Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
OFFICE COPY 1F COPY , �E4EIV Y 4,,E, SCOPE OF WORK FIRE ALARM EQUIPMENT SYMBOL LIST FEB 17 202! , j. BW aI NEW RELOC EXISTING SYMBOL DESCRIPTION PART # ROUGH-IN / NOTE MOUNTING HEIGHT e OF 1 y-IUP 1-{L. Y B .1 MODIFY AN EXISTING CONVENTIONAL FIRE ALARM SYSTEM WHICH INCLUDES THE s ADDITION OF A SMOKE DETECTOR, BOOSTER PANEL, HORN/STROBES, AND 1 FACP FIRE ALARM CONTROL PANEL EXISTING EXISTING EXISTING BUILDING DIVISION g 5 STROBES. 1 NACot FIRE ALARM REMOTE POWER SUPPLY POTTER SELF-CONTAINED SURFACE MOUNT ALIGN WITH OTHER EQUIPMENT PSN-64 16.75"H X 16.125"W X 3.5"D GENERAL NOTES 1 (� PHOTOELECTRIC SMOKE DETECTOR SYSTEM SENSOR 4" OCT OR SINGLE GANG CEILING MOUNT 'YY 4W-B 1. THE FIRE ALARM SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 3 C[n CEILING HORN/STROBE - WHITE SYSTEM SENSOR 4" SQUARE, 4" OCT, OR DOUBLE CEILING MOUNT 72 AND NFPA 70, ARTICLE 760, POWER LIMITED SYSTEMS. (NAC AND CANDELA NOTED AT DEVICE) PC2WL GANG BACK BOX I 2. FIRE ALARM WIRE INSTALLED IN VERTICAL RUNS AND PENETRATING MORE 11 Mil THAN ONE FLOOR SHALL BE RISER RATED. C CEILING STROBE - WHITE SYSTEM SENSOR 4" SQUARE, 4" OCT, OR DOUBLE a 3. FIRE ALARM WIRE RUN IN DUCTS OR PLENUMS SHALL BE PLENUM RATED. 3 ©° (NAC AND CANDELA NOTED AT DEVICE) SCWL GANG BACK BOX CEILING MOUNT 4. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. REVIEWED/APPROVED 5. A SYSTEM GROUND MUST BE PROVIDED FOR EARTH DETECTION AND NOTE: DEVICE COUNT IS FOR THIS SCOPE OF WORK ONLY. i LIGHTNING PROTECTION DEVICES. 6. DEDICATED BRANCH CIRCUIT(S) AND CONNECTIONS SHALL BE MECHANICALLY *****(N) - NEW DEVICE PROTECTED. (E) - EXISTING DEVICE 7. CIRCUIT DISCONNECT MEANS SHALL HAVE A RED MARKING, IDENTIFIED AS (R) - RELOCATED DEVICE BEN BREIT-4460LEA "FIRE ALARM CIRCUIT". 8. AUDIBLE ALARMS SHALL CONFORM TO SECTION 18.4.3 PUBLIC MODE (NFPA 72). 9. CENTRAL STATION MONITORING SHALL BE DOCUMENTED UPON COMPLETION OF THE PROJECT IN ACCORDANCE WITH SECTION 26.6.3 (NFPA 72). 10. A RECORD OF COMPLETION SHALL BE PROVIDED TO THE FIELD INSPECTOR 0 AT THE ACCEPTANCE TEST INSPECTION IN ACCORDANCE WITH FIRE ALARM RISER DIAGRAM (TYP.) p SECTION 14.6.2.4 (NFPA 72). ! 1 ICE /"�®P CITY OF TIGARD,_, W I-- REVIEWED FOR CODE COMPLIANCE Z q Approved: I Cl) OTC: ( I _ ° , Permit#: F Ps ao ZQ .. 0 0 0,13 FIST FLOOR - ELEC RM I " Address: 9 6"0 3'N,.r c. Jar? _ MC/PWR • Suite#�: V 2 SITE 18/4C FPLR A LIJ . a Br Date: ) FACP li (EXISTING) • r—n EXISTING FACP & AREAS OF O "+ NEW BOOSTER WORK NO-1 > 120VAC DEDICATED SW HAMPTON ST Oa C//- J Lr c BOOSTER TRIP I THIS EXISTING14:( ZCIRCUIT J N J■ TYPICAL NACRELOCATED3 uI14/2C FPLR FROM FACPNO-1. ON TRIP IN N1-1 EXISTING— EOLelkf!C EXISTING e e��� • MATCH EOL TBL N1-2 EOL 1kO _ a) co 0 ir i " ti ■ ho n 'y - POTTER DWG REV /DATE n RI ." n N1-3 SPARE EOL_e1k00 02/15/22 A k � A (NEW) if �� NAC01 N1-4 SPARE —& EOL.5e1k0 I J,� 120VAC DEDICATED TYPICAL NAC����•� • 14/2C FPLR DRAWN BY. NGM -.--- /, ,\ CHECKED BY: BJB 74.10 FILE NAME FA.dwg DRAWING#: FA-1 ORIG.SHEET SIZE'.11'x 17 #OF DWGS IN SET'. SHEET 1 OF 5 i i .kn. ocno S 2 K' NOTIFICATION CIRCUIT SCHEDULE ,,8 j VOLTAGE DROP CALCULATIONS ZONE SCHEDULE YoW CIRCUIT TOTAL WIRE WIRE VOLT VOLT ACCEPTED VOLT NEW BOOSTER NEW ADDRESS DEVICE LOCATION / AREA m g CKT # DEVICE LOCATION / AREA TRIP2 i ORIGIN AMPS DIST SIZE DROP AT EOL DROP DROP X ADDRESS Z- PHOTO FLR1 ELEC RM, AT PANELS NO-1 BOOSTER TRIP BOOSTER TRIP FACP 0.010 40 14 0.00 20.40 YES 0.01X THIS EXISTING ill1111 f N1-1 EXISTING EXISTING (MAX ASSUMED) NAC01 1.500 EXIST EXIST EXIST EXIST YES EXIST CIRCUIT RELOCATED N1-2 HORN/STROBES, STROBES FLR1 - SUITE 100 NAC01 0.427 265 14 0.69 19.71 YES 3.41% FROM FACP 1 N 1-3 SPARE SPARE NAC01 0.000 0 14 0.00 20.40 YES 0.00% NO-1. NEW T.I. N1-4 SPARE SPARE NACOI 0.000 0 14 0.00 20.40 YES 0.00% CIRCUIT o*****END-OF-UNE METHOD OF CALCULATION It I'-- 2:it 1111 BATTERY CALCULATIONS FACP (EXISTING) FLR1 ELEC RM p PART # DESCRIPTION QTY STANDBY STANDBY TOTAL ALARM ALARM TOTAL CI r. TBD MAIN CIRCUIT BOARD 1 0.1400 0.1400 0.5500 0.5500 4W-B PHOTOELECT ZONED HEAD 1 0.0001 0.0001 0.1300 0.1300 NEW W I- NO-1 NAC CKT#1 (BOOSTER TRIP) 1 0.0000 0.0000 0.0100 0.0100 STANDBY TOTAL 0.1401 ALARM TOTAL 0.6900 *CALCULATIONS BASED ON 24 HR STANDBY TIME & 5 MIN ALARM TIME* AMPS (A) X TIME (H) = AMP-HRS (AH) 20% DERATE • NEM STANDBY 0.1401 X 24 a 3.3612 - • ALARM 0.6900 X 0.0833 = 0.0575 - I TOTAL AH = 3.4187 4.1024 BATTERIES TO BE INSTALLED: (2)12V-7.0 AH ' 1 *****FOR CALCULATING PURPOSES, MAIN CIRCUIT BOARD CURRENTS SHOWN FOR SK-5208; FIRE ALARM OPERATIONAL MATRIX LIJ ACTUAL EXISTING FACP MODEL TO BE FIELD VERIFIED AND UPDATED ON AS-BUILT. SYSTEM OUTPUTS td O� y�P �pe� � V J BATTERY CALCULATIONS NAC01 NEW P�y�Poo`' �P\y�P G<,:,- y. �� Y POTTER P S N-6 4 (FLR1 ELEC RM) a Gc,-- �o`�� Ge 4o`� �oe�y ��yo��� a o M Q Q o FPO �y y y y, - ,z' _I N J PART # DESCRIPTION QTY STANDBY STANDBY TOTAL ALARM ALARM TOTAL GQ 4O p�' Q� p� ��Q �0.' �F' ��`' �v G�' FP 02 `F �QO { J� y�0 p�� �0�' F.� ° PSN-64 MAIN CIRCUIT BOARD 1 0.0750 0.0750 0.0750 0.0750 Q P Q O� O0 Q S `� y 4J Q fy ��'�Q`� Joy -\<; ��S��Sy ,P'4 P4' �G�,�GF, cr 0 Z = O Hi H�// AUX PWR: SYSTEM INPUTS P..N"Q� .0O 9 yJQ yJQ PGA PGC y�� y,� ��y NOTES: d 01 LL 1 0.0000 0.0000 0.0000 0.0000 O 2 ° Q EXIST/ SMOKE DEC. - NON ELEV • • • • _ I..L EXISTING ALARM • • • • N1-1 NAC CKT#1 (EXIST - MAX ASSUMED) 1 0.0000 0.0000 1.5000 1.5000 RELOC. DWG REV i DATE N1-2 NAC CKT#2 (NOTIFICATION) 1 0.0000 0.0000 0.4270 0.4270 EXISTING TROUBLE • • 0 02/15/22 N1-3 NAC CKT#3 (SPARE) 1 0.0000 0.0000 0.0000 0.0000 NEW EXISTING SUPERVISORY • • N1-4 NAC CKT#4 (SPARE) 1 0.0000 0.0000 0.0000 0.0000 STANDBY TOTAL 0.0750 ALARM TOTAL 2.0020 LOSS OF AC POWER AT FACP • • *CALCULATIONS BASED ON 24 HR STANDBY TIME & 5 MIN ALARM TIME* DRAWN BY OPEN CIRCUIT • • NGM AMPS (A) X TIME (H) = AMP-HRS (AH) 20% DERATE DISCONNECTION OF BATTERIES • • CHECKED BY'. STANDBY 0.0750 X 24 = 1.8000 - GROUND FAULT • • BJB ALARM 2.0020 X 0.0833 = 0.1668 - FILE NAME TOTAL AH = 1.9668 2.3602 FA.dwg PRESS SIGNAL SILENCE KEY • • BATTERIES TO BE INSTALLED: (2)12V-7.0 AH PRESS RESET KEY • DRAWINGS. FA-2 ORtG.SHEET SIZE.11'x 17" A OF OWGS IN SET'. SHEET 2 OF 5 o Ono 1 2 30_ Ps W0) go Y "s � . a 3 X X X 1P \ / Cit X / OO Z_ ELEC RM I I OFFICE (N) z4 105 (E) (N) I, FACP NACo1 /� /�./ 0 J r d la A W A NAC TO DEVICE '^ N1-2.1 v, OFFICE _ — 104 • / 2 7/ 1 r- /41 iOFFICE 0 U) 103 . V Ai //V X 4 42>JA / / CL. 0/3 LLI � a � J co CI Q III z = o LL t . I= LL DWG REV. DATE al ��� FLOOR 1 — ELEC RV 8' 16' 0 02/15/22 ` i;V SCALE: 1/8"=1'-0" KEYED PLAN NOTES: DAWN BY: NGM CHECKED BY.. 0 REPLACE EXISTING SMOKE DETECTOR WITH N . BJB FILE NAME: FA.dwg DRAWING#. FA-3 ORIG.SHEET SIZE:11"x 17" #OF DWGS IN SET'. SHEET 3 OF 5 • 888 1ifq S'o' 10 gR ww >3 w N Y 5Y 8 iJ 5 R n A n n 5 11 n R I e---Kt itillig /74/ OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE \ II 105 — _._r, 1 Q6' — 107 1.08 a-- , °-409 , 110 —111 • FROM s NAco1gig / I 1---- 0 t Ni-2.6 . -__-_.= 0 (1...:-.--.''\\ i EOL OFFICE 7sco11. 15CD OFFICE ,�, 112 104 � � c Er) .-� _ � c ►� (N) m - N15CD2 0 C �j(N) IT + rCD C o (N). — — N1-2.5 • 115 • II IA XORE FILE © X 15cD ® I I, .�...•� �, , I, O� ' CONFERENCE FILE BREAK I; X W 119 8 116 Jr)* OFFICE • H OFFICE ; 113 M • CO 103 o e (N)o , , OFFICE OFFICE © • N1-2.3 WORK N1-2 _ 11 114 15CD s 30C 0 101 ---Iz f • r 1 7 / U) s REOEPT�ON_ C� 100 Cr) I i / f, 1 // < co A . „ r_, Ca1eQ ZIO Hi (Low Et O mrn < — LL = (op LL DWG REV./DATE FLOOR 1 - SUITE 100 °__' 8' 16' 0 02/15/22 I4 glh 2► miur SCALE: 1/8"=1'-0" DRAWN BY: NGM GENERAL NOTES. CHECKED BY. BJB 1) EXISTING SMOKE DETECTORS WITHIN T.I. SPACE TO BE REMOVED; FILENAME: EXTEND SMOKE DETECTOR WIRING TO COMPLETE CIRCUIT FOR FA.dwg REMAINING EXISTING SMOKE DETECTORS DOWN LINE FROM THIS SPACE. DRAWING#: (FIELD VERIFY IF THESE ARE 4—WIRE DETECTORS 18/4C). FA-4 ORIG.SHEET SIZE:11°x iT #OF DWGS IN SET: SHEET 4 OF 5 i a z x,_o rn� 3 om m O o ci�Li w >In YIn 0 w nQ z a C z s (TYPICAL 18/2C) (TYPICAL 18/2C) PWR — PWR - FROM FACP 1 TO NEXORDEVICE PREVIOUS DEVICE TO FACP FOR O O OPTIONAL CLASS AI — IDC — IDC OR EOLR (TYPICAL 18/2C) (TYPICAL 18/2C) 0 O O IDC + .11 IDC + T OO C_�IV n ;ik, Do t °11 _� it 3111II U W 111 FROM NAC SOURCE § Imil 1climii n rare TO NEXT DEVICE \ PREVIODUS DEVICE �i �u =il��C� EOL(047 KII) `�®0 L rc NAC — "L" NACNAC4/2C) (TYPIC /2C) NAC + • "ii" Ni • o CD 0_ b 1 \„__ , _ _..;:s,,, Om 111 il:n a-n_- 0 (n S:-• CAUTION: DO NOT LOOP WIRE UNDER TERMINAL 1. SYSTEM SENSOR OeiCO CAUTION: BREAK WIRE RUN TO PROVIDE UNIVERSAL MOUNTING PLATE DO NOT LOOP WIRE UNDER SUPERVISION OF CONNECTIONS. TERMINALS. SW,P2W,SCW,PC2W U BREAK WIRE RUN TO PROVIDE BASE-4W-B 4WT-B SUPERVISION OF CONNECTIONS. L-SERIES:SWL,P2WL, (/) PHOTO SMOKE DETECTOR SCWL,PC2WL J W Z M HEAT DETECTOR a' 0 N SYSTEM SENSOR m a2 � OSMOKE/HEAT BASE NOTIFICATION p Z = o IA SCALE: NTS © SCALE: NTS rx O p awe rt O � LL = 2,cow o Li_ DWG REV.I DATE 0 02/15/22 DRAWN BY. NGM CHECKED BY. BJB FILE NAME FA.dwg DRAWING# FA-5 ()RIG.SHEET SIZE.11"x 17" #OF DWGS IN SET'. SHEET 5 OF 5