Loading...
Report )-:03'3. - 0003-7 OFFICE COPY 1100 1=EE 4 /JZ 1YUb tibikHL • W .YAT T , G DIVISION . . . . . . . FIRE PROTECTION , INC. • 9095 S.W. Burnham Tigard, OR 97223 SANDBURG WAREHOUSE 7100 SW SANDBURG STREET TIGARD, OR �`c�EO PROFFS (9/" 73OP \MaX 157 E by Max E Colley: OREGON Date: '4/?cH9.9-4 Coll ey• 2022.02.24 441xco4'- ' 07:15:58 -08'00' EXPIRES:DECEMBER 31,2023 FIRE PROTECTION SEISMIC CALCULATIONS TOLBraceTM Seismic Bracing Calculations V8.8.115 Contractor: Coastal Fire Design Project Address: Sandburg warehouse Address: 3301 Parker Lane Springfield,Oregon 97477 E.T•N 7100 SW Sandburg Street Phone: 458-250-8375 Pavel*�e"e�µ`0`" 'ee Tigard OR Licence: Nicet III 4105218 Job#C22-86 Calculations based on 2016 NFPA Pamphlet#13 Brace Information TOLCOTM Brace Components Maximum Brace Length 7'o"(2.134 m) TOLCOTN Component Listed Load Adjusted Load Diameter of Brace 1" Fig. 1001 Clamp 2000 lbs(907 kg) 1414 lbs(641 kg) Fig.980-5/8"Universal Swivo 2100 lbs(953 kg) 1485 lbs(674 kg) Type of Brace Sch.40 See Fastener Information Angle of Brace 45° Min. 'Calculation Based on CONCENTRIC Loading 'Please Note:These calculations are for TOLCO TM components only.Use of any other components voids these calculations and the listing of the assembly. Least Rad.of Gyration 0.42"(11 mm) Seismic Brace Assembly Detail LIR Value 200 Max Horizontal Load 1310 lbs(594 kg) Fastener Information Orientation to Connecting Surface NFPA Type E Fastener j Type 5/8in.x 5 1/2in.Thru Bolt Diameter 5/8in. Length 5 1/2in. Maximum Load 560 lbs(254 kg) Brace Identification on Plans Brace A Prying Factor N/A Brace Type Lateral[X] Longitudinal[ ] 4-Way[ ] Sprinkler System Load Calculation (Fpw=CpWp) Cp = 0.5 Diameter Type Length Total Length Weight Per Unit Length Total Weight 6"(150 mm) Sch. 10 13 ft(4 m) 13 ft(4 m) 23.03 lb/ft(34.27 kg/m) 299 lbs(136 kg) 2.5"(65 mm) Sch. 10 50 ft(15.2 m) 50 ft(15.2 m) 5.89 lb/ft(8.77 kg/m) 294 lbs(133 kg) I Subtotal Weight 593 lbs(269 kg) Wp(incl.15%) 682 lbs(309 kg) Main Size Type/Sch. Spacing(ft) I Total(Fpw) 341 lbs(155 kg) 6" Sch.10 13 Maximum Fpw per 9.3.5.5.2(if applicable) 4039 lb(1832 kg) {TOLBraceTM Version 81 Use of TOLBraceTM is subject to terms and conditions per the end user license agreement TOLBraceTM Seismic Calculation Sandburg warehouse Job#C22-86 7100 SW Sandburg Street E_T•N Powering✓aseless Wtvlde de Brace Identification Brace A Brace Type(Per NFPA#13) NFPA Type E Braced Pipe(ft) 6"Sch.10 Steel Pipe Spacing of Brace 13'0"(3.96 m) Orientation of Brace Lateral Bracing Material 1"Sch.40 4 Maximum Brace Length 7'0"(2.13 m) Slenderness Ratio used for Load Calculation 200 True Angle of Brace for Calculation 45° Type of Fastener 5/8in.x 5 1/2in.Thru Bolt Length of Fastener 5 1/2in. Summary of Pipe within Zone of Influence 6"Sch.10 Steel Pipe(152.4 mm) 13 ft(4 m) 2.5"Sch.10 Steel Pipe(63.5 mm) 50 ft(15.2 m) Allowance for Heads and Fittings 15% • Conclusions • • Total Adjusted Load of Pipe in Zone of Influence 341 lbs(155 kg) • Material Capacity 1310 lbs(594 kg) Fastener Capacity 560 lbs(254 kg) Fig. 1001 Clamp 1414 lbs(641 kg) Fig.980-5/8"Universal Swivel 1485 lbs(674 kg) • Structural Member Structural Beam Calculations prepared by Shawn Fenneran The description of the Structural Member is for informational purposes only. TOLBrace'M software calculates the brace assembly only,not the structure it is attached to. Calculated with TOLBrace""8 Visit us at www.lolco.com TOLBraceTM Seismic Bracing Calculations V8.8.115 Contractor: Coastal Fire Design Project Address: Sandburg warehouse Address: 3301 Parker Lane Springfield,Oregon 97477 E:I•N 7100 SW Sandburg Street Pinwthv Bll.SrneaG Mrialude Phone: 458-250-8375 Tigard,OR Licence: Nicet III#105218 Job#C22-86 Calculations based on 2016 NFPA Pamphlet#13 Brace Information TOLCOTM Brace Components 1 Maximum Brace Length 7'0"(2.134 m) TOLCOTM Component Listed Load Adjusted Load Diameter of Brace 1" Fig.4L Clamp 2000 lbs(907 kg) 1414 lbs(641 kg) r Fig.980-5/8"Universal Swive 2100 lbs(953 kg) 1485 lbs(674 kg) Type of Brace Sch.40 See Fastener Information 'Calculation Based on CONCENTRIC Loading Angle of Brace 45° Min. 'Please Note:These calculations are for TOLCOTM components only.Use of any other components voids these calculations and the listing of the assembly. Least Rad.of Gyration 0.42°(11 mm) Seismic Brace Assembly Detail L/R Value 200 Max Horizontal Load 1310 lbs(594 kg) ToLro F G sao—,� a ' Fastener Information BRACE PIPE � Orientation to Connecting Surface NFPA Type E Fastener Type 5/8in.x 5 1/2in.Thru Bolt TOLCG FIG 4L Diameter 5/8in. Length 5 1/2in. 41 Maximum Load 560 lbs (254 kg) • ri Brace Identification on Plans Brace B Prying Factor N/A Brace Type Lateral[ ] Longitudinal[X] 4-Way[ ] Sprinkler System Load Calculation (Fpw=CpWp) Cp= 0.5 Diameter Type Length Total Length Weight Per Unit Length Total Weight 6"(150 mm) Sch. 10 25 ft(7.6 m) 25 ft(7.6 m) 23.03 lb/ft(34.27 kg/m) 576 lbs(261 kg) • • w_, Subtotal Weight 576 lbs(261 kg) Wp(incl. 15%) 662 lbs(300 kg) Main Size Type/Sch. Spacing(ft) L. Total(Fpw) 331 lbs(150 kg) 6" Sch.10 25 Maximum Fpw per 9.3.5.5.2(if applicable) N/A (TOLBraceTM Version 81 Use of TOLBracer.is subject to terms and conditions per the end user license agreement TOLBraceTM Seismic Calculation Sandburg warehouse Job#C22-86 7100 SW Sandburg Street Esc i eN wiviBrace Identification Brace B vrnwmg8 s,accm om Brace Type(Per NFPA#13) NFPA Type E Braced Pipe(ft) 6"Sch.10 Steel Pipe Spacing of Brace 25'0"(7.62 m) Orientation of Brace Longitudinal Bracing Material 1"Sch.40 Maximum Brace Length 7'0"(2.13 m) Slenderness Ratio used for Load Calculation 200 True Angle of Brace for Calculation 45° Type of Fastener 5/8in.x 5 1/2in.Thru Bolt Length of Fastener 5 1/2in. Summary of Pipe within Zone of Influence 6"Sch.10 Steel Pipe(152.4 mm) 125 ft(7.6 m) Allowance for Heads and Fittings 15% Conclusions Total Adjusted Load of Pipe in Zone of Influence 331 lbs(150 kg) Material Capacity 1310 lbs(594 kg) Fastener Capacity 560 lbs(254 kg) r Fig.4L Clamp 1414 lbs(641 kg) Fig.980-5/8"Universal Swivel 1485 lbs(674 kg) Structural Member Structural Beam Calculations prepared by Shawn Fenneran The description of the Structural Member is for informational purposes only. TOLBraceT""software calculates the brace assembly only,not the structure it is attached to. Calculated with TOLBrace18 8 Visit us at www.lolco.com i ./ IVE FEB r 4 202 _I 1 Y OF IIUAHL .4 4-, = ''la DING DIVISION ,.: : : *-lo s. • . . . . W YAT T FIRE PROTECTION, INC. 9095 S.W. Burnham Tigard, OR 97223 SANDBURG WAREHOUSE 7100 SW SANDBURG STREET TIGARD, OR ���EO PROFESS P\��aGi N E�� /OF M a x E Digitally signed 95730PE by Max E Colley: OREGON Date: %CI19'261N C' ' I I ey• 2022.02.24 MgkcouSk • 07:15:58 -08'00' EXPIRES:DECEMBER 31,2023 FIRE PROTECTION SEISMIC CALCULATIONS TOLBraceTM Seismic Bracing Calculations V8.8.115 Contractor: Coastal Fire Design Project Address: Sandburg warehouse Address: 3301 Parker Lane ►T`� Springfield,Oregon 97477 7100 SW Sandburg Street Phone: 458-250-8375 Pmvcn"ap BusinessNiruMwrde Tigard,OR Licence: Nicet III#105218 Job#C22-86 Calculations based on 2016 NFPA Pamphlet#13 Brace Information TOLCOTM Brace Components Maximum Brace Length 7'o"(2.134 m) TOLCOTM Component Listed Load Adjusted Load Diameter of Brace 1" Fig. 1001 Clamp 200D lbs(907 kg) 1414 lbs(641 kg) Fig.980-5/8"Universal Swive 2100 lbs(953 kg) 1485 lbs(674 kg) Type of Brace Sch.40 See Fastener Information 'Calculation Based on CONCENTRIC Loading Angle of Brace 45° Min. `Please Note.These calculations are for TOLCO'""components only.Use of any other components voids these calculations and the listing of the assembly. Least Rad.of Gyration 0.42"(11 mm) Seismic Brace Assembly Detail UR Value 200 Max Horizontal Load 1310 lbs(594 kg) Fastener Information Orientation to Connecting Surface NFPA Type E Fastener Type 5/8in.x 5 1/2in.Thru Bolt Diameter 5/8in. Length g 5 1/2in. Maximum Load 560 lbs(254 kg) _ -- Brace Identification on Plans Brace A Prying Factor N/A Brace Type Lateral[X] Longitudinal[ ) 4-Way[ ] Sprinkler System Load Calculation (Fpw=CpWp) Cp= 0.5 Diameter Type Length Total Length Weight Per Unit Length Total Weight 6"(150 mm) Sch. 10 13 ft(4 m) 13 ft(4 m) 23.03 lb/ft(34.27 kg/m) 299 lbs(136 kg) 2.5"(65 mm) Sch. 10 50 ft(15.2 m) 50 ft(15.2 m) 5.89 lb/ft(8.77 kg/m) 294 lbs(133 kg) Subtotal Weight 593 lbs(269 kg) Wp(incl. 15%) 682 lbs(309 kg) Main Size Type/Sch. Spacing(ft) I Total(Fpw) 341 lbs(155 kg) s Sch.10 13 Maximum Fpw per 9.3.5.5.2(if applicable) 4039 lb(1832 kg) (TOLBraceT"Version B) Use of TOLBrace'"is subject to terms and conditions per the end user license agreement TOLBraceTM Seismic Calculation Sandburg warehouse Job#C22-86 7100 SW Sandburg Street E_T•IV Powering 60s4nens Whdavtde Brace Identification Brace A Brace Type(Per NFPA#13) NFPA Type E Braced Pipe(ft) 6"Sch.10 Steel Pipe Spacing of Brace 13'0"(3.96 m) Orientation of Brace Lateral Bracing Material 1"Sch.40 Maximum Brace Length 7'0"(2.13 m) Slenderness Ratio used for Load Calculation 200 True Angle of Brace for Calculation 45° Type of Fastener 5/8in.x 5 1/2in.Thru Bolt Length of Fastener 5 1/2in. Summary of Pipe within Zone of Influence 6"Sch.10 Steel Pipe(152.4 mm) 13 ft(4 m) 2.5"Sch.10 Steel Pipe(63.5 mm) 50 ft(15.2 m) Allowance for Heads and Fittings 15°/0 Conclusions Total Adjusted Load of Pipe in Zone of Influence 341 lbs(155 kg) Material Capacity 1310 lbs(594 kg) Fastener Capacity 560 lbs(254 kg) Fig. 1001 Clamp 1414 lbs(641 kg) Fig.980-5/8"Universal Swivel 1485 lbs(674 kg) Structural Member Structural Beam Calculations prepared by Shawn Fenneran "The description of the Structural Member is for informational purposes only. TOLBraceTM software calculates the brace assembly only,not the structure it is attached to. Calculated with TOLBrace"'B Visit us at www.tolco.com TOLBraceTM Seismic Bracing Calculations V8.8.115 Contractor: Coastal Fire Design Project Address: Sandburg warehouse Address: 3301 Parker Lane Springfield,Oregon 97477 Ei `T •N 7100 SW Sandburg Street Phone: 458-250-8375 Frnwr+ng ats'+ress wwiihvide Tigard,OR Licence: Nicet III#105218 Job#C22-86 Calculations based on 2016 NFPA Pamphlet 813 Brace Information TOLCOTM Brace Components • Maximum Brace Length 7'i)"(2.134 m) TOLCOTM Component Listed Load Adjusted Load Diameter of Brace 1 Fig.4L Clamp 2000 lbs(907 kg) 1414 lbs(641 kg) Fig.980-5/8"Universal Swive 2100 lbs(953 kg) 1485 lbs(674 kg) Type of Brace Sch.40 See Fastener Information `Calculation Based on CONCENTRIC Loading Angle of Brace 45'Min. 'Please Note:These calculations are for TOLCO T"components only.Use of any other components voids these calculations and the listing of the assembly. Least Rad.of Gyration 0.42"(11 mm) Seismic Brace Assembly Detail LIR Value 200 lo'_co FIG 950� Max Horizontal Load 1310 lbs(594 kg) > y Fastener Information BRACE Orientation to Connecting Surface NFPA Type E Fastener Type 5/8in.x 5 1/2in.Thru Bolt FIG 4L Diameter 5/8in. Length 9 5 1/2in. � Maximum Load 560 lbs(254 kg) Brace Identification on Plans Brace B Prying Factor N/A Brace Type Lateral[ ] Longitudinal[XI 4-Way[ Sprinkler System Load Calculation (Fpw=CpWp) Cp = 0.5 Diameter Type Length Total Length Weight Per Unit Length Total Weight 6"(150 mm) Sch. 10 25 ft(7.6 m) 25 ft(7.6 m) 23.03 lb/ft(34.27 kg/m) 576 lbs(261 kg) Subtotal Weight 576 lbs(261 kg) Wp(incl. 15%) 662 lbs(300 kg) Main Size Type/Sch. Spacing(ft) I Total(Fpw) 331 lbs(150 kg) 6" Sch.10 25 Maximum Fpw per 9.3.5.5.2(if applicable) N/A {TOLBraceT"Version 8} Use of TOLBraceT"is subject to terms and conditions per the end user license agreement TOLBraceTM Seismic Calculation Sandburg warehouse Job#C22-86 7100 SW Sandburg Street 1.1•N Brace Identification Brace B N+en gees ressc , Brace Type(Per NFPA#13) NFPA Type E Braced Pipe(ft) 6"Sch.10 Steel Pipe Spacing of Brace 25'0"(7.62 m) Orientation of Brace Longitudinal Bracing Material 1"Sch.40 Maximum Brace Length 7'0"(2.13 m) Slenderness Ratio used for Load Calculation 200 True Angle of Brace for Calculation 45° Type of Fastener 5/8in.x 5 1/2in.Thru Bolt Length of Fastener 5 1/2in. Summary of Pipe within Zone of Influence 6"Sch.10 Steel Pipe(152.4 mm) 125 ft(7.6 m) Allowance for Heads and Fittings 15% Conclusions Total Adjusted Load of Pipe in Zone of Influence 331 lbs(150 kg) Material Capacity 1310 lbs(594 kg) Fastener Capacity 560 lbs(254 kg) Fig.4L Clamp 1414 lbs(641 kg) Fig.980-5/8"Universal Swivel 1485 lbs(674 kg) Structural Member Structural Beam Calculations prepared by Shawn Fenneran "The description of the Structural Member is for informational purposes only. TOLBrace""software calculates the brace assembly only,not the structure it is attached to. Calculated with TOLBrace,"6 Visit us at w ww.tolco.com OFFICE COPY �;I I Y OF TIGARD UILDING DIVISION r .% W YAT T FIRE PROTECTION , INC. 9095 S.W. Burnham Tigard, OR 97223 SANDBURG WAREHOUSE 7100 SW SANDBURG STREET TIGARD, OR ,et.0 PROFFS a�\ ��G` N ��� o' Max E Digitally signed 95730PE by Max E Colley: OREGON Date: 4'4Rcti a.2°I^ Co I I ey• 2022.02.17 Mqx ca��E ' 10:45:1 1 08'00' EXPIRES:DECEMBER 31,2023 FIRE PROTECTION HYDRAULIC CALCULATIONS < 0 W YAT T FIRE PROTECTION, INC. 9095 S.W. Burnham Tigard,OR 97223 Fire Hydrant Fire Flow PROJECT 6955 SW Sandburg St ADDRESS CROSS STREET FLOW HYDRANT 6755 SW Sandburg St. LOCATION STATIC 82 PITOT RESIDUAL 23, 4" port Hose Monster flowed. GPM 1803 GPM AT 20 PSI 3516 calculated per NFPA 291 DATED 12.10.18 8:45 AM MONITOR HYDRANT 6825 SW Sandburg St. LOCATION STATIC 78 RESIDUAL 64 DATED 12.10.18 8:45 AM WITNESS WITNESSED BY Kay Landsiedel TITLE ORGANIZATION City of Tigard Public Works SIGNATURE PERFORMED BY Jack Gardner CALCULATION SUMMARY Project Name: Sandburg Warehouse Offices Project Location: 7100 SW Sandburg Street Contract No. : C22-86 City: Tigard, OR 97223 Design Areas Design Area Calc. Mode Occupancy Area of Total Water Pressure @ Min. Min. Min. Calculated Hose Margin To Name (Model) Application Source Density Pressure Flow Heads Streams Source (ft2) (gpm) (psi) (gpm/kz) (psi) (gpm) # (gpm) (psi) 1 Demand (HW) Grp A Plastics 2000 1770.5 Required 0.6 11 55.8 22 500 2.9 61.6 2 Demand (HW) Ord Grp 11 900 378.5 Required 0.2 32.7 64 2 250 13.5 63.7 File:C:DWG\Sandburg Warehouse 7100 SW Sandburg Street Tigard OR11 CFD Drawings11 In Process Date 2/15/2022 Drawings\Sandburg Warehouse.dwg Page 1 Copyright©2002-2012 Tyco Fire Protection Products HYDRAULIC CALCULATIONS for Job Information Project Name:Sandburg Warehouse Offices Contract No.:C22-86 City: Tigard, OR 97223 Project Location: 7100 SW Sandburg Street Date:2/15/2022 Contractor Information Name of Contractor: CGH LLC Address: 2480 NE Century Blvd City: Hillsboro, OR 977214 Phone Number: E-mail: Name of Designer: S.Fenneran Authority Having Jurisdiction: City of Tigard Design Remote Area Name 1 Remote Area Location Warehouse Occupancy Classification Grp A Plastics Density(gpm/ft') 0.6 Area of Application(fr) 2000 Coverage per Sprinkler(ft2) 93 Number of Calculated Sprinklers 22 In-Rack Demand(gpm) 0 Special Heads Hose Streams(gpm) 500 Total Water Required(incl.Hose Streams)(gpm) 1770.5 Required Pressure at Source(psi) 61.6 Type of System Wet Volume-Entire System (gal) 2792.7 gal Water Supply Information Date 12/10/2018 Location 6955 SW Sandburg Street Source SRC Notes File:C:1DWG\Sandburg Warehouse 7100 SW Sandburg Street Tigard OR11 CFD Drawings11 In Process Drawings\Sandburg Warehouse.dwg Date 2/15/2022 Copyright 2002-2012 Tyco Fire Protection Products Page 2 Job Sandburg Warehouse Offices Hydraulic Analysis for : 1 Calculation Info Calculation Mode Demand Hydraulic Model Hazen-Williams Fluid Name Water @ 60F (15.6C) Fluid Weight, (Ib/k3) N/A for Hazen-Williams calculation. Fluid Dynamic Viscosity, (Ib•s/ft2) N/A for Hazen-Williams calculation. Water Supply Parameters Supply 1 : SRC Flow(gpm) Pressure(psi) 0 78 1803 64 Supply Analysis Static Pressure Residual Flow Available Total Demand Required Pressure Node at Source Pressure (gPm) Pressure(psi) (gpm) (psi) (psi) (psi) SRC 78 64 1803 64.5 1770.5 61.6 • Hoses Inside Hose Flow I Standpipe Demand(gpm) Outside Hose Flow(gpm) Additional Outside Hose Flow(gpm) 500 Other(custom defined) Hose Flow(gpm) Total Hose Flow(gpm) 500 Sprinklers Ovehead Sprinkler Flow(gpm) 1270.5 InRack Sprinkler Flow(gpm) 0 Other(custom defined)Sprinkler Flow(gpm) 0 Total Sprinkler Flow(gpm) 1270.5 Other Required Margin of Safety(psi) 0 SRC -Pressure(psi) 61.6 SRC -Flow(gpm) 1270.5 Demand w/o System Pump(s) N/A File:C:1DWG\Sandburg Warehouse 7100 SW Sandburg Street Tigard OR\1 CFO Drawings11 In Process Drawings\Sandburg Warehouse.dwg Date 2/15/2022 Copyright 5 2002-2012 Tyco Fire Protection Products Page 3 Job:Sandburg Warehouse Offices Hydraulic Analysis for : 1 •Supply*system Demand•Add.Out.Hese a AveilableAt Source 100- 90- �tl i 70- 84.505101770.5gpm r L.62. 11 60 d 3 BD a 40 VD1 20- 16- 0 0 500 600 700 800 800 1000 100 1200 1300 1400 1500 1600 1700 1800 1900 Flow,gpm File:C:\DWG\Sandburg Warehouse 7100 SW Sandburg Street Tigard OR11 CFD Drawings\1 In Process Date 2/15/2022 Drawings\Sandburg Warehouse.dwg Page 4 Copyright®2002-2012 Tyco Fire Protection Products Job:Sandburg Warehouse Offices Hydraulic Analysis for : 1 Graph Labels Label Description Values • Flow (gpm) Pressure (psi) S1 Supply point#1 -Static 0 78 52 Supply point#2-Residual 1803 64 D1 Elevation Pressure 0 22.1 D2 System Demand 1270.5 61.6 D3 System Demand+Add.Out.Hose 1770.5 61.6 Curve Intersections & Safety Margins Intersection Safety Margin Curve Name Pressure (psi) Flow (gpm) Pressure (psi) @ Flow (gpm) Supply 69.3 1398.1 2.9 1770.5 Open Heads Required Calculated Head Ref. Head Type Coverage K-Factor Density Flow Pressure Density Flow Pressure (ft9) (gpm/psis/2) (gpm/ft2) (gpm) (psi) (gpm/ft2) (gpm) (Psi) SI Overhead 93 16.8 0.6 55.8 11 0.651 60.5 13 Sprinkler S10 Overhead 93 16.8 0.6 55.8 11 0.614 57.1 11.5 Sprinkler S11 Overhead 93 16.8 0.6 55.8 11 0.604 56.2 11.2 Sprinkler S12 Overhead 93 16.8 0.6 55.8 11 0.601 55.8 11.1 Sprinkler S13 Overhead 93 16.8 0.6 55.8 11 0.601 55.9 11.1 Sprinkler S14 Overhead 93 16.8 0.6 55.8 11 0.602 56 11.1 Sprinkler S15 Overhead 93 16.8 0.6 55.8 11 0.607 56.4 11.3 Sprinkler 616 Overhead 93 16.8 0.6 55.8 11 0.618 57.5 11.7 Sprinkler S17 Overhead 93 16.8 0.6 55.8 11 0.649 60.3 12.9 Sprinkler S18 Overhead 93 16.8 0.6 55.8 11 0.642 59.7 12.6 Sprinkler S19 Overhead 93 16.8 0.6 55.8 11 0.641 59.6 12.6 Sprinkler S2 Overhead 93 16.8 0.6 55.8 11 0.613 57 11.5 Sprinkler S20 Overhead 93 16.8 0.6 55.8 11 0.642 59.7 12.6 Sprinkler File:C:\DWG1Sandburg Warehouse 7100 SW Sandburg Street Tigard OR\1 CFD Drawings\1 In Process Drawings 1Sandburg Warehouse.dwg Date 2/15/2022 Copyright©2002-2012 Tyco Fire Protection Products Page 5 S21 Overhead 93 16.8 0.6 55.8 11 0.645 59.9 12.7 Sprinkler 522 Overhead 93 16.8 0.6 55.8 11 0.653 60.7 13.1 Sprinkler S3 Overhead 93 16.8 0.6 55.8 11 0.603 56.1 11.2 Sprinkler S4 Overhead 93 16.8 0.6 55.8 11 0.6 55.8 11 Sprinkler SS Overhead 93 16.8 0.6 55.8 11 0.6 55.8 11 Sprinkler S6 Overhead 93 16.8 0.6 55.8 11 0.601 55.9 11.1 Sprinkler S7 Overhead 93 16.8 0.6 55.8 11 0.606 56.4 11.3 Sprinkler S8 Overhead 93 16.8 0.6 55.8 11 0.618 57.5 11.7 Sprinkler S9 Overhead 93 16.8 0.6 55.8 11 0.651 60.6 13 Sprinkler File:C:\DWG\Sandburg Warehouse 7100 SW Sandburg Street Tigard OR11 CFD Drawings11 In Process Drawings\Sandburg Warehouse.dwg Date 2/1512022 Copyright©2002-2012 Tyco Fire Protection Products Page 6 Job:Sandburg Warehouse Offices Hydraulic Calculations/Fluid Delivery Time Analysis Node Data Node# Type K-Fact. Discharge Coverage Tot. Pres. Req. Pres. Elev Hgroup Open/Closed Overdischarge Density Elev. Pres. Req. Discharge gpm ft2 psi psi ft gpm/Psi' gpm gpm/ft2 psi gpm S4 Overhead Sprinkler 16.8 55.8 93 11 11 21.76 HEAD Open 0 0.6 -22 55.8 S5 Overhead Sprinkler 16.8 55.8 93 11 11 21.71 HEAD Open 0 0.6 -22 55.8 S12 Overhead Sprinkler 16.8 55.8 93 11.1 11 21.75 HEAD Open 0.0 0.601 -22 55.8 S13 Overhead Sprinkler 16.8 55.9 93 11.1 11 21.71 HEAD Open 0.1 0.601 -22 55.8 S6 Overhead Sprinkler 16.8 55.9 93 11.1 11 21.67 HEAD Open 0.1 0.601 -22 55.8 S14 Overhead Sprinkler 16.8 56 93 11.1 11 21.66 HEAD Open 0.2 0.602 -22 55.8 S3 Overhead Sprinkler 16.8 56.1 93 11.2 11 21.81 HEAD Open 0.3 0.603 -22 55.8 S11 Overhead Sprinkler 16.8 56.2 93 11.2 11 21.8 HEAD Open 0.4 0.604 -22 55.8 S7 Overhead Sprinkler 16.8 56.4 93 11.3 11 21.62 HEAD Open 0.6 0.606 -21.9 55.8 S15 Overhead Sprinkler 16.8 56.4 93 11.3 11 21.61 HEAD Open 0.6 0.607 -21.9 55.8 S2 Overhead Sprinkler 16.8 57 93 11.5 11 21.85 HEAD Open 1.2 0.613 -22 55.8 S10 Overhead Sprinkler 16.8 57.1 93 11.5 11 21.85 HEAD Open 1.3 0.614 -22 55.8 S8 Overhead Sprinkler 16.8 57.5 93 11.7 11 21.57 HEAD Open 1.7 0.618 -21.9 55.8 S16 Overhead Sprinkler 16.8 57.5 93 11.7 11 21.57 HEAD Open 1.7 0.618 -21.9 55.8 S19 Overhead Sprinkler 16.8 59.6 93 12.6 11 21.71 HEAD Open 3.8 0.641 -22 55.8 S20 Overhead Sprinkler 16.8 59.7 93 12.6 11 21.66 HEAD Open 3.9 0.642 -22 55.8 S18 Overhead Sprinkler 16.8 59.7 93 12.6 11 21.75 HEAD Open 3.9 0.642 -22 55.8 521 Overhead Sprinkler 16.8 59.9 93 12.7 11 21.61 HEAD Open 4.1 0.645 -21.9 55.8 S17 Overhead Sprinkler 16.8 60.3 93 12.9 11 21.8 HEAD Open 4.5 0.649 -22 55.8 S1 Overhead Sprinkler 16.8 60.5 93 13 11 21.89 HEAD Open 4.7 0.651 -22.1 55.8 S9 Overhead Sprinkler 16.8 60.6 93 13 11 21.89 HEAD Open 4.8 0.651 -22.1 55.8 S22 Overhead Sprinkler 16.8 60.7 93 13.1 11 21.57 HEAD Open 4.9 0.653 -21.9 55.8 060 Node 13.3 21.85 NODE -22 063 Node 13.3 21.85 NODE -22 061 Node 17.4 19.44 NODE -21 File:C:1DWG1Sandburg Warehouse 7100 SW Sandburg Street Tigard OR11 CFD Drawings11 In Process Drawings\Sandburg Warehouse.dwg Date 2/15/2022 Copyright 02002-2012 Tyco Fire Protection Products Page 7 Job: Sandburg Warehouse Offices Hydraulic Calculations/Fluid Delivery Time Analysis Node Data Node# Type K-Fact. Discharge Coverage Tot. Pres. Req. Pres. Elev Hgroup Open/Closed Overdischarge Density Elev. Pres. Req. Discharge gpm/psih gpm ft2 psi psi ft gpm gpm/ft2 psi gpm 062 Node 17.4 19.44 NODE -21 004 Node 17.5 19.44 NODE -21 005 Node 17.7 19.44 NODE -21 006 Node 17.8 19.44 NODE -21 007 Node 17.9 19.44 NODE -21 008 Node 18 19.44 NODE -21 009 Node 18 19.44 NODE -21 010 Node 18 19.44 NODE -21 011 Node 18 19.44 NODE -21 047 Node 22.1 18.81 NODE -20.7 046 Node 22.1 18.81 NODE -20.7 045 Node 22.2 18.81 NODE -20.7 044 Node 22.3 18.81 NODE -20.7 043 Node 22.5 18.81 NODE -20.7 036 Node 22.9 18.81 NODE -20.7 038 Node 22.9 18.81 NODE -20.7 039 Node 22.9 18.81 NODE -20.7 040 Node 23 18.81 NODE -20.7 041 Node 23 18.81 NODE -20.7 042 Node 23.4 18.81 NODE -20.7 140-0 Node 31.6 3.88 NODE -14.2 140-I Node 32.4 3.4 NODE -14 141 Node 33.6 0.99 NODE -13 142 Node 36.8 -4 NODE -10.8 143-0 Node 38.1 -4 NODE -10.8 File:C:\DWG\Sandburg Warehouse 7100 SW Sandburg Street Tigard OR11 CFD Drawings\1 In Process Drawings\Sandburg Warehouse.dwg Date 2/15/2022 Copyright®2002-2012 Tyco Fire Protection Products Page 8 Job: Sandburg Warehouse Offices Hydraulic Calculations/Fluid Delivery Time Analysis Node Data Node# Type K-Fact. Discharge Coverage Tot. Pres. Req. Pres. Elev Hgroup Open/Closed Overdischarge Density Elev. Pres. Req. Discharge gpm/psih gpm ft2 psi psi ft gpm gpm/ft2 psi gpm 143-I Node 43.6 -4 NODE -10.8 144 Node 46.6 - -4 NODE -10.8 146 Node 59.9 -29 NODE 0 SRC Supply -1270 5 61.6 -29 SUPPLY 0 • • File:C:\DWG1Sandburg Warehouse 7100 SW Sandburg Street Tigard OR11 CFD Drawings\1 In Process Drawings Sandburg Warehouse.dwg • Date 2/15/2022 Copyright 02002-2012 Tyco Fire Protection Products Page 9 Job:Sandburg Warehouse Offices Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict(Pf) (ft) (gpm/psi') (gam) (in) (ft) (ft) (psi) (psi) Path No: 1 S4 21.76 16.8 55.8 2.5 7.42 120 11 S3 21.81 16.8 81.1 2.635 0 0.0195 0.0 7.42 0.1 S3 21.81 16.8 56.1 2.5 7.42 120 11.2 S2 21.85 16.8 137.2 2.635 0 0.0517 0.0 7.42 0.4 52 21.85 16.8 57 2.5 lx(us.Tee-Br)=16.47 1.11 120 11.5 060 21.85 194.2 2.635 16.47 0.0985 0 17.58 1.7 060 21.85 60.5 2.5 lx(us.Tee-Br)=16.47 2.42 120 13.3 061 19.44 254.7 2.635 16.47 0.1627 1 18.89 3.1 061 19.44 0 6 12.5 120 17.4 062 19.44 254.7 6.357 0 0.0022 0 12.5 0.0 062 19.44 255.1 6 12.5 120 17.4 004 19.44 509.8 6.357 0 0.0081 0 12.5 0.1 004 19.44 175.3 6 12.5 120 17.5 005 19.44 685.1 6.357 0 0.0139 0 12.5 0.2 005 19.44 -94.4 6 12.46 120 17.7 006 19.44 590.7 6.357 0 0.0106 0 12.46 0.1 006 19.44 -94.9 6 12.5 120 17.8 007 19.44 495.8 6.357 0 0.0077 0 12.5 0.1 007 19.44 -99.9 6 12.46 120 17.9 00B 19.44 395.9 6.357 0 0.0051 0 12.46 0.1 008 19.44 -98.5 6 12.5 120 18 009 19.44 297.4 6.357 0 0.003 0 12.5 0.0 009 19.44 -97.7 6 12.46 120 18 010 19.44 199.7 6.357 0 0.0014 0 12.46 0.0 010 19.44 -97.3 6 lx(us.Tee-Br)=37.72 12.5 120 18 011 19.44 102.5 6.357 37.72 0.0004 0 50.22 0.0 011 19.44 0 2.5 3x(us.Tee-Br)=49.42 103.63 120 18 036 18.81 102.5 2.635 49.42 0.0301 0.3 153.05 4.6 036 18.81 0 6 12.5 120 22.9 038 18.81 102.5 6.357 0 0.0004 0 12.5 0 038 18.81 97.3 6 12.46 120 22.9 039 18.81 199.7 6.357 0 0.0014 0 12.46 0.0 File:C:1DWG1Sandburg Warehouse 7100 SW Sandburg Street Tigard OR11 CFD Drawings11 In Process Drawings1Sandburg Warehouse.dwg Date 2/15/2022 Copyright©2002-2012 Tyco Fire Protection Products Page 10 Job:Sandburg Warehouse Offices Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict(Pf) (ft) (gpm/psPh) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 1 039 18.81 97.7 6 12.5 120 22.9 040 18.81 297.4 6.357 0 0.003 0 12.5 0.0 040 18.81 98.5 6 12.46 120 23 041 18.81 395.9 6.357 0 0.0051 0 12.46 0.1 041 18.81 99.9 6 lx(us.Tee-Br)=37.72 2.02 120 23 042 18.81 495.8 6.357 37.72 0.0077 0 39.74 0.3 042 18.81 774.7 6 lx(us.90)=17.6 24.01 120 23.4 140-0 3.88 1270.5 6.357 17.6 0.0438 6.5 41.62 1.8 140-0 3.88 0 6 0.49 31.6 BFG-300 140-1 3.4 1270.5 0 0 1.1377 0.2 *** 0.49 0.6 140-1 3.4 0 6 2.41 120 32.4 141 0.99 1270.5 6.357 0 0.0438 1 2.41 0.1 141 0.99 0 6 lx(us.90)=13.5 4.99 120 33.6 142 -4 1270.5 6.02 13.5 0.0571 2.2 18.49 1.1 142 -4 0 6 40.62 140 36.8 143-0 -4 1270.5 6.4 0 0.0318 0 40.62 1.3 143-0 -4 0 6 3.04 38.1 Deringer 30 143-I -4 1270.5 0 0 1.8054 0 *** 3.04 5.5 143-I -4 0 6 lx(us.Tee-Br)=28.93 24.31 120 43.6 144 -4 1270.5 6.02 28.93 0.0571 0 53.24 3 144 -4 0 10 lx(us.Tee-Br)=49.14 462.72 120 46.6 146 -29 1270.5 10.1 lx(us.90)=21.62 70.76 0.0046 10.8 533.48 2.4 146 -29 0 6 30 120 59.9 SRC -29 1270.5 6.02 0 0.0571 0 30 1.7 SRC 61.6 File:C:\DWG1Sandburg Warehouse 7100 SW Sandburg Street Tigard OR11 CFD Drawings\1 In Process Drawings\Sandburg Warehouse.dwg Date 2/15/2022 Copyright®2002-2012 Tyco Fire Protection Products Page 11 Job:Sandburg Warehouse Offices Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psiY) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 2 S5 21.71 16.8 55.8 2.5 7.42 120 11 S6 21.67 16.8 30.5 2.635 0 0.0032 0.0 7.42 0.0 S6 21.67 16.8 55.9 2.5 7.42 120 11.1 S7 21.62 16.8 86.5 2.635 0 0.022 0.0 7.42 0.2 S7 21.62 16.8 56.4 2.5 7.42 120 11.3 S8 21.57 16.8 142.8 2.635 0 0.0557 0.0 7.42 0.4 S8 21.57 16.8 57.5 2.5 2x(us.Tee-Br)=32.95 55.6 120 11.7 047 18.81 200.3 2.635 32.95 0.1042 1.2 88.55 9.2 047 18.81 0 6 12.5 120 22.1 046 18.81 200.3 6.357 0 0.0014 0 12.5 0.0 046 18.81 200.3 6 12.5 120 22.1 045 18.81 400.6 6.357 0 0.0052 0 12.5 0.1 045 18.81 184.7 6 12.5 120 22.2 044 18.81 585.4 6.357 0 0.0104 0 12.5 0.1 044 18.81 94.4 6 12.46 120 22.3 043 18.81 679.8 6.357 0 0.0137 0 12.46 0.2 043 18.81 94.9 6 lx(us.Tee-Br)=37.72 10.48 120 22.5 042 18.81 774.7 6.357 37.72 0.0175 0 48.2 0.8 042 23.4 Path No: 3 S5 21.71 16.8 55.8 2.5 7.42 120 11 S4 21.76 16.8 25.3 2.635 0 0.0023 0.0 7.42 0.0 S4 11 Path No: 4 S12 21.75 16.8 55.8 2.5 7.42 120 11.1 Sll 21.8 16.8 81.3 2.635 0 0.0196 0.0 7.42 0.1 S11 21.8 16.8 56.2 2.5 7.42 120 11.2 S10 21.85 16.8 137.4 2.635 0 0.0519 0.0 7.42 0.4 S10 21.85 16.8 57.1 2.5 lx(us.Tee-Br)=16.47 1.11 120 11.5 063 21.85 194.5 2.635 16.47 0.0987 0 17.58 1.7 063 21.85 60.6 2.5 lx(us.Tee-Br)=16.47 2.42 120 13.3 062 19.44 255.1 2.635 16.47 0.1631 1 18.89 3.1 062 17.4 File:C:\DWG\Sandburg Warehouse 7100 SW Sandburg Street Tigard OR\1 CFD Drawings\1 In Process Drawings\Sandburg Warehouse.dwg Date 2/15/2022 Copyright©2002-2012 Tyco Fire Protection Products Page 12 Job:Sandburg Warehouse Offices Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psis) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 5 S13 21.71 16.8 55.9 2.5 7.42 120 11.1 S14 21.66 16.8 30.4 2.635 0 0.0032 0.0 7.42 0.0 S14 21.66 16.8 56 2.5 7.42 120 11.1 S15 21.61 16.8 86.4 2.635 0 0.022 0.0 7.42 0.2 S15 21.61 16.8 56.4 2.5 7.42 120 11.3 516 21.57 16.8 142.8 2.635 0 0.0557 0.0 7.42 0.4 S16 21.57 16.8 57.5 2.5 2x(us.Tee-Br)=32.95 55.6 120 11.7 046 18.81 200.3 2.635 32.95 0.1043 1.2 88.55 9.2 046 22.1 Path No: 6 S13 21.71 16.8 55.9 2.5 7.42 120 11.1 S12 21.75 16.8 25.4 2.635 0 0.0023 0.0 7.42 0.0 S12 11.1 Path No: 7 S19 21.71 16.8 59.6 2.5 7.42 120 12.6 S18 21.75 16.8 55.2 2.635 0 0.0096 0.0 7.42 0.1 S18 21.75 16.8 59.7 2.5 7.42 120 12.6 S17 21.8 16.8 115 2.635 0 0.0373 0.0 7.42 0.3 S17 21.8 16.8 60.3 2.5 2x(us.Tee-Br)=32.95 10.94 120 12.9 004 19.44 175.3 2.635 - 32.95 0.0815 1 43.89 3.6 004 17.5 Path No: 8 S19 21.71 16.8 59.6 2.5 7.42 120 12.6 S20 21.66 16.8 4.4 2.635 0 0.0001 0.0 7.42 0 S20 21.66 16.8 59.7 2.5 7.42 120 12.6 S21 21.61 16.8 64 2.635 0 0.0126 0.0 7.42 0.1 521 21.61 16.8 59.9 2.5 7.42 120 12.7 S22 21.57 16.8 124 2.635 0 0.0429 0.0 7.42 0.3 S22 21.57 16.8 60.7 2.5 2x(us.Tee-Br)=32.95 55.6 120 13.1 045 18.81 184.7 2.635 32.95 0.0897 1.2 88.55 7.9 045 22.2 File:C:\DWG\Sandburg Warehouse 7100 SW Sandburg Street Tigard OR11 CFD Drawings\1 In Process Drawings\Sandburg Warehouse.dwg Date 2/15/2022 Copyright 0 2002-2012 Tyco Fire Protection Products Page 13 Job:Sandburg Warehouse Offices Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/Psi') (gpm) (in) (It) (ft) (Psi) (psi) Path No: 9 Si 21.89 16.8 60.5 2.5 lx(us.Tee-Br)=16.47 6.31 120 13 060 21.85 60.5 2.635 16.47 0.0114 0.0 22.78 0.3 060 13.3 Path No: 10 S9 21.89 16.8 60.6 2.5 lx(us.Tee-Br)=16.47 6.31 120 13 063 21.85 60.6 2.635 16.47 0.0114 0.0 22.78 0.3 063 13.3 Path No: 11 005 19.44 0 2.5 4x(us.Tee-Br)=65.9 103.63 120 17.7 044 18.81 94.4 2.635 65.9 0.0259 0.3 169.52 4.4 044 22.3 Path No: 12 006 19.44 0 2.5 4x(us.Tee-Br)=65.9 103.63 120 17.8 043 18.81 94.9 2.635 65.9 0.0261 0.3 169.52 4.4 043 22.5 Path No: 13 007 19.44 0 2.5 4x(us.Tee-Br)=65.9 103.63 120 17.9 041 18.81 99.9 2.635 65.9 0.0287 0.3 169.52 4.9 041 23 Path No: 14 008 19.44 0 2.5 4x(us.Tee-Br)=65.9 103.63 120 18 040 18.81 98.5 2.635 65.9 0.028 0.3 169.52 4.7 040 23 Path No: 15 009 19.44 0 2.5 4x(us.Tee-Br)=65.9 103.63 120 18 039 18.81 97.7 2.635 65.9 0.0276 0.3 169.52 4.7 039 22.9 Path No: 16 010 19.44 0 2.5 4x(us.Tee-Br)=65.9 103.63 120 18 038 18.81 97.3 2.635 65.9 0.0274 0.3 169.52 4.6 038 22.9 File:C:1DWG\Sandburg Warehouse 7100 SW Sandburg Street Tigard OR11 CFD Drawings\1 In Process Drawings\Sandburg Warehouse.dwg Date 2/15/2022 Copyright®2002-2012 Tyco Fire Protection Products Page 14 Job:Sandburg Warehouse Offices Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict(Pf) (ft) (gpm/psi'h) (gpm) (in) (ft) (ft) (psi) (psi) * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 15.01 ft/s occurs in the following pipe(s): (062-063) • *** Device pressure loss (gain in the case of pumps) is calculated from the device's curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. • • • • File:C:\DWG\Sandburg Warehouse 7100 SW Sandburg Street Tigard OR\1 CFD Drawings\1 In Process Drawngs\Sandburg Warehouse.dwg Date 2/15/2022 Copyright®2002-2012 Tyco Fire Protection Products Page 15 Job:SandburgWarehouse Offices Device Graphs P Pressure vs. Flow Function Design Area: 1; Supply Ref.: SRC; Supply Name:SRC 85 _.... . ... . LIT 0 0 0o Flow,gpm Pressure Loss Function Design Area: 1; BFP Ref.: 329 (Deringer 30, Size = 6); Inlet Node: 143-I; Outlet Node: 143-0 7.8 6.8-1 5.5 psi @1270.5 gpm + 5.8-. . , • 4.8- 7 7 N N ;8- n. 2 8_ 1.8- 0.8- e o o a 0 = o o = Flow,gpm File:C:\DWG1Sandburg Warehouse 7100 SW Sandburg Street Tigard OR\1 CFD Drawings\1 In Process Drawings\Sandburg Warehouse.dwg Date 2/15/2022 Copyright®2002-2012 Tyco Fire Protection Products Page 16 Job:Sandburg Warehouse Offices Device Graphs Pressure Loss Function Design Area: 1; Valve Ref.: 328 (BFG-300, Size = 6); Inlet Node: 140-I; Outlet Node: 140-0 0.736 0636_.._...... .. 0.6psi@1270.5gpm 0 536- Pr a. d 0436- 3 N tl 0336- 0.236- .. 0.136-. _.. 0036-.. 0 0 0 0 0 0 0 0 0 0 n y 0 0 Flow,gpm File:C:\DWG\Sandburg Warehouse 7100 SW Sandburg Street Tigard OR\1 CFD Drawings\1 In Process Drawings\Sandburg Warehouse.dwg Date 2/15/2022 Copyright 0 2002-2012 Tyco Fire Protection Products Page 17 HYDRAULIC CALCULATIONS for Job Information Project Name:Sandburg Warehouse Offices Contract No.:C22-86 City: Tigard, OR 97223 Project Location: 7100 SW Sandburg Street Date:2/15/2022 Contractor Information Name of Contractor: CGH LLC Address: 2480 NE Century Blvd City: Hillsboro, OR 977214 Phone Number: E-mail: Name of Designer: S. Fenneran Authority Having Jurisdiction: City of Tigard Design Remote Area Name 2 Remote Area Location Wood Shop Occupancy Classification Ord Grp II Density(gpm/ft') 0.2 Area of Application(ft') 900 Coverage per Sprinkler(fe) 320 Number of Calculated Sprinklers 2 In-Rack Demand(gpm) 0 Special Heads Hose Streams(gpm) 250 Total Water Required(incl.Hose Streams)(gpm) 378.5 Required Pressure at Source(psi) 63.7 Type of System Wet Volume-Entire System (gal) 2792.2 gal Water Supply Information Date 12/10/2018 Location 6955 SW Sandburg Street Source SRC Notes File:C:1DWG\Sandburg Warehouse 7100 SW Sandburg Street Tigard ORl1 CFD Drawings11 In Process Drawings\Sandburg Warehouse.dwg Date 2/15/2022 Copyright®2002-2012 Tyco Fire Protection Products Page 18 Job:Sandburg Warehouse Offices Hydraulic Analysis for : 2 Calculation Info Calculation Mode Demand Hydraulic Model Hazen-Williams Fluid Name Water @ 60F (15.6C) Fluid Weight, (lb/ft3) N/A for Hazen-Williams calculation. Fluid Dynamic Viscosity, (Ib•s/ft2) N/A for Hazen-Williams calculation. Water Supply Parameters Supply 1 : SRC Flow(gpm) Pressure(psi) 0 78 1803 64 Supply Analysis Residual Available Static Pressure Flow Total Demand Required Pressure Node at Source (psi) Pressure (9Pm) Pressure (gpm) (psi) (psi) (psi) SRC 78 64 1803 77.2 378.5 63.7 Hoses Inside Hose Flow/Standpipe Demand(gpm) Outside Hose Flow(gpm) Additional Outside Hose Flow(gpm) 250 Other(custom defined) Hose Flow(gpm) Total Hose Flow(gpm) 250 Sprinklers Ovehead Sprinkler Flow(gpm) 128.5 InRack Sprinkler Flow(gpm) 0 Other(custom defined)Sprinkler Flow(gpm) 0 Total Sprinkler Flow(gpm) 128.5 Other Required Margin of Safety(psi) 0 SRC -Pressure(psi) 63.7 SRC -Flow(gpm) 128.5 Demand w/o System Pump(s) N/A File:C:1DWG\Sandburg Warehouse 7100 SW Sandburg Street Tigard OR11 CFD Drawings11 In Process Drawings Sandburg Warehouse.dwg Date 2/15/2022 Copyright®2002-2012 Tyco Fire Protection Products Page 19 Job:Sandburg Warehouse Offices Hydraulic Calculations/Fluid Delivery Time Analysis Node Data Node# Type K-Fact. Discharge Coverage Tot. Pres. Req. Pres. Elev Hgroup Open/Closed Overdischarge Density Elev. Pres. Req. Discharge gpm/psi h gpm ft2 psi psi ft gpm gpm/ft2 psi gpm 004 Node 40 19.44 NODE -21 005 Node 40 19.44 NODE -21 006 Node 40 19.44 NODE -21 007 Node 40 19.44 NODE -21 008 Node 40 19.44 NODE -21 009 Node 40 19.44 NODE -21 010 Node 40 19.44 NODE -21 011 Node 40 19.44 NODE -21 036 Node 40.3 18.81 NODE -20.7 038 Node 40.3 18.81 NODE -20.7 039 Node 40.3 18.81 NODE -20.7 040 Node 40.3 18.81 NODE -20.7 041 Node 40.3 18.81 NODE -20.7 042 Node 40.3 18.81 NODE -20.7 043 Node 40.3 18.81 NODE -20.7 044 Node 40.3 18.81 NODE -20.7 045 Node 40.2 18.81 NODE -20.7 046 Node 40.2 18.81 NODE -20.7 047 Node 40.2 18.81 NODE -20.7 061 Node 40 19.44 NODE -21 062 Node 40 19.44 NODE -21 070 Node 38.6 21.27 NODE -21.8 072 Node 38.7 21.23 NODE -21.8 073 Node 38.5 21.22 NODE -21.8 077 Node 36 7.5 NODE -15.8 File:C:1DWG\Sandburg Warehouse 7100 SW Sandburg Street Tigard OR11 CFD Drawings11 In Process Drawings\Sandburg Warehouse.dwg Date 2/15/2022 Copyright®2002-2012 Tyco Fire Protection Products Page 20 Job:Sandburg Warehouse Offices Hydraulic Calculations/Fluid Delivery Time Analysis Node Data Node# Type K-Fact. Discharge Coverage Tot. Pres. Req. Pres. Elev Hgroup Open/Closed Overdischarge Density Elev. Pres. Req. Discharge gpm/psis gpm ft2 psi psi ft gpm gpm/ft2 psi gpm 080 Node 36.4 7.5 NODE -15.8 140-I Node 47 3.4 NODE -14 140-0 Node 46.8 3.88 NODE -14.2 141 Node 48 0.99 NODE -13 142 Node 50.2 I -4 NODE -10.8 143-I Node 52.8 -4 NODE -10.8 143-0 Node 50.2 -4 NODE -10.8 144 Node 52.8 -4 NODE -10.8 146 Node 63.7 -29 NODE 0 S30 Overhead Sprinkler 11.2 64.4 320 33.1 32.7 7.5 HEAD Open 0.4 0.201 -15.8 64 S31 Overhead Sprinkler 11.2 64 320 32.7 32.7 7.5 HEAD Open 0.0 0.2 -15.8 64 SRC Supply -128 5 63.7 -29 SUPPLY 0 File:C:\DWG1Sandburg Warehouse 7100 SW Sandburg Street Tigard OR11 CFD Drawings11 In Process Drawings\Sandburg Warehouse.dwg Date 2/15/2022 Copyright®2002-2012 Tyco Fire Protection Products Page 21 Job:Sandburg Warehouse Offices Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psiVs) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 1 S31 7.5 11.2 64 1 lx(us.90)=2 0.92 120 32.7 077 7.5 64 1.049 2 1.1193 0 2.92 3.3 077 7.5 0 1.25 1x(us.Tee-Br)=6 16.78 120 36 073 21.22 64 1.38 2x(us.90)=6 12 0.2944 -5.9 28.78 8.5 073 21.22 0 2.5 lx(us.Tee-Br)=16.47 1.98 120 38.5 072 21.23 64 2.635 16.47 0.0126 0 18.46 0.2 072 21.23 28.9 2.5 lx(us.Tee-Br)=16.47 2.42 120 38.7 046 18.81 93 2.635 16.47 0.0252 1 18.89 0.5 046 18.81 -1.3 6 12.5 120 40.2 045 18.81 91.6 6.357 0 0.0003 0 12.5 0 045 18.81 1.5 6 12.5 120 40.2 044 18.81 93.1 6.357 0 0.0003 0 12.5 0 044 18.81 2.6 6 12.46 120 40.3 043 18.81 95.6 6.357 0 0.0004 0 12.46 0 043 18.81 3.4 6 lx(us.Tee-Br)=37.72 10.48 120 40.3 042 18.81 99.1 6.357 37.72 0.0004 0 48.2 0.0 042 18.81 29.4 6 lx(us.90)=17.6 24.01 120 40.3 140-0 3.88 128.5 6.357 17.6 0.0006 6.5 41.62 0.0 140-0 3.88 0 6 0.49 46.8 BFG-300 140-I 3.4 128.5 0 0 0.0281 0.2 *** 0.49 0.0 140-I 3.4 0 6 2.41 120 47 141 0.99 128.5 6.357 0 0.0006 1 2.41 0 141 0.99 0 6 lx(us.90)=13.5 4.99 120 48 142 -4 128.5 6.02 13.5 0.0008 2.2 18.49 0.0 142 -4 0 6 40.62 140 50.2 143-0 -4 128.5 6.4 0 0.0005 0 40.62 0.0 143-0 -4 0 6 3.04 50.2 Deringer 30 143-I -4 128.5 0 0 0.8384 0 *** 3.04 2.6 143-I -4 0 6 lx(us.Tee-Br)=28.93 24.31 120 52.8 144 -4 128.5 6.02 28.93 0.0008 0 53.24 0.0 144 -4 0 10 lx(us.Tee-Br)=49.14 462.72 120 52.8 146 -29 128.5 10.1 lx(us.90)=21.62 70.76 0.0001 10.8 533.48 0.0 File:C:\DWGlSandburg Warehouse 7100 SW Sandburg Street Tigard ORl1 CFD Drawings11 In Process DrawingslSandburg Warehouse.dwg Date 2/15/2022 Copyright©2002-2012 Tyco Fire Protection Products Page 22 Job:Sandburg Warehouse Offices Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psiY) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 1 146 -29 0 6 30 120 63.7 SRC -29 128.5 6.02 0 0.0008 0 30 0.0 SRC 63.7 File:C:1DWG1Sandburg Warehouse 7100 SW Sandburg Street Tigard OR11 CFD Drawings11 In Process Drawings\Sandburg Warehouse.dwg Date 2/15/2022 Copyright®2002-2012 Tyco Fire Protection Products - Page 23 Job:Sandburg Warehouse Offices Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict(Pf) (ft) (gpm/psit/) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 2 S30 7.5 11.2 64.4 1 1x(us.90)=2 0.92 120 33.1 080 7.5 64.4 1.049 2 1.1312 0 2.92 3.3 080 7.5 0 1.25 lx(us.Tee-Br)=6 15.66 120 36.4 070 21.27 64.4 1.38 2x(us.90)=6 12 0.2975 -6 27.66 8.2 070 21.27 -28.9 2.5 2x(us.Tee-8r)=32.95 95.19 120 38.6 062 19.44 35.5 2.635 32.95 0.0042 0.8 128.14 0.5 062 19.44 1.3 6 12.5 120 40 004 19.44 36.8 6.357 0 0.0001 0 12.5 0 004 19.44 -1.5 6 12.5 120 40 005 19.44 35.4 6.357 0 0.0001 0 12.5 0 005 19.44 -2.6 6 12.46 120 40 006 19.44 32.8 6.357 0 0.0001 0 12.46 0 006 19.44 -3.4 6 12.5 120 40 007 19.44 29.4 6.357 0 0.0000 0 12.5 0 007 19.44 -5.9 6 12.46 120 40 008 19.44 23.5 6.357 0 0.0000 0 12.46 0 008 19.44 -5.8 6 12.5 120 40 009 19.44 17.6 6.357 0 0.0000 0 12.5 0 009 19.44 -5.8 6 12.46 120 40 010 19.44 11.8 6.357 0 0 0 12.46 0 010 19.44 -5.8 6 lx(us.Tee-Br)=37.72 12.5 120 40 011 19.44 6.1 6.357 37.72 0 0 50.22 0 011 19.44 0 2.5 3x(us.Tee-Br)=49.42 103.63 120 40 036 18.81 6.1 2.635 49.42 0.0002 0.3 153.05 0.0 036 18.81 0 6 12.5 120 40.3 038 18.81 6.1 6.357 0 0 0 12.5 0 038 18.81 5.8 6 12.46 120 40.3 039 18.81 11.8 6.357 0 0 0 12.46 0 039 18.81 5.8 6 12.5 120 40.3 040 18.81 17.6 6.357 0 0.0000 0 12.5 0 040 18.81 5.8 6 12.46 120 40.3 041 18.81 23.5 6.357 0 0.0000 0 12.46 0 File:C:1DWG1Sandburg Warehouse 7100 SW Sandburg Street Tigard OR11 CFD Drawings11 In Process Drawings\Sandburg Warehouse.dwg Date 2/15/2022 Copyright©2002-2012 Tyco Fire Protection Products Page 24 Job:Sandburg Warehouse Offices Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict(Pf) (ft) (gpm/psi'/z) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 2 041 18.81 5.9 6 lx(us.Tee-Br)=37.72 2.02 120 40.3 042 18.81 29.4 6.357 37.72 0.0000 0 39.74 0 042 40.3 Path No: 3 046 18.81 0 6 lx(us.Tee-Br)=37.72 12.5 120 40.2 047 18.81 1.3 6.357 37.72 0 0 50.22 0 047 18.81 0 2.5 3x(us.Tee-Br)=49.42 103.63 120 40.2 061 19.44 1.3 2.635 49.42 0 -0.3 153.05 0 061 19.44 0 6 12.5 120 40 062 19.44 1.3 6.357 0 0 0 12.5 0 062 40 Path No: 4 070 21.27 0 2.5 1x(us.Tee-Br)=16.47 6.02 120 38.6 072 21.23 28.9 2.635 16.47 0.0029 0.0 22.49 0.1 072 38.7 Path No: 5 004 19.44 0 2.5 4x(us.Tee-Br)=65.9 103.63 120 40 045 18.81 1.5 2.635 65.9 0.0000 0.3 169.52 0 045 40.2 Path No: 6 005 19.44 0 2.5 4x(us.Tee-Br)=65.9 103.63 120 40 044 18.81 2.6 2.635 65.9 0.0000 0.3 169.52 0 044 40.3 Path No: 7 006 19.44 0 2.5 4x(us.Tee-Br)=65.9 103.63 120 40 043 18.81 3.4 2.635 65.9 0.0001 0.3 169.52 0 043 40.3 Path No: 8 007 19.44 0 2.5 4x(us.Tee-Br)=65.9 103.63 120 40 041 18.81 5.9 2.635 65.9 0.0002 0.3 169.52 0.0 041 40.3 File:C:\DWG\Sandburg Warehouse 7100 SW Sandburg Street Tigard OR\1 CFD Drawings\1 In Process Drawings\Sandburg Warehouse.dwg Date 2/15/2022 Copyright®2002-2012 Tyco Fire Protection Products Page 25 Job:Sandburg Warehouse Offices Hydraulic Calculations PIPE INFORMATION Node 1 I Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psnA) (gpm) (in) (ft) (It) (psi) (psi) Path No: 9 008 19.44 0 2.5 4x(us.Tee-Br)=65.9 103.63 120 40 040 18.81 5.8 2.635 65.9 0.0001 0.3 169.52 0.0 040 40.3 Path No: 10 009 19.44 0 2.5 4x(us.Tee-Br)=65.9 103.63 120 40 039 18.81 5.8 2.635 65.9 0.0001 0.3 169.52 0.0 039 40.3 Path No: 11 010 19.44 0 2.5 4x(us.Tee-Br)=65.9 103.63 120 40 038 18.81 5.8 2.635 65.9 0.0001 0.3 169.52 0.0 038 40.3 * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 23.91 ft/s occurs in the following pipe(s): (080-S30) *** Device pressure loss (gain in the case of pumps) is calculated from the device's curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. File:C:\DWG\Sandburg Warehouse 7100 SW Sandburg Street Tigard 01211 CFD Drawings\1 In Process Drawings\Sandburg Warehouse.dwg Date 2/15/2022 Copyright®2002-2012 Tyco Fire Protection Products Page 26 Job :SandburgWarehouse Offices Device Graphs P Pressure vs. Flow Function Design Area: 2; Supply Ref.: SRC; Supply Name:SRC 85- xa III 7s_ 70- a5= 60- ca 35- a 50- 7 45. 40- 35: 30 25 20- 1i3 10.1 5- • . 0 0 0 0 0 0 0 0 0 0 w 0 c o Flow,gpm Pressure Loss Function Design Area: 2; BFP Ref.: 329 (Deringer 30, Size = 6); Inlet Node: 143-I; Outlet Node: 143-0 7.5 6.8- 5.8In 12. ai 4.s- N N v 38- a 2.6 psi @128.5 gpm ' 2ft_ Y 18 08- Flow,gpm File: C:\DWG\Sandburg Warehouse 7100 SW Sandburg Street Tigard OR11 CFD Drawings\1 In Process Drawings\Sandburg Warehouse.dwg Date 2/15/2022 Copyright m 2002-2012 Tyco Fire Protection Products Page 27 Job: Sandburg Warehouse Offices Device Graphs Pressure Loss Function Design Area: 2; Valve Ref.: 328 (BFG-300, Size = 6); Inlet Node: 140-I; Outlet Node: 140-0 0,736- 0.636- 0 536- N Q d 0.436- YI N Q. 0 336- 0.236- 0.136- 0.036- v Flow,gpm File:C:1DWG\Sandburg Warehouse 7100 SW Sandburg Street Tigard OR11 CFD Drawings11 In Process Drawings Sandburg Warehouse.dwg Date 2/15/2022 Copyright®2002-2012 Tyco Fire Protection Products Page 28 OFFICE COPY s . . W YAT DIV1S1Qnr FIRE PROTECTION , INC. 9095 S.W. Burnham Tigard, OR 97223 SA NDBURG WAREHOUSE 7100 SW SANDBURG STREET TIGARD OR PROFFS c..9�yGIN Es% Digitally signed a 95730PE r Max E by Max E Colley: OREGON �L Date: i'CH9, Colley• . 2022.02.17 MAX cott-Ey 10:46:44 -08'00' EXPIRES:DECEMBER 31,2023 FIRE PROTECTION EQUIPMENT SUBMITTAL .tr ' SCHEDULE 10 & 40 14\ , 414" 1\.„114:4,Nif 46 44( . • ' 11 f .4. ' . sh - t1$ Always ready to protect your most valuable assets. As the leading supplier of steel sprinkler pipe,we understand that there are no second chances in fire suppression.You need products of enduring quality and exceptional strength—plus reliable service.You need Bull Moose. Bull Moose Fire Sprinkler Pipe Produc Information Nominal Pipe Size(Inches) 1" 1.1/4" 111/2" 2" 2.1/2" 3" 4" 6" 8" NPS(In.) 1" 11/4" 1-1/2" 2" 2-1/2" 3" 4" o.a(In) 1.315 1.660 1.900 2.375 2.875 3.500 4.500 6.625 8.625 1.315 1.660 1.900 2.375 2.815 3.500 4.500 0 l.a(in) 1.097 1.442 1.682 2.157 2.635 3.260 4.260 5.357 8.249 O 1.049 1.380 1.610 2.067 2.459 3.068 4.025 W Empty Weight(Ib/ft) 1.410 1.m0 2.090 2.640 3.530 4340 5.620 9.290 15.940 W 1.680 2.270 2.720 3.660 5.800 7.580 10.800 Water Filled Weight(Ib/ft) 1.820 2.518 3.053 4.223 5.893 7.957 11.796 23.038 40.006 -I 2.055 2.918 3.602 5.114 7.875 10.783 16316 0 C R R. 15.27 9.91 7.76 6.27 4.92 3.54 2.50 1.158 1.805 0 1.00 1.00 1.00 1.00 1.00 1.00 1.00 W Pieces per Lift 91 61 61 37 30 19 19 10 7 W 70 51 44 30 30 19 19 Lift Weight(Ibs)21'lengths 2,695 2,319 2,677 2,051 2,224 1,732 2,242 1,951 2,490 Lj 2,470 2,431 2,513 2,306 3,654 3,024 4,309 D1 Lift Weight(Ibs124'lengths 3,079 2,650 3,060 2,344 2,542 1,979 2,563 2,230 2,848 VI 2,822 2,778 2,872 2,635 4176 3,456 4,925 Lift Weight(11E125'lengths 3,208 2,160 3,187 2,442 2,648 2,062 2,670 2,940 2,894 2,992 2,745 4,350 3,601 5,130 1. , 7 `w`,', a 40 A AN° : OTHER BENEFITS/SERVICES: • UL listed(US&Canada)and FM approved • We have the most stocking locations in the industry, • ASTM A135 and A795 Type E, Grade A Certified for best delivery and availability • • Complies with NFPA-13,13R and 14 Plain end or roll groove • Eddy Guard IIM bacterial-resistant internal coating • Industry-leading hydraulic characteristics • Custom length options • CRR of 1.0 and greater • Hot dipped galvanization • All pipe NDT weld tested • Reddi-Pipe®red or black pipe eliminates field painting • Compatible for use in wet,dry, preaction and deluge sprinkler systems Exclusive maker of Reddi-Pipe° RED OR BLACK PAINTED PIPE. • The only maker with EPDs(to help earn LEED points). CERTIFIED °�c Us LISTED AD' t 04 APPROVEDNFPA' - "�•�•"`�""�" tom.• 800.325.4467 "' sales®BullMo! eindus ie co,m ` BULL Iy[�OSE" :'ullMooseTube.Com �`' TUBE ill Pipe Hangers Fig. 200- "Trimline" Adjustable Band Hanger (13-Line Fig.B317ONF) ®TOLCO Fig. 200F- "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig.B317ONFF) C pt us Fig. 200C- "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig.B317ONFC) LISTED Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm)thru 8" (200mm)pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled --- swivel nut design permits hanger adjustment after installation. y Features: • (1/2" 115mm)thru 2" (60mm)) Flared edges ease installation for all pipe 41�,,� \ types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily o B ' installed around pipe. \ ' For hanger with non captured nut order Fig. 200S. '; A • (21/2" (65mm)thru 8" (200mm)) Spring tension on nut holds it securely in '� hanger before installation.Adjusting nut is easily removed. '' Approvals: Underwriters Laboratories listed (1/2" (15mm)thru 8" (200mm)) -= Fig.200-1/2.200-3/n in the USA(UL)and Canada(cUL)for steel and CPVC plastic pipe and Fig.200-1 to 200-2 Fig.200-21/2 to 200-8 Factory Mutual Engineering Approved(FM) (3/4" (20mm)thru 8" (200mm)1. Conforms to Federal Specifications WW-H-171 E &A-A-1192A,Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, Type 10. Maximum Temperature: 650°F(343°C) Finish: Pre-Galvanized. Stainless Steel low3" " materials will be supplied with (2) hex nuts in place of a knurl nut. , ., '-\ Order By: Figure number and pipe size ) Designed to meet or exceed requirements of FM DS 2-0. 1 Fig.200 Fig.200C Fig.200F Pipe Size Rod Size A B Approx.Wt./100 Part No. in. (min) in. Imm) in. (mml lbs. (kg) �"1r-42ile' 200-1/2 1/2" (151 3/8'-16 31/8" 179.4) 25/8" (66.7) 11 (5.0) 200-3/4 3/4" (201 3/e-16 31/8" 179.4) 21/2" (63.5) 11 (5.0) 200-1 1" (251 3/8"-16 33/8" (85.7) 25/8" (66.7) 12 (5.5) 200-11/4 11/4' (32) 3/8"-16 33/4" (94.0) 27/8" 173.01 13 (5.9) 200-11/2 11/2" (40) 3/8"•16 37/e" (98.41 27/a' (73.01 14 (6.4) 200-2 2" 150) 3/t'-16 41/2" (114.3) 3" (76.3) 15 (6.9) 44 200-21/2 21/2" (65) 3/8"-16 55/e" (142.9) 41/8" (104.7) 27 112.3) 'iAt 200-3 3" (751 3/8"-16 57/8" (149.1) 4" (101.6) 29 113.3) Fig.200S 200-31/2 31/2" (90) 3/8'-16 73/8" (187.3) 51/4" 1133.31 34 (15.6) 200-4 4" (100) 3/8"-16 73/3" 1137.3) 5" (127.01 35 (16.0) 200-5 5" 1125) 1/2'-13 91/8" 1231.81 61/4' (156.71 66 (30.2) 200-6 6" 1150) 1/2"-13 101/8" (257.2) 63/4" (171.4) 73 (33.41 200-8 8" 1200) 1/2"-13 131/8" (333.4) 83/4" (222.21 136 (62.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. pp-Line Fire Protection Solutions 13 -Line by Ei'•IY VERTICAL MOUNT SAMMYS® ''' SAMMYS° for Wood Not less Than Wood Flooring 2"nominal width Product Features t-v2) �( ► •No pre-chilling required. • Not less than •Quick to install using the Sammy � R a°nominal Nut Dr ver with an 18V cordless thickness(2-1121 (depth or side Wood Joist drill/driver. of vertical member)T' } -. �" •Saves time from traditional DoableC dingShe do methods. For vertical use- Ceiling motel]in canter of lower loco. •Reduces installation cost. •Made in the U.S.A. *rum7 embedment into base materiallor NFPA 13 compliance. Composite!Truss Consult truss manufacturer for recommended installation point. 4 : 'Pre-tinting maybe required for GST 25a80.idol available on page 10 4 Rod Part Screw Ultimate UL Test FM Test Box Case Approvals Size Number Model Descriptions Pullout(Ibs) Load(lbs) Load(Ibs) Qty City 1/4" 8002957 GST 100 1/4x1° 210(7116'OSB) 25 125 670(3/4°Ply) 1/4" 8003957 GST 200 1M x 2" 1760 (Fir) 25 125 1/4' 8004957 GST 300 1/4 x 3" 2060(Fir) 25 125 ;398/9S.; 3/8' 8006957 GST 75 114 x 3/4" 564 (3/4"Ply) 25 125 G. 3/8" 8007957 GST 10 1/4 x 1" 210(7/16'OSB) 300 25 125 nti .;�, 670(3/4"Pry) _ li 4 �.�`-� 3/8" 8008957 GST20 1/4x 2" 1760 (Fir) 850 1475 25 125 `"� Q- 3/8• 8068925 GST 20-S6 101 x 7 1760(Fir) 850 25 125 3/8' 8009925 GST 25-380 3/8 x 2-1/2" 2113(Fir) 1500 25 125 .E• 3/8' 8010957 GST 30 1/4 x 3" 2060(Fir) 1500 1475 25 125 #14 Black Nut Driver 3/8" 8069925 GST 30-SS 1/4 x 3" 2060 (Fir) 25 125 Part#8113910 (=?-,•l;= 318' 8011925 GST40 1Mx4" 2180(Fir) 25 125 3/8' 8012925 GST 60 1l4 x 6" 2230 (Fir) 25 125 _ ;k,�:—.. 1/2• 8013925 GST2 1/4x7 1760(Fir) 25 125 1/2" 8014925 GST 2.5-380 3/8 x 2-112" 2113 (Fir) 25 125 1/2' 8015925 GST 3 114 x 3' 2275(Fir) 25 125 — 1/2" 8016925 GST4 114 x4" 2180(Fir) 25 125 1/2' 8017925 GST 6 1/4 x 6' 2230(Fir) 25 125 #14 SW Red _ Nut Driver Part#8114910 SAMMY Swivel Head° for Wood Product Features •Eliminates distortion of threaded rod. •Saves time from traditional methods. •Accommodates up to 3'V"x 12 pitch roof. •Reduces installation cost. •Mows 17°deflection from vertical. •Made in the U.S.A. I Rod Part Screw Ultimate UL Test FM Test Min Box Case Approvals Model Size Number Descriptions Pullout(Ibs) Load(Ibs) Load(Ibs) Thickness Qty Qty © 3M" 8139957 SH-GST20 1/4x7 1257(Fr) 1050 1475 25 125 125 ® 318" 8141957 SH-GST 30 1/4 x 3" 1720(Fir) 1500 1475 25 125 #14 Black Nut Driver SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installaton each time.When the face of grafter comes into pan#8113910 contact with the material you are installing into continue drilling until nut driver spins free,Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. For the most up to date information,visit wwwsammysuperscrew.com 4 V ` ,% 1+� 7 V Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig.103) B3205L -Threaded Rod (right& left hand threads) TL l*� Size Range: 3/a"-16 thru 3"-4 rod specify length il\ �1��11� Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. �111 Rod is threaded on both ends with right hand threads of the length available with left and right hand threads-specify shown. Fig. B3205L when ordering. t�1\\\�l�y�ll A Thread Size Maximum Temperature: 750°F(399°C) Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Part number, rod size, length and finish Standard Design Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) B3205-3/a x'L' 3/8"-16 21/2" (63.5) 730 (3.25) 572 (2.54) B3205-1/2 x'L' 1/2"-13 21/2" (63.5) 1350 (6.00) 1057 (4.70) B3205-5/8 x'L' 5/e"-11 21/2" (63.5) 2160 (9.61) 1692 (7.52) B3205-3/4 x'L' 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) B3205-7/8 x'L' 7/8"-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) I B3205-1 x'1' 1"-8 4" (101.6) 5900 (26.24) 4620 (20.55) B3205-11/a x'L' 11/8"-7 41/2" (114.3) 7450 (33.14) 5830 (25.93) B3205-11/4 x'L' 11/4"-7 5" (127.0) 9500 (42.25) 7440 (33.09) B3205-11/2 x'L' 11/2"-6 6" (152.4) 13800 (61.38) 10807 (48.07) B3205-13/4 x'L' 13/4"-5 7" (177.8) 18600 (82.73) 14566 (64.79) B3205-2 x'L' 2"-41/2 8" (203.2) 24600 (109.42) 19625 (87.29) 83205-21/4 x'L' 21/4"-41/2 9" (228.6) 32300 (143.67) 25295 (112.51) B3205-21/2 x11.' 21/2%4 10" (254.0) 39800 (177.03) 31169 (138.64) B3205-23/4 x'1' 23/4"-4 11" (279.4) 49400 (219.73) 38687 (172.08) B3205-3 x'L' 3"-4 12" (304.8) 60100 (267.32) 47066 (209.35) ATR - All Threaded Rod 120" (3.05m) Lengths (TOLCO Fig. 100) Fig. 99 - All Threaded Rod Cut To Length ,s�. Size Range: 3/8"-16 thru 11/2"-6 rod in 120"(3.05m)lengths or cut to length 110 Material: Steel °° _ b ,: d,111 Maximum Temperature: 750°F(399°C) .' a o Finish: Plain.Contact B-Line for alternative finishes and materials. °t,` _ o Order By: Part number, rod diameter and finish ..-'` ►-a Part No.-Size x Length Threads Recommended Load Approx.Wt./100 Ft. ATR Fig.99 Per Inch Lbs. (kN) Lbs. (kg) AIR 1/4"x 120 99-1/4"x length 20 240 (1.07) 12 (5.44) ATR 3/a"x 120 99-3/a"x length 16 730 (3.24) 29 (13.15) ATR 1/2"x 120 99-1/2"x length 13 1350 (6.00) 53 (24.04) ATR 5/8"x 120 99-5/8"x length 11 2160 (9.60) 89 (40.37) ATR 3/4"x 120 99.3/4"x length 10 3230 (14.37) 123 (55.79) AIR 7/8"x 120 99a/8"x length 9 4480 (19.93) 170 (77.11) ATR 1"x 120 99-1"x length 8 5900 (26.24) 225 (102.06) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B Pipe Hangers&Supports 236 Revised4/28/2014 y b Line by Line ticti Worldwide 1 W w tyco-fire.com Contacts Model BFV-300/BFV-300C Butterfly Valve Grooved End General Technical Description Data I. The TYCO Models BFV-300 and BFV- Approvals `i 300C Grooved End Butterfly Valves UL and ULC Listed are indicating type valves designed for FM Approved use in fire protection systems where CE Certified a visual indication of open or closed VdS Approved valve condition is required. They are Russian Fire Certificate used, for example, as system, sec- CNPP R1 Listed-APSAD tional and pump water control valves. Listed by California State Fire Marshall r They have grooved inlet and outlet con- For specific information about approvals, nections that are suitable for use with see Tables A,B,and C. grooved end pipe couplings listed or Note:All laboratory listings and approvals approved for fire protection systems. are for indoor and outdoor use. For applications requiring supervi- Sizes MODEL BFV-300 sion of the open or closed state of the 2 in.to 12 in.(DN50 to DN300) OPEN SUPERVISORY SWITCHES valve,the Gear Operators for the Model UL/ULC/FM Maximum Working BFV-300/BFV-300C Butterfly Valves feature two sets of factory installed Pressure y internal switches each having SPDT 2 in.-8 in.(DN50-DN200) 300 psi(20,7 bar) contacts,see Figure 3.The supervisory 10 in.-12 in.(DN250-DN300)..175 psi(12,1 bar) switches transfer their electrical con- VdS Maximum Working Pressure tacts when there is movement from the 2 in.-8 in.(DN50-DN200) 300 psi(20,7 bar) open or closed disc position during the 10 in.(DN250) 232 psi(16,0 bar) first two revolutions of the handwheel. 12 in.(DN300) 175 psi(12,1 bar) Note:If the butterfly valve is required in a Maximum Working Temperature foam system,verify the valve is compatible 212°F(100°C)in accordance with UL 1091 by referring to the foam concentrate manu- facturer technical literature for information about foam compatibility, and acceptable Body Ductile Iron system equipment materials of construction. Body Coating RILSAN PA11 Black Disc Ductile Iron NOTICE Disc Seal EPDM Encapsulated Upper&Lower Stem Stainless Steel The Model BFV-300/BFV-300C Handwheel Ductile Iron Grooved End Butterfly Valves (BFV-300 red painted;BFV-300C black painted) MODEL BFV-300C described herein must be installed Actuator,2 in.-6 in.(DN50-DN150): CLOSED SUPERVISORY SWITCHES and maintained in compliance with • IP65, bronze traveling nut gearbox, ductile this document, as well as with theiron housing Actuator,8 in.-12 in.(DN200-DN300): applicable standards of the NATIONAL • IP65, brass segmented gearbox, ductile iron ® 7 5T 17c FIRE PROTECTION ASSOCIATION, in housing addition to the standards of any other ,,„ authorities having jurisdiction. Failure Silicone Free Model Availability (:� � , Silicone free models are available.Contact J to do so may impair the performance TYCO sales for information. CE E A [ ��=RV of these devices. Tapping Bosses The owner is responsible for main- , ithi taining their fire protection system Two factory-plugged NPT threaded tapping bosses in the valve body are located on the and devices in proper operating con- VdS CP dition. Contact the installing contrac- up- and downstream sides of the disc for connection to valve trim. Tapping boss APPROVED tor or product manufacturer with any sizes: questions. 2 in.-3 in.(DN50-DN80) 3/8 NPT 4 in.-12 in.(DN100-DN300) 1/2 NPT Control Valve Seat Leakage IMPORTANT Class IEC 60534-4 Refer to Technical Data Sheet CLASS VI(Type C)Control Valve Seat TFP2300 for warnings pertaining to Leakage according to ANSI/FCI regulatory and health information. 70-2-2006(ASME B16.104) Page 1 of 8 JANUARY 2021 TFP1511 TFP1511 Page 2 of 8 Nominal Pipe Nominal Dimensions Valve Size OD Inches Weight Inches Inches (mm) Lb (DN) (mm) A BC D E F G H J (kg) 2 2.37 3.8 10.63 2.85 4.90 4.92 4.28 1.99 10.8 (DN50) (60,3) (96,4) (270) (72,5) (124,5) (125) (108,6) (50,5) 0 0 (4,9) 2-1/2 2.88 3.8 11.72 3.35 5.5 4.92 4.28 1.99 13.0 (DN65) (73,0) (96,4) (297,8) (85) (139,8) (125) (108,6) (50,5) 0 0 (9,9) 3 3.8 11.72 3.35 5.5 4.92 4.28 1.99 0 0 13.0 (DN6-5) 76,1 (96,4) (297,8) (85) (139,8) (125) (108,6 (50,5) (5,9) 3 3.5 3.8 12.22 3.58 5.76 4.92 4.28 1.99 0 0 13.9 (DN80) (88,9) (96,4) (310,3) (91) (146,3) (125) (108,6) (50,5) (6,3) 4 4.5 4.54 13.92 4.29 6.75 4.92 4.28 1.99 0 0 17.64 (DN100) (114,3) (115,4) (353,5) (109) (171,5) (125) (108,6) (50,5) (8,0) 5.5 5.83 16 5.16 7.93 5.91 5.79 2.32 0 0 26.4 (DN1-25) (139,7) (148) (406,6) (131) (201,5) (150) (147) (58,9) (11,9) 5 5.56 5.83 16 5.16 7.93 5.91 5.79 2.32 26.4 (DN125) (141,3) (148) (406,6) (131) (201,5) (150) (147) (58,9) 0 0 (11,9) 6.5 5.83 17.07 5.71 8.44 5.91 5.79 2.32 30,42 DN1-50 165,1 (148) (433,6) (145) (214,5) (150) (147) (58,9) 0 0 (13,8) 6 6.63 5.83 17.07 5.71 8.44 5.91 5.79 2.32 0 0 30,42 (DN150) (168,3) (148) (433,6) (145) (214,5) (150) , (147) (58,9) (13,8) 8 8.63 5.24 19.67 6.69 9.29 8.86 8.19 2.76 5.66 1.24 47.18 (DN200) (219,1) (133) (499,5) (170) (236) (225) (208) (70) (143,7) (31,4) (21,4) 10 10.75 6.26 22.46 7.68 11.1 11.14 8.19 2.91 7.21 1.65 73.41 (DN250) (273) (159) (570,5) (195) (282) (283) (208) (74) (183,1) (41,8) (33,3) 12 12.75 6.5 25.39 9.5 12.2 11.14 8.19 2.91 9.96 2.7 89.29 (DN300) (323,9) (165) (645) (241,5) (310) (283) (208) (74) (252,9) (68,5) (40,5) SEGMENTED HANDWHEEL GEAR OPERATOR 8 TO 12 INCH -E INDICATOR FLAG I (DN200 TO DN300) —C D VALVE SIZES VALVECLOSED) L. , I'�o o� F- �C 1.-:_: •I o O€ -iI ., BOSSES / G i�i_�i } B HANDWHEEL 1 INDICATOR HANDWHEEL BODY FLAG t I-4 ::: :■ TAPPINGA -- —IF l 1 , BOSSES I, (' �, I i �° � I. . 1 BOSSES :_: \ s,MI f DISC 41 MI J H COONNECTORR TRAVELLING NUT TRAVELLING NUT ELECTRICALI GEAR OPERATOR GEAR OPERATOR 2 TO 4 INCH 5 TO 6 INCH (DN50 TO DN100) (DN125 TO DN150) VALVE SIZES VALVE SIZES FIGURE 1 MODEL BFV-300/BFV-300C GROOVED END BUTTERFLY VALVE NOMINAL DIMENSIONS TFP1511 Page 3 of 8 No. Part Material Qty. No. Part Material Qty. No. Part Material Qty. 01 Body ASTM 1 15 Spring Pin ASTM 1 30 Bolt(Round) ASTM 3 A-536 A-228 A-167 02 Upper Stem AISI 410 1 16 Indicator AS619 1 31 Plate Washer AS 6 4 03 Lower Stem AISI 410 1 17 0-Ring NBR 1 32 Switch Assembly - 1 04 Disc EPDM 1 18 Cover Gasket Paper 1 33 T/R Bolt ASTM 2 A-307 05 0-Ring(P12) EPDM 4 19 Spring Pin ASTM 1 34 Tapping Screw S10C 1 05x1Tx25 A-228 ST3.5x7.5 06 Oiless B/R - 4 20 0-Ring(P10) EPDM 1 35 Tooth Washer 4# S10C 1 (MB1410) 07 2.1/2 4 Inch EPDM 1 21 Worm Shaft AISI 410 1 36 Lever ASTM 1 08 Gear Box ASTM 1 22 Bushing(1) FD-0205-45 1 37 Connector - 1 A-536 - Traveling Nut Bronze 1 23 Collar FD-0205-45 1 38 Sticker - 1 09 2-6 Inch Segment Gear C3604BD 1 24 Spring Washer ASTM 4 39 Sticker - 1 8-12 Inch A-167 10 Bushing(2) FD-0205-45 1 25 Hex Bolt ASTM 2 40 Spring Pin ASTM 1 M8 x 20L A-167 03x0.6Tx25 A-228 11 Cover ASTM 1 26 Hex Bolt ASTM 2 Headless Plu g • A-619 M8 x 25L A-167 3/8 NPT 12 Bushing Fe 1 27 Gasket Paper 1 41 2-3 Inch ASTM 2 13 Headless Wrench ASTM 1 28 Spring Pin ASTM 1 Headless Plu A-307 g Bolt M5 x 7L A-307 04x0.8tx35 A-228 1/2 NPT 14 Stem Housing Fe 1 29 Handwheel ASTM A-53fi 1 4-12 Inch 35 34 37 33 30 37 33 35 36 �V palms �30 32 mei / 34 `'L�=mac. ''1i— ' vai )* J-,,,,,r � 32 L ��� 36 �mh1E�ri11, 38,39 PMlililu(Amu, 38,39 28 � 28 31 31 0 30 30 19, 19, 29 20 40 17 14 12 18 29 20 40 17 14 12 18 i / / 16 —__ A \ \ / 16 V \ III / 11 ' 11MI 15 - *ling' LJ U 15 :J 21 -- 10 Al � 21 —�-- 10 =� -0- itlh� 13 " i; miy. a 13 v� i� — 09 22 111 —09 =1 +_ 27 \,_, 27 \�+ 23 / �r 08 I 23 :,I -08 i I 25 25 :L. 24� ��i 05 24 ill 05 � 25 �\02 II 25 /`(1 ' 0201 — I1E- 4101 — ♦ 1 IIC - 41`� ' H 04 ' i 0304' `Ia� - 03 • 06 u-1C 07 If Zr 06 _ 0. _ 07 ir- BFV-300 Normally Open Valve BFV-300C Normally Closed Valve Supervisory Switch Arrangement Supervisory Switch Arrangement FIGURE 2 MODEL BFV-300/BFV-300C GROOVED END BUTTERFLY VALVE ASSEMBLY TFP1511 Page 4 of 8 FLOW RATE IN LITERS PER MINUTE(LPM) (1 GPM=3,785 LPM) 200 400 600 1000 2000 4000 6000 10000 20000 9.01J ILII I111111II I11I111J 11 ) 11 I J I_ L I 1 II JIJ11IIIIL HIM 11 I 1 1 � 0,60 8.0 ' _ 7.0 /- 0,50 6.0 / - ' _ 0,40 5.0 - cgs' / I. 4.0 ' . M.. o===M I nuMM. u �N== , oM wI ==oo - 0,30 c Q / /� / cc a U2i 43 0 U 3.0 ti j Q2� 0,20 zZ / III ii a a Z o ?V/ e J/ 9 / o m D < 2.0 F/ J v� W7 / w� / Z- w am wco h $ �. / ti o aw y "�i C12 2w/ �`` 0,10 ai � EL f-2 / , I / f _ 0,09z p2 - 0,08 as 10 „_ ,Z /7/ ^ 0,07Z0.8 / _ 006 0.7 / // cs' - 0,05 Z 0.6 / r _ �� r 0,04 0.5 / / e2 0,03 / � / /0.4 / 0.3 ! / / ryII , 50 60 80 100 200 400 600 800 1000 2000 4000 6000 FLOW RATE IN GALLONS PER MINUTE(GPM) GRAPH A MODEL BFV-300/BFV-300C GROOVED END BUTTERFLY VALVE NOMINAL PRESSURE DROP VERSUS FLOW YELLOW L-----_1 YELLOW i I IS-1 " FIRE ALARM COMMON HIT COMMON(WHITE) END OF LINE fa II CONTROL PANEL RESISTOR SUPERVISORY RED I RED OR CIRCUIT NEXT DEVICE MODEL BFV-300/BFV-300C I 0 I GREEN GEAR OPERATOR �y 1 OPERATOR CASE CONTACT RATINGS: 1 I - GROUND 16A 125V/250 VAC BLUE 5A 24VDC I SWITCH S-1,2 LEADS PER CONTACT p SWITCH S-2, 1 LEAD PER CONTACT S-2 / COMMON(BLACK) I C�/ T I ORANGE VOLTAGE L_____J AUX.DEVICE SOURCE . _ (BELL OR HORN) FIGURE 3 MODEL BFV-300 BUTTERFLY VALVE OPEN POSITION-SUPERVISORY SWITCH OPEN POSITION MODEL BFV-300C BUTTERFLY VALVE CLOSED POSITION-SUPERVISORY SWITCH CLOSED POSITION INTERNAL SWITCH WIRING DIAGRAM TFP1511 Page 5 of 8 Nominal Pipe Part Number Agency Listing/Approval Valve Size O.D. Max.PSI BFV-300 BFV-300C CA Fire Russian Inche ncNes Inches (bar) Supv. SwENitch S CLv.OSED Switch CE UL ULC FM VdS Marshall CNPP PAVUS Fire O Cert. (D 2 (60,3) (202.38 00,7 59300G020W5 59300G020WSC ✓ ✓ ,/ ,/ ✓ ,/ 2-1/2 2.88 300 59300G025WS 59300G025WSC ✓ I I ✓ ✓ ✓ ✓ ✓ (DN65) (73,0) (20,7) 3 300 59300G026WS 59300G026WSC I I I I ✓ ✓ ✓ DN6-5 76,1 (20,7) 3 3,5 300 59300G030WS 59300G030WSC ✓ I / ✓ ✓ ✓ ✓ ✓ (DN80) (88,9) (20,7) 4 4.5 300 59300G040WS 59300G040WSC / I / I ✓ I ✓ ✓ (DN100) (114,3) (20,7) - DN125 (15.5 (200,7 59300G056WS 59300G056WSC / ✓ / ,/ ,/ ✓ ./ 5 5.56 300 59300G050WS 59300G050WSC ✓ J ✓ ✓ / ✓ ✓ ✓ (DN125) (141,3) (20,7) 6.5 300 59300G066WS 59300G066WSC I ✓ ✓ ✓ ✓ ✓ ✓ DN1-50 (165,1) (20,7) 6 6.63 300 59300G060WS 593000060WSC I I I J ✓ 1 ✓ ✓ (DN150) (168,3) (20,7) 8 8.63 300 59300G0BOWS 59300G080WSC I ✓ I ✓ ✓ ✓ ✓ J (DN200) (219,1) (20,7) 10 10.75 175 59300G100WS 59300G100WSC ✓ / I / ✓ ✓ 1 ✓ (DN250) (273) (12,1) 12 12.75 175 59300G120WS 59300G120WSC / J ✓ ✓ 1 ✓ (DN300) 323,9 (12,1) TABLE A MODEL BFV-300/BFV-300C GROOVED END BUTTERFLY VALVE WITH INTERNAL SUPERVISORY SWITCHES PART NUMBER SELECTION AND AGENCY LISTINGS/APPROVALS Nominal Pip Part Number Agency_Listinp/Approval Valve Size O.D. PSI' BFV-300 BFV-300C Inches Inches Supv.Switch Supv.Switch CE VdS CNPP DN (mm) (bar) p p OPEN CLOSED 2 2.38 300 59300G020AWS 59300G020AWSC / ✓ 7 (DN50) (60,3) (20,7) 2-1/2 2.88 300 59300G025AWS 59300G025AWSC ✓ / 7 (DN65) (73,0) (20,7) 3 300 59300G026AWS 59300G026AWSC ✓ ✓ 1 DN6-5 76,1 (20,7) 3 3,5 300 59300G030AWS 59300G030AWSC ✓ 1 1 (DN80) (88,9) (20,7) 4 (DN100) (14.5 (20,07) 59300G040AWS 59300G040AWSC ✓ J I 5.5 300 59300G056AWS 59300G056AWSC ✓ ✓ 7 DN125 (139,7) (20,7) 5 5.56 300 59300G050AWS 59300G050AWSC 7 / ✓ (DN125) (141,3) (20,7) 6.5 300 59300G066AWS 59300G066AWSC ✓ / J DN1-50 (165,1) (20,7) 6 6.63 300 59300G060AWS 59300G060AWSC 1 / J (DN150) (168,3) (20,7) 8 8.63 300 59300G080AWS 59300G080AWSC ✓ ✓ J (DN200) (219,1) (20,7) 10 10.75 175 59300G100AWS 59300G100AWSC ✓ ✓ ✓ (DN250) (273) (12,1) 12 12.75 175 59300G120AWS 59300G120AWSC ✓ 7 1 (DN300) 323,9 (12,1) TABLE B MODEL BFV-300/BFV-300C GROOVED END BUTTERFLY VALVE WITH CNPP-APSAD LARGE 100 X 100 MM FLAG AND INTERNAL SUPERVISORY SWITCHES PART NUMBER SELECTION AND AGENCY LISTINGS/APPROVALS TFP1511 Page 6 of 8 Nominal Pipe Max Agency Listing/Approval Valve Size O.D. Part Russian PSI CA Fire Inches Inches (bar) Number CE UL ULC FM VdS Marshall CNPP PAVUS Fire (DN) (mm) Cert. 2 2.38 300 59300G020NS ✓ ✓ ✓ ✓ ✓ ✓ (DN50) (60,3) (20,7) 2-1/2 2.88 300 59300G025NS ✓ ✓ ✓ ✓ ✓ ✓ I ✓ (DN65) (73,0) (20,7) 3 300 59300G026NS ✓ ✓ ✓ ✓ ✓ ✓ ✓ DN6-5 76,1 (20,7) 3 3,5 (DN80) (88,9) (200) 59300G030NS ✓ ✓ ✓ ✓ / ,/ ✓ ✓ 4 4.5 300 59300G040NS ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ (DN100) (114,3) (20,7) 5.5 300 59300G056NS ✓ ✓ / ✓ ✓ ✓ ✓ DN125 (139,7) (20,7) 5 5.56 300 59300G050NS ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ (ON125) (141,3) (20,7) 6.5 300 59300G066NS ✓ 1 ✓ ✓ ✓ ✓ ✓ DN1-50 (165,1) (20,7) 6 6.63 300 59300G060NS I I ✓ ✓ ✓ ✓ I ✓ (DN150) (168,3) (20,7) 8 8.63 300 593000080NS ✓ ✓ ✓ ✓ ✓ / ✓ / (DN200) (219,1) (20,7) 10 10.75 175 59300G100NS ✓ ✓ ✓ ✓ I ✓ I I (DN250) (273) (12,1) 12 12.75 175 59300G120NS ✓ I I ✓ I ✓ (DN300) 323,9 (12,1) TABLE C MODEL BFV-300 GROOVED END BUTTERFLY VALVE WITHOUT INTERNAL SUPERVISORY SWITCHES PART NUMBER SELECTION AND AGENCY LISTINGS/APPROVALS Part Number Nominal Gear Bernstein Bernstein Valve Size Mounting Bernstein GC-SU1Z Operator i88-IP65 Inches Type Bracket with 188-IP65 LED Switch Ex IP-66/67 ATEX (DN) Mounting Bolts Regular Switch 24V (Ex II2G Ex dlIC T6 Gb) Switch 2-4 59300SPBRACKET10 (DN50-DN100) Travelling 5-6 Nut 59300SPBRACKET20 (DN125-DN200) • 59300SPSW 59300SPSWLED 59300SPSWATEX 8 59300SPBRACKET25 (DN200) Segmented 10-12 Gear 59300SPBRACKET30 (DN250-DN300) Notes: 1. Install a single switch in either bracket mounting position to monitor Open or Closed valve condition 1 I I ° I i¢ I o o 40 49) Bernstein Switch Wiring Diagram TABLE D MODEL BFV-300 GROOVED END BUTTERFLY VALVE WITHOUT INTERNAL SUPERVISORY SWITCHES ACCESSORY EXTERNAL SUPERVISORY SWITCHES AND MOUNTING BRACKETS PART NUMBER SELECTION TFP1511 Page 7 of 8 Installation Nominal Valve Size Part Number Inches The Model BFV-300/BFV-300C (DN) BFV-300,Red Painted BFV-300C,Black Painted Grooved End Butterfly Valves may be 2-4 59300SPHWHEEL10 59300SPHWHEEL10B installed with flow in either direction (DN50-DN100) and can be positioned either horizon- 5-6(DN125-DN150) 59300SPHWHEEL20 59300SPHWHEEL20B tally or vertically. 8 59300SPHWHEEL30 59300SPHWHEEL30B The grooved end pipe couplings (DN200) used with the Model BFV-300/BFV- 10-12 59300SPHWHEEL40 59300SPHWHEEL40B 300C must be listed or approved for (DN250-DN300) fire protection service and installed in TABLE E accordance with the manufacturers BFV-300/BFV-300C GROOVED END BUTTERFLY VALVE instructions. REPLACEMENT HANDWHEEL The Model BFV-300/BFV-300C But- PART NUMBER SELECTION terfly Valve may be installed with any schedule of pressure class of pipe or tubing that is listed or approved for fire Nominal Valve Size Inches Part Number protection. (DN) Conduit and electrical connections 2-4 59300SPFLAG10 are to be made in accordance with (DN50-DN100) the authority having jurisdiction and/ 5-6(DN125-DN150) 59300SPFLAG20 or the National Electrical Code. With 8-12 reference to Figure 3, the supervisory (DN200-DN300) 59300SPFLAG30 switch is intended for connection to the supervisory circuit of a fire alarm TABLE F control panel in accordance with NFPA BFV-300 WAFER STYLE BUTTERFLY VALVE 72.The auxiliary switch is intended for INDICATOR FLAG the unsupervised connection to aux- PART NUMBER SELECTION iliary equipment in accordance with NFPA 70, National Electric Code. Care and Limited Note:Foroutdoorapplications with internal supervisory switches,it is recommended Maintenance Warranty that wiring connections be made at a temperature above 15°F(-9°C), in order Before closing a fire protection system For warranty terms and conditions,visit v lv f r maintenance or www.tyco-fire.com. 1 to insure sufficient flexibility of the wire controlvalve o co-y lead insulation. inspection work on either the valve or fire protection system which it con- trols, permission to shut down the affected fire protection systems must be obtained from the proper authorities and all personnel who may be affected by this decision must be notified. The owner is responsible for the inspection,testing,and maintenance of their fire protection system and devices in accordance with the applicable stan- dards of the NATIONAL FIRE PRO- TECTION ASSOCIATION,for example, NFPA 25, in addition to the standards of any authority having jurisdiction. Contact the installing contractor or product manufacturer with any ques- tions. Any impairment must be imme- diately corrected. It is recommended that automatic sprinkler systems be inspected,tested, and maintained by a qualified inspec- tion service. TFP1511 Page 8 of 8 Ordering Replacement Parts Procedure Note:Only items described in this section are offered as replacement parts. Contact your local distributor for avail- Handwheel ability.When placing an order,indicate Replacement handwheel includes pin. the full product name and Part Number See Table E for part numbers. (P/N). Model BFV-300, Red Painted Butterfly Valves Specify: Handwheel, (specify size) Model BFV-300 Grooved End Butter- Model BFV-300 with Internal fly Valve, P/N(specify) Open Supervisory Switches Model BFV-300C,Black Painted Specify: (specify size)Model BFV-300 Specify: Handwheel, (specify size) Grooved End Butterfly Valve, Inter- Model BFV-300C Grooved End But- nal Open Supervisory Switches, terfly Valve, P/N(specify) P/N(specify per Table A) Model BFV-300C with Internal Indicator Flag Closed Supervisory Switches Specify: Indicator P/N, (specify spe) Specify: (specify size) Model BFV- Model BFV-300, P/FlaN (specify per Table F) 300C Grooved End Butterfly Valve, Internal Closed Supervisory Switches, P/N(specify per Table A) Model BFV-300 with Internal Open Supervisory Switches, APSAD Approved Specify: (specify size)Model BFV-300 Grooved End Butterfly Valve, Internal Open Supervisory Switches, APSAD Approved, P/N(specify per Table B) Model BFV-300C with Internal Closed Supervisory Switches, APSAD Approved Specify: (specify size) Model BFV-300C Grooved End Butter- fly Valve, Internal Closed Supervi- sory Switches, APSAD Approved, P/N(specify per Table B) Model BFV-300 without Internal Supervisory Switches Specify: (specify size)Model BFV-300 Grooved End Butterfly Valve, P/N (specify per Table C) Accessories External Supervisory Switch and Mounting Bracket Note: Accessory external supervisory switches and mounting brackets are applicable only to valves without factory- installed internal supervisory switches. See Table D for switch models and part numbers. Specify: (specify size) Model BFV-300 Grooved End Butterfly Valve Exter- nal Switch Mounting Bracket, P/N (specify), with (specify quantity)Bern- stein External Switch (specify model), P/N(specify) 1400 Pennbrook Parkway,Lansdale,PA 194461 Telephone+1-215-362-0700 /'1 ' 02021 Johnson Controls.All rights 00000 .All specifications and other Information shown were current an al document revision date and are subject to change without notice. Johnson �JO%) NAO0NA1 FINF PumFcvon Assocunory and NFPA are registered trademarks of Netional Fare v,m.ceon Aasoc anm: Controls rEFLON la a naeomark of Tne Cnamourt Company IC.LLG Controls D CO® Worldwide wwwtyco-fire.com Contacts Model RM-1 Riser Manifold Commercial and Residential General Optional Pressure Relief Kits feature a 175 psi pressure relief valve and trim Description components for convenient integration into commercial and residential riser The TYCO commercial and residential manifold assemblies. = Model RM-1 Riser Manifold provide The pressure relief valve, installed in the necessary waterflow alarm, pres- manifold assemblies above the nor- sure gauge, alarm test orifice, drain, mally closed test and drain or drain and sight glass equipment in a single valve, automatically bleeds system assembly for use in NFPA 13 corn- pressure exceeding 175 psi through a mercial sprinkler systems and in NFPA flexible hose connected to the mani- 13D/13R residential sprinkler systems fold drain outlet(Ref. Figure 5),reduc- as follows: ing system pressure to 175 psi. ,1164 NFPA 13* • 1-1/2 in.(DN40) NOTICE • Male Thread x Female Thread The Model RM-1 Riser Manifolds • 2 in.-6 in.(DN50-DN150) described herein must be installed Groove x Groove and maintained in compliance with this document,as well as with the applica- NFPA 13D ble standards of the NATIONAL FIRE • 1 in.(DN25) PROTECTION ASSOCIATION(NFPA), Female Thread x Female Thread in addition to the standards of any other NFPA 13R authorities having jurisdiction. Failure to do so may impair the performance ' : • 1-1/2 in.(DN40) Male Thread x Female Thread of these devices. • 2 in. (DN50) The owner is responsible for main- taining their fire protection system and devices in proper operating con- rayy Although the Riser Manifold described in this techni- dition. Contact the installing contrac- •t cal data sheet is intended for NFPA 13 sprinkler sys- tems,it may be used for NFPA 13D or 13R residential productany sprinkler systems,where a test orifice of 2.8K or 4.2K questions. is acceptable. 5.i'a'.., The variety of sizes and grooved end Technical connections allow cost effective and easy transition to check valves,control Data valves, and system piping.The Model RM-1 Riser Manifolds may be installed Approvals either horizontally(flow switch on top) UL and ULC Listed or vertically(flow going up)orientation, FM Approved for both single sprinkler rises and floor Listed by California State Fire Marshall control in high-rises. Maximum Working Pressure 300 psi(20,7 bar) Friction Loss See Table A Test Orifice 1 in.-3 in.(DN25-DNBO)Manifolds:2.8K 4in.-6 in.(DN100-DN150)Manifolds:4.2K Finish Red Painted IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Page 1 of 8 AUGUST 2021 TFP963 TFP963 Page 2 of 8 Nominal NO DESCRIPTION P/N Nominal End Nominal Dimensions Drain 1 300 psi/2000 kPa Riser Connections Inches Size Water Pressure Gauge..90050001 Size (mm) Inches 2 Test and Drain Valve, Inches (DN) Model TD-1: (DN) 1-1/23 Inch Inlet Outlet A B C D E F G H (0N4-ON40-DN8N60) Sizolds, 1-1/2 Thread Thread 10 15-1/2 2-1/4 5-5/8 8-3/8 15 4-3/8 1-1/4 1-1/4",/ 2.8KOr (40) MNPT FNPT (254) (394) (57) (143) (213) (381) (111) (32) 46I 2.BKOif Orifice A61 G0420 4-6 Inch 2 Groove Groove 13 18 2-1/16 5-5/8 8-3/8 15-1/4 4-3/8 1-1/4 (DN100-DN150) (50) (330) (457) (53) (143) (213) (388) (111) (32) Size Manifolds, 2",4.2K Orifice A61 G0601 2-1/2 Groove Groove 13 18-1/16 2-1/16 5-5/8 8-3/8 15-1/4 4-3/8 1-1/4 3 Flow Switch,VSR-M: (65) (330) (460) (53) (143) (213) (388) (111) (32) 1-1/2"(DN40) 91144815 3 13 18-1/16 2-1/16 5-7/8 8-5/8 15-3/4 4-3/8 1-1/4 2"(DN50) 91144802 (80) Groove Groove (330) (460) (53) (150) (219) (400) (111) (32) 2-1/2"(DN65) 91144825 3"(DN80) 91144803 4 Groove Groove 13 20-1/4 4-1/4 6-3/4 10-3/4 18-3/8 5-3/16 2 4"(DN100) 91144804 (100) (330) (514) (108) (172) (273) (467) (132) (50) 6"(0N150) 91144806 6 13 20-1/4 4-1/4 7-3/4 11-3/4 21 6-3/4 2 4 Field Replaceable (150) Groove Groove (330) (514) (108) Retard/Switch 91144800 (197) (300) (533) (172) (50) OUTLET 1 -2� .,/ ) ,I, OPTIONAL ( PRESSURE w;ii i irr RELIEF TRIM c CONNECTION rRw�il _ ,ION I s 3,4 ��, 11214.1 poi I ' / A Ira-al ' 0111 ) IIp, I ii 41 a INLET C MEI G - H D - - E F - FIGURE 1 MODEL RM-1 COMMERCIAL RISER MANIFOLDS 1-1/2-6 INCH(DN4O-DN15O) TFP963 Page 3 of 8 OPTIONAL PRESSURE RELIEF TRIM 1"NPT 1 CONNECTION (FEMALE) IN Awl g tl , I. \ NO DESCRIPTION P/N 1....1 2 • 11" 1 300 psi/2000 kPa 10" Water Pressure Gauge..90050001 LIra (254 m"m) �'- 1 (280 mm) 2 Ball Valve,1"(DN25)....97111803 ii � 3 Flow Switch,VSR-M, IT) semon • 1"(DN25) 91144801 4 Field Replaceable Retard/Switch 91144800 2-1/2" 1" (64 mm) NPT 1111 DRAIN 3-3/4" 3-7/8" (96 mm) y 1"NPT 3,4 (100 mm) 4-5/8" (FEMALE) (118 mm) _ 10-1/8" (257 mm) FIGURE 2 MODEL RM-1 RESIDENTIAL RISER MANIFOLD 1 INCH(DN25) III OPTIONAL PRESSURERELIE 1 ONNFTRIM 1-1/2"FEMNPT CONNECTION (FEMALE) L. -,07., 1 .1' PO& NI sr Nim I, I I *hie* it " 0 - 13-1/4" (337 mm) NO DESCRIPTION P/N 1 1 1 300 psi/2000 kPa 10" "�O Water Pressure Gauge..90050001 ■ (254 mm) ■ 2 Ball Valve,1"(0N25)....97111603 2 3 Flow Switch,VSR-M, iL__'i .� ip 1-1/2"(DN40) 91144815 Anti. 7/16" ��,_� 4 Field Replaceable (11 mm) Retard/Switch 91144800 1� 1 1 3-7/8" 3-7/8" 3,4 (100 mm) 1" (100 mm) 1-1/2"NPT NPT 4-3/4" _ (MALE) DRAIN ~(121 mm) 11-3/8" _i (290 mm) FIGURE 3 MODEL RM-1 RESIDENTIAL RISER MANIFOLD 1-1/2 INCH(DN40) TFP963 Page 4 of 8 II 2" (GROOVED) 1 OPTIONAL �� d� PRESSURE Imo_ O 1>t .y RELIEF TRIM CONNECTION Is 16" .....i. 1 (406 mm) NO DESCRIPTION P/N 13" 1 300 psil2000 kPe (330 mm) I i Water Pressure Gauge..90050001 2 Bell Valve,1"(DN25)....97111603 3 Flow Switch,VSR-M, III 2"(DN50) 91144802 2 ��� 4 Field Replaceable Retard/Switch 91144800 III ejl 1/2" r,_ ii I ' (13 mm) 1 -��� � .a= jl I 3-7/8" 4-1/8" 3,4 (100 mm) 1" (105 mm) 2" NPT _ 5" (GROOVED) DRAIN (127 mm) 11-7/8" (300 mm) FIGURE 4 MODEL RM-1 RESIDENTIAL RISER MANIFOLD 2 INCH(DN50) Manifold Notes: Step 1. Install the manifold body with Where applicable pipe thread sealant the flow arrow pointing in the down- Installation is to be applied sparingly. Use of a stream position using threaded con- non-hardening pipe thread sealant is nections and/or listed mechanical grooved connections,as applicable. TYCO Model RM-1 Riser Manifold recommended. must be installed in accordance with Never remove any piping component Step 2. Connect the drain line and on this section. nor correct or modify any piping defi- commercial manifolds set the Model po o The Model RM-1 Riser Manifold may be ciencies without first depressurizing and Drain Valve to the OFF installed either horizontally(flow switch and draining the system. positionor on residential manifolds on top)or vertically(flow going up).The closreethe drain valve. inlet of the Riser Manifold may be con- Provisions for an alarm test flow on Step 3. Refer to Figure 6 for wiring netted directly to a shut-off control Residential Models must be made. guidance.All wiring must be performed valve. The alarm test flow is to be through in accordance with the authority having an orifice having a flow capacity equal jurisdiction and/or the National Electri- to or smaller than the smallest orifice cal Code. sprinkler in the system. One of two options can be considered. The first Step 4. Refer to Figure 5 for Optional option is to temporarily install a test Pressure Relief Trim installation. orifice in the outlet of the drain line Step 5. Place the system in service prior to performing the alarm test. The by filling the system with water. When second option is to install an lnspec- filling the system, partially open the tor's Test Connection downstream of control valve to slowly fill the system. the Waterflow Alarm Switch. Filling the system slowly will help avoid damaging the waterflow alarm switch. After the system is fully pressurized, completely open the control valve. Step 6.Secure all supply valves open. TFP963 Page 5 of 8 Commercial Riser Manifolds Residential Riser Manifolds NO DESCRIPTION P/N NO DESCRIPTION P/N 1 Pressure Relief Valve, 1 Pressure Relief Valve, 175 psi,1/2"NPT 1001184-01 175 psi,1/2"NPT 1 001 1 84-01 2 1/2"x Close Nipple 1001023-01 MODEL RM-1 2 1/2"x Close Nipple,City 2...1 001 02 3-01 3 Flexible Hose: COMMERCIAL 3 Flexible Hose,1/2"x 16"....1 001 266-03 1-1/2-3 Inch(DN40-DN80) RISER MANIFOLD 4 Figure 815 Threaded Size Manifolds, 2 Reducing Tee, 1/2"x 24" 1001266-02 1 1"x 1"x 1/2"NPT 1001259-07 4-6 Inch(DN100-DN150) 5 1"x Close Nipple 1001025-01 Size Manifolds, _ 1/2"x 30" 1001266-01 Oy 4 Figure 323 Reducing Tee, �` MODEL RM-1 Grooved x NPT Threaded: pp* lleV/ RESIDENTIAL 1-1/2-3 Inch(DN40-DN80) } �'Y;,,t j�r3 "' RISER MANIFOLD Size Manifolds, .. 1-1/4"x 1-1/4"x 1/2" 3231305GS '` � 2 1 Si a ah(old00-DN150) r Size Manifolds, ` I t � f 2"x 2"x 1/2" 3232005GS / ,,..�i � �J 5 Figure 577 Rigid Grooved /"' 6.._ _ Coupling: 3 5 , ��.-e� 1-1/2-3 Inch(DN40-DN80) 4 ,� t.rq o Size Manifolds, `.�, 1-1/4" 57713AGCP `� 3/ fh 4-6 Inch(DN100-DN15O) Size Manifolds, 2 5 I ' 2" 57720AGCP 4 FIGURE 5 MODEL RM-i COMMERCIAL AND RESIDENTIAL RISER MANIFOLDS OPTIONAL PRESSURE RELIEF TRIM INSTALLATION Optional Commercial Manifolds Residential Manifolds Refer to Figure 1 for commercial riser Refer to Figures 2, 3 or 4 for residen- Pressure manifold features and Figure 5 for pres- tial riser manifold features and Figure sure relief trim components described 5 for pressure relief trim components Relief Trim in this procedure. described in this procedure. Installation Step 1. Remove 1/2 in.pipe plug from Step 1. Remove 1/2 in.pipe plug from manifold tee. Inspect exposed female manifold tee. Inspect exposed female Model RM-1 commercial and resi- tee threads, remove thread sealant tee threads, remove thread sealant dential riser manifold assemblies are remnants or debris as necessary. remnants or debris as necessary. designed to accommodate an optional Step 2. Install Pressure Relief Valve(1) Step 2. Install Pressure Relief Valve(1) pressure relief valve and trim compo- in manifold tee, orienting valve outlet in manifold tee, orienting valve outlet nents(Ref.Figure 5). port perpendicular to and facing away port perpendicular to and facing away Optional pressure relief trim must be from manifold body. from manifold body. installed in accordance with the follow- Step 3. Install 1/2 in. x Close Nipple Step 3. Disconnect drain piping from ing procedures. (2)in pressure relief valve outlet port. threaded outlet of manifold drain valve Notes: Step 4. Disconnect drain piping from as applicable and install 1 in. x Close For assembly in Riser Manifolds grooved outlet of manifold TD-1 test Nipple(5)in valve outlet. installed and in service, verify the fire and drain valve as applicable and install Step 4. Install Figure 815 Reducing protection system is de-pressurized Figure 323 Grooved Reducing Tee(4) Tee(4)onto 1 inch x close nipple,align- and drained. Close the system supply on valve outlet by securing with Fig- ing tee branch outlet parallel with pres- control valve,set commercial manifold ure 577 Grooved Coupling (5), align- sure relief valve outlet port.Reconnect test and drain valve to DRAIN or open ing tee threaded branch outlet parallel drain piping to Figure 815 tee drain out- residential drain valve to relieve resid with pressure relief valve outlet port. let as necessary. ual pressure and drain system. Make Reconnect drain piping to Figure 323 Step 5. Install 1/2 in. x Close Nipples certain that drainage water will not tee drain outlet as necessary. (2) in pressure relief valve outlet port cause any damage or injury. Note: Refer to Technical Data Sheet and in Figure 815 reducing tee branch Refer to Care and Maintenance section G901 for Figure 577 Grooved Coupling outlet. installation and assembly for other requirements when closing a instructions. Step 6. Install Flexible Hose (3) by fire protection system control valve and Step 5. Install Flexible Hose (3) by threading female ends onto 1/2 in. x placing system in service. threading female ends onto 1/2 in. x close nipples installed on relief valve Apply thread sealant or TEFLON tape close nipple installed on relief valve outlet port and Figure 815 reducing tee on all threaded connections, with the outlet port and onto Figure 323 reduc- branch outlet. exception of internally sealed flexible ing tee branch outlet. Note:Assure Flexible Hose is not sus- hose connections. Note:Assure Flexible Hose is not sus- ceptible to being caught or snagged by ceptible to being caught or snagged by other moving equipment. other moving equipment. TFP963 Page 6 of 8 SWITCH TERMINAL CONNECTIONS UNINSULATED CLAMPING SEVERED LOOPED SECTION CAUTION: PLATE STRIPPED SINGLE An uninsulated section of a TERMINAL ENDS CONDUCTOR single conductor is not SEPARATE permitted to be looped around .-___i CONDUCTORS CLAMPING the terminal and serve as two /1 PLATE \ separate connections.The TERMINAL wire must be severed to serve \ INCOMING as two separate connections, -,____i thereby providing supervision of the connection in the event that the wire becomes dislodged from the terminal. OUTGOING IMPROPER CONNECTION METHOD PROPER CONNECTION METHOD WIRE NUT LOCAL WIRE NUT FIRE PANEL OR AUDIBLENISUAL ADDRESSABLE ANNUNCIATOR MODULE NEUTRAL WHITE WHITE BLACK \} ri 7 Y CC Omi BLACK �O7¢Oto I— ®� (LINE/HOT) 7 O M O Z a-Z O7Q //O \\ J 0 0 CONTACT RATINGS: 0 0 Two sets of SPDT(Form C) 10.0 Amps at 125/250VAC • - 2.0 Amps at 30VDC Resistive 10 mAmps min.at 24VDC ((��\(�NOy NC COM COM NC (JO \GJ4 CI U CD © ® WhenNOTE connecting to a —1 —= UL Listed control panel, i 1 use panel resistor rating -- for circuit supervision NOTE: For supervised circuits,see"Switch Terminal Connections"above.The Waterflow Alarm Switch has two switches,one can be used to operate a central station,proprietary or remote signaling unit,while the other contact is used to operate a local audible or visual annunciator. FIGURE 6 MODEL RM-1 COMMERCIAL AND RESIDENTIAL RISER MANIFOLD WIRING GUIDANCE TFP963 Page 7 of 8 . —■oRA1N I '0 ■ a' •ii) o o o ■ ■ o yikrio , OFF MARKING TEST MARKING DRAIN MARKING ON HANDLE ON HANDLE ON HANDLE Abi POSITIONED POSITIONED POSITIONED I. ON DETENT ON DETENT ON DETENT III sly 1 T � MODEL i�� � �_ OEAND 'M_ pT IIM MIMI VALVE II - .lam -0 0 I. o 0 o' I i(D 0, I■I II bid kid •' _ SIGHT FLOW a (1=3) ) I El w DRAIN 1111 I CONNECTION SET TEST DRAIN FRONT CONDITION CONDITION CONDITION VIEW FIGURE 7 MODEL RM-1 COMMERCIAL RISER MANIFOLD TD-1 TEST AND DRAIN VALVE OPERATION Care and tion to the standards of any authority of the NFPA,and any impairment must having jurisdiction.Contact the install- be immediately corrected: Maintenance ing contractor or product manufacturer Alarm/Flow Test Procedure with any questions. Step 1.Place the Model TD-1 Test and TYCO Riser Manifolds RM-1 must be It is recommended that automatic Drain Valve in the TEST position (Ref. serviced and maintained in accordance sprinkler systems be inspected,tested, Figure 7). On residential assemblies with this section. and maintained by a qualified Inspec- without a test orifice,temporarily install Before closing a fire protection system tion Service in accordance with local a test orifice in the drain outlet and fully control valve for inspection or main- requirements and/or national codes. open the Drain Valve. Make certain tenance work on the fire protection Note: No attempt is to be made to that drainage water will not cause any system that it controls, permission to repair any Riser Manifold component damage or injury. shut down the effected fire protection in the field. Only the pressure gauge, Step 2.Verify operation of associated system must first be obtained from waterflow alarm switch, or relief valve alarms. the proper authorities and all person- can be replaced.lf any other problems Step 3. Verify that the residual (i.e., nel who may be affected by this action are encountered the entire riser mani- flowing)pressure indicated by the pres- must be notified. fold must be replaced. sure gauge is no less that originally After placing a fire protection system The alarm/flow test procedure will recorded for the system when it was in service,notify the proper authorities result in operation of the associated first installed. and advise those responsible for moni- alarms. Consequently, notification Step 4. Close the Drain Valve on the toring proprietary and/or central station must be given to the owner and the fire Residential models and the Test and alarms. department, central station, or other Drain valve on commercial models. The owner is responsible for the signal station to which the alarms are inspection,testing,and maintenance of connected, and notification must be Step 5. Verify that the static (i.e., not their fire protection system and devices given to the building occupants. flowing)pressure indicated by the pres- in compliance with this document, as The following inspection procedure sure gauge is no less that originally well as with the applicable standards must be performed as indicated, in recorded for the system when it was of the NATIONAL FIRE PROTECTION addition to any specific requirements first installed. ASSOCIATION(e.g.,NFPA 25),in addi- • TFP963 Page 8 of 8 Nominal Equivalent Limited Ordering Valve Size Length of ANSI in.(DN) Schedule Pipe Warranty Procedure fm) 2(DN50) 4.5(1,3) For warranty terms and conditions,visit Contact your local distributor for avail- www.tyco-fire.com. ability. When placing an order, indi- 2-1/2(DN65) 3.6(1,1) cate the full product name, including 3(DN80) 3(5,1) description and part number(P/N). 4(DN100) 4(6,6) Riser Manifolds 6(DN150) 9.6(2,9) Specify:Size(specify)Connection Type (specify inlet x outlet)Model RM-1 Riser TABLE A Manifold,P/N(specify): FRICTION LOSS EXPRESSED Commercial AS FLOW THROUGH 1-1/2 in.(DN40)MT x FT 40551 EQUIVALENT LENGTH OF 2 in.(DN50)G x G 40601 SCHEDULE 40 PIPE 2-1/2 in.(DN65)G x G 40611 3 in.(DN80)G x G 40621 4 in.(DN100)G x G 40651 6 in.(DN150)G x G 40661 Residential 1 in.(DN25)FT x FT 40671 1-1/2 in.(DN40)MT x FT 40571 2 in.(DN50)G x G 40591 Optional 175 psi Pressure Relief Kit Specify: Pressure Relief Kit, Model RM-1 Riser Manifold,(specify Commer- cial or Residential application),(specify size range), P/N(specify): Commercial 1-1/2 in.-3 in.(DN40-DN80) 40721 4in.-6 in.(DN100-DN150) 40731 Residential 1 in.-2 in.(DN25-DN50) 40711 Replacement Parts Specify: Model RM-1 Riser Manifold (specify part description), P/N(specify from Figures 1,2,3,4 or 5) 1400 Pennbrook Parkway,Lansdale,PA 194461 Telephone+1-215-362-0700 / �r o1011 Jobnsdn Controls.All rights nand All specifications and olber information shown were current as of document rwblan date and are subject to change witnout notice. Johnson J �`i NATIONAL FIRE PROTECOON AS0OCLATICN and NEPA regiersnd trademarks otNetlonal Fin PMect.°Aeeocwaon; Controls TER I N strsdenvk a The d,em0ure Coogan s EC.LLC l.1 82 1le erj r DCDA-II BACKFLOW i� t�� A Assembly Check Detectorssemb y DIRECT The Deringer 30(x) Double Check Detector Assembly prevents non-health hazard pollutants from entering a potable water supply system when backpressure and/or backsiphonage conditions occur. V 1.Used primarily on fire sprinkler systems when ' • A,• l P E monitoring of unathorized water use is required. : = " OWN R Sizes: 2%:". 3", 4", 6". 8" % `4. T Working Pressure: 10-175psi(0.7-12.1 bar) rr Temperature Range: 33°-140°F(1°-60°C) C a End Connections A 1 - IPS Groove for Steel Pipe: AWWA C606 HORIZONTAL L k,,,,, - Flange Adapters: ANSI B16.1 Class 125 ULCE CERTIFIED ANS!VI 4L` O USC MAMA i Lead Free: 0.25%Maximum by Weight LEAD FREE • ,., ,„o , „ APPROVED COMPLIANT Lead Free Bronze CuFt or Gallons DCDA II Single Bypass Componets Bypass Meter Check Bypass Integral Shut-Off Valves 1 Indoor/Outdoor Application ,..t Prowired Supervisory v Switches ; 100%Stainless £" Steel Housing + _ ,. ``a.. ,.. . a —° -i Silicone Elastomer -Dual Actionrm Check Modules `M • Check Discs 1 Th •Poppet Action at Low Flow - , ., n :_ •Swing Action at High Flow . N IPS Grooved , Ends Tamper Resistent Test Cocks y.. Flange Adapters `a` Available ,Eagineen ng Speciescations The Deringer 30(x)Double Check Detector Assembly shall utilize two independent Dual Action Check modules and two integral resiliently seated shut-off valves all of which shall be contained within a single rigid valve housing constructed entirely of 304 stainless steel. Both integral shutoff valves shall include pre-wired supervisory tamper switches contained within a weatherproof actuator housing approved for both indoor and outdoor use. Dual Action Check modules shall operate as a"poppet style"check under low flow conditions, operate as a"swing style"check under high flow conditions and utilize replaceable silicone elastomer sealing discs. Assembly test cocks shall be handle-less and operate via a tamper resistant actuator.Assembly shall have a single full access service port and cover with an "inline" replaceable elastomer seal. The bypass assembly shall include a meter registering either gallons or cubic feet, a single check valve and required test cocks. Assembly shall be serviceable without special tools and approved for both horizontal and vertical applications. Job Name: Contractor: Job Location: Approval: Engineer: Contractor's P.O. No: Approval: Representative: Backliow Direct, LLC • 3290 Monier Circle•Rancho Cordova•California•95742• United States of America Phone: 916-760-4524 Website: www.backflowdirect.com F1V A PerfOrMaince (1pm) 379 757 1136 1514 18$3 2271 2650 3028 18 124 P 16 110 a 14 * 2 Y" (30) 3" (30) 4" (30)— 96 y 12 83 J 10 69 m 28 a. 2 0 100 200 300 400 500 600 700 800 C - Rated Flow A - UL Tested 0 - 15 f Rate of Flow (gpm) P s Horizontal Qriantation 3028 4542 8658(i�„Y,, -, 7571 9o85 16 1 1'c y 14 8" (30) 96 812 83 co 10 6" (30x) 69 8 55 a 0 i IkPa) 0 400 800 1200 1600 2000 2400 'Specific orientation&agency flow characteristics ava,loble on website Rate of Flow(gpm) Measures A t ials Honzanta - - sc I Rio" Ht 0 t Ec a Hb t L w Size Model Ht Hb L Ec D H W Weight Sc in mm in mm in mm in mm in mm in mm in min in mm lbs kg NPT 214 65 30 7.1 180 2.9 74 18.7 475 2 'h 65 0.0 0 10.0 254 11.0 279 47 21 V," 3 80 30 7.4 188 2.9 74 18.7 475 3 80 0.0 0 10.3 262 11.0 279 49 22 'A" 4 100 30 7.9 201 3.1 79 18.7 475 4 100 0.2 5 11.0 279 11.0 279 51 23 6 150 30x 8.7 221 4.8 122 28.4 721 6 150 1.0 25 13.5 343 13.8 351 137 62 V, 8 200 30 10.4 264 5.4 137 30.7 780 8 200 1.8 46 15.8 401 13.8 351 150 68 14' Valve Housing: 304 Stainless Steel SOV Bearings: Teflon/Bronze Cheek Springs: 17-7 Stainless Steel Valve Cover: 304 Stainless Steel Non Wetted Bolts:Grade 8 Zinc Plated Cheek Pins: 17-7/18-8 Stainless Steel SOV Disks: EPDM/304SS Wetted Fasteners: 18-8 Stainless Steel Check Seats: Norv!Polymer(NSF) SOV Shafts: 304 Stainless Steel All Check Disks: Silicone(NSF) 0-Rings: &ma-N(NSF) Bypass Spring: 302 Stainless Steel Bypass C'omponents:Lead Free Bronze Bypass Internals: IBS Polymer(NSF) Backflow Direct,LUC • 3290 Monier Circle• Rancho Cordova•California •95742 • United states of America Phone: 916-760-4524 FVebsite: www.backilowdirect.com 0 Oldcastle Precast Delivering Reliability AUBURN 676-LAIWA .....-FuIl`60. Open i f Recessed Lift Handle w ir. 1 1-1-1-1-1- 1-1- m .xxxxx�1 -i--1--1-1-1-1-1-1-1-1 COVER 1-1--1-1-1-1-1-1-1-1-1-1-1- _1=_ No.676-TL-2-332P�, �x xxl�.xxxx '''4'� 4,000 I b s hl •. hI-1-1-1-1-1-h 1-31/2 �, 1-1-hhl-hhl-I --17t.-IV717171-' I-1 1-1-1-1 �F! \ 141, ,,ki p 7-2" ,....,,-,, , ,,,, CENTER ,. /� No. 676-MLW ---� �`; ' 1111114 6,300 Ibs t I. 111 BASE No.676-BL • 5,300 Ibs . 1-3 1/2 IiiiiiiP 9: ,S': .--'"------'-> v Non Skid Covers Available FOR DETAILS,SEE REVERSE» Items Shown Are Subject To Change Without Notice Issue Date:April 2016 23 0 1997-2016 Oldcastle Precast,Inc. Mailing Address Phone:800-892-1538 PO Box 588 Fax:253-735-4201 opauburn.con7 Auburn,WA 98071 Email:opauburn@oldcastle.com I Oldcastle Precast Delivering Reliability 676-LA/WA --iii 7-9" I... .1 V-6" —.-- -.— g" —.— ———3/4" Dia. Lift Insert 4 Places In Top B w/ UV rps I t •• - I iv-- . I I/ 4. I .. 27 i ..:•,,X•Xs:sX•:',X,Z: ,,'„'LI ••;•14We :s•'s' ---M'IMV '1, ;ZZ;*•;,;" "Mt•,''AZX ;Z:Z.."00;Z;:Z;Z"z'Z., f '? . ' •%;;;,:k:-**,:,X,:',' ,:',;;;;;.t;:w:;`,q; g., ua en 1 i . :Z/NfiN44;h:X3141",`./.4.1‘..,,:44:4`eVilViet 1,1%4" .61 in ',a A 6'1A*MS'N'$‘‘$ .‘.i*Zk;0);,,‘/SeZ 1' • '5m,;'si.•,"5,,,,"',A(..*: ",,,,,,k,•,, ,,;;;A.sk 1 6:,Z;IZZ;.i0 elSX'S., '4" 1 b 1 . — L-: 1_ 7 r " 1 • ' 1 I L 2—Ton Lift Anchors •B 1 Each Corner, 4 Corners Spring Assisted Galvanized Diamond Plate Covers PLAN VIEW ./ Locking Latch 506-LA —•=mmmail =====.- T-- :...... -',.'.:.:14 1..!'.....: •:.‘-...:;T:.. 7 N g'li . g-IN in ' — ,..• El 7 =sr= En, ' FIT-1 0 TI_ _:2 I-1-1 - - FID 'T_i ,,. _ ; _ 4 Li 1 , g.t..=.- L L_I t _: LI_I_Om 71-Li_e' ,8 —1 .. •k.v -.. i... .2. 8 •... r n 1 1 . li. Golvanized "C:. Channel, 3.— LD g. o . E.LJ] cv 3 Each Side, 2 Sides 1 :'.i ,,, e. L ___ _ b. '1- i • 1 ' .''? ...A 4 . . -,..... :- i.,..• .: ...... :, ..„,• .::: ::i.:.-.,. 12" Dia. Sump I 1/2" Galvanized Pulling Iron 1 Each Corner. 4 Corners SECTION AA SECTION BB SCALE: 3/8"=1'-0" 23.1 c)1997-2016 Oldcastle Precast,Inc. opauburn.com 1i,cti Worldwide wwwtyco-fire.com Contacts Model K17-231 — 16.8 K-factor Upright and Pendent Sprinklers Standard Response, Standard Coverage 1 General NOTICE The 16.8 K-factor, Model K17-231 Description Upright and Pendent Sprinklers described herein must be installed > 101411 9 The TYCO 16.8 K-factor, Model and maintained in compliance with K17-231, Standard Response, Stan- this document and with the applica- dard Coverage, Upright and Pendent ble standards of the National Fire Pro- Sprinklers(Ref. Figure 1)are automatic tection Association, in addition to the sprinklers of the frangible bulb type. standards of any authorities having They are standard response spray jurisdiction.Failure to do so may impair . sprinklers which produce a hemispheri- the performance of these devices. cal water distribution pattern below the The owner is responsible for main- _ +n.. deflector. taining their fire protection system The 16.8 K-factor, K17-231 Sprinklers and devices in proper operating con- were ;. subjected to full scale,high-piled dition. Contact the installing contrac- storage, fire tests to qualify their use for or product manufacturer with any in lieu of 8.0 or 11.2 K-factor standard questions. spray sprinklers for the protection of . high-piled storage. Sprinkler Higher flow rates can be achieved at much lower pressures with the 16.8 Identification K-factor,K17-231 Sprinklers— making their use highly advantageous in high Number (SIN) density applications, such as the pro- tection of high-piled storage. Refer to Table A for sprinkler identifica- "'' Applications for the 16.8 K-factor, tion numbers. Model K17-231 Pendent and Upright Technical Sprinklers are expanding beyond the current listings/approvals. For infor- Data mation regarding research fire tests which may be acceptable to an author- Approvals ity having jurisdiction, please contact UL and C-UL Listed the Technical Services Department. FM Approved(upright only) NYC Approved TableOperation Refer to Table C for specific details on labo- ratory listings and approvals.The approvals The glass bulb contains a fluid that apply to the service conditions indicated in the Design Criteria section. expands when exposed to heat.When the rated temperature is reached, the Finish Fatural Brass fluid expands sufficiently to shatter the IMPORTANT glass bulb, allowing the sprinkler to Refer to Technical Data Sheet Physical Characteristics activate and flow water. TFP2300 for warnings pertaining to Frame Bronze regulatory and health information. Belton Bronze 9 y Sealing Assembly..Beryllium Nickel w/TEFLON Always refer to Technical Data Bulb(5 mm) Mass Sheet TFP700 for the "INSTALLER Compression Screw Brass Deflector Brass WARNING" that provides cautions with respect to handling and instal- Additional Technical Data lation of sprinkler systems and com- Refer to Table A for additional techni- ponents. Improper handling and cal data. installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 OCTOBER 2021 TFP332 TFP332 Page 2 of 4 1 - Frame 6 if 1 f,A G, 1\ \, 3 - Sefton 5* 3 - Sealing Assembly 4 Bulb 4 (121/27mm ' 1.---.. 5 - Deflector* 3 , ) 2-3/8" 6 - Compression NOMINAL ■ ■ (60,3 mm) Screw 2 MAKE-IN * Temperature rating is W I indicated on deflector. WRENCH 3/4" FLAT NPT CROSS SECTION UPRIGHT PENDENT FIGURE 1 MODEL K17-231 UPRIGHT(TY7151)AND PENDENT(TY7251)SPRINKLERS Design Item Description Criteria TY7151 Sprinkler Identification Number(SIN) TY7251 UL and C-UL Listing Requirements TY7151 is a redesignation for C7151,G1888,and S8040 TY7251 is a redesignation for C7251,G1889,and 58041 The TYCO 16.8 K-factor,Model K17-231 Sprinklers may be installed in accor- K-factor,(gpm/psi)(Ipm/bar) 16.8 gpm/psi^(241,9Ipm/bar°) dance with NFPA 13 standard sprinkler position and area/density flow calcu- 155°F(68°C) lation requirements for light, ordinary, Temperature Rating°F(°C) 200°F(93°C) or extra hazard occupancies with a 286°F(141°C) minimum residual(flowing)pressure of Thread Size 3/4 in.NPT 7 psi(0,5 bar) in wet or dry pipe sprin- kler systems, or they may be installed Sprinkler Orientation Upright and Pendent in accordance with NFPA 13 standard Maximum Working Pressure,psi(bar) 175 psi(12,1 bar) sprinkler position and area/density flow calculation requirements for high Note: piled storage occupancies(solid piled, 1. Rfer to Table C fo laboratory llstinga and approvals. palletized, rack storage, bin box, and TABLE A shelf storage including but not limited MODEL K17-231 UPRIGHT AND PENDENT SPRINKLER to Class I-IV and Group A plastics)with a minimum residual (flowing) pressure TECHNICAL DATA of 7 psi (0,5 bar) for wet or dry pipe systems. • a minimum deflector to top of stor- • a minimum deflector to top of stor- The following two examples are typical age clearance of 18 in.(457 mm); age clearance of 18 in.(457 mm); of the types of arrangements permit- • a minimum design density of 0.60 • a minimum design density of ted by NFPA 13. For all combinations gpm/ft2(24,4 mm/min); 0.80 gpm/ft2(32,6 mm/min); of lesser and greater building heights, • a minimum residual (flowing) pres- • a minimum residual (flowing) lesser and greater storage heights, sure of 7 psi (0,5 bar); pressure of 7 psi(0,5 bar); storage arrangements, commodity classifications, and lesser or greater • a minimum design area of 2000 ft2 • a minimum design area of 2000 ft2 required design densities, refer to (186 m2)for wet systems or 2600 ft2 (186 m2)for wet systems or 4500 ft2 NFPA 13 for specifics. (242 m2)for dry pipe systems (418 m2)for dry pipe systems Example 1: NFPA 13 provides ceiling Example 2: NFPA 13 provides ceiling FM Approval Requirements only protection (that is, no in-rack only protection (that is, no in-rack TheTYCO 16.8 K-factor,Model K17-231 sprinklers) criteria using open frame sprinklers) criteria using open frame (TY7151) Upright Sprinklers may be (that is,no solid shelves)single,double, (that is,no solid shelves)single,double, installed in accordance with the appli- multiple-row, or portable rack storage multiple-row, or portable rack storage cable control mode density/area guide- (without the need for in-rack sprinkler (without the need for in-rack sprinkler lines provided by Factory Mutual. (FM protection) of cartoned unexpanded protection) of cartoned unexpanded guidelines may differ from UL and C-UL Group A or B plastics, or, cartoned Group A or B plastics, or, cartoned Listing criteria.) expanded Group A or B plastics,with: expanded Group A or B plastics,with: • a storage height of up to 20 ft • a storage height of up to 25 ft (6,1 m); (7,6 m); • a maximum ceiling height of 27 ft • a maximum ceiling height of 30 ft (8,2 m); (9,1 m); TFP332 Page 3 of 4 Storage Type NFPA Global (Uprightt Sprinkle Only) Sprinkler Type Standard Coverage Storage Response Type SR SR System Type Wet and Dry Wet and Dry 155°F(68°C) 155°F(68°C1 Temperature Rating°F(°C)r 200°F(93°C) 200°F(93°C) 286°F(141°C) 286°F(141°C) Open Frame (i.e., no solid shelves) Single, Double, Multiple- Row, or Portable Rack Storage of Class I-IV and Group A or Refer to NFPA 13 Refer to FM 2-0 and 8-9 B Plastics Solid Pile or Palletized Storage of Class I-IV and Group A or Refer to NFPA 13 Refer to FM 2-0 and 8-9 B Plastics Idle Pallet Storage Refer to NFPA 13 Refer to FM 2-0,8-9,and 8-24 Rubber Tire Storage Refer to NFPA 13 Refer to FM 2-0 and 8-3 Roll Paper Storage Refer to NFPA 13 Refer to FM 8-21 (Refer to the Standard) Flammable/Ignitable Liquid Storage Refer to NFPA 30 Refer to FM 7-29 (Refer to the Standard) Aerosol Storage Refer to NFPA 30B Refer to FM 7-31 (Refer to the Standard) Automotive Components in Portable Racks Refer to NFPA 13 N/A (Control mode only;refer to the Standard) Notes: 1. Refer to Table C for laboratory listings and approvals. N/A-Not Applicable TABLE B MODEL K17-231 UPRIGHT AND PENDENT SPRINKLERS COMMODITY SELECTION AND DESIGN CRITERIA OVERVIEW TYPE TEMPERATURE BULB SPRINKLER FINISH LIQUID NATURAL BRASS 155°F(68°C) Red UPRIGHT 200°F(93°C) Green 1,2,3,4 K=16.8(TY7151) 286°F(141°C) Blue 155°F(68°C) Red PENDENT 200°F(93°C) Green 1,2,4 K=16.8(TY7251) 286°F(141°C) Blue Notes: 1. Listed by Underwriters Laboratories,Inc.(UL Listed). 2. Listed by Underwriters Laboratories,Inc.for use in Canada(C-UL Listed). 3. Approved by Factory Mutual Research Corporation(FM Approved). 4. Approved by the City of New York under MEA 177-03-E. TABLE C LABORATORY LISTINGS AND APPROVALS (Refer To The Design Criteria Section) TFP332 Page 4 of 4 Care and Limited Maintenance Warranty The TYCO Ultra K17 Sprinklers must be For warranty terms and conditions,visit maintained and serviced in accordance www.tyco-fire.com with this section. N WRENCH Before closing a fire protection system Ordering RECESS main control valve for maintenance procedure work on the fire protection system that it controls,permission to shut down the \\ affected fire protection systems must Contact your local distributor for avail- ability01 be obtained from the proper authorities .When placing an order, indicate � and all personnel who may be affected the full product name and Part Number by this action must be notified. (P/N). FIGURE 2 Sprinklers that are found to be leaking Sprinkler Assemblies with NPT W-TYPE8 or exhibiting visible signs of corrosion Thread Connections SPRINKLER WRENCH must be replaced. Specify: (specify SIN), 16.8 K-factor, Automatic sprinklers must never be Model K17-231, (specify) temperature Installation painted, plated, coated, or other- Sprratiinkler,P/Nf(specify):Pendent or Upright) wise altered after leaving the factory. The TYCO Model K17-231 Sprinklers Modified sprinklers must be replaced. Upright(SIN TY7151) must be installed in accordance with Sprinklers that have been exposed to 155°F(93°C)(68°C 51-888-1-155 this section. corrosive products of combustion, but 200°F 286°F 141C 141°C) 51-888-1-200 51-888-1-286 have not operated,should be replaced Pendent(SIN TY7251) General Instructions if they cannot be completely cleaned 155°F(68°C) 51-889-1-155 A leak tight 3/4 in. NPT sprinkler joint by wiping the sprinkler with a cloth or 200°F(93°C) 51-889-1-200 should be obtained by applying a min- by brushing it with a soft bristle brush. 286°F(141°C) 51-889-1-286 imum-to-maximum torque of 10 to 20 Care must be exercised to avoid Sprinkler Wrench lb-ft (13,4 to 26,8 N•m). Higher levels damage to the sprinklers before, Specify: W-Type 8 Sprinkler Wrench, of torque may distort the sprinkler inlet during, and after installation. Sprin- P/N 56-892-1-001 with consequent leakage or impairment klers damaged by dropping, striking, of the sprinkler. wrench twist/slippage,or the like, must Do not install any bulb type sprinkler be replaced.Also,replace any sprinkler if the bulb is cracked or there is a loss that has a cracked bulb or that has lost of liquid from the bulb.With the sprin- liquid from its bulb. Refer to Installation kler held horizontal, a small air bubble section for additional information. should be present.The diameter of the The owner is responsible for the inspec- air bubble is approximately 1/16 in. tion, testing, and maintenance of their (1,6 mm). fire protection system and devices in Step 1. With pipe thread sealant compliance with this document, as applied to the pipe threads, hand well as with the applicable standards tighten the Model K17-231 Sprinkler of the National Fire Protection Associ- into the sprinkler fitting. ation, such as NFPA 25, in addition to Step 2. Using the W-Type 8 Sprinkler the standards of any other authorities having jurisdiction. Contact the install- Wrench (Ref. Figure 2) applied to the ing contractor or product manufacturer sprinkler Wrench Flats(Ref. Figure 1), with any questions. tighten the Model K17-231 Sprinkler into the sprinkler fitting. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. 1400 Pennbrook Parkway,Lansdale,PA 194461 Telephone+1-215-362-0700 / e2g2d Johnson Controls.All rights reserve[.All specifications and other Information shown were current as of document revision date and are subject to change without italics. Johnson J)),�( �l NATIONAL Floe PROTECTION ASSOCIATION and NFPA ars registered vulvae.of National Fire Prot°°tronhssnclatl°n: Controls TEFLON is a trademark Nt The Chem°ws Company FT.LLC tl.,CL7 Worldwide wwwtyco-fire.com Contacts Model SW-20 and SW-24 — 11.2 K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General not representative of all possible cor- rosive atmospheres. Consequently, Description it is recommended that the end user p be consulted with respect to the suit- '"'- The TYCO Model SW-20 and SW-24, ability of these corrosion resistant iii„ 11.2 K-factor,Extended Coverage Ordi- coatings for any given corrosive envi- nary Hazard (ECOH) Horizontal Side- ronment. The effects of ambient tem- fir// wall Sprinklers, Standard Response perature, concentration of chemicals, and gas/chemical velocity, should be are decorative glass bulb sprinklers SW-20 considered, as a minimum, along with designed for use in ordinary hazard the corrosive nature of the chemical to occupancies per NFPA 13. which the sprinklers will be exposed. The SW-20 provides protection of cov- erage areas up to 16 ft x 20 ft(320 ft2), NOTICE whereas the SW 24 provides protec- The Model SW-20 and SW-24 Sprin- tion of coverage areas up to 16 ft x 24 klers described herein must be installed r ft (384 ft2), as compared to standard and maintained in compliance with this i'`, IV coverage horizontal sidewall sprinklers document and with the applicable stan- having a maximum coverage area of 10 dards of the National Fire Protection ft x 10 ft (100 ft2) for ordinary hazard Association, in addition to the stan- SW-24 occupancies. dards of any authorities having juris- Horizontal sidewall sprinklers are diction.Failure to do so may impair the Maximum Working Pressure designed for installation along a wall performance of these devices. 175 psi(12,1 bar) or the side of a beam and are com- The owner is responsible for maintain- Discharge Coefficient monly used instead of pendent or ing their fire protection system and K= 11.2 GPM/psi'7,(161,3 LPM/bar"°) upright sprinklers due to aesthetics or devices in proper operating condition. Temperature Rating building construction considerations, The installing contractor or sprinkler SW-20: 155°F(68°C)&200°F(93°C) where piping across the ceiling is not manufacturer should be contacted with SW-24:200°F(93°C) desirable. any questions. Finishes Corrosion resistant coatings, where Refer to Table B applicable,are utilized to extend the life Sprinkler Physical Characteristics: of copper alloy sprinklers beyond that Frame Bronze which would otherwise be obtained - - Button Bronze when exposed to corrosive atmo- Identification Sealing Assembly Beryllium p Nickel w/TEFLON spheres. Although corrosion resistant Number (SIN) Bulb Glass coated sprinklers have passed the Compression Screw Brass standard corrosion tests of the appli- TY5332-SW-20 Deflector Bronze cable approval agencies,the testing is TY5337-SW-24 TY5332 is a re-designation for C5332 TY5337 is a re-designation for C5337 IMPORTANT Technical Refer to Technical Data Sheet Data TFP2300 for warnings pertaining to regulatory and health information. Approvals Always refer to Technical Data UL and C-UL Listed Sheet TFP700 for the `INSTALLER (Refer to the Design Criteria Section) WARNING"that provides cautions Polyester coated sprinklers are UL and with respect to handling and instal- C-UL Listed as Corrosion Resistant lation of sprinkler systems and corn- Sprinklers ponents. Improper handling and NYC under MEA 177-03-E installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 AUGUST 2018 TFP230 TFP23O Page 2 of 6 Components: /6* 5 -WRENCH 1 - Frame RECESS 2 Button a (END"B") APPLY 3- Bulb -I WRENCH AS 4- Compression Screw O SHOWN 5- Sealing Assembly 6- Deflector* \ \ --. , *Temperature rating is indicated on Deflector. 4 3 2 1 **Pipe thread connections per ISO 7-1 can be provided CENTERLINE FIGURE 3 on special request. 1/2" OF SPRINKLER WRENCH W-TYPE 3 SPRINKLER (12,7 mm) WATERWAY FLAT WRENCH k 3/4"** NPT f MAXIMUM THROW 2° 1/2°(12,7 mm) \ t NOMINAL — (50,8 mm) MAKE-IN J 6"(152,4 mm) 3/4" f 2-3/8" TO 12"(304,8 mm) (19,1 mm) (60,3 mm) CEILING TO TOP 4/12 FIGURE 1 OF SPRINKLER SLOPE MODEL SW-20(TY5332) DEFLECTOR MAXIMUM EXTENDED COVERAGE ORDINARY HAZARD DISTANCE HORIZONTAL SIDEWALL SPRINKLER FIGURE 4 11.2 K-FACTOR,3/4 INCH NPT SPRINKLER PLACEMENT UNDER SLOPED CEILINGS IN Components: LOADING DOCKS 1 2- Frameo rill_ Operation 3- Bulb .I 4- Compression Screw O ICI The glass bulb contains a fluid that 5- Sealing Assembly °O expands when exposed to heat.When 6- Deflector* \ the rated temperature is reached, the 3/4"** fluid expands sufficiently to shatter the *Temperature rating is *Temperature on Deflector. WRENCH NPT glass bulb, allowing the sprinkler to indicatFLAT activate and water to flow. **Pipe thread connections per ISO 7-1 can be provided CENTERLINE on special request. 9/16" OF SPRINKLER (14,3 mm) WATERWAY 1 5 2 / 6* '`11 / o f \ \( 4 3 2° 1/2"(12,7 mm) (50,8 mm) NOMINAL- - MAKE-IN i 3/4" 2-,3/8" _ _ (19,1 mm)~{ (60,3 mm) FIGURE 2 MODEL SW-24(TY5337) EXTENDED COVERAGE ORDINARY HAZARD HORIZONTAL SIDEWALL SPRINKLER 11.2 K-FACTOR,3/4 INCH NPT TFP230 Page 3 of 6 MODEL SW-20 ECOH HORIZONTAL SIDEWALL SPRINKLER(TY5332) OH Group 1 (0.15 gpm/sq-ft) Coverage Minimum Minimum Deflector-To-Ceiling Sprinkler Minimum Response Area(1), Flow(2), Pressure(2i, Distance(3), Temperature Spacing(4), Rating Ft x Ft(m x m) GPM(LPM) PSI(BAR) In.(mm) Rating,°F Ft(m) Standard 16 x 16(4,9 x 4,9 38(144) 11.5(0,79) 6 to 12(150 to 300) 155,200 8(2,4) Standard 16 x 18(4,9 x 5,5) 43(163) 14.7(1,01) 6 to 12(150 to 300) 155,200 8(2,4) Standard 16 x 20(4,9 x 6,1) 48(182) 18.4(1,27) 6 to 12(150 to 300) 155,200 8(2,4) MODEL SW-20 ECOH HORIZONTAL SIDEWALL SPRINKLER(TY5332) OH Group 2(0.20 gpm/sq.-ft.) Response Coverage Minimum Minimum Deflector-To-Ceiling Sprinkler Minimum Rating Area(1), Flow(2) Pressure(2), Distance(3), Temperature Spacing(4), • Ft x Ft(m x m) GPM(LPM) PSI(BAR) In.(mm) Rating,°F Ft(m) • Standard 16 x 16(4,9 x 4,9 51 (193) 20.7(1,43) 6 to 12(150 to 300) 155,200 8(2,4) Standard _16 x 18(4,9 x 5,5)______58(221_ 26.8(1 85]__ 6 to 12(150 to 300) 155,200 8(2,4) I Standard 16 x 20(4,9 x 6,1) 64(242) 32.7(2,25) 6 to 12(150 to 300) 155,200 8(2,4) MODEL SW-24 ECOH HORIZONTAL SIDEWALL SPRINKLER(TY5337) OH Group 1 (0.15 gpm/sq.-ft.) Response Coverage Minimum Minimum Deflector-To-Ceiling Sprinkler Minimum Rating Area)1), Flow(2), Pressure(2), Distance(3), Temperature Spacing(4), Ft x Ft(m x m) GPM(LPM) PSI(BAR) In.(mm) Rating,°F Ft(m) Standard 16 x 22(4,9 x 6,7) 53(200) 22.4(1,54) 6 to 12(150 to 300) 200 8(2,4) Standard 16 x 24(4,9 x 7,3) 58(220) 26.8(1,85) 6 to 12(150 to 300) 200 8(2,4) MODEL SW-24 ECOH HORIZONTAL SIDEWALL SPRINKLER(TY5337) • OH Group 2(0.20 gpm/sq.-ft.) Response Coverage Minimum Minimum Deflector-To-Ceiling Sprinkler Minimum Rating Area(1), Flow(2) Pressure(°), Distance)3), Temperature Spacing(4), • • Ft x Ft(m x m) GPM(LPM) PSI(BAR) In.(mm) Rating,°F Ft(m) • • Standard 16 x 22(4,9 x 6,7) 71 (269) 40.2(2,77) 6 to 12(150 to 300) 200 8(2,4) Standard 16 x 24(4,9 x 7,3) 77(291) 47,3(3,26) 6 to 12(150 to 300) 200 8(2,4) NOTES 1. Backwall(where sprinkler is located)by sidewall(length of throw). 2. Requirement is based on minimum flow in GPM from each sprinkler.The indicted residual pressures are based on the nominal N-factor. 3. The centerline of the sprinkler waterway is located below the deflector as shown in Figures 1 and 2_ 4_ Minimum spacing is for lateral distance between sprinklers located along a single wall.Otherwise adjacent sprinklers(i.e.,sidewall sprinklers on an adjacent wall,on an opposite wall,or pendent sprinklers)must be located outside of the maximum listed protection area of the extended coverage sidewall sprinkler being utilized_ TABLEA UL AND C-UL LISTING COVERAGE AND FLOW RATE CRITERIA TFP2SO Page 4 of 6 Design Step 2. With pipe thread sealant be replaced. Also, replace any sprin- applied to the pipe threads, hand klerthat has a cracked bulb or that has Criteria tighten the sprinkler into the sprinkler lost liquid from its bulb. (Ref. Installa- fitting. tion Section). The TYCO Model SW-20 and SW-24, Step 3. Tighten the sprinkler into the Frequent visual inspections are rec- 11.2 K-factor,Extended Coverage Ordi- sprinkler fitting using only the W-Type ommended to be initially performed nary Hazard (ECOH) Horizontal Side- 3(End B)Sprinkler Wrench(Ref.Figure for corrosion resistant coated sprin- wall Sprinklers are for use in ordinary 3). With reference to Figures 1 and 2, klers, after the installation has been hazard occupancies with non-combus- the W-Type 3 Sprinkler Wrench is to be completed,to verify the integrity of the tible unobstructed construction and applied to the sprinkler wrench flats corrosion resistant coating.Thereafter, with a ceiling slope not exceeding 2 annual inspections per NFPA 25 should inches per foot(9.2°),using the design Care and suffice;however,instead of inspecting criteria provided in Table A, (as well from the floor level,a random sampling as any additional requirements speci- Maintenance of close-up visual inspections should fied in NFPA 13 for Extended Coverage be made,so as to better determine the Sidewall Spray Sprinklers). The TYCO Model SW-20 and SW-24, exact sprinkler condition and the long A 36 in. (914 mm) clearance must be 11.2 K-factor,Extended Coverage Ordi- term integrity of the corrosion resistant maintained between the top of the nary Hazard (ECOH) Horizontal Side- coating as it may be affected by the sprinkler deflector and any miscella- wall Sprinklers must be maintained corrosive conditions present. neous storage. and serviced in accordance with this section. The SW-20 and SW-24 may be installed Before closingafireprotection system on sloped ceilings in loading docks withY a maximum roof slope of 4 in.per foot main control valve for maintenance (18.4°)as shown in Figure 4 and using work on the fire protection system the design criteria provided in Table A. that it controls, obtain permission to shut down the affected fire protec- The SW-20 and SW-24 can be used tion system from the proper authorities only for exposed applications. The and notify all personnel who may be SW-20 and SW-24 cannot be recessed. affected by this action. Installation The owner is responsible for the inspection,testing,and maintenance of The TYCO Model SW-20 and SW-24, their fire protection system and devices 11.2 K-factor,Extended Coverage Ordi- in compliance with this document, as nary Hazard (ECOH) Horizontal Side- well as with the applicable standards wall Sprinklers must be installed in of the National Fire Protection Asso- accordance with this section. ciation (e.g., NFPA 25), in addition to the standards of any other authorities General Instructions having jurisdiction.Contact the install- Do not install any bulb type sprinkler ing contractor or sprinkler manufac- if the bulb is cracked or there is a loss turer regarding any questions. of liquid from the bulb.With the sprin- klerAutomatic sprinkler systems should be ho ldld horizontally,ntT a small air bubble inspected,tested,and maintained bya should be present.The diameter of the P air bubble is approximately 1/16 in.(1,6 qualified Inspection Service in accor- 1 mm). dance with local requirements and/or national code. l A leak tight 1/2 in. NPT sprinkler joint Absence of an escutcheon, which is should be obtained with a minimum to used to cover a clearance hole, may torque of 7 to 14 lb-ft (9,5 to 19,0 N•m). Higher levels of torque delay the time to sprinkler operation in can distort the sprinkler Inlet with con- a fire situation. sequent leakage or impairment of the Automatic sprinklers must never be sprinkler. painted, plated, coated or other- Do not attempt to compensate for wise altered after leaving the factory. insufficient adjustment in the Sprinkler Modified sprinklers must be replaced. by under-or over-tightening the Sprin- Sprinklers that have been exposed to kler/Support Cup Assembly.Re-adjust corrosive products of combustion,but the position of the sprinkler fitting to have not operated,should be replaced suit. if they cannot be completely cleaned by wiping the sprinkler with a cloth or Step 1. Horizontal sidewall sprinklers by brushing it with a soft bristle brush. are to be installed with their center- Care be exercised to avoid line perpendicular to the back wall and Care must to the sprinklers s before, parallel to the ceiling.The word TOP on the deflector is to face towards the during, and after installation. Sprin- ceiling. klers damaged by dropping, striking, wrench twist/slippage,or the like,must TFP230 Page 5 of 6 P/N 51 - XXX - X - XXX I I SPRINKLER SPRINKLER MODEL SIN FINISH TEMPERATURE RATING 072 Model SW-20 TY5332 1 Natural Brass 155 155°F(68°C) (SW-20 Only) 073 Model SW-24 TY5337 4 Signal White(RAL9003) 200 200°F(93°C) Polyester (SW-20 or SW-24) 9 Chrome Plated TABLE B MODEL SW-20 AND SW-24 ECOH HORIZONTAL SIDEWALL SPRINKLERS WITH 3/4 INCH NPT CONNECTION PART NUMBER SELECTION Limited Warranty For warranty terms and conditions,visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indi- cate the full product name and Part Numbers(P/N). Sprinkler Assemblies with NPT Thread Connections: Specify: Model (specify) ECOH Hori- zontal Sidewall Sprinkler,SIN(specify), (specify) temperature rating, (specify) finish, P/N(specify from Table B) Sprinkler Wrench: Specify: W-Type 3 Sprinkler Wrench, P/N 56-895-1-001 tq , co Worldwide Contacts www.tyco-fire.com Series TY-FRB - 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick and Standard Response (Light Hazard) General wall position, or a two-piece Style 20 (1/2 in. NPT) or Style 30 (3/4 in. NPT) Description Recessed Escutcheon with 1/4 in. (6,4 f 5 p mm) of recessed adjustment or up to e�`"" TYCO Series TY-FRB 5.6 and 8.0 1/2 in. (12,7 mm) of total adjustment ..1, _ K-factor Extended Coverage Hori- from the flush sidewall position. The zontal Sidewall Sprinklers Quick and adjustment provided by the Recessed ;;: ° Standard Response(Light Hazard)are Escutcheon reduces the accuracy to decorative 3 mm glass bulb type spray which the fixed pipe lengths to the A sprinklers designed for use in hydrau- must be cut. lically calculated sprinkler systems in Corrosion resistant coatings, where light hazard, commercial occupancies applicable,are utilized to extend the life such as churches, restaurant seating of copper alloy sprinklers beyond that areas, hotels, educational facilities, which would otherwise be obtained offices, etc. With their coverage up when exposed to corrosive atmo- to 16 ft (4,9 m) wide by 24 ft (7,3 m) spheres. Although corrosion resistant long,they are designed for installation coated sprinklers have passed the along a wall or the side of a beam and standard corrosion tests of the appli- i di.0111 just beneath a smooth ceiling. Hori- cable approval agencies,the testing is ♦: zontal sidewall (HSW) sprinklers are not representative of all possible cor- commonly used instead of pendent or rosive atmospheres. Consequently, upright sprinklers due to aesthetics or it is recommended that the end user building construction considerations, be consulted with respect to the suit- where piping across the ceiling is not ability of these coatings for any given desirable. corrosive environment. The effects of Sprinkler The fast response thermal sensitivity ambient temperature,concentration of rating of the Series TY-FRB,3 mm bulb chemicals, and gas/chemical velocity, Identification type sprinklers provides fora quick should be considered, as a minimum, response extended coverage (OREC) along with the corrosive nature of the Numbers (SINS) rating for many of the coverage areas chemical to which the sprinklers will be detailed in Tables B and C. exposed. TY3332...EC HSW, 5.6K, 1/2 in. NPT The recessed version of the Series TY4332. ..EC HSW,8.0K,3/4 in. NPT TY-FRB Extended Coverage Horizontal NOTICE Sidewall Sprinkler utilizes either a two- The Series TY-FRB Sprinklers piece Style 10 (1/2 in. NPT) or Style described herein must be installed 40 (3/4 in. NPT) Recessed Escutch- and maintained in compliance with this eon with 1/2 in. (12,7 mm) of recessed document, as well as with the applica- adjustment or up to 3/4 in. (19,1 mm) ble standards of the National Fire Pro- of total adjustment from the flush side- tection Association(NFPA),in addition to the standards of any other authori- ties having jurisdiction.Failure to do so IMPORTANT may impair the performance of these Refer to Technical Data Sheet devices. TFP2300 for warnings pertaining to The owner is responsible for main- regulatory and health information. taining their fire protection system Always refer to Technical Data and devices in proper operating con- Sheet TFP700 for the "INSTALLER dition. Contact the installing contrac- WARNING" that provides cautions for or product manufacturer with any with respect to handling and instal- questions. lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 AUGUST 2018 TFP296 TFP296 Page 2 of 8 ComponentsFrame DEFLECTOR 4 ■T echnical 2 - Button HAT ` l Data 3 - Sealing Assembly 4 - Bulb Approvals 5 - Compression Screw UL and C-UL Listed 6 - Deflector* / FM and NYC Approved 7 Ejection Spring (Refer to Table A for complete approval infor- 6* 5 2 3 1 mation including corrosion resistant status, *Temperature rating is indicated as well as the Design Criteria section per- on Deflector or adjacent to orifice WRENCH taining to special design considerations.) seat on Frame. 7 FLATS 1/2"** Maximum Working Pressure II�� NPT Refer to Table B. =ri 7 7/16"(11,1 mm) l Discharge Coefficient / K=5.6 gpm/psi1'2(80,6 Ipm/bar1'2) K=8.0 gpm/psi1'2(115,2lpm/bar1'2) 4 1 ";'" i / "� j Temperature Ratings 1-9/16" CENTERLINE Refer to Table A. OF SPRINKLER 7/16" (39,7mm) WATERWAY (11,1 mm) — Finishes NOMINAL Sprinkler:Refer to Table E. MAKE-IN Recessed Escutcheon:White Coated, **Pipe thread connections per Chrome Plated,or Brass Plated ISO 7-1 can be provided on 1-1/2 special request. �(38,1 mm)� FFramelcal Characteristics Bronze 7/16" 2�/16" Button Brass/Copper - Button Brass/Copper (11,1 mm) (55,6 mm) Sealing Assembly..Beryllium Nickel w/TEFLON FIGURE 1 Bulb Glass SERIES TY-FRB(TY3332) Compression Screw Bronze EXTENDED COVERAGE Deflector Copper HORIZONTAL SIDEWALL SPRINKLER Operation 5.6 K-FACTOR, 1/2 INCH NPT r The glass bulb contains a fluid which expands when exposed to heat.When Components DEFLECTOR the rated temperature is reached, the 1 - Frame HAT ` - 4 fluid expands sufficiently to shatter the 2 - Button glass bulb, allowing the sprinkler to 3 Sealing Assembly \ activate and water to flow. 4 - Bulb 5 - Compression Screw - Design 6 - Deflector* / 7 Ejection Spring 6* 5 2 3 \1 Criteria *Temperature rating is indicated TYCO Series TY-FRB 5.6 and 8.0 on Deflector or adjacent to orifice WRENCH ** K-factor Extended Coverage Horizon- seat on Frame. 7 FLATS 3/4° tal Sidewall Sprinklers Quick and Stan- NPT dard Response(Light Hazard)must be � installed and utilized in Light Hazard 7/16"(11,1 mm) I IIIIIII Occupancies, under smooth ceilings ®D _ as outlined in the appliable installation ; standard recognized by the Approval t / �\-.....,,„.. Agency (e.g., UL recognizes NFPA 13, 1 1 1/2„ CENTERLINE and FM recognize the FM Loss Preven- OF SPRINKLER 1/2" tion Data Sheets). Only the Style 10, (38,1 mm) WATERWAY (12,7 mm) 20,30,or 40 Recessed Escutcheon,as i NOMINAL applicable, is to be used for recessed MAKE-IN installations. **Pipe thread connections per 1-1/2" ISO 7-1 can be provided on r(38,1 mm)~ special request. 9/16" 2-1/4" (14,3 mm) (57,2 mm) FIGURE 2 SERIES TY-FRB (TY4332) EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER 8.0 K-FACTOR, 3/4 INCH NPT TFP296 Page 3 of 8 SPRINKLER TEMPERATURE BULB SPRINKLER FINISH(5) K-FACTOR TYPE RATING LIQUID NATURAL CHROME COLOR BRASS PLATED POLYESTERe 5.6 135°F(57°C) Orange 1/2 in. EC HSW 155°F(68°C) Red 1,2,3,4 NPT (TY3332) 175°F(79°C) Yellow 135°F(57°C) Orange 5.6 RECESSED EC HSWa 1/2 in. (TY3332) 155°F(umRed 1,2,4 NPT 175°F(79°C) Yellow 135°F(57°C) Orange 1/2 n RECESSED EC HSWb 155°F(68°C) Red 1,2,3,4 NPT (TY3332) 175°F(79°C) Yellow 135°F(57°C) Orange 8.0 3/4 i EC HSW 155°F(68°C) Red 1,2,3,4 NPT (TY4332) 175°F(79°C) Yellow 135°F(57°C) Orange 1,2,4 8.0 in. RECESSED EC NSW155°F(66°C) Red 3/4 NPT (TY4332) 175°F(79°C) Yellow 1,2,3,4 135°F(57°C) Orange 3/4.0 RECESSED EC HSWb 155°F(68°C) Red 1,2,3,4 NPT (TY4332) 175°F(79°C) Yellow Notes: 1. Listed by Underwriters Laboratories,Inc.(UL)per Table C • 2. Listed by Underwriters Laboratories,Inc.for use in Canada per Table C 3. Approved by Factory Mutual Research Corporation(FM)per Table D 4. Approved by the City of New York under MEA 354-01-E 5. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed corrosion-resistant sprinklers. a. Installed with Style 10(1/2 In.NPT)or Style 40(3/4 in.NPT)3/4 in.Total Adjustment Recessed Escutcheon.as applicable b. Installed with Style 20(1/2 in.NPT)or Style 30(3/4 in.NPT)1/2 in.Total Adjustment Recessed Escutcheon,as applicable c. Frame and deflector only TABLE A LABORATORY LISTINGS AND APPROVALS (Refer to the Design Criteria Section) SPRINKLER SPRINKLER FINISH K-FACTOR TYPE NATURAL CHROME BRASS PLATED POLYESTER EC HSW 5.6 (TY3332) 1/2 in. 250 PSI(17,2 BAR) NPT RECESSED EC HSW OR (TY3332) 175 PSI(12,1 BAR) EC HSW 8.0 (TY4332) 3/4 in. (SEE NOTE 1) NPT RECESSED EC HSW (TY4332) Notes: 1. The maximum working pressure of 250 psi(17,2 bar)only applies to the Listing by Underwriters Laboratories,Inc.(UL);the Listing by Underwriters Laboratories,Inc.for use in Canada(C-UL);and,the Approval by the City of New York. TABLE B MAXIMUM WORKING PRESSURE TFP296 Page 4 of 8 5.6K EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER(TY3332) Response Coverage Minimum Minimum Deflector-to-Ceiling Sprinkler Minimum Rating Area((, Flow(2), Pressure(), Distance), Temperature Spacing(41, ft x ft(m x m) gpm(Ipm) psi(bar) Inches(mm) Rating,°F ft(m) Quick 16 x 16(4,9 x 4,9) 26(98) 21.6(1,48) 4 to 12(100 to 300) 135,155,175 10(3,1) Quick 16 x 18(4,9 x 5,5) 29(110) 26.8(1,85) 4 to 12(100 to 300) 135,155,175 10(3,1) Quick 16 x 20(4.9 x 6,1) 32(121) 32.7(2,25) 4 to 6(100 to 150) 135 10(3,1) Quick 16 x 22(4,9 x 6,7) 35(133) 39.1 (2,70) 4 to 6(100 to 150) 135 10(3,1) Standard 16 x 20(4,9 x 6,1) 32(121) 32.7(2,25) 4 to 6(100 to 150) 155 10(3,1) Standard 16 x 22(4,9 x 6,7) 35(133) 39.1 (2,70) 4 to 6(100 to 150) 155,175 10(3,1) 8.0K EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER(TY4332) Res Coverage Minimum Minimum Deflector-to-Ceiling Sprinkler Minimum Rating Area(1), Flow(2l, Pressure), Distance), Temperature Spacing(4), ft x ft(m x m) gpm(Ipm) psi(bar) Inches(mm) Rating,°F ft(m) Quick 16 x 16(4,9 x 4,9) 26(98) 10.6(0,73) 4 to 12(100 to 300) 135,155, 175 10(3,1)/13(4,0)(5) Quick 16 x 18(4,9 x 5,5) 29(110) 13.1 (0,90) 4 to 12(100 to 300) 135,155,175 10(3,1)/13(4,0)(5) Quick 16 x 20(4.9 x 6,1) 32(121) 16.0(1,10) 4 to 6(100 to 150) 135 10(3,1)/13(4,0)(5) Quick 16 x 20(4.9 x 6,1) 33(125) 17.0(1,17) 4 to 12(100 to 300) 135 10(3,1)/13(4,0)(51 Quick 16 x 22(4,9 x 6,7) 35(133) 19.1 (1,32) 4 to 6(100 to 150) 135 10(3,1)/13(4,0)(51 Quick 16 x 22(4,9 x 6,7) 36(136) 20.3(1,59) 4 to 12(100 to 300) 135 10(3,1)/13(4,0)(5) Quick 16 x 24(4,9 x 7,3) 39(148) 23.8(1,64) 4 to 6(100 to 150) 135 10(3,1)/13(4,0)(5) Quick 16 x 24(4,9 x 7,3) 40(151) 25.0(1,72) 4 to 12(100 to 300) 135 10(3,1)/13(4,0)(5) Standard 16 x 20(4.9 x 6,1) 32(121) 16.0(1,10) 4 to 6(100 to 150) 155 10(3,1)/13(4,0)(5) Standard 16 x 20(4.9 x 6,1) 33(125) 17.0(1,17) 4 to 12(100 to 300) 155 10(3,1)/13(4,0)(5) Standard 16 x 22(4,9 x 6,7) 35(133) 19.1 (1,32) 4 to 6(100 to 150) 155,175 10(3,1)/13(4,0)(5) Standard 16 x 22(4,9 x 6,7) 36(136) 20.3(1,59) 4 to 12(100 to 300) 155,175 10(3,1)/13(4,0)(5) Standard 16 x 24(4,9 x 7,3) 39(148) 23.8(1,64) 4 to 6(100 to 150) 155,175 10(3,1)/13(4,0)(5) Standard 16 x 24(4,9 x 7,3) 40(151) 25.0(1,72) 4 to 12(100 to 300) 155,175 10(3,1)/13(4,0)(5) Notes: 1. Rockwall(where sprinkler is located)by sidewall(length of throw) 2. Requirement is based on minimum flow in gpm from each sprinkler.The indicted residual pressures are based on the nominal K-factor. 3. The centerline of the sprinkler waterway Is located 7/16 in.(11,1 mm)below the deflector(Ref.Figures 1 and 2). 4. Minimum spacing is for lateral distance between sprinklers located along a single wall,otherwise adjacent sprinklers(i.e.,sidewall sprinklers on an adjacent wall,on an oppo- site wall,or pendent sprinklers)must be located outside of the maximum listed protection area of the extended coverage sidewall sprinkler being utilized. 5. Minimum spacing is 13 ft(4,0 m)when design pressure exceeds 175 psi(12,1 bar),otherwise the minimum spacing is 10 ft(3 m). TABLE C UL AND C-UL LISTING COVERAGE AND FLOW RATE CRITERIA TFP296 Page 5 of 8 5.6K EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER(TY3332) Response Coverage Minimum Minimum Deflector-to-Ceiling Sprinkler Minimum Rating Arealtl, Flow(2), Pressurel2), Distance(3), Temperature Spacing(4), • ft x ft(m x m) gpm(Ipm) psi(bar) Inches(mm) Rating,°F ft(m) Quick 16 x 16(4,9 x 4,9) 26(98) 22(1,51) 4 to 12(100 to 300) 135,155 10(3,1) Quick 16 x 18(4,9 x 5,5) 30(114) 29(2,00) 4 to 12(100 to 300) 135,155 10(3,1) Quick 16 x 20(4.9 x 6,1) 33(125) 35(2,41) 4 to 12(100 to 300) 135,155 10(3,1) Standard 16 x 16(4,9 x 4,9) 26(98) 22(1,51) 4 to 12(100 to 300) 175 10(3,1) Standard 16 x 20(4,9 x 6,1) 30(114) 29(2,00) 4 to 12(100 to 300) 175 10(3,1) Standard 16 x 22(4,9 x 6,7) 33(125) 35(2,41) 4 to 12(100 to 300)) 175 10(3,1) 8.0K EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER(TY4332) Coverage Minimum Minimum Deflector-to-Ceiling Sprinkler Minimum Response C Rating Arealtr Flow(21, Pressure(2), Distance(3) Temperature Spacingl4i, ftx ft(m x m) gpm(Ipm) psi(bar) Inches(mm) Rating,°F ft(m) Quick 16 x 16(4,9 x 4,9) 32(121) 16(1,10) 4 to 12(100 to 300) 135,155 10(3,1) Quick 16 x 18(4,9 x 5,5) 36(136) 20(1,38) 4 to 12(100 to 300) 135,155 10(3,1) Quick 16 x 20(4.9 x 6,1) 40(151) 25(1,72) 4 to 12(100 to 300) 135,155 10(3,1) Quick 16 x 22(4,9 x 6,7) 44(167) 30(2,06) 4 to 12(100 to 300) 135,155 10(3,1) • Quick 16 x 24(4,9 x 6,7) 48(182) 36(2,48) 4 to 12(100 to 300) 135,155 10(3,1) • Standard 16 x 16(4,9 x 4,9) 32(121) 16(1,10) 4 to 12(100 to 300)) 175 10(3,1) Standard 16 x 18(4,9 x 5,5) 36(136) 20(1,38) 4 to 12(100 to 300) 175 10(3,1) Standard 16 x 20(4.9 x 6,1) 40(151) 25(1,72) 4 to 12(100 to 300)) 175 10(3,1) Standard 16 x 22(4,9 x 6,7) 44(167) 30(2,06) 4 to 12(100 to 300) 175 10(3,1) Standard 16 x 24(4,9 x 6,7) 48(182) 36(2,48) 4 to 12(100 to 300) 175 10(3,1) Notes: 1. Backwall(where sprinkler is located)by sidewall(length of throw) 2. Requirement is based on maintaining both minimum flow and minimum residual pressure. 3. The centerline of the sprinkler waterway is located 7/16 in.(11,1 mm)below the deflector(Ref.Figures 1 and 2). 4. Minimum spacing is for lateral distance between sprinklers located along a single wall,otherwise adjacent sprinklers(i.e.,sidewall sprinklers on an adjacent wall,on an oppo- site wall,or pendent sprinklers)must be located outside of the maximum listed protection area of the extended coverage sidewall sprinkler being utilized. TABLE D FM COVERAGE AND FLOW RATE CRITERIA TFP296 Page 6 of 8 Series TY-FRB EC mission to shut down the affected fire Sidewall Sprinkler protection system must be obtained The Series TY-FRB EC Sidewall Sprin- from the proper authorities and all per- RENCH RECESS W 7klers must be installed in accordance sonnel who may be affected by this (END"A"USED FOR with the following instructions: action must be notified. t/2" NPT MODELS) Step 1. Horizontal sidewall sprinklers The owner must assure that the sprin- are to be installed with their center- klers are not used for hanging of any \ line perpendicular to the back wall and objects; otherwise, non-operation in WRENCH RECESS parallel to the ceiling.The word"TOP" the event of a fire or inadvertent oper- (END N3"UREC FOR on the deflector is to face towards the ation may result. 3/4"NPT MODELS) ceiling. Absence of an escutcheon, which is FIGURE 3 Step 2. With pipe thread sealant used to cover a clearance hole, may W-TYPE 6 applied to the pipe threads, hand delay the time to sprinkler operation in SPRINKLER WRENCH tighten the sprinkler into the sprinkler a fire situation. fitting. Sprinklers that are found to be leaking Step 3. Tighten the sprinkler into the or exhibiting visible signs of corrosion WRENCH sprinkler fitting using only the W-Type must be replaced. RECESS 6 Sprinkler Wrench (Ref. Figure 3). \ With reference to Figures 1 and 2,the Automatic sprinklers must never be W-Type 6 Sprinkler Wrench is to be painted, plated, coated or other- wise altered after leaving the factory. applied to the sprinkler wrench flats. Modified sprinklers must be replaced. Series TY-FRB Recessed EC Sprinklers that have been exposed to Sidewall Sprinkler corrosive products of combustion,but 1.01 The Series TY-FRB Recessed EC have not operated,should be replaced Sidewall Sprinklers must be installed if they cannot be completely cleaned in accordance with the following by wiping the sprinkler with a cloth or PUSH WRENCH instructions: by brushing it with a soft bristle brush. IN TO ENSURE ENGAGEMENT Step 1. Horizontal sidewall sprinklers Care must be exercised to avoid WITH SPRINKLER are to be installed with their center- damage to the sprinklers before, WRENCHING AREA line perpendicular to the back wall and during, and after installation. Sprin- FIGURE 4 parallel to the ceiling.The word"TOP" klers damaged by dropping, striking, W-TYPE 7 RECESSED on the deflector is to face towards the wrench twist/slippage,or the like,must SPRINKLER WRENCH ceiling. be replaced.Also,replace any sprinkler that has a cracked bulb or that has lost Step 2.After installing the Style 10,20, Installation 30, or 40 Mounting Plate, as applica - ble,over the sprinkler threads and with tion Section.) TYCO Series TY-FRB 5.6 and 8.0 pipe thread sealant applied to the pipe Frequent visual inspections are rec- K-factor Extended Coverage Horizon- threads,hand tighten the sprinkler into ommended to be initially performed tal Sidewall Sprinklers Quick and Stan- the sprinkler fitting. for corrosion resistant coated sprin- dard Response (Light Hazard) must Step 3. Tighten the sprinkler into the klers, aftere , the installationifythe integrity n has ofhe be installed in accordance with this sprinkler fitting using only the W-Type completed,resistantto vaty the coating.Thereafter,Th the section. 7 Recessed Sprinkler Wrench (Ref. corrosionnualn rNFPA 5 should Figure 4). With reference to Figure 1 annual inspections per 25 should Do not install any bulb type sprinkler suffice; however, instead of inspecting or 2,the W-Type 7 Recessed Sprinkler if the bulb is cracked or there is a loss from the floor level,a random sampling of liquid from the bulb.With the sprin- Wrench is to be applied to the sprinkler of close-up visual inspections should kler held horizontally,a small air bubble wrench flats. be made,so as to better determine the should be present.The diameter of the Step 4.After the wall has been installed exact sprinkler condition and the long air bubble is approximately 1/16 in. or the finish coat has been applied, term integrity of the corrosion resistant (1,6 mm). slide on the Style 10, 20, 30, or 40. coating, as it may be affected by the A leak tight 1/2 inch NPT sprinkler joint Closure over the Series TY-FRB Sprin- corrosive conditions present. kler and push the Closure over the should be obtained with a torque of The owner is responsible for the 7 to 14 lb-ft (9,5 to 19,0 N•m).A leak Mounting Plate until its flange comes inspection,testing,and maintenance of tight 3/4 in. NPT sprinkler joint should in contact with the wall. their fire protection system and devices be obtained with a torque of 10 to Care and in compliance with this document, as 20 lb-ft(13,4 to 26,8 N•m).Higher levels well as with the applicable standards of torque may distort the sprinkler inlet of the National Fire Protection Asso- and cause leakage or impairment of the Maintenance ciation (e.g., NFPA 25), in addition to sprinkler. TYCO Series TY-FRB 5.6 and 8.0 the standards of any other authorities install- Do not attempt to make-upfor insuf- having jurisdiction.Contact the P K-factor Extended Coverage Horizon- ing contractor or product manufacturer ficient adjustment in the escutcheon tal Sidewall Sprinklers Quick and Stan- with any questions.It is recommended plate by under- or over-tightening the dard Response(Light Hazard)must be that automatic sprinkler systems be sprinkler. Readjust the position of the maintained and serviced in accordance inspected, tested, and maintained by sprinkler fitting to suit. with this section. Before closing a fire a qualified Inspection Service in accor- protection system main control valve dance with local requirements and/or for maintenance work on the fire pro- national codes. tection system that it controls, per- TFP296 Page 7 of 8 5/8t1/4" -.. 1/2t1/8" (15,9±6,4 mm) (12,7±3,2 mm) FACE OF FACE OF MOUNTING MOUNTING SURFACE SPRINKLER SURFACE ----- _--- SPRINKLER FITTING FITTING (ll i llllll9 CLOSURE , 1 CLOSURE , 1 2-7/8"DIA. 2-7/8"DIA. (73,0 mm) (73,0 mm) SERIESSERIES TY-FRB EC 2-1/4"DIA. TY-FRB EC 2-1/4"DIA J (57,2 mm) (57,2 mm) MOUNTING " , + MOUNTING PLATE ii ���\�'I ----_..--- 't PLATE I I`) 111 1/8" 1/8" y (3,2 mm) y (3,2 mm) 1-1/4"(31,8 mm) 3/4"(19,1 mm) 1-1/4'(31,8 mm) 1/2°(12,7 mm) 3/4"(19,1 mm) 1/4'(6,4 mm) 1"(25,4 mm) _ _ 1/4"(6,4 mm) FIGURE 5 FIGURE 6 SERIES TY-FRB RECESSED EC SIDEWALL SERIES TY-FRB RECESSED EC SIDEWALL SPRINKLER ASSEMBLY WITH TWO-PIECE SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACOTR, 1/2 INCH NPT 5.6 K-FACTOR, 1/2 INCH NPT 5/8±1/4" _ 1/2t1/8" -� (15,9t6,4 mm) -� (12,7±3,2 mm) FACE OF FACE OF MOUNTING SPRINKLER MOUNTING SPRINKLER SURFACE -- = FITTING SURFACE --- FITTING flllllV lllllll CLOSURE I CLOSURE 1 2-7/8" DIA. 2-7/8'DIA. SERIES (73,0 mm) SERIES (73,0 mm) TY-FRB EC 2-1/4"DIA. TY-FRB EC 2-1/4"DIA. (57,2 mm) (57,2 mm) MOUNTING MOUNTING aPLATE 11)1ll PLATE I'll 1 1/8' r I 1/8" (3,2 mm) (3,2 mm) 1-1/4"(31,8 mm) 3/4"(19,1 mm) 1-1/4"(31,8 mm) 1 112"(12,7 mm) 3/4'(19,1 mm) 1/4"(6,4 mm) 1"(25,4 mm) 1/4'(6,4 mm) FIGURE 7 FIGURE 8 SERIES TY-FRB RECESSED EC SIDEWALL SERIES TY-FRB RECESSED EC SIDEWALL SPRINKLER ASSEMBLY WITH TWO-PIECE SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT 1/2 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR,3/4 INCH NPT 8.0 K-FACTOR,3/4 INCH NPT TFP296 Page 8 of 8 57 - XXX - X - XXX SPRINKLER FINISH 1 NATURAL BRASS TEMPERATURE SIN 3 PURE WHITE(RAL9010) RATING POLYESTER 135 135°F(57°C) 376 5.6K EC HSW TY3332 4 SIGNAL WHITE(RAL9003) 155 155°F(68°C) 396 8.0K EC HSW TY4332 POLYESTER 175 175°F(79°C) 5 JET BLACK(RAL9005) POLYESTER 9 CHROME PLATED TABLE E SERIES TY-FRB EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLERS PART NUMBER SELECTION Limited Warranty For warrany terms and conditions,visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability.When placing an order,indicate the full product name and Part Number (P/N). Sprinkler Assembly with NPT Thread Connections Specify:Series TY-FRB, (specify SIN), Extended Coverage Horizontal Side- wall Sprinkler, K=(specify), (specify) temperature rating,(specify)finish, P/N (specify from Table E) Recessed Escutcheon Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify°) finish, P/N(specify') *Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 1400 Pennbrook Parkway,Lansdale,PA 194461 Telephone.1-215-362-0700 /J (/ o 2011 J0hn.un contl.ro All rights reserved.All specifications and ether information shown were current as of documentravlslon date and era'usherette change wXNnut notice. Johnson - k`1' NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are regia[erw I,etlaina,Ya of National Fira Pr EldienReaocia:ion; Controls TEFLON IS a,pia,ned dad.ma„at Dupont ` 1'L' tlIC17 Worldwide Contacts wwwtyco-fire.com Series TY-FRB - 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General of copper alloy sprinklers beyond that which would otherwise be obtained Description when exposed corrosive atmo- spheres. Although h corrosion resistant • The Series TY-FRB,5.6 K-factor, Hori- coated sprinklers have passed the zontal and Vertical Sidewall Sprinklers standard corrosion tests of the appli- described in this data sheet are quick cable approval agencies,the testing is f 47 •` ` ,r,�+ r response -standard coverage, dec- not representative of all possible tor- 47 1� orative 3 mm glass bulb type spray rosive atmospheres. Consequently, sprinklers designed for use in light and it is recommended that the end user ordinary hazard, commercial occu be consulted with respect to the suit- panties such as banks, hotels, shop- ability of these coatings for any given 1 f ping malls, etc. They are designed for corrosive environment. The effects of installation along a wall or the side of ambient temperature,concentration of a beam and just beneath a smooth chemicals, and gas/chemical velocity, ceiling. Sidewall sprinklers are corn- should be considered, as a minimum, monly used instead of pendent or along with the corrosive nature of the upright sprinklers due to aesthetics or chemical to which the sprinklers will be building construction considerations, exposed. where piping across the ceiling is notk desirable. NOTICE The recessed version of the Series The Series TY-FRB Sprinklers TY-FRB Horizontal Sidewall Sprinkler described herein must be installed ` is intended for use in areas with a fin- and maintained in compliance with ished wall. It uses a two-piece Style this document, as well as with the 10 Recessed Escutcheon with 1/2 in. applicable standards of the National ". (12,7 mm)of recessed adjustment or up Fire Protection Association,in addition to 3/4 in.(19,1 mm)of total adjustment to the standards of any other authori- t.# from the flush sidewall position, or a ties having jurisdiction.Failure to do so two-piece Style 20 Recessed Escutch- may impair the performance of these eon with 1/4 in. (6,4 mm) of recessed devices. adjustment or up to 1/2 in. (12,7 mm) The owner is responsible for main- of total adjustment from the flush side- tainin their fireprotection system 9 Y wall position.The adjustment provided and devices in proper operating con- by the Recessed Escutcheon reduces dition. Contact the installing contrac- Technical the accuracy to which the fixed pipe tor or product manufacturer with any nipples to the sprinklers must be cut. questions. Data Corrosion resistant coatings, where applicable,are utilized to extend the life SprinklerApprovals UL and C-UL Listed Identification FM Approved IMPORTANT LPCB Approved Refer to Technical Data Sheet Numbers NYC Approved TFP2300 for warnings pertaining to (Refer to Table A for complete approval regulatory and health information. TY3331 Horizontal information including corrosion resistant Always refer to Technical Data TY3431 Vertical status.) Sheet TFP700 for the "INSTALLER Maximum Working Pressure WARNING" that provides cautions Refer to Table B with respect to handling and instal- Discharge Coefficient lation of sprinkler systems and corn- K=5.6 GPM/psi112(80,6 LPM/bar112) ponents. Improper handling and installation can permanently damage Temperature Ratings a sprinkler system or its compo- Refer to Table A nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 JULY 2018 TFP176 TFP176 Page 2 of 6 DEFLECTOR DEFLECTOR 1 - Frame HAT � 5 1 - Frame HAT 5 2 - Button - 2 - Button 3 Sealing 3 - Sealing Assembly Assembly 4 - Bulb 4 - Bulb 5 - Compression 5 - Compression Screw Screw 6 - Deflector* 6* 4 2 3 1 6 - Deflector* 6* 4 2 3 1 9/16" WRENCH 1/2"** 9/16" WRENCH 1/2" (14,3 mm) FLATS NPT (14,3 mm) FLATS NPT i \ I \ I 'VOLT �I // 1-13/16" 7/16" 1-13/16" 7/16" (46,0 mm) (11,1 mm) i• (46,0 mm) (11,1 mm) CENTERLINE NOMINAL CENTERLINE NOMINAL OF SPRINKLER MAKE-IN OF SPRINKLER MAKE-IN WATERWAY 11/2" WATERWAY 1-1/2" --.--(38,1 mm)—"- -.--(38,1 mmi ESCUTCHEON ESCUTCHEON PLATE SEATING r 2-3/16" ._ PLATE SEATING 2-3/16" SURFACE - (55,6 mm) SURFACE -_ (55,6 mm) STYLE 10 or 20 1 STYLE 10 f �i RECESSED RECESSED ESCUTCHEON ESCUTCHEON—'"—_� *Temperature rating is / 'Ohl *Temperature rating is / AN. indicated on Deflector 1p IfN�' indicated on Deflector ** Pipe thread connections 1441 ' �,�IIIIIIIIIIII� tI :ill 11 —' IIIII�I�V per ISO 7-1 can be YYY��I provided on special request 2-7/8"DIA. 2-7/8"DIA. (73,0 mm) (73,01 mm) I 1 ALL FINISHES EXCEPT POLY-STAINLESS POLY-STAINLESS FINISH ONLY FIGURE 1 5.6 K-FACTOR QUICK RESPONSE SERIES TY-FRB HORIZONTAL SIDEWALL(TY3331)SPRINKLERS Finishes Poly-Stainless Design Sprinkler:Refer to Table C Physical Characteristics Recessed Escutcheon:Signal or Pure Frame Bronze White,Jet Black,GreyAluminum,Chrome Button L316 Stainless Steels Criteria Bulb Glass Plated,or Brass Plated Compression Screw L316 Stainless Steel" The Series TY-FRB, 5.6 K-factor, Hor- HSWPhysical Characteristics Deflector Copper/Bronze izontal and Vertical Sidewall Sprin- Frame Bronze Sealing Assembly.Gold Plated Beryllium Nickel klers are intended for fire protection Button Brass/Copperw/TEFLON "Type L316 stainless steel(UNS 31663)perASTM systems designed in accordance with Sealing Assembly..Beryllium Nickel w/TEFLON A479/479M or RS EN 1008 WN14404. the standard installation rules rec- Bulb Glass ognized by the applicable Listing or Compression Screw Bronze Operation Approval agency (e.g., UL Listing is HSW Deflector Bronze g enc VSW Deflector Copper Theglass bulb contains a fluid which based on the requirements of NFPA 13, and FM Approval is based on the expands when exposed to heat.When requirements of FM's Loss Prevention the rated temperature is reached, the Data Sheets). Only the Style 10 or 20 fluid expands sufficiently to shatter the Recessed Escutcheon, as applicable, glass bulb, allowing the sprinkler to is to be used for recessed horizontal activate and water to flow. installations. TFP176 Page 3 of 6 Installation *Temperature ** Pipe thread 1 - Frame 4 - Bulb 7 - Ejection rating is connections 2 - Button 5 - Compression Spring The Series TY-FRB,5.6 K-factor,Hori- indicated on per ISO 7-1 can 3 - Sealing Screw zontal and Vertical Sidewall Sprinklers Deflector. be provided on Assembly 6 - Deflector* must be installed in accordance with special request. this section. ARROW MUST General Instructions POINT AWAY /< Do not install any bulb type sprinkler 7/16" FROM AND BE C.)if the bulb is cracked or there is a loss ESCUTCHEON (11,1 mm) PERPENDICULAR of liquid from the bulb.With the sprin- PLATE SEATING ** NOMINAL TO THE BACK kler held horizontally,a small air bubble SURFACE NPT MAKE-IN WALL SURFACE 7 should be present.The diameter of the air bubble is approximately 1/16 in. _I f 6* (1,6I/ 3 3 in. for the 135°F 286°F °F °C) to(141°C) 1 ' 3/32 in.(2,4 mm)for the 286°F(141 C) 6 temperature ratings. FLOW �— A leak tight 1/2 in. NPT sprinkler joint 2-3/16" 2-3/16" 4 should be obtained with a torque of (55,6 mm) . (55,6 mm) 7 to 14 lb-ft (9,5 to 19,0 N•m). Higher 1 1/2" \ � 2 levels of torque may distort the sprin- � (38,1 mm) WRENCH kler and cause leakage or impairment FLATS 7 3 of the sprinkler. -- Do not attempt to make-up for insuf- 1 ficient adjustment in the escutcheon SHOWN SHOWN CROSS plate by under-or over-tightening the PENDENT UPRIGHT SECTION sprinkler. Readjust the position of the sprinkler fitting to suit. FIGURE 2 5.6 K-FACTOR QUICK RESPONSE Series TY-FRB Horizontal and SERIES TY-FRB VERTICAL SIDEWALL(TY3431)SPRINKLERS Vertical Sidewall Sprinkler Installation Series TY-FRB Recessed The Series TY-FRB Horizontal and Horizontal Sidewall Sprinkler Care and Vertical Sidewall Sprinklers must be Installation installed in accordance with the fol- The Series TY-FRB Recessed Horizon- lowing Maintenance instructions. tal Sidewall Sprinklers must be installed Step 1. Horizontal sidewall sprinklers in accordance with this section. The Series TYVertical-FRB, id5. all Sprinklers klers are to be installed in the horizontal zontal and nSidewall Sprinklern position with their centerline of water- Step A. Recessed horizontal sidewall must be maintained and serviced in sprinklers are to be installed in the hori- accordance with this section. way perpendicular to the back wall and zontal position with their centerline of parallel to the ceiling.The word"TOP" Before closing a fire protection system on the Deflector is to face towards the waterway perpendicular to the back main control valve for maintenance wall and parallel to the ceiling. The work on the fire protection system that ceiling. word"TOP"on the Deflector is to face Vertical sidewall sprinklers are to be towards the ceiling. it controls,permission to shut down the installed in the pendent or upright affected fire protection system must be position with the arrow on the Deflec- Step B.After installing the Style 10 or obtained from the proper authorities tor pointing away from the wall. 20 Mounting Plate over the sprinkler and all personnel who may be affected threads,hand tighten the sprinkler into by this action must be notified. Step 2. With pipe thread sealant the sprinkler fitting. Absence of an escutcheon, which is applied to the pipe threads, hand Step C. Tighten the sprinkler into the used to cover a clearance hole, may tighten the sprinkler into the sprinkler sprinkler fitting using only the W-Type delay the time to sprinkler operation in fitting. 7 Recessed Sprinkler Wrench (Ref. a fire situation. Step 3. Tighten the sprinkler into the Figure 6). With reference to Figure Sprinklers that are found to be leaking sprinkler fitting using only the W-Type 1, the W-Type 7 Recessed Sprinkler or exhibiting visible signs of corrosion 6 Sprinkler Wrench(Ref.Figure 5),With Wrench is to be applied to the sprin- must be replaced. reference to Figure 1 or 2,the W-Type kler wrench flats. 6 Sprinkler Wrench is to be applied to Step D. After the ceiling has been Automatic sprinklers must never be the wrench flats. installed or the finish coat has been painted, plated, coated or other- wise altered after leaving the factory. applied, slide on the Style 10 or 20 Closure over the Series TY-FRB Sprin- Modified sprinklersthhave must be exrepposed to kler and push the Closure over the Sprinklers r dt cs combustion,een e but Mounting Plate until its flange comes corrosivev products ofh but in contact with the ceiling. have not operated,should belreplacedle if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during,and after installation.Spriklers TFP176 Page 4 of 6 5/8±1/4" (15,9±6,4 mm) /1 MOUNTING FACE OF WRENCH RECESS SURFACE --- SPRINKLER (END'A"USED FOR FITTING 1/2"NPT MODELS) FIGURE 5 CLOSURE r W-TYPE 6 SPRINKLER WRENCH 2-7/8"DIA. SERIES (73,0 mm) TY-FRB 2-1/4"DIA. WRENCH (57,2 mm) RECESS MOUNTING PLATE - ice- -- 1/8„ 1111111 (3,2 mm) PUSH WRENCH 1-1/4"(31,8 mm) 3/4"(19,1 mm) INTO ENSURE 3/4"(19,1 mm) 1/4"(6,4 mm) ENGAGEMENT FIGURE 3 WITH SPRINKLER WRENCHING AREA SERIES TY-FRB RECESSED HORIZONTAL SIDEWALL SPRINKLER FIGURE 6 WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON W-TYPE 7 RECESSED - -- SPRINKLER WRENCH 1/2±1/8" y ~ (12,7±3,2 mm) MOUNTING FACE OF SURFACE ----_ _- SPRINKLER FITTING CLOSURE 1 2-7/8"DIA. (73,0 mm) SERIES TY-FRB 2-1/4"DIA. (57,2 mm) MOUNTING PLATE ' i 1/8" (3,2 mm) 1-1/4"(31,8 mm) 1/2'(12,7 mm) 1" (25,4 mm) 1/4"(6,4 mm) FIGURE 4 SERIES TY-FRB RECESSED HORIZONTAL SIDEWALL SPRINKLER WITH TWO-PIECE 1/2/NCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFP176 Page 5 of 6 SPRINKLER FINISH(See Note 11) K TYPE TEMP. BULB NATURAL CHROME POLYESTER° POLY- LEAD LIQUID BRASS PLATED STAINLESS° COATED 135°F(57°C) Orange HORIZ. 155°F(68°C) Red SIDEWALL 175°F(79°C) Yellow 1,2,3,4,9,10 1,2,3,9 1,2 1,2,3,9 (TY3331) 200°F(93°C) Green • 286°F(141°C) Blue 5.6 RECESSED 135°F(57°C) Orange 1/2 in. HORIZ. 155°F(68°C) Red NPT SIDEWALL 1,2,4,9,10 1,2,9 1,2 N/A (TY3331)a 175°F(79°C) Yellow Figure 3 200°F(93°C) Green RECESSED 135°F(57°C) Orange HORIZ. 155°F(68°C) Red SIDEWALL 1,2,3,4,9 N/A N/A (TY333i)b 175°F(79°C) Yellow Figure 4 200°F(93°C) Green VERTICAL 135°F(57°C) Orange SIDEWALL 155°F(68°C) Red 5.6 (TY3431) 1/2 in. Installed 175°F(79°C) Yellow 5,6,7,8,9 N/A 5,6,7,9 NPT Pendell or 200°F(93°C) Green Upright 286°F(141°C) Blue NOTES: 1. Listed by Underwriters Laboratories,Inc.(UL)as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies at a 4 to 12 in.(100 to 300 mm)top of deflec- tor to ceiling distance. 2. Listed by Underwriters Laboratories Inc.for use in Canada(C-UL)as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies at a 4 to 12 in.(100 to 300 mm)top of deflector to ceiling distance. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers for use in Light Hazard Occupancies at a 4 to 12 in.(100 to 300 min)top of deflector to ceiling distance. 4. Approved by the Loss Prevention Certification Board(LPCB Ref.No.007a/04)at a 4 to 6 in.(100 to 150 mm)top of deflector to ceiling distance.The LPC does not rate the thermal sensitivity of horizontal sidewall sprinklers. 5. Listed by Underwriters Laboratories,Inc.as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies. 6. Listed by Underwriters Laboratories for use in Canada(C-UL)as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies. 7. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers for use in Light Hazard Occupancies. 8. Approved by the Loss Prevention Certification Board(LPCB Ref.No.D94a/06&007a/04)as Quick Response Sprinklers. 9. Approved by the City of New York under MEA 354-01-E. 10.Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/06)at a 4 to Bin.(100 to 150 tern)top of deflector to ceiling distance.The LPC does not rate the thermal sensitivity of horizontal sidewall sprinklers. 11.Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and G-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as Corrosion Resistant Sprinklers. a. Installed with Style 10(1/2 in.NPT)3/4 in.Total Adjustment Recessed Escutcheon. b. Installed with Style 20(1/2 in.NPT)1/2 in.Total Adjustment Recessed Escutcheon. c. Frame and deflector only. TABLE A LABORATORY LISTINGS AND APPROVALS damaged by dropping,striking,wrench Thereafter, annual inspections per ing contractor or product manufacturer twist/slippage, or the like, must be NFPA 25 should suffice; however, with any questions. replaced. Also, replace any sprikler instead of inspecting from the floor It is recommended that automatic that has a cracked bulb or that has lost level, a random sampling of close-up sprinkler systems be inspected,tested, • liquid from its bulb. (Ref. Installation visual inspections should be made, so and maintained by a qualified Inspec- Section). as to better determine the exact sprin- tion Service in accordance with local The owner must assure that the sprin- kler condition and the long term integ- requirements and/or national codes. riklers are not used for hanging any as it may be affected by the corrosi of the corrosion resistant e objects and that the sprinklers are only conditions present. cleaned by means of gently dusting with a feather duster; otherwise, non- The owner is responsible for the operation in the event of a fire or inad- inspection,testing,and maintenance of • vertent operation may result. their fire protection system and devices Frequent visual inspections are rec- in compliance with this document, as ommended to be initially performed well as with the applicable standards for corrosion resistant coated sprin- cof the National Fire Protection Asso- o klers, after the installation has been the (dad of anyA 25),other in addition utit is • completed, to verify the integrity the standards of authorities of the corrosion resistant coating. having jurisdiction.Contact the install- TFP176 Page 6 of 6 SPRINKLER FINISH K TYPE NATURAL BRASS CHROME PLATED POLYESTER LEAD COATED HORIZONTAL SIDEWALL(TY3331) 250 PSI or BAR) Dr 5.6 175PSI(12,1 BAR) 1/2 in. RECESSED HORIZ. NPT SIDEWALL(TY3331) (SEE NOTE 1) VERTICAL SIDEWALL(TY3431) 175 PSI(12,1 BAR) NOTES: 1. The maximum working pressure of 250 psi(17.2 bar)only applies to the Listing by Underwriters Laboratories.Inc.(UL);the Listing by Underwriters Laboratories,Inc.for use in Canada(C-UL);and,the Approval by the City of New York. TABLE B MAXIMUM WORKING PRESSURE P/N57 — XXX — X — XXX I I SIN SPRINKLER TEMPERATURE FINISH RATINGS 378 HORIZONTAL SIDEWALL TY3331 1 NATURAL BRASS 135 135°F(57°C) 375 VERTICAL SIDEWALL TY3431 POLY-STAINLESS GREY 155 155°F(68°C) 2 ALUMINUM(RAL9007)1 POLYESTER 175 175°F(79°C) 3 PURE WHITE(RAL9010)2 POLYESTER SIGNAL WHITE(RAL9003) 200 200°F(93°C) 4 POLYESTER JET BLACK(RAL9005)3 286 286°F(141°C) 5 POLYESTER 7 LEAD COATED 9 CHROME PLATED NOTES: 1. Available for TY3331 only. 2. Eastern Hemisphere sales only. 3. Available in 155°F(68°C)or 200°F(93°C temperature rating only. TABLE C PART NUMBER SELECTION SERIES TY-FRB HORIZONTAL AND VERTICAL SIDEWALL SPRINKLERS Limited OrderingRecessed Escutcheon Specify: Style (10 or 20) Recessed Warranty Procedure Escutcheon with (specify") finish, P/N (specify') For warranty terms and conditions,visit Contact your local distributor for avail- 'Refer to Technical Data Sheet TFP770 www.tyco-fire.com ability.When placing an order,indicate Sprinkler Wrench the full product name and Part Number Specify: W-Type 6 Sprinkler Wrench, (P/N). P/N 56-000-6-387 Sprinkler Assemblies with NPT Specify: W-Type 7 Sprinkler Wrench, Thread Connections: P/N 56-850-4-001 Specify:Series TY-FRB(specify SIN), (specify K-factor),(specify)Horizontal Sidewall or Vertical Sidewall Sprinkler, Standard Response,Standard Coverage,(specify)temperature rating,(specify)finish or coating, P/N (specify from Table C) 1400 Pennbrook Parkway,Lansdale,PA 19446I Telephone+1-215-362-0700 Art, 02016 Johnsen Controls.All rights reserved.All specifications and other information Mown were current es of document revision date end are subject to ce,enge without notice. Johnson e, NpiIONPL FIRE PROTECTION p550ClA ION and NFFAare rcgltuOd tracemuMe of Nelianai Fire Protectlan Iucocieo°n: Controls TERAN Is a registaec tndemak cf DuPont 1 1l tilccl Worldwide www.tyco-fire.com contacts Series TY-FRB - 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General to corrosive atmospheres. Although corrosion-resistant coated sprinklers z , ,�,r #,, Description have passed the standard corrosion tests of the applicable approval agen 1 I The TYCO Series TY-FRB 2.8,4.2,5.6, ties, the testing is not representative ,, I and 8.0 K-factor Upright, Pendent, of all possible corrosive atmospheres. Consequently, it is recommended that j and Recessed Pendent Sprinklers the end user be consulted with respect , y C..described in herein are quick response, to the suitability of these coatings for , ;-, standard coverage, decorative 3 mm „7 glass bulb-type spray sprinklers.They any given corrosive environment. The R. are designed for use in light or ordinary effects of ambient temperature, con- hazard,commercial occupancies such centration of chemicals, and gas/ as banks, hotels,and shopping malls. chemical velocity, should be consid- ered,as a minimum,along with the cor- The TY-FRB Recessed Pendent Sprin- rosive nature of the chemical to which kler, where applicable, is intended for the sprinklers will be exposed. use in areas with a finished ceiling.This An intermediate level version of the w recessed pendent sprinkler uses one of Series TY-FRB Pendent Sprinklers ' the following Recessed Escutcheons: is detailed in Technical Data Sheet t oz. !$.=" • A two-piece Style 10 (1/2 in. NPT) TFP356. Sprinkler Guards are detailed or Style 40 (3/4 in. NPT) Recessed in Technical Data Sheet TFP780. Escutcheon with 1/2 in.(12,7 mm)of recessed adjustment or up to 3/4 in. NOTICE (19,1 mm) of total adjustment from the flush pendent position. The Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, Sprinkler • A two-piece Style 20 (1/2 in. NPT) and Recessed Pendent Sprinklers 11 or Style 30 (3/4 in. NPT) Recessed described herein must be installed Identification Escutcheon with 1/4 in. (6,4 mm) of and maintained in compliance with recessed adjustment or up to 1/2 in. this document and with the applicable Number (SIN) (12,7 mm) of total adjustment from standards of the National Fire Protec- the flush pendent position. tion Association(NFPA), in addition to TY1131 . ..Upright 2.8K,1/2 in. NPT The adjustment provided by the the standards of any authorities having TY1231 . . Pendent 2.8K,1/2 in.NPT Recessed Escutcheon reduces the jurisdiction. Failure to do so may impair TY2131 .. .Upright 4.2K,1/2 in.NPT accuracy to which the fixed pipe drops the performance of these devices. TY2231 .. Pendent 4.2K, 1/2 in.NPT to the sprinklers must be cut. The owner is responsible for maintain- TY3131 .. .Upright 5.6K, 1/2 in.NPT Corrosion-resistant coatings, where ing their fire protection system and TY3231 . . Pendent 5.6K,1/2 in.NPT applicable, are utilized to extend the devices in proper operating condition. TY4131 . ..Upright 8.0K,3/4 in. NPT life of copper alloy sprinklers beyond The installing contractor or sprinkler TY4231 . . Pendent 8.0K,3/4 in. NPT what would be obtained when exposed manufacturer should be contacted with any questions. TY4831 . . .Upright 8.0K,1/2 in. NPT IMPORTANT NFPA 13 prohibits installation of 1/2 in. TY4931 . . Pendent 8.0K,1/2 in. NPT Refer to Technical Data Sheet NPT sprinklers with K-factors greater Technical TFP2300 for warnings pertaining to than 5.6 in new construction. They are regulatory and health information. intended for retrofit in existing sprinkler Data systems only. Always refer to Technical Data Approvals Sheet TFP700 for the "INSTALLER UL and C-UL Listed WARNING"that provides cautions FM,LPCB,and NYC Approved with respect to handling and instal- lation of sprinkler systems and corn- See Tables A, B, C and D for complete Improper and approval information including corrosion- ponents. handling resistant status. installation can permanently damage a sprinkler system or its compo- Maximum Working Pressure nents and cause the sprinkler to fail See Table E to operate in a fire situation or cause it to operate prematurely. Page 1 of 12 DECEMBER 2020 TFP171 TFP171 Page 2 of 12 *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 7 - Bushing _ _ ._..-- i / 7 rrrrT P—T—'T-TT,t Y = ?toolAl� , 1 7/i6° NOMINAL 111 II 2-1/4' ���` . 3 r 2 MAKE-IN (57,2 mm) I __ 2 3/16' (55,6 mm) iii 1-9/16" 4, 4 . (39,7 mm) . 'r' S rc //fa1�� 6yf,��� r7v� .V>s,-6* 1/2"NPT** f WRENCH STYLE 10 or 20 2-7/8'(73,0 mm)DIA. FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY1131)AND PENDENT(TY1231)SPRINKLERS 2.8 K-FACTOR, 1/2 IN. NPT *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 8 - Deflector* SURFACE 1 W g 7,1 mm) __________. 014 (11,1 mm) II I NOMINAL 2-3/16' '��� 2 MAKE-IN I 4 ii (55,6 mm) �1� �1 2-3/16' 1-1/2' l (55,6 mm) (38,1 mm) II II -5 1 6* 1/2'NPT** WRENCH STYLE 10 or 20 I- 2-7/8'(73,0 mm)DIA. - FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY2131)AND PENDENT(TY2231)SPRINKLERS 4.2 K-FACTOR, 1/2 IN.NPT Discharge Coefficient Poly-Stainless Design K=2.B GPM/psi%(40,3 LPM/bar%) Physical Characteristics K=4.2 GPM/psi%(60,5 LPM/bar%) Frame Bronze Criteria GPM/psi%(80,6 LPM/bar%) Button L316 Stainless Steel' Criteria K=8.0 GPM/psi%(115,2 LPM/bar%) Bulb Glass Compression Screw L316 Stainless Steel' The TYCO Series TY-FRB 2.8,4.2,5.6, Temperature Rating Deflector Copper/Bronze and 8.0 K-factor Upright, Pendent, See Tables A and B Sealing Assembly.Gold Plated Beryllium Nickel and Recessed Pendent Sprinklers are w/TEFLON Finishes 'Type L316 stainless steel(UNS31603)per ASTM intended for fire protection systems Sprinkler:See Table D A479/479M or BS EN 1008 WN1.4404. designed in accordance with the stan- Recessed Escutcheon:Signal or Pure White, dard installation rules recognized by ,Jet Black,Chrome Plated, Operation the applicable Listing or Approval Grey Aluminum, or Natural Brass agency, such as UL Listing based on The glass bulb contains a fluid that the requirements of NFPA 13 and FM Physical Characteristics expands when exposed to heat.When Approval based on the requirements Frame Bronze the rated temperature is reached, the of the FM Global Loss Prevention Data Button Sealing Assembly..Beryllium Nickel ss/Coper w/TEopON fluid expands sufficiently to shatter the Sheets.Use only the style 10,20,30,or Bulb Glass glass bulb, allowing the sprinkler to 40 Recessed Escutcheon, as applica- Compression Screw Bronze activate and water to flow. ble,for recessed pendent installations. Deflector Copper/Bronze Bushing(K=2.8) Bronze TFP171 Page 3 of 12 *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on 2 - Button Assembly Screw Deflector. special request. ESCUTCHEON 4 - Bulb 6 - Deflector* PLATE SEATING SURFACE �G rmr, . ,moo - 0 p 1 7/16° I / 0 3 (11,1 mm) >< ��� � MAKE-IN NOMINAL 2-3/16" ' '.��`� �� 2 1 (55,6 mm) I TO 4 2-3/16" ��� 1-1/2' (55,6 min) (38,1 mm) 1 $71--------5 6* 1/2"NPT** I WRENCH STYLE 10 or 20 r 2-7/8'(73,0 mm)DIA. - FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION ALL FINISHES EXCEPT POLY-STAINLESS WRENCH 1/2" ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated SURFACE 4 - Bulb 6 - Deflector* on Deflector. �Wi \\ _- /_ __, 1 elli Pi 7/16" / i 3 11,1 mm) NOMINAL I 2-3/16" - g , 2 MAKE-IN (55,6 mm) �, I 1�� 2-3/16' 1-1/2' ,II 4 (55,8 mm) (38,1 min) I ' t=- 5 ems- Alt!:.-- 6* f STYLE 10 2-7/8"(73,0 mm)DIA. - RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION POLY-STAINLESS FINISH ONLY FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY3131)AND PENDENT(TY3231)SPRINKLERS 5.6 K-FACTOR, 1/2 IN.NPT Installation of the sprinkler.Do not attempt to corn- Series TY-FRB Recessed Pendent pensate for insufficient adjustment in Sprinklers The TYCO Series TY-FRB 2.8,4.2,5.6, the escutcheon plate by under-or over- The Series TY-FRB Recessed Pendent and 8.0 K-factor Upright, Pendent,and tightening the sprinkler. Re-adjust the Sprinklers must be installed in accor- Recessed Pendent Sprinklers must position of the sprinkler fitting to suit. dance with the following instructions: be installed in accordance with this Series TY-FRB Upright and Pendent Step 1.After installing the Style 10,20, section. Sprinklers 30, or 40 Mounting Plate, as applica- General Instructions The Series TY-FRB Upright and ble,over the sprinkler threads and with Do not install any bulb type sprinkler Pendent Sprinklers must be installed pipe-thread sealant applied to the pipe if the bulb is cracked or there is a loss in accordance with the following threads,hand-tighten the sprinkler into of liquid from the bulb.With the sprin- instructions: the sprinkler fitting. kler held horizontally,a small air bubble Step 1.Install pendent sprinklers in the Step 2. Tighten the sprinkler into the should be present.The diameter of the pendent position. Install upright sprin- sprinkler fitting using only the W-Type 7 air bubble is approximately 1/16 in. klers in the upright position. Recessed Sprinkler Wrench,see Figure (1,6 mm) for the 135°F (57°C) and Step 2. With pipe thread sealant 15. With reference to Figure 1 to 4, 3/32 in. (2,4 mm)for the 286°F(141°C) applied to the pipe threads, hand- apply the W-Type 7 Recessed Sprinkler temperature ratings.A leak-tight 1/2 in. Wrench to the sprinkler wrench flats. NPT sprinkler joint should be obtained tighten the sprinkler into the sprinkler by applying a minimum-to-maximum fitting. Step 3.After the ceiling is installed or torque of 7 to 14 lb-ft(9,5 to 19,0 N•m). Step 3. Tighten the sprinkler into the the Stylefin10,sh 20,coa is applied,40d, loslise on the A leak tight 3/4 in. NPT sprinkler joint sprinkler fitting using only the W-Type 6 the Series 20. 30,RB or Recessed Closure doent should be obtained with a torque of Sprinkler Wrench(Ref.Figure 14).With the nlrd push hCloer Pendent 10 to 20 lb-ft(13,4 to 26,8 N•m).Higher reference to Figure 1 to Figure 5,apply Sprinkler and push•the Closure over the levels of torque can distort the sprinkler the W-Type 6 Sprinkler Wrench to the c mounting with Plate untile •its flange comes in inlet and cause leakage or impairment sprinkler wrench flats. contact the ceiling. TFP171 Page 4 of 12 *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector, special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 1 1/2' -- I / ff----_-_(12,7 mm) Ii ` 3 NOMINAL A— f 2-5/16' =,-� !A_ 2 MAKE-IN (58,7 mm) 1 2-1/4" 1-9/16" 4if • I 4 r (57,2 mm) I (39,7 mm) 1 ,..______ 5 3/4"NPT** WRENCH STYLE 30 or 40 FLATS RECESSED �_2-7/8"(73,0 mm)DIA. J' UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION ALL FINISHES EXCEPT POLY-STAINLESS WRENCH 3/4" ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated SURFACE 4 - Bulb 6 - Deflector* on Deflector. iiIMR -Irrrn Is AP' re----=---- / M (12,7 mm) i_ r 3 .E I1\ NOMINAL ��� �� 0 alla e__ 2 MAKE-IN 2-5/16" - "S ,� 7-1/4' �1� 'I _4 1-9/16" (57,2 mm) ■ (39,7 mm) .l i� 5 I STYLE 40 2-7/8"(73,0 mm)DIA. - RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION POLY-STAINLESS FINISH ONLY FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY4131)AND PENDENT(TY4231)SPRINKLERS 8.0 K-FACTOR,3/4 IN. NPT CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw 1 3 - Sealing 6 - Deflector * 111 a r-r r--TM Assembly 3 4 - Bulb 7/16" 2-1/4" (1N1,1 mm) g 1 (57,2 mm) 2 NOMINAL MAKE-IN * Temperature rating is 014 1 2-3/16" I 1-9/16" 4 indicated on Deflector. (55,6 mm) (39,7 mm) \ • --.-- 5 ** Pipe thread connections f per ISO 7-1 can be 6 * provided on special 1/2"NPT** f WRENCH request. FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY4831)AND PENDENT(TY4931)SPRINKLERS 8.0 K-FACTOR, 1/2 IN. NPT TFP171 Page 5 of 12 2-7/8"DIA. 2-7/8'DIA. 5/8x1/4' (73,0 mm) 3/4"(19,1 mm) 1/2t1/B" (73,0 mm) 1/2'(12,7 mm) (15,9±6,4 mm) 1/4°(6,4 mm) (12,7±3,2 mm) 1/4'(6,4 mm) 2-1/4" DIA. 2-1/4'DIA. / FACE OF (57,2 mm) MOUNTING / FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING / 1/8" / 1/8' ' G� 'I (3,2 mm) T11 fl �� (3,2 mm) MI --a..._r ___ li ja �� T ../4 MOUNTING I P f ', SURFACEMOUNTING I ■ SURFACEIr IF CLOSURE SERIES 1-5/16"(33,3 mm) CLOSURE SERIES 1-5/16'(33,3 mm) TY-FRB 13/16'(20,6 mm) TY-FRB 1-1/16'(27,0 mm) FIGURE 6 FIGURE 7 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 IN. NPT 2.8 K-FACTOR, 1/2 IN.NPT 2-7/8"DIA. _ _ 2-7/8'DIA. 5/8:1/4' (73,0 mm) 3/4'(19,1 mm) 1/2±1/8' (73,0 mm) 1/2'(12,7 mm) (15,9±6,4 mm) 2-1/4'DIA. 1/4"(6,4 mm) (12,7±3,2 mm) 2-1/4"DIA. 1/4'(6,4 mm) / FACE OF (57,2 mm) MOUNTING / FACE OF (57,2 mm) ~ MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" a (3,2 mm) T 1 1,i (3 m) 1 in i _ , - - f \ ,,, `-f i MOUNTING III MOUNTING SURFACE SURFACE .. -. SERIES 1-1/4"(31,8 mm) SERIES 1-1/4"(31,8 mm) CLOSURE TY-FRB 3/4"(19,1 mm) CLOSURE TY-FRB 1'(25,4 mm) FIGURE 8 FIGURE 9 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2/NCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 IN.NPT 4.2 K-FACTOR, 1/2 IN. NPT TFP171 Page 6 of 12 2-7/8"DIA. _ 2-7/8'DIA. 5/8±1/4' (73,0 mm) 3/4'(19,1 mm) 1/2t1/8" (73,0 mm) 1/2"(12,7 mm) (15,9±6,4 mm) 1/4"(6,4 mm) (12,7±3,2 mm) 1/4"(6,4 r____ 2-1/4'DIA. 2-1/4'DIA. mm) / FACE OF (57,2 mm) MOUNTING / FACE OF (57,2 mm) SPRINKLER MOUNTING PLATE SPRINKLER PLATE FITTING FITTING 1/8" / 1/8' ' l �i (3,2 mm) T �i P77'i ( mm) T jzi muoli[ \ � _ } II, !/ I II, \ '�, SURFACEO ��' MOUNTING SURFACE - , -� • CLOSURE SERIES 1-1/4'(31,8 mm) CLOSURE SERIES 1-1/4"(31,8 mm) TY-FRB 3/4'(19,1 mm) TY-FRB 1'(25,4 mm) FIGURE 10 FIGURE 11 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 IN.NPT 5.6 K-FACTOR, 1/2 IN.NPT 2-7/8'DIA. - 2-7/8"DIA.- _ 5/St1/4' (73,0 mm) 3/4"(19,1 mm) 1/2t1/8' (73,0 mm) 1/2"(12,7 mm) (15,9±6,4 mm) 2-1/4'DIA. 1/4"(6,4 mm) (12,7±3,2 mm) 2-1/4"DIA. 1/4'(6,4 mm) / FACE OF (57,2 mm) MOUNTING / FACE OF (57,2 mm) 1 MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING / 1/8" 1/8" (3,2 mm) / (3,2 mm) , /4 / j r PTA;. i, \ MOUNTING 10II MOUNTINGSURFACE SURFACE I CLOSURE SERIES 1-5/16'(33,3 mm) CLOSURE SERIES 1-5/16'(33,3 mm) TY-FRB 13/16'(20,6 mm) TY-FRB 1-1/16'(27,0 mm) FIGURE 12 FIGURE 13 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR,3/4 IN. NPT 8.0 K-FACTOR,3/4 IN. NPT WRENCH G RECESS WRENCH RECESS /��l (END'A"USED FOR ^ 1/2"NPT MODELS) WRENCH RECESS PUSH WRENCH (END'B"USED FOR IN TO ENSURE 3/4'NPT MODELS) ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 14 FIGURE 15 W-TYPE 6 SPRINKLER W-TYPE 7 RECESSED WRENCH SPRINKLER WRENCH TFP171 Page 7 of 12 Sprinkler Finish5 Bulb Liquid K-Factor Type Temperature Color Natural Chrome Plated Polyester= Brass 135°F(57°C) Orange 155°F(68°C) Red Pendent 175°F(79°C) Yellow (TY1231) 200°F(93°C) Green 286°F(141°C) Blue 1,2,3,4 135°F(57°C) Orange 155°F(68°C) Red Upright(TY1131) 175°F(79°C) Yellow 2.8 200°F(93°C) Green 1/2 in.NPT 286°F(141°C) Blue 135°F(57°C) Orange Recessed Pendent 155°F(68°C) Red (TY1231)a 175°F(79°C) Yellow Figure 6 200°F(93°C) Green 135°F(57°C) Orange 1,2,4 Recessed 155°F(68°C) Red Pendent (TY1231)b 175°F(79°C) Yellow Figure 7 200°F(93°C) Green NOTES a- Installed with Style 10(1/2 in.NPT)or Style 40(3/4 in.NPT)3/4 in.Total Adjustment Recessed Escutcheon,as applicable. b. Installed with Style 20(1/2 in.NPT)or Style 30(3/4 in.NPT)1/2 in.Total Adjustment Recessed Escutcheon,as applicable. c. Frame and Deflector only. 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the City of New York under MEA 354-01-E. 5. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed,the sprinklers are UL and C-UL Listed as corrosion-resistant sprinklers. TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 K-FACTOR SPRINKLERS TFP171 Page 8 of 12 Sprinkler Finish3 Bulb Liquid K-Factor Type Temperature Color Natural Chrome Plated Polyester° Brass 135°F(57°C) Orange 155°F(68°C) Red Pendent 175°F(79°C) Yellow (TY2231) 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange 155°F(68°C) Red Upright(TY2131) 175°F(79°C) Yellow 4.2 200°F(93°C) Green 1,2 1/2 in.NPT 286°F(141°C) Blue 135°F(57°C) Orange Recessed Pendent 155°F(68°C) Red (TY2231)e 175°F(79°C) Yellow Figure 8 200°F(93°C) Green 135°F(57°C) Orange Recessed Pendent 155°F(68°C) Red (TY2231)b 175°F(79°C) Yellow Figure 9 200°F(93°C) Green NOTES a- Installed with Style 10(1/2 in.NPT)or Style 40(3/4 in.NPT)3/4 in.Total Adjustment Recessed Escutcheon,as applicable. b. Installed with Style 20(1/2 in.NPT)or Style 30(3/4 in.NPT)1/2 in.Total Adjustment Recessed Escutcheon,as applicable. c. Frame and Deflector only. 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,far use in Canada(C-UL)as Quick Response Sprinklers. 3. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed,the sprinklers are UL and C-UL Listed es corrosion-resistant I sprinklers. TABLE B LABORATORY LISTINGS AND APPROVALS FOR 4.2 K-FACTOR SPRINKLERS TFP171 Page 9 of 12 • Sprinkler Finisha K-Factor Type Temperature Bulb Liquid Color Natural Chrome Polyester= Poly-Stainless= Lead Brass Plated Coated 135°F(57°C) Orange 155°F(68°C) Red Pendent 175°F(79°C) Yellow 1,2,3,4,5,6,7 1,2 1,2,3,5 (7 Y3231) 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange 155°F(68°C) Red Upright 175°F(79°C) Yellow 1,2,3,5,6 1,2 1,2,3,5 (TY3131) 200°F(93°C) Green 5.6 286°F(141°C) Blue 1/2in. ) Or ange (135°F 57°C Oran e Recessed 155°F(68°C) Red Pendent 175°F(79°C) Yellow 1,2,4,5 1,2 N/Ad (TY3231)a Figure 10 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange Recessed 155°F(68°C) Red Pendent (TY3231)b 175°F(79°C) Yellow 1,2,3,4,5 N/A N/A Figure 11 200°F(93°C) Green 286°F(141°C) Blue NOTES a. Installed with Style 10(1/2 In.NPT)or Style 40(3/4 in.NPT)3/4 in.Total Adjustment Recessed Escutcheon,as applicable. b. Installed with Style 20(1/2 in.NPT)or Style 30(3/4 in.NPT)1/2 in.Total Adjustment Recessed Escutcheon,as applicable. c. Frame and Deflector only. d. Not available(N/A). 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board(LPCB Ref.No.007k/04)as Quick Response Sprinklers.However,LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved(For details,contact Johnson Controls,Enschede,Netherlands,Tel.31-53-428-4444/Fan 31-53-428-3377.) 7. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/06)as Quick Response Sprinklers. 8. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers.Where Lead-Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. TABLE C LABORATORY LISTINGS AND APPROVALS FOR 5.6 K-FACTOR SPRINKLERS TFP171 Page 10 of 12 Sprinkler Finish8 K-Factor Type Temperature Bulb Liquid Color Natural Chrome polyesters Poly-Stainless Lead Brass Plated Coated 135°F(57°C) Orange 155°F(68°C) Red Pendent 175°F(79°C) Yellow (TY4231) 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange 1,2,3,4,5,6,7 1,2 1,2,5 155°F(68°C) Red Upright 175°F(79°C) Yellow (TY4131) 200°F(93°C) Green 8.0 286°F(141°C) Blue 3/4 in. NPT 135°F(57°C) Orange Recessed 155°F(68°C) Red Pendent 175°F(79°C) Yellow 1,2,5 1,2 N/Ad (TY4231)a Figure 12 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange Recessed 155°F(68°C) Red Pendent 175°F(79°C) Yellow 1,2,3,5 N/A N/A (TY4231)b Figure 13 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange 155°F(68°C) Red Pendent 175°F(79°C) Yellow (TY4931) 200°F(93°C) Green 8.0 286°F(141°C) Blue 1/2 in. 1,2,4,5,6 N/A 1,2,5 NPT 135°F(57°C) Orange 155°F(68°C) Red Upright 175°F(79°C) Yellow (TY4831) 200°F(93°C) Green 286°F(141°C) Blue NOTES a. Installed with Style 10(1/2 in.NPT)or Style 40(3/4 in.NPT)3/4 in.Total Adjustment Recessed Escutcheon,as applicable. b. Installed with Style 20(1/2 in.NPT)or Style 30(3/4 in.NPT)1/2 in.Total Adjustment Recessed Escutcheon,as applicable. c. Frame and Deflector only. d. Not available(N/A). 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc-,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board(LPCB Ref.No.007k/04)as Quick Response Sprinklers.However,LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved(For details,contact Johnson Controls,Enschede,Netherlands,Tel.31-53-428-4444/Fax 31-53-428-3377.) 7. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/06)as Quick Response Sprinklers. 8. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers.Where Lead-Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. TABLE D LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS TFP171 Page 11 of 12 Sprinkler Finish K-Factor Type Natural Chrome Brass Plated Polyester Lead Coated Pendent(TY1231) and 2.8 Upright(TY1131) 1/2 in. 175 psi(12,1 bar) N/A2 NPT Recessed Pendent(TY1231) Pendent(TY2231) and 4.2 Upright(TY2131) 1/2 in. 175 psi(12,1 bar) N/A NPT Recessed Pendent(TY2231) Pendent(TY3231) and 5.6 Upright(TY3131) 250 psi(17,2 bar) 1/2 in. or 175 psi(12,1 bar)1 NPT Recessed Pendent(TV3231) Pendent(TY4231) 175 psi and (12,1 bar) 8.0 Upright(TY4131) 3/4 in. 175 psi(12,1 bar) NPT Recessed N/A Pendent(TY4231) 8.0 Pendent(TY4931) 175 psi 1/2 in. and 175 psi(12,1 bar) (12,1 bar) NPT Upright(TY4831) NOTES 1. The maximum working pressure of 250 psi(17,2 bar(only applies to the Listing by Underwriters Laboratories Inc.(UL);the Listing by Underwriters Laboratories.Inc.for use in Canada(C-UL);and,the Approval by the City of New York. 2. Not available(N/A). TABLE E MAXIMUM WORKING PRESSURE Care and corrosive products of combustion,but tion Service in accordance with local have not operated,should be replaced requirements and/or national codes. Maintenance if they cannot be completely cleaned Care must be exercised to avoid by wiping the sprinkler with a cloth or damage to the sprinklers before, The TYCO Series TY-FRB 2.8,4.2,5.6, by brushing it with a soft bristle brush. during, and after installation. Sprin- and 8.0 K-factor Upright,Pendent,and Care must be taken to avoid damage klers damaged by dropping, striking, Recessed Pendent Sprinklers must be to the sprinklers before, during, and wrench twist/slippage,or the like,must maintained and serviced in accordance after installation. Sprinklers damaged be replaced.Also,replace any sprinkler with this section. Before closing a fire by dropping, striking, wrench twist/ that has a cracked bulb or that has lost protection system main control valve slippage,or the like,must be replaced. liquid from its bulb. For more informa- for maintenance work on the fire pro- Also, replace any sprinkler that has tion,see Installation section. tection system that it controls, obtain a cracked bulb or that has lost liquid Initial and frequent visual inspections of permission to shut down the affected from its bulb.For more information,see random samples are recommended for fire protection systems from the proper Installation section. corrosion-resistant sprinklers to verify authorities and notify all personnel who The owner is responsible for the the integrity of the corrosion-resis- may be affected by this action. inspection,testing,and maintenance of tant material of construction. There- Absence of the outer piece of an their fire protection system and devices after, annual inspections per NFPA 25 escutcheon, which is used to cover in compliance with this document, as should suffice. Inspections of corro- a clearance hole, can delay sprinkler well as with the applicable standards sion-resistant sprinklers are recom- operation in a fire situation. of the National Fire Protection Associ- mended at close range,instead of from Sprinklers which are found to be ation such as NFPA 25, in addition to the floor level per NFPA. Inspection at leaking or exhibiting visible signs of the standards of any other authorities close range can better determine the corrosion must be replaced. having jurisdiction.Contact the install- exact sprinkler condition and the long- ing contractor or sprinkler manufac- term integrity of the corrosion-resistant Automatic sprinklers must never be turer regarding any questions. material,which can be affected by the painted, plated, coated, or other- corrosive conditions present. wise altered after leaving the factory. Automatic sprinkler systems are rec- Modified sprinklers must be replaced. ommended to be inspected, tested, Sprinklers that have been exposed to and maintained by a qualified Inspec- TFP171 Page 12 of 12 P/N 57 - XXX - X - XXX I I SIN — TEMPERATURE SPRINKLER RATINGS FINISH 330 2.8K UPRIGHT(1/2 in.NPT) TY1131 135 135°F(57°C) 1 NATURAL BRASS 331 2.8K PENDENT(1/2 in.NPT) TY1231 POLY-STAINLESS GREY 155 155°F(68°C) 2 ALUMINUM(RAL9007)1 340 4.2K UPRIGHT(1/2 in.NPT) TY2131 POLYESTER 175 175°F(79°C) PURE WHITE 341 4.2K PENDENT(1/2 in.NPT) TY2231 3 POLYESTER(RAL9010)2 200 200°F(93°C) SIGNAL WHITE 370 5.6K UPRIGHT(1/2 in.NPT) TY3131 4 POLYESTER(RAL9003) 286 286°F(141°C) JET BLACK 371 5.6K PENDENT(1/2 in.NPT) TY3231 5 POLYESTER(RAL9005)3 390 8.0K UPRIGHT(3/4 in.NPT) TY4131 7 LEAD COATED 391 8.0K PENDENT(3/4 in.NPT) TY4231 9 CHROME PLATED 360 8.0K UPRIGHT(1/2 in.NPT) TY4831 NOTES 1. Available only on TY3131,TY3231,TY4131,and TY4231 2. Eastern Hemisphere sales only. 361 8.0K PENDENT(1/2 in.NPT) TY4931 3. Available in only 2.8K,4.2K,and 8.0K,155°F(68°C)and 200°F(93°C);requires longer lead time to manufacture. TABLE F • SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS • PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for www.tyco-fire.com. availability. When placing an order, indicate the full product name and Part Number(P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB(Specify SIN), (specify K-factor), (specify Pendent or Upright)Sprinkler(specify)temperature rating, (specify) finish or coating, P/N (specify from Table F) Recessed Escutcheon Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify°) finish, P/N (specify') •Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 1400 Ponnbrook Parkway,Lansdale,PA 19496)Telephone 91-215-362-0700 J r 02020 Johnsen Controls.All rlgnle reserved.All a...1.atlone and other lnlormation shown were current esofdocument revision date and ere subject to change wiFoul notice. Johnson ,' NATIONAL FIRE PPOTECTIIXJ ASSOCIATION eno NFPR ve 2gic,d00 endememf°'N°ticnel Fbe Rotecticn Pav°cleti°n: Controls TEFLON Is a r°pietwe0 ba0am0M°t OUPon[ 1 1{.1