic Health, Flammable 311/312: Section 302 Extremely This product does not contain chemicals regulated Hazardous Substances (TPQ): under SARA Section 302. Section 313 Toxic Chemicals: This product contains the following chemicals subject to SARA Title III Section 313 Reporting requirements: Chemical CAS # % by wt. Methyl Ethyl Ketone 78-93-3 5 - 15% CERCLA 103 Reportable Spills of this product over the RQ (reportable Quantity: quantity) must be reported to the National Response Center. The RQ for the product, based on the RQ for Tetrahydrofuran (45% maximum) of 1,000 lbs, is 2,222 lbs. Many states have more stringent release reporting requirements. Report spills required under federal, state and local regulations. California Proposition 65: This product contains trace amounts of chemicals known to the State of to cause cancer. Under normal Use conditions, exposure to these chemicals at levels above the State of California "No Significant Risk Level" (NSRL) are unlikely. Oatey strongly encourages the use of proper personal protective equipment (PPE) and ventilation guidelines noted in Section 8 to minimize exposure to these chemicals. TSCA Inventory: All of the components of this product are listed on the TSCA inventory. Canadian WHIMS Classification: Class B, Division 2; Class D, Division 2, Subdivision B; Class D, Division 2, Subdivision A. This product has been classified in accordance with the hazard criteria of the Controlled Products Regulations (CPR) and the MSDS contains all the • information required by the CPR. SECTION 16 OTHER INFORMATION NFPA and HMIS: NFPA Hazard Signal: Health: 2 Flammability: 3 Reactivity: 1 Special: None HMIS Hazard Signal: Health: 2* Flammability: 3 Reactivity: 1 PPE: H Disclaimer: The information herein has been compiled from sources believed to be reliable, up- to-date, and is accurate to the best of our knowledge. However, Oatey cannot give any guarantees regarding information from other sources, and expressly does not make warranties, nor assumes any liability for its use. Page 6 of 6 TFP1992 • • • 0 2008 TYCO FIRE&BUILDING PRODUCTS,451 North Cannon Avenue,Lansdale Pennsylvania 19446 • Fire Protection Hangers and Seismic Bracing Pipe Hangers Fig. 200 - "Trimline" Adjustable Band Hanger (Cooper B-line Fig. B317ONF) ®TOLCO illFig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (Cooper B-Line Fig. B317ONFF) c UL us Fig. (Cooper 200C - "Trimline" Adjustable Band Hanger with Plastic Coated B-Line Fig. B317ONFC) LISTED Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm)thru 8"(200mm)pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: • (1/2"(15mm)thru 2"(50mm)) Flared edges ease installation for all pipe �! types and protect CPVC plastic pipe from abrasion.Captured designii keeps adjusting nut from separating with hanger. Hanger is easily 1 B installed around pipe. For hanger with non-captured nut order Fig. 200S. a • (21/2"(65mm)thru 8"(200mm))Spring tension on nut holds it securely in hanger before installation.Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2"(15mm)thru 8" (20omm)) _ `' �� in the USA(UL)and Canada(cUL)for steel and CPVC plastic pipe and i Fig.200-1/2.200-3/4 FactoryMutual Engineering Approved(FM) 3/4"(20mm)thru 8" (200mm)). Fig.ior-,,,,it to 208-2 Fig.2g0-2V2 to 200-8 9� 9 PP ( Conforms to Federal Specifications WW-H-171 E&A-A-1192A,Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, , ,, Type 10. Maximum Temperature: 650°F(343°C) Finish: Pre-Galvanized. Stainless Steel '-1 materials will be supplied with(2)hex nuts F= fi? in place of a knurl nut. Order By: Figure number and pipe size 11 Designed to meet or exceed requirements of FM DS 2-0. ., Fig.200 _. &L1_ Fig.200C Fig.200F Pipe Size Rod Size A B Approx.Wt./100 Part No. in. (mm) in. (mm) in. (mm) to (kg) 200-1/2 1/2" (15) 3/8"-16 31/8" i (79.4) 25/8" (66.7) 11 (5.0) 200-3/4 3/4" (20) 3/8"-16 31/8" (79.4) 21/2" (63.5) 11 I (5.0) 200-1 1 (25) 3/8"-16 33/s" (85.7) 25/8" (66,7) 12 I (5.5) t 200-11/4 11/4" (32) 3/8"-16 33/4" (94.0) 27/8" (73.0) 13 (5.9) 200-11/2 11/2" (40) 3/8"-16 37/8" (98.4) 27/a" (73.0) 14 (6.4) 200-2 2" (50) 3/8"-16 41/2" ! (114.3) 3" (76.3) 15 (6.9) -, 200-2 1/2 2/2" 1 1 (65) 3/8"-16 5518" (142.9) 41/8" (1047) 27 (12.3) 200-3 3' (75) 3/8%16 57/8" i (149.1) 4" (101.6) 29 (13.3) Fig.200S 200-31/2 31/2" (90) 3/8"-16 73/8" (187.3) 51/4 (133.3) - 34 (15.6) 200-4 4" (100) 3/8%16 73/8" (187.3) 5" (127.0) 35 (16.0) 200-5 5" (125) 1/2"-13 91/3" I (231.8) 61/4" (158.7) 66 (30.2) • 200-6 6" (150) 8" (200) 1/2"-13 101/8" (257.2) 63/4" (171.4) 73 (33.4) 200-8 1/2"-13 131/8" (333.4) 83/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. 20 01. COOPER B-Line Threaded Accessories Fig. B3205 - Threaded Rod (right-hand threads - both ends) (TOLCo Fig. 103) ®TOLCO • Fig. B3205L - Threaded Rod (right& left hand threads) TLSize Range: 3/8"-16 thru 3"-4 rod Specify Length 11y Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. Rod is threaded on both ends with right hand threads of the length shown.Also TL . lie available with left and right hand threads-specify Fig. B3205L when ordering. .\ A Maximum Temperature: 750°F(399°C) Thread Size Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number, rod size, length and finish Standard Design Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) B3205-3/8 x'L' 3/8"-16 21/2" (63.5) 730 (3.25) 572 (2.54) B3205-1/2 x'L' 1/2"-13 21J2" ! (63.5) 1350 (6.00) 1057 (4.70) 133205-5/8x'L' 5/a"-11 21✓2" (63.5) 2160 (9.61) 1692 (7.52) B3205-3/4 x'L' 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) B3205-7/a x'L' 7/8"-9 31/2" (88.9) 4480 (19.93) 3508 i (15.60) • For larger sizes consult full line pipe hanger catalog. —I S Fig. ATR - All Threaded Rod (TOLCo Fig.99&Fig. 100) p Size Range: 3/8"-16 thru 11/2"-6 rod in 10' (3.05m)lengths el cl Material: Steel Q Maximum Temperature: 750°F(399°C) y Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number, rod size, length and finish Note: Fig. 99 is cut to length all threaded rod. Fig. 100 is full length. Part No. Threads Recommended Load Approx.Wt./100 Ft. &Size Per Inch Lbs. (kN) Lbs. (kg) ATR 1/4"x`L' 20 240 (1.07) 12 (5.44) ATR 3/6"x`L' 16 730 (3.24) 29 (13.15) ...°-. ATR 1/2"x`L' 13 1350 (6.00) 53 (24.04) f. ATR 5/8"x'L' 11 2160 (9.60) 89 l (40.37) ATR 3/4"x'L' 10 3230 (14.37) 123 ' (55.79) • ATR 7/e7 x'L' 9 4480 (19.93) 170 (77.11) For larger sizes consult full line pipe hanger catalog. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line Beam Clamps Fig. 65 - Reversible Steel C-Type Beam Clamp 3/4" (19.0mm) Throat Opening • Fig. 65XT - Reversible Steel C-Type Beam Clamp 3/4" (19.0mm) Throat Opening (bottom of page) Size Range: Component of State of Fig.65 - 1/2"-13 rod sizes,and 5/a"-11 rod sizes 4 V California OSHPD Approved Fig.65XT - 3/8"-16 rod size (see below) ", Seismic Restraints System Material: Steel with hardened cup point set screw and jam nut Function: Recommended for hanging from steel beam where flange thickness does C Ul us not exceed 3/4"(19.0mm). LISTED Features: All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of beam. (Beveled lip B allows hanging from top flange where clearance is limited.) May be installed with set B screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp.Open design permits inspection of oak thread engagement. 4.,Tori Ec Approvals: Underwriters Laboratories Listed in the USA(UL)and Canada(cUL).Exceeds requirements of the National Fire Protection Association(NFPA), pamphlet 13, 4� � 3/e"-16 rod will support 1/2"(15mm)thru 4"(10omm)pipe F �� ' 1/2"-13 rod will support 1/2"(15mm)thru 8"(2oomm)pipe , A %f Included in the Seismic Restraints Catalog approved by the State of California \w Office of Statewide Health Planning and Development (OSHPD). For additional load `/ spacing and placement information relating OSHPD projects, please refer to the Seismic Restraint System Guidelines. Set Screw and Locknut Included Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number and finish Fig.65 Patent#4,570,885 ., • • �... r Part Rod Size B C D E . No. A in. (mm) n. (mm) in. (mm) in. (mm) 65-1/2 1/2"-13 11/2" (38.1) 3/4" ; (19.0) (25.4) 9/16" (14.3) 65.5/8 5/8"-11 11/2" (38.1) 3/4" (19.0) (25.4) 9/16" , (14.3) 4., A' Part F Mac Rec. Load * Approx. Wt./100 j.. No- in. (mm) in. (mm) in. (mm) 65-1/2 11/4" 31.7( ) 1130 (5.02) 55 (24.9) 65-5/8 11/4" (31.7) 1130 (5.02) 55 (24.9) ' Maximum loads for clamp with set screw in up or down position. Fig. 65XT-3/8 - Beam Clamp can 41/: (25.4) Feature: Extruded holes allow for more thread LISTED ° ° hi 0101P'engagement of threaded rod and set screw. "" 19/76" (39.� Weight: Approx.Wt./100 28.0 Lbs. (12.7kg) b� Design Load: 730 Lbs(3.25kN) ) 3/4. / Finish: Plain or Electro-Galvanized - (19•0) Order By: Figure number and finish #; Vol, Approvals: Underwriters Laboratories Listed ��I and FM Approved for uo to 4"(toomm)pipe. . - TX r Set Screw and ' Locknut Included 13%a' Izz.z) (34.9) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. 31 PO COOPER B-Line Beam Clamps Fig. 69 - Beam Clamp Retaining Strap (Cooper B-Line B3367) Size Range: 3/e"-16 thru 3/4"-10 rod Q Component of State of • 4"(101,6mm>thru 16"(406.4mm)lengths CO O California OSHPD Approved Seismic Restraints System Note: longer lengths are available consult factory LIMO Material: Pre-Galvanized Steel Function: To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of NFPA 13. 411:41111Nop Important Note: Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly.Therefore a locking mechanism of some kind,such as a hex nut or the beveled locking slot of the Fig.69R will provide a more secure reliable installation. Approvals: Underwriters Laboratories Listed in the USA(UL) and Canada(cUL). Approved for use with any listed beam clamp. Included in the Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development(OSHPD). For additional load spacing and placement information relating OSHPD projects, please refer to the Seismic Restraint System Guidelines. ` ,µ Finish: Pre-Galvanized Order By: Figure number, length(L), and finish. Note: Minimum return on strap is 1"(25.4mm) Hole Dia. D For Use With Length Part No. in. (mm) 69-3/s L 7hs„ B3033-3/t,B3034-3/8,B3031-3/a, __ (30.1) Specify 65-3/8,65XT-3/a,66-3/8 a iI 69-1/2-L 9/16" (30.1) B3033-1/2,B3034-1/2,65-1/2,66-1/2 Specify 69-5/8-L 11/16" (50.8) B3033-5/8,65-5/a,66-5/8 Specify 69-3/4-L 13h6" (63.5) 83033-3/4 Specify .. sir • All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line Upper Attachments Fig. 75-Swivel Attachment ®TDLCO • Size Range: — 3/8"-16 Rod Attachment C®us LISTED Material: Steel Function: Three recommended applications for this product: • May be used as a Branch Line Restraint for structural attachment to 410 anchor bolt, beam clamp, etc. • May be used in a pitched or requirements of NFPA 13(2010)sloped.1 roof application,to meet Approvals: Underwriters Laboratories Listed in the USA(UL)and `� Canada(cUL)to support up to 4" (100mm)pipe. ` Finish: Electro-Galvanized 11 +JIr� Weight: Approx. Wt./100 13.3 Lbs. (6.0kg) �``t-4 t Order By: Figure number Patent:#7,887,248 , '" r Fig.78 All Steel aCeiling Plate `• '°. 0 Fig.75 Swivel Attachment 3 m Fig.200 All Threaded Rod a, "Trimline" 0 Adjustable CI Band Hanger jPPOt/ 4 Fig.25 Surge Restrainer May be used as a structural attachment component of a branch line restraint Fig.65XT Reversible _ Beam Clamp W-Beam _`:'•''- Fig.75 Swivel Attachment All Threaded Rod May be used with a pitched roof application,to meet requirements of NFPA 13(2010)Sec.9.1.2.5. • All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. 80 I/ COOPER B-Line 1 • Speedy Products, Inc. 2472 East Seventh Avenue North St. Paul, MN 55109 Values Speedy places values first, as the foundation for all business dealings— promoting honesty, open straightforward communication and mutual respect. • Vision Recognized for original ideas and extraordinary product development, we continue to provide time saving solutions for today global construction needs. Mission Dedicated to unparalleled customer service, superior quality and innovative products we create ever-increasing profitability and prosperity for our customers,partners and employees. The Speedy Team remains uncompromisingly committed to you! • Catalog 2001 Versa"; Page 1 Special Notes Engineering Note In 1996 the screws listed by UL were tested in plate steel that measured.188 and.118.Subsequent testing was done for purlin applic tions on May 5, 1997 using.037 or 20 gauge steel. Metric Sizes Sammy Super ScrewsTM and SidewindersTM are available to hang metric threaded rod(6mm,8mm,and 10mm)or bolt stock. Sammy Nut Drivers Special nut drivers were designed to be used with the Sammy Super ScrewTM anchoring system.When the appropriate nut drivers are used for installation the driver spins free on the screw after installation is complete and eliminates the expected wrist snap,reduces over-torque,and prevents screw failure.See installation procedures on pages 18 and 19. Stainless Steel Screws For standard stainless steel inventory,refer to pages 10 and 11.Additional screws can be made with mild screws and stainless steel heads.Please call 888.773.0001 for additional information. Steel Screws Due to variations in hardness of certain metals,it should be noted our self-drilling screws for steel will experience different drill rates. 500-1500 RPM drill speed should be tried.Resulting drill chips should not be blue in color.Residual drill chips that are blue in color indicate the drill RPM level is too high. Vibratory Environments For attaching or anchoring in high vibratory environments,special care should be taken not just for building attachments but also fo the hangers or assemblies being supported.Consult local code authorities for accepted anchoring devices. TJI Joist I Truss Truss manufacturers vary installation recommendations for TJI joist.Sidewinders SWG 20 and SWG 25-380 can be installed into the top cord of a truss.Sammy GST 20 can be installed into the center of the lower cord of a TJI.Penetration of the upright center web is permitted by some joist manufacturers. Pre-drilling may be required by joist manufacturers.If so,pre-drill pilot 1/8"smaller than root diameter of fastener.Consult table below: Model Root Diameter Hole Size GST 20 0.182 1/8" GST 25-380 0.280 7/32" SWG20 0.182 1/8" SWG25-380 0.280 7/32" To increase efficiency of the installation process,sleeve tools,bit receivers and wood bits are available for pre-drilling. NFPA Requirements Sammy screws noted with NFPA under"Approvals"column meet NFPA requirements.Check with local Authority Having Jurisdiction to confirm application and usage. UL Listings / FM Approvals • UL and FM reports are available at www.SammySuperScrew.com CAD Drawings Cad Drawings are available and can be downloaded at www.SammySuperScrew.com Page 3 STEEL - Sam mysav ie"S Self-Drilling • Self-tapping _Ai_ STEEL• 1/4"Rod(Vertical Mount) l Use#14 Nut Driver(Item#100) Screw Weight Item# Model Box Qty (per 100) Case Qty Description 50 DSTR 100 1/4-20x1 100 625 1000 51 DST 100 1/4-14x1 100 5.25 1000 �� 52 DST 150 1/4-14x1 1/2 100 5.50 1000 53 DST 200 1/4-14x2 100 6.00 1000 54 DST25O 1/4-14x2 1/2 100 6.75 1000 #14 55 DST3O0 1/4-14x3 100 7.25 1000 (Item#100-black) 1 .. Sammys114",36"rod 56 TFat 500 12-24x1 1/2 100 5.50 1000 STEEL•3/8" Rod(Vertical Mount) Use#14 Nut Driver(Item#100) Approvals Item Model Screw FM Test UL Test UUFM Mininmm Maximum Actual Pullout Bit Description Load,lb. Load lb. Pipe Size Thickness Thickness ut•FM•NFPA 29 DSTR 1 1/2" 12-24x1 1/2 1475# 1500# 3/4-4 1/4" 1/2" 1510#/1/4 I UL•FM•NPPA 30 DSTR 1" 1/4-20x1 1475# I500# 3/4-4 .036"-20 ga 1/4" 1510#/20 ga I UL•NFPA 31 DSTR516 5/16-18x1 1/4 1500# 4 .036"-20ga 1/4" 2200#/20ga I NFPA 32 DST 10 1/4-14x1 Note:Screw drmn eter/design/ .036"-20 ga 1/4" 446#/20 ga I NFPA 33 DSTIS 1/4-14x1 1/2 -perfttrwe eefortheDSTIO(I" 1/4" 970#/16 ga I NFPA 34 DST20 1/4-14x2 length)through the DST30(3" 1/4" I NFPA 35 DST 25 1/4-14,2 1/2 length)are constant Only the 1/4" I NFPA 36 DST 30 1/4-14x3 lengths w"r' 1/4" I UL•NFPA 37 DST 516 5/16-18x1 1/4 1500a 4 .188"-3/16" 1/4" 1500#/3/16" I •FM•NFPA 38 TF7C50 12-24x1 1/2 1475# 1/4" 1/2" 3125#/1/4" 1 STEEL• 1/2" Rod(Vertical Mount) Use#14SW Nut Driver(Item#101) Item# Model Screw Minimum Maximum Actual Pullout Box Qty Weight Case Qty Description Thickness Thickness (per 100) 601 DST 2.0 1/4-14x2 I88"-3/16" 1/4" 50 6.75 500 1113 DST2.5 1/4-14x2 1/2 .188"-3/16" 1/4" 50 7.25 500 422 DSTR 1.0 1/4-20x1 .036"-20 ga 1/4" 1510#/20 ga 50 500.00 7 28 DSTR5.16 5/16-18x1 1/4 .036"-20 ga 1/4" 2220#/20 ga 50 8.00 500 #14SW (Item#101-red) 443 DST5.16 5/16-18x11/4 .188"-3/16" 1/4" 1500+#/3/16" 50 6.75 500 Sidewinders& 05 TUC5.0 12-24x1 1/2 .25"-1/4" 1/2" 3125#/1/4" 50 6.0 L0 500 Sammys ll2"rod tq - P[ MIN 1 II a Ill 2 2` • For fastening/anchoring in high vibratory environments, consult local code authorities for accepted anchoring devices Page 6 UL Listings and CAD Drawings are available at www.SammySuperScrew.com Note.Screwsmust be tnnutted wihapprvpdate nut drives torompty with warranty STEEL —Sidewinders YIN';: Self-Drilling • Self-tapping r i of J #14SW I. (Item#101-red) Sidewinders& Sammys 1/2"rod _ STEEL• 1/4" Rod(Horizontal Mount) -I. Use#14SW Nut Driver(Item#101) Item# Model Screw Minimum Maximum Actual BoxQty Weight Case Qty Description Thickness Thickness Shear/Pullout (Per l00) i.' 2003 SWD 100 1/4-14x1 .066'-l6 ga 1/4" 1477#/16 ga 100 6.00 1000 407 SWD 200 1/4-14x2 .066"-16 ga 1/4" 1477#/16 ga 100 6.50 1000 steel screw shown with retainer ma 206 'SWDR 100 1/4-20 .036"-20 ga I/4" 1900#!20 ga 100 6.00 1000 SWDR screws include retainer nut STEEL•3/8" Rod(Horizontal Mount) Use#145W Nut Driver(Item#101) Approval Item# Model Screw ULTest UL/FM Minimum Maximum Actual goxQty Weigh Description Load lb. Pipe Size Thickness Thickness Shear/Pullout (per 10C NFPA 39 SWD 10 1/4-14x1 .066"-16 ga 1/4" 1477#/16 ga 100 6.00 NFPA 40 SVVD 15 1/4-14x11/2 Note:Screw diameten'design/perfornrancefor SWDl11(1`tlength) 100 7.50 NFPA 41 SWD 20 1/4-14x2 through SWD 20(20length)are constant Only the lengths vany. 100 6.50 NFPA 42 SWD 516 5/16-18x1 1/4 100 ' 7.00 ❑L-NFPA 46 SWDR 11/2" 1/4-20x1 1/2 1500# 4 25"-1/4" 1/2" 2375k/,25"-1/4" 100 7.25 UL•NFPA 43 SWDR 1" 1/4-20x1 1500k 4 036"-20 ga 1/4" 1900#/20 ga 100 7.00 UL•NFPA 44 SWDR 516 5/16-18x1 1/4 15004 4 .036"-20 ga 114" 2480#/20 ga 100 8.25 NFPA 45 SWT 15 12-24x1 1/2 .25'-ua^ 1/2" 100 6.25 • PERFORMANCE DATA FOR STEEL SHEET STEEL GAUGES Gauge No. 1/4 3/16 12 14 16 18 20 22 24 26 �a1 �, 10 IN Decimal Equivalent .25 .188 .105" .075" .060" .048" .036" .030" .024" .018" Ultimate Pullout Values -Sammys (average lbs.ultimate) Fastener Steel Gauge -.,, Model Dia. Pt. 20 18 16 14 12 3/16 1/4 k =_. DST 1/4 #3 446# 613# 970# 1145# 1544# 3190# )s 11 DST 516 5/16 #3 457# 568# 1209# 1712# 2422# 3716# )•....If TIX50 #12 #5 487# 699# 913# 1527# 3270# 3593# DSTR 1 1/2" #12 #5 3270# 3593# DSTR 1" 1/4 #3 1510# DSTR516 5/16 #3 2200# Aluminum Curtain Wall Extrusion Ultimate Shear/ Pullout Values- Sidewinders Ultimate Pullout Values (average lbs.ultimate) (average lbs.ultimate) Fastener Steel Gauge Fastener Thickness Model Dia. Pt. 20 18 16 14 12 3/16 1/4 Model Dia. Pt. .114 .092 .365 .132 SWD 1/4 #3 1477# DST 10 1/4 #3 1265# 2750# SWDR 11/2" #12 #5 2375# SWD10 1/4 #3 1120# 1420# • SWDR 1" 1/4 #3 1900# 1900# SWDR 516 5/16 #3 2480# 2480# For fastening/anchoring in high vibratory environments, consult local code authorities for accepted anchoring devices Note:Screws must be installed with appropriate nut driver to comply-with warranty Page 7 CONCRETE — Sammyslit . III CONCRETE • 1/4" Rod(Vertical Mount) _kik_ Use#l4 Nut Driver(Item#100) Item# Model Shk Lgth Shk Dia Box Qty (per 100)Weight . 3 Case Qty �( r , ; i 64 CST 200 11/2 5/16 100 6.75 1000 r6ri°( - CONCRETE• 3/81s Rod(Vertical Mount) ) 14 Use#14 Nut Driver(Item#100) (Item#o0-black) Sammys 1l4",3/8"rod Item# Model Shk Lgth Shk Dia Box Qty Weight Case Qty (per 100) 61 CST 20 1 1/2 5/16 100 6.25 1000 : , CONCRETE• 1/2" Rod(Vertical Mount) Use#14SW Nut Driver(Item#101) Approvals Item# Model Shk Lgth Shk Dia Box Qty Weight Case Qty (per 100) #14SW (item#101-ree) NI PA 66 CST2 11/2 5/16 50 7.00 500 Sidewinders& Sammys 112"rod c. p l'' per' a� G OkeC1F�S D. t rya9aFC .1 }A. t i • 7 " 9,}b 01'1 O , o;i> sIcxkoma7. ="Yv qi. DD ,'pGs6.. 1 . 1 CONCRETE — Sidewinders 7 CONCRETE• 3/8" Rod(Horizontal Mount) Use#14SW Nut Driver(Item #101111 i , Approvals Item# Model Shk Lgth Shk Dia Box Qty Case Qty Weight (per 100) �g NFFA 65 SWC 20 11/2 5/16 100 1000 7.5 M t ie3 I7x #14SW s 4p°r Da.^ (Item#101-re d) ♦ -6 f:,% Sidewinders& {' • yC . q,,, _ Sammys l/2"rod ' S '.A7..k"o'iFa • ." a, o- <a`.""r „xA`,1^rt CONCRETE• 1/4" Rod(Horizontal Mount) , )a ,nl ,, a.q=tVi" r° Use#14SWNut Driver(Item#l01) , F_, l' aRoi,� 11, iii ' ry b Weight PAL ,r $ Item# Model Shk Lgth Shk Dia Box Qty (per 100) Case Qty ` 1900 SWC 200 1 1/2 5/16 100 7.5 1000 For fastening/anchoring in high vibratory environments, consult local code authorities for accepted anchoring devices Page 8 UL Listings and CAD are Drawings available at www.SammySuperScrew.com Note.Screws roust be installed with appropriate nut driver to comply with warranty STAINLESS STEEL - STEEL For use in corrosive environments (i.e. food, marine, chemical) 303 stainless caps; 410 stainless heat-treated drill screw • #14 (Item#100-black) Sammys tl4",318"rod STEEL• 1/4" Rod(Vertical Mount) Use#14 Nut Driver(Item#100) Item# Model Screw Minimum Maximum Actual Box Qty Weight Case Qty Description Thickness Thickness Shear/Pullout (per 100) Sammys 4004 DST 100-SS 1/4-14x1 .036"-20 ga 1/4" 446#/20 ga 50 5.00 500 4116 DST 150-SS 1/4-14x1 1/2 .036"-20 ga 1l4" 970#/16 ga 50 5.00 500 STEEL•3/8" Rod(Vertical Mount) Use#14 Nut Driver(Item#100) Approvals Item# Model Screw Minimum Maximum Actual DoxQty Weight Case Qty Description Thickness Thickness Shear/Pullout (per 100) NPPA 1152 DST 10-SS 114-14x1 036"-20 ga 1/4" 446#/20 ga 50 5.00 500 NPPA 1154 DST 15-SS 1/4-14x1 1/2 .036"-20 ga 1/4" 970#/16 ga 50 5.00 500 f S --A1--_ d ® I 3t,•.. k • . I. heh Sidewinders STEEL• 1/4"Rod(Horizontal Mount) Use#14SW Nut Driver(Item#101) Approvals Item# Model Screw Nfinimum Maximum Actual PkgQty Weight Case Qty #14SW Description Thickness Thickness Shear/Pullout (per 100) (item#101-red) NFPA 4119 SWD 100-SS 1/4-14x1 066"-16ga 1i4" 1477#/16ga 50 6.25 500 Sidewinders& Sammys 1/2"rod STEEL•3/8Mount)" Rod Horizontal ■e w ve ~ Use#14SW Nut Drir(Item#101) .i a.. Approvals Item# Model Screw Minimum Maximum Actual Pkg Qty Weight Case Qty Description Thickness Thickness Shear/Pullout (per 100) NPPA 49 SWD 10-SS 1/4-14x1 .066"-16 ga 3/16" 14776/16 ga 50 6.25 500 ir-,, NFPA 03 SWD 15-SS 1/4-14x1 1/2 3/16" 50 6.25 500 ,xl , 1i • 1 For fastening/anchoring in high vibratory environments, consult local code authorities for accepted anchoring devices r .. .-, •x Stainless caps are available in metric size by special order Note:Screwsmust be installed with appropriate nut driver to comply with warranty Page 11 INSTALLATION INSTRUCTIONS SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin off feature which provides a fast and safe installation each time. When the face of the driver comes in contact with the material you are installing into, continue drill- g until nut driver spins free. Installation is then complete.Warranty requires the use of appropriate nut driver for 0 installations MAXIMUM DEFLECTION ALLOWED UMOEFI wlNWNIT . 'i IMPORTANT INSTALLATION PROCEDURES:Sammy Super Screws TM (vertical mount)have 9; x been tested for straight pullout.The Sidewinders TM (horizontal mount)have been tested for shear. ` Installing any of the units and then deflecting the receiver head more than 15 degrees could result - ! , e in weakening of the unit or separation(see chart for deflection guide).Any deflecting beyond 15 .` degrees nullifies the warranty.All units are to be installed with the appropriate nut driver—#14, fl ( #14SW,or#12 nut driver,which have a built-in automatic release mechanism toprevent over- f. tightening. If other tools are used for installation warranty is void. YY I Important Vertical Installation Note:Warranty requires the use of appropriate nut driver for installations:Model#14 for installing the Sammys for 1/4"rod and 3/8"rod; Model#14SW for Sammys for 1/2"rod;and Model#12 for installing Juniors. Model#14-(Black)-Sammys for 114"and 3/8"rod Model#14SW(Red)-Sammys for 1/2"rod Model#12-(Blue)-All Juniors i i i Eye protection should be worn at all times when installing this product. Model#14 Model#14SW Mode/#12 (hem#100) (hem#101) (Item#102) Vertical Installation for Steel or Wood—Model DST, DSTR, TEK 50, GST, JRS, JRW,JEW,JES DST-Self drilling& tapping into steel up to 3/16"thick;DSTR-Self drilling&self tapping into steel up to 3116"thickness •ith retainer nut; TEK 50-Self drilling&self tapping in steel up to 1/2"thick; GST-Self drilling&self tapping into wooden structural member. Insert the appropriate nut driver(see Vertical Installation Note above)into a 3/8"or 1/2"portable drill. Insert screw into nut driver. Drill should be in a vertical position. Push the face of the nut driver tight to the member.When the nut driver spins freely on the screw,stop drill and remove.The screw is now ready to receive 1/4", 3/8", 1/2"or metric all thread rod, bolt stock;or 5/32 wire for Junior eyelet screws. See figures 1-4 for installation.Note for DSTR: When installing DSTR follow the above ('}[ ...., instructions, then add retainer nut and torque to 20 foot lbs. for maximum l pullout in purlin steel. `g ' 7 i Vertical Installation for Concrete—Model CST, JRC,JEC Self tapping into concrete. Note:Use a 1200 maximum RPM drill for installation. Using a SDS 250 or SDS 316(Jr.) carbide tip bit;or a HEX RECEIVER with a #250 or#316(Jr.)carbide tip bit, pre-drill the concrete member to a depth of 2" with an electric impact/drill set on impact mode.After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill),and insert the appropriate nut driver into the opposite end (see Vertical Installation Note above). Insert the concrete screw into the nut driver. Now you are ready to install the screw into the concrete member. Place tip of screw into the pre-drilled hole,turn impact/drill unit to drill mode and begin inser- tion.When the nut driver spins free on the screw, installation is complete. Stop and "" "' remove drill.The concrete screw is ready to receive 1/4",3/8", 1/2", or metric all thread A A rod or bolt stock. See figures 5-10 for installation. NOTE:Do not install concrete fig 5 fig.6 fig 7 1 screws while the drill unit is in impact mode—doing so will destroy the pullout factor of the screw. "...... '' 11,• fig.8 9g.9 _r fig.10 Page 18 Vertical Installation for Toggle—Model SST, JRT, JET For use in sheetrock ceilings, metal lath &plaster, metal liners, thin wood, ceiling panels etc. The SST is a light duty fastener and should be used with consideration. Pre-drill a 5/8"hole with a regular drill bit or hole saw. Insert appropriate nut driver(model#14 for SST or#12 for Junior toggles) into light duty drill or screw gun.With wing nut and washer on bolt,inse wing nut through surface and begin installation.When the nut driver spins free on the screw,stop the drill and remove.Th screw is now ready to receive 1/4", 3/8"or metric all thread rod or bolt stock or 5/32 wire for Junior eyelet screws. Important Horizontal Installation Note:Warranty requires the use of appropriate nut driver for installations: Model#14SW(Red)-Sidewinders Eye protection should be worn at all times when installing this product. Horizontal Installation for Steel or Wood — Model SWD, SWDR, SWT, SWG Mode/#14SW SWD-Drills & taps through 3/16"metal;SWDR -Drills &taps through 3/16"metal, accepts retainer nut; SWT-(Ates ° taps through 1/2"metal;SWG-Drills&taps into wooden structures. Insert the#14 SW nut driver in the drill unit. Insert the screw into the nut driver. With drill unit in a horizontal position and at a right angle to the structural member begin installation.When the nut driver spins free on the screw,stop the drill and remove.The unit is now ready to receive 1/4", 3/8"or metric all thread rod or bolt stock. Be sure rod is threaded completely through unit head. See figures 11-14 for installation. Note for SWDR:When installing SWDR follow the above instruc- tions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in _:, ; - purlin steel. t giro-„ ern .n n9.It l Horizontal Installation for Concrete—Model SWC Self tapping into concrete. Note:Use a 1200 maximum RPM drill for installation. Using a SDS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, predrill the concrete member to a depth of 2"with an impact/drill set on impact mode.After pre-drilling has been completed, install the SLEEVE TOOL over the bit(the bit should remain in the drill),and insert the#14SW nut driver into the opposite end. Install the SWC screw into the nut driver. Now you are ready to install tf• screw into the concrete member. Place tip of screw into the pre-drilled hole,turn z: - ::. impact/drill unit to drill mode and begin insertion.When the nut driver spins free on the „r SWC screw, installation is complete. Stop and remove drill. The SWC screw is ready fig.15 •_fig.16 fig.17 " 3/8", 1/2", or metric all thread rod or bolt stock. See figures 15-20 for to receive 1/4 , g installation. NOTE:Do not install concrete screws while the drill unit is in impact `•r' ' ' ' "` __::`: mode—doing so will destroy the pullout factor of the fastener. ;,, j^ 9g.18 _fig.19 fig 20 Vertical Installation for Junior Nail—Model JRN, JEN Install the Junior nail-type fastener with hammer until completely imbedded in wood. Fastener is now ready to receive 1/4"threaded rod or bolt stock for JRN;or 5/32 wire for JEN. Eye protection should be worn at all times when installing this product. WARRANTY/DISCLAIMER OF WARRANTIES SPEEDY PRODUCTS,INC.("Seller")states that there is no warranty,representation or condition of any kind,express or implied,(including no warranty of merchantability or fitness for a particular purpose),except as specified herein,and no such warranty shall be implied by law.Seller warrants that its product shall be in accordance with the specifications set forth in seller's testing data and as stated on the usage and installation instructions.A final determination of the suitability of the material forthe use contemplated by buyer is the sole responsibility of buyer.It is understood and agreed that seller's liability,whether on contract, in tort, under any warranty, in negligence or otherwise, shall not exceed the return of the amount of the purchase price paid by buyer. Under no circumstances shall seller be liable. Page 19 Recommended Safe Load Sammys/Sidewinders Pullouts listed are average actual pullouts and should be used as reference only for calculations of acceptable pullout and shear values.Values are ultimate averages achieved under laboratory conditions and apply to fasteners manufactured by Speedy Products,Inc.only.In the process of doing engineering,design personnel should divide by the recommended safe load average per the industry requirement. NFPA 13 2-6.1—Fire protection fastening requirements:Five times the weight of the water filled pipe plus 250 lbs. Example:Based on 15 ft.of 3"pipe(schedule 40). Additional Pipe, Weight, Length chart-next page Wt of H20(#Igal) x Gal/ft t•..a,e = Wt/ft of H2O 8.34# x .3840 = 3.20# Pipe wtlft prw t + H2O wV1t = Water filled pipe wVft 7.575# + 3.20# = 10.775# Water filled pipe Mitt x Pipe Lgth = Actual wt.per 15 ft 10.775# x 15' = 161.63# Safety Factor x Actual Wt+250# = Safety Load 5 x161.63# +250# = 1058# Steel Screws Due to variations in hardness of certain metals,it should be noted our self-drilling screws for steel will experience different drill rates.500-1500 RPM drill speed should be tried.Resulting drill chips should not be blue in color.Residual drill chips that are blue in color indicate the drill RPM level is too high. NFPA Requirements Sammy screws noted with NFPA under"Approvals"column meet NFPA requirements.Check with local Authority Having Jurisdiction to confirm application and usage. . Page 20 Nominal Pipe Acute!Inside Actual Outside Diameter In Inches Weight Per Foot Pounds Length In Feet Gallons in One 15'Schedule 40 12'Schedule 10 Diaz Master Diameter in Inches Diameter in Inches Diameter in Inches Foot Pounds Containing One Cubic Foot Lineal Foot 3/4 0.824 1.050 1.130 270.030 0.0277 1 1.049 1.315 1.678 166.620 0.0449 410 326 271 1 1/4 1.380 1.660 2.272 96.275 0.0777 430 349 286 1 1/2 1.610 1.900 2.717 70.733 0.1058 520 420 300 2 2.067 2.375 3.652 49.913 0.1743 635 496 317 2 1/2 2.469 2.875 5.793 30.077 0.2487 940 509 397 3 3.068 3.500 7.575 19.479 0.3840 1060 ' 573 492 31/2 3.548 4.000 9.109 14.565 0.5136 4 4.026 4.500 10.790 11.312 0.6613 1475 674 41/2 4.560 5.000 12.536 9.030 , 0.8284 5 5.047 5.563 14.617 7.198 1.0393 6 6.065 6.625 18.974 4.984 1.5008 • • • I SAMMY X-PRESS® Installs into Metal Deck, Purlin, or Tubular Steel 11 SAMMY X-PRESS® - Vertical Application Application Product Features •The Sammy X-Press expands to provide •Less jobsite material needed. direct vertical attachment in: Ili {XP) light gauge steel deck or purlin •No retaining nut required -:�:.Q«..o.... _ (22 ga.-116"). ,:", ... •Provides design flexibility ' • •Installs in seconds with Sammy X-Press It Tool, l'llsaving time&installation costs. •Manufactured in the U S A. •Use in applications where access to the back of the installed fastener is prohibited ie metal roof deck,tubular steel,or va or banter fabric. Wed,avSeaSemn^St-- "'�, Pwww.itwbuildex.corn J Approvals Rod Part Model Description Ultimate UL Test UL Min FM Test FM Min Max Box Case Application Size Number Pullouttlbs) Load(Ibs) Thick Load(Ibs) Thick Thick Qty Qty .....Rn ....... t!4' 8181922 XP 200 Sanvity 1146(22 gat 185(Luminairel D2T .125" 25 125 Metal Deck X-Press 200 250 i Luminaire`, 056' 850(2%'Pipe) .027' 940(2'Pipe) .029' :�, 3l8' 8150922 XP 241 Sammy 1146 22 1851LuminaireJ .027' X-Press20 ( �? 250(Wminaire) ,056' 1475(4'Pipe) atb4' .125' 25 125 Metaifkdk 283(Conduit&Cable) .029' 1503(4'Pipe) 060' .. 3/8' 8153922 XP35 Sammy 1783(169a) 185(Luminaire) .029' 940 (2'Pipe) A29' 125' 25 125 Pullin X-Press 35 250(Lrxninaire) 056' 1475 54'Pipe) ,104' 416(Conduit&Cablet 059' — Pre-Pour Structural Concrete@ 3000 psi Metal Deck TM 8150922 XP 20 Sammy 1146(22 gal 850(25;Pipe) 25 125 (Pre-Pour) X-Press 20 metal Deck Post-Pour Range 11 LWCS 35 PCF OOP) (Post-Pour) Pm-Pour Structural Concrete gg 3000 psi Post-Pow Range If LWCS 35 PCF(lbsr ft') SAMMY X-PRESS SIDEWINDERTM - Horizontal Application Application Product Features I .7. •The Sammy X-Press Sidewinder expands to •Less jobsit material needed. provide horizontal attachment in. ' g -16 ga-3/16-steel-puffin,tubular steel. •No retaining nut required 1 '."'=•1. - •Installs in seconds with Sammy X-Press le Tool, •Provides design flexibility, saving time&installation costs. •Manufactured in the U.S.A. •Use in applications where access to the back of the installed fastener is prohibited;ie metal roof ( P),. ! deck,tubular steel,or vapor barrier fabric. �����s a�111a 19M9, A vela Rod Part Model Des xi tion Ultimate UL Test UL Min FM Test Max Box Case PPS Size Number p Pullout(Ibs) Load Ohs) Thick Load(lba) Thick Qty Qty Application Sidewinder 1250(3Y:'Pipe) 3!e` 8293957 SWXP 35 1798(16ga) 80(Luminaire) .059' 125' 25 125 Pullin X-Frees 95 41& (Conduit 8 Cable) ry ANWX'SG,USD USA N..'F Cw•w For the roost up to date information,vis+t yam iiwbuildex coin 8 mimmilimmiiimm zAme7g1c hi SAMMY X-PRESS SWIVEL" - Swivel Application Application Product Features •The Sammy X-Press Swivel allows you •Less jobsite material needed to hang plumb in extreme roof pitches: ''Ni."/ -89'in z-pudin •No retaining nut required. •45'in metal deck for 12/12 pitch } fQ{t •Provides design flexibility. q •Installs k1 seconds with Sammy X-Press Ite Tool, (SXP} ��I SY Yv saving time&installation costs. •Manufactured in the U.S.A. OR V Nag{Iq "t •Use in applications where access to the back of !tt E"1C'L the installed fastener is prohibited.ie.metal roofivgb' KO� $ deck.tubular steel.or vapor barrier fabric. wwwitwbuildex.com) Approvals Rod Part Model Description Ultimate UL Test UL Min FM Test FM Min Max Box Case Application �.�. Sue Number Pullout(Ibs) Load(Iba) Thick Load(Iba) Thick Thick Qty Qty 750(2'Pipe) Swivel 1081{22 ga Vert) 170 Vertical(Luminaire) i. ■ w :``� X-Press 20 829(45°Of'VedI 283 Vertical(Conduit&Cable) y 233 @ 45'(Conduit&Cable) 1■ 1250(3-1P2'Pipe) Yk swivel 1675{i6ga Vert) 250 Vertical(Luminaire) G 3(8' 8295922 SXP 35 X-Press 35 1558(89'Olt verti Im @ 90•(Luminaire) 059' 635(2'Pipe) .029" .125' 25 125 Purim 500 Vertical(Conduit 8 Cable) 333 t 89'(Conduit 8 Cable) iITIL tit Swivel 1061(22 ga Vert) fir 8272957 SXP 2.0 X-Press 2.0 B29{45"Oh Vera) 027' .125' 25 125 Metal Deck Svmrel 1675(16 qa Vert) 1T2' 8271957 SXP 35 060' .125, XPress65 1558(89'OfrVerb 25 125 Pullin • SAMMY X-PRESS I Installation Tool TS Application Product Features x `� •The Sammy X-Press expands to provide ro r ,., `� direct vertical attachment in: N. • metal deck(22-16 gauge) :1-'`'‘ "'� , ' . . (. -z-pudin(18-16 gauge) ilk .4'k i - 1 •Manufactured in the U.S A. l 111 a4arWao 4maiws4ovw ;.. � www.ihvbuildex.com) y Part Number Model Description Qty 8194910 UXPIT' Universal X-Press It Tool 1 8152910 XPOB 25164"Drill Bit 1 'Tool includes.Sleeve,84 Receiver.Hex wre dr,and 2564'DM Bit. 41 • 9 To find a distributor near you,call 800-BUILDEX SAMMYS® DESCRIPTION/SUGGESTED SPECIFICATIONS Sammy X-Press Revolutionizes The Pipe SammyHanding Trades— The Sammy X-Press.System is designed to provide direct attachment of threaded rod in metal deck X Press o (22-16 gauge)and thin gauge purlin(18-16 gauge),while providing reduced installation costs in terms of time and materials. The X-Press Anchors eliminate the need for costly"armovers"in pipe hanging installations. Current methods offered for thin gauge purlin require use of a time-consuming retaining /, nut on the threaded portion of the fastener to prevent pullout Installs into and are not designed for use in metal deck.In many instances, . . access to the backside of the installed fastener is prohibited Metal Deck, by panel liner or roofing insulation. Sammy X-Press°anchors deliver the performance installers require without the use of a Purlin, or retaining nut! ubul' r Steel mmy X-Press The patent-pending X-Press Anchors consist of a threaded fastener and expandable sleeve. The X-Press System features an easy-to-install anchor with expanding anchoring strips that collapse to prevent pullout after installation. The Sammy X-Press°It Installation Tool assures a perfect installation every time offering the added convenience of one-tool efficiency—just drill and drive in seconds! SECONDS! ) ADVANTAGES E Installs in seconds,saving time& ■ Less jobsite material needed. • installation costs. ■ ■ No retaining nut required. per Use in applications where access to the back of ■ Provides design flexibility. the installed fastener is prohibited.ie.metal .. • roof deck,tubular steel,or vapor barrier fabric. Sammy's X-Press, Swivel and Sidewinder The Sammy X-Press expands to provide t directvertical attachment in: VP)' 11 -Metal Deck(22-16 gauge) Patent t''6,935,821 , I., -Z-Purin(18-16 gauge) 6,935,11 A'� The Sammy X-Press Swivel allows you to hang plumb in extreme roof pitches: r SWXP) I -89°in Z-Pudin Patent Pending -45°in metal deck for 12/12 pitch 1 FOR The Sammy X-Press Sidewinder expands )SxP) EXTpa. t to provide horizontal attachment in: oil Patent Pending ` T -16 ga-3/16"steel-purlin,tubular steel. • ITN' SAMMYS° u c forgeoon Products S 1 1 Call Wall free number800-387-9692awsit www.i wmnstrvnion.o general information. LL VMt nw BuildeKtSAMMYSweb sue wian sammysuperscrew.com lathe most current produn and technical information. Sammy APPLICATIONS APPROVALS ' Sprinkler Systems The X-Press System has earned the 9R21 and 25E5 UL Listing. • fa Pipes/Plumbing Electrical Lighting and Fixtures HVAC Equipment and Fixutres 4011b- .00,011"""r. I :,j x.5 .:.1 d.. .. n +' R gv . r rgr • INSTALLATION TOOL SAMMY X-PRESS IT' INSTALLATION TOOL INSTALLATION INSTRUCTIONS UXPIF Y PART MODEL DESCRIPTION EACH NUMBER QTY -- 3 8194910 UXPIT' Universal X-Press It Tool 1 t , .Pre-Drill. . Attach Sleeve. . Insert Anchor. 4. Install. 8152910 XPOB 25/64"Drill Bit 1 To watch a video demonstration of the SammyX-Press visithttp://www.sammysaperscrew.com/sammyxpress.htm "Tool Includes:Sleeve,Bit Receiver,Hex Wrench,and 25/64"Drill Bit. • IT OF Construction Products Callum toll free number 800-387-9692 or visit www.itwconstruaion.e for general infosmatbn. SAMMYSH S 13 Visit I1W Builder's SAMMYS web site www.sammysulwnaew.mm for the most anent product and technical information. Sammy X-Press SELECTION CHART SAMMYS X-Press Vertical Mount ROD PART ULTIMATE ® TEST ® TEST MIN MAX BOX CASE SIZE NUMBER MODEL DESCRIPTION PULLOUT s LOAD LOAD THICK THICK QTY QTY APPLICATION (LBS) Lister (LBS) APPROVED (LBS) .Ay in 1/4" 8181922 XP200 X-Press200 .125" 25 125 Metal Deck 1146 185(Luminaire) .027" (22ga) 250(Luminaire) 056" )(Pi 850(216"Pipe) Patent No I i 1146 185(Luminaire) 940(2"Pipe) .027" 6935,821 3/8" 8150922 XP20 X-Press20 (22ga) 250(Luminaire) 1475(4"Pipe) .027" .125" 25 125 Metal Deck 283(Conduit&Cable) 056" 1250(3W'Pipe) .060" 3/8" 8153922 XP 35 X-Press 35 1783 85(Luminaire) 940 (2"Pipe) .105" .125" 25 125 Purlin (16ga) 250(Luminaire) 1475(4"Pipe) .027" 416(Conduit&Cable) .056" Metal Deck 3/8" 8150922 XP 20 Sammy 1146(22ga) 850(2'�Pipe) Pre-Pour Structural Concrete@ 3000 psi 25 125 (Pre-Pour) X-Press 20 Post-Pour Range II LWC<35 PCF(Ibs/ft) Metal Deck (Post-Pour) Villnilt Pre-Pour S1Net,oi(onaete @ 3008psI PostPos-Pour Range II LW(535 PCP(WO/ft') a SAMMYS X-Press Swivel Head° . ROD PART ULTIMATE TEST TEST MIN MAX BOX CASE 11 SIZE NUMBER MODEL DESCRIPTION PULLOUT c us LOAD ® (069) THICK THICK QTY QTY APPLICATION (LBS) LISTED APPROVED 750(2"Pipe) 170 vertical(Luminaire) ISZPI 80@45°(Luminaire) Ma Swivel 1061(22 ga Vertical) Pe rPending / root 3/8" 8294922 SXP 20 X-Press 629(45°OffVertical) 283 vertical 635(2"Pipe) .027" .125" 25 125 Metal Deck (Conduit&Cable) V QWaa 233 @ 45° for P)1CllEs (Conduit&Cable) 1500(4"Pipe) 250vertical(Luminaire) Swivel 1675(16 ga Vertical) 80 @ 90°(Luminaire) 3/8" 8295922 5XP35 SOOvertical .060" .125" 25 125 Purlin X-Press 35 1558(89°Off Vertical) (Conduit&Cable) 635(2"Pipe) 333 @ 89° (Conduit&Cable) 1/2" 8272957 SXP2.0 Swivel 1061(22 ga Vertical) .027" .125" 25 125 Metal Deck X-Press 2.0 829(45°Off Vertical) 1/2" 8271957 SXP3.5 Swivel 1675(16gaVerrical) .060" .125" 25 125 Purlin X-Press 3.5 1558(89°Off Vertical) SAMMYS X-Press Horizontal Mount ROD PART ULTIMATE ink TEST TEST MIN MAX BOX CASE SIZE NUMBER MODEL DESCRIPTION PULLOUT $ LOAD ® LOAD THICK THICK QTY QTY APPLICATION (LBS) usTED (LBS) we.r°.r° (LBS) ' Sidewinder 1250(3Yz"Pipe) . 3/8" 8293957 SWXP35 X-Press35 1798(16ga) 80(Luminaire) .060" .125" 25 125 Purlin tent Pending 416(Conduit&Cable) isWXP) Construction Products S 14 SAMMYS. Call our toll free number 888-387-9492 or visit www.itwconstruction.ca for general information. Visit ITW 6uildeis SAMMYSweb site www.sammrsunerscrew.com for the most torrent product and technical information. SAMMYS X-Press for Seismic Restraint f-Swivels-tom DESCRIPTION 45°to ensure i proper FEATURES BENEFITS installation! IN Structural attachment and IN Reduced installation cost. restraint component combined; ■ Design flexibility. I • ready for selected rod. IILess on site material(GO GREEN). ', ,\ ■ Access to the back of fastener I Less material coordination. not required. ■ : ■ Does not require use of a ■ Aesthetically pleasing. Ailik Cori-Purim MetalDecx retaining nut. ( s � TO �1 ■ Quick and easy installation. 4.. Q� ,RE r f/IREMEN la FOR 3/8" AND 1/2" RODS SPECIFICATIONS \`'',- ce,- `IE ►1 1 1 SXP 20 AND SXP 35 FOR 3/8"ROD FOR 3/8"ROD AND 1/2"ROD j c c,o,E. LEs E. r. f Structural attachment for installation of branch/end of line restraint using Restrained Pipe Size: Up to Schedule 40 pipe 2"or less 3/8"all thread(.299"OD)or end thread rod(.374"OD). Max Length of SXP 20 for 3/8"Rod:Designed for use in metal deck ranging from 22 ga. Restraint Material: See Maximum Horizontal Load Tables below. through 18 ga.in low slope or pitched roof designs(12/12). Maximum Angle: 45°from horizontal SXP 35 for 3/8"Rod:Designed for use in steel purlin ranging from 16 ga. Material: Carbon Steel through 1/8"in low slope or pitched roof designs(12/12). The Swivels may be used to attach short length of rod to eliminate lateral Screw Description: 1/4"-20 x 1 1/8"with expandable sleeve sway bracing per NFPA 13,9.3.5.3.8,(2007). Finish: Electro-Zinc SXP 2.0 AND SXP 3.5 FOR 1/2"ROD Testing: Tested to GR-63-CORE Standard for performance in Structural attachment for installation of branch/end of line restraint using structural steel in seismic restraint applications as outlined for use in NFPA 0 1/2"all thread(.405"OD)or end thread rod(.500"OD). 9.3 at an independent test lab.The calculated force used for the testing wass equa equa that found in a Zone 4 and an 8.4 Richter scale seismic event. SXP 2.0 for 1/2"Rod:Designed for use in metal deck ranging from 22 ga. Listing for 3/8"Rod: UL 203 listed as pipe hanger File EX 5098 FM through 18 ga.in low slope or pitched roof designs(12/12). -SXP 20(22 ga.)0-45°from horizontal-2"Schedule 40 pipe SXP 3.5 for 1/2"Rod:Designed for use in steel purlin ranging from 16 ga. -SXP 35(16 ga.)0-90°from horizontal-3-1/2"Schedule 40 pipe u�°. through 1/8"in low slope or pitched roof designs(12/12). UL 203A File EX 15565 uL . The Swivels may be used to attach short length of rod to eliminate lateral Listing for 1/2"Rod: UL 203A File EX 15565 �L , sway bracing per NFPA 13,9.3.5.3.8,(2007). ea SELECTION CHART SAMMYS X-Press Swivels -Seismic Restraint ROD PART MODEL MIN MAX APPLICATION BOX CASE INSTALLATION TOOL SIZE NUMBER THICKNESS THICKNESS QTY QTY 3/8" 8294922 SXP 20 22 ga 18 ga- Metal Deck 25 125 1/2" 8272957 SXP 2.0 22 ga 18 ga. Metal Deck 25 _ 125 The SWXP 35 must be installed 3/8" 8295922 SXP 35 16ga 1/8" Pullin 25 125 819 WWII re-1(Part e. 8194910);p(e-drilling required. 1/2" 8271957 5XP3.5 16ga 1/8" Purlin 25 125 PERFORMANCE TABLES Maximum Rod Length for I/r=100, 200, 300, and 400 Least Radius of Maximum Rod Length for Ur(ft) Restraint Shape and Size Nominal Diameter Area(in?) Gyration,r(in.) Vr=100 17r=200 Vr=300 Ur=400' Rods(all thread) 3/8 in. 0.07 0.075 0.6 1.3 1.9 2.5 1/2in. 0.129 0.101 0.8 1.7 2.5 3.4 3/8 in. 0.11 0.094 0.8 1.6 2.4 3.1 • Rods(threaded at ends only) 1/2in. 0.196 0.125 1.0 2.1 3.1 4.2 Reference:� NFPA 13,(2007) *Reference:NFPA 13,(2010) L%V Construction Products Call our toll free number800-387-9692 or visit www.ltwmnmucnon.cafor general information. SAMMY& 515 r5Visit ffW Buddee s SAMMYS web site www.sammysupersaew-mm for the most current product and technical information. Y X-Press r eisSeismic estraint 'TE !�° ` TO DESCRIPTION (SIDEWINDER) I E.,. ,,E (:E M WXP 35 FOR 3/8"ROD �: s \aCA• ftESIE t, tructural attachment for installation of branch/end of line restraint using l gE(gy(tc OEs j, 3/8"threaded rod.Used primarily in purlin,bar joist,or other steel structural CAOOREBf members.These fastening systems provide a secure and economical attachment to the structure. - The SWXP 35 model provides upper structural attachment in a range of steel J thicknesses,from 16 ga.through 1/8".An expandable sleeve is included with each fastener,eliminating need for retaining nut. a ' SPECIFICATIONS g. Restrained Pipe Size: Up to Schedule 40 pipe 2"or less Max Length of J- 7-7 Restraint Material: See Maximum Horizontal Load Tables below. ^ - 0 ‘ i Maximum Angle: 45°from horizontal / ,. „.'. Material: Carbon Steel Swf feiS 10 45D le Screw Description: 1/4"-20 X 1-1/8"with expandable sleeve ensure proper Finish: Electro-Zinc(cap&screw) installation! Testing: BX Report#R-1362 Listing: UL 203 as a pipe hanger Mk • UL 203A pending NIS LISTED B SELECTION CHART .. SAMMYS Sidewinders for Concrete -Seismic Restraint ROD PART MODEL MIN MAX APPLICATION BOX CASE INSTALLATION TOOL SI2E NUMBER THICKNESS THICKNESS QTy orb' The SWXP 35 must be installed 3/8" 8293957 SWXP 35 16ga. 1/8" Steel Pullin orBarloist 25 125 with UXPIT Tool(Part No.8194910), pre-drilling required. PERFORMANCE TABLES Maximum Horizontal Loads for Restraint with I/r=100, 200, 300, and 400 Restraint Shape and Size Nominal Diameter Area(in?) Least Radius of Maximum Rod Length for I/r(ft) Gyration,r(in.) Ur=100 I/r=200 I/r=300 I/r=400* 3/8 in. 0.07 0.075 0.6 1.3 1.9 2.5 Rods(all thread) 1/2 in. 0.129 0.101 0.8 1.7 2.5 3.4 3/8 in. 0.11 0.094 0.8 1.6 2.4 3.1 ods(threaded at ends only) 1/2in. 0.196 0.125 1.0 2.1 3.1 4.2 ference:NFPA 13,(2007) *Reference:NFPA 13,(2010) rn� TH Construction Products S16 SAMMYS° (all our toll free number800-387-9691 or visit www.ltweonstruoion.W for general information. Visit ItW Buildei s SIMMVS web site www.sammysupersoew.com for the most current product and technical information. Seismic Bracing Fig. 4A- Pipe Clamp for Sway Bracing ®TOLCO Size Range: 4" (1o0mm)thru 8" (200mm)pipe. For sizes smaller than CO us 4" (100mm)use B3140. LimnMaterial: Steel Function: For bracing pipe against sway and seismic disturbance. B Approvals: Underwriters Laboratories Listed in the USA(UL)and Canada (cUL)4" (100mm)thru 8" (200mm). 111 Installation Instructions: Fig.4A is the "braced pipe" attachment component �7i1 of a longitudinal, lateral or riser brace assembly. It is intended to be combined / with the"bracing pipe"and Cooper B-Line/TOLCO transitional and structural 1 A attachment component(s)to form a complete bracing assembly. NFPA 13 guidelines should be followed. D ,, ,, 7 To Install: Place the Fig.4A over the pipe to be braced.Attach Cooper B-Line/TOLCO transitional fitting, either Fig.980, 910, 909, or any other Cooper B-Line/TOLCO approved transitional fitting.Tighten bolts and nuts;torque requirement is a minimum of 50 ft./lbs. (68Nm). c Me Transitional fitting attachment can pivot for adjustment to proper brace angle. Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. HHCS and Hex Nuts Included Order By: Figure number, pipe size and finish Note: Please refer to Fig. 4L for longitudinal brace applications for 4 a 2"(50mm)-8"(200mm)pipe sizes i .r 47 III I, ,,, i N Fig.4A-Longitudinal Brace N Pipe Max.Horizontal Approx. Part Size A B C D Bolt Design Load Wt./100 No. in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) Size lbs. (kN) lbs. (kg) 4A-4 4 (100) 81/2 (215.9) 9/16" (14.3) 33/8" (85.7) 311/16" (93.7) 1/2"-13 1600 (7.11) 221 (100.2) 4A-5 5" (125) 93/4' (247.6) 9/16" (14.3) 37/a' (98.4) 43/8' (111.1) 1/2"-13 1600 (7.11) 253 (114.7) 4A-6 6" (150) 111/2' (292.1) 5/8" (15.9) 5" (127.0) 51/8' (130.2) 1/2"-13 2015 (8.96) 513 (232.7) 4A-8 8" (200) 131/4' (336.5) 3/4" (19.0) 611/16' (169.9) 61/8" (155.6) 1/2"-13 2015 (8.96) 601 (272.6) Cooper B-Line, Inc.'s("Cooper B-Line")seismic bracing components are designed to be compatible only with other Cooper B-Line bracing components,resulting in a listed seismic bracing assembly.Cooper-B-Line's warranty for seismic bracing components will be • the warranty provided in Cooper B-Line's standard terms and conditions of sale made available by Cooper B-Line,except that,in addition to the other exclusions from Cooper B-Line's warranty,Cooper B-line makes no warranty relating to Cooper B-Line's seismic bracing components that are combined with products not provided by Cooper B-Line. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line Seismic Bracing Fig. 980 - Universal Swivel Sway Brace Attachment - 3/B" to 3/4" ®TOLCO Size Range: One size fits bracing pipe 1" (25mm)thru 2" (5omm), Cooper C US B-Line 12 gauge(2.6mm)channel, and all structural steel up to 1/4"(31.7mm)thick. LISTED Material: Steel Function: Multi-functional attachment to structure or braced pipe fitting. i Features: This product's design incorporates a concentric attachment `` opening which is critical to the performance of structural seismic connections. ��`� NFPA 13 indicates clearly that fastener table load values are based only on ,, �)� D concentric loading. Mounts to any surface angle. Break off bolt head assures verification of proper installation. _ �� Installation: Fig.980 is the structural or transitional attachment component A of a longitudinal or lateral sway brace assembly. It is intended to be combined _/ B with the'bracing pipe" and Cooper B-Line/TOLCO "braced pipe" attachment, Fig. 1000, 1001,2002, 4L, 4A or approved attachment to pipe to form a Set Bolt complete bracing assembly. NFPA 13 guidelines should be followed. Included Mounting Hardware To Install: Place the Fig. 980 onto the "bracing pipe".Tighten the set bolt until Is Not Included the head breaks off.Attachment can pivot for adjustment to proper brace angle. Approvals: —Underwriters Laboratories Listed in the USA(UL)and Canada(cUL). For FM Approval information refer to page 61. Note: Fig.980 Swivel Attachment and Fig. 1001, 1000,2002,4A or approved attachment to pipe that make up a sway brace system of UL Listed attachments and bracing materials which satisfies the requirements of Underwriters Laboratories and the National Fire Protection Association (NFPA) Finish: Plain, Electro-Galvanized or Stainless Steel. Contact Cooper B-Line for alternative finishes. Order By: Figure number and finish. • Pat.#6,273,372, Pat.#6,517,030,Pat.#6,953,174, -- Fig.980 jr i Pat.#6,708,930, Pat.#7,191,987, Pat.#7,441,730, r. Pat.#7,669,806 r r 441110V( Fig.4L 44, Lateral Brace } Longitudinal Brace Part Mtg.Hdw. Mounting Hole Max.Design Approx. Number Size A B D Load(cULus) Wt./100 in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) lbs. (kg) 980-3/8 Es (9.5) EMI (133.3) 17/8" (47.6) 13/32" (10.3) 2015 (8.96) 149 (67.6) 980-1/2* ® (12.7) 51/4" (133.3) 17/8" (47.6) 17/32" (13.5) 2015 (8.96) 148 (67.1) 980-5/8 Ell (15.9) 51/4" (133.3) 17/8" (47.6) 11/16" (17.5) 2015 (8.96) 147 (66.7) 980-3/4 leil (19.0) 51/4" (133.3) 17/8" (47.6) 13/16" (20.5) 2015 (8.96) 146 (66.2) *Standard size. Cooper B-Line,Inc.'s("Cooper B-Line")seismic bracing components are designed to be compatible only with other Cooper B-Line bracing components,resulting in a listed seismic bracing assembly.Cooper-B-Line's warranty for seismic bracing components will be • the warranty provided in Cooper B-Line's standard terms and conditions of sale made available by Cooper B-Line,except that,in addition to the other exclusions from Cooper B-Line's warranty,Cooper B-line makes no warranty relating to Cooper B-Line's seismic bracing components that are combined with products not provided by Cooper B-Line. AU dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. 60 001 COOPER B-Line Seismic Bracing Fig.4L- Longitudinal "In-Line"Sway Brace Attachment --�� cCOus �► III SizeRange: 2" (50mm)through 8" (200mm)ips. � uSiED Material: Steel , Function: For bracing pipe against sway and seismic disturbance. set scrl included .P'��7//i -%-i Approvals: Underwriters Laboratories Listed in the USA(UL)and Aim Canada(cUL)21/2"(65mm)through 8"(200mm)pipe.Approved by Factory ri l Mutual Engineering(FM),2"(50mm)through 8"(200mm)pipe. Installation Instructions: Fig.4L is the"braced pipe"attachment component of a longitudinal sway brace assembly. It is intended to be D A combined with the"bracing pipe"and Cooper B-Line/TOLCO structural attachment component to form a complete bracing assembly.NFPA 13 and/or coOSHPD guidelines should be followed. c •g m To Install: Place the Fig.4L over the pipe to be braced and tighten co bolts.Then engage"bracing pipe" into jaw opening and tighten set screw c t 2 until head snaps off.Jaw attachment can pivot for adjustment to proper E brace angle. �� m Finish: Plain.Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number,pipe size and finish. `r 7.4n , � Longitudinal 4-Way Riser Brace t. El Brace (plan view) 44., § III Pipe Max.Rec.Load *Max.Design Load Approx. Part Size A C D Bolt Size (cULuc) (FM) Wt./100 No. in. (mm) in. (mm) in. (mm) in. (mm) lbs. (kN) lbs. (kN) lbs. (kg) 4L-2 ® (50) 53/8" I (136.5) 21/16' (52.4) 2 /16" (52.4) 1/2"-13 2015 (8.96) -- (--) 247 (112.0) 4L-21/2 21/2' (65) 67/16" (163.5) 21/2' (63.5) 23/4" (69.8) 1/2"-13 2015 (8.96) 3000 (13.34) 253 (114.7) 4L-3 3" (80) 7" ' (177.8) 23/4" (69.8) 31/16" (77.8) 1/2"-13 2015 (8.96) 1550 (6.89) 268 (121.5) 4L-4 4" (100) 81/2" (215.9) 33/8" (85.7) gus (93.7) 1/2"-13 2015 (8.96) 1550 (6.89) 348 (157.8) 41-5 ® (125) 93/4" 1 (247.6) 37/8" (98.4) 43/8" (111.1) 1/2"-13 2015 (8.96) 1450 (6.45) 380 (172.3) 4L-6 (150) 111/21(292.1) 5" (127.0) 51/8' (130.2) 1/2"-13 2015 (8.96) 1450 (6.45) 640 (290.3) 4L-8 (200) 131/4" (336.5) 55/s" c 55/e' (142.9) 1/2"-13 2015 (8.96) 1450 (6.45) 728 (330.2) Pipe Max.Rec.Load *Max.Design Load(FM) Part Size (cULuc) 30°-44° 45°-59° 60°-74° 75°-90° No. in. (mm) lbs./(kN) lbs. (kN) lbs. (kg) *The loads listed are axial loads on the brace. 4L 2 2" The horizontal load capacity, H,of the (50) 2015(8.96) brace is:H=F x sin?,where?the installation 4L-21/2 BEM 2015(8.96) 1030(4.58) 1180(5.24) 1420(6.31) 1590(7.07) angle measured from the vertical. 4L-3 ® (80) 2015(8.96) 1030(4.58) 1180(5.24) 1420(6.31) 1590(7.07) FM approved when used with 1", 11/4", 11/2"or 4L-4 4' (100) 2015(8.96) 530(2.36) 730(3.25) 890(3.96) 990(4.40) 2" Sch.40 brace pipe. 4L-5 5' (125) 2015(8.96) 530(2.36) 730(3.25) 890(3.96) 990(4.40) 4L-6 6' (150) 2015(8.96) 530(2.36) 730(3.25) 890(3.96) 990(4.40) 4L-8 Ex (200) 2015(8.96) 490(2.18) 680(3.02) 830(3.69) 930(4.13) Cooper B-Line,Inc.'s("Cooper B-Line")seismic bracing components are designed to be compatible only with other Cooper B-Line bracing components,resulting in a listed seismic bracing assembly.Cooper-B-Line's warranty for seismic bracing components will be the warranty provided in Cooper B-Line's standard terms and conditions of sale made available by Cooper B-Line,except that,in el addition to the other exclusions from Cooper B-Line's warranty,Cooper B-line makes no warranty relating to Cooper B-Line's seismic bracing components that are combined with products not provided by Cooper B-Line. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line Seismic Bracing Fig.800-Adjustable Sway Brace Attachment to Steel j, Component of State of • California OSHPD Approved Size Range: 4"(101.6mm)thru 18" (457.2mm)beam width Seismic Restraints System Material: Steel Function: Seismic brace attachment to steel. c 'gL us 44> Features: This product's design incorporates a concentric attachment point which is - LISTEDcritical to the performance of structural seismic connections.NFPA 13 indicates the Pr.... `importance of concentric loading of connections and fasteners.Permits secureconnection to steel where drilling and/or welding of brace connection could present structural issues. : Installation Instructions: Fig.800 is the structural attachment component of a 0 longitudinal or lateral sway brace assembly.It is intended to be combined with a 0,1 w Cooper B-Line/TOLCO transitional attachment, "bracing pipe"and a Cooper I O 3 B-Line/TOLCO"braced pipe"attachment to form a complete bracing assembly. 1 mNFPA 13 and/or OSHPD guidelines should be followed. Set Screws&Hardware a To Install: Place the Fig.800 on the steel beam,tighten the cone point set screws Included =t .; on flange until the heads break off.Tighten hex head bolts into clamp body until lock washers are fully flat.Attach other Cooper B-Line/TOLCO transitional attachment fitting,Fig.909,910,980 or 986.Transitional fitting attachment can pivot for ' adjustment to proper brace angle. itas Approvals: Underwriters Laboratories Listed in the USA(UL)and Canada(cUL). Approved by Factory Mutual Engineering(FM).Included in our Seismic Restraints meµ, Catalog approved by the State of California Office of Statewide Health Planning and Development(OSHPD). For additional load,spacing and placement information relating to OSHPD projects,please refer to the Cooper B-Llne,TOLCO Seismic Restraint Systems Guidelines. ` ` Finish: Plain.Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number and size,type number. • Fits Beam Part No. Flange Width ,.., ar ,AN in. (6-1 win®�� r�w 800-1 4"-6" (101.6-152.4) � M senp800-2 6"-8" (152.4-203.2) fie w 'Si 800-3 8"-10" (203.2-254.0) . 1&1 800-4 10"-12" (254.0-304.8) Shown with Fig.980 Shown with %I brace fitting to Fig.980 brace i I 800-5 12"-14 (304.8-355.6) / , v"- pipe brace fitting to pipe brace I 800-6 14"-16" (255.6-406.4) (Across Beam) (Along Beam) 1 I 800-7 16"-18" (406.4-457.2) Maximum Max.Design Loads(cULus) Max,Design Load(FM) Type Flange Thickness Along Beam Across Beam Laterial-Parallel to Structural Member Longitudinal-Perpendicular to Structural Member 30°-44° 45°-59° 60°-74° 75°-90° 30°-44° 45°-59° 60°-74° 75°-90° in. (aim) lbs./(kN) lbs./(kN) lbs./(kN) lbs./(kN) lbs./(kN) lbs./(kN) lbs./(kN) lbs./(kN) lbs./(kN) lbs./(kN) 1 3/4" (19.0) 1265 2015 1430 1970 1980 NR 930 1310 1610 1800 (5.62) (8.96) (6.36) (8.76) (8.81) (NR) (4.13) (5.82) (7.16) (8.00) 2 It/a" (31.7) 1265 2015 NR NR NR NR NR NR NR NR (5.62) (8.96) (NR) (NR) (NR) (NR) (NR) (NR) (NR) (NR) Cooper B-Line,Inc.'s("Cooper B-Line")seismic bracing components are designed to be compatible only with other Cooper B-Line bracing components,resulting in a listed seismic bracing assembly.Cooper-B-Line's warranty for seismic bracing components will be • the warranty provided in Cooper B-Line's standard terms and conditions of sale made available by Cooper B-Line,except that,in addition to the other exclusions from Cooper B-Line's warranty,Cooper B-line makes no warranty relating to Cooper B-Line's seismic bracing components that are combined with products not provided by Cooper B-Line. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. 170 Seismic Bracing Component of State of Fig.825- Bar Joist Sway Brace Attachment l California OSHPD Approved III Seismic Restraints System Size Range: One size accommodates all M Fig.900 Series sway brace attachments.Maximum CC Horizontal Design Load 2015 lbs(8.96kN). . Material: Steel 0 *4 ��- Function: To attach sway bracing and hanger assemblies - ; .. '7 r •11 (9•5) to steel open web structural members. i ��� Features: This product's design incorporates a concentric ®tI Nit►�r lt attachment point which is critical to the performance of L p�0 (�� 411114�� structural seismic connections.NFPA 13 indicates the "�1 $s �� . importance of concentric loading of connections and N„. � fasteners.Permits secure non-friction connection without CD drilling or welding. Unique design reinforces point of connection to joist.Break off head set screws a co set screw design assures verification of proper installation torque(min.31 ft.-lbs.). Hardware Included r`n 0 Approvals: Underwriters Laboratories Listed in the USA(UL)and Canada(cUL). E Approved by Factory Mutual Engineering(FM).Included in our Seismic Restraints Maximum Design Load 2015 lbs.(8.96kN) m Catalog approved by the State of California Office of Statewide Health Planning and to Development(OSHPD).For additional load,spacing and placement information UL Listed as Hanger Attachment for relating to OSHPD projects,please refer to the Cooper B-Line/TOLCO Seismic 6"(150mm)Pipe at Maximum Spacing Restraint Systems Guidelines. Installation Instructions: Fig.825 is the structural attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with a TOLCO transitional attachment, "bracing pipe and a Cooper B-Line/TOLCO — — — — — — -- "braced pipe"attachment,to form a complete bracing assembly. NFPA 13 and/or T _ ____— n--0_-�IL-_-_- -R OSHPD guidelines should be followed. ' To Install: Place the Fig.825 on the steel beam,tighten the conepoint set screws 1., I— — — — — 9 (25.4mm) n,.:. until heads break off.Attach other Cooper B-Line/TOLCO transitional attachment '/2"Bolt&Nut • fitting,Fig.909,910,980 or 986.Transitional fitting attachment can pivot for Top View Furnished adjustment to proper brace angle. Finish: Plain, Electro-Galvanized and Max Er. Shown with HDG Bar joist shown attached to 16"052.4mm)) Fig.910 Approx.Wt./100: 247.5 Lbs. (112.2kg) various roof materials Fig. Fig.1000 Order By: Figure number and finish ; 825 US Patent ##6,098,942, jar shown with ! Canada Patent#2,286,659 Fg.910 .L_ ny May pivot in any May pent in any idirection direction Front View Side View Shown with 1 lin, Fig.910 pi FM Approved Design Loads Fig.825 30°-44° 45°-59° 60°-74° 75°-90° lbs.!(kN) lbs./(kN) lbs,/(kN) lbs./(kN) Fig.1000 Maximum Lateral-Parallel to 990 1360 1670 1860 J-L 3/s"Thick Flange Structural Member ((4.40) (6.05) (7.43) (8.27) Longitudinal- Maximum Perpendicular to 460 630 770 860 3/a"Thick Flange Structural Member ((2.04) (2.80) (3.42) (3.82) J Cooper B-Line,Inc.'s("Cooper B-Line")seismic bracing components are designed to be compatible only with other Cooper B-Line bracing components,resulting in a listed seismic bracing assembly.Cooper-B-Line's warranty for seismic bracing components will be • the warranty provided in Cooper B-Line's standard terms and conditions of sale made available by Cooper B-Line,except that,in addition to the other exclusions from Cooper B-Line's warranty,Cooper B-line makes no warranty relating to Cooper B-Line's seismic bracing components that are combined with products not provided by Cooper B-Line. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line Seismic Bracing Fig. 1001 - Sway Brace Attachment Component of State of California OSHPD Approved • ,,,F Seismic Restraints System Size Range: Pipe size to be braced:21/z"(65mm)thru 8" (200mm)IPS. *Pipe size used for bracing: 1" (25mm)and 11/4" (32mm)Schedule 40 IPS. COUS Material: Steel LISTED Function: For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace system: Fig. 1001 is used in conjunction with a Fig.900 Series fitting and joined together with bracing pipe per NFPA 13, forming a complete sway brace assembly. Features: Can be used to brace schedules 7 through 40 IPS. Field adjustable, making critical pre-engineering of bracing pipe length unnecessary. Unique design w requires no threading of bracing pipe. Can be used as a component of a four-way riser brace.Comes assembled and ready for installation. Fig. 1001 has built-in lit 3 visual verification of correct installation.See installation note below. 03 Installation Note: Position Fig. 1001 over the pipe to be braced and tighten Set Screws . f,i 3 two hex head cone point set screws until heads bottom out.A minimum of �� Included a " 44 1 (25mm)pipe extension is recommended. Brace pipe can be installed on top or 3- 11:1 bottom of pipe to be braced. Approvals: Underwriters Laboratories Listed in the USA(UL) r and Canada(cUL).Approved by Factory Mutual Engineering(FM)and Canada 1,„ (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development(OSHPD). For additional load,spacing and placement information relating to OSHPD projects, please refer to the Cooper B-Line/TOLCO Seismic Restraint Systems Guidelines. UL Listed Design Load Finish: Plain.Contact Cooper B-Line for alternative finishes and materials. Sch.7 - 1600 lbs.(7.11kN) Order By: Indicate pipe size to be braced followed by pipe size used for bracing, Sch.10&40 w/1"(25mm)Brace Pipe figure number and finish. 2015 lbs.(8.96kN) Important Note: Fig. 1001 is precision manufactured to perform its function as Sch.10&40 w/11/4"(32mm)Brace Pipe • a critical component of a complete bracing assembly.To ensure performance, the 2765 lbs.(12.3OkN) UL Listing requires that Fig. 1001 must be used only with other Cooper B-Line/ TOLCO bracing products. Pipe Part Number&Approx.Wt./100 Design Load-Allowable Horizontal Capacity(Ibf)Per Installation 1,2,3 Size 1"(24mm)Brace Pipe 11/4"(32mm)Brace Pipe 30°-44° 45°-59° 60°-74° 75°-90° in. (mm) Lbs. (kg) Lbs. (kg) Lbs. (kN) Lbs. (kN) Lbs. (kN) Lbs. (kN) 21/2 (65) 1001-21/2 X 1 138.6 (62.8) 1001-21/2 X 11/4 160.4 (72.7) 800 (3.56) 1130 (5.02) 1380 (6.14) 1540 (6.85) 3" (80) 1001-3 X 1 147.2 (66.7) 1001-3 X 11/4 168.7 (76,5) 850 (3.78) 1200 (5.34) 1470 (6.54) 1640 (7.29) 4" (100) 1001-4 X 1 160.9 (73.0) 1001-4 X 11/4 182.4 (82.7) 850 (3.78) 1200 (5.34) 1470 (6.54) 1640 CM 6" (150) 1001-6 X 1 190.0 (86.2) 1001-6 X 11/4 211.4 (95.9) 510 (2.27) 730 (3.25) 890 (3.96) 990 (4.40) 8" (200) 1001-8 X 1 217.4 (98.6) 1001-8 X 11/4 238.8 (108.3) 510 (2.27) 730 (3.25) 890 (3.96) 990 (4.40) 1 FM Approved when used with 1,11/4,11/2,or 2 inch NPS Schedule 40 GB/T 3091,EN 10255H,or JIS G3451 steel pipe as the brace member. 2 Load rating for LW above refers to FM Approved Lightwall Pipe commonly referred to as"Schedule 7".These ratings may also be applied when EN 10220 and GB/T 8163 steel pipe. 3 Load rating for Schedule 10 above may be applied to GB/T 3092,EN 10255M and H,or JIS G3454,FM Approved Thinwall, or Schedule 40 steel pipes. Note:See UL load ratings in UL Listed Design Load chart shown under drawing. 11),-'-'-'. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. 186 Pipe Clamps Fig. 22 - Hanger for CPVC Plastic Pipe • Single Fastener Strap (Cooper B-Line B3181) klc UL us LISTED Size Range: 3/4°(20mm)thru 2"(50mm)CPVC pipe Material: Pre-Galvanized Steel c Function: Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems.The product acts as a hanger when tab is upward and the fastener screw is in the horizontal position. Fig.22 can be installed on the top of a beam, but in this situation acts as a guide to the piping which is supported by the beam itself. It is not intended to support /. �) CPVC pipe from under a flat horizontal surface,such as a ceiling. Approvals: Underwriters Laboratories Listed in the USA(UL)and Canada (cUL)to support fire sprinkler piping. May be installed in wood using \ fasteners supplied with product, or into minimum 20 gauge(0.9mm)steel using (1) 1/4"x 1"tek type screw. Meets and exceeds the requirements of NFPA 13, 13R and 13D. q ' Features: Fig.22 incorporates features which protect the pipe and ease installation.The flared edge design protects CPVC pipe from any rough 1 surface. It is easily attached g e building structureed using the c. It special UL / Listed hex head self threading screw*furnished with the product. It is f/// recommended that rechargeable electric drills fitted with a hex socket attachment to be used as installation tools. No impact tools(such as a hammer)are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish: Pre-Galvanized A1=' 'jag i A Order By: Figure number and CPVC pipe size. *Hardened hex head self threading screw is furnished with the • product and is the minimum fastener size acceptable. '1444- CPVC Max. Hanger Fastener Hex Approx. Pipe Size A B C Spacing Head Size Wt./100 Part Na. in. (mm) in. (mm) in. (mm) in. (mm) Fl. (m) in. (mm) Lbs. (kg) 22 3M ' ' ' . 20 27/16" 61.9 15/16" En 13/16" 30.2 51/2 (1.67 5/16" 7.9 9 (4.1) 22-1 211/16" 68.3 17/16" 36.5 13/16" 30.2 6 1,83 5/16" 7.9 9 131111 22.11/4 11/4" (32) 3/16" 77.8 15/8" 42.3 13/16" 30.2) 61/2 (1.98) 5/16' (7.9) 11 (5.0) ® ■ 11/2" 40 35/16" 13/4. M' 13/16" 30.2 7 nall 5/16 7.9) 12 ME 22-2 2' (50) 33/4" (95.2) 21/8' (54.6) 13/16" (30.2) 8 (2.44) 5/16" (7.9) 15 (6.8) i All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. ...., 93 f/ COOPER B-Line Pipe Clamps Fig. 23 - Hanger for CPVC Plastic Pipe Double Fastener Strap (cooper B-Line B3182) d t1 COOS •M LISTED Size Range: 3/4" (20mm)thru 3' (80mm)CPVC pipe Material: Pre-Galvanized Steel Function: Intended to perform as a hanger to support CPVC piping -' used in automatic fire sprinkler systems. Fig.23 can be installed , on the top, bottom or side of a beam. Approvals: Underwriters Laboratories Listed in the USA(UL) ; and Canada(cUL)sizes 3/4" (2omm)thru 2" (50mm)to support fire sprinkler piping. May be installed in wood using fasteners supplied with product,or into minimum 20 gauge(0.9mm)steel using(2)1/4"x 1"tek type screw. Meets and exceeds the requirements of NFPA 1, ,i 13, 13R and 13D. ,1 Features: Fig.23 incorporates features which protect the pipe �_ ) B 1 and ease installation.The flared edge design protects the CPVC pipe from any rough surface. It also incorporates snap restrainers allowing easier and faster installation. Easily attaches to the building -� B A structure using the two UL Listed hex head self threading screws* c furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools(such as a hammer)are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish: Pre-Galvanized Order By: Figure number and pipe size r' *Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. :,. • 4Y Yp'.E CPVC Max.Hanger Fastener Hex Approx. Pipe Size A B C Spacing Head Size Wt./100 Part No. in. (mm) M. (mm) in. (mm) in. (mm) Ft. (m) M. (mm) Lbs. (kg) 23-3/4 3/4" (20) 31/6" (79.4) 13/16" (39.7) 13/16' (30.2) 51/2 (1.67) 5/16' (7.9) 9 (4.1) ® 1' (25) 33/6" (85.7) 111/16" (42.9) 13/16" (30.2) 6 (1,83) 5/16" (7.9) 9 (4.1) 23-11/4 11/4' (32) 43/16" (106.4) 23/32" (53.1) 13/16" (30.2) 61/2 (1.98) 5/16" (7.9) 11 (5.0) 23-11/2 11/2' (40) 47/16" (112.7) 27/32" (56.3) 13/16" (30.2) 7 (2.13) 5/16" ' (7.9) 12 (5.4) 23-2 2" (50) 47/6' (123.8) 27/16" (61.9) 13/16" (30.2) 8 (2.44) 5/16" (7.9) 15 (6.8) 23-21/2 21/2' (65) 53/s" (136.5) 211/16" (68.3) 13/16" (30.2) Consult Factory MEI (7.9) 22 (10.0) 23-3 3" (80) 6" (152.4) 3" (76.2) 13/16" (30.2) Consult Factory 5/16" (7.9) 25 (11.3) • All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. 94 Pipe Clamps Fig. 24 - Hanger for CPVC Plastic Pipe • Double Fastener Strap Side Mounted (Cooper B-Line 63183) c0 us LISTED Size Range: 3/4" (20mm)thru 2"(somm)CPVC pipe Material: Pre-Galvanized Steel Function: Intended to perform as a hanger to support CPVC piping used in c automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. Approvals: Underwriters Laboratories Listed in the USA(UL)and / Canada(cUL)to support fire sprinkler piping. May be installed in wood using ; fasteners supplied with product, or into minimum 20 gauge(0.912mm)steel using(2) 1/4" x 1"tek type screws. Meets and exceeds the requirements of „' NFPA 13, 13R and 13D. k ", „ Features: Fig. 24 incorporates features which protect the pipe and „ ease installation.The flared edge design protects the CPVC pipe from J any rough surface. Easily attaches to the building structure using the two UL Listed hex head self threading screws*furnished with the product. It \I is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools(such as a hammer) C) are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. B----_,....`1 Finish: Pre-Galvanized B�� Order By: Figure number and pipe size A * Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. t k v • . a 3+Ogii: iv fs ((EPI CPVC Max. Hanger Fastener Hex Approx. Pipe Size A 8 C Spacing Head Size Wt./100 Part No. in. (mm) in. (mm) in. (mm) in. (mm) Ft. (m) in. (mm) Lbs. (kg) 24-/4 3/4" 20 25/16" 11 15/32" En 13/16" (30.2) 51/2 (1.67) 5/16" 7.9 9 4.1 24-1 1" M■ 25/8" 66.7 15/16' FM 13/16" 30.2 6 ME 5/16 7.9 9 EMI 24-11/4 11/4" ME 3' 76.2 11/2' rim 13/16" 30.2 61/2 (1.98) 5/16" 7.9) 11 5.0 11/2" (40) 31/4 031 15/8 En 13/16' 30.2 7 (2.13) 5/16" 7.9) 12 am 24-2 2 (50) 371/16" (93.7) 127/32" (43.6) 13/16" (30.2) 8 (2.44) 5/16" (7.9) 15 (6.8) • All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER R B-Line Pipe Clamps Fig. 28 - "Stand-Off" Hanger & Restrainer for CPVC Plastic Pipe d-- if iii cL us Size Range:-3/4" (20mm)through 2" (50mm) # LISTED • Material:—Steel, Pre-Galvanized Function:—Designed to be used as a hanger and restrainer for CPVC piping where the "stand-off"design will ease installation by eliminating the need for wood blocking. 1 Features: \ •Flared edge design protects CPVC pipe from any rough or abrasive surfaces. •Unique twist and lock design holds pipe firmly in place and allows retrofit type of installation. 1 A •The"Stand-Off"design eliminates the need for wood block extension. •Can be installed on horizontal or vertical piping regardless of mounting surface orientation. n •Attaches easily to wood structure with two hex head self-threading screws furnished with c product. •Installs easily using rechargeable electrical driver with 5/1s" (7.9mm)extension socket eliminating impact tool damage to pipe. •Attaches easily to steel,minimum 18 gauge(1.024mm)with(2)1/4"x 1"tek type self drilling tapping screws. ;� •UL Listed as a hanger and a restrainer for fire sprinkler piping. Approvals:—Underwriters Laboratory Listed in the USA(UL)and Canada(cUL)to support automatic fire sprinkler systems. May be installed into wood using fasteners , )d supplied with product, or into minimum 18 gauge steel using(2) 1/4"x 1"tek type ' screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig.28 satisfies Ck the UL vertical restraint requirement where needed. UL Listed as a hanger and vertical restraint when installed on 3/8" (9.5mm)composite wood material. Use two Fig.27B Speed Nuts when used as a hanger and restraint. Use one Fig.27B Speed Nut on the upper installed screw when used as a hanger only. Order by:—Figure number and pipe size. Pat.ff 7,455,268, Pat.U 7,832,248 'gw I Il i 'a Fig.27B f' Fig.27B n, (1) Required (2)Required ' I', , High Side of - p;) Hanger —I Application —1 7 -:a Hanger Application Hanger and Restraint �,�,.S:. Applicationrg Pipe Size A B C Approx.Wt./100 Part No. in. (mm) in. (mm) in. (mm) in. (mm) lbs. (kg) 28-3/4 3/4" (20) 31/32' (77.0) 2 (50.8) 31/2" (88.9) 18 (8.1) 28-1 1' (25) 35/16" (84.1) 23/16" (55.6) 31/2" (88.9) 21 (9.5) 28.11/4 11/4' (32) 35/8° (92.1) 23/8" (60.3) 31/2 (88.9) 23 (10.4) • 28.11/2 11/2" (40) 4" (101.6) 21/2" (63.5) 31/2" (88.9) 31 (14.0) 28-2 2' (50) 41/2" (114.3) 211/16" (68.3) 35/a" (92.1) 34 (15.4) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. 98 Pipe Clamps Fig. 28M - Offset Hanger& Restrainer for CPVC Plastic Pipe and IPS Pipe A,"` Size Range: 3/4" (20mm)thru 2' (32mm)411 -� s L OS LISTED Material: Steel, Pre-Galvanized Function: Designed to be used as a hanger and restrainer for CPVC piping or steel piping where the"stand-off"design will ease installation by eliminating the need for wood blocking. Features: • Flared edge design protects CPVC pipe from any rough or abrasive surfaces • Unique snap-on design holds pipe firmly in place and allows retrofit type of installation •The"Stand-Off"design eliminates the need for wood block extension • Can be installed on horizontal or vertical piping regardless of mounting surface orientation A •Attaches easily to wood structure with two hex head self-threading screws furnished with product • Installs easily using rechargeable electrical driver with 5/16"(7.9mm)extension socket eliminating impact tool damage to pipe •Attaches easily to steel, minimum 18 gauge(1.024mm)with(2)1/4"x 1"tek type self drilling e tapping screws • cULus Listed as a hanger and a restrainer for fire sprinkler piping a Installation Note: When installed in wood structural members and threads from the #10 x 1'screws are exposed,use Fig.27B speed nut to secure Approvals: Underwriters Laboratory Listed in the USA(UL)and Canada(cUL) to support automatic fire sprinkler systems. May be installed into wood using fasteners screws. f . Meets and exceeds the requirements of NFPA 13, ' 13R and 13D. Fig.28M satisfies the UL vertical restraint requirements where needed. ie:, Fig.27B Order By: Figure number and pipe size t (2)Required • Patent#7,744,042 r - fl r - ;.-T i ° �-- �y ° 0 4-� Hanger and Restraint r -' Application :+•_ ° QQ M. Restraint F1g.27B (1)Required f\ __ _ High Side of Hanger ! URestraint Detail A Hanger Application j Pipe Size A Hole Dia.B C Max Spacing* Approx.Wt./100 Part No. in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) lbs. (kg) 28M-3/4 3/4' (20) 2" (50.8) 3/16" (4.8) 35/16" (84.1) 5'-6" (1676) 9 (4.1) 28M-1 1" (25) 21/8' (54.0) 3/16" (4.8) 31/2" (88.9) 6'-0" (1829) 12 (5.4) 28M-11/4 11/4" (32) 25/16" (58.7) 3/16" (4.8) 31/2" (88.9) 6'-6" (1981) 13 (5.9) 28M-11/2 11/2" (49) 27/16" (61.9) 3/16" (4.8) 37/8" (98.4) 7'-0" (2133) 14 (6.3) • 28M-2 2" (50) 25/8" (66.7) 3/16' (4.8) 47/16' (112.7) 8'-0" (2438) 15 (6.8) *Required per NFPA 13 for CPVC plastic pipe All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line Pipe Clamps Fig. 29 - Double Offset Hanger & Restrainer for CPVC Plastic Pipe --- 0 0 c uL us Size Range: Available in 3/4" (20mm)and 1"(25mm)pipe sizes "" " 1.5" LISTED • Material: Pre-Galvanized Steel (38.1mm) Function: Intended to perform as a hanger and restrainer for CPVC, plastic fire sprinkler pipe. Provides double offset 11/2"(20mm)x 11/2"(20mm)from mounting surface.This design will ease installation by eliminating the need for wood block extension and allow retro-fit attachment of hanger to sprinkler pipe. T 1.5" Features: °G. ,t (38.1mm) •Thumb tab provides protection to restrain pipe in rough job site conditions.Tab is not o 0 required to be bent for listed installation. ' o •Offset edge eliminates abrasion. o •Attaches easily to wood structure with two special#10 x 1"hex head self-threading screws furnished with product. o •Can be used as a single offset hanger by aligning "dimples"with top of mounting surface and utilizing two fasteners in two of the three holes provided. Approvals: Underwriters Laboratories Listed in the USA(UL)and Canada(cUL)as a hanger and restrainer to support fire sprinkler systems. Meets and exceeds requirements of NFPA 13, 13R and 13D. Finish: Pre-Galvanized Order By: Figure number and pipe size. Patent Pending 0 et v. a a 1.5" • a€ (38.1mm) 9$ `S 4 i !$i • � „` )relvrl3" 1'S4C.i ,1 1.5, (38.1mm) ® ® ®®� s Double Offset 1 Single Offset Install using a rechargeable electric drill fitted with a 5/16"(7.9mm)socket attachment with the special hex head self-tapping screws provided. Install screws until they bottom out. Pipe can be"snapped"into hanger before or after installation of the screws to the mounting surface. `Thumb tab"may be bent up to provide additional protection to the pipe,but is not • required for performance of the hanger/restrainer function. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. 100 Pipe Clamps Fig. 3184 - Offset Hanger for CPVC Plastic Pipe and IPS Pipe • Size Range: 3/4" (zomm)thru 2" (32mm) Material: Pre-Galvanized Steel C 11S Function: Designed to be used as a hanger for CPVC piping or steel piping LISTED where the"stand-off"design will ease installation by eliminating the need for wood blocking. Pipe Size Features: • Flared edge design protects CPVC pipe from any rough or abrasive surfaces •The "Stand-Off"design eliminates the need for wood block extension •Can be installed on horizontal or vertical piping regardless of mounting surface orientation 2 •Attaches easily to wood structure with two hex head self-threading screws furnished with product ® H •cULus Listed as a hanger for fire sprinkler piping Installation Note: When installed in wood structural members and threads _ from the#10 x 1" screws are exposed, use Fig. 27B speed nut to secure L Approvals: Underwriters Laboratory Listed in the USA(UL)and Canada (cUL)3/4" (20mm)thru 2" (50mm)to support automatic fire sprinkler systems. May be installed into wood using fasteners screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Order By: Figure number and pipe size Patent#7,744,042 -7,---411.7.:4,45n14---,11 -- ; 1--1.!:,,,,.. .yt � p F {e . r�y � t,•1 CPVC L H Max. Hanger Fastener Hex Approx. Pipe Size Overall Overall Spacing Head Size Wt./100 Part No. in. (mm) in. (mm) in. (mm) It. (m) in. (mm) Lbs. (kg) 63184-3/4. 3/4" (20) 29/16' (65.1) 41/4' (107.9) 51/2 (1.67) 5/16 (7.9) 9.0 (4.1) B3184-1 1" U1 213/16" l 1 41/2" Kin 6 Nil 5/16" 7.9 10.0 4.5 '83184-11/4 11/4" (32) 33/16' (81.0) 45/8 (117.5) 61/2 (1.98) 5/16 (7.9) 12.0 UI 83184.1 /z 11/2" 40 37/16 (87.3) 5" (127.0) 7 (2.13) 5/16'1 7.9 12.0 (5.4) 83184-2 :: 2 (50) 37/8' (98.4) 5" (127.0) 8 (2.44) 5/16" (7.9) 15.0 (6.8) • All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. 101 00 COOPER B-Line Product Information MIL,'" • FS-ONE High Performance Intumescent Firestop Sealant Product description •"' !, 1 t ■ Intumescent(expands when exposed to fire)firestop sealant that t si iti hfaifill helps protect combustible and non-combustible penetrations for - , -7 up to 4 hours fire rating , Product features ;, .. ■ Smoke,gas and water resistant after material has cured ) c• • Contains no halogen,solvents or asbestos • High fire rating properties .-. ■ Water based,easy to clean Technical Data FS-ONE ■ Protects most typical firestop penetration applications Chemical basis Water-based intumescent acrylic • Paintable dispersion • Single component systems available Color Red • Meets LEEDTm requirements for indoor environmental quality credit Application temperature 40°F to 104°F(5°C to 40°C) 4.1 Low Emitting Materials,Sealants and Adhesives and 4.2 Paints Skin forming time Approx.20-30 min. and Coatings Curingtime Approx.2 mm/3 days Areas of application Average volume shrinkage 24.1% IISteel,copper and EMT pipes (ASTM C1241) • Insulated steel and co i Movement capability Approx.5% pper p p es Expansion rate(unrestricted) Up to 3-5 times original volume ■ Cable bundles III Closed or vented plastic pipes Temperature resistance(cured) -40°F to 212°F(-40°C to 100°C) II HVAC penetrations Surface burning characteristics Flame Spread:0 (ASTM E 84-96) Smoke Development:5 For use with Sound transmission classification 56(Relates to specific construction) ■ Concrete,masonry,drywall and wood floor assemblies (ASTM E 90-99) • IIWall and floor assemblies rated up to 4 hours Approvals •California State Fire Marshal- No.4485-1200:108 Examples •City of New York-MEA 326-96-M Vol.IV • Sealing around combustible pipe penetrations in fire rated Tested in accordance with construction •UL 1479 •ASTM E 814 •ASTM E 84 MI Sealing around non-combustible penetrations in fire rated 'At 73°F(23°C)and 50% elative humidity construction FO FILL,VOIV OR CAVITY MATERIAL Po FOR USE W EST OVGH-PENETRATION - Be SEE VL FIRE RESISTANCE DIRECTORY 66Y7 APPROVED Installation instructions for FS-ONE Notice 4. Smoothing of firestop sealant:To complete the • On materials where oil,plasticizers or solvents may • Before handling,read Material Safety Data Sheet seal,tool immediately to give a smooth appearance. bleed i.e.impregnated wood,oil based seals,green and product label for safe usage and health Excess sealant,prior to curing,can be cleaned away or partially vulcanized rubber information. from adjacent surfaces and tools with water. • In any penetration other than those specifically • Instructions below are general guidelines—always 5. Leave completed seal undisturbed for 48 tours. described in this manual or the test reports refer to the applicable drawing in the UL Fire 6. For maintenance reasons,a penetration seal could Storage Resistance Directory or Hilti firestop Systems Guide be permanently marked with an identification plate. for complete installation information Store only in fromthe original packagingttempr in a ebetween location In such a case,mark the identification plate and protected moisture at temperatures betw Opening fasten it in a visible position next to the seal. 40°F(5°C)and 86°F(30°C) 1. Clean the opening.Surfaces to which FS-ONE will Not for use • Observe expiration date on the packag be applied should be cleaned of loose debris,dirt, • High movement expansion joints oil,moisture,frost and wax.Structures supporting • Underwater penetrating items must be installed in compliance with local building and electrical standards. Application of firestop sealant 53 ill T - - • „r,+• 2. Install the prescribed backrilling material type and d. rr,,,,�rrr ^ram depth to obtain the desired rating(if required).Leave Q s` - '.) ,- . �'•` gee sufficient depth for applying FS-ONE. 3. Application of firestop sealant:Apply FS-ONE to the f.Clean opening. 2.Pack mineral wool. 3.Apply FS-ONE. 4.Smooth 5.Leave completed 6.Fasten identification required depth in order to obtain the desired fire rating. or required) FS-ONE. se 4e xu Daumshxl»d for pate(d required). . Make sure FS-ONE contacts all surfaces to provide - - - -maximum adhesion.For application of FS-ONE use a 40 standard caullung gun,foil pack gun,bulk loader and a ." ' • / bulk gun.With FS-ONE buckets,Gmco type sealant •°' pumps may be used.(Contact pump manufacturer for a /' proper selection), I Clean opening. 2.Pack mineral wool. 3.Apply FS-ONE. 4.Snrouth 5.Leave completed 6.Fasten identification (It required) FS-ONE. sea undistorted for plate(d moulted). 48 rows. Hilti. Outperform. Outlast. 22 Hilti,Inc.(U.S.)1-800-879-8000•www.us.hiltLcom•en espahol 1-800-879-5000•Hilti Firestop Systems Guide MSDS No.: 259 M,LIT, Revision No.: 010 Revision Date: 08/17/04 ® Page: 1 of 2 MATERIAL SAFETY DATA SHEET • Product name: FS-ONE High Performance Intumescent Firestop Sealant Description: One-part acrylic-based sealant Supplier: Hilti, Inc. P.O. Box 21148,Tulsa,OK 74121 Emergency#(Chem-Trec.): 1 800 424 9300(USA, PR,Virgin Islands,Canada); 001 703 527 3887(other countries) INGREDIENTS AND EXPOSURE LIMITS Ingredients. ; ! ;..: GAS Number; •.PEL;' °., •• '. TLV STEL; Polyacrylate dispersion Mixture NE NE NE Calcium carbonate 001317-65-3 5 mg/m3(T) 10 mg/m3(T) NE Zinc borate 138265-88-0 NE NE NE Ammonium polyphosphate 068333-79-9 NE NE NE Talc 014807-96-6 20 mppcf 2 mg/m3 NE Expandable graphite 012777-87-6 5 mgJm3(T) 2 mg/m3(T) NE Ethylene glycol 000107-21-1 NE C:100 mg/m3(A) NE Polybutene 009003-29-6 NE NE NE Iron oxide 001309-37-1 10 mg/m3 5 mg/m3 NE Glass filament 065997-17-3 NE 5 mgJm3(T) NE Silicon dioxide 014808-60-7 0.05 mg/m3(T) 0.1 mg/m3(T) NE Water 007732-18-5 NE NE NE Abbreviations: PEL = OSHA Permissible Exposure Limit. TLV=ACGIH Threshold Limit Value. C = Ceiling. STEL = Short Term Exposure Limit. NE= None Established. NA=Not Applicable. (T)indicates"as total dust". (R)indicates"as respirable fraction". (A) indicates"as an aerosol". mppcf=million particles per cubic foot. PHYSICAL DATA Appearance: Red paste. Odor: Odorless. • Vapor Density: (air=1) Not determined. Vapor Pressure: 23mbar @ 20C I 68F Boiling Point: Not applicable. VOC Content: 75.0 g/L. Evaporation Rate: Not applicable. Solubility in Water: Soluble. Specific Gravity: 1.5 pH: Not determined. FIRE AND EXPLOSION HAZARD DATA Flash Point: Non-flammable. Flammable Limits: Not applicable. Extinguishing Media: Not applicable. Use extinguishing media as appropriate for surrounding fire. Special Fire Fighting None known. Use a self-contained breathing apparatus when fighting fires involving chemicals. Procedures: Unusual Fire and Explosion None known. Thermal decomposition products can be formed such as oxides of carbon, sulfur Hazards: and phosphorous. REACTIVITY DATA Stability: Stable. Hazardous Polymerization: Will not occur. Incompatibility: Strong acids, peroxides,and oxidizing agents. Decomposition Products: Thermal decomposition can yield CO and CO2. Conditions to Avoid: None known. HEALTH HAZARD DATA Known Hazards: None known. Signs and Symptoms of Possibly irritating upon contact with the eyes or upon repeated contact with the skin. • Exposure: Medical Conditions Eye and skin conditions. Aggravated by Exposure: Routes of Exposure: Dermal. HILT!®is a registered trademark of Hilti Corp. Carcinogenicity: IARC classifies crystalline silica(quartz sand)as Group I based upon evidence among workers in industries where there has been long-term and chronic exposure (via inhalation) to silica dust; e.g. mining, quarry, stone crushing, refractory brick and pottery workers. This product does not pose a dust hazard; therefore, this classification is not relevant. Based upon the nature and • intended use of this product, it does not pose an increased cancer risk to workers. EMERGENCY AND FIRST AID PROCEDURES Eyes: Immediately flush with plenty of water. Call a physician if symptoms occur. Skin: Immediately wipe off material and wash with soap and water. Material can adhere to the skin. If material has adhered to the skin, use an abrasive containing hand cleaner. If material does not come off, buff with a pumice stone. Inhalation: Move victim to fresh air if discomfort develops. Call a physician if symptoms persist. Ingestion: Seek medical attention. Do not induce vomiting unless directed by a physician. If a large quantity was ingested, give 1 to 2 glasses of water to dilute. Never give anything by mouth to an unconscious person. Other: Referral to a physician is recommended if there is any question about the seriousness of the injury/exposure. CONTROL MEASURES AND PERSONAL PROTECTIVE EQUIPMENT Ventilation: General(natural or mechanically induced fresh air movements). Eye Protection: Not required,however, safety glasses should be worn in most industrial settings. Skin Protection: Avoid skin contact.Cloth gloves are suitable for hand protection. Respiratory Protection: None normally required. Where ventilation is inadequate to control vapors, use a NIOSH- approved respirator with organic vapor cartridges. Never enter a confined space without an appropriate air-supplied respirator. PRECAUTIONS FOR SAFE HANDLING AND USE Handling and Storing Store in a cool, dry area preferably between 40°and 77°F. Keep from freezing. Do not store in Precautions: direct sunlight. Avoid contact with the eyes or skin. Practice good hygiene; i.e. always wash thoroughly after handling and before eating or smoking. For industrial use only. Keep out of reach of children. Follow label/use instructions. • Spill Procedures: Immediately wipe away spilled material before it hardens. Place in a container for proper disposal in accordance with all applicable local,state,or federal requirements. REGULATORY INFORMATION Hazard Communication: This MSDS has been prepared in accordance with the federal OSHA Hazard Communication Standard 29 CFR 1910.1200. HMIS Codes: Health 1, Flammability 0, Reactivity 0, PPE B DOT Shipping Name: Not regulated. IATA/ICAO Shipping Name: Not regulated. TSCA Inventory Status: Chemical components listed on TSCA inventory. SARA Title III,Section 313: This product contains < 3% ethylene glycol (CAS 107-21-1) and < 15% zinc borate (re: zinc compounds) which are subject to reporting under Section 313 of SARA Title III (40 CFR Part 372). EPA Waste Code(s): Not regulated by EPA as a hazardous waste. Waste Disposal Methods: Consult with regulatory agencies or your corporate personnel for disposal methods that comply with local, state,and federal safety,health and environmental regulations. CONTACTS Customer Service: 1 800 879 8000 Technical Service: 1 800 879 8000 Health/Safety: 1 800 879 6000 Jerry Metcalf (x6704) Emergency#(Chem-Trec): 1 800 424 9300(USA, PR,Virgin Islands,Canada); 001 703 527 3887(other countries) The information and recommendations contained herein are based upon data believed to be correct; however, no guarantee or warranty of any kind expressed or implied is made with respect to the information provided. • MSDS 259, Page 2 of 2 Certificate of Corn s liance Certificate Number 20100512-R13240 Page 1 of 1 Report Reference 2010 May 12 Issue Date 2010 May 12 Ul Underwriters L Laboratories Inc, Issued to: Hilti, Inc. 54 S 122ND East AVe Tulsa, OK 74146 USA This is to certify that Fill, Void or Cavity Materials representative samples of FS-ONE Have been investigated � • by Underwriters Laboratories Inc. (UL)or any authorized licensee of UL in accordance with the Standard(s)indicated on this Certificate. Standard(s)for Safety: ANSVUL 1479, ANSWL 2079, CAN/ULC-S115-05 Third Edition,revised March 1, 2010 Additional Information: FS-ONE Sealant for use in Joint Systems and FS-ONE for use in Through-Penetration Firestop Systems as currently described in the UL Fire Resistance Directory. Only those products bearing the UL Classification Mark should be considered as being covered by UL's Classification and Follow-Up Service. The UL Classification Mark includes: UL in a circle symbol: KV with the word"CLASSIFIED"(as shown); a control number (may be alphanumeric) assigned by UL; a statement to indicate the extent of UL's evaluation of the product; and, the product category name(product identity)as indicated in the appropriate UL Directory. Look for the UL Classification Mark on the product Is�sued dbby: 7 ReviewednlonG a,Couloute Chris.r ai nson Unclenwriters Laboratories Inc. Undervvriters Laboratories Inc. Any inforination and documentation involving UL>Mark services are provided on behalf of Underwriters Laboratories Inc.It Li or any authorized licensee of UL. ER-5071 ES REPORT' Reissued February 1, 2002 • ICBO Evaluation Service, Inc. • 5360 Workman Mill Road, Whittier, California 90601 • www.icboes.org Filing Category: FIRE-RESISTIVE CONSTRUCTION—Other Fire-resistive Construction HILTI FIRESTOP SYSTEMS FOR THROUGH floors. Two gallons of clean, potable water are added to PENETRATIONS each container and blended using a drill or mechanical mixer.Application temperatures range from 40°F to 110°F HILTI, INC. (4.4°C to 43°C).When stored at temperatures ranging from 5400 SOUTH 122ND EAST AVENUE 40°F to 90°F (4.4°C to 32.2°C) in original unopened TULSA,OKLAHOMA 74146 containers,the shelf life is one year. 2.2.4 CP 618 Firestop Putty Stick:CP 618 Firestop Putty 1.0 SUBJECT Stick,a one-component intumescent firestop p putty, is used Hilti Firestop Systems for Through Penetrations. in the fire-rated through-penetration fire-stop assemblies described in this report.It is a nonhardening reusable putty. 2.0 DESCRIPTION CP 618 is packaged in 18-cubic-inch(294 967 mm3)sticks 2.1 General: and is available in boxes of 12 sticks. The application temperature is 40°F to 95°F(5°C to 35°C). Hilti Firestop Systems are designed to seal through- penetrations in fire-resistive walls and floors.The systems 2.2.5 CP 642/643 Firestop Collars:CP 642/643 Firestop described in Figures 1 through 16 are installed in steel or Collars are zinc-plated sheet steel housings containing wood-framed gypsum wallboard partitions, concrete walls, intumescent inlays.They are packaged complete as single concrete floors and concrete masonry walls.The F-ratings units, with the mounting tabs included. The collars are and T-ratings are noted in these figures,where applicable. designed for plastic pipes used in drain, waste or vented piping systems, including those of acrylonitrile butadiene 2.2 Materials: styrene (ABS), chlorinated polyvinyl chloride (CPVC)and 2.2.1 FS-ONE High Performance Intumescent Firestop flame-retardant polypropylene (FRPP).The CP 642 collar Sealant: FS-ONE is an acrylic-based intumescent sealant is designed for firestopping large combustible pipes[larger that remains flexible after curing and expands when than 4 inches (102 mm)]. The CP 643 collar has a lower • exposed to heat,to impede the passage of flames,smoke profile and utilizes a sheet-metal-collar housing. Firestop and toxic gases. FS-ONE is a one-part, ready-to-use sealant is used in the annular spaces where noted in the sealant that was designed to Firestop insulated and system details. noninsulated metallic pipes,jacketed cables,cable bundles, 2.2.6 CP 680 Cast-In Firestop Device: CP 680 Cast-In and plastic pipes that penetrate concrete, concrete block, Firestop Devices are housings (sleeves) which contain and gypsum or wood fire-resistive construction. FS-ONE is intumescent inlays. The CP 680 device can be used in packaged in 10.1-and 20.2-fluid-ounce(300 and 600 mL) minimum 21/2 inch-thick (63.5 mm) concrete floor slabs. tubes and 5-gallon(19 L)pails.The application temperature With the use of the CP 680 Metal Deck Adapter,the CP 680 range is from 40°F to 100°F(4.4°C to 37.7°C)and the shelf Cast-In Firestop Device may also be used for concrete over life is one year when stored in the unopened original steel deck with a minimum 2'/2-inch(63.5 mm)concrete fill. container at a temperature of 50°F to 100°F (10°C to Permitted penetrating items include metallic and nonmetallic 37.7°C). (i.e.,PVC,CPVC,ABS and FRPP)piping,insulated metallic 2.2.2 FS 657 Fire Block Intumescent Firestop Blocks: piping,and cable bundles. The annular space around cable FS 657 Fire Block is a ready-to-use intumescent or cable bundles must be filled with Hilti CP 618 Firestop firestopping foam block which expands when exposed to Putty Stick. The CP 680 device is limited to use with pipes heat. FS 657 Fireblock is designed to protect large a maximum of 6 inches(152 mm)in diameter. Additional openings with multiple penetrations such as insulated and fill,void or cavity material may be required depending on the noninsulated metallic pipes,cables, cable trays and plastic penetrating item(s). pipes.The blocks may be friction-fitted into the opening and 2.3 Installation: provide fire ratings up to 4 hours. Fireblocks measure 5 inches by 8 inches by 2 inches(127 mm by 203 mm by 51 The through-penetrating item,opening and related surfaces mm)and are available individually or in a case of 26 blocks. must be clean and free of all contaminants that may inhibit curing or adhesion.Each system is installed in accordance 2.2.3 FS 635 Trowelable Firestop Compound: FS 635 with Figures 1 through 28. Trowelable Firestop Compound is a cementitious, dry powder that is mixed with water to produce a pourable or The openings must be included in the opening limitations trowelable material. Packaged in 40-pound (18.1 kg) of Section 302.3 of the UBC for occupancy separations and containers, the material cures to form a rigid, lightweight Section 504.6.2 for area separation walls.Installations must barrier,suitable for firestopping large openings in walls and comply with Section 714 of the UBC. Section 709.6 • 1%REPORTS'-are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed as ���� an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICBO Evaluation Service,Inc.,express or implied, as to any finding or other matter in this report,or as to any product covered by the report. Copyright©2002 Page 1 of 9 Page 2 of 9 ER-5071 describes requirements for penetrations in walls and Underwriters Laboratories Standard 1479; descriptive partitions.Section 710.2 describes particular requirements literature;and installation instructions. • for penetrations in floors, including the need for T-ratings. 4.0 FINDINGS The L rating is the amount of air leakage,in cubic feet per That the Hilti Firestop Systems described in this report minute per square foot of opening (CFM/sq. ft. or feet/minute),through the firestop system at ambient and/or comply with the 1997 Uniform Building Code TPA,subject 400°F (204°C) air temperatures at an air pressure to the following conditions: differential of 0.30 inch in W.C.(74.7 Pa).The L ratings are 4.1 Assemblies are installed in accordance with this intended to assist in determining the suitability of firestop report and manufacturer's instructions. systems for the protection of penetrations and miscellaneous openings in floors and smoke barriers for 4.2 Fire-resistive wall assemblies comply with this smoke control in accordance with Section 905 of the UBC. report and the code. 2.4 Identification: 4.3 Pipe insulation is listed by an approved agency with a flame-spread rating not exceeding 25 and Labels on containers identify the product name, the Hilti, smoke-density rating not exceeding 50. Inc., name and address, expiration date, storage information, batch number and evaluation report number This report is subject to re-examination in one year. (ER-5071). 3.0 EVIDENCE SUBMITTED Reports of tests complying with UBC Standards 7-1 and 7- 5; reports of tests on air leakage, complying with GENERAL NOTES ON FIGURES 1 Assemblies:All fire-resistive assemblies must comply with Chapter 5 Two-Hour Fire-resistive Wood Floor/Chase Wall Assemblies: 7 of the UBC. The minimum dimensions in figures also must be a. Floor: Lumber or plywood subfloor with lumber, plywood, or observed. concrete or gypsum topping finish must comply with Chapter 23 • 2 Concrete and Concrete Masonry Assemblies: The reinforced of the UBC. concrete assemblies are either structural lightweight or normal- ' weight concrete and must comply with Chapter 19 of the UBC. b. Wood Joists:Nominal 2-by-10 or larger lumber joists with 1-by- Reinforced concrete masonry must comply with Chapter 21 of the 3 lumber bridging and fire-blocked ends must comply with UBC. Chapter 23 of the UBC.Joist spacing is 16 inches(456 mm)on center. 3 Gypsum Wallboard and Stud Wall Assemblies: c. Furring Channels:No.25 gage(0.0209-inch)[(0.53 mm)steel a. Steel Studs: Minimum No. 25 gage(0.0209-inch)(0.53 mm), channels,5/8 inch(16 mm)deep by 11/2 inches(38 mm)wide are galvanized steel studs measure at least 21/2 inches (64 mm) fastened to wood joists. Spacing is 24 inches (610 mm) on wide.Allowable spacing is up to 24 inches(610 mm)on center. center. Studs must comply with Chapter 22 of the UBC. d. Gypsum Wallboard:Two layers of 5/8-inch-thick(16 mm)Type b. Wood Studs:Minimum nominal 2-by-4 wood studs must comply X gypsum wallboard ceiling must comply with Chapter 25 of the with Chapter 23 of the UBC.The maximum spacing is 16 inches UBC.The base layer is fastened to the joists and the face layer (406 mm)on center. is fastened to the channels. c. Gypsum Wallboard:Two layers of 5/9 inch-thick(16 mm)Type 6 Chase Wall: X gypsum wallboard are required on each side of the wall a. Wood Studs:Single 2-by-6 or double 2-by-4 wood studs must assembly.The wallboard must comply with Chapter 25 of the comply with Chapter 23 of the UBC.Spacing up to 16 inches UBC. (406 mm)on center is permitted. 4 One-Hour Fire-resistive Wood Floor/Chase Wall Assemblies: b. Sole Plate:Single 2-by-6 or two parallel 2-by-4 lumber plates a. Floor: Lumber or plywood subfloor with lumber, plywood or must comply with Chapter 23 of the UBC. concrete or gypsum topping finish must comply with Chapter 23 c. Top Plate:The double top plate is constructed using either two of the UBC. 2-by-6 lumber plates or two parallel sets of two 2-by-4 lumber b. Wood Joists:Nominal 2-by-10 or larger lumber joists with 1-by- plates complying with Chapter 23 of the UBC. 3 lumber bridging and fire-blocked ends must comply with d. Gypsum Wallboard:One or two layers of5/e inch-thick(16mm) Chapter 23 of the UBC.Joist spacing is 16 inches(406 mm)on Type X gypsum wallboard on each side of the wall must comply center. with Chapter 25 of the UBC. When the double stud wall is c. Gypsum Wallboard:One layer of 5/8-inch-thick(16 mm)Type constructed the penetrating pipe must be surrounded on all four X gypsum wallboard ceiling must comply with Chapter 25 of the sides with the wallboard. UBC.The wallboard is directly attached to wood joists. • Page 3 of 9 ER-5071 Figure 1 F Ire 2 INSF.LATED METAL PIPE tHRELl3-I CONCRETE WALL UR BLOCK VAIL SINGLE OR MULTIPLE CABLES THROUGH• F RATING=2-ER CONCRETE WALL ER BLOCK WALL T RAMC•l-NR. F DATING=3-NR 0 In, ,:..::......:....„.„... ,...,.... L RA1DL AT AIIHIE T-4 MM.FT. T RATING=B.HR L R4TD$Al WIT=LESS TENN 1 DIVA,FT. SECfl A,A FOE y` �— 1111 q A A A .' j r 4 I.WNETETE WALL AAEE]41Y I3-01 FIFE-2AT1NG1 A UO(FRVED3TT CO NDFWL WEIGHT CINCIEIE WALL WA 3'THDIK1 L CTNCREIE WALL ASO:ELY(24R F]RE-RATIN& a CONCRETE BLOC(WALL A LIENIVED3fT ER HOWL WEIGHT CONCRETE WALL 6A@lH1N 4-12'THICK 2 EPTDNAU NAYDLN 6'FI}NINAL IIMETER STEEL PIPE SLEEVE(SUEHLLE l0 ER D CONCRETE BLOCK WALL HEAVERS. a OPTIONAL NAKIW.N 20'NCFIBNL METER STEEL PIPE SLEEVE C'1CFEDIILE 10 IR HEAVED. a MYNA 4'DIMETER CAME BUGLE TD BE A CI31HD84TlON EF ANY BF 1HE FTLLINDIG! a PENEEPATOG ITEM TO HE OW OF TM FRLBWDYn A WWII 3O0 PAIR FE 24 JAE TE].EPHEFE CANE WIH PVC JACKET. A NAME 12'FOJNAL 1DANETER STEEL FIFE CICHEILLE ID OR FEAVEFCA a R']NJN EGG KCNIL PRYER CAILE WLM PVC JACKET. a W.YHJN 6'MIH1N L➢LANETEA PIPER PIPE. C 141151.111 7/C Ma 12 AVG RIMER CABLE VIH PVC JACKET. 4.IU4.2'THICK FILLIM'CYLINDRICIL HEAVY 11LITY 4911 35 PER)GLASS FIRER UNITS WITH A WNCOUN(24 FEBEPJ 1/2'METER FIBER-[PM CABLE ALL SERVICE JACKET ffffE RUST BE COVERED VEIN M6MJLATIIN TWIJJGIXDJT ITS LENGTHS. E WIDEN 3/C In l2 AVG IETAL-CLAD CAB.. S EEO 4' THENIESS HINER1L 4IDL OCR 4 PCF IQLSRY1 T][3(TLY PACKED 4.HINIH.N l-V2'TFEEIDJEOE HINEW+L 4TIL(N]N.4 FtF ODIUTYI THINLY FAMED 6 KINIEtH L/2'DEPTH FOOT FS-DE]NTLFESCENT nRcnOP SEALANT, S FONIHJJ V2'BEPTH ELM FS-0E ENTLF[SCDTT FIRESIDE SLALOM. NOTES 1 L WOO DIMETER OF°FINING=6'. !ETES 1 1.NIXIIIUI DIAMETER(I➢PENPG= NC a CABLES TO FILL NAM 2T4,TO HA]BI4.H 45E OF CROSS-SECTIQYL AREA EF E.ANNAAR SPACE=HIHIHLH VC',W IDttI E1/4'. IPENING. 3.RCMP 112'DEPTH Na11 FS-BEE 1NTBFESCEHF FRESTIF SEALANT IS REEEGREII a KINDARN 1/2'DEPTH HILT[ FS-WE INI1.NESE2IT FIPESTCP SEN.ANT IS REALM • ON KITH SIRES IF VAIL EN BOTH SEES IF WALL FMETAL PIPE THROUGH A SLEEVE�IN4CONCRETE WALL OR BLEICK WALL PLASTIC PIPE THROUGH 3 C CRETE WALL OR BLOCK 4JFLL F RATING=3-14E. F RATING=141k I RATING=B-NR. I RAW=HE. L ROSE Al ANOINT=LESS 1ILUN I CFX/SD]FT. L RATING AT 490'F=4 CFH/113.FT. FINNY VIEW SECTEN AA FRONT VIEW SECT]EN A-A 0 T p p A( ! Q A , ,'.' A r :o. Y < 114. I L WIEYETE VALL AS&]M C44R FOIE•AIT➢G. A LNNlVE]HIT IR N11042 VFDOfr C¢IEPETE V1LL AWN 4-1/2'THKK1 B.CONCRETE BLOCK WAIL A.PEKIRATBL INN 1¢BE BIC IF TIE r0J.OW]L VLW SEE NINE w,2 NM. 1,CE6CRETE WALL ASLONBLY C4-611 FIFE-HATME} k WNW 6'N64YL METER PVC FLUTE FIFE cum*AND 0310 EEC. A LD304E1EH1 CR AORNAL 1.ECG{1 CONCRETE'HALL(XIN.4-12'TWO. a F05111 6'MORE METER ADS PLASM PIPE ALIJI.LAR N B SOLID B.CONCRETE BLOCK WALL C I4AI211 6'NB M'L INIETER FWP ftATTIC ONE. 2.�WWXIJH 32'FII@NL D]AFf1ER STEELPIPE SLEEVE 6CIEIL E 40 ER ¢F110AMM 6'HBDYL DN4NErfR CPvC<PM F PDE FEAVIERI 3.HUIC]N E R N Fan FT-0E IE TBESCELL R CIE SEAIFAT. N.Fan CP 6N2Ik Dan CP G43 ROtFSRP CELLAR f4E TOILE MM. 3.P0ETRA1M4 OEM TO PE RE OF TIE FTILBVNIO. I.MAINE ma FBR Han CP 64E IR HLTI Er 613 FTI1:STIP WILN+ A HA%MON 30'FO@NL IVEFIER STEEL PIPE CECIEDI.LE W ER IEAV]ER1 6.I41TI F4JNR ACTUATED FAS1EIERS C-2F 27 PBD VEIN VASN3m OP VI'Ian B HAXDBN 6'GOAL DIAIET[R KIPPER PIPE. ENIK-EaT B NCIa;III FASTEN MR NOWISE TAM. C HANNON 6'MEAL MAIUTER STEEL MOLE FIFE ILNEER II FECIDET IESLFOPTINN II NI IF OHM TADS I NA%WEE SE A HARM 4'NOMINAL DMIETER UT 4.19NOIAR 1-2/4'119021ESS HDERAL YELL Or14 4 PCF DFNSIFAS T11A9LY PACKED. L-VE W 613 W1d' E E'16W 5.19NI1CUN I/4'DEPTH TILT]FS-0E]Naif(CENT F]RESTEP SEALANT. P Cr 613 630E' a E511' 6.HINIHON ITT CROWN FILTI FS-ENE INTUNEOTINT nta RIP SEALANT APPLED AT POINT CF r CP 612 W/B' 2 4' 411 CURTACT. !' Cr 614 NAVE 2 5' 6' CP 642 1NVY 6 7NOTES 1 L NAOLHUR DIAFETER CF OPENING=3E'. 2 ANNULAR SPACE=I9NBUN D',NA3N1N 1-718', ICIES 11 MLR CP 642/642 FTESTIP MARS ARE FEI]1BE]I1 SNP MIS OF WU AMPLY. 3 NIBLN V4'DEPTH HELTI FE-IRE INTJEZCFNT FBRESTIP SEVIN IS a MNBLAR!PACE=MUM IP,MOW 1/2E REQUIRED IN 81TH STIES(F VNl.ASSENILY. F a➢a]IR 1111110 PIPING SYSTEM ova.881.FFBP=971EIUI Al.ffvt=SOR]7A Page 4 of 9 ER-5071 Figure 5 Figure 6 INSULATED METAL PIPE THRDJFU-II-HR OR 2-If, WOO FLOOR ASSEMBLY CABLE/CARLE BUNDLE THROUGH 1-HR. ER 2-HR. V00B FLOUR ASSEMBLY F RATING=1-HP.IR 2-HP, L RATING AT AHEM=4 CFH/SO,FL F RATING=14R. BR 2-14t • T RATING=1-14R ER 2-1IR L RAMC AT OPT=LEE THIN 1 CFXVSD.FT. T RATING=0,1,RR 2-Ht N'VIEW SECTION TIP vmv 3EL'IQI A-A 0 TI rli IIr� II Ft FAI p A II �., III„ ir't. rt,.,,1 i _________.--____ __,,, 3--- ______-_-7-__:. Fel i ►1 Iii - N 1 - II1 1'1II At � '"' ° A ° IVA ►1iu o Ilf 11110 a a IZ 1.WOOD FLOORICEILING ASSEMBLY(1-HR OR 2-HR FIRE-RATING)(241R SHOWN). 2,LLHOER IR FLY'L®SLEFLOUR WITH FINISH FUIR OF LUBBER,PLYVTI®,OR FL[[R I.WOOD FLOORICEIUNG ASSEMBLY 1 HR OR 2-HR FIRE-RATING) 2 HR SHOWN). TOPPING MORE (- 1- 3 TOP PLATE 2.LINER ER FLYVOID SUBFLOOR WITH FINISH FLEUR OF LLIOFR,PLTWOID,OR FUER 4.GYPSUH WILL ASSEMBLY O4R IR 2-HP FIRE-RATTN6(2-HR SHINS, TOPPING MIXTURE S PENETRATING 1TEN TO DE ONE IT ILE FOLLOWUH S TAP PLATE (NOTE FLOOR POEFRATDNS HOST BE GIATAOED ARO LOCATED WITHIN TIE CAVITY OF A WALLS, 4,GYPSUM WILL ASHY QHER ER 2-HR FIRE-RATKO(2-HR SF4VN). A HAYINLH 2'MI-IB HL➢TAIWTER STEEL PIPE IIHEILLE IC IR FEAVIERL S NA%DUN 2' O1AHETER CABLE BUNDLE HAY CDNSLSI OF MA'(F THE IULff I GI B HWINLH 2'OEM_MEIER COPPER PIPE (NOTE FLOOR FE}ETRATD}!S NEST BE WADED AHD LLCATED VIGOR TIE CAVITY OF A VALLI. C NanULM 2'WHORL AIAWETER STEEL=TUT, A RG 59 CUIXIAL CARE. D NWTIILN 2'H}@4LL 1]1+[IER ENT. a 10311.14 SIC NI.22 AVG TELETHINE CABLE 6.PIPE INSLLATD TO BE[GE OF THE F[LLUVLNGI C WON 2/C NIL 12 AWG CARE A L/2'IBSLOV CSLRIIRICAL HEAVY TENSITY 6'O11 35 PCF)CIASS It Wei SIC(+GONE)2/D AWG SET CABLE RALMO&II OR CIFPEFS F(OER UNITS WIIH ALL SERVICE.140(ET E 15W1411 3/C NO 10 AVE CABLE(Rolm) 3 I/4'THEE AR/PVC FLE}OOLE FIRM DLSLLAT@l. F. WOMEN 3rC NE.12 FETAL CLAD CABLE 6TR USE IN L-HR RATED ASSUMES ONLY). IUD FIFE RUST IE COVERED VETH INSULATION TFFAIBUUT OS 11NG1H d.NDOMA1 214'IEPTN SALT]FSdE DIDIESCEHT FIRESTIP SEALANT, 7.NI NDIM 3/4'DEPTH HILTE FS-0E DM1ESCENT FRUIT SEALANT, 7.PROVIDE A LE}EROUS TM CF ND_IE FS-ONE 1NT1L£9CE}(T FOIESTOP SEALANT FLUSH S PROVIDE h GE}ERAUS SAD OF HLTI FS-ONE INIBIESCFNT FOIESIOP SEALWIT FLUSH VON TIE KITTEN IF DE TOP PLATE WIN THE AOF1iN CF THE TO,PLATE. NOES 1 1.1440111 DLNETER EF(€}ID1G FOR LiIR UR 2-IR RATED ASHY IS 2-I/2'IR 2' FEES 1 1.IALMI111 METER EF CUM=4'. RESPECTIVELY, 2.AFNAAR SPACE=1/7 BUN ELM FIBER PIPE IHSUTAT@J IS USED, P.AIRLAR SPACE KIVEEN CAKE BUNDLE AID(FENDE=H]NO41N 0',WWI 1/2'. XIXOUN LW,HASOUR 3/3'V-EN AO/PVC PU'E DGLLATE71 ES USES. 3 CAKES TO FILL A NAIGHLN 4S OF CROSS-5ECfl YL AREA IF[FEHING • FI ure 7 FigLre 8 FETAL PIPE THROUGH 1-IR. OR 2-HR VUOD FLOOR ASSEMBLY PLASTIC PIPE THROUGH 1-HR OR 2-HR. WOOD FLIER ASSEMBLY F RATING=1-lit OR 2-FR L RATING AT ANAENT=LESS THAN L CFN/SA FT. F RUNG•1446 AND 2-1N.MN/TO PATOIS IT FLIER A48OR_Y) T RATING=1-1R OR 2-FR L RATIO AT 410'F=4 CUM.FT. T RAIDIG-E+L. L RATIN AT NSEIEW=LEHI TVA 1 CFHSO FT. TOP VIEV SECT1EN A-A L RATOI6 AT UN'F=4 CRWOCL FT, r ,I IURTUTVI PA A-A el U E�� 0!t3 4 ,://,-1, �II • •.}}� i P 4) w q:14ilI AA � 1 .S OFF. 0 I dig '// 11 _.11 �I f 0 III 1.WOOD FLOORICFJUNG ASSEMBLY(1-1-IR FIRE-RATED FLOOR SHOWN).p 4Q 2.LUNHER IR HY6MED SLUFLER VEIN F1XCSi FLOOR OF DIVER,FLYVIIR,OR F13HE TIPPAG POSTURE 3.MP RATE 4.6YPSIH VAIL ASSEILLY S-If OR 2-FR FIRE-RATIO CI-NB SHAM 5.PENEBRATDI LIEN TO a DE IF RE FILMING(LSO SEE FUZE Ill 2 BLOW CLAD FLEER PEHETRATIBS MUST IE COMM AMID LCCATEO VETHIN THE CAVITY EF A VALLI 1.WOOD FLOOFWCEIUNG ASSEMBLY(1-HR OR 2-HR FIRE-RATING)(2-HR SHOWN). A N14YDRN 4'FBOX(L DIAXETER PVC PLASTIC PIPE(CO III AT[R SOLD)CUDi7. B H41014I11 4'H}9N(L IEANETER ABS PLASTIC FIFE MOLL N?UR SEED CORES 2.URGER ER PLYVTID SUOEEIM WITH FINISH FLOOR EF UMBER,PITI000 ER FUER C.MOM 4'Fi}OX(L IUANETER TRIP MASTIC PIPE. UP1146 INDOLIRE. D.14004111 4'MEWL IDANETEP CFVC PLASTIC FIFE 3 TIP FLAILd.AMEN 3/4'IEDTN N F4�D_T7 E INTEMEEPIT 17RESTIP SEALANT. 4 MIN WAIL ASSFJIOLY tl-HR CR 2�R FTN:-RATINGS(2-HR RCM 7.AMA L/ 'DEMI HRTE FS-fE NR.FESCENI TRAMP SEALANT FLUSH WITH AATIDI SLFEACE[F TOP RATE S M}ETRATING ITLTI TO RE RE SF TIE FOLLIIVRO I.HMI CP 643 FIRESIDE=AR(S[E TAKE KIR"). (MITES,FLOOR PLNETRA170XS OUST BE CINTAIED MI LOCATED VI}ON TLE CAVITY OF A VALL7 9.V®SCREWS VON VANERS GEM RE USED TO FASTER EACH 111NTNG TAB EF FR W COLLAR, A N4MONUN 4'MIMIC DIAIETER STEEL FIFE(SCHEILTE 10 ER HEAVER). B WO 4'MOM.IAAIETER CIPHB PIPE HIM FIFE NIA FR®IOT IESEPRION III IT FUNTML TAM NAY HIE SEE C WNW 4'NUNALIL DOAIETFR ITE L CONDOM L-1/2' CP 4125E415' 2 2-1P2' B NAAUNUN 4'}IHBL'L DDAIEIER 61F. r EP/43 GAR' 2 2-113' 6 NDIHUH 3/4'OEPTH FOLTE FS-EDE INIIJEAINF FIIFST 'SEALANT[R FS 601 r ci 649 gas- g r E]ASREIUS C D II HI'SEAL-NT. F CP d4A 1111Y 3 Y • 1.�G ffA0 OF COLT]FS-0E 1X1l1ESCE}lF FUE.SIU"SEALANT CR FS 6(D ELASTQERID FIRESTIP SU LAM-FLUSH VLTH FUTON SURFACE CF TIP PLATE MITES]L A}NLAR SPACE=191114.11 0',HASU1-H 1/4', P.CLOSED ER 444T10 PINS SY5TOIG CP41C,AA$,FRPP-SCHEDULE 441,(PVC-SIR 17P MITE 1 L RAfINUN DIA1f'LF([F OPEFING =5', a AS AN ALTERNATE TO HUE CP 643 FPEST[P CELLAR.SDI HAY USE A HILT) 2.AGELAR SPACE=HEM 1/B', MOAN 3/4', FETAND4 COLLAR CDFLETELY FILLED VITH POUT FS-GE INIUESCf T FRESTE SEALANT, Page 5 of 9 ER-5071 F'ppure 9 Figure 10 INSULATED METAL PIPE THROUGH 1-HR. GYPSUM WALL ASSEMBLY CABLE BLFITLE THROUGH l-HR, CR 2-HR. GIPSUM VALL ASSEMBLY • F RATING=l-FR F PAINS RATINGN =1-FR ER 2-fk L RATING Al ANBDHT=5 CFIVSA FT. T RATING= LIE T RAT = -R L RATING AT 40N'F=2 CFWSO,FT. L RATING AT H4B1ENT=4 LFH/S11 FT. L RATTNG AT MIFF=LESS THAN 1 CFNVSO FT. MR VIEW Hal =MI A-A SEMENA"T 0 A / IIUII ° 0 i 5 y• /4 ". ), 2 - - 0 11111 0 f HADDIUN EN' '� 3 5 1.GYPSUM WALLASSEMBLY(I-HR OR 2-FIR FIRE-RATING)(2-HR SHOWN). 2.WTIINYL NAYINLH 4'MAX L DLVETER STEEL PIPE SLEEVE(SUEDLLE 5 OR A-1 TINE (SEE TNI1E NO.4 IELI'A, 3,CANE RUNDLE TA CONSIST OF me IF THE FRLOA'TNG A MASO4JN 7/C PEW AVG CARE. B.HA%RUN 25 PAIR IE 24 TEIIPIUIE CARE C R6 59 CENQM-CARE. A 3/C NIL 14 AVG IETLL-CLAN CARE E 2/C NO B AVG FETAL-CLAD CANE. I.GYPSUM WALLASSEMBLY(1-HR FIRE-RATING). F.HA%BUN 5/B'MAKER FlBERiP70C CABLE. 4,HLTI IS-GE AEILFEECENT FIRESTEP SEALANT. a PENETRATING ITCH TA R ME LF TIE FALLOWING• A HBlB41 5/11'DEPTH,FIR A 14R FEE-RATING. A HAIONLN 1N'METAL IFAT£IER STEEL PIPE<SCH:EL E IB CH WAVIER% A MDDHDI 1-1/4'RPTN,FOR A 24R FIFE-RATING A 164011111 6'MHNNL DWf7ER COFFER PIPE 3.SEE LUTE NEL 4 BELOW. C MINIM 4'I8@N-DLAW1ER STEEL CENTUIT. - A HAIUNLH 4'MJOTA1 DWEIER ENT. IVIES.1.MAYDLH URETER IF FFENUIG=4'. 3 PAS.2' LINER/ELLN CILIFERICAL FEAVf LEWITY NIL 35 PO(i.ASS PIER UNITS WITH S.CARES TO FILL WORN 331 OF CROSS-SCI.NLNML.AREA CT Man FLL SERVER JVACEET(ME RUST IC CGWDED VRN muumuu T}FUJBUUT RS LETGTIO. 3.FIRM SPACE=HAM 1/4',MLi@tlI 3/4'. 4.1.01.01-H 5/8'IEPTH HLTI FS-LIE INR4ESCENT FIREETEP SEALANT, 4.STEEL SLEEVE M4Y BE FLASH VITH WALL SURFACE ER MEMO LP 10 LW IEtUID 5 H1LN141 12'CROWN HILT) FS-TIE DITIM SCENT FIRESTE SEALANT AT PONT IT CIINTAET. VAIL SURFACE.WHEN SLEEVE TS FLUSH WITH VALL,?RFD'NLLTL FSAME NOTES,L XAl]NUN NATTER[F OPENING-1d'. 1NRfESCENT FIRESTEP SEALANT ENID WALL SUFFICE.WHEN SLEEVE IS E]CIENBED NEMVIU ONE IR RTTH SITES BF WALL,APPLY lir MIN NMI FS-ONE • a AlfLL/R SPACE=HINIALII O'.H.4Y0411 1.-7/11'. DOLFEFCEXT FIRESTTP SEALANT TO WALL/SLEEVE INTERFACEEl urB II Flgure 12 METAL PIPE THROUGH 1412, OR 2-HR GYPSUM WALL ASSEMBLY PLASTIC PIPE THROUGH 1-11R. OR E-HR, GYPSUM WALL ASSEMBLY F TAME=N(OR 2-If6 F 6AT1I6'HR W C-NS T RIME=0-AR. T RATIN6.HE IF NE L RATING AT OPULENT-LESS TMYI 1 a'N/ER.FT. L RATING AT 400F=LESS THAN 4 CFWEI.FT FOIE VIE/ SECTION A-A T FEINT VIEW TA-A A A L +7 r / 3 Ito III 0 11 o„ 1 P AY %kk ..i•' 0. IIII o 0 ,,..II II A.1I. / A FA 4 1 GYPSUM WALL ASSEMBLY(1-HR OR 2-HR FIRE-RATING)(2-HR SHOWN). E.PElETRATING ITU TO IE EIE IP ME FELLBVDIG ME MITE NB 9 MINN A IROAII 6'MOW BTAKTEI NC RAMC PIPE MIME ULAR IR ono m112 IL N5%B6.41 6'BOWL BRPETEI AR RAMC FI'E(CEILBAR IR SOLID Owl C.NVDIP.N 6'RM.METER MP BASTE PIPE. A 1204.11 6'NINIIPL DIKTER WYE PLASTIC FIRE 1.GYPSUM WALL ASSEMBLY(I-FIR OR 2-FIR FIRE-RATING)(2-FIR SHOWN). 3 SEE NUTS Ill EERY. 2 PEMETRAANG]TEN FN DE ONE IT 7FE FOLLOWING 4.ALTO CP Al2 IR ALTO CP dAI MOTIF COLUUR MI TARE BEERS. 5 FASTEN FA01 IOHUG TAR IB VALL ASSURLY VEM IOLTI WA TIFUFR FIT. A F4WM-H 30'MINNIAL DIANETER STEEL PIPE(SCHEDULE 10 ER HEAVIERI, A WOO 6'141412L METER COFFER FIFE PPE IMIEUD PFIKET DESSITFTON 111r HIRERS TAW )B74 TEE 817E C.WORN 6'OWL DWEIER STEEL OMIII. 1-112, CP 6.13 S1/15' 2 2-1/R• A FHUFLH 4'IU4IWL DEMETER ENT. t' CP 643 63,V t 2-5B' 3 HA.TI FS-0NE NTTUNFSEENT FIRES-HIP SEALNEL 3. HS yvy. 9 4. A HNUIUN 5/E'DEPTH,FAR A I-HR FIRE-RATING 4' CP 649 UN' 9 5' A HINHUN l-V4'IEPTH,FIAT A 2-HR FIRE-RATINE. 6' CP Al2 1FAVd' d 7' • 4.NNUMN 12'DEAD HD_TE FS-ONE 1NTLFESEBIT FUTFSTO' Mg 4ITT AT POINT W CUTTACT. KITES,1.HLUIIPI DLUETER OF[MONO PEELL To NEE CBJI ME,RIMEUY DEPTH MILTT fS`OIE ONUE9CEXT F'FBCTO'SEALANT A 32-l/4' FOR STEEL STUD WALLS. IN NNRIAS IACE ARM PLASTIC PIPE, A 14-1/2'FIR VIA STUD VALLS a MAAAR VALE.NININH P.IW%DRII 1/2'. 2 ANNU}R SPACE 4 HEM 0',MGM 2-1/4', 3[LASED(R LENTEO PRE SYSTPN1 CABS.PVC.ROW=ICTEDLE AL EPA'G SIR LT). Page 6 of 9 ER-5071 Figure 13 Figure 14 NULT]PLE METAL PIPES THEOUGH CONCRETE WALL MR BLOCK WALL HLLTlftE PENETRATING]TENS THROUGH COPERETE VALL IR BLT]CK WILL • F RATING=3-0-R T RATDDE-0-R L PATER AT 41FFF E VW58 Fri• T RATING=0-HR. FWD VEYPRINT VEEP SECT �A SECIWX A-A Dli8 � ' DaP,gr L• NIA fI mem CAINoht i l %5I/.'7L/fII/I6 �': �. O l3 WNW 3'P' a •r, 1 L ctN IE VALL ASHENRY R3-HR FIRE-RATOh ; .. r.- A A.L0311WD31F OR IQM2L HEIE 1 CRCBEEE WAL OM 4-12'WEE y� B.CONCRETE BLOCK WALL - �' @ 2 MOM 19'x E'ALUMNI'ER STEEL OPEN LAMER CARE TPAY, a �_: fir:.: .- ?Z 3.kW CONDONATION CF TFE FILENAME CARES PAT BE USED WITION THE CABLE TRAY 'cT�'. �'g.58f. ...$w e' :-ram• SEE NOTE NO.41EL045 b A . A.TIC Nl 12 AVM ETPPEH COHOLCT132 CARE. B NAY.350 ICAO.WITH LIE XIJLATON Alm JACKET. C.NAB,NO PAIR NO,24 AYE TELEPFR[CABLE. O.24 F[RR--CF]]E CARE TRAY. 1R' METED. L PENETRATING [TEENS TO HE ANY EF TIE FOLL04I6 Mee 6'MEWL DIAMETER STEEL POI OR CiTE..CC WXU ER NWONIF 4'NONOHPL IW %.(LH COPPER POPE ER ENT. S NAIL 1-112' TH[Clf HMV CANONICAL IEAVY ID]JS]TY ANX,35 P(T)GLASS FIRER LAMS VIA L CEFETETE VALE ASSENHtY T3-1R FIFE-PAULA ALL SWIM JACKET RIPE HOST LIMPED TNROOLIOJT ITT LEN;11A A.LORITYEIGHT ER NORMAL WED3YT CONCFETE VALL MIN.4-1/2'MUM. 2" CAME DJN[LE T-0 HE A CT!$]NA11]4 IF ANY IF lYE FU I O IK B.CONCRETE BLOCK WALL A.7/C NO.12 AVE CARE WIEN PVC JACEET. D 32C NO.8 ALC ORN CLAD CARE V[IH APE 2.FNAmEPF 12'FL}@NL DBVETER STEEL PIPE(5'C}EU.LE IA OR WAVED. H.25 PAR III 24 AVG TELEPHONE CARE U6LLAT]ON AND PVC JACKET. C,PANES rvc NI ID 4001 ERG 62A(00.11L CABLE, 3.10301 4'MHI WL OVHEIER C]PFER PEE, STEEL CIFIDIA'T,ER ENT. F.24 FTRR-OPTIC CAKE 1110,v2'IAI 4.Fffd@1G Nil SNEMf1 USE A RIM 1114R10 MATERIAL TEl SLPPORT TILT]FS E.M 7.KITE FS 657 FOIE ROCK I'THICK x 9 VIDE x 8'DEEP,REF.RP V1EV1. TFNT.ET_AOLE FIRESTCP CONFORM MONS ITS INITIAL CORE UON.24 HORSt. 5.0010 2-12' IEPTH KATI FS 635 TROAELABLE FIRw11F C(HPOOHD NOTES t L WIIHJN AREA Cr FEll0A .1296 SOME IDlIET VITA Me EGOISM OF 36 ACHES a AMNIA SPACE FOR CABLE TRAY.NOIMIN 1-L/2,NAXRIN 4-12', a ANNAI SPACE FOR FIFE AND CANE PEFETRATIOOS=F-0NOUH 1',HATIIH 4-12', NOTES•I NNM.H CLEAAVCE BETVEEH FIFES, OR BETWEEN PIPES AHD PERIFFERT 4.PASI17N IKEA IT CARES EBWLS SOS II CRIBS-SfCTIDWL AIFA OF CAKE TBAY. IF OPENING=1'. S APPLY NOT[ES-0E OBOIESCEHT FIRES1EP RAANT 114ID OHE4ILtA IF CANES, 2 NA)]HUM AREA IF OPETMNG=784 SQUARE SACKS YOH NASINUN INNENSION LE IEREEN CARES am CARE TRAY,NIB ANY VIES TR HIYNII INTENT PISMIRE 29 ACHES. 6 WIRE NSR 043T 4{f.TA HEN RE ANLLAR SPACE ENYEIDS 4-1/2',A IOONAL 2 1N.SO.NB III S'G WISE MESH SHILL ff LSD KEEP TFE FEU FS 617 FIRE 11L7 ]X R 6 ACE CABLE BUNDLE TEFI]U0- 1-HR R 211R, GYPSUM WALL ASSEMBLY CABLE BLN➢LE THI�UGH Flare RH CONCRETE WALL ASSEMBLY F RAISE=1-712.ER 2-fR, F RAMC=2-HA. T RATDG=0-FR T RATING=0-FR FFEWI VIEV SECTION A-A MIT VIEW A-A A reb-A /// II III •��L.. IH ��• a L�q h3 111 UII 19 I� L-b A I.CONCRETE ROCK VC_ASSENRY 2-FR FREiATOTGY, 1.GYPSUM WALL ASSEMBLY(1-HR OR2-HR FIRE-RATING)(2-HR SHOWN). A LIGHTWEIGHT OR NRHAL'1SNT [COMPETE VALI 2NIHBHLH 3'THDDT0. 2.HA 3704 4'M]IDML DDVETER STEEL PIPE SLEEVE ESCIEOUE 5 IR THINFR) B.CO4' BA BLOCK WALL 2(ALSO S 4' BANAL 4 HEI7'ER STEEL PIPE SLEEVE aCHEILIE 5 ER SEATERS GWBL SEE s NI 4MOF (ALSO SEE LE1E NO.C4 HE?EF 3.CABLE OLPIRE TO CEISIPT OF ANY OF TIE FRLOYDG 3 CARE BUGLE TO WRITE?ff ANY OF THE FO.LOWI3461 A.RG 59 CIWOAL CARE. A RG 53 CII4YBHL CABLE B.HA)014H 6 PAIR HO 24 AVG TELEPHONE CARE B.1*10tH 6 PAR NI AVG TELEPHIDE CARE. C.24 TT1FR-EPTIC CARE MAX.1/4•DGYETEFO. C 24 FIRR-lYlE CARE EFHAA 1/4'DDAHETERA O,ROFE]R 221E NI DI*ERNOA, It ROE1C,VC NE N+RXIA. E.HA)0NH 3/C III 12 AWG CARE IN A NON I/2'FLEXIBLE METAL MIT. E HUOItK 3/C NO 12 416 CABLE DJ A LEK 12'FLEYIRE NETAL OMIT. 4.MOlIKml 5/0' ITPTH 11D_TI CP 610("CHASTE'POTTY STICK WITH A1007/E HAL 114' 4. 111811.11 5/8' IEPTH FOLIO CP 618 FIRE5NP PUTTY STOCK WITH ADDCTO]NAL 1/4' CROVN AMINO CARES(ALSO SEE NOTE NO,3 BELJ A CRQ.'N ARO RO CARES[ALSO SEE NOTE NEL 3 BELDWi. KITES,I.XpiON.N MAKIER ff OPINING-4-U!'. NOTES,L WHIN INKIER ff EffNOIG=4-L12'. 2.CABLES TO FILL A AVM25'L CF E1ASS-SECTLDIAL AREA OF INNING 3. CARES TO 8 FI A HA)ONDF 251 OF LTd1SS-SECTIE AREA ff OPENING • 3,H ILTE CP 619 FERESNP KITTY STOCK TO BE FORCED INTO DESHITICES 3.HILT](P 61B FiRETTOP PUTTY STICK El BE FIRED UM INTERSTICES EF CARES TO HOORN CLIENT POSSIBLE OF CARES TO HA)0F1H EXTENT MULE 4.WHEN USING STEEL SLEEVE,APPLY FOLTf CP 612 POTTY STICK OHM ONE VEEN MPG A STEEL SLEEVE,APPLY FRS[CP 618 PUTY STICK QIE WALL SURFACE aPPLETELY CIIvERDE SLEEVE VALL SLIFACE COWLETELY CD/ENING SLEEVE. 5.MLR SPACE FUR CABLE BUNDLE' loom LID',WOW 3/4'. 5.ANNUM SPACE FIR CARE BLNOLE=NIMItH I/O',145.13141N 3/4', Page 7 of 9 ER-5071 • Flgire 17 f1 ore iB BLANK OPENING THROUGH CONCRETE FLOOR OR CONCRETE BLANK OPENING THROUGH CRICRETE FLOOR OR CONCRETE OVER METAL DECKING OVER METAL DECKING F-RATAU=2-Fit F-RATING=3-HR. T-RATING=1-HR. T-RATING=2-FR.MD 3-FR' 10P VIEW IC'VIEW A A SECTION A-A SECIIOI A-A / ., ,� %� 7% ' �I��IIB . l • • y6i �uPIiPiiV 4, Q .1 ¢ 0 A A J L CONCRETE FLOOR ASSEMBLY(2-O.FIRE-RATING) L CONCRETE FLED ASSEMBLY 0-11R.FIRE-RATING). A.UGHWEIGHT OR FORMAL WEIGHT COCRETE FLOOR(NX 2-1/2'THICK). A LIFI(TWEIGHT OR?ORAL VEIFHT CINCRETE FLIER oft 4-1/2'THICKX I.STEEL FLOM UNIT/FLOOR ASSEMBLY-IQWWY VEIGHT CONCRETE FLIER(MIN 2-1/2' L STEEL FLOOR MIT/FLOOR ASSEMBLY-MRMAL WUGHT COCRETE FUER(Mix 4-1/2' THICK)(OVER METAL DECKING THICK)OVER METAL DECKING 2.FBLTI CP 6130 CAST-IN FRESTOP DEVICE(25',4',CR 6') CAST OR GROUTED INTO ESACRENE 2.HILT{CP 680 CAST-IN FIRESTIP IEVICE(25',4',1R 6'),CAST ER GROUTED INTO CONCRETE FLOM FLOOR. 3 MINIMUM 1'DEPTH HILTI CP 618 FIRESTIP PUTTY STICK(FLUSH WITH TOP SURFACE(F DEVICE). 1 MINDUC i'DEPTH HILTI CP 618 FIRESTOO PUTTY STICK(FLUSH VITH TOP SURFACE IF DEVICE). ■T RATING IS 3-HOUR FOR CP680-75/25'CR CP680 110/4'AND 2-PO.R FOR CP680 160/6'. • NOTE t FIR CONCRETE ROOR OVER ICTAL DECKING APPLICATIONS,A CP 6D0 METAL 1 MUTE'FIR COCRETE FLOOR OVER METAL DECKING APPLICATIORS,A CP 680 OCTAL DECK ADAPTER IS REQUIRED.METAL IECKING DEPTH IS 3',MOCK I NECK ADAPTOR IS REQUIRED.IETAI DECKING DEPTH fS 3',MAI(1MM Flpre 19 Flom 20 METAL PIPE THROUGH CONCRETE FLOOR OR CONCRETE OVER METAL DECKING METAL PIPE THROUGH CONCRETE FLOOR OR CONCRETE OVER METAL DECKING F-RATING=2-1R. F-RATING=3-OIL TOO VIEW 7-RATING=0-HR. SECTION A-A T-RATING=0-IBR. TOOTIEW 1 SECTION A-A A ....1..),n .; A 11 0 NIMINIIIII SIMIAN , fp .. i , X 4 i 1111111 L COCRETE TIER ASSEMBLY(2-IBL FIRE-RATING/I L CONCRETE RER ASSEMBLY(3-OR.FIRE-RATING) A LIMTVE1ORT LR TOOAL WEIGHT COCRETE FLOM Mk 2-1/2'THICK). A.LIGHTWEIGHT OR PI M4L W IGHT COCRETE FLED OM 4-1/2'TIOCK). I STEEL FUE R LIT/FLOOR ASSEMBLY-RCM.WEIGHT CONCRETE FLIER IL STEEL FLN37R UNIT/FLED ASSEMBLY-MRMN.VEIDIT CONCRETE FLIER 00N 2-1/2'THICIO OVER METAL DECKING (MIN 4-1/2' THICK)OVER METAL DECKING. 2 PE)ETRATII6 ITEM TO BE ME OF THE FOUNDING r 2.PENETRATDC ITEM TO BE OE OF TIE FLLLOYING' A.MAXIMUM 6'NOMINAL DIAMETER STEEL PIPE(SCHEME 40 OR HEAVIER). A.MOM 6'TO@TAL DIAMETER STEEL PIPE(SCIEDOILE 40 IR FEAVIER). IL MAXIMUM 6'NOMINAL DIAMETER CAST IRON PIPE. L MAXIM UN 6.10MINAL DIAMETER CAST IRO(PIPE. C.MAXIMUM 6'MOCK DIAMETER DIPPER PIPE. C.MA10MM 6'10014Y DIAMETER COPPER PIPE. II.MAXIMUM 6'NOMINAL DIAMETER STEEL CIRCUIT. D.MAXIMUM 6'100141E DIAMETER STEEL COOIAT. E.MAXIMUM 4'IOLINAL DIAETER ENT. E.MAXIMIM 4'IOTDLY.DIMCTER ENT. 3.NLLU CP 680 CAST-IN FTRESTEP DEVICE CAST CR DEWED INTO CONCRETE 3.MOLT{CP 680 CAST-IN FTRESTE'DEVICE CAST OR GROUTED INTO CONCRETE FLOOR(SEE TABLE MEOW). FLIER(SEE TARE IELOV). )OL PIP2'DINETER PRODUCT DESCRIPTOR MDl PIPE DIAMETER PRODUCT DESCRIPTION 2' CP680 7525' 2' CP680 75/25' 6' CP680 110/4' 3'TO 4' CP680 1110/4' 6' CP680 160/6' 4'TO 6' CP680 160/6' MITES.L FOR COCRETE FLOOR OVER OCTAL DECKING APPLICATORS,A CP 680 CAST-IN KITES 1 L FIR CONCRETE FUOR OVER METAL DECKING APPLICATIONS,A CP 610 CAST-IN FRRESTOO DEVICE METAL DECK ADAPTER 1S REQUIRED META.DECKING DEPTH FIRESTCP DEVICE FETAL LEEK ADAPTER IS REQUIRED OCTAL DECKING DEPTH 411 A 3',MAXIMM IS 3',MAXDOI Page 8 of 9 ER-5071 FID(re 21 Flpre 22 • PLASTIC PIPE TIRUJGH CONCRETE FLOOR OR CONCRETE OVER METAL DECKING PLASTIC PIPE THROUGH CONCRETE FLAIR IJR CONCRETE OVER METAL DECKING F-RATING•2-HR. F-RATIO=3-IR. TOP V1EV T-RATIO=0-OR. TOP IO (HR.VIEW T-RAT =O AND 3- ' SECT1O!A-A A.al SECTORA-A Ao—) 1 ilill Y, ` �(rVOi 12� o'y/ • i • i -11 Q . X x• Z Ao--e! A.•=0-1 L CECRETE FL�t ASSEMBLY(2-1R.FIRE-ROTUND I.CDCRETE FLOW ASSEMBLY(3-AR.FIRE-RATING). A LIGHT UGHT OR DERMAL WEIGHT CONCRETE FLC(R DIN.2-1/2'THICK). A.LIGHTWEIGHT fR KRAAL WEIGHT CONCRETE FLU(MIN.4-1/2'NICK). &STEEL FLIER LMT/FLER ASSEMBLY-KI NN.WEIGHT CDCRETE FLOUR &STEEL ROAR LADT/FL ASSEMBLY-NORMAL VEIEW CDCRETE FL®2 (NIL 2-1/2'THICK)OVER METAL DECKDNG (NRN.4-1/2'THICE)AVER METAL DECKING2.PENETRATING ITEM TO BE OE OF THE FICCXIO G(SEE TABLE BELOW). 2.PENETRATING ITEM TO BE DE TIE FLLLW'ING(SEE TABLE BELOW) A MAXIMUM 6'TO NAL DIAMETER PVC PLASTIC PPE(CELLULAR AND REID cam. I147(IMN 6'NOMINAL DIAMETER PVC PLASTIC PIPE(CELLULAR AHD SEO CORCY. S.MAXIMA 6'NOMINAL DIAMETER CPVC PLASTIC PIPE. &MAX(M1N b'NOMINAL DOAMETER CPVC PLASTIC PIPE. a 61171 CP 680 CAST-IN FIRESTEP DEVICE,CASs ER WAITED IN70 CONCRETEnm 3 HILL CP 680 CAST-IN FIRESTIP DEVICE,CAST ER GROUTED INTO CDCRETE FLIER (SEE TABLE BELW). (SEE TABLE BELOW). N PIPE DIAMETER TYPE IF PIPE PRODUCT DESCRIPTION ION PIPE DIAMETER TYPE CF PIPE `IO PRODUCT DESCRIPTION I RATING' 1-1/2'TO 2' PVC,CPVC CP680 75/25' 1-1/2•TO 2' PVC,CPVC CP680 75/25' 3 MR 3'TO 4' PVC,CPVC CP680 110/4' 3'TO 4' PVC,CPVC CP680 110/4' D RR 6' PVC,CPVC CP680 160/6' 6' PVC,CPVC CP680 160/6' 0)R NOTES I.CLOSED OR VENTED PIPING SYSTEMS(PVC= SCEDUE 40,CPVC=SIR 17X NOTES L CLOSED ER VENTED PIPING SYSTEMS(PVC=SCEDUE 40,CPVC=SIR 17). 2 TER CECRETE BOOR OVER METAL DECKING APPLICATIONS.A CP 680 METAL DECK 2.FIR CONCRETE FUER OVER MEIN.DECKING APPLICATIONS,A CP 680 METAL DECK ADAPTER IS REQUIRED.METAL DECKING DEPTH 15 3',MAXINAD( ADAPTER IS REQUIRED.METAL DECINE DEPTH E 3', MKIMLM 3 PLASTIC PIPES USED IN COLAINCTIIN WITH TOUT CP 680 110/4'MD CP 680 160/6' 3.PLASTIC PIPES USED IN COUACTIDN VITH MITI CP 680 110/4'AND CP 680 160/6' MUST BE INSTALLED FROM THE TIP SIDE IT THE ASSEMBLY. MUST SE INSTALLED MN THE TIP SIDE IF THE ASSEMBLY. • flpre 23 Flgre 24 PLASTIC PIPE THROUGH CONCRETE FLOOR OR CONCRETE OVER METAL DECKING PLASTIC PIPE THROUGH CONCRETE FLOOR OR CONCRETE OVER METAL DECKING F-RATIG=2-IR. E,VIEW F-RATING• 3-TR TIP VIEW T-RATING=0-I1R. T-RATING=0-MR. A-c0-1 SECTION A-A Acl--1 SELTIO!A-A y LP-`': • © '�' © '•� •'�� ( . �— • . � I 1.. N • 0 • 1•. t.• ,• Q , • X Z 6 A<21 A<3.—I I.CLM6RETE FLERR ASSEMBLY(2-IR FIRE-RATING). 1 CIERETE FUE R ASSEMBLY(3-TR.FIRE-RATING). A.LIGHTVEICI ER NORMAL WEIGHT CDCRETE FLmt(NIL 2-V2'THICK). A LIGHTWEIGHT ER NORMAL VCIOiIT CECRETE RmR OM 4-1/2'THICK). &STEEL FIJIR UOT/FLmt ASSEMBLY-TONAL WEIGHT CONCRETE FUUO B.STEEL FLmi UOT/FLER ASSEMBLY-TONAL WEIGHT CONCRETE FLIER UM.2-1/2'THICK)OVER METAL DECKING QOM 4-1/2'THICK)OVER METAL MODE 2 PEETRATING ITEMS TO HE OE IF THE FLU-WING. 2.PENETRATING OEM TO BE OE IF THE FTLLOWDO(SEE TABLE BELN T. A.MAi1M14 4'TONAL DIAMETER ABS PLASTIC PIPE(CELLULAR ER SELID CE D. A.MAXIMUM 4'IONINLAL DIAMETER ADS PLASTIC PIPE(CELLULAR AND SOLID CORE). &NOMINAL 6'DIAMETER TRW PLASTIC PIPE. A OCTAL 6'DIAMETER FRPP PLASTIC PIPE S.HILTI CP 680 CAST-IN MISTED'DEVICE CAST ER GRUJTED D41D CONCRETE FLIER 3 10LT1 CP 680 CAST-IN FIRESIEP DEVICE CAST ER CREWED INTO CONCRETE FLIER (SEE TABLE BaW). (SEE TABLE BEM. NO(PIPE DIAMETER TYPE ME PIPE PRODUCT DESCRIPTOR TOL PIPE DIAMETER TYPE IF PIPE PRODUCT➢CSCRIPTIER 1-1/2'TO 2' ABS CP680 75/25' 2' ABS CP680 75/25' 6' ADS CP600 110/4' 3'TO 4' ABS CP680 110/4' 6' FRPP CP600 110/6' 6' TRW CP680 160/6' NOTES.1 CLOSED ER VENTED PIPING SYSTEMS(ABS,FRPP=SCMEDU.E 40). HOLES.I.CLOSED O VENTED PIPING SYSTEMS(ABS,FRPP=SCHEDULE 40). • 2.FIR CONCRETE FLEER OVER METAL DECKING ARPLICATIOLC,A CP 680 METAL DOCK 2.TER CDCRETE FLU OVER METAL DECKING APPLICAIIEIS,A CP 680 METAL DECK ADAPTER IS REQUIRED.METAL DECKING DEPTH I5 3',MARINA ADAPTER IS REQUIRED METAL DECKING DEPTH IS 3',MAX11AAL 3,PLASTIC PIPES USED DI CINJUICTION WITH HILT!CP 680 00/4'AND CP 680 160/6' 3 PLASTIC PIPES USED IN CI)&LPCTICI WITH HETI CP 680 110/4'AND CP 680 I60/6' MIST DE INSTALLED FROM THE TIP SIDE IF THE ASSEMBLY. MIST BE INSTALLED FROM TIE TIP SIDE OF THE ASSEMBLY. Page 9 of 9 ER-5071 III Fi 25rigor*26 SINGLE CABLE OR SUNNEDTHROUGH CABLE THROUGH CONCRETE FLEBTt OR CONCRETEINSULATED METAL PIPE THROUGH CONCRETE FLDDR OR CONCRETE OVER METAL DECKING OVER METAL DECKING F-RATIM = 34R F-RATD16*t-IFt TO•VEV T-RATIM =0-I4R. VIEWT-RATDG=0-IR . ...'.-. :.,. SECTOR A-AS— Ao.l O © III r 3 ',C` . li�TrDre © I.CONCRETE FLIER ASSEMBLY 634R.FIRE-RAM.. A<31 . 2 1 A LIORVEI(MT DR NORMAL VEIG-IT CONCRETE FLOM QIINIMIM 4-1/2'THIC &STEEL FLOP UN(Tiri. ASSEMBLY-PON WL VEI(3TT CONCRETE FLIER (MINDEN 4-1/2'THICK)OVER META DECKING. 2 SDGLE CABLE 6 BUNDLED CABLE CONSISTING IF AMY 6 THE FKLEDAT . I.CONCRETE F E R ASSEMBLY(2-11.FIRE-RATDID. A IMXDOI 300 PAIR 14 24 AVG TELEPI#CABLE WITH PVC JACKET. A LIGHTWEIGHT IR KRAAL WEIGHT CONCRETE FLOUR 04N 2-Vr 1HICK) &HPXIMR 500 KCNL PURER CABLE VITH PVC JACKET. L STEEL RIIR MT/FLU ASSEMBLY-Wt9AL HEIGHT COERETE FLU C.HIXIMIT 7/C 1111 12 AVG PVVER CABLE VITH PVC JACKET. RR 2-1/r THICK)OVER METAL DECKING D.IMXDDM(24 FIBER)1/2'DIAMETER FIBER-OPTIC CABLE. 2.PENETRATING ITEM TO BE OE 6 TIE FILMING(SEE TABLE TELOV). E N&XDO1 3/C NO.12 AVG METAL-CLAD CABLE. A,MAXIMM 4'MORN&DIAMETER STEEL PIPE(SCIEDIU 40 CR IEAVIERX 1 HILTI CP 680 CAST-IN FIRESTCP DEVICE,CAST ER(ROUTED DM CONCRETE FLCDR &NAXIMM 4'IOINAL DIAMETER COPPER PIPE. (SEE TAKE BELOW. a IOQNAL 3/4'THICK AB/PVC FLEXIBLE FOAM PIPE IPSUUTIOL 4.HOIDEN I'DEPTH HILTI CP 618 FIRESTIP PUTTY STICK APPLIED AROUND SDELE 4.HILO EP 680 CAST-IN FIRESTEP DEVICE CAST ER(REUTED D(TO CONCRETE ROM CAKE OR CARE DIRGE(FLUSH VITH TIP SURFACE OF DEVICO. (SEE TABLE BEUN). INAX.BMA.6 CARL PPfDI.Ci➢ESCRPTITN NON PIPE DIAMETER AB/PVC THICKNESS PRODUCT DESCRIPTION 2' CP 680 75/25' 4' 3/4' CP680 7525' 4-1R' CP 609 Don' r 3/4' CP680 110/4' 6-1/2' CP 680 160/6' 4' 3/4' CP680 160/6' NOTE.FIR CUCRETE FLOM OVER METAL DECKING APPLICATDRS, NOTE.FIR COINER ORR OVER METAL DECKING APPLICATDRS, • A CP 680 METAL DECK ADAPTER IS REQUIRED METAL DECKING A CP 680 METAL DECK ADAPTER IS REGVIRE0.METAL DECKDG DEPTH IS 3',1W(IMM DEPTH IS 3',MODEM Flpure 27 INSULATED METAL PIPE THROUGH CONCRETE Far OR CONCRETE INSULATED METAL PIPE THROUGH CONCRETE FLOOR OR CONCRETE OVER METAL DECKING OVER METAL DECKING F-RATING=34R.. F-RATING=2-IR T-RAIDS=0-HR.AND 1-IR. 11P VIEW T-RATING=0-4R. TFP VIM pT SECTION A-A SECT A-A di 0 Jfr' • till G MOM _ `^tea y.. MilflairiliNgr tUPill o I © ' t1J ft O O A 41 XOF . .. A.o-+ Q X I.CCICIETE FUER ASSENIET(3-1R FIRE-RATING). I.CONCRETE FLOUR ASSEMBLY(2-TAL i -RATING. A LIGHTWEIGHT IR N1@ML WEIGHT CONCRETE FLIER 0411.4-1/2'HOCK). A LIGOVEDi4 IR TONAL VOW COERETE 11.WO O4N 2-1/2'THICK). I STEEL FLU OQT/F'Lmt ASSEMBLY-NRMAL WEIGHT CONCRETE PURR &STEEL FLUOR L IT/FLECR ASSEM LY-IOTMAI WEIGHT COCRETE FLOOR 00L 4-1/2'THICK)OVER METAL DECKING UQN 2-1/2'THICK)OVER METAL tECKDK 2.PENETRATING ITEM 10 BE ONE 6 TIE FIUI OVING(SEE TABLE OWN). 2 PCIETRATDIG ITEM TO BE CAE 6 THE FILMING. A IMX114M 4'MRINAL DIAMETER STEEL PIPE(SCIEDLLE 40 IR WAVIER), A W.KD0R 4'MMNAL DIAMETER STEEL PIPE(SCIEILE 4D IR HEAVIER). 3.RAXD4M 4'WOG DIAETER CIMPFR PIPE. &WAD)M 4'NOOK DIAMETER COPPER PIPE. 3.NOMINAL 3/4'THICK AB/PVC FI GGIE FOAM PIPE DISU AT@L 3.HAXDUM 2'THICK GLASS-FIBER PIPE INSILATIW(35 PCF DENSITY).JOINTS MUST 4.HILT!CP 680 CAST-IN FRESH"DEVICE CAST 6 010WTER INTO CUCKIE FLEUR BE SEALED VITO METAL FASTEMERS OR SWPLIED TAPE. (SEE TABLE BCLUV). 4.H4.T1 CP 68D CAST-IN FREST6 DEVICE CAST IR GROUTED INTO(OYRETE FLOOR GEE TAKE BELOW. KN.PIPE DIAMETER GLASS-FIBER THICKESS PRODUCT BESCROTION 1/2' 1' CP680 75/2S' M34 PIPE RANETER AD/PVC THICKNESS PRODUCT DESCRIPTION 1 RATING r I' CP68D 110/4' 3/4' CP680 D0 r/4' 1 IR 2' 2' CP680 160/6' 1111 1' 3/4' CP680 160/6' 0 W 1' I' CP680 160/6' MUTE.FIR CONCRETE FLIER OVER METAL DECKING APPULATO6, MITE.FIR COCRETE OM OVER OCTAL DECKING APPLICATORS, A CP 680 METAL DECK ADAPTER IS REQUIRED.METAL DECKING A CP 680 METAL DECK ADAPTER IS REWIRED.METAL DECKING DEPTH IS 3',MAXIMAL DEPTH IS 3',MAXIMA